You are on page 1of 1124

copyright 2012 maryland metrics/helukabel gmbh

CABLES & WIRES


2012/2013
HELUKABEL Products
are available from

MARYLAND METRICS
P.O. Box 261 Owings Mills, MD 21117 USA
ph: (410)358-3130 (800)638-1830
fx: (410)358-3142 (800)872-9329
email: sales@mdmetric.com web: http://mdmetric.com
RFQ form: http://mdmetric.com/rfq.htm

How to order: Please preface each HELUKABEL part number with R955K- Example (using the part number): R955K-14078

Also click here to access the Helukabel Cable Accessories catalog

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Welcome

Photo: HELUKABEL Headquarters Hemmingen

HELUKABEL are today one of Germanys leading cable companies, boasting an extensive range of cables,
wires, special cables, media technology, cable accessories, as well as Data, Network & Bus Technology and cable
protection systems for robotics and handling systems.
Today, we produce for all markets and for every purpose. Our extensive warehouse stock, containing over
33,000 articles, enables us to deliver your order within extremely short delivery times.
The catalogue provides a full overview of cables according to overseas standards, which is constantly being
expanded according to the markets requirements. The employees of our internal and eld sales teams are
happy to advise and assist you in nding the best solution for your needs.
You can reach us at:
HELUKABEL GmbH Headquarters
Dieselstr. 8-12 71282 Hemmingen Germany
Phone +49 7150 9209-0
Fax +49 7150 81786

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

List of contents
Type

Page

Prex
Table of Contents ...............................................................................................................................................................2 to 3
Our product ranges............................................................................................................................................................4 to 5
Research & development ..................................................................................................................................................6 to 7
The Production Windsbach/Nuremberg ................................................................................................................................... 8
The Logistic Centre .................................................................................................................................................................... 9
Mounting parts for cable protection systems ........................................................................................................................ 10
Pre-assembled cable protection systems for Robotics .......................................................................................................... 11
Kabelmat winding systems ....................................................................................................................................... 12 to 13
The way to HELUKABEL - Germany / worldwide ........................................................................................................... 14 to 15
Our registered trademarks ...................................................................................................................................................... 16
Achieving Success through Quality and Innovation................................................................................................................ 17
CCC-Zertication for China ..................................................................................................................
.............................. 18
Clean Room Qualied cables.................................................................................................................................................... 19
DESINA-Cables ............................................................................................................................................................... 20 to 21
British Standard ....................................................................................................................................
.............................. 22
Selection tables

23 to 42

Selection table exible control cables / halogen-free ................................................................................................. 24 to 26


Cables halogen-free ................................................................................................................................................................. 27
Cables for foreign standards ..................................................................................................
................... 28 to 29
Selection tables cables in Drag Chain ...............................................................................................
................... 30 to 35
Installation manual cable installation in drag chains ........................................................................
.............................. 36
Questionnaire for Energy Drag Chain Systems ...................................................................................
.............................. 37
Assembly instructions / laying reel cables NSHTU / (N)SHTU .................................................................................. 38 to 39
Selection table for low voltage joints ........................................................................................................................... 40 to 42
Industrial Cables & Wires

Flexible Control Cables ................................................................................................................................ A


Data and Computer Cables ......................................................................................................................... B
Cables for Drag Chains .........................................................................................................................
C
Motor, Servo & Feedback Cables ................................................................................................................ D
Heat-resistant Cables .................................................................................................................................. E
Allweather and Rubber Cables .................................................................................................................... F
Trailing Cables .............................................................................................................................................. G
Robot Cables ............................................................................................................................................... H
Water resistant Cables ................................................................................................................................. I
Flat and Ribbon Cables................................................................................................................................ J
Single Conductors ....................................................................................................................................... K
Compensating Cables ................................................................................................................................. L
Coaxial Cables .............................................................................................................................................. M
Cables according to International Approvals........................................................
N
Infrastructure Cables and Wires

Installation Cables ........................................................................................................................................ O


Telephone and Fire Warning Cables ........................................................................................................... P
Power Cables, Security Cables and Medium Voltage Cables ..................................................................... Q

1 to

N 157

1
1
1
1
1
1
1
1
1
1
1
1
1
1

A 96
B 34
C 36
D 26
E 20
F 14
G 10
H 10
I
8
J 10
K 44
L 12
M 12
N 157

to
to
to
to
to
to
to
to
to
to
to
to
to
to

1 to Q

63

1 to
1 to
1 to

O 10
P 12
Q 63

Data, Network and Bus Technology

1 to

R 163

Media Technology

1 to

31

Special Cables

1 to

55

Pre-assembled Cables

1 to

U 63

Spiral Cables

1 to

Shipwiring and Marine Cables

1 to

W 23

Technical Information

1 to

X 113

13

Glossary of Therms..................................................................................................................................... X 114 to X 125


Part Number Index..................................................................................................................................... X 126 to X 142
Enquiry Special Cables .....................................................................................................................................................T 55
Enquiry Spiral Cables ........................................................................................................................................................V 13
Fax Request .........................................................................................................................................................................X 147

1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Table of Contents
A 1 96

Flexible
Control Cables
B

1 34

Trailing Cables
H 1 10

Data and
Computer Cables
C

1 36

Robot Cables
I

Motor, Servo &


Feedback Cables
E

1 20

1 14

Allweather and
Rubber Cables

1 10

Flat and
Ribbon Cables
K

Heat-resistant
Cables
F

18

Water resistant
Cables

Cables for
Drag Chains
D 1 26

1 10

1 44

Single Conductors
L

1 12

Compensating
Cables

2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Table of Contents
M 1 12

Coaxial Cables
N 1 157

Media Technology
T

Cables according
to International
Approvals
O 1 10

1 12

Telephone and
Fire Warning
Cables
Q 1 63

Power Cables,
Security Cables
and Medium
Voltage Cables
R

1 163

Data, Network and


Bus Technology

1 55

Special Cables
U 1 63

Pre-assembled
Cables

Installation
Cables
P

1 31

1 13

Spiral Cables
W 1 23

Shipwiring and
Marine Cables
X 1 113

Technical
Information
3

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Our product ranges

CABLES & WIRES


HELUKABEL can deliver cables and wires
for any industrial application. Our extensive
warehouse stock, containing over 33,000
articles, enables us to deliver order within
extremely short delivery times.

2008
/200
9

You can nd more information about this


in our actually catalogue CABLES &
WIRES.

CABL
ES &

WIRES

www
.helu

kabe

l.de

SPECIAL CABLES
We supply cables and wires for both standard
applications and bespoke solutions to meet
customers individual and application-specic
requirements. Those cables can be designed,
constructed and produced in our own
factory, encluded cables for photovoltaic
and wind power.
Just give us a call our team will be
happy to advise you.

CABLE ACCESSORIES
As a signicant addition to the extensive
program of cables and wires, HELUKABEL
provides a cables accessories program
according to the latest guidelines and
standards. For example: Cable glands, cable
glands accessories, protective tubes, drag
and guidance chains.
More information and all products in
our catalogue CABLE ACCESSORIES.

4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

If you require additional copies of any catalogues


or brochures below, simply ll out the request
from provided at the back of this catalogue or at
the internet.

DATA, NETWORK & BUS TECHNOLOGY


HELUKABEL can offer an extensive range
of equipment for networking heterogenous
systems using bre optic and copper
techniques. HELUKABEL is able to meet
with its brands HELUCOM, HELUCOM
Connecting Systems, HELUKAT and
HELUKAT Connecting Systems all of your
cable and accessories you needs.
en

A, NE
TWOR
K & BU
S TECH
NOLO
GY 20

08/2

009

All products to nd in the catalogue


DATA, NETWORK & BUS TECHNOLOGY.
DATA
, NETW
BUS
TECH ORK &
NOLO
GY

www
.helu

kabe

l.de

 



MEDIA TECHNOLOGY
For years, our cables have ensured perfect
performances on Europes leading musical
and theatrical stages. They are also used
in professional television, radio and studio
equipment and at large-scale events such
as the football world championships.
Our product range for media equipment
encompasses cables for both indoor
and outdoor use. It guarantees
high transmission quality for xed
installations or for mobile use.

in Hemm

ingen

MED

IA TE
CH

NOLO

GY

More information in our new catalogue


MEDIA TECHNOLOGY.

www
.helu

kabe

l.de

ROBOTICS
HELUROBOTICS covers the complete
service spectrum, including system analysis,
consulting, planning, installation, service and
warranty, for mass-produced cable protection
systems for robots in automation systems.
Our specialists select with you the correct
cables, lines, supplemental systems and
cable protection systems to be used
with your specic application, conceive
and construct the suitable system, and,
with our partners, perform installation
and service on site.

5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Research & development

We devise optimised cable solutions


for our customers.

Photos: HELUKABEL

The focus is very much on products for


mobile use with a high level of vertical integration. Our customers expect extreme
resistance to chemical, electrical and
mechanical stresses combined with small
bending radii, a high number of exing
cycles and outstanding service lives we
are happy to comply.

6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Our design engineers rely on


the latest software to develop our
cables. This software makes the
cores' movement scenarios in the
cable sheath visible.

New products are tested in the state-of-the-art


Test Center in Windsbach/Nuremberg to ensure their suitability for daily use and readiness
for standard production. Our stringent quality
standard is also upheld with measurements
and random sample checks carried out during
production.

Once these prereqisites are


met, we can optimize the
products - according to the
type of stranding, lay-length
and material - and the corresponding manufacturing
technique.

In order to provide information on the service life,


we document the real-life
tests we carry out on our
cables suitable for use in
drag chains.

The effect of
changing the lay-length

7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

The Production Windsbach/Nuremberg


Here we are realizing standard cables,
special cables and customer-specic
special solutions.

The annual production of our own plant in Windsbach/Nuremberg, which has a production surface area over 10,000 m2 and
approx. 145 employees, this equates to approx. 50,000 km of
cable or 340,000 core kilometres.
The products include shielded, unshielded and steel wire
reinforced control cables with PVC/PUR sheath or thermoplastic
elastomers and halogen-free, ame-resistant and heat-resistant
shielded and unshielded cables. Our range is rounded off by
special-purpose cables produced to customer requirements.

8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

The Logistics Centre


A large part of the product assortment,
which has over 33,000 articles, is held
starting from the Hemmingen storage.

To meet the increasing demands of the market, HELUKABEL


opened a logistics centre. The goal of the logistics centre
is to increase the order to deliveryprocess through automation.
Innovative warehouse engineering and high-tech information
techniques make this installation unique in the cable business.
State of the Art automation allows hundreds of orders to be
lled daily. Our Just in Time system pulls product from over
16,000 pallet storage locations.

9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Mounting parts for cable protection systems

Components for mounting the dress


package systems

Photos: HELUKABEL

The pre-assembled cable protection systems for robotics also include the
manufacture and development of the metal components, for handling,
MAG and spot-welding, as series, individual or special solutions as well as
service and installation. HELUKABEL provides extensive warehouse stock
here for fast availability.
Simply call Phone (410)358-3130 (800)638-1830.
We will be happy to advise you.
Simply request further documentation
from our website http://mdmetric.com

10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled cable protection systems for Robotics

Our own pre-assembled cable protection systems


as tailored solution

Photos: HELUKABEL

With HELUROBOTICS, we offer specially assembled cable protection systems. From the planning, engineering and assembly to installation and
servicing, we offer a wide range of complex solutions as individual or
special solutions. The cables, wires, add-on systems and the cable
protection system that is used are then tuned to the application, built
and installed.
Simply call Phone (410)358-3130 (800)638-1830.
We will be happy to advise you.
Simply request further documentation from
our website http://mdmetric.com

11
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

The System Provider for


Winding, Measuring & Warehouse Systems

Kabelmat Wickeltechnik GmbHs history goes back to the sixties and for a
long time, the company has been among the market leaders for winding
systems for the cable and wire industry and/or processing. Customers
include manufacturers, retailers and processors of cables and wires as well as
tters, electrical installers, machine construction companies and many more.
The product portfolio includes almost all devices and machines for storage,
winding and hanging of cables and wires, steel cables, pipes, hoses and
proles. The tasks completed worldwide by Kabelmat products include
winding from and to drums, as well as from drums to rings.

12
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Manual winding systems

TROMTRAK 1250

These are Kabelmat winding devices and machines without


electromotive actuation. When it comes to winding systems,
Kabelmat differentiates between rewinding and unwinding.
Kabelmat offers different designs and sizes for rewinders
as well as unwinders, for drums and rings.

TISCHROL II

Measuring systems
Our length measuring devices are available in different
designs and sizes. The size depends on the maximum
diameter of the material to be measured. The MESSBOI 40,
for example, is qualied for measuring round material up to
a diameter of 40 mm. Flat materials can also be measured.
We currently have measuring devices for a maximum of 100
mm diameters in our program.

MESSBOI M40 Band

MESSBOI M30

MESSBOI M40/025 BAE

Machine winding systems


These are Kabelmat winding devices and machines with
electromotive actuation. Efcient, cost-effective cutting,
measuring and winding of cables and wires, steel cables,
pipes, hoses and proles requires high-performing but
easily operatable machines. Modern control systems and
drive technologies of well-known German suppliers are
used by Kabelmat in the eld.

Ringrol 300 / 400 / 500

MOTROL 1000 AUF

Warehouse systems
These are Kabelmat cable drum or cable ring storage and
unwinding systems. With its warehouse systems MATBOI,
SPULBOI, LAGBOI and LAGROL, Kabelmat offers to
organize your cable warehouse. In addition, the LAGROL
system provides the option to use a manual or machinedriven winder for direct unwinding.
SPULBOI

LAGBOI S

Become aquianted with our complete


winding, measuring & warehouse
product range. Just download our
catalogue via www.kabelmat.com

MATBOI 450 / 650

13
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contact Germany
Sales ofce
D-25524 Itzehoe
Bahnhofstrae 9
Telephone +49 4821 40394-0 Fax +49 4821 40394-29

Sales ofce and stock


D-15366 Neuenhagen/Berlin
Zum Mhlenie 1
Telephone +49 3342 2397-0 Fax +49 3342 80033

Sales ofce
D-47269 Duisburg
Am Handwerkshof 2-4
Telephone +49 203 73995-0 Fax +49 203 73995-210

Sales ofce and stock


D-09212 Limbach/Oberfrohna
Eichelbergstrae 7
Telephone +49 3722 6086-0 Fax +49 3722 6086-420

Development & production


D-91575 Windsbach/Nuremberg
Neuseser Weg 11
Telephone +49 9871 6793-0 Fax +49 9871 1055

Headquarters
D-71282 Hemmingen
Dieselstrae 8-12
Telephone +49 7150 9209-0
Fax +49 7150 81786

14
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contact International

Branch
Exclusivagent

How to nd our export department: Ph. +49 7150 9209-337 Fax +49 7150 81786

HELUKABEL AG (CH)
Grabckerstrasse 60 CH - 8957 Spreitenbach
Ph. +41 56 4181515 Fax +41 56 4181516
info@helukabel.ch

HELUKABEL CZ s.r.o. (CZ)


Arel dolu MAX CZ - 27306 Libun/Kladno
Ph. +42 0312 672620 Fax +42 0312 672621
info@helukabel.cz

Bro Suisse Romande (CH)


Ph. +41 24 4414414 Fax + 41 24 4414412

HELUKABEL Russia (RU)


St. Petersburg
Ph. +7 981 7691474
info@helukabel.ru

HELUKABEL ITALIA S.R.L. (IT)


Via delle Rovedine, 23 I - 23899 Robbiate (LC)
Ph. +39 039 9515450 Fax +39 039 9281579
info@helukabel.it
HELUKABEL Polska Sp.z o.o. (PL)
Krze Duze 2 PL - 96325 Radziejowice
Ph. +48 46 8580100 Fax + 48 46 8580117
info@helukabel.pl
HELUKABEL B.V. (NL)
De Kempen 4 NL - 6021 PZ Budel/Eindhoven
Ph. +31 495 499049 Fax +31 495 499048
info@helukabel.nl
HELUKABEL France SARL (FR)
3, rue DMC-B.P. 30 Z.A. du Pont dAspach
F - 68520 Burnhaupt le haut
Ph. +33 389 627562 Fax +33 389 627700
info@helukabel.fr
HELUKABEL BELGIUM BVBA (BE)
Z.1 Researchpark 310 B - 1731 ZELLIK
Ph. +32 24 810020 Fax +32 24 810022
info@helukabel.be

HELUKABEL Kablo San. ve Tic. Ltd. Sti (TR)


Siyavuspasa Cad. Cevizlik Sok. Birlik Ap. 19/1
TR - 34182 Bahcelievler/Istanbul
Ph. +90 212 5024195 Fax +90 212 5024198
info@helukabel.com.tr
HELUKABEL USA, Inc. (US)
1355 Bowes Rd, Unit C USA - Elgin, IL 60123
Ph. +1 847 9305118 Fax + 1 847 6228766
HELUKABEL South Africa (PTy) Ltd.
18, Staal Street
ZA - Kya Sand / South Africa
Ph. +27 11 462 8752 Fax +27 11 462 8638
doug.gunnewegh@helukabel.co.za
HELUKABEL Intl Trading
(Shanghai) Co., Ltd. (CN)
1st Floor, Bldg No. 4, 668 HengAn Rd.,
Pudong
New Dist. Shanghai
PRC - 200137 Shanghai
Ph. +86 21 58693999 Fax +86 21 58693666
info@helukabel.com.cn

HELUKABEL Singapore Pte. Ltd. (SG)


No. 3, New Industrial Road #01-01
Kimly Building SGP - Singapur 536197
Ph. +65 64 880170 Fax +65 62 851513
info@helukabel.sg
HELUKABEL KOREA Co., Ltd. (KR)
521-17 Daejeo 2 Dong Gang-seo Gu
ROK - Busan Korea
Ph. +82 51 9728646 Fax +82 51 9728649
info@helukabel.co.kr
HELUKABEL (Thailand) Co. Ltd (TH)
73/4 Moo.1 Bangkruay-Sainoi Rd.
Banglane, Bangyai T - 11140 Nonthaburi
Ph. +66 2927 35703 Fax +66 2927 35745
info@helukabel.co.th
HELUKABEL INDIA PVT. LTD. (IN)
F-305 Kailash Complex, Hiranandani Gardens
Link Road, Vikhroli West
IND - Mumbai 400 079
Ph. +91 22 25185841 Fax +91 22 25185839
info@helukabel.in
HELUKABEL MALAYSIA SDN BHD
No. 11-1 & 11-2, Jalan PJU 3/38
Sunway Damansara Technology Park
MY - Petaling Jaya, Selangor
Ph. +603 7885 8724 Fax +603 7885 7825
sales@helukabel.com.my

HELUKABEL AB (SE)
Spjutvgen 1 S - 175 61 Jrflla
Ph. +46 8 7617805 Fax +46 8 6210059
info@helukabel.se

15
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Our registered trademarks


de ar
rk
k
CABLES AND WIRES
BIOFLEX-500

Bio-Oil
o Oil res
o-Oil
resistant
resis
stant C
Cables
able
es

DATAFLAMM

Data
ata and
nd Comput
Computer
Co
omput
ompu
m ter Cables halogen-free
allogen-f
ogen fr

DATAPUR-C

Data
a a and
nd C
Computer
Co
Computer Cables
ables
bles

GALVANICABLE

High-current
i
current
rrent ccat
cathode
hod
de C
Cables

Heat
e t resistant Cables
Cabl
Cabless

HELUFLON

HELUTHERM

Heat
eat resistant Cables
Cabl
Cab es

HELUTRAIN

Train
n Cab
C
Cables

Vehicle
cle Cabless / Truck
ruck
uck Cables
Cable

HELUTRUCK

Cables fo
for Wind
nd Po
nd
Power
Pow
ower
wer
er

HELUWIND

KOMPOFLEX

Microbial res
Mi
resistant
sttant Cables
Ca

KOMPOSPEED

Bio-Oil
-O resistant
ntt Cables
C es for Drag
Dra Chains

Lift hoist
oist control Cables
ables

LIFT-TRAGO

Flexible Control
ontr Cables halogen-free (UL/CSA)

MEGAFLEX

MULTIFLEX 512

Cables for Drag Chain


Chains PUR

MULTISPEED

Cables for Drag Chains

SENSORFLEX

Sensor Cables

Cables for photovoltaic

SOLARFLEX

SUPER-PAAR-TRONIC-C-PUR

Cables for Drag Chains halogen-free

SUPERTRONIC

Cables for Drag Chains

THERMFLEX

Heat resistant Cables

Servo, Feedback and Motor Cables

TOPFLEX

Servo, Feedback and Motor Cables

TOPSERV

TRAYCONTROL

Cable for open installation, exposed run

TROMMPUR

Trailing Cables

Flexible Control Cables PUR

UNIPUR

DATA, NETWORK AND BUS TECHNOLOGY


HELUCOM

Fibre optic Cables


Fibre optic connecting equipment

HELUKAT

Copper data Cables


Copper connecting equipment

MEDIA TECHNOLOGY
Cables for light control
Audio Cables

CABLE ACCESSORIES
HELUCHAIN

Cables for Drag Chains program

HELUTEC

Industrial connectors series

HELUTOP

Cable glands program

HELUROBOTICS
HELUROBOTICS

Pre-assembled dress package systems for Robotics

16
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Achieving Success through Quality and Innovation

Product certicates document the


tested quality level of our products
ISO 9000ff is used as the basis for quality
management processes carried out at
HELUKABEL. Product certicates issued
by accredited institutions also make it
easier for you to evaluate your suppliers.

Our continuous quality improvement process


enables us not only to maintain a consistently
high quality standard, it also ensures
continued development and new product
development.
Our commitment to protexting the
environment can be seen in our-rate
environment management systems.

17
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

CCC-Certication for China


The HELUKABEL GmbH had obtain for their products the CCC-Certication for the following products:
PVC insulated and PVC sheathed
oil-resistant exible cables according
to GB 5023.7-1997 227 IEC 74 (RVVYP)
300/500V 0,5-2,5 mm2 (2-60 cores)
227 IEC 75 (RVVY) 300/500V
0,5-2,5 mm2 (2-60 cores)
Colour: grey
H05 VV5-F
H05 VVC4V5-K

PVC insulated non-sheathed


calbes and wires according to
GB 5023.3-1997
227 IEC 02 (RV) 450/750 1,5-240 mm2
227 IEC 06 (RV) 300/500 0,5-1 mm2
H05 V-K
H07 V-K

PVC insulated exible calbes


and wires according to
GB 5023.5-1997
227 IEC 06 (RV) 300/500 0,75-2,5 mm2
(2-41 cores)
JZ-500, OZ-500, JB-500, OB-500,
Y-CY-JZ, Y-CY-OZ, Y-CY-JB, Y-CY-OB
SY-JZ, SY-OZ, SY-JB, SY-OB
JZ-HF, OZ-HF, JZ-HF-CY, OZ-HF-CY
F-CY-JZ, F-CY-OZ, OZ-BL, OZ-BL-CY

18
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Clean Room Qualied Cables


Type

Page

Type

Page

F-CY-JZ
F-CY-OZ (LiY-CY)
(H)05 Z1Z1-F
JB-500
JB-750 HMH
JB-750
JZ-500
JZ-500 HMH
JZ-500 HMH-C
JZ-600
JZ-602

A 27 - A 28
A 25 - A 26
A 70
A 21
A 68
A 22 - A 23
A 6 - A 10
A 62 - A 63
A 71 - A 72
A 16 - A 17
N7-N8

JZ-602-CY
JZ-750
JZ-HF
JZ-HF-CY
MULTIFLEX 512-C-PUR
MULTIFLEX 512-PUR
MULTISPEED 500-C-TPE
MULTISPEED 500-TPE
SY-JB
SY-JZ

N 17 - N 18
A 14 - A 15
C5-C6
C8-C9
C 19 - C 20
C 14 - C 15
C 24
C 22 - C 23
A 40 - A 41
A 34 - A 35

HELUKABEL goes Clean Room


HELUKABEL, one of the leading worldwide sources of cables,
connections and cable accessories is working to consolidate
its market position in the eld of energy-saving systems by
the increased application of Clean Room principles.
Various cable types are tested under Clean Room conditions
for cleanliness and suitability for use in Clean Rooms, in
co-operation with the Fraunhofer Institute for Production
Techniques and Automation.
As a result of measurements of airbone particles, classied
according to US Federal Standard, 209E, ISO 14644-1 or
VDI 2083 Page 1, we are able to provide a Statement on
deployment of cables in Clean Room areas.
Simply call us for further information:
we will be happy to advise you.

Please complete in your order type and part-number by cleanroom

19
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

-Cables and Wires


VDW (Verein Deutscher Werkzeugmaschinenfabriken)
association of German tooling and machinery factories) set a study group of representatives from
a number of leading German tools and machinery
manufacturers. This study groups has worked out
solutions for decentralised and standardised installation techniques. Also contributing to this concept
are representatives from the branches in industry
of machinery construction, automobile production,
automation engineering and various suppliers. The
objective here is to realise considerable cost reductions by standardising parts and assemblies (e. g.
cables and wires). This can be achieved by:

For cables and lines, existing standards are used.


However, to increase availability and simplify cable
installation, VDW have specied a certain sheath
colour for the individual areas of application.
It is particularly important for us as manufacturer
and supplier of the products cited above, to be
among those suppliers who can offer DESINAcompliant cables. We therefore stock these for
shortnotice delivery to our customers.

Straightforward assembly for preventing errors


Fast failure diagnosis
Reduction of the expenditure for construction
Reduction of type variety
Increase of availability by reducing the type variety.

We are certain that DESINA will assert itself on the


market because this is a standard for all participating
companies and will be a key for more success.
For us as well.

An overview of DESINA suppliers has been made


available on the Internet by VDW, in which
HELUKABEL is included.

20
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

-Cables
Type

Page

Type

Page

TOPSERV 108 PVC


TOPSERV 112 PVC
TOPSERV 119 PVC
TOPGEBER 511 PVC

N 127
N 128
N 129
N 130

TOPSERV 109 PUR


TOPSERV 113 PUR
TOPSERV 121 PUR
TOPGEBER 512 PUR

N 131
N 132 - N 133
N 134
N 135 - N 136

If you should require further information about DESINA, please call us.

21
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

British Standard
Steel wire armoured cable
is used particularly in the Middle/
Far East Asia.

A particularly high level of mechanical protection is ensured


thanks to the armouring of galvanic round steel wire. The
insulation materials used are PVC, networked polyethylene
(XLPE), or halogen-free materials (LSOH Low Smoke Zero Halogen).
Paper Insulated Lead Cover (PILC) cable variants are in demand in
the medium-voltage and high-voltage area. Lines in accordance
with British Standard are also required for re alarm systems and
emergency lighting systems. Fire-resistant and naturally halogenfree with low smoke density, are criteria that must be satised by
the insulation materials.
However cable and lines in accordance with British Standard,
does not necessarily mean a special production variant. Often
the information relative to permissible temperature ranges,
strand make-up, or nominal voltage classes is hidden behind
the classication. Thus usually after transcoding the required
standard, the supply requirements can be easily satised with
stock products.

22
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Selection tables

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

23
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Selection table exible control cable


Operational criteria
xed installation

Standards

adapted with VDR Reg No.

adapted with HAR approbation

adapted with UL approbation


adapted with CSA approbation

F-C-PUR-JZ

PUR-JZ

JZ-500 PUR

JZ-500-FC-PUR

N9

JZ-603-CY

JZ-603

N17 N48 N46 N51

JZ-602-PUR

JZ-602-C-PUR

JZ-602 PUR DC / AC

SY-JZ

JB-750

JB-500

JZ-750

N7

JZ-600-Y-CY

A9 N120 N121 A16 A24 A36 N10 N20 A14 A21 A22 A10 A23 A34 A40

JZ-600

A8

JZ-602-CY

JB-750 yellow

JZ-500 orange

JZ-600-Y-CY UL/CSA

JZ-600 UL/CSA

JZ-500-C black

Single 600-J/-O

JZ-602

A6

SY-JB

Page
according to DIN / VDE

JZ-500 COLD

JZ-500

exing

Single 600-CY -J/-O

xed installation/exing

JZ-500 black

Cable and conductor description

N19 A43 A52 A44 A54

+ 100 C

+ 75 C

Temperature range

Technical Data

+ 80 C

+ 90 C

+ 70 C
+ 60 C
- 5 C
- 15 C

- 20 C
- 25 C

- 30 C

- 40 C

250 V
300 / 300 V
300 / 500 V

450 / 750 V

Core
insulation
Core
identication

600 / 1000 V
PVC / special PVC

numbering according to DIN VDE 0293

PUR

rubber

colour code according to DIN VDE 0293

JB colour code (varicoloured cores)


Cu-braiding
steel wire braiding
PVC / special PVC

black

special material

orange

yellow

green
blue

transparent
Application in drag chains
Application

PUR

grey

see selection table cable in drag chains / prex page 30 to 35

for intrinsic safety power circuit


warning indication
interlocking purposes
open air
halogen-free

Properties

special material

Outer
sheath

Screening

600 V acc. UL/CSA

Sheath colour

Cable structure

Nominal voltage

- 50 C

chemicals consistant
EMV-preferred type
resistant to weathering effects
abrasion resistance

see selection table exible control cable halogen-free


see selection table chemical resistance in chapter X page X 64and X 65

24
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Selection table exible control cable


Cable and conductor description

Operational criteria

TRAYCONTROL 600-C

TRAYCONTROL 600

TRAYCONTROL 500

TRAYCONTROL 500-C

JZ 604 -YCY TC TRAY CABLE

JZ 604-FCY TC TRAY CABLE

Y-CY-JB

JZ 604 TC TRAY CABLE

Y-CY-JZ

F-CY-JZ

F-CY-OZ (LiY-CY)

(H)05VVC4V5-K

H05VVC4V5-K

(H)05VV5-F

OZ-BL-CY

H05VV5-F

OZ-BL

KOMPOFLEX JZ-500-C

KOMPOFLEX JZ-500

BIOFLEX-500-JZ-C

BIOFLEX-500-JZ

UNIPUR

UNIPUR-CP

H05BQ-F / H07 BQ-F

PUR-YELLOW

PUR-ORANGE

PUR-C-PUR

PUR-750

JZ-600 PUR

JZ-600-YC-PUR

Y-C-PUR-JZ

A56 N49 N52 A51 A60 A46 A47 A48 A49 A58 A84 A85 A87 A88 A80 A81 A11 A13 A29 A31 A25 A27 A32 A38 N25 N33 N34 N27 N35 N30 N37

exing

Page

adapted with VDR Reg No.


adapted with HAR approbation

adapted with UL approbation


adapted with CSA approbation
+ 100 C

+ 90 C
+ 80 C
+ 75 C

+ 60 C

- 5 C
-15 c
- 20 C

- 25 C
- 30 C

- 40 C
- 50 C

450 / 750 V
600 / 1000 V

rubber

numbering according to DIN VDE 0293


colour code according to DIN VDE 0293

JB colour code (varicoloured cores)

Cu-braiding
steel wire braiding

PUR

special material

grey

orange
yellow
green

blue

transparent

see selection table cable in drag chains / prex page 30 to 35

Application in drag chains

for intrinsic safety power circuit


warning indication
interlocking purposes

open air

see selection table exible control cable halogen-free

halogen-free

chemicals consistant

EMV-preferred type
resistant to weathering effects

Properties

see selection table chemical resistance in chapter X page X 64and X 65

Application

black

Sheath colour

PVC / special PVC

Outer
sheath

Cable structure

special material

Core
Screeidentining
cation

PVC / special PVC


PUR

600 V acc. UL/CSA

Core
insulation

300 / 500 V

Nominal voltage

250 V
300 / 300 V

Technical Data

+ 70 C

Temperature range

xed installation/exing

according to DIN / VDE

xed installation

Standards

abrasion resistance

25
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Selection table exible control cable halogen-free


Operational criteria

+ 180 C

+ 145 C

(H)05 Z1Z1-F

(H)03 Z1Z1-F

DATAFLAMM-C-PAAR

DATAFLAMM-C

- 25 C

- 55 C

- 60 C

Nominal voltage

- 20 C

- 50 C after UL/CSA

Operating peak voltage

300 / 300 V
300 / 500 V

600 V acc. UL/CSA

450 / 750 V

core insulation

Special Elastomer

screeCore
ning identication

600 / 1000 V

numbering according to DIN VDE 0293

Outer
sheath

JZ 600 HMH

- 15 C

- 40 C

PUR

Silicon

PE
Special Polymer

colour code according to DIN VDE 0293

JB colour code (varicoloured cores)


Cu-braiding

Silicon

EMV-preferred type

abrasion resistance

red-brown

see selection table cable in drag chains / prex page 30 to 35

Application in drag chains

resistant to weathering effects

yellow

open air

orange

chemicals consistant

PUR

black

steel wire braiding

Special Polymer

colour code according to DIN 47100

grey

Sheath
colour

DATAFLAMM

5 C

- 35 C

Cable strucutre

JB 750 HMH-C

+ 5 C
-

- 30 C

VApplication

JZ 600 HMH-C

+ 70 C

Temperature range

Technical Data

+ 90 C

+ 120 C

Properties

JB 750 HMH

+ 150 C after UL/CSA

+ 80 C

adapted with HAR approbation

adapted with CSA approbation

B23 B24 A69 A70

adapted with VDR Reg No.

adapted with UL approbation

B8

E14 A62 A71 A68 A77 A66 A75

JZ 500 HMH-C

E5

JZ 500 HMH

HELUTHERM 145 MULTI

E19 E10

HELUTHERM 145 MULTI-C

H05SS-F / H05SST-F

THERMFLEX 180 EWKF

THERMFLEX 180 EWKF-C

SiHF-C-Si UL/CSA

SiHF UL/CSA

SiHF-C-Si

E9

SiHF/GL-P

KOMPOFLEX JZ-500

UNIPUR CP

UNIPUR

PUR-C-PUR

E16 E17 N75 N77

Standards

MEGAFLEX 600-C

SiHF

Page
according to DIN / VDE

PUR 750

E7

MEGAFLEX 500

exing

MEGAFLEX 600

N54 N56 N58 N60 A51 A60 A49 A58 A87 A88

xed installation / exing

MEGAFLEX 500-C

KOMPOFLEX JZ-500-C

xed installation

Cable and conductor description



see selection table chemical resistance in chapter X page X 64 and X 65






26
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Cables halogen-free
Type

Page

AIRPORT 400 Hz
BUS-Cables/I-BUS
DATAFLAMM
DATAFLAMM-C
DATAFLAMM-C-Paar
FMGCH (FMGCG)
FMGSGO
FMSGSGO
FZ-LSi, FZ-LS, Neon-Light-Cable
GALVANICABLE
H05Z-K, H07Z-K
H07 ZZ-F
(H)03 Z1Z1-F
(H)05 Z1Z1-F
HELUTHERM 1200
HELUTHERM 1200-ES
HELUTHERM 145
HELUTHERM 145 MULTI
HELUTHERM 145 MULTI-C
HELUTHERM 145 UL/CSA approved
HELUTHERM 145
HELUTHERM 600/600-ES
HELUTHERM 800/800-ES
HELUWIND WK re warning cable Torsion
HELUWIND Thermex 145
J-2Y(St)H
J-H(St)H
J-H(St)HBMK red
JB-750 HMH
JB-750 HMH-C
JE-H(St)H BMK red
JE-H(St)H orange
JE-H(St)HRH BMK
JE-LiHCH
JZ-500 HMH
JZ-500 HMH-C
JZ-600 HMH
JZ-600 HMH-C
KOMPOFLEX JZ-500
KOMPOFLEX JZ-500-C
KOMPOSPEED 600/600-C
KOMPOSPEED JZ-HF-500
KOMPOSPEED JZ-HF-500-C
LFMGSSGO
LFMSGSSGO
LMGSGO
MEGAFLEX 500
MEGAFLEX 500 UL/CSA
MEGAFLEX 500-C
MEGAFLEX 500-C UL/CSA
MEGAFLEX 600
MEGAFLEX 600-C
MGSGO
MULTIFLEX 512-C-PUR
MULTIFLEX 512-PUR
MULTIFLEX 512-PUR UL/CSA
MULTIFLEX 512-C-PUR UL/CSA
MULTISPEED 500-C-PUR UL/CSA
MULTISPEED 500-C-TPE
MULTISPEED 500-C-TPE UL/CSA
MULTISPEED 500-PUR

T 49 - T 50
R 142
B8
B 23
B 24
W7
W8
W9
K 26
T 11
K 16 - K 17
F 12 - F 13
A 69
A 70
K 32
K 32
K 22 - K 23
E5-E6
E 14 - E 15
N 117
N 118
K 30
K 31
T 35
T 39
P 12
P 10
P 11
A 68
A 77 - A 78
Q 29
Q 28
Q 30
B 33
A 62 - A 63
A 71 - A 72
A 66 - A 67
A 75 - A 76
A 87
A 88 - A 89
K 37
C 29
C 30
W 10
W 11
W6
A 64 - A 65
N 54 - N 55
A 73 - A 74
N 56 - N 57
N 58 - N 59
N 60 - N 61
W4
C 19 - C 20
C 14 - C 15
N 87 - N 88
N 92 - N 93
N 94 - N 95
C 24
N 98 - N 99
C 16

Type
MULTISPEED 500-PUR UL/CSA
MULTISPEED 500-TPE
MULTISPEED 500-TPE UL/CSA
MULTISPEED 600-PUR-J/-O
MULTISPEED 600-C-PUR-J/-O
MULTISPEED TRONIC-C-PUR
MULTISPEED TRONIC-PUR
MULTITHERM 400
MULTITHERM 400-ES
(N)HMH-J
(N)HMH-O
N2XCH Power and Control cable
N2XCH-FE 180/E30
N2XCH-FE 180/E90
N2XH Power and Control cable
N2XH-FE 180/E30
N2XH-FE 180/E90
NHXCH-FE 180/E90
NHXCH-FE 180/E30
NHXH-FE 180/E30
NHXH-FE 180/E90
NHXMH-J/-O
NSHXAF
PUR 750
PUR-C-PUR
PUR-Single Core
RD-H(St)H
ROBOFLEX-sewer robot
ROBOFLEX 156-at
ROBOFLEX 150, 151, 152, 153
ROBOFLEX 2001 / 2001-C
Sensorex-H
SiD, SiD/GL, SiF/GL
SiF, SiFF
SiHF
SiHF UL/CSA
SiHF-C-Si UL/CSA
SiHF/GL-P
SOLARFLEX
Ships Power Cables MPRX
Ships Power Cables MPRXCX
SUPER-PAAR-TRONIC-C-PUR
SUPERTRONIC-330-PUR
SUPERTRONIC-330-C-PUR
SUPER-PAAR-TRONIC-340-C-PUR
SUPERTRONIC-C-PUR
THERMFLEX 180 EWKF
THERMFLEX 180 EWKF-C
TOPFLEX 611-PUR
TOPFLEX 611-C-PUR
TOPFLEX MOTOR EMV 1/1
TOPFLEX-PUR
TOPSERV 109 PUR
TOPSERV 110/120
TROMM-PUR
TROMM-PUR-H
UL-Style 3135
UNIPUR
UNIPUR-CP

Page
N 89 - N 90
C 22 - C 23
N 96 - N 97
N 124
N 125
N 106
N 105
E 13
E 20
O8
O7
Q 26 - Q 27
Q 33 - Q 34
Q 41 - Q 42
Q 24 - Q 25
Q 31 - Q 32
Q 39 - Q 40
Q 45 - Q 46
Q 37 - Q 38
Q 35 - Q 36
Q 43 - Q 44
O9
K 36
A 51
A 60
K 15
B 34
H 10
H9
H7-H8
H6
T 46 - T 47
K 25
K 24
E7-E8
N 75 - N 76
N 77
E 16
T 18 - T 19
W 14
W 15
C 35
N 102
N 103
N 104
C 34
E9
E 19
D5
D7
N 147
D 14/D 16
N 131
D9
G5
G4
N 119
A 49 - A 50
A 58 - A 59

27
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Cables to foreign standards


Type

Page
UL/CSA

Page
GOST

A
A07 RN-F
A-BUS

F8
R 147 - R 150

Type

Page
UL/CSA

JZ-600-YC-PUR

N 52-N 53

JZ-600-Y-CY

Page
GOST
A 36-A 37

JZ-600-Y-CY UL/CSA

N 20-N 21

JZ-602

N 7-N 8

N 7-N 8

CAN BUS

R 132-R 141

JZ-602-PUR DC/AC

N 48

N 48

CC LINK BUS

R 157

JZ-602 RC

N 83

N 83

Command Cables UL approved/screened

N 65 - N 73

JZ-602 RC-C-PUR

N 91

D
DREINORM HAR-UL-CSA

N 111-N 112

JZ-602 RC-CY

N 85

JZ-602 RC-PUR

N 86

N 85

JZ-602-C-PUR

N 51

N 51

F-C-PUR-JZ

A 54-A 55

JZ-602-CY

N 17-N 18

N 17-N 18

F-CY-JZ

A 27-A 28

JZ-602-PUR

N 46-N 47

N 46-N 47

F-CY-OZ (LiY-CY)

A 25-A 26

JZ-603

N9

N9

N 113-N 114

JZ-603-CY

N 19

N 19

JZ-604-FCY TC TRAY CABLE

N 33

N 33

JZ-604-TC TRAY CABLE

N 25-N 26

N 25-N 26

N 34

N 34

FIVENORM

N 113-N 114

FOUNDATIONTM Fieldbus Basic, NFPA 79 Ed. 2007

R 122

H
H03 VV-F

A 18

JZ-604-YCY TC TRAY CABLE

H05 RN-F / RR-F

F5

JZ-750

A 14 -A 15

H05 V-K

K 6-K 7

JZ-HF

C 5-C 6

H05VV5-F, (NYSLY-JZ)

A 11-A 12

JZ-HF-CY

C 8-C 9

(H)05VV5-F, ((N) YSLY-JZ)

A 13

H05VVC4V5-K, (NYSLYCY-JZ)

A 29-A 30

KOMPOFLEX JZ-500

A 87

(H)05VVC4V5-K ((N)YSLYCY-JZ

A 31

KOMPOFLEX JZ-500-C

A 88 - A 89

H05VV-F

A 19-A 20

KOMPOSPEED 600

K 37

N 12-N 13

KOMPOSPEED JZ-HF 500

C 29

KOMPOSPEED JZ-HF 500-C

C 30

H05VV-F/SJT

N 12-N 13

H05VV-F/UL

N 14

(H)05 Z1Z1-F

A 70

H07 RN-F

F 6-F 7

MEGAFLEX 500

N 54-N 55

N 54-N 55

H05 V-K / H07 V-K

K 13

MEGAFLEX 500-C

N 56-N 57

N 56-N 57

H07 V-R, H05 V-K, (H)07 V-K

K 12

MEGAFLEX 600

N 58-N 59

K 8-K 9

MEGAFLEX 600-C

N 60-N 61

MULTIFLEX-512-C-PUR

C 19-C 20

C 19-C 20

MULTIFLEX-512-PUR

C 14-C 15

C 14-C 15

H07 V-K, (H)07 V-K


HELUKABEL FOUNDATIONTM

R 122-R 125

HELUTHERM 120

E4

MULTIFLEX 600

N 62

T 27

MULTIFLEX 600-C

N 63

HELUWIND WK 135-Torsion

T 29

MULTISPEED 600 PUR-J/-O

N 124

HELUWIND WK Fire Warning Cables Torsion

T 35

MULTISPEED 600-C-PUR-J/-O

N 125

HELUWIND WK DLO 2kV

T 37

MULTISPEED-500-C-PUR UL/CSA

N 94-N 95

HELUWIND WK H07BN4N4-F WIND-Torison

T 33

MULTISPEED-500-C-PVC UL/CSA

N 84

HELUWIND Thermex 145

T 39

MULTISPEED-500-C-TPE UL/CSA

N 98-N 99

HELUWIND WK (N)A2XH

T 40

MULTISPEED-500-PUR UL/CSA

N 89-N 90

MULTISPEED-500-PVC UL/CSA

N 82

MULTISPEED-500-TPE UL/CSA

N 96-N 97

MULTISPEED-TRONIC-C-PUR

N 106
N 105

HELUTHERM 145 UL/CSA approved

N 117-N 118

HELUWIND WK 103w EMV

T 27

I
I-BUS

R 142 - R 144

J
JB-500

A 21

MULTISPEED-TRONIC-PUR

JB-750

A 22

JB-750 yellow

A 23

N2XH

Q 24-Q 25

JZ-500

A 6-A 7

N2XCH Power and Control cable

Q 26-Q 27

JZ-500 HMH

A 62-A 63

N2XCH-FE 180/E30

Q 33-Q 34

JZ-500 HMH-C

A 71-A 72

N2XH-FE 180/E30

Q 31-Q 32

JZ-500 orange

A 10

N2XH-FE 180/E90

Q 39-Q 40

JZ-500 PUR

A 43

N2XSY

Q 50 -Q 51

JZ-500-FC-PUR

A 52-A 53

N2XS2Y

Q 54-Q 55

JZ-600

A 16-A 17

N2XS(F)2Y

Q 58-Q 59

JZ-600 HMH

A 66-A 67

N2XSEY

Q 62

JZ-600 HMH-C

A 75-A 76

NAYY-J

Q9

JZ-600 UL/CSA

N 10-N 11

NHXCH-FE 180/E30

Q 37 -Q 38

JZ-600-PUR

N 49 -N 50

NHXCH-FE 180/E90

Q 45-Q 46

28
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Cables to foreign standards


Page
GOST

Type

NHXH-FE 180/E30

Q 35-Q 36

SUPERTRONIC-330-PUR

N 102

NHXH-FE 180/E90

Q 43-Q 44

SUPER-PAAR-TRONIC-340-C-PUR

N 104

NYCWY

Q 16-Q 17

SY-JB

A 40 - A 41

NYCY

Q 12-Q 13

SY-JZ

A 34 - A 35

NYM-J/ NYM-O

O5

NYY-J und NYY-O

Q6-Q7

Type

Page
UL/CSA

Page
UL/CSA

TOPFLEX 1002

T7

TOPFLEX 300

T6

OB-BL-PAAR-CY

A 82

TOPFLEX 301/301-C

T9

OZ-BL

A 80

TOPFLEX 302/302-UL

T8

OZ-BL-CY

A 81

TOPFLEX 600-C-PVC

D6

TOPFLEX 600-PVC

P
PAAR-CY-OZ

B 13

TOPFLEX 600 VFD

PAAR-TRONIC

B 6-B 7

TOPFLEX 611-C-PUR

PAAR-TRONIC-CY

B 11-B 12

TOPFLEX 611-PUR

D4
N 137
D7
D5

PROFIBUS

R 107-R 121

TOPFLEX 650 VFD

N 138

PROFlnet Type A, B, C

R 101-R 106

TOPFLEX-EMV-UV-2YSLCYK-J

N 141-N 142

PUR-JZ

A 44-A 45

TOPFLEX-EMV 2YSLCY-J

PUR-JZ-HF

C 12-C 13

TOPFLEX-EMV-3PLUS 2YSLCY-J

PUR-JZ-HF-YCP

C 17-C 18

TOPFLEX-EMV-UV-3PLUS 2YSLCYK-J

N 143-N 144

PUR-YELLOW

A 47

TOPFLEX Motor 103

N 150

PUR-ORANGE

A 46

TOPFLEX Motor EMV 1/1

N 147

D 17-D 18
D 21-D 22

PVC+Nylon-Single cores THHN/THWN

N 115

TOPFLEX Motor EMV 3/3

N 148-N 149

PVC-single cores UL/CSA ap. Style 1007

N 108

TOPSERV 109 PUR

N 131

PVC-single cores UL/CSA ap. Style 1015

N 110

PVC-single cores UL/CSA ap. Style 1569

N 109

N 110

TOPSERV 110

D9

TOPSERV 600 VFD

N 139

RE-2Y(St)YV

B 28

TOPSERV 650 VFD

N 140

RE-2Y(St)YV PiMF

B 29

TRAYCONTROL 300

N 38 - N 39

TRAYCONTROL 300 TP

N 42 - N 43

RG-Coaxial cables

M 4-M 7

ROBOFLEX 150 ... 153

H 7-H 8

TRAYCONTROL 300-C

N 40 - N 41

ROBOFLEX 2001

H6

TRAYCONTROL 300-C TP

N 44 - N 45

ROBOFLEX 2001-C

H6

TRAYCONTROL 500

N 27 - N 28

TRAYCONTROL 500-C

N 35 - N 36

TRAYCONTROL 600

N 30 - N 31
N 37

Rubber/Neoprene Control Cable UL+CSA

N 81

N 131
D9

TOPSERV 120

Page
GOST

SHIPFLEX 109

W 20 - W 21

TRAYCONTROL 600-C

SHIPFLEX 113

W 22

TRONIC (LiYY)

B 4-B 5

SHIPFLEX 121

W 23

TRONIC-CY (LiY-CY)

B 9-B 10

SHIPFLEX 512

W 17

SHIPFLEX 330

W 18

UL-Style 3135

SHIPFLEX 340

W 19

UNIPUR

A 49-A 50

K 24-K 25

UNIPUR-CP

A 58-A 59

E 7-E 8

SiF/SiIF/GL/SIFF/SiD/SiD/GL
SiHF
SiHF UL/CSA

Verteilerex

N 75-N 76

N 119

N 151-N 152

SiHF/GL-P

E 16

Y-CY-JB

A 38-A 39

SiHF-C-Si

E 17-E 18

Y-CY-JZ

A 32-A 33

Y-C-PUR-JZ

A 56 -A 57

SiHF-C-Si UL/CSA

N 77

Single 600-J/-O

N 120

N 120

Single 600-CY-J/-O

N 121

N 121

Single 602-RC-CY-J/-O

N 123

N 123

Single 602-RC-J/-O

N 122

N 122

SOLARFLEX-X PV1-F

T 18

SUPER-PAAR-TRONIC-C-PUR

C 35

SUPERTRONIC-C-PUR

C 34

SUPERTRONIC-C-PVC

C 32

SUPERTRONIC-PVC

C 31

SUPERTRONIC-310-C-PVC

N 101

SUPERTRONIC-310-PVC

N 100

SUPERTRONIC-330-C-PUR

N 103

29
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

5m

JZ-602 RC-C PUR

Single 602-RC-J/-O +CY single core

JZ-602 RC-CY

PUR-JZ-HF

PUR-JZ-HF-YCP

MULTIFLEX 512-PUR

30 m

100 m

5xD

7,5 x D

10 x D

3 m/s
x

15 x D

10 m/s2
x

50 m/s2

PVC special
x

TPE special
x

Inner sheath
x

Cu-braid, Cu-layer
x

PVC special

PUR special

12,5 x D

Nominal
Voltage

450 m

-40
*

in C

Temperature Range

90
*

halogen-free
x

extensively oil resistant


x

oil resistant
x

Jacket ame veterdant


x

radiation resistantat 80/100 Mrad


x

uv-rays

lye

1000 V

300/300 V

10 Mio

5 m/s

x
x

Continuation
The table indicates the main application.
In case of moving cables at higher speeds, over longer distances or higher cycling rates please contact our Technical Support.
Phone +49 7150 9209-0 or techsupport@helukabel.de.
A cycle is a double lift: a representative sample has been tested and measurot in our Test Workshop.
The cycle count is only valid when appropriatel and professionally installed (see the installation advice; rules for connections, page 36, and under permitted environment conditions).

MULTIFLEX 512-C-PUR UL/CSA

MULTIFLEX 512-C-PUR

MULTIFLEX 512-PUR UL/CSA

MULTIFLEX 600-C

MULTIFLEX 600

JZ-HF

JZ-HF CY

JZ-602 RC

JZ-602 RC PUR

15 m

PUR special

Standards

Selection table

10 m (to 25 cores)

Single 602-RC-J/-O single core

TPE special

Outher
Sheath

300/500 V

Core
Insulation

600 V/UL-CSA

Cycle
min.

1 Mio

5 Mio

max.

-30

Speed

max.

2 m/s

4 m/s

D=Outerdiameter

-20

Min. Bending Radius

-5

max.

70

Movement Distance

-10

Resistance

microbes

Technical Data

coolant

Cable Structure

80

Accelaration

VDE-Register-No.

Application

adapted to V DE 0245/0281/0282

Type

DESINA

Control Cable, screened and unscreened

UL/CSA-approved

Other Technical Details can be found in the Product Pages of our Catalogue.

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Cables in drag chains

30

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 500-TPE UL/CSA

MULTISPEED 500-C-PVC

MULTISPEED 500-C-PVC UL/CSA

MULTISPEED 500-C-PUR

MULTISPEED 500-C-PUR UL/CSA

MULTISPEED 500-C-TPE UL/CSA

10 m (to 25 cores)

15 m

30 m

100 m

450 m

5xD

7,5 x D

3 m/s
x

15 x D

5 m/s
x

10 m/s2
x

50 m/s2

10 Mio
x

TPE special
x

Inner sheath
x

Cu-braid, Cu-layer
x

PVC special
x

PUR special

PUR special

PVC special

12,5 x D

10 x D

Outher
Sheath

TPE special

Core
Insulation

Nominal
Voltage

1000 V
x

in C

90
*

halogen-free
x

extensively oil resistant


x

Jacket ame veterdant


x

radiation resistantat 80/100 Mrad


x

uv-rays

lye

oil resistant

-40

300/300 V

The table indicates the main application.


In case of moving cables at higher speeds, over longer distances or higher cycling rates please contact our Technical Support.
Phone +49 7150 9209-0 or techsupport@helukabel.de.
A cycle is a double lift: a representative sample has been tested and measurot in our Test Workshop.
The cycle count is only valid when appropriatel and professionally installed (see the installation advice; rules for connections, page 36, and under permitted environment conditions).

MULTISPEED 500-C-TPE

MULTISPEED 500-PUR

MULTISPEED 500-PVC UL/CSA

MULTISPEED 500-TPE

MULTISPEED 500-PUR UL/CSA

MULTISPEED 500-PVC

5m

MULTISPEED 600-C-PUR-J/-O

min.

1 Mio

5 Mio

max.

300/500 V

Resistance

Standards

Selection table

MULTISPEED 600-PUR-J/-O

max.

2 m/s

4 m/s

D=Outerdiameter

600 V/UL-CSA

max.

-30

Temperature Range

microbes

Technical Data

coolant

Cable Structure

-20

Cycle

-5

Accelaration

-10

Speed

VDE-Register-No.

Application

70

Min. Bending Radius

80

Movement Distance

adapted to V DE 0245/0281/0282

Type

DESINA

Control Cable, screened and unscreened

UL/CSA-approved

Other Technical Details can be found in the Product Pages of our Catalogue.

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Cables in drag chains

31

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

5m

Tachofeedback-Cable-C-Pur

15 m

30 m

100 m

450 m

5xD

7,5 x D

10 x D

12,5 x D

3 m/s
x

15 x D

5 m/s
x

10 m/s2
x

50 m/s2

10 Mio
x

PVC special
x

TPE special
x

PE
x

PUR special
x

Inner sheath
x

Cu-braid, Cu-layer
x

PVC special
x

300/300 V
x

Nominal
Voltage

-40
*

in C

Temperature Range

90
*

halogen-free
x

extensively oil resistant


x

Jacket ame veterdant


x

radiation resistantat 80/100 Mrad


x

uv-rays

lye

oil resistant

1000 V

The table indicates the main application.


In case of moving cables at higher speeds, over longer distances or higher cycling rates please contact our Technical Support.
Phone +49 7150 9209-0 or techsupport@helukabel.de.
A cycle is a double lift: a representative sample has been tested and measurot in our Test Workshop.
The cycle count is only valid when appropriatel and professionally installed (see the installation advice; rules for connections, page 36, and under permitted environment conditions).

POF mit PUR-Jacket, simplex duplex

TOPGEBER 512 PUR

I-BUS Drag chain

PROFIBUS L21x20,64

MULTISPEED-TRONIC-C-PUR

S FTP Drag chain 4x2xAWG 24 PUR

PROFIBUS CAN, high exible

MULTISPEED-TRONIC-PUR

SUPERTRONIC 330 PUR

SUPERTRONIC 330 C PUR

SUPER-PAAR-TRONIC-C-PUR

SUPERTRONIC-C-PUR

SUPER-PAAR-TRONIC 340 C PUR

SUPERTRONIC 310 C-PVC

10 m (to 25 cores)

SUPERTRONIC-PUR

SUPERTRONIC-C-PVC

SUPERTRONIC 310-PVC

PUR special

Standards

x
x

Selection table

SUPERTRONIC-PVC

TPE special

Outher
Sheath

300/500 V

Core
Insulation

600 V/UL-CSA

Cycle
min.

1 Mio

5 Mio

max.

-30

Speed

max.

2 m/s

4 m/s

D=Outerdiameter

-20

Min. Bending Radius

-5

max.

70

Movement Distance

-10

Resistance

microbes

Technical Data

coolant

Cable Structure

80

Accelaration

VDE-Register-No.

Application

adapted to V DE 0245/0281/0282

Type

DESINA

Elektronic-Data-BUS-Cables, screened and unscreened

UL/CSA-approved

Other Technical Details can be found in the Product Pages of our Catalogue.

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Cables in drag chains

32

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPSERV 113 PUR

TOPSERV 121 PUR

TOPFLEX 300

TOPFLEX 301

TOPFLEX 301 C

TOPFLEX 304

TOPSERV 110+120 w. Control pair. screened x

30 m

5xD

7,5 x D

10 x D

x
x

3 m/s
x

15 x D

10 m/s2
x

50 m/s2

PVC special
x

TPE special
x

Inner sheath
x

Cu-braid, Cu-layer
x

PVC special
x

PUR special

PUR special

12,5 x D

Outher
Sheath

TPE special

Core
Insulation

Nominal
Voltage

1000 V
x

-40
*

in C

90
*

halogen-free
x

extensively oil resistant


x

oil resistant
x

Jacket ame veterdant


x

radiation resistantat 80/100 Mrad


x

uv-rays

lye

300/300 V

10 Mio

5 m/s

450 m

100 m

The table indicates the main application.


In case of moving cables at higher speeds, over longer distances or higher cycling rates please contact our Technical Support.
Phone +49 7150 9209-0 or techsupport@helukabel.de.
A cycle is a double lift: a representative sample has been tested and measurot in our Test Workshop.
The cycle count is only valid when appropriatel and professionally installed (see the installation advice; rules for connections, page 36, and under permitted environment conditions).

TOPFLEX 611-C-PUR

15 m

TOPFLEX 611 PUR

10 m (to 25 cores)

TOPFLEX 304 C

5m

min.

1 Mio

5 Mio

max.

300/500 V

Resistance

Standards

Selection table

TOPSERV 109 PUR

max.

2 m/s

4 m/s

D=Outerdiameter

600 V/UL-CSA

max.

-30

Temperature Range

microbes

Technical Data

coolant

Cable Structure

-20

Cycle

-5

Accelaration

-10

Speed

VDE-Register-No.

Application

70

Min. Bending Radius

80

Movement Distance

adapted to V DE 0245/0281/0282

Type

DESINA

Servo Cables and Motor Cables, screened and unscreened

UL/CSA-approved

Other Technical Details can be found in the Product Pages of our Catalogue.

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Cables in drag chains

33

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SHIPFLEX 121

10 m (to 25 cores)

15 m

30 m

100 m

5xD

7,5 x D

15 x D

10 x D

10 m/s2
x

50 m/s2

10 Mio
x

TPE special
x

Inner sheath
x

Cu-braid, Cu-layer
x

PVC special

PUR special

PVC special

3 m/s

12,5 x D

300/300 V
x

Nominal
Voltage

450 m

1000 V
x

-40
*

in C

Temperature Range

90
*

halogen-free
x

oil resistant
x

lye
x

radiation resistantat 80/100 Mrad


x

uv-rays

Jacket ame veterdant

extensively oil resistant

5 m/s

The table indicates the main application.


In case of moving cables at higher speeds, over longer distances or higher cycling rates please contact our Technical Support.
Phone +49 7150 9209-0 or techsupport@helukabel.de.
A cycle is a double lift: a representative sample has been tested and measurot in our Test Workshop.
The cycle count is only valid when appropriatel and professionally installed (see the installation advice; rules for connections, page 36, and under permitted environment conditions).

SHIPFLEX 109

SHIPFLEX 340

SHIPFLEX 109

SHIPFLEX 330

SHIPFLEX 113

SHIPFLEX 512

Ship Cables

KOMPOSPEED JZ-HF-500

KOMPOSPEED JZ-HF-C-500

KOMPOSPEED 600

KOMPOSPEED 600-C

5m

BIOFLEX 500 JZ-HF-C

PUR special

Standards

Selection table

BIOFLEX 500 JZ-HF

TPE special

Outher
Sheath

300/500 V

Core
Insulation

600 V/UL-CSA

Cycle
min.

1 Mio

5 Mio

max.

-30

Speed

max.

2 m/s

4 m/s

D=Outerdiameter

-20

Min. Bending Radius

-5

max.

70

Movement Distance

-10

Resistance

microbes

Technical Data

coolant

Cable Structure

80

Accelaration

VDE-Register-No.

Application

adapted to V DE 0245/0281/0282

Type

DESINA

Environment friendly Cables, screened and unscreened

UL/CSA-approved

Other Technical Details can be found in the Product Pages of our Catalogue.

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Cables in drag chains

34

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

For installation of the chain please observe the manufacturers advice.

Certied for Clean Room use

Clean room cables


JZ-HF-CY
MULTIFLEX 512-C-PUR
MULTISPEED 500-C-TPE

Robotic cables
MULTISPEED 500
ROBOFLEX 2001 / 2001 C
(for movement in 3 dimensions)

ECO Cable
KOMPOSPEED JZ HF500+C
KOMPOSPEED 600+C
BIOFLEX 500 JZ H+C

Servo and Motor cables


TOPSERV 100 bis 124
TOPFLEX 116
TOPFLEX 611-PUR+611-C-PUR

Data cables
SUPERTRONIC-PUR+C-PUR
SUPER-PAAR-TRONIC-C-PUR
SUPERTRONIC-PVC+C-PVC
TOPGEBER 500+502+503+510
Tachofeedback-cable -C-PUR
Incremental feddback cable -C-PUR

Control and connecting cables


JZ+HF+CY
PUR-JZ-HF+YCP
MULTIFLEX 512-PUR+C-PUR
MULTISPEED 500+C (alle Typen)
JZ-602 RC+CY

All cables and chains in elds


of the same colour can be used
in combination.

HELUKABEL for drag chains

IPA Certicate

E-Band
E6

Easy Triex
Twister Chain

E2R
E4/0
E4/4
E 4 / 100
E6

Zipper
Easy-Chain
E 2 micro
E 2 mini
E 2 medium
E 2 R 100

IGUS

IPA Certicate

Quantum

Robotrax

XLC
Prole
Quantum

Mono
Uniex
KC
KE
MC
ME/MK

Kabelschlepp

IPA Certicate

Reintec

Interex K

PFR
PKK
PLE
Kolibri

EKD
Gelenkrohr

IPA Certicate

MP 44

MP
Rotary
movement
on request

MP-Serie

Murrplastik

Drag chains Type from

IPA Certicate

SR 305 A

Robot Serie

Serie Steel

Serie SR
Light
Medium
Heavy
Sliding
Protection

BS Brevetti
Stendalto

IPA Certicate

PL35-34
PL35-44
PL35-64
PL35-79
PL 35-109

Available
on request

S 10 / SUT 10
S 12 / SUT 12
S 17

P/PL/PLT
PC
PCT
PCA
S5
S 7 / SUT 7

Flexatec

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Selection Table for Energy Drag Chains

The mentioned types, brands and certications represent our state of knowledge. Changes are possible.

35

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Installation manual
Cable installation in drag chains
The control cables in drag chains undertake an important task for the controlling and power technique, must be good synchronized with
each other in the power chain systems. Further the installation of the cables and predection tubes in the power drag chains must be
conducted with great care. An efcient usage upon accurate and exact cable installation. The following basic points should be noticed:

1. Where at and round cables are mixed in one drag tray, then these should be installed
loosely next to one another. The guide stays should be installed between the cables laid
side by side. Try and avoid placing different sizes of round cables next to one another.
Due to the limited space relationship cables arranged one above the other, frame stays
are to be installed.
2. The cables must be installed with guide stays, dividers or in separate hole stays so as to
move freely in the drag tray guides. As free space for the cables in the guide stay
should be at least 10% of the cable .
3. Always ensure that the cable can follow the drag trays motions without appearing to
be forced.
4. If the cables are to be installed in the drag tray in layers then it is important to check
upon installation that the cables are laid in such a way that they do not block eachother
when the drag tray alters direction.
5. Cables should always be installed in nonkinking and nontwisting at position into the
dray trays. The cables must be reeled down tangential from the reels or drums;
the cables should not be lifted up in twisted or looping form over head. Before the
installation, the cables must be laid in straight and non-twisted form on plane surface.
The cables must have an additional length of at least 10% of the whole length so that
these can be laid freely without twisting in drag chains.
6. In case that is not possible to lay the cables as described under a,
in order to lay several
multi core high exible cables with an outer diameter < 10 mm, we recommend
the use of a guiding tube, in which these cables should losely laied. This tube is than
integrated into the drag system.
The cross section of this tube has to be much larger as the sum of the cross sections of
the cables. For the free movement of the exible energy conduits, the guide or divider
stays must be installed.

energy conduit

7. In case that pressure- or hydraulic tubes are integrated in a power drag


system, those should be able to expand and to shrink under alternating charges
without interrupting the functionability of the drag system.
8. In order to maintain a balanced running of the drag chain it is necessary to ensure that
the weight of the cables inside is divided up evenly, with the heavier cables installed on
the edges and the lighter types in the middle.
All cables must be securely xed at one end of the drag chain. Thus assuring that the
cores are securely fastened to one side with the other, open, side allow-ing enough
slack to take up the drag chains motion.
Generally it is recommended, if possible, not to use cables with a multi layer
construction, e.g. >25 cores, but to split the necessary number of conductors over
several cables.

If you have any further questions


please call our special cable department.

36
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Please send inquiry to:


MARYLAND METRICS
P.O. Box 261
Owings Mills, MD 21117 USA
ph: (410)358-3130 (800)638-1830
fx: (410)358-3142 (800)872-9329
email: sales@mdmetric.com
web: http://mdmetric.com

Questionnaire for
Energy Drag Chain Systems
Customer

Sender
Installation site
Kind of machine

Contact

In operation since

Phone

Fax

date

1. Drag Chain-Parameter

2. Installation and Movement-Parameter

1. Chain length/chain width

m/mm

1. Movement distance (max.)

2. Chain pitch

mm

2. Speeds

m/s

3. Bending radius

mm

3. Acceleration

m/s2

4. Guide stays existing

Tyes

Tno

4. Frequency per time unit

x/h

5. Frame stays existing

Tyes

Tno

5. Average movement distance/cycle m

6. Layout/Installation

Thorizontal

Tvertical

6. Daily working duration

7. Feeding at mid of moving distance Tyes


8. Addtional weight/chain

Tno

kg

3. Cable-Parameter
1. Cable length (total)

2. Cable length (mobile)

4. Environmental-Parameter

3. Number of cables

1. Operating temprature

4. Cable clamping without strain

Tyes

5. Number of cores per cable

6. Cable screened
7. Cable halogen-free

Tno

2. Kind of chemical inuences

Tyes

Tno

3. Other environmental inuences

Tyes

Tno

L = Movement distance
R = Radius
E = Distance between cable entrance
and mid of moving distance

Fix bracket

5. Cross-section and size of power cables


No.

Part-No.

Cable type

No. cores/cross-sec.

Notes

1.

2.

3.

37
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Assembly instructions/laying reel cables


NSHTU / (N)SHTU

Correct

Incorrect
1. The cables are to be pulled from the reeling drum without
twisting, using a drawing cable and cable grip. Deflecting
or pulling the cable over edges should be avoided.

In the case of rings, the cable should be unwound


tangential.

Correct

Incorrect
2. The cables must always be attached to the equipment
drum without torsion.
Select the largest possible distance between the reeling
drum and operating drum.

Correct

Incorrect
4. The cables are to be rolled onto the operating drums
so that the cable moves to the left when started.

Correct

Incorrect
5. The S-shaped deflection of cables is to be avoided.

Correct
6. 2-3 windings on the operating drum must remain when
the cable is extended.

Correct

7. In order to avoid crushing when fixing the cable to the


end, a cable grip is to be used.

38
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Please send inquiry to:


MARYLAND METRICS
P.O. Box 261
Owings Mills, MD 21117 USA
ph: (410)358-3130 (800)638-1830
fx: (410)358-3142 (800)872-9329
email: sales@mdmetric.com
web: http://mdmetric.com

Record form for


reel cables
Customer

Sender
Installation site
Type of machine

Contact

In operation since

Phone

Fax

Date

1. Drum configuration
1.1. Monospiral

1.2. Single layer

1.3. Multi layer

2. Arrangement of cables
2.1. Horizontal

2.2. Vertical

2.3. With deflection

2.4. Feed

2.5. Feed

2.6. Different feed (please enclose sketch or photo)

3. Track end cable fixing

4. Motion parameters

3.1. Cable grip

4.1. Travel (m)

3.2. Clamp

4.2. Travel speed (m/s)

3.3. Other

4.3. Travel acceleration (m/s)


4.4. Number of cycles/time unit

39
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Selection table

low voltage joints

NYY-J 1X16RE
NYY-J 1X25RM
NYY-J 1X35RM

NYY-J 1X50RM
NYY-J 1X70RM
NYY-J 1X95RM

NYY-J 1X150RM
NYY-J 1X185RM
NYY-J 1X240RM
NYY-J 1X300RM

NYY-J 3X2,5RE
NYY-J 3X4RE
NYY-J 3X6RE
NYY-J 3X10RE

NYY-J 3X16RE
NYY-J 3X25RM

NYY-J 3X70SM
NYY-J 3X95SM
NYY-J 3X120SM

NYY-J 3X35SM/16RE
NYY-J 3X50SM/25RM

NYY-J 3X70/35SM
NYY-J 3X95/50SM
NYY-J 3X120/70SM
NYY-J 3X150/70SM
NYY-J 3X185/95SM
NYY-J 3X240/120SM
NYY-J 4X1,5RE
NYY-J 4X2,5RE
NYY-J 4X4RE
NYY-J 4X6RE
NYY-J 4X10RE

NYY-J 4X16RE
NYY-J 4X25RM

NYY-J 4X35SM
NYY-J 4X50SM

NYY-J 4X70SM
NYY-J 4X95SM
NYY-J 4X120SM
NYY-J 4X150SM
NYY-J 4X185SM
NYY-J 4X240SM
NYY-J 5X1,5RE
NYY-J 5X2,5RE
NYY-J 5X4RE
NYY-J 5X6RE
NYY-J 5X10RE
NYY-J 5X16RE
NYY-J 5X25RM
NYY-J 7X1,5RE
NYY-J 10X1,5RE
NYY-J 12X1,5RE
NYY-J 14X1,5RE
NYY-J 16X1,5RE
NYY-J 19X1,5RE
NYY-J 21X1,5RE
NYY-J 24X1,5RE

NSVM-SVK 75x1,5-2,5

NSVM-SVK 40x1,5-2,5

NSVM-SVK 21x1,5-2,5

NSVM-SVK 14x1,5-2,5

NSVM-SVK 7x1,5-2,5

NSVM-S 4x95/50-4x240/120

NSVM-S 4x50/25-4x95/50

NSVM-S 4x16/16-4x35/16

NSVM-S 4x95-300

NSVM-S 3x95-300

NSVM-S 1x95-300

NYY-J 3X50SM

NYY-J 3X25RM/16RE

NSVM-S 1x95-100

NYY-J 1X120RM

NYY-J 3X1,5RE

NSVM-S 3x70-150

NSVM-S 4x35-150

NSVM-S 3x35-150

NSVM-S 1x35-95

NSVM-S 5x16-35

NSVM-S 4x16-50

NSVM-S 3x16-50

NSVM-S 1x16-35

NSVM-S 5x6-16

NSVM-S 4x6-25

NSVM-S 3x6-25

NSVM-S 5x1,5-6

NSVM-S 4x1,5-10

Cable

NSVM-S 3x1,5-10

joints

40
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Selection table

low voltage joints

NYY-J 40X1,5 QMM

NYY-J 10X2,5RE
NYY-J 12X2,5RE
NYY-J 14X2,5RE

NYY-J 16X2,5RE
NYY-J 19X2,5RE
NYY-J 21X2,5RE

NYY-J 24X2,5RE
NYY-J 30X2,5RE
NYY-J 40X2,5RE

NYY-O 1X16RE
NYY-O 1X25RM
NYY-O 1X35RM

NYY-O 1X50RM
NYY-O 1X70RM
NYY-O 1X95RM

NYY-O 1X150RM
NYY-O 1X185RM
NYY-O 1X240RM
NYY-O 1X300RM
NYY-O 1X400RM

NYY-O 4X1,5RE
NYY-O 4X2,5RE
NYY-O 4X4RE
NYY-O 4X6RE
NYY-0 4X10RE

NYY-O 4X16RE
NYY-O 4X25RM
NYY-O 4X35SM
NYY-O 4X50SM
NYY-O 4X70SM
NYY-O 4X95SM
NYY-O 4X120SM
NYY-0 4X150SM
NYY-O 4X185SM
NYY-O 4X240SM

NYY-O 5X1,5RE
NYY-O 5X2,5RE
NYY-O 5X4RE
NYY-O 7X1,5RE

NYY-O 14X1,5RE

NYY-O 7X2,5RE
NYY-O 10X2,5RE
NYY-O 12X2,5RE
NYY-O 14X2,5RE
NYY-O 16X2,5RE
NYY-O 19X2,5RE

NYY-O 1X120RM

NYY-O 3X1,5RE

NYY-J 52X2,5RE

NYY-O 24X2,5RE
NYY-O 30X2,5RE
NYY-O 40X2,5RE
NYY-J 61X1,5RE
NYCY 0,6/1KV 3X1,5
NYCY 0.6/KV 3X2,5 RE
NYCY 0,6/1KV 3X4RE
NYCY 0,6/1KV 3X6RE
NYCY 0,6/1KV 3X10RE

NSVM-SVK 75x1,5-2,5

NYY-J 30X1,5RE

NYY-J 7X2,5RE

NSVM-SVK 40x1,5-2,5

NSVM-SVK 21x1,5-2,5

NSVM-SVK 14x1,5-2,5

NSVM-SVK 7x1,5-2,5

NSVM-S 4x95/50-4x240/120

NSVM-S 4x50/25-4x95/50

NSVM-S 4x16/16-4x35/16

NSVM-S 4x95-300

NSVM-S 3x95-300

NSVM-S 1x95-300

NSVM-S 1x95-100

NSVM-S 3x70-150

NSVM-S 4x35-150

NSVM-S 3x35-150

NSVM-S 1x35-95

NSVM-S 5x16-35

NSVM-S 4x16-50

NSVM-S 3x16-50

NSVM-S 1x16-35

NSVM-S 5x6-16

NSVM-S 4x6-25

NSVM-S 3x6-25

NSVM-S 5x1,5-6

NSVM-S 4x1,5-10

Cable

NSVM-S 3x1,5-10

joints

41
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Selection table

low voltage joints

NYCY 0,6/1KV 4X2,5RE


NYCY 0,6/1KV 4X4RE
NYCY 0,6/1KV 4X6RE
NYCY 0,6/1KV 4X10RE

NYCY 0,6/1KV 5X2,5RE


NYCY 0,6/1KV 5X4RE
NYCY 0,6/1KV 5X6RE

NYCY 0,6/1KV 5X10/RE

NYCWY 0,6/1KV 3X16


NYCWY 0,6/1KV 3X25RM
NYCWY 0,6/1KV 3X35SM
NYCWY 0,6/1KV 3X50SM

NYCWY 0,6/1KV 3X70SM


NYCWY 0,6/1KV 3X95SM
NYCWY 0,6/1KV 3X120S
NYCWY 0,6/1KV 3X150S
NYCWY 0,6/1KV 3X185S
NYCWY 0,6/1KV 3X240S

NYCWY 0,6/1KV 3X25R


NYCWY 0,6/1KV 3X35SM
NYCWY 0,6/1KV 3X50SM

NYCWY 0,6/1KV 3X70SM


NYCWY 0,6/1KV 3X95 S
NYCWY 0,6/1KV 3X120
NYCWY 0,6/1KV 3X150
NYCWY 0,6/1KV 3X185
NYCWY 0,6/1KV 4X10RE

NYCWY 0,6/1KV 4X35SM


NYCWY 0,6/1KV 4X50SM
NYCWY 0,6/1KV 4X70SM
NYCWY 0,6/1KV 4X95SM
NYCWY 0,6/1KV 4X120S
NYCWY 0,6/1KV 4X150S
NYCWY 0,6/1KV 4X185S
NYCWY 0,6/1KV 4X240S

NYY-J 3X150SM

NYY-J 3X240SM

NYY-O 3X150SM
NYY-O 3X185SM
NYY-O 3X240SM

NYCWY 0,6/1KV 3X240


NYY-J 5 X 35 QMM

NAYY-J 4 X 5O QMM
NAYY-J 4 X 70 QMM
NAYY-J 4 X 95 QMM
NAYY-J 4 X 120 QMM
NAYY-J 4 X 150 QMM
NAYY-J 4 X 185 QMM
NAYY-J 4 X 240 QMM

NSVM-SVK 75x1,5-2,5

NSVM-SVK 40x1,5-2,5

NSVM-SVK 21x1,5-2,5

NYY-J 3X185SM

NAYY-J 4 X 35 QMM

NSVM-SVK 14x1,5-2,5

NYCWY 0,6/1KV 4X25RM

NAYY-J 4 X 25 QMM

NSVM-SVK 7x1,5-2,5

NYCWY 0,6/1KV 4X16RE

NAYY-J 4 X 16 QMM

NSVM-S 4x95/50-4x240/120

NYY-J 3X300/150SM
NYCWY 0.6/1KV 3X10

NSVM-S 4x50/25-4x95/50

NYCY 0,6/1KV 4X16RE


NYCY 0,6/1KV 5X1,5RE

NSVM-S 4x16/16-4x35/16

NSVM-S 4x95-300

NSVM-S 3x95-300

NSVM-S 1x95-300

NSVM-S 1x95-100

NSVM-S 3x70-150

NSVM-S 4x35-150

NSVM-S 3x35-150

NSVM-S 1x35-95

NSVM-S 5x16-35

NSVM-S 4x16-50

NSVM-S 3x16-50

NYCY 0,6/1KV 3X16RE


NYCY 0,6/1KV 4X1,5RE

NSVM-S 1x16-35

NSVM-S 5x6-16

NSVM-S 4x6-25

NSVM-S 3x6-25

NSVM-S 5x1,5-6

NSVM-S 4x1,5-10

Cable

NSVM-S 3x1,5-10

joints

42
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Industrial Cables and Wires

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Flexible Control Cables

A1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Flexible Control Cables


For generations people have tried to build
machines and plants which take on different
functions. To raise, sink, slide, drill, transport and
much more, and have attained fantastic results.
Today we control, inform, weld, pack and transport
automatically by electric control and data cables.
These cables are necessary to ensure a frictionless
ow of data and material. We are able to offer
most of these cables for many applications.
On the following pages we present cables for the
corresponding applications.
If you cant nd a suitable cable in our catalogue,
we can fabricate this special cable on request
already from 100 m or maybe we can offer you a
similar cable from our stock.

HELUKABEL has one of the biggest stocks of


special and standard cables in Germany and
excellent logistics and wants to prove itself every
day.

Stocks in:
Hemmingen/Stuttgart, Neuenhagen/Berlin,
Pleia/Chemnitz, Windsbach/Nuremberg.

A2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description

Page

PVC Control Cables


JZ-500,flexible, number coded, meter marking ...............................................................................................................................
JZ-500 COLD,flexible at low temperature, number coded, meter marking ...........................................................................................................
JZ-500 black,flexible, meter marking........................................................................................................................................................
JZ-500 orange,flexible, orange cores, control cable for interlocking purposes, meter marking .......................................................................
H05VV5-F (NYSLY-JZ),flexible, number coded, oil resistant, meter marking .....................................................................................
(H)05VV5-F ((N)YSLY-JZ),flexible, number coded, oil resistant, meter marking ......................................................................................
JZ-750,flexible, number coded, 750V, meter marking ............................................................................................................................
JZ-600,flexible, number coded, 0,6/1kV, meter marking ............................................................................................................................
H03VV-F,according to DIN VDE 0281 ..........................................................................................................................................
H05VV-F,according to DIN VDE 0281 ...........................................................................................................................................
H05VV-F,according to DIN VDE 0281 ...........................................................................................................................................
JB-500,flexible, colour coded, meter marking ................................................................................................................................
JB-750,flexible, colour coded, 750V, meter marking ..............................................................................................................................
JB-750 yellow,flexible, colour coded, 750V, connection cable for warning indication, meter marking ....................................................................
JZ-500-C black,EMC-preffered type, Cu-screened, flexible, meter marking..........................................................................................................
F-CY-OZ (LiY-CY),flexible, Cu-screened, EMC-preferred type, meter marking........................................................................................
F-CY-JZ,flexible, Cu-screened, EMC-preferred type, meter marking ......................................................................................................
H05VVC4V5-K (NYSLYCY-JZ),flexible, number coded, oil resistant, EMC-preferred type.....................................................................
(H)05VVC4V5-K ((N)YSLYCY-JZ),number coded, screened, oil resistant, EMC-preferred type....................................................................
Y-CY-JZ,flexible, CU-screened, transparent, EMC-preferred type, meter marking ...........................................................................................
SY-JZ,flexible, number coded, with steel wire braiding, meter marking ...................................................................................................
JZ-600-Y-CY,flexible, number coded, 0,6/1kV, Cu screened meter marking, EMC-preferred type .........................................................................
Y-CY-JB,flexible, CU-screened, transparent, EMC-preferred type, meter marking ..........................................................................................
SY-JB,flexible, colour coded, with steel wire braiding, meter marking ....................................................................................................

A 10
A 11
A 13
A 14
A 16
A 18
A 19
A 20
A 21
A 22
A 23
A 24
A 25
A 27
A 29
A 31
A 32
A 34
A 36
A 38
A 40

PUR Control Cables


JZ-500 PUR,tear and coolant resistant, meter marking ..............................................................................................................................
PUR-JZ,tear and coolant resistant, increased oil resistant, meter marking ......................................................................................................
PUR-ORANGE,high abrasion, coolant resistant, meter marking ....................................................................................................................
PUR-YELLOW,PVC-inner jacket, high abrasion, coolant resistant, meter marking ..............................................................................................
H05 BQ-F / H07 BQ-F (NGMH11Y)...........................................................................................................................................
UNIPUR ,flexible at low temperature, with customer markings, halogen-free, wear resistant, robust, meter marking .............................................
PUR-750,halogen-free, meter marking .......................................................................................................................................................
JZ 500-FC-PUR,EMC-preferred type, tear and coolant resistant, screened, without inner sheath, meter marking .....................................................
F-C-PUR-JZ,tear and coolant resistant, Cu-screened, without inner sheath, increased oil resistant, EMC-preferred type, meter marking ........................
Y-C-PUR-JZ,tear and coolant resistant, Cu-screened, with inner sheath, increased oil resistant, EMC-preferred type, meter marking ..........................
UNIPUR-CP,flexible at low temperature, with customer markings, halogen-free, wear resistant, robust, screened, EMC-preferred type, meter marking ......
PUR-C-PUR,Cu-screened, extrem conditions, halogen-free, EMC-preferred type, meter marking ..............................................................................

A 43
A 44
A 46
A 47
A 48
A 49
A 51
A 52
A 54
A 56
A 58
A 60

A 6
A 8
A 9

A3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
A
Description

Page

Halogen-free Control Cables


JZ-500 HMH,flexible control cable, halogen-free, extremely fire resistant, oil resistant , meter marking..............................................................
MEGAFLEX 500,halogen-free, flame retardant, oil-resistant, UV-resistant, flexible, meter marking .............................................................
JZ-600 HMH,flexible control cable, halogen-free, extremely fire resistant, oil resistant , 0,6/1kV, meter marking.......................................................
JB-750 HMH,flexible control cable, coloured core, halogen-free, extremely fire resistant, oil resistant , meter marking..........................................
(H)03 Z1Z1-F,halogen-free, meter marking ................................................................................................................................................
(H)05 Z1Z1-F,halogen-free, meter marking ................................................................................................................................................
JZ-500 HMH-C,flexible control cable, halogen-free, extremely fire resistant, oil resistant , Cu-screened, EMC-preferred type...................................
MEGAFLEX 500-C,halogen-free, flame retardant, oil-resistant, UV-resistant, flexible, screened, EMC-preferred types, meter marking.................
JZ-600 HMH-C,flexible control cable, halogen-free, extremely fire resistant, oil resistant , 0,6/1kV, screened, EMC-preferred type, meter marking............
JB-750 HMH-C,flexible control cable, coloured core, halogen-free, screened, extremely fire resistant, oil resistant , EMC-preferred type, meter marking.

A 62
A 64
A 66
A 68
A 69
A 70
A 71
A 73
A 75
A 77

PVC Control Cables for Intrinsically Safe Circuits


OZ-BL,outer jacket blue, intrinsic safety, flexible, meter marking................................................................................................................
OZ-BL-CY,outer jacket blue, intrinsic safety, flexible, meter marking..........................................................................................................
OB-BL-PAAR-CY,outer jacket blue, intrinsic safety, EMC-preferred type, meter marking.....................................................................................

A 80
A 81
A 82

Bio-Oil and microbial resistant Cables


BIOFLEX-500 -JZ,Bio-fuel resistant, abrasion resistant, recyclable environment friendly, bio-oil resistant , meter marking...............................................
BIOFLEX-500 -JZ-C,Bio-fuel resistant, abrasion resistant, recyclable environmentfriendly, bio-oil resistant , Cu-screened, EMC-preferred type, meter marking.
KOMPOFLEX JZ-500,halogen-free, microbes resistant, low adhesion, meter marking ....................................................................................
KOMPOFLEX JZ-500-C,halogen-free, microbes resistant, Cu-screened, EMC-preferred type, meter marking .......................................................
NANOFLEX HC*500,cut-resistant, meter marking......................................................................................................................................
NANOFLEX HC*500-C,EMC preferred type, cut-resistant, screened, no inner sheath, meter marking......................................................................
NANOFLEX HC*TRONIC,flexible, colour code to DIN 47100, meter marking.....................................................................................................
NANOFLEX HC*TRONIC-C,EMC preferred type, flexible, colour code to DIN 47100, screened, meter marking............................................................

