The following sections in this chapter describe the installation of software on the hardware platform for
your solution.
There are points in the procedures when your responses to prompts will depend on the disk drive size or
other particulars of your system. These are pointed out as you follow the procedures.
Table 2-1
Section
Page
Supported Platforms
15
31
32
32
34
36
37
43
45
46
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-1
Chapter 2
Supported Platforms
Table 2-1
Section
Installing Lights Out Management Software
47
50
51
54
55
55
Troubleshooting
Note
Page
57
Netra t 10x
57
57
For procedures on migrating to Solaris 8 and Cisco MGC 9.2(2) software, refer to Appendix 12,
Migrating to Solaris 8 and Cisco MGC 9.2 and Up.
Supported Platforms
This document describes the specific steps necessary to install the Solaris 8 Operating System software
and Solstice DiskSuite on the Netra t and Sun Fire platforms. The following platforms are supported:
Netra 240
Netra 440
Netra 120
Netra t1 100/105
Netra t 1120/1125
Netra t 1400/1405
Netra 20
18 GB
36 GB
73 GB
146 GB
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-2
OL-1150-15
Chapter 2
During the installation of the software package on the Netra t 112X machines, leave the
front panel open to prevent damage to the CD or machine because the CD-ROM drive will
automatically eject the CD.
Note
The Cisco PGW 2200 PSTN Gateway (hereafter referred to as Cisco PGW 2200) is the new name for
the Cisco VSC 3000 and Cisco SC 2200. Some parts of this document may use these older names.
Note
The procedures in this chapter require a working knowledge of the system administration procedures for
the Sun Solaris (UNIX) operating system.
Note
Be sure to have the required information listed in Chapter 1, Preparing for Sun Solaris Operating
System and Cisco MGC Software Installation, before you begin the installation process.
Note
Note
Allow at least two hours down time for the installation of the Sun Solaris 8 operating
system.
Note
The text in the screens displayed throughout this document may differ slightly from the text displayed
on your console. The screen displays are for reference only and should be treated as examples.
Note
Most of the steps in the installation process ask you to press F2 to continue. However, F2 does not apply
to all console types. In this case, you should press Esc+2 instead.
Tip
During the installation process, monitor system output frequently for error messages and
correct any error conditions before continuing with the installation.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-3
Chapter 2
Note
In order to use Cisco Voice Services Provisioning Tool (Cisco VSPT) to provision MGC, you need to
install SUNWtftp package for Solaris 8 after you install the Solaris 8 operating system. You can
download that package from the Sun website.
Ethernet Interfaces
Platform Type
First
Second
Disk Drives
Third
Fourth
First
Second
Third
Fourth
Netra t 100/105
hme0
hme1 or
qfe01
n/a
n/a
c0t0d0
c0t0d1
n/a
n/a
Netra t
1120/1125
hme0
hme1
n/a
n/a
c0t0d0
c0t0d1
n/a
n/a
Netra t
1400/1405
hme0
n/a
c0t0d0
c0t0d1
n/a
n/a
eri0
c1t1d0
n/a
n/a
bge03
bge13
bge21
bge31
c1t0d0
c1t1d0
n/a
n/a
n/a
n/a
c1t0d0
c1t1d0
n/a
n/a
c1t0d0
c1t1d0
n/a
Netra 20
eri0
Netra 240
bge0
Netra 440
ce0
hme0 or ce0
3
bge1
ce1
bge2
n/a
bge3
n/a
c1t0d0
c1t1d0
c1t2d0
n/a
4
c1t3d04
1. These interfaces are supported only on platforms hosting the BAMS application. Support for the "bge" and ce interfaces requires Solaris Environment
Patches 2.0(11) or later, and BAMS 3.13 Patch 13 or later.
2. Support for these ce interfaces requires Solaris Environment Patches 2.0(8) or later, and MGC 9.4(1) with the latest patches.
3. Support for these bge and ce interfaces require Solaris Environment Patches 2.0(11) or later, and Cisco MGC 9.4(1) patch CSCOgs028 or later.
4. This device is not used currently.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-4
OL-1150-15
Chapter 2
Step 2
Place the system in single-user mode by shutting down the standby machine.
b.
When the machine prompts for password, type either ^ -d to proceed with normal startup, or the root
password for system maintenance.
Step 3
Load the CD-ROM labeled Solaris 8 Software CD (disk 1 of 2) into the CD-ROM drive.
Step 4
If the system is currently running, log in as root and bring the system to the ok prompt by entering the
following command:
# init 0
Note
If you are prompted to select a language before booting from the CD, go to the ok prompt by
sending a break on the console port. On the Sun Fire V210, Netra 20, 240, and 440 platforms,
the key sequence <cr>#. will get you to the system controller prompt.
From the system controller prompt, use the break -y command to break out of the operating
system and console -f command to return to the console display. You should see the ok prompt.
Step 5
From the following list, select the procedure that corresponds to the machine you are installing.
a.
Step 6
b.
c.
d.
e.
f.
g.
h.
Boot the system from the CD-ROM drive by entering the following command at the ok prompt:
ok boot cdrom
Step 7
Type the number 0 for the English language. Press Enter to continue.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-5
Chapter 2
Note
Step 8
If you are using the 10/01 installation CDs: If your system is located in the USA, type 53
(en_US.ISO8859-1) and press Enter to continue.
If your location is not in the USA, type the number 0 for English and press Enter to continue.
a.
If you are using the 2/02 installation CDs: If your system is located in the USA, type 48the
number that corresponds to USA (en_US.ISO8859-1)and press Enter to continue.
b.
If you are using the 2/04 installation CDs: If your system is located in the USA, type 49the
number that corresponds to USA (en_US.ISO8859-1)and press Enter to continue.
If your location is not in the USA, type the number 0 for English and press Enter to continue.
Note
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-6
OL-1150-15
Chapter 2
Step 9
Enter the number that corresponds to the terminal you are using and press Enter. For example, if you
are using an X terminal emulator, type 12 and press Enter.
A screen similar to the following is displayed:
- The Solaris Installation Program -------------------------------------------The Solaris installation program is divided into a series of short sections
where you'll be prompted to provide information for the installation. At
the end of each section, you'll be able to change the selections you've
made before continuing.
About navigation...
- The mouse cannot be used.
- If your keyboard does not have function keys, or they do not
respond, press ESC; the legend at the bottom of the screen
will change to show the ESC keys to use for navigation.
------------------------------------------------------------------------------F2_Continue
F6_Help
Step 10
Press F2 to continue.
A screen similar to the following is displayed:
- Identify This System -------------------------------------------------------On the next screens, you must identify this system as networked or
non-networked, and set the default time zone and date/time.
If this system is networked, the software will try to find the information
it needs to identify your system; you will be prompted to supply any
information it cannot find.
> To begin identifying this system, press F2.
------------------------------------------------------------------------------F2_Continue
F6_Help
Step 11
Press F2 to continue.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-7
Chapter 2
Networked
--------[X] Yes
[ ] No
------------------------------------------------------------------------------F2_Continue
F6_Help
Step 12
Use the arrow keys to navigate and press the space bar to make your selection. Verify that Yes is selected
and press F2 to continue.
A screen similar to the following is displayed:
- DHCP -----------------------------------------------------------------------On this screen you must specify whether or not this system should use DHCP
for network interface configuration. Choose Yes if DHCP is to be used, or
No if the interfaces are to be configured manually.
WARNING: Because this machine booted from the network, DHCP support will not
be enabled, if selected, until after the system reboots.
Use DHCP
-------[ ] Yes
[X] No
------------------------------------------------------------------------------F2_Continue
F6_Help
Step 13
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-8
OL-1150-15
Chapter 2
Note
Step 14
This screen may show a different interface, depending on the platform and PCI card that are
installed. For details, refer to Table 2-2 on page 2-4 (Device Names on Supported Cisco MGC
Software Platforms).
Host name:
------------------------------------------------------------------------------F2_Continue
F6_Help
Step 15
Type the host name of the target Netra machine, then press F2 to continue.
Note
For machine-specific information such as host name, refer to your notes in Table 1-2 on
page 1-4, Required Machine-specific Information, if you used the checklist to note down the
host name.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-9
Chapter 2
IP address:
------------------------------------------------------------------------------F2_Continue
Step 16
F6_Help
Enter the IP address of this machine in dotted decimal format and press F2 to continue.
Note
Refer to Required Information Checklist, Table 1-3 on page 1-4, if you used the checklist to
note down the IP address.
Step 17
Verify that Yes is selected (use the arrow keys to move the cursor to Yes and press the spacebar to select
it). Press F2 to continue.
