You are on page 1of 4

ABBREVIATIONS

RENR8077-01
December 2006

1
2
3
4
5
6
7

LOW
OIL
PRESSURE

LOW
FUEL
LEVEL

SYSTEM
NOT IN
AUTO

8
9
10
11
12
13
14

1
2
3
4
5
6
7

1
2
3
4
5
6
7

8
9
10
11
12
13
14

8
9
10
11
12
13
14

108

:A
:B
:C
:D
:E

108

33

LOW
BATTERY
VOLTAGE

110

:A
:B
:C
:D
:E

110

34

T13

LAMP
TEST

ALARM
SILENCE

19

159

F32
(2A)
F33
(2A)

(FRONT)

TERM. No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14

CONNECTION DESCRIPTION
WIRE No. 10 (GSC RM39) & HORN +VE
WIRE No. 90 (GSC 40 WAY No. 35) ALARM DATALINK
JUMPER TO 10
JUMPER TO 11
NOT CONNECTED
NOT CONNECTED
WIRE No. 30 (GSC RM27) & SILENCE SWITCH
LOW FUEL LEVEL SWITCHED -VE INPUT
NOT CONNECTED
LED 7 (SPARE)
LED 8 (SPARE)
LAMP TEST -VE INPUT (IF REQUIRED)
SILENCE SWITCH
HORN -VE

GENERATOR SET CONTROL

ATB

AC TRANSFORMER BOX

HET

HIGH ENGINE TEMPERATURE

CR

CONTROL RELAY

HOT

HIGH OIL TEMPERATURE

CTR

CRANK TERMINATION RELAY

KW

KILOWATT

EGR

ELECTRONIC GOVERNOR RELAY

LCL

LOW COOLANT LEVEL

FCR

FUEL CONTROL RELAY

LOP

LOW OIL PRESSURE

GFR

GENSET FAULT RELAY

POT

POTENTIOMETER

GPHI

GROUND POST HIGH

SCR

SCREEN

GPLO

GROUND POST LOW

SMR

STARTER MOTOR RELAY

154

156

SYMBOLS

42

43

3406C & 3456 Generator Set


with EMCP II+
Electrical System

(REAR)

GSC

:2

FUSE

(FRONT)

(REAR)

(REAR)
NOTE ON SYNC MODULE:
FOR 208V SYSTEM 108 &
FOR 240V SYSTEM 108 &
FOR 300V SYSTEM 108 &
FOR 380V SYSTEM 108 &
FOR 400V SYSTEM 108 &
FOR 415V SYSTEM 108 &
FOR 480V SYSTEM 108 &
FOR 600V SYSTEM 108 &

TERM. No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14

W
36

157

(FRONT)

18

35

159

:6/:L3

157

:4/:L1

ALARM
SILENCE

AIR SHUT-OFF RELAY

T11

SLR/2

LOW
COOLANT
TEMP

SLR/1

HIGH
COOLANT
TEMP

ASR

CONNECTION DESCRIPTION
WIRE No. 10 (GSC RM39) & HORN +VE
WIRE No. 90 (GSC 40 WAY No. 35) ALARM DATALINK
LED 5 SWITCHED -VE INPUT
LED 6 SWITCHED -VE INPUT
LED 7 SWITCHED -VE INPUT
LED 8 SWITCHED -VE INPUT
WIRE No. 30 (GSC RM27) & SILENCE SWITCH
LED 1 SWITCHED -VE INPUT
LED 2 SWITCHED -VE INPUT
LED 3 SWITCHED -VE INPUT
LED 4 SWITCHED -VE INPUT
LAMP TEST
SILENCE SWITCH
HORN -VE

110
110
110
110
110
110
110
110

SHOULD
SHOULD
SHOULD
SHOULD
SHOULD
SHOULD
SHOULD
SHOULD

CONNECTED
CONNECTED
CONNECTED
CONNECTED
CONNECTED
CONNECTED
CONNECTED
CONNECTED

TO
TO
TO
TO
TO
TO
TO
TO

RESISTOR PIN D
RESISTOR PIN C
RESISTOR PIN B
RESISTOR PIN B
RESISTOR PIN B
RESISTOR PIN A
RESISTOR PIN A
SINGLE RESISTOR

EMERGENCY STOP PUSHBUTTON

PANEL LAMP

11

CHASSIS CUSTOMER TERMINAL

11

CHASSIS DC TERMINAL

CHASSIS AC TERMINAL

:10
R

RELAY COIL

:2

TRANZORB

SR4B Generator:
L5A1-UP
L6B1-UP
L7A1-UP

3456 Gen Set:


C1G1-UP
C2T1-UP
C3G1-UP
C4G1-UP

POTENTIOMETER

:1

DOOR TERMINAL

28

SCREEN CABLE

58

RELAY CONTACT N/O

30

CHASSIS TO DOOR DC SOCKET

:1
R/1
:3

ENGINE SOCKET

CHASSIS TO DOOR AC SOCKET

:3

CONNECTION DESCRIPTION
WIRE No. 10 (GSC RM39)
WIRE No. 90 (GSC 40 WAY No. 35) ALARM DATALINK
LED 5 SWITCHED -VE INPUT
LED 6 SWITCHED -VE INPUT
LED 7 SWITCHED -VE INPUT
LED 8 SWITCHED -VE INPUT
WIRE No. 30 (GSC RM27)
LED 1 SWITCHED -VE INPUT
LED 2 SWITCHED -VE INPUT
LED 3 SWITCHED -VE INPUT
LED 4 SWITCHED -VE INPUT
LAMP TEST -VE INPUT (IF REQUIRED)
TERMINAL No. 13 ON 1st ALARM MODULE
(ALM MUTE)
TERMINAL No. 14 ON 1st ALARM MODULE
(HORN ON)

TERM. No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14

BE
BE
BE
BE
BE
BE
BE
BE

3406C Gen Set:


C2G1-UP
C5G1-UP
C8G1-UP

:3

PANEL LAMP SWITCH


:2
POWER TERMINAL

EARTH

:1

:2
:3
:4
:5

PWM MODULE

GSC RELAY MODULE TERMINAL


ENGINE CONTROL SWITCH
ATB TERMINAL

CIRCUIT BREAKER

1
9X9857

GSC 40 WAY HARNESS CONNECTOR

SPARE FAULT INPUT (LED 3)

:11

SPARE FAULT INPUT (LED 4)

:3

SPARE SHUTDOWN INPUT (LED 5)

:3

SPARE SHUTDOWN INPUT (LED 5)

:4

SPARE SHUTDOWN INPUT (LED 6)

:4

SPARE SHUTDOWN INPUT (LED 6)

:5

SPARE SHUTDOWN INPUT (LED 7)

:5

SPARE SHUTDOWN INPUT (LED 7)

:6

SPARE SHUTDOWN INPUT (LED 8)

SPARE SHUTDOWN INPUT (LED 8)


LAMP TEST
(IF REQUIRED)

(T11)

ATB +

EMCP II+
ATB

(T12)

WIRE TABLE

TBC

27
26

+B

H21
H22
H23

LEVEL SWITCH
(TOP VIEW)

H
H IG

PUMP
RUN

LOWW
LO

TERMINAL BOX

H
HIG

15

18

LOW
LEVEL
FUEL
SWITCH

LEVEL SWITCH
(SIDE VIEW)

TERMINAL BOX

21

:3
PR/1
:1
20

HIGH
LEVEL
FUEL
SWITCH

84

81

:6
PR/2

81

:7
SW4

NORMALLY OPEN

36

85

83

SW3

NORMALLY CLOSED

SW2

NORMALLY CLOSED

:2
MV
:1 MOT.
-VE SUPPLY

35
SW1

:2

PR
:10

LOW
LEVEL
FUEL
SWITCH

20

LEVEL SWITCH
(SIDE VIEW)

:3
PR/1
:1
20

HIGH
LEVEL
FUEL
SWITCH

TERMINAL BOX

:6
PR/2
:7
36

HIGH
LEVEL
FUEL
SWITCH

LEVEL SWITCH
(SIDE VIEW)

85
:2
MV
:1 MOT.