A 84
A 85
A 87
A 88
A 91
A 92
A 93
A 95

1)

1)

1)

1)

1)

1)

1)

1)

A4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-500
JZ-500 COLD
JZ-500 black
JZ-500 orange
H05VV5-F (NYSLY-JZ)
(H)05VV5-F ((N) YSLY-JZ)
JZ-750
JZ-600
H03VV-F
H05VV-F
JB-500
JB-750
JB-750 yellow
JZ-500-C black
F-CY-OZ (LiY-CY)
F-CY-JZ
H05VVC4V5-K (NYSLYCY-JZ)
(H)05VVC4V5-K ((N)YSLYCY-JZ)
Y-CY-JZ
SY-JZ
JZ-600-Y-CY
Y-CY-JB
SY-JB
Photo: iStockphoto.com/Arno Massee

PVC Control Cables

A5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-500 flexible, number coded, meter marking




Technical data

Cable structure

Properties

Control cables, special PVC


Conformsto DIN VDE 0281, 0293, 0295
Temperature range
flexing -15 C1) to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
1) cold bending test, impact resistance test
at low temperatures, elongation test at low
temperatures. Tested according VDE0473
part811-1-4, EN60811-1-4

Bare copper, fine wire conductors,


according to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Core insulation of special PVC Z 7225
Black cores with continuous white
numbering according to DINVDE0293 (also
available with other core colours)
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-lenght
Outer sheath of special PVC, TM2 to
DINVDE0281 part1 and HD21.1
colour grey (RAL7001)
with meter marking, change-over in 2011

Extensively oil resistant, oil-/ chemical


Resistance- see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
Important for assemblers: We supply any
"desired length" of stranded cores without
outer sheath, core insulation colour acc.
RAL 9005 with number combination acc.
customers requirement.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Please note the cleanroom qualification
when ordering.
screened analogue type:
F-CY-JZ, see pageA27
F-CY-OZ (LiY-CY), see pageA25
Y-CY-JB, see pageA38
Y-CY-JZ, see pageA32

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air, as measuring and control cables in tool machines, conveyor belts, production lines
in machinery production, in air-conditioning and in steel production.
The earth core is laid in the outer layer. Selected PVC-compounds guarantee a good flexibility as well as an economic and fast installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
10001
10002
10003
10004
10005
10006
10007
10008
10009
10010
10011
10172
10012
10013
10014
10015
10183
10016
10017
10018
10019
10020
10021
10022
10023
10024

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4G0,5
4x0,5
5G0,5
5x0,5
6G0,5
7G0,5
7x0,5
8G0,5
8x0,5
10G0,5
12G0,5
12x0,5
14G0,5
16G0,5
18G0,5
20G0,5
21G0,5
25G0,5
30G0,5
32G0,5
34G0,5
40G0,5
42G0,5

Outer
Cop.
approx. mm weight
kg/km
4,9
9,6
5,2
14,4
5,2
14,4
5,6
19,0
5,6
19,0
6,3
24,0
6,3
24,0
6,9
29,0
6,9
33,6
6,9
33,6
7,4
38,0
7,4
38,0
8,3
48,0
8,8
58,0
8,8
58,0
9,7
67,0
10,2
76,0
11,0
86,0
11,5
96,0
11,5
101,0
12,9
120,0
13,8
144,0
14,3
154,0
14,9
163,0
15,6
192,0
16,1
202,0

Weight
approx.
kg/km
40,0
46,0
46,0
56,0
56,0
65,0
65,0
75,0
80,0
80,0
97,0
97,0
116,0
135,0
135,0
150,0
175,0
196,0
215,0
240,0
270,0
310,0
323,0
362,0
434,0
449,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20


Part no.
10025
10169
10026
10027
10028
10029
10030
10031
10032
10033
10034
10035
10036
10037
10177
10038
10039
10040
10173
10041
10042
10043
10044
10045
10046
10047

No.cores x
cross-sec.
mm
50G0,5
52G0,5
61G0,5
65G0,5
80G0,5
100G0,5
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
6G0,75
6x0,75
7G0,75
7x0,75
8G0,75
8x0,75
9G0,75
10G0,75
12G0,75
12x0,75
14G0,75
15G0,75
18G0,75

Outer
Cop.
approx. mm weight
kg/km
17,9
240,0
17,9
252,0
19,0
293,0
19,7
312,0
21,8
384,0
24,3
480,0
5,3
14,4
5,6
21,6
5,6
21,6
6,3
28,8
6,3
29,0
6,9
36,0
6,9
36,0
7,5
43,0
7,5
43,0
7,5
50,0
7,5
50,0
8,2
58,0
8,2
58,0
8,8
65,0
9,2
72,0
9,8
86,0
9,8
86,0
10,6
101,0
11,4
108,0
12,2
130,0

Weight
approx.
kg/km
513,0
534,0
625,0
682,0
780,0
980,0
46,0
54,0
54,0
66,0
66,0
80,0
80,0
99,0
99,0
110,0
110,0
130,0
130,0
153,0
162,0
179,0
179,0
214,0
218,0
257,0

AWG-No.
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18

Continuation

A6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-500 flexible, number coded, meter marking




Part no.
10533
10048
10049
10050
10534
10051
10052
10182
10053
10054
10055
10056
10057
10178
10058
10059
10060
10061
10062
10063
10064
10065
10066
10067
10068
10069
10070
10071
10180
10170
10072
10073
10074
10075
10076
10174
10197
10077
10184
10179
10175
10078
10176
10196
10198
10168
10079
10080
10199
10081
10167
10082
10083
10084
10085
10086
10087
10088
10089
10090
10091
10092
10093
10094
10095
10096
10097
10098
10099
10100
10101
10181
10102
10103
10104
10105

No.cores x
cross-sec.
mm
19G0,75
20G0,75
21G0,75
25G0,75
27G0,75
32G0,75
34G0,75
37G0,75
40G0,75
41G0,75
42G0,75
50G0,75
61G0,75
65G0,75
80G0,75
100G0,75
2x1
3G1
3x1
4G1
4x1
5G1
5x1
6G1
7G1
7x1
8G1
9G1
10G1
10x1
12G1
12x1
14G1
16G1
18G1
18x1
19G1
20G1
20x1
21G1
24G1
25G1
25x1
26G1
27G1
30x1
34G1
36G1
37G1
40G1
40x1
41G1
42G1
50G1
56G1
61G1
65G1
80G1
100G1
2x1,5
3G1,5
3x1,5
4G1,5
4x1,5
5G1,5
5x1,5
6G1,5
7G1,5
7x1,5
8G1,5
9G1,5
10G1,5
11G1,5
12G1,5
12x1,5
14G1,5

Outer
Cop.
approx. mm weight
kg/km
12,7
137,0
12,7
144,0
12,7
151,0
14,3
180,0
15,2
195,0
15,9
230,0
16,7
245,0
17,2
266,0
17,2
288,0
18,0
296,0
18,0
302,0
19,8
360,0
21,2
439,0
21,7
468,0
24,3
576,0
27,0
720,0
5,6
19,2
5,9
29,0
5,9
29,0
6,6
38,4
6,6
38,4
7,3
48,0
7,3
48,0
8,1
58,0
8,1
67,0
8,1
67,0
8,7
77,0
9,8
86,0
9,8
96,0
9,8
96,0
10,4
115,0
10,4
115,0
11,4
134,0
12,3
154,0
12,9
173,0
12,9
173,0
13,0
182,0
13,7
192,0
13,7
192,0
13,7
205,0
14,7
230,0
15,4
240,0
15,4
240,0
15,6
252,0
15,8
259,0
16,4
308,0
17,9
326,0
17,9
346,0
18,4
355,0
18,5
384,0
18,5
384,0
19,4
394,0
19,4
403,0
21,2
480,0
21,9
538,0
22,5
586,0
23,5
628,0
26,0
768,0
29,2
960,0
6,4
29,0
6,8
43,0
6,8
43,0
7,4
58,0
7,4
58,0
8,3
72,0
8,3
72,0
9,2
86,0
9,2
101,0
9,2
101,0
9,9
115,0
10,9
129,0
10,9
144,0
12,0
158,0
12,0
173,0
12,0
173,0
13,0
202,0

Weight
approx.
kg/km
264,0
286,0
320,0
365,0
382,0
455,0
510,0
537,0
595,0
607,0
612,0
735,0
845,0
895,0
1070,0
1322,0
60,0
72,0
72,0
86,0
86,0
104,0
104,0
125,0
141,0
141,0
175,0
200,0
217,0
217,0
230,0
230,0
271,0
300,0
343,0
343,0
355,0
375,0
375,0
420,0
440,0
485,0
485,0
500,0
534,0
550,0
650,0
668,0
701,0
755,0
755,0
770,0
810,0
936,0
920,0
1100,0
1180,0
1294,0
1644,0
70,0
90,0
90,0
109,0
109,0
131,0
131,0
157,0
184,0
184,0
216,0
259,0
275,0
300,0
309,0
309,0
345,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16


Part no.
10106
10107
10185
10108
10109
10110
10535
10111
10112
10536
10113
10114
10115
10116
10117
10187
10118
10119
10120
10121
10122
10123
10124
10125
10126
10127
10128
10129
10130
10131
10132
10133
10134
10135
10136
10137
10138
10139
10140
10141
10142
10143
10144
10145
10146
10147
10148
10149
10150
10151
10152
10153
10154
10190
10155
10156
10157
10191
10158
10159
10160
10192
10161
10162
10193
10163
10188
10194
10164
10189
10195
10165
10333
10166
13139
13140

No.cores x
cross-sec.
mm
16G1,5
18G1,5
19G1,5
20G1,5
21G1,5
25G1,5
27G1,5
32G1,5
34G1,5
37G1,5
41G1,5
42G1,5
50G1,5
56G1,5
61G1,5
65G1,5
80G1,5
100G1,5
2x2,5
3G2,5
3x2,5
4G2,5
4x2,5
5G2,5
5x2,5
7G2,5
7x2,5
8G2,5
12G2,5
14G2,5
18G2,5
21G2,5
25G2,5
34G2,5
42G2,5
50G2,5
61G2,5
100G2,5
2x4
3G4
4G4
5G4
7G4
8G4
12G4
3G6
4G6
5G6
7G6
3G10
4G10
5G10
7G10
3G16
4G16
5G16
7G16
3G25
4G25
5G25
7G25
3G35
4G35
5G35
3G50
4G50
5G50
3G70
4G70
5G70
3G95
4G95
5G95
4G120
4G150
4G185

Outer
Cop.
approx. mm weight
kg/km
13,9
230,0
14,6
259,0
15,2
279,0
15,5
288,0
15,5
302,0
17,4
360,0
19,0
389,0
19,5
461,0
20,2
490,0
20,2
533,0
21,8
591,0
21,8
605,0
24,2
720,0
24,9
806,0
25,8
878,0
26,7
936,0
29,8
1152,0
33,2
1440,0
7,8
48,0
8,3
72,0
8,3
72,0
9,2
96,0
9,2
96,0
10,1
120,0
10,1
120,0
11,2
168,0
11,2
168,0
12,3
192,0
14,8
288,0
16,0
336,0
18,2
432,0
19,1
504,0
21,6
600,0
25,0
816,0
27,2
1008,0
30,0
1200,0
32,0
1464,0
41,4
2400,0
9,3
77,0
9,8
115,0
11,0
154,0
12,3
192,0
13,6
269,0
14,6
307,0
17,8
461,0
11,9
173,0
13,0
230,0
14,5
288,0
16,2
403,0
14,8
288,0
16,4
384,0
18,3
480,0
20,2
672,0
18,2
461,0
20,0
614,0
22,6
768,0
24,8
1075,0
22,2
720,0
24,9
960,0
27,7
1200,0
30,6
1680,0
25,6
1008,0
28,4
1344,0
31,7
1680,0
30,9
1440,0
34,2
1920,0
38,3
2400,0
36,5
2016,0
40,3
2688,0
45,3
3360,0
41,1
2736,0
45,8
3648,0
52,7
4560,0
51,4
4608,0
58,5
5760,0
61,1
7104,0

Weight
approx.
kg/km
386,0
440,0
445,0
490,0
555,0
620,0
670,0
790,0
830,0
892,0
996,0
1007,0
1250,0
1332,0
1440,0
1602,0
1871,0
2353,0
112,0
148,0
148,0
178,0
178,0
221,0
221,0
306,0
306,0
363,0
498,0
569,0
764,0
914,0
1044,0
1470,0
1790,0
2095,0
2750,0
4450,0
195,0
230,0
295,0
361,0
458,0
590,0
790,0
355,0
424,0
525,0
625,0
540,0
701,0
858,0
1106,0
827,0
1035,0
1259,0
1780,0
1186,0
1582,0
1999,0
2825,0
1585,0
2105,0
2633,0
2550,0
2940,0
2936,0
3180,0
4090,0
5443,0
4680,0
5540,0
6931,0
7000,0
8340,0
9904,0

AWG-No.
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
12
12
12
12
12
12
12
10
10
10
10
8
8
8
8
6
6
6
6
4
4
4
4
2
2
2
1
1
1
2/0
2/0
2/0
3/0
3/0
3/0
4/0
300 kcmil
350 kcmil

Dimensions and specifications may be changed without prior notice. (RA01)

A7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-500 COLD

flexible at low temperature, number coded, meter marking

Technical data

Cable structure

Properties

Control cables, special PVC


Requirements adapted to DIN VDE0281,
0293, 0295
Temperature range
flexing -30 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors,


according to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Core insulation of special PVC YI4
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-lenght
Cold flexible outer sheath of special PVC
colour black (RAL9005)
with meter marking


Extensively oil resistant, l-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).

Application
This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without
forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport
belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses.
Selected PVC mixtures guarantee good flexibility, efficient and fast installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
10750
10751
10752
10753
10754
10755
10756
10757
10758
10759
10760
10761
10762
10763
10764
10765
10766
10767
10768
10769
10770
10771
10772
10773

No.cores x
cross-sec.
mm
2x0,5
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
7G0,75
7x0,75
12G0,75
18G0,75
25G0,75
2x1
3G1
3x1
4G1
4x1
5G1
5x1
7G1
7x1
12G1
18G1
25G1

Outer
Cop.
approx. mm weight
kg/km
4,9
9,6
5,6
21,6
5,6
21,6
6,3
28,8
6,3
29,0
6,9
36,0
6,9
36,0
7,5
50,0
7,5
50,0
9,8
86,0
12,2
130,0
14,3
180,0
5,6
19,2
5,9
29,0
5,9
29,0
6,6
38,4
6,6
38,4
7,3
48,0
7,3
48,0
8,1
67,0
8,1
67,0
10,4
115,0
12,9
173,0
15,4
240,0

Weight
approx.
kg/km
40,0
54,0
54,0
66,0
66,0
80,0
80,0
110,0
110,0
179,0
257,0
365,0
60,0
72,0
72,0
86,0
86,0
104,0
104,0
141,0
141,0
230,0
343,0
485,0

AWG-No.
20
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
17


Part no.
10774
10775
10776
10777
10778
10779
10780
10781
10782
10783
10784
10785
10786
10787
10788
10789
10790
10791
10792
10793
10794
10795
10796
10797

No.cores x
cross-sec.
mm
2x1,5
3G1,5
3x1,5
4G1,5
4x1,5
5G1,5
5x1,5
6G1,5
7G1,5
7x1,5
12G1,5
18G1,5
25G1,5
2x2,5
3G2,5
3x2,5
4G2,5
4x2,5
5G2,5
5x2,5
7G2,5
7x2,5
4G6
5G6

Outer
Cop.
approx. mm weight
kg/km
6,4
29,0
6,8
43,0
6,8
43,0
7,4
58,0
7,4
58,0
8,3
72,0
8,3
72,0
9,2
86,0
9,2
101,0
9,2
101,0
12,0
173,0
14,6
259,0
17,4
360,0
7,8
48,0
8,3
72,0
8,3
72,0
9,2
96,0
9,2
96,0
10,1
120,0
10,1
120,0
11,2
168,0
11,2
168,0
13,0
230,0
14,5
288,0

Weight
approx.
kg/km
70,0
90,0
90,0
109,0
109,0
131,0
131,0
157,0
184,0
184,0
309,0
440,0
620,0
112,0
148,0
148,0
178,0
178,0
221,0
221,0
306,0
306,0
424,0
525,0

AWG-No.
16
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14
14
10
10

Dimensions and specifications may be changed without prior notice. (RA01)

A8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-500 black flexible, meter marking




Technical data

Cable structure

Properties

Control cables, special PVC


adapted to DIN VDE 0281, 0293, 0295
Temperature range
flexing -15 C1) to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
1) cold bending test, impact resistance test
at low temperatures, elongation test at low
temperatures. Tested according VDE0473
part811-1-4, EN60811-1-4

Bare copper, fine wire conductors,


according to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Core insulation of special PVC Z 7225
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-lenght
Outer sheath of special PVC, TM2 to
DINVDE0281 part1 and HD21.1
colour black (RAL9005)
with meter marking

Extensively oil resistant, oil-/ chemical


Resistance- see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
UV- resistant


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
screened analogue type:
JZ-500-C black, see pageA24

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms and in open air. Must not be laid directly in soil or water.When screened for measurement, control and control
line etc. in mechanical and plant engineering, machine tools, production lines and conveyor belts.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
10340
10341
10342
10343
10344
10345
10346
10347
10348
10349
10350
10351
10352
10353
10354
10355
10356
10357
10358
10359
10360
10361
10362
10363

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75
2x1
3G1
4G1
5G1
7G1
12G1
18G1
25G1

Outer
Cop.
approx. mm weight
kg/km
5,5
9,6
5,8
14,4
6,2
19,0
6,9
24,0
7,5
33,6
9,8
58,0
11,8
86,0
13,7
120,0
5,9
14,4
6,2
21,6
6,7
28,8
7,5
36,0
8,3
50,0
10,8
86,0
12,8
130,0
15,1
180,0
6,2
19,2
6,5
29,0
7,2
38,4
7,9
48,0
8,7
67,0
11,4
115,0
13,7
173,0
16,2
240,0

Weight
approx.
kg/km
40,0
46,0
56,0
65,0
80,0
135,0
196,0
270,0
46,0
54,0
66,0
80,0
110,0
179,0
257,0
365,0
60,0
72,0
86,0
104,0
141,0
230,0
343,0
485,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20


Part no.
10364
10365
10366
10367
10368
10369
10370
10371
10372
10373
10374
10375
10376
10377
10378
10379
10380
10381
10382
10383
10384
10385
10386
10387

No.cores x
cross-sec.
mm
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5
4G4
5G4
4G6
5G6
4G10
4G16
4G25
4G35

Outer
Cop.
approx. mm weight
kg/km
7,0
29,0
7,4
43,0
8,2
58,0
9,1
72,0
9,8
101,0
13,6
173,0
15,6
259,0
18,4
360,0
8,4
48,0
8,9
72,0
9,8
96,0
10,9
120,0
12,0
168,0
15,9
288,0
19,0
432,0
22,6
600,0
11,6
154,0
12,9
192,0
13,1
230,0
14,5
288,0
17,0
384,0
20,9
614,0
25,6
960,0
30,0
1344,0

Weight
approx.
kg/km
70,0
90,0
109,0
131,0
184,0
309,0
440,0
620,0
112,0
148,0
178,0
221,0
306,0
498,0
764,0
1044,0
295,0
361,0
424,0
525,0
701,0
1035,0
1582,0
2105,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

Dimensions and specifications may be changed without prior notice. (RA01)

A9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-500 orange

flexible, orange cores, control cable for interlocking

purposes, meter marking

Technical data

Cable structure

Properties

Special PVC control cable for interlocking


purposes
Requirements adapted to DINVDE 0281,
0293, 0295
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors,to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of special PVC Z7225
Cores orange with continuous black
numbering according to DINVDE0293
JZ-version with green-yellow earth core: 3
cores and above
OZ-version without green-yellow earth core
Special PVC outer sheath TM2, to
DINVDE0281 part1 and HD21.1
Colour orange (RAL 2003)
with meter marking, change-over in 2011


Extensively oil resistant, oil-/ Chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air, as control cable according EN60204 part1 and VDE0113 part1.
As per recommendation of the specified standards the insulated conductors of control current circuits should be coloured orange, when
they are used for interlocking purposes. These control circuits are supplied with an external power and remain active under current when
the main switch is disconnected or switched off.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
10537
10538
10539
10541
10540
10542
10544
10545

No.cores x
cross-sec.
mm
2x1
3G1
3x1
4x1
4G1
5G1
2x1,5
3G1,5

Outer
Cop.
approx. mm weight
kg/km
5,6
19,2
5,9
29,0
5,9
29,0
6,6
38,4
6,6
38,4
7,3
48,0
6,4
29,0
6,8
43,0

Weight
approx.
kg/km
60,0
72,0
72,0
86,0
86,0
104,0
70,0
90,0

AWG-No.
17
17
17
17
17
17
16
16


Part no.
10546
10547
10747
10748
10749

No.cores x
cross-sec.
mm
4G1,5
5G1,5
3G2,5
4G2,5
5G2,5

Outer
Cop.
approx. mm weight
kg/km
7,4
58,0
8,3
72,0
8,3
72,0
9,2
96,0
10,1
120,0

Weight
approx.
kg/km
109,0
131,0
148,0
178,0
221,0

AWG-No.
16
16
14
14
14

Dimensions and specifications may be changed without prior notice. (RA01)

A 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H05VV5-F (NYSLY-JZ) flexible, number coded, oil resistant,


meter marking


Technical data

Cable structure

Properties

Control cable, special PVC with oil resistant


outer jacket to DINVDE0281 part13,
HD21.13S1 and IEC60227/75
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage U0/U 300/500 V
Test voltage 2000 V, 5 min.
Breakdown voltage min. 4000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire stranded conductor


to DINVDE0295 cl.5, BS6360 cl.5, HD383
and IEC60228 cl.5
Special PVC core insulation TI2 to
DINVDE0281 part1
Black cores with white figure imprint to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC outer jacket, TM5 to
DINVDE0281 part1, HD21.1.S4/A16
Colour grey (RAL 7001)
with meter marking, change-over in 2011

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Oil resistant toDIN EN60811-2-1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Application

Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
H05VVC4V5-K (NYSLYCY-JZ),
see pageA29

These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries,
conveyor belts and production lines.
These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling
plants and car washing stations.
These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
13122
13001
13002
13003
13004
13005
13920
13006
13921
13007
13922
13008
13009
13923
13010
13924
13125
13011
13012
13925

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
6G0,5
7G0,5
8G0,5
9G0,5
10G0,5
12G0,5
14G0,5
18G0,5
25G0,5
27G0,5
34G0,5
36G0,5
41G0,5
50G0,5
61G0,5
65G0,5

Outer
Cop.
min. - max. weight
mm
kg/km
5,2 - 6,6
9,7
5,5 - 7,0
14,4
6,2 - 7,9
19,0
6,8 - 8,6
24,0
7,6 - 9,6
29,0
8,3 - 10,4
33,6
8,9 - 10,8
38,0
9,7 - 12,1
43,0
10,0 - 12,2
48,0
10,4 - 12,9
58,0
10,8 - 13,2
67,0
12,3 - 15,3
86,0
15,1 - 18,8
120,0
15,1 - 18,6
129,6
16,8 - 20,8
163,0
17,0 - 20,9
172,0
18,3 - 22,4
196,0
20,3 - 25,3
240,0
21,8 - 27,0
293,0
24,3 - 29,8
312,0

Weight
approx.
kg/km
46,0
54,0
65,0
80,0
104,0
119,0
134,0
136,0
166,0
186,0
215,0
251,0
349,0
373,0
480,0
510,0
570,0
658,0
780,0
810,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20


Part no.
13123
13013
13014
13015
13016
13017
13926
13018
13019
13927
13020
13021
13928
13022
13929
13126
13023
13024
13930

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
6G0,75
7G0,75
8G0,75
9G0,75
12G0,75
14G0,75
18G0,75
25G0,75
27G0,75
34G0,75
36G0,75
41G0,75
50G0,75
61G0,75
65G0,75

Outer
Cop.
min. - max. weight
mm
kg/km
5,7 - 7,2
14,1
6,0 - 7,6
21,6
6,6 - 8,3
29,0
7,4 - 9,3
36,0
8,1 - 10,1
43,0
9,0 - 11,3
50,0
10,0 - 12,2
58,0
10,7 - 13,4
65,0
11,0 - 13,7
86,0
11,9 - 14,6
101,0
13,2 - 16,4
130,0
16,0 - 19,9
180,0
16,2 - 19,9
195,0
18,0 - 22,3
245,0
18,2 - 22,4
259,0
19,7 - 24,1
295,0
21,9 - 27,1
360,0
24,3 - 30,2
439,0
25,8 - 31,7
468,0

Weight
approx.
kg/km
52,0
68,0
82,0
107,0
132,0
145,0
189,0
194,0
231,0
274,0
313,0
461,0
493,0
614,0
646,0
730,0
896,0
1030,0
1071,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18

Continuation

A 11
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H05VV5-F (NYSLY-JZ) flexible, number coded, oil resistant,


meter marking

Part no.
13119
13025
13026
13027
13028
13029
13931
13030
13031
13932
13032
13933
13033
13934
13034
13124
13935
13127
13035
13036
13936
13120
13037
13038
13039
13040
13041
13937
13042
13043
13121
13044
13938
13045
13939
13046
13047
13940
13941
13128
13048
13049
13942

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
6G1
7G1
8G1
9G1
12G1
14G1
18G1
19G1
25G1
27G1
34G1
36G1
37G1
41G1
50G1
61G1
65G1
2x1,5
3G1,5
4G1,5
5G1,5
6G1,5
7G1,5
8G1,5
9G1,5
12G1,5
14G1,5
18G1,5
19G1,5
25G1,5
27G1,5
32G1,5
34G1,5
36G1,5
37G1,5
41G1,5
50G1,5
61G1,5
65G1,5

Outer
Cop.
min. - max. weight
mm
kg/km
5,9 - 7,5
19,0
6,3 - 8,0
29,0
6,9 - 8,7
38,0
7,8 - 9,8
48,0
8,7 - 10,8
58,0
9,5 - 11,8
67,0
10,5 - 12,9
77,0
11,3 - 14,0
86,0
11,8 - 14,6
115,0
12,7 - 15,6
134,0
14,0 - 17,2
173,0
14,3 - 17,6
183,0
16,8 - 20,6
240,0
17,0 - 21,0
259,0
19,2 - 23,6
326,0
19,4 - 23,8
348,0
19,8 - 24,5
355,0
20,8 - 25,5
392,0
22,9 - 28,0
480,0
24,3 - 29,8
586,0
26,5 - 32,7
624,0
6,8 - 8,6
29,0
7,4 - 9,4
43,0
8,2 - 10,2
58,0
9,1 - 11,4
72,0
10,2 - 12,6
86,0
11,3 - 14,1
101,0
12,5 - 15,4
115,0
12,9 - 16,1
130,0
13,8 - 17,0
173,0
14,3 - 18,0
202,0
16,5 - 20,3
259,0
16,2 - 20,0
274,0
20,8 - 25,6
360,0
20,3 - 24,9
389,0
21,4 - 26,4
461,0
23,1 - 28,4
490,0
23,0 - 28,2
518,0
23,0 - 28,2
532,0
24,3 - 29,8
590,0
27,7 - 34,1
720,0
29,6 - 36,3
878,0
30,4 - 37,2
963,0

Weight
approx.
kg/km
66,0
78,0
104,0
123,0
152,0
183,0
220,0
230,0
269,0
361,0
400,0
413,0
546,0
582,0
724,0
775,0
785,0
822,0
1052,0
1265,0
1315,0
77,0
97,0
128,0
149,0
196,0
216,0
271,0
282,0
324,0
372,0
485,0
495,0
671,0
695,0
820,0
881,0
905,0
920,0
1085,0
1381,0
1640,0
1730,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16


Part no.
13943
13050
13051
13052
13053
13945
13054
13946
13055
13056
13947
13057
13948
13949
13058
13059

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
8G2,5
12G2,5
14G2,5
18G2,5
25G2,5
27G2,5
34G2,5
36G2,5
41G2,5
50G2,5
61G2,5

Outer
Cop.
min. - max. weight
mm
kg/km
8,4 - 10,6
48,0
9,2 - 11,4
72,0
10,1 - 12,5
96,0
11,2 - 13,9
120,0
13,6 - 16,8
168,0
14,9 - 18,7
192,0
16,8 - 20,6
288,0
17,5 - 22,1
336,0
20,2 - 24,8
432,0
24,6 - 30,2
600,0
24,7 - 30,2
648,0
27,9 - 34,1
816,0
28,0 - 34,2
864,0
30,3 - 36,9
984,0
33,0 - 40,5
1200,0
35,0 - 42,9
1464,0

Weight
approx.
kg/km
110,0
154,0
212,0
242,0
350,0
379,0
543,0
611,0
787,0
1175,0
1280,0
1529,0
1791,0
1905,0
2290,0
2724,0

AWG-No.
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14

Dimensions and specifications may be changed without prior notice. (RA01)

A 12
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

(H)05VV5-F ((N)YSLY-JZ)

flexible, number coded, oil

resistant, meter marking




Technical data

Cable structure

Properties

Control cable, special PVC with oil resistant


outer jacket adapted to VDE0281 part13,
HD21.13S1 and IEC60227/75 deviation of
conductor cross sections.
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage U0/U 300/500 V
Test voltage 2000 V, 5 min
Breakdown voltage min. 4000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire stranded conductor


to DINVDE0295 cl.5, BS6360 cl.5,
IEC60228 cl.5 and HD383
Special PVC core insulation TI2 to
DINVDE0281 part1
Black cores with white figure imprint to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC outer jacket, TM5 to
DINVDE0281 part1, HD21.1.S4/A16
Colour grey (RAL7001)
with meter marking, change-over in 2011

PVC self-extinguishing and flame retardant


according to DINVDE0482 part265-2-1/
EN50265-2-1/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Oil resistant toDIN EN60811-2-1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
(H)05VVC4V5-K, see pageA31

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries,
conveyor belts and production lines.
These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling
plants and car washing stations.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
13133
13134
13135
13136
13138
13141
13142
13143
13144
13145
13146
13148
13149
13150
13151

No.cores x
cross-sec.
mm
2x4
3G4
4G4
5G4
7G4
12G4
2x6
3G6
4G6
5G6
7G6
3G10
4G10
5G10
7G10

Outer
Cop.
approx. mm weight
kg/km
10,7
77,0
11,3
115,0
12,4
154,0
13,9
192,0
16,6
269,0
20,8
461,0
12,0
116,0
12,9
173,0
14,2
230,0
15,9
288,0
18,9
403,0
16,3
288,0
18,1
384,0
20,3
480,0
24,3
672,0

Weight
approx.
kg/km
195,0
230,0
295,0
361,0
466,0
810,0
280,0
358,0
424,0
525,0
625,0
540,0
701,0
858,0
1106,0

AWG-No.
12
12
12
12
12
12
10
10
10
10
10
8
8
8
8


Part no.
13153
13154
13155
13156
13159
13160
13161
13162
13163
13164
13165
13166

No.cores x
cross-sec.
mm
3G16
4G16
5G16
7G16
4G25
5G25
3G35
4G35
5G35
3G50
4G50
5G50

Outer
Cop.
approx. mm weight
kg/km
18,8
461,0
20,9
614,0
23,4
768,0
28,5
1075,0
26,3
960,0
29,5
1200,0
26,5
1008,0
29,5
1344,0
32,8
1680,0
32,2
1440,0
36,1
1920,0
40,3
2400,0

Weight
approx.
kg/km
827,0
1035,0
1259,0
1780,0
1582,0
1852,0
1614,0
2110,0
2652,0
2560,0
2972,0
3948,0

AWG-No.
6
6
6
6
4
4
2
2
2
1
1
1

Dimensions and specifications may be changed without prior notice. (RA01)

A 13
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-750

flexible, number coded, 750V, meter marking

Technical data

Cable structure

Properties

Special PVC control cable


Requirements adapted to DINVDE0281
part13 and IEC60227/7
identical with H05VV-F to VDE0281 part13
and IEC60227/7 type227 IEC75, but
without increased oil resistant outer sheath
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 450/750 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors,to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special PVC core insulation TI2, to
DINVDE0281 part1
Black cores with white figure imprints to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC, outer sheath TM2, to
DINVDE0281 part1
Colour grey (RAL 7001)
With meter marking, change-over in 2011

Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
when ordering.

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air, wherever internationally recognized PVC cables are required. E.g. as a control or
measurements cable on industrial machinery, on conveyor systems or in industrial plants, etc. The number coding has been brought onto
the cores in such a way that it is easily identifiable and the core numbers are individually underlined to avoid confusion. The green-yellow
earth core is laid in the outer layer.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
10800
10801
10802
10803
10804
10805
10806
10807
10808
10809
10810
10811
10812
10813
10814
10815
10816
10817
10818
10819
10820
10821
10822
10823
10824
10825
10826
10827
10828
10829
10830
10831
10832
10833

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
8G0,5
10G0,5
12G0,5
14G0,5
16G0,5
18G0,5
21G0,5
25G0,5
30G0,5
40G0,5
50G0,5
61G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
8G0,75
10G0,75
12G0,75
15G0,75
18G0,75
21G0,75
25G0,75
34G0,75
41G0,75
50G0,75
61G0,75
2x1

Outer
Cop.
approx. mm weight
kg/km
5,7
9,6
6,0
14,5
6,8
20,0
7,4
24,0
8,3
34,0
9,1
38,0
10,0
48,0
10,8
58,0
11,7
67,0
12,5
76,0
13,2
87,0
13,8
96,0
15,5
118,0
16,6
144,0
18,7
192,0
21,5
240,0
23,0
293,0
6,2
15,0
6,5
22,0
7,3
29,0
8,0
36,0
8,9
51,0
9,6
58,0
10,7
72,0
11,6
87,0
13,2
108,0
14,1
130,0
14,8
151,0
16,6
180,0
19,3
245,0
20,9
296,0
22,9
360,0
24,5
440,0
6,6
20,0

Weight
approx.
kg/km
48,0
65,0
81,0
98,0
123,0
155,0
180,0
208,0
248,0
260,0
285,0
375,0
400,0
475,0
590,0
710,0
880,0
60,0
78,0
104,0
116,0
148,0
160,0
195,0
248,0
295,0
346,0
395,0
505,0
684,0
780,0
940,0
1125,0
80,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
17


Part no.
10834
10835
10836
10837
10838
10839
10840
10841
10842
10843
10844
10845
10846
10847
10848
10849
10850
10851
10852
10853
10854
10855
10856
10857
10858
10859
10860
10861
10862
10863
10864
10865
10866
10867

No.cores x
cross-sec.
mm
3G1
3x1
4G1
4x1
5G1
7G1
7x1
8G1
12G1
14G1
16G1
18G1
21G1
25G1
34G1
41G1
50G1
61G1
2x1,5
3G1,5
3x1,5
4G1,5
4x1,5
5G1,5
7G1,5
8G1,5
9G1,5
12G1,5
14G1,5
16G1,5
18G1,5
21G1,5
25G1,5
32G1,5

Outer
Cop.
approx. mm weight
kg/km
7,0
29,0
7,0
29,0
7,8
39,0
7,8
39,0
8,6
48,0
9,5
68,0
9,5
68,0
10,3
77,0
12,7
116,0
13,4
134,0
14,4
154,0
15,1
173,0
16,1
205,0
18,0
240,0
20,9
326,0
22,6
394,0
24,8
480,0
26,5
586,0
7,2
29,0
7,8
43,0
7,8
43,0
8,5
58,0
8,5
58,0
9,6
72,0
10,4
101,0
11,4
115,0
12,5
130,0
14,1
173,0
14,9
202,0
16,0
230,0
17,0
259,0
18,0
302,0
20,2
360,0
22,6
461,0

Weight
approx.
kg/km
92,0
92,0
122,0
122,0
137,0
186,0
186,0
240,0
293,0
340,0
400,0
437,0
505,0
606,0
770,0
880,0
1400,0
1450,0
90,0
120,0
120,0
150,0
155,0
177,0
220,0
248,0
278,0
364,0
390,0
490,0
550,0
670,0
745,0
810,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

Continuation

A 14
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-750

flexible, number coded, 750V, meter marking

Part no.
10868
10869
10870
10871
10872
10873
10874
10875

No.cores x
cross-sec.
mm
34G1,5
42G1,5
50G1,5
61G1,5
2x2,5
3G2,5
4G2,5
5G2,5

Outer
Cop.
approx. mm weight
kg/km
23,4
490,0
25,5
605,0
27,9
720,0
30,0
878,0
8,6
48,0
9,3
72,0
10,2
96,0
11,4
120,0

Weight
approx.
kg/km
1010,0
1115,0
1430,0
1750,0
110,0
190,0
240,0
270,0

AWG-No.
16
16
16
16
14
14
14
14


Part no.
10876
10877
10878
10879
10880

No.cores x
cross-sec.
mm
7G2,5
12G2,5
14G2,5
18G2,5
25G2,5

Outer
Cop.
approx. mm weight
kg/km
12,6
168,0
16,9
288,0
18,2
336,0
20,4
432,0
24,4
600,0

Weight
approx.
kg/km
350,0
600,0
870,0
1050,0
1170,0

AWG-No.
14
14
14
14
14

Dimensions and specifications may be changed without prior notice. (RA01)

Cable Glands
Cable glands for standard applications
Plastic Glands
Cable Glands of Brass
Accessories
Cable glands for special application conditions
for electromagnetic compatibility EMC
for rugged applications and special chemical resistance
for high temperature use
for explosive areas
for special mounting conditions
for special pressure conditions

You can nd cable glands in our catalogue Cable Accessories.

A 15
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-600 flexible, number coded, 0,6/1kV, meter marking




Technical data

Cable structure

Properties

Inaccordanceto DIN VDE 0262/12.95 and


DIN VDE 0281 part 13, with insulation
wallthickness for 1 kV
Temperature range
flexing -15 C1) to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Current carrying capacity
in accordance to VDE 0298 part 4
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
1) cold bending test, impact resistance test
at low temperatures, elongation test at low
temperatures. Tested according VDE0473
part811-1-4, EN60811-1-4

Bare copper, fine wire conductors,as per


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special PVC core insulation TI2, to
DINVDE0281 part1
Black cores with white figure imprints to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC outer sheath TM2, to
DINVDE0281 part1
Colour black (RAL 9005)
with meter marking, change-over in 2011


Extensively oil resistant, oil-/chemical


resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
UV- resistant


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
Different dimensions are also available with
red resp. blue cores.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
JZ-600-Y-CY see pageA36

Application
Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air
conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with
free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable
to be used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable,
even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located
in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and
Arabian countries.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
10550
10551
10552
10553
10554
10555
10556
10557
10558
10559
10560
10561
10562
10563
10564
10565
10566
10567
10568
10569
10570
10571
10572
10573
10574
10575
10576
10577
10578
10579
10580
10581

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4G0,5
4x0,5
5G0,5
5x0,5
6G0,5
7G0,5
7x0,5
8G0,5
8x0,5
10G0,5
12G0,5
12x0,5
14G0,5
16G0,5
18G0,5
20G0,5
21G0,5
25G0,5
30G0,5
32G0,5
34G0,5
40G0,5
42G0,5
50G0,5
52G0,5
61G0,5
65G0,5
80G0,5
100G0,5

Outer
Cop.
approx. mm weight
kg/km
6,3
9,6
6,6
14,4
6,6
14,4
7,2
19,0
7,2
19,0
8,0
24,0
8,0
24,0
8,7
29,0
8,7
33,6
8,7
33,6
9,5
38,0
9,5
38,0
10,6
48,0
11,4
58,0
11,4
58,0
12,3
67,0
12,9
76,0
13,8
86,0
14,4
96,0
14,4
96,0
16,1
120,0
17,2
144,0
18,0
154,0
18,7
163,0
19,5
192,0
20,1
202,0
22,1
240,0
22,1
252,0
23,6
293,0
24,4
312,0
27,2
384,0
31,2
480,0

Weight
approx.
kg/km
56,0
68,0
68,0
100,0
100,0
117,0
117,0
126,0
138,0
138,0
150,0
150,0
176,0
200,0
200,0
230,0
250,0
276,0
293,0
305,0
335,0
348,0
355,0
520,0
590,0
595,0
715,0
740,0
840,0
880,0
960,0
1050,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20


Part no.
10582
10583
10584
10585
10586
10587
10588
10589
10590
10591
10592
10593
10594
10595
10596
10597
10598
10599
10600
10601
10602
10603
10604
10605
10606
10607
10608
10609
10610
10611
10612
10613
10614
10615

No.cores x
cross-sec.
mm
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
6G0,75
6x0,75
7G0,75
7x0,75
8G0,75
8x0,75
9G0,75
10G0,75
12G0,75
12x0,75
14G0,75
15G0,75
18G0,75
20G0,75
21G0,75
25G0,75
32G0,75
34G0,75
37G0,75
40G0,75
41G0,75
42G0,75
50G0,75
61G0,75
65G0,75
80G0,75
100G0,75

Outer
Cop.
approx. mm weight
kg/km
6,6
14,4
6,9
21,6
6,9
21,6
7,5
29,0
7,5
29,0
8,4
36,0
8,4
36,0
9,3
43,0
9,3
43,0
9,3
50,0
9,3
50,0
10,0
58,0
10,0
58,0
10,9
65,0
11,1
72,0
12,2
86,0
12,2
86,0
12,9
101,0
13,8
108,0
14,5
130,0
15,4
144,0
15,4
151,0
17,2
180,0
19,0
230,0
19,9
245,0
19,9
260,0
20,6
288,0
20,6
296,0
21,5
302,0
23,7
360,0
25,3
439,0
26,0
468,0
28,9
576,0
33,2
720,0

Weight
approx.
kg/km
66,0
74,0
74,0
126,0
126,0
140,0
140,0
170,0
170,0
190,0
190,0
212,0
212,0
227,0
238,0
257,0
257,0
286,0
319,0
362,0
394,0
422,0
486,0
595,0
638,0
696,0
726,0
750,0
770,0
895,0
1070,0
1110,0
1500,0
1889,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18

Continuation

A 16
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-600 flexible, number coded, 0,6/1kV, meter marking




Part no.
10616
10617
10618
10619
10620
10621
10622
10623
10624
10625
10626
10627
10628
10629
10630
10631
10632
10633
10634
10635
10636
10637
10638
10639
10640
10641
10642
10643
10644
10645
10646
10647
10648
10649
10650
10651
10652
10653
10654
10655
10656
10657
10658
10659
10660
10661
10662
10663
10664
10665
10666
10667
10668
10669
10670
10671
10672
10673
10674
10675
10676
10677
10678
10679
10680
10681
10682
10683
10684
10685
10686
10687
10688
10689

No.cores x
cross-sec.
mm
2x1
3G1
3x1
4G1
4x1
5G1
5x1
6G1
7G1
7x1
8G1
9G1
10G1
10x1
12G1
12x1
14G1
16G1
18G1
18x1
20G1
20G1
21G1
24G1
25G1
25x1
26G1
30x1
34G1
36G1
40G1
40x1
41G1
42G1
50G1
56G1
61G1
65G1
80G1
100G1
2x1,5
3G1,5
3x1,5
4G1,5
4x1,5
5G1,5
5x1,5
6G1,5
7G1,5
7x1,5
8G1,5
9G1,5
10G1,5
11G1,5
12G1,5
12x1,5
14G1,5
16G1,5
18G1,5
19G1,5
20G1,5
21G1,5
25G1,5
32G1,5
34G1,5
40G1,5
42G1,5
50G1,5
56G1,5
61G1,5
65G1,5
80G1,5
100G1,5
2x2,5

Outer
Cop.
approx. mm weight
kg/km
7,0
19,2
7,4
29,0
7,4
29,0
8,2
38,4
8,2
38,4
9,2
48,0
9,2
48,0
9,9
58,0
9,9
67,0
9,9
67,0
10,9
77,0
11,6
86,0
11,9
96,0
11,9
96,0
13,1
115,0
13,1
115,0
14,0
134,0
14,8
154,0
15,7
173,0
15,7
173,0
16,7
192,0
16,7
192,0
16,7
205,0
18,4
236,0
18,6
240,0
18,6
240,0
18,8
252,0
19,8
308,0
21,5
326,0
21,5
346,0
22,5
384,0
22,5
384,0
23,2
394,0
23,2
403,0
25,6
480,0
26,4
538,0
27,3
586,0
28,3
628,0
31,4
786,0
36,0
960,0
8,2
29,0
8,6
43,0
8,6
43,0
9,6
58,0
9,6
58,0
10,7
72,0
10,7
72,0
11,6
86,0
11,6
101,0
11,6
101,0
13,8
115,0
15,2
130,0
15,2
144,0
15,5
158,0
15,5
173,0
15,5
173,0
16,6
202,0
17,5
230,0
18,6
259,0
18,6
279,0
19,7
288,0
20,6
302,0
22,5
360,0
24,5
461,0
25,6
490,0
26,7
576,0
27,6
605,0
30,4
720,0
31,5
806,0
32,6
878,0
34,8
936,0
37,4
1152,0
41,6
1440,0
9,6
48,0

Weight
approx.
kg/km
80,0
96,0
96,0
100,0
100,0
130,0
130,0
150,0
170,0
170,0
230,0
250,0
270,0
270,0
290,0
290,0
320,0
360,0
405,0
405,0
450,0
480,0
510,0
550,0
570,0
570,0
590,0
650,0
750,0
790,0
850,0
850,0
890,0
900,0
1100,0
1190,0
1266,0
1560,0
1810,0
1950,0
95,0
112,0
112,0
139,0
139,0
170,0
170,0
190,0
225,0
225,0
250,0
280,0
300,0
330,0
370,0
370,0
400,0
450,0
520,0
550,0
600,0
600,0
730,0
880,0
950,0
990,0
1120,0
1400,0
1530,0
1700,0
1900,0
2300,0
2700,0
160,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
14


Part no.
10690
10691
10692
10693
10694
10695
10696
10697
10698
10699
10700
10701
10702
10703
10704
10705
10706
10707
10708
10709
10710
10711
10712
10713
10714
10715
10716
10717
10718
10719
10720
10721
10722
10723
10724
10725
10726
10727
10728
10729
10730
10731
10732
10733
10734
10735
10736
10742
10737
10738
10743
10739
10740
10744
10741
10745
10746

No.cores x
cross-sec.
mm
3G2,5
3x2,5
4G2,5
4x2,5
5G2,5
5x2,5
7G2,5
7x2,5
8G2,5
12G2,5
14G2,5
18G2,5
21G2,5
25G2,5
34G2,5
42G2,5
50G2,5
61G2,5
100G2,5
2x4
3G4
4G4
5G4
7G4
8G4
12G4
3G6
4G6
5G6
7G6
3G10
4G10
5G10
7G10
3G16
4G16
5G16
7G16
3G25
4G25
5G25
7G25
3G35
4G35
5G35
3G50
4G50
5G50
3G70
4G70
5G70
3G95
4G95
5G95
4G120
4G150
4G185

Outer
Cop.
approx. mm weight
kg/km
10,1
72,0
10,1
72,0
11,2
96,0
11,2
96,0
12,5
120,0
12,5
120,0
13,8
168,0
13,8
168,0
15,1
192,0
18,3
288,0
19,6
336,0
22,0
432,0
23,3
504,0
26,2
600,0
30,4
816,0
33,0
1008,0
36,2
1200,0
38,8
1464,0
50,2
2400,0
11,1
77,0
11,7
115,0
13,0
154,0
14,5
192,0
16,0
269,0
17,4
307,0
21,4
461,0
13,1
173,0
14,5
230,0
16,2
288,0
18,0
403,0
16,5
288,0
18,2
384,0
20,3
480,0
22,5
672,0
20,1
461,0
22,3
614,0
25,0
768,0
27,4
1075,0
24,8
720,0
27,4
960,0
30,5
1200,0
33,8
1680,0
27,1
1008,0
30,0
1344,0
33,3
1680,0
32,4
1440,0
35,8
1920,0
40,0
2400,0
36,9
2016,0
40,9
2688,0
45,5
3360,0
41,7
2736,0
46,2
3648,0
51,7
4560,0
51,6
4608,0
58,5
5760,0
61,1
7104,0

Weight
approx.
kg/km
175,0
175,0
203,0
203,0
251,0
251,0
330,0
330,0
400,0
553,0
630,0
795,0
930,0
1110,0
1450,0
1750,0
2100,0
2540,0
3850,0
180,0
230,0
310,0
410,0
540,0
710,0
860,0
370,0
430,0
650,0
860,0
660,0
790,0
960,0
1300,0
700,0
1100,0
1600,0
1890,0
1450,0
1600,0
2050,0
2900,0
1900,0
2400,0
2900,0
2700,0
3400,0
4361,0
3300,0
4400,0
5807,0
5050,0
6010,0
7752,0
7500,0
8640,0
10380,0

AWG-No.
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
12
12
12
12
12
12
12
10
10
10
10
8
8
8
8
6
6
6
6
4
4
4
4
2
2
2
1
1
1
2/0
2/0
2/0
3/0
3/0
3/0
4/0
300 kcmil
350 kcmil

Dimensions and specifications may be changed without prior notice. (RA01)

A 17
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H03VV-F

according to DIN VDE 0281

Technical data

Cable structure

Properties

PVC-control cables to DINVDE0281 part5


and IEC60227-5, HD21.5 S3
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage U0/U 300/300 V
Max. permissible operating voltage
in three-phase and one-phase
a.c. system U0/U 330/330 V
in direct current system
U0/U 495/495 V
Test voltage 2000 V
Breakdown voltage
min. 4000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5, IEC60228 cl.5 and HD383
PVC core insulation TI2 to
DINVDE0281part1
Cores colour coded to DINVDE0293-308
6 and more cores number coded
1x green-yellow earth core incl.
Green-yellow earth-core, 3 cores and above
Cores stranded in layers with optimal
lay-length
PVC outer jacket in black, white or as per
requirement
PVC outer jacket TM2 to DINVDE0281
part1

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
5 core and above in adaption (H).
The above list contains a selection of the
types we carry es stock.
Other sizes available on request.

Application
These cable types are especially suited to use on small appliances with low mechanical stress and for connection for light household appliances,
e.g. kitchen utensils, desk lamps, floor lamps, vacuum cleaners, office machines, radios, etc., as far as this cable is admitted to the relevant
specifications of the equipment.
These cables are not permitted to use with cooking or heating apparatus.
Cables with cross-section 0,75 mm are not suitable for outdoor use or use of industrial or farmer machineries.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
29736
2x0,5
29737
2x0,5
29738
2x0,5
29739
3G0,5
29740
3G0,5
29741
3G0,5
29742
4G0,5
29743
4G0,5
29744
4G0,5
29400
2x0,75
29401
2x0,75
29402
2x0,75
29403
3G0,75
29404
3G0,75
29405
3G0,75

Jacket
colour
black
white
other colours
black
white
other colours
black
white
other colours
black
white
other colours
black
white
other colours

Outer
Cop.
Weight AWG-No.
min. - max. weight approx.
mm
kg/km kg/km
4,6 - 5,9
9,6
40,0
20
4,6 - 5,9
9,6
40,0
20
4,6 - 5,9
9,6
40,0
20
5,0 - 6,4
14,4
49,0
20
5,0 - 6,4
14,4
49,0
20
5,0 - 6,4
14,4
49,0
20
5,4 - 7,0
19,2
61,0
20
5,4 - 7,0
19,2
61,0
20
5,4 - 7,0
19,2
61,0
20
4,9 - 6,3
14,4
49,0
18
4,9 - 6,3
14,4
49,0
18
4,9 - 6,3
14,4
49,0
18
5,2 - 6,7
21,6
59,0
18
5,2 - 6,7
21,6
59,0
18
5,2 - 6,7
21,6
59,0
18


Part no. No.cores x
cross-sec.
mm
29406
4G0,75
29407
4G0,75
29408
4G0,75
29409
5G0,75
29410
5G0,75
29411
5G0,75
29412
6G0,75
29413
6G0,75
29414
6G0,75
29415
7G0,75
29416
7G0,75
29417
7G0,75

Jacket
colour
black
white
other colours
black
white
other colours
black
white
other colours
black
white
other colours

Outer
Cop.
Weight AWG-No.
min. - max. weight approx.
mm
kg/km kg/km
5,7 - 7,3
29,0
72,0
18
5,7 - 7,3
29,0
72,0
18
5,7 - 7,3
29,0
72,0
18
6,4 - 8,2
36,0
87,0
18
6,4 - 8,2
36,0
87,0
18
6,4 - 8,2
36,0
87,0
18
7,1 - 9,0
43,0
98,0
18
7,1 - 9,0
43,0
98,0
18
7,1 - 9,0
43,0
98,0
18
7,1 - 9,0
50,0
108,0
18
7,1 - 9,0
50,0
108,0
18
7,1 - 9,0
50,0
108,0
18

Dimensions and specifications may be changed without prior notice. (RA01)

A 18
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H05VV-F

according to DIN VDE 0281

Technical data

Cable structure

Properties

PVC-control cables to DINVDE0281 part5


and IEC60227-5, HD21.5S3
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage
U0/U 300/500 V
Max. permissible operating voltage
in three-phase and one-phase
a.c. system U0/U 318/550 V
in direct current system
U0/U 413/825 V
Test voltage 2000 V
Breakdown voltage
min. 4000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5, IEC60228 cl.5 and HD383
PVC core insulation TI2 to
DINVDE0281part1
Cores colour coded to DINVDE0293-308
1x green-yellow earth core incl.
Green-yellow earth core, 3 cores and above
Cores stranded in layers with optimal
lay-length
PVC outer jacket in white or black
PVC outer jacket TM2 to DINVDE0281
part1

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
These types are also available with
UL-approbation.
The above list contains a selection of the
tyoes we carry es stock.
Other sizes available on request.
Cables with 7 cores are only availbale as
"A"-type.
6 mm in adaption (H).

Application
These cables are especially suited to use for the appliance with medium mechanical stress in households, kitchens and offices, also for
household appliances in damp and wet areas, e.g. refrigerators, washing machines, spin-driver etc. As far as this cable is admitted to the
relevant specifications of the equipment.
These cables are suited to be used for cooking and heating apparatus under the condition that cable does not come in direct contact with
hot parts of the apparatus and no other influences of heat.
The cables are suitable for fixed installation in furnitures, partition walls, decoration covering and in hollow spaces of prefabricated building
parts.
They are not qualified for use in outdoors or for use with industrial and farmer machineries, exceptionally in tailoring, etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.cores x


cross-sec.
mm
29450
2x0,75
29451
2x0,75
29452
3G0,75
29453
3G0,75
29454
4G0,75
29455
4G0,75
29456
5G0,75
29457
5G0,75
29458
2x1
29459
2x1
29460
3G1
29461
3G1
29462
4G1
29463
4G1
29464
5G1
29465
5G1
29466
7G1
29467
7G1
29484
2x1,5
29485
2x1,5
29468
3G1,5
29469
3G1,5
29470
4G1,5
29471
4G1,5
29472
5G1,5
29473
5G1,5

Jacket
colour
black
white
black
white
black
white
black
white
black
white
black
white
black
white
black
white
black
white
black
white
black
white
black
white
black
white

Outer
Cop.
Weight AWG-No.
min. - max. weight approx.
mm
kg/km kg/km
5,7 - 7,2
14,4
50,0
18
5,7 - 7,2
14,4
50,0
18
6,0 - 7,6
21,6
60,0
18
6,0 - 7,6
21,6
60,0
18
6,6 - 8,3
29,0
73,0
18
6,6 - 8,3
29,0
73,0
18
7,4 - 9,3
36,0
88,0
18
7,4 - 9,3
36,0
88,0
18
5,9 - 7,5
19,0
57,0
17
5,9 - 7,5
19,0
57,0
17
6,3 - 8,0
29,0
73,0
17
6,3 - 8,0
29,0
73,0
17
7,1 - 9,0
38,0
85,0
17
7,1 - 9,0
38,0
85,0
17
7,8 - 9,8
48,0
105,0
17
7,8 - 9,8
48,0
105,0
17
9,3 - 12,0
67,0
131,0
17
9,3 - 12,0
67,0
131,0
17
6,8 - 8,6
29,0
82,0
16
6,8 - 8,6
29,0
82,0
16
7,4 - 9,4
43,0
95,0
16
7,4 - 9,4
43,0
95,0
16
8,4 - 10,5
58,0
117,0
16
8,4 - 10,5
58,0
117,0
16
9,3 - 11,6
72,0
144,0
16
9,3 - 11,6
72,0
144,0
16


Part no. No.cores x
cross-sec.
mm
29474
7G1,5
29475
7G1,5
29478
3G2,5
29479
3G2,5
29480
4G2,5
29481
4G2,5
29482
5G2,5
29483
5G2,5
29486
7G2,5
29487
7G2,5
29825
3G4
29826
3G4
29488
4G4
29489
4G4
29490
5G4
29491
5G4
29492
4G6
29493
4G6

Jacket
colour
black
white
black
white
black
white
black
white
black
white
black
white
black
white
black
white
black
white

Outer
Cop.
Weight AWG-No.
min. - max. weight approx.
mm
kg/km kg/km
10,8 - 13,5
101,0
183,0
16
10,8 - 13,5
101,0
183,0
16
9,2 - 11,4
72,0
152,0
14
9,2 - 11,4
72,0
152,0
14
10,1 - 12,5
96,0
192,0
14
10,1 - 12,5
96,0
192,0
14
11,2 - 13,9
120,0
243,0
14
11,2 - 13,9
120,0
243,0
14
13,0 - 17,0
168,0
316,0
14
13,0 - 17,0
168,0
316,0
14
10,5 - 13,1
115,0
235,0
12
10,5 - 13,1
115,0
235,0
12
11,5 - 14,3
154,0
300,0
12
11,5 - 14,3
154,0
300,0
12
13,0 - 16,1
192,0
361,0
12
13,0 - 16,1
192,0
361,0
12
13,2 - 16,3
230,0
490,0
10
13,2 - 16,3
230,0
490,0
10

Dimensions and specifications may be changed without prior notice. (RA01)

A 19
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H05VV-F

according to DIN VDE 0281

Technical data

Cable structure

Properties

PVC-control cables to DINVDE0281 part5


and IEC60227-5, HD21.5S3
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage U0/U 300/500 V
Max. permissible operating voltage
in three-phase and one-phase
a.c. system U0/U 318/550 V
in direct current system
U0/U 413/825 V
Test voltage 2000 V
Breakdown voltage
min. 4000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5, IEC60228 cl.5 and HD383
PVC core insulation TI2 to DINVDE0281
part1
Cores colour coded to DINVDE0293-308
Green-yellow earth core, 3 cores and above
Cores stranded in layers with optimal
lay-length
PVC outer jacket TM2 to DINVDE0281
part1
Jacket colour in accordance to the
customer


PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Colour code:
0 = blue (approx. RAL 5015)
1 = green (approx. RAL 6018)
2 = brown (approx. RAL 8003)
3 = yellow (approx. RAL 1021)
4 = red (approx. RAL 3000)
5 = orange (approx. RAL 2003)
6 = violet (approx. RAL 4005)
7 = grey (approx. RAL 7001/7032)
8 = gold
9 = dusty gold
Please add the individual part no. for order
with the identification colour code.
Further colours on request.

Application
These cable are especially suited to use for the appliance with medium mechanical stress in households, kitchens and offices, also for
household appliances in damp and wet areas, e.g. refrigerators, washing machines, spin-driver etc. As far as this cable is admitted to the
relevant specifications of the equipment.
These cables are suited to be used for cooking and heating apparatus under the condition that cable does not come in direct contact with
hot parts of the apparatus and no other influences of heat.
The cables are suitable for fixed installation in furnitures, partition walls, decoration covering and in hollow spaces of prefabricated building
parts.
They are not qualified for use in outdoors or for use with industrial and farmer machineries, exceptionally in tailoring, etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
3011_
3012_
3013_
3014_
3015_
3016_
3017_
3018_

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
2x1
3G1
4G1
5G1

Outer
Cop.
min. - max. weight
mm
kg/km
5,7 - 7,2
14,4
6,0 - 7,6
21,6
6,6 - 8,3
29,0
7,4 - 9,3
36,0
5,9 - 7,5
19,0
6,3 - 8,0
29,0
7,1 - 9,0
38,0
7,8 - 9,8
48,0

Weight
approx.
kg/km
50,0
60,0
73,0
88,0
57,0
73,0
85,0
105,0

AWG-No.
18
18
18
18
17
17
17
17


Part no.
3020_
3021_
3022_
3023_
3024_
3025_
3026_

No.cores x
cross-sec.
mm
2x1,5
3G1,5
4G1,5
5G1,5
3G2,5
4G2,5
5G2,5

Outer
Cop.
min. - max. weight
mm
kg/km
6,8 - 8,6
29,0
7,4 - 9,4
43,0
8,4 - 10,5
58,0
9,3 - 11,6
72,0
9,2 - 11,4
72,0
10,1 - 12,5
96,0
11,2 - 13,9
120,0

Weight
approx.
kg/km
82,0
95,0
117,0
144,0
152,0
192,0
243,0

AWG-No.
16
16
16
16
14
14
14

Dimensions and specifications may be changed without prior notice. (RA01)

A 20
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JB-500

flexible, colour coded, meter marking

Technical data

Cable structure

Properties

In accordanceto DINVDE0281, 0293, 0295


Temperature range
flexing -15 C1) to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
1) cold bending test, impact resistance test
at low temperatures, elongation test at low
temperatures. Tested according VDE0473
Teil811-1-4, EN60811-1-4

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of special PVC Z7225
Cores colour coded as per JB/OB colour
code
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC outer sheath TM2, to
DINVDE0281 part1
Colour grey (RAL 7001)
with meter marking, change-over in 2011
from 5 cores with VDE-Reg-Nr.

Extensively oil resistant, oil-/chemical


resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OB).
screened analogue type:
Y-CY-JB, see page A 38

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air, as measuring and control cables in tool machinery, conveyor belts, production lines,
as well as in machinery production, in air-conditioning and steel production plants. The earth core is located immediately below the outer
jacket. JB cables are suitable for use in all electrical equipment either in dry or damp areas. They should not, however, be installed in the
open air.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
11001
11002
11003
11004
11005
11006
11007
11008
11009
11010
11011
11012
11013
11014
11015
11019
11026
11027
11028
11029
11030
11031
11032
11033
11034
11035
11036
11037
11038
11039
11040
11041
11042
11043
11050
11051
11052
11053
11054
11055
11056

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4G0,5
4x0,5
5G0,5
5x0,5
6G0,5
7G0,5
7x0,5
8G0,5
10G0,5
12G0,5
14G0,5
16G0,5
30G0,5
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
6G0,75
7G0,75
7x0,75
8G0,75
9G0,75
10G0,75
12G0,75
15G0,75
18G0,75
21G0,75
25G0,75
2x1
3G1
3x1
4G1
4x1
5G1
5x1

Outer
Cop.
approx. mm weight
kg/km
4,9
9,6
5,2
14,4
5,2
14,4
5,6
19,2
5,6
19,2
6,3
24,0
6,3
24,0
6,9
29,0
6,9
34,0
6,9
34,0
7,4
38,0
8,3
48,0
8,8
58,0
9,7
67,0
10,2
77,0
13,8
144,0
5,3
14,4
5,6
21,6
5,6
21,6
6,3
28,8
6,3
28,8
6,9
36,0
6,9
36,0
7,5
43,2
7,5
50,0
7,5
50,0
8,2
58,0
8,8
65,0
9,2
72,0
9,8
86,0
11,2
108,0
12,2
130,0
12,7
151,0
14,3
180,0
5,6
19,2
5,9
29,0
5,9
29,0
6,6
38,4
6,6
38,4
7,3
48,0
7,3
48,0

Weight
approx.
kg/km
40,0
46,0
46,0
56,0
56,0
65,0
65,0
75,0
80,0
84,0
97,0
116,0
135,0
150,0
172,0
310,0
46,0
54,0
54,0
66,0
66,0
80,0
80,0
99,0
110,0
110,0
130,0
153,0
162,0
179,0
218,0
257,0
320,0
365,0
60,0
72,0
72,0
86,0
86,0
104,0
104,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17


Part no.
11057
11058
11059
11060
11061
11062
11063
11064
11065
11066
11067
11068
11069
11070
11077
11078
11079
11080
11081
11082
11083
11084
11085
11086
11087
11088
11089
11090
11091
11092
11093
11094
11104
11105
11106
11107
11108
11109
11110
11111
11112

No.cores x
cross-sec.
mm
6G1
6x1
7G1
7x1
8G1
9G1
10G1
12G1
14G1
16G1
18G1
20G1
24G1
25G1
2x1,5
3G1,5
3x1,5
4G1,5
4x1,5
5G1,5
5x1,5
6G1,5
7G1,5
7x1,5
8G1,5
11G1,5
12G1,5
14G1,5
16G1,5
18G1,5
20G1,5
25G1,5
2x2,5
3G2,5
3x2,5
4G2,5
4x2,5
5G2,5
5x2,5
6G2,5
7G2,5

Outer
Cop.
approx. mm weight
kg/km
8,1
58,0
8,1
58,0
8,1
67,0
8,1
67,0
8,7
77,0
9,8
87,0
9,8
96,0
10,4
115,0
11,4
134,0
12,3
154,0
12,9
173,0
13,7
192,0
14,7
230,0
15,4
240,0
6,4
29,0
6,8
43,0
6,8
43,0
7,4
58,0
7,4
58,0
8,3
72,0
8,3
72,0
9,2
86,4
9,2
101,0
9,2
101,0
9,9
115,0
12,0
158,0
12,0
173,0
13,0
202,0
13,9
230,0
14,6
259,0
15,5
288,0
17,4
360,0
7,8
48,0
8,3
72,0
8,3
72,0
9,2
96,0
9,2
96,0
10,1
120,0
10,1
120,0
11,2
144,0
11,2
168,0

Weight
approx.
kg/km
125,0
125,0
141,0
141,0
175,0
200,0
207,0
230,0
271,0
300,0
343,0
375,0
468,0
485,0
70,0
90,0
90,0
109,0
109,0
131,0
131,0
157,0
184,0
184,0
216,0
300,0
309,0
345,0
386,0
440,0
490,0
620,0
112,0
148,0
148,0
178,0
178,0
221,0
221,0
293,0
306,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14
14

Dimensions and specifications may be changed without prior notice. (RA01)

A 21
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JB-750 flexible, colour coded, 750V, meter marking




Technical data

Cable structure

Properties

Special PVC control cables


Requirements adapted to DINVDE0281,
0293, 0295 and IEC60227-5
to H05VV-F VDE0281 part5 and
IEC60227-5 Type60227 IEC57
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 450/750 V
fixed installation, under protection
U0/U 600/1000 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special PVC core insulation TI2, to
DINVDE0281 part1
Cores colour coded as per JB/OB colour
code
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC outer sheath TM2, to
DINVDE0281 part1
Colour grey (RAL 7001)
with meter marking, change-over in 2011


Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to DINVDE0482 part265-2-1/
EN50265-2-1/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers



Note

G = with green-yellow earth core;


x = without green-yellow earth core (OB).
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
when ordering.
screened analogue type:
Y-CY-JB, see pageA38


Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air, as measuring and control cables in tool machinery, conveyor belts, production lines,
as well as in machinery production, in air-conditioning and steel production plants. The earth core is located immediately below the outer
jacket. JB cables are suitable for use in all electrical equipment either in dry or damp areas. They should not, however, be installed in the
open air.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
11161
11162
11163
11164
11165
11166
11167
11168
11169
11121
11144
11122
11123
11124
11125
11126
11127
11128
11129
11153
11130
11131
11132
11154
11133
11134
11135

No.cores x
cross-sec.
mm
2x2,5
3G2,5
3x2,5
4G2,5
4x2,5
5G2,5
5x2,5
6G2,5
7G2,5
2x4
3G4
4G4
5G4
7G4
11G4
3G6
4G6
5G6
7G6
3G10
4G10
5G10
7G10
3G16
4G16
5G16
7G16

Outer
Cop.
approx. mm weight
kg/km
8,8
48,0
9,3
72,0
9,3
72,0
10,2
96,0
10,2
96,0
11,4
120,0
11,4
120,0
12,6
144,0
12,6
168,0
10,7
76,8
11,3
115,0
12,6
154,0
14,1
192,0
15,6
269,0
20,8
422,0
12,7
173,0
14,1
230,0
15,8
288,0
17,6
403,0
16,1
290,0
17,9
384,0
19,9
480,0
22,2
672,0
19,7
461,0
21,7
614,0
24,4
768,0
26,8
1075,0

Weight
approx.
kg/km
130,0
164,0
164,0
200,0
200,0
247,0
247,0
301,0
321,0
195,0
235,0
295,0
361,0
498,0
767,0
355,0
424,0
525,0
625,0
611,0
701,0
858,0
1106,0
912,0
1035,0
1259,0
1780,0

AWG-No.
14
14
14
14
14
14
14
14
14
12
12
12
12
12
12
10
10
10
10
8
8
8
8
6
6
6
6


Part no.
11155
11136
11137
11156
11138
11139
11157
11140
11145
11158
11141
11146
11159
11142
11147
11160
11143
11148
11149

No.cores x
cross-sec.
mm
3G25
4G25
5G25
3G35
4G35
5G35
3G50
4G50
5G50
3G70
4G70
5G70
3G95
4G95
5G95
3G120
4G120
4G150
4G185

Outer
Cop.
approx. mm weight
kg/km
24,4
720,0
26,8
960,0
29,9
1200,0
26,5
1008,0
29,4
1344,0
32,7
1680,0
31,8
1440,0
35,0
1920,0
39,2
2400,0
36,1
2016,0
39,9
2688,0
44,9
3360,0
40,9
2736,0
45,4
3648,0
50,7
4560,0
46,2
3456,0
51,6
4608,0
58,5
5760,0
61,1
7104,0

Weight
approx.
kg/km
1388,0
1581,0
1997,0
1767,0
2105,0
2636,0
2556,0
2940,0
3936,0
3182,0
4090,0
5443,0
4676,0
5540,0
6931,0
5630,0
7000,0
8340,0
9904,0

AWG-No.
4
4
4
2
2
2
1
1
1
2/0
2/0
2/0
3/0
3/0
3/0
4/0
4/0
300 kcmil
350 kcmil

Dimensions and specifications may be changed without prior notice. (RA01)

A 22
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JB-750 yellow

flexible, colour coded, 750V, connection cable for warning

indication, meter marking




Technical data

Cable structure

Properties

Special PVC as connection cable for warning


indication
Requirements adapted to 0281 part5,
HD21.5 and IEC60227/5 type227 IEC57
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 450/750 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special PVC core insulation TI2, to
DINVDE0281 part1
Cores colour coded to DINVDE0293
Green-yellow earth core: 3 cores and above
Cores stranded in layers with optimal
lay-length
Special PVC outer sheath TM2, to
DINVDE0281 part1
Colour yellow (RAL 1016)
with meter marking, change-over in 2011


Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core.


AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air, as connection cable with yellow outer sheath as a special warning indication.
Recommendation in adapted to EN60204 part1 and DINVDE0113 part1.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
10334
10335
10336

No.cores x
cross-sec.
mm
3G1,5
4G1,5
5G1,5

Outer
Cop.
approx. mm weight
kg/km
7,8
43,0
8,5
58,0
9,6
72,0

Weight
approx.
kg/km
100,0
121,0
148,0

AWG-No.
16
16
16


Part no.
10337
10338
10339

No.cores x
cross-sec.
mm
3G2,5
4G2,5
5G2,5

Outer
Cop.
approx. mm weight
kg/km
9,3
72,0
10,2
96,0
11,4
120,0

Weight
approx.
kg/km
154,0
208,0
229,0

AWG-No.
14
14
14

Dimensions and specifications may be changed without prior notice. (RA01)

A 23
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-500-C black EMC-preffered type, Cu-screened, flexible, meter marking




Technical data

Cable structure

Properties

Special PVC control cables, adapted to


DINVDE0245, 0281, 0293, 0295
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage
core/core 4000 V
core/screen 2000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Core insulation of special PVC Z7225
Black cores with continuous white figure
imprint to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Foil separator
Tinned copper braided screening, approx.
85% coverage
Special PVC outer sheath TM2, to special
PVC, TM2 to DINVDE0281 part1 and
HD21.1
Colourblack (RAL 9005)
with meter marking

Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
UV- resistant


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
unscreened analogue type:
JZ-500 black, see page A 9

Application
For medium mechanical stress for flexible use with free movement without tensile stress or forced movements in dry, damp, wet rooms
and in open air. Must not be laid directly in soil or water. When screened for measurement, control and control line etc. in mechanical and
plant engineering, machine tools, production lines and conveyor belts.
EMC = Electromagneticcompatibility
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
10934
10935
10936
10937
10938
10939
10940
10941
10942
10943
10944
10945
10946
10947
10948
10949
10950
10951
10952
10953
10954
10955
10956
10957

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75
2x1
3G1
4G1
5G1
7G1
12G1
18G1
25G1

Outer
Cop.
approx. mm weight
kg/km
6,1
35,0
6,4
42,0
6,8
47,0
7,5
56,0
8,1
69,0
10,4
108,0
12,6
145,0
14,5
240,0
6,5
40,0
6,8
52,0
7,3
60,0
8,1
71,0
8,9
91,0
11,6
142,0
13,6
212,0
15,9
281,0
6,8
50,0
7,1
60,0
7,8
71,0
8,5
88,0
9,3
111,0
12,2
184,0
14,5
260,0
17,0
349,0

Weight
approx.
kg/km
45,0
55,0
61,0
74,0
98,0
157,0
217,0
314,0
59,0
66,0
77,0
93,0
130,0
202,0
292,0
415,0
65,0
80,0
98,0
127,0
158,0
260,0
380,0
534,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20


Part no.
10958
10959
10960
10961
10962
10963
10964
10965
10966
10967
10968
10969
10970
10971
10972
10973
10974
10975
10976
10977
10978
10979
10980

No.cores x
cross-sec.
mm
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
4G4
5G4
4G6
5G6
4G10
4G16
4G25
4G35

Outer
Cop.
approx. mm weight
kg/km
7,6
63,0
8,0
80,0
8,8
97,0
9,7
119,0
10,4
147,0
13,8
267,0
16,4
374,0
19,2
526,0
9,0
96,0
9,5
144,0
10,4
148,0
11,7
181,0
12,8
255,0
16,7
441,0
19,8
570,0
12,4
230,0
13,7
273,0
13,9
305,0
15,3
439,0
17,8
535,0
23,3
740,0
28,4
1140,0
31,0
1576,0

Weight
approx.
kg/km
88,0
100,0
126,0
160,0
208,0
338,0
479,0
705,0
130,0
167,0
195,0
223,0
344,0
570,0
681,0
310,0
385,0
415,0
509,0
783,0
880,0
1570,0
2070,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

Dimensions and specifications may be changed without prior notice. (RA01)

A 24
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

F-CY-OZ (LiY-CY) flexible, Cu-screened, EMC-preferred type,


meter marking


Technical data

Cable structure

Properties

Special PVC data cables, adapted to


DINVDE0281 part13
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
for 1 core (LiYDY) 1200 V
Test voltage core/core 4000 V
core/screen 2000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Mutual capacitance according to
different cross-sections
core/core approx. 150 nF/km
core/screen approx. 270 nF/km
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)


Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Core insulation of special PVC Z7225
Black cores with continuous numbering in
white according to DINVDE0293
Cores stranded in layers with optimal
lay-length
Core wrapping with foil
Tinned copper braided screen, approx. 85%
coverage
For 1 core cable copper screen of helically
wound (type LiYDY), approx. 85% coverage
Special PVC outer sheath TM2,to
DINVDE0281 part1 and HD21.1
Sheath colour grey (RAL7001)
with meter marking, change-over in 2011

Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

x = without green-yellow earth core (OZ).


For 1 core cable screen of helically wound.
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
when ordering.
For more information, see introduction
unscreened analogue type:
JZ 500, see page A 6 

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air, as data cables in control technologies, in the tool making and machine industries,
in computers and as a signal cable for the electronics branch. A stabilizing separator between core bundle and braid reduces essentially the
external diameter and allows smaller bending radius, lower weight etc.
The dense screening assures disturbance-free transmission of all signals and impulses. An ideal disturbance-free control cable for the above
applications.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
16531
16532
16533
16534
16535
16536
16537
16538
16539
16540
16541
16542
16543

No.cores x
cross-sec.
mm
1x0,5
2x0,5
3x0,5
4x0,5
5x0,5
6x0,5
7x0,5
8x0,5
10x0,5
12x0,5
14x0,5
16x0,5
18x0,5

Outer
Cop.
approx. mm weight
kg/km
3,7
15,0
5,7
35,0
5,9
42,0
6,4
47,0
6,9
56,0
7,6
67,0
7,6
69,0
8,7
80,0
9,6
94,0
9,7
108,0
10,2
116,0
11,0
129,0
11,5
145,0

Weight
approx.
kg/km
41,0
45,0
55,0
61,0
74,0
89,0
98,0
117,0
135,0
157,0
190,0
210,0
217,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20


Part no.
16544
16545
16546
16547
16548
16549
16550
16551
16552
16553
16554
16555
16556

No.cores x
cross-sec.
mm
20x0,5
21x0,5
24x0,5
25x0,5
30x0,5
32x0,5
34x0,5
36x0,5
40x0,5
50x0,5
61x0,5
80x0,5
100x0,5

Outer
Cop.
approx. mm weight
kg/km
12,2
172,0
12,7
188,0
13,5
235,0
13,6
240,0
14,4
295,0
14,9
301,0
15,6
312,0
15,6
318,0
16,9
343,0
18,5
406,0
19,7
508,0
22,6
680,0
24,9
804,0

Weight
approx.
kg/km
240,0
250,0
300,0
314,0
360,0
425,0
433,0
446,0
475,0
573,0
653,0
784,0
995,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20

Continuation

A 25
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

F-CY-OZ (LiY-CY) flexible, Cu-screened, EMC-preferred type,


meter marking

Part no.
16557
16558
16559
16560
16561
16562
16563
16564
16565
16566
16567
16568
16569
16570
16571
16572
16573
16574
16575
16576
16577
16578
16579
16580
16581
16582
16583
16584
16585
16050
16051
16052
16053
16054
16055
16056
16057
16058
16059
16060
16061
16062
16063
16064
16065
16066
16067
16068
16069
16070
16071
16072
16073

No.cores x
cross-sec.
mm
1x0,75
2x0,75
3x0,75
4x0,75
5x0,75
6x0,75
7x0,75
8x0,75
10x0,75
12x0,75
14x0,75
16x0,75
18x0,75
19x0,75
20x0,75
21x0,75
24x0,75
25x0,75
27x0,75
30x0,75
32x0,75
34x0,75
36x0,75
37x0,75
40x0,75
50x0,75
61x0,75
80x0,75
100x0,75
1x1
2x1
3x1
4x1
5x1
6x1
7x1
8x1
10x1
12x1
14x1
16x1
18x1
20x1
24x1
25x1
28x1
30x1
34x1
40x1
50x1
61x1
80x1
100x1

Outer
Cop.
approx. mm weight
kg/km
4,0
19,0
6,1
40,0
6,3
52,0
6,8
60,0
7,4
71,0
8,2
80,0
8,2
91,0
9,6
110,0
10,3
137,0
10,5
142,0
11,3
180,0
11,9
200,0
12,7
212,0
12,7
230,0
13,3
238,0
14,0
246,0
14,9
270,0
15,0
281,0
15,0
304,0
15,8
320,0
16,7
342,0
17,2
345,0
17,2
350,0
17,2
361,0
18,6
369,0
20,3
461,0
21,7
540,0
24,8
711,0
27,6
900,0
4,6
21,0
6,4
50,0
6,7
60,0
7,2
71,0
8,0
88,0
8,7
97,0
8,7
111,0
10,1
127,0
11,2
150,0
11,4
184,0
12,0
196,0
12,8
209,0
13,5
260,0
14,3
317,0
16,0
320,0
16,2
349,0
17,0
408,0
17,0
441,0
18,5
486,0
19,9
510,0
21,8
625,0
23,3
702,0
26,6
920,0
29,7
1120,0

Weight
approx.
kg/km
44,0
59,0
66,0
77,0
93,0
113,0
130,0
145,0
180,0
202,0
225,0
275,0
292,0
308,0
320,0
378,0
435,0
415,0
435,0
450,0
484,0
502,0
535,0
592,0
610,0
777,0
900,0
1210,0
1445,0
47,0
65,0
81,0
98,0
127,0
144,0
158,0
197,0
232,0
260,0
302,0
345,0
380,0
440,0
495,0
534,0
595,0
616,0
741,0
835,0
1025,0
1200,0
1440,0
1610,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17


Part no.
16074
16075
16076
16077
16078
16079
16080
16081
16082
16083
16084
16085
16086
16087
16088
16089
16090
16091
16092
16093
16094
16095
16096
16097
16098
16099
16100
16101
16102
16103
16104
16105
16106
16107
16108
16109
16110
16111
16112
16113
16114
16115
16116
16117
16118

No.cores x
cross-sec.
mm
1x1,5
2x1,5
3x1,5
4x1,5
5x1,5
7x1,5
8x1,5
10x1,5
12x1,5
14x1,5
16x1,5
18x1,5
20x1,5
24x1,5
25x1,5
28x1,5
30x1,5
35x1,5
40x1,5
50x1,5
61x1,5
80x1,5
100x1,5
1x2,5
2x2,5
3x2,5
4x2,5
5x2,5
7x2,5
12x2,5
2x4
3x4
4x4
5x4
7x4
2x6
3x6
4x6
5x6
7x6
2x10
3x10
4x10
5x10
7x10

Outer
Cop.
approx. mm weight
kg/km
5,0
27,0
7,0
63,0
7,5
80,0
8,1
97,0
9,0
119,0
9,8
147,0
11,4
170,0
12,6
193,0
12,8
267,0
13,5
283,0
14,4
315,0
15,5
374,0
16,4
396,0
18,2
458,0
18,4
526,0
19,1
541,0
19,1
555,0
20,8
645,0
22,6
725,0
24,7
885,0
26,4
1100,0
30,3
1324,0
33,6
1641,0
5,8
39,0
8,3
96,0
9,0
144,0
9,8
148,0
10,9
181,0
11,9
255,0
15,8
441,0
9,8
120,0
10,6
174,0
11,5
230,0
12,7
273,0
14,0
316,0
11,7
173,0
12,5
240,0
13,8
305,0
15,3
439,0
16,9
505,0
14,7
255,0
15,7
350,0
17,3
535,0
19,2
592,0
21,4
810,0

Weight
approx.
kg/km
70,0
88,0
100,0
126,0
160,0
208,0
244,0
316,0
338,0
383,0
424,0
479,0
545,0
690,0
705,0
810,0
830,0
890,0
1060,0
1440,0
1700,0
2000,0
2500,0
50,0
130,0
167,0
195,0
223,0
344,0
522,0
185,0
240,0
310,0
400,0
500,0
268,0
330,0
415,0
509,0
672,0
425,0
500,0
783,0
856,0
1300,0

AWG-No.
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
12
12
12
12
12
10
10
10
10
10
8
8
8
8
8

Dimensions and specifications may be changed without prior notice. (RA01)

A 26
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

F-CY-JZ

flexible, Cu-screened, EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Special PVC control cables, adapted to


DINVDE0281 part13
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage
core/core 4000 V
core/screen 2000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Mutual capacitance according to
different cross-sections
0,5 mm to 2,5 mm:
core/core approx. 150 nF/km
core/screen approx. 270 nF/km
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Core insulation of special PVC Z7225
Black cores with continuous white figure
imprint to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Foil separator
Tinned copper braided screening, approx.
85% coverage
Special PVC outer sheath TM2, to special
PVC, TM2 to DINVDE0281 part1 and
HD21.1
Colour grey (RAL7001)
With meter marking, change-over in 2011

Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Please note the cleanroom qualification
when ordering.
To optimise the EMC features we
recommend a large round contact of the
copper braiding on both ends.
unscreened analogue type:
JZ-500, see pageA6

Application
For use as a data cable in control circuits, in tool-making and machine industries as well as a signal cable in computer systems and electronics.
The more usual PVC inner sheath has been replaced in these cables by a stabilising foil separator, thus reducing the total diameter of the
cables considerably and thereby reducing the bending radius, total weight etc. The high covering percentage of the copper screening offers
interference-free signal transfer etc.
The dense screening assures disturbance-free transmission of all signals and impulses. An ideal disturbance-free control cable for the above
application.
EMC = Electromagnetic compatibillity
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
16320
16321
16322
16323
16324
16325
16326
16327
16328
16329
16330
16331
16332

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
6G0,5
7G0,5
8G0,5
10G0,5
12G0,5
14G0,5
16G0,5
18G0,5
20G0,5

Outer
Cop.
approx. mm weight
kg/km
5,7
35,0
5,9
42,0
6,4
47,0
6,9
56,0
7,6
67,0
7,6
69,0
8,7
80,0
9,6
94,0
9,7
108,0
10,2
116,0
11,0
129,0
11,5
145,0
12,2
172,0

Weight
approx.
kg/km
45,0
55,0
61,0
74,0
89,0
98,0
117,0
135,0
157,0
190,0
210,0
217,0
240,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20


Part no.
16333
16334
16335
16336
16337
16165
16338
16339
16490
16340
16341
16342
16343

No.cores x
cross-sec.
mm
21G0,5
24G0,5
25G0,5
30G0,5
32G0,5
34G0,5
36G0,5
40G0,5
41G0,5
50G0,5
61G0,5
80G0,5
100G0,5

Outer
Cop.
approx. mm weight
kg/km
12,7
188,0
13,5
235,0
13,6
240,0
14,4
295,0
14,9
301,0
15,6
312,0
15,6
318,0
16,9
343,0
16,9
348,0
18,5
406,0
19,7
508,0
22,6
680,0
24,9
804,0

Weight
approx.
kg/km
250,0
300,0
314,0
360,0
425,0
433,0
446,0
475,0
486,0
573,0
653,0
784,0
995,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20

Continuation

A 27
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

F-CY-JZ

flexible, Cu-screened, EMC-preferred type, meter marking


Part no.
16344
16345
16346
16347
16348
16349
16350
16351
16353
16354
16355
16356
16447
16357
16358
16359
16360
16361
16362
16363
16166
16364
16448
16365
16491
16366
16367
16368
16369
16370
16371
16372
16373
16374
16375
16376
16377
16378
16379
16380
16381
16352
16382
16383
16384
16439
16385
16386
16387
16446
16388
16492
16389
16390
16391
16392

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
6G0,75
7G0,75
8G0,75
10G0,75
12G0,75
14G0,75
16G0,75
18G0,75
19G0,75
20G0,75
21G0,75
24G0,75
25G0,75
27G0,75
30G0,75
32G0,75
34G0,75
36G0,75
37G0,75
40G0,75
41G0,75
50G0,75
61G0,75
80G0,75
100G0,75
2x1
3G1
4G1
5G1
6G1
7G1
8G1
10G1
12G1
14G1
16G1
18G1
19G1
20G1
24G1
25G1
27G1
28G1
30G1
34G1
37G1
40G1
41G1
50G1
61G1
80G1
100G1

Outer
Cop.
approx. mm weight
kg/km
6,1
40,0
6,3
52,0
6,8
60,0
7,4
71,0
8,2
80,0
8,2
91,0
9,6
110,0
10,3
137,0
10,5
142,0
11,3
180,0
11,9
200,0
12,7
212,0
12,7
230,0
13,3
238,0
14,0
246,0
14,9
270,0
15,0
281,0
15,0
304,0
15,8
320,0
16,7
342,0
17,2
345,0
17,2
350,0
17,2
361,0
18,6
369,0
18,6
400,0
20,3
461,0
21,7
540,0
24,8
711,0
27,6
900,0
6,4
50,0
6,7
60,0
7,2
71,0
8,0
88,0
8,7
97,0
8,7
111,0
10,1
127,0
11,2
150,0
11,4
184,0
12,0
196,0
12,8
209,0
13,5
260,0
13,5
280,0
14,3
317,0
16,0
320,0
16,2
349,0
16,2
400,0
17,0
408,0
17,0
441,0
18,5
486,0
18,5
519,0
19,9
510,0
19,9
531,0
21,8
625,0
23,3
702,0
26,6
920,0
29,7
1120,0

Weight
approx.
kg/km
59,0
66,0
77,0
93,0
113,0
130,0
145,0
180,0
202,0
225,0
275,0
292,0
308,0
320,0
378,0
435,0
415,0
435,0
450,0
484,0
502,0
535,0
592,0
610,0
622,0
777,0
900,0
1210,0
1445,0
65,0
80,0
98,0
127,0
144,0
158,0
197,0
232,0
260,0
302,0
346,0
380,0
412,0
440,0
493,0
534,0
562,0
595,0
616,0
741,0
790,0
835,0
843,0
1025,0
1205,0
1445,0
1613,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17


Part no.
16393
16394
16395
16396
16397
16398
16399
16400
16401
16402
16403
16449
16404
16405
16406
16407
16450
16408
16409
16410
16451
16411
16493
16412
16413
16414
16415
16416
16417
16418
16419
16420
16421
16438
16452
16422
16423
16424
16425
16426
16427
16428
16429
16430
16431
16432
16433
16434
16435
16436
16440
16437
16441
16442
16443
16444
16445

No.cores x
cross-sec.
mm
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5
14G1,5
16G1,5
18G1,5
19G1,5
20G1,5
21G1,5
24G1,5
25G1,5
27G1,5
28G1,5
30G1,5
35G1,5
37G1,5
40G1,5
41G1,5
50G1,5
61G1,5
80G1,5
100G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
10G2,5
12G2,5
18G2,5
2x4
3G4
4G4
5G4
7G4
2x6
3G6
4G6
5G6
7G6
2x10
3G10
4G10
5G10
7G10
4G16
5G16
4G25
5G25
4G35
5G35
4G50

Outer
Cop.
approx. mm weight
kg/km
7,0
63,0
7,5
80,0
8,1
97,0
9,0
119,0
9,8
147,0
11,4
170,0
12,6
193,0
12,8
267,0
13,5
283,0
14,4
315,0
15,4
374,0
15,4
386,0
16,1
396,0
17,0
425,0
18,2
458,0
18,4
526,0
18,4
531,0
19,1
541,0
19,1
555,0
20,8
645,0
20,8
674,0
22,6
725,0
22,6
801,0
24,7
885,0
26,4
1100,0
30,3
1324,0
33,6
1641,0
8,3
96,0
9,0
144,0
9,8
148,0
10,9
181,0
11,9
255,0
15,5
340,0
15,8
441,0
18,9
570,0
9,8
120,0
10,6
174,0
11,5
230,0
12,7
273,0
14,0
316,0
11,7
173,0
12,5
240,0
13,8
305,0
15,3
439,0
16,9
505,0
14,7
255,0
15,7
350,0
17,3
535,0
19,2
592,0
21,4
810,0
20,4
740,0
22,6
895,0
24,9
1140,0
27,8
1380,0
28,4
1576,0
31,6
1930,0
34,6
2155,0

Weight
approx.
kg/km
88,0
100,0
126,0
160,0
208,0
244,0
315,0
338,0
383,0
424,0
479,0
508,0
545,0
560,0
690,0
705,0
774,0
810,0
830,0
890,0
945,0
1060,0
1071,0
1290,0
1705,0
2010,0
2505,0
130,0
167,0
195,0
223,0
344,0
460,0
570,0
681,0
185,0
240,0
310,0
385,0
500,0
268,0
330,0
415,0
509,0
672,0
425,0
500,0
783,0
856,0
1305,0
880,0
1295,0
1570,0
1965,0
2070,0
2690,0
3015,0

AWG-No.
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14
12
12
12
12
12
10
10
10
10
10
8
8
8
8
8
6
6
4
4
2
2
1

Dimensions and specifications may be changed without prior notice. (RA01)

Process control for a large cabling


machine at our Windsbach factory.