A screen similar to the following is displayed:
- Netmask -----------------------------------------------------------------------On this screen you must specify the netmask of your subnet. A default
netmask is shown; do not accept the default unless you are sure it is
correct for your subnet. A netmask must contain four sets of numbers
separated by periods (for example 255.255.255.0).
Netmask:
---------------------------------------------------------------------------------F2_Continue
F6_Help
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-10
OL-1150-15
Chapter 2
Step 18
Enter the site-specific IP netmask for the subnet (see Site-specific Information, Table 1-2 on
page 1-3, if you noted down the information provided by your site administrator in this table). Press F2
to continue.
A screen similar to the following is displayed:
- IPv6 -----------------------------------------------------------------------On this screen you should specify whether or not IPv6, the next generation
Internet Protocol, will be enabled on this machine. Enabling IPv6 will have
no effect if this machine is not on a network that provides IPv6 service.
IPv4 service will not be affected if IPv6 is enabled.
> To make a selection, use the arrow keys to highlight the option and
press Return to mark it [X].
Enable IPv6
----------[ ] Yes
[X] No
------------------------------------------------------------------------------F2_Continue
F6_Help
Step 19
Yes
No
hme0
<host-name>
<IP address>
Yes
<IP netmask>
No
------------------------------------------------------------------------------F2_Continue
F4_Change
F6_Help
Step 20
Confirm the information displayed. Press F2 to accept the information and continue, or press F4 to go
back and make changes.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-11
Chapter 2
------------------------------------------------------------------------------F2_Continue
F6_Help
Step 21
------------------------------------------------------------------------------F2_Continue
F4_Change
F6_Help
Step 22
Name service
-----------[ ] NIS+
[ ] NIS
[ ] DNS
[X] None
------------------------------------------------------------------------------F2_Continue
F6_Help
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-12
OL-1150-15
Chapter 2
Step 23
Use the arrow keys to move the cursor to None and press the spacebar to select it. Press F2 to continue.
A screen similar to the following is displayed:
- Confirm Information --------------------------------------------------------> Confirm the following information. If it is correct, press F2;
to change any information, press F4.
Step 24
Step 25
Note
a.
The following two steps are examples of how to set the time zone, in this case, to United States
Eastern time.
Use the arrow keys to move the cursor to United States and press the spacebar to select it, then press
F2 to continue.
A screen similar to the following is displayed:
- Time Zone ------------------------------------------------------------------> To make a selection, use the arrow keys to highlight the option and
press Return to mark it [X].
Time zones
---------------[X] Eastern
[ ] Central
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-13
Chapter 2
[
[
[
[
[
[
[
[
[
]
]
]
]
]
]
]
]
]
Mountain
Pacific
East-Indiana
Arizona
Michigan
Samoa
Alaska
Aleutian
Hawaii
------------------------------------------------------------------------------F2_Continue
F5_Cancel
F6_Help
b.
Use the arrow keys to move the cursor to your time zone (in this example, Eastern is selected) and
press the space bar to select it. Press F2 to continue.
A screen similar to the following is displayed:
- Date and Time --------------------------------------------------------------> Accept the default date and time or enter
new values.
Date and time: 2001-01-04 10:59
Year
Month
Day
Hour
Minute
(4 digits)
(1-12)
(1-31)
(0-23)
(0-59)
:
:
:
:
:
2002
03
20
10
59
------------------------------------------------------------------------------F2_Continue
F6_Help
Step 26
Step 27
Confirm that the information displayed is correct. Press either F2 to accept the information and continue,
or F4 to go back and make changes.
A screen similar to the following may be displayed:
Please wait...
System identification is completed.
Starting Solaris installation program...
Executing JumpStart preinstall phase...
Searching for SolStart directory...
Checking rules.ok file...
Using begin script: install_begin
Using finish script: patch_finish
Executing SolStart preinstall phase...
Executing begin script "install_begin"...
Begin script install_begin execution completed.
System identification is now complete. Proceed to the next section, Installing the Solaris 8 Operating
System.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-14
OL-1150-15
Chapter 2
Note
These procedures cover the 18 GB, 36 GB, and 73 GB disk drives (see Step 11, below).
Upon acceptance of Step 27 in the previous section, Booting from a Local CD-ROM, a screen similar
to the following may be displayed if there is a previous file system on the disk:
- Solaris Interactive Installation -------------------------------------------This system is upgradable, so there are two ways to install the Solaris
software.
The Upgrade option updates the Solaris software to the new release, saving
as many modifications to the previous version of Solaris software as
possible. Back up the system before using the Upgrade option.
The Initial option overwrites the system disks with the new version of
Solaris software. This option allows you to preserve any existing file
systems. Back up any modifications made to the previous version of Solaris
software before starting the Initial option.
After you select an option and complete the tasks that follow, a summary of
your actions will be displayed.
------------------------------------------------------------------------------F2_Upgrade
F4_Initial
F5_Exit
F6_Help
Step 1
Press F4 for Initial Installation and continue. The following screen is displayed:
- Solaris Interactive Installation -------------------------------------------You'll be using the initial option for installing Solaris software on the
system. The initial option overwrites the system disks when the new Solaris
software is installed.
On the following screens, you can accept the defaults or you can customize
how Solaris software will be installed by:
- Selecting the type of Solaris software to install
- Selecting disks to hold software you've selected
- Specifying how file systems are laid out on the disks
After completing these tasks, a summary of your selections (called a
profile) will be displayed.
There are two ways to install the software - standard and flash
------------------------------------------------------------------------------F2_Standard
F3_Go Back
F4_Flash F5_Exit
F6_Help
Step 2
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-15
Chapter 2
>
>
>
>
>
>
>
>
>
>
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[/]
[ ]
[ ]
[ ]
Middle East
Central America
South America
Northern Europe
Southern Europe
Central Europe
North America
Australasia
Western Europe
Northern Africa
Step 3
Use the arrow keys to move the cursor to the geographic region of the target machine and press the
spacebar to make your selection. Press F2 to continue.
Note
The following two screens are not displayed when installing on newer platforms such as Sun Fire
V120, Sun Fire V210, Netra 20, Netra 120, Netra 240, or Netra 440. Continue to Step 4.
[X]
------------------------------------------------------------------------------F2_Continue
F3_Go Back
F5_Exit
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-16
OL-1150-15
Chapter 2
Step 4
If the preceding screen is displayed, verify the that Select To Include Solaris 64-bit Support is selected
and press F2 to continue.
A screen similar to the following is displayed:
- Select Software ------------------------------------------------------------Select the Solaris software to install on the system.
NOTE: After selecting a software group, you can add or remove software by
customizing it. However, this requires understanding of software
dependencies and how Solaris software is packaged
[ ]
[ ]
[ ]
[X]
[ ]
------------------------------------------------------------------------------F2_Continue
F3_Go Back
F4_Customize
F5_Exit
F6_Help
Step 5
Use the arrow keys to move the cursor to Developer System Support with 64 bit support for the 10/01
and 2/02 releases, or Entire Distribution with 64 bit for the 2/04 release, and press the space bar to
select. Then press F2 to continue.
A screen similar to the following is displayed:
- Select Disks ---------------------------------------------------------------On this screen you must select the disks for installing Solaris software.
Start by looking at the Suggested Minimum field; this value is the
approximate space needed to install the software you've selected. Keep
selecting disks until the Total Selected value exceeds the Suggested Minimum
value.
Disk Device (Size)
Available Space
=============================================
[X] c0t0d0
(17269 MB) boot disk
17269 MB
[ ] c0t1d0
(17269 MB)
17269 MB
Total Selected:
Suggested Minimum:
(F4 to edit)
17269 MB
845 MB
------------------------------------------------------------------------------F2_Continue
F3_Go Back
F4_Edit
F5_Exit
F6_Help
Note
For the device names for each platform type, refer to Table 2-2 on page 2-4 (Device Names on
Supported Cisco MGC Software Platforms).
If the machine has a larger disk drive than the 18 GB disks shown here, the Size and Available
Space fields will be different.
Netra 440 will display with four disks, but only two will be used.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-17
Chapter 2
Step 6
PGW Host: When installing Solaris for a PGW Host, make sure that only the first disk device is
selected. For the device names for each platform type, refer to Table 2-2 on page 2-4 (Device Names
on Supported Cisco MGC Software Platforms).
Press F2 to continue.
Note
Caution
For the PGW Host, the second disk device may be configured as a mirror of the first or as
storage space for logs, measurements, alarm, and CDR files. This is done in the
Configuring a Second Disk Drive section on page 2-32.