TERMINAL BOX

21

81

TERMINAL BOX

VALVE

83

:2

81

SW3

83

PR
:10

NORMALLY OPEN

NORMALLY CLOSED

SW2

NORMALLY CLOSED

SW1

NORMALLY CLOSED

+
-

-VE SUPPLY

SW4

T11

T2

T12

T3

T13

NORMALLY OPEN

SW3

NORMALLY CLOSED

SW2

NORMALLY CLOSED

F22
(2A)

PR
:10

13

COPPER
BUSBAR

AC CIRCUIT

F22
(2A)

:13
AUX
:14

24

203

208
23

10

203

208
PUMP
STOP

51

51

52

52

53

53

80

80

82

82

T5

HI

J1-5
BR

BK
16 GA BK

T6

HI

J1-6
BR

BK

BK

PU

13

:X1
PUMP
TRIP/
STOP
:X2

PUMP
RUN
:X2

14

O/L 1

97

98

96

23
2 .5 mm
FUEL
PUMP

2 .5 mm

208 211 131

A1

13

14

O/L 1

97

6 mm 2
46
131

72

NORMALLY OPEN

SW4

72

NORMALLY CLOSED

NORMALLY CLOSED

95

98

64

NOTE: CUSTOMER CABLE TO


ENTER DIRECTLY ONTO
6 mm 2 TERMINALS.

SW3

23
2 .5 mm

M
131

VA
AC
VB
AC
VC
AC

NSFORMERS,
SFORMERS

17

11

72

CONNECT TO ALARM MODULE SPARE


10

30
77

65

30

30

77

SW2

72
72

26

28

77

CONNECT TO ALARM MODULE SPARE

FUEL
PUMP

2 .5 mm

17

11

30

64

SW1

72

M
131

RELAY BOARD

SEL
GND
SEL
GND
SEL
GND

+BAT. SW
+BAT. UNFUSED
CTR IN
FCR IN
ASR IN
SMR IN
GFR IN
RR2 IN
RR1 IN
PSR1 IN
PSR2 IN
+BAT. FUSED OUT
EGC IN
EGC N/O OUT
FCR N/O OUT
CTR N/O OUT
CTR N/C OUT
SMR N/O OUT
ASR N/O OUT
ASR N/C OUT
SMR N/C OUT
GFR N/O OUT
RR1 N/C OUT
RR2 N/O OUT
PSR2 N/O OUT
PSR1 N/C OUT
FLYBACK GND
-BAT.

J1-1
J1-2
J1-3
J1-4
J1-5
J1-6
J1-7
J1-8
J1-9
J1-10
J1-11
J1-12
J1-13
J1-14
J1-15
J1-16
J1-17
J1-18
J1-19
J1-20
J1-21
J1-22
J1-23
J1-24
J1-25
J1-26
J1-27
J1-28

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

29
30
31
32
33
34
35
36
37
38
39

-B

:9
:11

64
29

65
30

66
31

FUSED DC
POSITIVE
CAT
DATA
LINK

72

CONNECT TO ALARM MODULE SPARE


10

FUEL
LEAK
SWITCH

30

38
:2
GRR
:10

65

LOW-LOW
FUEL
LEVEL
SWITCH

30

SP2

4
31
32

10

D+

D-

14

CMS

:8

31

GRR/3
:9

12

22

16

:11
56

87
32

17

LED BLANK
WATCHDOG LED
+5V
+12V
SERIAL CLOCK
SERIAL STROBE
SERIAL DATA
GROUND

ALR/3
:8

REMOTE CONTACTS
FOR GENERAL ALARM

45

24

W2-1
W2-2
W2-3
W2-4
W2-5
W2-6
W2-7
W2-8

NOTE A: THE RANGE SELECT JUMPER IS INSTALLED IN


ALL CONTROLS TO SELECT THE DEFAULT 0-700V
INPUT RANGE. REMOVAL OF THE JUMPER SELECTS
0-150V INPUT RANGE.

:2
ALR
:10

LOW
FUEL
LEVEL
SWITCH

96

NORMALLY CLOSED

24

AC GND

211 209 210

211 209 210


N

131

204

A2
131

131

95

J2-1
J2-2
J2-3
J2-4
J2-5
J2-6

AC GND

18 GA GY

W1-1
W1-2
W1-3
W1-4
W1-5
W1-6
W1-7
W1-8

NOTE:
IF NO ALARM MODULE FITTED THEN
RELAY WILL ACTIVATE ON SHUTDOWN ONLY.

PC

2 .5 mm

A2
131

J1-7

J1-8

AC GND
+12V
VB SEL
+12V
VA SEL
NC
VC SEL
NC
EGC DRIVE
RR DRIVE
CTR DRIVE
ASR DRIVE
PSR DRIVE
GFR DRIVE
SMR DRIVE
FCR DRIVE
+BAT. SW
+BAT. SW
GROUND
GROUND

IC

18 GA BR

KEYPAD

LED BOARD
LED BLANK
WATCHDOG LED
+5V
+12V
SERIAL CLOCK
SERIAL STROBE
SERIAL DATA
GROUND

RANGE
SELECT
JUMPER
NOTE A

204
:X1

AC GND
+12V
VB SEL
+12V
VA SEL
VA BUS SEL
VC SEL
VC BUS SEL
EGC DRIVE
RR DRIVE
CTR DRIVE
ASR DRIVE
PSR DRIVE
GFR DRIVE
SMR DRIVE
FCR DRIVE
+BAT. SW
+BAT. SW
GROUND
GROUND

16 GA BK
16 GA BK

+12V
GROUND
SERIAL CLOCK
SERIAL DATA
KEYPAD PWR 1
KEYPAD PWR 2
KEYPAD ROW 1
KEYPAD ROW 2
LED BLANK
NC
SERIAL STROBE
WATCHDOG LED
KEYPAD ROW 3
KEYPAD ROW 4
NC
NC

W3-1
W3-2
W3-3
W3-4
W3-5
W3-6
W3-7

+B

18 GA GY

72

:95
O/L
:96

6 mm

A1

208 211 131

2 .5 mm

204

J3-1
J3-2
J3-3
J3-4
J3-5
J3-6
J3-7
J3-8
J3-9
J3-10
J3-11
J3-12
J3-13
J3-14
J3-15
J3-16
J3-17
J3-18
J3-19
J3-20

PU

BK

16 GA BK

:9

NOTE: CUSTOMER CABLE TO


ENTER DIRECTLY ONTO
6 mm 2 TERMINALS.

IB

18 GA BR

206

6 mm 2
46
131

PC

50

PU

BK
18 GA BK

131

204

131

50

18 GA BK

PR/3
:11

2.5 mm

:95
O/L
:96

:X2

50

IA

18 GA BR

12
205

:9

206

PUMP
RUN

203

21

PR/3
:11

:X1
PUMP
TRIP/
STOP
:X2

H23

50

J1-4
BR

22

202

12
205

:X1

H23

T4

HI
BK

18 GA BK

AC SUPPLY
CUSTOMER
100V TO 250V

23

22

203

H22

T1, T2 AND T3 ARE 15:1 POTENTIAL TRA


T4, T5 AND T6 ARE 500:1 CURRENT TRAN

11
J

18 GA RD

X2

205

21

HIG

X1

VC

J3-1
J3-2
J3-3
J3-4
J3-5
J3-6
J3-7
J3-8
J3-9
J3-10
J3-11
J3-12
J3-13
J3-14
J3-15
J3-16
J3-17
J3-18
J3-19
J3-20

24

205

202

LOW

SW3

H21

H22

207

6 mm

SW2

J1-3

MAG PU IN
MAG PU GND
I NEUTRAL IN
IA IN
IB IN
IC IN
COOLANT TEMP SNSR IN
OIL PRESS. SNSR IN
+V SNSR OUT
VA GEN IN
VB GEN IN
VC GEN IN
COOLANT LOSS IN
OIL TEMP SNSR IN
AUTO SYNC
AC GND
VA BUS IN
VC BUS IN
CAT DATA LINK+
CAT DATA LINKCCM DATA LINK+
CCM DATA LINKSPARE FAULT SW1 IN
SPARE FAULT SW2 IN
SPARE FAULT SW3 IN
SYNC CHECK
SPEED ADJUST1
SPEED ADJUST2
SPARE FAULT SW4 IN
RDM DATA OUT
SENSOR GND
STOP SW IN
START/RUN SW IN
KW RELAY OUT
ALM DATA OUT
SPARE DATA OUT
CLOSE BREAKER OUT
EMER STOP SW IN
OFF/RESET SW IN
AUTO. SW IN

TERMINAL BOX

:97
O/L
:98

202

AC SUPPLY
CUSTOMER
100V TO 250V

11
PUMP
STOP

SW1

2 .5 mm

202
10

F21
(6A)