A 28
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H05VVC4V5-K (NYSLYCY-JZ)

flexible, number

coded, oil resistant, EMC-preferred type




Technical data

Cable structure

Properties

Control cable, special PVC with oil resistant


outer jacket to DINVDE0281 part13,
HD21.13S1 and IEC60227/74
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage U0/U 300/500 V
Test voltage
core/core 2 kV, 5 min
core/screen2 kV, 5 min
Breakdown voltage min. 4000 V
Insulation resistance
min. 20 MOhm x km
Coupling resistance
at 30 MHz 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire stranded conductor


to DINVDE0295 cl. 5, BS6360 cl.5, HD383
and IEC60228 cl.5
Special PVC core insulation TI2 to
DINVDE0281 part1
Black cores with white figure imprint to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC inner sheath, TM2 to
DINVDE0281 part1
Tinned copper braided screening, covering
approx. 85%
Special PVC outer jacket, TM5 to
DINVDE0281 part1, HD21.1.S4/A16
Colour grey (RAL7001)

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Oil resistant toDIN EN60811-2-1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
H05VV5-F (NYSLY-JZ), see pageA11

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries,
conveyor belts and production lines. These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially
used for machines in breweries, bottling plants and car washing stations.
These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement. The
interconnection of parts of machines used for manufacturing purposes including machine tools where some degree of protection against
electromagnetic interference is required.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
13951
13060
13061
13062
13063
13064
13952
13065
13066
13953
13067
13068
13954
13069
13955
13129
13070
13071
13956

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
6G0,5
7G0,5
8G0,5
9G0,5
12G0,5
14G0,5
18G0,5
25G0,5
27G0,5
34G0,5
36G0,5
41G0,5
50G0,5
61G0,5
65G0,5

Outer
Cop.
approx. mm weight
kg/km
8,0
41,0
8,4
45,0
9,1
54,0
10,1
66,0
10,7
73,0
11,4
79,0
12,5
82,0
12,5
94,0
13,5
137,0
14,2
142,0
15,8
156,0
18,6
250,0
18,6
255,0
20,8
316,0
20,8
320,0
23,0
348,0
25,0
407,0
26,8
520,0
28,4
563,0

Weight
approx.
kg/km
92,0
109,0
126,0
156,0
176,0
192,0
211,0
230,0
280,0
302,0
384,0
556,0
599,0
634,0
620,0
770,0
970,0
1072,0
1198,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20


Part no.
13957
13072
13073
13074
13075
13076
13958
13077
13078
13959
13079
13080
13960
13081
13961
13130
13082
13083
13962

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
6G0,75
7G0,75
8G0,75
9G0,75
12G0,75
14G0,75
18G0,75
25G0,75
27G0,75
34G0,75
36G0,75
41G0,75
50G0,75
61G0,75
65G0,75

Outer
Cop.
approx. mm weight
kg/km
8,3
46,0
8,8
57,0
9,8
63,0
10,8
76,0
11,4
82,0
12,1
100,0
12,7
112,0
13,8
130,0
14,3
175,0
14,4
190,0
16,9
240,0
20,0
306,0
20,0
326,0
22,1
346,0
22,1
358,0
23,9
403,0
26,8
470,0
29,4
550,0
31,2
594,0

Weight
approx.
kg/km
102,0
115,0
150,0
173,0
195,0
235,0
268,0
285,0
327,0
362,0
488,0
654,0
708,0
821,0
899,0
970,0
1160,0
1402,0
1504,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18

Continuation

A 29
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H05VVC4V5-K (NYSLYCY-JZ)
coded, oil resistant, EMC-preferred type

Part no.
13963
13084
13085
13086
13087
13088
13964
13089
13090
13965
13091
13966
13092
13967
13093
13968
13969
13131
13094
13095
13970
13971
13096
13097
13098
13099
13100
13972
13101
13102

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
6G1
7G1
8G1
9G1
12G1
14G1
18G1
19G1
25G1
27G1
34G1
36G1
37G1
41G1
50G1
61G1
65G1
2x1,5
3G1,5
4G1,5
5G1,5
6G1,5
7G1,5
8G1,5
9G1,5
12G1,5

Outer
Cop.
approx. mm weight
kg/km
8,6
54,0
9,3
64,0
10,2
76,0
11,0
89,0
11,8
101,0
12,9
114,0
13,6
130,0
14,4
144,0
15,6
186,0
15,7
198,0
17,4
284,0
17,4
307,0
21,1
387,0
21,9
410,0
24,1
500,0
23,8
511,0
25,1
523,0
26,0
578,0
28,5
681,0
30,1
710,0
32,4
769,0
9,1
64,0
10,2
82,0
10,9
99,0
11,6
123,0
12,4
125,0
13,5
148,0
15,6
172,0
15,6
187,0
16,8
274,0

Weight
approx.
kg/km
114,0
142,0
175,0
205,0
236,0
264,0
301,0
335,0
420,0
433,0
561,0
584,0
766,0
822,0
996,0
1001,0
1018,0
1155,0
1300,0
1500,0
1510,0
146,0
176,0
207,0
235,0
279,0
314,0
345,0
380,0
500,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16

flexible, number


Part no.
13973
13103
13974
13104
13975
13105
13106
13976
13977
13132
13107
13108
13978
13985
13109
13110
13111
13112
13979
13113
13980
13114
13115
13981
13116
13982
13983
13117
13118

No.cores x
cross-sec.
mm
14G1,5
18G1,5
19G1,5
25G1,5
27G1,5
32G1,5
34G1,5
36G1,5
37G1,5
41G1,5
50G1,5
61G1,5
65G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
8G2,5
12G2,5
14G2,5
18G2,5
25G2,5
27G2,5
34G2,5
36G2,5
41G2,5
50G2,5
61G2,5

Outer
Cop.
approx. mm weight
kg/km
18,3
294,0
20,0
386,0
20,4
394,0
24,2
531,0
24,6
546,0
26,0
638,0
26,3
671,0
27,7
700,0
27,7
720,0
29,1
840,0
34,0
997,0
36,5
1120,0
38,1
1197,0
11,4
110,0
11,7
148,0
12,8
169,0
13,9
220,0
15,9
284,0
18,7
314,0
20,6
470,0
22,5
504,0
24,3
572,0
29,0
740,0
29,8
971,0
33,0
1179,0
33,3
1268,0
36,0
1473,0
38,5
1660,0
42,0
1992,0

Weight
approx.
kg/km
560,0
707,0
723,0
950,0
1014,0
1133,0
1204,0
1261,0
1300,0
1453,0
1663,0
1852,0
1971,0
190,0
243,0
280,0
342,0
439,0
489,0
760,0
890,0
1052,0
1375,0
1507,0
1892,0
1998,0
2286,0
2673,0
3085,0

AWG-No.
16
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14

Dimensions and specifications may be changed without prior notice. (RA01)

A 30
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

(H)05VVC4V5-K ((N)YSLYCY-JZ)

number coded,

screened, oil resistant, EMC-preferred type




Technical data

Cable structure

Properties

Control cable, special PVC with oil resistant


outer jacket to DINVDE0281 part13,
HD21.13S1 and IEC60227/74
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage U0/U 300/500 V
Test voltage
core/core 2 kV, 5 min
core/screen 2 kV, 5 min
Breakdown voltage min. 4000 V
Insulation resistance
min. 20 MOhm x km
Coupling resistance
at 30 MHz 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire stranded conductor


to DINVDE0295 cl.5, BS6360 cl.5, HD383
and IEC60228 cl.5
Special PVC core insulation TI2 to
DINVDE0281 part1
Black cores with white figure imprint to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC inner sheath, TM2 to
DINVDE0281 part 1
Tinned copper braided screening, covering
approx. 85%
Special PVC outer jacket, TM5 to
DINVDE0281 part1, HD21.1.S4/A16
Colour grey (RAL7001)
with meter marking, change-over in 2011

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Oil resistant toDIN EN60811-2-1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
(H)05VV5-F ((N)YSLY-JZ), see pageA13

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries,
conveyor belts and production lines. These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially
used for machines in breweries, bottling plants and car washing stations.
These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.
The interconnection of parts of machines used for manufacturing purposes including machine tools where some degree of protection
against electromagnetic interference is required.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
13170
13171
13172
13173
13175
13178
13179
13180
13181
13182
13183
13185
13186
13187
13188

No.cores x
cross-sec.
mm
2x4
3G4
4G4
5G4
7G4
12G4
2x6
3G6
4G6
5G6
7G6
3G10
4G10
5G10
7G10

Outer
Cop.
approx. mm weight
kg/km
12,5
124,0
13,9
178,0
15,7
234,0
17,1
284,0
20,5
321,0
25,5
581,0
14,6
176,0
15,7
245,0
17,3
316,0
19,5
442,0
23,1
530,0
19,9
367,0
22,0
549,0
24,6
604,0
29,5
820,0

Weight
approx.
kg/km
236,0
361,0
430,0
509,0
660,0
979,0
296,0
420,0
579,0
719,0
1031,0
655,0
894,0
927,0
1518,0

AWG-No.
12
12
12
12
12
12
10
10
10
10
10
8
8
8
8


Part no.
13190
13191
13192
13193
13196
13197
13198
13199
13189
13194
13195
13184

No.cores x
cross-sec.
mm
3G16
4G16
5G16
7G16
4G25
5G25
3G35
4G35
5G35
3G50
4G50
5G50

Outer
Cop.
approx. mm weight
kg/km
22,9
653,0
25,5
807,0
27,9
940,0
33,9
1345,0
31,6
1169,0
35,1
1420,0
31,1
1250,0
34,4
1680,0
37,4
2020,0
36,9
1887,0
40,3
2370,0
44,9
2880,0

Weight
approx.
kg/km
993,0
1340,0
1626,0
2080,0
1692,0
1972,0
1704,0
2320,0
2780,0
2661,0
3194,0
4247,0

AWG-No.
6
6
6
6
4
4
2
2
2
1
1
1

Dimensions and specifications may be changed without prior notice. (RA01)

A 31
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Y-CY-JZ

flexible, CU-screened, transparent, EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Special PVC control cables, adapted to


DINVDE0281 part13
Temperature range
flexing -15 C1) to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Mutual capacitance according
to different cross-sections
0,5 mm to 2,5 mm:
core/core approx. 150 nF/km
core/screen approx. 270 nF/km
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
1) cold bending test, impact resistance test
at low temperatures, elongation test at low
temperatures. Tested according VDE0473
part811-1-4, EN60811-1-4

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Core insulation of special PVC Z7225
Black cores with continuous white
numbering to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC inner sheath
Tinned copper, braided screen, approx.
85% coverage
Transparent special PVC outer sheath
with meter marking, change-over in 2011

Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
unscreened analogue type:
JZ-500,see pageA6

Application
For use as a data and control cable in machinery, computer systems etc. as well as a signal cable for electronics. The high level of screening
ensures a high degree of interference protection. The screening density assures disturbancefree transmission of all signals and impulses.
The PVC-inner sheaths of those cables raise the mechanical stress. The applied clear transparent PVC outer sheath accentuates the optical
view of the tinned copper braid.
EMC = Electromagnetic compatibillity
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
16200
16169
16201
16202
16170
16203
16171
16204
16205
17172
16206
16207
16208
16209
16210
16211
16212
16315
16213
16214
16215
16216
16217
16218
16453

No.cores x
cross-sec.
mm
2x0,5
3x0,5
3G0,5
4G0,5
4x0,5
5G0,5
5x0,5
6G0,5
7G0,5
7x0,5
8G0,5
10G0,5
12G0,5
14G0,5
16G0,5
18G0,5
20G0,5
21G0,5
24G0,5
25G0,5
30G0,5
32G0,5
36G0,5
40G0,5
41G0,5

Outer
Cop.
approx. mm weight
kg/km
7,1
41,0
7,2
45,0
7,4
45,0
8,0
54,0
7,8
54,0
8,5
66,0
8,3
66,0
9,3
73,0
9,3
79,0
9,5
79,0
9,8
82,0
10,9
107,0
11,6
137,0
12,4
142,0
12,9
147,0
13,5
156,0
14,2
173,0
14,2
189,0
15,6
236,0
15,6
250,0
16,4
297,0
17,1
312,0
17,9
320,0
18,4
345,0
19,1
348,0

Weight
approx.
kg/km
67,0
83,0
83,0
94,0
94,0
108,0
108,0
125,0
136,0
136,0
150,0
170,0
195,0
223,0
250,0
277,0
310,0
331,0
390,0
407,0
520,0
550,0
585,0
654,0
671,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20


Part no.
16219
16220
16221
16222
16223
16224
16173
16225
16196
16226
16174
16227
16228
16175
16229
16230
16231
16232
16233
16234
16235
16316
16236
16237
16238
16239

No.cores x
cross-sec.
mm
50G0,5
61G0,5
80G0,5
100G0,5
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
6G0,75
7G0,75
7x0,75
8G0,75
10G0,75
12G0,75
14G0,75
16G0,75
18G0,75
20G0,75
21G0,75
24G0,75
25G0,75
27G0,75
30G0,75

Outer
Cop.
approx. mm weight
kg/km
20,9
407,0
22,4
520,0
25,2
690,0
28,4
805,0
7,7
46,0
8,0
57,0
7,8
57,0
8,5
63,0
8,3
63,0
9,3
76,0
9,1
76,0
9,9
82,0
10,1
100,0
10,4
100,0
10,6
112,0
11,7
140,0
12,7
175,0
13,3
190,0
14,1
204,0
14,9
240,0
15,4
262,0
15,4
274,0
17,3
291,0
17,3
306,0
17,7
326,0
18,5
340,0

Weight
approx.
kg/km
740,0
850,0
1080,0
1350,0
87,0
98,0
98,0
113,0
113,0
130,0
130,0
156,0
184,0
184,0
221,0
270,0
292,0
315,0
335,0
358,0
420,0
454,0
480,0
508,0
535,0
640,0

AWG-No.
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18

Continuation

A 32
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Y-CY-JZ

flexible, CU-screened, transparent, EMC-preferred type, meter marking

Part no.
16240
16241
16242
16454
16243
16244
16245
16246
16248
16249
16176
16250
16177
16251
16178
16252
16253
16179
16254
16255
16256
16257
16258
16259
16260
16261
16262
16263
16264
16265
16266
16455
16267
16268
16269
16270
16271
16272
16180
16273
16181
16274
16182
16275
16183
16276
16277
16278

No.cores x
cross-sec.
mm
32G0,75
36G0,75
40G0,75
41G0,75
50G0,75
61G0,75
80G0,75
100G0,75
2x1
3G1
3x1
4G1
4x1
5G1
5x1
6G1
7G1
7x1
8G1
10G1
12G1
14G1
16G1
18G1
20G1
24G1
25G1
28G1
30G1
34G1
40G1
41G1
50G1
61G1
80G1
100G1
2x1,5
3G1,5
3x1,5
4G1,5
4x1,5
5G1,5
5x1,5
7G1,5
7x1,5
8G1,5
10G1,5
12G1,5

Outer
Cop.
approx. mm weight
kg/km
19,1
349,0
19,9
358,0
20,6
371,0
21,2
403,0
23,2
470,0
25,0
550,0
28,3
715,0
31,6
910,0
8,0
54,0
8,3
64,0
8,2
64,0
9,0
76,0
8,9
76,0
9,7
89,0
9,5
89,0
10,3
101,0
10,5
114,0
11,0
114,0
11,2
130,0
12,5
156,0
13,3
186,0
14,1
198,0
14,8
214,0
15,6
284,0
16,3
325,0
18,2
366,0
18,4
387,0
19,2
421,0
19,6
457,0
20,9
500,0
21,5
536,0
22,2
578,0
25,4
681,0
26,1
710,0
29,8
940,0
34,2
1180,0
8,6
64,0
9,2
82,0
9,0
82,0
9,8
99,0
9,6
99,0
10,8
123,0
10,5
123,0
11,7
148,0
12,1
148,0
12,6
172,0
13,8
198,0
14,9
274,0

Weight
approx.
kg/km
688,0
730,0
950,0
971,0
1100,0
1290,0
1510,0
1640,0
97,0
103,0
103,0
146,0
146,0
169,0
169,0
199,0
219,0
219,0
270,0
330,0
350,0
400,0
422,0
514,0
545,0
640,0
689,0
710,0
762,0
910,0
1070,0
1092,0
1315,0
1370,0
1610,0
1840,0
130,0
152,0
152,0
168,0
168,0
202,0
202,0
304,0
304,0
336,0
420,0
434,0

AWG-No.
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16


Part no.
16279
16280
16281
16282
16317
16283
16284
16285
16286
16287
16288
16456
16289
16290
16291
16292
16293
16294
16295
16296
16297
16298
16318
16299
16300
16301
16302
16303
16304
16305
16306
16307
16308
16309
16310
16311
16312
16313
16460
16314
16461
16462
16463
16464
16465
16157
16466
16158
16467
16159
16468
16160
16167
16168

No.cores x
cross-sec.
mm
14G1,5
16G1,5
18G1,5
20G1,5
21G1,5
24G1,5
25G1,5
28G1,5
30G1,5
35G1,5
40G1,5
41G1,5
50G1,5
61G1,5
80G1,5
100G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
10G2,5
12G2,5
2x4
3G4
4G4
5G4
7G4
2x6
3G6
4G6
5G6
7G6
2x10
3G10
4G10
5G10
7G10
4G16
5G16
4G25
5G25
4G35
5G35
4G50
5G50
4G70
5G70
4G95
5G95
4G120
5G120
4G150
5G150

Outer
Cop.
approx. mm weight
kg/km
15,8
294,0
16,7
318,0
17,4
386,0
18,5
401,0
18,5
447,0
20,4
487,0
20,6
531,0
21,6
562,0
21,6
598,0
23,2
685,0
25,0
759,0
25,0
840,0
27,4
997,0
29,2
1120,0
33,4
1360,0
37,6
1690,0
10,1
110,0
10,8
148,0
11,5
169,0
12,8
220,0
14,1
284,0
16,4
369,0
17,9
470,0
11,8
124,0
12,5
178,0
13,7
234,0
15,0
284,0
16,4
321,0
13,7
176,0
14,4
245,0
15,7
316,0
17,3
442,0
19,0
530,0
16,6
260,0
17,6
367,0
19,4
549,0
21,3
604,0
23,6
820,0
23,4
807,0
26,0
940,0
28,3
1169,0
31,5
1420,0
32,4
1680,0
36,5
2020,0
38,6
2370,0
43,0
2880,0
46,1
3257,0
50,9
4032,0
51,1
4060,0
56,0
5244,0
56,5
5231,0
62,1
6624,0
64,6
7760,0
70,6
8496,0

Weight
approx.
kg/km
480,0
525,0
640,0
690,0
720,0
770,0
805,0
900,0
950,0
1100,0
1350,0
1381,0
1675,0
1800,0
2300,0
2600,0
180,0
216,0
267,0
347,0
407,0
660,0
722,0
302,0
340,0
410,0
502,0
638,0
350,0
450,0
559,0
702,0
907,0
500,0
750,0
1020,0
1115,0
1500,0
1380,0
1553,0
1890,0
2270,0
2390,0
2885,0
3315,0
4150,0
4600,0
5750,0
6060,0
7580,0
7315,0
9150,0
9680,0
10170,0

AWG-No.
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
12
12
12
12
12
10
10
10
10
10
8
8
8
8
8
6
6
4
4
2
2
1
1
2/0
2/0
3/0
3/0
4/0
4/0
300 kcmil
300 kcmil

Dimensions and specifications may be changed without prior notice. (RA01)

A 33
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SY-JZ

flexible, number coded, with steel wire braiding, meter marking

Technical data

Cable structure

Properties

Special PVC control cable in accordanceto


DIN VDE0281, 0293, 0295
Temperature range
flexing -15 C1) to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 20x cable
fixed installation 6x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
1) cold bending test, impact resistance test
at low temperatures, elongation test at low
temperatures. Tested according VDE0473
part811-1-4, EN60811-1-4

Bare copper, fine wire conductors,to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of special PVC Z7225
Black cores with white figure imprint to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC inner jacket
Galvanized steel wire braid
Special PVC outer jacket
Colour transparent (also available in grey)
with meter marking, change-over in 2011

Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB) for
outer jacket grey
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
Further dimensions available on request.
These cables con be also delivered with
coloured conductors (SY-JB).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
when ordering.
screened analogue type:
SY-JB,, see pageA40

Application
SY-JZ cables are used as measuring and control cables in tool machinery, plant installation, power stations and in data equipment. The braided
screen offers best possible protection against mechanical damage. The galvanized coating on the steel wire braiding not only helps protect
against corrosion, but also notably improves the soldering performance.
The clear transparent outer sheath gives the cable in addition an optical revaluation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
12001
12002
12003
12004
12005
12006
12007
12008
12009
12010
12114
12012
12013
12014
12015
12016
12017
12018
12011
12019
12020
12021
12022
12112
12023
12188
12024
12113
12025
12026

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
10G0,5
12G0,5
14G0,5
18G0,5
21G0,5
25G0,5
30G0,5
35G0,5
40G0,5
42G0,5
50G0,5
61G0,5
80G0,5
100G0,5
2x0,75
3G0,75
4G0,75
5G0,75
6G0,75
7G0,75
8G0,75
9G0,75
10G0,75
12G0,75
15G0,75

Outer
Cop.
approx. mm weight
kg/km
7,3
9,6
7,6
14,4
8,2
19,2
8,9
24,0
9,5
33,6
11,1
48,0
11,8
58,0
12,5
67,0
13,6
86,0
14,3
101,0
15,7
120,0
16,4
144,0
17,9
168,0
18,4
192,0
19,1
202,0
20,9
240,0
22,4
293,0
25,4
384,0
28,6
480,0
7,9
14,4
8,2
21,6
8,7
28,8
9,5
36,0
10,1
43,2
10,3
50,0
10,8
57,6
11,8
65,0
11,8
72,0
12,8
86,0
14,2
108,0

Weight
approx.
kg/km
80,0
92,0
102,0
119,0
157,0
205,0
218,0
242,0
340,0
370,0
406,0
439,0
500,0
565,0
593,0
690,0
843,0
1050,0
1240,0
98,0
103,0
122,0
142,0
180,0
185,0
201,0
249,0
252,0
292,0
335,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18


Part no.
12027
12028
12029
12030
12031
12032
12033
12034
12035
12036
12037
12038
12039
12040
12041
12042
12043
12044
12045
12046
12047
12048
12049
12050
12051
12052
12053
12054
12055
12056

No.cores x
cross-sec.
mm
18G0,75
21G0,75
25G0,75
32G0,75
34G0,75
41G0,75
50G0,75
61G0,75
2x1
3G1
4G1
5G1
6G1
7G1
8G1
9G1
12G1
14G1
18G1
20G1
25G1
34G1
36G1
41G1
50G1
56G1
61G1
65G1
80G1
100G1

Outer
Cop.
approx. mm weight
kg/km
15,0
130,0
15,5
151,0
17,3
180,0
19,1
230,0
19,9
245,0
21,2
296,0
23,2
360,0
25,2
439,0
8,2
19,2
8,5
28,8
9,2
38,4
9,9
48,0
10,5
58,0
10,7
67,0
11,3
77,0
12,6
86,0
13,4
115,0
14,2
134,0
15,7
173,0
16,3
192,0
18,4
240,0
20,9
326,0
20,9
346,0
22,2
394,0
24,4
480,0
25,5
538,0
26,3
586,0
26,9
624,0
30,0
768,0
34,6
960,0

Weight
approx.
kg/km
388,0
474,0
503,0
644,0
663,0
741,0
925,0
1082,0
112,0
132,0
143,0
166,0
22,0
227,0
277,0
295,0
340,0
420,0
500,0
532,0
664,0
845,0
857,0
993,0
1112,0
1225,0
1306,0
1504,0
1750,0
1950,0

AWG-No.
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17

Continuation

A 34
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SY-JZ

flexible, number coded, with steel wire braiding, meter marking

Part no.
12057
12058
12059
12060
12109
12061
12062
12063
12064
12065
12066
12067
12068
12069
12070
12071
12072
12073
12074
12075
12076
12077
12078
12079
12080
12081
12082
12083
12084
12085
12086
12087
12088
12089
12090

No.cores x
cross-sec.
mm
2x1,5
3G1,5
4G1,5
5G1,5
6G1,5
7G1,5
8G1,5
9G1,5
10G1,5
11G1,5
12G1,5
14G1,5
18G1,5
25G1,5
32G1,5
34G1,5
42G1,5
50G1,5
61G1,5
80G1,5
100G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
14G2,5
18G2,5
20G2,5
25G2,5
30G2,5
34G2,5
50G2,5
61G2,5

Outer
Cop.
approx. mm weight
kg/km
8,8
29,0
9,4
43,0
10,0
58,0
10,9
72,0
11,8
87,0
11,8
101,0
12,7
115,0
13,9
130,0
13,9
144,0
15,0
158,0
15,0
173,0
15,8
202,0
17,4
259,0
20,6
360,0
22,3
461,0
23,2
490,0
25,2
605,0
27,6
720,0
29,4
878,0
33,8
1152,0
38,0
1440,0
10,2
48,0
10,9
72,0
11,6
96,0
12,9
120,0
14,2
168,0
17,7
288,0
18,8
336,0
21,0
432,0
22,1
480,0
24,4
600,0
26,0
720,0
28,4
816,0
34,0
1200,0
36,3
1464,0

Weight
approx.
kg/km
129,0
149,0
185,0
205,0
255,0
285,0
340,0
347,0
418,0
430,0
444,0
533,0
593,0
781,0
1015,0
1124,0
1401,0
1583,0
1810,0
2316,0
2900,0
185,0
248,0
290,0
347,0
420,0
660,0
750,0
893,0
1169,0
1458,0
1686,0
1869,0
2200,0
3000,0

AWG-No.
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14
14
14
14
14
14
14


Part no.
12115
12091
12092
12093
12094
12095
12096
12097
12098
12099
12100
12101
12102
12103
12104
12105
12106
12107
12108
12116
12111
12117
12110
12118
12119
12327

No.cores x
cross-sec.
mm
3G4
4G4
5G4
7G4
11G4
4G6
5G6
7G6
4G10
5G10
7G10
4G16
5G16
7G16
4G25
5G25
4G35
5G35
4G50
5G50
4G70
5G70
4G95
5G95
4G120
4G150

Outer
Cop.
approx. mm weight
kg/km
12,6
117,0
13,8
154,0
15,1
192,0
16,4
269,0
21,2
422,0
15,8
230,0
17,3
288,0
19,0
403,0
19,4
384,0
21,3
480,0
23,6
672,0
23,8
614,0
26,6
768,0
29,2
1075,0
29,3
960,0
32,5
1200,0
33,4
1344,0
37,1
1680,0
39,8
1920,0
44,1
2400,0
46,3
2688,0
50,9
3360,0
51,4
3648,0
56,5
4560,0
56,6
4608,0
64,3
5760,0

Weight
approx.
kg/km
350,0
428,0
504,0
640,0
1204,0
571,0
671,0
845,0
943,0
1065,0
1551,0
1360,0
1740,0
2166,0
2020,0
2465,0
2570,0
3185,0
3513,0
4248,0
4810,0
5880,0
6360,0
8071,0
8170,0
9970,0

AWG-No.
12
12
12
12
12
10
10
10
8
8
8
6
6
6
4
4
2
2
1
1
2/0
2/0
3/0
3/0
4/0
300 kcmil

Dimensions and specifications may be changed without prior notice. (RA01)

A 35
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-600-Y-CY

flexible, number coded, 0,6/1kV, Cu screened meter marking,

EMC-preferred type

Technical data

Cable structure

Properties

In accordance to DIN VDE 0262/12.95 and


DIN VDE 0281 part 13
Temperature range
flexing -15 C1) to +80 C
fixed installation -40 C to +90 C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Power rating
according to DIN VDE 0298
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Coupling resistance
max. 250 Ohm/km
1) cold bending test, impact resistance test
at low temperatures, elongation test at low
temperatures. Tested according VDE0473
part811-1-4, EN60811-1-4

Bare copper, fine wire conductors,


according to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Special PVC core insulation TI2, to
DINVDE0281 part1
Black cores with sequential numbering
imprinted in white, according to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
PVC-insulated inner sheath
Braided screen of tinned Cu wires,
coverage approx. 85%
Special PVC outer sheath TM2, to
DINVDE0281 part1
colour black (RAL 9005)
with meter marking, change-over in 2011

Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
UV resistant


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
Further sizes are available upon request.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
JZ-600, see pageA16

Application
Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air
conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with
free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable
to be used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable,
even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located
in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and
Arabian countries. Interference-free transmission of signals and pulses is assured by the high degree of screening.
EMC = Electromagnetic compatibility
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
11464
11465
11466
11467
11469
11472
11475
11478
11489
11490
11491
11492
11494
11498
11501
11504

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75

Outer
Cop.
approx. mm weight
kg/km
8,5
41,0
8,8
45,0
9,6
54,0
10,2
66,0
11,1
79,0
14,0
137,0
16,2
156,0
19,1
250,0
8,8
46,0
9,3
57,0
9,9
63,0
10,8
76,0
11,5
100,0
14,8
175,0
17,1
240,0
20,2
306,0

Weight
approx.
kg/km
129,0
150,0
170,0
199,0
235,0
320,0
428,0
503,0
143,0
155,0
190,0
228,0
323,0
410,0
560,0
730,0

AWG-No.
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18


Part no.
11516
11517
11518
11519
11521
11525
11528
11532
11546
11547
11548
11549
11551
11556
11559
11563

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
12G1
18G1
25G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5

Outer
Cop.
approx. mm weight
kg/km
9,4
54,0
9,8
64,0
10,6
76,0
11,4
89,0
12,5
114,0
15,7
186,0
18,4
284,0
21,6
387,0
10,6
64,0
11,1
82,0
11,8
99,0
13,1
123,0
14,2
148,0
18,1
274,0
21,4
386,0
24,9
531,0

Weight
approx.
kg/km
150,0
163,0
200,0
239,0
289,0
464,0
628,0
855,0
162,0
187,0
240,0
289,0
383,0
592,0
806,0
1241,0

AWG-No.
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16

Continuation

A 36
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-600-Y-CY

flexible, number coded, 0,6/1kV, Cu screened meter marking,

EMC-preferred type

Part no.
11574
11575
11576
11577
11578
11580
11582
11584
11590
11591
11592
11593
11594
11596
11597
11598
11599
11600
11601
11602
11603
11604
11605
11606
11607

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5
2x4
3G4
4G4
5G4
7G4
12G4
2x6
3G6
4G6
5G6
7G6
2x10
3G10
4G10
5G10
7G10
2x16

Outer
Cop.
approx. mm weight
kg/km
12,1
110,0
12,7
148,0
13,8
169,0
15,1
220,0
16,6
284,0
21,3
470,0
25,4
572,0
29,6
740,0
13,8
124,0
14,4
178,0
15,7
234,0
17,3
284,0
19,0
321,0
24,4
581,0
15,2
176,0
15,9
245,0
17,3
316,0
19,2
442,0
21,0
530,0
18,6
260,0
19,7
367,0
21,5
549,0
23,7
604,0
26,0
820,0
22,4
491,0

Weight
approx.
kg/km
272,0
298,0
345,0
427,0
561,0
857,0
1355,0
1995,0
306,0
391,0
527,0
700,0
920,0
1510,0
420,0
629,0
731,0
1105,0
1465,0
845,0
1125,0
1345,0
1635,0
2210,0
1150,0

AWG-No.
14
14
14
14
14
14
14
14
12
12
12
12
12
12
10
10
10
10
10
8
8
8
8
8
6


Part no.
11608
11609
11610
11611
11612
11613
11614
11615
11616
11617
11618
11619
11620
11621
11622
11623
11624
11625
11626
11627
11628
11629
13137
13147

No.cores x
cross-sec.
mm
3G16
4G16
5G16
7G16
3G25
4G25
5G25
7G25
3G35
4G35
5G35
3G50
4G50
5G50
3G70
4G70
5G70
3G95
4G95
5G95
3G120
4G120
4G150
4G185

Outer
Cop.
approx. mm weight
kg/km
23,7
653,0
26,1
807,0
29,0
940,0
31,8
1345,0
28,7
920,0
31,7
1169,0
35,0
1420,0
38,4
1921,0
31,2
1250,0
34,5
1680,0
38,1
2020,0
36,9
1887,0
40,7
2370,0
45,2
2880,0
41,8
2516,0
46,0
3257,0
50,4
4032,0
46,8
3086,0
51,3
4060,0
56,4
5244,0
51,9
4176,0
56,4
5231,0
64,3
7760,0
67,5
8104,0

Weight
approx.
kg/km
1395,0
1870,0
2720,0
3213,0
2465,0
2750,0
3490,0
4980,0
3230,0
4100,0
4950,0
4590,0
5780,0
7210,0
5610,0
7480,0
9390,0
8585,0
10220,0
13800,0
11105,0
13750,0
15990,0
18470,0

AWG-No.
6
6
6
6
4
4
4
4
2
2
2
1
1
1
2/0
2/0
2/0
3/0
3/0
3/0
4/0
4/0
300 kcmil
350 kcmil

Dimensions and specifications may be changed without prior notice. (RA01)

A 37
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Y-CY-JB

flexible, CU-screened, transparent, EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Special PVC control cable in accordance to


E DIN VDE 0281 part 13
Temperature range
flexing -15 C1) to +80 C
fixed installation -40 C to +80 C
Nominal voltage
U0/U 300/500 V to 1,5 mm
U0/U 450/750 V at 2,5 mm
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Mutual capacitance according to
different cross-sections
0,5 mm to 2,5 mm:
core/core approx. 150 nF/km
core/screen approx. 270 nF/km
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
1) cold bending test, impact resistance test
at low temperatures, elongation test at low
temperatures. Tested according VDE0473
part811-1-4, EN60811-1-4

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Core insulation of special PVC Z7225
Core colour coded to JB/OB colour code
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC inner sheath
Tinned copper, braided screen, approx.
85% coverage
Transparent special PVC outer sheath
with meter marking, change-over in 2011


Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OB).
by 5 cores with VDE-Reg. No.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
JB-500, see pageA21
JB-750, see pageA22

Application
For use as a data and control cable in machinery, computer systems etc. as well as a signal cable for electronics. The high level of screening
ensures a high degree of interference protection. The screening density assures disturbance-free transmission of all signals and impulses.
The PVC-inner sheaths of those cables raise the mechanical stress. The applied clear transparent PVC outer sheath accentuates the optical
view of the tinned copper braid. These cables are suitable for flexible use for medium mechanical stresses with free movements.
The dense screening assures disturbance-free transmission of all signals and impulses. An ideal disturbance-free control cable for the above
application.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
16121
16122
16123
16124
16125
16126
16127
16128
16129
16130
16131
16132
16133
16134
16135
16136

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
2x0,75
3G0,75
4G0,75
5G0,75
2x1
3G1
4G1
5G1
2x1,5
3G1,5
4G1,5
5G1,5

Outer
Cop.
approx. mm weight
kg/km
7,1
41,0
7,4
45,0
8,0
54,0
8,5
66,0
7,7
46,0
8,0
57,0
8,5
63,0
9,3
76,0
8,0
54,0
8,3
64,0
9,0
76,0
9,7
89,0
8,6
64,0
9,2
82,0
9,8
99,0
10,8
123,0

Weight
approx.
kg/km
67,0
83,0
94,0
108,0
87,0
98,0
113,0
130,0
97,0
103,0
146,0
169,0
130,0
152,0
168,0
202,0

AWG-No.
20
20
20
20
18
18
18
18
17
17
17
17
16
16
16
16


Part no.
16137
16138
16139
16140
16141
16142
16143
16144
16145
16146
16147
16148
16149
16150
16151
16152

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
2x4
3G4
4G4
5G4
2x6
3G6
4G6
5G6
2x10
3G10
4G10
5G10

Outer
Cop.
approx. mm weight
kg/km
11,3
110,0
11,8
148,0
12,7
169,0
14,1
220,0
13,4
124,0
14,2
178,0
15,3
234,0
16,8
284,0
14,7
176,0
15,4
245,0
16,8
316,0
18,6
442,0
18,0
260,0
19,1
367,0
21,1
549,0
23,3
604,0

Weight
approx.
kg/km
180,0
216,0
267,0
347,0
302,0
340,0
410,0
502,0
350,0
450,0
559,0
702,0
500,0
750,0
1020,0
1115,0

AWG-No.
14
14
14
14
12
12
12
12
10
10
10
10
8
8
8
8

Continuation

A 38
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Y-CY-JB

flexible, CU-screened, transparent, EMC-preferred type, meter marking

Part no.
16153
16154
16469
16155
16470
16156

No.cores x
cross-sec.
mm
4G16
5G16
4G25
5G25
4G35
5G35

Outer
Cop.
approx. mm weight
kg/km
25,3
807,0
28,2
940,0
31,2
1169,0
34,5
1420,0
33,8
1680,0
37,5
2020,0

Weight
approx.
kg/km
1380,0
1553,0
1890,0
2270,0
2390,0
2885,0

AWG-No.


Part no.

6
6
4
4
2
2

16471
16119
16472
16473
16474
16247
16319

No.cores x
cross-sec.
mm
4G50
5G50
4G70
4G95
4G120
4G150
4G185

Outer
Cop.
approx. mm weight
kg/km
40,2
2370,0
44,8
2880,0
45,9
3257,0
51,3
4060,0
56,5
5231,0
64,6
7760,0
67,4
8104,0

Weight
approx.
kg/km
3315,0
4150,0
4600,0
6060,0
7315,0
9340,0
11120,0

AWG-No.
1
1
2/0
3/0
4/0
300 kcmil
350 kcmil

Dimensions and specifications may be changed without prior notice. (RA01)

Conduits
Corrugated tubes
for standard applications
for lager sizes
scissile corrugated tubes
conduit glands
High exible conduits
plastic conduits with spiral spring
metal conduits
conduits glands
Conduit for heavy mechanical duty
metal conduits with plastic sheat
plastic conduits
conduits glands for metal conduits

You can nd conduits in our catalogue Cable Accessories.

A 39
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SY-JB

flexible, colour coded, with steel wire braiding, meter marking

Technical data

Cable structure

Properties

Special PVC control cables


Adapted to DINVDE 0281, 0293, 0295
Temperature range
flexing -15 C1) to +80 C
fixed installation -40 C to +80 C
Nominal voltage
U0/U 300/500 V up to 2,5 mm
U0/U 450/750 V as of 4,0 mm
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 20x cable
fixed installation 6x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
1) cold bending test, impact resistance test
at low temperatures, elongation test at low
temperatures. Tested according VDE0473
part811-1-4, EN60811-1-4

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of special PVC Z7225
Cores colour coded as per JB/OB colour
code, see Technical Informations
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC inner jacket
Galvanized steel wire screening
Special PVC outer jacket
Colour transparent (also available in grey)
with meter marking, change-over in 2011

Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OB).
Further dimensions available on request.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Please note the cleanroom qualification
when ordering.
screened analogue type:
SY-JZ, see pageA34

Application
SY-JB cables are used as measuring and control cables in tool machinery, plant installation, power stations and in data equipment. The
braided screen offers best possible protection against mechanical damage. The galvanized coating on the steel wire braiding not only helps
protect against corrosion, but also notably improves the soldering performance.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
12200
12201
12202
12203
12204
12205
12206
12218
12219
12220
12221
12312
12222
12223
12313
12224
12234
12235
12236
12237
12238
12239
12240
12241
12242
12256
12257
12258
12259
12260
12261
12262
12263
12264
12265
12266

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
10G0,5
12G0,5
2x0,75
3G0,75
4G0,75
5G0,75
6G0,75
7G0,75
9G0,75
10G0,75
12G0,75
2x1
3G1
4G1
5G1
6G1
7G1
8G1
9G1
12G1
2x1,5
3G1,5
4G1,5
5G1,5
6G1,5
7G1,5
8G1,5
9G1,5
10G1,5
11G1,5
12G1,5

Outer
Cop.
approx. mm weight
kg/km
7,3
9,6
7,6
14,4
8,2
19,2
8,9
24,0
9,5
33,6
11,1
48,0
11,8
58,0
7,9
14,4
8,2
21,6
8,7
28,8
9,5
36,0
10,1
43,2
10,3
50,0
11,8
65,0
11,8
72,0
12,8
86,0
8,2
19,2
8,5
28,8
9,2
38,4
9,9
48,0
10,5
58,0
10,7
67,0
11,3
77,0
12,6
86,0
13,4
115,0
8,8
29,0
9,4
43,0
10,0
58,0
10,9
72,0
11,8
87,0
11,8
101,0
12,7
115,0
13,9
130,0
13,9
144,0
15,0
158,0
15,0
173,0

Weight
approx.
kg/km
80,0
92,0
102,0
119,0
157,0
205,0
218,0
98,0
103,0
122,0
142,0
180,0
185,0
249,0
252,0
292,0
112,0
132,0
143,0
166,0
220,0
227,0
277,0
295,0
340,0
129,0
149,0
185,0
205,0
255,0
285,0
340,0
347,0
418,0
430,0
444,0

AWG-No.
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16


Part no.
12277
12278
12279
12280
12281
12282
12291
12318
12292
12293
12294
12295
12296
12297
12298
12319
12299
12300
12301
12320
12302
12303
12304
12321
12305
12306
12322
12307
12308
12323
12309
12314
12324
12310
12315

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
2x4
3G4
4G4
5G4
7G4
3G6
4G6
5G6
7G6
3G10
4G10
5G10
7G10
3G16
4G16
5G16
7G16
3G25
4G25
5G25
3G35
4G35
5G35
3G50
4G50
5G50
3G70
4G70
5G70

Outer
Cop.
approx. mm weight
kg/km
10,2
48,0
10,9
72,0
11,6
96,0
12,9
120,0
14,2
168,0
17,7
288,0
13,5
77,0
14,3
115,0
15,4
154,0
16,9
192,0
16,4
269,0
15,5
173,0
16,9
230,0
18,6
288,0
20,6
403,0
19,1
288,0
21,1
384,0
23,3
480,0
25,4
672,0
23,1
461,0
25,5
614,0
28,2
768,0
31,0
1075,0
28,4
720,0
31,2
960,0
34,5
1200,0
30,9
1008,0
34,0
1344,0
37,7
1680,0
37,0
1440,0
40,6
1920,0
45,2
2400,0
42,3
2016,0
46,3
2688,0
50,7
3360,0

Weight
approx.
kg/km
185,0
248,0
290,0
347,0
420,0
660,0
330,0
375,0
428,0
504,0
640,0
543,0
571,0
671,0
845,0
735,0
943,0
1065,0
1551,0
1080,0
1360,0
1740,0
2166,0
1630,0
2020,0
2465,0
1932,0
2570,0
3185,0
2679,0
3513,0
4248,0
2790,0
4810,0
5880,0

AWG-No.
14
14
14
14
14
14
12
12
12
12
12
10
10
10
10
8
8
8
8
6
6
6
6
4
4
4
2
2
2
1
1
1
2/0
2/0
2/0

Continuation

A 40
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SY-JB

flexible, colour coded, with steel wire braiding, meter marking

Part no.
12325
12311
12316

No.cores x
cross-sec.
mm
3G95
4G95
5G95

Outer
Cop.
approx. mm weight
kg/km
47,1
2736,0
51,3
3648,0
56,3
4560,0

Weight
approx.
kg/km
4870,0
6360,0
8071,0

AWG-No.
3/0
3/0
3/0


Part no.
12326
12317
12328

No.cores x
cross-sec.
mm
3G120
4G120
4G150

Outer
Cop.
approx. mm weight
kg/km
51,8
3456,0
56,4
4608,0
64,2
5760,0

Weight
approx.
kg/km
6230,0
8170,0
9970,0

AWG-No.
4/0
4/0
300 kcmil

Dimensions and specifications may be changed without prior notice. (RA01)

Tools
Cable shears
Box spanners
Strippers
Crimping tools
Pliers
Skinning knife

You can nd tools in our catalogue Cable Accessories.

A 41
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-500 PUR
PUR-JZ
PUR-ORANGE
PUR-YELLOW
H05 BQ-F / H07 BQ-F (NGMH11Y)
UNIPUR
PUR-750
JZ 500-FC-PUR
F-C-PUR-JZ
Y-C-PUR-JZ
UNIPUR-CP
PUR-C-PUR
Photo: Hller Hille GmbH

PUR Control Cables


The machinery and plant industries but especially
the tool making industries are working particularly with mineral oils, alkalis and aggressive collant
emulsions and under difcult working environmental conditions.
Due to these conditions the electrical control
cables, data cables as well as cables for trailing
chains have to perform to exceptionally high
standards. Flexibility, abrasion and oil resistance
have to be guaranteed.

HELUKABEL in co-operation with the leading


machine and plant industries have developed
suitable and application orientated cables.
These cables are tested, among other things,
with PUR cables are tested among the others,
mineral and synthetic oils, cutting oils, coolant
emulsions, etc. For the operation in power
trailing chains, these cables are tested to
multimillion alternating bending cycles.
Consequently we believe that we can deliver the
right cable for your application needs.

A 42
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-500 PUR

tear and coolant resistant, meter marking

Technical data

Cable structure

Properties

Special PUR cables adapted to


DINVDE0281
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Special PVC core insulation TI2, according
to DINVDE0281 part1
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special full-polyurethane outer jacket
TMPU, to DIN EN 50363-10-2 
Sheath colour grey (RAL 7001)
Jacket also available in other colours
with meter marking, change-over in 2011

Resistant to
UV-Radiation, Oxygene, Ozone and
hydrolysis Microbes
Low adhesion, matt surface
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
JZ-500-FC-PUR, see pageA52

Application
JZ-500 PUR is an extremely robust control cable with high abrasion and tear resistant properties. Due to its high resistance coolant emulsions,
it is especially suited for use in the machine, tool making and plant industries as well as in the steel industry for difficult and problem areas.
The high flexibility of this cable type makes it quick and easy to install. Suitable for outdoor lying.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
23314
23315
23316
23317
23318
23319
23320
23321
23322
23323
23324
23325
23326
23327
23328
23329
23330
23331
23332
23333
23334
23335
23336
23337
23338
23339
23340
23341
23342
23343
23344
23345
23346
23347
23348
23349
23350
23351

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4G0,5
4x0,5
5G0,5
5x0,5
7G0,5
7x0,5
10G0,5
12G0,5
18G0,5
25G0,5
34G0,5
42G0,5
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
7G0,75
7x0,75
10G0,75
12G0,75
18G0,75
25G0,75
34G0,75
42G0,75
2x1
3G1
3x1
4G1
4x1
5G1
5x1
7G1

Outer
Cop.
approx. mm weight
kg/km
4,9
9,6
5,2
14,4
5,2
14,4
5,6
19,0
5,6
19,0
6,3
24,0
6,3
24,0
6,9
33,6
6,9
33,6
8,3
48,0
8,8
58,0
11,0
86,0
12,9
120,0
14,9
163,0
16,1
202,0
5,3
14,4
5,6
21,6
5,6
21,6
6,3
29,0
6,3
29,0
6,9
36,0
6,9
36,0
7,5
50,0
7,5
50,0
9,2
72,0
9,8
86,0
12,2
130,0
14,3
180,0
16,7
245,0
18,0
302,0
5,6
19,0
5,9
29,0
5,9
29,0
6,6
38,0
6,6
38,0
7,3
48,0
7,3
48,0
8,1
67,0

Weight
approx.
kg/km
45,0
55,0
55,0
65,0
65,0
75,0
75,0
90,0
90,0
120,0
135,0
205,0
270,0
380,0
415,0
44,0
53,0
53,0
64,0
64,0
76,0
76,0
96,0
96,0
140,0
170,0
260,0
282,0
475,0
600,0
53,0
63,0
63,0
75,0
75,0
89,0
89,0
115,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17


Part no.
23352
23353
23354
23355
23356
23357
23358
23359
23360
23361
23362
23363
23364
23365
23366
23367
23368
23369
23370
23371
23372
23373
23374
23375
23376
23377
23378
23379
23380
23381
23382
23383
23384
23385
23386
23387
23388

No.cores x
cross-sec.
mm
7x1
10G1
12G1
18G1
25G1
34G1
42G1
50G1
2x1,5
3G1,5
3x1,5
4G1,5
4x1,5
5G1,5
5x1,5
7G1,5
7x1,5
12G1,5
18G1,5
25G1,5
30G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
4G4
5G4
7G4
4G6
5G6
7G6
4G10
5G10
7G10
4G16

Outer
Cop.
approx. mm weight
kg/km
8,1
67,0
9,8
96,0
10,4
115,0
12,9
173,0
15,4
240,0
17,9
326,0
19,4
403,0
21,2
480,0
6,4
29,0
6,8
43,0
6,8
43,0
7,4
58,0
7,4
58,0
8,3
72,0
8,3
72,0
9,2
101,0
9,2
101,0
12,0
173,0
14,6
259,0
17,4
360,0
18,6
410,0
7,8
48,0
8,3
72,0
9,2
96,0
10,1
120,0
11,2
168,0
14,8
288,0
11,0
154,0
12,3
192,0
13,6
269,0
13,0
230,0
14,5
288,0
16,2
403,0
16,4
384,0
18,3
480,0
20,2
672,0
20,0
614,0

Weight
approx.
kg/km
115,0
166,0
201,0
289,0
380,0
645,0
730,0
890,0
68,0
87,0
87,0
106,0
106,0
131,0
131,0
173,0
173,0
293,0
454,0
641,0
800,0
110,0
146,0
183,0
222,0
293,0
512,0
291,0
355,0
503,0
468,0
570,0
808,0
720,0
894,0
1295,0
1063,0

AWG-No.
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
12
12
12
10
10
10
8
8
8
6

Dimensions and specifications may be changed without prior notice. (RA02)

A 43
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR-JZ

tear and coolant resistant, increased oil resistant, meter marking

Technical data

Cable structure

Special PUR cable in accordance to


DINVDE0281
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Oil resistant PVC core insulation TI2, in
adapted to DINVDE0281 part1, for better
sliding abilities
Black cores with continuous white figure
imprint to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special full-polyurethane outer jacket
TMPU, to DIN EN 50363-10-2 
Sheath colour grey (RAL 7001)
Jacket also available in other colours
with meter marking, change-over in 2011

Properties

Resistant to
UV-Radiation, Oxygene, Ozone
Hydrolysis, Microbes
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
F-C-PUR-JZ, see pageA54
Y-C-PUR-JZ, see pageA56

Application
PUR-JZ is an extremely robust control cable with high abrasion and tear resistant properties. With high-grade oil resistant PVC core insulation.
Due to its high resistance to mineral oils and especially to coolant emulsions, it is especially suited for use in the machine, tool making,
plantconstruction as well as in the steel industry for difficult and problem areas. For medium mechanical stress for flexible use with free
movement without tensile stress or forced movements in dry, damp and wet rooms and in open air. The high flexibility of this cable type
makes it quick and easy to install.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
22100
22101
22102
22103
22104
22105
22106
22107
22108
22109
22110
22111
22112
22113
22114
22115
22116
22117
22118
22119
22120
22121
22122
22123
22124
22125
22126
22127
22128
22129
22130
22131

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
8G0,5
10G0,5
12G0,5
14G0,5
18G0,5
21G0,5
25G0,5
30G0,5
34G0,5
42G0,5
50G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
8G0,75
10G0,75
12G0,75
14G0,75
18G0,75
21G0,75
25G0,75
30G0,75
34G0,75
42G0,75
50G0,75

Outer
Cop.
approx. mm weight
kg/km
4,9
9,6
5,2
14,4
5,6
19,0
6,3
24,0
6,9
33,6
7,4
38,0
8,3
48,0
8,8
58,0
9,7
67,0
11,0
86,0
11,5
96,0
12,9
120,0
13,8
144,0
14,9
163,0
16,1
202,0
17,9
240,0
5,3
14,4
5,6
21,6
6,3
29,0
6,9
36,0
7,5
50,0
8,2
58,0
9,2
72,0
9,8
86,0
10,6
101,0
12,2
130,0
12,7
151,0
14,3
180,0
15,3
216,0
16,7
245,0
18,0
302,0
19,8
360,0

Weight
approx.
kg/km
45,0
55,0
65,0
75,0
90,0
105,0
120,0
135,0
170,0
205,0
225,0
270,0
315,0
380,0
415,0
550,0
44,0
53,0
64,0
76,0
96,0
111,0
140,0
170,0
202,0
260,0
269,0
282,0
400,0
475,0
600,0
720,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18


Part no.
22132
22133
22134
22135
22136
22137
22138
22139
22140
22141
22142
22143
22144
22145
22146
22147
22148
22149
22150
22151
22152
22153
22154
22155
22156
22157
22158
22159
22160
22161
22162
22163

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
8G1
10G1
12G1
14G1
18G1
21G1
25G1
32G1
34G1
42G1
50G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5
14G1,5
18G1,5
21G1,5
25G1,5
30G1,5
34G1,5
42G1,5
50G1,5

Outer
Cop.
approx. mm weight
kg/km
5,6
19,0
5,9
29,0
6,6
38,0
7,3
48,0
8,1
67,0
8,7
77,0
9,8
96,0
10,4
115,0
11,4
134,0
12,9
173,0
13,7
196,0
15,4
240,0
17,1
308,0
17,9
326,0
19,4
403,0
21,2
480,0
6,4
29,0
6,8
43,0
7,4
58,0
8,3
72,0
9,2
101,0
9,9
115,0
10,9
144,0
12,0
173,0
13,0
202,0
14,6
259,0
15,5
302,0
17,4
360,0
18,6
410,0
20,2
490,0
21,8
605,0
24,2
720,0

Weight
approx.
kg/km
53,0
63,0
75,0
89,0
115,0
131,0
166,0
201,0
230,0
289,0
306,0
380,0
620,0
645,0
730,0
890,0
68,0
87,0
106,0
131,0
173,0
199,0
245,0
293,0
347,0
454,0
534,0
641,0
800,0
945,0
1100,0
1250,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

Continuation

A 44
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR-JZ

tear and coolant resistant, increased oil resistant, meter marking

Part no.
22164
22165
22166
22167
22168
22169
22170
22171
22172
22173
22174
22175
22176
22177
22178
22179
22180

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5
2x4
3G4
4G4
5G4
7G4
3G6
4G6
5G6
7G6

Outer
Cop.
approx. mm weight
kg/km
7,8
48,0
8,3
72,0
9,2
96,0
10,1
120,0
11,2
168,0
14,8
288,0
18,2
432,0
21,6
600,0
9,3
77,0
9,8
115,0
11,0
154,0
12,3
192,0
13,6
269,0
11,9
173,0
13,0
230,0
14,5
288,0
16,2
403,0

Weight
approx.
kg/km
110,0
146,0
183,0
222,0
293,0
512,0
740,0
940,0
147,0
228,0
291,0
355,0
503,0
362,0
468,0
570,0
808,0

AWG-No.
14
14
14
14
14
14
14
14
12
12
12
12
12
10
10
10
10


Part no.
22181
22182
22183
22184
22185
22186
22187
22188
22189
22190
22191
22192

No.cores x
cross-sec.
mm
3G10
4G10
5G10
7G10
4G16
5G16
7G16
4G25
4G35
4G50
4G70
4G95

Outer
Cop.
approx. mm weight
kg/km
14,8
288,0
16,4
384,0
18,3
480,0
20,2
672,0
20,0
614,0
22,6
768,0
24,8
1075,0
24,9
960,0
28,4
1344,0
34,2
1920,0
40,3
2688,0
45,8
3648,0

Weight
approx.
kg/km
555,0
720,0
894,0
1295,0
1063,0
1400,0
1800,0
1590,0
2200,0
2400,0
4400,0
6000,0

AWG-No.
8
8
8
8
6
6
6
4
2
1
2/0
3/0

Dimensions and specifications may be changed without prior notice. (RA02)

Signal and power circular connectors


Series A, B, C, D, F and S
Tools
Accessories
Online congurator
Pre-assembled cables

You can nd signal and power circular connectors in our catalogue Cable Accessories.

A 45
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR-ORANGE

high abrasion, coolant resistant, meter marking

Technical data

Cable structure

Properties

Special PVC/PUR control cable, adapted to


DINVDE0281,0282
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper conductor, fine wire stranded


to DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special PVC core insulation TI2, according
toDINVDE0281 part1
Cores numbered or colored according to
DINVDE0293-308
For 2-cores cable without green-yellow
earth core, core colours brown, blue black
cores with continuous white
numberingand green-yellow earth core
(up to 7 cores) or
cores colour coded with green-yellow earth
core (up to 5 cores)
Cores stranded in layers with optimal
lay-length
PVC-inner jacketguarantees agood
insulation cut-back
PUR-outer jacket TMPU, to DIN EN
50363-10-2  
Colour orange (RAL2003)
with meter marking, change-over in 2011

High flexibility at low temperature


High abrasion resistance
Resistant to
Oils and fats
Non-alcoholic fuels and kerosene
Atmospheric influences
UV-radiation, Oxygene and ozone
Microbes and rotting
Sea and waste water, vibrations
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core
(OZ/OB).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Robust control cable with an outstanding resistance to oil and abrasion. Suitable for use in tool making and machine industries, steel works,
on building sites and in the oil and coal industries. The cable can also be used for portable tools etc. To be recommended if the cable comes
into contact with chemical agents.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


PUR-jacket orange, cores numbered OZ/JZ


Part no.
22001
22002
22003
22004
22005
22006
22007
22008
22009
22010
22015
22016
22017
22018
22019
22025
22026
22027
22028
22029
22033
22034
22035
22036
22037
22038
22039
22040
22041
22042
22043

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
2x1
3G1
4G1
5G1
7G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
3G4
4G4
5G4
7G4
4G6
5G6
7G6
4G10
5G10
4G16
5G16

Outer
Cop.
approx. mm weight
kg/km
6,4
14,4
6,8
21,6
7,3
28,8
8,2
36,0
9,2
50,0
7,2
19,2
7,6
29,0
8,0
38,0
8,8
48,0
10,0
67,0
7,8
29,0
8,3
43,0
9,0
58,0
9,7
72,0
11,2
101,0
9,2
48,0
9,6
72,0
11,0
96,0
12,0
120,0
13,7
168,0
11,8
115,0
13,2
154,0
14,8
192,0
16,4
269,0
15,4
230,0
17,0
288,0
20,8
403,0
20,8
384,0
22,6
480,0
23,0
614,0
27,4
768,0

Weight
approx.
kg/km
50,0
70,0
80,0
100,0
140,0
63,0
76,0
95,0
120,0
170,0
80,0
105,0
135,0
158,0
221,0
150,0
173,0
203,0
253,0
356,0
250,0
300,0
370,0
500,0
480,0
583,0
780,0
740,0
920,0
1100,0
1400,0

AWG-No.
18
18
18
18
18
17
17
17
17
17
16
16
16
16
16
14
14
14
14
14
12
12
12
12
10
10
10
8
8
6
6

PUR-jacket orange OB/JB, cores colour coded to DIN VDE 0293


Part no.
22250
22251
22252
22253
22254
22255
22256
22257
22258
22259
22260
22261
22262
22263
22264
22265
22266
22267
22268
22269
22270
22271
22272
22273
22044
22045
22046

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
2x1
3G1
4G1
5G1
2x1,5
3G1,5
4G1,5
5G1,5
2x2,5
3G2,5
4G2,5
5G2,5
4G4
5G4
4G6
5G6
4G10
5G10
4G16
5G16
4G25
5G25
4G35

Outer
Cop.
approx. mm weight
kg/km
6,4
14,4
6,8
21,6
7,3
28,8
8,2
36,0
7,2
19,2
7,6
29,0
8,0
38,0
8,8
48,0
7,8
29,0
8,3
43,0
9,0
58,0
9,7
72,0
9,2
48,0
9,6
72,0
11,0
96,0
12,0
120,0
13,2
154,0
14,8
192,0
15,4
230,0
17,0
288,0
20,8
384,0
22,6
480,0
23,0
614,0
27,4
768,0
30,0
960,0
32,2
1200,0
33,0
1344,0

Weight
approx.
kg/km
50,0
70,0
80,0
100,0
63,0
76,0
95,0
120,0
80,0
105,0
135,0
158,0
150,0
173,0
203,0
253,0
300,0
370,0
480,0
583,0
740,0
920,0
1100,0
1400,0
1600,0
2000,0
2100,0

AWG-No.
18
18
18
18
17
17
17
17
16
16
16
16
14
14
14
14
12
12
10
10
8
8
6
6
4
4
2

Dimensions and specifications may be changed without prior notice. (RA02)

A 46
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR-YELLOW

PVC-inner jacket, high abrasion, coolant resistant, meter marking

Technical data

Cable structure

Properties

Special PVC/PUR cablein accordanceto


DINVDE0281,0282
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Special PVC core insulation TI2, to
DINVDE0281 part1
Core identification to DINVDE0293-308
up to 5 cores, colour coded
as of 7 cores, cores number 1 to 6
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
PVC inner sheath guarantees easy cable
stripping
PUR-outer jacket, TMPU to DIN EN
50363-10-2
Colour yellow (RAL 1021)
with meter marking, change-over in 2011

High flexibility at low temperature


High abrasion resistance
Resistant to
Oils and fats
Non-alcoholic fuels and kerosene
Atmospheric influences
UV-radiation
Oxygene and ozone
Microbes and rotting
Sea and waste water
Vibrations
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OB).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Further jacket colours e.g. black, green etc.
on request.
Art.no. 22212 = JB.
Art.no. 22220 = JZ.

Application
Robust control cable with an outstanding resistance to oil and abrasion. Suitable for use in tool making and machine industries, steel works,
on building sites and in the oil and coal industries. The cable can also be used for portable tools. etc. To be recommended if the cable comes
into contact with chemical agents.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
22200
22201
22202
22203
22204
22205
22206
22207
22208
22209
22210
22211

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
2x1
3G1
4G1
5G1
7G1
2x1,5
3G1,5

Outer
Cop.
approx. mm weight
kg/km
6,4
14,4
6,8
21,6
7,3
28,8
8,2
36,0
9,2
50,0
7,2
19,2
7,6
29,0
8,0
38,0
8,8
48,0
10,0
67,0
7,8
29,0
8,3
43,0

Weight
approx.
kg/km
50,0
70,0
80,0
100,0
140,0
63,0
76,0
95,0
120,0
170,0
80,0
105,0

AWG-No.
18
18
18
18
18
17
17
17
17
17
16
16


Part no.
22212
22220
22213
22214
22215
22216
22217
22218
22219
22221
22222
22233

No.cores x
cross-sec.
mm
4G1,5
4G1,5
5G1,5
7G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
4G4
5G4
4G35

Outer
Cop.
approx. mm weight
kg/km
9,0
58,0
13,7
58,0
9,0
72,0
9,7
101,0
11,2
48,0
9,2
72,0
9,6
96,0
11,0
120,0
12,0
168,0
14,6
153,6
14,8
192,0
33,0
1344,0

Weight
approx.
kg/km
135,0
135,0
158,0
221,0
150,0
173,0
203,0
253,0
356,0
310,0
370,0
2100,0

AWG-No.
16
16
16
16
14
14
14
14
14
12
12
2

Dimensions and specifications may be changed without prior notice. (RA02)

A 47
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H05 BQ-F / H07 BQ-F (NGMH11Y)




Technical data

Cable structure

Properties

EPR/PUR-insulated power cable according


to DINVDE0282 part10 and HD22.10S1
Temperature range
flexing -40 C to +80 C
fixed installation -50 C to +90 C
Permissible operating temperature
at conductor 90 C
Nominal voltage a.c., 50 Hz
H05BQ-F: U0/U 300/500 V up to 1 mm
H07BQ-F: U0/U 450/750 V as of 1,5 mm
Test voltage
H05BQ-F: 2000 V up to 1 mm
H07BQ-F: 2500 V as of 1,5 mm
Minimum bending radius
flexing 5x cable
fixed installation 3x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Plain copper conductor, stranded


according to DINVDE0295 cl.5, BS6360
cl.5 and HD383 cl.5
Insulating jacket of rubber, compound EI6
according to DINVDE0282 part1
Core identification according to
DINVDE0293-308 and HD308 S2
Green-yellow earth core in the outer layer
Cores stranded in layers with optimal
lay-length (inner fill compound permissible)
PUR-insulated outer jacket TMPU, to DIN
EN 50363-10-2 
Colour orange (RAL2003)
Minimum imprinted designation BQ

Abrasion resistant
Notch resistant
Resistant to tearing and cutting
Resistant to
Oils, fats, Petrol
Water and weathering effects
Oxygene and ozone
UV-radiation, Hydrolysis and Microbial
attack
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
7 G 1,5 mm and 12 G 1,5 mm are not
contained in VDE, adapted to VDE, (H)07BQ.

Application
These cables can be used for medium mechanical loads in dry, damp or wet environments, e.g. for connecting agricultural and commercial
equipment and heaters provided there is no danger of contact with the hot parts or by radiation of heat. These robust and flexible cables
are used for electrical tools such as drills and hand-held circular saws, as well as for portable motors and machinery in agriculture, at building
sites, docks and refrigeration plants.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


H05BQ-F
Part no.
22050
22051
22052
22053
22054
22055
22056
22057

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
2x1
3G1
4G1
5G1

Outer
Cop.
min. - max.
weight
approx. mm kg/km
5,7 - 7,4
14,4
6,2 - 8,1
21,6
6,8 - 8,8
29,0
7,6 - 9,9
36,0
6,1 - 8,0
19,2
6,5 - 8,5
29,0
7,1 - 9,3
38,4
8,0 - 10,3
48,0

Weight
approx.
kg/km
52,0
63,0
80,0
96,0
59,0
71,0
89,0
112,0

AWG-No.

No.cores x
cross-sec.
mm
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
2x2,5
3G2,5
4G2,5
5G2,5
2x4
3G4
4G4
5G4
2x6
3G6
4G6
5G6

Outer
Cop.
min. - max.
weight
approx. mm kg/km
7,6 - 9,8
29,0
8,0 - 10,4
43,0
9,0 - 11,6
58,0
9,8 - 12,7
72,0
12,5 - 16,3
101,0
16,5 - 21,5
173,0
9,0 - 11,6
48,0
9,6 - 12,4
72,0
10,7 - 13,8
96,0
11,9 - 15,3
120,0
10,6 - 13,7
77,0
11,3 - 14,5
115,0
12,7 - 16,2
154,0
14,1 - 17,9
192,0
11,8 - 15,1
115,0
12,8 - 16,3
173,0
14,2 - 18,1
230,0
15,7 - 20,0
288,0

Weight
approx.
kg/km
92,0
109,0
145,0
169,0
230,0
398,0
121,0
164,0
207,0
262,0
194,0
224,0
327,0
415,0
311,0
310,0
496,0
586,0

AWG-No.

Part no.
18
18
18
18
17
17
17
17

H07BQ-F
Part no.
22058
22059
22060
22061
22062
22063
22064
22065
22066
22067
22072
22068
22069
22080
22073
22070
22071
22081

H07BQ-F

16
16
16
16
16
16
14
14
14
14
12
12
12
12
10
10
10
10

22074
22076
22078
22082
22075
22077
22079
22083
22828
22829
22830
22831
22832
22833
22835
22836
22837
22838
22839
22840
22841
22842
22843

No.cores x
cross-sec.
mm
2x10
3G10
4G10
5G10
2x16
3G16
4G16
5G16
4G25
5G25
4G35
5G35
4G50
5G50
4G70
5G70
4G95
5G95
4G120
5G120
4G150
5G185
4G240

Outer
Cop.
min. - max.
weight
approx. mm kg/km
15,6 - 19,9
192,0
16,8 - 21,4
288,0
18,6 - 23,6
384,0
20,4 - 25,9
480,0
17,9 - 22,8
307,0
19,5 - 24,7
461,0
21,3 - 27,0
614,0
23,7 - 30,0
768,0
26,8 - 31,9
960,0
29,0 - 35,0
1220,0
29,0 - 35,0
1344,0
33,3 - 39,7
1680,0
34,8 - 41,2
1920,0
39,7 - 46,7
2400,0
39,5 - 46,5
2688,0
46,3 - 53,3
3368,0
45,5 - 52,5
3648,0
52,0 - 60,0
4560,0
51,5 - 60,5
4608,0
56,7 - 65,7
5760,0
56,3 - 65,3
5760,0
59,5 - 68,5
7104,0
68,3 - 77,3
9216,0

Weight
approx.
kg/km
428,0
640,0
738,0
968,0
600,0
758,0
1187,0
1475,0
1550,0
1920,0
2120,0
2600,0
2920,0
3700,0
3900,0
5020,0
5150,0
6520,0
6550,0
8050,0
7950,0
9350,0
12200,0

AWG-No.
8
8
8
8
6
6
6
6
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

Dimensions and specifications may be changed without prior notice. (RA02)

A 48
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

UNIPUR flexible at low temperature, with customer markings, halogen-free,


wear resistant, robust, meter marking


Technical data

Cable structure

Properties

Spezial TPE/PUR connecting cable adapted


to DIN VDE 0282 part 10
Temperature range
flexing -40 C to +90 C
Nominal voltage
up to 1 mm U0/U 300/500 V
above 1,5 mm U0/U 450/750 V
Test voltage 3000 V
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductions bunch


stranded according to DINVDE0295 cl.5,
BS6360 cl.5 and IEC60228 cl.5
Core insulation of termoplastic elastomere
(TPE)
Core colours according DINVDE0293-308
Core colour
- up to 5 cores one-coloured
- up 6 and more cores, black with white
numbering
- 3 and above, with green-yellow earth core
- 2 cores without green-yellow earth core

Cores
stranded in layers with optimal
lay-length
PUR outer sheath TMPU in adapted to DIN
EN 50363-10-2 
Jacket colour by request
with meter marking, change-over in 2011

Flame retardant according to


VDE0482-332-1-2, DIN EN60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Abrasion resistant, Notch resistant
Resistant to tearing and cutting
Good flexibility at low temperatures down
to -40 C
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OB).
Colour code:
0 = RAL 5015, blue
1 = RAL 6018, green
2 = RAL 8003, brown
3 = RAL 1021, yellow
4 = RAL 3000, red
5 = RAL 2003, orange
6 = RAL 4005, violet
7 = RAL 7001/7032, grey
Please add the individual part no. for order
with the identification colour code.
Further colours on request.
screened analogue type:
UNIPUR-CP, see pageA58

Application
These robust and flexible cables are used for electrical tools such as drills, hand-held circular saws, and garden equipment as well as for
portable motors and machinery in agriculture, at building sites, for hobbies, docks and refrigeration plants.
Extremely good mechanical characteristies e.g. compressive load, good abrasion and near-resistant.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
1812_
1813_
1814_
1815_
1816_
1817_
1818_
1819_
1820_
1821_

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5
34G0,5
41G0,5

Outer
Cop.
approx. mm weight
kg/km
6,0
9,6
6,2
14,4
7,0
19,0
7,5
24,0
9,2
33,6
11,5
58,0
13,2
86,0
15,9
120,0
18,8
163,0
20,2
197,0

Weight
approx.
kg/km
40,0
47,0
57,0
65,0
94,0
150,0
208,0
276,0
393,0
460,0

AWG-No.
20
20
20
20
20
20
20
20
20
20


Part no.
1822_
1823_
1824_
1825_
1826_
1827_
1828_
1829_
1830_
1831_
1832_

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
6G0,75
7G0,75
12G0,75
18G0,75
25G0,75
34G0,75
41G0,75

Outer
Cop.
approx. mm weight
kg/km
6,3
14,0
6,9
21,6
7,5
28,8
8,3
36,0
9,0
43,0
9,8
50,0
12,2
86,0
14,1
130,0
17,5
180,0
20,3
245,0
21,9
296,0

Weight
approx.
kg/km
52,0
62,0
80,0
94,0
111,0
160,0
191,0
267,0
376,0
506,0
596,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18

Continuation

A 49
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

UNIPUR flexible at low temperature, with customer markings, halogen-free,


wear resistant, robust, meter marking

Part no.
1833_
1834_
1835_
1836_
1837_
1838_
1839_
1840_
1841_
1842_
1843_
1844_
1845_
1846_
1847_
1848_
1849_
1850_
1851_
1852_
1853_
1854_

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
6G1
7G1
12G1
18G1
25G1
34G1
41G1
2x1,5
3G1,5
4G1,5
5G1,5
6G1,5
7G1,5
12G1,5
18G1,5
25G1,5
34G1,5
41G1,5

Outer
Cop.
approx. mm weight
kg/km
6,8
19,2
7,2
29,0
7,8
38,0
8,8
48,0
9,6
58,0
10,5
67,0
13,0
115,0
15,1
173,0
18,7
240,0
21,6
326,0
23,2
394,0
8,3
29,0
8,8
43,0
9,9
58,0
10,8
72,0
11,9
86,0
12,9
101,0
14,7
173,0
17,9
259,0
20,8
360,0
24,9
490,0
26,7
590,0

Weight
approx.
kg/km
59,0
70,0
87,0
100,0
131,0
182,0
230,0
325,0
476,0
616,0
724,0
92,0
108,0
144,0
168,0
201,0
230,0
306,0
464,0
641,0
857,0
1010,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16


Part no.
1855_
1856_
1857_
1858_
1859_
1860_
1861_
1862_
1863_
1864_
1865_
1866_
1867_
1868_
1869_
1870_
1871_
1872_
1873_
1874_
1875_
1876_

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
2x4
3G4
4G4
5G4
7G4
2x6
3G6
4G6
5G6
7G6
3G10
4G10
5G10
3G16
4G16
5G16

Outer
Cop.
approx. mm weight
kg/km
10,0
48,0
10,5
72,0
11,8
96,0
13,0
120,0
14,7
168,0
18,0
288,0
11,6
77,0
12,3
115,0
13,7
154,0
15,2
192,0
20,8
268,0
13,2
115,0
14,2
173,0
15,8
230,0
17,5
288,0
22,0
403,0
18,6
288,0
20,5
384,0
22,7
480,0
23,5
461,0
25,7
614,0
28,5
768,0

Weight
approx.
kg/km
120,0
148,0
184,0
224,0
301,0
489,0
149,0
240,0
297,0
360,0
540,0
240,0
370,0
472,0
581,0
698,0
560,0
718,0
896,0
940,0
1068,0
1810,0

AWG-No.
14
14
14
14
14
14
12
12
12
12
12
10
10
10
10
10
8
8
8
6
6
6

Dimensions and specifications may be changed without prior notice. (RA02)

Insulating, shrinking, braided and


temperature protection tubes
Braided hoses
High temperature protection
Insulation tubes
Heat-shrink tubes
End caps

You can nd insulating, shrinking, braided and temperature protection tubes


in our catalogue Cable Accessories.

A 50
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR-750

halogen-free, meter marking

Technical data

Cable structure

Properties

Special PUR cablesin adapted to


DINVDE0282 part10
Temperature range
flexing
-40 C to +80 C
(up to +100 C for short periods)
Nominal voltage
U0/U 300/500 V up to 1 mm
U0/U 450/750 V as of 1,5 mm
Test voltage
2000 V up to 1 mm
2500 V as of 1,5 mm
Insulation resistance
min. 20 MOhm x km
Tensile strength 20 N/mm (Cu)
Minimum bending radius
flexing 10xcable
fixed installation 5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
PUR core insulation
Colour coded to DINVDE0293-308 and as
of 6 cores number coded
For two cores: brown, blue
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
PUR outer jacket halogen-free
Sheath colour orange (RAL 2004)
with meter marking, change-over in 2011

High flexibility at low temperature


Usable for foodstuffs
High abrasion resistance
Resistant to
Oils and fats
Non-alcoholic fuels and kerosene
Atmospheric influences, UV-radiation
Oxygene and ozone
Microbes and rotting
Sea and waste water, vibrations
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Especially suited for installation in all areas demanding good performance under extreme conditions. These cable types have been successfully
in use in areas such as steel works, heating and air-conditioning systems, in machinery and industrial plant equipment and on building sites
etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
49700
49701
49702
49703
49704
49705
49706
49707
49708
49709
49710
49711
49712
49713
49714
49715
49716
49717
49718
49719
49720
49721
49722
49723
49724
49725
49726
49727
49728
49729
49730
49731
49732
49733
49734
49735
49736
49737
49738

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75
2x1
3G1
4G1
5G1
6G1
7G1
8G1
10G1
12G1
16G1
18G1
20G1
25G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
10G1,5
12G1,5
16G1,5
18G1,5
20G1,5
25G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
16G2,5

Outer
Cop.
approx. mm weight
kg/km
6,3
15,0
6,8
22,0
7,4
29,0
8,3
36,0
9,7
50,0
12,1
86,0
14,2
130,0
17,6
180,0
6,8
20,0
7,2
29,0
7,8
38,0
8,7
48,0
9,5
58,0
10,2
67,0
11,2
77,0
12,6
96,0
12,8
115,0
14,3
154,0
15,3
173,0
16,2
192,0
18,8
240,0
8,2
29,0
8,7
43,0
9,7
58,0
10,6
72,0
12,8
101,0
15,5
150,0
15,8
172,0
17,9
230,0
19,0
259,0
20,0
300,0
23,5
360,0
9,8
48,0
10,5
72,0
11,6
96,0
13,0
120,0
15,5
168,0
19,3
288,0
21,6
394,0

Weight
approx.
kg/km
44,0
55,0
70,0
91,0
130,0
192,0
290,0
405,0
50,0
65,0
87,0
106,0
135,0
160,0
185,0
210,0
240,0
310,0
353,0
390,0
495,0
70,0
95,0
120,0
164,0
210,0
290,0
340,0
440,0
508,0
560,0
722,0
110,0
150,0
180,0
240,0
340,0
520,0
680,0

AWG-No.
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14


Part no.
49739
49740
49741
49742
49743
49744
49745
49746
49747
49748
49749
49750
49751
49752
49753
49754
49755
49756
49757
49758
49759
49760
49761
49918
49762
49763

No.cores x
cross-sec.
mm
18G2,5
20G2,5
25G2,5
3G4
4G4
5G4
7G4
4G6
5G6
7G6
4G10
5G10
7G10
4G16
5G16
4G25
5G25
4G35
5G35
4G50
5G50
4G70
5G70
4G95
5G95
4G120

Outer
Cop.
approx. mm weight
kg/km
23,0
432,0
24,4
480,0
28,5
600,0
12,2
115,0
13,4
154,0
15,1
192,0
18,2
269,0
15,8
230,0
17,5
288,0
21,0
403,0
20,6
384,0
22,7
480,0
26,6
672,0
23,6
614,0
26,2
768,0
29,4
960,0
32,7
1200,0
33,1
1344,0
36,8
1680,0
38,4
1920,0
43,0
2400,0
44,0
2688,0
49,5
3660,0
51,2
3648,0
57,5
4560,0
55,0
4610,0

Weight
approx.
kg/km
778,0
860,0
1083,0
220,0
280,0
350,0
470,0
400,0
500,0
700,0
640,0
800,0
1180,0
920,0
1180,0
1400,0
1740,0
1870,0
2320,0
2700,0
3300,0
3700,0
4900,0
4850,0
6000,0
6005,0

AWG-No.
14
14
14
12
12
12
12
10
10
10
8
8
8
6
6
4
4
2
2
1
1
2/0
2/0
3/0
3/0
4/0

Dimensions and specifications may be changed without prior notice. (RA02)

A 51
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ 500-FC-PUR

EMC-preferred type, tear and coolant resistant, screened,

without inner sheath, meter marking

Technical data

Cable structure

Properties

Special polyurethane sheathed cable


adapted to DINVDE0245 part201 to
1,5mm,
adapted to DINVDE0245 part102 from
2,5mm
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Breakdown voltage
min. 6000 V
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper conductor, fine wire to


DINVDE0295 cl.5, BS6360 cl.5 and/or
IEC60228 cl.5
Core insulation of special PVCTI2 to
DINVDE0281, part1
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Separating foil
Tinned copper braided screening, coverage
approx. 85%
Core wrapping from fleece guarantees
good stripping capability
Outer sheath from special full
polyurethane TMPU acc. to DIN EN
50363-10-2  
Sheath colour grey (RAL 7001)
Also available in other sheath colours
with meter marking, change-over in 2011


Resistant to
UV-radiation, Oxygen, Ozone, Hydrolyse
and Microbes
Low adhesion, matt surface
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
unscreened analogue type:
JZ-500-PUR, see pageA43

Application
Extremely robust cable noted for its good abrasion resistance and notch resistance. Due to its resistance to coolant emulsions, this cable
is well suited for use in mechanical engineering, tool making, and systems engineering, and in steel mills and rolling mills in particularly
critical areas. Good flexibility means that installation is quick and easy. Suitable for medium mechanical stresses with free movement without
tensile stress or forced movements in dry, moist and wet rooms, and in open air (fixed installation). The dense screening assures
interference-free transmission of all signals and impulses. An ideal interference-free control cable for the above applications.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
23414
23416
23415
23418
23417
23419
23420
23422
23421
23423
23424
23425
23426
23427
23428

No.cores x
cross-sec.
mm
2x0,5
3x0,5
3G0,5
4x0,5
4G0,5
5G0,5
5x0,5
7x0,5
7G0,5
10G0,5
12G0,5
18G0,5
25G0,5
34G0,5
42G0,5

Outer
Cop.
approx. mm weight
kg/km
5,7
35,0
5,9
42,0
5,9
42,0
6,4
47,0
6,4
47,0
6,9
56,0
6,9
56,0
7,6
69,0
7,6
69,0
9,6
94,0
9,7
108,0
11,5
145,0
13,6
240,0
15,6
312,0
17,0
355,0

Weight
approx.
kg/km
47,0
57,0
57,0
60,0
60,0
75,0
75,0
97,0
97,0
133,0
158,0
218,0
315,0
420,0
487,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20


Part no.
23429
23430
23431
23432
23433
23434
23435
23436
23437
23438
23439
23440
23441
23442
23443

No.cores x
cross-sec.
mm
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
7G0,75
7x0,75
10G0,75
12G0,75
18G0,75
25G0,75
34G0,75
42G0,75

Outer
Cop.
approx. mm weight
kg/km
6,1
40,0
6,3
52,0
6,3
52,0
6,8
60,0
6,8
60,0
7,4
71,0
7,4
71,0
8,2
91,0
8,2
91,0
10,3
137,0
10,5
142,0
12,7
212,0
15,0
281,0
17,2
345,0
18,6
407,0

Weight
approx.
kg/km
60,0
67,0
67,0
76,0
76,0
92,0
92,0
131,0
131,0
180,0
204,0
290,0
413,0
492,0
624,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18

Continuation

A 52
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ 500-FC-PUR

EMC-preferred type, tear and coolant resistant, screened,

without inner sheath, meter marking

Part no.
23444
23446
23445
23447
23448
23449
23450
23451
23452
23453
23454
23455
23456
23457
23458
23459
23460
23462
23461
23464
23463
23465
23466
23468
23467
23469
23470
23471
23472

No.cores x
cross-sec.
mm
2x1
3x1
3G1
4G1
4x1
5G1
5x1
7G1
7x1
10G1
12G1
18G1
25G1
34G1
42G1
50G1
2x1,5
3x1,5
3G1,5
4x1,5
4G1,5
5G1,5
5x1,5
7x1,5
7G1,5
12G1,5
18G1,5
25G1,5
30G1,5

Outer
Cop.
approx. mm weight
kg/km
6,4
50,0
6,7
60,0
6,7
60,0
7,2
71,0
7,2
71,0
8,0
88,0
8,0
88,0
8,7
111,0
8,7
111,0
11,2
150,0
11,4
184,0
13,5
260,0
16,2
349,0
18,5
486,0
20,2
545,0
21,8
625,0
7,0
63,0
7,4
80,0
7,4
80,0
8,1
97,0
8,1
97,0
9,0
119,0
9,0
119,0
9,8
147,0
9,8
147,0
12,8
267,0
15,5
374,0
18,5
526,0
19,6
555,0

Weight
approx.
kg/km
66,0
82,0
82,0
100,0
100,0
128,0
128,0
157,0
157,0
230,0
262,0
381,0
535,0
740,0
867,0
1027,0
87,0
102,0
102,0
127,0
127,0
159,0
159,0
207,0
207,0
340,0
480,0
704,0
817,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16


Part no.
23473
23474
23475
23476
23477
23478
23479
23480
23481
23482
23483
23484
23485
23486
23487
23488

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
4G4
5G4
7G4
4G6
5G6
7G6
4G10
5G10
7G10
4G16

Outer
Cop.
approx. mm weight
kg/km
8,4
96,0
8,8
144,0
9,8
148,0
10,8
181,0
11,9
255,0
15,8
441,0
11,6
230,0
12,9
273,0
14,2
316,0
13,8
305,0
15,3
439,0
16,9
505,0
17,1
535,0
19,1
592,0
21,2
810,0
20,0
740,0

Weight
approx.
kg/km
131,0
168,0
194,0
222,0
345,0
570,0
310,0
386,0
498,0
414,0
510,0
673,0
591,0
768,0
976,0
1196,0

AWG-No.
14
14
14
14
14
14
12
12
12
10
10
10
8
8
8
6

Dimensions and specifications may be changed without prior notice. (RA02)

A 53
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

F-C-PUR-JZ

tear and coolant resistant, Cu-screened, without inner sheath,

increased oil resistant, EMC-preferred type, meter marking

Technical data

Cable structure

Special polyurethane-sheathed multicore


cable on the basis of DINVDE0245
part201 up to 1,5mm, on the basis of
DINVDE0245 part102 as of 2,5mm
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Coupling resistance
max. 250 Ohm/km

Plain copper conductor, finely stranded,


according to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Oil resistant PVC core insulation TI2, in
adapted to DINVDE0281 part1, for better
sliding abilities
Cores black with sequential numbering
imprinted in white according to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Separating foil
Braided screen of tinned Cu wires,
coverage approx. 85%
Fleece separator, ensure good dismantling
ability
Special full-polyurethane outer jacket
TMPU, to DIN EN 50363-10-2  
Sheath colour grey (RAL 7001)
Outer jacket also available in other colours
with meter marking, change-over in 2011

Properties

Resistant to
UV-Radiation
Oxygene
Ozone and hydrolysis
Microbes
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
PUR-JZ, see pageA44

Application
Extremely robust control cable characterised by high abrasion and notch resistance properties. Used for critical areas in such applications
as machinery, tooling and plant construction, in rolling mills and steel works because of the resistance to mineral oils and to coolant emulsions
in particular. Rapid and safe installation assured by the good flexibility of the cable. Suitable for outdoor installation.
An interference-free transmission of signals and pulses is assured by the high screening density. The ideal interference-protected control
cable for such applications as given above.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
21200
21201
21202
21203
21205
21207
21208
21209
21211
21213
21215
21217
21220
21221
21224

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
10G0,5
12G0,5
14G0,5
18G0,5
21G0,5
25G0,5
30G0,5
36G0,5
40G0,5
50G0,5

Outer
Cop.
approx. mm weight
kg/km
5,7
35,0
5,9
42,0
6,4
47,0
6,9
56,0
7,6
69,0
9,6
94,0
9,7
108,0
10,2
116,0
11,5
145,0
12,7
188,0
13,6
240,0
14,4
295,0
15,6
318,0
16,9
343,0
18,5
406,0

Weight
approx.
kg/km
44,0
56,0
60,0
75,0
97,0
133,0
158,0
190,0
218,0
252,0
315,0
362,0
447,0
475,0
572,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20


Part no.
21227
21228
21229
21230
21232
21234
21235
21236
21238
21240
21242
21245
21249
21251

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
10G0,75
12G0,75
14G0,75
18G0,75
21G0,75
25G0,75
32G0,75
41G0,75
50G0,75

Outer
Cop.
approx. mm weight
kg/km
6,1
40,0
6,3
52,0
6,8
60,0
7,4
71,0
8,2
91,0
10,3
137,0
10,5
142,0
11,3
180,0
12,7
212,0
14,0
246,0
15,0
281,0
16,7
342,0
18,6
400,0
20,3
461,0

Weight
approx.
kg/km
60,0
67,0
76,0
92,0
131,0
180,0
204,0
226,0
290,0
376,0
413,0
485,0
611,0
775,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18

Continuation

A 54
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

F-C-PUR-JZ

tear and coolant resistant, Cu-screened, without inner sheath,

increased oil resistant, EMC-preferred type, meter marking

Part no.
21253
21254
21255
21256
21257
21258
21259
21261
21262
21263
21264
21265
21267
21268
21273
21276
21278
21280
21281
21282
21283
21285
21286
21287
21288

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
6G1
7G1
8G1
10G1
12G1
14G1
16G1
18G1
21G1
25G1
34G1
41G1
50G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5

Outer
Cop.
approx. mm weight
kg/km
6,4
50,0
6,7
60,0
7,2
71,0
8,0
88,0
8,7
97,0
8,7
111,0
10,1
127,0
11,2
150,0
11,4
184,0
12,0
196,0
12,8
209,0
13,5
260,0
14,3
319,0
16,2
349,0
18,5
486,0
19,9
531,0
21,8
625,0
7,0
63,0
7,4
80,0
8,1
97,0
9,0
119,0
9,8
147,0
10,5
170,0
12,6
193,0
12,8
267,0

Weight
approx.
kg/km
66,0
82,0
100,0
128,0
145,0
157,0
198,0
230,0
262,0
302,0
345,0
381,0
480,0
535,0
740,0
855,0
1027,0
87,0
102,0
127,0
159,0
207,0
245,0
313,0
340,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16

Part no.
21290
21291
21292
21295
21296
21297
21298
21299
21300
21301
21302
21303
21304
21305
21306
21313
21314
21315
21316
21317
21319
21320
21321
21322

No.cores x
cross-sec.
mm
14G1,5
16G1,5
18G1,5
21G1,5
25G1,5
34G1,5
42G1,5
50G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
10G2,5
12G2,5
2x4
3G4
4G4
5G4
7G4
3G6
4G6
5G6
7G6

Outer
Cop.
approx. mm weight
kg/km
13,5
283,0
14,4
315,0
15,5
374,0
16,4
425,0
18,5
526,0
21,2
629,0
21,9
819,0
25,0
885,0
8,4
96,0
8,8
144,0
9,8
148,0
10,8
181,0
11,9
255,0
15,2
340,0
15,8
441,0
10,0
120,0
10,7
174,0
11,6
230,0
12,9
273,0
14,2
316,0
12,6
240,0
13,8
305,0
15,3
439,0
16,9
505,0

Weight
approx.
kg/km
384,0
425,0
480,0
563,0
704,0
870,0
1040,0
1292,0
131,0
168,0
194,0
222,0
345,0
462,0
570,0
187,0
243,0
310,0
386,0
498,0
333,0
414,0
510,0
673,0

AWG-No.
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
12
12
12
12
12
10
10
10
10

Dimensions and specifications may be changed without prior notice. (RA02)

A 55
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Y-C-PUR-JZ

tear and coolant resistant, Cu-screened, with inner sheath,

increased oil resistant, EMC-preferred type, meter marking

Technical data

Cable structure

Special polyurethane-sheathed multicore


cable on the basis of DINVDE0245
part202/03.92 up to1,5 mm, on the basis
of DINVDE0281 part13 as of 2,5mm
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
as of cross section 4 mm
U0/U 450/750 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Coupling resistance
max. 250 Ohm/km

Plain copper conductor, finely stranded,


according to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Oil resistant PVC core insulation TI2, in
adapted to DINVDE0281 part1, for better
sliding abilities
Cores black with sequential numbering
imprinted in white according to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Oil resistant PVC inner sheath
Sceen of tinned Cu braid, coverage approx.
85%
Fleece separator, ensure good dismantling
ability
Special full-polyurethane outer jacket
TMPU, to DIN EN 50363-10-2  
Sheath colour grey (RAL7001)
with meter marking, change-over in 2011

Properties

Resistant to
UV-Radiation
Oxygene
Ozone and hydrolysis
Microbes
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
PUR-JZ, see pageA44

Application
Extremely robust control cable characterised by high abrasion and notch resistance properties. Used for critical areas in such applications
as machinery, tooling and plant construction, in rolling mills and steel works because of the resistance to mineral oils and to coolant emulsions
in particular. The mechanical strength of the cable is increased by the additional oil-resistant inner sheath. The ideal interference-protected
control cable for such applications as given above. Suitable for outdoor installation.
These screened cables are particularly suitable for the interference-free transmission in instrumentation and control engineering applications
(electromagnetic compatibility).
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
21400
21401
21402
21403
21405
21407
21408
21409
21411
21413
21415
21416
21419
21420
21421

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
10G0,5
12G0,5
14G0,5
18G0,5
21G0,5
25G0,5
30G0,5
36G0,5
40G0,5
50G0,5

Outer
Cop.
approx. mm weight
kg/km
6,6
41,0
7,1
45,0
7,6
54,0
8,2
66,0
9,4
79,0
11,2
107,0
11,3
137,0
11,9
142,0
12,9
156,0
14,7
189,0
15,9
250,0
16,2
297,0
17,8
320,0
19,1
345,0
20,9
407,0

Weight
approx.
kg/km
68,0
84,0
95,0
107,0
135,0
170,0
195,0
222,0
278,0
330,0
406,0
520,0
587,0
655,0
742,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20


Part no.
21425
21426
21427
21428
21430
21432
21433
21434
21436
21438
21440
21443
21446
21447

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
10G0,75
12G0,75
14G0,75
18G0,75
21G0,75
25G0,75
32G0,75
41G0,75
50G0,75

Outer
Cop.
approx. mm weight
kg/km
7,2
46,0
7,7
57,0
8,2
63,0
8,8
76,0
10,1
100,0
12,2
140,0
12,3
175,0
13,0
190,0
14,6
240,0
16,0
274,0
17,8
306,0
18,7
349,0
21,5
403,0
23,1
470,0

Weight
approx.
kg/km
88,0
98,0
112,0
130,0
185,0
270,0
294,0
317,0
357,0
455,0
510,0
688,0
951,0
1100,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18

Continuation

A 56
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Y-C-PUR-JZ

tear and coolant resistant, Cu-screened, with inner sheath,

increased oil resistant, EMC-preferred type, meter marking

Part no.
21451
21452
21453
21454
21456
21457
21458
21459
21460
21461
21462
21463
21465
21468
21469
21470
21474
21475
21476
21477
21479
21480
21481
21482
21483
21484
21485
21487
21489
21492
21494
21495
21499
21500
21501
21502
21503
21504

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
8G1
10G1
12G1
14G1
16G1
18G1
20G1
25G1
34G1
41G1
50G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5
14G1,5
16G1,5
18G1,5
21G1,5
25G1,5
34G1,5
42G1,5
50G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5

Outer
Cop.
approx. mm weight
kg/km
7,7
54,0
8,0
64,0
8,6
76,0
9,1
89,0
11,0
114,0
11,6
130,0
12,6
156,0
13,1
186,0
13,8
198,0
14,6
214,0
15,6
284,0
16,4
325,0
18,9
387,0
20,9
500,0
22,3
578,0
24,6
681,0
8,2
64,0
8,6
82,0
9,3
99,0
10,4
123,0
12,0
148,0
12,9
172,0
14,2
198,0
14,6
274,0
15,4
294,0
16,1
318,0
17,2
386,0
19,0
447,0
20,8
531,0
23,2
671,0
26,1
890,0
27,4
997,0
9,8
110,0
10,7
148,0
11,4
169,0
12,5
220,0
14,9
284,0
18,4
470,0

Weight
approx.
kg/km
98,0
102,0
145,0
170,0
220,0
270,0
330,0
350,0
402,0
420,0
515,0
545,0
690,0
912,0
1070,0
1318,0
130,0
152,0
167,0
203,0
305,0
335,0
422,0
435,0
480,0
525,0
642,0
722,0
803,0
1068,0
1370,0
1677,0
180,0
215,0
268,0
349,0
406,0
720,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14

Part no.
21507
21508
21509
21510
21511
21512
21513
21514
21515
21516
21517
21518
21519
21521
21522
21524
21525
21526
21527
21528
21529
21530
21531
21532
21533
21534

No.cores x
cross-sec.
mm
2x4
3G4
4G4
5G4
7G4
3G6
4G6
5G6
7G6
3G10
4G10
5G10
7G10
4G16
5G16
4G25
5G25
4G35
5G35
4G50
5G50
4G70
5G70
4G95
5G95
4G120

Outer
Cop.
approx. mm weight
kg/km
12,0
124,0
12,6
178,0
14,2
234,0
15,6
284,0
17,1
321,0
14,8
245,0
16,1
316,0
18,0
442,0
19,6
530,0
18,2
367,0
20,3
549,0
22,4
604,0
24,7
820,0
23,4
807,0
26,0
940,0
29,7
1169,0
33,0
1420,0
33,9
1680,0
37,5
2020,0
39,0
2370,0
43,4
2880,0
46,6
3257,0
51,1
4032,0
50,9
4060,0
55,9
5244,0
55,5
5231,0

Weight
approx.
kg/km
300,0
340,0
408,0
504,0
640,0
453,0
560,0
700,0
905,0
750,0
1023,0
1114,0
1505,0
1385,0
1550,0
1894,0
2272,0
2395,0
2890,0
3312,0
4100,0
4605,0
5710,0
6055,0
7520,0
7318,0

AWG-No.
12
12
12
12
12
10
10
10
10
8
8
8
8
6
6
4
4
2
2
1
1
2/0
2/0
3/0
3/0
4/0

Dimensions and specifications may be changed without prior notice. (RA02)

A 57
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

UNIPUR-CP

flexible at low temperature, with customer markings, halogen-free,

wear resistant, robust, screened, EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Special TPE/PUR screened connecting cable


adapted to DINVDE0282 part10
Temperature range
flexing-40 C to +90 C
Nominal voltage
up to 1 mm U0/U 300/500 V
above 1,5 mm U0/U 450/750 V
Test voltage 3000 V
Minimum bending radius
flexing 12,5x cable
fixed installation 7,5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, fine wire conductors bunch


stranded according to DINVDE0295 cl.5,
BS6360 cl.5 and IEC60228 cl.5
Core insulation of termoplastic elastomere
(TPE)
Core colours according DINVDE0293-308
Core colour:
- up to 5 cores one-coloured
- up 6 and more cores, black with white
numbering
- up 3 and above, with green-yellow earth
core
- 2 cores without green-yellow earth core
Cores stranded in layers with optimal
lay-length
Core wrapping with foil
Tinned copper braided screening, coverage
approx. 85%
PUR outer sheath TMPU in adapted to DIN
EN 50363-10-2
Jacket colour by request
with meter marking, change-over in 2011

Flame retardant according to


VDE0482-332-1-2, DIN EN60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Resistant to
Oils and fats
Water and weathering effects
Ozone and oxygen
UV-radiation
Hydrolysis
Microbial attack
Abrasion resistant
Notch resistant
Resistant to tearing and cutting
Good flexibility at low temperatures down
to -40 C
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers



Note

G = with green-yellow earth core;


x = without green-yellow earth core (OB).
Colour code:
0 = RAL 5015, blue
1 = RAL 6018, green
2 = RAL 8003, brown
3 = RAL 1021, yellow
4 = RAL 3000, red
5 = RAL 2003, orange
6 = RAL 4005, violet
7 = RAL 7001/7032, grey
Please add the individual part no. for order
with the identification colour code.
Further colours on request.
unscreened analogue type:
UNIPUR, see pageA49

Application
These robust and flexible cables are used for electrical tools such as drills, hand-held circular saws, and garden equipment as well as for
portable motors and machinery in agriculture, at building sites, for hobbies, docks and refrigeration plants.
Extremely good mechanical characteristies e.g. compressive load, good abrasion and near-resistant.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
1915_
1916_
1917_
1918_
1919_
1920_
1921_
1922_
1923_
1924_

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5
34G0,5
41G0,5

Outer
Cop.
approx. mm weight
kg/km
6,1
35,0
6,3
42,0
6,8
47,0
7,4
56,0
8,8
69,0
10,9
108,0
13,0
145,0
15,6
240,0
17,2
312,0
19,4
348,0

Weight
approx.
kg/km
46,0
56,0
62,0
75,0
98,0
158,0
216,0
315,0
371,0
442,0

AWG-No.
20
20
20
20
20
20
20
20
20
20


Part no.
1925_
1926_
1927_
1928_
1929_
1930_
1931_
1932_
1933_
1934_
1935_

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
6G0,75
7G0,75
12G0,75
18G0,75
25G0,75
34G0,75
41G0,75

Outer
Cop.
approx. mm weight
kg/km
6,8
40,0
7,1
52,0
7,7
60,0
8,4
71,0
9,1
80,0
10,0
91,0
12,3
142,0
14,8
212,0
18,4
281,0
20,3
345,0
22,0
400,0

Weight
approx.
kg/km
60,0
68,0
78,0
95,0
112,0
138,0
207,0
293,0
413,0
523,0
609,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18

Continuation

A 58
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

UNIPUR-CP

flexible at low temperature, with customer markings, halogen-free,

wear resistant, robust, screened, EMC-preferred type, meter marking

Part no.
1936_
1937_
1938_
1939_
1940_
1941_
1942_
1943_
1944_
1945_
1946_
1947_
1948_
1949_
1950_
1951_
1952_
1953_
1954_
1955_
1956_
1957_

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
6G1
7G1
12G1
18G1
25G1
34G1
41G1
2x1,5
3G1,5
4G1,5
5G1,5
6G1,5
7G1,5
12G1,5
18G1,5
25G1,5
34G1,5
41G1,5

Outer
Cop.
approx. mm weight
kg/km
7,1
50,0
7,4
60,0
8,1
71,0
8,8
88,0
9,7
97,0
10,7
111,0
12,9
184,0
15,7
260,0
19,3
349,0
21,6
486,0
23,3
531,0
8,4
63,0
8,8
80,0
9,8
97,0
10,9
119,0
12,1
121,0
13,2
147,0
16,5
267,0
19,6
374,0
24,2
526,0
27,0
629,0
29,3
801,0

Weight
approx.
kg/km
65,0
76,0
89,0
108,0
141,0
187,0
240,0
335,0
484,0
627,0
738,0
97,0
119,0
152,0
168,0
218,0
243,0
317,0
481,0
674,0
881,0
1027,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16

Part no.
1958_
1959_
1960_
1961_
1962_
1963_
1964_
1965_
1966_
1967_
1968_
1969_
1970_
1971_
1972_
1973_
1974_
1975_
1976_
1977_
1978_
1979_

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
2x4
3G4
4G4
5G4
7G4
2x6
3G6
4G6
5G6
7G6
3G10
4G10
5G10
3G16
4G16
5G16

Outer
Cop.
approx. mm weight
kg/km
10,0
96,0
10,7
144,0
11,9
148,0
13,2
181,0
16,0
255,0
19,8
441,0
11,8
120,0
12,4
174,0
13,8
230,0
15,6
273,0
18,9
316,0
13,4
173,0
14,3
240,0
16,0
305,0
17,9
439,0
21,6
505,0
18,1
350,0
20,2
535,0
22,5
592,0
20,6
585,0
23,0
740,0
25,6
895,0

Weight
approx.
kg/km
129,0
158,0
196,0
241,0
317,0
496,0
158,0
261,0
316,0
384,0
592,0
259,0
394,0
483,0
592,0
714,0
576,0
729,0
914,0
960,0
1813,0
1827,0

AWG-No.
14
14
14
14
14
14
12
12
12
12
12
10
10
10
10
10
8
8
8
6
6
6

Dimensions and specifications may be changed without prior notice. (RA02)

Terminations and straight-through joints


Telephone calbes
Low voltage
Medium voltage
Accessories

You can nd terminations and straight-through joints in our catalogue Cable Accessories.