If your PGW Host has the Cisco MGC software and the Cisco Voice Services Provisioning Tool (VSPT)
installed, you must perform the procedures that follow to configure the Solaris environment for the PGW.
The Cisco MGC software requires a particular configuration of the Solaris environment to function
properly.
b.
HSI: When installing Solaris for HSI with two disks, verify that both the first and second disk
devices are selected.
When installing Solaris for HSI on a platform with a single disk, verify that only the first disk device
is selected.
For the device names for each platform type, refer to Table 2-2 on page 2-4 (Device Names on
Supported Cisco MGC Software Platforms).
Press F2 to continue.
Note
c.
For the HSI, the second disk device may be configured as a mirror of the first. This is done
in the Configuring a Second Disk Drive section on page 2-32.
BAMS with Disk Array: When installing Solaris for a BAMS on a Netra 1400/1405 with an
st A1000 Disk Array, verify that only the first disk device is selected. For the device names for each
platform type, refer to Table 2-2 on page 2-4 (Device Names on Supported Cisco MGC Software
Platforms).
Press F2 to continue.
d.
BAMS without Disk Array only: When installing Solaris for a BAMS without a Disk Array, verify
that both the first and second disk devices are selected. For the device names for each platform type,
refer to Table 2-2 on page 2-4 (Device Names on Supported Cisco MGC Software Platforms).
Press F2 to continue.
Step 7
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-18
OL-1150-15
Chapter 2
------------------------------------------------------------------------------F2_Auto Layout
F3_Go Back
F4_Manual Layout
F5_Exit
F6_Help
Step 8
------------------------------------------------------------------------------F2_Continue
F5_Cancel
F6_Help
Step 9
Press F2 to continue.
A screen similar to the following is displayed:
- File System and Disk Layout ------------------------------------------------The summary below is your current file system and disk layout, based on the
information you've supplied.
NOTE: If you choose to customize, you should understand file systems, their
intended purpose on the disk, and how changing them may affect the operation
of the system.
File system/Mount point
Disk/Slice
Size
=============================================================
/
c0t0d0s0
1270 MB
swap
c0t0d0s1
296 MB
overlap
c0t0d0s2
17269 MB
/export/home
c0t0d0s7
15702 MB
------------------------------------------------------------------------------F2_Continue
F3_Go Back
F4_Customize
F5_Exit
F6_Help
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-19
Chapter 2
Step 10
----------------------------------------------------
Disk
(Size)
Configured File Systems
==================================================================
[
[
] c0t0d0
] c0t1d0
(34730 MB)
(34730 MB)
/, swap, /export/home
/export/home
------------------------------------------------------------------------------F2_OK
F4_Customize
F6_Help
Step 11
Select each disk using the up and down arrows and press F4 to customize.
Note
The following screen may not be displayed for Solaris 2/04. The disk was already selected in
Step 6.
Note
Step 12
For the device names for each platform type, refer to Table 2-2 on page 2-4 (Device Names on
Supported Cisco MGC Software Platforms). If the machine has a larger disk drive than the 18
GB shown here, Size and Available Space fields will be different.
Use the Tab key to navigate from field to field on this display. Enter the partition name and size to match
the corresponding drive in Table 2-3 through Table 2-6.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-20
OL-1150-15
Chapter 2
Caution
Make sure that you select the correct tables based on the disk drive being configured (Disk 0
or Disk 1), as well as the correct disk size. Select the column in the table that matches the
software that will be installed on the platform later.
For BAMS, select the correct column based on whether the platform will have an external disk
array attached.
Caution
In the partition tables that follow, slice 2 is the overlap slice. It is configured by default to be
the whole disk. This slice entry is only used for test and maintenance purposesit is not
mounted by the operating system. This slice entry should not be changed.
You must remove slice 7 before configuring the rest of the drive.
Due to rounding, the size of the slice shown after entry may be slightly larger than what was
entered (for example, an entry of 1024 may be rounded up to 1025 or 1026).
Disks 2 and 3 are not currently used.
Caution
For HSI: If you are upgrading from HSI 2.2 to HSI 4.1, make sure that your disks are
correctly partitioned to support disk mirroringpartitioning requires the new disk layout.
If your disks are not correctly partitioned, you must re-partition your disks.
Note
There may be an unnamed partition in some of the following tables that is created without a
mount point (slice 7) for the PGW Host and HSI. The DiskSuite disk mirroring software uses
this partition. If DiskSuite is not used, then the space is unused.
Note
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-21
Chapter 2
Table 2-3
PGW Host
Slice
No.
Slice
Name
Slice Size
(MB)
Slice Name
Slice Size
(MB)
HSI
Slice Name
Slice Size
(MB)
0.
512
1000
1024
512
swap
4096
swap
2040
swap
4096
swap
4096
overlap
17269
overlap
17269
overlap
17269
overlap
17269
/opt
6144
/opt
10590
/opt
1729
/opt
11110
/var
1024
/var
1024
/usr
1024
/usr
1024
/usr
1024
/usr
1024
/opt/CiscoBAMS/CDR/archive
11000
/export
4081
15
15
Table 2-4
PGW Host
(See Configuring a
Second Disk Drive,
page 2-32)
Slice
No.
Slice
Name
0.
overlap
17269
Slice
Size (MB)
Slice Name
/opt/CiscoBAMS/data
overlap
15
Slice Size
(MB)
Slice Size
(MB)
HSI
(See Configuring a Second
Disk Drive, page 2-32)
Slice Name
Slice Size
(MB)
17269
17269
overlap
17269
overlap
17269
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-22
OL-1150-15
Chapter 2
Table 2-5
PGW Host
Slice
Name
Slice
No.
Slice
Size
(MB)
Slice Name
Slice
Size
(MB)
Slice Name
HSI
Slice
Size
(MB)
Slice Name
Slice Size
(MB)
0.
1024
2048
2048
1024
swap
4096
swap
4096
swap
4096
swap
4096
overlap
34730
overlap
34730
overlap
34730
overlap
34730
/opt
25600
/opt
27545
/opt
3458
/opt
26537
/var
1024
/var
1024
/usr
2048
/usr
2048
/usr
2048
/usr
1024
/opt/CiscoBAMS/CDR/archive
23078
/export
920
15
Table 2-6
PGW
(See Configuring a
Second Disk Drive,
page 2-32)
Slice
No.
Slice
Name
overlap
Slice Size
(MB)
0.
15
Slice Name
/opt/CiscoBAMS/data
34730 overlap
Slice Size
(MB)
Slice Name
Slice Size
(MB)
HSI
(See Configuring a
Second Disk Drive,
page 2-32)
Slice Name
Slice Size
(MB)
34730
34730
overlap
34730
overlap
34730
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-23
Chapter 2
Table 2-7
PGW Host
Slice Slice Name
No.
Slice Size
(MB)
Slice Name
HSI
Slice Size
(MB)
Slice
Name
Slice Size
(MB)
0.
4099 /
4099 /
4099
1028
swap
4099 swap
4099 swap
4099
swap
4099
overlap
69994 overlap
69994 overlap
69994
overlap
69994
/opt
59341
/opt
53553 /opt
8193 /opt
57697
/var
1028
/var
4099 /usr
4099 /usr
4099
/usr
2052
/usr
4099 /opt/CiscoBAMS/CDR/archive
/export
2399
49503
44
44
Table 2-8
PGW Host
(See Configuring a Second
Disk Drive, page 2-32)
Slice
No.
Slice Name
Slice Size
(MB)
0.
Slice Name
/opt/CiscoBAMS/data
Slice Size
(MB)
Slice Name
Slice Size
(MB)
HSI
(See Configuring a
Second Disk Drive,
page 2-32)
Slice
Name
Slice Size
(MB)
69994 overlap
69994
69994
1
2
overlap
69994 overlap
69994 overlap
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-24
OL-1150-15
Chapter 2
Table 2-9
PGW Host
(Not Supported)
Slice
No.
Slice Name
Slice Name
Slice Size
(MB)
Slice Name
HSI
(Not Supported)
Slice Size
(MB)
Slice
Name
Slice Size
(MB)
69994 overlap
69994
0.
1
2
overlap
69994 overlap
69994 overlap
Table 2-10
PGW Host
(Not Supported)
Slice
No.
Slice Name
Slice Size
(MB)
Slice Name
Slice Size
(MB)
Slice Name
HSI
(Not Supported)
Slice Size
(MB)
Slice
Name
Slice Size
(MB)
69994 overlap
69994
0.
1
2
overlap
69994 overlap
69994 overlap
PGW Host
Slice Slice Name
No.
