You are on page 1of 48

CENTRAL

W
NE

FAN CO.

ST
GE
AR
L
DS
LAN
G
EN

3890 MYSTIC VALLEY PARKWAY, MEDFORD, MA 02155


PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581

INDEX
ITEM

PAGE

BLOWERS
Double Inlet . . . . . . . . . . . . . . .47
Duct Blower . . . . . . . . . . . . . . .23
General Industrial
Material handling . . . . . .26, 27, 34, 35
General Purpose-utility . . . .28 thru 33
Pressure . . . . . . . . . . . . . . .27, 34
PVC-Corrosion Resistant . . .36, 37, 38
Supply or Make-Up (Roof Top) . . . .45
FANS

ALL ITEMS SHOWN IN THIS CATALOG ARE


CARRIED IN STOCK FOR IMMEDIATE DELIVERY
MANUFACTURERS OF

CENTRAL-AIRE

Exhaust Fans
FROM 8 TO 60 INCHES WITH SAFETY GUARDS

STOCKING DISTRIBUTOR FOR


ACME

FANTECH

PEERLESS

BROAN

FASCO

TJERNLUND

COOLAIR

LAU

VENT-AXIA

DELHI

NEW YORK

AND OTHERS

REPLACEMENT PARTS
Fan Blades

Electric Motors

Blower Wheels

Blower Shafts & Bearings

Belts

Pulleys

Attic . . . . . . . . . . . . . . . . . . .11
Bathroom . . . . . . . .15, 16, 18, 19, 20
Ceiling . . . . . . . . . . . . . . . . . .20
Darkroom . . . . . . . . . . . . . . . .21
Duct-In Line . . .16, 17, 20, 22, 23, 24, 25
Exhaust, prop. . . . . . . . . . .4, 5, 6, 7
Kitchen . . . . . . . . .16, 18, 19, 42, 43
Roof, axial up-blast . . . .BACK COVER
centrifugal up-blast . . . . .42, 43, 44
centrifugal . . . . . . . .16, 17, 40, 41
Sidewall, centrifugal . . . .16, 42, 43, 44
U.L., NFPA 96 APPROVED . . . . .42, 43
Window (Vent-Axia) . . . . . . . . . . .21
OTHER
Chemical resistance data . . . . . . .38
Curbs, roof . . . . . . . . . . . . .40, 46
Darkroom (Vent-Axia) . . . . . . . . .21
Draft inducers, duct boosters . . .12, 13
Make-up air fans . . . . . . . . . .14, 45
Motor & fan controls . . . . . . . . . .10
Relief-Supply vents . . . . . . . . . . .46
Shutters & louvers . . . . . . . . . .8, 9
Static vents . . . . . . . . . . . . . .9, 46
Special Motors . . . . . . . . . . . .5, 10
Thermostats . . . . . . . . . . . . . . .10
Vibration Isolators . . . . . . . . . . .39
General Ventilation Info . . . . . . . . . .2
General Motor Info . . . . . . . . . . . . .3

Fans & Blowers Repaired

CALL FOR PRICING.


Wholesale, distributor and OEM
discounts are quoted on request.
TERMS: Net 30 Days

We specialize in engineering practical solutions


to all ventilating problems.
Call direct to our engineering staff:
Phone: (781) 393-4456
1-800-937-4326
Fax: (781) 396-4581
www.centralfan.com

FREIGHT: F.O.B. Medford, MA


GUARANTEE: ONE YEAR
against defects in material or workmanship. We do not assume any responsibility
for incidental or consequential damages.
Details of terms and conditions; and limitations of warranty and liability available on
request.

ALL EQUIPMENT IS COMPLETELY ASSEMBLED AND TESTED BEFORE SHIPPING

PRICE $3.00
CATALOG #37

GENERAL INFORMATION
ASSUME: Air @ sea level (.075 lb/ft ), 70F, 50% RH, 29.92 in. Hg. This is STP condition.
3

Volume varies directly


New CFM = Old CFM x
as speed:
Horsepower varies as
cube of speed:

New HP = Old HP x

Pressure varies as
square of volume:

New SP = Old SP x

Horsepower varies as
cube of volume:

New HP = Old HP x

1750 to 3500 RPM = 8 x HP


1140 to 1750 RPM = 3.6 x HP
850 to 1140 RPM = 2.4 x HP

RPM
( New
Old RPM )
RPM
( New
Old RPM )
CFM
( New
Old CFM )
CFM
( New
Old CFM )

NOISE, SOUND RATINGS, & SONES

Typical Sound Levels


Sones

VENTILATION OF HOODS & BOOTHS


Process

Canopy Hoods
Slotted Sides

Steam Tanks

Canopy Hood

Threshold of feeling

110

15,000 CFM blower


elevated train; chipping hammer,
loud street noise

90

90*

Noisy factory; highway auto

38

80

Shouting; noisy gathering

150250
15002000

10

60

Average factory;
Average restaurant

75150

50

Average office

75125

40

Quiet home: average auditorium


Quiet conversation

30

Whisper

10

Sound proof room


Threshold of human audibility

75250
100150
200250

Paint Spraying

Open Front Booth

Furnaces

Canopy Hood
Enclosed Booth

Laboratory Booth

Source
500,000 CFM blower

120

Canopy Hood
Island Hood
Updraft

Plating Tanks

dB
140

150

Capture
Velocity
FPM

Type of Hood

Kitchen Ranges

100200
150250

Open Front Booth

75125

KITCHEN RANGE HOODS


1. CFM required is length x width (in feet) x velocity
as per above table.
(Depth of hood does not enter into calculations)
2. Hood should extend approximately 12 inches
beyond front and sides of range. Depth should
be two feet or more to accommodate bursts of
smoke.
3. Duct velocity can be 500 to 2000 FPM.
4. Two smaller ventilators are recommended in
place of one for more flexible operation and also
to provide ventilation should one fan fail.
Recommended ventilators for kitchen range
hoods are radial blade and backward curve
blowers.
5. U.L. classification YZHW and NFPA 96 provide
more detail.

STATIC PRESSURE LOSSES (in. H2O)


10'
.13
.31
.49

Duct Length
20'
.17
.35
.53

30'
.21
.39
.57

VEL.
FPM
1800
2000
2200
2400
2600
2800
3000
3200
3400
3600
3800
4000
4200

VP
In. Water
.202
.249
.302
.359
.421
.489
.561
.638
.721
.808
.900
.998
1.10

VEL.
FPM
4400
4600
4800
5000
5200
5400
5600
5800
6000
6200
6400
6600
6800

Recommended Ventilation Requirements


Max. occupant
Load, (persons
per 1000ft.2)

Classification

Auditorium

150

Classroom

50

CFM
per person
or area

Although fan noise is a function of a multitude of factors


the principal sources are (a) air turbulence (b) mechanical
and (c) vibration. Generally the quietest fan is also the most
mechanically efficient. Because a given fan location characteristics dictate audible noise, fan dBA cannot be guaranteed. However, relative noise levels of fans can be suitable
for considering one fan versus another.
The SONE number used in this catalog is a mathematically derived loudness (sound pressure) value as heard by
the human ear 5 feet from the inlet of the noise source in free
air (no ducts). Under these conditions, 10 SONES is twice as
loud as 5 SONES; or 20 SONES is 1/2 as loud as 40
SONES. Thus, SONE NUMBERS can be used as guides for
fan selection.
Where noise is a critical factor a more detailed, scientific analysis of the noise source and its surroundings would be
desirable. However, lined ducts, especially near the fan, provide ample sound attenuation for most clean air situations.
Also, to double the loudness (SONES) of a given fan, 13
more of the same fan must be added.

Training Shops

15
15
0.5 cfm/ft.2

Locker Room

Grease Filter
2" Mesh
Baffle
.25
.55
.25
.55
.25
.55

VP
In. Water
1.21
1.32
1.44
1.56
1.69
1.82
1.96
2.10
2.24
2.40
2.72
2.72
2.88

Education

*Max. permissible noise per 8 hr.-day

No. of
Elbows
0
1
2

VELOCITY PRESSURES
(At Std. Density .075#/Ft.3)

MOTOR RPM CHANGES & HP REQUIRED

BASIC FAN LAWS

30

20

Lounge

100

30

Dining Room

70

15

Restaurant

Offices
Conference Room

50

20

Office Space

20

Reception

60

20

Public Spaces
0.5 cfm/ft.2

Locker Rooms
Public Restrooms

75 cfm/closet
or urinal

Smoking Lounges

70

60

Specialty Shops
1.5/ft.2

Auto Service Stations


Beauty Salons

25

25
0.30 cfm/ft.2

Clothing Stores

1.0 cfm/ft.2

Pet Shops
Supermarkets

15

Sports & Facilities


Ball Rooms

100

25

Gymnasiums

30

20

Ice Rinks

0.5 cfm/ft.2

Swimming Pools

0.5 cfm/ft.2

Workrooms

ROOM SONES dBA CORRELATION

Darkrooms

0.5 cfm/ft.2

Duplicating, Printing

0.5 cfm/ft.2

SUPPLY OR MAKE-UP AIR

Unnecessary loss of summer air conditioning


or winter heating can be avoided if 80-90% of
exhaust air is supplied at or near the exhaust
hood. Make-up air appropriately introduced
into the exhaust hood need not be treated.

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

Loudness, Sones

Based on average duct velocity of 1700 FPM.

CONVEYING VELOCITIES
Material

Sound Level dBA

CATALOG #37
www.centralfan.com

Air & Smoke


Residential
Public Buildings
Industrial
Kitchen Hood
Fine Dry Dust
Coarse Dust, Sawdust
Large Particles, Moist Material

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

Duct Velocity
FPM

5001000
11001500
15002000
5002500
25003500
30004500
4500 & Up

MOTOR INFORMATION
Central Fan Co. uses motors that comply with EPACT (see page 10)
Follow all local electrical and safety codes, as well as the National
Electrical Code (NEC) and the Occupational Safety and Health Act
(OSHA).

TYPE OF MOTOR USUALLY REQUIRED


The great majority of small motors (12 HP & smaller) are 115 volts
single phase.

NEMA MOTOR FRAME DIMENSIONS-INCHES

Sizes of 34 to 112 are fairly divided between 208/230 volts single


phase and 208 to 550 volts 3 phase.
Sizes of 2 HP and larger are generally three phase as they are less
expensive and less troublesome than single phase motors.

1750
Frame
Size*

HP
3500
RPM

1750
RPM
1

20
12-13
1
2-112

8-12
3
4-2

D
Shaft
Height

42
48
56

U
Shaft
Dia.

8
2
5
8
7
8
7
8
118
118
138
138
158
158
178
178
1

112
3

1
2

143T
145T

5
5-712

3
5

182T
184T

10
15

712
10

213T
215T

20
25

15
20

254T
256T

30
40

25
30

284T
286T

V
2F
Shaft Parallel
Len. To Shaft

2E
Across
Shaft

BA
To First
Bolt Hole

312 slot
414 slot
478 slot

2116
212
234

258
3
312

118
112
178

134
234
3

312
312

214
214

4
5

512
512

214
214

412
412

234
234

412
512

712
712

234
234

514
514

338
338

512
7

812
812

312
312

614
614

4
4

814
10

10
10

414
414

7
7

412
412

912
11

11
11

434
434

Frames without T (preceding smaller size shaft). *3500 RPM motors are smaller.

APPROXIMATE MOTOR AMPS-1750 RPM *


HP
1

6
1
4
1
3
1
2
3
4

1 Phase
115V
230V

200V

3 Phase
230V
460V

575V

3.0
4.0
5.2
7.0

1.5
2.0
2.6
3.5

.9
1.1
1.6
2.3

.8
1.0
1.4
2.0

.40
.50
.70
1.0

1
112
2

10.4
13.0
19.0
24.0

5.2
6.5
9.5
12.0

3.2
4.3
5.7
7.1

2.8
3.8
5.0
6.2

1.4
1.9
2.5
3.1

1.1
1.5
2.0
2.5

3
5
712
10

34.0
52.0
76.0
90.0

17.0
26.0
38.0
45.0

10.8
16.0
24.0
30.0

9.4
14.0
21.0
26.0

4.7
7.0
11.5
13.0

3.8
5.6
8.4
10.0

46.0
57.0
76.0
85.0

40.0
50.0
66.0
74.0

20.0
25.0
33.0
38.0

16.0
20.0
26.0
30.0

15
20
25
30
For 3600 RPM motors multiply by .90
For 1140 RPM motors multiply by 1.1

.32
.40
.56
.80

*60 Hertz

Starting amps are approximately five times running amps. Fuses


must be large enough to carry this current. Delayed action fuses of only
25% above rated current may be substituted for better protection.

NEMA VOLTAGE VARIATIONS *


Nameplate
Rating

EFFECT OF VOLTAGE IMBALANCE


A small voltage imbalance between phases will cause an abnormal
temperature rise and abnormal current. For example, temperature &
current will rise 6-10 times the voltage difference. Notify the power company if voltage exceeds 1% (2 volts at 200v).

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

Suitable for line voltages

200/400

208,220 or 440

220/440

208,220,230 or 440,460

230/460

208,220,230,240 or 440,460,480

550 or 575

550 to 600

NEMA ratings are plus or minus 10% of nameplate.

*60 Hertz

Variations are suitable for fan or blower duty or other easy to start
applications only.

CATALOG #37
www.centralfan.com

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

CENTRAL-AIRE

Model K Exhaust Fans

HEAVY DUTY-GENERAL PURPOSE-DIRECT DRIVE-ENCLOSED MOTOR


Quiet operating general purpose fans for ventilation of most small areas where the usual low pressure conditions exist. For long duct runs use a centrifugal blower.
Suitable for use in restaurants, bars, clubs, laundries, bakeries, barns, stores, offices, industrial plants and
electronic equipment cooling.
Moderately priced and economical in operation-Built for years of dependable service-Broad deep pitch blades
for quiet, high air delivery-Attractive design, Gray green finish. Quality is equal or superior to higher priced
fans.

Thermally protected motors

Variable speed operation

Ball and sleeve bearings

Aluminum fan blades

OSHA type wire guards

125F max. temp. of operation

General purpose exhaust fans


for most small areas.

Available with reverse air flow (suction type) at no extra charge.


Suitable for operation to 125FOver 125F use a centrifugal blower

IMMEDIATE DELIVERY

MODEL K-SINGLE PHASE-115 VOLTS

HP

1 Speed
S

Variable
Speed
Wall
V
Shutter

115 v.
Amps

Speed
RPM

APPROXIMATE CFM
Static Pressure (inches H2O)
1
1
3
.1
8
4
8

*K80
*K10

1/80
1/40

X
X

X
X

A8
A10

.6
1.0

1550
1550

300
600

220
500

190
450

100
300

210

*K12
*K14

1/20

X
X

X
X

A12
A14

1.4
2.1

1550
1100

1000
1500

920
1300

880
1200

700
1000

450
720

1/6

X
X

X
.

A16

1860

1800

1560

1330

1/4

X
X

A18

2900

2660

2570

2340

2100

*KB20

1/4

A20

1160
1160
1160
1160
1160

2000

*K18

2.8
2.4
4.9
3.8
3.8

3600

3400

3330

3000

2700

*KB24

1/2

A24

6.5

1160

5800

5500

5200

4600

3700

*K16
*KB16
*KB18

1/15

*115/208-230v 1 (Ball Bearing)

(v) Variable speed includes Solid State Control

(X) Available Model

K12
K14

16
18

71/2
8

K16
KB16

20
20

K18
KB18

3/4

15
17

14
16

11
13

1
1

19
19

18
18

22
22

105/8
13

1
1

21
21

20
20

KB20

24

13

23

22

KB24

30

13

11/2

27

26

3/4

Ship
Wt.
7
12
15
20
28
30
29
32
35
51

See p.5 for 3 Exhaust fans

Exhaust
Air Flow

Reverse (suction) air flow requires


motorized shutter with #C10 switch
See page 8

*Fan and shutter mount over the hole


**Add 2" for suction fan configuration

For mounting fan in opening larger than fan panel. Price


includes mounting fan and shutter on plywood (34" outdoor type) of required size painted green. Models K12K24 require next size shutter.

Dimensions (inches)
Shutter Min. Hole
B**
C
D
Round*
5
0
111/4
8
51/2
0
13
10

A
101/2
13

MODEL K FAN AND SHUTTER ON PLYWOOD

ACCESSORIES:
Motorized shutter
Chemical resistant coating fan
Chemical resistant coating shutter

Model
No.
K8
K10

See Page 5 For Fans In This


Static Pressure Range

Model
No.

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

CATALOG #37
www.centralfan.com

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

CENTRAL-AIRE

Model P Exhaust Fans

SPECIAL PURPOSEDIRECT DRIVEHIGH PERFORMANCE


Features include extra high outputs at higher static pressures, larger sizes,
3 phase and explosion proof motors.

Sturdy construction for years of heavy duty service


Fans may be mounted in any position
Available with plywood panels for easy window installation
Open drip proof Ball Bearing motors-1 & 2 Speed
Totally enclosed Ball Bearing motors-1 & 2 Speed
Explosion proof fans include non-sparking blade and Class I
Group D, Class II Group F and G motors (See below caution)
Explosion proof motors are single speed only

All fans available with reverse air flow (suction type).


Suitable for use to 125F-Over 125F use a centrifugal blower.

For applications with


special requirements

SINGLE PHASE: 115 VOLTS

Model
No.
P10
P12
P14
P16A
P16B
P18A
P18B
P20A
P20B
P24A
P24B
P24C
P30B

HP
1

25
1
6
1
4
1
8
1
3
1
6
1
2
1
4
3
4
1
2
1
2
3
4
112

Fan with safety guard.

3 PHASE: 208, 230, 460 VOLTS

With Open Motor


With Enclosed Motor
Expl. Proof*
1 Phase
3 Phase
1 Phase
3 Phase 1 Phase 3 Phase
1 Speed 2 Speed 1 Speed 1 Speed 2 Speed 1 Speed 1 Speed 1 Speed
S
M
T
S
M
T
SX
TX

CFM
Static Pressure (inches water)
RPM

X(v)

1500

800

1750

1470

1350

1200

900

1750

2300

2100

1950

1600

1500

1400

X
X

X
X

X
X

X
X

1140
1750

2000
3150

1800
3050

1500
2800

1100
2600

800
2300

0
2000

X
X

X
X

X
X

X
X

1140
1750

2900
4300

2600
4000

2200
3800

1700
3400

1500
3100

1300
2800

X
X

X
X

X
X

X
X

X
X

1140
1750

3600
6000

3300
5800

3000
5600

2700
5300

2400
5000

2000
4700

X
X
X

X
X

X
X
X

X
X

800
1140
1140

4800
6000
8000

4600
5800
6900

3900
5500
6200

2900
4500
5700

1800
3800
5500

1000
3400
5000

1140

11000 10500 10000

9500

9000

8100

Caution:
Explosion Proof motors and non-sparking blades are usually
required in operating environments where explosive or ignitable
gases or dust are present. Proper motor selection requires full
understanding of U.L. and N.E.C. code designations. Article 500
(N.E.C.) covers the requirements for electrical equipment and
wiring. Equipment selection and wiring is a customer (user)
responsibility. Motors and impellers misapplied in hazardous environments are dangerous to personnel and property.

Examples of some hazardous materials:


Class I (Gases, Vapors)
Group AAcetylene.
Group BButadiene, ethylene oxide, hydrogen, propylene oxide.
Group CAcetaldehyde, cyclopropane, diethyl ether, ethylene,
isoprene.
Group DAcetone, acrylonitrile, ammonia, benzene, butane,
ethylene dichloride, gasoline, hexane, methane,
methanol, naphtha, propane, propylene, styrene,
toluene, vinyl acetate, vinyl chloride, xylene.
Note: A motor rated for Class I, Group D should not be used in the presence of Group A,B or C substances; and a Class II, Group F & G motor
should not be used with Group E substances.

300

(X) Available Model

Accessories:
Model
No.
P10
P12
P14
P16
P18
P20
P24
P30

Wall
Inlet Chem. Res.
Shutter Guard Coating*
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X

X
X
X
X

*Fan only. See page 8 for shutter


coating.

Opening
Nec.
(Round)

Approx.
Wt.
(Lbs.)

1
1

13
15
17
19

10
14
16
18

25
30
35
45

112
112
112
2

21
23
27
33

20
22
26
32

50
60
80
110

Dimensions (inches)

Class II (Combustibles Dusts)


Group EAluminum, magnesium and other metal dusts with similar characteristics.
Group FCarbon black, coke or coal dust.
Group GFlour, starch or grain dust.
Additionally, all hazardous location motors carry a T code which identifies
the maximum motor surface temp. (operating and burnout) which must be
correlated with the minimum ignition temp. of the hazardous substance.

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

400

X(v)

(v) Variable speed includes solid state control

480

See Pg.10 for 2 speed 3, 208 1 and switches


*Incl. Non-sparking blade

700

Model
No.

P10
P12
P14
P16

13
16
18
20

10
11
12
13

P18
P20
P24
P30

22
24
30
36

13
13
14
15

Model number indicates fan blade diameter.

CATALOG #37
www.centralfan.com

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

CENTRAL-AIRE

Model R Exhaust Fans

ALL PURPOSEBELT DRIVERUGGED WELDED CONSTRUCTION


All Purpose-Belt Drive-Rugged Welded Construction
An all purpose high performance fan suitable for ventilation of most large areas requiring dependable ventilation.
Large selection of speeds and motors to choose from to cover a wide range of commercial and industrial requirements.
Recommended for ventilation of stores, halls, offices, restaurants, garages, barns, air conditioning equipment
rooms and all types of industrial buildings.
Moderately priced yet built for years of dependable service.

WARNING:
OSHA guards recommended
when installing fan within
7' of floor.
SEE page 7

IMPORTANT FEATURES

All purpose exhaust fans


for most large areas.

SPECIFY EXHAUST
OR SUCTION

Quiet operation-High air output-Slow speed.


Flexible choice of speeds and motors available.
Easy and economical motor replacement if necessary.
Ball Bearing throughout-motor & fan.
Generously sized belt drive for trouble free operation.
Heavy duty propellers, designed for low static and high air volumeeither exhaust or suction.
Not designed for motor reversing operations.

WITH OPEN MOTOR-WHEN ORDERING: SPECIFY LINE VOLTAGE AND PHASE

Model

R24

R30

R36

B
C*
D
E
F
C
D*
E
F
G
D
E*
F
G
H

Single Phase**
Three Phase
Approx. Tip
1 Speed 2 Speed 1 Speed 2 Speed Wall
Fan Speed Noise
S
M
T
R
Shutter RPM
FPM Rating

HP
1

4
1
3
1
2
3
4
1
1

3
1
2
3
4
1
112
1

2
4

1
112
2
3

X
X
X
X
X

X
X
X
X
X

X
X
X
X
X

X
X
X

X
X
X
X
X

X
X
X
X

X
X
X
X
X

X
X
X
X

X
X
X
X
X

X
X
X

X
X
X
X
X

X
X
X
X
X

X
X

X
X
X
X
X

X
X
X
X
X

R42

E
F*
G
H
J

1
112
2
3

X
X
X
X
X

R48

F
G*
H
J
K

1
112
2
3
5

X
X
X
X

X
X
X
X
X

X
X
X
X
X

R54

G
H*
J
K

112
2
3
5

X
X
X

X
X
X
X

X
X
X
X

R60

H
J*
K
L

2
3
5
712

X
X

X
X
X
X

X
X
X
X

*Recommended for most commercial and industrial applications.


See page 10 for special motors. (X) Available models
**Single Phase 120v or 230v. See p.10 for 208v 1.

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

540
600
690
750
850

3390
3770
4335
4710
5300

A
A
B
C
D

4800
5300
6000
7000
8000

3900
4600
5400
6400
7500

3100
4300
5600
6800

2800
3800
5400

3100
4300

3600

460
480
530
570
640

3770
4080
4710
5100
5890

A
A
B
C
D

7000
8000
9000
10000
12000

5700
6900
8100
9200
11300

4600
6500
8000
10300

4200
5400
8200

4400
6500

5300

480
600
620
700
760

3770
4712
5655
6597
7540

A
B
B
C
D

10000
12000
14000
16000
18000

8200
10300
12600
14700
17000

6900
10100 6400
12800 8600
15500 12200

7100
9800

7900

A42

400
480
520
600
670

3848
4398
5497
6322
7147

A
B
B
C
D

16000
18000
20000
22000
25000

13100
15400
18000
20200
23500

10400
14400 9200
17600 11900 9700
21500 17000 13500 11000

A48

400
460
500
580
650

3770
4712
5684
6597
8167

A
B
B
C
D

21000
24000
26000
30000
36000

17200
20600
23400
27600
33800

13900
16200 13200
24000 16200 13200
30900 24500 19500 16000

A54

300
350
420
500

4241
4948
5655
6361

A
B
B
C

27000
30000
35000
42000

23200
27000
32200
39500

15600
21600 13800
28000 18900 15400
36000 28500 22000 18500

A60

270
300
375
470

4271
4712
5890
6744

A
B
B
C

34000
41000
48000
55000

30600
37000
45000
53000

24500
32800
41000
49000

A24

A30

A36

See page 10 for motor controls.

18600
22100 18000
34000 27000 22000
44000 38000 33000

NOISE RATING
Applications

Dimensions & Accessories:


See next page

CFM
Static Pressure (inches water)

CATALOG #37
www.centralfan.com

Residences, Churches, Schools, Libraries


Stores, Offices, Hall, Restaurants
Laundries, Bakeries, Bowling Alleys
Very noisy locations
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581

Rating
A
A or B
B or C
B,C, D

CENTRAL-AIRE

Model R Exhaust Fans

DIMENSIONS (INCHES)
Panel Approx.
Sq.
Depth
A
B*

Model
No.

