2. FILTER - convert pulsating to unidirectional forms 3. HOOK-ON WATTMETER measure w/t of electrical machines 4. DIMMER reduce brightness of incandescent lamps 5. SOFTWARE made calculation easier 6. FH-TRANSFORMER classified according to cooling system except. (FOA FDW OA) 7. SUPERPOSITION METHOD used with ckt with 2 or more voltage sources 8. 4 number of layers for 13.8 Kv 9. MCS latest trend in control of powerplant (SCADA REMOTE DIGITAL) 10. DISCONNECT SWITCH MANNER it breaks the circuit except top 11. Letters designated to cooling of transformers (O,L,G) except X 12. IEC standard for coolant circulation of transfoemers (N F D) except A 13. OIL CONSERVATION purpose of conservator tank of transformers 14. BIL factory test on transformers 15. CTs classification according to construction (wound primary, through a bar, window or bushing) except auxiliary 16. Cores of current transformers classified to metering and PROTECTION 17. Connection of CT when using differential relay for delta-wye. WYE-DELTA 18. LAOAG ILOCOS NORTE area most frequented by thunderstorm 19. FIELD HV electrical testing for machines are generally classified except(factory, proof , maintenance) 20. WHEATSTONE BRIDGE used to measure winding resistance of power transformers 21. TWO POINT simplest method for measuring ground resistance 22. HFERMI measure earth resistance 23. SR51 famous multi-amp relay test 24. DPWH-96-006E form for final electrical inspection 25. 12.4 kv/ft voltage gradiant of lighting at half mile horizontal distance 26. GROUNDING MECHANISM 0 used to discharge static charges on HV 27. JUNGUER other name for nickel cadmium battery 28. FORWARD BREAK OVER voltage applied to SCRs which switches to conduct w/o bias 29. 10 YEARS frequency of checking undercover power transformers 30. BURNISHER clean silver coaled contacts of relays 31. Anthracite coal w/ 90-95% carbon buns w/ no smoke 32. BALATA elastic grum from Venezuela used for insulation 33. BANJO in pole line construction for tightening a wire 34. BARAD unit of pressure in cgs 35. BELT CIRCUIT circuit for electric lighting connected in series with extended loop rather than parallel lines 36. BURETITIZE method of protection wood poles from decay by saturating it with zinc chloride 37. CONSNEQUENT poles occurring in a dyanamo oat points else where other than at pole pieces 38. CONVOLUTIONS loops in a coil of wire 39. CYRNOSCOPE device which indicates the presence of electric waves 40. ELECTREPETER used to change direction of electric currend 41. ENDOSCOPE lamp used to illimunate internal cautig of human body 42. ENTREFER open space ebetween the face of the pole piece of a dynamo and the surface of the armature 43. EPSTEIN HYSTERESIS TESTER use to measure hysteresis and eddy current losses in conjunction with an AC wattmeter 44. Zwitter ions ions which are positive and negative charge at the same time 45. KAPLAN reactor type turbine with adjustable blades suitable for run off rivers with variable head and flow 46. .285 SG of fully charged lead acid battery at 80F 47. CHORRITTEN common commercial name of synthetic insulation oil except this (chlorextor,inerten , ppyranol) 48. CO2 extinguishing agent for fires due to electrical
49. 140% - setting for overload protection of hermetic motors
50. 3R NEMA code for enclosures that are weather proof 51. 50A lowest ampere frame available for modelled case of CB 52. PLATINUM IRON common thermocouples used with potentiometer except this(iron-constantan, copper constantan, pronel-alumel) 53. 105C thermal limit of class A 54. DISSIPATION FACTOR R/X 55. PILOT small transformer set at any point in an AC system to indicate to the central station the pressure at that point 56. TRANSFORMER ON THE POLE most common outdoor type Mpe electric substation 57. LITZENDRANT multi stranded wire0having transpositions to reduce skin effect 58. FLUVIOGRAPH records automatically the water level on river or dam 59. CLYCLOMETER register number of rev made by motors or alternatios 60. 20% - spare breakers installed on panel board 61. RED COLOR code for the three phase hot conductor 62. N- used to purge sealed type power transformer 63. ELECTRIC POWER SUBSTATION can be classified except grounding (function, service control) 64. SHADED POLE can be reversed by physically inverting the position of the rotor 65. ENGLAND Michael faraday 66. ELECTRICAL MEASURING INSTRUMENT except electrodynamics 67. Residential,commercial,VA 200VA 68. GPR ground potential rise 69. Bedrock soil 10,000 70. CAPACITORS, IMPROVED PF- shunt 71. INDUCTION MOTORS , D, K lesser 72. CHARGING OF SECONDARY BATTERY trickle charging 73. Voltage regulation, determination except ANSI METHOD 74. Switching equipment separate, ISOLATED PHASE 75. Electrolyte , nickel iron POTASSIUM HYDRIDE 76. Parallel synchronous gen NONE OF THE ABOVE 77. Union skin 50% OF THE CONTACT AREA 78. Regreasing 50 to 100 HP ONCE EVER 4 MOS. 79. Alter voltage in DC MG SET 80. AC superior to DC FLEXIBILITY IN CHANGING VOLTAGE 81. Error , annalog measuring PARALLAX 82. Voltmeter, upper element defective 9,7 83. Motion electrical current speed CREEPING 84. Both positive and negative POSITION 85. R, cube, diagonal opposite 5/6 R 86. Ammeter, switches ,part ,, panel board copper third 87. DC system , transit trains 750 volts 88. DC system powerplants and substations 125 volts 89. Mix acid to water , electrolyte MIX ACID TO WATER 90. Asymmetrical, symmetrical X1.73 91. Windows 1000mm 92. SLD frontage of switch 0 miniature bus 93. Arrangement, free parallax semi- circular type 94. Modern road makers DELIMEATORS 95. Reduction capacity delta-delta 42.2% 96. Fasten, tray supports RAM set 97. Protect transformers, pressure bucholz relay 98. De-ion contact developed by WESTINGHOUSE 99. Sealed type transformer , purge NITROGEN 100. Polarity , transformer, additive , subtractive INDUCTIVE KICK 101. HV transmission line , safer PEOPLE WILL STAY AWAY 102. Sag except EARTHQUAKE 103. ACSR 266,000 18/1 WAXWING
Ratio of actual light COEFFICIENT OF UTILIZATION Hysteresis loss , reduced USING GRADIENT SILICON STEEL No-load current , magnetic flux EXCITING Windind, SM, start,rated , speed, - AMORTISSEU Latest CLASS E Sizes, ANSI/NEMA bigger T and pi combination 0 stenmentz equivalent ckt. Overload series fault Least prevalent LLL fault Rule of thumb 1000A/in^2 Only + and sequence LL fault Swinging panel, avoid parallax syndroscope Spot testing 1 minute PI, class B 1.5 % fill of conduits , NEC- <40%