Table 2-11
Table 2-12
Slice Size
(MB)
Slice Name
HSI
Slice Size
(MB)
Slice
Name
Slice Size
(MB)
0.
4104 /
4099 /
4099
1028
swap
4104 swap
4099 swap
4099
swap
4099
overlap
139989 overlap
139989 overlap
139989
overlap
69994
/opt
59341
/var
1028
3
4
0
/opt
123523 /opt
0
8193 /opt
115395
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-25
Chapter 2
/var
4104 /usr
/usr
4104 /opt/CiscoBAMS/CDR/archive
4099 /usr
4099
99007 0
/usr
2052
/export
2399
49
44
PGW Host
(Not Supported)
Slice
No.
Slice Name
0.
Slice Name
/opt/CiscoBAMS/
data
Slice Size
(MB)
Slice Size
(MB)
HSI
(Not Supported)
Slice
Name
Slice Size
(MB)
139989 overlap
139989
139989
1
2
overlap
139989 overlap
139989 overlap
0
Step 13
When the configuration is complete, press F2 to accept and continue. If you are configuring two disks
and both disks have been customized correctly, press F2 a second time.
The following screen reflects the 18 GB disk drive configuration for the Cisco MGC software
application. It will differ for the BAMS and HSI installation and for all installations on 36 GB or 73 GB
disks.
- File System and Disk Layout ------------------------------------------------The summary below is your current file system and disk layout, based on the
information you've supplied.
NOTE: If you choose to customize, you should understand file systems, their
intended purpose on the disk, and how changing them may affect the operation
of the system.
File system/Mount point
Disk/Slice
Size
=============================================================
/
c0t0d0s0
513 MB
swap
c0t0d0s1
4097 MB
overlap
c0t0d0s2
17269 MB
/opt
c0t0d0s4
10590 MB
/var
c0t0d0s5
1026 MB
/usr
c0t0d0s6
1026 MB
c0t0d0s7
15 MB
------------------------------------------------------------------------------F2_Continue
F3_Go Back
F4_Customize
F5_Exit
F6_Help
Step 14
If the display does not coincide with the entered data (see the Note in Step 6), press F3 to go back and
make changes. If the information displayed is acceptable, press F2 to continue.
A screen similar to the following is displayed:
- Mount Remote File Systems? --------------------------------------------------
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-26
OL-1150-15
Chapter 2
Do you want to mount software from a remote file server? This may be
necessary if you had to remove software because of disk space problems.
------------------------------------------------------------------------------F2_Continue
F3_Go Back
F4_Remote Mounts
F5_Exit
F6_Help
Step 15
Press F2 to continue.
A screen similar to the following is displayed:
- Profile ---------------------------------------------------------------------
The information shown below is your profile for installing Solaris software.
It reflects the choices you've made on previous screens.
============================================================================
Installation Option: Initial
|
Boot Device: c0t0d0
|
Client Services: None
|
|
Locales: U.S.A. (en_US.ISO8859-1)
|
|
Software: Solaris 8, Developer System Support 64-bit
|
|
File System and Disk Layout:
v
------------------------------------------------------------------------------F2_Continue
F4_Change
F5_Exit
F6_Help
Step 16
If the display does not coincide with the data that is entered, press F4 to make changes. Otherwise, press
F2 to accept the information displayed and continue.
A screen similar to the following is displayed:
- Warning --------------------------------------------------------------------The following disk configuration condition(s) have been
detected. Errors must be fixed to ensure a successful
installation. Warnings can be ignored without causing the
installation to fail.
WARNING: Unused disk space (c0t0d0)
------------------------------------------------------------------------------F2_OK
F5_Cancel
Step 17
A small amount of disk space (required for DiskSuite installation) is left unused, causing the displayed
warning. This will not effect the installation. Press F2 to continue.
A screen similar to the following is displayed:
- Reboot After Installation? -------------------------------------------------After Solaris software is installed, the system must be rebooted. You can
choose to have the system automatically reboot, or you can choose to
manually reboot the system if you want to run scripts or do other
customizations before the reboot. You can manually reboot a system by using
the reboot(1M) command.
[X] Auto Reboot
[ ] Manual Reboot
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-27
Chapter 2
------------------------------------------------------------------------------F2_Begin Installation
F5_Cancel
Step 18
Press F2 to automatically reboot after the Solaris 8 operating system is installed and to continue. This
begins the actual operating system installation.
A screen similar to the following is displayed:
Preparing system for Solaris install.
As the installation program sets up the disk drive for the OS installation, lines similar to the following
are appended to the display:
Configuring disk (c0t0d0)
- Creating Solaris disk label (VTOC)
Creating and checking UFS file systems
- Creating / (c0t0d0s0)
- Creating /opt (c0t0d0s4)
- Creating /var (c0t0d0s5)
- Creating /usr (c0t0d0s6)
Beginning Software Installation
Solaris Initial Install
MBytes Installed:
MBytes Remaining:
xxx.xx
xxx.xx
|
0
|
20
|
40
|
60
|
80
|
100
When the installation of the Solaris 8 operating system on Disk 1 of 2 is complete, information similar
to the following scrolls through the display and the machine reboots:
Solaris 8 software installation succeeded
Customizing system files
- Mount points table (/etc/vfstab)
- Unselected disk mount points (/var/sadm/system/data/vfstab.unselected)
- Network host addresses (/etc/hosts)
Customizing system devices
- Physical devices (/devices)
- Logical devices (/dev)
Installing boot information
- Installing boot blocks (c0t0d0s0)
Installation log location
- /a/var/sadm/system/logs/install_log (before reboot)
- /var/sadm/system/logs/install_log (after reboot)
Installation complete
Executing SolStart postinstall phase...
Executing finish script "patch_finish"...
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-28
OL-1150-15
Chapter 2
Step 19
Refer to Table 1-2 for the root password for this system and type it. Press Enter to continue. The
following line is appended to the display and you will be prompted to confirm the root password.
Re-enter your root password.
Press Return to continue.
Step 20
Re-type the root password for this system, then press Enter.
A screen similar to the following is displayed:
System identification is completed.
Note
The next two screens are not displayed when installing on newer systems such as Sun Fire V120,
Sun Fire V210, Netra 120, Netra 20, Netra 240, or Netra 440 platforms.
================================================================
This system is configured to conserve energy.
================================================================
After 30 minutes of idle time on this system, your system state will
automatically be saved to disk, and the system will power-off. Later, when you
want to use the system again, and you turn the power back on, your system will
be restored to its previous state, including all the programs that you were
running. Do you want this automatic power-saving shutdown? (If this system is
used as a server, answer n) [y,n,?]
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-29
Chapter 2
Step 21
Type n and press Enter to disable the power saving feature and continue. The following lines are
appended to the display:
Autoshutdown has been disabled.
Do you want the system to ask about this again, when you next reboot? (This
gives you the chance to try it before deciding whether to keep it.) [y,n,?]
Step 22
Type n and press Enter to permanently disable the power saving feature and continue. The installation
continues and text similar to the following are displayed:
Starting Web Start Launcher in Command Line Mode.
Please specify the media from which you will be installing Solaris 8 (SPARC)
Software 2.
Alternatively, choose the selection for "Skip" to skip this CD and go on to the
next one.
Media:
1. CD
2. Network File System
3. Skip
Media [1]: 1
Step 23
Type 1 Press Enter to continue. The following lines are appended to the display:
Please insert the CD for Solaris 8 (SPARC) Software 2.
Once the CD has been inserted, please press Enter.
Enter S to skip this CD and go on to the next one.
To select a different media, enter B to go Back.
[]
Note
Step 24
For the Sun Fire V210 and Netra 240 and 440: The screen output is CD/DVD.
Remove the Solaris 8 Software CD, Disk 1 of 2, load Solaris 8 Software CD, Disk 2 of 2, and press Enter to
continue.
Lines similar to the following are appended to the display:
Reading Solaris 8 (SPARC) Software 2.... \
1.
Product
Solaris 8 Software 2
2.
Done
Result
Installed
More Info
Available
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-30
OL-1150-15
Chapter 2
Step 25
Step 26
Step 27
Step 28
Step 29
Define the default router address and make it permanent by performing the following:
a.
b.
Put the default gateway IP address on the first and only line of the file by entering the following
command:
# echo default_router_IP_address > /etc/defaultrouter
This completes the installation of the Solaris 8 operating system. Proceed to the following section to
verify Network Time Protocol (NTP) Packages.