:97
O/L
:98

CABLE ENTRY

H21

mm
2.5

:13
AUX
:14

6 mm
45
132

LOWW
LO

13

207
M

SW4
2

VB

18 GA RD

X2

H2

10-POLE
TERMINAL
STRIP

J1-2
X1

H1

:2

VA

18 GA RD

X2

T2

NORMALLY CLOSED

AC CIRCUIT

F21
(6A)

H2

T3

HI
HIGGHH

AC CIRCUIT

18 GA BK

8-PIN
DEUTSCH
CONNECTOR
J1-1

X1

H2

SW1

AC CIRCUIT

6 mm
45
132

H1

18 GA BK

LEVEL SWITCH
(TOP VIEW)

COPPER
BUSBAR

T1
18 GA BK

H1

35

NORMALLY CLOSED

ATB +
INTERNAL SCHEMATIC

3-POLE
FUSE BLOCK

T1

35

SW4

VALVE

ALREADY
FITTED AS
STANDARD

18

:3
PR/1
:1

LOW

H
HIG

J1-1
J1-2
J1-3
J1-4
J1-5
J1-6
J1-7
J1-8
J1-9
J1-10
J1-11
J1-12
J1-13
J1-14
J1-15
J1-16
J1-17
J1-18
J1-19
J1-20
J1-21
J1-22
J1-23
J1-24
J1-25
J1-26
J1-27
J1-28
J1-29
J1-30
J1-31
J1-32
J1-33
J1-34
J1-35
J1-36
J1-37
J1-38
J1-39
J1-40

HC5

ALREADY
FITTED AS
STANDARD

21

LOW
LEVEL
FUEL
SWITCH

TERMINAL BOX

LOWW
LO

84

82

J1-1
J1-2
J1-3
J1-4
J1-5
J1-6
J1-7
J1-8
J1-9
J1-10
J1-11
J1-12
J1-13
J1-14
J1-15
J1-16

HC4

15

LOW

ENTRY

82

ENTRY

J2-1
J2-2
J2-3
J2-4
J2-5
J2-6
J2-7
J2-8
J2-9
J2-10
J2-11
J2-12
J2-13
J2-14
J2-15
J2-16

HC3

LOW

SW1

SW1

SW3

+12V
GROUND
SERIAL CLOCK
SERIAL DATA
KEYPAD PWR 1
KEYPAD PWR 2
KEYPAD ROW 1
KEYPAD ROW 2
LED BLANK
KEYPAD PWR 3
SERIAL STROBE
WATCHDOG LED
KEYPAD ROW 3
KEYPAD ROW 4
NC
+12V REG

HC1

LOWW
LO

84

SW2

80

KEYPAD SIG X7
KEYPAD ROW 2
KEYPAD PWR 1
KEYPAD SIG 1X
KEYPAD ROW 3
KEYPAD ROW 4
KEYPAD PWR 2

CPU BOARD

HC2

PUMP
RUN

S W2

SW3

80

CABLE

SW4

CABLE

SW4

ENTRY

53

HI
HIGGHH

DISPLAY BOARD

SW1

SW3

SW2

16

CABLE

SW4

84

84
HI
HIGGHH

GSC EMCP II+

LINE A CURRENT
LINE B CURRENT
LINE C CURRENT
LINE A VOLTAGE
LINE B VOLTAGE
LINE C VOLTAGE
ELECTRONIC GOVERNOR CONTROL
PRE-LUBE PUMP
AIR SHUT-OFF RELAY
CRANK TERMINATE RELAY
FUEL CONTROL RELAY
GENSET FAULT RELAY
PROGRAMMABLE SPARE RELAY
RUN RELAY
STARTING MOTOR RELAY
PROGRAMMABLE SPARE RELAY
GENERATOR
CURRENT

HC0

16

52

84

HI
HIGGHH

51

PRI

84

LEVEL SWITCH
(TOP VIEW)

LEVEL SWITCH
(TOP VIEW)

ALREADY
FITTED AS
STANDARD

IA
IB
IC
VA
VB
VC
EGC
PP
ASR
CTR
FCR
GFR
PSR
RR
SMR
PSR
GEN
I

50

PRI

ALREADY
FITTED AS
STANDARD

DC CIRCUIT

(2A)

DC CIRCUIT

84

PRI

(2A)

PRI

ABBREVIATIONS

50

PRI

DC CIRCUIT

84

(2A)

50

1 F23

1 F23

PRI

1 F23

2 .5 mm

88
33

89
34

REMOTE CONTACTS
FOR GENERATOR RUNNING

DC NEGATIVE

51

52

57
53

54

HARNESS CODE 18

55

33 CLR
23 SRV
SCROLL
SWITCH
`SS'

:3
:2

MODE/
CLEAR
SWITCH
`MCS'

:1

:3 :6
:2

:4
:5

30 Page

GRAVITY FUEL SUPPLY FROM HIGH LEVEL BULK TANK TO BASETANK


FUEL SYSTEM No. 2

FUEL PUMPED FROM FREE STANDING BULK TANK


FUEL SYSTEM No. 3

BK
BK
BK
BK
BK
BK
BK
BK
BK
BK

PUMPED FUEL SUPPLY FROM BELOW FLOOR LEVEL BULK TANK TO BASETANK
FUEL SYSTEM No. 1

COLOR

RENR8077-01 VOL 1

(T13)

T11
T12
T13
H21
H22
H23
50
51
52
53

25

T11
T12
T13
H21
H22
H23
50
51
52
53

24

CIRCUIT
NO.

TERMINAL

23

38

22

20

21

:12

20

:2

19

90

18

17

17

ALARM
DATALINK

-B

DATALINK

:6

39

17 ALARM

:13

38

90

68

37

:2

:13

ALARM MUTE

Printed in U.S.A.

2006 Caterpillar
All Rights Reserved

36

DC

35

:7 -

34

:1 +

33

10
30

+B

32

31

:12

FIRST
ALARM
MODULE

SPARE FAULT INPUT (LED 4)

30

:13

LAMP TEST
(IF REQUIRED)

38

SPARE FAULT INPUT (LED 3)

:11

DC

Volume 1
-B

14

20

:12

SPARE FAULT INPUT (LED 2)

:10

:10

13

:2

SILENCE
SWITCH

LAMP
TEST

:7 -

:9

12

LOW FUEL LEVEL

10

:1 +

SPARE FAULT INPUT (LED 1)

SPARE FAULT INPUT (LED 2)

:14

11

72

30

:13
90

10

SPARE FAULT INPUT (LED 8)

:8

:9

HORN ON

10

LINK

:8

SILENCE
SWITCH
17

:4
:11

DC

:14

SPARE FAULT INPUT (LED 1)

:7 -

69

:8

:1 +

:14

10

SPARE FAULT INPUT (LED 7)

:10
30

HORN

LINK

ALARM
DATALINK

:3

:14

HORN

17

16

15

14

13

12

11

10

4 POLE BREAKER OPTIONAL


METERING C.T.S

VOLTS ADJUST
POTENTIOMETER
(1KW, 1 TURN)

T1

P1

P2

T2

S1
P1

S2
P2

CT1

T3

S1
P1

S2
P2

CT2

S1

S2

CT3

:2
80

:3

:1

L1
L2

72

10

L3

73

11

82

74

12

75

13

51

52

53

50

50

50

T1

T2

T3

101

76

14

REF.
F14

1
A
8

10

97

82

55

93

52

53

50

LINK

LINK

T1

T2

T3

J1-5

H23
F11
(2A)

H21
F12
(2A)

H22
F13
(2A)
T13

AC TRANSFORMER BOX
(ATB)

101

T12

101

110

110

109

109

108

108

J1-2
T11

91

1. IF THE FAULT SHUTDOWN INDICATOR IS


FLASHING THEN THE LINK SHOULD BE
TEMPORARILY FITTED.
THE GSC SETPOINTS
MUST BE PROGRAMMED IN OFF/RESET WHEN
A FAULT SHUTDOWN IS ACTIVE.
IF THE
FAULT ALARM INDICATOR IS FLASHING THE
GSC CAN BE PROGRAMMED WITH THE CONTROL
SWITCH IN ANY POSITION.

