In synchroscope motor filed winding is suddenly open what happen for the circuit ?
It will stop

In the turbo alternator damper winding are not used why?
Ans:Turbo alternator had eddy current damping mechanism

Capacity of sabarigri ?
300MW

Highest transmission voltage in india?
400

What is buchholz relay ?
Ans:

The buchholz (gas/liquid operated) relay is connected in the pipe work between the transformer tank and the
conservator. If a valve is fitted to isolate the conservator, the buchholz relay is usually on the transformer tank
side of the valve.

http://www.tonysblog.in/assistant­engineer­interview­questions­4/ 1/2
8/17/2016 Important interview questions ­ KSEB

Under normal conditions, the relay is full of oil. Most faults occurring within oil filled transformers are
accompanied by the generation of gas by the oil, due to liberation of heat. Such generated gas accumulates in
the relay, thereby operating the float/flap switches.

With an incipient fault, gas is produced at a very slow rate and the upper float (alarm) switch will operate after a
specified volume of gas has accumulated. The upper float (alarm) switch will also indicate the low oil level of the
conservator.

When a major fault occurs, the gas is produced rapidly, resulting in a sudden surge of oil up to the conservator,
thereby operating the lower float (trip) switch. The lower float (trip) switch will also indicate the drained oil level of
the conservator.

Earthing connection of transformer
Ans:

The tank should be permanently and effectively connected to earth by means of flat, flexible conductor of
suitable size and materials (galvanized steel, copper, or acceptable equivalent) terminated on earthing terminals
or pads provided at the bottom of the tank, cable box, marshalling box, switch gear box, etc.

Earthing connection(s) with a good low resistance are essential for adequate protection against electrical faults.
All the earth connections should be of sufficient physical size to carry the line current for 30 seconds

Safety procedures during internal inspection and maintenance or repairs
Ans:

De­energize the transformer by disconnecting both High and Low Voltage lines. • Ground the terminal lines of
the transformer.
Place locks and warning cards stating that the interrupters or terminal boxes must not be operated (LOTO
procedures).
Disconnect the power supply of the control cabinet.

Before going inside to any transformer, verify that the internal environment contains a minimum of 19.5%
oxygen and maximum of 50 ppm CO for exposures up to 8 hours period. For further information, refer the
OSHA regulation. Utilize dry air (less than 0.05% impurities and – 58°F/­ 50a C or lower dew point) for flowing
through the transformer while inside the transformer tank.

Use only explosion proof lamps inside the tank and verify the insulation condition of the electrical cord – it must
be free of damage.

Dehydrating breather
Ans:

Plain pipe breather is generally sealed with cap for transit purpose and the same should be removed ONLY
during commissioning.