Professional Documents
Culture Documents
EXTENSIN LATACUNGA
CARRERA DE ING. EN ELECTRNICA E INSTRUMENTACIN
PERIODO: ABRIL - AGOSTO 2016 UNIDAD II
ELECTRNICA II NRC 1407
NOMBRE: LEMA NELSON
DISEOS
1.- Disear en base a comparadores las siguientes tipos de alarmas: Se dispone de una seal
acondicionada de 1 a 5V que representa el nivel de 20 cm a 6m de un tanque
H/H
Nivel 1= 5 m
Nivel 2= 5,8 m
51
6 0.2
= 0.6896
= 1 1
= 5 (0.6896)(6)
= 0.86
= ( ) +
1 = 5
= (5 0.6896) + 0.86
= 4.31
1 = 5.8
= (5.8 0.6896) + 0.86
= 4.86
VCC
VCC
12.0V
12.0V
U1
R1
1k
V1
R3
4.86V
330
VEE
741
R5
1k
0%
Key=A
-12.0V
LED2
VCC
12.0V
U2
V2
4.31V
330
4
741
VEE
-12.0V
H/L
Nivel 1 = 5,8 m
R4
Nivel 2= 0,40m
= ( ) +
1 = 5.8
= (5.8 0.6896) + 0.86
= 4.85
1 = 0.40
= (0.40 0.6896) + 0.86
= 1.13
LED1
VCC
VCC
12.0V
12.0V
U1
R1
1k
V1
R3
4.85V
330
VEE
741
R5
1k
100 %
Key=A
-12.0V
LED2
VCC
12.0V
1.13V
V2
U2
3
6
330
4
741
VEE
-12.0V
L/L
Nivel 1 = 1,2 m
R4
Nivel 2= 0,40m
= ( ) +
1 = 1.2
= (1.2 0.6896) + 0.86
= 1.68
1 = 0.40
= (0.40 0.6896) + 0.86
= 1.13
LED1
VCC
VCC
12.0V
1.68V
R1
1k
V1
12.0V
U1
R3
330
VEE
741
R5
1k
80 %
Key=A
-12.0V
LED2
VCC
12.0V
1.13V
V2
U2
3
6
R4
330
LED1
741
VEE
-12.0V
2.- Disear un circuito que indique el estado de una batera cuando el nivel sea superior a
12,9V y cuando sea inferior a 10,5V. Se utiliza una polarizacin de +- 12V
= 12.9
= 10.5
=
(12 0.2)
20
= 590
VCC
12.9V
R3
V1
18V
U1
R2
R4
330
741
4.7k
10 %
Key=A
LED1
VEE
1k
V1
12.0V
VCC
V2
-12.0V
1
10.5V
12.0V
U2
3
6
R1
330
LED2
741
VEE
-12.0V
3.- Disee un circuito que active una bomba en base al detector de nivel con histresis que
apague la bomba cuando el nivel sea superior a 10m y la encienda cuando sea inferior a
2m. Se dispone de una seal acondicionada de 1 a 5V que representa el nivel de 1m a 11
m de un tanque
= +
=
51
11 1
= 0.4
=
= 5 (0.4)(10)
=1
= +
1 = 10
= 0.4 10 + 1
= 5
1 = 2
= 0.4 2 + 1
= 1.8
= 5
= 1.8
=
= (5 1.8)
= .
+
12 + 12
3.2
= .
=
+
2
5 + 1.8
2
= .
1
= (1 + )
1
(1 + )
3.4
1
(1 +
)
7.5
1 = 1
=
= 7.5 (1 )
= .
VCC
12.0V
VCC
R5
1k
Vm
12.0V
12.0V
R3
16.4k
50 %
U1
3
6
R1
R7
1k
10k
Vref
U2
741
1k
Key=A
R4
10k
R6
741
LED1
R2
10k
3.0V
VEE
-12.0V
5.1
=
=
5.1
40
= .
= 2
= + +
=
Q1
2N3904
12 2 5.1
40
= .
R3
10
R2
2.2k
XMM1
VCC
12V
V1
D1
12V
U1
Q1
1N4733A
6
2
2N3906
R1
127.5
741
VEE
-12.0V
5.- Disear una alarma (con una sirena de 110V) que se active cuando el voltaje de
alimentacin sea superior a 100Vrms o cuando sea menor a 80Vrms.
110 5
100
100 5
=
110
= 4.54
110 5
80
80 5
=
110
= 3.63
VCC
VCC
D1
12.0V
U1
D3
T1
10k
741
1N3064
R1
10k
1N3064
1N3064
C1
220F
VEE
-12.0V
12.0V
R3
7.9k
D5
R5
220
12.0V
VCC
2N3904
U2
3
6
LS1
741
SONALERT
200Hz
VEE
R7
10k
Q2
R4
10k
1N3064
LED1
VCC
1
D4
D2
10:1
Q1
2N3904
R2
1N3064
12.0V
D6
1N3064
R6
220
-12.0V
LED2
V1
110Vrms
60Hz
0
D7
2N5571
R9
R8
10k
10k
Q3
2N3904
VCC
12.0V
6.- Disear una alarma que active una sirena de 110Vca (en caso incendio, basndose en la
deteccin de humo): utilizar elementos fotoelctricos (fotorresistencia, etc.).
=
2 +
1 + 2
122
1 + 2
VCC
12.0V
X2
LED1
VCC
12.0V
VCC
R1
Q2
D1
120V_100W
10k
12.0V
U1
1N4002
2N3906
10k
D2
2N5571
R4
R2
120Vrms
60Hz
0
10k
R3
10k
Q1
2N3906
V1
741
VEE
-12.0V
7.- Se dispone de dos generadores cuyos voltaje pueden variar desde 0 a 120Vrms. Disear
un circuito que encienda un led 1 (rojo) cuando V1 mayor a V2 y un led 2 (verde ) cuando
V2 sea mayor a V1 en 10 Vrms.
VCC
R3
1k
VCC
C1
470F
R5
20k
7
R2
1k
12.0V
LED1
741
22k
U2
VEE
-12.0V
1B4B42
4
R1
D1
T1
12.0V
V1
3
6
R8
C2
470F
U1
22k
U3
VEE
-12.0V
R4
1k
20k
R7
1k
V2
110 5
10
10 5
=
110
= 0.45
1B4B42
4
R6
D2
T2
VCC 12.0V
741
VEE
-12.0V
741
LED2