LINK

J1-6

J1-3

92

91

51

J1-4

93

92

94

56

57

95

94

J1-7

81

15

J1-8

96

95

16

97

96
80

98

J1-1

84

16

MOT1

27

MOT2

28

30 31

82
35

36

NOT
CONNECTED

27

4
29

25

26

18

67

61

15

99

12

14

63

90

43

35

13

217

18

RM
31

B+

470 ohm
POT
ST4

POST

RM
33

RM
30

RM
35

RM
32

RM
1

RM
2

RM
34

RM
36

FCR

218
P

52

CCM+

CCM-

RM
23

17

90

99
34

63

51

50

F2
(10A)

F3
(10A)

F1
(10A)

F6
(10A)

RM
4

RM
8

FCR

CTR

F4
(10A)

RM
6

RM
3

RR

SMR

CTR

RM
12

17
18
SPARE
SPARE

F5
(10A)

F7
(10A)

31
54

29
23
30
24

11

64
22

ATA+

ATA-

65
23

ATA-

SCR

39

40

RM
5

D-

D+

202

21

203

D+

47

26

15

D-

22

21

37

CCM-

GFR

ASR

19

30
RDM

D-

20

EGR

RM
15

2
2.5 mm 2

RM
24

13

RM
13

RM
16

RM
17
39

20

41

38

37

RM
14

39

30

41

207

D+
131

DATA LINK

117

97

16
6

220

25

96
95

5
4

93

12

402

26

94

108

33

92

11

91

10
RM
22

110

34

37

35
5

159

36

37

157

37

J
K
L
M
N
O

R
S
T
U
V
W

202
203
205
207
131
117
220
402
108
110
157
159

8
9
10
11

7
6

14
15
3
5

16
17

10

AUX. ALARMS/SHUTDOWNS
SWITCHED -VE
POST
B-

RM
18
14

17

38

205

23

20

RM
19

GPLO
RM
38
28

21

24

GPHI
RM
27

19

RDM

LOW OIL PRESSURE


EMERGENCY STOP
HIGH WATER TEMPERATURE
ENGINE OVERSPEED
OVERCRANK
(SPARE 1)
LOW COOLANT LEVEL
HIGH OIL TEMPERATURE
(SPARE 2)
SPARE 3
FAULT SHUTDOWN
FAULT ALARM

SET OP6 SETPOINT SP17 TO 6


SET OP6 SETPOINT SP18 TO 7

F10
(10A)
1

20

437

GENERATOR SET CONTROL (GSC)

RM
9

RM
7

RM
21

+
1

RM
39

26A

21

10

V-

V+

31

HET
7

LOP
8

LCL
13

23

22

24

SP1

43

62

16

67

15

25

SP2

SP3

41

40

39

29
SP4

42

40

55

42

33

56

32

57

37
7

58

19

18

59
F14
(10A)

2.5 mm

2.5 mm

CB2
(20A)

29

24
+

28
PS1

SMMS1/1

PS2

SMMS2/1

25

SM1

PS1

26

SM2

CB1
(60A)
:30
1FCR/1
:87
:30
2FCR/1
:87

15

6 mm 2

11

PS2

FCS

23

24

PANEL
LIGHT
SWITCH

42

38

:3
:2

40

54

45

EMER.
STOP

2
40

38

11

:11

20

41

30

17

34

26A

46

45

55

34

56

44

37

36

49

59

60

22

21

SP1
16

61

SP2

62

17

SP3
18

63

:1

19

39

22

41

66

62

53

67

16

15

67

62

18

67

62

19

67

REF.
L07

CHASSIS
DOOR
BODY

27

50

28

29

16

ASOR+

SD-PWR

SD-RTN

23A

22

10
23A

PANEL
LIGHTS

57

62

3
6 mm 2

P1/2

CHARGING
ALTERNATOR

OFF/RESET
AUTO
START
COOLDOWN/STOP

CONTROL MODE
SWITCH

30

:9
ALT

:2
:3
:4
:5

SP4

10

25

CR/3

27

KEY
REMOVABLE

37

30

30

57

38

9
8

ES-

EF1

59

EF2

12

E
7

E
2
2

11

12

2
2

ASOR+
51

SD-PWR
52

23A

SD-RTN
53

23A
9

3
12
6

11

47

41

46

41

15

65

10

16

30

30

20

25

17
48

34

45A

46

49

50

18

17

ES-

10

45

27

28

21

59
59

31

D
NOT CONNECTED

30

30

:10
CR
:2

NOT CONNECTED

NOT CONNECTED

21

NOT CONNECTED

22
32

22

33

62T

67T

42

43

62

67T

16

15
14

16

67P

62P

18

67L

62L

13

44

45

20

21

19

15

67P

18

67L

62L

62

19
23

19

67O

67O

EF2

D-

D+

61

62

EF1

EF2

EF1

62O

24

22

62O

NOT CONNECTED

30

IF REQUIRED

FIT IF REQUIRED

59

30

30

46

12

11

46

34

64

72

59

EMER.
STOP
ON
ENCLOSURE

62
1

67T
A

16

15

67P

EF1

62
B

EF2

59
MAGNETIC
PICK UP No.1

COOLANT
TEMPERATURE

4
3

SMMS1

:86
1FCR
:85

SMMS2

OIL
PRESSURE

COOLANT
LOSS
IF REQUIRED

60

:86
2FCR
:85

DIAGRAM-WIRING
(EMCP II+)

SASV

SATS

235-0829

OIL
TEMPERATURE
CORE BALANCE
CURRENT TRANSFORMER
IF REQUIRED

IF REQUIRED

DIAGRAM-WIRING
(ENGINE SCHEMATIC)

LOW
FUEL
LEVEL
SWITCH

236-5745

30

A
2

IF REQUIRED

VOLUME 1
3406 WITH EMCP II+

FIT IF REQUIRED
IF REQUIRED

18

21

19

19

RR

SMR

46

426

CCM+

36
SPARE

35
ALARM

KW

45

416

AVR

30 Page, B&W

MOT2

21

32

31

RDM

CCM DATALINK

R448

RENR8077-01 VOL 1

MOT1

20

J
20

17

61

ATA+

84

15

D-

22

BATTERY
ISOLATOR
SWITCH

58

81

14

:2
KWR
:10

48

SEE NOTE A

57

76

13

D+

13

(OPTIONAL)

46

:8
:9
:10

AUTO
START
COOLDOWN/STOP

24V

18

75

12

OFF/RESET

P2/2

6 mm

33

74

11

D-SPD

CONTROL
MODE SWITCH

32

73

S-SPD

:6

25

72

10

24

31

71

32

37

17

29

30

80

71

17

16

15

14

13

12

11

10

4 POLE BREAKER OPTIONAL


(SEE NOTE REF.A02)

T1

T1

T2

T2

T3

T3

E
406

3RD PHASE, FOR 480V USE TRANSFORMER

F42
(6A)

REF.
BBB

407

111B

111A

158

157

NOTE: ADD FUSE F41,


REMOVE LINK AND
CONNECT WIRE 111A
TO 3RD PHASE IF
VOLTAGE IS 240V L-L

410
B

158

F41
(6A)

111

NEUTRAL, REFER TO
BREAKER DRAWING

410

:1

402

402

:5

117
B

159A

159

159

:1
:3
UVT/1

BCR/1

:9

SPARE

:10

SPARE

:11

157

F32
(2A)

F40

178A

178A

117

POWER
WIRING FROM
GENERATOR

:C1

233

:14

231

:12

232

:11

111

BUS
TRANSFORMER
BOX
(BTB+)

22

231

:11

:12

233

:13

:14

B12
17

98

:2
BCR
:10

:14

:1

:7

10

90

WHITE
ORANGE

414
BREAKER
OPEN
219

30

10

17

REF.
AAA
REF.
BBB

:5

:86
EPIR
:85

:3

415

24

30

29

37

REF.
CCC

38

145

35

:86 AIR
ASOR
SHUT-OFF
:85 RELAY

SASV

37

FV
5

3406C

40

11

3 :2

ETHER
START
SWITCH

13

59

416

426

46

MOT2
203

24

MOT2
201

203

201

NOTE B: CONNECT TO NEGATIVE ON STARTER MOTOR OR BATTERY ISOLATOR

CANOPY LIGHTING

INLET AIR TEMPERATURE


SENSOR (P89)
(YELLOW SLEEVE)

TDC PROBE CONN (J26)

BACKUP SPEED/TIMING
SENSOR (P44)
GROUND
TDC PROBE
CONN (P26)
ECM CONN (P2)

COOLANT TEMP
SENSOR (P21)
COOLANT FLOW
SWITCH (P47)

OIL PRESSURE
SENSOR (J22)

59

ACT+

BREAKER AUXILIARY/1
REF. A03 BREAKER DRAWING

ACTUATOR

SASV

ACTMPU-

3
2

5
7

:14 :13 :15

SASV - START AID SOLENOID VALVE


SATS - START AID TEMPERATURE SWITCH

-VE SUPPLY

:11

35

FUEL TEMP
SENSOR (P43)
(BLACK SLEEVE)

:2
:1

SPEED ADJUST
POTENTIOMETER
(2K W, 10 TURN)

START AID OPTIONS

ENGINE LEFT SIDE

ATM PRESSURE
SENSOR (J27)

36

Volume 2

3456 ENGINE COMPONENT LOCATIONS


Printed in U.S.A.