A 59
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR-C-PUR Cu-screened, extrem conditions, halogen-free, EMC-preferred type, meter


marking

Technical data

Cable structure

Properties

Special PUR control cables, screened,


adapted to DINVDE0250
Temperature range
-40 C to +80 C
Nominal voltage
U0/U 300/500 V until 1 mm
U0/U 450/750 V from 1,5 mm
Test voltage
until 1 mm 2000 V
from 1,5 mm 2500 V
Insulation resistance
min. 20 MOhm x km
Mutual capacitance (800 Hz)
core/core approx. 150 pF/m
core/screen approx. 320 pF/m
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Special PUR insulation
Core identification according to
DINVDE0293-308
Green-yellow earth core (3 cores and above)
Cores stranded in layers with optimal
lay-length
Foil taped
Copper braided screening with 80-85%
coverage
PUR outer jacket
Colour grey (RAL7032)
with meter marking, change-over in 2011

High flexibility at low temperatures


High abrasion resistance
Break and cut resistant
Tear resistant
Resistant to
Oils and fats
Coolant and chemicals
Non-alcoholic fuels and kerosene
Atmospheric influences
UV-radiation
Oxygene and ozone
Microbes and rotting
Sea and waste water
Vibrations
Acids and Lyes
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (O).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
PUR-C-PUR screened cables are well suited as data transfer and connection cables for the machine and motor industries due to the good
level of copper screening which blocks strong electrical disturbances.
This cable type has proven to be especially suited to use in extreme weather and environmental conditions due to its good thermal and
chemical properties. (Temperature range -40 C to +80 C). In addition to this it also possesses excellent mechanical properties, e.g. pressure
resistance and good abrasive resistant qualities, all of which go to guarantee a long life.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
22315
22316
22317
22318
22319
22339
22340
22341
22342

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
6G0,75
2x1
3G1
4G1
5G1

Outer
Cop.
approx. mm weight
kg/km
6,8
40,0
7,4
52,0
8,0
60,0
8,8
71,0
9,5
80,0
7,3
50,0
7,7
60,0
8,3
71,0
9,2
88,0

Weight
approx.
kg/km
65,0
80,0
95,0
126,0
150,0
80,0
95,0
106,0
149,0

AWG-No.
18
18
18
18
18
17
17
17
17


Part no.
22364
22365
22366
22367
22385
22386
22387
22388

No.cores x
cross-sec.
mm
2x1,5
3G1,5
4G1,5
5G1,5
2x2,5
3G2,5
4G2,5
5G2,5

Outer
Cop.
approx. mm weight
kg/km
8,8
63,0
9,3
80,0
10,3
97,0
11,2
119,0
10,2
96,0
10,8
144,0
12,0
148,0
13,2
181,0

Weight
approx.
kg/km
101,0
125,0
150,0
210,0
142,0
169,0
225,0
275,0

AWG-No.
16
16
16
16
14
14
14
14

Dimensions and specifications may be changed without prior notice. (RA02)

A 60
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-500 HMH
MEGAFLEX 500
JZ-600 HMH
JB-750 HMH
(H)03 Z1Z1-F
(H)05 Z1Z1-F
JZ-500 HMH-C
MEGAFLEX 500-C
JZ-600 HMH-C
JB-750 HMH-C
Photo: HELUKABEL

Halogen-free Control Cables


In all locations, due to damages of large amount
of materials and more of importance to protect
human life and technical equipment against
damages caused by re and also for technical
enquiries of insurance, the installation of
halogen-free security cables are required.
You will nd on the following pages the
instructions for installation as well as the test
methods and laying instructions for the halogenfree security cables.

The most important advantages:


No re propagation from point of re
Functionallity for important systems
No corrosion and damage caused by released
corrosive gases and vapours
Protection of human life and valuable materials,
especially for high quality machines, EDP
systems etc.
Prevention of heavy and unexpected
subsequent damages
Low smoke density helps rescue and re
extinguishing

A 61
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-500 HMH

flexible control cable, halogen-free, extremely fire resistant,

oil resistant1), meter marking

Technical data

Cable structure

Properties

Halogen-free flexible control cable, core


construction adapted to DINVDE0281
part14 and DINVDE0281 part13
Temperature range
flexing -15 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage U0/U 300/500 V
Test voltage 2000 V
Minimum bending radius
flexing approx. 12,5x cable
fixed installation approx. 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of halogen-free compound
TI6, to EDINVDE0281 part14
Black cores with white continuous
numbering to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layer with optimal
lay-length
Halogen-free sheath compound TM7, to
EDINVDE0281 part14
Outer jacket colour grey (RAL7001)
with meter marking, change-over in 2011
LS0H = Low Smoke Zero Halogen-free.


) For the critical applications we advise for


consultation
The materials used in manufacture are
cadmium-free and containno siliconeand
free from substances harmful to the
wetting properties of lacquers

Tests
Flame test to VDE0482-332-3, BS4066
part3/ DINEN60332-3/ IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Halogen-free according to VDE0482
part267/ DINEN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
(equivalent DINVDE0472 part816)


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
Please note the cleanroom qualification
when ordering.
screened analogue type:
JZ-500 HMH-C, see pageA71

Application
Halogen-free, flame retardant cables are used as measuring and control cable in machine tools, conveyor belts, production lines as well as
in plant installations, in air-conditioning and steel production works. For fixed installation or flexible application, directed without forcing by
casual, not constantly recurring free movements and without tensile stress, for medium mechanical strain. This cable is suitable for the
application in dry, damp and wet environments and also for laying on, in and under plaster as well as in concrete and masonry excluding in
direct laying in shaked or stamped concrete, not suitable for imbedding in solidified or compressed concrete.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
11201
11202
11332
11203
11333
11204
11334
11205
11206
11207
11208
11209

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4G0,5
4x0,5
5G0,5
5x0,5
7G0,5
8G0,5
10G0,5
12G0,5
16G0,5

Outer
Cop.
approx. mm weight
kg/km
4,9
9,6
5,2
14,4
5,2
14,4
5,6
19,0
5,6
19,0
6,3
24,0
6,3
24,0
6,9
33,6
7,4
38,0
8,3
48,0
8,8
58,0
10,2
76,0

Weight
approx.
kg/km
43,0
50,0
50,0
60,0
60,0
71,0
71,0
84,0
101,0
121,0
142,0
183,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20


Part no.
11210
11211
11212
11213
11214
11215
11216
11217
11218
11219
11220

No.cores x
cross-sec.
mm
18G0,5
20G0,5
25G0,5
30G0,5
34G0,5
37G0,5
41G0,5
42G0,5
50G0,5
61G0,5
65G0,5

Outer
Cop.
approx. mm weight
kg/km
11,0
86,0
11,5
96,0
12,9
120,0
13,8
144,0
14,9
163,0
14,9
178,0
16,1
197,0
16,1
202,0
17,9
240,0
19,0
293,0
19,7
312,0

Weight
approx.
kg/km
204,0
227,0
283,0
324,0
367,0
381,0
417,0
454,0
519,0
635,0
694,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20

Continuation

A 62
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-500 HMH

flexible control cable, halogen-free, extremely fire resistant,

oil resistant1), meter marking




Part no.
11221
11222
11335
11223
11336
11224
11337
11225
11338
11226
11227
11228
11229
11230
11231
11232
11233
11234
11235
11236
11237
11238
11239
11240
11241
11242
11339
11243
11340
11244
11245
11246
11247
11248
11249
11250
11251
11252
11253
11254
11255
11256
11257
11258
11259
11260
11261
11341
11262
11263
11264
11265
11266
11267
11268
11269
11270
11271
11272
11273
11274
11275
11276

No.cores x
cross-sec.
mm
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
7G0,75
7x0,75
8G0,75
10G0,75
12G0,75
16G0,75
18G0,75
20G0,75
25G0,75
30G0,75
34G0,75
37G0,75
41G0,75
42G0,75
50G0,75
61G0,75
65G0,75
2x1
3G1
3x1
4G1
4x1
5G1
7G1
8G1
10G1
12G1
16G1
18G1
20G1
25G1
34G1
37G1
41G1
42G1
50G1
61G1
65G1
2x1,5
3G1,5
3x1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5
16G1,5
18G1,5
20G1,5
25G1,5
34G1,5
37G1,5
50G1,5
61G1,5
65G1,5

Outer
Cop.
approx. mm weight
kg/km
5,3
14,4
5,6
21,6
5,6
21,6
6,3
29,0
6,3
29,0
6,9
36,0
6,9
36,0
7,5
50,0
7,5
50,0
8,2
58,0
9,2
72,0
9,8
86,0
11,4
115,0
12,2
130,0
12,7
144,0
14,3
180,0
15,3
216,0
16,7
245,0
16,7
260,0
18,0
296,0
18,0
302,0
19,8
360,0
21,2
439,0
21,7
468,0
5,6
19,2
5,9
29,0
5,9
29,0
6,6
38,4
6,6
38,4
7,3
48,0
8,1
67,0
8,7
77,0
9,8
96,0
10,4
115,0
12,3
154,0
12,9
173,0
13,7
192,0
15,4
240,0
17,9
326,0
17,9
355,0
19,4
394,0
19,4
403,0
21,2
480,0
22,5
586,0
23,5
628,0
6,4
29,0
6,8
43,0
6,8
43,0
7,4
58,0
8,3
72,0
9,2
101,0
9,9
115,0
10,9
144,0
12,0
173,0
13,9
230,0
14,6
259,0
15,5
288,0
17,4
360,0
20,2
490,0
20,2
533,0
24,2
720,0
25,8
878,0
26,7
936,0

Weight
approx.
kg/km
47,0
56,0
56,0
69,0
69,0
83,0
83,0
114,0
114,0
136,0
172,0
183,0
241,0
266,0
291,0
374,0
450,0
517,0
541,0
611,0
621,0
742,0
853,0
909,0
63,0
74,0
74,0
90,0
90,0
109,0
151,0
184,0
224,0
243,0
314,0
361,0
387,0
496,0
670,0
713,0
784,0
824,0
952,0
1140,0
1201,0
70,0
94,0
94,0
112,0
141,0
191,0
224,0
282,0
311,0
392,0
450,0
497,0
630,0
842,0
897,0
1277,0
1460,0
1612,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16


Part no.
11277
11278
11279
11280
11281
11282
11283
11284
11285
11286
11287
11288
11289
11290
11291
11292
11293
11294
11295
11296
11297
11298
11299
11300
11301
11302
11303
11304
11305
11306
11307
11308
11309
11310
11311
11312
11313
11314
11315
11316
11317
11318
11319
11320
11321
11322
11323
11324
11325
11326
11327
11328
11329
11330
11331

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
8G2,5
10G2,5
12G2,5
16G2,5
18G2,5
20G2,5
25G2,5
30G2,5
2x4
3G4
4G4
5G4
7G4
8G4
10G4
12G4
16G4
18G4
2x6
3G6
4G6
5G6
7G6
2x10
3G10
4G10
5G10
7G10
2x16
3G16
4G16
5G16
7G16
3G25
4G25
5G25
3G35
4G35
5G35
3G50
4G50
5G50
3G70
4G70
5G70
3G95
4G95
5G95
3G120
4G120

Outer
Cop.
approx. mm weight
kg/km
7,8
48,0
8,3
72,0
9,2
96,0
10,1
120,0
11,2
168,0
12,3
192,0
13,9
240,0
14,8
288,0
17,1
384,0
18,2
432,0
19,1
480,0
21,6
600,0
23,0
720,0
9,3
77,0
9,8
115,0
11,0
154,0
12,3
192,0
13,6
269,0
14,6
307,0
17,8
384,0
18,2
461,0
20,6
614,0
21,9
691,0
11,0
115,0
11,9
173,0
13,0
230,0
14,5
288,0
16,2
403,0
14,0
192,0
14,8
288,0
16,4
384,0
18,3
480,0
20,2
672,0
16,8
307,0
18,2
461,0
20,0
614,0
22,6
768,0
24,8
1075,0
22,2
720,0
24,9
960,0
27,7
1200,0
25,6
1008,0
28,4
1344,0
31,7
1680,0
30,9
1440,0
34,2
1920,0
38,3
2400,0
36,5
2016,0
40,3
2688,0
45,3
3360,0
41,1
2736,0
45,8
3648,0
50,7
4560,0
47,0
3456,0
51,4
4608,0

Weight
approx.
kg/km
118,0
151,0
181,0
224,0
316,0
370,0
451,0
499,0
720,0
769,0
911,0
1047,0
1280,0
199,0
247,0
299,0
369,0
463,0
601,0
698,0
790,0
1130,0
1280,0
266,0
360,0
429,0
529,0
631,0
440,0
550,0
708,0
862,0
1124,0
642,0
830,0
1060,0
1270,0
1794,0
1190,0
1594,0
2014,0
1590,0
2200,0
2693,0
2571,0
3087,0
3980,0
3207,0
4077,0
5501,0
4708,0
5590,0
6972,0
5515,0
7100,0

AWG-No.
14
14
14
14
14
14
14
14
14
14
14
14
14
12
12
12
12
12
12
12
12
12
12
10
10
10
10
10
8
8
8
8
8
6
6
6
6
6
4
4
4
2
2
2
1
1
1
2/0
2/0
2/0
3/0
3/0
3/0
4/0
4/0

Dimensions and specifications may be changed without prior notice. (RA03)

Quality assurance inspections with the aid of


a stereo microscope at our Windsbach factory.

A 63
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MEGAFLEX 500

halogen-free, flame retardant, oil-resistant,

UV-resistant, flexible, meter marking

Technical data

Cable structure

Properties

Halogen-free flexible control cable,


core-structure adapted to DIN VDE 0281
part14, to UL-Style 20939, UL-Std. 758
Temperature range
flexing -30 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Minimum bending radius
flexing approx. 10x cable
fixed installation approx. 4x cable
Flexible
Alternate bending test according to DIN
VDE 0281-2

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of halogen-free special
polymer
Black cores with white continuous
numbering to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layer with optimal
lay-length
Outer sheath, halogen-free special polymer
Outer jacket colour grey (RAL7001)
with meter marking, change-over in 2011
The materials used in manufacture are
cadmium-free and contain no silicone and
are free from substances harmful to the
wetting properties of lacquers
 LS0H = Low Smoke Zero Halogen-free.

Halogen-free
Highly flame-retardant
Resistant to oils and greases
Resistant to UV and weathering
Hydrolysis resistant
Flexible, abrasion- and wear-resistant
Ozone-resistant
Recycleable
Tests
Flame test to VDE0482-332-3/ BS4066
part3/
DIN EN60332-3/ IEC60332-3-24 (previously
DINVDE0472 part804 test methodC)
Self-extinguishing and flame retardant
according to DINVDE0482-332-1-2, DIN
EN/IEC60332-1 (previously DINVDE0472
part804 test methodB)
Corrosiveness of combustion gases
according to NFX10-702
Halogen-free according to DINVDE0482
part267/ EN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to DINVDE0482
part1034-1+2, DINEN61034-1+2/
IEC61034-1+2, BS7622 part1+2 (previously
DINVDE0472 part816)
Oil-resistant to DIN EN 60811-2-1
Hydrolysis-resistant to DINEN61234-1
Ozone-resistant to DIN EN 60811-2-1 /
DIN VDE 0281-2


Approved to UL/CSA
see section N, page N 54

Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
Also available as a 0,6/1 kV cable under
consideration of economical minimum
quantities. MEGAFLEX 600
screened analogue type:
MEGAFLEX 500-C, see page A 73, N 56


Application
For fixed installation or flexible application, with free movements without forcing which do not constantly recur and without tensile stress,
for high mechanical strain.As a measuring and control cable primarily in machinery and plant contruction, in building and air-conditoning
systems, in warehousing and converying systems, in ship-building and for regenerative types of energy such as in the construction of wind
power stations. Especially well-suited for use in public buildings, such as airports and train stations, where personal injuries and subsequent
damage must be prevented in the event of a fire. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
13344
13345
13346
13347
13348
13349
13350
13351
13352
13353
13354
13355

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4G0,5
4x0,5
5G0,5
5x0,5
7G0,5
8G0,5
10G0,5
12G0,5
16G0,5

Outer
Cop.
approx. mm weight
kg/km
4,8
9,6
5,1
14,4
5,1
14,4
5,7
19,0
5,7
19,0
6,2
24,0
6,2
24,0
7,4
33,6
8,0
38,0
8,8
48,0
9,1
58,0
10,0
76,0

Weight
approx.
kg/km
43,0
50,0
50,0
60,0
60,0
71,0
71,0
84,0
101,0
121,0
142,0
183,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20


Part no.
13356
13357
13359
13360
13361
13362
13363
13364
13365
13366
13367

No.cores x
cross-sec.
mm
18G0,5
20G0,5
25G0,5
30G0,5
34G0,5
37G0,5
41G0,5
42G0,5
50G0,5
61G0,5
65G0,5

Outer
Cop.
approx. mm weight
kg/km
10,7
86,0
11,2
96,0
12,7
120,0
13,5
144,0
14,5
163,0
15,0
178,0
15,8
197,0
15,8
202,0
17,3
240,0
19,4
293,0
19,4
312,0

Weight
approx.
kg/km
204,0
227,0
283,0
324,0
367,0
381,0
417,0
454,0
519,0
635,0
694,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20

Continuation

A 64
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MEGAFLEX 500

halogen-free, flame retardant, oil-resistant,

UV-resistant, flexible, meter marking

Part no.
13368
13369
13370
13371
13372
13373
13374
13375
13376
13377
13378
13379
13380
13381
13382
13383
13384
13385
13386
13387
13388
13389
13390
13392
13393
13394
13395
13396
13397
13398
13399
13400
13401
13402
13403
13404
13405
13406
13407
13408
13409
13410
13411
13412
13413
13414
13415
13416
13417
13418
13419
13420
13421
13422
13423
13425
13426
13427
13428
13429
13430
13431
13432

No.cores x
cross-sec.
mm
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
7G0,75
7x0,75
8G0,75
10G0,75
12G0,75
16G0,75
18G0,75
20G0,75
25G0,75
30G0,75
34G0,75
37G0,75
41G0,75
42G0,75
50G0,75
61G0,75
65G0,75
2x1
3G1
3x1
4G1
4x1
5G1
7G1
8G1
10G1
12G1
16G1
18G1
20G1
25G1
34G1
37G1
41G1
42G1
50G1
61G1
65G1
2x1,5
3G1,5
3x1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5
16G1,5
18G1,5
20G1,5
25G1,5
34G1,5
37G1,5
50G1,5
61G1,5
65G1,5

Outer
Cop.
approx. mm weight
kg/km
5,2
14,4
5,5
21,6
5,5
21,6
6,2
29,0
6,2
29,0
6,8
36,0
6,8
36,0
8,1
50,0
8,1
50,0
8,9
58,0
9,6
72,0
9,9
86,0
11,2
115,0
11,9
130,0
12,6
144,0
14,1
180,0
15,4
216,0
16,4
245,0
17,2
260,0
17,6
296,0
17,6
302,0
19,8
360,0
20,9
439,0
21,5
468,0
5,5
19,2
6,0
29,0
6,0
29,0
6,6
38,4
6,6
38,4
7,2
48,0
8,6
67,0
9,4
77,0
10,4
96,0
10,7
115,0
12,0
154,0
12,7
173,0
13,5
192,0
15,2
240,0
17,4
326,0
18,4
355,0
18,9
394,0
18,9
403,0
21,0
480,0
22,2
586,0
22,8
628,0
6,1
29,0
6,5
43,0
6,5
43,0
7,2
58,0
7,9
72,0
9,5
101,0
10,4
115,0
11,3
144,0
11,7
173,0
13,3
230,0
14,0
259,0
14,9
288,0
16,8
360,0
19,4
490,0
20,2
533,0
23,4
720,0
24,8
878,0
26,0
936,0

Weight
approx.
kg/km
47,0
56,0
56,0
69,0
69,0
83,0
83,0
114,0
114,0
136,0
172,0
183,0
241,0
266,0
291,0
374,0
450,0
517,0
541,0
611,0
621,0
742,0
853,0
909,0
63,0
74,0
74,0
90,0
90,0
109,0
151,0
184,0
224,0
243,0
314,0
361,0
387,0
496,0
670,0
713,0
784,0
824,0
952,0
1140,0
1201,0
70,0
94,0
94,0
112,0
141,0
191,0
224,0
282,0
311,0
392,0
450,0
497,0
630,0
842,0
897,0
1277,0
1460,0
1612,0

AWG-No.
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16


Part no.
13433
13434
13435
13436
13437
13438
13439
13440
13441
13442
13443
13444
13445
13446
13447
13448
13449
13450
13451
13452
13453
13454
13455
13456
13457
13458
13459
13460
13461
13462
13463
13464
13465
13466
13467
13468
13469
13470
13471
13472
13473
13474
13475
13476
13477
13478
13479
13480
13481
13482
13483
13484
13485
13486
13487
13488
13489

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
8G2,5
10G2,5
12G2,5
16G2,5
18G2,5
20G2,5
25G2,5
30G2,5
2x4
3G4
4G4
5G4
7G4
8G4
10G4
12G4
16G4
18G4
2x6
3G6
4G6
5G6
7G6
2x10
3G10
4G10
5G10
7G10
2x16
3G16
4G16
5G16
7G16
3G25
4G25
5G25
3G35
4G35
5G35
3G50
4G50
5G50
3G70
4G70
5G70
3G95
4G95
5G95
3G120
4G120
3G150
4G150

Outer
Cop.
approx. mm weight
kg/km
7,6
48,0
8,3
72,0
9,1
96,0
10,2
120,0
12,1
168,0
13,2
192,0
14,6
240,0
15,2
288,0
16,8
384,0
18,1
432,0
19,0
480,0
22,2
600,0
22,9
720,0
9,2
77,0
9,9
115,0
11,0
154,0
12,1
192,0
13,3
269,0
15,9
307,0
17,3
384,0
18,3
461,0
20,2
614,0
21,8
691,0
10,8
115,0
11,7
173,0
13,0
230,0
14,5
288,0
16,0
403,0
14,0
192,0
15,0
288,0
16,8
384,0
18,7
480,0
20,6
672,0
16,5
307,0
17,6
461,0
19,7
641,0
21,9
768,0
24,4
1075,0
22,5
720,0
25,2
960,0
27,9
1200,0
26,3
1008,0
29,2
1344,0
32,7
1680,0
31,5
1440,0
35,0
1920,0
38,7
2400,0
37,2
2016,0
42,2
2688,0
47,4
3360,0
42,1
2736,0
47,0
3648,0
52,3
4560,0
46,6
3456,0
51,4
4608,0
53,0
4320,0
59,0
5760,0

Weight
approx.
kg/km
118,0
151,0
181,0
224,0
316,0
370,0
451,0
499,0
720,0
769,0
911,0
1047,0
1280,0
199,0
247,0
299,0
369,0
463,0
601,0
698,0
790,0
1130,0
1280,0
266,0
360,0
429,0
529,0
631,0
440,0
550,0
708,0
862,0
1124,0
642,0
830,0
1060,0
1270,0
1794,0
1190,0
1594,0
2014,0
1590,0
2200,0
2693,0
2571,0
3087,0
3980,0
3207,0
4077,0
5501,0
4708,0
5590,0
6972,0
5515,0
7100,0
6279,0
7781,0

AWG-No.
14
14
14
14
14
14
14
14
14
14
14
14
14
12
12
12
12
12
12
12
12
12
12
10
10
10
10
10
8
8
8
8
8
6
6
6
6
6
4
4
4
2
2
2
1
1
1
2/0
2/0
2/0
3/0
3/0
3/0
4/0
4/0
300 kcmil
300 kcmil

Dimensions and specifications may be changed without prior notice. (RA03)

A 65
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-600 HMH

flexible control cable, halogen-free, extremely fire resistant, oil

resistant1), 0,6/1kV, meter marking

Technical data

Cable structure

Properties

Halogen-free, flexible control cable,


adapted to DINVDE0281 part14 and
DINVDE0281 part13
Temperature range
flexing -15 C to +70 C
fixed -40 C to +70 C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4000 V
Minimum bending radius
for permanent bending
approx. 15x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductor to


DINVDE0295 cl.5, BS6360 cl.5 and/or
IEC60228 cl.5
Halogen-free polymer core insulation, TI6
acc. to EDINVDE0281 Part14
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Halogen-free polymer sheath, TM7 acc. to
EDINVDE0281 Part14
Sheath colour black (RAL9005)
with meter marking, change-over in 2011
LS0H = Low Smoke Zero Halogen-free.


) For critical applications recommend you


request a consultation
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Tests
Flame test acc. to VDE0482-332-3 BS4066
Part3/ DINEN60332-3/IEC60332-3 (as per
DINVDE0472 Part804 Test MethodC)
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Corrosiveness of corrosive gases acc. to
VDE0482, Part267/ DINEN50267-2-2/
IEC607542 (as per DINVDE0472, Part813)
Halogen-free acc. to VDE0482, Part267/
DINEN50267-2-1/ IEC60754-1 (as per
DINVDE0472, Part815)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
(equivalent DINVDE0472 part816)


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
screened analogue type:
JZ-600 HMH-C, see pageA75


Application
Halogen-free, flame retardant cables are used as measuring and control cable in machine tools, conveyor belts, production lines as well as
in plant installations, in heating and air-conditioning systems and steel production works. For fixed installation or flexible application, directed
without forcing by casual, constantly recurring free movements and without tensile stress, for medium mechanical strain. This cable is
suitable for the application in dry, damp and wet environments and outdoors (fixed installation) and for laying on, in and under plaster as
well as in concrete and masonry excluding in direct laying in vibration, compacted or compressed concrete.
EMC = Electromagnetic compatibillity
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
12723
12724
12725
12726
12727
12728
12729
12730
12731
12732
12733
12734

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4G0,5
4x0,5
5G0,5
5x0,5
7G0,5
10G0,5
12G0,5
18G0,5
25G0,5

Outer
Cop.
approx. mm weight
kg/km
6,3
9,6
6,6
14,4
6,6
14,4
7,2
19,0
7,2
19,0
8,0
24,0
8,0
24,0
8,7
33,6
10,6
48,0
11,4
58,0
13,8
86,0
16,1
120,0

Weight
approx.
kg/km
57,0
69,0
69,0
104,0
104,0
121,0
121,0
145,0
186,0
224,0
292,0
357,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20


Part no.
12735
12736
12737
12738
12739
12740
12741
12742
12743
12744
12745
12746

No.cores x
cross-sec.
mm
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
7G0,75
10G0,75
12G0,75
18G0,75
25G0,75

Outer
Cop.
approx. mm weight
kg/km
6,6
14,4
6,9
21,6
6,9
21,6
7,5
29,0
7,5
29,0
8,4
36,0
8,4
36,0
9,3
50,0
11,1
72,0
12,2
86,0
14,5
130,0
17,2
180,0

Weight
approx.
kg/km
68,0
77,0
77,0
136,0
136,0
152,0
152,0
208,0
250,0
271,0
387,0
498,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18

Continuation

A 66
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-600 HMH

flexible control cable, halogen-free, extremely fire resistant, oil

resistant1), 0,6/1kV, meter marking

Part no.
12747
12748
12749
12750
12751
12752
12753
12754
12755
12756
12757
12758
12759
12760
12761
12762
12763
12764
12765
12766
12767
12768
12769
12770
12771
12772
12773
12774
12775
12776
12777
12778
12779
12780
12781
12782

No.cores x
cross-sec.
mm
2x1
3G1
3x1
4G1
4x1
5G1
5x1
7G1
10G1
12G1
18G1
25G1
2x1,5
3G1,5
3x1,5
4G1,5
4x1,5
5G1,5
5x1,5
7G1,5
10G1,5
12G1,5
18G1,5
25G1,5
2x2,5
3G2,5
3x2,5
4G2,5
4x2,5
5G2,5
5x2,5
7G2,5
10G2,5
12G2,5
18G2,5
25G2,5

Outer
Cop.
approx. mm weight
kg/km
7,0
19,2
7,4
29,0
7,4
29,0
8,2
38,4
8,2
38,4
9,2
48,0
9,2
48,0
9,9
67,0
11,9
96,0
13,1
115,0
15,7
173,0
18,6
240,0
8,2
29,0
8,6
43,0
8,6
43,0
9,6
58,0
9,6
58,0
10,7
72,0
10,7
72,0
11,6
101,0
15,2
144,0
15,5
173,0
18,6
259,0
22,5
360,0
9,6
48,0
10,1
72,0
10,1
72,0
11,2
96,0
11,2
96,0
12,5
120,0
12,5
120,0
13,8
168,0
16,7
288,0
18,3
432,0
22,0
480,0
26,2
600,0

Weight
approx.
kg/km
82,0
99,0
99,0
140,0
140,0
160,0
160,0
217,0
271,0
301,0
417,0
576,0
97,0
119,0
119,0
148,0
148,0
172,0
172,0
243,0
311,0
392,0
529,0
741,0
160,0
177,0
177,0
209,0
209,0
272,0
272,0
340,0
561,0
799,0
940,0
1121,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14
14
14
14
14


Part no.
12783
12784
12785
12786
12787
12788
12789
12790
12791
12792
12793
12794
12795
12796
12797
12798
12799
12800
12801
12802
12803
12804

No.cores x
cross-sec.
mm
3G4
4G4
5G4
3G6
4G6
5G6
3G10
4G10
5G10
3G16
4G16
5G16
3G25
4G25
5G25
3G35
4G35
5G35
4G50
4G70
4G95
4G120

Outer
Cop.
approx. mm weight
kg/km
11,7
115,0
13,0
154,0
14,5
192,0
13,1
173,0
14,5
230,0
16,2
288,0
16,5
288,0
18,2
384,0
20,3
480,0
20,1
461,0
22,3
614,0
25,0
768,0
24,8
720,0
27,4
960,0
30,5
1200,0
27,1
1008,0
30,0
1344,0
33,3
1680,0
35,8
1920,0
40,9
2688,0
46,2
3648,0
51,6
4608,0

Weight
approx.
kg/km
255,0
319,0
423,0
380,0
441,0
657,0
668,0
796,0
972,0
832,0
1122,0
1604,0
1457,0
1611,0
2070,0
1914,0
2424,0
2970,0
3467,0
4491,0
6170,0
7618,0

AWG-No.
12
12
12
10
10
10
8
8
8
6
6
6
4
4
4
2
2
2
1
2/0
3/0
4/0

Dimensions and specifications may be changed without prior notice. (RA03)

A 67
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JB-750 HMH

flexible control cable, coloured core, halogen-free, extremely

fire resistant, oil resistant1), meter marking

Technical data

Cable structure

Properties

Halogen-free flexible control cable, adapted


to DINVDE0281 part14 and DINVDE0281
part13
Temperature range
flexing -15 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage U0/U 450/750 V
Test voltage 3000 V
Minimum bending radius
flexing approx. 12,5x cable
fixed installation approx. 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of halogen-free compound
TI6, to EDINVDE0281 part14
Colour coded to DIN VDE 0293-308
Green-yellow earth core in the outer layer
Cores stranded in layer with optimal
lay-length
Halogen-free sheath compound TM7, to
EDINVDE0281 part14
Outer jacket colour grey (RAL7001)
with meter marking, change-over in 2011
LS0H = Low Smoke Zero Halogen-free.

) For the critical applications we advise for


consultation
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Tests
Flame test to VDE0482-332-3BS4066
part3/ DINEN60332-3/IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
self-extinguishing and flame retardant
according to VDE0482-332-1-2, DIN
EN60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Halogen-free according to VDE0482
part267/ DINEN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
(equivalent DINVDE0472 part816)


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
Please note the cleanroom qualification
when ordering.
screened analogue type:
JB-750 HMH-C, see pageA77

Application
Halogen-free, flame retardant cables are used as measuring and control cable in machine tools, conveyor belts, production lines as well as
in plant installations, in air-conditioning and steel production works. For fixed installation or flexible application, directed without forcing by
casual, not constantly recurring free movements and without tensile stress, for medium mechanical strain. This cable is suitable for the
application in dry, damp and wet environments and also for laying on, in and under plaster as well as in concrete and masonry excluding in
direct laying in shaked or stamped concrete, not suitable for imbedding in solidified or compressed concrete.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
11965
11966
11967
11968
11969
11970
11971
11972
11973
11974
11975

No.cores x
cross-sec.
mm
3G1,5
4G1,5
5G1,5
3G2,5
4G2,5
5G2,5
3G4
4G4
5G4
4G6
5G6

Outer
Cop.
approx. mm weight
kg/km
6,8
43,0
7,4
58,0
8,3
72,0
8,3
72,0
9,2
96,0
10,1
120,0
9,8
115,0
11,0
154,0
12,3
192,0
13,0
230,0
14,5
288,0

Weight
approx.
kg/km
110,0
140,0
181,0
181,0
223,0
269,0
238,0
292,0
357,0
392,0
501,0

AWG-No.
16
16
16
14
14
14
12
12
12
10
10


Part no.
11976
11977
11978
11979
11980
11981
11982
11983
11984
11985
11986
11987

No.cores x
cross-sec.
mm
4G10
5G10
4G16
5G16
4G25
5G25
4G35
5G35
4G50
4G70
4G95
4G120

Outer
Cop.
approx. mm weight
kg/km
16,4
384,0
18,3
480,0
20,0
614,0
22,6
768,0
24,9
960,0
27,7
1200,0
28,4
1344,0
31,7
1680,0
34,2
1920,0
40,3
2688,0
45,8
3648,0
51,4
4608,0

Weight
approx.
kg/km
750,0
916,0
1037,0
1280,0
1504,0
1883,0
2057,0
2575,0
2808,0
3964,0
4951,0
6387,0

AWG-No.
8
8
6
6
4
4
2
2
1
2/0
3/0
4/0

Dimensions and specifications may be changed without prior notice. (RA03)

A 68
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

(H)03 Z1Z1-F

halogen-free, meter marking

Technical data

Cable structure

Properties

flexible halogen-free control cable


according E DINVDE0281 part14 pr HD
21.14 S1
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage
U0/U 300/300 V
Test voltage 2000 V
Breakdown voltage min. 4000 V
Minimum bending radius
approx. 7,5x cable
Radiation resistance
up to 20x106 cJ/kg (up to 20 Mrad)

Bare copper, fine wire conductor, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5, IEC60228 cl.5, HD383
Insulating jacket thermoplastic compound,
TI6 according to DINVDE0281 part14,
appendixA
Core identification according to
DINVDE0293-308
Green-yellow earth core, 3 cores and above
Core stranded with optimal lay-length
Outer sheath, thermoplastic compound,
TM7 according DINVDE0281 part14,
appendixB
Jacket colour by request
with meter marking, change-over in 2011

Tests
Tested for flame retardation to VDE
0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Smoke density to VDE0482 part268-2
Halogen-free to HD21.14 appendixC
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Colour code:
0 = RAL 9005, black
1 = RAL 9003, white
2 = RAL 5015, blue
3 = RAL 6018, green
4 = RAL 8003, brown
5 = RAL 1021, yellow
6 = RAL 3000, red
7 = RAL 2003, orange
8 = RAL 4005, violet
9 = RAL 7001/7032, grey
Please add the individual part no. for order
with the identification colour code.
Further colours on request.

Application
These cables may be used when halogen-free, low smoke and corrosive gas properties are required in case of fire. For low mechanical
demands in the house, kitchen and office, for small equipment such as, for example, office machines, radios, table and stranded lamps.
Not suitable for:
Cooking and heating equipment, use in high temperature areas (for example, in lighting equipment), outside use, industrial use or idustrial
electrical tools, cables with a nominal cross-section of 0,75 mm comply with the same recommendations as for cable (H)05Z1Z1-F.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
3233_
3234_
3235_

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5

Outer
Cop.
approx. mm weight
kg/km
5,0
9,6
5,3
14,4
5,8
19,2

Weight
approx.
kg/km
39,0
46,0
56,0

AWG-No.
20
20
20


Part no.
3236_
3237_
3238_

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75

Outer
Cop.
approx. mm weight
kg/km
5,4
14,4
5,7
21,6
6,3
29,0

Weight
approx.
kg/km
47,0
55,0
69,0

AWG-No.
18
18
18

Dimensions and specifications may be changed without prior notice. (RA03)

A 69
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

(H)05 Z1Z1-F

halogen-free, meter marking

Technical data

Cable structure

Properties

flexible halogen-free control cable


according EDINVDE0281 part14
prHD21.14S1
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage
U0/U 300/500 V
Test voltage 2500 V
Breakdown voltage min. 5000 V
Minimum bending radius
approx. 7,5x cable
Radiation resistance
up to 20x106 cJ/kg (up to 20 Mrad)

Bare copper, fine wire conductor, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5, IEC60228 cl.5, HD383
Insulating jacket thermoplastic compound,
TI6 according to DINVDE0281 part14,
appendixA
Core identification according to
DINVDE0293-308
Green-yellow earth core, 3 cores and above
Core stranded with optimal lay-length
Outer sheath, thermoplastic compound,
TM7 according DINVDE0281 part14,
appendixB
Jacket colour by request
with meter marking, change-over in 2011

Tests
Tested for flame retardation to VDE
0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Smoke density to VDE0482 part268-2
Halogen-free to HD21.14 appendixC
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Colour code:
0 = RAL 9005, black
1 = RAL 9003, white
2 = RAL 5015, blue
3 = RAL 6018, green
4 = RAL 8003, brown
5 = RAL 1021, yellow
6 = RAL 3000, red
7 = RAL 2003, orange
8 = RAL 4005, violet
9 = RAL 7001/7032, grey
Please add the individual part no. for order
with the identification colour code.
Further colours on request.

Application
These cables may be used when halogen-free, low smoke and corrosive gas properties are required in case of fire. For moderate mechanical
demands in the house, kitchen and office, for house equipment in damp rooms (for example: washing machines, spin-dryers and refrigerators).
Suitable for cooking and heating equipment, providing the cable is not in contact with hot components or heat radiation.
Not suitable for:
in high temperature areas (for example, in lighting equipment), outside buildings, in industrial or agricultural buildings, connection of
electrical power tools.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
3027_
3028_
3029_
3030_
3031_
3032_
3034_
3035_
3036_
3037_
3038_
3039_
3040_
3041_
3042_

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
2x1
3G1
4G1
5G1
2x1,5
3G1,5
4G1,5
5G1,5
2x2,5
3G2,5
4G2,5

Outer
Cop.
approx. mm weight
kg/km
6,2
14,4
6,6
21,6
7,1
29,0
8,0
36,0
6,6
19,0
6,9
29,0
7,7
38,0
8,4
48,0
7,4
29,0
8,1
43,0
9,1
58,0
10,1
72,0
9,3
48,0
10,1
72,0
11,0
96,0

Weight
approx.
kg/km
58,0
68,0
81,0
102,0
67,0
81,0
101,0
107,0
87,0
109,0
117,0
169,0
138,0
172,0
210,0

AWG-No.
18
18
18
18
17
17
17
17
16
16
16
16
14
14
14


Part no.
3043_
3044_
3045_
3046_
3047_

No.cores x
cross-sec.
mm
5G2,5
2x4
3G4
4G4
5G4

Outer
Cop.
approx. mm weight
kg/km
12,3
120,0
10,6
76,8
11,5
115,2
12,5
153,6
14,1
192,0

Weight
approx.
kg/km
260,0
190,0
242,0
298,0
371,0

AWG-No.
14
12
12
12
12

Dimensions and specifications may be changed without prior notice. (RA03)

A 70
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-500 HMH-C

flexible control cable, halogen-free, extremely fire

resistant, oil resistant1), Cu-screened, EMC-preferred type




Technical data

Cable structure

Properties

Halogen-free core flexible control cable


adapted to DINVDE0281 part14 and
DINVDE0281 part13
Temperature range
flexing -15 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage U0/U 300/500 V
Test voltage 2000 V
Minimum bending radius
flexing approx. 12,5x cable
fixed installation approx. 4x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of halogen-free compound
TI6, to EDINVDE0281 part14
Black cores with white continuous
numbering to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores laid up in layers with optimal
lay-length
Separating layer
Screen braid of tinned copper wires,
coverage approx. 85%
Halogen-free sheath compound TM7, to
EDINVDE0281 part14
Jacket colour grey (RAL7001)
with meter marking, change-over in 2011
LS0H = Low Smoke Zero Halogen-free.

) For the critical applications we advise for


consultation
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Tests
Flame test to VDE0482-332-3, BS4066
part3/ DINEN50266-2/ IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Halogen-free according to VDE0482
part267/ DINEN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
(equivalent DINVDE0472 part816)


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
when ordering.
unscreened analogue type:
JZ-500 HMH, see pageA62

Application
Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation
belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing
applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical
loads. The cable is suitable for use in dry, damp and wet environments for installation above, on, in and beneath plaster as well as in masonry
and concrete walls except for direct embedding in vibrated, compacted or tamped concrete, not suitable for imbedding in solidified or
compressed concrete.
An interference-free transmission of signals and pulse in assured by the high degree of screening.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
11656
11657
11342
11658
11343
11659
11660
11663
11665
11667

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4G0,5
4x0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5

Outer
Cop.
approx. mm weight
kg/km
5,7
35,0
5,9
42,0
5,9
42,0
6,4
47,0
6,4
47,0
6,9
56,0
7,6
69,0
9,7
108,0
11,5
145,0
13,6
240,0

Weight
approx.
kg/km
46,0
56,0
56,0
62,0
62,0
75,0
98,0
158,0
216,0
315,0

AWG-No.
20
20
20
20
20
20
20
20
20
20


Part no.
11678
11679
11344
11680
11345
11681
11346
11682
11347
11685
11687
11689

No.cores x
cross-sec.
mm
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
7G0,75
7x0,75
12G0,75
18G0,75
25G0,75

Outer
Cop.
approx. mm weight
kg/km
6,1
40,0
6,3
52,0
6,3
52,0
6,8
60,0
6,8
60,0
7,4
71,0
7,4
71,0
8,2
91,0
8,2
91,0
10,5
142,0
12,7
212,0
15,0
281,0

Weight
approx.
kg/km
60,0
68,0
68,0
78,0
78,0
95,0
95,0
130,0
130,0
203,0
290,0
413,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18

Continuation

A 71
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-500 HMH-C

flexible control cable, halogen-free, extremely fire

resistant, oil resistant1), Cu-screened, EMC-preferred type

Part no.
11700
11701
11348
11702
11349
11703
11704
11707
11709
11711
11722
11723
11350
11724
11725
11726
11729
11731
11733
11744
11745
11746
11747
11748
11751
11766
11768
11769
11770
11771
11781
11782
11783
11784
11785
11786
11787
11788
11789
11790
11793

No.cores x
cross-sec.
mm
2x1
3G1
3x1
4G1
4x1
5G1
7G1
12G1
18G1
25G1
2x1,5
3G1,5
3x1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
2x4
3G4
4G4
5G4
7G4
2G6
3G6
4G6
5G6
7G6
2x10
3G10
4G10
5G10
7G10
4G16

Outer
Cop.
approx. mm weight
kg/km
6,4
50,0
6,7
60,0
6,7
60,0
7,2
71,0
7,2
71,0
8,0
88,0
8,7
111,0
11,4
184,0
13,5
260,0
16,2
349,0
7,0
63,0
7,4
80,0
7,4
80,0
8,1
97,0
9,0
119,0
9,8
147,0
12,8
267,0
15,5
374,0
18,5
526,0
8,4
96,0
8,8
144,0
9,8
148,0
10,8
181,0
11,9
255,0
15,8
441,0
9,9
120,0
10,4
174,0
11,6
230,0
12,9
273,0
14,2
316,0
11,7
173,0
12,5
240,0
13,8
305,0
15,3
439,0
16,9
505,0
14,5
255,0
15,5
350,0
17,1
535,0
19,1
592,0
21,2
810,0
20,8
740,0

Weight
approx.
kg/km
66,0
80,0
80,0
100,0
100,0
130,0
160,0
260,0
382,0
540,0
88,0
100,0
100,0
125,0
158,0
210,0
340,0
480,0
702,0
132,0
168,0
195,0
222,0
345,0
572,0
184,0
238,0
305,0
388,0
504,0
270,0
328,0
416,0
510,0
670,0
420,0
495,0
785,0
855,0
1308,0
882,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
12
12
12
12
12
10
10
10
10
10
8
8
8
8
8
6

Part no.
11794
11812
11795
11796
11797
11798
11799
11800
11801
11802
11803
11804
11805
11806
11807
11808
11809
11810
11811
11813

No.cores x
cross-sec.
mm
5G16
7G16
3G25
4G25
5G25
3G35
4G35
5G35
3G50
4G50
5G50
3G70
4G70
5G70
3G95
4G95
5G95
3G120
4G120
4G185

Outer
Cop.
approx. mm weight
kg/km
23,4
895,0
25,6
1282,0
23,0
1070,0
25,7
1140,0
28,5
1380,0
26,4
1240,0
29,2
1576,0
32,5
1930,0
31,7
1675,0
35,0
2155,0
39,1
2794,0
37,3
2288,0
41,1
3120,0
46,1
3705,0
42,2
3010,0
46,9
4043,0
51,8
5026,0
47,3
3812,0
52,5
5069,0
65,5
8040,0

Weight
approx.
kg/km
1293,0
2149,0
1432,0
1911,0
2414,0
1914,0
2542,0
3180,0
3080,0
3550,0
4753,0
3840,0
4939,0
6572,0
5651,0
6690,0
8370,0
6342,0
8453,0
10800,0

AWG-No.
6
6
4
4
4
2
2
2
1
1
1
2/0
2/0
2/0
3/0
3/0
3/0
4/0
4/0
350 kcmil

Dimensions and specifications may be changed without prior notice. (RA03)

A 72
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MEGAFLEX 500-C

halogen-free, flame retardant, oil-resistant,

UV-resistant, flexible, screened, EMC-preferred types, meter marking




Technical data

Cable structure

Properties

Halogen-free flexible control cable,


core-structure adapted to DINVDE0281
part14, to UL-Style 20939, UL-Std. 758
Temperature range
flexing -30 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Minimum bending radius
flexing approx. 10x cable
fixed installation approx. 4x cable
Flexible
Alternate bending test according to DIN
VDE 0281-2
Coupling resistance
max. 250 Ohm/km

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of halogen-free special
polymer
Black cores with white continuous
numbering to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layer with optimal
lay-length
Separating foil
Tinned copper braided screening, coverage
approx. 85%
Outer sheath, halogen-free special polymer
Outer jacket colour grey (RAL7001)
with meter marking, change-over in 2011
The materials used in manufacture are
cadmium-free and contain no silicone and
are free from substances harmful to the
wetting properties of lacquers

 LS0H = Low Smoke Zero Halogen-free.

Halogen-free
Highly flame-retardant
Resistant to oils and greases
Resistant to UV and weathering
Flexible, abrasion- and wear-resistant
Ozone-resistant
Recycleable
Tests
Flame test to VDE0482-332-3/ BS4066
part3/
DIN EN60332-3/IEC60332-3 (previously
DINVDE0472 part804 test methodC)
Self-extinguishing and flame retardant
according to DINVDE0482-332-1-2, DIN
EN/IEC60332-1 (previously DINVDE0472
part804 test methodB)
Corrosiveness of combustion gases
according to NFX10-702
Halogen-free according to DINVDE0482
part267/ EN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to DINVDE0482
part1034-1+2, DINEN61034-1+2/
IEC61034-1+2, BS7622 part1+2 (previously
DINVDE0472 part816)
Oil-resistant to DIN 60811-2-1 
Hydrolysis-resistant to DINEN61234-1
Ozone-resistant to DIN EN 60811-2-1 /
DIN VDE 0281-2


Approved to UL/CSA
see section N, page N 56

Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
unscreened analogue type:
MEGAFLEX 500, see pageA64, N54

Application
For fixed installation or flexible application, with free movements without forcing which do not constantly recur and without tensile stress,
for high mechanical strain.An interference-free transmission of signals and pulse in assured by the high degree of screening.
As a measuring and control cable primarily in machinery and plant contruction, in building and air-conditoning systems, in warehousing and
converying systems, in ship-building and for regenerative types of energy such as in the construction of wind power stations.
Especially well-suited for use in public buildings, such as airports and train stations, where personal injuries and subsequent damage must
be prevented in the event of a fire.
EMC = Electromagnetic compatibillity
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
13500
13501
13502
13504
13503
13505
13506
13507

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4x0,5
4G0,5
5G0,5
5x0,5
7G0,5

Outer
Cop.
approx. mm weight
kg/km
5,7
35,0
6,0
42,0
6,0
42,0
6,5
47,0
6,5
47,0
7,0
56,0
7,0
56,0
7,9
69,0

Weight
approx.
kg/km
46,0
56,0
56,0
62,0
62,0
75,0
75,0
98,0

AWG-No.
20
20
20
20
20
20
20
20


Part no.
13508
13509
13510
13511
13512
13514
13515

No.cores x
cross-sec.
mm
8G0,5
10G0,5
12G0,5
16G0,5
18G0,5
20G0,5
25G0,5

Outer
Cop.
approx. mm weight
kg/km
8,5
80,0
9,3
94,0
9,6
108,0
10,7
129,0
11,2
145,0
11,9
172,0
13,4
240,0

Weight
approx.
kg/km
116,0
135,0
158,0
210,0
216,0
240,0
315,0

AWG-No.
20
20
20
20
20
20
20

Continuation

A 73
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MEGAFLEX 500-C

halogen-free, flame retardant, oil-resistant,

UV-resistant, flexible, screened, EMC-preferred types, meter marking

Part no.
13516
13517
13518
13519
13520
13521
13522
13523
13524
13525
13526
13527
13528
13529
13530
13531
13532
13533
13534
13535
13536
13537
13538
13539
13540
13541
13542
13543
13544
13545
13546
13547
13548
13549
13550
13552
13554
13556
13557
13558
13559
13560
13561

No.cores x
cross-sec.
mm
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
7G0,75
7x0,75
8G0,75
10G0,75
12G0,75
16G0,75
18G0,75
20G0,75
25G0,75
2x1
3G1
3x1
4G1
4x1
5G1
7G1
8G1
10G1
12G1
16G1
18G1
20G1
25G1
2x1,5
3G1,5
3x1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5
16G1,5
18G1,5
20G1,5
25G1,5

Outer
Cop.
approx. mm weight
kg/km
6,1
40,0
6,4
52,0
6,4
52,0
6,9
60,0
6,9
60,0
7,4
71,0
7,4
71,0
8,6
91,0
8,6
91,0
9,4
110,0
10,2
137,0
10,4
142,0
11,6
200,0
12,4
212,0
12,9
238,0
14,8
281,0
6,4
50,0
6,7
60,0
6,7
60,0
7,3
71,0
7,3
71,0
7,8
88,0
9,1
111,0
9,9
127,0
10,8
150,0
11,2
184,0
12,3
209,0
13,2
260,0
13,8
317,0
15,8
349,0
6,6
63,0
6,9
80,0
6,9
80,0
7,5
97,0
8,4
119,0
10,0
147,0
10,7
170,0
11,8
193,0
12,1
267,0
13,6
315,0
14,6
374,0
15,3
396,0
17,9
526,0

Weight
approx.
kg/km
60,0
68,0
68,0
78,0
78,0
95,0
95,0
130,0
130,0
145,0
180,0
203,0
275,0
290,0
320,0
413,0
66,0
80,0
80,0
100,0
100,0
130,0
160,0
197,0
232,0
260,0
346,0
382,0
440,0
540,0
88,0
100,0
100,0
125,0
158,0
210,0
244,0
315,0
340,0
424,0
480,0
545,0
702,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16

Part no.
13562
13563
13565
13566
13567
13568
13569
13570
13571
13572
13573
13574
13575
13576
13577
13578
13579
13580
13581
13582
13583
13584
13585
13586
13587
13588
13589
13590
13591
13592
13593
13594
13595
13596
13597

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
8G2,5
10G2,5
12G2,5
2x4
3G4
4G4
5G4
7G4
2x6
3G6
4G6
5G6
7G6
2x10
3G10
4G10
5G10
7G10
2x16
3G16
4G16
5G16
7G16
4G25
4x35
4G50
4G70
4G95
4G120
4G150

Outer
Cop.
approx. mm weight
kg/km
8,3
96,0
9,0
144,0
9,8
148,0
10,9
181,0
12,9
255,0
13,8
285,0
15,8
340,0
15,9
441,0
9,8
120,0
10,6
174,0
11,5
230,0
12,7
273,0
13,9
316,0
11,5
173,0
12,4
240,0
13,8
305,0
15,7
439,0
16,6
505,0
14,9
255,0
15,9
350,0
17,8
535,0
19,6
592,0
21,6
810,0
17,3
422,0
18,5
585,0
20,8
740,0
22,9
895,0
25,0
1282,0
26,2
1140,0
30,4
1576,0
34,6
2155,0
41,3
3120,0
46,2
4043,0
51,0
5069,0
59,0
5792,0

Weight
approx.
kg/km
132,0
168,0
195,0
256,0
345,0
390,0
482,0
572,0
220,0
251,0
305,0
388,0
504,0
270,0
351,0
464,0
546,0
670,0
461,0
574,0
785,0
914,0
1308,0
670,0
911,0
1105,0
1293,0
2149,0
1911,0
2542,0
3550,0
4939,0
6690,0
8453,0
9104,0

AWG-No.
14
14
14
14
14
17
14
14
12
12
12
12
12
10
10
10
10
10
8
8
8
8
8
6
6
6
6
6
4
2
1
2/0
3/0
4/0
300 kcmil

Dimensions and specifications may be changed without prior notice. (RA03)

A 74
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-600 HMH-C

flexible control cable, halogen-free, extremely fire resistant,

oil resistant1), 0,6/1kV, screened, EMC-preferred type, meter marking




Technical data

Cable structure

Properties

Halogen-free, flexible control cable, core


construction adapted to DINVDE0281
Part14 and DINVDE0281 Part13
Temperature range
flexing -15 C to +70 C
fixed -40 C to +70 C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4000 V
Minimum bending radius
for permanent bending
approx. 15x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductor to


DINVDE0295 cl.5, BS6360 cl.5 and/or
IEC60228 cl.5
Halogen-free polymer core insulation, TI6
acc. to EDINVDE0281 Part14
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Inner sheath
Tinned copper braided screening, coverage
approx. 85%
Free-free polymer sheath, TM7 acc. to
EDINVDE0281 Part14
Sheath colour black (RAL 9005)
with meter marking, change-over in 2011
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


) For critical applications recommend you


request a consultation
Tests
Flame test acc. to VDE0482-332-3BS4066
Part3/
DIN ENEN60332-3/IEC60332-3 (as per
DINVDE0472 Part804 Test MethodC)
Self-extinguishing and flame-resistant acc.
to DINVDE0482 Part265-2-1/
EN50265-2-1/ IEC60332-1 (as per
DINVDE0472 Part804 Test MethodB)
Corrosiveness of corrosive gases acc. to
VDE0482, Part267/ DINEN50267-2-2/
IEC607542 (as per DINVDE0472, Part813)
Halogen-free acc. to VDE0482, Part267/
DINEN50267-2-1/ IEC60754-1 (as per
DINVDE0472, Part815)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
(equivalent DINVDE0472 part816)


Note

unscreened analogue type:


JZ-600 HMH, see pageA66

Application
Halogen-free, flame retardant cables are used as measuring and control cable in machine tools, conveyor belts, production lines as well as
in plant installations, in heating and air-conditioning systems and steel production works. For fixed installation or flexible application, directed
without forcing by casual, constantly recurring free movements and without tensile stress, for medium mechanical strain. This cable is
suitable for the application in dry, damp and wet environments and outdoors (fixed installation) and for laying on, in and under plaster as
well as in concrete and masonry excluding in direct laying in vibration, compacted or compressed concrete. The dense screening assures
interference-free transmission of all signals and impulses.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
12850
12851
12852
12853
12854
12855
12856
12857
12858
12859
12860
12861
12862
12863

No.cores x
cross-sec.
mm
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75

Outer
Cop.
approx. mm weight
kg/km
8,8
45,0
9,6
54,0
10,2
66,0
11,1
79,0
14,0
137,0
16,2
156,0
19,1
250,0
9,3
57,0
9,9
63,0
10,8
76,0
11,5
100,0
14,8
175,0
17,1
240,0
20,2
306,0

Weight
approx.
kg/km
150,0
170,0
199,0
235,0
320,0
428,0
503,0
155,0
190,0
228,0
323,0
410,0
560,0
730,0

AWG-No.
20
20
20
20
20
20
20
18
18
18
18
18
18
18


Part no.
12864
12865
12866
12867
12868
12869
12870
12871
12872
12873
12874
12875
12876
12877

No.cores x
cross-sec.
mm
3G1
4G1
5G1
7G1
12G1
18G1
25G1
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5

Outer
Cop.
approx. mm weight
kg/km
9,8
64,0
10,6
76,0
11,4
89,0
12,5
114,0
15,7
186,0
18,4
284,0
21,6
387,0
11,1
82,0
11,8
99,0
13,1
123,0
14,2
148,0
18,1
274,0
21,4
386,0
24,9
531,0

Weight
approx.
kg/km
163,0
200,0
239,0
289,0
464,0
628,0
855,0
187,0
240,0
289,0
383,0
592,0
806,0
1241,0

AWG-No.
17
17
17
17
17
17
17
16
16
16
16
16
16
16

Continuation

A 75
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-600 HMH-C

flexible control cable, halogen-free, extremely fire resistant,

oil resistant1), 0,6/1kV, screened, EMC-preferred type, meter marking

Part no.
12878
12879
12880
12881
12882
12883
12884
12885
12886
12887
12888
12889
12890
12891
12892
12893

No.cores x
cross-sec.
mm
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5
3G4
4G4
5G4
3G6
4G6
5G6
3G10
4G10
5G10

Outer
Cop.
approx. mm weight
kg/km
12,7
148,0
13,8
169,0
15,1
220,0
16,6
284,0
21,3
470,0
25,4
572,0
29,6
740,0
14,4
178,0
15,7
234,0
17,3
284,0
15,9
245,0
17,3
316,0
19,2
442,0
19,7
367,0
21,5
549,0
23,7
604,0

Weight
approx.
kg/km
298,0
345,0
427,0
561,0
857,0
1355,0
1995,0
391,0
527,0
700,0
629,0
731,0
1105,0
1125,0
1345,0
1635,0

AWG-No.
14
14
14
14
14
14
14
12
12
12
10
10
10
8
8
8

Part no.
12894
12895
12896
12897
12898
12899
12900
12901
12902
12903
12904
12905
12906
12907

No.cores x
cross-sec.
mm
4G16
5G16
7G16
3G25
4G25
5G25
3G35
4G35
5G35
4G50
4G70
4G95
4G120
4G150

Outer
Cop.
approx. mm weight
kg/km
26,1
807,0
29,0
940,0
31,8
1345,0
28,7
920,0
31,7
1169,0
35,0
1420,0
31,2
1250,0
34,5
1680,0
38,1
2020,0
40,7
2370,0
46,0
3257,0
51,3
4060,0
56,4
5231,0
64,3
6794,0

Weight
approx.
kg/km
1395,0
1870,0
2720,0
2465,0
2750,0
3490,0
3230,0
4100,0
4950,0
5780,0
7480,0
10220,0
13750,0
15900,0

AWG-No.
6
6
6
4
4
4
2
2
2
1
2/0
3/0
4/0
4/0

Dimensions and specifications may be changed without prior notice. (RA03)

Bundling, binding, fastening


Plastic helix
Cable tie
Hook and loop cable tie
Mounting block

You can nd bundling, binding, fastening in our catalogue Cable Accessories.

A 76
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JB-750 HMH-C

flexible control cable, coloured core, halogen-free,

screened, extremely fire resistant, oil resistant1), EMC-preferred type, meter marking


Technical data

Cable structure

Properties

Halogen-free core flexible control cable,


adapted to EDINVDE0281 part14 and
DINVDE0281 part13
Temperature range
flexing -15 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage U0/U 450/750 V
Test voltage 3000 V
Minimum bending radius
flexing approx. 12,5x cable
fixed installation approx. 4x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of halogen-free compound
TI6, to EDINVDE0281 part14
Colour coded to DINVDE0293-308
Green-yellow earth core in the outer layer
Cores laid up in layers with optimal
lay-length
Separating layer
Screen braid of tinned copper wires,
coverage approx. 85%
Halogen-free sheath compound TM7, to
EDINVDE0281 part14
Jacket colour grey (RAL7001)
with meter marking, change-over in 2011
LS0H = Low Smoke Zero Halogen-free.

) For the critical applications we advise for


consultation
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Tests
Flame test to DINVDE0482-332-3BS4066
part3/ DIN EN60332-3/IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
Self-extinguishing and flame retardant
according to DINVDE0482 part265-2-1/
EN50265-2-1/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Corrosiveness of combustion gases
according to DINVDE0482 part267/
EN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Halogen-free according to DINVDE0482
part267/ EN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
(equivalent DINVDE0472 part816)


Note

G = with green-yellow earth core


Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
when ordering.
unscreened analogue type:
JB-750 HMH, see pageA68

Application
Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation
belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing
applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical
loads. The cable is suitable for use in dry, damp and wet environments for installation above, on, in and beneath plaster as well as in masonry
and concrete walls except for direct embedding in vibrated, compacted or tamped concrete, not suitable for imbedding in solidified or
compressed concrete.
An interference-free transmission of signals and pulse in assured by the high degree of screening.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
11942
11943
11944
11945
11946
11947

No.cores x
cross-sec.
mm
3G1,5
4G1,5
5G1,5
3G2,5
4G2,5
5G2,5

Outer
Cop.
approx. mm weight
kg/km
7,4
80,0
8,1
97,0
9,0
119,0
8,8
144,0
9,8
148,0
10,8
181,0

Weight
approx.
kg/km
125,0
160,0
193,0
198,0
240,0
280,0

AWG-No.
16
16
16
14
14
14


Part no.
11948
11949
11950
11951
11952

No.cores x
cross-sec.
mm
3G4
4G4
5G4
4G6
5G6

Outer
Cop.
approx. mm weight
kg/km
10,4
174,0
11,6
230,0
12,9
273,0
13,8
305,0
15,3
439,0

Weight
approx.
kg/km
251,0
315,0
396,0
430,0
524,0

AWG-No.
12
12
12
10
10

Continuation

A 77
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JB-750 HMH-C

flexible control cable, coloured core, halogen-free,

screened, extremely fire resistant, oil resistant1), EMC-preferred type, meter marking

Part no.
11953
11954
11955
11956
11957
11958

No.cores x
cross-sec.
mm
4G10
5G10
4G16
5G16
4G25
5G25

Outer
Cop.
approx. mm weight
kg/km
17,1
535,0
19,1
592,0
20,8
740,0
23,4
895,0
25,7
1140,0
28,5
1380,0

Weight
approx.
kg/km
804,0
942,0
1190,0
1370,0
1968,0
2514,0

AWG-No.

Part no.
8
8
6
6
4
4

11959
11960
11961
11962
11963
11964

No.cores x
cross-sec.
mm
4G35
5G35
4G50
4G70
4G95
4G120

Outer
Cop.
approx. mm weight
kg/km
29,2
1576,0
32,5
1930,0
34,6
2155,0
41,1
3120,0
46,9
4043,0
52,5
5069,0

Weight
approx.
kg/km
2540,0
3260,0
3668,0
5076,0
6807,0
8612,0

AWG-No.
2
2
1
2/0
3/0
4/0

Dimensions and specifications may be changed without prior notice. (RA03)

Marking
Marking rings
Cable marker
Indian pen

You can nd marking in our catalogue Cable Accessories.

A 78
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

OZ-BL
OZ-BL-CY
OB-BL-PAAR-CY
Photo: iStockphoto.com/Michael Utech

PVC Control Cables for Intrinsically Safe Circuits


Electrical cables for intrinsically safe circuits
(separate power circuit of hazard type-i-) have
to be specially marked with a blue outer sheath
(RAL 5015) according to DIN VDE. HELUKABEL
manufactures these cables according to DIN VDE
0165 and in addition, screened types according
to DIN VDE 0165, part 1, EN 60079-14 and IEC
60079-14 section 12.2.2.6.
As these cables are installed with separate power
circuit, the application of green-yellow protective
conductor is not allowed.

The installation of these cables outside of intrinsically safe circuits is not permitted. The installation
can be done in dry and damp environments, but
not in underground and in open air. The special
PVC outer sheath material is resistant to oil and
petrol as well as being ame resistant.
HELUKABEL can deliver almost all the cables as
per typelists on the following pages, predominantly available in stock. Special cables can be
manufactured in a short time.

A 79
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

OZ-BL outer jacket blue, intrinsic safety, flexible, meter marking




Technical data

Cable structure

Properties

Control cable, special PVC with blue outer


jacket for hazardous areas to hazard type
-i- (=intrinsically safe)
For intrinsically safe installation according
to DINEN60079-14 and IEC60079-14
section12.2.2 (VDE0165 part1)
Temperature range
flexing -15 C1) to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Insulation resistance
min. 20 MOhm x km
Mutual capacitance
core/core approx. 120 nF/km
Inductance approx. 0,68 mH/km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
1) cold bending test, impact resistance test
at low temperatures, elongation test at low
temperatures. Tested according VDE0473
Teil811-1-4, EN60811-1-4

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Core insulation of special PVC Z7225
Black cores with white continuous figure
imprint to DINVDE0293 without earth core
Cores stranded in layers with optimal
lay-length
Special PVC outer sheath TM2, to
DINVDE0281 part1 and HD21.1
Colour blue (RAL5015)
with meter marking, change-over in 2011

Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations.
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

For underground laying use NYY with blue


outer sheath.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Instrumentation cable RE-2Y(St)Yv with blue
outer jacket see catalog part B.

Application
For hazardous areas the cables with special marking (blue) (hazard type-i-) used as flexible control and measuring cables to meet the
requirements for the installation of electrical apparatus. These installations are not earthed and require a separate power circuit. Those cables
are not suitable for underground laying.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
14001
14002
14003
14004
14075
14005
14076
14006
14007
14008
14009
14010
14011
14012
14013
14014
14015
14016
14017
14018

No.cores x
cross-sec.
mm
2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
8x0,75
12x0,75
18x0,75
25x0,75
30x0,75
34x0,75
41x0,75
2x1
3x1
4x1
5x1
7x1
12x1
18x1
25x1

Outer
Cop.
approx. mm weight
kg/km
5,3
14,4
5,6
21,6
6,3
29,0
6,9
36,0
7,5
52,0
8,2
58,0
9,8
88,0
12,2
130,0
14,3
180,0
15,3
215,0
16,7
245,0
18,0
298,0
5,6
19,0
5,9
29,0
6,6
38,0
7,3
48,0
8,1
67,0
10,4
115,0
12,9
173,0
15,4
240,0

Weight
approx.
kg/km
46,0
54,0
66,0
80,0
110,0
130,0
179,0
257,0
365,0
448,0
510,0
607,0
60,0
72,0
86,0
104,0
141,0
230,0
343,0
485,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17


Part no.
14019
14020
14021
14022
14023
14024
14025
14026
14027
14100
14101
14102

No.cores x
cross-sec.
mm
2x1,5
3x1,5
4x1,5
5x1,5
7x1,5
12x1,5
18x1,5
25x1,5
30x1,5
3x2,5
4x2,5
5x2,5

Outer
Cop.
approx. mm weight
kg/km
6,4
29,0
6,8
43,0
7,4
58,0
8,3
72,0
9,2
101,0
12,0
173,0
14,6
259,0
17,4
360,0
18,6
440,0
8,3
72,0
9,2
96,0
10,1
120,0

Weight
approx.
kg/km
70,0
90,0
109,0
131,0
184,0
309,0
440,0
620,0
842,0
148,0
178,0
221,0

AWG-No.
16
16
16
16
16
16
16
16
16
14
14
14

Dimensions and specifications may be changed without prior notice. (RA04)

A 80
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

OZ-BL-CY outer jacket blue, intrinsic safety, flexible, meter marking




Technical data

Cable structure

Properties

Control cable, special PVC with blue outer


jacket for hazardous areas to hazard type
-i- (=intrinsically safe)
For intrinsically safe installation according
to DINEN60079-14 and IEC60079-14
section12.2.2. (VDE0165 part1)
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Insulation resistance
min. 20 MOhm x km
Mutual capacitance
core/core approx. 140 nF/km
core/screen approx. 187 nF/km
Inductance approx. 0,68 mH/km
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Core insulation of special PVCZ7225
Black cores with white continuous figure
imprint to DINVDE0293 without earth core
Cores stranded in layers with optimal
lay-length
Core wrapping of plastic foil
Braiding, tinned copper wire screening,
approx. 85% coverage
Special PVC outer sheath TM2, to
DINVDE0281 part1 and HD21.1
Colour blue (RAL5015)
with meter marking, change-over in 2011

Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations.
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

For underground laying use NYY with blue


outer sheath.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Instrumentation cable RE-2Y(St)Yv with blue
outer jacket see catalog part B.

Application
For hazardous areas the cables with special marking (blue) (hazard type-i-) used as flexible control and measuring cables to meet the
requirements for the installation of electrical apparatus. These installations are not earthed and require a separate power circuit. Those cables
are not suitable for underground laying.
The copper braided screening ensures the transmission of data signals and free from interference.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
14028
14029
14030
14031
14088
14032
14033
14034
14035
14036
14037
14038
14039
14040
14041
14042
14043
14044
14045
14046
14047
14048
14049

No.cores x
cross-sec.
mm
2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
8x0,75
10x0,75
12x0,75
18x0,75
20x0,75
25x0,75
30x0,75
34x0,75
41x0,75
2x1
3x1
4x1
5x1
7x1
12x1
18x1
25x1
34x1

Outer
Cop.
approx. mm weight
kg/km
6,1
40,0
6,3
52,0
6,8
60,0
7,4
71,0
8,2
91,0
9,6
110,0
10,3
137,0
10,5
142,0
12,7
212,0
13,3
238,0
15,0
281,0
15,8
320,0
17,2
345,0
18,6
400,0
6,4
50,0
6,7
60,0
7,2
71,0
8,0
88,0
8,7
111,0
11,4
184,0
13,5
260,0
16,2
349,0
18,5
486,0

Weight
approx.
kg/km
59,0
66,0
77,0
93,0
130,0
145,0
180,0
202,0
292,0
362,0
415,0
486,0
523,0
680,0
65,0
81,0
98,0
127,0
158,0
260,0
380,0
534,0
741,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17


Part no.
14050
14051
14052
14053
14054
14055
14056
14057
14058
14059

No.cores x
cross-sec.
mm
2x1,5
3x1,5
4x1,5
5x1,5
7x1,5
12x1,5
18x1,5
25x1,5
30x1,5
34x1,5

Outer
Cop.
approx. mm weight
kg/km
7,0
63,0
7,5
80,0
8,1
97,0
9,0
119,0
9,8
147,0
12,8
267,0
15,4
374,0
18,4
526,0
19,1
555,0
20,8
629,0

Weight
approx.
kg/km
88,0
100,0
126,0
160,0
208,0
338,0
479,0
705,0
830,0
900,0

AWG-No.
16
16
16
16
16
16
16
16
16
16

Dimensions and specifications may be changed without prior notice. (RA04)

A 81
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

OB-BL-PAAR-CY outer jacket blue, intrinsic safety, EMC-preferred type, meter


marking

Technical data

Cable structure

Properties

Special PVC control cable with blue outer


jacket for hazardous areas to hazard type
-i- for intrinsically safe installation according
to DINEN60079-14 and IEC60079-14
section12.2.2. (VDE0165 part1)
Conductor resistance
at 0,5 mm37,8 Ohm/km
at 0,75 mm25,3 Ohm/km
Temperature range
flexing -5 C to +80 C
fixed installation -30 C to +80 C
Nominal voltage 900 V
(not for power installation)
Test voltage
core/core 2000 V
core/screen 1000 V
Breakdown voltage min. 4000 V
Insulation resistance
min. 20 MOhm x km
Mutual capacitance
core/core approx. 105 nF/km
core/screen approx. 145 nF/km
Inductance
approx. 0,68 mH/km
Characteristic impedance
approx. 80 Ohm
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Special PVC core insulation YI2, to
DINVDE0207 part4
Cores colour coded according to DIN47100
Cores twisted in pairs
Pairs stranded in layers with optimal
lay-length
Foil taped
Tinned copper braided screening, approx.
80% coverage
Special PVC outer sheath YM2, to
DINVDE0207 part5
Colour blue RAL5015
with meter marking, change-over in 2011

Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
Instrumentation cable RE-2Y(St)Yv with blue
outer jacket see catalog part B.

Application
For hazardous areas this flexible control cable has been constructed for closed circuit systems in accordance with VDE 0165 part 1, part
12.2.2.6, which covers the requirements for the special marking (blue) of this type (hazard type -i-).
The paired construction and the copper screening afford a good protection against electrical interference and ensure the transmission of
data signals.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
14077
14078
14079
14080
14081
14082
14083
14084
14085
14086
14087

No.pairs x
cross-sec.
mm
2 x 2 x 0,5
3 x 2 x 0,5
4 x 2 x 0,5
6 x 2 x 0,5
8 x 2 x 0,5
10 x 2 x 0,5
12 x 2 x 0,5
16 x 2 x 0,5
20 x 2 x 0,5
24 x 2 x 0,5
25 x 2 x 0,5

Outer
approx.
mm
7,8
8,2
9,0
10,6
12,3
13,5
14,4
16,3
17,7
19,3
19,7

Cop.
weight
kg/km
47,0
67,0
80,0
108,0
129,0
172,0
235,0
301,0
343,0
394,0
406,0

Weight
approx.
kg/km
89,0
104,0
126,0
171,0
251,0
282,0
261,0
445,0
525,0
590,0
622,0

AWG-No.


Part no.

20
20
20
20
20
20
20
20
20
20
20

14089
14090
14091
14092
14093
14094
14095
14096
14097
14098
14099

No.pairs x
cross-sec.
mm
2 x 2 x 0,75
3 x 2 x 0,75
4 x 2 x 0,75
6 x 2 x 0,75
8 x 2 x 0,75
10 x 2 x 0,75
12 x 2 x 0,75
16 x 2 x 0,75
20 x 2 x 0,75
24 x 2 x 0,75
25 x 2 x 0,75

Outer
approx.
mm
8,4
9,0
9,8
12,1
13,4
15,1
15,8
18,0
19,2
21,3
21,8

Cop.
weight
kg/km
60,0
80,0
110,0
142,0
200,0
238,0
270,0
342,0
369,0
451,0
461,0

Weight
approx.
kg/km
105,0
128,0
156,0
216,0
309,0
355,0
405,0
560,0
671,0
795,0
803,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18

Dimensions and specifications may be changed without prior notice. (RA04)

A 82
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BIOFLEX-500-JZ
BIOFLEX-500-JZ-C
KOMPOFLEX JZ-500
KOMPOFLEX JZ-500-C
Photo: FUCHS DEA SCHMIERSTOFFE GMBH & Co. KG

Bio-Oil and microbial resistant Cables


We have joined forces with large scale farmers
and operators of biofuel plants to develop a
tailor-made product the new BIOFLEX-500.

wires from HELUKABEL. Specially modied polymers are used here for the core insulation and
the jacket materials.

HELUKABEL has accordingly matched and extended the range of products from its plant in
Windsbach. Special control cables and wires have
been developed which are not only friendly on
the environment, abrasion-resistant and can be
recycled, they are also resistant to bio-oils. These
are the special BIOFLEX-500-control cables and

In the laboratory, these special compounds have


been subjected to extreme testing according to
VDMA requirements and VDE specications. The
suitability of these compounds has been assessed
by endurance testing to demonstrate the longterm resistance to bio-oils.

