You are on page 1of 1

(Part-4)

SLAB Design as per BS-5400

References/Results

Materials Property
Specified minimum comp. strength of conc. at 28 days, fc

20

Mpa

Specified minimum yield strength of main reinf. steel, fy

460

Mpa

Specified minimum yield strength of sec. reinf. steel, fyv

460

Mpa

190000

Mpa

25000

Mpa

Table 3

12500

Mpa

Cl 4.3.2.1

Elastic modulus of reinf. steel, Es


Elastic modulus of concrete, Ec
Long-Term

Elastic modulus of concrete, Ec


Dia of bars , dbm

Layer 1
25

mm

No.of bars

Nos.

Spacing

mm

Dia of spacer bar

mm

Steel Area, As

mm2

Layer 2

Layer 3

150

150

150

3272.5

0.0

0.0

Section Dimension
Overall width of the section, b

1000

mm

Overall depth of the section, h

550

mm

50

mm

Minimum Reinf. Reqt. Check


0.15 % (bd)
As min =

0 Nos

No.of legs

a'

DESIGN FORCES
0.0

Spacing
fc

cc
fs

STRESS

STRAIN

Ultimate Limit State Axial, Pu

0 mm
300 mm

Dia of link

Stirrup Reinforcement Data

Service Limit State

kN

b
P (kN)

Remarks

M (kNm)

Ultimate Limit State Moment, Mu

300.0

kN-m

SLS1

Ultimate Limit State Shear, Vu

400.0

kN

SLS1

200.0 Perm Ld
0.0 Live Ld

kN-m

SLS3

100.0

0.0

Ultimate Limit State Torsion, Tu

Cl. 5.8.4

mm2

731.25

0.671 %
3272.49 mm
As provided =
0.15% of (bd) if fy=460Mpa, 0.25% of (bd) if fy=250Mpa

Clear cover to Ast, cc

OK

Main Reinforcement Data

= 0.5 x Ec

DESIGN FOR FLEXURE


Ultimate Limit State Check
Eff. depth of the section 'd'

STATUS

OK
mm

62.5

mm

500

mm2
mm

Cl 5.3.3.2

kN-m

Eq. 5

CG of reinforcements, dc
=

Reinf. steel area provided, Ast (flexure)


z = Min[0.95,(1-1.1*fy*Ast / (fcu*b*d) ) ]*d
Flexural resistance, Mr = Min

2772.74

+ AsL=Vu/(2*0.87fy)=

417.3

fy*Ast*z , 0.15*fcu*b*d^2)/1E6

STATUS

Allowable crack width


535 mm

a' =

35 mm

cnom =
s

ts

463

> Mu, OK

Serviceability Limit State Check


0.200 mm

Mod. ratio, n=Es/Ec long

NA, x=

176.03 mm

Moment of Inertia

acr =

76.276 mm

0.000750

0.00086 @ cnom

Wcr =
SLS3-fs =

0.000817

0.00005 (Eq.25)

SLS3-fc =

Cl 5.3.2.3
S

OK
15.20

71.26 Mpa

< (0.75fy) 345 Mpa OK

-2.65 Mpa

< (0.5fc) -10 Mpa OK

=
cnom

6.644E+09 mm4
< 0.2 mm OK

0.0089 mm

Cl 5.3.2.3

487.5

=
acr

ccr

Table 13, Eq. 24

DESIGN FOR SHEAR


Nominal Shear Resistance and Capacity

STATUS

488 mm

av =

2d / av =

OK

dia of link

Cl 5.3.3

0 mm

long. Spacing

(max=

487.5

300 mm

mm)

Cl 5.3.3.3

1.006

No. of legs

vc = 0.216*(pt)1/3*min(fc,40)1/3

0.513 Mpa

Asv prov

v c' =

1.033 Mpa

v = Vu / (bd)

0.821 Mpa

Eq. 8

299.9 mm2

if v > vc', Asv = (v-vc'+0.4)bsv/0.87fyv

140.4 mm2

Table 7

depth factor,

vc (2d/av) =

if v < vc', Asv = 0.4bsv/0.87fyv

0.0 mm2

v < vc', hence Asv reqd =

0 nos

Tables 9

0.0 mm2

Tables 8

if v < v c ', no min shear rft is reqd incase of slabs but reqd in beams.

Cl 5.4.4.1

DESIGN FOR TORSION


Torsional Shear Stress and Capacity
hmin (mm)=

550.0

hmax (mm)=

x1min (mm)=

450.0

y1max (mm)=

Asv

[Tusv/(1.6x1y1(0.87fyv))] =

STATUS
1000.0
900.0
0

Longitudinal Reinforcement due to Torsion


490.9 Asv (mm2) =
0.0
AsL (mm2) =
sL (mm) =

150.0

sv (mm) =

vt min =

mm2 v + vt =

300.0

0.3

Mpa

> vt

0.821

Mpa

< 3.35 Mpa

OK
0.0000

vt = 2Tu / [h2min ( hmax - ( hmin/3) ) ]

Mpa

Torsion Rft is not Required


Torsional Capacity is OK
STATUS

[AsL / sL]

[Asv*(fyv / fy) / sv ]

OK
3.28

Longitudinal Reinforcement provided is OK

> 0

OK

Cl 5.3.4
Eq. 9(a)
Table 10
Equation 10a, Table 10
Equation 11

You might also like