2006 Caterpillar
All Rights Reserved

437

48

ECM CONN (P1)

:3

14

WOODWARD
ELECTRONIC
LINK FUEL
GOVERNOR
(ISOCHRONOUS)

12

MAGNETIC
PICK UP No.2

13

LINK

11
2

42

ENGINE RIGHT SIDE

43

221

47

206

58

UNIT INJECTOR (P91)

54

SYNCHRONISE
SWITCH
:6

6A FUSE

TURBO OUTLET PRESSURE


SENSOR (J23)

AIR SHUT-OFF OPTIONS

10

:1

SR4B Generator:
L5A1-UP
L6B1-UP
L7A1-UP

44

SATS

:4 :5 :8 :10

MOT2

PRIMARY SPEED/TIMING
SENSOR (P20)

15
219

3456 Gen Set:


C1G1-UP
C2T1-UP
C3G1-UP
C4G1-UP

37

:1

60

30

MOT1

NOTE A: CONNECT TO POSITIVE ON STARTER MOTOR

GENERATOR
SYNCHRONISING
MOTOR

59

40

:2
GCR
:10

:2
ALR
:10

BREAKER
CLOSE

30

28

-VE SUPPLY

SASV - START AID SOLENOID VALVE

46

218

14

(OPTIONAL)
FLAP
VALVE

23A

NOTE:B

54

:13
BKRR
:14

26A

:9
BUSR/1
:1
144

41

3406C Gen Set:


C2G1-UP
C5G1-UP
C8G1-UP

:87

59

MPU+
217

(16A)

ASOR/1

25

30

:30

59

:11

:4
BKKR/4
:12

:13
BUSR
:14

27

203

3406C & 3456 Generator Set


with EMCP II +
Electrical System

3406C

F27

201

SP4

BKRR/3

:9

205

NOTE:A

MOT2

MOT1

23

ETHER
START
SWITCH

-VE SUPPLY

29

REF.
CCC

BREAKER
CLOSED
LAMP

BREAKER
OPEN
LAMP

31

BKRR/1

:1

205

99

19

146

220

:3

MOT1

NOTE:
IF CONTROL PANEL IS SGCP THEN
SWITCH IS MOUNTED REMOTELY.

SECONDARY
120V AC L-L

Q/2

BREAKER
AUXILIARY

:30

31

26

NOTE
PT PRIMARY WIRE COLOURS
- WHITE
= 240V AC
- GREEN
= 380V AC
- BROWN
= 480V AC
- RED
= 600V AC
- BLACK
= COMMON

26

30

412

BLACK/WHITE

:13

REF.
AAA

BLACK

10

GREEN

30

ALARM
SILENCE

RED

BROWN

411

:4

SPEED
LOWER/RAISE
SWITCH

Q/1

232

:87

:1 MAN
:2 AUTO

16

:6

:C12

EPIR/1

28

SPARE

205

24V DC
SHUNT
TRIP

ST

ASOR+

B11

6A FUSE

10
8

B22
F37
(2A)

204

:C11

3456

58

B2

B21
F36
(2A)

:2

MOT1

ES-

B1

:5

4 POLE BREAKER OPTIONS

111

202

202

38

57

3456

SPARE

201

ABB ACB

:13
:14
:12
:2

L3

39

201

202

23

SPARE

:6

BREAKER
AUXILIARY

LINK

J1-1 J1-2 J1-3 J1-4


217
218
98

:5

L2

T3

REMOTE TERMS
FOR BREAKER
OPEN & CLOSED
POSITIONS

T2

24V DC
SHUNT
TRIP

ST

L1

:2
UVT
:10

99

90

L3

:C2

SPARE

:4

L2

T3

412

411

158

UV COIL SUPPLY
REFER TO BREAKER
DRAWING

T2

T1

27

SPARE

:3

CLOSE SIGNAL
REFER TO BREAKER
DRAWING

L1

ABB MCCB
107

~
SPARE

REMOTE TERMS
FOR BREAKER
OPEN & CLOSED
POSITIONS

ALR/2
:6

:3

:1

OPEN SIGNAL
REFER TO BREAKER
BREAKER DRAWING

:5

CR/2

(6A)

:8

GCR/1
:6

107

LINK

:4

T1

117

107

111

F31
(2A)

POWER SUPPLY
REFER TO BREAKER
DRAWING

REFER TO BREAKER DRAWING


N

POWER
WIRING FROM
GENERATOR

IF REQUIRED

157

117

117

POWER
WIRING TO
BREAKER

4 POLE BREAKER OPTIONAL


(SEE NOTE REF.A02)

DC POS.

IF 4 POLE BREAKER FITTED


CHANGE N
T0

DC NEG.

NOTE:

RENR8077-01
December 2006

GOVERNOR OPTION

EARTH FAULT RELAY OPTION


NEUTRAL EARTH LINK

AREP

T1
T1

T1

T2

TABLE: 1

T2

T3

T3

N1

T2
T3
N
E

N1

E
NOTE:

BT1

181
3

P
+

S
-

182

191

D
+

P
+

E
-

S
-

D
+

P
+

E
-

S
-

D
+

NOTE:
WIRE DIRECTLY ONTO
RELAY TERMINALS.

P
+

E
-

74

75
30

74
30

30

75

75

74
30

164

163
S
-

71

D
+

E
-

75

75

14

75

T3

L3

EF1

76
30

30

76

13

76

10

6
8

15

A1

CONNECT TO ALARM MODULE SPARE

33

14

22

21

CONNECT TO ALARM MODULE SPARE SHUTDOWN CHANNEL

12

24

11

`EFU'
A2
BENDER
EARTH FAULT RELAY

30

EF2

30

8
31

73

14

12

74

74

74

13

SP1
25

74

16

CONNECT TO ALARM MODULE SPARE


74

71

12

71

10

11

73

76

17

16

73

J3

60Hz

9/GREEN

10A FUSE

X1

X2

9/GREEN

PMG

15

X1

16

X1

UNDER SPEED ADJUST


P4

Z2

ST2

STABILITY ADJUST
P3

E+

R448

ST6

VOLTAGE ADJUST
P2

E-

110

NOTE:E

NOTE:F
POT
470ohm

3ph

AND R448

NOTE:C

380

T1
S1 S2

J1

BLACK

BLACK

RFI UNIT

P1
QUADRATURE DROOP ADJUST

ST4

OPTIONAL RFI KIT CONNECTIONS

ALTERNATOR
WINDING
CONNECTIONS

J2

. 7000 FRAME SIZE REQUIRES SPILT LINK - -

CONNECTION
TO EXCITER

NOTE:G

220

ST9

ST1

OR FOR 3 PHASE SENSING.

NOTE:D

BLACK
BLUE

ALTERNATOR
WINDING
CONNECTIONS

NOTE:B

- -

S1

14

X2

Z2

Z1

SP2

T1

1/2 PHASE
T1- T4 OR
T8 - T11

12/BLACK

EXCITATION CEILING ADJUST


P5

S2

71

SUPPLY STATOR PMG

10/YELLOW

P2

TI04

NOTE:H

P1

CONNECT TO ALARM MODULE SPARE


1

X2

11/RED

SP1
71

SUPPLY 140V MAX 50/60HZ

10/YELLOW

50Hz

60 HZ VOLTAGE WYE
480/277V - (T2 380)
440/254V - (T2 380)
380/220V - (T2 380)
240/139V - (T2 220)
220/127V - (T2 220)
208/120V - (T2 220)
600V
- (T2 220)

76

THERMOCOUPLE
RELAY

38

ST3

380)
380)
380)
220)
220)

NOTE:B
REMOVE LINK FOR REMOTE VOLTAGE ADJUSTMENT POTENTIOMETER
NOTE:C
REFERENCE TABLE 1 FOR CONNECTION BETWEEN ALTERNATOR (V)
NOTE:D
ST6 - 5000 AND 6000 ALTERNATOR FRAME SIZES FULL LINK NOTE:E
ST9 - AREP AND SHUNT - FULL LINK - . PMG SPLIT LINK NOTE:F
ST1 - FULL LINK. FOR 3 PHASE SENSING LINK MUST BE SPLIT
NOTE:G
FIT 5VA TRANSFORMER FOR 600V OPERATION
NOTE:H
OPTION TI04 FOR PARALLEL OPERATION.

