You are on page 1of 1

SYS19: BASE4

50:

95:

98:

100:

JOB: GECON01--0057-1 Name: 1-57

STIBOINFO((GE:MAIN:CON:57))

DATE: NOV 15 2001

Time: 1:31:08 PM Operator: AJ COLOR: CMYK

TCP: 891

Typedriver Name: TS name

Rev

csm no.: 100

Contents

Zoom: 100

Fwd

GE NEMA Rated Full Voltage Starters

CR305X, CR385X Auxiliary Contact Kits for Field Installation


300-Line Auxiliary Contact Kits
on Magnetic Contactors and Starters
NEMA Sizes 0-7

starters; and, in conjunction with a standard reversing starter and


plugging switch, to plug-stop motors. Auxiliary contacts can be
added to all across-the-line magnetic starters and contactors,
combination magnetic starters, reversing and multi-speed
controllers.

NEMA FULL VOLTAGE


STARTERS

5:

2:

Each auxiliary contact is rated 10 Amperes ac, resistive load,


NEMA A600, and is suitable for either right or left side mounting.
An insulating shield is also provided between each auxiliary
contact unit and the starter. Auxiliary contacts are furnished in the
basic block design or as an adder block.
Each contact is marked NO or NC on the block and is not
convertible.
Basic block

Logic reed contacts suitable for low energy level circuits are also
available. These are designed for applications on low-voltage
control circuits (24 Volts and below), such as inputs to computers
and programmable controllers.

Adder block

Application

Auxiliary contacts can add to the versatility of magnetic contactors


and starters by providing additional control circuits to do a variety
of jobs without adding to the width of the starter.
Kits make it easy to add contacts to control accessory equipment
such as indicating lights; to control sequencing of other motor

Ordering Directions

Order by quantity and complete Catalog Number. Example: Three


CR305X300A at $36.00 each, GO-10G.

Auxiliary Contact Kits for 300-Line Size 0-6 Contactors and Starters
NEMA Size
Contactor
or Starter

(Also suitable for 200-Line)


Adder Blocks 1

Basic Blocks
1 NO-1 NC
Contacts

Catalog Number

List
Price,
GO-10G

0, 1
2

CR305X100A
CR305X200A

CR305X100B
CR305X200B

$ 36.00
36.00

CR305X100C
CR305X200C

$ 48.00
48.00

CR305X100D
CR305X100D

CR305X100E
CR305X100E

$36.00
36.00

3
4

CR305X300A
CR305X300A

CR305X300B
CR305X300B

36.00
36.00

CR305X300C
CR305X300C

48.00
48.00

CR305X100D
CR305X100D

CR305X100E
CR305X100E

36.00
36.00

5, 6

CR305X500A

CR305X500B

36.00

CR305X500C

48.00

CR305X100D

CR305X100E

36.00

1 NO Contact

1 NC Contact

Catalog Number

Catalog Number

List
Price,
GO-10G

Catalog Number

List
Price,
GO-10G

1 NO Contact

1 NC Contact

Catalog Number

Auxiliary Contact Kits for Size 7-9 Contactors and Starters


7

CR385X600A

CR385X600B

198.00

CR385X600C

396.00

CR305X100D

CR305X100E

36.00

8-9

CR385X800A

CR385X800B

198.00

CR385X800C

396.00

CR305X100D

CR305X100E

36.00

Note: Four extra auxiliary contacts (not blocks) is the maximum that can
be added to either a NEMA size 0 or 1 contactor/starter while five is
the maximum extra auxiliary contacts that can be added to NEMA
Size 2 through 6 devices.

Logic Reed Switch Auxiliary Contacts


Contact Arrangement
NO

NC

Catalog
Number

00, 0, 1

1
0
1

0
1
1

CR305X100RA
CR305X100RB
CR305X100RC

$45.00
45.00
72.00

1
0
1

0
1
1

CR305X200RA
CR305X200RB
CR305X200RC

45.00
45.00
72.00

3, 4

1
0
1

0
1
1

CR305X300RA
CR305X300RB
CR305X300RC

45.00
45.00
72.00

5, 6

1
0
1

0
1
1

CR305X500RA
CR305X500RB
CR305X500RC

45.00
45.00
72.00

NEMA Size

References:

List Price,
GO-10G

1 First adder block must be mounted to a basic block. A second adder


block can be added to the first adder block on size 2 through size 6
contactors and starters.

Note: CR305X logic reed switch auxiliary contacts may be


ordered as a factory-installed modification. Order by description.
For factory-installed modification, add $75.00, GO-10G, per
circuit to price of starter/contactor.

Contact Ratings

High Fidelity Contact Basic Block

120 Vac maximum .15 A maximum, 8 VA maximum resistive.


30 Vdc maximum .15 A maximum, 4.5 VA maximum resistive.
Standard Block
AC Volts

Continuous
Current
Amperes

Inrush
Current
Amperes

DC Volts

Continuous
Current
Amperes

Inrush
Current
Amperes

115
230
460
575

6.0
3.0
1.5
1.2

60
30
15
12

125
250

1.1
0.5

Instructions

NEMA Size

Publication Number

0, 1
2
3, 4
5, 6
7-9
0, 1 Logic Reed
2 Logic Reed
3, 4 Logic Reed
5, 6 Logic Reed

GEH-4758
GEH-4759
GEH-4760
GEH-4761
GEH-5109
GEH-5178
GEH-5185
GEH-5186
GEH-5187

Prices and data subject to change without notice

1999 Issue

1-57

MK

You might also like