Shutter Opening Min.


(Sq.) Req. (Rd.) Wall
D
O*
W**

Approx.
Wt.
Lb.

24
30
36
42

30
36
42
48

14
15
16
17

112
2
214
212

27
33
39
45

26
32
38
44

6
7
8
10

70-100
90-120
100-140
130-150

R 48
R 54
R 60

54
60
66

18
27
27

214
2
2

51
57
63

50
56
62

12
14
16

160-200
270-320
390-470

R
R
R
R

Model number indicates fan blade diameter.


*Allows venturi penetration of wall.
**Shutter blades will flutter if fan blade is too close to shutter.
W dimension must be increased for higher RPM or where quieter operation is desired.

OSHA COMPLIANT FAN GUARD


20 gauge galvanized steel panels, expanded metal grille. Bolt together guards
shipped unassembled (mounting hardware included). Heavy gauge panels bolt
together to form housing. Grille fastens to housing with screws supplied. Guard
can be mounted directly to fan frame or wall.

GUARD DIMENSIONS
A

Depth
C

Ship
Wt.

24
30
36
42

30
36
42
48

30
36
42
48

20
20
30
30

35
40
60
90

R 48
R 54
R 60

54
60
66

54
60
66

32
34
37

120
200
256

Model
No.
R
R
R
R

ACCESSORIES

Model
R
R
R
R

#
*
**

Inlet
Guard

Motorized
Shutters
115 or
230 V #440V

Chem. Resis. Coating


Fan and Automatic
Motor
Shutter

Motor*
Two**
Disconnect
Speed
Switch
Controls

24
30
36
42

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

R 48
R 54
R 60

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

440V uses 115/230V motor with a transformer.


Mounted to fan panel.
All without overload protection (limited availability for larger HPs see page 10).

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

CATALOG #37
www.centralfan.com

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

Model A Aluminum Wall Shutters


AUTOMATIC-MOTORIZED-CHAIN OPERATED
EXTRA HEAVY DUTY FRAMES FOR DIMENSIONAL STABILITY

Model A

Model
No.

Frame is .080 x 1.50 extruded aluminum with mill finish & welded corners.

Aluminum blades are 26 gauge with 20 gauge galvanized reinforcement strip across
top of blade & felt seal on leading edge of blade for quiet closing.

Stainless steel bearings and pivot pins for extended life.

POSITIVE ACTION MOTORIZED SHUTTERS: Motor is securely bolted to frame.


Special linkage operates center rod for uniform and positive operation.

CHAIN OPERATED: For manual operation; coil spring positive closing.

Nominal
Dim. (Sq.)
I.D. O.D.
A
B

2600
FPM
Max
CFM

Automatic
Motorized**
Gravity 115 or
Operated 230 V.
440

Model A Motorized

Chain
Operated

A
A
A
A

8*
10
12
14

8
10
12
14

11
13
15
17

1150
1800
2600
3500

X
X
X
X

.
X
X
X

.
X
X
X

X
X
X
X

A
A
A
A
A

16
18
20
24
30

16
18
20
24
30

19
21
23
27
33

4600
5850
7200
10400
16250

X
X
X
X
X

X
X
X
X
X

X
X
X
X
X

X
X
X
X
X

A
A
A
A
A

36
42
48
54
60

36
42
48
54
60

39
45
51
57
63

23400
31850
41600
52650
65000

X
X
X
X
X

X
X
X
X
X

X
X
X
X
X

X
X
X
X
X

SIDE VIEW
AIR FLOW

FRONT VIEW

5
*Steel frame with 1 8 flange.this size only

**Also available as power close, fail open (for


elevator machine rooms). Maximum UPS ship size is A36, B36 440V uses 115/230V motor
with a transformer
(X) Available models

Also available

DELAY SWITCH.MOUNTED ON SHUTTER

PROTECTIVE COATING

Motorized shutter will not open against substantial fan induced air flow. Delay switch should be
used to allow shutter to open fully before fan becomes operational. For 1 or 3 applications.
Delay Switch Model C10

Air Dry PVC Coating


.
Models A,B or BS

Model B Roof Fan Shutters


Flange-less steel frame-Felted aluminum blades-Can be used inside ducts. Opens in direction of air flow. Curb drop in type to
prevent backdraft when roof fan is not running. Sized to fit onto shelf of roof curb.

Model
No.

Nominal To 1500
O.D.
FPM Automatic
+0 - 18
Max.
Gravity
(Square) CFM
Operated

B
B
B
B
B

9
10
12
14
15

9
10
12
14
15

800
900
1300
1800
2100

X
X
X
X
X

X
X
X
X
X

X
X
X
X
X

B
B
B
B
B
B

16
18
20
22
24
28

16
18
20
22
24
28

2400
3100
3900
4800
5700
7800

X
X
X
X
X
X

X
X
X
X
X
X

X
X
X
X
X
X

B
B
B
B
B

30
32
36
39
42

30
32
36
39
42

9000
10000
13000
15000
17900

X
X
X
X
X

X
X
X
X
X

X
X
X
X
X

20
24
28
3212
3912

3100
4800
7000
9000
14000

X
X
X
X
X

BS
BS
BS
BS
BS

18
22
26
30
37

(X) Available models

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

Motorized
115 or #440V
230 V.

CATALOG #37
www.centralfan.com

#440V use 115/230V motor with a transformer

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

STATIONARY LOUVERS
Extruded .081 aluminum alloy construction.
Drainable blades-Falling water is drained to the side, removing cascading
water droplets from the air stream.
Mitered corners for dimensional stability.
Expanded 12" screen interior mounted. (insect screen optional)
112" flange is standard (channel frame optional).
Standard mill finish (optional Baked Enamel, Kynar, Anodized).
4" deep frame (6" Available).

IN STOCK SIZES

Stock
No.
S61

Nominal
Size* (in.)
12 x 12

Free Area (ft2)


0.23

Intake
CFM**
250

Ship
Wt. Lbs.
9

S62

14 x 14

0.38

400

10

S63

16 x 16

0.53

570

12

S64

18 x 18

0.78

850

14

S66

24 x 24

1.64

1750

21

S67

30 x 30

2.81

3000

29

S68

36 x 36

4.31

4600

40

*Suggested hole size (Louver dimension

**max. cfm before

w/o flange 14" less)


Max. single section 96" x 96". For larger sizes
use multiple sections.
Other sizes and shapes, etc. Special Order

water penetration
begins (1075 FPM).

CUSTOM ORDER LOUVERS AND DAMPERS


COMBINATION LOUVERS
Combination louvers integrate stationary blade and adjustable
blade construction in a single frame.
All the features and options of stationary models.
Blade edge gaskets.

BACKDRAFT DAMPERS
.064 aluminum construction.
Nylon bearings with Delrin pivot pins.
PVC foam gasketed blades.
Full 90 degree operation.

Rear mounted exposed linkage.

Flange and channel models available.

Wide variety of manual, electric or pneumatic operators.


Custom made to order maximum single size is 72" W x 96" H.
For larger sizes use multiple sections.

Intake and exhaust installations.


Vertical and horizontal models.
Custom made to order maximum single size is
36" W x 72" H.
For larger sizes use multiple sections.

CONTROL DAMPERS
Available in 13 ga. aluminum and 16 ga. steel
construction.
Opposed blade and Parallel blade models.
PVC foam gasketed blades.
Low leakage models with stainless steel jam seals.
Concealed end linkage.
Wide variety of manual, electric or pneumatic
operators and operator accessories.
Custom made to order.

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

CATALOG #37
www.centralfan.com

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

Motor Controls for Fans & Blowers


SINGLE SPEED CONTROLS
Manual
Type

Cat.
No.

Phase

Dimensions
Nema
Size

Poles

Fig.

Without
Overload

6810-G
7810-GD

1
3

2
712

10

1
1

2
3

A
A

4
4

214
214

212
212

Exp. Prf.

6810-E

00

634

312

434

434

Exp. Prf.

Fig. A

Maximum HP
208
460
115V
230
550

7810-E

7 2

10

00

6 4

3 2

TWO SPEED CONTROLS


Without
Overload
Protection

27956
2512KG22
C61
C62
27940

3 (2 Wdg.)
3 (2 Wdg.)
1
1
1

1/3
3/4
1

1/2
7 1/2
1/3
3/4
1

10
-

00
1
00
00
00

3
3
1
2
2

C
A
C
C
C

4 1/4
4 1/4
4 1/4
4 1/4
4 1/4

2 1/8
4 5/8
2 1/8
2 1/8
2 3/4

2 3/8
2 3/8
2
2 3/8
2 1/2

JV2
JV5

3 (1 Wdg.)
3 (1 Wdg.)

3
5

3
5

1
1

3
3

D
D

8
8

3
3

3 1/2
3 1/2

SOLID STATE VARIABLE


CONTROL

LINE VOLTAGE THERMOSTATS (1)

Fig. B

Max HP
Max Motor Amps
Temp F
115V 230V 115V
230V Range
Diff

Model

Type

C73
C74
C74A
C76A
C77*

Heat/Cooling
Cooling (Attic)
Cooling (Attic)
Heat/Cooling
Heat/Cooling

4
3
4

112
112

112

13.8
13.8
4.4
13.8
16

10
10

10
8

50-90
90-130
50-120
40-110
30-110

Switch
Type

2
SPST
15
SPST
15
SPST
3
SPDT
3 SPDT/SPDT

(Shaded Pole or Perm. Cap. Motors)


SINGLE PHASE
Model No.
C64
C65
C75
277V
C64-3
C65-3

*2-stage (2speed or 2 motors).

Fig. C

MOTOR DISCONNECT SWITCHES


HP
3

1-2
3
5
712-10

Fig. D

Single Phase
1 Sp. 2 Sp.
X
X
X
X
X

460V-550V only

Three Phase
1 Sp. 2 Sp.
X
X
X
X
X
X
X
X
X*

Volts
Amps
120
6
120
10
230
6
277
6
3-wire control
for constant 115v

INPUT POWER SAVING (RPM CONTROL)


A significant reduction in energy consumption is realized when centrifugal fan
speeds are reduced only slightly. In applications where maximum demand volume
is not constant (VAV Systems), RPM control with inverters (variable frequency)
could result in considerable reduction in power consumption. (Fan power demand
varies with RPM3)
Analysis of each fan application will determine the suitability of various volume
control methods (Dampers, inlet vanes & inverters). Inverters available special order.

(X) Available

The Energy Policy Act (EPAct) took effect October 24, 1997. This law mandates efficiency standards for general purpose, three phase, 2,4 and 6 pole
AC motors from 1 to 200 horsepower manufactured for sale in the U.S. Many motors such as explosion proof, two speed, TEFC, single phase and others, are excluded. Central Fan will provide motors that comply with the mandate when applicable.

SPECIAL MOTORS
Two Speed
2 Winding
1 Wndg
1750/1140
1800/900

Special Enclosures
Enclosed
Expl. Proof
1750 or 3450
1750 or 3450

208v 1 ODP

277V
1 ODP

RPM

RPM

*High
Efficiency

1
ODP
X
X

3
ODP

3
ODP

1
X
X

1
X
X

1750

3450

1725/1140

1750

1750

3450

X
X

X
X

X
X

X
X

X
X

X
X

X
X

X
X

X
X

X
X

X
X

1
112

X
X

X
X

X
X

X
X

X
X

X
X

X
X

X
X

X
X

X
X

X
X

2
3

X
X

X
X

X
X

X
X

X
X

X
X

X
X

5
712

X
X

X
X

X
X

X
X

X
X

HP
1

4
1
3
1
2
3
4

Note: 2-sp. XP motors not available.


See page 5 for expl. proof motor description.
* High efficiency motors suitable for use with VFD controls.
Note: All single phase ODP motors are not readily available marked for 208v 1. (115v is std.) (X) Available

10

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

CATALOG #37
www.centralfan.com

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

Residential Attic Fans


IMPORTANT FEATURES

Fan size selected should be capable of changing the entire volume of a


home in approximately two minutes. (Do not include the attic space unless
used for living .)

Slow speed belt driven for quietness


Ball bearing fan & motor-permanently lubricated
Compact construction with no unnecessary weight

An average size home will require a 30 inch fan.


Operation with a time switch is recommended. Turn fan on for hours desired
and forget it. Fan shuts off automatically.

Two types to choose from


Single phase-115 Volts ODP

Time switch installs in single gang switch box. Two speed operation affords
additional flexibility. Two speed & timer switches in double gang box.

Atlas Wall Fans


Recommended for their quietness of operation. For attic window or wall installation in
homes with reasonably air tight attics. Two smaller fans may be used if space is not available for one large fan.
Fan installs against wall opening on the inside and the shutters on the outside. Shutters
close automatically when the fan stops, keeping rain, wind and insects out.
Ceiling opening may be used as an access to the attic if ceiling shutters are placed on
the attic floor unfastened.

FAN

Model
No.
R24B
R30C
R36D
R42E

HP

White
Motorized Two
1 Speed 2 Speed
Wall
Ceiling
Speed
S
M
Shutter Shutter* Switch

4
3
1
2
3
4

X
X
X
X

X
X
X
X

A24
A30
A36
A42

EM24
EM30
EM36
EM42

X
X
X
X

DIMENSIONS (inches)
Fan
RPM

Air
CFM

Volume
of home
(Cubic ft.)

540
480
400
350

4800
7000
10000
16000

9600
14000
20000
32000

Fan
O.D. Sq.
30
36
42
48

Fan
Wall Wall Shutter
Depth Opening Rd. O.D. Sq.
14
15
16
17

26
32
38
44

27
33
39
45

Wt.
Lb.
60
70
90
110

*Motorized ceiling shutters are recommended if attic space is not air tight. Ceiling shutter dimensions are shown with Lay Down Fans. See page 7 for safety guards.
(X) Available models
Twelve hour timer switch available.

Atlas Lay-Down Fans


Easily installed-Simply cut hole in attic floor over hallway, Lay Down fan over this
opening on top of sound absorbing plastic strips and install shutter on ceiling below.
Sufficient vent area must be provided to let the hot air out of the attic through
louvers on wall, vents under the eaves, or in ridge.
Aluminum shutters fit flush with ceiling.
Fan may be pulled up through ceiling opening.
Most economical installation is ceiling shutter not motorized.
FAN

Model
No.
RS24B
RS30B
RS36C
RS42C

HP

Gravity
White
Two
1 Speed 2 Speed Ceiling
Speed
S
M
Shutter* Switch

4
4
1
3
1
3
1

See page 7 for safety guards.

X
X
X
X

X
X
X
X

E24
E30
E36
E42

*Baked white enamel

Dimensions (Inches)
Fan
RPM
500
400
340
280

X
X
X
X

(X) Available models

Air
CFM

Volume
of home
(Cubic Ft.)

Fan
O.D.(Sq.)

Fan
Height

9000
13000
18000
24000

30
36
42
48

14
15
16
17

4500
6500
9000
12000

Min. Vent
Shutter
Ceiling Area Req.
Flange O.D. Opening (Sq. in.)
26
32
38
44

24
30
36
42

884
1248
1728
2300

Fan
Wt.
Lb.
60
70
80
90

Twelve hour timer switch available.

Central-Aire Attic Cooling Fans


FOR COOLING HOT ATTICS & REDUCING AIR CONDITIONING COSTS
For easy to install sidewall installation.
Complete with shutter and adjustable thermostat.

Safety inlet guard.


Lifetime lubricated quiet motors.

Model

Blade
Dia.

Max. attic
floor area
Sq. Feet*

CFM

HP

K12AF
K14AF
K16AF

12"
14"
16"

1000
1500
2000

1000
1500
2000

20
1
15
1
8

Amp. RPM
1.4
2.1
2.4

Recommended setting for thermostat is 100 Degrees. (Shuts off at approx. 90)
*1 CFM per ft2 of attic for summer venting.
Recommended air intake area is exhaust CFM 300 = req. ft2

**
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581

CATALOG #37
www.centralfan.com

1500
1100
1100

Fan
O.D.
Opening
(Sq.) Nec. (Sq.)**
16"
18"
20"

13"
15"
17"

Ship
Wt.
Lb.
16
20
28

Optional humidistat
UL
120V 7.5 amps (max.)
adjustable setting Model PH

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

11

DRAFT INDUCERS
FOR VERTICAL VENTING

[See page 14 for make-up (combustion) air devices.]

DRAFT INDUCER SELECTION TABLE


TJERNLUND AUTO-DRAFT INDUCERS
assure positive draft when restricted boilers and furnaces, poor chimneys or negative pressures in building prevent proper
exhaust of combustion gas. The Venturi
action of Tjernlund Auto-Draft Inducers
starts air moving up the stack instantly,
keeps it moving smoothly. These units are
adaptable to all heating systems. They are
quick and easy to install and completely
automatic in operation. Tjernlund's unique
design and careful construction makes
them trouble-free and reduces maintenance to a minimum. The Vari-Draft
Control permits adjustment to the individual
job requirement.

Pipe
Size
In.

Heater
270F
BTU Flue Gas
Input S.P. CFM

Model
No.

DJ-3

D-3

NOTE:
1. Inputs shown above are believed
to be maximum capacities for
inducers, when mounted on pipe
sizes shown for ordinary jobs
where a moderate amount of
mechanical induced draft is
required.
2. Consideration is given to typically
higher static pressure requirements for larger installations, for
the type of fuel burned, and for
the type of draft control installed.
3. Where pressure requirements
are unknown, or believed to be
unusually severe, ask for complete performance curves or consult factory.

DUCT BOOSTER
MODEL DB-2

IL

Heater
390F
BTU Flue Gas
Input S.P. CFM

Heater
BTU
Input

530F
Flue Gas
S.P. CFM

69000 .034

48

72000 .047

36

58000 .048

33

105000 .042

72

109000 .053

55

92000 .057

48

111000 .043

72

104000 .052

52

74000 .052

39

100000 .041

68

34000 .042

17

25000 .035

13

270000 .063

190

330000 .085

166

295000 .092

163

356000 .073

246

377000 .090

190

300000 .093

169

360000 .075

259

330000 .085

166

230000 .080

118

320000 .068

217

222000 .075

110

123000 .065

65

900000 .125

590 1200000 .143

603 1100000 .147

566

1110000 .135

765 1330000 .150

653 1100000 .148

566

10

1250000 .140

850 1260000 .145

615

840000 .136

440

12

1030000 .128

710

357

400000 .100

211

1460000 .145 1010 1970000 .175

989 1700000 .180

900

10

2080000 .170 1370 2460000 .185 1240 1900000 .180

1010

12

1920000 .160 1325 2230000 .182 1120 1500000 .170

789

14

1840000 .159 1270 1470000 .158

18

XL

Oil Firing
With
Bar. Draft
Control

16

HD

The Tjernlund Duct Booster is the


ORIGINAL money saving and energy efficient residential booster fan. It
increases the comfort level in hard
to heat or cool areas. No need to
adjust the whole house thermostat
or install auxillary heating or cooling
equipment. Fits round or flat forced
air heating/cooling ductwork. DB-2
features: easy installation, durability,
economical price and manual or
automatic operation. Boosts air flow
up to 275 CFM (8 duct).

Gas Firing
With
Bar. Draft
Control

Gas Firing
With
Draft Hood

710000 .115

740

825000 .135

453
184

900000 .120

620

650000 .113

340

350000 .095

650000 .099

450

440000 .095

220

200000 .075

106

16

4000000 .250 2760 4000000 .260 2010 3300000 .230

1763

18

3900000 .240 2650 3250000 .240 1660 2100000 .190

1103

20

2800000 .195 1935 2100000 .175 1079 1200000 .150

626

24

1500000 .150 1035 1100000 .125

503000 .110

266

20

5300000 .290 3690 5200000 .270 2440 3600000 .240

1870

24

3500000 .220 2415 3750000 .220 1680 2900000 .218

1550

527

MODEL D-3

MODEL I

Model PS 1505 Proving Switch (Available as accessory. Recommended)


Detects failure of motor or impeller & shuts off unit. (@ negative 0.05" w.c.)
Universal Control UC-1
Used in conjunction with PS1505 eliminates control circuit compatibility issues. The
UC-1 interlocks with dry contacts, 24VAC or 115V appliance control systems.
Simply connect the PS1505 to UC-1 and select the system voltage required.
Adjustable pre and post purge is also available. UC-1 can replace any relay or
timer/relay previously installed.

CLEAN AIR ONLY

DO NOT USE IN FLUE

Model
No.
DJ-3

Therm
Volts HZ RPM Watts Amps Prot.
115

1550

35

D-3

115

60

1550

I
IL

115

60

1725

XL

115
230

60

1725

HD

208
230
460

60

DB-2 DUCT BOOSTER

12

60

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

.43*

Unit
Dimensions (in)
H

Ship
Wt.

578

258

758

8 lbs.

712

812

8
1412

Slot

858 10 lbs.

4
418

1234 31 lbs.
15
34 lbs.

17

2
1312
1434

YES

1878

1812 1012

518 1634 53 lbs.

NO

27

1634 25

74

.96

YES

4HP

5.4

YES

4HP

10.8
5.4

1725 2 HP

6.3
6.4
3.2

7
834
10

2412 176 lbs.

* Impedance protected

CATALOG #37
www.centralfan.com

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

TJERNLUND PRODUCTS, INC.


SIDE WALL VENTING
See P. 13 for make-up (combustion) air devices
FLUE GAS TEMP 600F MAX. @ POWER VENTER
(DO NOT USE ON CONDENSING FURNACES)

HS-Series with Universal Control (UC-1)

UL

For all your gas and oil sidewall power venting needs. The UC-1
interlocks with dry contact 24VAC or 115V appliance control systems. UC-1 can replace any relay or timer/relay previously installed.
Adjustable pre & post purge, prover switch circuit and LED status
diagnostics indicators are all included. Accessories available for
multiple appliance control. (HSJ not recommended for oil).

Maximum Pipe Length (FT)


At Stack Temp
Inlet/
Outlet
Dia.

Model
Numbers

Vent
Pipe

BTU/HR
Input

4"

HS1
115V
1.76 amps

100'
100'
100'
23'

4"

150,000
200,000
250,000
300,000

100'
87'
40'
4'

60'
57'
12'
n

35'
27'
n
n

6"

150,000
200,000
250,000
300,000

100'
100'
100'
30'

100'
100'
92'
n

100'
100'
n
n

350,000
400,000
450,000
500,000
550,000
600,000

100'
100'
100'
100'
94'
15'

100'
100'
100'
72'
n
n

100'
100'
67'
n
n
n

350,000
400,000
450,000
500,000
550,000
600,000

100'
100'
100'
100'
100'
67'

100'
100'
100'
100'
n
n

100'
100'
100'
n
n
n

4"

6"

HS2
115V
2.0 amps

HS-3

100'
100'
100'
35'

4"

Inlet
Outlet
Dia.

Model
Numbers

Oil
Fired
500F

50,000
75,000
100,000
125,000

HSJ
115V
1.76 amps

Gas
Fired
300F 400F

Maximum Pipe Length (FT)


At Stack Temp

Not
Recommended

Vent
Pipe
Dia.

25%
Dilution 400F
Gas Fired
Power Burner
With
Barometric
Draft Control

8"

450,000
500,000
600,000
700,000

100'
100'
100'
7'

100'
100'
100'
100'

10"

450,000
500,000
600,000
700,000

100'
100'
100'
21'

100'
100'
100'
100'

8"

700,000
800,000
900,000
1,000,000
1,100,000
1,200,000

100'
100'
100'
70'
32'
5'

100'
100'
100'
100'
100'
100'

10"

700,000
800,000
900,000
1,000,000
1,100,000
1,200,000

100'
100'
100'
100'
97'
14'

100'
100'
100'
100'
100'
100'

12"

700,000
800,000
900,000
1,000,000
1,100,000
1,200,000

100'
100'
100'
100'
100'
34'

100'
100'
100'
100'
100'
100'

1,200,000
1,400,000
1,600,000
1,825,000

100'
100'
100'
29'

100'
100'
100'
100'

1,200,000
1,400,000
1,600,000
1,825,000

100'
100'
100'
72'

100'
100'
100'
100'

1,200,000
1,400,000
1,600,000
1,825,000

100'
100'
100'
100'

100'
100'
100'
100'

8"

115 VAC
1
4 HP
3.2 AMP

HS-4

8"

115 VAC
1
3 HP
6.3 AMP

6"

8"

BTU/HR
Input

100%
Dilution 300F
Gas Fired
Atmospheric
With
Draft Hood Or
Draft Diverter

10"

HS-5
115/208/230 VAC
1 HP
6.2 AMP @ 208
6.3 AMP @ 230
13.1 AMP @ 115

10"

12"

14"

Accessory Controls
VH1-3-4-6

Model

VH1-8-10

HIGH TEMPERATURE VENT HOOD

Description

MAC-1E

To interlock 1 additional appliance

MAC-4E

To interlock 3-5 additional appliances

WHK-E

To interlock a millivolt water heater

NOTE: INSTALLATION MUST COMPLY WITH APPLICABLE CODES.


Dimensions
A Dia.

VH1-3

3"

VH1-4

4"

VH1-6

6"

Model

Rough-In
Dimensions

5 4"

7 4"

6 4" sq.

Ship
Wt. Lbs.

Water Heater Vent Kit

Water heaters rated at 50,000 BTU/hr. or less can be


vented by the VP-2. Water heaters rated from 51,000
to 120,000 BTU/hr. can be vented by the VP-3. Both
packages come complete except for the pipe.

6 4" sq.

8 2"

10"

712" sq.

718"

13"

858"

738" 11"

8" sq.

812" dia.

778"

12"

912" 1012" 10"

9" dia.

10"

VH1-8

8"

1514"

9"

1838"

20"

812" dia

12

VH1-10

10"

1514"

9"

1838"

20"

1012" dia

13

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

CATALOG #37
www.centralfan.com

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

13

Tjernlund Products, Inc.