CONNECT TO ALARM MODULE SPARE


75

L2

37

32

T2

30

30

L1

(T2
(T2
(T2
(T2
(T2

75
30

T1

NOTE:A
50/60 Hz SELECTION

24V

2
2

24V
-

192

164

172

4 POLE BREAKER OPTIONAL


(SEE NOTE REF.A01)

CORE BALANCE
CURRENT TRANSFORMER

WHITE

RED

WHITE

RED

WHITE

RED

RED

163
3

171

415/240V
400/230V
380/220V
220/127V
600V

IF 4 POLE BREAKER FITTED


CHANGE N TO

RTD
PT100

RTD
PT100

RTD
PT100

WHITE

RTD
PT100

NOTE:
WIRE DIRECTLY ONTO
RELAY TERMINALS.

TO
BREAKER
BOX

BT3

BT2

BT1

NOTE:A

50 HZ VOLTAGE WYE

CORE
BALANCE
C.T.

PMG

SHUNT

SUPPLY - AUXILLARY WINDING

DIAGRAM - WIRING (R448)

N
T7

T1
T4
T7
T10
T10
T12

T2

T4

T11

T5

T0

V
T2

T8

T5
T8

T0

T12

T6

T11

T9
T6

THERMOCOUPLE RELAY OPTIONS


W

T9

T3

SERIES STAR CONNECTION DIAGRAM

T3

AREP

PARALLEL STAR CONNECTION DIAGRAM

(HIGH VOLTAGE WYE)

NOTE:A
ST3

(LOW VOLTAGE WYE)

10/YELLOW

W (L3)
T12

T6

T9

T5

T8

LINK
T11

HEATER OPTIONS

T4

T11

T9

T5

T8

V (L2)
T2

T10

T1

T4

T7

CUSTOMER
LOAD
CONNECTIONS

JACKET WATER
JACKET WATER
BLOCK HEATER
BLOCK HEATER

HEATER IS
HEATER IS
IS FITTED
IS FITTED

FITTED FUSE F19


FITTED FUSE F19
FUSE F19 SHOULD
FUSE F19 SHOULD

COPPER BUSBAR

F16
(2A)

F17
(6A)
136

131

SHOULD BE 25A
SHOULD BE 16A
BE 15A
BE 10A
6 mm

F18
(4A)

F19
NOTE:A

6 mm

141

135

132

COPPER BUSBAR

45

CUSTOMER
100V TO 250V
AC SUPPLY
131

F16
(2A)

F17
(6A)

6 mm

46

134

136

131

6 mm

132

HEATER IS
HEATER IS
IS FITTED
IS FITTED

FITTED FUSE F19


FITTED FUSE F19
FUSE F19 SHOULD
FUSE F19 SHOULD

COPPER BUSBAR

45

CUSTOMER
100V TO 250V
AC SUPPLY
131

JACKET WATER
JACKET WATER
BLOCK HEATER
BLOCK HEATER

ST2

F16
(2A)

6 mm

F18
(4A)

F19
NOTE:A

6 mm

46

136

135

131

141

132

R448

ST6

VOLTAGE ADJUST
P2

110

3ph

NOTE:E

136

:4

:4

:4

CR/1
:1

CR/1
:1

CR/1
:1

J1

STATISME
P2

141

135

137

134

131

135

131

137

6 mm

2 .5 mm

P1
N

110

230

6 mm

NOTE:H

W
110

6 mm

TI04

BLUE

P2

ALTERNATOR
WINDING
CONNECTIONS

DIAGRAM - WIRING (R448 & R731)


400

230

400

6 mm

RFI UNIT

NOTE:I

V
110

230

2 .5 mm

134

141

BLACK

S1

R731

400

6 mm

S2

BLACK

S1

BLACK

S2

46

OPTIONAL RFI KIT CONNECTIONS

ALTERNATOR
WINDING
CONNECTIONS

131

TENSION
P1

137

4
45

CONNECTION
TO EXCITER

P1
QUADRATURE DROOP ADJUST

ST4

470ohm
POT

136

J2

NOTE: CUSTOMER CABLE TO


ENTER DIRECTLY ONTO
6 mm 2 TERMINALS.

136

NOTE:C

380

T1
S1 S2

134

NOTE: CUSTOMER CABLE TO


ENTER DIRECTLY ONTO
6 mm 2 TERMINALS.

220

ST9

POT
470ohm

NOTE:B

NOTE:G
NOTE: CUSTOMER CABLE TO
ENTER DIRECTLY ONTO
6 mm 2 TERMINALS.

E-

NOTE:D

CUSTOMER
100V TO 250V
AC SUPPLY
131

16

Z2

E+

SHOULD BE 25A
SHOULD BE 16A
BE 16A
BE 10A
2

PMG

15

X1

X1

NOTE:F
NOTE:A
IF 120V
IF 230V
IF 120V
IF 230V

14

X2

Z2

ST1
NOTE:A
IF 120V
IF 230V
IF 120V
IF 230V

9/GREEN

1/2 PHASE
T1- T4 OR
T8 - T11

12/BLACK

GENERATOR LEADS

10/YELLOW

Z1

STABILITY ADJUST
P3

T1

X1

X2

UNDER SPEED ADJUST


P4

U (L1)

X2

9/GREEN

10A FUSE

EXCITATION CEILING ADJUST


P5

T3

LINK

U (L1)

T7

T6
LINK

CUSTOMER
LOAD
CONNECTIONS

V (L2)
T2

LINK
T10

W (L3)
T12

T3

60Hz

SUPPLY STATOR PMG

SUPPLY 140V MAX 50/60HZ

11/RED

J3

50Hz

PMG

SHUNT

SUPPLY - AUXILLARY WINDING

4
3
134

141

137

:5

:3

HC
:2
131

140

- 3

FOR 5A CHARGER FIT (6A) FUSE


FOR 10A CHARGER FIT (10A) FUSE

140

131

131

131

+ 1

- 3

F15

36

(*)
2

FOR 5A CHARGER FIT (6A) FUSE


FOR 10A CHARGER FIT (10A) FUSE

134

141
:5

:3

:2
131

140

131

131

139
19

142
20

ALTERNATOR
HEATER

140

131

131

131

131

131

ENGINE
JACKET
WATER
HEATER

NOTE:A
50/60 Hz SELECTION
NOTE:B
REFERENCE TABLE 1 FOR CONNECTION BETWEEN ALTERNATOR (V) AND R448

:6

:4

:A2

CONSTANT
VOLTAGE CHARGER

6 mm

36

(*)

2 .5 mm

F15

131

ENGINE
JACKET
WATER
HEATER

ALTERNATOR
HEATER

131

:A1
HC

:A2

139
19

142
20

CONSTANT
VOLTAGE CHARGER
1

:6

:4

137

131

+ 1

135
:1

HC
:A2

24V DC
SUPPLY

131

:A1

:1

6 mm

135

131

:A1

2 .5 mm

137

2
1

NOTE:C
REFERENCE TABLE 2 FOR CONNECTION BETWEEN ALTERNATOR AND R731
NOTE:D
ST6 - 5000 AND 6000 ALTERNATOR FRAME SIZES FULL LINK - . 7000 FRAME SIZE REQUIRES SPILT LINK - - .
NOTE:E
ST9 - AREP AND SHUNT - FULL LINK - . PMG SPLIT LINK - - .
NOTE:F
ST1 - FULL LINK. FOR 3 PHASE SENSING LINK MUST BE SPLIT
.
NOTE:G
REMOVE FOR OPTIONAL VOLTAGE ADJUST POT.
NOTE:H
OPTION TI04 FOR PARALLEL OPERATION. WITHOUT 3 PHASE SENSING CONNECT TO S1 AND S2 ON R448 ONLY. STANDARD POSITION ON PHASE U.
FOR CT PARALLEL OPERATION ON PHASE V - MODIFY R731 VOLTAGE SENSING AS FOLLOWS - U(R731) -> V(ALT) . V(R731) -> W(ALT) . W(R731) -> U(ALT).
NOTE:I
FIT 2 x 5VA TRANSFORMERS FOR 600V OPERATION

