You are on page 1of 8

CIDCO OF MAHARASHTRA LIMITED.

Sl.Pg.No.

C.A.NO. 08/CIDCO/RP/SE(TP-III&HQ)/EE(BPR-I)/2010-11

CHECKLIST FOR READY MIX CONCRETE


SUPPLY OF CONCRETE (RMC)
Name of Work :
C.A.No. :
Name of Contractor/Client :
Sr.
Description
No.

Detail Information

1.

Name of RMC manufacturer with plant


address & telephone nos.

2.

Name of Plant In Charge


qualification & Experience

3.

Date of commissioning of RMC plant

4.

RMC Plant details

a)

Capacity of plant Design

with

Actual Output
b)

Whether plant fully automatic/Semi


automatic

c)

Conveyor belt for loading aggregate

d)

Aggregate
bin
with
various
compartments for different aggregate

e)

Mixer type

f)

No. of Transit Mixers with capacity

g)

No. of pumps

h)

No. of placer boom

i)

i) Separate silos with capacity for


Cement
ii) Fly ash

j)

Water storage arrangement

450

CIDCO OF MAHARASHTRA LIMITED.

Sl.Pg.No.

C.A.NO. 08/CIDCO/RP/SE(TP-III&HQ)/EE(BPR-I)/2010-11

Sr.
Description
No.
k) Plasticizer arrangement
l)

Arrangement
supply

for

alternate

Detail Information

power

m)

Arrangement for maintenance of P &


M.

n)

Storage capacity for raw materials

o)

Arrangement for curing tank


frequency of changing water

p)

Calibration frequency of plant with


traceability

q)

Whether
you
observe
the
accuracy/sensitivity
of
measuring
equipments within the limits of IS
4926:2003

r)

Details of Calibration frequency of


various testing equipments with
traceability & its record

5.

Quantity of RMC manufactured daily


M20
M25
M30
M35

6.

Source of materials
Cement-whether bulk supply
Coarse aggregate
Fine aggregate Sand
Crushed Sand
Water

&

451

CIDCO OF MAHARASHTRA LIMITED.

Sl.Pg.No.

C.A.NO. 08/CIDCO/RP/SE(TP-III&HQ)/EE(BPR-I)/2010-11

Sr.
Description
No.

Detail Information

Chemical Admixture
Mineral Admixture (Fly ash)
7.

Details of quality control testing &


records
of
various
constituents
materials

A)

Cement (IS 8112, IS 12269)


Whether MTC
(weekwise) available
Fineness
Soundness
IST & FST
Consistency
Compressive strength of
mortar cubes-no. of cubes

cement

Chemical tests
Physical & chemical testing at external
lab. & its frequency
B)

Coarse Aggregate (IS 383 : 1970)


Gradation
Specific gravity
Flakiness & elongation Index
Impact value/Crushing value/ Abrasion
value
Soundness
Alkali Aggregate reactivity test

452

CIDCO OF MAHARASHTRA LIMITED.

Sl.Pg.No.

C.A.NO. 08/CIDCO/RP/SE(TP-III&HQ)/EE(BPR-I)/2010-11

Sr.
Description
No.
C)

Fine aggregates (IS 383 : 1970)


Specific gravity
Determination of clay, fine silts, & fines
dust
Free moisture content
Soundness
Water absorption
Organic impurities

D)

Admixture (IS 9103 : 1999)


Whether MTC is available for every
batch & brand
Dry Material content
pH value
Relative Density
Compatibility
Ash content
Chloride ion content
Performance test for slump retention &
compressive strength test at 24hr. on
control mix.
Periodical testing at external lab. For
crosscheck

E)

Fly ash
(IS 3812 : 2003)

Detail Information

453

CIDCO OF MAHARASHTRA LIMITED.

Sl.Pg.No.

C.A.NO. 08/CIDCO/RP/SE(TP-III&HQ)/EE(BPR-I)/2010-11

Sr.
Description
No.
Whether MTC available
Physical properties
1. Specific surface
2. Residue on 45 micron IS sieve
3. Lime reactivity
4. Comp. Strength
5. Soundness
Chemical properties chemical Analysis
Periodical testing at external lab. For
crosscheck
F)

Water (IS 456 : 2000, IS 3025 : 1964)


pH value
Sulphates
Chlorides
Organic matter
Suspended matter
Periodical testing at external lab. For
crosscheck

G)

Concrete (RMC)

a)

Mix Design & Trial Mixes


Method of design
(whether as per IS or any other)
b. Whether it is as per requirement of
client or your own

b)

Daily check on preparation of starting


slips for each of grades based on

Detail Information

454

CIDCO OF MAHARASHTRA LIMITED.

Sl.Pg.No.

C.A.NO. 08/CIDCO/RP/SE(TP-III&HQ)/EE(BPR-I)/2010-11

Sr.
Description
No.
adjustments of moisture content or
water absorption (at 7,11,15,19 hr.) as
per schedule
c)

Analysis of fresh concrete Mix as per IS


1199 1959.

d)

Temperature of the fresh Concrete Mix

e)

Slump at the Plant

f)

Check for Density for each grade

g)

Cube Comprehensive Strength


Acceptability Records of tests

h)

Permeability apparatus

i)

NDT equipments & co-relation with


cube compressive strength

j)

Cement content test

k)

Chemical analysis of concrete samples

l)

Statistical analysis of test results &


modification to the mix proportion
based on standard deviation of plant

m)

&

Special Precautions taken


a. During Rainy season
b. During Hot season

8.

Technical staff available at plant with


qualification & experience

9.

Technical Staff to accompany transit


mixer with qualification & experience

10.

Time of availability of RMC supply

11.

Delivery tickets as per Annex G (Cl.9.4)


of IS 4926-2003
(Alongwith every load/transit mixer)

Detail Information

455

CIDCO OF MAHARASHTRA LIMITED.

Sl.Pg.No.

C.A.NO. 08/CIDCO/RP/SE(TP-III&HQ)/EE(BPR-I)/2010-11

Sr.
Description
No.
12.

Detail Information

Test frequency for all whether as per IS


4926-2003

13.

Any incidents of failure in quality


supplied

14.

Any incidents of failure in timely supply

15.

Details of works where RMC used


Major Clients

16.

Any other information

17.

Third Party Inspection Name of agency,


Frequency & Report.

18.

Monitoring of Ready mixed Concrete


as per IS 4926:2003

a)

If more than one admixture is used,


confirmation of their compatibility

b)

IST & FST of concrete when admixture


is used at adopted dosage (As per IS
8142)

c)

Time

of

transportation

(Shall

not

exceed 2 hours for normal case.)


d)

Frequency of Compressive strength


(One sample (3 specimens) for every
50 Cum or 50 batches whichever is
greater).

456

CIDCO OF MAHARASHTRA LIMITED.

Sl.Pg.No.

C.A.NO. 08/CIDCO/RP/SE(TP-III&HQ)/EE(BPR-I)/2010-11

Sr.
Description
No.
e)

Any

457

Detail Information

additional

compliance

criteria

shall be declared to the producer by


the purchaser prior to supply & shall
be mutually agreed upon.
f)

The action to be taken in case of noncompliance

shall

be

declared

&

mutually agreed upon.


Also enclosed herewith Annex I i.e. Material Testing requirements as per IS 4926 :
2003.

Signature of RMC Supplier


M/s.
Name
Checked by