1. General
1.1 General conditions of the ship
The following conditions are to be met, as far as praticable :
Inclining tanks are to be wall-sided and free of large stringers or other internal
members that create air pockets
tanks are to be directly opposite to maintain ship"s trim
Specific gravity of ballast water is to be measured and recorded
Pipelines to inclining tanks are to be full. If the ship"s piping layout is unsuitable
for internal transfer, portable pumps and pipes/hoses may be used
Blanks must be inserted in transverse manifolds to prevent the possibility of
liquids being "leaked" during transfer. Continuous valve control must be
maintained during the test
All inclining tanks must be manually sounded before and after each shift
Vertical, longitudinal and transverse centres are to be calculated for each
movement
Accurate sounding/ullage tables are to be provided. The ship"s initial heel angle is
to be established prior to the incline in order to produce accurate values for
volumes and transverse and vertical centres of gravity for the inclining tanks at
every angle of heel. The draught marks amidships (port and starboard) are to be
used when establishing the initial heel angle
Verification of the quantity shifted may be achieved by a flowmeter or similar
device
The time to conduct the inclining is to be evaluated. If time requirements for
transfer of liquids are considered too long, water may be unacceptable because of
the possibility of wind shifts over long periods of time.
1.4 Pendulums
The use of three pendulums is recommended but a minimum of two are to be
used to allow identification of bad readings at any one pendulum station. However,
for ships of a length equal to or less than 30 m, only one pendulum can be accepted.
They are each to be located in an area protected from the wind. The pendulums are to
be long enough to give a measured deflection, to each side of upright, of at least 10
cm. To ensure recordings from individual instruments are kept separate, it is
suggested that the pendulums be physically located as far apart as practical.The use of
an inclinometer or U-tube is to be considered in each separate case. It is
recommended that inclinometers or other measuring devices only be used in
conjunction with at least one pendulum.
Draught mark readings are to be taken at aft, midship and forward, at starboard
and port sides
The mean draught (average of port and starboard reading) is to be calculated for
each of the locations where draught readings are taken and plotted on the ship"s
lines drawing or outboard profile to ensure that all readings are consistent and
together define the correct waterline. The resulting plot is to yield either a straight
line or a waterline which is either hogged or sagged. If inconsistent readings are
obtained, the freeboards/draughts are to be retaken
The specific gravity of the sea water is to be determined. Samples are to be taken
from a sufficient depth of the water to ensure a true representation of the sea water
and not merely surface water, which could contain fresh water from run off of
rain. A hydrometer is to be placed in a water sample and the specific gravity read
and recorded. For large ships, it is recommended that samples of the sea water be
taken forward, midship and aft, and the readings averaged. For small ships, one
sample taken from midship is sufficient. The temperature of the water is to be
taken and the measured specific gravity corrected for deviation from the standard,
if necessary. A correction to water specific gravity is not necessary if the specific
gravity is determined at the inclining experiment site. Correction is necessary if
specific gravity is measured when the sample temperature differs from the
temperature at the time of the inclining (e.g., if the check of specific gravity is
performed at the office). Where the value of the average calculated specific
gravity is different from that reported in the hydrostatic curves, adequate
corrections are to be made to the displacement curve
All double bottoms, as well as all tanks and compartments which can contain
liquids, are to be checked, paying particular attention to air pockets which may
accumulate due to the ship"s trim and the position of air pipes, and also taking
into account the provisions of [1.1.1]
It is to be checked that the bilge is dry, and an evaluation of the liquids which
cannot be pumped, remaining in the pipes, boilers, condenser, etc., is to becarried
out
The entire ship is to be surveyed in order to identify all items which need to be
added, removed or relocated to bring the ship to the lightship condition. Each item
is to be clearly identified by weight and location of the centre of gravity
The possible solid permanent ballast is to be clearly identified and listed in the
report.
movements of personnel are allowed. For ships with a length equal to or less than 30
m, six distinct weight movements may be accepted.
Initial Position
1
4
1. Shift
1
2
3. Shift
4. Shift
3
4
5. Shift
2. Shift
3
4
6. Shift
7. Shift
8. Shift
2
3
4
2
3
2
4
7
8
4
2
Heeling angles tangent (port)