A 83
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BIOFLEX-500-JZ

Bio-fuel resistant, abrasion resistant, recyclable environment

friendly, bio-oil resistant1), meter marking

Technical data

Cable structure

Bio-oil resistant, abrasion resistant special


control cable in adapted to DINVDE0281
Temperature range
flexing -20 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 15x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Special polymer core insulation
Black cores with continuous white figure
imprint to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special outher sheath, polymer compound
Colour dark green
with meter marking, change-over in 2011


Properties

Resistant to
Bio-fuel (diesel and petrol), highly resistant
to biologically decomposable oils, Oxygene,
Ozone, Hydrolysis and Microbes
Low adhesion


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
BIOFLEX-500-JZ-C, see pageA85

Application
HELUKABEL BIOFLEX-500-JZ is an extremely robust control cable with high abrasion and tear resistant properties. Due to its high resistance
to Bio-fuel, Bio-oil and coolant emulsions. It is especially suited for use in the machine, tool making and plant industries as well as in the
steel industry for difficult and problem areas. The high flexibility of this cable type makes it quick and easy to install. Suitable for outdoor
lying.
) For the critical applications we advise for consultation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
25620
25621
25622
25623
25624
25625
25626
25627
25628
25629
25630
25631
25632
25633
25634
25635
25636
25637
25638
25639
25640
25641
25642
25643
25644
25645
25646
25647
25648
25649
25650
25651
25652
25653

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
10G0,5
12G0,5
14G0,5
18G0,5
25G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
10G0,75
12G0,75
14G0,75
18G0,75
25G0,75
41G0,75
42G0,75
2x1
3G1
4G1
5G1
7G1
10G1
12G1
14G1
18G1
25G1
41G1
42G1

Outer
Cop.
approx. mm weight
kg/km
5,4
9,6
5,9
14,4
6,3
19,0
6,9
24,0
7,8
33,6
9,6
48,0
10,0
58,0
10,3
67,0
11,5
86,0
13,6
120,0
5,4
14,4
6,2
21,6
6,7
29,0
7,3
36,0
8,8
50,0
10,5
72,0
11,0
86,0
11,4
101,0
12,6
130,0
15,2
180,0
18,0
296,0
18,5
310,0
6,6
19,0
7,0
29,0
7,6
38,0
8,2
48,0
9,6
67,0
11,6
96,0
12,0
115,0
13,2
134,0
14,5
173,0
17,6
240,0
21,1
394,0
21,5
403,0

Weight
approx.
kg/km
45,0
55,0
65,0
75,0
90,0
120,0
135,0
170,0
205,0
270,0
44,0
53,0
64,0
76,0
96,0
140,0
170,0
202,0
260,0
282,0
600,0
620,0
53,0
63,0
75,0
89,0
115,0
166,0
201,0
230,0
289,0
380,0
720,0
740,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
17


Part no.
25654
25655
25656
25657
25658
25659
25660
25661
25662
25663
25664
25665
25666
25667
25668
25669
25670
25671
25672
25673
25674
25675
25676
25677
25678
25679
25680
25681
25682
25683
25684
25685
25686
25687
25688
25689
25690

No.cores x
cross-sec.
mm
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
10G1,5
12G1,5
14G1,5
18G1,5
25G1,5
42G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5
2x4
3G4
4G4
5G4
3G6
4G6
5G6
3G10
4G10
5G10
4G16
5G16
4G25
4G35
4G50
4G70
4G95
4G120

Outer
Cop.
approx. mm weight
kg/km
7,2
29,0
7,6
43,0
8,2
58,0
9,0
72,0
10,7
101,0
13,0
144,0
13,4
173,0
14,5
202,0
16,0
259,0
19,5
360,0
23,8
605,0
8,6
48,0
9,3
72,0
10,3
96,0
11,5
120,0
13,4
168,0
17,0
288,0
20,0
432,0
24,1
600,0
10,4
77,0
11,2
115,0
12,5
154,0
13,8
192,0
13,0
173,0
14,7
230,0
16,0
288,0
16,7
288,0
18,3
384,0
20,5
480,0
21,1
614,0
23,6
768,0
29,4
960,0
32,8
1344,0
38,9
1920,0
44,7
2688,0
59,6
3648,0
64,5
4608,0

Weight
approx.
kg/km
68,0
87,0
106,0
131,0
173,0
245,0
293,0
347,0
454,0
641,0
1100,0
110,0
146,0
183,0
222,0
293,0
512,0
740,0
940,0
147,0
228,0
291,0
355,0
362,0
468,0
570,0
555,0
720,0
894,0
1063,0
1400,0
1590,0
2200,0
2400,0
4400,0
6000,0
7400,0

AWG-No.
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14
12
12
12
12
10
10
10
8
8
8
6
6
4
2
1
2/0
3/0
4/0

Dimensions and specifications may be changed without prior notice. (RA05)

A 84
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BIOFLEX-500-JZ-C

Bio-fuel resistant, abrasion resistant, recyclable

environmentfriendly, bio-oil resistant1), Cu-screened, EMC-preferred type, meter marking




Technical data

Cable structure

Bio-oil resistant, abrasion resistant special


control cable in adapted to DINVDE0281
Temperature range
flexing -20 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 20x cable
fixed installation 6x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Special polymer core insulation
Black cores with continuous white figure
imprint to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special inner sheath
Screen of Cu braid, tinned coverage
approx. 85%
Fleece separator, ensure good dismantling
ability
Special outher sheath, polymer compound
Colour dark green
with meter marking, change-over in 2011

Properties

Resistant to
Bio-fuel (diesel and petrol), highly resistant
to biologically decomposable oils, Oxygene,
Ozone, Hydrolysis and Microbes
Low adhesion


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
BIOFLEX-500-JZ, see pageA84

Application
HELUKABEL BIOFLEX-500-JZ-C is an extremely robust control cable with high abrasion and tear resistant properties. Due to its high resistance
to Bio-fuel, Bio-oil and coolant emulsions. It is especially suited for use in the machine, tool making and plant industries as well as in the
steel industry for difficult and problem areas. The inner sheaths of those cables raise the mecanical stress. The high flexibility of this cable
type makes it quick and easy to install. Suitable for outdoor lying. These screened cables are particularly suitable for the interference-free
transmission in instrumentation and control engineering applications (electromagnetic compatibility). ) For the critical applications we advise
for consultation.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
25691
25692
25693
25694
25695
25696
25697
25698
25699
25700
25701
25702
25703
25704
25705
25706
25707
25708
25709
25710
25711
25712

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
10G0,5
12G0,5
14G0,5
18G0,5
25G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
10G0,75
12G0,75
14G0,75
18G0,75
25G0,75
41G0,75
42G0,75

Outer
Cop.
approx. mm weight
kg/km
6,6
41,0
7,1
45,0
7,6
54,0
8,2
66,0
9,4
79,0
11,2
107,0
11,3
137,0
11,9
142,0
12,9
156,0
15,9
250,0
7,2
46,0
7,7
57,0
8,2
63,0
8,8
76,0
10,1
100,0
12,2
140,0
12,3
175,0
13,0
190,0
14,6
240,0
17,8
306,0
21,5
403,0
22,0
410,0

Weight
approx.
kg/km
68,0
84,0
95,0
107,0
135,0
170,0
195,0
222,0
278,0
406,0
88,0
98,0
112,0
130,0
185,0
270,0
294,0
317,0
357,0
510,0
951,0
975,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
18


Part no.
25713
25714
25715
25716
25717
25718
25719
25720
25721
25722
25723
25724
25725
25726
25727
25728
25729
25730
25731
25732
25733
25734

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
10G1
12G1
14G1
18G1
25G1
41G1
42G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
10G1,5
12G1,5
14G1,5
18G1,5
25G1,5

Outer
Cop.
approx. mm weight
kg/km
8,1
54,0
8,5
64,0
9,0
76,0
9,9
89,0
11,6
114,0
14,0
156,0
14,4
186,0
15,0
198,0
17,0
284,0
20,6
387,0
25,0
578,0
25,5
590,0
8,5
64,0
8,9
82,0
9,7
99,0
10,8
123,0
12,5
148,0
15,1
198,0
15,5
274,0
16,1
294,0
18,6
386,0
22,1
531,0

Weight
approx.
kg/km
98,0
102,0
145,0
170,0
220,0
330,0
350,0
402,0
515,0
690,0
1070,0
1096,0
130,0
152,0
167,0
203,0
305,0
422,0
435,0
480,0
642,0
803,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16

Continuation

A 85
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BIOFLEX-500-JZ-C

Bio-fuel resistant, abrasion resistant, recyclable

environmentfriendly, bio-oil resistant1), Cu-screened, EMC-preferred type, meter marking

Part no.
25735
25736
25737
25738
25739
25740
25741
25742
25743
25744
25745
25746
25747

No.cores x
cross-sec.
mm
41G1,5
42G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
2x4
3G4
4G4
5G4
3G6

Outer
Cop.
approx. mm weight
kg/km
27,2
840,0
27,5
890,0
10,6
110,0
11,1
148,0
12,1
169,0
13,2
220,0
15,9
284,0
19,5
470,0
12,6
124,0
13,4
178,0
15,0
234,0
16,4
284,0
15,2
245,0

Weight
approx.
kg/km
1360,0
1375,0
180,0
215,0
268,0
349,0
406,0
720,0
300,0
340,0
408,0
504,0
453,0

AWG-No.
16
16
14
14
14
14
14
14
12
12
12
12
10

Part no.
25748
25749
25750
25751
25752
25753
25754
25755
25756
25757
25758
25759
25760

No.cores x
cross-sec.
mm
4G6
5G6
3G10
4G10
5G10
4G16
5G16
4G25
4G35
4G50
4G70
4G95
4G120

Outer
Cop.
approx. mm weight
kg/km
17,0
316,0
18,6
442,0
19,5
367,0
21,5
549,0
23,9
604,0
24,6
807,0
27,3
940,0
30,6
1169,0
36,9
1680,0
41,3
2370,0
48,8
3257,0
61,8
4060,0
65,7
5231,0

Weight
approx.
kg/km
560,0
700,0
750,0
1023,0
1114,0
1385,0
1550,0
1894,0
2395,0
3312,0
4605,0
6055,0
7318,0

AWG-No.
10
10
8
8
8
6
6
4
2
1
2/0
3/0
4/0

Dimensions and specifications may be changed without prior notice. (RA05)

Tools
Cable shears
Box spanners
Strippers
Crimping tools
Pliers
Skinning knife

You can nd tools in our catalogue Cable Accessories.

A 86
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

KOMPOFLEX JZ-500

halogen-free, microbes resistant, low adhesion,

meter marking


Technical data

Cable structure

Microbes resistant, halogen-free special


control cable in adapted to DINVDE0281
part13 
Temperature range
flexing -30 C to + 90 C
fixed installation -40 C to +100 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Tinned copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Special thermoplastic polymer-core
insulation
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Outher sheath, special thermoplastic
polymer
Colour black (RAL9005)
with meter marking, change-over in 2011


Properties

Resistant to
UV-radiation, Oxygene, Ozone, Microbes,
Hydrofluoric acid, Hydrochloric acid and
diluted sulfuric acid
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Low adhesion


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
KOMPOFLEX JZ-500-C, see pageA88

Application
Extremly robust universal cable. This cable is specially installed in rubbish, sewage-treatment plants, composting works, animal stalls
and greenhouses. Suitable for installation for flexible use for medium mechanical, stresses with free movement without tensile stress or
forced movements in dry, moist and wet rooms as well as outside.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
26125
26126
26127
26128
26129
26130
26131
26132
26133
26135
26136
26137
26138
26139
26140
26141
26142
26143
26144
26145
26146
26147
26149
26150
26151
26152
26153
26154
26155
26156
26157
26158
26159
26160
26162
26163
26164
26165
26166
26167

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
20G0,5
25G0,5
34G0,5
42G0,5
50G0,5
61G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
20G0,75
25G0,75
34G0,75
42G0,75
50G0,75
61G0,75
2x1
3G1
4G1
5G1
7G1
12G1
18G1
20G1
30G1
34G1
42G1
50G1
61G1
2x1,5

Outer
Cop.
approx. mm weight
kg/km
4,8
9,6
5,1
14,4
5,7
19,0
6,2
24,0
7,4
33,6
9,1
58,0
10,7
86,0
11,2
96,0
13,0
120,0
14,5
163,0
15,8
202,0
17,3
240,0
19,4
293,0
5,2
14,4
5,5
21,6
6,2
29,0
6,8
36,0
8,1
50,0
9,9
86,0
11,9
130,0
12,6
144,0
14,5
180,0
16,4
245,0
17,6
302,0
19,8
360,0
20,9
439,0
5,5
19,0
6,0
29,0
6,6
38,0
7,2
48,0
8,6
67,0
10,7
115,0
12,7
173,0
13,5
192,0
16,0
288,0
17,4
326,0
18,9
403,0
21,0
480,0
22,2
586,0
6,3
29,0

Weight
approx.
kg/km
41,0
50,0
61,0
72,0
86,0
130,0
198,0
211,0
260,0
361,0
405,0
541,0
670,0
42,0
49,0
60,0
71,0
88,0
161,0
250,0
266,0
273,0
501,0
591,0
712,0
820,0
48,0
56,0
70,0
81,0
109,0
191,0
274,0
314,0
492,0
640,0
804,0
932,0
1102,0
60,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
17
17
16


Part no.
26168
26169
26170
26171
26172
26173
26174
26175
26176
26177
26178
26179
26180
26181
26182
26183
26184
26185
26186
26187
26189
26190
26191
26192
26193
26195
26196
26197
26198
26199
26200
26201
26202
26204
26206
26208
26212
26215
26216

No.cores x
cross-sec.
mm
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
20G1,5
25G1,5
34G1,5
42G1,5
50G1,5
61G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5
3G4
4G4
5G4
7G4
12G4
3G6
4G6
5G6
7G6
3G10
4G10
5G10
7G10
4G16
7G16
4G25
4G35
4G50
5G50

Outer
Cop.
approx. mm weight
kg/km
6,7
43,0
7,3
58,0
8,2
72,0
9,8
101,0
12,1
173,0
14,5
259,0
15,2
288,0
17,8
360,0
19,8
490,0
21,4
605,0
23,7
720,0
25,3
878,0
7,6
48,0
8,3
72,0
9,1
96,0
10,2
120,0
12,1
168,0
15,2
288,0
18,1
432,0
22,2
600,0
9,9
115,0
11,0
154,0
12,1
192,0
13,3
269,0
18,3
461,0
11,7
173,0
13,0
230,0
14,5
288,0
16,0
403,0
15,0
288,0
16,8
384,0
18,7
480,0
20,6
672,0
19,7
614,0
24,4
1075,0
25,2
960,0
29,0
1344,0
33,4
1920,0
37,2
2400,0

Weight
approx.
kg/km
79,0
98,0
112,0
159,0
280,0
420,0
480,0
604,0
812,0
1002,0
1240,0
1421,0
99,0
136,0
170,0
204,0
281,0
487,0
704,0
909,0
224,0
289,0
357,0
451,0
782,0
345,0
417,0
521,0
622,0
537,0
699,0
851,0
1102,0
1028,0
1772,0
1577,0
2097,0
2914,0
3919,0

AWG-No.
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14
12
12
12
12
12
10
10
10
10
8
8
8
8
6
6
4
2
1
1

Dimensions and specifications may be changed without prior notice. (RA05)

A 87
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

KOMPOFLEX JZ-500-C

halogen-free, microbes resistant, Cu-screened,

EMC-preferred type, meter marking

Technical data

Cable structure

Screened microbes resistant, halogen-free


special control cable in adapted to
DINVDE0281 part13 
Temperature range
flexing -30 C to + 90 C
fixed installation -40 C to +100 C
Nominal voltage U0/U 300/500 V
Test voltage
core/core 4000 V
core/screen 2000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Tinned copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Special thermoplastic polymer core
insulation
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Inner-sheath to special thermoplastic
polymer
Screen of tinned cu braid, coverage approx.
85%
Outer sheath, special thermoplastic
polymer
Colour black (RAL9005)
with meter marking, change-over in 2011


Properties

Resistant to
UV-radiation, Oxygene, Ozone, Microbes,
Hydrofluoric acid, Hydrochloric acid and
diluted sulfuric acid
Low adhesion
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
KOMPOFLEX JZ-500, see pageA87

Application

Extremly robust universal cable.


This cable is specially installed in rubbish, sewage-treatment plants, composting works, animal stalls and greenhouses. The inner sheaths of
those cables raise the mechanical stress. Suitable for installation for flexible use for medium mechanical, stresses with free movement
without tensile stress or forced movements in dry, moist and wet rooms as well as outside. The high flexibility of this cable type makes it
quick and easy to install.
This screened cable is ideal for use in data signal transmission free from interferences for measurement and control engineering technology.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
26217
26218
26219
26220
26221
26222
26223
26224
26225
26226
26227
26228
26229
26230
26231
26232
26233
26234
26235
26236
26237
26238
26239
26240
26241
26242
26243
26244

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
20G0,5
25G0,5
30G0,5
34G0,5
42G0,5
50G0,5
61G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
20G0,75
25G0,75
30G0,75
34G0,75
42G0,75
50G0,75
61G0,75

Outer
Cop.
approx. mm weight
kg/km
6,9
41,0
7,2
45,0
7,8
54,0
8,3
66,0
9,5
79,0
11,3
137,0
13,1
156,0
13,8
173,0
15,7
250,0
16,0
297,0
17,4
316,0
18,9
360,0
20,9
407,0
22,9
520,0
7,6
46,0
7,8
57,0
8,3
63,0
9,1
76,0
10,4
100,0
12,5
175,0
14,3
240,0
15,2
262,0
17,6
306,0
18,1
340,0
19,5
346,0
20,9
410,0
23,2
470,0
25,0
550,0

Weight
approx.
kg/km
68,0
84,0
95,0
107,0
135,0
195,0
278,0
310,0
406,0
520,0
571,0
651,0
760,0
911,0
88,0
98,0
112,0
130,0
185,0
294,0
357,0
404,0
510,0
561,0
670,0
960,0
1104,0
1270,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
18
18
18


Part no.
26245
26246
26247
26248
26249
26250
26251
26252
26253
26254
26255
26256
26257
26258
26259
26260
26261
26262
26263
26264
26265
26266
26267
26268
26269
26270
26271
26272

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
12G1
18G1
20G1
25G1
30G1
34G1
42G1
50G1
61G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
20G1,5
25G1,5
30G1,5
34G1,5
42G1,5
50G1,5
61G1,5

Outer
Cop.
approx. mm weight
kg/km
7,9
54,0
8,2
64,0
8,9
76,0
9,5
89,0
11,0
114,0
13,1
186,0
15,4
284,0
16,0
325,0
18,3
387,0
18,8
457,0
20,3
500,0
21,8
590,0
24,0
681,0
26,2
710,0
8,4
64,0
9,0
82,0
9,6
99,0
10,5
123,0
12,1
148,0
14,9
274,0
17,1
386,0
18,0
401,0
20,7
531,0
21,1
598,0
22,7
671,0
24,4
890,0
26,8
997,0
29,6
1120,0

Weight
approx.
kg/km
98,0
102,0
145,0
171,0
210,0
330,0
488,0
545,0
690,0
770,0
811,0
996,0
1320,0
1480,0
130,0
154,0
165,0
197,0
305,0
435,0
642,0
718,0
803,0
961,0
1060,0
1300,0
1677,0
1971,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16

Continuation

A 88
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

KOMPOFLEX JZ-500-C

halogen-free, microbes resistant, Cu-screened,

EMC-preferred type, meter marking

Part no.
26273
26274
26275
26276
26277
26278
26279
26280
26281
26282
26283
26284
26285
26286
26287
26288
26289
26290
26291

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5
2x4
3G4
4G4
5G4
7G4
12G4
2x6
3G6
4G6
5G6
7G6

Outer
Cop.
approx. mm weight
kg/km
10,0
110,0
10,7
148,0
11,4
169,0
12,5
220,0
15,0
284,0
18,0
470,0
21,2
572,0
25,5
740,0
11,6
124,0
12,3
178,0
13,4
234,0
14,8
284,0
16,2
321,0
21,8
581,0
13,5
176,0
14,2
245,0
15,6
316,0
17,0
442,0
18,7
530,0

Weight
approx.
kg/km
180,0
215,0
268,0
349,0
404,0
710,0
891,0
1104,0
300,0
340,0
408,0
504,0
640,0
894,0
391,0
453,0
560,0
680,0
891,0

AWG-No.
14
14
14
14
14
14
14
14
12
12
12
12
12
12
10
10
10
10
10


Part no.
26292
26293
26294
26295
26296
26297
26298
26299
26300
26301
26302
26303
26304
26305
26306

No.cores x
cross-sec.
mm
3G10
4G10
5G10
7G10
3G16
4G16
5G16
7G16
3G25
4G25
5G25
4G35
5G35
4G50
5G50

Outer
Cop.
approx. mm weight
kg/km
17,8
367,0
19,7
549,0
21,6
604,0
24,0
820,0
20,7
653,0
22,6
807,0
25,2
940,0
27,6
1345,0
26,0
920,0
28,9
1169,0
31,8
1420,0
33,4
1680,0
37,2
2020,0
38,2
2370,0
43,0
2880,0

Weight
approx.
kg/km
730,0
1004,0
1170,0
1405,0
894,0
1311,0
1550,0
1820,0
1430,0
1894,0
2272,0
2310,0
2740,0
3270,0
4080,0

AWG-No.
8
8
8
8
6
6
6
6
4
4
4
2
2
1
1

Dimensions and specifications may be changed without prior notice. (RA05)

Signal and power circular connectors


Series A, B, C, D, F and S
Tools
Accessories
Online congurator
Pre-assembled cables

You can nd signal and power circular connectors in our catalogue Cable Accessories.

A 89
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NANOFLEX HC 500
NANOFLEX HC 500-C
NANOFLEX HC TRONIC
NANOFLEX HC TRONIC-C
Photos: fotolia.com

Hygienic Cable
In the food and beverage processing industry
that is one of the most highly regulated
industries, hygiene is crucial. To achieve
complete hygiene security and to produce highquality products all operational parameters have
to be monitored continuously. For these special
environments we are now able to offer cables
with an antimicrobial outer sheath. The specially
formulated insulation material helps to
prevent contamination from impurities and
the growth of micro-organisms on the outer

sheaths. The cable is resistant to all standard


detergents and offers good cleaning properties.
A FCN (Food Contact Notication) has been
issued for the antimicrobial material used.
A test certicate issued by the federal agency
of material testing which approves the
antimicrobial properties is available.

A 90
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NANOFLEX HC*500 cut-resistant, meter marking




Technical data

Cable structure

Properties

Special polyurethane sheathed cable


according to DIN VDE 0245, 0281
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage
min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper conductor, fine wire stranded


according to DIN VDE 0295 cl. 5, BS 6360
cl. 5 or IEC 60228 cl. 5
Special PVC core insulation TI2 according
to DIN VDE 0281 Part 1
Black cores with sequential white
numbering in accordance with DIN VDE
0293
Green-yellow earth core in the outer layer,
3 cores and more
Cores stranded in layers with optimal
lay-lengths
Outer sheath from special
fullpolyurethane TMPU according to
DIN EN 50363-10-2
Sheath colour - light grey (RAL 7035)
With meter marking

Resistant to UV radiation, oxygen, ozone,


hydrolysis, microbes
Self-extinguishing and flame retardant in
accordance to VDE 0482-332-1-2, DIN EN
60332-1/ IEC 60332-1 (conforms to DIN VDE
0472 Part 804 Test method B)
The materials used in manufacture are free
of silicone, cadmium and substances that
impair paint wetting
Good cleaning properties
Resistent to all standard detergents


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
screened analogue type:
NANOFLEXHC 500-C, see pageA92
*Hygienic Cable

Application
Special PUR cable for the food and beverage industry; outer sheath with antimicrobial properties increases process reliability in all applications
in which food and beverages are processed unpacked and unsealed, e.g. processing of dairy products, meat, fish; production of convenience
foods, brewery andbeverage industry
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
27031
27032
27033
27034
27035
27036
27037
27038
27039
27040
27041
27042
27043
27044
27045
27046
27047
27048
27049
27050
27051
27052
27053
27054
27055
27056
27057
27058
27059
27060

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4G0,5
4x0,5
5G0,5
5x0,5
7G0,5
7x0,5
10G0,5
12G0,5
18G0,5
25G0,5
2G0,75
3G0,75
3G0,75
4G0,75
4x0,75
5G0,75
5x0,75
7G0,75
7x0,75
10G0,75
12G0,75
18G0,75
25G0,75
2x1
3G1
3G1
4G1

Outer
Cop.
approx. mm weight
kg/km
4,8
10,0
5,1
14,0
5,1
14,0
5,7
19,0
5,7
19,0
6,2
24,0
6,2
24,0
7,2
34,0
7,2
34,0
8,8
48,0
9,1
58,0
10,7
86,0
13,2
120,0
5,4
14,0
5,7
22,0
5,7
22,0
6,2
29,0
6,2
29,0
6,8
36,0
6,8
36,0
8,1
50,0
8,1
50,0
9,6
72,0
9,6
86,0
11,9
130,0
14,5
180,0
5,7
19,0
6,0
29,0
6,0
29,0
6,6
38,0

Weight
approx.
kg/km
45,0
55,0
55,0
65,0
65,0
75,0
75,0
90,0
90,0
120,0
135,0
205,0
270,0
44,0
53,0
53,0
64,0
64,0
76,0
76,0
96,0
96,0
140,0
170,0
260,0
282,0
53,0
63,0
63,0
75,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17


Part no.
27061
27062
27063
27064
27065
27066
27067
27068
27069
27070
27071
27072
27073
27074
27075
27076
27077
27078
27079
27080
27081
27082
27083
27084
27085
27086
27087
27088
27089

No.cores x
cross-sec.
mm
4x1
5G1
5x1
7G1
7x1
10G1
12G1
18G1
25G1
2x1,5
3G1,5
3x1,5
4G1,5
4x1,5
5G1,5
5x1,5
7G1,5
7x1,5
12G1,5
18G1,5
25G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
4G4
5G4

Outer
Cop.
approx. mm weight
kg/km
6,6
38,0
7,1
48,0
7,1
48,0
8,6
67,0
8,6
67,0
10,2
96,0
10,7
115,0
12,9
173,0
14,9
240,0
6,2
29,0
6,6
43,0
6,6
43,0
7,2
58,0
7,2
58,0
8,2
72,0
8,2
72,0
9,8
101,0
9,8
101,0
12,0
173,0
14,5
259,0
17,8
360,0
7,8
48,0
8,3
72,0
9,2
96,0
10,1
120,0
12,3
168,0
15,3
288,0
11,0
154,0
12,7
192,0

Weight
approx.
kg/km
75,0
89,0
89,0
115,0
115,0
166,0
201,0
289,0
380,0
68,0
87,0
87,0
106,0
106,0
131,0
131,0
173,0
173,0
293,0
454,0
641,0
110,0
146,0
183,0
222,0
293,0
512,0
291,0
355,0

AWG-No.
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
12
12

Dimensions and specifications may be changed without prior notice. (RA02)

A 91
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NANOFLEX HC*500-C EMC preferred type, cut-resistant, screened, no inner


sheath, meter marking

Technical data

Cable structure

Properties

Special polyurethane sheathed cable


accordingto DIN VDE 0245 part 201 to 1,5
mm,
according to DIN VDE 0245 part 102 from
2,5 mm
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Breakdown voltage
min. 6000 V
Insulation resistance
Min. 20 MOhm x km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper conductor, fine wire stranded


according to DIN VDE 0295 cl. 5, BS 6360
cl. 5 or IEC 60228 cl. 5
Special PVC core insulation TI2 according
to DIN VDE 0281 Part 1
Black cores with sequential white
numbering in accordance with DIN VDE
0293
Green-yellow earth core in the outer layer,
3 cores and more
Cores stranded in layers with optimal
lay-lengths
Separating foil
Braided screening of tinned copper wires,
coverage approx. 85%
Outer sheath from special
fullpolyurethane TMPU according to
DIN EN 50363-10-2
Sheath colour - light grey (RAL 7035)
With meter marking

Resistant to UV radiation, oxygen, ozone,


hydrolysis, microbes
Self-extinguishing and flame retardant in
accordance to VDE 0482-332-1-2, DIN EN
60332-1/ IEC 60332-1 (conforms to DIN VDE
0472 Part 804 Test method B)
The materials used in manufacture are free
of silicone, cadmium and substances that
impair paint wetting
Good cleaning properties
Resistent to all standard detergents


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ)
Unscreened analogue type:
NANOFLEX HC 500, see pageA91
*Hygienic Cable

Application
Screened special PUR cable for the food and beverage industry; outer sheath with antimicrobial properties increases process reliability in all
applications in which food and beverages are processed unpacked and unsealed, e.g. processing of dairy products, meat, fish; production
of convenience foods, brewery and beverage industry
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
27105
27106
27107
27108
27109
27110
27111
27112
27113
27114
27115
27116
27117
27118
27119
27120
27121
27122
27123
27124
27125
27126
27127
27128
27129
27130
27131
27132
27133
27134

No.cores x
cross-sec.
mm
2x0,5
3x0,5
3x0,5
4G0,5
4x0,5
5x0,5
5G0,5
7G0,5
7x0,5
10G0,5
12G0,5
18G0,5
25G0,5
2x0,75
3x0,75
3G0,75
4G0,75
4x0,75
5x0,75
5G0,75
7G0,75
7x0,75
10G0,75
12G0,75
18G0,75
25G0,75
2x1
3G1
3x1
4x1

Outer
Cop.
approx. mm weight
kg/km
5,3
35,0
5,6
42,0
5,6
42,0
6,2
47,0
6,2
47,0
6,5
56,0
6,5
56,0
7,5
69,0
7,5
69,0
9,0
94,0
9,2
108,0
10,9
145,0
13,3
240,0
5,8
40,0
6,1
52,0
6,1
52,0
6,5
60,0
6,5
60,0
7,1
71,0
7,1
71,0
8,3
91,0
8,3
91,0
10,1
137,0
10,3
142,0
12,1
212,0
14,9
281,0
6,1
50,0
6,3
60,0
6,3
60,0
6,9
71,0

Weight
approx.
kg/km
47,0
57,0
57,0
60,0
60,0
75,0
75,0
97,0
97,0
133,0
158,0
218,0
315,0
60,0
67,0
67,0
76,0
76,0
92,0
92,0
131,0
131,0
180,0
204,0
290,0
413,0
66,0
82,0
82,0
100,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17


Part no.
27135
27136
27137
27138
27139
27140
27141
27142
27143
27144
27145
27146
27147
27148
27149
27150
27151
27152
27153
27154
27155
27156
27157
27158
27159
27160
27161
27162
27163

No.cores x
cross-sec.
mm
4G1
5x1
5G1
7x1
7G1
10G1
12G1
18G1
25G1
2x1,5
3x1,5
3G1,5
4x1,5
4G1,5
5x1,5
5G1,5
7x1,5
7G1,5
12G1,5
18G1,5
25G1,5
2x2,5
3x2,5
4G2,5
5G2,5
7G2,5
12G2,5
4G4
5G4

Outer
Cop.
approx. mm weight
kg/km
6,9
71,0
7,5
88,0
7,5
88,0
8,9
111,0
8,9
111,0
10,7
150,0
10,9
184,0
13,0
260,0
15,9
349,0
6,6
63,0
6,9
80,0
6,9
80,0
7,5
97,0
7,5
97,0
8,4
119,0
8,4
119,0
10,0
147,0
10,0
147,0
12,1
267,0
14,6
374,0
17,9
526,0
8,2
96,0
8,6
144,0
9,6
148,0
10,6
181,0
12,6
255,0
15,5
441,0
11,0
230,0
12,3
273,0

Weight
approx.
kg/km
100,0
128,0
128,0
157,0
157,0
230,0
262,0
381,0
535,0
87,0
102,0
102,0
127,0
127,0
159,0
159,0
207,0
207,0
340,0
480,0
704,0
131,0
168,0
194,0
222,0
345,0
570,0
310,0
386,0

AWG-No.
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
12
12

Dimensions and specifications may be changed without prior notice. (RA02)

A 92
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NANOFLEX HC*TRONIC flexible, colour code to DIN 47100, meter marking




Technical data

Cable structure

Properties

Special polyurethane data cable according


to DIN VDE 0245, 0812
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Peak operating voltage
(not for purposes of high current and
power installation)
0,14 mm = 350 V
>=0,25 mm = 500 V
Test voltage
to0,25 mm 1200 V
from 0,34 mm 2000 V
Breakdown voltage
to 0,25 mm 2400 V
from 0,34 mm 4000 V
Insulation resistance
min. 20 MOhm x km
Operating capacity
(approx. value) at 800 Hz
0,14 mm 120 pF/m
>=0,25 mm 150 pF/m
Inductance approx. 0,65 mH/km
Impedance approx. 78 Ohm
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to100 Mrad)

Bare copper, fine wire conductor,fine


wirestranded accordingto DIN VDE 0295
cl.5or 0245 orIEC 60228
Wiremake-up for:
0,14 mm = 18x0,1 mm
0,25 mm = 14x0,15 mm
0,34 mm = 7x0,25 mm
Special PVC core insulation TI2, to
DINVDE0281 part1
Core identification in accordance with DIN
47100, but without colour repetition
Cores stranded in layers with optimal
lay-lengths
Outer sheath from special full
polyurethane TMPU according to
DIN EN 50363-10-2
Colour light grey (RAL 7035)
with meter marking

Resistant to UV radiation, oxygen, ozone,


hydrolysis, microbes
Self-extinguishing and flame retardant in
accordance to VDE 0482-332-1-2, DIN EN
60332-1/ IEC 60332-1 (conforms to DIN VDE
0472 Part 804 Test method B)
The materials used in manufacture are free
of silicone, cadmium and substances that
impair paint wetting
Good cleaning properties
Resistant to all standard detergents


Note

Screened analogue type:


NANOFLEXHC TRONIC-C, see pageA95
*Hygienic Cable

Application
Special PUR data cable for the food and beverage industry; outer sheath with antimicrobial properties increases process reliability in all
applications in which food and beverages are processed unpacked and unsealed, e.g. processing of dairy products, meat, fish; production
of convenience foods, brewery and beverage industry
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
27164
27165
27166
27167
27168
27169
27170
27171
27172
27173
27174
27175
27176
27177
27178
27179

No.cores x
cross-sec.
mm
2x0,14
3x0,14
4x0,14
5x0,14
6x0,14
7x0,14
8x0,14
10x0,14
12x0,14
14x0,14
16x0,14
18x0,14
20x0,14
21x0,14
24x0,14
25x0,14

Outer
Cop.
approx. mm weight
kg/km
3,3
3,0
3,5
4,0
3,7
5,0
4,0
7,0
4,3
8,0
4,3
9,0
5,1
11,0
5,6
13,0
5,7
16,0
6,0
19,0
6,5
22,0
6,8
24,0
7,1
27,0
7,1
28,0
7,5
32,0
7,7
34,0

Weight
approx.
kg/km
13,0
16,0
19,0
22,0
25,0
28,0
35,0
41,0
48,0
53,0
59,0
65,0
70,0
77,0
87,0
91,0

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26


Part no.
27180
27181
27182
27183
27184
27185
27186
27187
27188
27189
27190
27191
27192
27193
27194
27195
27196

No.cores x
cross-sec.
mm
2x0,25
3x0,25
4x0,25
5x0,25
6x0,25
7x0,25
8x0,25
10x0,25
12x0,25
14x0,25
16x0,25
18x0,25
19x0,25
20x0,25
21x0,25
24x0,25
25x0,25

Outer
Cop.
approx. mm weight
kg/km
3,8
5,0
3,9
7,0
4,3
10,0
4,7
12,0
5,3
14,0
5,3
17,0
5,7
19,0
6,6
24,0
6,8
29,0
7,2
34,0
7,6
38,0
8,1
43,0
8,1
46,0
8,6
48,0
8,6
50,0
9,4
60,0
9,5
61,0

Weight
approx.
kg/km
18,0
22,0
26,0
30,0
36,0
42,0
49,0
57,0
66,0
75,0
84,0
72,0
84,0
101,0
107,0
120,0
132,0

AWG-No.
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24

Continuation

A 93
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NANOFLEX HC*TRONIC flexible, colour code to DIN 47100, meter marking



Part no.
27197
27198
27199
27200
27201
27202
27203
27204
27205
27206
27207
27208
27209
27210
27211
27212
27213
27214
27215
27216
27217

No.cores x
cross-sec.
mm
2x0,34
3x0,34
4x0,34
5x0,34
6x0,34
7x0,34
8x0,34
10x0,34
12x0,34
14x0,34
16x0,34
18x0,34
20x0,34
21x0,34
24x0,34
25x0,34
2x0,5
3x0,5
4x0,5
5x0,5
6x0,5

Outer
Cop.
approx. mm weight
kg/km
4,2
7,0
4,4
10,0
4,8
13,0
5,4
16,0
5,9
20,0
5,9
23,0
7,0
26,0
7,6
33,0
7,7
39,0
8,4
46,0
8,8
52,0
9,3
59,0
9,9
65,0
9,9
69,0
10,5
78,0
10,7
82,0
4,6
10,0
4,8
14,0
5,4
19,0
5,9
24,0
6,4
29,0

Weight
approx.
kg/km
22,0
30,0
43,0
54,0
58,0
61,0
73,0
82,0
102,0
108,0
126,0
143,0
160,0
166,0
186,0
192,0
40,0
46,0
55,0
64,0
73,0

AWG-No.
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
20
20
20
20
20


Part no.
27218
27219
27220
27221
27222
27223
27224
27225
27226
27227
27228
27229
27230
27231
27232
27233
27234

No.cores x
cross-sec.
mm
7x0,5
8x0,5
10x0,5
12x0,5
16x0,5
20x0,5
24x0,5
2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
8x0,75
10x0,75
12x0,75
16x0,75
20x0,75

Outer
Cop.
approx. mm weight
kg/km
6,4
34,0
7,2
38,0
8,4
48,0
8,4
58,0
10,0
77,0
11,2
96,0
11,8
116,0
5,2
14,0
5,4
22,0
5,9
29,0
6,7
36,0
7,3
50,0
8,6
58,0
9,6
72,0
9,7
86,0
11,6
115,0
12,4
144,0

Weight
approx.
kg/km
81,0
97,0
116,0
135,0
168,0
213,0
241,0
47,0
54,0
66,0
80,0
110,0
125,0
148,0
176,0
220,0
276,0

AWG-No.
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18

Dimensions and specifications may be changed without prior notice. (RA02)

A 94
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NANOFLEX HC*TRONIC-C EMC preferred type, flexible, colour code to


DIN 47100, screened, meter marking


Technical data

Cable structure

Properties

Special polyurethane data cables for


electronic control according to DIN VDE
0245, 0812 
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Peak operating voltage
(not for purposes of high current and
power installation)
0,14 mm = 350 V
>=0,25 mm = 500 V
Test voltage
core/core 1200 V
core/screen 800 V
Breakdown voltage
min. 2400 V
Insulation resistance
min. 200 MOhm x km
Operating capacity
(approx.-value) at 800 Hz
core/core at 0,14 mm = 120 pF/m
core/core >=0,25 mm = 150 pF/m
core/screen at 0,14 mm = 240 pF/m
core/screen >=0,25 mm = 270 pF/m
Inductance approx. 0,65 mH/km
Impedance approx. 78 Ohm
Coupling resistance max. 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 100x106 cJ/kg (up to100 Mrad)

Bare copper conductor, fine wire stranded


from 0,5 mm according to DIN VDE 0295
cl.5 or 0245 or IEC 60228 
Wire make-up for:
0,14 mm = 18x0,1 mm
0,25 mm = 14x0,15 mm
0,34 mm = 7x0,25 mm
Special PVC core insulation TI2, accordingto
DINVDE 0281 part 1
Core identification according to DIN 47100,
but without colour repetition
Cores stranded in layers with optimal
lay-lengths
Foil wrapping
Drain stranded wire, tinned copper
Tinned copper braided screening, coverage
approx. 85%
Outer sheath from special full polyurethane
TMPU according to DIN EN 50363-10-2
Sheath colour - light grey (RAL 7035)
With meter marking

Resistant to UV radiation, oxygen, ozone,


hydrolysis, microbes
Self-extinguishing and flame retardant in
accordance to VDE 0482-332-1-2, DIN EN
60332-1/ IEC 60332-1 (conforms to DIN VDE
0472 Part 804 Test method B)
The materials used in manufacture are free
of silicone, cadmium and substances that
impair paint wetting
Good cleaning properties
Resistant to all standard detergents


Note

unscreened analogue type:


NANOFLEXHC TRONIC, see pageA93
*Hygienic Cable

Application
Special PUR cable for the food and beverage industry; outer sheath with antimicrobial properties increases process reliability in all applications
in which food and beverages are processed unpacked and unsealed, e.g. processing of dairy products, meat, fish; production of convenience
foods, brewery and beverage industry
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
27235
27236
27237
27238
27239
27240
27241
27242
27243
27244
27245
27246
27247
27248
27249
27250
27251

No.cores x
cross-sec.
mm
1x0,14
2x0,14
3x0,14
4x0,14
5x0,14
6x0,14
7x0,14
8x0,14
10x0,14
12x0,14
14x0,14
16x0,14
18x0,14
20x0,14
21x0,14
24x0,14
25x0,14

Outer
Cop.
approx. mm weight
kg/km
2,5
6,0
3,7
12,0
3,9
13,0
4,1
15,0
4,4
16,0
4,9
18,0
4,9
19,0
5,2
21,0
6,2
29,0
6,2
31,0
6,6
32,0
6,9
43,0
7,2
51,0
7,7
55,0
7,9
56,0
8,3
62,0
8,5
61,0

Weight
approx.
kg/km
16,0
20,0
27,0
32,0
37,0
42,0
48,0
55,0
65,0
77,0
79,0
89,0
103,0
116,0
120,0
131,0
136,0

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26


Part no.
27252
27253
27254
27255
27256
27257
27258
27259
27260
27261
27262
27263
27264
27265
27266
27267
27268

No.cores x
cross-sec.
mm
1x0,25
2x0,25
3x0,25
4x0,25
5x0,25
6x0,25
7x0,25
8x0,25
10x0,25
12x0,25
14x0,25
16x0,25
18x0,25
19x0,25
20x0,25
21x0,25
24x0,25

Outer
Cop.
approx. mm weight
kg/km
2,9
7,0
4,2
16,0
4,3
19,0
4,7
22,0
5,3
27,0
5,7
32,0
5,7
35,0
6,6
42,0
7,2
50,0
7,3
58,0
7,9
62,0
8,3
67,0
8,9
78,0
9,1
79,0
9,4
152,0
9,4
91,0
10,0
96,0

Weight
approx.
kg/km
27,0
31,0
36,0
40,0
51,0
58,0
64,0
82,0
85,0
90,0
144,0
110,0
142,0
146,0
88,0
150,0
163,0

AWG-No.
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24

Continuation

A 95
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NANOFLEX HC*TRONIC-C EMC preferred type, flexible, colour code to


DIN 47100, screened, meter marking

Part no.
27269
27270
27271
27272
27273
27274
27275
27276
27277
27278
27279
27280
27281
27282
27283
27284
27285
27286
27287
27288
27289
27290
27291
27292
27293

No.cores x
cross-sec.
mm
25x0,25
1x0,34
2x0,34
3x0,34
4x0,34
5x0,34
6x0,34
7x0,34
8x0,34
10x0,34
12x0,34
14x0,34
16x0,34
18x0,34
19x0,34
20x0,34
21x0,34
24x0,34
25x0,34
1x0,5
2x0,5
3x0,5
4x0,5
5x0,5
6x0,5

Outer
Cop.
approx. mm weight
kg/km
10,1
99,0
3,2
13,0
4,8
18,0
5,2
22,0
5,5
28,0
6,0
31,0
6,7
45,0
6,7
51,0
7,8
54,0
8,4
65,0
8,5
70,0
9,0
81,0
9,4
88,0
9,8
103,0
10,1
106,0
10,1
112,0
10,7
116,0
10,7
129,0
12,0
120,0
3,4
15,0
5,3
29,0
5,6
39,0
6,0
46,0
6,7
52,0
7,3
66,0

Weight
approx.
kg/km
169,0
24,0
30,0
37,0
48,0
54,0
61,0
67,0
81,0
103,0
110,0
153,0
159,0
172,0
181,0
191,0
199,0
229,0
241,0
40,0
45,0
55,0
61,0
76,0
89,0

AWG-No.
24
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
20
20
20
20
20
20


Part no.
27294
27295
27296
27297
27298
27299
27300
27301
27302
27303
27304
27305
27306
27307
27308
27309
27310
27311
27312
27313
27314
27315
27316
27317
27318
27319
27320
27321

No.cores x
cross-sec.
mm
7x0,5
8x0,5
10x0,5
12x0,5
14x0,5
16x0,5
18x0,5
19x0,5
20x0,5
24x0,5
25x0,5
1x0,75
2x0,75
3x0,75
4x0,75
5x0,75
6x0,75
7x0,75
8x0,75
10x0,75
12x0,75
14x0,75
16x0,75
18x0,75
19x0,75
20x0,75
24x0,75
25x0,75

Outer
Cop.
approx. mm weight
kg/km
7,3
68,0
8,5
80,0
9,2
93,0
9,5
117,0
10,0
122,0
10,6
129,0
10,7
152,0
11,2
156,0
11,9
173,0
12,6
256,0
12,7
250,0
3,8
19,0
6,0
38,0
6,2
50,0
6,7
57,0
7,3
70,0
8,1
87,0
8,2
96,0
9,0
110,0
10,3
140,0
10,4
151,0
11,2
167,0
11,8
183,0
12,6
207,0
12,6
221,0
13,1
238,0
14,1
270,0
14,3
278,0

Weight
approx.
kg/km
98,0
117,0
135,0
157,0
190,0
210,0
217,0
246,0
275,0
337,0
351,0
41,0
59,0
66,0
77,0
93,0
113,0
130,0
145,0
180,0
202,0
225,0
275,0
292,0
322,0
362,0
435,0
415,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18

Dimensions and specifications may be changed without prior notice. (RA02)

A 96
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Data and Computer Cables

B1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Data and Computer Cables


Due to the increasing data transfer between
machines and equipment the higher standards in
data and computer applications are necessary.
Besides standard processes the requirement
of precise data transfer must be the rst and
foremost.
Depending on the requirement, the HELUKABEL
customer can choose the data or computer cable
from an extensive stock, where almost all cable
constructions are ex stock.
Depending on the required application, solid,
exible or highly exible constructions with
corresponding screening may be necessary.
In this case our technical advisors are ready to
inform you.
We can also manufacture cables according to your
specic requirements with a minimum order
quantity. For special enquiries please ll-in our
attached enquiry form.
C

B2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description

Page

TRONIC (LiYY),flexible, colour coded to DIN 47100, meter marking................................................................................................................


PAAR-TRONIC,flexible, colour coded to DIN 47100, meter marking ..............................................................................................................

DATAFLAMM,halogen-free, meter marking ................................................................................................................................................


TRONIC-CY (LiY-CY),flexible, Cu-screened, colour coded to DIN 47100, EMC-preferred type, meter marking...........................................................

PAAR-TRONIC-CY,flexible, Cu-screened, colour coded to DIN 47100, EMC-preferred type, meter marking .............................................................

PAAR-CY-OZ,flexible, Cu-screened, EMC-preferred type, meter marking ........................................................................................................

PAAR-TRONIC-CY-CY (LiYCY-CY),EMC-preferred type, meter marking .........................................................................................................


PAAR-TRONIC-Li-2YCYv,PE-insulated, low capacitance, Termi-Point, EMC-preferred type, meter marking ...............................................................

PAAR-TRONIC-Li-2YCY,PE-insulated, low capacitance, Termi-Point, EMC-preferred type, meter marking .................................................................

LifYCY,high flexible, paired, screened, EMC-preferred type, meter marking ...........................................................................................................


TRONIC 1-CY,each core individually screened, EMC-preferred type, meter marking ................................................................................................
TRONIC 2-CY,2 cores screened, meter marking ...........................................................................................................................................

LiY-TPC-Y,pairs screened, EMC-preferred type, meter marking .........................................................................................................................


DATAPUR-C,EMC-preferred type, Cu-screened, PUR-outer jacket, meter marking ..................................................................................................

DATAFLAMM-C,EMC-preferred type, halogen-free, screened, meter marking......................................................................................................


DATAFLAMM-C-PAAR,EMC-preferred type, halogen-free, screened, meter marking............................................................................................

EDV-PiMF-CY,PE-insulated, low capacitance, EMC-preferred type, meter marking ................................................................................................


RD-Y(St)Y,Instrumentation Cable suitable for Maxi-Term-Point-connection,

.....................................................................................
RD-Y(St)Yv / RD-Y(St)YY,reinforced (double) outer jacket, instrumentation cable, Maxi-Termi-Point , meter marking ...................................................
RE-2Y(St)Yv,instrumentation cable, reinforced outer jacket, meter marking ....................................................................................................
RE-2Y(St)Yv PiMF,Instrumentation cable, pairs screened, reinforced outer jacket, meter marking .......................................................................
J-2Y(St)Y,St III Bd 16 Mbits/s (Kat. 3) ISDN/EDV (Z = 100 Ohm), meter marking ........................................................................................................
JE-Y(St)Y,Bd Si Industry-Elektronic Cable according to DIN VDE 0815 ..............................................................................................................
JE-LiYCY,Bd Si Industry-Elektronic Cable according to DIN VDE 0815 ...............................................................................................................
JE-LiHCH,Bd industry electronic cable, halogen-free, accordingtoVDE0815 ....................................................................................................
RD-H(ST)H,Bd instrumentation cable, halogen-free ........................................................................................................................................
meter marking

B 4
B 6
B 8
B 9

B 11
B 13
B 14
B 16
B 17
B 18
B 19
B 20
B 21
B 22
B 23
B 24
B 25
B 26
B 27
B 28
B 29
B 30
B 31
B 32
B 33
B 34

B3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRONIC (LiYY)

flexible, colour coded to DIN 47100, meter marking

Technical data

Cable structure

Properties

Special PVC data cables, adapted to


DINVDE0812
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage
(not for purposes of high current and
power installation)
0,14 mm = 350 V
0,25 mm = 500 V
Test voltage
up to 0,25 mm 1200 V
from 0,34 mm 2000 V
Breakdown voltage
up to 0,25 mm 2400 V
from 0,34 mm 4000 V
Insulation resistance
min. 20 MOhm x km
Capacitance (approx.-value) at 800 Hz
0,14 mm 120 pF/m
0,25 mm 150 pF/m
Inductance approx. 0,65 mH/km
Impedance approx. 78 Ohm
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5 and
IEC60228 cl.5
Conductor make-up for
0,14mm = 18x0,1mm
0,25mm = 14x0,15mm
0,34mm = 7x0,25mm
Special PVC core insulation TI2, to
DINVDE0281 part1
Colour coded to DIN 47100, but without
colour repetition
Cores stranded in layers with optimal
lay-length
Special PVC outer sheath TM2, to
DINVDE0281 part1
Colour grey (RAL7001)
with meter marking, change-over in 2011

Extremely oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
HELUKABEL-TRONIC is also available in
paired version (e.g.
HELUKABEL-PAAR-TRONIC20x2x0,14mm).
screened analogue type:
TRONIC-CY (LiY-CY), see page B 9

Application
These cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist and wet rooms but
not suitable for open air, wherever the construction requirements call for a minimum outer diameter, TRONIC is the suitable cable to use.
This applies especially to such areas as tool making and machine industries as well as electronic, computer, measurement and control sectors.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
18001
18002
18003
18004
18005
18006
18007
18008
18009
18010
18011
18012
18013
18014
18015
18117
18016
18017
18018
18019
18020
18021
18022
18023
18024
18025
18026
18027
18028

No.cores x
cross-sec.
mm
2x0,14
3x0,14
4x0,14
5x0,14
6x0,14
7x0,14
8x0,14
10x0,14
12x0,14
14x0,14
16x0,14
18x0,14
20x0,14
21x0,14
24x0,14
25x0,14
27x0,14
30x0,14
32x0,14
36x0,14
40x0,14
42x0,14
44x0,14
48x0,14
52x0,14
56x0,14
61x0,14
80x0,14
100x0,14

Outer
Cop.
approx. mm weight
kg/km
3,3
2,7
3,5
4,0
3,7
5,4
4,0
6,7
4,3
8,1
4,3
9,4
5,1
10,7
5,6
13,4
5,7
16,1
6,0
18,8
6,5
21,5
6,8
24,2
7,1
26,9
7,1
28,2
7,5
32,3
7,7
33,6
7,7
36,3
8,5
40,3
8,8
43,0
9,3
48,4
9,6
54,0
9,9
56,0
10,4
59,0
10,5
65,0
11,0
70,0
11,3
75,0
11,6
82,0
13,0
108,0
14,7
135,0

Weight
approx.
kg/km
13,0
16,0
19,0
22,0
25,0
28,0
35,0
41,0
48,0
53,0
59,0
65,0
70,0
77,0
87,0
91,0
97,0
108,0
114,0
126,0
139,0
146,0
153,0
164,0
173,0
187,0
204,0
280,0
370,0

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26


Part no.
18029
18030
18031
18032
18033
18034
18035
18036
18037
18038
18039
18040
18114
18041
18042
18043
18118
18044
18045
18046
18047
18115
18048
18049
18050
18051
18052
18053
18054

No.cores x
cross-sec.
mm
2x0,25
3x0,25
4x0,25
5x0,25
6x0,25
7x0,25
8x0,25
10x0,25
12x0,25
14x0,25
16x0,25
18x0,25
19x0,25
20x0,25
21x0,25
24x0,25
25x0,25
27x0,25
30x0,25
32x0,25
36x0,25
37x0,25
40x0,25
42x0,25
44x0,25
48x0,25
52x0,25
56x0,25
61x0,25

Outer
Cop.
approx. mm weight
kg/km
3,8
4,8
3,9
7,2
4,3
9,6
4,7
12,0
5,3
14,4
5,3
16,8
5,7
19,2
6,6
24,0
6,8
28,8
7,2
33,6
7,6
38,4
8,1
43,2
8,1
46,0
8,6
48,0
8,6
50,0
9,4
60,0
9,5
61,0
9,5
65,0
10,3
72,0
10,9
77,0
11,3
86,0
11,3
89,0
11,6
96,0
12,0
101,0
12,6
106,0
12,7
115,0
13,3
125,0
13,9
134,0
14,3
146,0

Weight
approx.
kg/km
18,0
22,0
26,0
30,0
36,0
42,0
49,0
57,0
66,0
75,0
84,0
72,0
84,0
101,0
107,0
120,0
132,0
140,0
156,0
164,0
182,0
190,0
200,0
211,0
225,0
245,0
263,0
280,0
305,0

AWG-No.
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24

Continuation

B4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRONIC (LiYY)

flexible, colour coded to DIN 47100, meter marking

Part no.
18055
18056
18057
18058
18059
18060
18061
18062
18063
18064
18065
18066
18067
18068
18069
18070
18071
18096
18072
18073
18074
18075
18116
18076
18077
18078
18079
18080
18081
18082
18083
18084

No.cores x
cross-sec.
mm
80x0,25
100x0,25
2x0,34
3x0,34
4x0,34
5x0,34
6x0,34
7x0,34
8x0,34
10x0,34
12x0,34
14x0,34
16x0,34
18x0,34
20x0,34
21x0,34
24x0,34
25x0,34
27x0,34
30x0,34
32x0,34
36x0,34
37x0,34
40x0,34
42x0,34
44x0,34
48x0,34
52x0,34
53x0,34
61x0,34
80x0,34
100x0,34

Outer
Cop.
approx. mm weight
kg/km
16,5
192,0
18,2
240,0
4,2
6,5
4,4
9,8
4,8
13,1
5,4
16,3
5,9
19,6
5,9
22,8
7,0
26,1
7,6
32,6
7,7
39,2
8,4
45,7
8,8
52,0
9,3
59,0
9,9
65,0
9,9
69,0
10,5
78,0
10,7
82,0
10,7
88,0
11,8
98,0
11,8
104,0
12,9
118,0
12,9
121,0
13,3
131,0
14,0
137,0
14,0
144,0
14,7
157,0
15,4
170,0
15,4
183,0
16,3
199,0
18,8
264,0
21,0
327,0

Weight
approx.
kg/km
450,0
590,0
22,0
30,0
43,0
54,0
58,0
61,0
73,0
82,0
102,0
108,0
126,0
143,0
160,0
166,0
186,0
192,0
206,0
226,0
245,0
285,0
292,0
318,0
330,0
370,0
405,0
430,0
440,0
610,0
880,0
1050,0

AWG-No.
24
24
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22


Part no.
18085
18086
18087
18088
18089
18090
18091
18092
18093
18103
18101
18094
18102
18095
18104
18097
18098
18099
18100
18105
18106
18107
18108
18109
18110
18111
18112
18113

No.cores x
cross-sec.
mm
2x0,5
3x0,5
4x0,5
5x0,5
6x0,5
7x0,5
8x0,5
10x0,5
12x0,5
16x0,5
20x0,5
24x0,5
30x0,5
40x0,5
2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
8x0,75
10x0,75
12x0,75
16x0,75
20x0,75
2x1
3x1
2x1,5
3x1,5

Outer
Cop.
approx. mm weight
kg/km
4,6
9,6
4,8
14,4
5,4
19,2
5,9
24,0
6,4
28,8
6,4
33,6
7,2
38,4
8,4
48,0
8,4
58,0
10,0
77,0
11,2
96,0
11,8
116,0
13,2
144,0
15,2
192,0
5,2
14,4
5,4
21,6
5,9
29,0
6,7
36,0
7,3
50,0
8,6
58,0
9,6
72,0
9,7
86,0
11,1
115,0
12,4
144,0
5,5
19,2
5,8
29,0
6,2
29,0
6,7
43,0

Weight
approx.
kg/km
40,0
46,0
55,0
64,0
73,0
81,0
97,0
116,0
135,0
168,0
213,0
241,0
303,0
391,0
47,0
54,0
66,0
80,0
110,0
125,0
148,0
176,0
220,0
276,0
56,0
71,0
75,0
90,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
17
17
16
16

Dimensions and specifications may be changed without prior notice. (RB01)

Standardised process control and visualisation


of an extrusion system at our Windsbach factory.

B5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PAAR-TRONIC

flexible, colour coded to DIN 47100, meter marking

Technical data

Cable structure

Properties

Special PVC data cables, adapted to


DINVDE0812,0814
Temperature range
flexing -5 C to +80 C
fixed installation -30 C to +80 C
Nominal voltage 250 V
Test voltage 1200 V
Breakdown voltage min. 2400 V
Insulation resistance
min. 20 MOhm x km
Capacitance (approx.-value) at 800 Hz
core/core 0,14 mm = 120 pF/m
core/core 0,25 mm = 150 pF/m
Load 0,14 mm = 1,5 A
0,25 mm = 2,5 A
Inductance approx. 0,65 mH/km
Impedance approx. 78 Ohm
K1-coupling approx. 300 pF/100 m
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5 and
IEC60228 cl.5
Special PVC core insulation YI2, to
DINVDE0207 part4
Colour coded to DIN47100
Cores stranded in pairs with optimal
lay-length
Pairs stranded in layers with optimal
lay-length
Core wrapping with foil
Special PVC outer sheath YM2, to
DINVDE0207 part5
Sheath colour grey (RAL7032)
with meter marking, change-over in 2011

Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
screened analogue type:
PAAR-TRONIC-CY, see page B 11

Application
These data control cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist and wet
rooms but not suitable for open air. PAAR-TRONIC is the perfect cable for use in areas where a small diameter is essential to complete wiring.
E. g. as a control and signal cable in measuring instruments, computers, signal transfer etc. This cable is suitable only for low load application.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
19001
19002
19003
19004
19005
19006
19007
19008
19009
19010
19011
19012
19013
19014
19015
19016
19017

No.pairs x
cross-sec.
mm
1 x 2 x 0,14
2 x 2 x 0,14
3 x 2 x 0,14
4 x 2 x 0,14
5 x 2 x 0,14
6 x 2 x 0,14
7 x 2 x 0,14
8 x 2 x 0,14
10 x 2 x 0,14
11 x 2 x 0,14
12 x 2 x 0,14
14 x 2 x 0,14
15 x 2 x 0,14
16 x 2 x 0,14
18 x 2 x 0,14
20 x 2 x 0,14
22 x 2 x 0,14

Outer
Cop.
approx. mm weight
kg/km
3,5
2,7
5,1
5,4
5,2
8,0
5,6
10,7
6,6
13,4
6,9
16,1
6,9
18,8
7,5
21,5
8,6
26,9
8,7
29,5
8,9
32,3
9,6
37,6
9,8
40,3
10,1
43,0
10,4
48,4
10,8
54,0
11,6
59,0

Weight
approx.
kg/km
20,0
25,0
31,0
38,0
45,0
50,0
57,0
64,0
78,0
86,0
94,0
105,0
108,0
110,0
119,0
130,0
150,0

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26


Part no.
19018
19019
19020
19021
19022
19023
19024
19025
19026
19027
19028
19029
19030
19031
19032
19033

No.pairs x
cross-sec.
mm
24 x 2 x 0,14
25 x 2 x 0,14
26 x 2 x 0,14
27 x 2 x 0,14
28 x 2 x 0,14
30 x 2 x 0,14
32 x 2 x 0,14
34 x 2 x 0,14
36 x 2 x 0,14
38 x 2 x 0,14
40 x 2 x 0,14
44 x 2 x 0,14
45 x 2 x 0,14
50 x 2 x 0,14
52 x 2 x 0,14
55 x 2 x 0,14

Outer
Cop.
approx. mm weight
kg/km
12,4
65,0
12,5
67,0
12,5
70,0
12,7
73,0
12,8
75,0
13,1
81,0
13,5
86,0
14,0
91,0
14,2
97,0
14,3
102,0
15,0
108,0
15,9
118,0
15,9
121,0
16,5
134,0
16,9
140,0
17,5
148,0

Weight
approx.
kg/km
170,0
180,0
184,0
188,0
192,0
200,0
224,0
247,0
260,0
272,0
294,0
334,0
342,0
387,0
403,0
427,0

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26

Continuation

B6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PAAR-TRONIC

flexible, colour coded to DIN 47100, meter marking

Part no.
19034
19035
19036
19037
19038
19039
19040
19041
19042
19043
19044
19045
19046
19047
19048
19049
19050
19051
19052
19053
19054
19055
19056

No.pairs x
cross-sec.
mm
1 x 2 x 0,25
2 x 2 x 0,25
3 x 2 x 0,25
4 x 2 x 0,25
5 x 2 x 0,25
6 x 2 x 0,25
7 x 2 x 0,25
8 x 2 x 0,25
10 x 2 x 0,25
11 x 2 x 0,25
12 x 2 x 0,25
14 x 2 x 0,25
15 x 2 x 0,25
16 x 2 x 0,25
18 x 2 x 0,25
20 x 2 x 0,25
22 x 2 x 0,25
24 x 2 x 0,25
25 x 2 x 0,25
26 x 2 x 0,25
27 x 2 x 0,25
28 x 2 x 0,25
30 x 2 x 0,25

Outer
Cop.
approx. mm weight
kg/km
4,0
5,0
6,0
10,0
6,3
15,0
6,8
20,0
7,8
25,0
8,3
30,0
8,3
35,0
9,3
40,0
10,5
50,0
10,6
55,0
10,8
60,0
11,6
70,0
12,0
75,0
12,5
80,0
12,8
90,0
13,3
100,0
14,0
110,0
15,0
120,0
15,3
125,0
15,3
130,0
15,5
135,0
15,7
140,0
16,1
150,0

Weight
approx.
kg/km
32,0
37,0
47,0
58,0
70,0
80,0
89,0
99,0
114,0
126,0
137,0
161,0
174,0
187,0
212,0
234,0
250,0
280,0
300,0
320,0
330,0
345,0
370,0

AWG-No.
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24


Part no.
19057
19058
19059
19060
19061
19062
19063
19064
19065
19066
19067
19068
19069
19070
19071
19072
19073
19074
19075
19076
19077
19078

No.pairs x
cross-sec.
mm
32 x 2 x 0,25
34 x 2 x 0,25
36 x 2 x 0,25
38 x 2 x 0,25
40 x 2 x 0,25
44 x 2 x 0,25
45 x 2 x 0,25
50 x 2 x 0,25
52 x 2 x 0,25
55 x 2 x 0,25
1 x 2 x 0,34
2 x 2 x 0,34
3 x 2 x 0,34
4 x 2 x 0,34
1 x 2 x 0,5
2 x 2 x 0,5
3 x 2 x 0,5
4 x 2 x 0,5
1 x 2 x 0,75
2 x 2 x 0,75
3 x 2 x 0,75
4 x 2 x 0,75

Outer
Cop.
approx. mm weight
kg/km
16,5
160,0
17,2
170,0
17,3
180,0
17,6
190,0
18,3
200,0
19,7
220,0
19,7
225,0
20,4
250,0
20,8
260,0
21,5
275,0
4,4
6,5
6,9
13,1
7,0
19,6
7,8
26,1
4,6
9,6
7,6
19,2
7,7
28,8
8,6
38,4
5,2
14,4
8,5
28,8
8,6
43,2
9,6
57,6

Weight
approx.
kg/km
410,0
425,0
440,0
480,0
530,0
580,0
600,0
650,0
670,0
790,0
36,0
42,0
50,0
61,0
42,0
51,0
62,0
73,0
47,0
59,0
74,0
93,0

AWG-No.
24
24
24
24
24
24
24
24
24
24
22
22
22
22
20
20
20
20
18
18
18
18

Dimensions and specifications may be changed without prior notice. (RB01)

Drag Chain Systems


Open chains
Closed chains
Accessories
Installation instructions
Selection tables

You can nd drag chain systems in our catalogue Cable Accessories.

B7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

DATAFLAMM

halogen-free, meter marking

Technical data

Cable structure

Properties

Special data cable


Temperature range
flexing +5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage
0,14 mm = 350 V
>0,14 mm = 500 V
Test voltage
0,14 mm = 800 V
>0,14 mm = 1200 V
Insulation resistance
min. 2 GOhm x km
Capacitance
core/core <70 nF/km
Minimum bending radius
approx. 7,5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors to


DINVDE0812, conductor make-up for
0,34mm - 7x0,25mm
PE-insulation, compound type 2YJ1 to
DINVDE0207 part2
Cores colour coded to DIN47100
Cores twisted in layers with optimal
lay-length
Halogen-free outer sheath, to
DINVDE0207 part24, compound type HM2
Sheath colour grey, RAL 7005
with meter marking, change-over in 2011

Halogen-free according to VDE0482


part267/ DINEN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Halogen-free sheath compound,
self-extinguishing and flame retardant
according to DINVDE0482 part265-2-1/
EN50265-2-1/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)


Note

screened analogue type:


DATAFLAMM-C, see page B 23

Application
DATAFLAMM halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom
speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable
for installation in dry, damp and wet environments as well as in masonry and concrete.
PE-insulated-cores, compared with the conventional PVC-insulated cores, assure a remarkable and more favourable capacitance values.
These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading
centres where the freedom from halogen in case of fire and the flame propagation must be avoided.
The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
52300
52301
52302
52303
52304
52305
52306
52307
52308
52309
52310
52311
52312
52313
52314
52315
52316
52317
52318
52319
52320
52321
52322
52323
52324
52430
52431
52325
52326
52327
52328
52329

No.cores x
cross-sec.
mm
2x0,14
3x0,14
4x0,14
5x0,14
6x0,14
7x0,14
8x0,14
10x0,14
12x0,14
15x0,14
18x0,14
21x0,14
25x0,14
30x0,14
34x0,14
40x0,14
50x0,14
2x0,25
3x0,25
4x0,25
5x0,25
7x0,25
10x0,25
12x0,25
15x0,25
18x0,25
21x0,25
25x0,25
34x0,25
40x0,25
2x0,34
3x0,34

Outer
Cop.
approx. mm weight
kg/km
3,3
2,6
3,5
4,0
3,7
5,3
4,0
6,6
4,3
7,9
4,3
9,2
4,6
10,3
5,4
13,2
5,7
16,0
6,2
20,1
6,7
23,7
7,3
27,9
7,9
33,4
8,1
39,3
8,9
45,5
9,5
53,6
10,5
64,9
3,7
4,7
3,9
7,1
4,2
9,5
4,6
12,0
5,1
16,6
6,4
24,0
6,5
28,6
7,3
36,0
7,8
43,2
8,3
50,4
9,3
59,8
10,8
81,3
11,7
96,0
4,3
6,4
4,5
9,7

Weight
approx.
kg/km
14,0
17,0
19,0
23,0
25,0
27,0
30,0
38,0
45,0
57,0
65,0
76,0
88,0
98,0
111,0
139,0
764,0
18,0
21,0
26,0
31,0
40,0
56,0
64,0
80,0
90,0
105,0
121,0
168,0
196,0
25,0
30,0

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
24
24
24
24
24
24
24
24
24
24
24
24
24
22
22


Part no.
52330
52331
52332
52333
52334
52335
52336
52337
52338
52339
52340
52341
52342
52343
52344
52345
52346
52347
52348
52349
52350
52351
52352
52353
52354
52355
52356
52357
52358
52359
52360
52361

No.cores x
cross-sec.
mm
4x0,34
5x0,34
7x0,34
10x0,34
12x0,34
15x0,34
18x0,34
21x0,34
25x0,34
34x0,34
40x0,34
2x0,5
3x0,5
4x0,5
5x0,5
7x0,5
10x0,5
12x0,5
15x0,5
18x0,5
21x0,5
25x0,5
30x0,5
34x0,5
40x0,5
2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
10x0,75
12x0,75

Outer
Cop.
approx. mm weight
kg/km
4,9
13,0
5,4
16,4
5,9
22,7
7,8
32,4
8,0
39,1
9,0
49,1
9,6
59,1
10,1
68,3
11,9
81,4
13,3
111,1
14,4
130,5
4,6
9,5
4,9
14,2
5,3
19,2
5,9
24,0
6,4
33,7
8,4
48,0
8,6
57,4
9,8
72,0
10,5
86,4
11,1
101,0
12,6
120,0
13,3
142,6
14,5
163,1
15,8
192,0
5,2
14,3
5,5
21,5
6,0
28,6
6,7
36,1
7,3
50,3
9,8
72,0
10,0
86,2

Weight
approx.
kg/km
35,0
43,0
58,0
80,0
91,0
115,0
135,0
154,0
180,0
233,0
272,0
30,0
36,0
43,0
56,0
70,0
101,0
117,0
145,0
171,0
197,0
230,0
269,0
301,0
365,0
40,0
51,0
61,0
76,0
97,0
137,0
167,0

AWG-No.
22
22
22
22
22
22
22
22
22
22
22
20
20
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18

Dimensions and specifications may be changed without prior notice. (RB01)

B8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRONIC-CY (LiY-CY)

flexible, Cu-screened, colour coded to DIN 47100,

EMC-preferred type, meter marking




Technical data

Cable structure

Properties

Special PVC data screened cables, adapted


to DINVDE
0812
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage
0,14 mm = 350 V
0,25 mm = 500 V
Test voltage
core/core 1200 V
core/screen 800 V
Breakdown voltage min. 2400 V
Insulation resistance
min. 200 MOhm x km
Capacitance (approx.-value) at 800 Hz
core/core at 0,14 mm = 120 pF/m
core/core 0,25 mm = 150 pF/m
core/screen at 0,14 mm = 240 pF/m
core/screen 0,25 mm = 270 pF/m
Load (A) According to different
cross-sections, see table
Technical Information
Inductance approx. 0,65 mH/km
Impedance approx. 78 Ohm
Coupling resistance max. 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors for


0,5mm to DINVDE0295 cl.5 and
IEC60228 cl.5
Conductor make-up for
0,14mm = 18x0,1mm
0,25mm = 14x0,15mm
0,34mm = 7x0,25mm
Special PVC core insulation TI2, to
DINVDE0281 part1
Cores stranded in layers with optimal
lay-length
Colour coded to DIN 47100, but without
colour repetition
Core wrapping with foil
Drain-wire, tinned
Tinned, copper braided screen, approx.
85% coverage
Special PVC outer sheath TM2, to
DINVDE0281 part1
Colour grey (RAL7001)
with meter marking, change-over in 2011


Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

HELUKABEL-TRONIC-CY is also available in


paired version
(e.g. HELUKABEL-PAAR-TRONIC-CY
16x2x0,14 mm).
For 1 core cable screen of helically wound.
unscreened analogue type:
TRONIC (LiYY), see page B 4

Application
These screened cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist and wet
rooms but not suitable for open air, wherever the construction requirements call for a minimum outer diameter, TRONIC is the suitable
cable to use. This applies especially to such areas as tool making and machine industries as well as electronic, computer, measurement and
control sectors.
The extremely small outer diameter make suitable for miniature plugs etc.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
20139
20001
20002
20003
20004
20005
20006
20007
20008
20009
20010
20011
20012
20013
20014

No.cores x
cross-sec.
mm
1x0,14
2x0,14
3x0,14
4x0,14
5x0,14
6x0,14
7x0,14
8x0,14
10x0,14
12x0,14
14x0,14
16x0,14
18x0,14
20x0,14
21x0,14

Outer
Cop.
approx. mm weight
kg/km
2,5
6,1
3,7
12,0
3,9
13,0
4,1
14,5
4,4
15,5
4,9
18,2
4,9
19,0
5,2
21,3
6,2
28,7
6,2
30,5
6,6
32,0
6,9
43,2
7,2
51,0
7,7
55,0
7,9
56,0

Weight
approx.
kg/km
16,0
20,0
27,0
32,0
37,0
42,0
48,0
55,0
65,0
77,0
79,0
89,0
103,0
116,0
120,0

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26


Part no.
20015
20091
20016
20017
20018
20019
20020
20021
20022
20023
20024
20025
20026
20027
20028

No.cores x
cross-sec.
mm
24x0,14
25x0,14
27x0,14
30x0,14
32x0,14
36x0,14
40x0,14
42x0,14
44x0,14
48x0,14
52x0,14
56x0,14
61x0,14
80x0,14
100x0,14

Outer
Cop.
approx. mm weight
kg/km
8,3
62,0
8,5
61,0
8,5
65,0
9,3
69,0
9,6
76,0
9,9
83,0
10,2
88,0
10,5
94,0
11,2
110,0
11,3
115,0
11,8
124,0
12,1
132,0
12,4
146,0
14,1
226,0
15,6
267,0

Weight
approx.
kg/km
131,0
136,0
142,0
157,0
163,0
182,0
209,0
217,0
226,0
240,0
270,0
320,0
370,0
510,0
580,0

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26

Continuation

B9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRONIC-CY (LiY-CY)

flexible, Cu-screened, colour coded to DIN 47100,

EMC-preferred type, meter marking

Part no.
20084
20029
20030
20031
20032
20083
20033
20034
20035
20036
20037
20038
20039
20086
20040
20041
20042
20092
20043
20044
20045
20046
20087
20047
20048
20049
20050
20051
20052
20053
20054
20055
20088
20056
20057
20058
20059
20085
20060
20061
20062
20063
20064
20065
20066
20089
20067
20068
20069
20093
20070
20071
20072
20073
20090
20074
20075
20076
20077
20078
20079
20080
20081
20082
16001
16002
16003
16004
16005
16006
16007
16008
16009
16010
16011

No.cores x
cross-sec.
mm
1x0,25
2x0,25
3x0,25
4x0,25
5x0,25
6x0,25
7x0,25
8x0,25
10x0,25
12x0,25
14x0,25
16x0,25
18x0,25
19x0,25
20x0,25
21x0,25
24x0,25
25x0,25
27x0,25
30x0,25
32x0,25
36x0,25
37x0,25
40x0,25
42x0,25
44x0,25
48x0,25
52x0,25
56x0,25
61x0,25
80x0,25
100x0,25
1x0,34
2x0,34
3x0,34
4x0,34
5x0,34
6x0,34
7x0,34
8x0,34
10x0,34
12x0,34
14x0,34
16x0,34
18x0,34
19x0,34
20x0,34
21x0,34
24x0,34
25x0,34
27x0,34
30x0,34
32x0,34
36x0,34
37x0,34
40x0,34
42x0,34
44x0,34
48x0,34
52x0,34
56x0,34
61x0,34
80x0,34
100x0,34
1x0,5
2x0,5
3x0,5
4x0,5
5x0,5
6x0,5
7x0,5
8x0,5
10x0,5
12x0,5
14x0,5

Outer
Cop.
approx. mm weight
kg/km
2,9
7,2
4,2
15,8
4,3
18,6
4,7
22,0
5,3
26,5
5,7
32,4
5,7
35,0
6,3
42,1
7,2
49,9
7,3
58,0
7,9
62,0
8,3
67,0
9,1
78,0
9,1
79,0
9,4
88,0
9,4
91,0
10,0
96,0
10,1
99,0
10,1
122,0
11,1
132,0
11,5
138,0
11,9
146,0
11,9
152,0
12,4
157,0
12,8
160,0
13,6
164,0
13,7
164,0
14,1
175,0
14,5
189,0
15,1
204,0
17,1
387,0
19,1
505,0
3,2
13,5
5,0
18,0
5,2
22,0
5,6
28,0
6,0
31,0
6,7
45,0
6,7
51,0
7,2
54,0
8,4
65,0
8,5
70,0
9,0
81,0
9,6
88,0
10,1
103,0
10,1
106,0
10,7
112,0
10,7
116,0
11,3
129,0
11,5
120,0
11,5
138,0
12,6
158,0
13,0
163,0
13,7
178,0
13,7
192,0
14,2
198,0
14,8
203,0
15,4
214,0
15,6
227,0
16,2
242,0
16,6
267,0
17,1
295,0
19,4
524,0
21,7
620,0
3,6
15,0
5,5
29,0
5,7
39,0
6,3
46,0
6,8
52,0
7,3
66,0
7,3
68,0
8,0
80,0
9,4
93,0
9,6
117,0
10,1
122,0

Weight
approx.
kg/km
27,0
31,0
36,0
40,0
51,0
58,0
64,0
82,0
85,0
90,0
144,0
110,0
142,0
146,0
152,0
150,0
163,0
169,0
176,0
189,0
204,0
219,0
230,0
247,0
269,0
292,0
317,0
330,0
343,0
365,0
480,0
605,0
24,0
30,0
37,0
48,0
54,0
61,0
67,0
81,0
103,0
110,0
153,0
159,0
172,0
181,0
191,0
199,0
229,0
241,0
258,0
290,0
305,0
330,0
348,0
364,0
389,0
414,0
420,0
450,0
480,0
520,0
580,0
694,0
40,0
45,0
55,0
61,0
76,0
89,0
98,0
117,0
135,0
157,0
190,0

AWG-No.
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
20
20
20
20
20
20
20
20
20
20
20


Part no.
16012
16013
16526
16014
16015
16016
16527
16017
16018
16164
16019
16528
16020
16021
16022
16023
16024
16025
16026
16027
16028
16029
16030
16031
16032
16033
16034
16035
16036
16037
16529
16038
16039
16040
16041
16042
16043
16163
16044
16530
16045
16120
16047
16048
16049
16475
16476
16477
16478
16479
16480
16481
16482
16483
16484
16485
16486
16487
16488
16489
16500
16501
16502
16503
16504
16505
16506
16507
16508
16509
16510
16511
16512
16513
16514

No.cores x
cross-sec.
mm
16x0,5
18x0,5
19x0,5
20x0,5
24x0,5
25x0,5
27x0,5
30x0,5
32x0,5
34x0,5
36x0,5
37x0,5
40x0,5
50x0,5
61x0,5
80x0,5
100x0,5
1x0,75
2x0,75
3x0,75
4x0,75
5x0,75
6x0,75
7x0,75
8x0,75
10x0,75
12x0,75
14x0,75
16x0,75
18x0,75
19x0,75
20x0,75
24x0,75
25x0,75
27x0,75
30x0,75
32x0,75
34x0,75
36x0,75
37x0,75
40x0,75
42x0,75
61x0,75
80x0,75
100x0,75
2x1
3x1
4x1
5x1
6x1
7x1
8x1
10x1
12x1
14x1
16x1
19x1
24x1
27x1
37x1
2x1,5
3x1,5
4x1,5
5x1,5
6x1,5
7x1,5
8x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5
27x1,5
37x1,5

Outer
Cop.
approx. mm weight
kg/km
10,6
129,0
10,7
152,0
11,2
156,0
11,7
173,0
12,6
236,0
12,7
250,0
12,7
265,0
14,1
297,0
14,6
301,0
15,3
312,0
15,3
320,0
15,3
325,0
15,8
345,0
18,1
407,0
19,1
508,0
21,9
690,0
24,3
814,0
3,8
19,0
5,8
38,0
6,3
50,0
6,8
57,0
7,3
70,0
8,1
87,0
8,2
96,0
9,0
110,0
10,3
140,0
10,5
151,0
11,3
167,0
11,8
183,0
12,6
207,0
12,6
221,0
13,4
238,0
14,1
270,0
14,3
278,0
14,3
287,0
15,8
315,0
16,3
330,0
17,1
350,0
17,1
370,0
17,9
386,0
17,9
395,0
18,4
408,0
21,5
555,0
24,6
715,0
27,2
910,0
6,4
46,0
6,7
56,0
7,2
69,0
8,0
89,0
8,6
105,0
8,6
111,0
9,4
130,0
11,2
140,0
11,4
168,0
12,0
198,0
12,8
218,0
13,6
268,0
15,2
320,0
15,4
360,0
18,3
485,0
7,3
63,0
7,6
76,0
8,3
98,0
9,2
116,0
9,9
140,0
9,9
152,0
10,8
172,0
13,0
193,0
13,0
254,0
13,9
272,0
14,9
285,0
15,6
387,0
17,7
448,0
17,9
506,0
21,2
682,0

Weight
approx.
kg/km
210,0
217,0
246,0
275,0
337,0
351,0
373,0
396,0
431,0
440,0
445,0
458,0
470,0
570,0
650,0
780,0
990,0
41,0
59,0
66,0
77,0
93,0
113,0
130,0
145,0
180,0
202,0
225,0
275,0
292,0
322,0
362,0
435,0
415,0
467,0
486,0
530,0
570,0
600,0
640,0
680,0
714,0
900,0
1200,0
1440,0
65,0
80,0
98,0
127,0
144,0
158,0
197,0
232,0
260,0
302,0
346,0
412,0
493,0
562,0
790,0
88,0
100,0
126,0
160,0
192,0
208,0
244,0
315,0
338,0
383,0
424,0
506,0
690,0
781,0
941,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

Dimensions and specifications may be changed without prior notice. (RB01)

B 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PAAR-TRONIC-CY

flexible, Cu-screened, colour coded to DIN 47100,

EMC-preferred type, meter marking




Technical data

Cable structure

Properties

Special PVC data cables, adapted to


DINVDE0812,0814
Temperature range
flexing -5 C to +80 C
fixed installation -30 C to +80 C
Operating voltage 350 V
(not for purposes of high current and
power installation)
Test voltage
core/core 1200 V
core/screen 800 V
Breakdown voltage min. 2400 V
Insulation resistance
min. 20 MOhm x km
Conductor resistance
at 0,14 mm 138 Ohm/km
at 0,25 mm 75,5 Ohm/km
at 0,34 mm 57,5 Ohm/km
at 0,50 mm 39 Ohm/km
at 0,75 mm 26 Ohm/km
Capacitance (approx.-value) at 800 Hz
core/core 0,14 mm = 120 pF/m
core/core 0,25 mm = 150 pF/m
core/screen 0,14 mm = 240 pF/m
core/screen 0,25 mm = 270 pF/m
Load
at 0,14 mm = 1,5 A
at 0,25 mm = 2,5 A
at 0,34 mm = 4,5 A
at 0,50 mm = 6 A
at 0,75 mm = 9 A
Inductance approx. 0,65 mH/km
Impedance approx. 78 Ohm
K1-coupling approx. 300 pF/100 m
Coupling resistance
max.250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, 0245 and
IEC60228 cl.5
Conductor make-up for
0,14mm = 18x0,1mm
0,25mm = 14x0,15mm
0,34mm = 7x0,25mm
Special PVC core insulation YI2, to
DINVDE0207 part4
Colours coded to DIN47100 with colour
repetition
Cores stranded in pairs with optimal
lay-length
Pairs stranded in layers with optimal
lay-length
Core wrapping with foil
Tinned copper braided screening, coverage
approx. 85%
Special PVC outer sheath YM2, to
DINVDE0207 part 5
Sheath colour grey (RAL7032)
with meter marking, change-over in 2011

Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

Also available in other sheath colours.


unscreened analogue type:
PAAR-TRONIC, see page B 6

Application
These data control cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist and wet
rooms but not suitable for open air.
PAAR-TRONIC-CY is well suited for use in areas subject to signal interference. The high level of screening reduces substantially the effects
of electrical disturbances from parallel running wiring etc. The copper screening is also often used as an "earth".
The twisted pairs conform favourable cross-talk attenuation values. These cables are suitable for dry and wet rooms, yet not for open air.
EMC = Electromagnetic compatibillity
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
21001
21002
21003
21004
21005

No.pairs x
cross-sec.
mm
1 x 2 x 0,14
2 x 2 x 0,14
3 x 2 x 0,14
4 x 2 x 0,14
5 x 2 x 0,14

Outer
Cop.
approx. mm weight
kg/km
4,1
15,6
5,6
18,5
5,6
23,0
6,0
26,6
6,7
30,7

Weight
approx.
kg/km
34,0
40,0
49,0
55,0
66,0

AWG-No.
26
26
26
26
26


Part no.
21006
21007
21008
21009
21010

No.pairs x
cross-sec.
mm
6 x 2 x 0,14
7 x 2 x 0,14
8 x 2 x 0,14
10 x 2 x 0,14
12 x 2 x 0,14

Outer
Cop.
approx. mm weight
kg/km
7,2
48,5
7,2
51,1
8,4
53,7
9,1
59,0
9,2
66,0

Weight
approx.
kg/km
86,0
91,0
97,0
109,0
141,0

AWG-No.
26
26
26
26
26

Continuation

B 11
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PAAR-TRONIC-CY

flexible, Cu-screened, colour coded to DIN 47100,

EMC-preferred type, meter marking

Part no.
21011
21012
21013
21014
21015
21016
21017
21018
21019
21020
21021
21022
21023
21024
21025
21026
21027
21028
21029
21030
21031
21032
21033
21034
21035
21036
21037
21038
21039
21040
21041
21042
21043
21044
21045
21046
21047
21048
21049
21050
21051
21052
21053
21054
21055
21056
21057
21058
21059
21060
21061
21062
21063
21064
19970
19971

No.pairs x
cross-sec.
mm
14 x 2 x 0,14
15 x 2 x 0,14
16 x 2 x 0,14
18 x 2 x 0,14
20 x 2 x 0,14
22 x 2 x 0,14
24 x 2 x 0,14
25 x 2 x 0,14
26 x 2 x 0,14
27 x 2 x 0,14
28 x 2 x 0,14
30 x 2 x 0,14
32 x 2 x 0,14
34 x 2 x 0,14
36 x 2 x 0,14
38 x 2 x 0,14
40 x 2 x 0,14
44 x 2 x 0,14
46 x 2 x 0,14
50 x 2 x 0,14
52 x 2 x 0,14
55 x 2 x 0,14
1 x 2 x 0,25
2 x 2 x 0,25
3 x 2 x 0,25
4 x 2 x 0,25
5 x 2 x 0,25
6 x 2 x 0,25
7 x 2 x 0,25
8 x 2 x 0,25
10 x 2 x 0,25
12 x 2 x 0,25
14 x 2 x 0,25
15 x 2 x 0,25
16 x 2 x 0,25
18 x 2 x 0,25
20 x 2 x 0,25
22 x 2 x 0,25
24 x 2 x 0,25
25 x 2 x 0,25
26 x 2 x 0,25
27 x 2 x 0,25
28 x 2 x 0,25
30 x 2 x 0,25
32 x 2 x 0,25
34 x 2 x 0,25
36 x 2 x 0,25
38 x 2 x 0,25
40 x 2 x 0,25
44 x 2 x 0,25
46 x 2 x 0,25
50 x 2 x 0,25
52 x 2 x 0,25
55 x 2 x 0,25
1 x 2 x 0,34
2 x 2 x 0,34

Outer
Cop.
approx. mm weight
kg/km
9,9
74,0
10,4
76,0
10,4
79,0
11,0
83,0
11,5
97,0
12,3
103,0
12,3
111,0
12,5
113,0
12,5
122,0
12,5
125,0
13,7
128,0
13,7
140,0
14,2
145,0
14,7
150,0
14,9
156,0
15,6
162,0
16,1
177,0
16,8
181,0
17,0
195,0
17,7
202,0
17,7
206,0
18,2
210,0
4,6
15,0
6,3
28,0
6,6
32,0
7,0
38,0
7,8
55,0
8,6
65,0
8,6
70,0
9,8
75,0
11,0
110,0
11,2
117,0
12,2
122,0
12,8
134,0
12,8
143,0
13,5
148,0
14,1
162,0
14,9
172,0
15,3
223,0
15,5
233,0
15,5
238,0
15,5
244,0
17,0
249,0
17,0
254,0
17,6
290,0
18,2
312,0
18,2
322,0
19,0
339,0
19,7
349,0
20,5
359,0
20,7
398,0
21,5
403,0
21,5
435,0
22,1
464,0
5,2
16,0
7,0
36,9

Weight
approx.
kg/km
148,0
152,0
155,0
171,0
183,0
205,0
228,0
239,0
245,0
251,0
258,0
270,0
284,0
300,0
316,0
350,0
370,0
390,0
430,0
440,0
460,0
480,0
45,0
53,0
65,0
80,0
98,0
114,0
121,0
129,0
157,0
189,0
213,0
225,0
237,0
248,0
275,0
303,0
330,0
343,0
345,0
350,0
360,0
375,0
400,0
410,0
420,0
450,0
485,0
500,0
540,0
550,0
580,0
630,0
58,0
65,0

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
22
22


Part no.
19972
19973
19974
19975
19976
19977
19978
19979
19980
19981
19982
19983
19984
19985
19986
19987
19988
19989
19990
19991
19992
19993
19994
19995
17047
17001
17002
17003
17004
17005
17006
17007
17008
17009
17010
17011
17048
17012
17013
17014
17015
17016
17017
17018
17019
17020
17021
17022
17049
17050
17051
17052
17053
17054
17055
17056

No.pairs x
cross-sec.
mm
3 x 2 x 0,34
4 x 2 x 0,34
5 x 2 x 0,34
6 x 2 x 0,34
7 x 2 x 0,34
8 x 2 x 0,34
9 x 2 x 0,34
10 x 2 x 0,34
12 x 2 x 0,34
14 x 2 x 0,34
16 x 2 x 0,34
18 x 2 x 0,34
21 x 2 x 0,34
25 x 2 x 0,34
27 x 2 x 0,34
30 x 2 x 0,34
34 x 2 x 0,34
37 x 2 x 0,34
40 x 2 x 0,34
44 x 2 x 0,34
50 x 2 x 0,34
52 x 2 x 0,34
56 x 2 x 0,34
61 x 2 x 0,34
1 x 2 x 0,5
2 x 2 x 0,5
3 x 2 x 0,5
4 x 2 x 0,5
5 x 2 x 0,5
6 x 2 x 0,5
8 x 2 x 0,5
10 x 2 x 0,5
12 x 2 x 0,5
16 x 2 x 0,5
20 x 2 x 0,5
25 x 2 x 0,5
1 x 2 x 0,75
2 x 2 x 0,75
3 x 2 x 0,75
4 x 2 x 0,75
5 x 2 x 0,75
6 x 2 x 0,75
8 x 2 x 0,75
10 x 2 x 0,75
12 x 2 x 0,75
16 x 2 x 0,75
20 x 2 x 0,75
25 x 2 x 0,75
1x2x1
2x2x1
3x2x1
4x2x1
1 x 2 x 1,5
2 x 2 x 1,5
3 x 2 x 1,5
4 x 2 x 1,5

Outer
Cop.
approx. mm weight
kg/km
7,3
44,9
8,1
54,2
8,8
63,5
9,8
73,1
9,8
79,5
11,2
88,4
12,6
99,3
12,6
106,9
12,8
122,1
13,3
138,2
14,3
154,2
15,2
197,9
15,9
214,4
17,5
238,5
17,5
262,5
19,1
286,6
20,8
310,1
21,5
368,7
22,4
392,6
23,6
424,3
24,8
455,9
24,8
487,6
25,4
518,5
26,2
557,2
5,6
24,0
7,8
54,0
8,2
70,0
9,1
91,0
9,9
105,0
10,7
120,0
12,8
144,0
14,0
178,0
14,3
199,0
16,1
254,0
17,2
302,0
19,7
344,0
6,0
28,0
8,4
58,0
8,9
84,0
9,8
108,0
10,8
126,0
12,1
146,0
13,4
180,0
15,5
220,0
15,8
261,0
18,0
328,0
19,2
392,0
21,8
470,0
6,3
46,0
8,9
82,0
9,4
103,0
10,4
132,0
7,2
63,0
10,2
111,0
10,8
136,0
12,0
172,0

Weight
approx.
kg/km
78,0
90,0
110,0
130,0
145,0
150,0
170,0
190,0
220,0
245,0
250,0
275,0
300,0
400,0
410,0
440,0
510,0
550,0
590,0
600,0
650,0
680,0
750,0
840,0
60,0
89,0
104,0
126,0
148,0
171,0
290,0
320,0
361,0
421,0
580,0
740,0
71,0
105,0
128,0
156,0
189,0
216,0
309,0
355,0
405,0
565,0
700,0
950,0
75,0
116,0
140,0
191,0
84,0
122,0
194,0
240,0

AWG-No.
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
20
20
20
20
20
20
20
20
20
20
20
20
19
19
19
19
19
19
19
19
19
19
19
19
18
18
18
18
16
16
16
16

Dimensions and specifications may be changed without prior notice. (RB01)

B 12
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PAAR-CY-OZ

flexible, Cu-screened, EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Special PVC data cables, screened, adapted


to DINVDE0812,0814
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage
core/core 1200 V
core/screen 800 V
Breakdown voltage min. 2400 V
Insulation resistance
min. 20 MOhm x km
Mutual capacitance according to
different cross-sections
0,5 mm2 to 1,5 mm:
core/core approx. 150 nF/km
core/screen approx. 270 nF/km
Inductance approx. 0,67 mH/km
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Special PVC core insulation TI2, to
DINVDE0281 part1
Black cores with continuous numbering in
white according to DINVDE0293
Cores laid up in pairs
Pairs stranded in layers with optimal
lay-length
Foil wrap
Tinned copper screened braiding,approx.
85% coverage
Special PVC outer sheath TM2, to
DINVDE0281 part1
Colour grey (RAL7032)
with meter marking, change-over in 2011

Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

x = without green-yellow earth core (OZ).


AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
We deliver other dimensions and other
colours of outer jackets on request.

Application
PAAR-CY is ideal for use as a connecting cable for all areas involving measuring, control, regulation and signal transfer as well as for use in
all fields of data and impulse transmission.
Especially suited for all areas of high electromagnetic activity, e. g. disturbances through parallel circuits.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
17023
17024
17025
17026
17027
17028
17029
17030
17031
17032
17033

No.pairs x
cross-sec.
mm
2x2x1
3x2x1
4x2x1
5x2x1
6x2x1
8x2x1
10 x 2 x 1
12 x 2 x 1
16 x 2 x 1
20 x 2 x 1
25 x 2 x 1

Outer
Cop.
approx. mm weight
kg/km
9,5
82,0
10,0
103,0
11,0
132,0
12,3
161,0
13,4
188,0
14,7
240,0
16,4
282,0
18,2
324,0
19,0
412,0
19,8
505,0
23,5
610,0

Weight
approx.
kg/km
135,0
160,0
197,0
253,0
295,0
410,0
518,0
601,0
990,0
1400,0
1600,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17


Part no.
17034
17035
17036
17037
17038
17039
17040
17041
17042
17043
17044

No.pairs x
cross-sec.
mm
2 x 2 x 1,5
3 x 2 x 1,5
4 x 2 x 1,5
5 x 2 x 1,5
6 x 2 x 1,5
8 x 2 x 1,5
10 x 2 x 1,5
12 x 2 x 1,5
16 x 2 x 1,5
20 x 2 x 1,5
25 x 2 x 1,5

Outer
Cop.
approx. mm weight
kg/km
11,3
112,0
12,2
139,0
13,5
176,0
14,5
212,0
17,2
255,0
18,2
322,0
20,1
380,0
21,8
442,0
25,0
572,0
27,0
705,0
29,5
862,0

Weight
approx.
kg/km
168,0
221,0
269,0
314,0
550,0
650,0
900,0
950,0
1100,0
1700,0
1900,0

AWG-No.
16
16
16
16
16
16
16
16
16
16
16

Dimensions and specifications may be changed without prior notice. (RB01)

B 13
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PAAR-TRONIC-CY-CY (LiYCY-CY)

EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Special PVC data transmission cable


adapted to DINVDE0812 and0814
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Conductor resistance
0,14 mm = max. 138 Ohm/km
0,25 mm = max. 77,8 Ohm/km
Nominal voltage
0,14 mm = max. 350 V
0,25 mm = max. 500 V
Test voltage
0,14 mm = 1200 V
0,25 mm = 2000 V
Breakdown voltage
0,14 mm = 2400 V
0,25 mm = 4000 V
Mutual capacitance
core/core
0,14 mm = 147 pF/m
0,25 mm = 152,5 pF/m
core/screen
0,14 mm = 147 pF/m
0,25 mm = 263 pF/m
Impedance
0,14 mm = 536 Ohm/1 kHz/20 C
0,25 mm = 396 Ohm/1 kHz/20 C
Coupling 250 pF/100 m/1 kHz
Screen resistance
0,14 mm = 36 Ohm/km
0,25 mm = 18 Ohm/km
Attenuation
0,14 mm = 3,6 dB/1 kHz/km
0,25 mm = 2,2 dB/1 kHz/km
Minimum bending radius
flexing 12x cable
fixed installation 6x cable
Radiation resistance
up to 80x106 cJ/kg (bis 80 Mrad)

Bare copper, fine wire conductors, to


DINVDE0812
Strand make-up
0,14 mm = 18x0,10 mm
0,25 mm =14x0,15 mm
0,34 mm = 7x0,25 mm
Special PVC core insulation YI2, to
DINVDE0207 part4
Core colours to DIN 47100 with colour
repetition
Cores stranded in pairs with optimal
lay-length
Pairs screened individually, tinned copper,
coverage approx. 85%
Special PVC coating over individual
screened pairs
All pairs-CY stranded together
Core wrapping with polyester foil,
overlapped
Overall braid-screening, tinned copper
coverage approx. 85%
Special PVC outer sheath YM2, to
DINVDE0207 part5
Colour grey (RAL7001)
with meter marking, change-over in 2011


Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

As of 0,75 mm cross-sec. see type


L-EDV-PiMF-CY.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
This cable type offers total interference-free data transfer and is ideal for use as a signal and control cable in combination with computers
and external units. The screening properties also make this cable type well suited for use as a connecting cable in sound studio equipment,
measuring and control sectors as well as proving a highly reliable cable for process-control and security systems.
The copper screening assures a disturbance-free data and signal transmission for measuring and control systems.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
21065
21066
21067
21068
21069
21070

No.pairs x
cross-sec.
mm
2 x 2 x 0,14
3 x 2 x 0,14
4 x 2 x 0,14
5 x 2 x 0,14
6 x 2 x 0,14
7 x 2 x 0,14

Outer
Cop.
approx. mm weight
kg/km
7,4
31,0
8,5
34,0
10,0
45,0
10,5
58,0
11,6
67,0
12,1
78,0

Weight
approx.
kg/km
95,0
105,0
140,0
160,0
185,0
230,0

AWG-No.
26
26
26
26
26
26


Part no.
21071
21072
21073
21074
21075
21076

No.pairs x
cross-sec.
mm
8 x 2 x 0,14
9 x 2 x 0,14
10 x 2 x 0,14
12 x 2 x 0,14
16 x 2 x 0,14
20 x 2 x 0,14

Outer
Cop.
approx. mm weight
kg/km
13,2
97,0
14,1
101,0
15,1
108,0
15,3
134,0
17,0
179,0
17,8
225,0

Weight
approx.
kg/km
245,0
280,0
325,0
380,0
440,0
520,0

AWG-No.
26
26
26
26
26
26

Continuation

B 14
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PAAR-TRONIC-CY-CY (LiYCY-CY)


Part no.
21077
21078
21079
21080
21081
21082
21083
21084
21085
21086
21087
21088
21089
21090
21091
21092
21093
21094
21095
21096
21097
21098
21099
21100

No.pairs x
cross-sec.
mm
2 x 2 x 0,25
3 x 2 x 0,25
4 x 2 x 0,25
5 x 2 x 0,25
6 x 2 x 0,25
7 x 2 x 0,25
8 x 2 x 0,25
10 x 2 x 0,25
12 x 2 x 0,25
16 x 2 x 0,25
20 x 2 x 0,25
24 x 2 x 0,25
32 x 2 x 0,25
48 x 2 x 0,25
2 x 2 x 0,34
3 x 2 x 0,34
4 x 2 x 0,34
6 x 2 x 0,34
8 x 2 x 0,34
10 x 2 x 0,34
12 x 2 x 0,34
14 x 2 x 0,34
16 x 2 x 0,34
24 x 2 x 0,34

Outer
Cop.
approx. mm weight
kg/km
8,1
62,0
9,5
78,2
10,5
124,1
11,9
137,6
12,6
148,1
13,9
159,1
14,2
178,7
15,2
213,9
17,5
238,3
22,0
291,4
22,6
325,0
27,5
367,5
29,8
588,0
34,5
840,5
9,5
73,1
11,6
88,1
12,4
137,2
15,0
174,8
16,5
247,2
19,0
288,7
19,5
321,0
20,7
388,4
22,5
425,5
28,0
577,1

Weight
approx.
kg/km
125,0
140,0
205,0
230,0
275,0
295,0
330,0
420,0
465,0
590,0
620,0
690,0
785,0
970,0
139,0
157,0
213,0
308,0
385,0
433,0
495,0
600,0
637,0
781,0

AWG-No.
24
24
24
24
24
24
24
24
24
24
24
24
24
24
22
22
22
22
22
22
22
22
22
22

EMC-preferred type, meter marking


Part no.
21101
21102
21103
21104
21105
21106
21107
21108
21109
21110

No.pairs x
cross-sec.
mm
2 x 2 x 0,5
3 x 2 x 0,5
4 x 2 x 0,5
6 x 2 x 0,5
8 x 2 x 0,5
10 x 2 x 0,5
12 x 2 x 0,5
14 x 2 x 0,5
16 x 2 x 0,5
24 x 2 x 0,5

Outer
Cop.
approx. mm weight
kg/km
10,4
83,1
11,6
106,4
13,0
158,0
15,6
201,4
18,0
311,5
20,8
334,5
21,5
394,1
21,6
446,0
23,8
501,2
28,4
712,4

Weight
approx.
kg/km
143,0
179,0
241,0
319,0
441,0
464,0
529,0
641,0
694,0
930,0

AWG-No.
20
20
20
20
20
20
20
20
20
20

Dimensions and specifications may be changed without prior notice. (RB01)

Insulating, shrinking, braided and


temperature protection tubes
Braided hoses
High temperature protection
Insulation tubes
Heat-shrink tubes
End caps

You can nd insulating, shrinking, braided and temperature protection tubes


in our catalogue Cable Accessories.

B 15
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PAAR-TRONIC-Li-2YCYv

PE-insulated, low capacitance, Termi-Point,

EMC-preferred type, meter marking




Technical data

Cable structure

Properties

PE-insulated data cable


Temperature range
flexing -5 C to +70 C
fixed installation -30 C to +80 C
Conductor resistance (loop) at 20 C
0,22 mm max. 186 Ohm/km
0,34 mm max. 115 Ohm/km
0,5 mm max. 78,5 Ohm/km
1,0 mm max. 39,2 Ohm/km
Operating top level voltage
max. 250 V (not for purposes of
high current and power installation)
Test voltage
core/core 2000 V
core/screen 1000 V
Insulation resistance min. 5 GOhm x km
Mutual capacitance at 800 Hz
>4 pairs max. 60 nF/km
4 pairs values extended by 20%
Impedance 100 Ohm 15
Line attenuation (approx. value)
0,22 mm at 100 kHz 9,0 dB/km
0,34 mm at 100 kHz 6,6 dB/km
0,50 mm at 100 kHz 6,0 dB/km
0,22 mm at 1 MHz 25,0 dB/km
0,34 mm at 1 MHz 20,0 dB/km
0,50 mm at 1 MHz 18,0 dB/km
Inductance approx. 0,66 mH/km
Cross-talk attenuation
up 1 MHz min. 50 dB
up 10 MHz min. 40 dB
Minimum bending radius
flexing 12x cable
fixed installation 7,5x cable

Bare copper stranded wires, 7-wires,


adapted to DINVDE0881, suitable for
Termi-Point and solder-free connection
technique
Conductor make-up
0,22 mm = 7x0,20 mm
0,34 mm = 7x0,25 mm
0,5 mm = 7x0,30 mm
Core insulation of PE, compound type2YI1
to DINVDE0207 part2
Core colours to DIN47100 with colour
repetition
Cores stranded in pairs with optimal
lay-length
Pairs stranded in layers with optimal
lay-length
Core wrapping with foil
Tinned copper braided screening, coverage
approx. 85%
Special PVC outer sheath YM2 black, to
DINVDE0207 part5
Type . . . Yv with reinforced outer sheath
with meter marking, change-over in 2011


PVC outher sheath self-extinguishing and


flame retardant according to VDE
0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
These cables make enormous advantages
possible for fast and cost-effective
contact-making using the Termi-Point
connection technique. With this solder-free
connection technique, the stranded
conductor is crimped together with a
sleeve onto a contact pin without prior
stripping of the insulation material
The twisted-pair lay-up prevents electrical
unbalances within the cable and this thus
effectively suppresses cross-talking effects
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

At 0,22 mm is designed for applications


with Sub-D connectors.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Thermi-Point registered trade mark AMP.
To optimise the EMC features we
recommend a large round contact of the
copper braiding on both ends.

Application
These PE-insulated data cables with twisted pairs are used in particular for the interference-free transmission of data and signals over longer
distances. The high transmission rates are particularly suitable for RS 422 and RS 485 interfaces. These cables are suitable for fixed installations
as well as for flexing applications, for free movement without forced motion and without tensile stress, in dry and moist environments. Yv
black with reinforced outer sheath, is suitable for installation in the ground and in open air. 
EMC = Electromagnetic compatibillity
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
21129
21130
21131
21132
21133
21135
21136
21137
21138
21139

No.pairs x
cross-sec.
mm
2 x 2 x 0,22
3 x 2 x 0,22
4 x 2 x 0,22
8 x 2 x 0,22
10 x 2 x 0,22
2 x 2 x 0,34
3 x 2 x 0,34
4 x 2 x 0,34
8 x 2 x 0,34
10 x 2 x 0,34

Outer
Cop.
approx. mm weight
kg/km
8,0
26,0
8,3
31,0
8,9
38,0
10,6
62,0
12,1
79,0
9,2
35,0
9,6
44,0
10,2
53,0
12,8
86,0
14,1
104,0

Weight
approx.
kg/km
60,0
79,0
96,0
140,0
184,0
83,0
92,0
112,0
179,0
219,0

AWG-No.
24
24
24
24
24
22
22
22
22
22


Part no.
21141
21142
21143
21144
21145
21146
21147
21148
21149
21150

No.pairs x
cross-sec.
mm
2 x 2 x 0,5
3 x 2 x 0,5
4 x 2 x 0,5
8 x 2 x 0,5
10 x 2 x 0,5
2x2x1
3x2x1
4x2x1
8x2x1
10 x 2 x 1

Outer
Cop.
approx. mm weight
kg/km
10,0
49,0
10,4
60,0
11,2
73,0
13,9
124,0
16,0
155,0
10,8
81,0
11,5
102,0
12,0
130,0
14,9
240,0
17,2
282,0

Weight
approx.
kg/km
90,0
126,0
146,0
246,0
292,0
141,0
170,0
203,0
261,0
287,0

AWG-No.
20
20
20
20
20
17
17
17
17
17

Dimensions and specifications may be changed without prior notice.

B 16
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PAAR-TRONIC-Li-2YCY

PE-insulated, low capacitance, Termi-Point,

EMC-preferred type, meter marking




Technical data

Cable structure

Properties

PE-insulated data cable


Temperature range
flexing -5 C to +70 C
fixed installation -30 C to +80 C
Conductor resistance (loop) at 20 C
0,22 mm max. 186 Ohm/km
0,34 mm max. 115 Ohm/km
0,5 mm max. 78,5 Ohm/km
Operating top level voltage
max. 250 V (not for purposes of
high current and power installation)
Test voltage
core/core 2000 V
core/screen 1000 V
Insulation resistance min. 5 GOhm x km
Mutual capacitance at 800 Hz
>4 pairs max. 60 nF/km
4 pairs values extended by 20%
Impedance 100 Ohm 15
Line attenuation (approx. value)
0,22 mm at 100 kHz 9,0 dB/km
0,34 mm at 100 kHz 6,6 dB/km
0,50 mm at 100 kHz 6,0 dB/km
0,22 mm at 1 MHz 25,0 dB/km
0,34 mm at 1 MHz 20,0 dB/km
0,50 mm at 1 MHz 18,0 dB/km
Inductance approx. 0,66 mH/km
Cross-talk attenuation
up 1 MHz min. 50 dB
up 10 MHz min. 40 dB
Minimum bending radius
flexing 12x cable
fixed installation 7,5x cable

Bare copper stranded wires, 7-wires,


adapted to DINVDE0881, suitable for
Termi-Point and solder-free connection
technique
Conductor make-up
0,22 mm = 7x0,20 mm
0,34 mm = 7x0,25 mm
0,5 mm = 7x0,30 mm
Core insulation of PE, compound type2YI1
to DINVDE0207 part2
Core colours to DIN47100 with colour
repetition
Cores stranded in pairs with optimal
lay-length
Pairs stranded in layers with optimal
lay-length
Core wrapping with foil
Tinned copper braided screening, coverage
approx. 85%
Special PVC outer sheath YM2 grey, to
DINVDE0207 part5
with meter marking, change-over in 2011


PVC outher sheath self-extinguishing and


flame retardant according to VDE
0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
These cables make enormous advantages
possible for fast and cost-effective
contact-making using the Termi-Point
connection technique. With this solder-free
connection technique, the stranded
conductor is crimped together with a
sleeve onto a contact pin without prior
stripping of the insulation material
The twisted-pair lay-up prevents electrical
unbalances within the cable and this thus
effectively suppresses cross-talking effects
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

At 0,22 mm is designed for applications


with Sub-D connectors.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Thermi-Point registered trade mark AMP.
To optimise the EMC features we
recommend a large round contact of the
copper braiding on both ends.

Application
These PE-insulated data cables with twisted pairs are used in particular for the interference-free transmission of data and signals over longer
distances. The high transmission rates are particularly suitable for RS 422 and RS 485 interfaces. These cables are suitable for fixed installations
as well as for flexing applications, for free movement without forced motion and without tensile stress, in dry and moist environments but
notin openair (Type grey).
EMC = Electromagnetic compatibillity
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
21111
21112
21113
21114
21115
21117
21118
21119
21120
21121
21123
21124
21125
21126
21127

No.pairs x
cross-sec.
mm
2 x 2 x 0,22
3 x 2 x 0,22
4 x 2 x 0,22
8 x 2 x 0,22
10 x 2 x 0,22
2 x 2 x 0,34
3 x 2 x 0,34
4 x 2 x 0,34
8 x 2 x 0,34
10 x 2 x 0,34
2 x 2 x 0,5
3 x 2 x 0,5
4 x 2 x 0,5
8 x 2 x 0,5
10 x 2 x 0,5

Outer
Cop.
approx. mm weight
kg/km
6,4
26,0
6,7
31,0
7,3
38,0
9,0
62,0
10,5
79,0
7,6
35,0
8,0
44,0
8,6
53,0
11,2
86,0
12,5
104,0
8,4
49,0
8,8
60,0
9,6
73,0
12,3
124,0
14,5
155,0

Weight
approx.
kg/km
48,0
66,0
82,0
123,0
165,0
68,0
77,0
95,0
158,0
195,0
74,0
109,0
128,0
223,0
265,0

AWG-No.
24
24
24
24
24
22
22
22
22
22
20
20
20
20
20

Dimensions and specifications may be changed without prior notice. (RB01)

B 17
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LifYCY

high flexible, paired, screened, EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Special PVC connecting cable, adapted to


DINVDE0812,0814
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage 350 V
Test voltage 1200 V
Breakdown voltage min. 2400 V
Insulation resistance
min. 10 MOhm x km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, extra fine


conductors(102x0,05 = 0,2 mm)
Special PVC core insulation YI2, to
DINVDE0207part4
Core identification to DIN47100
Cores twisted in pairs, pairs twisted in layers
Core wrapping with polyester tape
Tinned copper, screened braiding, approx.
85% coverage
Special PVC outer sheath YM2, to
DINVDE0207part5
Colour grey (RAL 7032)
with meter marking, change-over in 2011

Extensively oil resistant, oil-/chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application
These screened cables are used as connecting cable for signal, measuring, control and speaking purposes for example in Intercom systems,
weighing instruments, equipment for office works, computers and telecommunication equipment etc. The cable offers a flexible handling
and installation. Due to pair-twisting, the electrical unbalances of the cable itself can be reduced and cross-talk effects are avoided.
The tinned copper screened braiding serves as protection against outer high frequency influences (capacitance unbalance). The drain wire
ensure an exact connection to the earth clamp.
The cables are suitable for fixed installation and flexible application, free-moving without tensile stress and without forced guiding operation
in dry, damp and wet places for medium mechanical stress.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
15987
15988
15989
15990
15991
15992
15993

No.pairs x
cross-sec.
mm
2 x 2 x 0,2
3 x 2 x 0,2
4 x 2 x 0,2
5 x 2 x 0,2
6 x 2 x 0,2
7 x 2 x 0,2
8 x 2 x 0,2

Outer
Cop.
approx. mm weight
kg/km
5,9
24,0
6,1
35,0
6,6
45,0
7,9
54,0
8,6
56,0
8,9
68,0
9,4
72,0

Weight
approx.
kg/km
60,0
70,0
80,0
90,0
100,0
120,0
130,0

AWG-No.


Part no.

15994
15995
15996
15997
15998
15999
16000

No.pairs x
cross-sec.
mm
10 x 2 x 0,2
12 x 2 x 0,2
16 x 2 x 0,2
18 x 2 x 0,2
20 x 2 x 0,2
24 x 2 x 0,2
32 x 2 x 0,2

Outer
Cop.
approx. mm weight
kg/km
9,9
108,0
10,9
125,0
12,5
144,0
13,1
155,0
13,9
216,0
13,2
228,0
16,6
269,0

Weight
approx.
kg/km
150,0
180,0
210,0
230,0
250,0
330,0
400,0

AWG-No.
-

Dimensions and specifications may be changed without prior notice. (RB01)

B 18
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRONIC 1-CY

each core individually screened, EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Special PVC core insulation, adapted to


DINVDE0812
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage
0,25 mm 250 V
0,50 mm 350 V
Test voltage (core/screen)
0,25 mm 800 V
0,50 mm 1200 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360cl.5 (for
0,5mm)0,25mm to DINVDE0812
Strand make-up
0,25mm 14x0,15mm
0,50mm 16x0,20mm
Special PVC core insulation YI2, to
DINVDE0207part4
Colour coded to DIN47100
Each core individually copper spirally
screened, approx. 85% coverage
Cores stranded in layers with optimal
lay-length
Special PVC outer sheath YM2, to
DINVDE0207part5
Colour grey (RAL 7001)
with meter marking, change-over in 2011

Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application
The individually screened, flexible cable is ideal for use in data and impulse transfer in computers, communication systems and external
units and offers interference-free data flow for all measuring and command functions. This cable type is widely used in the machine and
steel producing industries as well as for traffic signals and data processing areas.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
49501
49502
49503
49504
49505
49506
49507
49508
49509
49510
49511

No.cores x
cross-sec.
mm
3x0,25
4x0,25
5x0,25
7x0,25
8x0,25
10x0,25
12x0,25
16x0,25
24x0,25
32x0,25
48x0,25

Outer
Cop.
approx. mm weight
kg/km
6,5
18,0
7,2
24,0
8,0
30,0
8,8
42,0
10,0
48,0
11,3
60,0
12,0
72,0
13,1
96,0
16,0
144,0
18,5
192,0
23,5
288,0

Weight
approx.
kg/km
40,0
45,0
56,0
70,0
87,0
90,0
95,0
115,0
170,0
210,0
320,0

AWG-No.
24
24
24
24
24
24
24
24
24
24
24


Part no.
49512
49513
49514
49515
49516
49517
49518
49519
49520

No.cores x
cross-sec.
mm
3x0,5
4x0,5
5x0,5
7x0,5
8x0,5
10x0,5
12x0,5
16x0,5
32x0,5

Outer
Cop.
approx. mm weight
kg/km
7,3
28,8
8,2
38,5
9,2
48,0
10,0
67,0
11,0
77,0
13,2
96,0
14,0
114,6
15,5
154,0
21,5
308,0

Weight
approx.
kg/km
71,0
81,0
95,0
115,0
145,0
169,0
185,0
225,0
440,0

AWG-No.
20
20
20
20
20
20
20
20
20

Dimensions and specifications may be changed without prior notice. (RB01)

B 19
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRONIC 2-CY

2 cores screened, meter marking

Technical data

Cable structure

Properties

Special PVC core insulation adapted to


DINVDE0812
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Conductor resistance
0,14 mm = max. 138 Ohm/km
0,25 mm = max. 77,8 Ohm/km
0,50 mm = max. 37,8 Ohm/km
Nominal voltage (50 Hz)
0,14 mm = max. 350 V
0,25 mm = max. 500 V
0,50 mm = max. 500 V
Test voltage (50 Hz eff)
0,14 mm = 800 V
0,25 mm = 800 V
0,50 mm = 1200 V
Breakdown voltage
0,14 mm = 1600 V
0,25 mm = 1600 V
0,50 mm = 2400 V
Insulation resistance
min. 200 MOhm x km
Mutual capacitance (approx.-value)
core/core
0,14 mm = 70 pF/m
0,25 mm = 80 pF/m
0,50 mm = 80 pF/m
core/screen
0,14 mm = 270 pF/m
0,25 mm = 350 pF/m
0,50 mm = 400 pF/m
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (bis 80 Mrad)


Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 (for 0,5mm) 0,14and0,25mm to
DINVDE0812
Strand make-up
0,14mm 18x0,10mm
0,25mm 14x0,15mm
0,50mm 16x0,20mm
Special PVC core insulation YI2, to
DINVDE0207 part4
White and brown cores each individually
screened
Colour coded to DIN47100
Cores stranded in layers with optimal
lay-length
Copper screened braiding, approx. 85%
coverage
Special PVC outer sheath YM2, to
DINVDE0207 part5
Colour grey (RAL7001)
with meter marking, change-over in 2011

Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application
TRONIC 2-CY is used in all areas of measuring and control technology requiring only 2 impulse transfer cores. This cable type is used mainly
in the machinery and industrial equipment fields as well as in the steel industry and in electronics.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
49521
49522
49523
49524
49525
49526
49527
49528
49529
49530

No.cores x
cross-sec.
mm
4x0,14
8x0,14
12x0,14
16x0,14
24x0,14
4x0,25
8x0,25
12x0,25
16x0,25
24x0,25

Outer
Cop.
approx. mm weight
kg/km
6,2
14,6
7,2
20,3
8,4
26,8
8,6
32,0
9,0
43,4
6,5
21,3
8,0
31,0
9,2
40,5
9,6
50,1
12,0
69,3

Weight
approx.
kg/km
40,0
50,0
70,0
80,0
110,0
60,0
90,0
120,0
140,0
200,0

AWG-No.
26
26
26
26
26
24
24
24
24
24


Part no.
49531
49532
49533
49534
49535

No.cores x
cross-sec.
mm
4x0,5
8x0,5
12x0,5
16x0,5
24x0,5

Outer
Cop.
approx. mm weight
kg/km
7,6
34,0
11,6
53,2
11,9
72,4
12,5
91,6
15,3
130,0

Weight
approx.
kg/km
100,0
150,0
190,0
240,0
310,0

AWG-No.
20
20
20
20
20

Dimensions and specifications may be changed without prior notice. (RB01)

B 20
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LiY-TPC-Y

pairs screened, EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Pair screened special PVC data transmission


cable adapted to DINVDE0812 and0814
Temperature range
flexing -5 C to +70 C
fixed installation -30 C to +70 C
Operating top level voltage
500 V (not for purposes of
high current and power installation)
Test voltage 1200 V
Breakdown voltage min. 2400 V
Insulation resistance
min. 20 MOhm x km
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC228 cl.5 (for 0,5 mm)
0,25 and 0,34 mm to DINVDE0812
Strand make up
0,25 mm = 14x0,15 mm
0,34 mm = 7x0,25 mm
Special PVC core insulation YI2, to
DINVDE0207 part4
Core colours to DIN 47100
Cores stranded in pairs with optimal
lay-length
Each pair with foil wrapping
Pairs individually screened, tinned copper
coverage approx. 85%
All pairs-C stranded in layers with optimal
lay-length
Foil seperator Special PVC outer sheath
YM2, to DINVDE0207 part5
Colour grey (RAL7032)
with meter marking, change-over in 2011

Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application
This pair screened table type offers total interference-free data transfer and is ideal for use as a signal and control cable in combination with
computers and external units. The screening properties also make this cable type well suited for use as a connecting cable in sound studio
equipment, measuring and control sectors as well as proving a highly reliable cable for process-control and security systems.
The copper screening assures a disturbance-free data and signal transmission for measuring and control systems.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
21323
21324
21325
21326
21327
21328
21329
21340
21341
21342
21343
21344
21345

No.pairs x
cross-sec.
mm
2 x 2 x 0,25
3 x 2 x 0,25
4 x 2 x 0,25
5 x 2 x 0,25
6 x 2 x 0,25
7 x 2 x 0,25
10 x 2 x 0,25
2 x 2 x 0,34
3 x 2 x 0,34
4 x 2 x 0,34
5 x 2 x 0,34
7 x 2 x 0,34
10 x 2 x 0,34

Outer
Cop.
approx. mm weight
kg/km
6,2
32,0
6,8
48,0
8,1
64,0
9,1
80,0
9,0
96,0
9,6
112,0
11,7
160,0
7,1
42,0
7,9
63,0
9,6
84,0
10,6
105,0
11,3
147,0
13,4
210,0

Weight
approx.
kg/km
60,0
80,0
112,0
142,0
159,0
177,0
250,0
78,0
104,0
153,0
189,0
238,0
322,0

AWG-No.
24
24
24
24
24
24
24
22
22
22
22
22
22


Part no.
21355
21356
21357
21370
21371
21372
21373
21385
21386
21387

No.pairs x
cross-sec.
mm
2 x 2 x 0,5
3 x 2 x 0,5
4 x 2 x 0,5
2 x 2 x 0,75
3 x 2 x 0,75
4 x 2 x 0,75
5 x 2 x 0,75
2x2x1
3x2x1
4x2x1

Outer
Cop.
approx. mm weight
kg/km
8,3
58,0
8,8
87,0
10,2
116,0
8,9
76,0
9,8
114,0
11,2
152,0
12,7
190,0
9,3
86,0
10,1
130,0
11,9
149,0

Weight
approx.
kg/km
96,0
136,0
187,0
132,0
178,0
243,0
312,0
142,0
189,0
275,0

AWG-No.
20
20
20
18
18
18
18
17
17
17

Dimensions and specifications may be changed without prior notice. (RB01)

B 21
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

DATAPUR-C EMC-preferred type, Cu-screened, PUR-outer jacket, meter marking




Technical data

Cable structure

Properties

Special PVC/PUR control cable, adapted to


DINVDE0281
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Operating top level voltage
(not for purposes of high current and
power installation)
0,14 mm 350 V
as of 0,25 mm 500 V
Test voltage
0,14 mm 800 V
as of 0,25 mm 1200 V
Insulation resistance
min. 20 MOhm x km
Mutual capacitance core/core:
up to 0,34 mm approx. 120 nF/km
as of 0,5 mm approx. 160 nF/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
structure of conductors bei 0,35 mm =
7x0,25 mm
Special PVC core insulation TI2, to
DINVDE0281 part1
Cores colour coded to DIN47100
Cores stranded in layers with optimal
lay-length
Foil taped
Tinned copper braided screen, approx. 85%
coverage
PUR outer sheath TMPU to DINVDE0282
part1, appendixA
Sheath colour grey (RAL 7032)
with meter marking, change-over in 2011

Chemical resistance: good against acids,


lyes, hydraulic liquids
High flexibility at low temperature
High abrasion resistance

Resistant to
Oils and fats
Non-alcoholic fuels and kerosene
Atmospheric influences
UV-radiation
Oxygene and ozone
Microbes and rotting
Sea and waste water
Vibrations
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application
The specific construction of DATAPUR-C makes this cable type ideal for use in all types of computer systems, office machinery, signal and
control units.
DATAPUR-C has uses that go beyond this for example in the field of acustics, e.g. in telephone systems, intercoms as well as in all areas
involving accurate control of weights and measurements. This cable type is noted for its excellent mechanical performance in humid to wet
conditions. External high frequency interference is screened out by the tinned copper braiding. These cables are extremely tear and abrasive
resistant.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
52490
52491
52492
52493
52494
52495
52496
52497
52498
52499
52500
52501
52502
52503
52504
52505
52506
52507
52508
52509
52510
52511

No.cores x
cross-sec.
mm
2x0,14
3x0,14
4x0,14
5x0,14
7x0,14
10x0,14
12x0,14
14x0,14
18x0,14
21x0,14
25x0,14
2x0,25
3x0,25
4x0,25
5x0,25
7x0,25
10x0,25
12x0,25
14x0,25
18x0,25
21x0,25
25x0,25

Outer
Cop.
approx. mm weight
kg/km
4,0
12,3
4,1
14,0
4,4
15,7
4,8
19,5
5,1
23,4
6,2
28,5
6,5
34,3
6,8
39,9
7,7
51,5
8,0
60,1
8,8
71,9
4,5
14,7
4,7
17,1
5,0
20,6
5,4
24,8
5,8
31,1
7,2
42,0
7,7
51,0
8,1
60,1
9,0
77,9
9,6
91,4
10,7
110,8

Weight
approx.
kg/km
21,0
25,0
29,0
35,0
41,0
54,0
64,0
74,0
93,0
108,0
128,0
26,0
33,0
38,0
44,0
53,0
79,0
92,0
105,0
128,0
148,0
175,0

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
24
24
24
24
24
24
24
24
24
24
24


Part no.
52512
52513
52514
52515
52516
52517
52518
52519
52520
52521
52522
52523
52524
52525
52526
52527
52528
52529
52530
52531
52532
52533

No.cores x
cross-sec.
mm
2x0,34
3x0,34
4x0,34
5x0,34
7x0,34
10x0,34
12x0,34
14x0,34
18x0,34
21x0,34
25x0,34
2x0,5
3x0,5
4x0,5
5x0,5
7x0,5
10x0,5
12x0,5
14x0,5
18x0,5
21x0,5
25x0,5

Outer
Cop.
approx. mm weight
kg/km
5,0
17,0
5,2
20,7
5,6
24,7
6,2
30,1
6,7
38,2
8,4
63,1
8,9
74,2
9,3
85,3
10,2
107,4
10,9
124,1
11,9
147,0
5,4
23,2
5,6
30,1
6,2
35,4
6,7
52,6
7,2
65,3
9,3
88,8
9,7
101,9
10,2
115,1
11,4
141,2
11,9
161,1
13,1
187,9

Weight
approx.
kg/km
33,0
42,0
48,0
57,0
77,0
111,0
128,0
144,0
175,0
200,0
233,0
38,0
51,0
58,0
77,0
93,0
134,0
155,0
175,0
214,0
245,0
285,0

AWG-No.
22
22
22
22
22
22
22
22
22
22
22
20
20
20
20
20
20
20
20
20
20
20

Dimensions and specifications may be changed without prior notice. (RB01)

B 22
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

DATAFLAMM-C

EMC-preferred type, halogen-free, screened, meter marking

Technical data

Cable structure

Properties

Special data cable


Temperature range
flexing +5 C to +70 C
fixed installation -40 C to +70 C
Operating top level voltage
(not for purposes of high current and
power installation)
0,14 mm = 350 V
>0,14 mm = 500 V
Test voltage
0,14 mm = 800 V
>0,14 mm = 1200 V
Insulation resistance
min. 2 GOhm x km
Capacitance
core/core <70 nF/km
Minimum bending radius
approx. 7,5x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors to


DINVDE0812, conductor make-up for
0,34mm - 7x0,25mm
PE-insulation, compound type 2YJ1 to
DINVDE0207 part2
Cores colour coded to DIN47100
Cores twisted in layers with optimal
lay-length
Core wrapping with polyester (PETP) foil
Tinned copper screened braiding, approx.
85% coverage
Halogen-free outer sheath, to
DINVDE0207 part24, compound type HM2
Sheath colour grey (RAL 7005)
with meter marking, change-over in 2011

Halogen-free according to VDE0482


part267/ DINEN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Halogen-free sheath compound,
self-extinguishing and flame retardant
according to VDE0482 part265-2-1/
DINEN50265-2-1/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
PE-insulated cores, compared with the
conventional PVC-insulated cores, assure
a remarkable and more favourable
capacitance values
The halogen-free thermoplastic sheath
produce neither corrosive nor toxic gases


Note

unscreened analogue type:


DATAFLAMM see page B 8

Application
Are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations,
electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and
wet environments as well as in masonry and concrete. These cables are generally installed in telecommunication apparatus and data
transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame
propagation must be avoided. With screened braiding offers interference-free signal transfer.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
52365
52366
52367
52368
52369
52370
52371
52372
52373
52374
52375
52376
52377
52378
52379
52380
52381
52382
52384
52385
52386
52387
52388
52389
52390
52391
52392
52393
52394
52395
52396
52397

No.cores x
cross-sec.
mm
2x0,14
3x0,14
4x0,14
5x0,14
7x0,14
10x0,14
12x0,14
14x0,14
16x0,14
18x0,14
21x0,14
25x0,14
30x0,14
34x0,14
40x0,14
2x0,25
3x0,25
4x0,25
5x0,25
7x0,25
10x0,25
12x0,25
14x0,25
16x0,25
18x0,25
21x0,25
25x0,25
30x0,25
34x0,25
40x0,25
2x0,34
3x0,34

Outer
Cop.
approx. mm weight
kg/km
3,7
12,4
3,9
14,0
4,1
15,8
4,4
19,5
4,7
23,4
5,9
28,4
6,0
31,4
6,4
37,5
6,7
43,4
7,0
51,4
7,8
61,8
8,4
76,0
8,6
92,7
9,4
121,0
10,2
126,1
4,2
14,6
4,4
17,0
4,7
20,6
5,1
24,7
5,6
31,2
7,1
42,1
7,3
47,5
7,7
52,7
8,1
58,1
8,9
78,0
9,2
94,3
10,3
116,5
10,8
132,2
11,6
144,6
12,5
163,3
4,8
16,9
5,1
20,6

Weight
approx.
kg/km
21,0
25,0
26,0
32,0
39,0
54,0
69,0
76,0
82,0
90,0
102,0
121,0
146,0
167,0
170,0
23,0
28,0
34,0
42,0
49,0
81,0
88,0
100,0
113,0
126,0
144,0
164,0
191,0
214,0
245,0
31,0
38,0

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
22
22


Part no.
52398
52399
52400
52401
52402
52403
52404
52405
52406
52407
52408
52409
52410
52411
52412
52413
52414
52415
52416
52417
52418
52419
52420
52421
52422
52423
52424
52425
52426
52427
52428
52429

No.cores x
cross-sec.
mm
4x0,34
5x0,34
7x0,34
10x0,34
12x0,34
14x0,34
16x0,34
18x0,34
21x0,34
25x0,34
30x0,34
34x0,34
40x0,34
2x0,5
3x0,5
4x0,5
5x0,5
7x0,5
10x0,5
12x0,5
18x0,5
21x0,5
25x0,5
30x0,5
40x0,5
2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
10x0,75
12x0,75

Outer
Cop.
approx. mm weight
kg/km
5,5
24,5
6,0
30,0
6,5
38,2
8,4
62,2
8,7
69,4
9,0
82,1
9,7
95,0
10,4
107,3
10,8
122,4
12,4
142,2
12,9
162,6
13,8
178,9
15,1
203,3
5,1
23,0
5,5
30,0
5,9
35,3
6,6
52,5
7,1
65,3
9,3
88,7
9,4
98,7
11,1
141,2
12,3
161,0
13,4
187,2
14,1
223,2
16,4
294,9
5,9
30,6
6,2
38,1
6,9
58,0
7,5
68,4
8,1
88,4
10,6
122,5
10,9
137,2

Weight
approx.
kg/km
47,0
58,0
76,0
110,0
123,0
140,0
157,0
172,0
195,0
226,0
261,0
285,0
330,0
37,0
46,0
57,0
77,0
92,0
135,0
148,0
210,0
242,0
285,0
340,0
445,0
45,0
60,0
80,0
97,0
127,0
175,0
196,0

AWG-No.
22
22
22
22
22
22
22
22
22
22
22
22
22
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18

Dimensions and specifications may be changed without prior notice. (RB01)

B 23
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

DATAFLAMM-C-PAAR

EMC-preferred type, halogen-free, screened, meter

marking


Technical data

Cable structure

Properties

Special data cable


Temperature range
flexing +5 C to +70 C
fixed installation -40 C to +70 C
Operating top level voltage
(not for purposes of highcurrent and
power installation)
0,14 mm = 350 V
>0,14 mm = 500 V
Test voltage
0,14 mm = 800 V
>0,14 mm = 1200 V
Insulation resistance
min. 2 GOhm x km
Capacitance
core/core <70 nF/km
Minimum bending radius
approx. 7,5x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors to


DINVDE0812, conductor make-up for
0,34mm - 7x0,25mm
PE-insulation, compound type 2YJ1 to
DINVDE0207 part2
Cores colour coded to DIN47100
Cores twisted in layers
Core wrapping with polyester (PETP) foil
Tinned copper screened braiding, approx.
85% coverage
Halogen-free outer sheath, to
DINVDE0207 part24, compound type HM2
Sheath colour grey (RAL 7005)
with meter marking, change-over in 2011

Halogen-free according to VDE0482


part267/ DINEN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Halogen-free sheath compound,
self-extinguishing and flame retardant
according to VDE0482 part265-2-1/
DINEN50265-2-1/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application
Are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations,
electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and
wet environments as well as in masonry and concrete. PE-insulated cores, compared with the conventional PVC-insulated cores, assure a
remarkable and more favourable capacitance values. These cables are generally installed in telecommunication apparatus and data transmission
systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must
be avoided. With screened braiding offers interference-free signal transfer. The halogen-free thermoplastic sheath produce neither corrosive
nor toxic gases.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
52435
52436
52437
52438
52439
52440
52441
52442
52443
52444
52445
52446
52447
52448
52449
52450
52451
52452
52453
52454
52455
52456
52457
52458
52459

No.pairs x
cross-sec.
mm
2 x 2 x 0,14
3 x 2 x 0,14
4 x 2 x 0,14
5 x 2 x 0,14
6 x 2 x 0,14
7 x 2 x 0,14
10 x 2 x 0,14
12 x 2 x 0,14
15 x 2 x 0,14
18 x 2 x 0,14
2 x 2 x 0,25
3 x 2 x 0,25
4 x 2 x 0,25
5 x 2 x 0,25
6 x 2 x 0,25
7 x 2 x 0,25
10 x 2 x 0,25
12 x 2 x 0,25
15 x 2 x 0,25
18 x 2 x 0,25
2 x 2 x 0,34
3 x 2 x 0,34
4 x 2 x 0,34
5 x 2 x 0,34
6 x 2 x 0,34

Outer
Cop.
approx. mm weight
kg/km
5,1
22,5
6,1
25,6
6,3
39,1
7,4
45,3
8,0
51,4
8,2
54,2
8,6
68,7
9,6
78,3
10,0
79,9
10,4
99,2
5,8
27,1
7,0
42,4
7,6
54,5
8,3
59,8
9,2
64,6
9,4
71,3
10,7
93,3
11,2
108,0
11,7
123,4
12,9
139,7
6,8
43,3
7,7
55,0
8,4
64,0
9,4
74,5
10,1
85,0

Weight
approx.
kg/km
37,0
47,0
66,0
76,0
87,0
94,0
119,0
135,0
157,0
190,0
44,0
66,0
81,0
98,0
116,0
120,0
153,0
175,0
213,0
248,0
68,0
92,0
110,0
128,0
147,0

AWG-No.
26
26
26
26
26
26
26
26
26
26
24
24
24
24
24
24
24
24
24
24
22
22
22
22
22


Part no.
52460
52461
52462
52463
52464
52465
52466
52467
52468
52469
52470
52471
52472
52473
52474
52475
52476
52477
52478
52479
52480
52481
52482
52483
52484

No.pairs x
cross-sec.
mm
7 x 2 x 0,34
10 x 2 x 0,34
12 x 2 x 0,34
15 x 2 x 0,34
18 x 2 x 0,34
2 x 2 x 0,5
3 x 2 x 0,5
4 x 2 x 0,5
5 x 2 x 0,5
6 x 2 x 0,5
7 x 2 x 0,5
10 x 2 x 0,5
12 x 2 x 0,5
15 x 2 x 0,5
18 x 2 x 0,5
2 x 2 x 0,75
3 x 2 x 0,75
4 x 2 x 0,75
5 x 2 x 0,75
6 x 2 x 0,75
7 x 2 x 0,75
10 x 2 x 0,75
12 x 2 x 0,75
15 x 2 x 0,75
18 x 2 x 0,75

Outer
Cop.
approx. mm weight
kg/km
10,4
89,8
11,5
119,8
12,6
139,4
14,3
160,0
15,5
207,2
7,6
50,2
9,1
64,5
9,8
77,2
11,0
96,2
11,5
107,4
11,8
117,3
13,4
158,2
14,8
177,8
16,1
236,4
17,4
265,4
9,0
64,6
10,2
81,7
11,2
107,6
12,2
126,1
13,1
138,6
13,5
153,7
15,0
220,0
17,0
265,5
18,3
327,6
19,6
374,6

Weight
approx.
kg/km
154,0
209,0
245,0
279,0
363,0
76,0
107,0
134,0
150,0
176,0
185,0
275,0
330,0
380,0
450,0
105,0
137,0
166,0
200,0
236,0
255,0
363,0
434,0
500,0
580,0

AWG-No.
22
22
22
22
22
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18

Dimensions and specifications may be changed without prior notice. (RB01)

B 24
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

EDV-PiMF-CY

PE-insulated, low capacitance, EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Special PE data cable for computer


application
Temperature range
flexing -5 C to +80 C
fixed installation -20 C to +80 C
Operating top level voltage
max. 300 V
(not for purposes of high currentand
power installation)
Test voltage
core/core 2000 V
core/screen 1000 V
Insulation resistance
approx. 5 GOhm x km
Mutual capacitance
core/core approx. 75pF/m
Inductance approx. 0,4 mH/km
Cross-talk attenuation
min. 60 dB at 100 kHz
Impedance (approx. value)
at 1 kHz approx. 360 Ohm
at 10 kHz approx. 125 Ohm
at 100 kHz approx. 87 Ohm
at 1000 kHz approx. 70 Ohm
Line attenuation (approx. value)
at 1 kHz approx. 1,1 dB
at 10 kHz approx. 2,7 dB
at 100 kHz approx. 6,8 dB
at 1000 kHz approx. 35 dB
Minimum bending radius
flexing 10x cable
fixed installation 6x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors,


according to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
PE core insulation
Colour code as per DIN47100
PiMF: (pair in metal foil)
cores twisted in pairs; foil wrapped, plastic
coated aluminium foil and copper
drain-wire tinned, 100%coverage
PiMFs are stranded in layer
Core wrapping with plastic tapes
Overall copper screened braiding,
85%coverage
Outer jacket, TM2 in adapted to VDE0281
part1
Colour grey (RAL7032)
with meter marking, change-over in 2011

PVC outer sheath self-extinguishing and


flame retardant according to VDE
0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application
Absolute disturbance-free data transfer both for installed terminals in all areas of medicine and data technology. Also suitable for use in
machine tool and steel producing industries, traffic signal systems, assembly lines and food processing.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
43553
43554
43524
43555
43525
43526
43527
43528
43529
43530
43531
43532
43556
43557
43533
43558
43534
43535
43536
43537
43538

No.pairs x
cross-sec.
mm
2 x 2 x 0,5
3 x 2 x 0,5
4 x 2 x 0,5
5 x 2 x 0,5
6 x 2 x 0,5
8 x 2 x 0,5
10 x 2 x 0,5
16 x 2 x 0,5
20 x 2 x 0,5
30 x 2 x 0,5
40 x 2 x 0,5
50 x 2 x 0,5
2 x 2 x 0,75
3 x 2 x 0,75
4 x 2 x 0,75
5 x 2 x 0,75
6 x 2 x 0,75
8 x 2 x 0,75
10 x 2 x 0,75
16 x 2 x 0,75
20 x 2 x 0,75

Outer
Cop.
approx. mm weight
kg/km
9,5
50,0
10,0
66,0
11,0
108,0
11,5
120,0
13,2
148,0
13,9
180,0
15,5
236,0
21,2
338,0
22,9
394,0
27,9
577,0
38,3
684,0
43,2
834,0
10,6
61,0
11,7
97,0
13,5
141,0
13,6
163,0
15,5
198,0
16,4
246,0
19,8
305,0
22,7
446,0
23,9
530,0

Weight
approx.
kg/km
101,0
120,0
196,0
201,0
260,0
310,0
398,0
515,0
688,0
980,0
1390,0
1860,0
117,0
142,0
240,0
304,0
352,0
415,0
505,0
732,0
860,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18


Part no.
43539
43559
43560
43540
43561
43541
43542
43543
43544
43545
43546
43562
43563
43547
43564
43548
43549
43550
43551
43552

No.pairs x
cross-sec.
mm
30 x 2 x 0,75
2x2x1
3x2x1
4x2x1
5x2x1
6x2x1
8x2x1
10 x 2 x 1
16 x 2 x 1
20 x 2 x 1
30 x 2 x 1
2 x 2 x 1,5
3 x 2 x 1,5
4 x 2 x 1,5
5 x 2 x 1,5
6 x 2 x 1,5
8 x 2 x 1,5
10 x 2 x 1,5
16 x 2 x 1,5
20 x 2 x 1,5

Outer
Cop.
approx. mm weight
kg/km
30,9
765,0
12,0
72,0
12,3
104,0
14,4
186,0
17,4
231,0
17,1
260,0
19,2
322,0
19,8
382,0
23,5
578,0
29,4
710,0
35,4
1050,0
14,0
81,0
14,7
141,0
16,1
261,0
18,4
284,0
19,5
355,0
20,7
448,0
23,9
551,0
29,7
838,0
31,7
1030,0

Weight
approx.
kg/km
1210,0
130,0
161,0
360,0
412,0
472,0
540,0
670,0
982,0
1240,0
1720,0
164,0
197,0
480,0
516,0
590,0
696,0
874,0
1340,0
1620,0

AWG-No.
18
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16

Dimensions and specifications may be changed without prior notice. (RB01)

B 25
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

RD-Y(St)Y

Instrumentation Cable suitable for Maxi-Term-Point-connection,

meter marking


Technical data

Cable structure

Properties

Special PVC data transmission cable


adapted to DINVDE0815
Conductor resistance (loop)
max.73,6Ohm/km
Temperature range
flexing -5 C to +50 C
fixed installation -40 C to +70 C
Operating top level voltage
max. 600 V
(not for purposes of power installation)
Test voltage
core/core 2000 V
core/screen 2000 V
Insulation resistance
core/core min.100MOhmxkm
core/screen min.100MOhmxkm
Mutual capacitance at 800 Hz
max. 100 nF/km
(this value may be exceeded by 20% with
a make-up to 4 pairs)
Impedance
at 1kHz approx.370Ohm
at 10kHz approx.130Ohm
Capacity unbalance at800Hz
max. 200pF/100m
(20% of the values, but one value up to
400pF is allowed)
Line attenuation
at 1 kHz approx.1,2dB/km
at 10 kHz approx.3,0dB/km
Cross-talk attenuation at 10kHz
and cable length of 500m min.60dB
Minimum bending radius
approx. 7,5x cable

Bare copper stranded wires 0,5mm


(7x0,3mm)
PVC core insulation
Cores colour coded
Cores twisted in pairs (approx.20
pitch/m 50mm) 4pairs stranded to a unit
Units stranded in concentric layers
Electrostatic screen of plastic coated
aluminium foil and drain-wire tinned,
0,5 mm (7x0,3 mm)
PVC outer jacket
Colour grey (RAL7032) or blue (RAL5015)
with meter marking, change-over in 2011
Core colours:
pair-no.1, a-core=blue, b-core=red
pair-no.2, a-core=grey, b-core=yellow
pair-no.3, a-core=green, b-core=brown
pair-no.4, a-core=white, b-core=black
(4 pairs = 1 unit)

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The pairs are twisted with short pitches and
different lay-lengths which lead to good
crosstalk attenuation values in a unit
The static screen protects the transmission
circuits against outer electrical
interferences
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
Cop.weight including drain-wire.
Also available halogen-free type RD-H(St)H
on request.
Maxi-Termi-Point = registered trade mark
AMP.

Application
The data transmission cables RD-Y(St)Y are used in measurement and control technology such as in control rooms of industrial plants and
power stations. The cables serves for transmission of analog and digital signals up to frequencies of approx. 10 kHz.
These cables offer considerable advantages by using the quick and economical connecting possibilities in Maxi-Termi-Point technique. This
solderless connecting technique is defined by a compression termination that employs a spring-clip for the connection of the cable to a
square rigid post without pre-stripping. For this technique it is necessary to have an exact 7-core stranded conductor and a Semi-Rigid-PVC.
Suitable for fixed installation only inside of buildings. Cable with a blue outer jacket is used for intrinsic safe installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
20140
20141
20142
20143
20144
20145
20146
20147
20148
20189
20190
20191
20192
20193
20194
20195
20196
20197

No.pairs x
cross-sec.
mm
2 x 2 x 0,5
4 x 2 x 0,5
8 x 2 x 0,5
12 x 2 x 0,5
16 x 2 x 0,5
24 x 2 x 0,5
32 x 2 x 0,5
48 x 2 x 0,5
96 x 2 x 0,5
2 x 2 x 0,5
4 x 2 x 0,5
8 x 2 x 0,5
12 x 2 x 0,5
16 x 2 x 0,5
24 x 2 x 0,5
32 x 2 x 0,5
48 x 2 x 0,5
96 x 2 x 0,5

Jacket colour

Core
approx. mm

grey
grey
grey
grey
grey
grey
grey
grey
grey
blue
blue
blue
blue
blue
blue
blue
blue
blue

1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5

No.
units
1
2
3
4
6
8
12
24
1
2
3
4
6
8
12
24

Outer
approx. mm
6,0
8,0
11,5
12,0
13,7
16,3
21,0
23,0
30,5
6,0
8,0
11,5
12,0
13,7
16,3
21,0
23,0
30,5

Cop.
weight
kg/km
25,0
45,0
85,0
125,0
165,0
245,0
325,0
485,0
965,0
25,0
45,0
85,0
125,0
165,0
245,0
325,0
485,0
965,0

Weight
approx.
kg/km
61,0
96,0
160,0
210,0
282,0
330,0
530,0
730,0
1400,0
61,0
96,0
160,0
210,0
282,0
330,0
530,0
730,0
1400,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

Dimensions and specifications may be changed without prior notice. (RB01)

B 26
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

RD-Y(St)Yv / RD-Y(St)YY

reinforced (double) outer jacket, instrumentation

cable, Maxi-Termi-Point, meter marking




Technical data

Cable structure

Properties

Special PVC data transmission cable


adapted to DINVDE0815 and0816
Conductor resistance (loop)
max.73,6Ohm/km
Temperature range
flexing -5 C to +50 C
fixed installation -40 C to +70 C
Operating top level voltage
max. 600 V (not for purposes of
high current and power installation)
Test voltage
core/core 2000 V
core/screen 2000 V
Insulation resistance
core/core min. 100 MOhm x km
core/screen min. 100 MOhm x km
Mutual capacitance
at 800 Hz max. 100 nF/km
(this value may be exceeded by 20% with
a make-up to 4pairs)
Impedance
at 1 kHz approx. 370 Ohm
at 10 kHz approx. 130 Ohm
Capacity unbalance at 800 Hz
max. 200 pF/100 m
(20% of the values, but one value up to
400pF is allowed)
Line attenuation
at 1 kHz approx. 1,2 dB/km
at 10 kHz approx. 3,0 dB/km
Cross-talk attenuation
at 10 kHz and cable length of 500m
min.60dB
Minimum bending radius
approx. 7,5x cable

Bare copper stranded wires 0,5mm


(7x0,3mm)
PVC core insulation
Cores colour coded
Cores twisted in pairs(approx.
20pitch/m 50mm)
4pairs stranded to a unit, units stranded
in concentric layers
Static screen (St) of plastic coated metal
foil with stranded tinned drain wire,
0,5mm (7x0,3mm)
PVC outer jacket
Colour grey (RAL7032)
with meter marking, change-over in 2011
Core colours:
pair-no.1, a-core=blue, b-core=red
pair-no.2, a-core=grey, b-core=yellow
pair-no.3, a-core=green, b-core=brown
pair-no.4, a-core=white, b-core=black
(4 pairs = 1 unit)

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The static screen protects the transmission
circuits against outer electrical
interferences
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
Cop.Weight including drain-wire.
Maxi-Termi-Point = registered trade mark
AMP.

Application
The data transmission cables RD-Y(St)Yv are used in measurement and control technology such as in control rooms of industrial plants and
power stations. The pairs are twisted with short pitches and different lay-lengths which lead to good crosstalk attenuation values in a unit.
The cables serves for transmission of analog and digital signals up to frequencies of approx. 10 kHz. These cables offer considerable advantages
by using the quick and economical connecting possibilities in Maxi-Termi-Point technique. This solderless connecting technique is defined
by a compression termination that employs a spring-clip for the connection of the cable to a square rigid post without pre-stripping. For
this technique it is necessary to have an exact 7-core stranded conductor and a Semi-Rigid-PVC. Suitable for fixed installation only inside of
buildings. With the reinforced PVC(-Yv) outer jacket these cables are suitable for fixed installation in inside buildings and also in open air and
in underground.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


RD-Y(St)Yv
Part
no.
20160
20161
20162
20163
20164
20165
20166
20167
20168

No.pairs x
cross-sec.
mm
2 x 2 x 0,5
4 x 2 x 0,5
8 x 2 x 0,5
12 x 2 x 0,5
16 x 2 x 0,5
24 x 2 x 0,5
32 x 2 x 0,5
48 x 2 x 0,5
96 x 2 x 0,5

Core
No.
approx. units
mm
2
2
1
2
2
2
3
2
4
2
6
2
8
2
12
2
24

Outer Cop.
Weight AWG-No.
approx. weight approx.
mm
kg/km kg/km
7,0
25,0
80,0
20
9,0
45,0
125,0
20
12,5
85,0
200,0
20
13,0
125,0
255,0
20
14,7
165,0
315,0
20
16,3
245,0
370,0
20
21,0
325,0
555,0
20
23,0
485,0
170,0
20
35,5
965,0
1300,0
20

RD-Y(St)YY
Part
no.
20180
20181
20182
20183
20184
20185
20186
20187
20188

No.pairs x
cross-sec.
mm
2 x 2 x 0,5
4 x 2 x 0,5
8 x 2 x 0,5
12 x 2 x 0,5
16 x 2 x 0,5
24 x 2 x 0,5
32 x 2 x 0,5
48 x 2 x 0,5
96 x 2 x 0,5

Core
No.
approx. units
mm
2
2
1
2
2
2
3
2
4
2
6
2
8
2
12
2
24

Outer Cop.
Weight AWG-No.
approx. weight approx.
mm
kg/km kg/km
7,5
25,0
90,0
20
9,5
45,0
140,0
20
13,0
85,0
220,0
20
14,0
125,0
275,0
20
15,7
165,0
350,0
20
17,3
245,0
470,0
20
28,0
325,0
620,0
20
24,0
485,0
850,0
20
36,5
965,0
1450,0
20

Dimensions and specifications may be changed without prior notice. (RB01)

B 27
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

RE-2Y(St)Yv

instrumentation cable, reinforced outer jacket, meter marking

Technical data

Cable structure

Properties

Special core insulation of PE


Conductor resistance
0,5 mm: max. 39,2 Ohm/km
0,75 mm: max. 24,6 Ohm/km
1,3 mm: max. 14,2 Ohm/km
Temperature range
flexing -5 C to +50 C
fixed installation -40 C to +70 C
Operating top level voltage
max. 300 V (not for purposes of
high current and power installation)
Test voltage
core/core 2000 V
core/screen 1000 V
Insulation resistance
min. 5 GOhm x km
Mutual capacitance at 800 Hz
core/core 0,5 mm: 60 nF/km
for 1 and 2 pairs: 75 nF/km
core/core 0,75 mm: 65 nF/km
for 1 and 2 pairs: 110 nF/km
core/core 1,3 mm: 75 nF/km
for 1 and 2 pairs: 100 nF/km
Inductance max. 0,75 mH/km
Cross-talk attenuation
min. 0,88 dB/km at 60 kHz
Minimum bending radius
approx. 7,5x cable

Bare copper stranded wires


0,5 mm (7x0,3mm)
0,75 mm (7x0,37mm)
1,3 mm (7x0,49mm)
Core insulation of PE
Cores colours with numbering
pair: a-core black, b-core white
triple:a-core black, b-core white, c-core red
with number print 1/1, 2/2, etc.
Cores twisted to pairs with optimum pitch
Pairs stranded in layer + 1communication
core 0,5mm, PE-insulated, orange
(communication core for multicore version)
Core wrapping with foil
Electrostatic screen (St) of plastics-coated
metal foil and tinned drain-wire 0,5mm
(7x0,3mm)
PVC outer jacket, reinforced
Colour black (RAL9005) or blue (RAL5015)
with blue outer jacket for hazardous areas
to hazard type -i- for intrinsically safe
installation according to DINEN60079-14
and IEC60079-14 section12.2.2 (VDE0165
part1)
with meter marking, change-over in 2011
Wall-thickness to DINVDE0816 part1,
table7, col.1


Self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The electrostatic screen protect the
screened pairs against outer electrostatic
interference fields
Low level of line attenuations and low
mutual capacitances enable long
transmission distances and fast pulse
acceleration
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
Cop.Weight including communication core
and drain-wire.
Control cable with blue outer jacket, see
catalog part A.

Application
Instrumentation cables are used in data processing and process control.
Instrumentation cables are suitable for fixed installations in damp locations, in open spaces and for underground laying.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.pairs x
cross-sec.
mm
20099
1 x 2 x 0,5
20100
2 x 2 x 0,5
20101
4 x 2 x 0,5
20233
6 x 2 x 0,5
20102
8 x 2 x 0,5
20103
10 x 2 x 0,5
20104
12 x 2 x 0,5
20105
16 x 2 x 0,5
20106
20 x 2 x 0,5
20107
24 x 2 x 0,5
20108
36 x 2 x 0,5
20109
48 x 2 x 0,5
20149
1 x 2 x 0,75
20150
2 x 2 x 0,75
20151
4 x 2 x 0,75
20152
8 x 2 x 0,75
20153
10 x 2 x 0,75
20154
12 x 2 x 0,75
20155
16 x 2 x 0,75
20156
20 x 2 x 0,75
20157
24 x 2 x 0,75
20158
36 x 2 x 0,75
20159
48 x 2 x 0,75
20125
1 x 2 x 1,3
20132
1 x 3 x 1,3
20126
2 x 2 x 1,3
20127
4 x 2 x 1,3
20234
6 x 2 x 1,3
20128
8 x 2 x 1,3
20129
12 x 2 x 1,3
20130
16 x 2 x 1,3
20131
24 x 2 x 1,3

Jacket
colour
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black

Outer
approx.
mm
8,2
10,2
11,5
12,6
13,8
14,9
15,7
17,5
18,8
20,2
24,1
27,5
7,9
10,6
11,8
14,6
16,1
17,0
19,0
21,5
23,2
28,2
32,0
9,4
9,7
11,7
13,5
16,0
17,1
19,3
22,0
26,5

Cop.
weight
kg/km
15,0
30,0
50,0
70,0
90,0
110,0
130,0
170,0
210,0
250,0
370,0
490,0
20,0
35,0
65,0
125,0
154,0
185,0
245,0
298,0
365,0
532,0
708,0
31,0
44,0
62,0
114,0
168,0
218,0
322,0
426,0
684,0

Weight
approx.
kg/km
74,0
117,0
140,0
190,0
215,0
220,0
280,0
352,0
385,0
468,0
656,0
854,0
74,0
123,0
164,0
258,0
305,0
350,0
445,0
520,0
620,0
940,0
1250,0
102,0
116,0
161,0
230,0
310,0
377,0
515,0
656,0
952,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
-


Part no. No.pairs x
cross-sec.
mm
20235
1 x 2 x 0,5
20236
2 x 2 x 0,5
20237
4 x 2 x 0,5
20238
6 x 2 x 0,5
20239
8 x 2 x 0,5
20240
10 x 2 x 0,5
20241
12 x 2 x 0,5
20242
16 x 2 x 0,5
20243
20 x 2 x 0,5
20244
24 x 2 x 0,5
20245
36 x 2 x 0,5
20246
48 x 2 x 0,5
20169
1 x 2 x 0,75
20170
2 x 2 x 0,75
20171
4 x 2 x 0,75
20172
8 x 2 x 0,75
20173
10 x 2 x 0,75
20174
12 x 2 x 0,75
20175
16 x 2 x 0,75
20176
20 x 2 x 0,75
20177
24 x 2 x 0,75
20178
36 x 2 x 0,75
20179
48 x 2 x 0,75
20247
1 x 2 x 1,3
20255
1 x 3 x 1,3
20248
2 x 2 x 1,3
20249
4 x 2 x 1,3
20250
6 x 2 x 1,3
20251
8 x 2 x 1,3
20252
12 x 2 x 1,3
20253
16 x 2 x 1,3
20254
24 x 2 x 1,3

Jacket
colour
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue

Outer
approx.
mm
8,2
10,2
11,5
12,6
13,8
14,9
15,7
17,5
18,8
20,2
24,1
27,5
7,9
10,6
11,8
14,6
16,1
17,0
19,0
21,5
23,2
28,2
32,0
9,4
9,7
11,7
13,5
16,0
17,1
19,3
22,0
26,5

Cop.
weight
kg/km
15,0
30,0
50,0
70,0
90,0
110,0
130,0
170,0
210,0
250,0
370,0
490,0
20,0
35,0
65,0
125,0
154,0
185,0
245,0
298,0
365,0
532,0
708,0
31,0
44,0
62,0
114,0
168,0
218,0
322,0
426,0
684,0

Weight
approx.
kg/km
74,0
117,0
140,0
190,0
215,0
220,0
280,0
352,0
385,0
468,0
656,0
854,0
74,0
123,0
164,0
258,0
305,0
350,0
445,0
520,0
620,0
940,0
1250,0
102,0
116,0
161,0
230,0
310,0
377,0
515,0
656,0
952,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
-

Dimensions and specifications may be changed without prior notice. (RB01)

B 28
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

RE-2Y(St)Yv PiMF

Instrumentation cable, pairs screened, reinforced outer

jacket, meter marking




Technical data

Cable structure

Properties

Special core insulation of PE


Conductor resistance
0,5 mm: max. 39,2 Ohm/km
1,3 mm: max. 14,2 Ohm/km
Temperature range
flexing -5 C to +50 C
fixed installation -40 C to +70 C
Operating top level voltage
max. 300 V (not for purposes of high
current and power installation)
Test voltage
core/core 2000 V
core/screen 1000 V
Insulation resistance
min. 5 GOhm x km
Mutual capacitance
(nominal value at 800 Hz)
core/core 0,5 mm: 75 nF/km
core/core 1,3 mm: 100 nF/km
Inductance max. 0,75 mH/km
Cross-talk attenuation
min. 1,02 dB/km at 60 kHz
Minimum bending radius
approx. 7,5x cable

Bare copper stranded wires


0,5mm (7x0,3mm)
1,3 mm (7x0,49mm)
Core insulation of PE
Cores colours with numbering
a-core black
b-core white
with number print 1/1, 2/2, etc.
Cores twisted in pairs with optimum pitch
PiMF (pair in metal foil):
foil taping, drain-wire
Cu-bare 0,6mm, plastic coated alu-foil
and plastic foil
PiMFe stranded in layer,
1 communication core 0,5mm,
PE-insulated orange (communication core
for multicore version)
Electrostatic screen (St) of plastics-coated
metal foil and tinned drain-wire 0,5mm
(7x0,3mm)
PVC outer jacket, reinforced, black
(RAL9005) or blue (RAL5015)
with meter marking, change-over in 2011
Wall-thickness to DINVDE0816 part1,
table7, col.1
with blue outer jacket for hazardous areas
to hazard type -i- for intrinsically safe
installation according to DINEN60079-14
and IEC60079-14 section12.2.2 (VDE0165
part1)

self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers.


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
Cop.weight including communication core
and drain-wire.
Control cable with blue outer jacket, see
catalog part A.

Application
Instrumentation cables are used in data processing and process control. The individual screening of the pairs guarantee high cross-talk
attenuation. The electrostatic screen protect the screened pairs against outer electrostatic interference fields. Low level of line attenuations
and low mutual capacitances enable long transmission distances and fast pulse acceleration. Instrumentation cables are suitable for fixed
installations in damp locations, in open spaces and for underground laying.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.pairs x


cross-sec.
mm
20115
2 x 2 x 0,5
20116
4 x 2 x 0,5
21535
6 x 2 x 0,5
20117
8 x 2 x 0,5
20118
10 x 2 x 0,5
20119
12 x 2 x 0,5
20120
16 x 2 x 0,5
20121
20 x 2 x 0,5
20122
24 x 2 x 0,5
20123
36 x 2 x 0,5
20124
48 x 2 x 0,5
20133
2 x 2 x 1,3
20134
4 x 2 x 1,3
21536
6 x 2 x 1,3
20135
8 x 2 x 1,3
20136
12 x 2 x 1,3
20137
16 x 2 x 1,3
20138
24 x 2 x 1,3

Jacket
colour
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black
black

Outer
approx.
mm
12,0
13,2
14,0
14,9
16,7
17,6
19,8
21,5
23,6
27,0
32,3
12,7
15,2
16,7
19,1
21,4
24,7
29,4

Cop.
weight
kg/km
35,0
60,0
82,0
121,0
136,0
161,0
212,0
262,0
313,0
465,0
616,0
68,0
124,0
178,0
239,0
353,0
468,0
697,0

Weight
approx.
kg/km
128,0
170,0
215,0
246,0
261,0
351,0
430,0
496,0
604,0
850,0
1115,0
184,0
269,0
370,0
442,0
593,0
789,0
1104,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
-


Part no. No.pairs x
cross-sec.
mm
21537
2 x 2 x 0,5
21538
4 x 2 x 0,5
21539
6 x 2 x 0,5
21540
8 x 2 x 0,5
21541
10 x 2 x 0,5
21542
12 x 2 x 0,5
21543
16 x 2 x 0,5
21544
20 x 2 x 0,5
21545
24 x 2 x 0,5
21546
36 x 2 x 0,5
21547
48 x 2 x 0,5
21548
2 x 2 x 1,3
21549
4 x 2 x 1,3
21550
6 x 2 x 1,3
21551
8 x 2 x 1,3
21552
12 x 2 x 1,3
21553
16 x 2 x 1,3
21554
24 x 2 x 1,3

Jacket
colour
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue

Outer
approx.
mm
12,0
13,2
14,0
14,9
16,7
17,6
19,8
21,5
23,6
27,0
32,3
12,7
15,2
16,7
19,1
21,4
24,7
29,4

Cop.
weight
kg/km
35,0
60,0
82,0
121,0
136,0
161,0
212,0
262,0
313,0
465,0
616,0
68,0
124,0
178,0
239,0
353,0
468,0
697,0

Weight
approx.
kg/km
128,0
170,0
215,0
246,0
261,0
351,0
430,0
496,0
604,0
850,0
1115,0
184,0
269,0
370,0
442,0
593,0
789,0
1104,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
-

Dimensions and specifications may be changed without prior notice. (RB01)

B 29
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

J-2Y(St)Y

St III Bd 16 Mbits/s (Kat. 3) ISDN/EDV (Z = 100 Ohm), meter marking

Technical data

Cable structure

Properties

Special core insulation of PE Adapted to


DINVDE0815 and0816
Conductor loop-resistance
max. 130 Ohm/km
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +70 C
Operating peak voltage 300 V
(not for purposes of high current and
power installation)
Test voltage 800 V
Insulation resistance
min. 5 GOhm x km
Mutual capacitance 48 nF/km
Characteristic impedance (Z)
at 4-16 MHz: 100 Ohm 15%
Capacitance unbalance
K1 max. 400 pF/300 m
K9-K12 max. 100 pF/300 m
Rel. velocity ratio approx. 0,66
Attenuation at
1 MHz: 28 dB/km
4 MHz: 47 dB/km
5 MHz: 51 dB/km
10 MHz: 65 dB/km
15 MHz: 76 dB/km
16 MHz: 78 dB/km
20 MHz: 89 dB/km
Cross-talk attenuation
from 4 MHz up to 16 MHz
for 2 pairs: min. 40 dB
4 pairs and above: min. 25 dB
Minimum bending radius
stationary approx. 10x cable

Bare, solid copper conductor 0,6mm


Core insulation of PE Colour coding to
DINVDE0815
Conductors twisted to quads
5 quads twisted to units
Static screen of plastics coated alu foil with
drain wire 0,6mm
PVC outer sheath, to DINVDE0207 part5
Colour grey (RAL7032)
with meter marking, change-over in 2011

PVC sheath:
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers.

Application
Used as data transmission and connection cable suitable for fixed installation in and under plaster, for data transmission applications, for
periphery instrument data processing computers.
Suitable for transmission of analog- and digital signals up to 16 Mbit/s. High cross-talk attenuation values.
Suitable as connecting cable for periphery equipment, data processing systems, monitors, Printers and cash register systems.
The static screen (St) screen assures a disturbance-free data and signal transmission for measuring and control systems.
These cables are not allowed for purposes of high current and power installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
33200
33201
33202
33203
33204
33205

No.pairs x
cross-sec.
mm
2 x 2 x 0,6
4 x 2 x 0,6
6 x 2 x 0,6
8 x 2 x 0,6
10 x 2 x 0,6
20 x 2 x 0,6

Outer
Cop.
approx. mm weight
kg/km
6,1
13,0
7,5
24,0
7,7
35,0
8,8
46,0
8,9
58,0
12,7
116,0

Weight
approx.
kg/km
44,0
80,0
86,0
105,0
112,0
218,0


Part no.
33206
33207
33208
33209
33210
33211

No.pairs x
cross-sec.
mm
30 x 2 x 0,6
40 x 2 x 0,6
50 x 2 x 0,6
60 x 2 x 0,6
80 x 2 x 0,6
100 x 2 x 0,6

Outer
Cop.
approx. mm weight
kg/km
14,0
172,0
16,8
229,0
17,5
266,0
17,9
342,0
24,4
455,0
26,0
588,0

Weight
approx.
kg/km
302,0
376,0
480,0
560,0
748,0
940,0

Dimensions and specifications may be changed without prior notice. (RB01)

B 30
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JE-Y(St)Y

Bd Si Industry-Elektronic Cable according to DIN VDE 0815

Technical data

Cable structure

Properties

Special core insulation to


DINVDE0815/DIN57815
Conductor resistance at 20 C
36,6 Ohm/km
Temperature range
flexing -5 C to +50 C
fixed installation -30 C to +70 C
Nominal voltage 225 V
(not for purposes of high current and
power installation)
Test voltage
core/core 500 V
core/screen 2000 V
Insulation resistance
min. 100 MOhm x km
Mutual capacitance
max. 100 pF/m (the value can exceed of
20% by cables up to 4 pairs)
Capacitance unbalance
max. 200 pF/100 m
Inductance approx. 0,70 mH/km
Attenuation at 800 Hz
approx. 1,1 dB/km
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Minimum bending radius
stationary approx. 6x cable
Caloric load values
see table Technical Informations

Solid plain copper conductor wire 0,8mm


Special PVC core insulation YI3, to
DINVDE0207 part4
Simatic colour coded to DINVDE0815
Cores stranded in pairs with optimal
lay-length
4pairs stranded to a unit
Units stranded in layer
Polyester foil wrap
PVC coated aluminium foil screen
Copper drain-wire, bare
Special PVC outer sheath YM1, to
DINVDE0207 part5
Colour grey (RAL7032) or blue (RAL5015)
with blue outer jacket for hazardous areas
to hazard type -i- for intrinsically safe
installation according to DINEN60079-14
and IEC60079-14 section12.2.2 (VDE0165
part1)

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

Also availabel in a halogen-free version.


(see also content "Halogen-free Security
Cables and Wires".
Control cable with blue outer jacket, see
catalog part A.

Application
This cable type is especially suited for transmission of signals and measurements in the fields of electronics and for data transmission in
computers. Suitable for fixed installation in and under plaster, in dry and moist environments as well as in the open.
These cables are not allowed for purposes of high current and power installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.pairs x


cross-sec.
mm
48500
1 x 2 x 0,8
48501
2 x 2 x 0,8
48502
4 x 2 x 0,8
48503
8 x 2 x 0,8
48504
12 x 2 x 0,8
48505
16 x 2 x 0,8
48506
20 x 2 x 0,8
48507
32 x 2 x 0,8
48508
40 x 2 x 0,8
48509
80 x 2 x 0,8

Jacket
colour
grey
grey
grey
grey
grey
grey
grey
grey
grey
grey

Outer
approx.
mm
5,2
5,8
7,7
10,5
11,5
12,4
14,3
18,0
19,5
28,1

Cop.
weight
kg/km
20,0
25,0
45,0
85,0
126,0
166,0
206,0
327,0
407,0
809,0

Weight
approx.
kg/km
43,0
60,0
95,0
157,0
224,0
290,0
350,0
545,0
660,0
1160,0


Part no. No.pairs x
cross-sec.
mm
48519
1 x 2 x 0,8
48520
2 x 2 x 0,8
48521
4 x 2 x 0,8
48522
8 x 2 x 0,8
48523
12 x 2 x 0,8
48524
16 x 2 x 0,8
48525
20 x 2 x 0,8
48526
32 x 2 x 0,8
48527
40 x 2 x 0,8
48528
80 x 2 x 0,8

Jacket
colour
blue
blue
blue
blue
blue
blue
blue
blue
blue
blue

Outer
approx.
mm
5,2
5,8
7,7
10,5
11,5
12,4
14,3
18,0
20,3
28,1

Cop.
weight
kg/km
20,0
25,0
45,0
85,0
126,0
166,0
206,0
327,0
407,0
809,0

Weight
approx.
kg/km
43,0
60,0
95,0
157,0
224,0
290,0
350,0
545,0
660,0
1160,0

Dimensions and specifications may be changed without prior notice. (RB01)

B 31
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JE-LiYCY

Bd Si Industry-Elektronic Cable according to DIN VDE 0815

Technical data

Cable structure

Properties

Special PVC core insulation to


DINVDE0815/DIN57815
Conductor resistance at 20 C
39,2 Ohm/km
Temperature range
flexing -5 C to +50 C
fixed installation -30 C to +70 C
Nominal voltage 225 V
Test voltage
core/core 500 V
core/screen 2000 V
Insulation resistance
min. 100 MOhm x km
Mutual capacitance max. 100 pF/m
(the value can exceed of 20% by cables up
to 4 pairs)
Capacitance unbalance
max. 200 pF/100 m
Inductance approx. 0,70 mH/km
Attenuation at 800 Hz
approx. 1,1 dB/km
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Minimum bending radius
stationary approx. 5xcable

Bare copper strands 7x0,30mm


Special PVC core insulation YI3, to
DINVDE0207 part4
Simatic colour coded to DINVDE0815
Cores stranded in pairs with optimal
lay-length
4 pairs laid up to a unit
Units stranded in layer
Polyester foil wrap
Bare or tinned copper wire braided,
0,2mm screening, approx.85% coverage
Special PVC outer sheath YM1, to
DINVDE0207 part5
Colour grey (RAL7032) or blue (RAL5015)
with blue outer jacket for hazardous areas
to hazard type -i- for intrinsically safe
installation according to DINEN60079-14
and IEC60079-14 section12.2.2 (VDE0165
part1)

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Features Suitable for cut-clamp technics
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
Also availabel in a halogen-free version.
(see also content "Halogen-free Security
Cables and Wires")
Control cable with blue outer jacket, see
catalog part A.

Application
This cable type is especially suited for transmission of signals and measurements in the fields of electronics and for data transmission in
computers. Suitable for flexing and fixed installation in dry and moist environments in and under plaster as well as in the open for fixed
installation on outer walls of buildings.
These cables are not allowed for purposes of high current and power installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.pairs x
cross-sec.
mm
48510
2 x 2 x 0,5
48511
4 x 2 x 0,5
48512
8 x 2 x 0,5
48513
12 x 2 x 0,5
48514
16 x 2 x 0,5
48515
20 x 2 x 0,5
48516
24 x 2 x 0,5
48517
32 x 2 x 0,5
48518
40 x 2 x 0,5

Jacket
colour
grey
grey
grey
grey
grey
grey
grey
grey
grey

Outer
approx.
mm
6,9
9,2
13,8
14,6
15,9
17,4
19,4
24,9
25,2

Cop.
weight
kg/km
51,0
87,0
144,0
196,0
249,0
299,0
348,0
444,0
537,0

Weight
approx.
kg/km
94,0
154,0
259,0
340,0
431,0
494,0
604,0
737,0
844,0

AWG-No.
20
20
20
20
20
20
20
20
20


Part no. No.pairs x
cross-sec.
mm
48529
2 x 2 x 0,5
48530
4 x 2 x 0,5
48531
8 x 2 x 0,5
48532
12 x 2 x 0,5
48533
16 x 2 x 0,5
48534
20 x 2 x 0,5
48535
24 x 2 x 0,5
48536
32 x 2 x 0,5
48537
40 x 2 x 0,5

Jacket
colour
blue
blue
blue
blue
blue
blue
blue
blue
blue

Outer
approx.
mm
6,9
9,2
13,8
14,6
15,9
17,4
19,4
24,9
25,2

Cop.
weight
kg/km
51,0
87,0
144,0
196,0
249,0
299,0
348,0
444,0
537,0

Weight
approx.
kg/km
94,0
154,0
259,0
340,0
431,0
494,0
604,0
737,0
844,0

AWG-No.
20
20
20
20
20
20
20
20
20

Dimensions and specifications may be changed without prior notice. (RB01)

B 32
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JE-LiHCH

Bd industry electronic cable, halogen-free, accordingtoVDE0815

Technical data

Cable structure

Properties

Industry-Electronic cable according to


DINVDE0815
Loop resistance at 20 C
39,2 Ohm/km
Temperature range
flexing -5 C to +50 C
fixed installation -30 C to +70 C
Operating top level voltage
225 V (not for purposes of high current
and power installation)
Test voltage U eff.
core/core 500 V
core/screen 2000 V
Insulation resistance
min. 100 MOhm x km
Mutual capacitance
max. 120 nF/km at 800 Hz (this values may
be extended at 20% with a make-up up to
4 pairs)
Capacitance unbalance
max. 200 pF/100 m (20% of the values, but
one value up to 400 pF is allowed)
Minimum bending radius
approx. 7,5x cabel
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Caloric load values
see Technical Informations

Bare copper, 7x0,3 mm 0,5 mm


Halogen-free core insulation, compound
type HI1 or HI2 to DINVDE0207 part23,
insulation wall thickness 0,3mm
Core identificationto DINVDE0815 (with
ring colours and ring groups)
2 cores twisted in pair, 4 pairs to a unit and
several units stranded in layers (for 2 pairs
cable, 4 cores stranded to a quad)
Core wrapping with plastic tape
Copper braided screening, wire 0,2mm,
approx. 85% coverage
Outer jacket halogen-free, grey RAL7032,
compound type HM1 or HM2 to
DINVDE0207 part24
Jacket wall-thickness to DINVDE0815

Not for purposes of high current and


power installation as well as underground
laying
Tests
Flame test to VDE0482-332-3,BS4066
part3/ DINEN60332-3/ IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
(equivalent DINVDE0472 part816)


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
LS0H = Low Smoke Zero Halogen-free.