Step 2
Echo the NTP server IP Address into the file /etc/inet/ntp.conf by entering the following command
(the NTP server address is provided by your system administrator):
# echo "server NTP_server_IP_address" > /etc/inet/ntp.conf
Step 3
Cisco PGW 2200 requires the NTP daemon to always use slewing mechanism to synchronize the local
clock with the NTP server reference time. To enable slewing, enter the following commands to add the
lines in the /etc/inet/ntp.conf file (Note the use of the double arrows ">>"):
# echo "slewalways yes" >> /etc/inet/ntp.conf
# echo "disable pll" >> /etc/inet/ntp.conf
Step 4
Reboot the machine with the following command to activate the default route:
# reboot -- -r
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-31
Chapter 2
Step 5
Log in as root.
Step 6
Verify that the deamon xntpd is running by entering the following command:
ps -ef | grep ntp
This completes the procedure for verifying that the correct Network Time Protocol (NTP) packages are
installed.
To continue the Solaris 8 operating system installation, go to the following sections in this chapter:
For PGW Host: Proceed to the Configuring a Second Disk Drive section on page 2-32 for
procedures on configuring a second disk drive, then proceed to the Configuring Additional Ethernet
Interfaces section on page 2-45 if you are configuring additional Ethernet interfaces.
For BAMS: Proceed to the Installing the BAMS Disk Array on a Netra t 140x Host section on
page 2-54, then proceed to the Configuring Additional Ethernet Interfaces section on page 2-45 if
you are configuring additional Ethernet interfaces.
For HSI: Proceed to the Configuring a Second Disk Drive section on page 2-32 for procedures
on configuring a second disk drive, then proceed to the Configuring Additional Ethernet Interfaces
section on page 2-45 if you are configuring additional Ethernet interfaces.
This section applies to the PGW Host running either the Cisco MGC or HSI software.
The following options are available at this stage of the installation process:
1.
Use the second disk drive as a mirror of the first to increase the availability of the system. Refer to
the Installing the Solstice DiskSuite (CSCOh016) section on page 2-32 to install DiskSuite.
2.
Only for systems running the Cisco MGC software: Use the second disk drive for log and spool
systems to increase the capacity for log, alarm, measurement and CDR files. This increases the
performance of the machine. Refer to the Installing the Log and Spool File Systems (CSCOh005)
section on page 2-37.
If CSCOh005 is not installed, you will continue to have log and spool file system on the first disk
drive.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-32
OL-1150-15
Chapter 2
Caution
The order in which packages are installed on the system is important. In particular, DiskSuite
(located in the CSCOh016 package) must be installed before installing the Cisco PGW application
(CiscoMGC software) and the Cisco Security package (CSCOh013).
If your system already has the CSCOh015 software package installed and you install CSCOh016, you
must run the CSCOh015 installation script again to ensure compatibility between the two software
packages (see Step 10, below).
When removing DiskSuite, you must remove CSCOh013 and the Cisco PGW application before
removing DiskSuite. If the CSCOh013 package or the Cisco PGW application are already installed, the
DiskSuite scripts will fail to run.
Note
You must log in as root to run the following DiskSuite installation script.
Note
If you have installed the Solaris 8 operating system on the platform with only one hard disk, shut down
the server and insert a second disk. Turn on the server and log in as root. Run the UNIX command,
/usr/sbin/shutdown -g0 -y -i0, to enter the OK mode. Then run the command, boot -rv, in OK mode to
detect the newly inserted hard disk.
Step 1
Load the Cisco Solaris 8 Patches CD into the CD-ROM drive. Enter the following command to install
the DiskSuite installation scripts:
pkgadd -d /cdrom/cdrom0/CSCOh016.pkg
This command copies the DiskSuite installation scripts into the directory /opt/sun_install/DiskSuite.
Step 2
Enter the following command to open the door of the CD-ROM drive:
eject
Remove the Cisco Solaris 8 Patches CD and re-install the Solaris CD (#2 of 2) in the CD-ROM drive.
Step 3
Step 4
/opt/sun_install/DiskSuite
This script installs the DiskSuite packages from the Sun Solaris CD (disk #2). The machine reboots after
installing the packages.
Step 5
Log in as root and enter the following command to open the door of the CD-ROM drive:
eject
Step 7
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-33
Chapter 2
This script formats the second disk drive with a partition table that is identical to the first drive on the
system (where Solaris was installed). It creates the required DiskSuite disk partitions and databases. The
machine reboots after creating the disk partitions and databases.
Step 8
Log in as root and go to the /opt/sun_install/DiskSuite directory. Enter the following command:
cd /opt/sun_install/DiskSuite
Step 9
This script attaches the meta-disks and starts the disk mirroring.
Caution
Step 10
Skip this step if the CSCOh015 software package is not installed in your system. However, if the
CSCh015 software package is already installed, ensure that both CSCOh015 and CSCOh016 are
compatible by entering the following commands:
# cd /opt/sun_install
# ./installPatches8
Rebooting from the mirrored (secondary) disk is normally done only after a catastrophic failure of the
primary disk.
Perform the following procedure to add an alias in the boot ROM so you can boot off of the secondary
disk, if necessary.
Step 1
Get the information from the system on the second disk that you will boot from. Type the following
command and press Enter:
# prtconf -vp | grep pci | grep disk1
Note
a.
If the prtconf command returns the above information, you can use it to boot the second disk
without any additional changes. Proceed to Step 3.
b.
If you do not wish to use the above default information, create an alias name other than disk1 for
the second boot disk in the NVRAM by using the information from the prtconf command (above).
For example, to create an alias of "backup_root", enter the following command:.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-34
OL-1150-15
Chapter 2
Step 2
Check the alias you created by typing the following commands and pressing Enter:
eeprom |grep nvramrc
Note
In the steps that follow, wherever you see "disk1" would be replaced with the alias you configured above.
Step 3
Before shutting down the system, check the progress of the mirroring to make sure that replication
is complete. Type the following the command to check the progress of the mirroring. An Okay response
means that disk mirroring is complete.
/usr/sbin/metastat
Warning
Step 4
DO NOT REBOOT until the replication is complete and the mirrors are in the Okay state.
When the replication is complete, bring the machine down to the boot prompt. Type the following
command and press Enter:
# /usr/sbin/shutdown -g0 -y -i0
Verify that the following text is displayed in the boot output (see the output in Step 4, above). This
ensures that the machine was working from the second drive:
Executing last command: boot disk1
Boot device: /pci@1f,0/pci@1/scsi@8/disk@1,0 File and args:
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-35
Chapter 2
Note
If you have installed the Solaris DiskSuite package (CSCOh016) on your system, the messages
below are displayed during system boot-up. They are normal Solaris DiskSuite start-up
messages and do not indicate any problem with your system.
WARNING force load of misc /md-trans failed
WARNING force load of misc /md-raid failed
WARNING force load of misc /md-hotspares failed
WARNING force load of misc /md-sp failed
This completes the procedures for rebooting from the mirrored (secondary) disk.
This section applies to the PGW Host running either the Cisco MGC or HSI software. The
following procedure only works from platforms that have been mirrored using the procedure provided
in the Installing the Solstice DiskSuite (CSCOh016) section on page 2-32.
This procedure un-mirrors the disk partitions and removes the DiskSuite application from the platform.
Use this procedure if a system has DiskSuite installed and you no longer wish to use CSCOh005 to
configure the second disk for the log and spool directories.
If the platform is configured with customer-specific information, be sure to back up this information
before the partitions are un-mirrored and DiskSuite is removed. Consult the appropriate document,
depending on the software installed.
Step 1
Log in as root. Use the metastat command to verify that the state of all the mirrors is Okay.
Step 2
Type the following commands to run the script and press Enter:
cd /opt/sun_install/DiskSuite
sh rm_disksuite_1.sh
The sh rm_disksuite_1.sh command detaches the mirrored disks and restores the original disk partition
file in /etc/vfstab. The machine reboots after detaching the mirrored disks and restoring the original disk
partition file.
Step 3
Log in as root and change directory to /opt/sun_install/DiskSuite. Enter the following command:
cd /opt/sun_install/DiskSuite
Step 4
This script clears the disk mirrors and removes the DiskSuite software packages from the system.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-36
OL-1150-15
Chapter 2
This section applies to the PGW Host running the Cisco MGC software.
Note
If the DiskSuite software is installed and configured, you must first follow the procedure in the
Removing the Solstice DiskSuite section on page 2-36 to remove the DiskSuite software before
configuring the second disk to be used for the Log and Spool File Systems.
To determine whether DiskSuite is installed and configured, run the /usr/sbin/metastat command. If the
command is found and it displays the status of mirrors, it indicates that DiskSuite is installed and
configured.