A cost effective way to ensure adequate combustion air for


maximum performance of heating appliances. The IN-FORCER
can be ducted up to 100 ft. allowing isolated mechanical rooms to
be supplied with outdoor combustion air. Optional control panel
allows interlock with up to 4 additional appliances.
Where the IN-FORCER supplies combustion and dilution air
each appliance must be electrically interlocked and supplied at the
rate of 50 CFM per 100,000 Btu/hr.

IN-FORCER MODEL APPLICATION CHART

Model

PAI-5*

5.4
Amps
115v

PAI-6*

5.8
Amps
115v

Not Applicable

Multiple IN-FORCERS may be installed for capacities larger than shown on chart. IN-FORCERS may be roof or wall mounted.

DIMENSIONS

*Universal Control Model UC-1


The UC-1 interlocks mechanical draft and combustion air systems with gas/oil
fired heating equipment. It can be activated by an 18-130 VAC heater control
signal, pressure switch or relay using a 5 VAC control supplied by dry contacts.
A UC-1 is needed with all PAI systems.

Accessory Controls
Model

Description

MAC-1E

To interlock 1 additional appliance

MAC-4E

To interlock 3-5 additional appliances

WHK-E

To interlock a millivolt water heater

14

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

CATALOG #37
www.centralfan.com

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

PAI-7

Not Applicable

PAI-6

12.6
Amps
115v
6.3/6.2
Amps
208/230

Gas
Power Burner
Max Duct
Rigid Duct
Length in
Diameter
Equiv. Feet
In Inches
100
6
100
6
100
6
100
6
100
6
100
6
100
6
100
6
98
6
100
8
100
8
100
8
100
8
100
8
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12

PAI-5

1.5
Amps
115v

Oil Flame Retention


With Barometric
Max Duct
Rigid Duct
Length in
Diameter
Equiv. Feet
In Inches
100
6
100
6
100
6
100
6
100
6
100
6
100
6
100
6
100
8
100
8
100
8
100
8
100
8
95
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12

PAI-4

PAI-4*

150,000
200,000
250,000
275,000
300,000
350,000
400,000
450,000
500,000
550,000
600,000
650,000
700,000
775,000
850,000
900,000
950,000
1,000,000
1,200,000
1,300,000
1,400,000
1,500,000
1,600,000
1,700,000
1,800,000
1,900,000
2,000,000
2,100,000
2,200,000
2,300,000
2,400,000
2,500,000
2,600,000
2,700,000
2,800,000
2,900,000
3,000,000
3,100,000
3,200,000
3,300,000
3,400,000
3,500,000
3,600,000
3,700,000

Gas Power Burner


With Barometric
Max Duct
Rigid Duct
Length in
Diameter
Equiv. Feet
In Inches
100
6
100
6
100
6
100
6
100
6
100
6
100
8
100
8
100
8
100
8
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
98
12

PAI-3

PAI-3*

1.26
Amps
115v

PAI-7*

BTU/HR
Input

Motor
Amps

Gas
Atmospheric
Max Duct
Rigid Duct
Length in
Diameter
Equiv. Feet
In Inches
100
6
100
6
100
6
100
8
100
8
100
8
100
8
52
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
95
10
100
12
100
12
100
12
100
12
100
12
100
12
100
12
98
12

Direct Drive Centrifugal Fans


FOR GENERAL VENTILATION SYSTEMS
INCLUDING RANGE HOOD EXHAUST
All fans by Fantech utilize unique external rotor motors. The motors totally enclosed design allows the fan to operate
in high moisture, lint and dust laden air. The motors are permanent split capacitor with automatic reset thermal overload protection and sealed ball bearings. All motors and impellers are designed as one integral unit for excellent motor
heat dissipation, even at a low RPM. Air stream temperature to 140F and 100% speed controllable.

RVF Series Wall Mount

Simple to install no extras are needed


Galvanized steel housing with Baked Enamel finish
Housing removable for easy access to motor and wiring
Variable speed controllable

RPM

RVF4XL

2700

RVF6XL

3000

RVF8XL

2900

1.42

CFM @ S.P. (inches of H2O)

120V 1
Amps

Model

UL

.1

.2

.4

.6

.84

180

172

154

136

118

1.46

360

346

315

285

258

410

392

348

312

282

235

Speed Control Model No. C64

.8

1.0

Ship
Wt. Lbs.

1.2

1.4

91

57

28

213

164

92

14

180

128

16

10

(See below for dampers.)

Dimensions In.
Model

RVF4XL

1014

13

114

RVF6XL

1414

17

112

RVF8XL

1414

17

112

RE Series Roof or Wall Mount

DAMPERS
Spring Loaded Butterfly
Dia. (in.)
4
6

UL

Suitable for pitched roof or wall mounting


Galvanized steel housing with Baked Powder Coat finish
Cover easily removable for access to motor and wiring
Variable speed controllable

Model

RPM

120v 1
Amps

RE6
RE8XL
RE10XL

2696
2830
3250

.80
1.48
3.61

227
409
753

199
362
721

CFM @ S.P. (Inches of H2O)


3
1
3
8
2
4
1

112

184
331
705

51
130
548

169
307
690

134
259
656

106
212
622

134

Ship
Wt. Lbs

508

15
15
20

Speed Control Model No. C64

Model
RSK4
RSK6

8
10
12

RSK8
RSK10
RSK12

14
16

RSK14
RSK16

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

Dimensions In.

CATALOG #37
www.centralfan.com

Model

RE6

13316

b
612

1512

RE8XL

1534

20

RE10XL

1934

1134

20

10

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

15

FG Series In-Line Mount


FOR GENERAL VENTILATION APPLICATIONS
Galvanized steel housing
Mounting bracket included for ease of installation

UL

External wiring box for ease of connection

Auto thermal
120V 1
AMPS
.73

CFM @ S.P. (Inches of H2O)


0
148

139

130

120

111

90

114
42

Ship
Wt. Lbs.
8

Duct
4"

RPM
2800

FG5XL

5"

2650

.76

191

175

161

146

131

102

75

45

FG6XL

6"

2950

1.26

392

368

346

326

305

263

228

191

150

11

FG8XL

1.
68

112

Model
FG4XL

8"

2950

1.31

521

496

469

440

411

345

282

231

180

12

FG10XL

10"

3000

2.11

590

565

541

519

496

442

394

339

290

14

FG12XL

12"

3250

3.21

801

783

765

747

729

692

655

611

566

21

Dimensions In.
d

FG4XL

934

FG5XL

934

FG6XL

658

1318

1338

10

1338

12

16

Model

FG8XL

1 8

1 8

FG10XL

5 8

1 8

FG12XL

8 4

1 16

1 16

FR Series In-Line Mount


FOR HOSTILE ENVIRONMENT VENTILATION

DB 10 DRYER
BOOSTER SWITCH

L
Housing manufactured of thermoplastic resin
UL listed for outdoor use or wet locations
Waterproof gasket on wiring box
Mounting bracket included
Auto thermal
DO NOT USE IN COMBUSTIBLE ATMOSPHERE

Allows FR110 or RVF4 to be used as


booster fan for residential clothes dryers. The automatic pressure switch
turns fan off and on in 10 minute
cycles only when dryer is running.
Allows fans to be used on runs up to
80' and 6 elbows of 4" rigid duct.
(120v only)

CFM @ S.P. (Inches of H2O)

120V 1
amps

.2

.4

.6

.8

1.0

Ship
Wt. Lbs

Model

Duct

RPM

1.5

FR110

4"

2900

.72

167

150

133

113

88

63

FR140

6"

2850

.53

214

190

162

132

99

46

FR160

6"

2750

1.14

289

260

233

206

179

154

89

FR225

8"

3100

1.35

429

400

366

332

297

260

168

11

FR250

10"

2850

2.04

649

600

553

506

454

403

294

13

Dimensions In.
PB100 BATH FAN
100 CFM fan, ceiling grille and grille
housing with damper. Uses 4" duct.

PB190 PREMIUM BATH FAN


190 CFM fan, ceiling grille and grille
housing with damper. Uses 6" duct.
Home Ventilating Institute guidelines
recommend one CFM per square foot
for bathrooms 100 ft2 and under. Over
100 ft2 use 50 CFM/fixture,
i.e., 1 toilet, 1 shower, 1 tub = 150 CFM.

Model

FR110

514

FR140

5 8

FR160

6 8

FR225

614

112

FR250

6 4

c
7

8
7
8
7
8
1
1 2
112

d1

d2

378

478

5 8

6 4

1134

5 8

6 4

1134

778

978

1314

1314

9 8

Speed Control
Mounting Clamps

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

912

Accessories:
4"

5"

6"

8"

10"

12"

C64

C64

C64

C64

C64

C64

Backdraft Damper RSK4 RSK5 RSK6 RSK8 RSK10

16

CATALOG #37
www.centralfan.com

FC4

FC5

FC6

FC8

FC10

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

RSK12
FC12

FKD Series In-Line Centrifugal Fans

Backward curve mixed flow fan impeller


100% Speed controllable ball bearing 115V motor with overload protection
Galvanized heavy gauge housing with baked powdercoat finish
Inlet and outlet slip type duct connections
Capable of operation in air stream temperatures up to 140F
Terminal box prewired
UL approved

CFM @ S.P. (INCHES H2O)

Model

NEW

FKD 8XL
FKD 10XL
FKD 12XL
FKD 14XL
FKD 16XL
FKD 18XL

RPM
2700
2850
1700
1550
1600
1700

120V
Amps+

Sones*

2.99
4.84
4.80
7.12
12.40
3.75**

14.1
21.0
18.7
19.9
25.0
32.0

1/4

3/8

761
1187
1832
2416
4014
5995

720
1147
1746
2303
3880
5874

1/2

680
1100
1649
2180
3743
5754

114

3/4

595
1006
1423
1936
3452
5500

499
911
1066
1662
3137
5199

393
810
606
1294
2794
4909

112

286
696

460

843
2379
4602

1242
3703

Ship
Wt.
Lbs
16
22
46
52
84
95

*The sound ratings shown are loudness values in fan sones at 5 ft. in hemispherical free field calculated per AMCA Standard 301. Values shown are for installation
Type A: free inlet fan sone levels @ 12" W.G. Dampers see pg. 15.
**FKD18XL 230/460V 3PH (amps shown are for 460V)

FKD 8XL-10XL

FKD 12XL-14XL-16XL-18XL
Dimensions (inches)
Model
FKD8XL
FKD10XL
FKD12XL
FKD14XL
FKD16XL
NEW FKD18XL

A
8
10
12
14
16
18

A1
12
14
16
18

A2
14
16
18
20

C
1212
14
1778
1934
2218
2214

D
1512
15
1878
2014
2314
2914

E
7
8

F
158
158
158
134

78

112
114
2

FSD Series In-Line Centrifugal Fans

Backward curve mixed flow fan impeller

100% Speed controllable ball bearing 115V motor with overload protection

Galvanized heavy gauge housing with baked powdercoat finish

Inlet and outlet ductmate type duct connections

Capable of operation in air stream temperatures up to 140F

Terminal box prewired

UL approved

CFM @ S.P. (INCHES H2O)

Model

RPM

120V
Amps+

FSD 18
FSD 20
FSD 22
FSD 26

1700
1600
1600
1700

4.80
6.36
15.00
3.82**

Sones*

12.4
14.1
21.0
27.0

2237
2921
4918
6644

1 4

1 2

2126
2766
4766
6473

1987
2605
4605
6317

1644
2241
4282
5981

1180
1829
3865
5608

658
1341
3337
5177

815
2716
3469

Ship
Wt.
Lbs

1308
1937

62
77
115
134

+Amperages are maximum for the given RPM. **FSD26 230/460V/3 Amps shown are for 460V.
*The sound ratings shown are loudness values in fan sones at 5 ft. in hemispherical free field calculated per AMCA
Standard 301. Values shown are for installation Type A: free inlet fan sone levels @ 12" W.G. FSD26 is @34" W.G.
Side View

Inlet View

Speed Controls

Dimensions (inches)
Model

A sq.

C sq.

Model

FSD18

1758

1534

C64

FSD 20

1934

1734

10

FSD 22

2112

C65

19

15

26

2014

C66

FSD 26

7
Note: Flanges extend 8" beyond
the A dimension

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

CATALOG #37
www.centralfan.com

Max. Amps

Additional Accessories:
Backdraft Dampers Pg. 8
Vibration Isolators Pg. 39
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

17

BATHROOM FANS

ut
Abo
s
Ask iscount
ity D
t
n
a
Qu

UL

AMCA CERTIFIED

688

671, 676, 684

HD50, HD80

679

655

CEILING OR WALL MOUNTING - With backdraft damper - Plastic grille

Control

CFM

Noise
Level
Sones

688*
671*
684*
676*

C64
C64
C64
C64

50
70
80
110

4.0
6.0
2.5
4.0

3
3
4
4

45
65
75
100

.9
1.15
.5
1.3

712
712
814
814

714
714
8
8

358
358
534
534

914
914
1118
1118

9
9
1058
1058

5
5
8
8

Commercial Duty
continuous operation

HD 50*
HD 80*

C64
C64

50
80

1.5
2.5

4
4

45
75

.4
.5

814
814

8
8

534
534

1014 x 1014
1014 x 1014

7
7

Fan with Light (100 watt)


Fan with Light & Heat (1300w.)

679*
655

#68
#66

70
70

3.5
4.0

4
4

65
65

2.
12.8

814
14

8
814

534
534

1118 x 958
1534 x 1058

8
14

All 115V. AC
Type
Bathroom fans

Model

Economy
Deluxe
Premium
Premium

Model 655 has separate blower for heater.


Optional model MHR control (see p.19)

Round
For
Outlet Area
Inches Sq. Ft.

*U.L. listed for use in tub/shower enclosure with GFCI wiring.

QTR80, QTR110

QTXE150

Amp

Housing Size
L
W
H

Grille
Size
x
x
x
x

Ship
Wt.
Lbs.

Metal grille for 671, 676, 684, 688 available.

QTR110L

162, 164

750

Model

Control**

CFM

Noise
Level
Sones

Fan Only
Fan Only
Fan Only
Fan w/Light/Nite Light

QTR80*
QTR110*
QTXE150*
QTR110L*

C64
C64
C64
#67

80
110
150
110

1.0
1.5
1.4
1.5

4
4
6
4

75
100
140
100

Fan w/Light/Nite Light

750*

#67

100

3.5

95

1.9

15 Rd.

12

Fan & 250 w. Infrared bulb (I bulb)


(2) 250w. Infrared bulbs (2 bulbs)

162
164

#68
#68

70
70

3.0
3.0

4
4

65
65

3.5
5.5

1212
1812

1112
12

534
612

1012 x 10
1012 x 16

8
10

All 115V. AC
Type

*U.L. listed for use in tub/shower enclosure with GFCI branch wiring.

Round
Outlet
Inches

For
Area
Sq. Ft. Amp

**Optional model MHR control (see page 19)

.7
.9
.5
1.8

Housing Size
L
W
H
1

11 4

10 8

7 8

Grille
Size
13 x 14
13 x 14
14 x 15
1238 x 14

Ship
Wt.
Lbs.
12.4
12.4
13.2
13.8

R40 Infrared bulbs not included.

Broan Kitchen & Bathroom Fans

L300KMG

502, 503

All 115V. AC
Type
Wall or
Ceiling
Mount
Ceiling
Mount only
(No dampers)

673

Model

CFM

Noise
Level
Sones

Outlet
Size
Inches

Fan
Size
Dia.

503
502
L300KMG*

160
270
286

5.5
7.0
2.8

314 x 10
314 x 10
8

8
10
Blower

Amp.
1.7
1.7
2.7

673
505
504

60
180
350

4.0
4.5
6.5

614
814
1014

6
8
10

1.0
1.5
1.7

504, 505

Housing Size
L
W
14
1634
1214

12
1378
1214

614 dia. X 5516


814 dia. X 7
1014 dia. X 7

White Polymer
Grille
Size

Ship
Wt.
Lbs.

314
314
1134

1112 sq.
1312 sq.
14 x 14

10
12
25

8 dia.
1114 sq.
1312 sq.

4
8
10

No. C64 variable speed control for all fans shown above.
No. 472 damper with reducer to 8" for Model 504
Metal grille for models 502, 503, 504, 505 available.
*Suitable for use above cooking surface. Motor is thermally protected for higher temp., galv. steel impeller, metal grille. Dishwasher safe aluminum mesh filter LAFI (12" x 12" p. 19)

18

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

CATALOG #37
www.centralfan.com

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

BROAN WALL FANS

With backdraft dampers - Unbreakable white polymer grilles (paintable)**

CFM

Noise
Level
Sones

RPM

Amp.

For Wall
Thickness

Exterior weatherhood

509
508

C64
C64

180
270

5.0
6.0

8
10

1500
1500

1.5
1.7

412 to 912
412 to 912

9"
11"

1114
1312

11
16

Chain-operated w/outside
door

507
506

C64
C64

250
480

5.0
6.5

8
10

1500
1500

1.5
1.7

412 to 912
412 to 912

9"
11"

1114
1312

11
13

Motor-door

12C

C64-3

380

4.5

10

1500

1.7

5 to 10

12" Sq.

1312

20

12" Sq.
12" Sq.

1312
1312

8
9

All 115V AC
Type

Model

Room to room thru wall

511
510

Control*

(on fan)
(on fan)

**Optional metal grille available for 12C, 506, 507, 508, 509

180
380

Blade
Dia.

3.5
5.5

8
10

1500
1500

3 to 5 2
3 to 512

1.5
1.7

Hole
Required
Dia.

Grille
Size
Sq.

Ship
Wt.
Lb.

*Optional model MHR control (see below) electronic delay switch.


ACCESSORIES

WALL CAP
Spring Loaded Damper
Black Enamel Finish
Model 639

Flat roof installation


Aluminum natural finish
Built-in screen

Curb mount installation


Aluminum natural finish
Built-in screen

Model 611

Model 611CM

SHORT EAVE ELBOW


Damper & Grille
Black Enamel Finish
Model 430

3" or 4" WALL CAP


Damper
Aluminum
Model 642

TRANSITIONS
Duct Transition

Model

314" x 10" to 6"


314" x 10" to 7"
314" x 10" to 8"

411
412
413

ROOF CAP
Damper & Bird Screen
Black Enamel Finish
Model 634
Model 644 (Alum.)

6", 7" or 8" WALL CAP


Damper & Bird Screen
Aluminum
Model 641 (6")
Model 643 (8")
(No screen)

ROOF CAP
3" or 4" Duct
Damper & Bird Screen
Black Enamel Finish
Model 636

SWITCHES

Washable Filters
Model
8" O Aluminum (fits 505 & 509)
10" O Aluminum (fits 12C, 504, 508, 510 & 511)
LAF1 12" x 12" (fits L300KMG)
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581

LONG EAVE ELBOW


Damper & Grille
Black Enamel Finish
Model 431

Model

Timers

C71-5
C71-15
C71-60
C72

5 min.
15 min.
60 min.
12 hr. (+ hold)

Control

Model
C64
C64-3
66
68
67

Vari-speedFor Model 12C


For Model 655
For Model 679, 162, 164
For QTR110L, 750

Model MHR: Electronic Fan-Light-Time Delay Control


120v 7.5 amp (fans) 120v 10.0 amp (heaters) 500 w. (lamps)
Adjustable timer allows fan operation after light switched off.

CATALOG #37
www.centralfan.com

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

19

L100
L150
L200
L250
L300

LOWEST SOUND LEVELS IN THE INDUSTRY

L400
L500
L700

L900
L1500

Attractive white grille blends with any decor.


Specially designed resilient motor mount helps eliminate vibration
Low RPM motors are permanently lubricated and thermally protected.
Rugged 20 ga. steel housing with 12" acoustic insulation.
Automatic backdraft damper located within duct connector.
8 position adjustable mounting brackets permit installation flexibility.
Available in ceiling or in-line models.
Air volume may be varied with speed control.
Available in 240 vac and 277 vac (Special order).

CFM*
static press. (in water)

Ceiling
Model

In-Line
Model

L100
L150

L100L
L150L

L200
L250
L300

Motor
Max.
120v
RPM Amps

Wt.
Lbs.

65
124

12
94

.8
1.4

640
710

1.1
1.3

6 Dia.

1214

1214

1134

14 x 14 (P)**

23

186
242
296

177
233
287

144
201
254

1.8
2.3
2.9

740
830
905

1.8
2.1
2.6

8 Dia.

1214

1214

1134

14 x 14 (P)**

23

344
463
640

299
434
607

182
339
534

2.4
3.1
4.6

735
810
960

1.4
2.2
2.9

412 x 1812

2112

1214

1134

2314 x 14 (S)

34

877 842
1438 1371

793
1285

636
1103

4.0
8.4

650
955

3.0
5.0

8 x 12

22

18

18

2378 x 1978 (S)

64

136
181

93
141

80
132

L200L
L250L
L300L

231
272
312

196
250
303

L400
L500
L700

L400L
L500L
L700L

480
538
722

388
491
667

L900
L1500

L900L
L1500L

918
1578

Housing (In.)
L
W
H

Grille
Molded Plastic (P)
Enameled Steel (S)

Sones
@ 110"

Outlet
Size (in.)

UL

*CFM is reduced slightly on in-line models

**Metal Grille L100-L300 Available at extra charge

High Volume Cabinet Ventilators

Designed for continuous operation.


May be installed in ceiling or wall.
Shipped in horizontal discharge - convertible to vertical discharge.
May be converted to ceiling fan with grille kit.
Air volume may be varied with speed control. (see below)
L2000 is 115v; L3500EXL is 230v 1

L2000L
L3500EXL
(shown with optional
grille and damper kit)

CFM
static press. (in water)
1

Model
L2000L

0
8
1891 1791

1657

1508

1347

808

1.0

L3500EXL

3608 3452

3278

3073

2893

2429

1693

UL

Motor

Sones
@ 110"
9.8

RPM
965

Volts
115

Amps
5.8

Wt.
Lbs.
89

14.8

1105

230

5.4

144

DIMENSIONS

Inlet

Outlet

Outside Dimensions

Model

L2000L

1238

3534

3334

734

1458

1458

L3500EXL

14 2

43 2

41 8

9 4

16 4

16 4

L
38
3

45 4

Mounting Hole Spacing


E
734
1

10 4

Grille

Width

Length

3334

1258

3958

1614

3958

41 4

12 8

47 8

18 8

4714

ACCESSORIES
Speed Controls
C64 (L100-L900)
C65 (L1500-L2000L)
C75 (L3500EXL) 230V
Duct Transition
423 - 4 2" x 18" to 10" (L400-500-700)
T81212 - 8" x 12" to 12" (L900-1500)
1

20

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

Wall Caps
641 - 6"
643 - 8"
613 - 12"
Roof Jacks
634 - 8"
437 - 12"

Damper Kit
D100 (L2000)
D101 (L3500EXL)
Grille Kit
G102 (L2000L)
G103 (L3500EXL)

CATALOG #37
www.centralfan.com

Radiation Dampers
RD1 L100-L300
RD2 L400-L700
RD3 L900 & L1500
Brick vent
BV8 - 734" x 818" x 4"
BV12 - 734" x 12" x 4"
BV16 - 734" x 1558" x 4"

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

The T-Series range boasts features and a


specification that marks a radical departure
from current unit ventilation technology.

Designer-styled

in two-tone grey to bring


slim sophisticated good looks to today's
commercial and residential environments.

A Speed Control Pack which gives one of

three fixed speeds at the time of installation


without the need for a Controller. When set
on High, T-Series fans give a performance
which outclasses competitive products.

Four sizes in each model, mean 12 performance options - so sizing is no longer a hit or
miss affair.

An

advanced interlocking shutter system


effectively closing against backdraft controlled by state-of-the-art electronics to
ensure quiet and reliable actuation whatever
the angle of installation. (exhaust or supply)

A new system of mounting for Window

and
Roof models which accommodates varying
mounting thicknesses. Wall models have telescopic liners for all types of walls and a neat
decorative trim.

For

cleaning, T-series units can be completely dismantled in minutes without the


need for special tools and all the non-electrical components can be washed thoroughly
in warm soapy water.
WINDOW MODEL
TX Modelwith electronically controlled integral shutter

Technical Data
WINDOW
MODEL
TX6WW

Mounting Exhaust Performance


Impeller Hole O
Guide (cfm)
O (in)

(in)
Low Medium High
714

6
1

55

2.7

TX6WL

1114 x 1138

158

205

233

55

196

257

313

60

1.9

60

1.9

TX7WL

7 2 1278 x 13

1014

275

403

467

95

2.8

TX9WL

1438 x 1434

302

443

513

95

2.8

12

1314

645

833

950

130

4.1

TX12WL

12

1738 x 1734

697

900

1027

130

4.1

Mounting Exhaust Performance


Impeller Hole
Guide (cfm)
O

(in)
O (in)
Low Medium High
6
1

TX7RF

7 2

TX9RF

9
12

714

55

2.7

918 x 958

174

225

257

55

2.7

284

60

1.9

TX7PL

7 2 1058 x 1118

216

282

344

60

1.9

1014

275

403

467

95

2.8

TX9PL

1218 x 1278

333

488

565

95

2.8

593

767

873

130

4.1

TX12PL

12

1514 x 1534

748

967

1108

130

4.1

TX6PL

Exhaust Performance
Guide (cfm)
Watts Sones
Low Medium High (Med) (Med)

233

13 4

172

Impeller Mounting
O (in) Hole (in)

178

147

PANEL
MODEL

8 4

116

Watts Sones
(Med) (Med)

2.7

284

TX12WW

TX12RF

210

Exhaust Performance
Guide (cfm)
Watts Sones
Low Medium High (Med) (Med)

233

TX9WW

TX6RF

184

Impeller Mounting
O (in) Hole (in)

178

7 2

ROOF
MODEL

145

WALL
MODEL

8 4

TX7WW

Watts Sones
(Med) (Med)

Darkroom Model: Exhaust or supply air ventilation without light intrusion . . .


automatic integral shutter. Darkroom model dimensions are similar to roof
model . . . except for the additional (interior) cowl. (derate 25%)

OPTIONAL CONTROLS (All models)

LIGHT-TIGHT GRILLE: black finish


Model LT 12 x 12
12" sq.