Application
Halogen-free installation cables with improved characteristics in the case of fire are used for telephone transmission, measuring and signal
purposes.
The copper screened design (C) protects the transmission circuits against electrical interferences.
A fire propagation is prevented through high oxygen index of the insulation material and produce no corrosive gases in case of fire. Those
are preferably used for telecommunication indoor installations and in special cases the outdoor installation is permitted under protection
against sunlight.
These cables are suitable for fixed installation in areas with danger of fire, in dry and damp environments as well as on and under plaster.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part
no.
34350
34351
34352
34353

No.pairs x
cross-sec.
mm
2 x 2 x 0,5
4 x 2 x 0,5
8 x 2 x 0,5
12 x 2 x 0,5

Core
No.
approx. units
mm
1,6
1,6
1
1,6
2
1,6
3

Outer Cop.
Weight AWG-No.
approx. weight approx.
mm
kg/km kg/km
7,6
44,0
102,0
20
10,0
80,0
168,0
20
11,8
152,0
297,0
20
13,5
192,0
357,0
20


Part
no.
34354
34355
34356

No.pairs x
cross-sec.
mm
20 x 2 x 0,5
32 x 2 x 0,5
40 x 2 x 0,5

Core
No.
approx. units
mm
1,6
5
1,6
8
1,6
10

Outer Cop.
Weight AWG-No.
approx. weight approx.
mm
kg/km kg/km
17,0
288,0
555,0
20
18,0
439,0
852,0
20
21,7
531,0
1005,0
20

Dimensions and specifications may be changed without prior notice. (RB01)

B 33
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

RD-H(ST)H

Bd instrumentation cable, halogen-free

Technical data

Cable structure

Properties

Halogen-free data transmission cable


adapted to DINVDE0815
Conductor resistance
max. 73,6 Ohm/km (0,5 mm)
max. 36,8 Ohm/km (1,0 mm)
Temperature range
flexing -5 C to +50 C
fixed installation to +70 C
Operating top level voltage 
(not for purposes of high current and
power installation)
max. 225 V
Test voltage
core/core 500 V
core/screen 2000 V
Insulation resistance
min. 100 MOhm x km
Mutual capacitance
at 800 Hz max. 100 nF/km
(this value may be exceeded by 20% with
a make-up up to 4 pairs)
Impedance at 1 kHz (nominal values)
450 Ohm (0,5 mm)
320 Ohm (1,0 mm)
Capacity unbalance
at 800 Hz max. 200 pF/100 m
(20% of the values, but one value up to 200
pF is allowed)
Cross-talk attenuation
at min. 10 kHz, 60 dB/500 m
Line attenuation at 1 kHz (nominal
values)
1,2 dB/km (0,5 mm)
0,9 dB/km (1,0 mm)
Bending radius
approx. 7,5x cable

Bare copper stranded wires 0,5mm (7x0,3)


or 1,0mm (7x0,43)
Core insulation, halogen-free polymer
compound
Cores twisted in pairs, with short lay-length
(approx. 20 pitch/m 50mm)
4 pairs stranded to a unit
Holding tape units with number coding
Units stranded in concentric layers
Core wrapping
Electrostatic screen of plastic coated
aluminium foil and drain wire tinned,
0,5mm
Outer jacket, halogen-free, polymer
compound, flame resistant
Colour grey (RAL 7032)
Core colours
pair no./a-core/b-core
1/blue/red
2/grey/yellow
3/green/brown
4/white/black
(4 pairs 1 unit)

The static screen protects the transmission


circuits against outer electrical
interferences
The halogen-free cables prevent the fire
propagation and compared to PVC cables
exist only a low smoke density under flame
influence
This results no decomposition products
which destroy equipments, machines and
buildings by corrosion
Tests
Flame test to VDE0482-332-3, BS4066
part3/ DINEN60332-3/ IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Smoke density according to VDE0482
part1034-1+2, IEC61034-1+2/ DIN EN
61034-1+2  BS7622 part1+2 (equivalent
DINVDE0472 part816)


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application
The halogen-free data transmission cable RD-H(St)H are used for measurement and control technology for transmission of analog and digital
signals up to frequencies of approx. 10kHz. The twisted pairs with short pitches (<50mm for 0,5mm) and different lay-lengths which lead
good cross-talk attenuation values in a unit.
These cables are used in inside buildings (in special cases in open air, but with sufficient protection against sunlight is necessary).
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
20200
20201
20202
20203
20204
20205
20206
20207
20208
20209
20210
20211
20212
20213
20214
20215

No.pairs x
cross-sec.
mm
2 x 2 x 0,5
4 x 2 x 0,5
8 x 2 x 0,5
12 x 2 x 0,5
16 x 2 x 0,5
20 x 2 x 0,5
24 x 2 x 0,5
28 x 2 x 0,5
32 x 2 x 0,5
36 x 2 x 0,5
40 x 2 x 0,5
44 x 2 x 0,5
48 x 2 x 0,5
64 x 2 x 0,5
80 x 2 x 0,5
96 x 2 x 0,5

Outer
Cop.
approx. mm weight
kg/km
7,0
26,0
9,0
46,0
11,6
86,0
13,5
127,0
14,0
167,0
16,0
209,0
17,5
250,0
19,0
290,0
21,0
331,0
21,5
372,0
22,5
412,0
23,5
453,0
24,0
494,0
30,0
658,0
33,0
821,0
36,0
986,0

Weight
approx.
kg/km
70,0
110,0
190,0
240,0
300,0
360,0
420,0
480,0
570,0
614,0
680,0
700,0
790,0
1040,0
1300,0
1510,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20


Part no.
20216
20217
20218
20219
20220
20221
20222
20223
20225
20226
20227
20228
20229
20230
20231
20232

No.pairs x
cross-sec.
mm
2x2x1
4x2x1
8x2x1
12 x 2 x 1
16 x 2 x 1
20 x 2 x 1
24 x 2 x 1
28 x 2 x 1
32 x 2 x 1
36 x 2 x 1
40 x 2 x 1
44 x 2 x 1
48 x 2 x 1
64 x 2 x 1
80 x 2 x 1
96 x 2 x 1

Outer
Cop.
approx. mm weight
kg/km
9,0
47,0
12,0
89,0
16,5
172,0
17,5
255,0
19,5
338,0
21,0
423,0
23,0
507,0
27,0
590,0
29,0
674,0
30,0
757,0
31,0
841,0
34,0
924,0
32,5
1008,0
39,0
1342,0
43,0
1676,0
47,0
2016,0

Weight
approx.
kg/km
110,0
190,0
320,0
435,0
560,0
680,0
800,0
905,0
1080,0
1260,0
1330,0
1410,0
1550,0
2000,0
2470,0
2970,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17

Dimensions and specifications may be changed without prior notice. (RB01)

B 34
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Cables for Drag Chains

C1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Cables for Drag Chains

HELUKABEL delivers exible control cables with


different insulations and outer jacket materials,
screened and unscreened with an optimum of
price-earning ratio.
Control cables can be used in machinery
production and production lines as direct line or
connection cable for measuring, signal and control
features, for computer systems, for control
devices of tool making machines, conveyor belts
and conveyor systems.
It goes without saying that we also demand a high
quality standard for our control cable as well as for
all other cables.
We hold an extensive stock of cables.

C2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description

Page

PVC Cables for Drag Chains


JZ-HF,flexible, number coded, control cable for drag chains, oil resistant, meter marking .......................................................................
MULTISPEED 500-PVC,high flexible, safety against high bending in drag chain systems, oil resistant, low torsion, meter marking ..............................
JZ-HF-CY,high flexible, screened control cable for drag chains, oil resistant, EMC-preferred type, meter marking ........................................
MULTISPEED 500-C-PVC,high flexible, safety against high bending in drag chain systems, oil resistant, low torsion, screened, EMC-preferred type,
meter marking ....................................................................................................................................................................................

PUR Cables for Drag Chains


PUR-JZ-HF,high flexible, cable for drag chains, abrasion and coolant resistant, meter marking ......................................................................
MULTIFLEX 512 -PUR,special cable for drag chains, halogen-free, meter marking ................................................................................
MULTISPEED 500-PUR,safety against high bending in drag chain systems, low torsion, halogen-free, meter marking ............................................
PUR-JZ-HF-YCP,EMC-preferred type, cable for drag chains, screened, PUR-outer sheath, meter marking .......................................................
MULTIFLEX 512 -C-PUR,special cable for drag chains, halogen-free, screened, EMC-preferred type, meter marking .....................................
MULTISPEED 500-C-PUR,safety against high bending in drag chain systems, low torsion, halogen-free, EMC-preferred type, halogen-free,
meter marking ....................................................................................................................................................................................
MULTISPEED 500-TPE,high flexible, safety against high bending in drag chain systems, low torsion, halogen-free, meter marking .......................
MULTISPEED 500-C-TPE,safety against high bending in drag chain systems, low torsion, halogen-free, EMC-preferred type, meter marking ..........

Bio-Oil and microbial resistant Cables for Drag Chains


BIOFLEX-500 -JZ-HF,Bio-fuel resistant, abrasion resistant, recyclable environment friendly, bio-oil resistant , cable for drag chains, meter marking.........
BIOFLEX-500 -JZ-HF-C,Biofuel-resistant, abrasion-resistant, recyclable, environmentally friendly, drag-chain cable, bio-oil resistant , meter marking......
KOMPOSPEED JZ-HF-500,halogen-free, microbes resistant, cable for drag chains, meter marking .................................................................
KOMPOSPEED JZ-HF-500-C,halogen-free, microbes resistant, Cu-screened, EMC-preferred type, cable for drag chains, meter marking ..................
SUPERTRONIC -PVC,special cable for drag chains, meter marking ........................................................................................................
SUPERTRONIC -C-PVC,special cable for drag chains, EMC-preferred type, meter marking ..........................................................................
SUPERTRONIC -PUR,special cable for drag chains, meter marking ......................................................................................................
SUPERTRONIC -C-PUR,special cable for drag chains, halogen-free, EMC-preferred type, meter marking ......................................................
SUPER-PAAR-TRONIC-C-PUR,cable for drag chains, halogen-free, EMC-preferred type, meter marking ........................................................

1)

1)

C 5
C 7
C 8

C 10

C 12
C 14
C 16
C 17
C 19
C 21
C 22
C 24
C 26
C 27
C 29
C 30
C 31
C 32
C 33
C 34
C 35

C3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-HF
MULTISPEED 500-PVC
JZ-HF-CY

MULTISPEED 500-C-PVC

Photo: Fotolia.com

PVC Cables for Drag Chains


HELUKABEL delivers exible control cables with
different insulations and outer jacket materials,
screened and unscreened with an optimum of
price-earning ratio.

It goes without saying that we also demand a


high quality standard for our control cable as well
as for all other cables.
We hold an extensive stock of cables.

Control cables can be used in machinery production and production lines as direct line or
connection cable for measuring, signal and control features, for computer systems, for control
devices of tool making machines, conveyor belts
and conveyor systems.

C4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-HF

flexible, number coded, control cable for drag chains, oil

resistant, meter marking




Technical data

Cable structure

Properties

Special PVC control cable, extreme flexibility


due to special construction
Requirements adapted to DINVDE0281
part13
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, extra fine wire conductors,


to DINVDE0295 cl.6 col.4, BS6360 cl.6
and IEC60228 cl. 6
Core insulation of special PVC Z7225
Black cores with continuous white figure
imprint to DIN VDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
selected lay-length
Core wrapping with fleece
Special PVC outer sheath, TM5 to
DINVDE0281 part1 and HD21.1,
Colour grey (RAL 7001)
with meter marking, change-over in 2011

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Oil resistent to DIN/EN 60811-2-1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
when ordering.
screened analogue type:
JZ-HF-CY see page C 8

Application
JZ-HF cables are ideal for use in the machine tool industry, in robotics and machine production and anywhere where high flexibility is essential.
These cables have shown excellent performance in combination with standard cable trays. These cables are suitable for flexible use for
medium mechanical stresses with free movements.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
15001
15002
15003
15004
15005
15090
15006
15007
15008
15009
15010
15011
15012
15013
15014
15015
15016
15017
15018

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
7x0,5
10G0,5
12G0,5
14G0,5
16G0,5
18G0,5
20G0,5
25G0,5
30G0,5
34G0,5
36G0,5
42G0,5
50G0,5
61G0,5

Outer
Cop.
approx. mm weight
kg/km
5,0
9,6
5,3
14,0
5,7
19,0
6,4
24,0
7,5
34,0
7,5
34,0
9,1
48,0
9,2
58,0
9,8
67,0
10,3
77,0
11,1
86,0
11,6
96,0
13,4
120,0
13,7
144,0
15,0
163,0
15,0
173,0
16,1
202,0
17,9
240,0
19,6
290,0

Weight
approx.
kg/km
46,0
57,0
70,0
93,0
127,0
127,0
161,0
177,0
213,0
260,0
284,0
318,0
363,0
432,0
487,0
518,0
575,0
675,0
829,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20


Part no.
15019
15020
15021
15022
15023
15024
15025
15026
15027
15028
15029
15030
15031
15032
15033
15034
15035
15036
15091

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
10G0,75
12G0,75
14G0,75
16G0,75
18G0,75
20G0,75
25G0,75
30G0,75
34G0,75
36G0,75
42G0,75
50G0,75
61G0,75
65G0,75

Outer
Cop.
approx. mm weight
kg/km
5,4
14,4
5,7
22,0
6,4
29,0
7,0
36,0
8,3
50,0
10,1
72,0
10,2
86,0
10,9
101,0
11,5
115,0
12,1
130,0
12,8
144,0
14,9
180,0
15,2
216,0
16,6
245,0
16,6
259,0
18,1
302,0
20,0
360,0
22,1
432,0
22,7
439,0

Weight
approx.
kg/km
58,0
73,0
77,0
119,0
165,0
216,0
247,0
284,0
320,0
356,0
453,0
498,0
510,0
550,0
570,0
600,0
700,0
820,0
841,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18

Continuation

C5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-HF

flexible, number coded, control cable for drag chains, oil

resistant, meter marking

Part no.
15037
15038
15039
15040
15041
15042
15043
15044
15045
15046
15047
15048
15049
15050
15051
15052
15214
15053
15092
15054
15055
15056
15057
15058
15059
15060
15061
15062
15063
15064
15065
15066
15067
15068
15069
15070
15071
15072
15215
15216

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
10G1
12G1
14G1
16G1
18G1
20G1
25G1
30G1
34G1
36G1
41G1
42G1
50G1
61G1
65G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
10G1,5
12G1,5
14G1,5
16G1,5
18G1,5
20G1,5
25G1,5
30G1,5
34G1,5
36G1,5
42G1,5
50G1,5
60G1,5
61G1,5
65G1,5

Outer
Cop.
approx. mm weight
kg/km
5,7
19,0
6,0
29,0
6,8
38,0
7,4
48,0
8,8
67,0
10,7
96,0
10,8
115,0
11,6
134,0
12,2
154,0
13,0
173,0
13,6
192,0
15,8
240,0
16,4
288,0
17,8
326,0
17,8
346,0
19,3
403,0
19,3
403,0
21,2
480,0
23,7
586,0
24,4
624,0
6,4
29,0
6,8
43,0
7,4
58,0
8,3
72,0
9,9
101,0
11,9
144,0
12,1
173,0
12,9
202,0
13,6
230,0
14,5
259,0
15,2
288,0
17,8
360,0
18,2
432,0
19,7
490,0
19,7
518,0
21,5
605,0
23,7
720,0
25,3
864,0
26,2
878,0
27,2
936,0

Weight
approx.
kg/km
65,0
84,0
113,0
137,0
192,0
251,0
295,0
337,0
379,0
420,0
480,0
600,0
695,0
777,0
825,0
926,0
948,0
1092,0
1204,0
1400,0
91,0
117,0
147,0
181,0
273,0
344,0
391,0
457,0
523,0
590,0
650,0
801,0
958,0
1084,0
1135,0
1290,0
1521,0
1885,0
1916,0
1994,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16


Part no.
15073
15074
15075
15076
15077
15078
15079
15080
15081
15082
15083
15084
15085
15086
15087
15088
15089
15142
15143
15144
15145
15146
15147
15148
15149
15150

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
10G2,5
12G2,5
14G2,5
16G2,5
18G2,5
20G2,5
25G2,5
30G2,5
34G2,5
36G2,5
42G2,5
50G2,5
3G4
4G4
5G4
4G6
5G6
4G10
5G10
4G16
5G16

Outer
Cop.
approx. mm weight
kg/km
7,7
43,0
8,4
72,0
9,1
96,0
10,2
120,0
12,2
168,0
15,0
240,0
15,2
288,0
16,1
336,0
17,2
384,0
18,1
432,0
19,2
480,0
22,5
600,0
23,5
720,0
25,2
816,0
25,2
864,0
27,4
1008,0
30,0
1200,0
10,4
115,0
11,4
154,0
12,7
192,0
13,3
230,0
14,5
288,0
17,7
384,0
19,7
480,0
20,8
614,0
23,3
768,0

Weight
approx.
kg/km
130,0
160,0
200,0
268,0
357,0
486,0
572,0
612,0
702,0
800,0
920,0
1100,0
1400,0
1500,0
1600,0
1800,0
2100,0
221,0
260,0
318,0
392,0
481,0
642,0
780,0
926,0
1135,0

AWG-No.
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
12
12
12
10
10
8
8
6
6

Dimensions and specifications may be changed without prior notice. (RC01)

To be able to provide information on the service life and in line


with our certication to DIN EN ISO 9001:2000, we document the
realistic testing of our cables suitable for use in drag chains.

C6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 500-PVC

high flexible, safety against high bending in

drag chain systems, oil resistant, low torsion, meter marking




Technical data

Cable structure

Properties

Special drag chain cables for high


mechanical stress in adapted to
DINVDE0281 part13
Temperature range
flexing -5 C to +80 C
fixed installation -30 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors,


Unilay with short pitch length
Special TPE core insulation
Black cores with continuous white
numbering
Green-yellow earth core (3 cores and above)
Stranding:
<7 cores: cores stranded in a layer with
optimal lay-length around a filler as per
construction
7 cores: cores stranded with optimal
lay-length to bunch-construction with low
torsion strength, optimal selected short
lay-length around a filler
Special-PVC outer sheath, especially
resistant against fatigue strength, extruded
as filler with pressure
Sheath colourblack (RAL 9005)
with meter marking, change-over in 2011


PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Low adhesion
ozon- and uv-resistant
High property of alternating bending
strength
High resistant to mechanical strain
Long life durabilities due to low
friction-resistancen
Better chemical resistance
Oil resistance to DIN/ EN 60811-2-1
High stability
Higher economical solution
Reduced , results low weight of moving
materials
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
MULTISPEED 500-C-PVC see page C 10


Application
HELUKABEL MULTISPEED 500-PVC are installed there, where the extreme requirements for the cables are necessary. The selected materials
and lay-up technique permit these high flexible cables for permanent application in drag chains for long distances, high and low speed of
movements.
These high flexible PVC control cables are suitable for shift- and bending stresses in machines and machine tool constructions. These are
installed in dry, moist rooms and in open airwith free movement without tensile stress or forced movements.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
24050
24051
24052
24053
24054
24055
24056
24057
24058
24059
24060
24061
24062
24063
24064
24065
24066
24067

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75
36G0,75
42G0,75
3G1
4G1

Outer
Cop.
approx. mm weight
kg/km
4,3
9,6
4,6
14,4
5,0
19,0
5,4
24,0
8,9
33,6
9,7
58,0
11,8
86,0
13,9
120,0
5,6
29,0
6,3
36,0
10,3
50,0
11,0
86,0
13,9
130,0
15,9
180,0
19,6
259,0
21,5
302,0
5,4
29,0
5,9
38,4

Weight
approx.
kg/km
40,0
45,0
57,0
66,0
81,0
133,0
194,0
274,0
63,0
79,0
107,0
169,0
247,0
366,0
540,0
630,0
69,0
86,0

AWG-No.
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
17
17


Part no.
24068
24069
24070
24071
24072
24073
24074
24075
24076
24077
24078
24079
24080
24081
24082
24083
24084
24085

No.cores x
cross-sec.
mm
5G1
7G1
12G1
18G1
25G1
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5

Outer
Cop.
approx. mm weight
kg/km
6,7
48,0
11,1
67,0
12,0
115,0
14,8
173,0
17,2
240,0
6,4
43,0
7,0
58,0
7,8
72,0
13,0
101,0
14,2
173,0
17,5
259,0
20,1
360,0
8,8
96,0
9,8
120,0
16,1
168,0
17,8
288,0
21,8
432,0
24,4
600,0

Weight
approx.
kg/km
101,0
140,0
227,0
351,0
489,0
88,0
110,0
130,0
182,0
319,0
420,0
604,0
172,0
219,0
303,0
504,0
754,0
940,0

AWG-No.
17
17
17
17
17
16
16
16
16
16
16
16
14
14
14
14
14
14

Dimensions and specifications may be changed without prior notice. (RC01)

C7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-HF-CY

high flexible, screened control cable for drag chains, oil

resistant, EMC-preferred type, meter marking




C


Technical data

Cable structure

Properties

Special PVC control cable, extreme flexibility


due to special construction
Requirements adapted to DINVDE0281
part13
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, extra fine wire conductors,


to DINVDE0295 cl.6 col.4, BS6360 cl.6
and IEC60228 cl.6
Core insulation of special PVC Z7225
Black cores with continuous white figure
imprint to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
selected lay-length
Core wrapping with fleece PVC-inner
sheath
One layer of tinned copper wire screening1),
interworened with synthetic cross-helix to
improve the bending behaviour
Minimum coverage 80%
Special PVC outer sheath, TM5 to
DINVDE0281 part1 and HD21.1
Colour grey (RAL 7001)
with meter marking, change-over in 2011

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
oil resistant to DIN/ EN 60811-2-1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Please note the cleanroom qualification
when ordering.
1)Change-over up to construction with
Cu-screening, tinned, approx. 85% for
coverage optimisation of the useful
properties are in preparation.
unscreened analogue type:
JZ-HF see page C 5

Application
JZ-HF cables are ideal for use in the machine tool industry, in robotics and machine production and anywhere where high flexibility is essential.
These cables have shown excellent performance in combination with standard cable trays.
These cables are suitable for flexible use for medium mechanical stresses with free movements.
The dense screening assures disturbance-free transmission of all signals and impulses. An ideal disturbance-free control cable for the above
application.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
15930
15931
15932
15933
15934
15935
15876
15877
15936
15937
15878
15938
15879
15880
15881
15882
15883

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
14G0,5
16G0,5
18G0,5
20G0,5
21G0,5
25G0,5
30G0,5
34G0,5
36G0,5
42G0,5
50G0,5

Outer
Cop.
approx. mm weight
kg/km
7,2
30,0
7,5
38,0
8,1
48,0
8,6
64,0
9,9
70,0
11,6
100,0
12,2
135,0
13,0
145,0
13,8
154,0
14,3
160,0
14,8
175,0
16,1
240,0
16,6
280,0
17,7
290,0
17,7
300,0
19,2
330,0
21,2
393,0

Weight
approx.
kg/km
90,0
115,0
140,0
168,0
217,0
274,0
332,0
388,0
445,0
497,0
500,0
505,0
515,0
530,0
572,0
605,0
742,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20


Part no.
15945
15946
15947
15948
15949
15885
15950
15886
15887
15951
15888
15889
15952
15890
15891
15892
15893
15894

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
10G0,75
12G0,75
14G0,75
16G0,75
18G0,75
20G0,75
21G0,75
25G0,75
30G0,75
34G0,75
36G0,75
42G0,75
50G0,75

Outer
Cop.
approx. mm weight
kg/km
7,6
39,0
8,1
49,0
8,6
60,0
9,4
70,0
10,5
95,0
12,6
110,0
12,9
140,0
13,4
163,0
14,2
187,0
14,8
211,0
15,5
216,0
16,2
272,0
17,7
322,0
18,2
414,0
19,8
473,0
19,8
500,0
21,0
583,0
23,1
695,0

Weight
approx.
kg/km
105,0
128,0
184,0
200,0
269,0
327,0
366,0
426,0
487,0
547,0
551,0
590,0
600,0
650,0
685,0
720,0
800,0
954,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18

Continuation

C8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-HF-CY

high flexible, screened control cable for drag chains, oil

resistant, EMC-preferred type, meter marking

Part no.
15961
15962
15963
15964
15965
15966
15967
15968
15969
15970
15971
15972
15976
15977
15978
15979
15980
15981
15982
15983
15152
15153
15154

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
12G1
18G1
25G1
34G1
41G1
50G1
65G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
41G1,5
50G1,5
61G1,5

Outer
Cop.
approx. mm weight
kg/km
8,1
50,0
8,4
60,0
9,0
73,0
9,8
81,0
11,2
114,0
13,4
186,0
15,7
254,0
19,0
365,0
21,0
500,0
22,7
576,0
24,5
681,0
27,7
932,0
8,6
64,0
9,0
84,0
9,8
99,0
10,5
120,0
12,5
148,0
14,8
274,0
17,3
386,0
21,0
584,0
24,8
867,0
27,3
970,0
29,8
1028,0

Weight
approx.
kg/km
115,0
142,0
196,0
271,0
307,0
474,0
622,0
828,0
1049,0
1257,0
1437,0
1823,0
170,0
203,0
243,0
288,0
403,0
592,0
844,0
1155,0
1227,0
1445,0
1724,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16


Part no.
15925
15926
15927
15928
15929
15155
15156
15157
15158
15159
15160
15161
15162
15163

No.cores x
cross-sec.
mm
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
3G4
4G4
5G4
4G6
5G6
4G10
5G10
4G16
5G16

Outer
Cop.
approx. mm weight
kg/km
10,8
140,0
11,5
159,0
12,9
194,0
15,1
234,0
18,4
390,0
13,0
178,0
14,2
222,0
15,6
328,0
16,0
305,0
17,5
441,0
21,2
485,0
23,2
610,0
24,1
840,0
27,0
1050,0

Weight
approx.
kg/km
215,0
264,0
344,0
410,0
721,0
292,0
372,0
448,0
526,0
632,0
838,0
998,0
1225,0
1560,0

AWG-No.
14
14
14
14
14
12
12
12
10
10
8
8
6
6

Dimensions and specifications may be changed without prior notice. (RC01)

Terminations and straight-through joints


Telephone calbes
Low voltage
Medium voltage
Accessories

You can nd terminations and straight-through joints in our catalogue Cable Accessories.

C9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 500-C-PVC

high flexible, safety against high bending

in drag chain systems, oil resistant, low torsion, screened, EMC-preferred type, meter marking


C


Technical data

Cable structure

Properties

Special drag chain cables for high


mechanical stress in adapted to
DINVDE0281 part13
Temperature range
flexing -5 C to +80 C
fixed installation -30 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation4x cable
Coupling resistance
max. 250 Ohm x km
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors,


Unilay with short pitch length
Special TPE core insulation
Black cores with continuous white
numbering
Green-yellow earth core (3 cores and above)
Stranding:
<7 cores: cores stranded in a layer with
optimal lay-length around a filler as per
construction
7 cores: cores stranded with optimal
lay-length to bunch-construction with low
torsion strength, optimal selected short
lay-length around a filler
Special-PVC inner sheath YM2 extruded as
filler with pressure grey (RAL 7001)
Tinned copper braidet screen, coverage
85% max., with optimal bunch
Fleece separator, ensure good dismantling
ability
Special-PVC outer sheath, especially
resistant against fatigue strength
Sheath colour black (RAL 9005)
with meter marking, change-over in 2011

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Low adhesion
ozon- and uv- resistant
High property of alternating bending
strength
Long life durability due to low
friction-resistance
Better chemical resistance
Oil resistance to DIN/ EN 60811-2-1
High stability
Higher economical solution
Reduced , results low weight of moving
materials
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
MULTISPEED 500-PVC see page C 7

Application
HELUKABEL MULTISPEED 500-C-PVC are installed there, where the extreme requirements for the cables are necessary. The selected materials
and lay-up technique permit these high flexible cables for permanent application in drag chains for long distances, high and low speed of
movements.
These high flexible PVC control cables are suitable for shift- and bending stresses in machines and machine tool constructions. These are
installed in dry, moist rooms and in open airwith free movement without tensile stress or forced movements.
These screened cables are particularly suitable for the interference-free transmission in instrumentation and control engineering applications.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
24086
24087
24088
24089
24090
24091
24092
24093
24094
24095
24096
24097
24098
24099
24100
24101
24102

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
9G0,5
12G0,5
18G0,5
25G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75

Outer
Cop.
approx. mm weight
kg/km
6,2
30,0
6,7
36,0
7,2
42,0
7,6
48,0
11,4
64,0
11,4
80,0
12,4
105,0
14,7
137,0
17,1
210,0
6,8
40,0
7,3
48,0
7,8
55,0
8,3
66,0
12,7
85,0
13,7
135,0
17,1
190,0
19,5
275,0

Weight
approx.
kg/km
88,0
101,0
116,0
146,0
181,0
219,0
271,0
374,0
542,0
96,0
111,0
140,0
161,0
227,0
317,0
486,0
651,0

AWG-No.
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18


Part no.
24103
24104
24105
24106
24107
24108
24109
24110
24111
24112
24113
24114
24115
24116
24117
24118

No.cores x
cross-sec.
mm
3G1
4G1
5G1
7G1
12G1
18G1
25G1
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
4G2,5
5G2,5

Outer
Cop.
approx. mm weight
kg/km
7,6
59,0
8,1
70,0
8,9
84,0
13,6
106,0
14,6
174,0
18,4
240,0
21,0
332,0
8,4
75,0
9,1
90,0
10,2
108,0
15,7
157,0
17,4
240,0
21,3
355,0
24,3
448,0
11,2
134,0
12,2
175,0

Weight
approx.
kg/km
131,0
164,0
198,0
252,0
410,0
550,0
756,0
166,0
199,0
229,0
304,0
502,0
709,0
939,0
270,0
335,0

AWG-No.
17
17
17
17
17
17
17
16
16
16
16
16
16
16
14
14

Dimensions and specifications may be changed without prior notice. (RC01)

C 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR-JZ-HF
MULTIFLEX 512-PUR
MULTISPEED 500-PUR
PUR-JZ-HF-YCP
MULTIFLEX 512-C-PUR
MULTISPEED 500-C-PUR
MULTISPEED 500-TPE
MULTISPEED 500-C-TPE
Photo: Hller Hille GmbH

PUR Cables for Drag Chains


The machinery and plant industries but especially
the tool making industries are working particularly with mineral oils, alkalis and aggressive collant
emulsions and under difcult working environmental conditions.
Due to these conditions the electrical control
cables, data cables as well as cables for trailing
chains have to perform to exceptionally high
standards. Flexibility, abrasion and oil resistance
have to be guaranteed.

HELUKABEL in co-operation with the leading


machine and plant industries have developed
suitable and application orientated cables.
PUR cables are tested among the others, mineral
and synthetic oils, cutting oils, coolant emulsions, etc. For the operation in power trailing
chains, these cables are tested to multimillion
alternating bending cycles.
Consequently we believe that we can deliver the
right cable for your application needs.

C 11
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR-JZ-HF

high flexible, cable for drag chains, abrasion and coolant

resistant, meter marking




C


Technical data

Cable structure

Properties

Special polyurethane control cable adapted


to DINVDE0281, 0282
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, extra fine wire conductors,


bunch stranded to DINVDE0295 cl.6,
BS6360 cl.6 and IEC60228 cl.6
Oil resistant PVC core insulation TI2, in
adapted to DINVDE0281 part1, for better
sliding abilities
Black cores with continuous white
numbering to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
selected lay-length
Core wrapping with fleece
Special full-polyurethane outer jacket
TMPU, to DINVDE0282 part10, appendixA
Colour grey (RAL7001)
with meter marking, change-over in 2011

Suitable for outdoor lying and resistant to


UV-radiation, oxygen, ozone and hydrolysis.
Conditionally resistant to microbes
Adhesion-low
Flame retardant according to VDE
0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
Cross-linked types also available on request.
screened analogue type:
PUR-JZ-HF-YCP see page C 17

Application
PUR-JZ-HF is an extremely robust cable noted for its good tear and abrasion resistance. Due to its good performance with mineral oils and
especially in connection with coolants, this cable is well suited for use in the machinery, tool making and steel industries in critical areas. Its
high abrasion resistance and good flexing ability make it quick and easy to install and, with its low bending radius, ideal for use with cable
trays.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
15520
15521
15522
15523
15524
16161
15525
15526
15527
15528
15529
15530
15531
15532
15533
15534
15535
15538
15539
15540
15541
15542
15543
15544
15545
15546
15547
15548
15549
15550
15551
15552
15553

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
7x0,5
8G0,5
10G0,5
12G0,5
14G0,5
18G0,5
21G0,5
25G0,5
30G0,5
34G0,5
42G0,5
50G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
8G0,75
10G0,75
12G0,75
14G0,75
18G0,75
21G0,75
25G0,75
30G0,75
34G0,75
42G0,75
50G0,75

Outer
Cop.
approx. mm weight
kg/km
5,5
9,6
6,0
14,4
6,4
19,1
6,9
24,0
7,9
33,6
7,8
33,6
8,6
38,0
9,7
48,0
9,9
58,0
10,4
67,0
11,4
86,4
12,1
96,0
13,5
120,0
14,2
144,0
15,2
163,0
16,2
202,0
18,0
240,0
6,0
14,4
6,3
21,6
6,8
29,0
7,4
36,0
8,7
50,0
9,5
58,0
10,7
72,0
10,9
86,0
11,5
101,0
12,7
130,0
13,4
151,0
15,0
180,0
15,8
216,0
17,2
245,0
18,5
302,0
20,1
360,0

Weight
approx.
kg/km
45,0
56,0
69,0
92,0
126,0
126,0
136,0
158,0
176,0
212,0
283,0
310,0
330,0
390,0
420,0
500,0
580,0
57,0
72,0
97,0
119,0
165,0
189,0
214,0
247,0
283,0
356,0
502,0
698,0
720,0
770,0
840,0
990,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18


Part no.
15556
15557
15558
15559
15560
15561
15562
15563
15564
15565
15566
15567
15568
15569
15570
15571
15572
15573
15575
15576
15577
15578
15579
15580
15581
15582
15583
15584
15585
15586
15587
15588
15589

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
8G1
10G1
12G1
14G1
18G1
21G1
25G1
32G1
34G1
41G1
42G1
50G1
65G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5
14G1,5
18G1,5
21G1,5
25G1,5
30G1,5
34G1,5
42G1,5

Outer
Cop.
approx. mm weight
kg/km
6,3
19,2
6,6
29,0
7,1
38,5
7,8
48,0
9,0
67,0
9,9
77,0
11,1
96,0
11,1
115,0
12,1
134,0
13,6
173,0
14,2
196,0
16,1
240,0
17,6
308,0
18,4
326,0
19,7
394,0
19,7
403,0
21,7
480,0
30,9
624,0
6,8
29,0
7,2
43,0
7,7
58,0
8,6
72,0
10,3
101,0
11,0
115,0
12,7
144,0
12,7
173,0
13,4
202,0
15,1
259,0
16,2
302,0
18,0
360,0
18,7
410,0
20,6
490,0
22,4
605,0

Weight
approx.
kg/km
64,0
83,0
113,0
137,0
191,0
218,0
251,0
294,0
337,0
420,0
504,0
600,0
732,0
776,0
925,0
949,0
1092,0
1400,0
90,0
117,0
147,0
181,0
274,0
313,0
344,0
391,0
457,0
589,0
680,0
801,0
938,0
1048,0
1290,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

Continuation

C 12
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR-JZ-HF

high flexible, cable for drag chains, abrasion and coolant

resistant, meter marking




Part no.
15590
15591
15592
15620
15621
15622
15623
15624
15625
15626
15627
15628
15630
15631
15632
15633
15634
15653
15636

No.cores x
cross-sec.
mm
50G1,5
61G1,5
65G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
14G2,5
18G2,5
25G2,5
2x4
3G4
4G4
5G4
7G4
1G6
3G6

Outer
Cop.
approx. mm weight
kg/km
24,2
720,0
32,4
889,0
33,6
940,0
8,5
48,0
9,0
72,0
9,9
96,0
11,0
120,0
12,8
168,0
16,2
288,0
17,1
336,0
19,1
432,0
22,8
600,0
10,1
77,0
10,9
115,0
12,0
154,0
13,4
192,0
16,0
269,0
7,3
58,0
12,8
173,0

Weight
approx.
kg/km
1520,0
1850,0
1970,0
128,0
160,0
200,0
268,0
357,0
571,0
612,0
800,0
1100,0
190,0
250,0
320,0
400,0
550,0
81,0
350,0

AWG-No.
16
16
16
14
14
14
14
14
14
14
14
14
12
12
12
12
12
10
10


Part no.
15637
15638
15639
15654
15641
15642
15643
15644
15655
15645
15646
15647
15656
15648
15649
15650
15651
15652

No.cores x
cross-sec.
mm
4G6
5G6
7G6
1G10
3G10
4G10
5G10
7G10
1G16
4G16
5G16
7G16
1G25
4G25
4G35
4G50
4G70
4G95

Outer
Cop.
approx. mm weight
kg/km
13,9
230,0
15,4
288,0
18,0
403,0
8,9
96,0
16,2
288,0
18,1
384,0
20,3
480,0
24,3
672,0
10,0
154,0
21,1
614,0
23,5
768,0
28,7
1075,0
11,1
240,0
34,0
960,0
37,0
1344,0
44,0
1920,0
53,0
2688,0
59,0
3648,0

Weight
approx.
kg/km
500,0
580,0
800,0
152,0
660,0
750,0
990,0
1300,0
215,0
1200,0
1500,0
1900,0
320,0
1700,0
2300,0
2500,0
4600,0
6400,0

AWG-No.
10
10
10
8
8
8
8
8
6
6
6
6
4
4
2
1
2/0
3/0

Dimensions and specifications may be changed without prior notice. (RC02)

Bundling, binding, fastening


Plastic helix
Cable tie
Hook and loop cable tie
Mounting block

You can nd bundling, binding, fastening in our catalogue Cable Accessories.

C 13
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTIFLEX 512-PUR

special cable for drag chains,

halogen-free, meter marking




C


Technical data

Cable structure

Properties

Special drag chain cables for high


mechanical stress, adapted to DINVDE0282
part1 and part10
Temperature range
flexing -40 C to +80 C
fixed installation -50 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage
3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing 5x cable
fixed installation 3x cable
Alternating bending cycles
approx. 10 million
Radiation resistance
up to 50x106 cJ/kg (up to 50 Mrad)

Bare copper, extra fine wire conductors,


bunch stranded to DINVDE0295 cl.6,
col.4, BS6360 cl.6 and IEC60228 cl.6
Special core insulation, modified TPE
Black cores with continuous white
numbering
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
selected lay-length
Special core wrapping over each layer (up
to 4 mm without core wrapping over the
outer layer)
Special full-polyurethane outer jacket
TMPU, to DINVDE0282 part10
Colour grey (RAL7001) outer surface mat
with meter marking, change-over in 2011

Very good oil resistant


Guaranteed permanent application in
multi-shift operation under extreme high
bending stress
Adhesion-low
High resistant to mechanical strain
High property of alternating bending
strength
Long life durabilities through low
friction-resistance by using the TPE
insulation
High tensile strength-, abrasion- and
impact resistant at low temperature
Resistant to Weather, Ozone and
UV-radiation, Solvents, acids and alkalis,
Hydraulic liquidity and Hydrolysis
PUR-jacket flame retardant according to
VDE0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
when ordering.
screened analogue type:
MULTIFLEX 512-C-PUR see page C 19

Application
The special cables for drag chains are used for permanent flexible applications in machineries, machine tools, robot technics, for movable
automated machinery parts and multi-shift operation. Those cables are developed according to the newest state of technology improvement.
These high flexible control cables with sliding abilities guaranteed an optimum service life durabilities and also very economic by using the
TPE-core insulation and the PUR-outer jacket. The PUR material is adhesion-low and cut-resistant.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
22501
22502
22503
22504
22505
22506
22507
22508
22509
22510
22511

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
20G0,5
25G0,5
30G0,5
36G0,5

Outer
Cop.
approx. mm weight
kg/km
5,5
9,6
5,8
14,4
6,4
19,0
7,0
24,0
8,1
33,6
9,9
58,0
11,5
86,0
12,0
96,0
13,7
120,0
14,3
144,0
15,3
172,0

Weight
approx.
kg/km
38,0
46,0
59,0
68,0
88,0
131,0
197,0
260,0
282,0
315,0
374,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20


Part no.
22512
22513
22514
22515
22516
22517
22518
22519
22520
22521
22522

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
20G0,75
25G0,75
30G0,75
36G0,75

Outer
Cop.
approx. mm weight
kg/km
6,2
14,4
6,5
21,6
7,0
29,0
7,8
36,0
9,0
50,0
11,0
86,0
13,0
130,0
13,5
144,0
15,4
180,0
16,2
216,0
17,6
259,0

Weight
approx.
kg/km
47,0
58,0
69,0
85,0
118,0
183,0
270,0
290,0
374,0
420,0
498,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18

Continuation

C 14
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTIFLEX 512-PUR

special cable for drag chains,

halogen-free, meter marking

Part no.
22523
22524
22525
22526
22527
22528
22529
22530
22531
22532
22533
22878
22879
22880
22534
22535
22536
22537
22538
22539
22540
22541
22542
22543
22544
22881
22882
22883

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
12G1
18G1
20G1
25G1
30G1
36G1
41G1
50G1
65G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
20G1,5
25G1,5
30G1,5
36G1,5
42G1,5
50G1,5
61G1,5

Outer
Cop.
approx. mm weight
kg/km
6,9
19,2
7,4
29,0
8,0
38,0
8,7
48,0
10,2
67,0
12,6
115,0
14,8
173,0
15,8
192,0
18,1
240,0
18,5
288,0
20,1
346,0
22,0
410,0
24,0
498,0
27,2
650,0
7,6
29,0
8,1
43,0
8,7
58,0
9,7
72,0
11,3
101,0
13,8
173,0
16,3
259,0
17,3
288,0
19,8
360,0
20,3
432,0
22,2
518,0
24,0
628,0
26,2
749,0
28,9
912,0

Weight
approx.
kg/km
55,0
70,0
86,0
102,0
143,0
225,0
334,0
370,0
460,0
530,0
625,0
779,0
953,0
1205,0
70,0
90,0
106,0
145,0
205,0
320,0
465,0
510,0
650,0
750,0
880,0
1209,0
1449,0
1712,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16


Part no.
22545
22546
22547
22548
22549
22550
22551
22552
22553
22554
22555
22556
22557
22558
22559
22560
22561
22562
22563
22564
22565

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
20G2,5
25G2,5
4G4
5G4
7G4
4G6
5G6
7G6
4G10
5G10
7G10
4G16
5G16
7G16

Outer
Cop.
approx. mm weight
kg/km
9,2
48,0
9,7
72,0
10,5
96,0
11,6
120,0
13,8
168,0
16,9
288,0
20,0
432,0
21,2
480,0
24,4
600,0
13,2
154,0
14,6
192,0
17,6
269,0
14,4
230,0
15,9
288,0
19,2
403,0
18,4
384,0
20,7
480,0
24,7
672,0
21,3
614,0
23,8
768,0
28,6
1075,0

Weight
approx.
kg/km
115,0
162,0
196,0
230,0
312,0
532,0
762,0
858,0
998,0
283,0
349,0
498,0
432,0
529,0
782,0
685,0
817,0
1023,0
1042,0
1292,0
1709,0

AWG-No.
14
14
14
14
14
14
14
14
14
12
12
12
10
10
10
8
8
8
6
6
6

Dimensions and specifications may be changed without prior notice. (RC02)

To be able to provide information on the service life and in line


with our certication to DIN EN ISO 9001:2000, we document the
realistic testing of our cables suitable for use in drag chains.

C 15
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 500-PUR

safety against high bending in drag chain

systems, low torsion, halogen-free, meter marking




C


Technical data

Cable structure

Properties

Special drag chain cables for high


mechanical stress in adapted to
DINVDE0281 part13, DINVDE0282 part10
Temperature range
flexing -30 C to +80 C
fixed installation -50 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors,


Unilay with short pitch length
Special TPE core insulation
Black cores with continuous white
numbering
Green-yellow earth core (3 cores and above)
Stranding:
<7 cores: cores stranded in a layer with
optimal lay-length around a filler as per
construction
7 cores: cores stranded with optimal
lay-length to bunch-construction with low
torsion strength, optimal selected short
lay-length around a filler
Special-PUR outer sheath, especially
resistant against fatigue strength, extruded
as filler with pressure
Sheath colour black (RAL 9005)
with meter marking, change-over in 2011

PUR-jacket flame retardant according to


VDE 0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Low adhesion
Halogen-free
Oil resistance
Better chemical resistance
UV and ozone resistance
Higher economical solution
Reduced , results low weight of moving
materials
High property of alternating bending
strength
High resistant to mechanical strain
Long life durabilitys due to low
friction-resistance
High tensile strength, abrasion- and impact
resistance at low temperature
Tear resistance and high stability
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
screened analogue type:
MULTISPEED 500-C-PUR
see page C 21

Application

For permanent application in drag chains for long distances, high and low speed of movements. These cables are installed in dry, moist and
wet rooms and in open air with free movement without tensile stress or forced movements. These robust and abrasion resistant special
control cables are installed there, where the problems appear for the application in permanent stresses e.g. in energy drag chains, industry
robotics, production lines, automatic control systems and permanent movable machinery parts for multi-shift operation. These cables are
installed everywhere, where high requirements for the flexibility, abrasion, oxygen and chemical resistance are necessary.
For applications which go beyond standard solutions we recommend for our especially developed enquiry sheet for energy guiding systems.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
24119
24120
24121
24122
24123
24124
24125
24126
24127
24128
24129
24130
24131
24132
24133
24134
24135
24136
24137

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75
36G0,75
42G0,75
3G1
4G1

Outer
Cop.
approx. mm weight
kg/km
4,3
9,6
4,6
14,4
5,0
19,0
5,4
24,0
8,9
33,6
9,7
58,0
11,8
86,0
13,9
120,0
5,2
21,6
5,6
29,0
6,3
36,0
10,3
50,0
11,0
86,0
13,9
130,0
15,9
180,0
19,6
260,0
21,5
302,0
5,4
29,0
5,9
38,0

Weight
approx.
kg/km
41,0
48,0
62,0
70,0
88,0
131,0
204,0
266,0
51,0
68,0
73,0
92,0
170,0
257,0
280,0
411,0
608,0
59,0
71,0

AWG-No.
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
17
17


Part no.
24138
24139
24140
24141
24142
24143
24144
24145
24146
24147
24148
24149
24150
24151
24152
24153
24154
24155

No.cores x
cross-sec.
mm
5G1
7G1
12G1
18G1
25G1
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5

Outer
Cop.
approx. mm weight
kg/km
6,7
48,0
11,1
67,0
12,0
115,0
14,8
173,0
17,2
240,0
6,4
43,0
7,0
58,0
7,8
72,0
13,0
101,0
14,2
173,0
17,5
259,0
20,1
360,0
8,8
86,0
9,8
120,0
16,1
168,0
17,8
288,0
21,8
432,0
24,4
600,0

Weight
approx.
kg/km
84,0
111,0
200,0
286,0
370,0
81,0
102,0
121,0
164,0
293,0
450,0
631,0
173,0
220,0
290,0
504,0
719,0
940,0

AWG-No.
17
17
17
17
17
16
16
16
16
16
16
16
14
14
14
14
14
14

Dimensions and specifications may be changed without prior notice. (RC02)

C 16
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR-JZ-HF-YCP

EMC-preferred type, cable for drag chains, screened,

PUR-outer sheath, meter marking




Technical data

Cable structure

Properties

Special polyurethane control cable adapted


to DINVDE0281, 0282
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, extra fine wire conductors,


bunch stranded to DINVDE0295 cl.6,
col.4, BS6360 cl.6 and IEC60228 cl.6
Oil resistant PVC core insulation TI2, in
adapted to DINVDE0281 part1, for better
sliding abilities
Black cores with continuous white
numbering to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
selected lay-length
Fleece separator
Oil resistant PVC inner jacket
One layer of tinned copper wire screening,
approx. 85% coverage
Special full-polyurethane outer jacket,
to DINVDE0282 part10, appendixA
Colour grey (RAL7001)
with meter marking, change-over in 2011

Suitable for outdoor lying and resistant to


UV-radiation, oxygen, ozone and hydrolysis.
Conditionally resistant to microbes
Adhesion-low
Flame retardant according to VDE
0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
PUR-JZ-HF see page C 12

Application
PUR-JZ-YCP is a highly robust and tare and abrasion resistant cable with excellent resistance properties to mineral oils and cooling fluids,
thus making it an ideal choice for installation in most types of industrial machinery as well as in steel works and rolling mills, etc. in fact,
wherever you may need a cable to cope with especially critical situations. Easy to install, thanks to its high degree of flexibility. Its high
abrasion resistance and good flexing ability make it quick and easy to install and, with its low bending radius, ideal for use with cable trays.
This screened cable is ideal for use in data signal transmission free from interferences for measurement and control engineering technology.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
22400
22401
22402
22403
22404
22405
22406
22407
22408
22409
22410
22411
22412
22413
22414
22415
22416

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
8G0,5
10G0,5
12G0,5
14G0,5
18G0,5
21G0,5
25G0,5
30G0,5
34G0,5
42G0,5
50G0,5
61G0,5

Outer
Cop.
approx. mm weight
kg/km
7,5
30,0
7,8
38,0
7,8
48,0
8,5
65,0
9,5
70,0
10,4
81,0
11,4
94,0
11,6
110,0
12,0
135,0
13,4
157,0
14,8
175,0
16,1
240,0
16,4
275,0
17,8
305,0
19,1
330,0
20,6
393,0
23,0
541,0

Weight
approx.
kg/km
90,0
104,0
123,0
131,0
172,0
195,0
230,0
250,0
280,0
321,0
380,0
445,0
509,0
560,0
780,0
960,0
1050,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20


Part no.
22417
22418
22419
22420
22421
22422
22423
22424
22425
22426
22427
22428
22429
22430
22431
22432
22433

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
8G0,75
10G0,75
12G0,75
14G0,75
18G0,75
21G0,75
25G0,75
30G0,75
34G0,75
42G0,75
50G0,75
61G0,75

Outer
Cop.
approx. mm weight
kg/km
7,5
39,0
7,8
49,0
8,5
60,0
9,1
70,0
10,9
95,0
11,5
104,0
13,0
110,0
13,2
141,0
13,7
163,0
15,2
211,0
16,4
274,0
18,2
322,0
18,6
414,0
20,0
473,0
21,5
583,0
23,7
626,0
25,9
763,0

Weight
approx.
kg/km
106,0
120,0
150,0
158,0
205,0
272,0
290,0
304,0
380,0
418,0
485,0
578,0
630,0
720,0
780,0
954,0
1085,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18

Continuation

C 17
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR-JZ-HF-YCP

EMC-preferred type, cable for drag chains, screened,

PUR-outer sheath, meter marking

Part no.
22434
22435
22436
22437
22438
22439
22440
22441
22442
22443
22444
22445
22446
22447
22448
22449
22450
22451
22452
22453
22454
22455
22456
22457
22458
22459
22460
22461
22462
22463
22464
22465
22466
22467
22468
22469

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
8G1
10G1
12G1
14G1
18G1
21G1
25G1
32G1
34G1
41G1
42G1
50G1
65G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5
14G1,5
18G1,5
21G1,5
25G1,5
30G1,5
34G1,5
42G1,5
50G1,5
61G1,5
65G1,5

Outer
Cop.
approx. mm weight
kg/km
8,5
50,0
8,8
60,0
9,4
73,0
10,7
81,0
12,1
114,0
13,2
130,0
14,6
178,0
14,8
186,0
15,6
231,0
17,0
254,0
19,0
328,0
20,9
378,0
22,6
450,0
23,3
478,0
25,1
576,0
25,3
590,0
27,6
702,0
30,7
913,0
9,0
64,0
9,4
84,0
10,6
99,0
11,4
120,0
13,3
148,0
14,5
191,0
15,9
240,0
16,1
274,0
16,7
340,0
18,4
395,0
20,6
461,0
22,8
533,0
23,5
608,0
26,1
702,0
27,8
867,0
30,3
1033,0
32,7
1233,0
33,5
1315,0

Weight
approx.
kg/km
116,0
135,0
178,0
188,0
235,0
270,0
340,0
358,0
415,0
500,0
525,0
678,0
777,0
825,0
980,0
998,0
1160,0
1670,0
141,0
164,0
220,0
233,0
323,0
369,0
461,0
481,0
561,0
672,0
780,0
927,0
1030,0
1180,0
1458,0
1857,0
2250,0
2401,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16


Part no.
22470
22471
22472
22473
22474
22475
22476
22477
22478
22479
22480
22481
22482
22483
22484
22485
22486
22487
22488
22489
22490
22491
22492
22493
22494

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
14G2,5
18G2,5
25G2,5
2G4
3G4
4G4
5G4
7G4
3G6
4G6
5G6
7G6
3G10
4G10
5G10
7G10
4G16
5G16
7G16

Outer
Cop.
approx. mm weight
kg/km
10,9
96,0
11,4
150,0
12,2
159,0
13,5
195,0
16,0
240,0
19,4
390,0
20,4
480,0
23,0
620,0
27,7
821,0
13,1
135,0
13,7
178,0
15,6
222,0
16,7
328,0
19,7
360,0
16,0
250,0
17,2
305,0
19,3
441,0
21,6
505,0
20,4
370,0
23,0
485,0
25,3
610,0
28,0
820,0
26,2
840,0
28,6
1050,0
31,5
1510,0

Weight
approx.
kg/km
185,0
278,0
370,0
412,0
470,0
738,0
870,0
1100,0
1512,0
235,0
350,0
460,0
550,0
700,0
525,0
700,0
800,0
1100,0
855,0
1140,0
1310,0
1630,0
1391,0
1810,0
2166,0

AWG-No.
14
14
14
14
14
14
14
14
14
12
12
12
12
12
10
10
10
10
8
8
8
8
6
6
6

Dimensions and specifications may be changed without prior notice. (RC02)

C 18
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTIFLEX 512-C-PUR

special cable for drag chains,

halogen-free, screened, EMC-preferred type, meter marking




Technical data

Cable structure

Properties

Special drag chain cables for extreme


mechanical stressesinaccordance to
DINVDE0282 part1 and part10
Temperature range
flexing -40 C to +80 C
fixed installation -50 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage
3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Test of alternating bending cycles
approx. 10 million
Radiation resistance
up to 50x106 cJ/kg (up to 50 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, extra fine wire conductors,


bunch stranded to DINVDE0295 cl.6,
col.4, BS6360 cl.6 and IEC60228 cl.6
Special core insulation, modified TPE
Black cores with continuous white
numbering
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
selected lay-length
Special core wrapping over each layers and
an additional fleece over outer layer
TPE-inner sheath, halogen-free
Wrapping with special tapes
Tinned copper braided screening , approx.
85% coverage
Special core wrapping of fleece (up to
4mm without core wrapping over the
outer layer
Special full-polyurethane outer jacket
TMPU, to DINVDE0282 part10, appendixA
Jacket colour grey,(RAL 7001), with a matte
surface
with meter marking, change-over in 2011

Very good oil resistant


Guaranteed permanent application in
multi-shift operation under extreme high
bending stress
Adhesion-low
High resistant to mechanical strain
High property of alternating bending
strengthLong life durabilities through low
friction-resistance by using the TPE
insulation
High tensile strength-, abrasion- and
impact resistant at low temperature
Resistant to Weather, Ozone and
UV-radiation, Solvents, acids and alkalis,
Hydraulic liquidity and Hydrolysis
PUR-jacket flame retardant according to
VDE 0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
Please note the cleanroom qualification
when ordering.
For more information see introduction
unscreened analogue type:
MULTIFLEX 512-PUR see page C 14


Application
The special screened cables for drag chains are mainly applied for impulse transmission to prevent external interference effects and used
for permanent flexible applications in machineries, machine tools, robot technics, for movable automated machinery parts and multi-shift
operation. Those cables are developed according to the newest state of technology improvement. These high flexible control cables with
sliding abilities guaranteed an optimum service life durabilities and also very economic by using the TPE-core insulation and the PUR-outer
jacket which is adhesive-free and cut-resistant.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
22571
22572
22573
22574
22575
22576

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5

Outer
Cop.
approx. mm weight
kg/km
8,3
30,0
8,5
38,0
9,0
50,0
9,7
65,0
11,1
70,0
12,7
100,0

Weight
approx.
kg/km
90,0
105,0
124,0
132,0
175,0
250,0

AWG-No.
20
20
20
20
20
20


Part no.
22577
22578
22579
22580
22581

No.cores x
cross-sec.
mm
18G0,5
20G0,5
25G0,5
30G0,5
36G0,5

Outer
Cop.
approx. mm weight
kg/km
14,7
157,0
15,4
167,0
17,1
240,0
17,9
273,0
19,2
306,0

Weight
approx.
kg/km
325,0
350,0
450,0
510,0
580,0

AWG-No.
20
20
20
20
20

Continuation

C 19
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTIFLEX 512-C-PUR

special cable for drag chains,

halogen-free, screened, EMC-preferred type, meter marking

Part no.
22582
22583
22584
22585
22586
22587
22588
22589
22590
22591
22592
22593
22594
22595
22596
22597
22598
22599
22600
22601
22602
22603
22884
22885
22886
22604
22605
22606
22607
22608

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
20G0,75
25G0,75
30G0,75
36G0,75
2x1
3G1
4G1
5G1
7G1
12G1
18G1
20G1
25G1
30G1
36G1
41G1
50G1
65G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5

Outer
Cop.
approx. mm weight
kg/km
8,8
39,0
9,3
49,0
9,7
60,0
10,5
70,0
11,9
95,0
14,2
140,0
16,3
220,0
16,9
249,0
19,2
313,0
19,7
470,0
21,2
500,0
9,7
50,0
10,0
60,0
10,8
73,0
11,7
81,0
13,4
114,0
16,0
186,0
18,5
254,0
19,4
322,0
21,7
377,0
22,5
429,0
24,3
516,0
26,1
610,0
28,4
690,0
32,2
852,0
10,2
64,0
11,0
84,0
11,6
99,0
12,6
129,0
14,5
148,0

Weight
approx.
kg/km
110,0
120,0
148,0
160,0
205,0
308,0
420,0
450,0
579,0
630,0
745,0
120,0
135,0
173,0
187,0
240,0
360,0
498,0
568,0
670,0
774,0
895,0
1032,0
1160,0
1660,0
145,0
168,0
217,0
235,0
325,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16

Part no.
22609
22610
22611
22612
22613
22887
22888
22889
22614
22615
22616
22617
22618
22619
22620
22621
22622
22623
22624
22625
22626
22627
22628
22629
22630
22631
22632
22633
22634

No.cores x
cross-sec.
mm
12G1,5
18G1,5
25G1,5
30G1,5
36G1,5
42G1,5
50G1,5
61G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
20G2,5
25G2,5
4G4
5G4
7G4
4G6
5G6
7G6
4G10
5G10
7G10
4G16
5G16
7G16

Outer
Cop.
approx. mm weight
kg/km
17,4
279,0
19,9
393,0
23,7
584,0
24,6
607,0
26,4
702,0
28,4
829,0
31,2
1025,0
34,2
1190,0
11,9
104,0
12,6
140,0
13,6
164,0
14,7
190,0
17,4
236,0
20,9
390,0
24,2
607,0
25,6
661,0
29,1
796,0
16,8
222,0
18,4
328,0
21,6
360,0
18,1
305,0
19,6
441,0
23,2
505,0
22,5
485,0
24,7
610,0
29,3
820,0
25,7
840,0
28,2
1050,0
33,6
1510,0

Weight
approx.
kg/km
481,0
675,0
927,0
1025,0
1210,0
1441,0
1709,0
2025,0
198,0
284,0
378,0
423,0
486,0
756,0
1127,0
1210,0
1530,0
448,0
533,0
678,0
636,0
772,0
1028,0
1052,0
1096,0
1530,0
1386,0
1759,0
2087,0

AWG-No.
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14
14
12
12
12
10
10
10
8
8
8
6
6
6

Dimensions and specifications may be changed without prior notice. (RC02)

C 20
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 500-C-PUR

safety against high bending in drag chain

systems, low torsion, halogen-free, EMC-preferred type, halogen-free, meter marking




Technical data

Cable structure

Properties

Special drag chain cables for high


mechanical stress in adapted to
DINVDE0281 part 3, DINVDE0282 part10
and DINVDE0245
Temperature range
flexing -30 C to +80 C
fixed installation -50 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Coupling resistant
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors,


Unilay with short pitch length
Special TPE core insulation
Black cores with continuous white
numbering
Green-yellow earth core (3 cores and above)
Stranding:
<7 cores: cores stranded in a layer with
optimal lay-length around a filler as per
construction
7 cores: cores stranded with optimal
lay-length to bunch-construction with low
torsion strength, optimal selected short
lay-length around a filler
Special-TPE inner sheath, extruded as filler
with pressure, grey RAL7001
Tinned copper braided screen, coverage
85% max., with optimal pitch
Fleece separator, ensure good dismantling
ability
Special-PUR outer sheath
Sheath colourblack (RAL9005)
with meter marking, change-over in 2011

PUR-jacket flame retardant according to


VDE 0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Low adhesion
High property of alternating bending
strength
High resistant to mechanical strain
Long life durabilitys due to low
friction-resistance
High tensile strength, abrasion- and impact
resistance at low temperature
Tear resistance
High stability and oil resistance
Better chemical resistance
UV and ozone resistance
Higher economical solution
Reduced , results low weight of moving
materials
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers.


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
unscreened analogue type:
MULTISPEED 500-PUR see page C 16

Application
For permanent application in drag chains for long distances, high and low speed of movements. These cables are installed in dry, moist and
wet rooms and in open air with free movement without tensile stress or forced movements. These robust and abrasion resistant special
control cables are installed there, where the problems appear for the application in permanent stresses e.g. in energy drag chains. These
cables are installed everywhere, where high requirements for the flexibility, abrasion, oxygen and chemical resistance are necessary. These
screened cables are particularly suitable for the interference-free transmission in instrumentation and control engineering applications.
For applications which go beyond standard solutions we recommend for our especially developed enquiry sheet for energy guiding systems.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
24156
24157
24158
24159
24160
24161
24162
24163
24164
24165
24166
24167
24168
24169
24170
24171
24172

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
9G0,5
12G0,5
18G0,5
25G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75

Outer
Cop.
approx. mm weight
kg/km
6,4
30,0
6,7
36,0
7,2
42,0
7,6
48,0
11,4
64,0
11,4
80,0
12,4
105,0
14,7
137,0
17,1
210,0
6,8
40,0
7,3
48,0
7,8
55,0
8,3
66,0
12,7
85,0
13,7
135,0
17,1
190,0
19,5
275,0

Weight
approx.
kg/km
90,0
104,0
118,0
148,0
184,0
219,0
276,0
378,0
547,0
100,0
117,0
143,0
167,0
229,0
319,0
492,0
659,0

AWG-No.
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18


Part no.
24173
24174
24175
24176
24177
24178
24179
24180
24181
24182
24183
24184
24185
24186
24187
24188
24189
24190

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
12G1
18G1
25G1
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
4G2,5
5G2,5
7G2,5

Outer
Cop.
approx. mm weight
kg/km
7,1
50,0
7,6
59,0
8,1
70,0
8,9
84,0
13,6
106,0
14,6
174,0
18,4
240,0
21,0
332,0
8,4
75,0
9,1
90,0
10,2
108,0
15,7
157,0
17,4
240,0
21,3
355,0
24,3
448,0
11,2
134,0
12,2
175,0
14,0
229,0

Weight
approx.
kg/km
120,0
140,0
167,0
201,0
256,0
417,0
557,0
766,0
170,0
204,0
236,0
309,0
509,0
718,0
944,0
280,0
346,0
410,0

AWG-No.
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
14
14
14

Dimensions and specifications may be changed without prior notice. (RC02)

C 21
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 500-TPE

high flexible, safety against high bending

in drag chain systems, low torsion, halogen-free, meter marking




C


Technical data

Cable structure

Properties

Special drag chain cables for high


mechanical stress in adapted to
DINVDE0281 part13 and DINVDE0245
Temperature range
flexing -30 C to +80 C
fixed installation -50 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing 5x cable
fixed installation 3x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Tinned copper, fine wire conductors, Unilay


with short pitch length Special TPE core
insulation Black cores with continuous
white numbering Green-yellow earth core
(3 cores and above)
Stranding:
<7 cores: cores stranded in a layer with
optimal lay-length around a filler as per
construction
7 cores: cores stranded with optimal
lay-length to bunch-construction with low
torsion strength, optimal selected short
lay-length around a filler
Special-TPE-O outer sheath, extruded as
filler with pressure
Sheath colour ocean blue (RAL 5020)
with meter marking, change-over in 2011
TPE: The selected tinned copper wire
conductor permits the installation in
aggressive environments as well as
hydrogen sulfide, ammonia and sulfur
dioxide

Microbe-resistance - TPE
Halogen-free
Low adhesion
High property of alternating bending
strength
High resistant to mechanical strain
Long life durabilitys due to low
friction-resistance
High tensile strength, abrasion- and impact
resistance at low temperature
Use in multi-shift operations under
extremely high continuous bending loads
Abrasion resistance
Tear resistance
High stability
Oil resistance
Better chemical resistance
UV and ozone resistance
Higher economical solution
Reduced , results low weight of moving
materials
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
when ordering.
screened analogue type:
MULTISPEED 500-C-TPE see page C 24

Application
For permanent application in drag chains for long distances, high and low speed of movements. These cables are installed in dry, moist and
wet rooms and in open air with free movement without tensile stress or forced movements. These robust and abrasion resistant special
control cables are installed there, where the problems appear for the application in permanent stresses e.g. in energy drag chains, industry
robotics, production lines, automatic control systems and permanent movable machinery parts for multi-shift operation. For applications
which go beyond standard solutions we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
24191
24192
24193
24194
24195
24196
24197
24198

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5

Outer
Cop.
approx. mm weight
kg/km
4,3
9,6
4,6
14,4
5,0
19,0
5,4
24,0
8,9
33,6
9,7
58,0
11,8
86,0
13,9
120,0

Weight
approx.
kg/km
42,0
49,0
63,0
70,0
90,0
134,0
209,0
270,0

AWG-No.
20
20
20
20
20
20
20
20


Part no.
24199
24200
24201
24202
24203
24204
24205
24206
24207
24208

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75
36G0,75
42G0,75

Outer
Cop.
approx. mm weight
kg/km
5,0
14,4
5,2
21,6
5,6
29,0
6,3
36,0
10,3
50,0
11,0
86,0
13,9
130,0
15,9
180,0
19,6
260,0
21,5
302,0

Weight
approx.
kg/km
47,0
55,0
70,0
74,0
95,0
174,0
261,0
290,0
419,0
614,0

AWG-No.
18
18
18
18
18
18
18
18
18
18

Continuation

C 22
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 500-TPE

high flexible, safety against high bending

in drag chain systems, low torsion, halogen-free, meter marking

Part no.
24209
24210
24211
24212
24213
24214
24215
24216
24043
24217
24218
24219
24220
24221
24222
24223

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
12G1
18G1
25G1
41G1
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5

Outer
Cop.
approx. mm weight
kg/km
5,2
19,2
5,4
29,0
5,9
38,0
6,7
48,0
11,1
67,0
12,0
115,0
14,8
173,0
17,2
240,0
22,0
394,0
6,4
43,0
7,0
58,0
7,8
72,0
13,0
101,0
14,2
173,0
17,5
259,0
20,1
360,0

Weight
approx.
kg/km
50,0
60,0
74,0
86,0
114,0
210,0
291,0
380,0
510,0
84,0
108,0
126,0
169,0
299,0
460,0
640,0

AWG-No.
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16

Part no.
24224
24225
24226
24227
24228
24229
24230
24231
24232
24233
24234
24235

No.cores x
cross-sec.
mm
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5
4G4
4G6
5G6
4G10
4G16
4G35

Outer
Cop.
approx. mm weight
kg/km
8,8
96,0
9,8
120,0
16,1
168,0
17,8
288,0
21,8
432,0
24,4
600,0
10,3
154,0
11,9
231,0
13,4
289,0
14,7
387,0
20,0
517,0
24,9
1344,0

Weight
approx.
kg/km
179,0
230,0
294,0
510,0
722,0
950,0
197,0
320,0
394,0
520,0
784,0
1711,0

AWG-No.
14
14
14
14
14
14
12
10
10
8
6
2

Dimensions and specifications may be changed without prior notice. (RC02)

Marking
Marking rings
Cable marker
Indian pen

You can nd marking in our catalogue Cable Accessories.

C 23
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 500-C-TPE

safety against high bending in drag

chain systems, low torsion, halogen-free, EMC-preferred type, meter marking




C


Technical data

Cable structure

Properties

Special drag chain cables for high


mechanical stress in adapted to
DINVDE0281 part13 and EDINVDE0245
Temperature range
flexing -30 C to +80 C
fixed installation -50 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing 5x cable
fixed installation 3x cable
Coupling resistance
max. 250 Ohm x km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Tinned copper, fine wire conductors,


Unilay with short pitch length
Special TPE core insulation
Black cores with continuous white
numbering
Green-yellow earth core (3 cores and above)
Stranding:
<7 cores: cores stranded in a layer with
optimal lay-length around a filler as per
construction
7 cores: cores stranded with optimal
lay-length to bunch-construction with low
torsion strength, optimal selected short
lay-length around a filler
Special-TPE inner sheath, extruded as filler
with pressure, natural colour
Screen of Cu braid tinned, coverage 85%
max., with optimal pitch
Fleece separator, ensure good dismantling
ability
Special-TPE-O outer sheath, extruded as
filler with pressure
Sheath colour ocean blue (RAL 5020)
with meter marking, change-over in 2011
TPE: The selected tinned copper wire
conductor and tinned copper wire braid
permit the installation in aggressive
environments as well as hydrogen sulfide,
ammonia and sulfur dioxide.

Microbe-resistance - TPE
High property of alternating bending
strength
Long life durabilitys due to low
friction-resistance
High tensile strength, abrasion- and impact
resistance at low temperature
Low adhesion, oil resistence
Tear resistance
Better chemical resistance
UV and ozone resistance
Reduced , results low weight of moving
materials
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers.


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
Please note the cleanroom qualification
when ordering.
For more information, see introduction
unscreened analogue type:
MULTISPEED 500-TPE see page C 22

Application
For permanent application in drag chains for long distances, high and low speed of movements. These cables are installed in dry, moist and
wet rooms and in open air with free movement without tensile stress or forced movements. These robust and abrasion resistant special
control cables are installed there, where the problems appear for the application in permanent stresses e.g. in energy drag chains. These
cables are installed everywhere, where high requirements for the flexibility, abrasion, oxygen and chemical resistance are necessary.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
24236
24237
24238
24239
24240
24241
24242
24243
24244
24245
24246
24247
24248
24249
24250
24251
24252
24253
24254

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
10G0,5
12G0,5
18G0,5
25G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75
2x1
3G1

Outer
Cop.
approx. mm weight
kg/km
6,5
30,0
6,7
36,0
7,2
42,0
7,6
48,0
11,4
64,0
11,4
80,0
12,4
105,0
14,7
137,0
17,1
320,0
7,0
40,0
7,3
48,0
7,8
55,0
8,3
66,0
12,7
85,0
13,7
135,0
17,1
190,0
19,5
275,0
7,3
50,0
7,6
59,0

Weight
approx.
kg/km
85,0
99,0
107,0
140,0
176,0
204,0
261,0
360,0
530,0
97,0
110,0
139,0
160,0
219,0
307,0
490,0
640,0
115,0
131,0

AWG-No.
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
17
17


Part no.
24255
24256
24257
24258
24259
24260
24261
24262
24263
24264
24265
24266
24267
24268
24269
24270
24271
24272

No.cores x
cross-sec.
mm
4G1
5G1
7G1
12G1
18G1
25G1
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
4G2,5
5G2,5
7G2,5
12G2,5
4G4

Outer
Cop.
approx. mm weight
kg/km
8,1
70,0
8,9
84,0
13,6
106,0
14,8
174,0
18,4
240,0
21,0
332,0
8,4
75,0
9,2
90,0
10,2
108,0
15,7
157,0
17,4
240,0
21,3
355,0
24,3
448,0
11,2
134,0
12,2
175,0
19,5
229,0
21,7
390,0
13,6
194,0

Weight
approx.
kg/km
160,0
195,0
247,0
411,0
547,0
754,0
160,0
194,0
220,0
294,0
490,0
704,0
930,0
260,0
330,0
406,0
990,0
355,0

AWG-No.
17
17
17
17
17
17
16
16
16
16
16
16
16
14
14
14
14
12

Dimensions and specifications may be changed without prior notice. (RC02)

C 24
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BIOFLEX-500-JZ-HF
BIOFLEX-500-JZ-HF-C
KOMPOSPEED JZ-HF-500
KOMPOSPEED JZ-HF-500-C
SUPERTRONIC-PVC
SUPERTRONIC-C-PVC
SUPERTRONIC-PUR
SUPERTRONIC-C-PUR
SUPER-PAAR-TRONIC-C-PUR
Photo: FUCHS DEA SCHMIERSTOFFE GMBH & Co. KG

Bio-Oil and microbial resistant Cables for Drag Chains


We have joined forces with large scale farmers
and operators of biofuel plants to develop a
tailor-made product the new BIOFLEX-500.

wires from HELUKABEL. Specially modied


polymers are used here for the core insulation
and the jacket materials.

HELUKABEL has accordingly matched and extended the range of products from its plant in
Windsbach. Special control cables and wires have
been developed which are not only friendly on
the environment, abrasion-resistant and can be
recycled, they are also resistant to bio-oils. These
are the special BIOFLEX-500-control cables and

In the laboratory, these special compounds have


been subjected to extreme testing according to
VDMA requirements and VDE specications. The
suitability of these compounds has been assessed
by endurance testing to demonstrate the longterm resistance to bio-oils.

C 25
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BIOFLEX-500-JZ-HF

Bio-fuel resistant, abrasion resistant, recyclable

environment friendly, bio-oil resistant1), cable for drag chains, meter marking


C


Technical data

Cable structure

Bio-oil resistant, abrasion resistant special


high flexible control cable in adapted to
DINVDE0245,0281
Temperature range
flexing -20 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 10x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, extra fine wire conductors,


bunch stranded to DINVDE0295 cl.6,
BS6360 cl.6 and IEC60228 cl.6
Special polymer core insulation, for better
sliding abilities
Black cores with continuous white figure
imprint to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
selected lay-length
Core wrapping with fleece
Special outher sheath, polymer compound
Colour dark green
with meter marking, change-over in 2011

Properties

Resistant to
Bio-fuel (diesel and petrol), highly resistant
to biologically decomposable oils, Oxygene,
Ozone, Hydrolysis and Microbes
Low adhesion


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
BIOFLEX-500-JZ-HF-C see page C 27

Application
HELUKABEL BIOFLEX-HF-500 is an extremely robust and high flexible control cable with high abrasion and tear resistant properties. Due to
its high resistance to Bio-fuel, Bio-oil and coolant emulsions. It is especially suited for use in the machine, tool making and plant industries
as well as in the steel industry for difficult and problem areas. Suitable in combination with cable trays in dry, moist and wet rooms and
outdoor installation. The high flexibility of this cable type makes it quick and easy to install. Suitable for outdoor lying. ) For the critical
applications we advise for consultation. For applications which go beyond standard solutions we recommend for our especially developed
enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
25761
25762
25763
25764
25765
25766
25767
25768
25769
25770
25771
25772
25773
25774
25775
25776
25777
25778
25779
25780
25781
25782
25783
25784
25785
25786
25787
25788
25789
25790
25791
25792
25793
25794
25795

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
10G0,5
12G0,5
14G0,5
18G0,5
25G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
10G0,75
12G0,75
14G0,75
18G0,75
25G0,75
2x1
3G1
4G1
5G1
7G1
10G1
12G1
14G1
18G1
25G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5

Outer
Cop.
approx. mm weight
kg/km
5,4
9,6
5,9
14,4
6,3
19,1
6,9
24,0
7,8
33,6
9,6
48,0
10,3
58,0
10,3
67,0
11,5
86,4
13,6
120,0
5,9
14,4
6,2
21,6
6,7
29,0
7,3
36,0
8,7
50,0
10,5
72,0
11,0
86,0
11,4
101,0
12,6
130,0
15,2
180,0
6,6
19,0
7,0
29,0
7,6
38,5
8,2
48,0
9,6
67,0
11,6
96,0
12,0
115,0
13,0
134,0
14,5
173,0
17,6
240,0
7,1
29,0
7,5
43,0
8,2
58,0
9,0
72,0
10,8
101,0

Weight
approx.
kg/km
45,0
56,0
69,0
92,0
126,0
158,0
176,0
212,0
283,0
330,0
57,0
72,0
97,0
119,0
165,0
214,0
247,0
283,0
356,0
698,0
64,0
83,0
113,0
137,0
191,0
251,0
294,0
337,0
420,0
600,0
90,0
117,0
147,0
181,0
274,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16


Part no.
25796
25797
25798
25799
25800
25801
25802
25803
25804
25805
25806
25807
25808
25809
25810
25811
25812
25813
25814
25815
25816
25817
25818
25819
25820
25821
25822
25823
25824
25825

No.cores x
cross-sec.
mm
10G1,5
12G1,5
14G1,5
18G1,5
25G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
14G2,5
18G2,5
25G2,5
2x4
3G4
4G4
5G4
3G6
4G6
5G6
3G10
4G10
5G10
4G16
4G25
4G35
4G50
4G70
4G95

Outer
Cop.
approx. mm weight
kg/km
13,4
144,0
13,4
173,0
14,3
202,0
16,0
259,0
19,5
360,0
8,6
48,0
9,3
72,0
10,3
96,0
11,5
120,0
13,4
168,0
17,0
288,0
18,5
336,0
20,0
432,0
29,6
600,0
10,4
77,0
11,2
115,0
12,5
154,0
13,8
192,0
13,0
173,0
14,7
230,0
16,0
288,0
17,4
288,0
19,0
384,0
21,3
480,0
23,2
614,0
34,0
960,0
37,0
1344,0
44,0
1920,0
53,0
2688,0
59,0
3648,0

Weight
approx.
kg/km
344,0
391,0
457,0
589,0
801,0
128,0
160,0
200,0
268,0
357,0
571,0
612,0
800,0
1100,0
190,0
250,0
320,0
400,0
350,0
500,0
580,0
660,0
750,0
990,0
1200,0
1700,0
2300,0
2500,0
4600,0
6400,0

AWG-No.
16
16
16
16
16
14
14
14
14
14
14
14
14
14
12
12
12
12
10
10
10
8
8
8
6
4
2
1
2/0
3/0

Dimensions and specifications may be changed without prior notice. (RC03)

C 26
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BIOFLEX-500-JZ-HF-C Biofuel-resistant, abrasion-resistant, recyclable,


environmentally friendly, drag-chain cable, bio-oil resistant 1), meter marking


Technical data

Cable structure

Bio-oil resistant, abrasion resistant special


high flexible control cable in adapted to
DINVDE0245,0281
Temperature range
flexing -20 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 15x cable
fixed installation 4x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, extra fine wire conductors,


bunch stranded to DINVDE0295 cl.6,
BS6360 cl.6 and IEC60228 cl.6
Special polymer core insulation, for better
sliding abilities
Black cores with continuous white figure
imprint to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
selected lay-length
Core wrapping with fleece
Special inner sheath
Copper braided screening approx. 85%
coverage
Fleece separator, ensure good dismantling
ability
Special outer sheath polymer compound
Colour dark green
with meter marking, change-over in 2011


Properties

Resistant to
Bio-fuel (diesel and petrol), highly resistant
to biologically decomposable oils, Oxygene,
Ozone, Hydrolysis and Microbes
Low adhesion


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
BIOFLEX-500-JZ-HF see page C 26

Application
HELUKABEL BIOFLEX-HF-500-C is an extremely robust and high flexible control cable with high abrasion and tear resistant properties. Due
to its high resistance to Bio-fuel, Bio-oil and coolant emulsions. It is especially suited for use in the machine, tool making and plant industries
as well as in the steel industry for difficult and problem areas. Suitable in combination with cable trays in dry, moist and wet rooms and
outdoor installation. The high flexibility of this cable type makes it quick and easy to install. Suitable for outdoor lying. These screened cables
are particularly suitable for the interference-free transmission in instrumentation and control engineering applications (electromagnetic
compatibility). For the critical applications we advise for consultation. For applications which go beyond standard solutions (for example for
composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for our especially developed
enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection
table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
25826
25827
25828
25829
25830
25831
25832
25833
25834
25835
25836
25837
25838
25839
25840
25841
25842
25843
25844
25845
25846
25847
25848

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
10G0,5
12G0,5
14G0,5
18G0,5
25G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
10G0,75
12G0,75
14G0,75
18G0,75
25G0,75
2x1
3G1
4G1

Outer
Cop.
approx. mm weight
kg/km
7,5
47,0
7,8
52,0
8,2
55,0
9,9
65,0
10,0
84,0
11,3
115,0
12,5
117,0
13,2
148,0
14,5
157,0
16,8
227,0
8,3
53,0
8,5
62,0
9,5
77,0
10,8
86,0
11,5
107,0
13,1
148,0
14,0
156,0
15,3
214,0
17,3
235,0
18,7
313,0
10,0
60,0
10,2
70,0
11,0
86,0

Weight
approx.
kg/km
90,0
104,0
123,0
131,0
172,0
230,0
250,0
280,0
321,0
445,0
106,0
120,0
150,0
158,0
205,0
290,0
304,0
380,0
418,0
578,0
116,0
135,0
178,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
17
17
17


Part no.
25849
25850
25851
25852
25853
25854
25855
25856
25857
25858
25859
25860
25861
25862
25863
25864
25865
25866
25867
25868
25869
25870
25871

No.cores x
cross-sec.
mm
5G1
7G1
10G1
12G1
14G1
18G1
25G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5
14G1,5
18G1,5
21G1,5
25G1,5
2x2,5
3G2,5
4G2,5
5G2,5

Outer
Cop.
approx. mm weight
kg/km
11,8
99,0
12,7
125,0
14,6
178,0
15,5
186,0
16,7
250,0
18,0
280,0
21,0
378,0
10,5
79,0
10,8
94,0
11,5
113,0
12,5
129,0
13,2
170,0
14,4
226,0
14,9
258,0
16,2
280,0
18,1
340,0
20,3
395,0
21,7
461,0
23,1
533,0
11,8
96,0
13,0
150,0
14,0
174,0
15,1
200,0

Weight
approx.
kg/km
188,0
235,0
340,0
358,0
415,0
500,0
678,0
141,0
164,0
220,0
233,0
323,0
369,0
461,0
481,0
561,0
672,0
780,0
927,0
185,0
278,0
370,0
412,0

AWG-No.
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14

Continuation

C 27
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BIOFLEX-500-JZ-HF-C Biofuel-resistant, abrasion-resistant, recyclable,


environmentally friendly, drag-chain cable, bio-oil resistant 1), meter marking

Part no.
25872
25873
25874
25875
25876
25877
25878
25879
25880

No.cores x
cross-sec.
mm
7G2,5
12G2,5
14G2,5
18G2,5
25G2,5
2x4
3G4
4G4
5G4

Outer
Cop.
approx. mm weight
kg/km
16,2
240,0
21,0
410,0
23,4
480,0
25,7
620,0
31,0
821,0
13,4
135,0
15,8
178,0
17,3
222,0
19,0
328,0

Weight
approx.
kg/km
470,0
738,0
870,0
1100,0
1512,0
235,0
350,0
460,0
550,0

AWG-No.
14
14
14
14
14
12
12
12
12

Part no.
25881
25882
25883
25884
25885
25886
25887

No.cores x
cross-sec.
mm
3G6
4G6
5G6
3G10
4G10
5G10
4G16

Outer
Cop.
approx. mm weight
kg/km
19,5
250,0
21,0
305,0
23,0
441,0
18,8
370,0
25,0
485,0
26,4
610,0
28,0
840,0

Weight
approx.
kg/km
525,0
700,0
800,0
855,0
1140,0
1310,0
1391,0

AWG-No.
10
10
10
8
8
8
6

Dimensions and specifications may be changed without prior notice. (RC03)

Core end sleeves and cable lugs


Core end sleeves
Solderless terminals
Tubular cable lugs
Compression joints

You can nd core end sleeves and cable lugs in our catalogue Cable Accessories.

C 28
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

KOMPOSPEED JZ-HF-500

halogen-free, microbes resistant, cable

for drag chains, meter marking




Technical data

Cable structure

Microbes resistant, halogen-free special


control cable in adapted to DINVDE0281
part13 and DINVDE0245
Temperature range
flexing -30 C to +90 C
fixed installation -40 C to +100 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Isulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Tinned copper, extra fine wire conductors,


bunch stranded to DINVDE0295 cl.6,
BS6360 cl.6 and IEC60228 cl.6
Special thermoplastic polymer core
insulation for better sliding abilities
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
selected lay-length
Core wrapping with fleece thermoplastic
polymer
Outer sheath, special thermoplastic
polymer
Colour black (RAL9005)
with meter marking, change-over in 2011

Properties

Resistant to
UV-radiation
Oxygene
Ozone
Microbes
Hydrofluoric acid
Hydrochloric acid
and diluted sulfuric acid
Low adhesion
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
HELUKABEL KOMPOSPEED JZ-HF-500 control cable is significant due to its resistance against microbes. This cable is specially installed in
rubbish, sewage-treatment plants, composting works, animal stalls and greenhouses.
Suitable for installation for flexible use for medium mechanical, stresses with free movement without tensile stress or forced movements
in dry, moist and wet rooms as well as outside. The high flexibility of this cable type makes it quick and easy to install.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
26307
26308
26309
26310
26311
26312
26313
26314
26315
26316
26317
26318
26319
26320
26321
26322
26323
26324
26325
26326
26327
26328
26329
26330

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75
2x1
3G1
4G1
5G1
7G1
12G1
18G1
25G1

Outer
Cop.
approx. mm weight
kg/km
5,0
9,6
5,3
14,4
5,7
19,1
6,4
24,0
7,5
33,6
9,2
58,0
11,1
86,4
13,4
120,0
5,4
14,4
5,7
21,6
6,4
29,0
7,0
36,0
8,3
50,0
10,2
86,0
12,1
130,0
14,9
180,0
5,7
19,2
6,0
29,0
6,8
38,5
7,4
48,0
8,8
67,0
10,8
115,0
13,0
173,0
15,8
240,0

Weight
approx.
kg/km
42,0
51,0
62,0
88,0
119,0
166,0
273,0
330,0
53,0
70,0
92,0
116,0
159,0
241,0
346,0
681,0
60,0
79,0
107,0
127,0
181,0
284,0
397,0
491,0

AWG-No.
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17


Part no.
26331
26332
26333
26334
26335
26336
26337
26338
26339
26340
26341
26342
26343
26344
26345
26346

No.cores x
cross-sec.
mm
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5

Outer
Cop.
approx. mm weight
kg/km
6,4
29,0
6,8
43,0
7,4
58,0
8,3
72,0
9,9
101,0
12,1
173,0
14,5
259,0
17,8
360,0
7,7
48,0
8,4
72,0
9,1
96,0
10,2
120,0
12,2
168,0
15,2
288,0
18,1
432,0
22,5
600,0

Weight
approx.
kg/km
88,0
104,0
137,0
171,0
264,0
381,0
579,0
789,0
118,0
172,0
197,0
258,0
347,0
561,0
791,0
1090,0

AWG-No.
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14

Dimensions and specifications may be changed without prior notice. (RC03)

C 29
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

KOMPOSPEED JZ-HF-500-C

halogen-free, microbes resistant,

Cu-screened, EMC-preferred type, cable for drag chains, meter marking




C


Technical data

Cable structure

Screened microbes resistant, halogen-free


special control cable in adapted to
DINVDE0281 part13 and DINVDE0245
Temperature range
flexing -30 C to +90 C
fixed installation -40 C to +100 C
Nominal voltage U0/U 300/500 V
Test voltage
core/core 4000 V
core/screen 2000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Tinned copper, extra fine wire conductors,


bunch stranded to DINVDE0295 cl.6,
BS6360 cl.6 and IEC60228 cl.6
Special thermoplastic polymer core
insulation, for better sliding abilities
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
selected lay-length
Core wrapping with fleece
Inner-sheath to special thermoplastic
polymer
Screen of tinned cu braid, coverage approx.
85%
Fleece separator, ensure good dismantling
ability
Outer sheath, special thermoplastic
polymer
Colour black (RAL9005)
with meter marking, change-over in 2011

Properties

Resistant to
UV-radiation
Oxygene
Ozone
Microbes
Hydrofluoric acid
Hydrochloric acid
and diluted sulfuric acid
Low adhesion
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
HELUKABEL KOMPOSPEED JZ-HF-500-C control cable is significant due to its resistance against microbes. This cable is specially installed in
rubbish, sewage-treatment plants, composting works, animal stalls and greenhouses. The inner sheaths of those cables raise the mechanical
stress. For medium mechanical, stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as
well as outside. This screened cable is ideal for use in data signal transmission free from interferences for measurement and control
engineering technology.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
26347
26348
26349
26350
26351
26352
26353
26354
26355
26356
26357
26358
26359
26360
26361
26362
26363
26364
26365
26366

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
6G0,5
7G0,5
12G0,5
18G0,5
25G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75
2x1
3G1
4G1

Outer
Cop.
approx. mm weight
kg/km
6,9
47,0
7,2
52,0
7,8
55,0
8,3
65,0
9,1
70,0
9,6
84,0
11,3
117,0
13,5
157,0
15,8
227,0
7,3
53,0
7,8
62,0
8,3
77,0
9,1
86,0
10,2
107,0
12,6
156,0
14,5
235,0
17,3
313,0
7,8
60,0
8,1
70,0
8,7
86,0

Weight
approx.
kg/km
90,0
101,0
119,0
121,0
144,0
169,0
250,0
321,0
445,0
106,0
116,0
140,0
148,0
198,0
294,0
391,0
562,0
110,0
131,0
171,0

AWG-No.
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
17
17
17


Part no.
26367
26368
26369
26370
26371
26372
26373
26374
26375
26376
26377
26378
26379
26380
26381
26382
26383
26384
26385

No.cores x
cross-sec.
mm
5G1
7G1
12G1
18G1
25G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5

Outer
Cop.
approx. mm weight
kg/km
9,5
99,0
10,9
125,0
13,1
186,0
15,4
280,0
18,6
378,0
8,3
79,0
8,7
94,0
9,5
113,0
10,2
129,0
12,2
170,0
14,5
280,0
16,9
395,0
20,6
533,0
9,8
96,0
10,5
150,0
11,2
174,0
12,6
200,0
14,8
240,0
18,0
410,0

Weight
approx.
kg/km
179,0
229,0
348,0
498,0
669,0
141,0
162,0
210,0
233,0
317,0
471,0
664,0
914,0
182,0
264,0
350,0
394,0
450,0
712,0

AWG-No.
17
17
17
17
17
16
16
16
16
16
16
16
16
14
14
14
14
14
14

Dimensions and specifications may be changed without prior notice. (RC03)

C 30
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SUPERTRONIC-PVC

special cable for drag chains, meter marking

Technical data

Cable structure

Properties

Special PVC cable for drag chains, adapted


to DINVDE0245,0281
Very high flexible due to special
construction
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +70 C
(short time +105 C)
Nominal voltage 350 V
Test voltage 1500 V
Breakdown voltage min. 3000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 5x cable
fixed installation 3x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, extra fine wire conductors,


to DINVDE0295 cl.6 col.4 and5
Special PVC core insulation TI2, to
DINVDE0281 part1
Cores colour coded to DIN47100, see
Technical Informations
Cores stranded in layers with optimal
selected lay-length
Core wrapping with textile tape
Special PVC outer sheath TM2, to
DINVDE0281 part1
Colour grey (RAL 7001)
with meter marking, change-over in 2011


Extensively oil resistant


Chemical Resistance - see table Technical
Informations
Adhesion-free
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application
The ideal cable for use in cable trays. This high flexible cable is ideal for all areas requiring a high and fast flexing cable including the machine
industries, robotics and all areas of highly mobile machine parts. The long working life offers a secure performance as well as economy. For
applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
49550
49551
49552
49553
49554
49555
49556
49557
49558
49559
49560
49561
49562
49563
49564
49565
49566

No.cores x
cross-sec.
mm
2x0,14
3x0,14
4x0,14
5x0,14
7x0,14
10x0,14
12x0,14
14x0,14
18x0,14
24x0,14
25x0,14
2x0,25
3x0,25
4x0,25
5x0,25
7x0,25
10x0,25

Outer
Cop.
approx. mm weight
kg/km
3,5
2,8
3,7
4,1
3,9
5,6
4,2
7,0
4,8
9,8
6,2
14,0
6,3
16,8
6,6
19,6
7,2
25,2
8,5
33,6
8,6
35,0
4,2
5,0
4,4
7,5
4,7
10,0
5,6
12,5
6,1
17,5
7,2
25,0

Weight
approx.
kg/km
23,0
25,0
30,0
35,0
49,0
64,0
71,0
77,0
90,0
119,0
124,0
28,0
33,0
39,0
50,0
63,0
83,0

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
24
24
24
24
24
24


Part no.
49567
49568
49569
49570
49571
49572
49573
49574
49575
49576
49577
49578
49579
49580
49581
49582

No.cores x
cross-sec.
mm
12x0,25
14x0,25
18x0,25
24x0,25
25x0,25
2x0,34
3x0,34
4x0,34
5x0,34
7x0,34
10x0,34
12x0,34
14x0,34
18x0,34
24x0,34
25x0,34

Outer
Cop.
approx. mm weight
kg/km
7,5
30,1
7,9
35,0
8,9
45,0
10,4
60,0
10,5
62,5
4,6
6,8
4,8
10,2
5,2
13,6
6,1
17,0
7,0
23,8
8,4
34,0
8,5
40,8
9,0
47,6
10,1
61,2
12,0
81,5
12,2
85,0

Weight
approx.
kg/km
95,0
107,0
130,0
170,0
177,0
33,0
42,0
56,0
64,0
84,0
116,0
133,0
150,0
182,0
240,0
250,0

AWG-No.
24
24
24
24
24
22
22
22
22
22
22
22
22
22
22
22

Dimensions and specifications may be changed without prior notice. (RC03)

C 31
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SUPERTRONIC-C-PVC

special cable for drag chains, EMC-preferred

type, meter marking




C


Technical data

Cable structure

Properties

Special PVC cable for drag chains, adapted


to DINVDE0245,0281
Very high flexible due to special
construction
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +70 C
(short time +105 C)
Nominal voltage 350 V
Test voltage 1500 V
Breakdown voltage min. 3000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, extra fine wire conductors,


to DINVDE0295 cl.6 col.4 and5
Special PVC core insulation TI2, to
DINVDE0281 part1
Cores colour coded to DIN47100, see
Technical Informations
Cores stranded in layers with optimal
selected lay-length
Core wrapping with textile tape
Tinned copper braided screen, approx. 85%
coverage
Special PVC outer sheath TM2, to
DINVDE0281 part1
Colour grey (RAL 7001)
with meter marking, change-over in 2011


Extensively oil resistant


Chemical Resistance - see table Technical
Informations
Adhesion-free
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application
The ideal cable for use in cable trays. This high flexible cable is ideal for all areas requiring a high and fast flexing cable including the machine
industries, robotics and all areas of highly mobile machine parts. The long working life offers a secure performance as well as economy. For
applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
49620
49621
49622
49623
49624
49625
49626
49627
49628
49629
49630
49631
49632
49633
49634
49635
49636
49637

No.cores x
cross-sec.
mm
2x0,14
3x0,14
4x0,14
5x0,14
7x0,14
10x0,14
12x0,14
14x0,14
18x0,14
24x0,14
25x0,14
2x0,25
3x0,25
4x0,25
5x0,25
7x0,25
10x0,25
12x0,25

Outer
Cop.
approx. mm weight
kg/km
4,0
11,2
4,2
14,1
4,4
15,5
4,7
18,3
5,3
27,6
6,7
39,3
6,8
41,1
7,1
45,3
7,7
54,1
9,0
66,3
9,1
68,4
4,7
14,9
4,9
18,8
5,2
21,3
5,6
31,0
6,7
39,6
7,8
53,9
8,1
59,1

Weight
approx.
kg/km
33,0
36,0
41,0
46,0
70,0
88,0
97,0
105,0
122,0
156,0
162,0
39,0
45,0
52,0
70,0
88,0
114,0
128,0

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
24
24
24
24
24
24
24


Part no.
49638
49639
49640
49641
49642
49643
49644
49645
49646
49647
49648
49649
49650
49651
49652

No.cores x
cross-sec.
mm
14x0,25
18x0,25
24x0,25
25x0,25
2x0,34
3x0,34
4x0,34
5x0,34
7x0,34
10x0,34
12x0,34
14x0,34
18x0,34
24x0,34
25x0,34

Outer
Cop.
approx. mm weight
kg/km
8,5
64,2
9,5
78,4
11,0
89,9
11,1
101,0
5,2
16,1
5,4
28,7
5,8
35,7
6,7
39,1
7,6
52,7
9,0
67,4
9,1
76,4
9,6
85,3
10,7
99,7
12,6
147,1
12,8
155,0

Weight
approx.
kg/km
140,0
166,0
210,0
220,0
46,0
62,0
80,0
88,0
116,0
156,0
167,0
195,0
225,0
312,0
325,0

AWG-No.
24
24
24
24
22
22
22
22
22
22
22
22
22
22
22

Dimensions and specifications may be changed without prior notice. (RC03)

C 32
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SUPERTRONIC-PUR

special cable for drag chains, meter marking

Technical data

Cable structure

Properties

Special PUR drag chain cables adapted to


DIN VDE 0281 part 13
Very high flexible due to special
construction
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage 350 V
Test voltage 1500 V
Breakdown voltage min. 3000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 5x cable
fixed installation 3x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, extra fine wire conductors,


to DINVDE0295 cl.6, col.4 and 5, cl.6 and
IEC60228 cl.6
Oil resistant PVC core insulation TI2, in
adapted to DINVDE0281 part1, for better
sliding abilities
Cores are stranded in layer with short
lay-length
Cores colour coded to DIN47100
Core wrapping with textile tape
Special full-polyurethane outer jacket
TMPU to DINVDE0282 part10, appendixA
Outer jacket grey (RAL7001), surface mat
with meter marking, change-over in 2011


Features
High flexibility at low temperature, high
abrasion resistance, break and cut-resistant,
tear resistant, flame retardant.
Resistant to UV-radiation, Oxygen, Ozone,
Hydrolyse, Oil.
Conditional resistant to Microbes,
Hydraulic liquidity, Alkalis, Lye.
The PUR outer jacket is extremely robust
with high tear, abrasion and oil-resistance.
Adhesion-free.
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.