Note
For the device names for each platform type, refer to Table 2-2 on page 2-4 (Device Names on Supported
Cisco MGC Software Platforms).
The following procedure configures the second disk of a PGW Host for use by the Cisco MGC software
as storage for log, alarm, measurement, and CDR files. The second disk is defined into two partitions,
as follows:
The first partition is the log partition and uses 40% of the disk.
The second partition is the spool partition that uses 60% of the disk.
Table 2-13 shows a sample partition table for the second disk of a Netra t 1400 with 36 GB disk drives.
Table 2-13
PGW Host
Slice No.
Note
Slice Name
0.
0.00
0.00
overlap
33.92
/opt/CiscoMGC/var/log
13.57
/opt/CiscoMGC/var/spool
20.35
0.00
0.00
0.00
If you have installed the Solaris 8 operating system on the platform with only one hard disk, shut down
the server and insert a second disk. Turn on the server and log in as root. Run the UNIX command,
/usr/sbin/shutdown -g0 -y -i0, to enter the OK mode. Then run the command, boot -rv, in OK mode to
detect the newly inserted hard disk.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-37
Chapter 2
Step 1
Load the Cisco PGW Solaris 8 Patch CD into the CD-ROM drive. From the /var/tmp directory of the
target Netra machine, install the Log And Spool Software by entering the following command:
# cd /var/tmp
# pkgadd -d /cdrom/cdrom0/CSCOh005.pkg
Step 2
Step 3
Step 4
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-38
OL-1150-15
Chapter 2
Note
You must first shut down the Cisco MGC before running the install_log_spool script.
# cd /opt/sun_install/Log_Spool
# ./install_log_spool
FORMAT MENU:
disk
type
partition
current
format
repair
label
analyze
defect
backup
verify
save
volname
!<cmd>
quit
format> disk
select a disk
select (define) a disk type
select (define) a partition table
describe the current disk
format and analyze the disk
repair a defective sector
write label to the disk
surface analysis
defect list management
search for backup labels
read and display labels
save new disk/partition definitions
set 8-character volume name
execute <cmd>, then return
c0t1d0
SUN36G
24620
Step 5
If the PGW displays the following error message, you need to unmount the /opt/CiscoMGC/var/log and
/opt/CiscoMGC/var/spool directories.
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
If DiskSuite or StorEdge VM is running, it must be disabled
The second disk must not be mounted to run this script
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-39
Chapter 2
Note
If the PGW does not display this error message, continue to the next step.
Enter the following commands to unmount the directories, and run the install_log_spool script again.
# umount /opt/CiscoMGC/var/log
# umount /opt/CiscoMGC/var/spool
Step 6
Press Enter to accept the default mount point for the log directory or change it if you plan on installing
the Cisco MGC software in a different location.
A screen similar to the following is displayed:
Log directory mount point is /opt/CiscoMGC/var/log
Enter absolute path of the desired mount point for the
spool directory or press enter to accept
the default [/opt/CiscoMGC/var/spool]:
Step 7
Press Enter to accept the default mount point for the spool directory or change it if you plan on installing
the Cisco MGC software in a different location.
A screen similar to the following is displayed:
Spool directory mount point is /opt/CiscoMGC/var/spool
Number of cylinders for log partition: 9848
Start: 0
Start: 9847
Number of cylinders for spool partition: 14772
Start: 9848
Start: 24619
Build partition table for c0t1d0 ...
Searching for disks...done
selecting c0t1d0
[disk formatted]
FORMAT MENU:
disk
type
partition
current
format
repair
label
analyze
defect
backup
verify
save
inquiry
volname
!<cmd>
quit
format> p
select a disk
select (define) a disk type
select (define) a partition table
describe the current disk
format and analyze the disk
repair a defective sector
write label to the disk
surface analysis
defect list management
search for backup labels
read and display labels
save new disk/partition definitions
show vendor, product and revision
set 8-character volume name
execute <cmd>, then return
PARTITION MENU:
0
- change `0' partition
1
- change `1' partition
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-40
OL-1150-15
Chapter 2
2
3
4
5
6
7
select
modify
name
print
label
!<cmd>
quit
partition> 0
Part
Tag
0
root
Flag
wm
Cylinders
0 725
Size
1.00GB
Blocks
(726/0/0)
2097414
Blocks
(19527/0/0) 56413503
31779
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-41
Chapter 2
Blocks
(0/0/0)
Flag
wm
wm
wm
wm
wm
wm
wm
wm
Cylinders
0
0
0 - 24619
0 - 9847
9848 - 24619
0
0
0
Size
0
0
33.92GB
13.57GB
20.35GB
0
0
0
Blocks
(0/0/0)
0
(0/0/0)
0
(24620/0/0) 71127180
(9848/0/0) 28450872
(14772/0/0) 42676308
(0/0/0)
0
(0/0/0)
0
(0/0/0)
0
partition> l
partition> q
FORMAT MENU:
disk
type
partition
current
format
repair
label
analyze
defect
backup
verify
save
inquiry
volname
!<cmd>
select a disk
select (define) a disk type
select (define) a partition table
describe the current disk
format and analyze the disk
repair a defective sector
write label to the disk
surface analysis
defect list management
search for backup labels
read and display labels
save new disk/partition definitions
show vendor, product and revision
set 8-character volume name
execute <cmd>, then return
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-42
OL-1150-15
Chapter 2
quit
format> q
unknown disk type, assuming the speed is 10000 rpm
Build log filesystem at /dev/rdsk/c0t1d0s3 ...
mkfs -F ufs /dev/rdsk/c0t1d0s3 28450872 107 27 8192 1024 251 1 166 8192 t 0 -1 8 107
Cylinder groups must have a multiple of 16 cylinders with the given parameters
Rounded cgsize up to 256
/dev/rdsk/c0t1d0s3:
28450872 sectors in 9848 cylinders of 27 tracks, 107 sectors
13892.0MB in 308 cyl groups (32 c/g, 45.14MB/g, 5632 i/g)
super-block backups (for fsck -F ufs -o b=#) at:
32, 92592, 185152, 277712, 370272, 462832, 555392, 647952, 740512, 833072,
.
.
.
Build spool filesystem at /dev/rdsk/c0t1d0s4 ...
mkfs -F ufs /dev/rdsk/c0t1d0s4 42676308 107 27 8192 1024 251 1 166 8192 t 0 -1 8 107
Cylinder groups must have a multiple of 16 cylinders with the given parameters
Rounded cgsize up to 256
/dev/rdsk/c0t1d0s4:
42676308 sectors in 14772 cylinders of 27 tracks, 107 sectors
20838.0MB in 462 cyl groups (32 c/g, 45.14MB/g, 5632 i/g)
super-block backups (for fsck -F ufs -o b=#) at:
32, 92592, 185152, 277712, 370272, 462832, 555392, 647952, 740512, 833072,
.
.
.
Remove any existing entry in /etc/vfstab for c0t1d0s3 or c0t1d0s4
Adding entries to /etc/vfstab
Mounting /opt/CiscoMGC/var/log
Mounting /opt/CiscoMGC/var/spool
Success!!!
Note
After the Log and Spool File system is successfully installed, you must install the Cisco Security
Patch (CSCOh013) if it was removed before DiskSuite was removed. For installation
procedures, see Installing the Cisco Security Package (CSCOh013) section on page 3-16.
This completes the installation of the Log and Spool File system.
Note
Step 1
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-43
Chapter 2
cd /opt/sun_install/Log_Spool/
./uninstall_log_spool
Step 2
Type y and press Enter to remove CSCOh005. Text similar to the following is displayed:
Unmount /opt/CiscoMGC/var/log
Unmount /opt/CiscoMGC/var/spool
Update /etc/vfstab
Remove old files...
The Log/Spool software has been removed from the system
Now you can remove the package with the command:
pkgrm CSCOh005
Done!
Step 3
Type the following command and press Enter to continue the removal of CSCOh005.
pkgrm CSCOh005
Step 4
Reboot your machine with the -r option. Type the following command and press Enter:
# reboot -- r
Note
If you have installed the Solaris DiskSuite package (CSCOh016) on your system, the messages
below are displayed during system boot-up. They are normal Solaris DiskSuite start-up
messages and do not indicate any problem with your system.
WARNING force load of misc /md-trans failed
WARNING force load of misc /md-raid failed
WARNING force load of misc /md-hotspares failed
WARNING force load of misc /md-sp failed
This completes the removal of the Log and Spool File system from the second disk.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-44
OL-1150-15
Chapter 2
Note
For Ethernet interface information for each platform type, refer to Table 2-2 on page 2-4 (Device Names
on Supported Cisco MGC Software Platforms).