TABLE: 1

TABLE: 2

50 HZ VOLTAGE WYE

50 HZ VOLTAGE WYE

415/240V
400/230V
380/220V
220/127V
600V

415/240V
400/230V
380/220V
220/127V
600V

(T2
(T2
(T2
(T2
(T2

380)
380)
380)
220)
220)

60 HZ VOLTAGE WYE
480/277V - (T2 380)
440/254V - (T2 380)
380/220V - (T2 380)
240/139V - (T2 220)
220/127V - (T2 220)
208/120V - (T2 220)
600V
- (T2 220)

(T1,T2&T3
(T1,T2&T3
(T1,T2&T3
(T1,T2&T3
(T1,T2&T3

380)
380)
380)
220)
220)

60 HZ VOLTAGE WYE
480/277V - (T1,T2&T3
440/254V - (T1,T2&T3
380/220V - (T1,T2&T3
240/139V - (T1,T2&T3
220/127V - (T1,T2&T3
208/120V - (T1,T2&T3

380)
380)
380)
220)
220)
220)

600V

- (T1,T2&T3 220)

30 Page

ALTERNATOR TERMINAL BOX

RENR8077-01 VOL 2

ALTERNATOR TERMINAL BOX

17

16

15
1

12

11

10

6 mm

2.5 mm

A+

SMMS1/1

PS1

PS2

SMMS2/1

25

SM1

T1

P1

P2

T2

S1
P1

S2
P2

CT1

T3

S1
P1

S2
P2

CT2

S1

S2

CT3

51

SM2

VOLTS ADJUST
POTENTIOMETER
(1K, 1 TURN)

SR/1
:87

PS2

SPEED ADJUST
POTENTIOMETER
(1K ,10 TURN)

ALT

B+

CHARGING
ALTERNATOR

:1

:3

80

:3

:1

12
11

12

13

34

14

35

26

36

10

44

43

FUEL INJECTOR
(128-8510)

CYL
NO.4

CYL
NO.3

CYL
NO.2

55

D-SPD

10

82

SIGNAL (-)
SIGNAL (+)

+5V
SIGNAL
RETURN

J23/P23
OR
A
GN
C
YL
B

+5V
SIGNAL
RETURN

N940/BU
A746/PK
N941/YL

J27/P27
OR
N940/BU
A
WH
A747/GY
C
BK
N941/YL
B

N940/BU
994/GY
N941/YL

67

53

15

50

LINK

LINK

T3

J1-5

H21
F12
(2A)

H22
F13
(2A)
T13

AC TRANSFORMER BOX
(ATB)

101

T12

T11
J1-1

101

110

110

109

109

108

108

27

RM
31

POST

5
48

17

61

15

99

12

14

63

90

43

SEE NOTE A

RM
33

RM
30

RM
35

35

F6
(10A)

RM
32

RM
1

RM
2

F3
(10A)

F1
(10A)

RM
8

FCR

CTR

RM
34

F4
(10A)

RM
6

RM
3

RR

SMR

CTR

RM
12

25

218
P

52

RM
36

RM
23

17

90

99
34

63

26

18

CCM+

CCM-

51

50

46

F5
(10A)

F7
(10A)

17
18
SPARE
SPARE

RM
5

RM
9

RM
7

SET OP6 SETPOINT SP17 TO 6


SET OP6 SETPOINT SP18 TO 7

ASR

D+

BODY

GPHI
RM
27

RM
15

RM
24

13

RM
13

RM
16

RM
17
39

RM
14
20

41

38

37

39

GPLO
RM
38
28
30

POST
B-

RM
18
14

RM
21

+
1

RM
39

26A

21

10

V-

11

23

24

PANEL
LIGHT
SWITCH

42

38

CCM-

22

21

37

38

11

:11

20

41

30

17

34

46

45

LOP
8

27

30 Page, B&W

BKUP SP/TMG SNSR


UNUSED
UNUSED
DIGITAL SNSR RETURN
ANALOG SNSR PWR (5V)
ANALOG SNSR RETURN
UNUSED
UNUSED
UNUSED
UNUSED
STARTING AID
UNUSED
GROUND LEVEL SHUTDOWN (NO)
GROUND LEVEL SHUTDOWN (NC)
UNUSED
DIGITAL SNSR POWER (+8V)
ENG. RTDR SEL. SW (LO/MED/HI)
UNUSED
ENG. RETARDER SEL. SW (HI)
UNUSED
UNUSED
ETHER START VALVE RELAY
UNUSED
UNUSED
BACKUP SPEED / TIMING SNSR (-)
UNUSED
UNUSED
UNUSED
ENG. RETARDER SEL. SW (MED)
UNUSED
+BAT. (UNSWITCHED)(NOTE B)
+BAT. (SWITCHED)
J1939 SHIELD
UNUSED
UNUSED
ATA DATA LINK ATA DATA LINK +
CAT DATA LINK CAT DATA LINK +
-BAT.

J1/P1
18
32
37
29
36
30
31
38
20
27
25
15
2
8
22
35
24
34
13
21
28
40
10
11
12
14
16
17
19
23
4
6
26
39
33
1
7
3
9
5

19

30
RDM

L983/WH
L984/OR
L985/YL
A706/GY
A705/BU
A704/GN
A703/BR
A702/PU
A701/GY
F723/PK
F724/PU

22

ASOR+

29

SD-PWR

D-

20
+

20

97

16

SD-RTN

10

:2

23

24

SP1
62

40

95

26

94

93

12

11

205
207

33

131
117
220
402
108

91

10
RM
22

34

37

37

157

5
36

37

35

110

159

J
K
L
M
N
O

R
S
T
U
V
W

202
203
205
207
131
117
220
402
108
110
157
159

8
9
10
11

7
6

14
15
3
5

16
17

10

16

67

15

25

SP2

SP3

41

40

39

29
SP4

42

40

55

42

33

56

32

57

39

41

66

54

55

34

56

58

44

37

36

49

59

60

22

SP1
16

62

53

61

SP2

62

17

SP3
18

63

:1

:2
:3
:4
:5

SP4
19

67

16

15

67

62

18

67

62

19

67

PANEL
LIGHTS

22

OFF/RESET
AUTO
START
COOLDOWN/STOP

CONTROL MODE
SWITCH

57

P1/2

62
16

37
7

19

18

30

37

30

30

57

38

9
8

ES-

EF1

59

EF2

4
3

N940/BU
N941/YL
F714/PK

52

SD-PWR

12

53

SD-RTN

D2

J3/P3
29

40
28

F704/OR
F702/GN

39

30

30

N944/PU
A745/WH
A746/PK
A747/GY
994/GY
A751/YL
C967/BU
E799/BR
F700/BU
F701/BR
995/BU

D+

41

:10
CR
:2

41
ASOR+

45

35

37

36

SD-PWR

51

10

SD-RTN

52

53

23A

12
6

11

47

41

46

41

15

65

10

16

30

30

20

25

17
48

34

45

49

45A

17

18

46
50

ES-

10
7

27

28

21

59
59

31

22
32

33

62T

67T

42

43

45A
21

NOT
CONNECTED

412/BU

16

15
14

13

NOT CONNECTED

22

67P

62P

18

67L

62L

44

45

20

21

19

18

67L

62L

19
23

19

67O

67O

EF2

D-

D+

61

62

EF1

EF2

EF1

62O

24

22

62O

J3/P3
10

S-SPD

12

E966/YL
F725/WH

DIAGRAM-WIRING
(EMCP II+)

D-SPD

21

998/BR
997/OR
993/BR
F703/GY
F718/BU
F706/PU
F720/GN
N942/OR
F715/PU
F716/WH
F707/WH
A700/OR
F719/BR
F709/BU
F722/OR
F705/PK
F708/YL
F710/BR

32

40

ATA-

31

451/BR
E965/BU
F717/YL

39

ATA+

450/YL
F721/GY
N943/BR
102/RD
150/OR
A234/BK
F712/GY
F711/GN
E793/BU
E794/YL
892/BR
893/GN
229/BK

AP-

19

AP+

12

11

46

10

34

10

23A

XT

DIAGRAM-WIRING
(ENGINE SCHEMATIC)