Model TFC 3 speed flush mntg. with reversing feature

Model LT 12 x 18

Model TSAT thermostat (41-86F)

12" x 18"

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

Model TSC 3 speed surface mntg. with reversing feature

Model HSTAT humidistat (45%-90% RH)

CATALOG #37
www.centralfan.com

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

21

IN-LINE CENTRIFUGAL
Direct drive or belt drive available
Galvanized steel construction
Aluminum airfoil impellernon-overloading
Bearing assembly L-10 life of 200,000 hours
Operation to 200F on belt drive applications; 140F direct drive
Versatile . . . mounts in any position . . . square in/out
Easy access to all parts without disconnection of duct
AMCA B Spark resistant construction standard

NOT FOR GREASE EXHAUST

DIRECT DRIVE

SEE PP. 17, 23, 24, 25 FOR OTHER IN-LINE FANS

Model
No.
XD100

XD120 B
C

HP
1

10

8
3

Single Phase
Three Phase
1 Speed 2 Speed 1 Speed 2 Speed
S
M
T
R
X

X
X

X(V)

X(V)
X

Accessories

@ 14"
Sones

Vib. Isol.

Vib. Isol.

Fan
RPM

3.0
7.5
10.0

1050
1300
1550

460
570
680

4.4
7.5
14.0

955
1140
1750

890
1068
1635

350
480
610

380
530

230
430

805
995
1590

650
910
1540

730
1490

Maximum RPM shown with the standard one speed motor. For all lower RPMs add solid state speed controller.
Model
No.
A
XB9 B
C
D

BELT DRIVE

B
XB120 C
D
E
C
D
XB137 E
F
G
D
E
XB161 F
G
H

11.7
14.0
16.7
21.0

1878
2274
2524
2933

675
875
990
1100

525
700
875
1000

325
600
750
975

X
X

Supp. Brkt. w/Isol.


Drive Cover
Chemical
Resist. Coat

13
15
18
21

1570
1725
2060
2335

1360
1515
1845
2110

1235
1410
1760
2040

930
1250
1670
1965

X
X
X
X
X

X
X
X
X

Supp.Brkt. w/Isol.
Drive Cover
Chemical
Resistant
Coating

12
14
18
21
26

1365
1605
1830
2060
2310

1790
2195
2560
2920
3310

1490
1945
2360
2755
3170

1275
1705
2120
2555
3010

X
X
X

X
X
X
X
X

X
X
X
X
X

Supp.Brkt. w/Isol.
Drive Cover
Chemical
Resistant
Coating

12
14
17
20
24

1210
1365
1570
1710
1865

2710
3095
3600
3940
4320

2485
2930
3470
3825
4215

2165
2680
3300
3690
4100

2375
3070
3510
3960

X
X

X
X
X
X
X

X
X
X
X

Supp.Brkt. w/Isol.
Drive Cover
Chemical
Resistant
Coating

13
14
18
23
27

985
1055
1250
1410
1525

4285
4590
5560
6350
6910

3830
4215
5250
6080
6660

3375
3815
4930
5800
6400

1890
3160
4590
5510
6140

Accessories

X
X
X
X

X
X

X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X
X

X
X
X
X

X
X
X
X
X

1
112
1

2
3
4
1
1
1 2
2
3

V=control included

Supp. Brkt. w/Isol.


Drive Cover
Chemical
Resist. Coat

E
F
XB200 G
H
J

1
1
1 2
2
3

X
X
X
X
X

F
G
XB245
H
J
K

1
1
1 2
2
3
5

X
X
X
X

X
X
X
X
X

X
X
X
X
X

Supp.Brkt. w/Isol.
Drive Cover
Chemical
Resistant
Coating

12
16
19
25
34

735
855
965
1100
1295

6210
7375
8425
9700
11530

5675
6940
8045
9370
11250

4130
6435
7645
9055
10970

G
H
XB300
J
K
L

112
2
3
5
712

X
X
X

X
X
X
X
X

X
X
X
X
X

Supp.Brkt. w/Isol.
Drive Cover
Chemical
Resistant
Coating

13
16
20
23
30

595
670
775
875
1010

8340
9610
11340
12960
15125

7255
8720
10690
12370
14625

5560
7665
9800
11700
14090

*Single phase 120v or 230v. (X) Available models


See p. 10 for 208v, other special motors and controls.

Disconnect switches (p. 43)

37
290
105
1450

1290

860

(X) Available models

112

180
450
625
875

150
450
675

212

O.V. = 1.0 CFM


150
500

260

O.V. = .571 CFM


760
1545
1880

740
1580

720

680

O.V. = .421 CFM


1530
1930
2350
2825

5060
7160
8680
10860

1500
2045
2485

2160
3055
3580

3155
4885
5590

7600
10070

1350
2240

1550

5870
9080
12150

22

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

Model
(Direct)
XD100
XD120

A
14
1778

B
18916
2478

Model
(Belt)
XB9
XB120
XB137
XB161
XB200
XB245
XB300
XB365

A
14
1778
2012
2414
30
3634
45
5434

B
1812
2478
2818
321116
3934
48116
58516
71116

48

64
100

130
155

170
220

1445
3030

230

1155

O.V. = .184 CFM

300

3030
4870

330

2305

O.V. = .119 CFM

400

9180

450

5613

O.V. = .082 CFM


5570
8880
10925
13500

Ship
Wt.

O.V. = .291 CFM

10470

5665

600

720

Backdraft dampers, see p. 8.

DIMENSIONS

MODEL XB

Ship
Wt.

O.V. =.571 CFM

6
4
3
1
2
1
14
3
1
2
3
4
1
13
2
3
4

Fan
RPM

S*

@ 2"
Sones

HP
1

Approx. CFM
Static Pressure (inches of water)

Impeller
Size
978
111516
C
Max
12
11316
11316
131116
131116
131116
1638
1638

D
Max
14
1514
1514
1812
1812
1812
20
20

MODEL XD

Impeller
Size
10316
111516
131116
1
16 8
20
2412
30
3612

CATALOG #37
www.centralfan.com

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

Duct Blower and Duct Filter


All-purpose indoor cabinet blower with optional compact filter.
Install in any position-ball bearing blower
Insulated cabinet for quiet operation
Drawer type filter rack for easy maintenance
Access panels on both sides

DUCT
BLOWER

Model
No.

207

209

210

A
B
C
D
E

O.V.
FPM
759
1139
1519
1899
2409

RPM
567
822
975
1073
1469

BHP
.02
.07
.14
.21
.43

RPM
737
822
975
1149
1414

BHP
.04
.05
.14
.24
.48

RPM
1019
1051
1134
1272
1526

X
X
X
X

800
1000
1200
1400
1600

951
1189
1427
1665
1902

468
534
613
696
782

.06
.09
.15
.23
.34

581
625
682
750
828

.07
.12
.18
.26
.37

786
802
834
881
936

.12
.17
.24
.33
.44

974
964
979
1009
1050

.19
.23
.30
.40
.52

1130
1118
1115
1132
1162

.26
.31
.38
.48
.60

1379
1384
1371
1362

X
X
X
X

1000
1200
1400
1600
1800

964
1157
1350
1543
1736

422
470
525
582
642

.06
.10
.15
.22
.29

531
559
593
640
693

.09
.13
.18
.25
.33

713
728
749
770
807

.15
.20
.26
.33
.41

869
873
886
905
928

.23
.28
.34
.42
.51

998
1005
1009
1021
1040

.31
.40
.43
.52
.62

X
X
X
X
X

1600
2000
2400
2800
3200
3400

1097
1371
1646
1920
2194
2331

423
489
562
640
721
762

.12
.21
.35
.53
.78
.92

974
1217
1461
1704
1948
2142
1297
1461
1621
1785
1945
2110
2270
2464

323
372
431
491
553
604
302
328
356
384
413
442
472
508

.15
.26
.42
.59
.94
1.23
.40
.55
.72
.94
1.19
1.50
1.83
2.31

.17
.26
.40
.59
.83
.98
.21
.33
.49
.72
1.02
1.32
.50
.66
.83
1.06
1.32
1.65
1.98
2.48

658
690
734
786
846
877
529
546
575
608
646
679
448
460
473
491
510
532
555
584

.26
.37
.53
.73
.99
1.14
.34
.46
.66
.91
1.22
1.51
.74
.92
1.11
1.35
1.61
1.94
2.28
2.81

786
809
840
882
932
959
631
650
667
693
725
753
526
538
551
563
575
592
611
635

.35
.49
.66
.88
1.16
1.32
.49
.64
.81
1.10
1.44
1.77
.97
1.18
1.41
1.68
1.95
2.45
2.66
3.18

905
915
941
973
1015

2000
2500
3000
3500
4000
4400
4000
4500
5000
5500
6000
6500
7000
7600

507
559
620
687
758
796
399
432
471
523
580
628
351
373
395
420
445
471
499
533

716
736
754
771
798
823
610
605
615
630
641
653
666
687

B
C
9209 D
E

4
3
1
2
3
4
1

B
C
9210 D
E

4
3
1
2
3
4
1

C
3
D 12
212
3
4
9212 E
F 1
1
G 1 2
E
F
215
9215 G
H
J

F
G
9218 H
J
K

OUTDOOR DUCT BLOWER WITH HOOD


AND WEATHER RESISTANT CABINET

Single
Speed
1 3
HP S T CFM
1
X

400
6
1
X
X
600
4
1
X
X
800
3
1
X
X
1000
2
3
X
X
1300
4

218

For outdoor installation use heavy duty,


weather resistant 9200 models.

FILTER

1
112
2
3

1
112
2
3
5

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X

X
X
X
X
X

X
X
X
X
X

8"

4"

ACCESSORIES:
Vibration hangers
Aluminum mesh filters
Intake hood (includes filter)

RPM
2020
2051
2038
2053

.41
.48
.56
.65

1578
1590

.56
.67

1210
1221
1229

.47
.55
.65

1387

.66

.47
.61
.79
1.03
1.35

1106
1108
1118
1142

.72
.88
1.08
1.35

1276
1279
1278

.99
1.19
1.40

1420

1.27

.63
.83
1.09
1.27
1.65
2.01
1.28
1.44
1.69
2.00
2.32
2.7
3.07
3.61

856
879
899
918
935
950
754
752
746
741
750
765
777
791

.96
1.19
1.48
1.80
2.14
2.44
1.93
2.10
2.39
2.65
3.00
3.45
3.91
4.53

971
998
1020
1039
1058

1.30
1.58
1.92
2.31
2.74

1071
1101
1125
1146

1.65
2.0
2.37
2.81

868
871
869
864
857
858
868

2.62
2.96
3.22
3.58
3.79
4.20
4.69

967
971
973
972
969

3.32
3.75
4.03
4.51
4.82

DUCT BLOWER

18

1538

209

21

210

2214

212
215
218

80

90
90

100
115

150
170

240
275

330

INTAKE HOOD

FILTER

**Incl. Filters.
Duct Blower Dimension

207

.72

.
H09
H10
H12
H15
H18

*S.P. drop @ max. CFM shown above.

Model

80
1751

Intake Hood
Model**

.171
.124
.124
.241
.182
.241

Ht.
B

Ship
Wt.
Lbs.
70

SEE P. 45 FOR ROOF MOUNTED, SIDE INTAKE AIR SUPPLY UNITS

Aluminum Mesh Filter


Model
S.P.*

Width
A

212"
RPM BHP
2242
.42
2286
.58
2292
.71

2"
BHP
.37
.45
.58
.70

*Static pressure reduction on blowers designed for higher pressure could result in motor overload.
(X) Available models

2 speed 1 or 3 page 10
1 phase 120v or 230v. See p. 10 for 208v 1

F207
F209
F210
F212
F215
F218

Static Pressure (inches water)*


3
1"
112"
4"
BHP RPM BHP RPM BHP RPM BHP
.07
1257
.11
1448
.15 1761
.24
.12
1255
.16
1437
.20 1777
.32
.18
1308
.24
1473
.30 1768
.41
.29
1400
.35
1540
.43 1809
.57
.67
1618
.62
1713
.69

2"

Length
C

Filter Dimensions

Outlet

Inlet

23

814

9316

1412

958

114

114

18

23

1014

111316

1712

1134

114

134

20

2434

1138

1318

1834

1338

114

134

27

23

3312

28

2712

13716

1558

2312

1618

114

134

32

1578

1858

28

1912

258

134

4112

34

44

1958

2258

35

24

234

134

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

8
7
8
7
8
7
8
7
8
118

CATALOG #37
www.centralfan.com

Inlet
M

Filter Size

1578

1338

1734

1538

16

1312

1418 x 1658

19

16

21

21

18

1918

1618

1634 x 1978

2014

18

26

2214

20

2038

1818

1834 x 2118
2134 x 2578

25

21

31

27

23

2518

2118

3012

25

34

3212

2634

3058

2518

2534 x 31

3538

3158

40

37

3314

3514

3112

3214 x 3578

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

23

Tubemaster
BELT DRIVE
TUBEAXIAL FANS

Heavy duty all welded aluminum propeller


Permanently lubricated ball bearings
Maximum operating temperature to 200 F
Tough acrylic epoxy finish
Designed to operate in any position

Note: Axial fans running at relatively high tip speeds tend to be noisy.
Describe installation when ordering if fan noise is a potential problem.
Important: Duct must not be sharply reduced or turned near fan inlet
or discharge.

Model
No.
C
HA12 D
E
C
D
HA16 E
F
D
HA18 E
F
G

Approx. CFM
Static pressure (inches water)

Approx.
1 Phase* 3 Phase Fan
HP
S
T
RPM
1

3
1
2
3
4
1
3
1
2
3
4
1
1

2
4

1
112
3

X
X
X

X
X
X

2320
2680
3070

1970
2270
2600

1790
2120
2470

1670
2030
2400

1520
1930
2330

X
X
X
X

X
X
X
X

1976
2267
2600
2855

2994
3435
3940
4326

2613
3121
3666
4077

2353
2919
3525
3952

1929
2683
3337
3806

2871
3463

X
X
X
X

X
X
X
X

1730
1980
2180
2495

4060
4640
5120
5860

3660
4270
4800
5580

3440
4080
4640
5450

3160
3880
4450
5300

2000
3370
4050
4980

X
X
X
X
X

1250
1375
1570
1730
1980

6750
7450
8500
9350
10660

5950
6750
7900
8800
10220

5520
6360
7600
8520
9970

5000
5910
7250
8250
9720

4650
6450
7950
9200

E
F
HA24 G
H
J

1
112
2
3

X
X
X
X
X

F
G
HA30 H
J
K

1
112
2
3
5

X
X
X
X
.

X
X
X
X
X

942
1078
1187
1358
1610

10000
11500
12600
14450
17120

8800
10450
11750
13700
16440

8050
9850
11250
13250
16070

7050
9100
10650
12800
15680

G
HA36 H
J
K

112
2
3
5

X
X
X

X
X
X
X

799
880
1007
1193

14550
16050
18350
21750

12900
14500
17000
20600

11900
13700
16300
20100

10400
12650
15500
19400

H
HA42 J
K
L
M

2
3
5
712
10

X
X

X
X
X
X
X

683
781
926
1060
1170

19650
22500
26650
30500
33550

17250
20400
25000
29100
32240

15750
19250
24000
28300
31520

13700
17900
23000
27600
30780

*1 phase 120v or 230v. See p.10 for 208v 1

1660
2130

6700
9150
11700
14890
7800
11700
18100
13800
20750
25900
29260

Est.
Ship
Wt.

1870

49
51
54

2924

67
69
72
73

4600

74
77
78
88

7630
8600

114
115
125
134
151

10250
13980

229
239
248
265
279

10250
16450

284
293
310
324

17700
23800
27530

564
581
595
646
666

See Page 10 for


Enclosed motors
Exp. Proof motors
Multi-speed motors
Motor controls

ACCESSORIES

Size
HA12
HA16
HA18
HA24

ComAcc- Chem.
panion Drive Belt ess resist. Disc.
Flanges Cover Guard Door Coat* Sw.
X
X
X
X
X X
X
X
X
X
X X
X
X
X
X
X X
X
X
X
X
X X

HA30
HA36
HA42

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

*See page 38 for coatings


(X) Available accessories

See page 10 for 2-speed motors. (X) Available models

DIMENSIONS (INCHES)
Model

HA12

14.69

12.00

13.44

12.19

17.00

HA16

18.75

16.50

17.50

16.06

19.00

HA18

21.13

16.50

19.88

18.44

20.50

HA24

27.00

18.00

25.75

24.38

24.00

HA30

33.75

24.00

32.25

30.50

29.00

HA36

39.75

29.00

38.25

36.50

32.00

HA42

45.75

32.00

44.25

42.50

37.00

Dimensions are shown in inches.

24

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

CATALOG #37
www.centralfan.com

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

CENTRIFAN
BELT DRIVE
IN-LINE CENTRIFUGAL FAN

Backward curved wheel


Space saving in-line, tubular design
Floor, wall or ceiling installation
Vane straightened air flow (except C1050)

Suitable for Kitchen Hood Exhaust

C
D
E
C1050 F
G
H

1 Speed
S

H.P.
1

3
2
4

1
3

1
112
2
1

3
2
4

Bearings and drive out of airstream


All welded, rugged 10-16 ga. steel const.
Max. temp. 150F
Arr. #9 Class 1

See Pages 16, 17, 22, 23, 24 For Other In-Line Fans

SINGLE PHASE*
Model
No.

THREE PHASE

2 Speed 1 Speed
M
T

Approx. CFM

2 Speed
R

RPM

O.Vel @
1
4 S.P.

S.P.

S.P.

S.P.

1
S.P.

112
S.P.

2
S.P.

212
S.P.

3
S.P.

312
S.P.

4
S.P.

X
X
X
X
X
X

X
X
X

X
X
X
X
X
X

2010
2310
2639
2904
3325
3660

920
1086
1260
1408
1624
1794

1000
1180
1370
1530
1765
1950

900
1100
1300
1460
1700
1900

790
1000
1220
1390
1640
1850

640
900
1140
1310
1580
1800

m
605
950
1160
1450
1675

m
m
660
970
1315
1560

m
m
m
640
1150
1425

m
m
m
m
935
1275

m
m
m
m
m
1100

m
m
m
m
m
800

X
X
X
X
X
X
X

X
X
X
X

X
X
X
X
X
X
X

X
X
X
X

1447
1657
1897
2088
2390
2630
3011

1000
1173
1367
1500
1740
1933
2250

1500
1760
2050
2250
2610
2900
3375

1360
1640
1950
2175
2550
2825
3275

1175
1510
1850
2090
2460
2750
3210

750
1335
1725
2000
2400
2700
3150

m
m
1375
1750
2200
2550
3025

m
m
m
1275
1975
2350
2900

m
m
m
m
1625
2150
2750

m
m
m
m
m
1700
2550

m
m
m
m
m
m
2325

m
m
m
m
m
m
2000

X
X
X
X
X
X

X
X
X

X
X
X
X
X
X
X

X
X
X
X
X
X
X

1194
1367
1504
1722
1895
2170
2458

1040
1217
1361
1560
1726
1991
2257

2350
2750
3075
3525
3900
4500
5100

2150
2600
2950
3410
3800
4435
5015

1900
2400
2775
3300
3700
4325
4950

m
2150
2600
3150
3600
4235
4890

m
m
1900
2800
3300
4025
4700

2100
2925
3800
4500

m
m
m
m
m
3450
4300

m
m
m
m
m
2950
4000

m
m
m
m
m
m
3675

m
m
m
m
m
m
3100

C
D
E
C1220 F
G
H
J

1
112
2
3

D
E
F
C1500 G
H
J
K

1
112
2
3
5

E
F
C1820 G
H
J
K

1
112
2
3
5

X
X
X
X
X

X
X

X
X
X
X
X
X

X
X
X
X
X
X

1010
1112
1273
1401
1603
1901

1017
1130
1325
1479
1717
2048

3375
3750
4400
4910
5700
6800

3100
3500
4150
4700
5500
6625

2775
3210
3950
4500
5300
6450

2000
2900
3700
4300
5100
6300

m
m
2900
3800
4725
6000

m
m
m
m
4300
5700

m
m
m
m
3200
5350

m
m
m
m
m
4900

m
m
m
m
m
3900

m
m
m
m
m
m

F
G
H
C2220
J
K
L

1
112
2
3
5
712

X
X
X
X

X
X
X
X
X
X

X
X
X
X
X
X

790
910
1000
1160
1370
1550

1000
1200
1350
1550
1850
2000

5100
5900
6700
7800
9200
10300

4800
5700
6400
7500
9000
10100

4100
5200
6000
7200
8700
10000

3400
4600
5600
6700
8500
9800

m
m
4480
6100
8000
9500

5000
7200
9100

6500
8500

m
m
m
m
5580
7900

m
m
m
m
m
7100

m
m
m
m
m
6100

G
H
C2450 J
K
L
M

112
2
3
5
712
10

X
X
X

X
X
X
X
X
X

X
X
X
X
X

780
850
980
1160
1330
1470

1120
1250
1480
1720
2000
2200

6700
7400
8800
10400
12000
13000

6300
7200
8400
9800
11800
13000

5600
6600
7850
9700
11300
12600

4800
6000
7600
9500
11000
12200

m
m
6500
8800
10500
12000

m
m
m
7800
9800
11400

m
m
m
6600
9300
10800

m
m
m
m
8400
10000

m
m
m
m
7200
9000

m
m
m
m
m
8400

1
3

2
4

*1 phase 120v or 230v. See page 10 for 208v 1 and other special motors.

Bare
Wt.

110

130

195

260

390

460

(X) Available models

Model

Pair
Comp.
Flanges

Belt
Guard

Floor
Legs

Access
Door

Chemical
Resist.
Coating

Weather
Cover

Spark Resist.

C1050

C1220

C1500

C1820

C2220

C2450

Ceiling
Vlb.
Brackets Isolators
X

B*

C*

Disc.
Switch

SEE PAGES 16, 17, 22, 23, 24


FOR OTHER CENTRIFUGAL
IN-LINE FANS

*See page 38 for description of spark resist. constr.

(X) Available accessories

Fan Dimensions
Size

C1050

14

C1220

16

C1500
C1820
C2220
C2450

8
16
5
20 16
11
24 16
5
30 16
1
33 4

16

18

2
8
5
26 8
3
32 8
1
39 2
5
43 8
18
21

16

18

8
16
5
22 16
11
26 16
3
32 4
3
35 4

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

F
23

2
2

2
1
18 4
1
22 2

26

8
1
31 8
7
36 8

24

30

18

39

33

19

43

14

21

4
1
12 4
3
14 8

8
1
29 8
7
34 8

10

2
1
22 4
1
26 2

12
1

2
2

CATALOG #37
www.centralfan.com

16
16
9
16
9
16
9
16
7
8

19

15

22

17

4
4
6
6

16
16
5
16
5
16
5
16
3
8

12

4
8
1
24 2
1
29 2

12

16

BC

Shaft
Dia.

8
16
5
21 16
11
25 16
9
31 16
1
34 2

1
3

16
16
7
1 16
1

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

25

RADIAL BLADE BLOWERS


DIRECT DRIVE - ARRANGEMENT 4

Recommended for small kitchen hoods where grease filters may or may not
be used-also for air containing dirt, dust, lint or other foreign material.
Wheels-Constructed with straight radial blades of heavy cast aluminum-Self
cleaning.
Dynamically balanced, Spark resistant. Suitable for 250F. Max.
CLOCKWISE ROTATION-bottom horizontal discharge is furnished unless otherwise specified. Discharge position and rotation can be changed. Rotation is as
viewed from motor end. (See page 31.)

CW-BH Blower

ASSEMBLED AND TESTED-WITH BALL BEARING MOTOR


WHEN ORDERING: INCLUDE PHASE, VOLTS, ROTATION & DISCHARGE
115/230V
CFM
Static pressure (inches water)

SINGLE PHASE THREE PHASE

Model
No.
KE
KE
KE
KE
KE

8
9
11
12
14

1 Spd. 2 Spd.

1 Spd. 2 Spd.

RPM

X
X
X
X
X

X
X
X
X

X
X
X
X
X

X
X
X

1750
1750
1750
1750
1750

550
880
1430
2375
3420

6
1
4
1
2
1
2

Special Motors: Multi-speed, enclosed, expl. prf - see page 10


*Single phase - 120v or 230v
For 208v 1 - see page 10.

HP

510
825
1385
2300
3325

470
765
1335
2220
3230

425
705
1275
2140
3125

365
635
1225
2060
3025

150
480
1100
1890
2820

200
945
1700
2595

114

112

730
1485
2350

Ship
Wt.
Lb.

430
1185
2045

35
40
60
120
150

350
1010

(X) Available models

ACCESSORIES
Blower
Model
KE
KE
KE
KE
KE

Vibration
Pads

Drive
Cover

Chemical
Resistant
Coating

X
X
X
X
X

X
X
X
X
X

X
X
X
X
X

8
9
11
12
14

*SquareModel A14 shutter (p. 8.)

Shutter
to fit
Discharge

Disc.
Switch

X
X
X
X
X*

X
X
X
X
X

(X) Available accessories

Outlet Velocity (FPM) =

CFM
Area (Sq. Ft.)

