SMRT36
11.6 Kg
6
3
3 x 60 amps + 3 x 15 amps
3 x 75 amps
1 x 225 amps
SMRT36 + SMRT1
15.5 Kg
8
4
4 x 60 amps + 4 x 15 amps
4 x 75 amps
4 x 60 amps + 2 x 15 amps
1x 300 amps
CMC356
16.6 Kg
6
4
6 x 32 amps
3 x 64 amps
1 x 128 amps
CMC256
15.9 kg
6
4
6 x 12.5 amps
3 x 25 amps
1 x 75 amps
87 volts peak
87 volts peak
35 volts peak
15 volts peak
3 x 300 volts
1 x 600 volts + 1 x 300 volts
4 x 300 volts
2 x 600 volts (three phase open delta)
4 x 300 volts
1 x 600 volts
4 x 300 volts
1 x 600 volts
150 VA rms
( e.g 0.5 amps @ 300volts)
10 kHz
Yes
Yes4
100 watts ( 4 amps max )
Yes
Yes
150 VA rms
( e.g 0.5 amps @ 300volts)
10 kHz
Yes3
Yes
100 watts ( 4 amps max )
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
50 VA 1rms
(e.g 0.166 amps @300 volts)
3.1 kHz
No
No (optional extra)
50 watts ( 0.8 amps max)
No
No (each unit requires its own
software)
Yes
No
No
No
50 VA 2rms
(e.g 0.166 amps @300 volts)
3.1 kHz
No
No (optional extra)
50 watts ( 0.8 amps max)
No
Non (each unit requires its
own software)
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
No (factory only)
No
Yes (with optional CMcontrol)
No (factory only)
No
Yes (with optional CMcontrol)
weight
Total number current channels
Total number of voltage channels
Current output
Shock
Safety
Multiple unit can be controlled out of manual
control
Modular design
Manual control screen size
Brightness of manual control screen
Manual control can be held in hand while
testing
Several hundreds curves built-in for
manufacturer specific relay models in manual
control
Advanced auto pulsed ramping and binary
search pulse ramping in manual control
User can put his own logo via USB port of
manual controller
Can generate harmonics and wave sum in
manual control
Advanced distance relay capability in manual
control (e.g constant source impedance ,
binary search pulse ramping, etc)
Rio file import
Direct communication with SEL relays
Modbus communication
SS1 converter from Electron Cape and Aspen
Simulator programs
Simple Graphical language for producing
user specific automated test sequences
Can the relay setting automatically updated
during test sequence5
Automated test modules and database
management software
Yes
Yes
Yes
Yes
Yes
No
Yes
No
MIL-PRF-28800F, Military
Performance Specification:
5 to 500 Hz; 3 g acceleration; 10
minutes per axis
MIL-PRF-28800F, Military
Performance Specification: 30 gs
half sine pulse, 18 times
IEC 61010-1/-2
Yes
MIL-PRF-28800F, Military
Performance Specification:
5 to 500 Hz; 3 g acceleration; 10
minutes per axis
MIL-PRF-28800F, Military
Performance Specification: 30 gs half
sine pulse, 18 times
IEC 61010-1/-2
Yes
IEC 60068-2-6
10 to 150 Hz; 2 g acceleration
(20m/s2); 10 cycles per axis
IEC 60068-2-6
10 to 150 Hz; 2 g acceleration
(20m/s2); 10 cycles per axis
IEC 60068-2-27
15 gs, half sine pulse each
axis
IEC 61010-1
No
IEC 60068-2-27
15 gs, half sine pulse each
axis
IEC 61010-1
No
Yes
8.4
2
800 cd/m
Yes
Yes
8.4
2
800 cd/m
Yes
No
7
2
400 cd/m
No
No
7
2
400 cd/m
No
Yes
Yes
Unknown
Unknown
Yes
Yes
No
No
Yes
Yes
Unknown
Unknown
Yes
Yes
Unknown
Unknown
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
Yes
No
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
Yes
Yes