56

32

24

D+

D-

EMER.
STOP
ON
ENCLOSURE

ATAFP
ATA+

30

22
64
23

29

AP-

AP+

78

80

234-3205

82

72

59

145-3850

ATA-

ATA+

EF2

REF
B3

P+
65

82

ST4
R448
AVR

MAGNETIC
PICK UP No.1

:86
SR
:85

AIR SHUT-OFF
SOLENOID
ASOS

FP

SMMS1

B
CDVR

OIL
TEMPERATURE

REF
A11

CORE BALANCE
CURRENT TRANSFORMER
IF REQUIRED

59

REF
B3

COOLANT
LOSS

SASV

LOW
FUEL
LEVEL
SWITCH

10
REF
B10

NOTE A: VOLTS ADJUST CONNECTION WHEN USING A R448 REGULATOR


NOTE B: VOLTS ADJUST CONNECTION WHEN USING A CDVR REGULATOR

SMMS2

IF REQUIRED

VOLUME 2
3456 WITH EMCP II+

FIT IF REQUIRED

30
2

16

15

14

13

12

11

DIAGRAM-WIRING
(ENGINE HARNESS)
EF1

2
B

55

54

20
P+

80

FIT IF REQUIRED

SERVICE
CONNECTOR

20

56

64

20

11

F703/GY

46

20

SCR
8

30

30

31
9

55

41

J3/P3

14

SEE NOTE B

ES54

15

235-0745

8
SEE NOTE A

38

30

17

203

92

11

23A

54

:3

ASOR+

25

96

202

D+

DATA LINK

10

GROUND STUD

28

23
24

3
2

21

RDM

22

19

LCL
13

22

21

10

25

CR/3

26A

HET
7

45

EMER.
STOP

V+

31

43

59

15

31

30
24

AUX. ALARMS/SHUTDOWNS
SWITCHED -VE

17

38

20

D-

50

INJECTOR COMMON 1 & 2


INJECTOR COMMON 3 & 4
INJECTOR COMMON 5 & 6
INJECTOR 6
INJECTOR 5
INJECTOR 4
INJECTOR 3
INJECTOR 2
INJECTOR 1
TDC PROBE +
TDC PROBE UNUSED
UNUSED
ANALOG SNSR POWER (+5V)
UNUSED
INLET AIR TEMP SNSR
+V ENG SP/TMG
COOLANT FLOW SW COMMON
PRIM. SP/TMG SNSR
FUEL PRESSURE SNSR
TURBO OUTLET PRESS.
ATMOSPHERIC PRESS. SNSR
ENG OIL PRESS. SNSR
FUEL TEMP SNSR
INLET AIR TEMPERATURE SNSR
SOLENOID COMMON
ENGINE RETARDER (MED/HI) SOL
ENGINE RETARDER (LO/HI) SOL
COOLANT TEMPERATURE SNSR
UNUSED
UNUSED
THROTTLE POSITON SNSR
UNUSED
UNUSED
UNUSED
COOLANT FLOW SW
UNUSED
UNUSED
UNUSED
UNUSED

D+
21

RM
19

MOT2

29
23

21

19

437

26

15

EGR

DOOR

MOT1

21

D-

LOW OIL PRESSURE


EMERGENCY STOP
HIGH WATER TEMPERATURE
ENGINE OVERSPEED
OVERCRANK
(SPARE 1)
LOW COOLANT LEVEL
HIGH OIL TEMPERATURE
(SPARE 2)
SPARE 3
FAULT SHUTDOWN
FAULT ALARM

ENG OIL PR SNSR


(161-9926)

FUEL PRESSURE SNSR


(194-6725)

84

20

32

31

RDM

GENERATOR SET CONTROL (GSC)

GFR

58

29

19

RR

F10
(10A)

CHASSIS

57

81

15

D-

47

426

CCM+

36
SPARE

35
ALARM

KW

45

416

SMR

ATMOSPHERIC PRESS.
(161-9926)

FUEL TEMP SNSR


(102-2240)

MOT2

76

14

13

217

18

FCR

TURBO OUTLET PRESS.


(194_6724)

REF.
L07

MOT1

18

75

13

20

13

J3/P3

J2/P2
5
17
27
34
28
22
18
12
6
39
4
10
40
36
30
2
1
29
37
14
23
20
8
3
9
7
13
19
15
26
24
31
25
38
11
16
21
32
33
35

28

84

33

74

12

:9

ECM

27

81

32

46

CCM DATALINK

ABBREVIATION
ALT
ALTERNATOR
CB
CIRCUIT BREAKER
DIG
DIGITAL
CIS
CUSTOMER IGNITION SWITCH
ECM
ELECTRONIC CONTROL MODULE
NC
NO CONNECTION
PWM
PULSE WIDTH MODULATION
SM
STARTING MOTOR
SMMS
START MOTOR MAG SWITCH

16

76

:2
KWR
:10

RM
4

+5V
SIGNAL
RETURN

1. IF THE FAULT SHUTDOWN INDICATOR IS


FLASHING THEN THE LINK SHOULD BE
TEMPORARILY FITTED.
THE GSC SETPOINTS
MUST BE PROGRAMMED IN OFF/RESET WHEN
A FAULT SHUTDOWN IS ACTIVE.
IF THE
FAULT ALARM INDICATOR IS FLASHING THE
GSC CAN BE PROGRAMMED WITH THE CONTROL
SWITCH IN ANY POSITION.

LINK

T2

61

P47/J47
COOLANT FLOW SWITCH
412/BU
1
(NOT USED)
N944/PU
2

REF.
G14

COOL. TEMP SNSR


(102-2240)

+5V
SIGNAL
RETURN

J49/P49
OR
A
N940/BU
GN
C
A745/WH
YL
B
N941/YL

101

H23
F11
(2A)

F2
(10A)

+5V
SIGNAL
RETURN

P43/J43
OR
N940/BU
A
WH
A751/YL
C
BK
N941/YL
B

T3

22

BKUP SP/TMG SNSR


(4P-7610)

+5V
SIGNAL
RETURN

J22/P22
OR
A
GN
C
YL
B

52

PRIM. SP/TMG SNSR


(4P-7610)

SIGNAL (-)
SIGNAL (+)

P21/J21
OR
N940/BU
A
WH
995/BU
C
BK
N941/YL
B

T2

75

25

73

11

D+

P2/2

470 ohm
POT
ST4

B+

P44/J44
BK
E965/BU
1
WH
E966/YL
2

T1

T1

CONTROL
MODE SWITCH

AVR

P20/J20
BK
F724/PU
1
WH
F723/PK
2

50

50

:8
:9
:10

AUTO
START
COOLDOWN/STOP

30

32

30 31

INLET AIR TEMP SNSR


(107-8618)

74

31

72

OFF/RESET
80

R448

+5V
SIGNAL
RETURN

73

17

10

57

56

+B -B

P89/J89
OR
N940/BU
A
WH
C967/BU
C
BK
N941/YL
B

72

71

:6

CYL
NO.1

RETARDER SOLENOIDS
NOT USED

P26/J26
1
F723/PK
2
F724/PU

50

J1-2

91

82

SPEED CONTROL

S-SPD

CYL
NO.5

80

42

CYL
NO.6

53

J1-6

J1-3

92

51

J1-4

93

92

33

94

93

J1-7

95

91

P91/J91
12
D789/WH
10
D790/OR
D791/YL
8
A706/GY
6
A705/BU
5
A704/GN
4
A703/BR
3
A702/PU
2
A701/GY
1
D786/BR
11
D787/GN
9
7
D788/BK

52

J1-8

96

95

16

97

96

82

98

97

:2

94

RENR8077-01 VOL 2

11

6 mm 2

F723/PK
F724/PU

L3

14

IF REQUIRED

10

71

26

PS1

L2

40

KEY
REMOVABLE

L983/WH
L984/OR
L985/YL
A706/GY
A705/BU
A704/GN
A703/BR
A702/PU
A701/GY
F700/BU
F701/BR
E799/BR

L1

:2

13

:30

BATTERY
ISOLATOR
SWITCH

12

CB2
(60A)

CB3
(15A)

(OPTIONAL)

2.5 mm

CB1
(20A)
24

METERING C.T.S
1

24V

4 POLE BREAKER OPTIONAL

6 mm

2.5 mm

13

14

10