Add the IP address and hostname of the additional Ethernet interfaces to the /etc/hosts file by typing the
following command for each Ethernet port:
# echo IP_address hostname.deviceX >> /etc/hosts
Where:
deviceXA combination of the Ethernet device type and the interface instance, such as hme1.
For example, to add an IP address, 172.24.237.52, for an Ethernet port, hme1, on a host called Madison
to the /etc/hosts file, you would enter the following command:
# echo 172.24.237.52 madison.hme1 >> /etc/hosts
Step 2
Create a new file to store the IP address or hostname for each additional Ethernet port by entering the
command listed below. Refer to Table 1-2 on page 1-3 (Site-specific Information) if you made notes
while preparing for the installation.
# echo IP_address > /etc/hostname.deviceX
Where:
For example, to enter an IP address of 172.24.237.52 for a second Ethernet interface of hme1, you would
enter the following command:
# echo 172.24.237.52 > /etc/hostname.hme1
Step 3
Add a line to the /etc/netmasks file for each unique subnet of the interfaces being added by entering the
command listed below. Multiple subnets of the same network address should have individual lines in the
/etc/netmasks file.
# echo subnet_address subnet_mask >> /etc/netmasks
Where:
For example, to enter a subnet address of 172.24.237.0 with a subnet mask of 255.255.255.0, you would
enter the following command:
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-45
Chapter 2
Step 4
The machine must now be rebooted with a -r option to complete the configuration. Enter the following
command:
# reboot -- -r
Note
If you have installed the Solaris DiskSuite package (CSCOh016) on your system, the messages
below are displayed during system boot-up. They are normal Solaris DiskSuite start-up
messages and do not indicate any problem with your system.
WARNING force load of misc /md-trans failed
WARNING force load of misc /md-raid failed
WARNING force load of misc /md-hotspares failed
WARNING force load of misc /md-sp failed
Step 5
When the machine finishes rebooting, log in as root and type the command ifconfig -a. Verify that the
new Ethernet interfaces appear in the output.
# ifconfig -a
A screen similar to the following is displayed. IP addresses are for demonstration purposes only. Actual
addresses will differ in each application.
lo0: flags=849<UP,LOOPBACK,RUNNING,MULTICAST> mtu 8232
inet 127.0.0.1 netmask ff000000
hme0: flags=863<UP,BROADCAST,NOTRAILERS,RUNNING,MULTICAST> mtu 1500
inet 172.24.235.53 netmask ffffff00 broadcast 172.24.235.255
ether 8:0:20:9a:76:6c
hme1: flags=863<UP,BROADCAST,NOTRAILERS,RUNNING,MULTICAST> mtu 1500
inet 172.24.237.53 netmask ffffff00 broadcast 172.24.237.255
ether 8:0:20:9a:76:6c
The configuration of additional Ethernet interfaces is now complete. Proceed to Installing the Alarm
Software section on page 2-46.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-46
OL-1150-15
Chapter 2
Sun Fire V210, Netra 240 and Netra 440, refer to the SUN ALOM Guide at
http://www.sun.com/servers/alom.html. Proceed to the Installing the Solaris 8 Patch Cluster
(CSCOh015) section on page 2-51.
Note
If your system is using Sun Fire V210 platforms as PGW hosts, be aware that a log message indicating
that the LOM package has not been installed is generated every time you start the Cisco MGC software.
You can ignore this message. The message is similar to the following:
Tue Jan 31 12:10:44:936 2006 EST | AlarmManager (PID 4176) <Error>
MGMT_ERR_LOM_NOT_INSTALLED: The LOM package for NETRA not installed
For all other platforms, use the procedure in the following section, Installing Lights Out Management
Software.
Step 1
Netra t 1400/1405
Netra t 100/105
Netra 120
Netra 20
Load the Software Supplement for the Solaris 8 Operating Environment 10/01 CD-ROM into the
CD-ROM drive. Install the Lights out Management software by entering the following commands at the
# prompt.
# cd /cdrom/cdrom0/Netra_Lights_Out_Management_2.0/Product
# pkgadd -d .
A screen similar to the following is displayed along with copyright and trademark information:
The following packages are available:
1 SUNWlomm
LOMlite manual pages
(sparc) 2.0,REV=2000.08.22.14.14
2 SUNWlomr
LOMlite driver (root)
(sparc) 2.0,REV=2000.08.22.14.14
3 SUNWlomu
LOMlite Utilities (usr)
(sparc) 2.0,REV=2000.08.22.14.14
Select package(s) you wish to process (or 'all' to process
all packages). (default: all) [?,??,q]:
Step 2
Press Enter to accept the default answer of all and install all the packages. A screen similar to the
following is displayed:
Processing package instance <SUNWlomm> from
</cdrom/solaris8_1000_suppcd/Netra_t_Lights_Out_Management_2.0/Product>
LOMlite manual pages
(sparc) 2.0,REV=2000.08.22.14.14
Copyright 2000 Sun Microsystems, Inc. All rights reserved.
Using </> as the package base directory.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-47
Chapter 2
Step 3
Type y and press Enter to continue the Netra t Lights Out Management installation. A screen similar to
the following is displayed:
Installing LOMlite driver (root) as <SUNWlomr>
## Installing part 1 of 1.
10 blocks
i.drivers: INFO: Starting ...
i.drivers: Adding
/cdrom/solaris8_1000_suppcd/Netra_t_Lights_Out_Management_2.0/Product/SUNWlomr/reloc/platf
orm/sun4u/kernel/drv/lom
i.drivers: Adding
/cdrom/solaris8_1000_suppcd/Netra_t_Lights_Out_Management_2.0/Product/SUNWlomr/reloc/platf
orm/sun4u/kernel/drv/lomp
i.drivers: Adding
/cdrom/solaris8_1000_suppcd/Netra_t_Lights_Out_Management_2.0/Product/SUNWlomr/reloc/platf
orm/sun4u/kernel/drv/sparcv9/lom
i.drivers: Adding
/cdrom/solaris8_1000_suppcd/Netra_t_Lights_Out_Management_2.0/Product/SUNWlomr/reloc/platf
orm/sun4u/kernel/drv/sparcv9/lomp
Identified drivers: lom lomp lom lomp
i.drivers: Installing drivers ...
Driver: lom ... devlinks ... add_drv(1M) ...
Driver: lomp ... devlinks ... add_drv(1M) ...
Driver: lom ... devlinks ... add_drv(1M) ...OK ...
Driver: lomp ... devlinks ... add_drv(1M) ...OK ...
i.drivers: Finished
[ verifying class <drivers> ]
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-48
OL-1150-15
Chapter 2
Step 4
Type q and press Enter when the Netra t Lights Out Management installation has completed.
Step 5
Eject the CD from the CD-ROM drive by entering the following commands:
# cd /
# eject
Step 6
Note
If you have installed the Solaris DiskSuite package (CSCOh016) on your system, the messages
below are displayed during system boot-up. They are normal Solaris DiskSuite start-up
messages and do not indicate any problem with your system.
WARNING force load of misc /md-trans failed
WARNING force load of misc /md-raid failed
WARNING force load of misc /md-hotspares failed
WARNING force load of misc /md-sp failed
Step 7
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-49
Chapter 2
The Lights Out Management installation is now complete. Proceed to Installing the Solaris 8 Patch
Cluster (CSCOh015) section on page 2-51
Load the Software Supplement for the Solaris 8 Operating Environment 10/01 CD into the CD-ROM
drive and enter the following commands:
# cd /cdrom/cdrom0/Netra_t11xx_Alarms_2.0/Product
# pkgadd -d .
Step 2
Step 3
Type y and press Enter to continue the installation. A screen similar to the following is displayed:
Installing TS91 Alarm and Monitor driver as <SUNWtsalr
...
Installation of <SUNWtsalr was successful.
Processing package instance <SUNWtsalu from </cdrom/netrat_11xx_1_0
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-50
OL-1150-15
Chapter 2
SUNWtsalm
SUNWtsalr
SUNWtsalu
Step 4
Step 5
Step 6
Note
If you have installed the Solaris DiskSuite package (CSCOh016) on your system, the messages
below are displayed during system boot-up. They are normal Solaris DiskSuite start-up
messages and do not indicate any problem with your system.
WARNING force load of misc /md-trans failed
WARNING force load of misc /md-raid failed
WARNING force load of misc /md-hotspares failed
WARNING force load of misc /md-sp failed
Step 7
This completes the Alarm Card software installation. Proceed to Installing the Solaris 8 Patch Cluster
(CSCOh015) section on page 2-51.