Tip Speed (FPM)


At 1750 RPM = 458 x Dia. (in.)
Construction is of 16 gauge steel housings and bases
Arc welded for rigidity.
Finish is Dark Gray epoxy.

Blower Dimensions
Model
No.
KE-8

Wheel
734 x 4

KE-9

9x5

KE-11

10 8 x 5 8

KE-12

12 2 x 7 2

KE-14

1312 x 818

Bore*
1

2
1
2
5
8
5
8
7
8

Certified Dimension Prints furnished upon request


OUTLET
A

11
1

12 8
3

14 4
3

814

538

9
1

10 4
3

11 4
1

6 2
8
5

16 8

10 2

13 4

9 8

1758

1012

1458

1034

5 8

F
7
7

6 8

7 2

7 8

8 4

834

INLET
G

M*

458

634

678

1034

5 8

7 4

7 8

6 4

9 8

8 8

13 4

10 8

8 2

11 2

10 2

15 16

1118

938

1258

1138

1634

2
1
2
3
4
7
8
7
8

6 4
8
1

11 4
1

N
3

8
3
8
3
8
9
16
9
16

334

812

9 4

938

1134

4 16

5 16 10
3

10 4
1

6 8

13 4

13 4 11 8

17

1412

1458 1214

17

*Bore & "M" varies with frame.

26

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

CATALOG #37
www.centralfan.com

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

Pressure Blowers
DIRECT DRIVE - ARRANGEMENT 4
Pressure blowers are generally used on industrial applications for small
high pressure exhaust systems where air is laden with dust or grit and also for
supplying high pressure air for conveying and cooking. Not suitable for heavy,
coarse material. See p. 34.
WHEELSConstructed with straight radial blades of heavy cast aluminum
for self cleaning features, dynamically balanced and designed for efficient
operationSpark resistant. Suitable for 250F Max.
CLOCKWISE ROTATIONBottom Horizontal discharge is furnished
unless otherwise specified. Discharge position and rotation can be changed.
Rotation is as viewed from motor end. (See p.31.)
CW-BH Blower

ASSEMBLED AND TESTED - WITH BALL BEARING MOTOR


WHEN ORDERING: INCLUDE PHASE, VOLTS, ROTATION AND DISCHARGE

Model
No.
PW
PW
PW
PW
PW

8
9
11
12
14

HP

With Standard
Open Motor
1 Phase* 3 Phase
S
T

3
1
3

X
X
X
X

1
2
5

X
X
X
X
X

*Single phase is 115V or 230V

RPM

3500
3500
3500
3500
3500

291
526
800
1190
2280

231
470
741
1130
2180

CFM
Static pressure (inches water)
5
6
7
8

165
410
676
1065
2070

330
600
1000
1960

200
500
930
1840

400
860
1720

300
780
1570

690
1400

575
1240

10

11

410
1080

880

12

Ship
Wt.
Lb.

670

35
40
65
80
135

(X) Available models

ACCESSORIES
Special Motor
Model
PW
PW
PW
PW
PW

8
9
11
12
14

Chemical
Vibration Drive Resistant
3
Pads Cover Coating

Enclosed

Exp.Proof

X
X
X

X
X
X
X
X

X
X
X

See p. 5 for motor description

X
X
X

X
X
X
X
X

X
X
X
X
X

Disc.
Switch

X
X
X
X
X

X
X
X
X
X

(X) Available accessories

Outlet Velocity (FPM) =

CFM
Area (Sq. Ft.)

OV
[4005
]2

Vel. Press.=

Tip Speed (FPM)


At 3500 RPM = 916 x Dia. (in.)
Construction is of 16 gauge steel housings and
basesArc welded for rigidity.
Finish is Dark Gray Baked epoxy.

Blower Dimensions
Blower

Wheel
3

PW-8

7 4 x 2 4

PW-9

9 x 234

PW-11

1058 x 3

PW-12

1212 x 3

PW-14

1312 x 438

Bore*

Certified Dimension Prints furnished upon request


OUTLET
A

11

1218

312

312

558

1434

312

678

712

17

612

718

534

9916

2
2
5
8
7
8
118

1758

1114

INLET
P

16

6 8

8 2

2034

712

938

758

2034

858

958

2018

22

5 8

4 8

5 8

5 8

638

534

678

634

714

612

814

712

1012

958

1138

2
2
3
4
3
4
1

11

13 8

12

1458

16

1134

1814

16

10

1058

1838

15

1112

1258

2112

15

714

*Could vary depending on motor frame size used.

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

CATALOG #37
www.centralfan.com

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

27

DIRECT DRIVE UTILITY BLOWERS


FORWARD CURVE WHEELS - SINGLE INLET - ARRANGEMENT 4
For general ventilation where duct systems are required. Compact, easy to mount and quiet in operation, these
blowers are designed to deliver large volumes of air economically. Ideal for wash rooms, boiler rooms, restaurants, and
small hood exhaust.

Note: Low static pressure systems may overload certain motors. Where this condition exists, increase the static pressure with duct work, dampers, etc.
CLOCKWISE ROTATIONBottom horizontal discharge (as shown in photo) furnished unless otherwise specified.
DISCHARGE POSITION easily changed to any one of eight different positions. Rotation as viewed from the motor end.
(See page 31.)
Suitable for temperatures to 250F. (500 with slinger)
Wheels are heavy gauge steel construction. Available with spark resistant aluminum wheels.
CW-BH Blower

ASSEMBLED & TESTED: With Open Ball Bearing Motor.


CFM

Model

HP

D5 A
A
D6
B

A
D8
C

6
6
1
6
1
6
1
3

D9 C

14

D11 E

12

Static Pressure (inches water)

120v Single Phase 3 Phase


1 Speed 2 Speed 1 Speed
S
M
T

184
390
595

169
330
560

144
250
515

112
100
470

420

365

300

1140
1750

760
1150

680
1085

620
1050

535
1005

430
960

915

865

RPM

1750
1140
1750

60

X
X
X

X
X(v)
X

X
X

X(v)
X

X(v)

850
1140

875
1180

835
1160

780
1125

680
1090

470
1035

965

855

850
1140

1520
2060

1380
1970

1290
1870

1145
1800

1010
1710

860
1605

1500

(V) = Variable speed includes solid state control

Ship
Wt.

114

25
25
25
750

40
40

580

70
1290

80

1020

(X) Available models

HIGH SPEED UTILITY BLOWERS


For high static pressure applications such as garage monoxide systems, electronic cooling and installations requiring extra long duct lengths.
115/230V
CFM
Static pressure (inches water)

SINGLE PHASE THREE PHASE

Model
No.
D**
D9 E**
F**
F**
D11 G**
H**

1 Spd. 2 Spd.

1 Spd. 2 Spd.

HP

RPM

1/2

X
X
X

X
X
X

X
X

1750

X
X
X

X
X
1720

1
112
2

X
X
X

X
X
X

1750

X
X
X

2
3
4

3/4

1020 895
X
X
1675 1620
X
X
X

X
X
X

*120v or 230v 1 See p.10 for 208v 1 motors. **D9D Not available spark resistant or CCW.
EXTRAS
Model
No.

1 1/4

1 1/2

1 3/4

810
1550
1550

733
1445
1445

615
1290
1290

2 1/4

1100
1100

X
1900
2500

1465
1840
2415

1425
1730
2240

1280
1600
2130

2 1/2

Ship
Wt.
Lb.

2 3/4

60
70
80
1120
1450
1990

X = Low S.P. will cause motor overload.

910
1280
1850

100
110
120

1040
1660

(X) Available models

Spark Shutter
Chemical
XP
Vib. Resist. to fit
Heat Resist.
Motor
Pads Wheel Disch. Slinger Coating 1 Phase

Drive
Cover

D5
D6
D8

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

D9
D11

X
X

X
X

X
X

X
X

X
X

X
X

X
X

*SquareModel A8 (Page 8) See p. 5 for motor description (X)Available accessories

SEE PAGES 36, 37, 38 FOR SOLID PVC BLOWERS

BLOWER DIMENSIONS
Model
No.
D5
D6
D8
D9
D11 E,H
D11 F
D11 G

Wheel

4 x 212
614 x 3
734 x 378
1
9 x 4 2
5
10 8 x 514
1058 x 3
5
10 8 x 4
4

28

B
3

8
938

8
11

8
14 4
3

8
8
1

11

D
1

8
738
814
3
10 4
3
11 4
5

7
8

12

*M varies with motor frame size

OUTLET

8
414
538
1
6 2
3

E
3

8
6 8
5

4
414
3

7
7
10

INLET
G
1

2
1
2
1
2
1
2
3
4

H
1

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

M*

2
1178
1212
1
13 4
1512

458

634

678

D9, C, E, F wheel = 9 x 412

J
3

8
6 4

4
9 8

8
8 8
7

11

N
3

8
3
8
3
8
3
8
3
8

4
318
334
3
4 8
2

8
718

812

9
10

4
10 4

As above (D11) except as shown


D9D wheel = 9 x 3 (cw steel only)

CATALOG #37
www.centralfan.com

X
5

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

812
7

8
4

11

BELT DRIVE UTILITY BLOWERS


Recommended for clean air ventilation where static pressures do not vary
over a wide range. Use backward curved blowers (next page) where system
conditions vary or pressure not known.
Not recommended for kitchen hood exhaust.
BLOWER
DIMENSIONS
PAGE 31

Wheel rotation and discharge position - page 31


Blower dimensions - page 31
Special motors and controls - page 12
CCW

SIZES SHOWN ARE NORMAL STOCK. OTHER SIZES ALSO AVAILABLE.

115/230v
SINGLE PHASE
Model
No.
A
B
8 C
D
E
A
B
9 C
D
E
B
C
11 D
E
F
C
D
12 E
F
G
D
E
15 F
G
H
E
F
18 G
H
J

HP
1

6
4
3
1
2
3
4
1
6
1
4
1
3
1
2
3
4
1
4
1
3
1
2
3
4
1
1

1
1

3
1
2
3
4
1
112
1

2
4

1
112
2
3

1
112
2
3
3

CCW-TH Blower

See Note Below for CFM vs. RPM vs. S.P. Relationship
THREE PHASE

@ 4" S.P.

1 Speed 2 Speed 1 Speed 2 Speed Blower


S
M
T
R
RPM*

Approx. CFM*
Static pressure (inches water)
4
1
112
2

O.V.
FPM

X
X
X
X
X

X
X
X
X

X
X
X
X

1200
1300
1400
1600
1800

2200
2700
2900
3400
4000

650
800
850
1000
1200

590
700
800
950
1150

560
650
750
900
1100

500
600
700
850
1050

X
X
X
X
X

X
X
X
X

X
X
X
X

800
900
1000
1200
1400

1700
2000
2200
2600
3000

800
950
1050
1200
1400

750
875
1000
1150
1350

650
800
950
1100
1300

600
750
850
1000
1250

X
X
X
X
X

X
X
X
X
X

X
X
X
X
X

X
X
X

700
800
900
1100
1200

1700
2000
2400
2700
3100

1100
1300
1500
1700
2000

1050
1200
1400
1600
1900

950
1100
1250
1550
1800

800
1000
1200
1500
1700

X
X
X
X
X

X
X
X
X

X
X
X
X
X

X
X
X
X

600
700
800
900
1000

1900
2200
2600
2900
3400

1650
1900
2200
2500
2900

1500
1750
2100
2400
2800

1300
1650
2000
2200
2700

1150
1500
1900
2150
2600

X
X
X
X
X

X
X
X

X
X
X
X
X

X
X
X
X
X

500
600
700
800
900

2000
2300
2600
2900
3300

2500
2900
3300
3700
4200

2350
2800
3200
3600
4100

2100
2700
3000
3500
3800

1900
2400
2800
3400
3700

X
X
X
X
X

X
X

X
X
X
X
X

X
X
X
X
X

400
500
550
600
700

1900
2200
2500
2800
3100

3600
4100
4700
5300
5800

3400
3800
4500
5000
5700

3200
3600
4300
4800
5600

2800
3400
4100
4700
5500

X
X

X
X
X
X
X

X
X
X
X
X

350
400
450
500
550

1900
2100
2400
2700
3100

4300
4800
5600
6200
7200

4000
4500
5300
6000
7000

3500
4200
5000
5700
6700

3000
3700
4700
5300
6500

E
F
20 G
H
J

1
112
2
3

X
X
X
X
X

F
G
22 H
J
K

1
112
2
3
5

X
X
X
X

X
X
X
X
X

X
X
X
X
X

350
400
425
475
500

2000
2400
2600
3000
3200

5600
6700
7300
8500
9000

5000
6200
6800
8000
9000

4700
5600
6400
7600
9000

4200
5200
6200
7400
9000

F
G
24 H
J
K

1
112
2
3
5

X
X
X
X

X
X
X
X
X

X
X
X
X
X

300
350
400
450
500

1900
2200
2500
2900
3500

6600
7700
8800
10000
12000

5900
7200
8300
9600
11600

5200
6600
7600
9000
11100

4200
5900
6900
8500
10500

500
650
800
950

Ship
Wt.

O.V. = 3.38 x CFM

60

500
750
900

650
800

750

80

O.V. = 2.14 X CFM


750
950
1200

900
1100

1000

65

900

90

O.V. = 1.57 X CFM


1050
1350
1600

1500

1300

105

O.V. = 1.17 X CFM


1200
1700
2000
2500

1400
1700
2300

1500
2000

1800

O.V. = .78 X CFM


2000
2500
3100
3500

2100
2800
3300

2400
3000

2700

O.V. = .53 X CFM


2800
3600
4200
5300

3200
3800
4900

3500
4500

4100

4800

4100

180

200
265

290
300

340
400
420

6200
7800

5200
7400

7000

O.V. = .29 X CFM


5100
6000
7500
9800

160

320
4000
5500

O.V. = .35 X CFM


4600
5400
6700
8400

140

280

O.V. = .43 X CFM


3900
4800
6000

75

5000
6000
8900

5800
7800

6500

430
460

510

*Exhibited blower RPM (above) relates to 4 " static pressure performance only. Higher RPM are necessary to yield the performance shown at higher static pressures.
AMCA CLASSIFICATION
FOR SPARK RESISTANT
CONSTRUCTION
TYPE A
All parts of the fan in contact with
the air or gas being handled shall
be made of nonferrous material.
Steps must also be taken to
assure that the impeller, bearings,
and shaft are adequately attached
and/or restrained to prevent a lateral or axial shift in these components.

Model
8
9
11
12
15
18
20
22
24

Weather
Vib.
Cover Isolators
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

Max temp. for Type "B" = 250F.

Disch.
Shutter
X
X
X
X
X
X
X
X
X

For special motors - p.10

Access
Door
X
X
X
X
X
X
X
X
X

Blower Dimensions: (Page 31)

TYPE B
The fan shall have a nonferrous impeller and nonferrous ring about the opening through which the shaft passes.
Ferrous hubs, shafts, and hardware are allowed provided construction is such that a shift of impeller or shaft will not
permit two ferrous parts of the fan to rub or strike. Steps must also be taken to assure that the impeller, bearings,
and shaft are adequately attached and/or restrained to prevent a lateral or axial shift in these components.

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

Drain
X
X
X
X
X
X
X
X
X

CATALOG #37
www.centralfan.com

Chem. Spark Resist.


Resist.
Coat
B
C
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
NOT AVAILABLE
See Page 30 for Backward Curve

Low static pressure can result in motor overload on blowers designed to operate at higher static pressures.

Coatings described p. 38

Heat
Slinger
500F
X
X
X
X
X
X
X
X
X

Disc.
Switch
X
X
X
X
X
X
X
X
X

(X) Available acces-

TYPE C
The fan shall be so constructed that a shift
of the impeller or shaft will not permit two
ferrous parts of the fan to rub or strike.

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

29

ULTRAFAN-PAK
BELT DRIVE UTILITY BLOWERS
NON-OVERLOADING
Baked epoxy finish standard.
Heavy gauge all welded construction.

AIR FOIL CONSTR.


STD. FOR SIZE 270
AND LARGER

250F max. operating temp. (500F with heat slinger)


Full class I performance to 5" static pressureAMCA certified.
Self-aligning pillow block ball bearings with grease fitting (100,000 hrs.)

Available in CW or CCW rotation and eight different discharge positions. (see next page)
Suitable for kitchen hood exhaust, dirt laden air, or where system pressures may
vary or are unknown.

CW-BH Blower

SINGLE PHASE
Model
No.
C
D
105 E
F
D
E
122 F
G
D
E
135 F
G

THREE PHASE

1 Speed 2 Speed 1 Speed 2 Speed


HP
S
M
T
R
1

3
1
2
3
4
1
1

2
4

1
112
1

2
3
4
1
112
3

@12" S.P.
Blower
RPM

O.V.
FPM

Approx. CFM*
Static pressure (inches water)
1
2
212
3
3 2

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X

2069
2474
2890
3167

2100
2500
3000
3300

1300
1600
1900
2100

1200
1500
1800
2000

1100
1400
1700
1900

900
1300
1600
1800

700
1000
1400
1700

800
1300
1500

1000
1400

X
X
X
X

X
X
X

X
X
X
X

X
X
X
X

1744
1964
2187
2484

2300
2700
3000
3500

2000
2300
2600
3000

1800
2200
2500
2900

1700
2100
2400
2800

1400
1900
2200
2600

1200
1600
2000
2500

1300
1700
2300

1500
2100

X
X
X
X

X
X
X

X
X
X
X

X
X
X
X

1454
1666
1886
2107

2100
2500
2900
3300

2200
2600
3000
3400

2100
2500
2800
3300

1900
2300
2700
3200

1400
2000
2400
3000

1600
2100
2700

1700
2500

2200

X
X

X
X
X
X

X
X
X
X

1490
1652
1900
2106

2400
2700
3200
3600

3100
3500
4100
4600

2800
3200
3900
4400

2600
3000
3700
4200

2100
2600
3300
3900

1700
2200
3000
3500

2600
3300

2000
2900

800
1200

1500 CFM Max. @ 5"


2 HP**

2400 CFM Max. @ 5"


3 HP**

1
1
1 2
2

F
G
165 H
J

1
112
2
3

X
X
X
X

X
X
X
X

X
X
X
X

1391
1604
1789
2070

2500
3000
3300
3900

3900
4600
5200
6100

3600
4400
5000
5900

3300
4100
4700
5700

2800
3600
4300
5200

2100
3200
3900
4800

2700
3400
4500

3000
4100

F
G
182 H
J

1
1
1 2
2
3

X
X
X
X

X
X
X
X

X
X
X
X

1195
1358
1501
1740

2300
2700
3000
3500

4300
5000
5600
6600

3900
4800
5400
6400

3600
4500
5200
6200

3000
3900
4900
5700

3400
4200
5300

3600
4900

3000
4500

G
H
200 J
K

112
2
3
5

X
X
X

X
X
X
X

X
X
X
X

1169
1293
1453
1759

2500
2800
3200
3900

5700
6400
7300
9000

5400
6100
7200
8800

5000
5800
7000
8600

4300
5100
6300
8200

3400
4500
6000
7700

3500
5300
7300

4500
6800

G
H
222 J
K

112
2
3
5

X
X
X

X
X
X
X

X
X
X
X

954
1051
1214
1418

2300
2600
3000
3600

6500
7300
8600
10200

6100
6900
8200
9800

5600
6500
7900
9700

4500
5600
7000
9300

4500
6400
8700

5400
7900

G
H
245 J
K
L

112
2
3
5
712

X
X
X

X
X
X
X
X

X
X
X
X
X

810
897
1035
1233
1419

2100
2400
2800
3400
4000

7300 6600 5900


8300 7700 7200
9800 9300 8900
11900 11500 11100
13900 13500 13000

4500
5900
7700
10300
12300

6600
9500
11600

8800
7600
10800 10000

9300

H
J
270 K
L

2
3
5
712

X
X

X
X
X
X

X
X
X
X

936
1046
1261
1448

2100
2400
2900
3400

8800 8000 7400


10000 9600 9200
12300 12000 11300
14300 14000 13600

6300
5000
8100
7100
10600
9500
12900 12000

6200
8800
8100
11000 10500

7300
9600

H
J
300 K
L

2
3
5
1
7 2

X
X

X
X
X
X

X
X
X
X

839
980
1177
1328

2100
2500
3100
3500

10800 9600 8700


12900 12000 11000
15800 15100 14200
18000 17600 17000

6700
9400
7400
12900 11400
16000 14200

10300
8500
13300 12600

J
K
330 L
M

3
5
1
7 2
10

X
X
X
X

X
X
X

859
1053
1213
1246

2400
3000
3500
3900

15000
18800
21900
24200

10000
14300 12300
17700 16000
20800 19500

10000
8200
14400 13000
18000 16700

3000 CFM Max. @ 5"


5 HP**
2500
3500 CFM Max. @ 5"
5 HP**
3800
4400 CFM Max. @ 5"
5 HP**
3900
5000 CFM Max. @ 5"
5 HP**
6200
6500 CFM Max. @ 5"
7 12 HP**

7300

6300

7900 CFM Max. @ 5"


10 HP**

9200 CFM Max. @ 5"


10 HP**

12000 CFM Max. @ 5"


15 HP**
10700
14000 CFM Max. @ 5"
15 HP**
15000

*CFM Exhibited is max for HP shown. Each model is capable of higher CFM than shown if equipped with larger motors at higher blower RPM. Note max. motor sizes.
**Max. motor size 2-speed switches - page 10. (X) Available models

30

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

CATALOG #37
www.centralfan.com

1800

X
X
X
X

12600
16100
20000
22200

2000 CFM Max. @ 5"


3 HP**

E
F
150 G
H

13500
17200
21000
23500

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

ULTRAFAN-PAK
Max.
Disch.
CFM*
Shutter (75% F.A.)

Vib.
Isolators

Weather
Cover

Model

Access
Door

Drain

Chem.
Resist.
Coat**

Spark Resist.

Blower with Motor

Heat
Slinger

Disc.
Switch

Ship Wt.

HP

105
122

X
X

X
X

X
X

1400
1900

X
X

X
X

X
X

X
X

X
X

X
X

X
X

100
190

1
112

135
150

X
X

X
X

X
X

2300
2800

X
X

X
X

X
X

X
X

X
X

X
X

X
X

210
230

112
2

165
182

X
X

X
X

X
X

2900
3500

X
X

X
X

X
X

X
X

X
X

X
X

X
X

280
350

3
3

200
222

X
X

X
X

X
X

4300
5200

X
X

X
X

X
X

X
X

X
X

X
X

X
X

480
480

5
5

245
270

X
X

X
X

X
X

6300
7700

X
X

X
X

X
X

X
X

X
X

X
X

X
X

620
720

712
712

300
330

X
X

X
X

X
X

9400
9500

X
X

X
X

X
X

X
X

X
X

X
X

X
X

820
1100

712
10

*When centrifugal fan outlet velocities exceed 2000 ft/min. shutters and other fittings should be located at least 212 duct diameters of straight duct
from the blower discharge. Unpredictable shutter performance will result if the shutter is on the blower discharge. Blower performance is enhanced by
a properly designed expander (evas) mounted on the discharge. Shutters ( and other fittings) should be installed downstream of the evas.
**See p. 38 for coatings and pp. 36 and 37 for PVC and FRP blowers. See p. 29 for spark resistant construction. (X) Available accessories
Blower Rotation & Discharge Designation (viewed from drive side)

Peerless ULTRAFAN-PAK Class I Arr. 10

OUTLET (OUTSIDE)

DIMENSIONS
Shaft
Dia.
Size Size Wheel
FC BC
Dia. CL. 1
8

734

9
105

15

10 2
1012

11
12

4
3
4
3
4
3
4

INLET (OUTSIDE)

TH, DB, BH, UB


Straight Disch.
A

Max.
Motor
Frame

BAU, TAU, TAD, BAD


Angular Disch.

918 13

814

538

1414

712

458

634

678

1038

614

738

514

2018

334

18

1812

1038 13

1034

612

1414

838

634

558

734

718

1158

712

814

618

2034

4516

18

1812

12 8 13

11 4

14 4

10 4

7 8

6 4

9 8

8 16

13 4

8 8

9 8

7 8

19 8

12 8

20 2

17

1278 13

1134

1414

1034

778

634

918

8116

1314

878

958

718

2112

518

10

2012

17

958

2378

638

1314

1114

1234

2514

20

122

1214

1638 1312 1314

958

1312

1434

1018

812

1112

1012

1658

1034

1212

135

1312

1758 1312 1458 1034

1312

16

1118

938

1258

1138

1814

1178

1334

10

2438

1412

1238

1378

2578

20

150

15

1914 1512 1614 1134

1512

1758

1238

1038

1418

1238

2018

1314

1514

1118

2678

712

1618

1338

1478

2758

22

165

1612

2138 15

1512

1934

1358

1138

1512

1358

2178

1458

1634

1214

2712

812

1778

1412

17

3018

22

1734 13
5

18

182

18 4

1 16

23 8 17

19 8 14 4

17 2

21 2

15

12 8

17 8

14 8

24 8

16

18 2

13 8

30 8

20

200

20

1316

25

2112 1578

17

2338

1612

1334

1834

1534

2638

1758

2038

1478

3112

22

222

2214

1316

2738 1612 24

1738

17

2534

1814

1514

2078

1714

29

1912

2258

1612

24

245

2412

1716

3014 1612 2614 1914

1634

2358

2018

1678

23

1978

3212

2112

2478

270

27

1716

33

2114

1612

2614

2218

1812

2514

2112

3538

2358

300

30

11116

3614 1612 3214 2338

1612

2912

2458

2012

2818

2358

3938

330

33

11116

3912 2138 3538 2578

2158

3318

2718

2212

3078

2558

43

17

1612 29

19 8

15 4

18 4

33 8

25

10

2112

1778

2018

3614

25

3234

1058

2378

1938

2258

3934

26

1814

3358

1134

2638

2114

2412

4278

26

2738

20

3458

1258

29

2334

2612

47

26

2638

3012

2214

36

1334

3214

26

2834

5178

27

2878

3312

2438

4138

15

3538

2838

3118

5818

3038

9 8

V
7

16
7
16
7
16
7
16
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
7
8

Size

12

145T

12

145T

14

145T

14

145T

17

182T

17

182T

1778

182T

1912

184T

2178

184T

2334

213T

2618

213T

2734

215T

3012

215T

3334

254T

3838

254T

NOTE: Letters C and D are outside housing dimensions.