You must back up your system prior to installing the Solaris 8 Patch Cluster (CSCOh015). If you do not
back up and your disk is too full when you install this software, the script may fail and corrupt your disk.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-51
Chapter 2
Caution
Make sure that no earlier version of the Solaris 8 Patch Cluster (CSCOh015) is installed on the system,
otherwise the installation of the latest version of CSCOh015 may fail.
Note
Removing the Solaris 8 Patch Cluster (CSCOh015) does not remove the Solaris patches that were
installed when the /opt/sun_install/installPatches8 was executed during a previous patch installation.
However, if you install the package CSCOh015 and it contains a newer version of previously-installed
Solaris patches, the new version will supersede the older version. The older patches will remain on the
system, but stay inactive unless the newer patches are removed.
To determine the Solaris patch version in your system, use the command showrev -p. This command
will show both the old and new patch versions.
Note
Install the Solaris 8 Patch Cluster (CSCOh015) after Solaris DiskSuite and LOM software are installed
because some patches in CSCOh015 apply to DiskSuite and LOM.
If you are installing using the CD-ROM, load the Cisco Solaris 8 Patches CD into the CD-ROM drive.
Enter the following command:
# pkgadd -d /cdrom/cdrom0/CSCOh015.pkg
Step 2
Press Enter to accept the default response of all and continue. A screen similar to the following is
displayed:
Processing package instance <CSCOh0015> from </var/tmp/CSCOh0015.pkg>
Media Gateway Controller Solaris 8 Patch Cluster
(sparc) 1.0(3)
Cisco System, Inc.
The selected base directory </opt/sun_install> must exist before
installation is attempted.
Do you want this directory created now [y,n,?,q] y
Using </opt/sun_install> as the package base directory.
## Processing package information.
## Processing system information.
1 package pathname is already properly installed.
## Verifying disk space requirements.
## Checking for conflicts with packages already installed.
The following files are already installed on the system and are being
used by another package:
* /opt/sun_install <attribute change only>
* - conflict with a file which does not belong to any package.
Do you want to install these conflicting files [y,n,?,q] y
Step 3
Type y and press Enter to continue. A screen similar to the following is displayed:
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-52
OL-1150-15
Chapter 2
Step 4
Type y and press Enter to continue. A screen similar to the following is displayed:
Installing Media Gateway Controller Solaris 8 Patch Cluster as <CSCOh0015>
The system lists the patches that it will install. This list will vary over time. A screen similar to the
following is displayed:
.
## Executing postinstall script.
****************************************************
*
You must now change directories
*
*
to /opt/sun_install and run
*
*
./installPatches8
*
****************************************************
Installation of <CSCOh0015> was successful.
Step 5
Change directory to /opt/sun_install and run the installPatches8 script by entering the following
commands:
# cd /opt/sun_install
# ./installPatches8
Note
During the installation of the Solaris 8 patch cluster, some patches will fail with return codes 2,
8, and 35. This is normal and does not indicate a problem with the installation. The following is
an explanation of these error codes:
2 - Attempting to apply a patch that is already applied.
8 - Attempting to patch a package that is not installed.
35 - A later version of the patch has already been installed.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-53
Chapter 2
Step 6
The Solaris 8 patch cluster installation is complete. Reboot the target machine.
Note
If you used the CD-ROM drive to load the Solaris 8 patch cluster, eject the CD prior to rebooting.
Note
If you have installed the Solaris DiskSuite package (CSCOh016) on your system, the messages
below are displayed during system boot-up. They are normal Solaris DiskSuite start-up
messages and do not indicate any problem with your system.
WARNING force load of misc /md-trans failed
WARNING force load of misc /md-raid failed
WARNING force load of misc /md-hotspares failed
WARNING force load of misc /md-sp failed
Caution
Note
Solaris 8 should be installed on the primary disk with the partition information described in Table 2-3
on page 2-22, Table 2-5 on page 2-23, or Table 2-7 on page 2-24.
Make sure the Solaris 8 recommended patches are installed (Cisco package CSCOh015.pkg).
Reboot the system.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-54
OL-1150-15
Chapter 2
Note
If you have installed the Solaris DiskSuite package (CSCOh016) on your system, the messages
below are displayed during system boot-up. They are normal Solaris DiskSuite start-up
messages and do not indicate any problem with your system.
WARNING force load of misc /md-trans failed
WARNING force load of misc /md-raid failed
WARNING force load of misc /md-hotspares failed
WARNING force load of misc /md-sp failed
Note
Currently, all patches required for Raid Manager 6.22.1 are included in the Solaris 8 07/01 and later
releases, as well as the Cisco Patch package CSCOh015.
After the Raid Manager is installed, you must reboot the system.
Note
If you have installed the Solaris DiskSuite package (CSCOh016) on your system, the messages
below are displayed during system boot-up. They are normal Solaris DiskSuite start-up
messages and do not indicate any problem with your system.
WARNING force load of misc /md-trans failed
WARNING force load of misc /md-raid failed
WARNING force load of misc /md-hotspares failed
WARNING force load of misc /md-sp failed
Note
There is no CLI available to configure the RAID module. To configure the RAID module remotely over
the network, you must access the Sun box through a graphic adapter and a monitor.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-55
Chapter 2
Verifying/Upgrading Firmware
Check and update the RAID Module firmware as required. If the firmware is not at least version 3.0, it
will need to be updated. Refer to the Installation and Support Manual, page 44, for installation
instructions, and page 122 for the correct version information. Perform a RAID Module health check
after the firmware is upgraded. Refer to the Installation and Support Manual, page 48, for health check
procedures.
Configuring LUNs
The array should be configured with 2 LUNs. LUN0 should consist of three 36 GB drives and be
configured with RAID 0 format. It will be used for /opt/CiscoBAMS/CDR/archive. LUN1 should be
configured with five 36 GB drives and be configured with RAID 0. It will be used for
/opt/CiscoBAMS/data.
You should first delete existing LUNs (refer to page 44 of the User Guide). Create new LUNs (refer to
page 69 of the User Guide). The configuration should be set up as listed above.
Note
Do not exit the configuration without creating at least LUN 0. If you exit without creating LUN 0, you
will not be able to access the RAID module!
After LUNs have been created, perform a health check using the GUI Recovery Guru/Health Check
Menu. This function should pass without any errors. For information, see page 48 of the Installation and
Support Manual.
Note
Step 1
For the device names for each platform type, refer to Table 2-2 on page 2-4 (Device Names on Supported
Cisco MGC Software Platforms).
Use the following command and verify that you have 2 LUNs and check the approximate disk sizes
(shown in the text display):
/usr/lib/osa/bin/raidutil -c c1t5d0 -I
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-56
OL-1150-15
Chapter 2
Step 2
Make file systems on LUNs. Check the file systems and make mount points for disk volumes. Modify
the /etc/vfstab file and mount new disk volumes.
Step 3
Make the file system for /opt/CiscoBAMS/CDR/archive. Enter the following command:
newfs /dev/rdsk/c1t5d0s6
Step 4
Make the file systems for /opt/CiscoBAMS/data. Enter the following command:
newfs /dev/rdsk/c1t5d1s6
Step 5
Step 6
Make the mount points for the RAID volumes. Enter the following commands:
mkdir /opt/CiscoBAMS/data
mkdir /opt/CiscoBAMS/CDR/archive
Step 7
Add entries to /etc/vfstab for new RAID volumes. Enter the following commands:
echo /dev/dsk/c1t5d0s6 /dev/rdsk/c1t5d0s6 /opt/CiscoBAMS/CDR/archive
/etc/vfstab
echo /dev/dsk/c1t5d1s6 /dev/rdsk/c1t5d1s6 /opt/CiscoBAMS/data
- >> /etc/vfstab
Step 8
ufs 2
yes - >>
ufs
yes
Troubleshooting
Netra t 10x
Symptom:
Netra t 10x will not boot from the CD-ROM.
Solution:
At the ok prompt, type set-defaults to reset the OpenBoot PROM. Be sure to enter the environment
variable settings shown in Installing the Solaris 8 Operating System, page 2-15, Step 28, at the end of
the installation procedure.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
OL-1150-15
2-57
Chapter 2
Troubleshooting
If the target machine does boot to the hard disk drive, use the format command to delete the existing
partitions.
If the target machine does not boot to the hard disk drive, boot from the CD-ROM by typing
boot cdrom -s at the ok prompt. Follow the instructions to reformat the disk. This procedure takes
approximately 1.5 hours.
Cisco Media Gateway Controller Software Installation and Configuration Guide (Releases 9.1 through 9.6)
2-58
OL-1150-15