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

CATALOG #37
www.centralfan.com

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

31

New York General Purpose Blowers


BACKWARD CURVE - BELT DRIVE - SINGLE INLET - ARRANGEMENT 10
FULL AMCA CLASS II CONSTRUCTION
Rugged heavy gauge steel construction for dependable, trouble free
heavy duty service.
AIRSTREAM TEMPERATURES TO 650F
Heat slingers for temperature > 200F
Sizes 12 and 15 require PLR wheel > 200F
CHOICE OF TWO WHEEL DESIGNS BOTH STOCKED
Acoustafoil-airfoil blade is quieter and more efficient for relatively clean air
PLR-flat BC blade for particulate laden air.
STABLE PERFORMANCE FOR VAV SYSTEMS
Acoustafoil wheel yields stable pressure curve from wide open to completely closed off.
Motors are standard ODP
See p.10 for special motors

CW-TH

CW Rotation

SEE P.33 FOR


BLOWER DIMENSIONS

Performance data exhibited are for the acoustafoil wheel and depict typical maximum CFM at designated motor HP. Complete AMCA certified data
are available. PLR wheel performance will be different, especially for higher S.P. and corresponding low CFM. Both AcF and PLR models are stocked.
Acoustafoil

SINGLE PHASE

Model
No.

HP
3

THREE PHASE

@ 2" S.P.

1 Speed 2 Speed Blower


T
R*
RPM

O.V.
FPM

2500
2800
3250
3600
3800
n

1800
2200
2700
3200
3400
3400

1 Speed
S

2 Speed
M
X

X
X
X
X
X
X

E
F
G
123 H
J
K

1
1
1 2
2
3
5

X
X
X
X
X
X

F
G
153 H
J
K
L

1
1
1 2
2
3
5
1
7 2

X
X
X
X
X
X

X
X
X
X
X
X

X
X
X
X

1940
2220
2480
2860
2966
n

1800
2300
2700
3300
3400
3400

G
H
J
183 K
L
M

1 2
2
3
5
1
7 2
10

X
X
X
X
X

X
X
X
X
X
X

X
X
X

1550
1720
2000
2352
n
n

1800
2200
2800
3400
3400
3400

H
J
K
223
L
M
N

2
3
5
1
7 2
10
15

X
X

X
X
X
X
X
X

X
X
X
X

1250
1500
1800
2012
n
n

1700
2300
3000
3400
3400
3400

J
K
273 L
M
N
P

3
5
1
7 2
10
15
20

X
X
X
X
X
X

X
X
X

1000
1220
1420
1563
n
n

1800
2500
3100
3400
3400
3400

K
L
M
303 N
P
W

5
1
7 2
10
15
20
25

X
X
X
X
X
X

X
X

1020
1180
1345
1397
n
n

2200
2800
3300
3400
3400
3400

L
M
N
333
P
W
X

7
10
15
20
25
30

X
X
X
X
X
X

1000
1120
1270
n
n
n

2500
3000
3400
3400
3400
3400

*2 speed - 1 winding

See page 10 for special motors and motor controls.

2230
2550
2920
2923

1930
2250
2680
2923

1740
2060
2540
2920
2923
MAX. Speed - 4900 RPM
3340
3850
4350
4385

2900
3580
3920
4385

3050
3200
3750
4385

Model AcF Approx. CFM


Static Pressure (inches water)
1
2
2 2
3

1520
1870
2340
2710
2923

1275
1600
2180
2520
2923

1030
1380
2000
2370
2923

(687)
950
1610
2040
2610
2923

(687)

(687)

(687)

1200
1700
2385
2923

765
1350
2100
2923

1400
2600

2300
2930
3400
4280
4385

1900
2610
3130
3930
4385

1500
2390
2900
3770
4385

(1031)
1600
2420
3300
4385

(1031)

(1031)

(1031)

1650
2840
4280
4385

2000
3700
4385

1000
2900
4127

3460
4225
5320
6527

2850
3780
4960
6527

2115
3100
4560
6200
6527

(1535)
1900
3600
5450
6527

(1535)

(1535)

(1535)

2420
4730
6500
6527

1500
3840
5800
6527

2000
4300
6100

4700
6500
8500
9689

3800
5600
7900
9689

2650
4800
7350
9400
9689

(2279)
3280
5900
8300
9689

(2279)

(2279)

(2279)

4560
7000
9100
9689

2950
6000
8100
9689

3200
5680
9100

7100
10400
12800
14245

6000
9500
11900
14245

4300
8400
11000
13400
14245

(3351)
3800
9500
12000
14245

(3351)
3355
7000
10400
14000
14245

(3351)

(3351)

4800
8200
12550
14245

4180
9150
12700

11200
14000
16900
17600

10000
13000
15700
17600

8400
12000
14800
17600

4750
9400
13000
16600
17600

(4135)
6300
10000
14800
17600

(4135)
4000
7200
13000
16200
17600

(4135)

15800
18000
21300

14000
17200
21300

12700
16000
20050
21300

8700
13000
18000
21300

5500
9200
15400
19000
21300

(5007)
6200
12300
17000
20500
21300

(5007)

Max. Speed - 3800 RPM


4980
5620
6500

4570
5280
6100
6527

4150
4800
5680
6527

Max. Speed - 3005 RPM


6950
8500
9689

6300
7880
9650
9689

5600
7000
9100
9689

Max. Speed - 2570 RPM


10850
13000
14245

9500
12000
14245

8700
11000
13700
14245

Max. Speed - 2010 RPM


15000
17600

14000
16400
17600

12700
15000
17600

Max. Speed - 1805 RPM


19000
21300

18000
21000
21300

17000
19800
21300

Max. Speed - 1650 RPM

7700
12200
15800

6260
11200
16000
19000

(X) Available models

ACCESSORIES
Set of
Vib. Disch. Access
Pads Shutter Door
X
X
X
X
X
X

Chem. Spark Resist.


Resist.
Drain Coating*
B
C
X
X
X
X
X
X
X
X

AcF
Model
123
153

Drive
Cover
X
X

183
223

X
X

X
X

X
X

X
X

X
X

X
X

X
X

273
303
333

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

See page 33 for blower dimensions. Solid PVC and FRP blowers pp. 36 and 37.
(X) Available accessories

32

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

Disc.
Switch
X
X

Heat
Slinger
X
X

Bare
Wt.
145
195

X
X

X
X

X
X

300
425

X
X
X

X
X
X

X
X
X

645
720
940

*Blower coatings p.38.

See p. 29 for description

CATALOG #37
www.centralfan.com

AMCA Spark Resist Options


TYPE B: Blower equipped with Aluminum
wheel and shaft ring. (Not suitable for abrasive or 200F plus. Use Type C.)
TYPE C: Blower equipped with non-ferrous
inlet cone, non-ferrous rubbing blocks, and
ring at housing opening thru which shaft
passes.
See p. 29 for AMCA spark resist. options.
SEE P. 33 FOR AVAILABLE
DISCHARGE POSITIONS
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581

New York General Purpose Blower


BACKWARD CURVE - BELT DRIVE - SINGLE INLET - ARRANGEMENT 10
AVAILABLE FAN DISCHARGES - VIEWED FROM DRIVE SIDE

NEW YORK GEN. PURPOSE BLOWER - CLASS 2 -ARR. 10 - PLR WHEEL AND ACOUSTAFOIL WHEEL

DIMENSIONS (INCHES)
OUTLET

INLET

OUTLET

Model

12
15
18
22
27
30
33

1512
1712
2114
2512
3212
3212
3912

10
12
14
17
2012
2212
2412

1238
1518
1812
2212
2714
3038
3338

1334
1678
2012
2478
3014
3312
3678

778
934
1134
1438
1738
1938
2114

13
1578
1938
2358
2858
3178
35

1038
1234
1512
1878
2278
2538
28

31316
36516
381316
4578
5114
5312
5834

218
318
318
318
418
418
418

212
3
312
4
5
512
6

1312
1612
20
2412
30
33
3612

938
1138
1378
1678
2038
2258
2478

Shaft
Model

Dia.

12
15
18
22
27
30
33

658
758
938
1138
1338
1412
1558

1638
1838
1738
2038
2034
2034
2334

738
878
938
1078
1358
1358
16

612
8
814
934
1134
1134
14

8
912
1014
1134
1434
1434
17

1158
1418
1714
21
2538
2814
3118

1614
1934
2358
2834
3434
3838
4218

1278
1534
1918
2314
2814
3138
3458

914
1138
1378
1634
2038
2258
2514

1716
1716
11116
11516
11516
11516
2316

*Approximate shipping weight in lbs.


Model no. is approx. wheel dia.

Keyway

Base
holes

8 x 316
3
8 x 316
3
8 x 316
1
2 x 14
1
2 x 14
1
2 x 14
1
2 x 14

16
9
16
9
16
9
16
3
4
3
4
3
4

N
191516
211516
211516
26
2678
2678
2978

CATALOG #37
www.centralfan.com

Q
618
714
834
1014
1212
1338
1434

Maximum
motor frame**

Bare
fan
weight*

Open

TE

145
195
300
425
645
720
940

184T
215T
215T
256T
284T
284T
324T

184T
215T
215T
254T
254T
254T
286T

**These maxima can be exceeded on most model sizes. . . with special assembly techniques

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

O
3112
35916
38916
4558
5012
5234
58

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

Tolerance:

8"

33

NEW YORK G.I. BLOWERS


GENERAL INDUSTRIAL - BELT DRIVEN - FLAT RADIAL WHEELS
INDUSTRIAL AIR-MOVING APPLICATIONS
Dust Collection
Combustion air
Pneumatic Conveying
Heat recovery
Moisture blow-off
Incinerators
Oven and dryer exhaust

(NICKELALUMINUM
BRONZE)

CW-TH

LS WHEEL
(STEEL)

CW-UB
Models 144 & Larger
Series 20 Arrangement 10

Flat radial-blade design best for material-conveying applications with airstreams containing
coarse material or heavy dust and particulate.
Models 85, 106, 126 With nickel-aluminum bronze wheel 180F Max. temp. (300 with heat
slinger)
Model 144 & up - With steel wheels Type LS 200F Max. temp. (600 with heat slinger)

Compact Models 85, 106, 126


Arrangement 9

AMCA CERTIFIED

AMCA CERTIFIED

ASSEMBLED & TESTED- WITH OPEN BALL BEARING MOTOR & ADJUSTABLE SHEAVE DRIVE

4
3
1
2
3
4
1
2
3
4

B
C
85 D
E

X
X
X
X

D
E
106 F
G
H

X
X
X
X
X

1
112
2
3

E
F
126 G
H
J

X
X
X
X
X

1
112
2
3

Series
20

3 PHASE
1 SP
2 SP
T
R

1 PHASE*

Model
No.

X
X
X
X
X
X
X
X
X
X
X
X
X
X

3360
3585
4050

330
380
470
556

300
351
465
530

230
310
415
505

145
230
345
465

60
145
270
392

2780
3000
3250
3580
3890

740
880
1000
1200
n

695
850
1000
1100
n

640
790
920
1050
1200

520
670
810
970
1100

420
560
700
900
1040

300
500
620
830
960

2400
2520
2830
3000
3300

1140
1270
n
n
n

1100
1250
1400
n
(Max. Safe

1000
840
700
1160
990
870
1380
1240
1100
1300
n
1400
RPM = 4000 @ 70F)

580
750
990
1210
1440

10

n (Max. safe RPM = 4800 @ 70F)


60
n
n
n
220
60
n
n
345
235
n
n

60
70

122 (RPM Max. = 4600 @70F)


300
180
n
500
350
250
710
575
465
860
750
630
280
490
780
1000
1300

n
200
600
790
1175

n
n
360
640
1010

75

90
100

130

Exhibited performance data are condensed. Each blower can be equipped


to perform at greater capacity with higher RPM and HP.

3 PHASE

1 SPD
S

2 SPD
M

1 SPD
T

2 SPD
R

Fan
RPM**

CFM @ Static Pressure (in. water)


8
10
14
16

F
G
144 H
J
K

1
112
2
3
5

X
X
X
X
X

X
X
X
X
X

X
X
X
X

2000
2110
2360
2510
2870

1120
1460
1710
2100
2500

770
1050
1300
1710
2300

420
774
1035
1440
2050

G
H
174 J
K
L

112
2
3
5
712

X
X
X
X
X

X
X
X
X
X

X
X
X

1680
1751
1900
2150
2400

1750
2150
2660
3400
3800

1200
1520
2140
2850
3600

720
1100
1600
2400
3100

G
194 H
J
K

1 2
2
3
5

X
X

X
X
X
X

X
X
X
X

1446
1504
1618
1822

1975
2350
2850
3600

1250
1650
2250
3100

700
1100
1700
2600

H
J
224 K
L
M

2
3
5
712
10

X
X

X
X
X
X
X

X
X
X

1220
1300
1430
1585
1720

2750
3500
4550
5220
5600

1800
2680
3800
4670
5400

1100
1800
3000
4100
4950

J
K
264 L
M
N

3
5
712
10
15

X
X
X
X
X

X
X
X

1070
1150
1270
1375
1490

3850
5200
6300
7100
8000

2700
3950
5300
6340
7200

1700
3000
4300
5280
6800

2200
3400
4500
6050

K
L
294 M
N
P

5
712
10
15
20

X
X
X
X
X

970
1060
1130
1250
1320

6030
7400
8400
9800
11000

4400
6000
7260
9100
10000

2900
4600
5900
7800
9200

2080
3400
4700
6678
8480

HP

Ship
Wt.
Lbs.

CFM @ Static Pressure (in. water)


Fan
RPM**

NOT AVAILABLE

HP

1 PHASE*
1 SPD 2 SP
S
M

NOT AVAILABLE

Compact
Model
No.

500
775
1200
1720
635
1250
2050
2750

517
950
1530

518
1200

880
1750
2440

1100
1800

18

22

(Max. RPM @ 70F = 4600)

180

1020

225

800

430

(Max. RPM @ 70F = 3745)

235

760
1600

330

1300

750

(Max. RPM @ 70F = 3114)


600
1250
2100

800
1700

950

1750
2750
3600

1800
2700

1300
2700
3720
5250

1240
2400
3950

2500
3800
5700
7300

2100
3940
5460

365
420

(Max. RPM @ 70F = 2635)


1120
2300
3350
4200

Ship
Wt.
Lbs.

1310
2230

1850

920

500

580

(Max. RPM @ 70F = 2280)

635

1760
3380

720

2860

1736

(Max. RPM @ 70F = 1995)

890

3180
4700

990

2500
4100

2600

**Fan RPM listed will result in CFM shown @ 4" S.P. Other CFM exhibited are maxima at corresponding S.P. and motor HP, and will require other RPM.
One winding
See page 10 for special motors. *120v or 230v 1 See page 10 for 208v. 1 (X) Available models
AMCA Spark Resistant Options
ACCESSORIES
Model

Drive
Cover

Vib.
Isolators

Drain
Fitting in
Housing

Bolted
Access
Door

Bare
Blower

TYPE C
Spark
Resist.

Heat
Slinger

Chemical
Resistant
Coating

Inlet
Flange

Outlet
Flange

Disc.
Swich

85
106
126

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

*
*
*

X
X
X

X
X
X

X
X
X

144
174
194

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

224
264
294

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

*Models 85, 106 and 126 are not available as Type C. They are avail. as Type B

34

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

See p. 38 for coatings. Welded to housing (X) Available accessories

CATALOG #37
www.centralfan.com

TYPE B: Blower equipped with


non-ferrous wheel and shaft ring.
(Not suitable for abrasives or
200F plus. Use Type C.)
TYPE C: A spark-resistant alloy
buffer attached to the housing
interior adjacent to the wheel front
and back and a buffer at the housing shaft opening. Suitable to
600F w/slinger. (Series 20 only)

Dimensions p. 35

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

NEW YORK
GEN. INDUSTRIAL
BLOWER
ARR. 10
LS WHEEL
(STEEL)
L, M, & D ARE OUTSIDE DIMENSIONS

DIMENSIONS (Inches)

OUTLET

INLET

OUTLET

Size

144
174
194
224

1512
1712
2114
2512

1012
1258
14
1612

1118
1318
16
1878

814
1018
1014
13

938
1118
1178
14

12
1412
18
2114

1014
1214
1378
1638

30
3418
3638
4138

158
158
318
318

212
3
312
4

9
11
11
13

778
912
934
1034

20
22
22
26

1978
2178
3378
3878

264
294
334
364

28
3212
3912
3912

1812
21
23
2512

2134
2458
2738
3014

15
1678
1834
2034

1618
1814
2038
2212

2412
2734
3078
3418

1878
2138
2378
2638

4412
48
5318
56

418
418
418
514

412
512
6
6

15
17
19
21

1238
14
1558
1714

26
2678
2978
30

4112
44
4858
5038

Size

Shaft
diameter

144
174
194
224

6
612

578
658
714
814

1638
1838
1738
2038

738
878
938
1078

612
8
814
934

8
912
1014
1134

1034
1318
15
1758

16
1914
2258
2658

1112
1334
17
20

934
1112
13
1514

1716
1716
11116
11516

264
294
334
364

778
858
938
1014

938
1018
11
1178

1978
2034
2334
2334

1214
1358
16
16

11
1134
14
14

13
1434
17
17

2014
23
2534
2812

3038
3438
3818
4218

23
2618
2914
3214

1712
1978
2238
2458

11516
11516
2316
2316

Keyway

8 x 316
8 x 316
3
8 x 316
1
2 x 14
1
2 x 14
1
2 x 14
1
2 x 14
1
2 x 14

Base
holes

16
16
9
16
9
16
3
4
3
4
3
4
3
4

NEW YORK COMPACT G.I. BLOWER NICKELALUMINUMBRONZE RADIAL WHEEL


ARRANGEMENT 9

DIMENSIONS (Inches)
OUTLET
Model
85
106
126

INLET

D*

1012
1012
1212

6
712
812

638
778
10

458
558
7

538
658
712

678
812
1114

578
714
834

17
19
2218

Dimensions should not be used for construction unless certified.

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

OUTLET
L*

M*

5
6
8

358
558
558

1014
1014
1258

R
338
438
4

**Angular discharge dimensions.


CATALOG #37
www.centralfan.com

a**

b**

c**

d**

Shaft
Dia.

6
6
1012

614
614
818

634
634
858

614
734
938

918
1114
1378

658
8
1058

558
634
818

1
1
1

See figure above.

*D,. L and M are outside dimensions.

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

35

GENERAL-PURPOSE
FUME EXHAUSTERS
Corrosion-Resistant resin construction for use in severe chemical environments

Fiberglass reinforced plastic construction


For severe corrosive fumes and aerosols
Efficient backwardly inclined wheel
Blower discharge rotatable
Standard CW wheel rotation is stock unit
Flanged outlet-slip inlet
250F max. operating temperature

WEATHER/DRIVE COVER STD.

STANDARD MOTORS ARE ODP.


SINGLE PHASE
Model
No.
C
D
E
GFE12 F
G
H
J
D
E
F
GFE15 G
H
J
K
E
F
G
GFE18 H
J
K
L
M

HP
1

3
2
4

1
3

1
112
2
3
1

2
3
4
1
112
2
3
5
3

1
112
2
3
5
712
10

CCW Rotation
(special order
for CCW units)

NOTE: Sizes 24, 30 & 36 are also available with several


week lead time.
(See page 37 for other plastic blowers.)

CW-UB (stock unit)

SEE PAGE 10 FOR SPECIAL MOTORS.


THREE PHASE

2" S.P.

CFM

1 Speed
S

2 Speed
M

1 Speed
T

2 Speed
R

Blower
RPM

O.V.
FPM

X
X
X
X
X
X
X

X
X
X

X
X
X
X
X
X
X

X
X

1846
2197
2560
2925
3315
3506
3506

1600
1700
2400
2800
3200
3400
0

1360
1700
2040
2300
2720
2890

1020
1400
1800
2100
2500
2800

765
1125
1530
1825
2300
2650
2890

850
1275
1600
2100
2450
2720

X
X
X
X
X
X
X

X
X
X

X
X
X
X
X
X
X

X
X
X
X

1550
1820
2090
2285
2500
2950
3195

1400
1700
2000
2200
2400
3000
3200

1750
2150
2450
2850
3200
3750

1400
1806
2125
2600
2900
3550
4128

1050
1525
1875
2400
2800
3300
3870

645
1200
1550
2100
2500
3100
3612

X
X
X
X
X
X
X

X
X

X
X
X
X
X
X
X
X

X
X
X
X
X
X

1220
1350
1575
1715
1975
2385
2638
2638

1600
1900
2300
2500
2900
3600
4000
0

3150
3600
4300
4800
5600
6900

2500
3000
3800
4400
5100
6500
7680

1950
2500
3300
4000
4800
6200
7300

(See page 10 for other motors.)

Optional set of vibration isolators available.

Static Pressure - inches of water


1
112
2
3

(10" S.P. Max.)


5
6

Approx.
Ship
Wt.

3800RPM Max @ 70F

150

850
1200
1700
2150
2550

800
1350
1750
2210

950
1400
2040

1100
1700

220

3315 RPM Max. @ 70F


950
1600
2050
2700
3354

1100
1600
2400
3096

1100
1950
2838

200

600
1550
2322

260

2900 RPM Max. @ 70F


1920
2880
3500
4400
5850
7000
7680

1900
2650
3750
5150
6450
7296

1800
3000
4600
5900
6912

2300
4000
5400
6528

290

3400
4650
6144

350

(X) Available models

( )
SLIP
INLET

Tolerance 18"

O.D. of inlet collar. Slip inlet only

36

Size

C*

12
15
18

918
1118
1358

1334
1678
2034

13
16
1912

3418
3858
4134

E
812

912
1034

Inside dimensions

*Outside dimensions

25
28
2938

1512
1712
2114

1414
1718
2038

934
12
1358

12
1458
16

1214
1458
1738

1318
1618
1912

3212
3612
3834

534
634
814

Shaft
Dia.

Base
holes

Bare
fan
weight

Open

TE

135
170
240

184T
215T
215T

184T
215T
215T

Size

12
15
18

678
878
934

1638
1738
1738

738
878
938

612
8
814

8
912
1014

1312
1512
18

1818
2114
2518

12
14
1658

1658
1934
2334

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

CATALOG #37
www.centralfan.com

1316
1716
11116

8
5
8
5
8

Maximum
motor frame

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

Lab Blowers
DIRECT DRIVE
SEE PP. 36, 38 FOR FRP BELT DRIVEN BLOWERS AND A
BRIEF LISTING OF SOME CORROSIVE VAPORS AND
PROTECTIVE COATINGS FOR METALS.

CCW-UB
Model AA, A

Lab blowers for corrosion resistance where metal blowers with or without protective coatings prove unsatisfactory.
Standard motors are ODP and not exposed to ducted fumes through blower. Max. temp. - 140F.
Model AA - Polypropylene wheel and PVC housing CCW-UB or CCW-TH
Model A - Polypropylene wheel and FRP housing CCW rotation - any disch.
NOTE: When strong oxidizing acids (nitric, sulfuric, chronic) are present use Model A with PVC wheel
PVC wheel is not suitable when vapor phase solvents are present, however.

Model
AA
A

HP
1

6
3

RPM
1725
1725

*1Phase
1 SPD 2 SPD
S
M
X
X

3 Phase

Motor

Cover

X
X

X
X

250
1100

X
X

DO NOT EXPOSE
THESE BLOWERS TO
PERCHLORIC ACID.
Shp.

CFM @ S.P.
1

112

Wt. Lbs.

180
995

800

500

30
50

225
1025

(X) Available models

*1 X.P. models available.

Dimensions

INLET

OUTLET

Model

A, in.

B, in.

C, in.

D, in.

E, in.

F, in.

G, in.

J, in.

K, in.

AA
A

558
912

658
714

334
412

512
8

9
1012

7
714

1312
1714

11
1518

412
8

Belt Drive Industrial PVC Blowers


Corrosion Resistant Radial Blade Blower
See page 38 for summary
of chemical activity
*NOTE: SPECIFY
CHEMICAL SUBSTANCE
& OPERATING TEMP.

AMCA CERTIFIED

SOLID POLYVINYL CHLORIDE HOUSING

Clockwise Rotation
Upblast Discharge
ARR. #9

100% corrosion Resistant to most inorganic chemicals*


Non-flammableSelf extinguishing
Operation to 150F
Electrical Insulator
Drain
Steel Reinforced Wheel
Belt and shaft guard standard
See p. 36 for FRP blowers

BELT DRIVE WITH TEFC MOTOR*

Model
No.

HP
1

3
2
3
4

C
D
PVC10 E
F
G

1
112

E
F
PVC14 G
H
J

1
112
2
3

F
G
PVC17 H
J
K

1
112
2
3
5

Wheel
Dia.
1012

O.V =
CFM
0.196
14
O.V. =
CFM
0.349
1712
O.V. =
CFM
0.545

Blwr.
RPM
@ 1"

1
3
Phase Phase
S
T*

DIMENSIONS

CFM
Static Pressure (inches water)
1

400
550
700
800
950

300
450
600
700
850

200
350
500
650
800

250
450
550
750

350
500
650

Approx.
Ship
Wt.
Lbs.

1829
2157
2390
2632
3013

X
X
X
X
X

X
X
X
X
X

500
650
750
850
1000

1510
1660
1910
2068
2393

X
X
X
X

X
X
X
X
X

1050
1200
1450
1600
1900

900 700 500


1050 900 700 550 400
1300 1150 1000 850 700 550
1450 1350 1200 1050 950 800
1750 1650 1550 1400 1300 1000

220

1175
1225
1442
1625
1709

X
X
X

X
X
X
X
X

1550
1850
2100
2450
2600

1250
1600
1850
2250
2600

260

*See p. 10 for special motors including 2-speed


PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581

(X) Available models

900
1350
1600
2050
2600

600
1050 800
1350 1100 900 650
1850 1650 1400 1200
2500 2300 2100 1900

175

10
A
B
C
D O.D.
E
F
G
J
K O.D.
L
M
N
P
R Max.
S Max.
T
V

10 2
9116
81516
6
4
11
14
17
6
758
1234
1334
15
1812
1412
934
1316

Model
14
1

14 4
12
101516
8
5
14
16
18
8
9916
1434
16
1714
2312
16516
1212
1316

17
1714
141516
1358
10
6
17
17
19
10
1118
1534
1912
2034
26
1834
1512
1716

Vibration isolators available

CATALOG #37
www.centralfan.com

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

37

Caution: Use these data as a guide only at 70F.


Consult the chemical mfr. for complete data.

CHEMICAL RESISTANCE OF
POLYVINYL CHLORIDE (PVC) & VINYL ESTER (FRP)
PVC provides FAIR-EXCELLENT protection to base metals exposed
to the following chemicals at room temperature:
Acetic acid (dilute)
Alcohol-methyl ethyl
Aluminum chloride
o Aluminum flouride
Aluminum hydroxide
Aluminum nitrate
Aluminum sulphate
Alum
Ammonia gas (Dry)
Ammonium chloride
Ammonium carbonate
o Ammonium hydroxide
Ammonium nitrate
Ammonium sulphate

Aqua regia
Barium carbonate
Beer
Benzoic acid
Calcium carbonate
Calcium chloride
Calcium nitrate
Calcium sulphate
Caustic
Chlorine
Chromic acid
Citric acid
Copper sulphate
Crude oil
Ethyl alcohol

Does not actively corrode bare aluminum

Ethylene glycol
Ferric chloride
Ferric nitrate
Ferric sulphate
o Flourine
o Formaldehyde
o Hydrochloric acid
Hydrogen peroxide
Hydrogen sulphide
Kerosene
Lead acetate
Magnesium carbonate
Magnesium chloride
Magnesium sulphate

Mineral oil
Naptha
Nitric acid (dilute)
Nitrous oxide
Oxygen
Perchloric acid (dilute)
Phosphoric acid
Photo solutions
Plating solutions
Propane
o Potassium hydroxide
Soda ash
Sodium chloride
Sodium cyanide
Sodium hydroxide

Sodium nitrate
Sodium sulphate
Stannous chloride
Sulphuric acid (dilute)
Tannic acid
Trisodium phos.
Urea
Water-salt
Zinc chloride
Zinc sulphate

o Will attack glass in FRP or Vinyl Ester

PVC is ATTACKED to the degree that it does NOT provide adequate protection
against the following chemicals at room temperature:

*
o*
*
*
*
*
o*

Acetone
Alcohol-Amyl, Benzyl
Ammonia (liquid)
Ammonium flouride
Ammonium phosphate
Amyl acetate
Amyl chloride
Aniline

*
*

*
*

Asphalt
Benzene
Bromine
Butane
Butyl acetate
Carbon tet.
Chloroform
Creosote
Esters

Does not actively corrode bare aluminum

o
*

*
*
*
o*
*

Ethers
Ethly acetate
Ethylene oxide
Formic acid
Gasoline
Heptane
Hexane
Hydrogen phosphide
Hydroflouric acid
Iodine

Use 316 stainless

* Use PVDF

Ketones
Methyl-Ethyl ketone
Methylene chloride
* Naphthalene
Nitric acid (anhyd.)
o* Phenol
Phosgene
* Propyl alcohol
* Sodium bisulphate
* Sodium nitrite
* Sodium peroxide

* Sodium acetate
* Sodium phosphate
* Stearic acid
Sulphate liquors
* Sulphur dioxide (wet)
* Toluene
o* Trichlorethylene
* Turpentine
Vinyl acetate
* Xylene

o Will attack glass in FRP or Vinyl Ester

Coatings Summary: (Central Fan will apply the following coatings.)


PVC-Sprayed, air dryed, multilayer coatings have good-to-excellent resistance to most acids, alkalies and marine exposures. Coatings are flexible,
fairly durable, and good to 150F. The most commonly used protective coating. Unsuitable in most vapor phase organic solvents.
Eisenheiss-Synthetic polyester resin which is sprayed, air dryed in multilayer coatings providing tough impermeable coatings good to 150F.
Chemical resistance similar to PVC except notably a slightly better performance when exposed to tricholorethylene, benzene, carbon tet., or gasoline. Does not perform well in hydrogen peroxide.
Heresite-A sprayed phenolic resin coating which provides good resistance to most common solvents, organic and inorganic acids. Not
recommended for caustics, alkalies, and oxidizing agents. Good to 120F. Affords fair resistance to methyl ethyl ketone, methylene chloride,
trichlorethylene.
Epoxy-One of the most durable all-purpose coatings which withstands reasonable abrasion and most chemicals.
Baked epoxy-(Factory applied by Peerless on all blowers) effectively protects carbon steel surfaces from normal atmospheric conditions. Is attacked
by acids, alkalies, and certain solvents. Can provide effective undercoating. CENTRAL FAN DOES NOT APPLY BAKED EPOXY COATINGS.

NOTE: BECAUSE OF THE INHERENT FRAGILITY OF ALL COATINGS, NO EXPLICIT WARRANTY OF SERVICEABILITY CAN BE MADE.
BLOWERS: Rigid PVC has good all-around corrosion resistance and is usually the economic material of choice. However, PVC becomes brittle at sub-zero temperatures and loses its strength above 150F. Thus, steel reinforcement is used in PVC blower wheels. Do not use FRP above 250F, or PVDF above 180F.
All are spark resistant (electric insulator). Graphite impregnation into FRP can make it conductive to control static electricity. UV radiation (direct sun) will
destroy polypropylene. Although slightly more in initial cost, FRP blowers prove to be more economical where the environment is severe and maximum durability is desired. Polyvinylidene (PVDF) will withstand inorganic acids and bases, organic acids, alcohols, aliphatic and aromatic hydrocarbons and halogenated solvents and halogens (except fluorine).

38

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

CATALOG #37
www.centralfan.com

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

Isolators for Vibration and Noise Control


The most effective vibration and noise control is obtained when the isolator deflects up to its maximum limitwithout exceeding that maximum deflection.
For proper selection:
1. Equipment weight - greater deflection (up to max.) provides maximum isolation
2. Equipment RPM - lower than 1200RPM use springs for maximum isolation (Higher RPMs use rubber regardless of substructure)
3. Equipment Location(a)Rigid sub-structure-use rubber or springs
(b)Flexible sub-structure-use springs (such as on upper levels of building)
Model
Isolator

Color

Cap
lbs.

RD
RD
RD
RD
RD

Blue
Red
Blue
Red
Black

35
70
135
240
375

.40
.40
.50
.50
.50

FDS-35
FDS-70
FDS-120
FDS-220
FDS-370

Blue
Green
Gray
Brown
Orange

35
70
120
220
370

FRS-35
FRS-70
FRS-120
FRS-220
FRS-375

Blue
Green
Gray
Brown
Orange

SL-35
SL-70
SL-120
SL-220
SL-370

Fig.

Max. Defl.
In.

Spring
O.D.

Dimensions (in.)
A

.
.
.
.
.

1.75
1.75
2.37
2.37
2.37

3.13
3.13
3.87
3.87
3.87

.85
.85
1.25
1.25
1.25

5
16
5
16
3 8
3
8
3
8

1.25
1.25
1.75
1.75
1.75

2.37
2.37
3.00
3.00
3.00

.34
.34
.34
.34
.34

1.52
1.36
1.18
1.10
1.00

1.75
1.75
1.75
1.75
1.75

2.63
2.63
2.63
2.63
2.63

2.63
2.63
2.63
2.63
2.63

3.50
3.50
3.50
3.50
3.50

.62
.62
.62
.62
.62

3.88
3.88
3.88
3.88
3.88

3
8
3
8
3
8
3
8
3
8

.
.
.
.
.

35
70
120
220
370

1.52
1.36
1.18
1.10
1.00

1.75
1.75
1.75
1.75
1.75

3.0
3.0
3.0
3.0
3.0

4.75
4.75
4.75
4.75
4.75

5.0
5.0
5.0
5.0
5.0

.50
.50
.50
.50
.50

5.0
5.0
5.0
5.0
5.0

3.75
3.75
3.75
3.75
3.75

.44
.44
.44
.44
.44

Blue
Green
Gray
Brown
Orange

35
70
120
220
370

1.52
1.36
1.18
1.10
1.00

1.75
1.75
1.75
1.75
1.75

2.12
2.12
2.12
2.12
2.12

6.12
6.12
6.12
6.12
6.12

3.50
3.50
3.50
3.50
3.50

3
8
3
8
3
8
3
8
3
8

4.00
4.00
4.00
4.00
4.00

5.63
5.63
5.63
5.63
5.63

.31
.31
.31
.31
.31

RHD-35
RHD-75
RHD-120
RHD-170

Blue
Red
Green
Black

35
75
120
170

.40
.40
.40
.50

.
.
.
.

2.25
2.25
2.25
3.00

2.0
2.0
2.0
2.25

3.0
3.0
3.0
4.5

.421
.421
.421
.656

1.37
1.37
1.37
1.87

.375
.375
.375
.625

.
.
.
.

SH-35
SH-70
SH-120
SH-220
SH-370

Blue
Green
Gray
Brown
Orange

35
70
120
220
370

1.52
1.36
1.18
1.10
1.00

1.75
1.75
1.75
1.75
1.75

3.69
3.69
3.69
3.69
3.69

2.25
2.25
2.25
2.25
2.25

5.25
5.25
5.25
5.25
5.25

.88
.88
.88
.88
.88

3.00
3.00
3.00
3.00
3.00

.
.
.
.
.

.
.
.
.
.

SRH-35
SRH-70
SRH-120
SRH-220
SRH-370

Blue
Green
Gray
Brown
Orange

35
70
120
220
370

1.55
1.42
1.29
1.30
1.33

1.75
1.75
1.75
1.75
1.75

3.69
3.69
3.69
3.69
3.69

2.25
2.25
2.25
2.25
2.25

7.38
7.38
7.38
7.38
7.38

.75
.75
.75
.75
.75

3.00
3.00
3.00
3.00
3.00

1.48
1.48
1.48
1.48
1.48

.
.
.
.
.

ARS-30
ARS-70

(For VAV)
Boxes

30
70

.50
.50

.
.

4.75
4.75

2.19
2.19

.50
.50

.27
.27

.
.

.
.

.
.

35
70
135
240
375

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

CATALOG #37
www.centralfan.com

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

39

Centrifugal Roof Exhausters


Direct Driven
All aluminum construction - compact design
A non-overloading, aluminum wheel
Quiet, vibration free motor mountings
Motor outside exhaust air stream, auto thermal, ODP
Bird screen
Disconnect switch
Galvanized steel frame for strength

Roof
Model

HP

120v 1 Phase
3 Phase
1 Speed Var. Sp. 1 Speed
S
M
T

PRN80
2.0 Amps

X(v)

PRN100
3.0 Amps

X(v)

PRN110
3.0 Amps

10

1750 RPM
120v 1
XP Motor
SX

12"
Ht.
Curb

Drop-in
Shutter

B9.

C1312

6 HP

B12

C1512

B12

C1512

B16

.
C2012

B16

C2012

10

10

X(v)

PRN126
3.0 Amps

X(v)

PRN145
6.3 Amps

X(v)

6 HP

4 HP

2 HP

RPM

Sones
@ 14

B
9
1314
1638

C
1834
2118
2734

E
378
478

328

248

*1550

5.8
4.0
3.0

770
650
520
430

690
550
410
270

610
450
210

520
280

380

11.3
7.6
4.7

1090
910
740
600

990
790
590
420

890
670
400

780
510

650
270

12.0
9.0
6.6

1760
1410
1140

1670 1560 1450 1320 1040


1290 1150 980 800 270
980 790 540 150

14.5
10.7
7.6

2540
2030
1640

2420 2300 2180 2060 1780 1440


1880 1730 1580 1400 920
1460 1270 1030 710

1300
1050
850

*1550
1300
1050
860

*1625
1300
1050

*1625
1300
1050

Shutter
O.D.
9
12
16

18 gauge galv. steel


fiberglass insulation
neoprene pad
continuous welds
sturdy shutter shelf
self flashing
Standard height = 12"
(other heights available)

Curb
O.D.
I.D.
1212
912
1
15 4
12
20
1634

24

27

210
27

680
43

46

Dimensions

Curb
Model
No.

O.D.

I.D.

C1312
C1512

1212
1514

914
12

8
10

18
21

C1912
C2012

1812
20

1514
1634

1312
1434

26
31

C2412
C2812

2312
2712

2014
2414

1814
2214

34
39

C3212
C3412

3112
3312

2814
3014

2614
2814

43
46

C3612
C3812

3512
3712

3214
3414

3014
*

48
50

C4012
C4312

3912
43

3614
3934

3414
3734

52
56

C4612
C4912

4512
49

4214
4534

4014

65
69

C5512
C6112

55
61

5134
5734

Ship
Wt.

*
*
*
* No shelf

CURB ADAPTERS**
Model
No.

Pitched curbs are special order.

CURB ADAPTERS
Sturdyweather tight.
Continuous welds.
18 ga. galv. steel
Adapter permits equal (based on performance) fan
replacement without disturbing existing roof curb.
**Many other sizes not shown are in stock.
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

382

ROOF FAN CURBS AND ADAPTERS

40

9.0

DIMENSIONS
A
1312
16
21

*1550

*Maximum RPM shown obtained with the standard one speed motor. For all other RPMs add solid state speed controller
(v) Variable speed w/control. Chemical resistant coating available (X) Available models
Because of 1725 RPM XP motor, the CFM shown will be increased proportionately.
Expl. Proof motors are single speed only. Disc. sw. extra (Not installed) See p. 10

Model
PRN 80
PRN 100, 110
PRN 126, 145

Ship
Wt.
lbs.
(Fan)

CFM
Static Press. (in. water)

CATALOG #37
www.centralfan.com

Dimensions
A

CA 1815
CA 1855
CA 1915

18
1812
19

1512
1512
1512

CA 2015
CA 2118

2012
21

1512
1812

CA 2218
CA 2220

22
22

1812
2012

CA 2515
CA 2518
CA 2520

25
25
25

1512
1812
2012

CA 2820
CA 2823

28
28

2012
2312

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

75
80

CENTRIFUGAL EXHAUSTERS
FEATURES
New, quiet, high efficiency PV models

Heavy gauge aluminum housings

Non-overloading aluminum impeller

Performance certified to 2" static press.

Prelubricated, sealed bearings

Motor and drive out of exhaust stream

Bird screen

Welded 18 ga. galv. insulated curb std.


curb ht. = 12" See p. 40 for curb detail.

ALUMINUM IMPELLER
SINGLE PHASE*
Model
No.
PV75 A
B
A
PV100 B
C
A
PV120 B
C
B
PV135 C
D
C
PV150 D
E
B
C
PV165 D
E
F
D
E
PV180
F
G
D
E
PV200 F
G
H
D
E
PV240 F
G
H

HP
1

6
1
4
1
6
1
4
1
3
1
6
1
4
1
3
1
4
1
3
1
2
1
3
1
2
3
4
1
14
3
1
2
3
4
1
1

2
3
4
1
112
1

2
3
4
1
1
1 2
2
1

2
3
4
1
1
1 2
2
3

3 PHASE

1 Speed 2 Speed 1 Speed


S
M
T

BELT DRIVEN

CFM

2 Speed
R

12"
Curb Shutter

Static Pressure (inches H2O)


1
1
3
1
4
2
4

Fan
RPM

Sones
@ 14"

8.6
10.7

830
940

730
860

620
770

480
660

140
530

112

X
X

C2012

B16

1669
1909

X
X
X

X
X

X
X

C2012

B16

1625
1869
1993

9.1
12.5
14.6

1200
1400
1500

1100
1300
1400

850
1200
1300

550
1000
1200

300
700
1100

600

X
X
X

X
X

X
X

C2012

1300
1580
1750

7.8
10.9
13.4

1440
1750
1940

1270
1610
1810

1050
1450
1680

730
1270
1520

1020
1345

750

X
X
X

X
X
X

X
X
X

C2012

B16

1480
1616
1823

11.7
13.6
17.1

2000
2200
2500

1800
2000
2300

1600
1800
2200

1200
1600
2000

900
1300
1800

X
X
X

X
X
X

X
X
X

X
X

B20

1185
1365
1555

11.2
14.1
17.6

2500
2870
3270

2240
2650
3080

1950
2400
2870

1610
2130
2660

1170
1830
2410

X
X
X
X
X

X
X
X
X
X

X
X
X
X
X

X
X
X

B20

975
1074
1244
1456
1584

9.1
11.4
15.7
19.2
21

2700
3000
3400
3900
4200

2200
2500
3000
3600
3900

1700
2100
2700
3300
3700

1100
1600
2300
2900
3400

X
X
X
X

X
X
X

X
X
X
X

X
X
X
X

B24

830
940
1050
1185

11.7
15.6
19.7
22.0

4340
4920
5490
6200

3800
4440
5060
5800

3080
3920
4600
5430

1930
3100
4030
5010

2020
3250
4440

X
X
X
X
X

X
X
X

X
X
X
X
X

X
X
X
X
X

B24

798
904
1000
1133
1250

10.9
13.9
16.7
20
23

4500
5100
5700
6500
7100

3900
4600
5200
6000
6700

2900
3700
4600
5500
6300

1900
3000
3800
5000
5800

1400
2100
3200
4200
5200

X
X
X
X
X

X
X
X

X
X
X
X
X

X
X
X
X
X

657
758
856
977
1033

10.4
13.7
17
21
23

5900
6700
7400
8500
8800

4800
5800
6700
7800
8300

3400
4600
5600
6900
7800

2200
3300
4500
6100
7200

X
X

X
X
X
X
X

X
X
X
X
X

583
646
749
814
834

15.5
18
21
24
25

8800
9800
11000
12000
m

7400 5900
8400 7000
10000 8800
11000 10100
11300 10600

4000
5500
7400
9000
9900

X
X
X
X
X

X
X
X
X
X

443
515
571
658
731

13
16.1
18.7
23
27

12200
14000
15500
17600
19000

10000
12100
13700
16100
18100

E
F
PV300 G
H
J

1
1
1 2
2
3

X
X
X
X
X

F
G
PV365 H
J
K

1
112
2
3
5

X
X
X
X

C2412

C2412

C2812

C2812

C3412

C4012

C4612

B16

B30

B36

B42

Ship
wt.
lbs.
85

85

90
93
1300

400

97
111

730
1840

119
112

1800
2600
3200

1600
2400

1600

130
206

2870

227
207

3000
3800

2100

226
254

2400
3300
5000
6500

2600
4600

1000

274
360

3400
6000
7800
9200

5200
7500

3900

418

7500 4600 2700


10000 8200 5200
12000 10000 7900
14600 13000 11400 7300
17200 16200 15300 12800 10000

422

487

*Single phase 120v or 230v. See p. 10 for 208v 1 and other special motors. See p. 10 for other special motors. (X) Available models
Motor controls p.10
DIMENSIONS
12" CURB
SHUTTER

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

Model

ID

OD

PV 75
PV 100

21
21

2312
1
23 2

2334
3
23 4

2
2

20
20

1634
3
16 4

16
16

PV 120
PV 135

21
21

2634
2634

2912
2912

2
2

20
20

1634
1634

16
16

PV 150
PV 165

24
24

31
31

35
35

2
2

2312
2312

20 4
2014

20
20

PV 180
PV 200

28
28

3512
1
35 2

3912
1
39 2

2
2

2712
1
27 2

2414
1
24 4

24
24

PV 240

34

3812

4612

3312

3014

30

PV 300

40

37

53

3912

3614

36

PV 365

46

46

64

45

CATALOG #37
www.centralfan.com

OD

42

42

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

41

MEETS NATIONAL FIRE


PROTECTION ASSOCIATION
STANDARD NFPA 96

LISTED CLASSIFICATION
YZHW
SUBJECT 762

UL

BELT DRIVE

Centrifugal Upblast Ventilators for


Commercial Kitchen Exhaust Systems

BELT DRIVE

Roof and Wall Mounting


UL LISTED NFPA 96 COMPLIANCE AMCA CERTIFIED AIR & SOUND GREASE COLLECTOR & DRAIN
BIRD SCREEN ALUMINUM WHEEL & HOUSING PRELUBRICATED SEALED BEARINGS EXTERNAL WIRING BOX
IF NFPA 96 COMPLIANCE REQUIRED SEE NOTE BELOW

Model
No.

HP
1

4
3
1
2
3
4
C 13
D 12
PNU165RG E 34

B
C
PNU135RG D
E

1 PHASE
3 PHASE
1 Speed 2 Speed 1 Speed 2 Speed
S
M
T
R
X
X
X
X

X
X
X
X

X
X
X
X

X
X

F 1
G 112

X
X
X
X
X

X
X
X
X
m

X
X
X
X
X

X
X
X
X

D 12
E 34
PNU200RG F 1
G 112
H 2

X
X
X
X
X

X
X
X

X
X
X
X
X

X
X
X
X
X

X
X

X
X
X
X
X

X
X
X
X
X

E
F
PNU245RG G
H
J

1
112
2
3

X
X
X
X
X

F
G
PNU300RG H
Roof J
Only K

1
112
2
3
5

X
X
X
X

X
X
X
X
X

X
X
X
X
X

G
H
PNU365RG J
Roof K
Only L

112
2
3
5
712

X
X
X

X
X
X
X
X

X
X
X
X
X

1 phase 120v or 230v.

Curb
12"
Optional Fan
18" Shutter RPM

2012
2230
2565
2950

1774
2016
2380
2790

1527
1788
2187
2630

1282
1578
1992
2455

B24

1120
1287
1480
1632
1771

13.8
17.0
22.0
25.0
27.0

2936
3377
3881
4400
4708

2570
3064
3608
4100
4487

2196
2728
3323
3750
4277

1810
2417
3034
3390
4071

2063
2766
3050
3866

B24

948
1085
1194
1360
1496

14.0
17.2
21.0
26.0
28.0

4414
5052
5560
6328
6966

3746
4406
4924
5698
6332

3285
4064
4666
5548
6263

2664
3574
4216
5145
5897

1724
2994
3742
4752
5532

B30

725
797
913
1005
1150

15.3
17.5
21.0
24.0
27.0

5890
6474
7417
8164
9342

5188
5840
6863
7660
8900

4448
5185
6297
7150
8460

3588
4457
5706
6632
8010

B36

596
692
760
879
987

14.5
17.3
21.0
26.0
31.0

9541
10652
11615
13225
14622

7975
9515
10625
12450
14131

6373
8215
9575
11515
13619

5078
6910
8480
10225
13055

490
548
633
757
813

15.2
17.0
23.0
31.0
35.0

13750
15022
17503
20500
21692

11810
13500
15925
19390
20967

9914
11640
14350
18175
20210

7700
9575
12410
16750
19378

C2818*

C2812
C2818*

C3412
C3418*

C4012
C4018*

C4612

B42
C4618*

See page 10 for special motors and disconnect switches

*NFPA 96 Requires:
Min. curb height 18" (disch. > 40" above roof)
Fan-curb hinge assembly to allow cleaning fan and duct
500 FPM min. duct velocity
External grease trough
Prohibits duct damper (shutter)

B
2738

PNU165
PNU200
PNU245

28
28
34

26
1

31 2
1

36 4
1

Curb

6-34

1-2
3
5
712-10

Shutter

Wall Flange

OD

ID

OD

OD

Flange

2218

2312

2014

20

2312

2712

38
3

39 4
3

44 4
3

22 2
3

28 4
1

31 2
1

27 2
1

27 2
1

33 2
1

24 4
1

24 4

24
24

3112

3112

27 2
27 2

30

33 2

3712

30 4

PNU300

40

42 2

55 8

34 4

39 2

36 4

36

PNU365

46

46

66

4114

4512

4214

42

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

Ship
Wt.
120

1320
1960

1500

135
180

2066
2600
3300

2700

215
240

2457
3878
4807

2645
3918

275
290

3510
5060
6074
7556

2289
4780
6570

5346

340
415

5701
7125
9580
12444

8196
11262

9904

530
510

8473
10885
15479
18476

12450
16730

Single Phase
HP

3312

13815

620

Motor Disconnect Switches

(PNU245 max. size for wall mtg.)


#Requires smaller O.D. curb
(PNU245 max. size for hinge kit)

882
1333
1810
2290

112

(X) Available models

ACCESSORIES:
Curb hinge kit#
External grease trough
Wall mount flange

Dimensions
24

14.5
16.2
17.5
21.0

C2812

Model

1400
1550
1780
2050

C2418*

PNU135

CFM
Static Pressure (in. H2O)
3
2
4
1

B20

C2412

NOTE:

Sones
@ 14"

CATALOG #37
www.centralfan.com

Three Phase

1 Sp.

2 Sp.

1 Sp.

X
X
X

X
X

X
X
X
X
X*

*460V-550V only

2 Sp.
X
X
X
X

(X) Available

WALL MOUNT

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

43

Belt Drive

Centrifugal Upblast Ventilators


Roof and Wall Mounting

BELT DRIVE

Suitable for mounting on roof or wall applications


Exhausts air containing odors, fumes, grease etc.
Integral trough and drain allow for drainage of liquids
Bird screen
Pre-lubricated sealed ball bearings
Motor and drive assembly out of exhaust air
Heavy gauge, aluminum construction - non-overloading wheel
Welded 18 ga. galv. Insulated curb (std. 12" high) Special curbs page 40.

1 PHASE*
Model
No.
B
C
PNU8RF D
E

HP
1

4
3
1
2
3
4
1
4
1
3
1
2
3
4
1
3
1
2
3
4

3 PHASE

1 Speed 2 Speed 1 Speed 2 Speed


S
M
T
R
X
X
X
X

X
X
X
X

X
X
X
X

X
X

X
X
X
X

X
X
X
X

X
X
X
X

X
X

C
D
PNU165RF E
F 1
G 112

X
X
X
X
X

X
X
X
X

X
X
X
X
X

X
X
X
X

D 12
E 34
PNU200RF F 1
G 112
H 2

X
X
X
X
X

X
X
X

X
X
X
X
X

X
X
X
X
X

X
X

X
X
X
X
X

X
X
X
X
X

B
C
PNU135RF D
E

E
F
PNU245RF G
H
J

1
112
2
3

X
X
X
X
X

F
G
PNU300RF H
Roof J
Only K

1
112
2
3
5

X
X
X
X

X
X
X
X
X

X
X
X
X
X

G
H
PNU365RF J
Roof K
Only L

112
2
3
5
712

X
X
X

X
X
X
X
X

X
X
X
X
X

*1 phase 120v or 230v.

(X) Available models

12"
Curb

CFM
Static Pressure (in. H2O)
1
3
2
4
1

112

485
540
640
750

440
500
600
720

390
450
525
690

350
415
525
660

225
330
450
590

200
375
530

2012
2230
2585
2950

1774
2016
2380
2790

1527
1788
2187
2630

1282
1578
1992
2455

882
1333
1810
2290

13.8
17.0
22.0
25.0
27.0

2936
3377
3881
4400
4708

2570
3064
3608
4100
4487

2196
2728
3323
3750
4277

1810
2417
3034
3390
4071

2063
2766
3050
3866

948
1085
1194
1360
1496

14.0
17.2
18.2
21.0
24.0

4414
5052
5560
6328
6332

3746
4406
4924
5698
6615

3285
4064
4666
5548
6263

2664
3574
4216
5145
5897

1724
2994
3742
4752
5532

B30

725
797
913
1005
1150

15.3
17.5
21.0
24.0
27.0

5890
6474
7417
8164
9342

5188
5840
6863
7660
8900

4448
5185
6297
7150
8460

3588
4457
5706
6632
8010

3510
5060
6074
7556

B36

596
692
760
879
987

14.5
17.3
21.0
26.0
31.0

9541
10652
11615
13225
14622

7975
9515
10625
12450
14131

6373
8215
9575
11515
13619

5078
6910
8480
10225
13055

490
548
633
757
813

15.2
17.0
23.0
31.0
35.0

13750
15022
17503
20500
21692

11810
13500
15925
19390
20967

9914
11640
14350
18175
20210

7700
9575
12410
16750
19378

Fan
RPM

Sones
@ 14"

B20

2103
2315
2705
3131

11.1
12.6
16.1
19.9

530
600
700
800

B20

1400
1550
1780
2050

14.5
16.2
17.5
21.0

B24

1120
1287
1480
1632
1771

B24

Shutter

C2412

C2412

C2812

C2812

C3412

C4012

C4612

B42

See page 10 for special motors

44

Dimensions
A
B
C
24
2738 3312
24
2738 3312
28
26
38
28
3112
3934
1
34
36 4
4434
1
40
42 2
5538
46
46
66

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

D
2218
2218
2212
2834
3112
3414
4114

Curb
OD
ID
2312
2014
2312
2014
1
27 2
2414
1
27 2
2414
1
33 2
3014
1
39 2
3614
1
45 2
4214

Ship
Wt.
120

140
120

1320
1960

1500

135
180

2066
2600
3300

2700

215
240

2457
3878
4807

2645
3918

275
290

2289
4780
6570

5346

340
415

5701
7125
9580
12444

8196
11262

9904

530
510

8473
10885
15479
18476

12450
16730

13815

620

Motor Disconnect Switches

ACCESSORIES:
Curb hinge kit (Requires smaller O.D. curb. PNU245 max. size.)
External grease trough
Wall mount flange (PNU245 max. size for wall mtg.)
Chemical resistant coating
Model
PNU8
PNU135
PNU165
PNU200
PNU245
PNU300
PNU365

KITCHEN EXHAUST FANS


NFPA 96 AND UL YZHW #762
PAGES 42,43

Shutter
OD
20
20
24
24
30
36
42

CATALOG #37
www.centralfan.com

Wall Flange
OD
Flange
2312
2712
1
23 2
2712
1
27 2
3112
1
27 2
3112
1
33 2
3712

Single Phase Three Phase


HP

1 Sp.

2 Sp.

6-34

X
X
X

X
X

1-2
3
5
712-10

1 Sp. 2 Sp.

*460V-550V only

WALL MOUNT

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

X
X
X
X
X*

X
X
X
X

ROOF AIR SUPPLY


SIDE INTAKE
CONSERVES ENERGY IN MAKE-UP AIR SYSTEMS
Can be located on roof directly over kitchen exhaust hoods, reducing
cost of electrical hook-up, expensive insulated interior ducts and fittings.
May also reduce the number of roof penetrations required.

FEATURES
Easy on site addition of duct extension* to meet code requirements
for supply and exhaust separation
Permanent filters serviceable from exterior of unit.
Blower equipped with ball bearings with an operating temperature
range of -65 to +250F.
Latched top cover provides easy access to blower, motor and
drives.

Weather resistant finish of enamel paint on galvanized steel.


Permanent aluminum mesh filters mounted in intake hood (except
Model SIS-20)
SIS-20 has large drawer type filter section with screened inlet (not illustrated).
Large filter surface areas for efficient filtering (Intake velocities
do not exceed 600 FPM)

*Intake duct not supplied

Model
No.
B
C
D
SIS9
E
F
G

HP
1

4
3
2
3
4
1
1

1
1
1 2
1

3
C
1
2
D
3
SIS10 E
4
F 1
1
G 1 2
1
D
2
3
E
4
SIS12 F 1
1
G 1 2
H 2

4
E
F 1
1
SIS15 G 1 2
H 2
J 3

F 1
1
G 1 2
SIS18 H 2
J 3
K 5

H 2
J 3
SIS20 K 51
L 7 2
M 10

SINGLE SPEED*

12"

1 Phase 3 Phase
S*
T

Roof
Curb

X
X
X
X
X
X

X
X
X
X
X
X

X
X
X
X
X

X
X
X
X
X

X
X
X
X
X
X
X
X
X
X

X
X
X
X

X
X

X
X
X
X
X
X
X
X
X
X

X
X
X
X
X

X
X
X
X
X

Static Pressure (inches water)


Supply
Shutter

4"

2"

4"

1 2"

1"

CFM

RPM

HP

RPM

HP

RPM

HP

RPM

C2412 BS18

600
800
1200
1600
1800
2000

577
622
746
901
985
1072

.06
.10
.23
.46
.63
.84

785
809
899
1022
1092
1168

.11
.15
.30
.56
.73
.95

964
968
1032
1139
1200
1265

.16
.21
.38
.66
.85
1.08

1115
1108
1155
1295
1302
1362

C2812 BS22

800
1200
1600
2000
2400

525
600
701
810
925

.08
.18
.33
.58
.93

704
754
828
923
1029

.14
.26
.45
.71
1.09

874
881
945
1023
1118

.20
.34
.55
.85
1.25

C3212 BS26

1600
2000
2400
2800
3000
3400

497
551
614
685
721
792

.21
.34
.52
.77
.92
1.28

633
671
721
775
805
870

.31
.45
.66
.93
1.10
1.48

767
778
816
865
891
945

C3612 BS30

2000
2500
3000
3500
4000
4500
5000

384
409
444
486
533
584
637

.23
.36
.54
.78
1.09
1.50
2.01

508
527
521
577
610
649
692

.37
.53
.73
.99
1.32
1.74
2.25

C3612 BS30

4000
4500
5000
5500
6000
6500
7000
7500

378
402
428
456
485
515
546
578

.65
.85
1.11
1.41
1.77
2.18
2.67
3.22

464
484
505
527
551
576
602
630

C4312 BS37

5000
6000
7000
8000
9000
10000
11000
12000

374
419
464
512
562
614
667
720

.85
1.31
1.90
2.69
3.68
4.91
6.47
8.20

443
482
529
571
616
662
709
758

HP

2"

2 2"
RPM
HP

Ship
Wt.

RPM

HP

RPM

HP

.23
.28
.47
.77
.97
1.21

1346
1367
1377
1439
1483
1536

.36
.45
.65
.98
1.20
1.47

1573
1570
1618
1652

.62
.84
1.21
1.45

1743
1752
1784

.79
1.06
1.46

1013
997
1051
1118
1201

.27
.42
.66
.99
1.42

1299
1231
1234
1293

.41
.60
.87
1.25

1404
1433
1408

.56
.80
1.10

1555
1600
1584

.72
1.00
1.34

.42
.58
.80
1.10
1.27
1.68

884
886
905
945
969
1020

.55
.72
.95
1.26
1.45
1.88

1075
1083
1085
1099
1114

.82
1.04
1.29
1.61
1.81

1233
1245
1252

1.11
1.37
1.67

1371
1386

1.41
1.72

622
623
643
667
691
720
755

.37
.70
.94
1.24
1.58
2.01
2.55

721
717
723
744
769
792
819

.73
.88
1.14
1.48
1.87
2.32
2.86

871
883
878
881
898
922

1.10
1.35
1.58
1.94
2.41
2.95

988
1014
1019
1014
1017

1.46
1.84
2.15
2.47
2.95

1088
1121
1138

1.81
2.30
2.74

200

.93
1.15
1.40
1.72
2.10
2.54
3.05
3.63

537
553
572
592
669
635
658
682

1.22
1.49
1.78
2.10
2.47
2.92
3.44
4.05

620
617
632
650
669
690
711
733

1.60
1.80
2.14
2.52
2.92
3.37
3.89
4.49

780
774
757
756
770
787
806

2.57
2.85
2.97
3.29
3.79
4.36
4.94

893
900
899
883
870

3.29
3.83
4.28
4.72
4.72

987
999

3.97
4.63

345

1.17
1.69
2.36
3.21
4.26
5.53
7.06
8.88

513
539
576
618
663
708
753
799

1.53
2.08
2.80
3.72
4.85
6.19
7.78
9.64

581
597
625
662
704
748
793

1.92
2.50
3.26
4.23
5.41
6.84
8.51

701
710
724
748
780
818
861

3.66
3.45
4.25
5.29
6.57
8.10
9.90

797
812
821
835
857
887

3.66
4.50
5.38
6.45
7.79
9.40

879
899
910
920
934

4.50
5.55
6.60
7.72
9.10

84

110
104

130
140

173

267

387
670

800

*Single phase 120v or 230v

Damper spring return. (See p. 8.)


Supply damper is mounted in horizontal plane; opens downward with airflow.
See page 10 for special motors
All dampers are square. Model No. indicates size - nominal size minus 18".
Static pressure reduction on blowers designed for higher pressure could result in motor overload (X) Available models

Curb Cap
Model
SIS9
SIS10
SIS12
SIS15
SIS18
SIS20

Dimensions

A*

2438
2838
3238
3638
3638
4438

1938
2138
2458
2838
4212
49

1014
1138
13716
1578
1878
2434

11316
1318
1558
1858
2178
2434

6932
758
8116
812
714
91316

7116
812
938
734
6
14716

7116
812
938
12516
1112
5316

1914
2012
2538
31316
3558
3858

M
16916
18916
21916
251316
321116
35916

Z
2114
2534
3034
3312
4014
4512

*Inside dimension

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

CATALOG #37
www.centralfan.com

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

45

Exhaust Relief or Fresh Air Intake

Gravity Trimline Ventilators


LOW SILHOUETTE
Hood perimeter opening-to-throat area = 2:1
Inlet velocity at hood opening less than 650 FPM
to prevent snow intake
Welded, heavy (.080") aluminum
Bird screen
Optional powered fan supply or exhaust

OUTSIDE DIMENSION

Dimensions

Vent
Model

12"
High Curb

Intake
115v
Motorized
Shutter

O.D.

I.D.

Vent
Ship
Wt.

IV 1212
IV 1616
IV 2020

C2012
C2412
C2812

BM15L
BM20L
BM24L

B15
B20
B24

1300
2310
3500

1.0
1.8
2.8

20
24
28

21
28
35

7
9
11

1812
2312
2712

1514
2014
2414

37
46
74

IV 2424
IV 3030
IV 3636

C3212
C3612
C4312

BM28L
BM32L
BM39L

B28
B32
B39

5240
7870
11610

4.0
6.25
9.0

32
38
44

42
53
63

11
13
15

3112
3512
43

2814
3234
3934

79
116
140

Exhaust
Gravity
Shutter

Supply
CFM*
.18" S.P.

**Throat
Area
Sq. Ft.

Vent

12" Curb

*Max. supply for < 650 FPM (snow intake velocity) Max. exhaust. = 1.5X air supply
Outside dimension
Gravity damper will not operate as barometric damper.
**Throat dimensions equivalent to model number (X) Available models

ROOF FAN CURBS AND ADAPTERS


18 gauge galv. steel
fiberglass insulation
neoprene pad
continuous welds
sturdy shutter shelf
self flashing
Standard height = 12"
(other heights available)
Pitched curbs are special order.

Adapter permits equal (based on performance) fan replacement without


disturbing existing roof curb. Many other sizes not shown available.
Sturdyweather tight
Continuous welds.
18 ga. galv. Steel.

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

DIMENSIONS
M

Ship
Wt.

O.D.

I.D.

C1312
C1512

1212
1514

914
12

8
10

18
21

C1912
C2012

1812
20

1514
1634

1312
1434

26
31

C2412
C2812

2312
2712

2014
2414

1814
2214

34
39

C3212
C3412

3112
3312

2814
3014

2614
2814

43
46

C3612
C3812

3512
3712

3214
3414

3014

48
50

C4012
C4312

3912
43

3614
3934

3414
3734

52
56

C4612
C4912

4512
49

4214
4534

4014

65
69

C5512
C6112

55
61

5134
5734

*
*
*

75
80

*No shelf
CURB ADAPTERS

CURB ADAPTERS

46

Curb
Model
No.

CATALOG #37
www.centralfan.com

Dimensions

Model
No.

CA 1815
CA 1855
CA 1915

18
1812
19

1512
1512
1512

CA 2015
CA 2118

2012
21

1512
1812

CA 2218
CA 2220

22
22

1812
2012

CA 2515
CA 2518
CA 2520

25
25
25

1512
1812
2012

CA 2820
CA 2823

28
28

2012
2312

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

Lau Double Inlet Blowers


FORWARD CURVE - DOUBLE WIDTH WHEELS - BELT DRIVE
Low cost double inlet blowers with double width wheels for those applications not requiring duct to the inlet end.
Their compact design and quietness of operation make these blowers popular for residential and commercial
heating and air conditioning.
Belt driven for flexible choice of speeds and air outputs, with standard motors that are easy and economical to
replace if necessary.
CLOCKWISE OR CCW ROTATION - (facing motor shaft). Bottom horizontal discharge unless otherwise specified. Discharge position can be easily changed.
Long life bronze bearings - Oversized belt drive - True running balanced wheels. Furnished with soft rubber
vibration bushings. Use ball bearings for 3/4 HP or greater motor.
BARE BLOWER
(NO MOTOR DRIVE)
Model
Wt.
No.
Lbs

A9-6

17

A9-7

19

A9-9

22

A10-6

22

A10-8

23

A10-10

26

A12-6

37

A12-9

39

A12-12*

41

A15-9

50

A15-11

52

A15-15*

65

A18-13

90

A18-18*

100

See p.10 for special motors


Assembled & Tested Blower
(With motor and drive on blower)
Model
A
B
C
D
E*
F*
G*
H*

HP

1 1 Speed

1 2 Speed

3 1 Speed

X
X
X

X
X

X
X

X
X
X

X
X
X

X
X
X

112
2

X
X

X
X

6
1
4
1
3
1
2
3
4

*Use ball bearings

(X) Available models

DIMENSIONS
Model
Number
A
A
A
A
A
A
A
A
A
A
A
A
A
A

9-6 ACE
9-7 ACE
9-9 ACE
10-6 ACE
10-8 ACE
10-10 ACE
12-6 ACE
12-9 ACE
12-12 ACE
15-9 ACE
15-11 ACE
15-15 ACE
18-13 ACE
18-18 ACE

K
814
9316
1178
814
1012
1318
81316
1238
1534
121316
141116
1858
1738
2178

1014
1014
1014
1138
1138
1138
13716
13716
13716
1578
1578
1578
1878
1878

15716
15716
15716
1714
1714
1714
20716
20716
20716
2418
2418
2418
29316
29316

B
141516
141516
141516
1612
1612
1612
19516
19516
19516
2258
2258
2258
27
27

Shaft
Size

4
4
4
3
4
3
4
3
4
3
3
3

1
1
1
1
1
1
1
1

BLOWER PERFORMANCE
1

4" SP

CFM
400
600
800
1000
400
600
800
1000
600
800
1000
1200
1400
400
600
800
1000
1200
1400
600
800
1000
1200
1400
800
1000
1200
1400
1600
1800
600
800
1000
1200
1400
1600
1800
1000
1200
1400
1600
1800
2000
1400
1600
1800
2000
2200
2400
2600
1500
2000
2500
3000
3500
4000
4500
5000
2000
2500
3000
3500
4000
2000
2500
3000
3500
4000
4500
3000
3500
4000
4500
5000
5500
6000
3000
3500
4000
4500
5000
5500
6000
6500
7000

RPM
556
575
630
700
553
586
599
644
566
589
623
663
710
491
500
529
577
635
695
477
492
517
550
586
490
507
529
558
591
635
414
417
439
472
509
542
581
400
410
424
447
470
496
424
436
451
463
486
507
530
347
375
411
458
493
540
589
637
344
368
396
441
479
350
370
395
429
467
505
309
327
352
377
400
427
455
302
315
340
351
367
388
407
423
439

HP
.07
.09
.12
.18
.07
.09
.11
.14
.10
.12
.15
.19
.25
.06
.09
.12
.16
.21
.30
.06
.10
.12
.17
.21
.13
.16
.18
.22
.25
.32
.11
.11
.14
.18
.23
.30
.32
.11
.13
.15
.19
.23
.27
.16
.18
.22
.26
.30
.36
.42
.17
.25
.36
.52
.73
1.05
1.37
1.75
.21
.30
.41
.50
.84
.20
.27
.36
.49
.68
.88
.31
.41
.58
.70
.90
1.17
1.33
.28
.36
.48
.61
.74
.90
1.12
1.28
1.50

2" SP

RPM
783
769
794
845
807
790
793
813
788
787
803
828
863
704
686
697
724
765
813
700
693
690
727
734
700
693
705
718
739
763
593
577
586
602
623
647
677
566
563
566
575
580
600
574
579
587
596
609
623
638
472
483
503
534
564
605
648
690
459
467
487
512
543
480
488
504
524
552
579
415
423
435
448
463
483
502
414
418
427
437
449
463
476
492
508

HP
.11
.13
.16
.22
.09
.13
.16
.19
.14
.16
.20
.25
.32
.11
.13
.16
.21
.29
.38
.11
.14
.17
.23
.28
.20
.21
.26
.29
.34
.40
.18
.19
.22
.27
.32
.37
.43
.18
.21
.23
.27
.31
.37
.26
.29
.32
.37
.42
.47
.54
.24
.34
.46
.62
.87
1.22
1.58
2.05
.30
.40
.53
.73
1.00
.31
.40
.52
.67
.86
1.06
.52
.58
.73
.90
1.10
1.36
1.62
.47
.56
.65
.80
.96
1.13
1.36
1.60
1.87

4" SP

RPM
992
950
958
986
986
954
946
954
998
972
964
980
1005
872
841
838
854
880
918
863
836
829
836
847
859
843
841
847
863
883
735
712
708
712
726
744
765
714
697
688
689
695
705
700
702
704
711
718
728
740
582
576
590
608
633
667
703
745
562
563
573
590
611
595
592
598
610
626
647
497
500
506
514
527
541
557
505
503
505
511
521
531
542
556
571

HP
.15
.17
.21
.27
.14
.19
.22
.26
.20
.23
.27
.33
.40
.15
.16
.21
.27
.34
.45
.17
.18
.22
.30
.35
.28
.30
.33
.38
.43
.50
.24
.26
.30
.34
.39
.45
.55
.28
.29
.32
.36
.41
.48
.33
.37
.42
.47
.52
.58
.65
.34
.44
.60
.81
1.06
1.42
1.80
2.30
.42
.52
.67
.89
1.17
.45
.55
.67
.83
1.02
1.25
.64
.76
.92
1.11
1.38
1.60
1.89
.61
.71
.83
.99
1.19
1.42
1.67
1.88
2.20

1" SP
RPM
1156
1102
1092
1100
1133
1118
1097
1092
1148
1127
1109
1111
1123
1014
983
963
969
989
1017
1013
981
963
958
960
1002
977
967
968
987
991
852
835
812
811
820
832
851
828
815
800
794
791
795
816
809
811
812
817
823
831
666
657
665
680
702
729
761
800
654
652
654
663
679
695
682
679
685
695
712
570
571
576
582
590
599
613
593
585
581
583
589
596
606
616
629

HP
.19
.21
.25
.37
.19
.22
.31
.34
.25
.29
.33
.39
.47
.18
.21
.26
.31
.40
.52
.22
.25
.31
.35
.44
.37
.38
.42
.45
.53
.60
.30
.32
.36
.41
.47
.54
.64
.36
.38
.42
.45
.51
.57
.42
.47
.51
.56
.62
.69
.76
.43
.56
.72
.95
1.23
1.55
2.02
2.50
.52
.66
.82
1.05
1.32
.56
.69
.81
.97
1.17
1.44
.76
.94
1.13
1.37
1.54
1.85
2.14
.82
.93
1.06
1.22
1.43
1.66
1.94
2.20
2.52

*Ball bearings std.


PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581

CATALOG #37
www.centralfan.com

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

47

American

Coolair
BELT DRIVE UPBLAST AXIAL ROOF FAN

Heavy gauge steel construction with baked epoxy finish


Fiberglass butterfly dampers serve as skylight when not in operation
Unpainted galvanized steel windband
Magnetic latches prevent damper flap when fan is not in operation

SPECIAL ORDER MODELS JT AND HS

MODEL JBH

JT Model has motor & drive removed from air stream and accessible from roof.
HS model for heat & smoke removal. Continuous operation at 650F. Intermittent to 1200F
STD. Model JBH
Open Motor*

Model
No.

HP

1 Phase
S

3 Phase
T
X
X
X

Model JBH Performances


CFM
Static pressure (inches H2O)

12"
High
Curb

Fan
RPM

949
1048
1075

7901
8725
8950

6564
7537
7795

6860
7143

C4312

798
887
965
1113

11780
13094
14245
16430

9724
11255
12559
14969

10279
11692
14234

607
670
725
826

15425
17026
18423
20990

14082
15774
18688

14162
17417
15759
19534

E
JBH24 F
G

1
112

X
X
X

F
JBH30 G
H
J

1
112
2
3

X
X
X
X

X
X
X
X

F
JBH36 G
H
J

1
112
2
3

X
X
X
X

X
X
X
X

C4912

G
JBH42 H
J

1 2
2
3

X
X
X

X
X
X

C5512

533
579
659

20363
22121
25177

15703
18007
21857

H
JBH48 J

2
3

X
X

X
X

C6112

469
533

26870
30537

20378
25086

C3812

Sones
@5'

JBH
Ship
Wt.

31
38
40

240
242
282

26
31
36
48

315
335
340
362

23
27
31
38

367
385
395
412

27
31
38

470
475
500

29
35

620
640

5000
6489
7700
10727
13478
9000

15989
14000
17737
17000

21687

Min. CFM to yield O.V. = 1850 FPM prevents entry of rain during operation. Low speed operation (2-sp. motor) could allow PPT. entry
Two speed operation is therefore limited. *Special motors p. 10. (X) Available models

Note: Motor and drive assembled and tested on fan panel


Fan panel, dampers and windband are separate for ease of handling in shipping and site location.

SPECIAL ORDER MODELS JT-HS

STANDARD MODEL JBH

MODEL JBH

DIMENSIONS

Model
No.

JBH 24
JBH 30

32
38

2834
3358

38
44

32
38

1178
163/4

518
518

JBH 36
JBH 42

44
50

3358
3812

50
56

44
50

17
17

JBH 48

56

3912

62

56

17

48

MODEL JT

Model
No.

MODEL HS

DIMENSIONS

Model
No.

DIMENSIONS

JT 24
JT 30

32
38

5314
5814

38
44

3014
3614

28
28

3012
3412

HS 24
HS 30

57
57

518
518

JT 36
JT 42

44
50

6618
71

50
56

4214
4812

36
36

4158
4514

HS 36
HS 42

518

JT 48

56

71

62

5458

36

4834

HS 48

CENTRAL FAN CO., INC.


3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155

CATALOG #37
www.centralfan.com

F
18
18

67
78

14
38
30
14
44
36
SEE MODEL
JT
15
50
42
17
56
48

88

20

27

62

PHONE: (781) 393-4456


1-800-937-4326
FAX: (781) 396-4581

54

19
20