Application
Perfect for use with cable trays. This highly flexible and screened PUR control cable is ideal for use wherever frequent high flexing motion
is required, e.g. in robotics or all moving parts. The long working life of this cable makes it both efficient and economic.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
49583
49584
49585
49586
49587
49588
49589
49590
49591
49592
49593
49594
49595
49596
49597
49598
49599

No.cores x
cross-sec.
mm
2x0,14
3x0,14
4x0,14
5x0,14
7x0,14
10x0,14
12x0,14
14x0,14
18x0,14
24x0,14
25x0,14
2x0,25
3x0,25
4x0,25
5x0,25
7x0,25
10x0,25

Outer
Cop.
approx. mm weight
kg/km
3,5
2,8
3,7
4,1
3,9
5,6
4,2
7,0
4,9
9,8
6,2
14,0
6,4
16,8
6,6
19,6
7,3
25,2
8,5
33,6
8,6
35,0
4,1
5,0
4,3
7,5
4,8
10,0
5,2
12,5
6,2
17,5
7,4
25,0

Weight
approx.
kg/km
22,0
24,0
29,0
33,0
47,0
59,0
67,0
74,0
86,0
115,0
120,0
27,0
33,0
40,0
48,0
60,0
79,0

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
24
24
24
24
24
24


Part no.
49600
49601
49602
49603
49604
49605
49606
49607
49608
49609
49610
49611
49612
49613
49614
49615

No.cores x
cross-sec.
mm
12x0,25
14x0,25
18x0,25
24x0,25
25x0,25
2x0,34
3x0,34
4x0,34
5x0,34
7x0,34
10x0,34
12x0,34
14x0,34
18x0,34
24x0,34
25x0,34

Outer
Cop.
approx. mm weight
kg/km
7,6
30,1
7,9
35,0
8,9
45,0
10,0
60,0
10,6
62,5
4,5
6,8
4,9
10,2
5,3
13,6
5,8
17,0
6,9
23,8
8,4
34,0
8,6
40,8
9,0
47,6
10,1
61,2
12,0
81,5
12,2
85,0

Weight
approx.
kg/km
91,0
102,0
125,0
163,0
170,0
32,0
40,0
55,0
60,0
80,0
112,0
127,0
142,0
175,0
229,0
238,0

AWG-No.
24
24
24
24
24
22
22
22
22
22
22
22
22
22
22
22

Dimensions and specifications may be changed without prior notice. (RC03)

C 33
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SUPERTRONIC-C-PUR

special cable for drag chains,

halogen-free, EMC-preferred type, meter marking




C


Technical data

Cable structure

Special PUR drag chain cables, screened, in


adapted to DINVDE0281 part13
Temperature range
flexing -40 C to +70 C
fixed installation -50 C to +70 C
Nominal voltage
0,14 mm 350 V
0,25 and 0,34 mm 500 V
Test voltage
0,14 mm 800 V
0,25 and 0,34 mm 1200 V
Capacitance core/core <80 nF/km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x10

Plain copper conductors extra fine wire


stranded to DINVDE0295 cl.6, col.4 and
5, IEC60228 cl.6
Oil resistant TPE core insulation
Cores are stranded in layer with short
lay-length
Cores colour coded to DIN47100
Core wrapping with textile tape
Tinned copper screened braiding. Due to
the technical facilities, the copper braiding
can be mixed and webed with a portion of
synthetic fibres
Special full-polyurethane outer jacket
TMPU to DINVDE0282 part10, appendixA
Outer jacket grey (RAL7001)
with meter marking, change-over in 2011

Properties

Features
High flexibility at low temperature, high
abrasion resistance, break and cut-resistant,
tear resistant, flame retardant.
Resistant to UV-radiation, Oxygen, Ozone,
Hydrolyse, Oil.
Conditional resistant to Microbes,
Hydraulic liquidity, Alkalis, Lye.
The PUR outer jacket is extremely robust
with high tear, abrasion and oil-resistance.
Adhesion-free.
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.


Application
Used for installation in dry, moist and wet environments as well as for outdoors, for free movement without forced motion and for flexible
routing without forced motion, for proven use as drag-chain cables. Suitable as a highly flexible control cable for fast hoisting and bending
stresses in machinery and tooling construction, in robotics engineering and for continuously moving machinery parts.
The long working life of this cable makes it both efficient and economic. The copper braided screening offers effective protection from
both internal and external interference.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
49653
49654
49655
49656
49657
49658
49659
49660
49661
49662
49663
49664
49665
49666
49667
49668
49669

No.cores x
cross-sec.
mm
2x0,14
3x0,14
4x0,14
5x0,14
7x0,14
10x0,14
12x0,14
14x0,14
18x0,14
24x0,14
25x0,14
2x0,25
3x0,25
4x0,25
5x0,25
7x0,25
10x0,25

Outer
Cop.
approx. mm weight
kg/km
4,1
11,2
4,3
14,1
4,5
15,5
4,8
18,3
5,7
27,8
6,7
39,3
6,9
42,1
7,1
45,3
7,8
54,1
9,0
66,3
9,1
68,4
4,6
14,9
4,8
18,8
5,3
21,3
5,7
31,0
6,7
39,6
8,2
53,9

Weight
approx.
kg/km
32,0
35,0
40,0
45,0
66,0
86,0
94,0
102,0
118,0
149,0
156,0
38,0
44,0
51,0
68,0
82,0
110,0

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
24
24
24
24
24
24


Part no.
49670
49671
49672
49673
49674
49675
49676
49677
49678
49679
49680
49681
49682
49683
49684
49685

No.cores x
cross-sec.
mm
12x0,25
14x0,25
18x0,25
24x0,25
25x0,25
2x0,34
3x0,34
4x0,34
5x0,34
7x0,34
10x0,34
12x0,34
14x0,34
18x0,34
24x0,34
25x0,34

Outer
Cop.
approx. mm weight
kg/km
8,4
59,1
8,7
64,2
9,5
78,4
11,0
89,9
11,1
101,0
5,0
18,1
5,4
28,7
6,2
35,7
6,7
39,1
7,6
52,7
9,2
67,4
9,4
76,4
10,0
85,5
10,9
99,7
12,6
147,1
12,8
155,0

Weight
approx.
kg/km
124,0
135,0
160,0
202,0
211,0
45,0
60,0
76,0
82,0
110,0
148,0
166,0
185,0
216,0
300,0
313,0

AWG-No.
24
24
24
24
24
22
22
22
22
22
22
22
22
22
22
22

Dimensions and specifications may be changed without prior notice. (RC03)

C 34
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SUPER-PAAR-TRONIC-C-PUR

cable for drag chains,

halogen-free, EMC-preferred type, meter marking




Technical data

Cable structure

Properties

Special PETP-PUR cable, twisted in


pairs,adapted to DINVDE0245,0812
Conductor and loop resistance as per
DINVDE0295, for 0,25 mm see pages
Technical-Informations
Temperature range
flexing -40 C to +70 C
fixed installation -50 C to +70 C
Nominal voltage 350 V
Test voltage 1500 V
Insulation resistance
min. 100 MOhm x km
Mutual capacitance
approx. 135 nF/km
Minimum bending radius
flexing at 0,25 mm
approx. 7,5xcable
fixed installation at 0,25 mm
approx. 4xcable
flexing at 0,5-1,0 mm
approx. 10xcable
fixed installation at 0,5-1,0 mm
approx. 5xcable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Plain copper conductors, extra fine wire


stranded to DINVDE0295 cl.6, col.4,
BS6360 cl.6 and IEC60228 cl.6
Special core insulation of TPE
Core identification as per DIN47100
Cores twisted in pairs, the pairs torsion-free
stranded in layers
Special fleece over outer layer
Tinned copper screened braiding, approx.
85% coverage
Full-polyurethane outer jacket TMPU, to
DINVDE0282 part10, appendixA
Outer jacket grey (RAL 7001)
with meter marking, change-over in 2011


Very good oil resistant, test method


according to DINVDE0472 part803
Resistant to weather, ozone and
UV-radiation
Chemical resistant to solvents, acids, lyes
and hydraulic liquidity
Flame retardant
Guaranteed permanent application in
multi-shift operation under extreme high
bending stress
High resistant to mechanical strain
High property of alternating bending
strength
Long life durabilities through low
friction-resistance by using the TPE-core
insulation where the core are stranded in
layers
High tensile strength-, abrasion- and
impact resistant at low temperature
Adhesion-low
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application
These pair stranded and overall screened special cables for drag chains offer the operational possibilities where the outer electrical influences
at high frequence cause interference of impulse transmission, are applied for permanent flexible operations in machineries, machine tools,
robot technics, for movable automated machinery parts and multi-shift-operation as a transmission-cable.
These high flexible data cables are developed according to the newest state of technology improvement and with its sliding abilities by using
the PETP-core insulation and adhesion-low and cut-resistant PUR-outer jacket, guaranteed an optimum life durabilities and highly economic.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
19101
19102
19103
19104
19105
19106
19107
19108
19109
19119
19120
19121
19122
19123
19124
19125
19126
19127

No.pairs x
cross-sec.
mm
1 x 2 x 0,25
2 x 2 x 0,25
3 x 2 x 0,25
4 x 2 x 0,25
5 x 2 x 0,25
6 x 2 x 0,25
8 x 2 x 0,25
10 x 2 x 0,25
14 x 2 x 0,25
1 x 2 x 0,5
2 x 2 x 0,5
3 x 2 x 0,5
4 x 2 x 0,5
5 x 2 x 0,5
6 x 2 x 0,5
8 x 2 x 0,5
10 x 2 x 0,5
14 x 2 x 0,5

Outer
approx.
mm
4,7
6,5
6,6
7,1
8,2
8,5
9,2
10,7
11,5
5,5
7,9
8,2
8,9
10,3
10,7
11,8
13,5
14,8

Cop.
weight
kg/km
14,0
32,0
38,4
43,2
51,5
71,8
74,4
90,0
111,2
22,0
50,0
71,8
74,4
84,5
99,6
144,3
176,0
215,4

Weight
approx.
kg/km
28,0
61,0
73,0
90,0
105,0
133,0
156,0
188,0
220,0
47,0
100,0
131,0
149,0
169,0
196,0
285,0
344,0
401,0

AWG-No.


Part no.

24
24
24
24
24
24
24
24
24
20
20
20
20
20
20
20
20
20

19128
19129
19130
19131
19132
19133
19134
19135
19136
19137
19138
19139
19140
19141

No.pairs x
cross-sec.
mm
1 x 2 x 0,75
2 x 2 x 0,75
3 x 2 x 0,75
4 x 2 x 0,75
5 x 2 x 0,75
6 x 2 x 0,75
8 x 2 x 0,75
10 x 2 x 0,75
14 x 2 x 0,75
1x2x1
2x2x1
3x2x1
4x2x1
5x2x1

Outer
approx.
mm
6,3
9,0
9,1
9,9
11,5
11,9
13,1
15,0
16,4
6,9
10,0
10,2
11,3
13,1

Cop.
weight
kg/km
34,0
60,0
85,7
93,6
113,0
130,4
192,2
258,0
316,6
42,0
73,0
93,6
117,8
139,0

Weight
approx.
kg/km
61,0
113,0
158,0
173,0
203,0
231,0
343,0
467,0
546,0
71,0
130,0
170,0
204,0
238,0

AWG-No.
18
18
18
18
18
18
18
18
18
17
17
17
17
17

Dimensions and specifications may be changed without prior notice. (RC03)

C 35
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Research & Development


HELUKABEL is responding to market
demands with continuous new development
of cable types

Photos: Helukabel

We continuously develop new connection types with special


construction for extreme conditions in collaboration with our
Customers, such as very small bending radius, or repeated bending strain with long life durabilities for extended operation
in multilayer installations.
These new products are tested in our modern wellequipped Test
Centre before going into production.

C 36
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Motor, Servo &


Feedback Cables

D1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Motor, Servo & Feedback Cables


D
A multitude of applications requires the
construction of many special cables.
Corresponding to the customers requirements,
those cables may be constructed with different
stranding elements and cross-sections of
the cable. In this case we are speaking about
combination or hybrid cables.
There could turn out to be technical reasons,
specic to the application, for using different
insulating materials or choosing special stranding
types or a special screen, for example multiple or
mixed screening.

Motor, Servo & Feedback Cables according to


UL/CSA see in chapter N.

D2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description

Page

TOPFLEX 600-PVC,for power supply connections 0,6/1kV, meter marking ..................................................................................................


TOPFLEX 611-PUR,for power supply connections 0,6/1kV, meter marking .............................................................................................

TOPFLEX 600-C-PVC,Motor power supply cable 0,6/1kV, meter marking ...................................................................................................


TOPFLEX 611-C-PUR,Motor power supply cable 0,6/1kV, halogen-free, meter marking .............................................................................

TOPSERV 130,flexible servo cable 0,6/1kV, meter marking.............................................................................................................................


TOPSERV 110 / 120 / Feedback-Cable,drag chain cable, 0,6/1kV EMC-preferred type, servo/feedback cable, high flexible, meter marking........

Tachofeedback-Cable-C-PVC, Incremental feedback-cable-C-PVC,EMC-preferred type, meter marking...................................................


Tachofeedback-Cable-C-PUR, Incremental feedback-cable-C-PUR,drag chain cable, EMC-preferred type, meter marking........................

TOPFLEX 240-PVC / 240-PUR,special measuring and data cable, EMC-preferred type, meter marking..................................................................

TOPFLEX-PVC,feedback cable, EMC-preferred type, meter marking.................................................................................................................


TOPFLEX-PUR,drag chain feedback cable, EMC-preferred type, halogen-free, meter marking.............................................................................

TOPFLEX-PVC,feedback cable, EMC-preferred type, meter marking.................................................................................................................


TOPFLEX-PUR,drag chain feedback cable, EMC-preferred type, halogen-free, meter marking.............................................................................
TOPFLEX -EMV-2YSLCY-J,for power supply connections to frequency converters, double screened,
TOPFLEX

.................................
-EMV-UV-2YSLCYK-J,for power supply connections to frequency converters, double screened, 0,6/1kV, meter marking..........................
-EMV-3 PLUS 2YSLCY-J,for power supply connections to frequency converters, double screened, 0,6/1kV, meter marking......................
-EMV-UV-3 PLUS 2YSLCYK-J,for power supply connections to frequency converters, double screened, 0,6/1kV, meter marking...............
Motor 109,low capacitance power supply cable 0,6/1kV, increased ampacity, halogen-free, meter marking..............................................

TOPFLEX
TOPFLEX
TOPFLEX

0,6/1kV, meter marking

D 4
D 5
D 6
D 7
D 8
D 9

D 10
D 11
D 12
D 13
D 14
D 15
D 16
D 17
D 19
D 21
D 23
D 25

D3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX 600-PVC

for power supply connections 0,6/1kV, meter marking

Technical data

Cable structure

Properties

Special PVC-insulated sheathed cable


Based on DINVDE0293, 0295
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 600/1000 V
Test voltage 4000 V
Breakdown voltage
min. 8000V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing approx. 7,5x cable
fixed installation approx. 4x cable
Radiation resistance
up to 80x106 cJ/kg (to 80 Mrad)

Finely stranded, plain Cu wire conductor


according to VDE0295 cl.5 and IEC60228
cl.5
PVC core insulation
Cores black with sequential numbering
imprinted in white, according to
DINVDE0293
Earth core green-yellow
Cores stranded in layers with optimal
lay-length
Special-PVC-insulated outer jacket
Colour grey (RAL 7001)
with meter marking, change-over in 2011

PVC outer jacket: extensively oil resistant


Chemical Resistance - see table Technical
Informations
Flame retardant and self-extinguishing,
test method B according to DINVDE0472
part804 and IEC60332-1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

For use in drag chains, we recommend our


versions TOPFLEX 611-PUR and TOPFLEX
611-C-PUR.
screened analogue type:
TOPFLEX 600-C-PVC, see page D6

Application
As supply cable for electronically controlled servo-motors and connections to DNC motors. The cable is suitable for permanent and flexible
installation for medium mechanical loads in dry, damp and wet environments.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
22860
22861
22862
22863
22864
22865

No.cores x
cross-sec.
mm
4G1,5
4G2,5
4G4
4G6
4G10
4G16

Outer
Cop.
approx. mm weight
kg/km
9,6
58,0
11,2
95,0
13,0
154,0
14,5
231,0
18,2
384,0
22,3
615,0

Weight
approx.
kg/km
130,0
220,0
330,0
445,0
660,0
1060,0

AWG-No.
16
14
12
10
8
6


Part no.
22866
22867
22868
22869
22854
22855

No.cores x
cross-sec.
mm
4G25
4G35
4G50
4G70
4G95
4G120

Outer
Cop.
approx. mm weight
kg/km
27,4
960,0
30,0
1344,0
35,8
1920,0
40,9
2640,0
46,2
3648,0
51,6
4608,0

Weight
approx.
kg/km
1805,0
2060,0
2900,0
4050,0
5540,0
7000,0

AWG-No.
4
2
1
2/0
3/0
4/0

Dimensions and specifications may be changed without prior notice. (RD01)

D4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX 611-PUR

for power supply connections 0,6/1kV, meter

marking


Technical data

Cable structure

Properties

Special-PUR drag chain cable Based on


DINVDE0293, 0295, 0250, 0281
Temperature range
flexing -30 C to +80 C
fixed installation -50 C to +90 C
Nominal voltage U0/U 600/1000 V
Test voltage 4000 V
Insulation resistance
min. 20 MOhm x km
Min. bending radius
flexing 7,5x cable
fixed installation 4x cable

Bare copper, ultra-fine wire conductors


acc. to DINVDE0295 cl.6, BS6360 cl.6
and/or IEC60228 cl.6
TPE-core insulation
Cores black with sequential numbering
imprinted in white, according to
DINVDE0293
Green-yellow earth core
Cores stranded together with optimal
lay-length and stabilising filler
Fleece wrapping facilitates sliding
PUR-insulated outer jacket
Sheath colour grey (RAL7001)
with meter marking, change-over in 2011

Adhesion-free, extremely abrasion


resistant, halogen-free, flame retardant,
resistant to hydrolysis and microbial attack
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
PUR-jacket flame retardant according to
VDE0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)


Note

For extreme applications extending beyond


standard solutions we recommend that
you request our questionnaire, which has
been especially designed for energy supply
systems.
Please observe applicable installation
regulations for use in energy supply chains.
screened analogue type:
TOPFLEX 611-C-PUR, see page D7

Application
As optimized supply cable for the supply to motors, in particular to DNC motors, servo-motors. These cables are specially designed for use
in power drag chains, handling equipment, robotics, tooling machinery, processing and manufacturing machinery. Optimised insulation
materials ensure resistance to oils (including mineral oils), greases, coolants, hydraulic fluids as well as many alkalis and solvents. Favourable
outer diameters, reduced weights and enhanced torsion characteristics assure the use in multi-layer operations with extremely high
continuous bending loads. Suitable for outdoor use.
=The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
22870
22871
22872
22873
22874
22875

No.cores x
cross-sec.
mm
4G1,5
4G2,5
4G4
4G6
4G10
4G16

Outer
Cop.
approx. mm weight
kg/km
8,0
58,0
10,8
95,0
12,5
154,0
14,8
231,0
18,8
384,0
22,8
615,0

Weight
approx.
kg/km
125,0
215,0
310,0
470,0
760,0
1250,0

AWG-No.
16
14
12
10
8
6


Part no.
22876
22877
22978
22979
22980
22981

No.cores x
cross-sec.
mm
4G25
4G35
4G50
4G70
4G95
4G120

Outer
Cop.
approx. mm weight
kg/km
26,9
960,0
30,7
1344,0
36,5
1920,0
41,6
2640,0
48,2
3648,0
51,6
4608,0

Weight
approx.
kg/km
1510,0
2100,0
2950,0
4090,0
5580,0
7040,0

AWG-No.
4
2
1
2/0
3/0
4/0

Dimensions and specifications may be changed without prior notice. (RD01)

D5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX 600-C-PVC

Motor power supply cable 0,6/1kV, meter marking

Technical data

Cable structure

Properties

Special PVC-insulated sheathed cable


Based on DINVDE0293, 0295
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 600/1000 V
Test voltage 4000 V
Breakdown voltage
min. 8000V
Coupling resistance
max. 250 Ohm/km
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing approx. 7,5x cable
fixed installation approx. 4x cable
Radiation resistance
up to 80x106 cJ/kg (to 80 Mrad)

Finely stranded, plain Cu wire conductor


according to VDE0295 cl.5 and IEC60228
cl.5
PVC core insulation
Cores black with sequential numbering
imprinted in white, according to
DINVDE0293
Earth core green-yellow
Cores stranded in layers with optimal
lay-length
Special-PVC-insulated outer jacket
PVC inner jacket
Tinned copper braided screening, coverage
approx. 85%
Colour grey (RAL 7001)
with meter marking, change-over in 2011

PVC outer jacket: extensively oil resistant


Chemical Resistance - see table Technical
Informations
Flame retardant and self-extinguishing to
VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Applicatons as described above with
additional compliance with electromagnetic
compatibility (EMC compatibility)
requirements on account of the 90%
coverage by the braided screening


Note

For use in drag chains, we recommend our


versions TOPFLEX 611-PUR and TOPFLEX
611-C-PUR.
unscreened analogue type:
TOPFLEX 600-PVC, see page D4

Application
As supply cable for electronically controlled servo-motors and connections to DNC motors. The cable is suitable for permanent and flexible
installation for medium mechanical loads in dry, damp and wet environments.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
22960
22961
22962
22963
22964
22965

No.cores x
cross-sec.
mm
4G1,5
4G2,5
4G4
4G6
4G10
4G16

Outer
Cop.
approx. mm weight
kg/km
11,8
99,0
13,8
169,0
15,7
234,0
17,3
316,0
21,5
549,0
26,1
807,0

Weight
approx.
kg/km
250,0
360,0
530,0
620,0
1050,0
1465,0

AWG-No.
16
14
12
10
8
6


Part no.
22966
22967
22856
22857
22858
22859

No.cores x
cross-sec.
mm
4G25
4G35
4G50
4G70
4G95
4G120

Outer
Cop.
approx. mm weight
kg/km
31,7
1169,0
34,5
1680,0
40,7
2370,0
46,0
3257,0
51,3
4060,0
56,4
5231,0

Weight
approx.
kg/km
1920,0
2515,0
3315,0
4600,0
6060,0
7315,0

AWG-No.
4
2
1
2/0
3/0
4/0

Dimensions and specifications may be changed without prior notice. (RD01)

D6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX 611-C-PUR

Motor power supply cable 0,6/1kV,

halogen-free, meter marking




Technical data

Cable structure

Properties

Special-PUR drag chain cable Based on


DINVDE0293, 0295, 0250, 0281
Temperature range
flexing -30 C to +80 C
fixed installation -50 C to +90 C
Nominal voltage U0/U 600/1000 V
Test voltage 4000 V
Coupling resistance
max. 250 Ohm/km
Insulation resistance
min. 20 MOhm x km
Min. bending radius
flexing 10x cable
fixed installation 5x cable

Bare copper, ultra-fine wire conductors


acc. to DINVDE0295 cl.6, BS6360 cl.6
and/or IEC60228 cl.6
TPE-core insulation
Cores black with sequential numbering
imprinted in white, according to
DINVDE0293
Green-yellow earth core
Cores stranded together with optimal
lay-length and stabilising filler
Fleece wrapping facilitates sliding
PUR-insulated outer jacket
TPE inner jacket
Tinned copper braided screening, coverage
approx. 85%
Sheath colour grey (RAL7001)
with meter marking, change-over in 2011

Adhesion-free, extremely abrasion


resistant, halogen-free, flame retardant,
resistant to hydrolysis and microbial attack
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
PUR-jacket flame retardant according to
VDE0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)


Note

For extreme applications extending beyond


standard solutions we recommend that
you request our questionnaire, which has
been especially designed for energy supply
systems.
Please observe applicable installation
regulations for use in energy supply chains.
unscreened analogue type:
TOPFLEX 611-PUR, see page D5

Application
As optimized supply cable for the supply to motors, in particular to DNC motors, servo-motors. These cables are specially designed for use
in power drag chains, handling equipment, robotics, tooling machinery, processing and manufacturing machinery. Optimised insulation
materials ensure resistance to oils (including mineral oils), greases, coolants, hydraulic fluids as well as many alkalis and solvents. Favourable
outer diameters, reduced weights and enhanced torsion characteristics assure the use in multi-layer operations with extremely high
continuous bending loads. Suitable for outdoor use.
=The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
22970
22971
22972
22973
22974
22975

No.cores x
cross-sec.
mm
4G1,5
4G2,5
4G4
4G6
4G10
4G16

Outer
Cop.
approx. mm weight
kg/km
11,3
99,0
13,5
169,0
16,0
234,0
17,8
316,0
22,2
549,0
27,2
807,0

Weight
approx.
kg/km
220,0
340,0
490,0
680,0
1035,0
1460,0

AWG-No.
16
14
12
10
8
6


Part no.
22976
22977
22982
22983
22984
22985

No.cores x
cross-sec.
mm
4G25
4G35
4G50
4G70
4G95
4G120

Outer
Cop.
approx. mm weight
kg/km
31,2
1169,0
35,2
1680,0
42,5
2370,0
48,8
3257,0
54,6
4060,0
58,5
5231,0

Weight
approx.
kg/km
1990,0
2535,0
3360,0
4650,0
6090,0
7380,0

AWG-No.
4
2
1
2/0
3/0
4/0

Dimensions and specifications may be changed without prior notice. (RD01)

D7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPSERV 130 flexible servo cable 0,6/1kV, meter marking




Technical data

Cable structure

Properties

Special PVC drag chain cable acc. to DIN


VDE 0281, 0245, 0250
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage
power supply cores U0/U 600/1000 V
control cores U0/U 300/500 V
A.c. test voltage, 50 Hz
power supply cores 4000 V
control cores 1000 V
Insulation resistance
min. 20 MOhm x km
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
flexing approx. 10x cable
fixed installation approx. 5x cable

Bare copper, fine wire conductors to


DINVDE0295 cl.5 and/or IEC60228 cl.5
Special-PVC core insulation
Core identification
-Power supply cores black with imprint
white and earth core green-yellow
-Control cores:
0,34mm2: white/brown, green/yellow
from 0,5mm2: black with imprint white
Screening of the control cores in pairs
wrapped with plastic aluminium foil, copper
drain-wire tinned and tinned copper
braided screening, approx. coverage 85%
Control cores stranded in pairs and laid up
in layers together with the power supply
cores with optimal lay length
Polyester fleece wrapping
Overall screening from tinned copper braid,
optimal. coverage min. 85%
Special-PVC outer sheath, grey (RAL 7001)
with meter marking, change-over in 2011


extensive oil-resistant
self-extinguishing and flame retardant
according to VDE0482-332-1-2, DIN
EN60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Optimum compliance with requirements
for electromagnetic compatibility (EMC) by
approx. 85% coverage from the braided
screen
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers.

Application
The supply conductors for these cables are ideally combined with the control conductors for the brake function and the thermal protection.
Accurately working servomotors require high performance, reliable and durable cables. These requirements are fully met. The cables have
an additional total shield for EMC compatibility. The production is based on the specifications of well known servo-drive and control system
manufacturers as well as on several VDE standards.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
59212
( 4 x 0,75 + 2 x (1G0,34))
59213
( 4 x 1,5 + 2 x (1G0,75))
59214
( 4 x 2,5 + 2G0,75)
59215
( 4 x 4 + 2G0,75 + 2 x 1,0)

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
10,7
109,0
167,0
12,7
154,0
241,0
14,7
229,0
381,0
16,5
317,0
480,0

AWG-No.
17
17
17
17


Part no. No.cores x
cross-sec.
mm
59216
( 4 x 6 + 2G0,75 + 2 x 1,0)
59217
( 4 x 10 + 2G0,75 + 2 x 1,0)
59218
( 4 x 16 + 2 x (1G1,0))
59219
( 4 x 25 + 2 x (1G1,5))

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
17,6
420,0
604,0
21,6
604,0
831,0
24,4
891,0
1215,0
30,0
1271,0
1647,0

AWG-No.
17
17
17
17

Dimensions and specifications may be changed without prior notice. (RN07)

D8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPSERV 110 / 120 / Feedback-Cable drag


chain cable, 0,6/1kV EMC-preferred type, servo/feedback cable, high flexible, meter
marking


Technical data

Cable structure

Properties

Spezial-PUR drag chain cable based on


DINVDE0295, 0250, 0281
Temperature range
flexing -40 C to +90 C
fixed installation -40 C to +90 C
Nominal voltage
power supply cores U0/U 600/1000 V
control cores U0/U 300/500 V
Test voltage
power supply cores 4000 V
control cores 1000 V
Power rating
to DINVDE0298 part4
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing approx. 7,5x cable
fixed installation approx. 4x cable
Coupling resistance
max. 250 Ohm/km

Plain copper conductor, ultra-fine wire


for TOPSERV 110:
1 mm = 19x0,25 mm
TPE core insulation, halogen-free
Core identification:
Power supply cores black with imprint U1,
V2, W3 and earth core green-yellow,
Control cores black with imprint BR1, BR2
or nos. 5-6 and 7-8 for the 2-pair-version
Screening of the control cores in pairs with
Al film, tinned drain wire and tinned Cu
braid; single pair with tinned Cu braid only
Control cores stranded in pairs and laid up
in layers together with the power supply
cores
Fleece wrapping
Overall screening of tinned cu braid, visible
coverage min. 80%
Fleece wrapping
PUR-outer sheath, flame-resistant
Colour petrol (RAL 5018)
with meter marking, change-over in 2011


PUR-outer sheath flame retardant, low


adhesion, resistant to hydrolysis and
microbial attack, halogen-free
These highly flexible cables are fitted with
an additional overall screen to assure EMC
compatibility, i.e. the protection against
electromagnetic interference
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

For extreme applications extending beyond


standard solutions we recommend that
you request our questionnaire, which has
been especially designed for energy supply
systems.
Please observe applicable installation
regulations for use in energy supply chains.

Application
The combination of feeder cores with the control cores for the braking function and the thermal protection in these cables is ideal. Precision
servomotors, as used today in many areas of highly-automated manufacturing processes, call for high-quality, reliable and long-lasting
cables. These requirements are met to a high degree as is the electromagnetic compatibility (EMC).
These cables can also be used as drag chain cables.
Manufacturing is based on specifications from renowned manufacturers of servo-actuators and servo-controls as well as in accordance with
diverse VDE standards. Application for system SIMODRIVE.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


TOPSERV 110
(1 pair screened and overall screening)
Part no. No.cores x
cross-sec.
mm
71491
( 4 x 1,5 + (2G1,0))
71493
( 4 x 2,5 + (2G1,0))
71705
( 4 x 4 + (2G1,0))
71706
( 4 x 6 + (2G1,0))
71707
( 4 x 10 + (2G1,0))
71708
( 4 x 16 + (2G1,0))
71709
( 4 x 25 + (2G1,0))
71710
( 4 x 35 + (2G1,0))
71711
( 4 x 50 + (2G1,0))

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
11,5
139,0
211,0
13,6
188,0
273,0
14,6
260,0
352,0
16,0
360,0
500,0
20,2
590,0
753,0
23,8
845,0
1061,0
27,0
1320,0
1499,0
31,9
1840,0
1992,0
36,7
2530,0
2880,0

AWG-No.
16
14
12
10
8
6
4
2
1

TOPSERV 120
(2 pairs individually screened and overall screening)
Part no. No.cores x
cross-sec.
mm
71990
( 4 x 1,5 + 2 x (2G1,0))
71991
( 4 x 2,5 + 2 x (2G1,0))
71992
( 4 x 4 + 2 x (2G1,0))
71993
( 4 x 6 + 2 x (2G1,0))
71994
( 4 x 10 + 2 x (2G1,0))
71995
( 4 x 16 + 2 x (2G1,0))
71996
( 4 x 25 + 2 x (2G1,0))
72106
( 4 x 35 + 2 x (2G1,0))
71997
( 4 x 50 + 2 x (2G1,0))

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
12,6
186,0
242,0
15,0
231,0
316,0
16,0
308,0
415,0
18,2
420,0
574,0
22,8
647,0
805,0
25,0
918,0
1122,0
27,7
1400,0
1584,0
32,0
1882,0
2185,0
37,0
2574,0
2977,0

AWG-No.
16
14
12
10
8
6
4
2
1

TOPSERV Feedback-Cable (overall braid-screened)


Part no. No.cores x
cross-sec.
mm
72042
( 12 x 0,25)
71492
( 3 x (2 x 0,14) + 4 x 0,14 + 4 x
0,25 + 2 x 0,5)
72043
( 4 x 2 x 0,34 + 4 x 0,5)

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
7,5
49,0
90,0
10,7
92,0
145,0
9,5

77,0

AWG-No.

144,0

Cable structure
(deviation from TOPSERV)

24
-

PVC-core insulation, Cores colour coded, Foil taped, PUR-jacket


TPE-core insulation, Cores colour coded, Fleece wrapping, PUR-jacket

22

PVC-core insulation, Cores colour coded, Foil taped, PUR-jacket

Dimensions and specifications may be changed without prior notice. (RD01)

D9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Tachofeedback-Cable-C-PVC, Incremental
feedback-cable-C-PVC EMC-preferred type, meter marking


D


Technical data

Cable structure

Properties

Special core and sheath compound from


PVC
Temperature range
flexing -5 C to +70 C
fixed installation -30 C to +80 C
Nominal voltage
Tachofeedback-cable-C-PVC
450 V
Increm. feedback-cable-C-PVC
250 V
Test voltage
core/core 2000 V
core/screen 1000 V
Breakdown voltage
min. 4000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
10x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, fine wire conductor to


DINVDE0295 cl.5, BS6360 cl.5 and/or
IEC60228 cl.5
Special PVC core insulation
Colour code
Tachofeedback-cable:
blue, white, red, pink, green, yellow, brown,
black, grey
Incremental feedback-cable:
brown, black/red, green/light-brown,
white, pink/grey, violet/blue
Single cores or pairs stranded in layer with
optimal lay-length pairs part no.22825)
Core wrapping with film
Drain wire
Tinned copper braided screening, coverage
approx. 85%
Special PVC outer sheath
Colour grey (RAL7001)
with meter marking, change-over in 2011


Extensively oil resistant, foroil-/ chemical


Resistance see Techn. Information table
PVC self-extinguishing and flame resistant
to VDE0482 part265-2-1/ EN50265-2-1/
IEC60332-1 (equivalent to DINVDE0472
part804 test typeB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Application
Both cables fulfil differing tasks for the control of servo-motors.
The tachofeedback-cable or response cable serves the regulation of the motor speed and measurement of the actual values.
The incremental feedback-cable or position response cable transfers the control signals for positioning and engineering characteristics and
is used as the flexible connecting cable for tachometer, brakes, pulse transmitter in system and mechanical engineering, in dry, damp and
wet environments.
EMC = Electromagnetic compatibility
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Tachofeedback-Cable
Part no. No.cores x
cross-sec.
mm
22824
( 9 x 0,5)

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
8,8
81,0
150,0

AWG-No.
20

Incremental feedback-cable
Part no. No.cores x
cross-sec.
mm
22825
( 4 x 2 x 0,25 + 2 x 1,0)

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
8,8
66,0
110,0

AWG-No.
24

Dimensions and specifications may be changed without prior notice. (RD01)

D 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Tachofeedback-Cable-C-PUR, Incremental
feedback-cable-C-PUR drag chain cable, EMC-preferred type, meter
marking


Technical data

Cable structure

Properties

Special core and sheath compound of


TPE-E/PUR
Temperature range
flexing -30 C to +80 C
fixed installation -50 C to +80 C
Nominal voltage
Tachofeedback-cable-C-PUR = 450 V
Incremental feedback-cable-C-PUR
= 250 V
Test voltage
core/core 2000 V
core/screen 1000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing approx. 10x cable
fixed installation approx. 5x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, ultra-fine wire conductors


acc. to DINVDE0295 cl.6, BS6360 cl.6
and/or IEC60228 cl.6
TPE-core insulation
Colour code
Tachofeedback-cable:
blue, white, red, pink, green, yellow, brown,
black, grey
Incremental feedback-cable:
brown (1mm), black/red,
green/light-brown (1mm), white,
pink/grey, violet/blue
Single cores or pairs stranded in layer with
optimal lay-length pairs part no.22818)
Fleece wrapping
Drain wire
Tinned copper braided screening, coverage
approx. 85%
Special PUR (polyurethane) outer sheath
matt
Sheath colour orange (RAL2003)
with meter marking, change-over in 2011


Special PUR outer sheath low adhesion and


flame retardant
Resistant to
Oils and fats
Acids and alkalis
Hydraulic fluids
Oxygen and ozone
UV-radiation
Hydrolysis
Microbial attack
Water and weathering effects
The high abrasion resistance and notch
resistance meet the highest requirements
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

For extreme applications extending beyond


standard solutions we recommend that
you request our questionnaire, which has
been especially designed for energy supply
systems.
Please observe applicable installation
regulations for use in energy supply chains.

Application
Both cables fulfil differing tasks for the control of servo-motors.
The tachofeedback-cable or response cable serves the regulation of the motor speed and measurement of the actual values.
The incremental feedback-cable or position response cable transfers the control signals for positioning and engineering characteristics and
is used as the flexible connecting cable for tachometer, brakes and pulse transmitter in case of high mechanical stress in plant, machine
and control engineering in dry, moist and wet rooms. Particularly suitable for continuous operating in drag chains, industrial robotics and
handling equipment as these cables enable an excellent transmission of data and signals. Additional cores for the power supply to individual
components are available. The braided screen guarantees reliable signal transmission. Optimum functionality, long service life and an excellent
cost-performance ratio are given for the mentioned applications by the special compounds used for insulation and sheath.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Tachofeedback-cable
Part no. No.cores x
cross-sec.
mm
22823
( 9 x 0,5)

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
8,8
80,8
128,0

AWG-No.
20

Incremental feedback cable


Part no. No.cores x
cross-sec.
mm
22818
( 4 x 2 x 0,25 + 2 x 1,0)

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
8,8
65,2
105,0

AWG-No.
24

Dimensions and specifications may be changed without prior notice. (RD01)

D 11
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX 240-PVC / 240-PUR special measuring and data cable,


EMC-preferred type, meter marking


D


Technical data

Cable structure

Properties

Special core and sheath compound from


PVC
Core resistance at 20 C
0,38 mm max. 47 Ohm/km
0,50 mm max. 36 Ohm/km
Temperature range
flexing -10 C to +70 C
fixed installation -30 C to +80 C
Nominal voltage 500 V
Test voltage
core/core 2000 V
core/screen 1000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
approx. 10x cable
Coupling resistance
max. 250 Ohm/km

TOPFLEX 240-PVC
Tinned copper conductor
0,38 mm 19x0,16 mm
0,50 mm 28x0,15 mm
PVC core insulation
Cores stranded in pairs with optimal
lay-length
Film wrap
Pairs stranded in layers with optimal
lay-length
Tinned copper braided screening, coverage
approx. 85%
PVC outer sheath
Sheath colour grey (RAL 7000)
with meter marking, change-over in 2011
TOPFLEX240-PUR
Highly-flexible copper wire stranding
PUR-outer sheath
Sheath colour orange (RAL 2003)
with meter marking, change-over in 2011


PVC-outer sheath largely oil resistant, for


oil-/chemical Resistance see Technical
Information table
PUR-outer sheath particularly resistant
to oil alkali as well as tear and abrasion
proof
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

Colour code No. 1 (Standard)


0,38 mm: orange/red violet/blue
brown/black yellow/green
0,50 mm: brown/black yellow/red
Colour code No. 2 (alternative)
0,38 mm: orange/red violet/blue
brown/black yellow/grey
0,50 mm: brown/black yellow/red
Colour-code No. 3 (to DIN 47100)
0,38 mm: white/brown green/yellow
grey/pink blue/red
0,50 mm: black/violet grey-pink/red-blue

Application
TOPFLEX 240-PVC
Used as a data and electronics cable in machines, plant installation, conveyor systems etc.
TOPFLEX 240-PUR
This cable type is available in the following types for use under extreme conditions in machine and plant engineering.
EMC = Electromagnetic compatibility
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


TOPFLEX 240-PVC grey


Part
no.
22801
22891
22890

Col.
code
no.
1
3
2

No.cores x
cross-sec.
mm
4 x 2 x 0,38 + 4 x 0,5
4 x 2 x 0,38 + 4 x 0,5
4 x 2 x 0,38 + 4 x 0,5

Outer Cop.
Weight AWG-No.
approx. weight approx.
mm
kg/km kg/km
10,5
77,0
125,0
21
10,5
77,0
125,0
21
10,5
77,0
125,0
21

TOPFLEX 240-PUR orange


Part
no.
22827
22892

Col.
code
no.
1
2

No.cores x
cross-sec.
mm
4 x 2 x 0,38 + 4 x 0,5
4 x 2 x 0,38 + 4 x 0,5

Outer Cop.
Weight AWG-No.
approx. weight approx.
mm
kg/km kg/km
10,9
77,0
135,0
21
10,9
77,0
135,0
21

Dimensions and specifications may be changed without prior notice. (RD01)

D 12
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX-PVC feedback cable, EMC-preferred type, meter marking




Technical data

Cable structure

Properties

Special core and sheath compound from


PVC
Temperature range
flexing -5 C to +70 C
fixed installation -30 C to +80 C
Nominal voltage 350 V
Test voltage
core/core 2000 V
core/screen 1000 V
Breakdown voltage
min. 4000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
10x cable
Coupling resistance
max. 250 Ohm/km

Bare copper, fine and/or ultra-fine wire


conductors acc. to DINVDE0295 cl.5,
BS6360 cl.5 and/or IEC60228
PVC core insulation
Cores colour coded according to DIN47100
Cores stranded in layers with optimal
lay-length
Core wrapping with film
Tinned copper braided screening, coverage
approx. 85%
Special PVC outer sheath
Colour grey (RAL 7001)
with meter marking, change-over in 2011
Colour code for cores
Part no. / Core / colours
22845 / 10x0,14 / to DIN 47100
22845 / 2x0,5 / white, brown
22846 / 10x0,14 / to DIN 47100
22846 / 4x0,5 / white, brown, green, yellow
22820 / 15x0,14 / to DIN 47100
22820 / 4x0,5 / white, brown, green, yellow


Largely oil-resistant, for oil-/chemical


Resistance see Technical Information table
PVC self-extinguishing and flame resistant
to VDE0482 part265-2-1/ EN50265-2-1/
IEC60332-1 (equivalent to DINVDE0472
part804 test typeB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Application
These feedback cables are used in machinery and control construction as well as in plant engineering as these enable an excellent transmission
of data and signals. Additional cores for the power supply to individual components are available.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.cores x


cross-sec.
mm
22845
( 10 x 0,14 + 2 x 0,5)
22846
( 10 x 0,14 + 4 x 0,5)

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
8,0
46,2
70,0
8,2
56,3
86,0

AWG-No.
26
26


Part no. No.cores x
cross-sec.
mm
22820
( 15 x 0,14 + 4 x 0,5)

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
8,7
59,0
123,0

AWG-No.
26

Dimensions and specifications may be changed without prior notice. (RD01)

D 13
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX-PUR drag chain feedback cable, EMC-preferred type, halogen-free,


meter marking


D


Technical data

Cable structure

Properties

Special core and sheath compound from


PUR
Temperature range
flexing -30 C to +80 C
Nominal voltage 350 V
Test voltage
core/core 2000 V
core/screen 1000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing approx. 10x cable
fixed installation approx. 5x cable
Coupling resistance
max. 250 Ohm/km

Bare copper, fine and/or ultra-fine wire


conductors acc. to DINVDE0295, BS6360
and/or IEC60228
TPE-core insulation
Cores colour coded according to DIN47100
Cores stranded in layers with optimal
lay-length
Common fleece wrapping
Tinned copper braided screening, coverage
approx. 85%
Special PUR outer sheath
Sheath colour grey (RAL7001)
with meter marking, change-over in 2011


PUR outer sheath, low adhesion, notch


resistant
The outer sheath on the basis of PUR is
adhesion-free, flame retardant and
resistant to hydrolysis and microbial attack
The high abrasion resistance and notch
resistance meet the highest requirements


Note

For extreme applications extending beyond


standard solutions we recommend that
you request our questionnaire, which has
been especially designed for energy supply
systems.
Please observe applicable installation
regulations for use in energy supply chains.


Application
These feedback-cables are used in machinery and control construction as well as in plant engineering as these enable an excellent transmission
of data and signals.
Particularly suitable in power drag chains, robotics and handling equipment. Additional cores for the power supply to individual components
are available. The braided screen guarantees reliable signal transmission.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
22849
( 10 x 0,14 + 2 x 0,5)
22848
( 10 x 0,14 + 4 x 0,5)

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
7,2
39,0
83,0
7,7
54,3
96,0

AWG-No.
26
26


Part no. No.cores x
cross-sec.
mm
22834
( 15 x 0,14 + 4 x 0,5)

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
7,9
58,0
120,0

AWG-No.
26

Dimensions and specifications may be changed without prior notice. (RD01)

D 14
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX-PVC feedback cable, EMC-preferred type, meter marking




Technical data

Cable structure

Properties

Special core and sheath compound


Temperature range
flexing -5 C to +70 C
fixed installation -30 C to +80 C
Nominal voltage 350 V
Test voltage
core/core 2000 V
core/screen 1000 V
Breakdown voltage
min. 4000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
10x cable
Coupling resistance
max. 250 Ohm/km

Copper, fine and/or ultra-fine wire


conductors acc. to DINVDE0295, BS 6360
and/or IEC60228
PVC core insulation
Cores colour coded1) Cores or pairs
stranded in layers with optimal lay-length
Design includes
Cu screen of single pairs or single cores
and PVC-insulated sheath
Common film wrapping
Tinned copper braided screening, coverage
approx. 85%
Special PVC outer sheath
Sheath colour grey (RAL 7001)
with meter marking, change-over in 2011
Colour code for cores
Part no./Core/colours
22800 / 0,14 / gn/ye, gy/pk, bu/rd
22802 / 0,14 / gn/ye, gy/pk, bu/rd
22803 / 0,14 / gn/gy, pk/rd, bn/bk
22806 / 0,14 / rd/bk, bn/gn, ye/vt,gy/pk
22800 / 0,5 / wh, bn
22802 / 0,5 / wh, bn
22803 / 0,5 / wh, bu, whgn, bngn
22806 / 0,5 / wh, bu, whgn, bngn


Largely oil-resistant, for oil-/ chemical


Resistance see Technical Information table
PVC self-extinguishing and flame resistant
to VDE0482 part265-2-1/ EN50265-2-1/
IEC60332-1 (equivalent to DINVDE0472
part804 test typeB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Application
These feedback-cables are used in machinery and control construction as well as in plant engineering as these enable an excellent transmission
of data and signals. Additional cores for the power supply to individual components are available.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.cores x


cross-sec.
mm
22800
( 3 x (2 x 0,14) + (2 x 0,5))
22802
( 3 x (2 x 0,14) + (2 x 0,5))

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
8,5
78,0
112,0
8,5
72,0
108,0

AWG-No.
26
26


Part no. No.cores x
cross-sec.
mm
22803
( 3 x 2 x 0,14 + 4 x 0,5)
22806
( 4 x 2 x 0,14 + 4 x 0,5)

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
8,5
66,0
98,0
8,5
68,0
111,0

AWG-No.
26
26

Dimensions and specifications may be changed without prior notice. (RD01)

D 15
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX-PUR drag chain feedback cable, EMC-preferred type, halogen-free,


meter marking


D


Technical data

Cable structure

Properties

Special core and sheath compound


Temperature range
flexing -30 C to +80 C
fixed installation -50 C to +80 C
Nominal voltage 350 V
Test voltage
core/core 2000 V
core/screen 1000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing approx. 10x cable
fixed installation approx. 5x cable
Coupling resistance
max. 250 Ohm/km
Radiation-resistance
up to 50x106 cJ/kg (up to 50 Mrad)

Bare copper, ultra-fine wire conductor to


DINVDE0295 cl.6, BS6360 cl.6 and/or
IEC60228 cl.6
TPE-core insulation
Cores colour coded
Adern adrig bzw. paarig mit optimalen
Schlaglngen in Lagen verseilt
Design includes Cu screen of single pairs
or single cores and PETP (polyethylene
terephthalate) sheath
Fleece wrapping
Tinned copper braided screening, coverage
approx. 85%
PUR outer sheath, matt
Sheath colour grey (RAL 7001)
with meter marking, change-over in 2011
Colour code for cores
Part no./Core/colours
22847 / 0,14 / to DIN 47100 from green
22850 / 0,14 / to DIN 47100 from green
22851 / 0,14 / gn/ye, gy/pk, rd/bu
22852 / 0,14 / bn/gn, ye/vt, gy/pk,rt/bu
22853 / 0,25 / rd/bk, bn/gn, gy/pk,bu/vt
22847 / 0,5 / wh, bn
22850 / 0,5 / wh, bn
22851 / 0,5 / wh, bn
22852 / 0,5 / wh, bu, whgn, bngn
22853 / 0,5 / wh, bn


PUR outer sheath is adhesion-free, flame


retardant and resistant to hydrolysis and
microbial attack.
The high abrasion resistance and notch
resistance meet the highest requirements
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

For extreme applications extending beyond


standard solutions we recommend that
you request our questionnaire, which has
been especially designed for energy supply
systems.
Art.-No. 22847 diameter of conductor 0,5
mm per core screened
Please observe applicable installation
regulations for use in energy supply chains.


Application
These feedback-cables are used in machinery and control construction as well as in plant engineering as these enable an excellent transmission
of data and signals, e.g. in energy management chains, robotics and handling equipment. Additional cores for the power supply to individual
components are available. The braided screen guarantees reliable signal transmission.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
22847
( 3 x ( 2 x 0,14 ) + 2 x (0,5) )
22850
( 3 x (2 x 0,14) + 2 x 0,5)
22851
( 3 x (2 x 0,14) + 2 x 0,5)

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
8,3
78,0
103,0
8,0
72,0
102,0
8,4
72,0
105,0

AWG-No.
26
26
26


Part no. No.cores x
cross-sec.
mm
22852
4 x 2 x 0,14 + 4 x 0,5
22853
4 x 2 x 0,25 + 2 x 0,5

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
8,4
73,0
105,0
8,6
77,0
125,0

AWG-No.
26
24

Dimensions and specifications may be changed without prior notice. (RD01)

D 16
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX -EMV-2YSLCY-J for power supply connections to frequency


converters, double screened, 0,6/1kV, meter marking


Technical data

Cable structure

Properties

Special motor power supply cable for


frequency converters adapted to
DINVDE0250
Temperature range
flexing +5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage U0/U 600/1000 V
Max. operating voltage
A.C. and 3-phase 700/1200 V
DC operation 900/1800 V
Test voltage 2500 V
Insulation resistance
min. 200 MOhm x km
Coupling resistance
according to different cross-sections
max. 250 Ohm/km
Mutual capacitance
according to different cross-sections
core/core 70 to 250 nF/km
core/screen 110 to 410 nF/km
Minimum bending radius
fixed installation for outer :
up to 12 mm: approx. 5x cable
>12 to 20 mm: approx. 7,5x cable
>20 mm: approx. 10x cable
free-movement for outer:
up to 12 mm: approx. 10x cable
>12 to 20 mm: approx. 15x cable
>20 mm: approx. 20x cable
Radiation-resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductor to


DINVDE0295 cl.5, BS6360 cl.5 or
IEC60228 cl.5
Polyethylene (PE) core insulation
Core colours: green-yellow, brown, black,
grey
Cores stranded in concentric layers
1. screening with special aluminum foil
2. screening with copper braiding, tinned
copper, coverage approx. 80%
Transparent special PVC outer sheath
with meter marking, change-over in 2011



Behavior in fire: Test according to


VDE0482-332-1-2, DIN EN60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Low mutual capacitance, to DINVDE0472
part504, test methodB
Features PE-insulation secures a lower
dielectric loss, double potential strength,
high longevity and low screen-interference
currents
Installation in hazardous areas
Low mutual capacitance
Meets EMC requirements according to
EN55011 and DINVDE0875 part11
Low coupling resistance for high
electromagnetic compatibility
This screened motor supply cable with low
mutual capacitance of the single cores
because of the special PE core insulation
and low screen capacitance enable a
low-loss transmission of the power
compared to PVC-sheathed connecting
cables
Due to the optimal screening an
interference-free operation of frequency
converters is obtained
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core.


The current carrying capacity for
permanent operation at ambient
temperature of
30 C. For deviating ambient temperatures
the conversion factors should be used and
for further see the indication in
DINVDE0298 part4

Application
This TOPFLEX-EMV-2YSLCY-J motor power supply cable for the frequency converters assures electromagnetic compatibility in plants and
buildings, facilities with units and operating equipment where the fields of electromagnetic interference might cause adverse effects on
the surroundings. As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry,
moist and wet environments, not however for outdoor applications. Used in the automotive and food industries, environmental technology,
packaging industry, machine tools.
Handling equipment, for SIMOVERT drives, they are particularly suitable for use with industrial pumps, ventilators, conveyor belts and
air-conditioning installations and similar applications.
EMC = Electromagnetic compatibility
The screen must be connected at both ends and ensure lare-area contact over the entire cable circumference for compliance with the
functional interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
22084
22085
22086
22087

4G1,5
4G2,5
4G4
4G6

Outer
Mutual capacitance
approx. mm Core / Core Core / Screen
approx. nF / approx. nF /
km
km
10,3
70
110
12,3
80
130
13,9
90
150
15,3
90
150

Coupling resistance
at 1 MHz
at 30 MHz
Ohm/km
Ohm/km

Power ratings **)


with 3 loaded cores
inAmperes

Cop.
weight
kg/km

Weight
approx.
kg/km

18
11
6

18
26
34
44

95,0
150,0
235,0
320,0

230,0
300,0
485,0
633,0

210
210
150

AWG-No.

16
14
12
10

Continuation

D 17
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX -EMV-2YSLCY-J for power supply connections to frequency


converters, double screened, 0,6/1kV, meter marking


Part no. No.cores x


cross-sec.
mm
22088
22089
22090
22091
22092
22093
22094
22095
22096
22097

4G10
4G16
4G25
4G35
4G50
4G70
4G95
4G120
4G150
4G185

Outer
Mutual capacitance
approx. mm Core / Core Core / Screen
approx. nF / approx. nF /
km
km
19,5
120
200
23,3
140
230
27,4
120
210
30,3
150
260
35,5
190
320
40,2
190
320
44,5
250
410
50,3
56,1
58,0

Coupling resistance
at 1 MHz
at 30 MHz
Ohm/km
Ohm/km

Power ratings **)


with 3 loaded cores
inAmperes

Cop.
weight
kg/km

Weight
approx.
kg/km

7
9
4
3
2
2
1

61
82
108
135
168
207
250
292
335
382

533,0
789,0
1236,0
1662,0
2345,0
3196,0
4316,0
5435,0
6394,0
7639,0

863,0
1291,0
1862,0
2611,0
2955,0
3953,0
5304,0
6604,0
7043,0
8384,0

180
190
95
85
40
45
50

AWG-No.

8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil

Dimensions and specifications may be changed without prior notice. (RD01)

Large cabling machine with backtwist at our Windsbach factory.

D 18
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX -EMV-UV-2YSLCYK-J for power supply connections


to frequency converters, double screened, 0,6/1kV, meter marking


Technical data

Cable structure

Properties

Special motor power supply cable for


frequency converters adapted to
DINVDE0250
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage U0/U 600/1000 V
Max. operating voltage
A.C. and 3-phase 700/1200 V
DC operation 900/1800 V
Test voltage 2500 V
Insulation resistance
min. 200 MOhm x km
Coupling resistance
according to different cross-sections
max. 250 Ohm/km
Mutual capacitance
according to different cross-sections
core/core 70 to 250 nF/km
core/screen 110 to 410 nF/km
Minimum bending radius
fixed installation for outer :
up to 12 mm: approx. 5x cable
>12 to 20 mm: approx. 7,5x cable
>20 mm: approx. 10x cable
free-movement for outer :
up to 12 mm: approx. 10x cable
>12 to 20 mm: approx. 15x cable
>20 mm: approx. 20x cable
Radiation-resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductor to


DINVDE0295 cl.5, BS6360 cl.5 or
IEC60228 cl.5
Polyethylene (PE) core insulation
Core colours: green-yellow, brown, black,
grey
Cores stranded in concentric layers
1. screening with special aluminium film
2. screening with copper braiding, tinned
copper, coverage approx. 80%
Special PVC outer sheath, black (RAL9005)
with meter marking, change-over in 2011



Behavior in fire: Test according to


VDE0482-332-1-2, DIN EN60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Low mutual capacitance, to DINVDE0472
part504, test methodB
Features PE-insulation secures a lower
dielectric loss, double potential strength,
high longevity and low screen-interference
currents
Low mutual capacitance
Meets EMC requirements according to
EN55011 and DINVDE0875 part11
Low coupling resistance for high
electromagnetic compatibility
UV-resitant
Outdoor application, possible for
installation in undergroundat 4G16mm
This screened motor supply cable with low
mutual capacitance of the single cores
because of the special PE core insulation
and low screen capacitance enable a
low-loss transmission of the power
compared to PVC-sheathed connecting
cables
Due to the optimal screening an
interference-free operation of frequency
converters is obtained
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

The current carrying capacity for permanent


operation at ambient temperature of
30 C. For deviating ambient temperatures
the conversion factors should be used and
for further see the indication in DINVDE0298
part4

Application
This TOPFLEX-EMC-2YSLCYK-J motor power supply cable for the frequency converters assures electromagnetic compatibility in plants and
buildings, facilities with units and operating equipment where the fields of electromagnetic interference might cause adverse effects on
the surroundings. As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry,
moist and wet environments and for outdoor applications, possible for installation in underground at 4G16 mm.Used in the automotive
and food industries, environmental technology, packaging industry, machine tools. Handling equipment, for SIMOVERT drives, they are
particularly suitable for use with industrial pumps, ventilators, conveyor belts and air-conditioning installations and similar applications.
Installation in hazardous areas.
EMC = Electromagnetic compatibility
The screen must be connected at both ends and ensure lare-area contact over the entire cable circumference for compliance with the
functional interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
22234
22235
22236
22237
22238
22239

4G1,5
4G2,5
4G4
4G6
4G10
4G16

Outer
Mutual capacitance
approx. mm Core / Core Core / Screen
approx. nF / approx. nF /
km
km
10,3
70
110
12,3
80
130
13,9
90
150
15,3
90
150
19,5
120
200
23,3
140
230

Coupling resistance
at 1 MHz
at 30 MHz
Ohm/km
Ohm/km

Power ratings **)


with 3 loaded cores
inAmperes

Cop.
weight
kg/km

Weight
approx.
kg/km

18
11
6
7
9

18
26
34
44
61
82

95,0
150,0
235,0
320,0
533,0
789,0

230,0
300,0
485,0
630,0
860,0
1290,0

210
210
150
180
190

AWG-No.

16
14
12
10
8
6

Continuation

D 19
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX -EMV-UV-2YSLCYK-J for power supply connections


to frequency converters, double screened, 0,6/1kV, meter marking

Part no. No.cores x


cross-sec.
mm
22240
22241
22242
22243
22244
22245
22246
22247

4G25
4G35
4G50
4G70
4G95
4G120
4G150
4G185

Outer
Mutual capacitance
approx. mm Core / Core Core / Screen
approx. nF / approx. nF /
km
km
27,4
120
210
30,3
150
260
35,5
190
320
40,2
190
320
44,5
250
410
50,3
56,1
58,0

Coupling resistance
at 1 MHz
at 30 MHz
Ohm/km
Ohm/km

Power ratings **)


with 3 loaded cores
inAmperes

Cop.
weight
kg/km

Weight
approx.
kg/km

4
3
2
2
1

108
135
168
207
250
292
335
382

1236,0
1662,0
2345,0
3196,0
4316,0
5435,0
6394,0
7639,0

1860,0
2610,0
2950,0
3950,0
5300,0
6600,0
7040,0
8380,0

95
85
40
45
50

AWG-No.

4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil

Dimensions and specifications may be changed without prior notice. (RD01)

Tools
Cable shears
Box spanners
Strippers
Crimping tools
Pliers
Skinning knife

You can nd tools in our catalogue Cable Accessories.

D 20
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX-EMV-3 PLUS 2YSLCY-J for power supply connections


to frequency converters, double screened, 0,6/1kV, meter marking


Technical data

Cable structure

Properties

Special motor power supply cable for


frequency converters adapted to
DINVDE0250
Temperature range
flexing +5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage U0/U 600/1000 V
Max. operating voltage
A.C. and 3-phase 700/1200 V
DC operation 900/1800 V
Peak value 1700 V
Test voltage 2500 V
-RWYPEXMSRVIWMWXERGI
min. 200 MOhm x km
Coupling resistance
according to different cross-sections
max. 250 Ohm/km
Minimum bending radius
fixed installation for outer :
up to 12 mm: approx. 5x cable
>12 to 20 mm: approx. 7,5x cable
>20 mm: approx. 10x cable
free-movement for outer :
up to 12 mm: approx. 10x cable
>12 to 20 mm: approx. 15x cable
>20 mm: approx. 20x cable
Radiation-resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Plain copper, fine wire conductor according


to DINVDE0295 cl.5, BS6360 cl.5 and/or
IEC60228 cl.5
Polyethylene (PE) core insulation
Core colours: black, brown, grey,
green-yellow (earth core divided into 3)
3+3-core structure
Cores stranded in concentric layers
1. screening with special aluminium film
2. screening with copper braiding, tinned
copper, coverage approx. 80%
Transparentspecial PVC outer sheath
with meter marking, change-over in 2011
Pos.no. 22380 = capacitance
core/core 270 nF/km
core/screen 520 nF/km



Behavior in fire: Test according to


VDE0482-332-1-2, DIN EN60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
PE-insulation secures a lower dielectric loss,
double potential strength, high longevity
and low screen-interference currents
Application in ex-area
Low mutual capacitance
Meets EMC requirements according to
EN55011 and DINVDE0875 part11
Low coupling resistance for high
electromagnetic compatibility
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
The screen must be connected at both
ends and ensure lare-area contact over the
entire cable circumference for compliance
with the functional interference
requirements of EN55011
The minimum cross-section of 0,75 meets
the requirements of DINEN60204 part1


Note

The current carrying capacity for permanent


operation at ambient temperature of
30 C. For deviating ambient temperatures
the conversion factors should be used and
for further see the indication in DINVDE0298
part4

Application
As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet
environments and for outdoor applications. Used in the automotive and food industries, environmental technology, packaging industry,
machine tools. Handling equipment, for SIMOVERT drives, they are particularly suitable for use with industrial pumps, ventilators, conveyor
belts and air-conditioning installations and similar applications. Installation in hazardous areas
This screened motor supply cable with low mutual capacitance of the single cores because of the special PE core insulation and low screen
capacitance enable a low-loss transmission of the power compared to PVC-sheathed connecting cables.
Due to the optimal screening an interference-free operation of frequency converters is obtained.
EMC = Electromagnetic compatibility
The screen must be connected at both ends and ensure lare-area contact over the entire cable circumference for compliance with the
functional interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
22368
22369
22370
22371
22372
22373
22374

No.cores x
cross-sec.
mm
3 x 1,5 + 3G0,25
3 x 2,5 + 3G0,5
3 x 4 + 3G0,75
3 x 6 + 3G1,0
3 x 10 + 3G1,5
3 x 16 + 3G2,5
3 x 25 + 3G4,0

Outer
approx. mm
9,9
11,3
13,0
14,9
18,4
21,5
25,3

Coupling resistance
at 1 MHz
at 30 MHz
Ohm/km
Ohm/km
18
11
6
7
9
4

210
210
150
180
190
95

Power ratings **)


with 3 loaded cores
inAmperes
18
26
34
44
61
82
108

Cop.
weight
kg/km
86,0
144,0
224,0
298,0
491,0
723,0
1138,0

Weight
approx.
kg/km
140,0
220,0
323,0
420,0
615,0
819,0
1325,0

AWG-No.
16
14
12
10
8
6
4

Continuation

D 21
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX-EMV-3 PLUS 2YSLCY-J for power supply connections


to frequency converters, double screened, 0,6/1kV, meter marking

Part no.
22375
22376
22377
22378
22379
22380
22381
22382

No.cores x
cross-sec.
mm
3 x 35 + 3G6,0
3 x 50 + 3G10,0
3 x 70 + 3G10,0
3 x 95 + 3G16,0
3 x 120 + 3G16,0
3 x 150 + 3G25,0
3 x 185 + 3G35,0
3 x 240 + 3G42,5

Outer
approx. mm
27,8
31,9
36,8
40,6
45,9
51,7
53,8
61,7

Coupling resistance
at 1 MHz
at 30 MHz
Ohm/km
Ohm/km
3
85
2
40
2
45
1
50

Power ratings **)


with 3 loaded cores
inAmperes
135
168
207
250
292
335
382
453

Cop.
weight
kg/km
1535,0
2208,0
2871,0
3953,0
4836,0
5412,0
6969,0
8540,0

Weight
approx.
kg/km
1718,0
2399,0
3056,0
4162,0
5074,0
6128,0
7189,0
9540,0

AWG-No.
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil

Dimensions and specifications may be changed without prior notice. (RD01)

Signal and power circular connectors


Series A, B, C, D, F and S
Tools
Accessories
Online congurator
Pre-assembled cables

You can nd signal and power circular connectors in our catalogue Cable Accessories.

D 22
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J for power supply


connections to frequency converters, double screened, 0,6/1kV, meter marking


Technical data

Cable structure

Properties

Special motor power supply cable for


frequency converters adapted to
DINVDE0250
Temperature range
flexing -5 C bis +70 C
fixed installation -40 C bis +70 C
Nominal voltage U0/U 600/1000 V
Operating voltage, max.
A.C. and 3-phase 700/1200 V
DC operation 900/1800 V
Peak value 1700 V
Test voltage 2500 V
Insulation resistance
min. 200 MOhm x km
Coupling resistance
depending on the cross-section
max. 250 Ohm/km
Minimum bending radius
fixed installation for outer :
up to 12 mm: 5x cable
>12 to 20 mm: 7,5x cable
>20 mm: 10x cable
free-movement for outer :
up to 12 mm: 10x cable
>12 to 20 mm: 15x cable
>20 mm: 20x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductor to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Polyethylene (PE) core insulation
Core colour: black, brown, grey,
green-yellow (earth core divided into 3)
Cores stranded in concentric layers
3+3 core design
1. screening with special aluminum foil
2. screening with copper braiding, tinned
copper, coverage approx. 80%
Special PVC outer sheath, schwarz (RAL
9005)
with meter marking, change-over in 2011
Pos.no. 22685 = capacitance
core/core 270 nF/km
core/screen 520 nF/km



Behavior in fire: Test according to


VDE0482-332-1-2, DIN EN60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Low mutual capacitance, test according to
DIN VDE 0472 part 504, test method B
PE-insulation secures a lower dielectric loss,
double potential strength, high longevity
and low screen-interference currents
Low mutual capacitance
Meets EMC requirements according to
EN55011 and DINVDE0875 part11
Low coupling resistance for high
electromagnetic compatibility
Due to the optimal screening an
interference-free operation of frequency
converters is obtained
The 3 Plus-construction of motor power
supply cables features a symmetrical 3-core
design, improved in terms of EMC
characteristics comparing favorably with a
4-core version. The protective conductor
PE, divided into 3 is uniformly stranded in
the interstices. This enables an extremely
concentric structure
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
The minimum cross-section of 0,75 meets
the requirements of DINEN60204 part1
UV-resistant
Outdoor application 
This screened motor supply cable with low
mutual capacitance of the single cores
because of the special PE core insulation
and low screen capacitance enable a
low-loss transmission of the power
compared to PVC-sheathed connecting
cables


Note

The current carrying capacity for permanent


operation at ambient temperature of
30 C. For deviating ambient temperatures
the conversion factors should be used and
for further see the indication in DINVDE0298
part4

Application
As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet
environments and for outdoor applications, possible for installation inunderground at 3x16+3G2,5 mm. Used in the automobile industry,
food industry, environmental engineering, packaging industry, toolmaking machinery, handling equipment, for SIMOVERT drivers, they are
particularly suitable for use with industrial pumps, ventilators, conveyor belts and air-conditioning installations and similar applications.
Installation in hazardous areas.
EMC = Electromagnetic compatibility
The screen must be connected at both ends and ensure lare-area contact over the entire cable circumference for compliance with the
functional interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Continuation

D 23
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J for power supply


connections to frequency converters, double screened, 0,6/1kV, meter marking

Part no.
22673
22674
22675
22676
22677
22678
22679
22680
22681
22682
22683
22684
22685
22686
22687

No.cores x
cross-sec.
mm
3 x 1,5 + 3G0,25
3 x 2,5 + 3G0,5
3 x 4 + 3G0,75
3 x 6 + 3G1,0
3 x 10 + 3G1,5
3 x 16 + 3G2,5
3 x 25 + 3G4,0
3 x 35 + 3G6,0
3 x 50 + 3G10,0
3 x 70 + 3G10,0
3 x 95 + 3G16,0
3 x 120 + 3G16,0
3 x 150 + 3G25,0
3 x 185 + 3G35,0
3 x 240 + 3G42,5

Outer
approx. mm
9,9
11,3
13,0
14,9
18,4
21,5
25,3
27,8
31,9
36,8
40,6
45,9
51,7
53,8
61,7

Coupling resistance
at 1 MHz
at 30 MHz
Ohm/km
Ohm/km
18
11
6
7
9
4
3
2
2
1

210
210
150
180
190
95
85
40
45
50

Power ratings **)


with 3 loaded cores
inAmperes
18
26
34
44
61
82
108
135
168
207
250
292
335
382

Cop.
weight
kg/km
86,0
144,0
224,0
298,0
491,0
723,0
1138,0
1535,0
2208,0
2871,0
3953,0
4836,0
5412,0
6969,0
8540,0

Weight
approx.
kg/km
140,0
220,0
323,0
420,0
615,0
819,0
1325,0
1718,0
2399,0
3056,0
4162,0
5075,0
6128,0
7189,0
9540,0

AWG-No.
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil

Dimensions and specifications may be changed without prior notice. (RD01)

Cable Glands
Cable glands for standard applications
Plastic Glands
Cable Glands of Brass
Accessories
Cable glands for special application conditions
for electromagnetic compatibility EMC
for rugged applications and special chemical resistance
for high temperature use
for explosive areas
for special mounting conditions
for special pressure conditions

You can nd cable glands in our catalogue Cable Accessories.

D 24
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX Motor 109 low capacitance power supply cable 0,6/1kV,


increased ampacity, halogen-free, meter marking


Technical data

Cable structure

Properties

Special motor power supply cable for


frequency converters
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +80 C
4IVQMWWMFPIoperating temperature
at conductor +90 C
Nominal voltage U0/U 600/1000 V
Max. operating voltage
A.C. and 3-phase 700/1200 V
DC operation 900/1800 V
Test voltage 2500 V
Insulation resistance
min. 200 MOhm x km
Coupling resistance
according to different cross-sections
max. 250 Ohm/km
Mutual capacitance
according to different cross-sections
core/core 70 to 250 nF/km
core/screen 110 to 410 nF/km
Minimum bending radius
fixed installation for outer :
up to 12 mm: approx. 5x cable
>12 to 20 mm: approx. 7,5x cable
>20 mm: approx. 10x cable
free-movement for outer :
up to 12 mm: approx. 10x cable
>12 to 20 mm: approx. 15x cable
>20 mm: approx. 20x cable
Radiation-resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductor to


DINVDE0295 cl.5, BS6360 cl.5 or
IEC60228 cl.5
Special-Polymer core insulation
Cores coded to DIN VDE 0293-308
Core colours:
above 5 cores color coded
7 cores black with numbering
Green-yellow earth-core
Cores stranded in concentric layers
1. screening with special aluminium film
2. screening with copper braiding, tinned
copper, coverage approx. 80%
Special PUR outer sheath, orange
(RAL2003)
with meter marking, change-over in 2011


PUR behavior in fire: Test according to


VDE0482-332-1-2, DIN EN60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Low mutual capacitance, test accordingto
DINVDE0472 part504, test methodB
Special polymerinsulation ensures low
dielectric losses, a dual voltage resistance,
longer service life and low - interference
shield, and increased current carrying
capacity
Meets EMC requirements according to
EN55011 and DINVDE0875 part11
Low coupling resistance for high
electromagnetic compatibility
UV-resistant
Outdoor application
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
This screened motor supply cable with low
mutual capacitance of the single cores
because of the special Polymer core
insulation and low screen capacitance
enable a low-loss transmission of the power
compared to PVC-sheathed connecting
cables
Due to the optimal screening an
interference-free operation of frequency
converters is obtained
Design according to the requirements of
VdS 3501:2006-04

Application
This motor power supply cable for the frequency converters assures electromagnetic compatibility in plants and buildings, facilities with
units and operating equipment where the fields of electromagnetic interference might cause adverse effects on the surroundings. As a
supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments
and for outdoor applications. Used in the automotive and food industries, environmental technology, packaging industry, machine tools.
Handling equipment, for SIMOVERT drives, they are particularly suitable for use with industrial pumps, ventilators, conveyor belts and
air-conditioning installations and similar applications.
Installation in hazardous areas.
EMC = Electromagnetic compatibility
The screen must be connected at both ends and ensure lare-area contact over the entire cable circumference for compliance with the
functional interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.cores x


cross-sec.
mm
22724
3G1,5
22707
4G1,5
22708
5G1,5
22709
7G1,5
22710
3G2,5
22711
4G2,5

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
9,4
72,0
200,0
10,4
95,0
230,0
11,2
117,0
258,0
13,2
148,0
281,0
11,2
137,0
270,0
12,5
150,0
300,0

AWG-No.
16
16
16
16
16
16


Part no. No.cores x
cross-sec.
mm
22712
5G2,5
22713
7G2,5
22714
4G4
22715
5G4
22716
7G4
22717
4G6

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
13,5
200,0
352,0
16,0
230,0
473,0
14,2
235,0
485,0
15,4
321,0
567,0
18,2
352,0
603,0
15,2
320,0
633,0

AWG-No.
16
16
16
16
16
16

Continuation

D 25
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX Motor 109 low capacitance power supply cable 0,6/1kV,


increased ampacity, halogen-free, meter marking

Part no. No.cores x


cross-sec.
mm
22718
5G6
22719
7G6
22720
4G10

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
16,8
439,0
679,0
20,0
501,0
771,0
19,5
533,0
860,0

AWG-No.
16
16
16

Part no. No.cores x


cross-sec.
mm
22721
5G10
22722
4G16
22723
4G25

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
21,6
711,0
1029,0
23,1
789,0
1290,0
27,1
1236,0
1862,0

AWG-No.
16
16
16

Dimensions and specifications may be changed without prior notice. (RD01)

Drag Chain Systems


Open chains
Closed chains
Accessories
Installation instructions
Selection tables

You can nd drag chain systems in our catalogue Cable Accessories.

D 26
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Heat-resistant Cables

E1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Heat-resistant Cables
High or low temperatures and permanent
temperature changes demand cable types with
special core and sheath insulation depending on
the different applications.

HELUKABEL supply these indispensable special


cables which are used in power stations, iron
works, steelworks and rolling mill, in foundries,
cement, glass and ceramic factories. They are also
used in aircraft construction and shipbuilding, in
brickworks, kitchen appliances, measuring and
heat appliances as well as in many other areas.
Depending on their individual temperature limits
these cables are splitted in different resistant
classes which cover temperature ranges from
190C to +1200C.
The different insulant classes into which these
cables are splitted, is effected as per VDE 0530
part 1 in the classes Y, A, E, B, F, H, C.
For detailed information please see technical
information.

E2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description

Page

HELUTHERM 120,flexible, heat-resistant (+105C), meter marking .............................................................................................................


HELUTHERM 145 MULTI,flexible, cross-linked, halogen-free, meter marking ..............................................................................................

SiHF,silicon mulitcore cable, flexible, halogen-free, meter marking ..................................................................................................................

THERMFLEX 180 EWKF,(H05SS-F) halogen-free, silicone multicore cable, meter marking .......................................................................................
H05SS-F / H05SST-F,heat-resistant multicore cable ..........................................................................................................................

HELUFLON -FEP-6Y,multi core, fluorinated polymeric materials,

...........................................................................................

-100C up to +205

MULTITHERM 400,halogen-free ...........................................................................................................................................................

HELUTHERM 145 MULTI-C,flexible, cross-linked, halogen-free, Cu-screened, EMC-preferred type, meter marking ................................................

SiHF/GL-P,silicon mulitcore cable, steel braiding, halogen-free......................................................................................................................


SiHF-C-Si,silicon multicore cable, halogen-free, Cu-screened,

........................................................................
THERMFLEX 180 EWKF-C,silicone multicore cable, Cu-screened, halogen-free, +180C, EMC-preferred type, meter marking .........................................
MULTITHERM 400 -ES,halogen-free, high-grade steel braiding ...................................................................................................................

EMC-preferred type, meter marking

E 4
E 5
E 7
E 9

E 10
E 11
E 13
E 14
E 16
E 17
E 19
E 20

E3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTHERM 120

flexible, heat-resistant (+105C), meter marking

Technical data

Cable structure

Properties

Special PVC cable with increased


heat-resistance
adapted to DINVDE0281 part12
0,5-0,75 mm according IEC60227/56
1,0-2,5 mm according IEC60227/57
Temperature range
flexing -5 C to 105 C
fixed installation -30 C to +105 C
(up to +120 C for short time)
Nominal voltage
0,5-1 mm: U0/U 300/500 V
1,5 mm and above: U0/U 450/750 V
Spark-test 6000 V
Test voltagI 2000 V
Breakdown voltage min. 4000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper conductors to DINVDE0295


cl.5, BS6360 cl.5 and IEC60228 cl.5
Special PVC core insulation, TI3 to
DINVDE0281 part1
Core identification to DINVDE0293-308
Core colours:
up to 5 cores one-coloured
6 and more cores, black with numbering
3 and above, with green-yellow earth core
2 cores without green-yellow earth core
Cores stranded in layers with optimal
lay-length
Special PVC outer jacket, heat-resistant TM3
to DINVDE0281 part1
Outer jacket black (RAL 9005), other colours
on request
with meter marking, change-over in 2011

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
On request
HELUTHERM 120 H03V2V2-F
HELUTHERM 120 H05V2V2-F
HELUTHERM 120 (H)05V2V2-F

Application
Therm cables are ideal for use in machines, appliances or motors which are subject to direct contact with high temperatures (e.g. varnishing
machines and drying towers etc.).
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
24002
24003
24004
24005
24006
24007
24008
24009
24011
24012
24013
24014
24015
24016
24017
24018
24019
24020
24021
24022
24023
24024
24025
24026
24027
24028

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75
1x1
2x1
3G1
4G1
5G1
6G1
7G1
12G1
18G1
25G1

Outer
approx. mm
5,0
5,3
5,8
6,7
8,8
11,1
12,9
15,8
6,2
6,6
7,1
8,0
9,5
11,6
13,9
16,9
6,0
6,5
6,9
7,7
8,4
9,3
10,0
12,5
14,7
17,8

Cop.
weight
kg/km
9,6
14,4
19,2
24,0
33,6
58,0
86,0
101,0
14,4
21,6
29,0
36,0
50,0
86,0
130,0
180,0
9,6
19,2
29,0
38,0
48,0
58,0
67,0
115,0
173,0
240,0

Weight
approx.
kg/km
40,0
50,0
60,0
70,0
90,0
140,0
170,0
250,0
52,0
61,0
75,0
94,0
112,0
180,0
270,0
380,0
50,0
60,0
73,0
88,0
110,0
121,0
130,0
223,0
350,0
485,0

AWG-No.
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17


Part no.
24030
24031
24032
24033
24034
24035
24036
24037
24039
24046
24040
24041
24042
24044
24291
24045
24292

No.cores x
cross-sec.
mm
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
2x4
3G4
4G4
5G4

Outer
approx. mm
7,4
8,1
9,0
10,0
11,9
14,5
17,4
21,3
9,3
10,1
11,0
12,3
14,6
10,6
11,5
12,5
15,1

Cop.
weight
kg/km
29,0
43,0
58,0
72,0
101,0
173,0
259,0
360,0
48,0
72,0
96,0
120,0
168,0
77,0
115,0
154,0
192,0

Weight
approx.
kg/km
77,0
97,0
122,0
143,0
179,0
310,0
460,0
650,0
120,0
150,0
200,0
250,0
310,0
180,0
220,0
300,0
360,0

AWG-No.
16
16
16
16
16
16
16
16
14
14
14
14
14
12
12
12
12

Dimensions and specifications may be changed without prior notice. (RE01)

E4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTHERM 145 MULTI

flexible, cross-linked, halogen-free, meter

marking


Technical data

Cable structure

Properties

Halogen-free control and connecting cable


with increased heat resistance
Temperature range
flexing -35 C to +120 C
fixed installation -55 C to +145 C
in short-circuit +250 C
Nominal voltage
U0/U 300/500 V up to 1,0 mm
U0/U 450/750 V at 1,5 mm
with protected fixed installation
U0/U 600/1000 Vat 1,5 mm
Test voltage 3500 V
Minimum bending radius
for fixed installation 4x cable
in operation to -30 C 12x cable
in operation to +60 C 8x cable
Caloric load values
see Technical Informations
Power ratings table
see Technical Informations
Approval
Germanischer Lloyd

Tinned Cu wires, according to DINVDE0295


class5, BS6360 cl.5 and IEC60228 class 5
Core insulation of polyolefin-copolymer,
cross-linked and halogen-free
Colour coded to DINVDE0293-308 and as
of 6 cores number coded
For two cores: brown, blue
Green-yellow earth core as of 3 cores
Cores stranded in layers with optimal
lay-length
Taping/Mica-Tape
Polyolefin-Copolymer,cross-linked and
halogen-free outer sheath
Colour black
with meter marking, change-over in 2011
Different insulation- and outer sheath in
other colours available on request.


Reduced flame propagation


Good abrasion and notch resistance
Good resistance to oils and weathering
Resistant to UV radiation and ozone
Resistant to soldering temperatures
Thermal class B
Are resistant to melting, even when in
contact with a temperatures of between
300 C and 380 C, because of the
cross-linking for the insulation material
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Tests
Flame test (unit flame test)to VDE
0482-332-3, BS 4066 part 3/ DIN EN
60332-3-22,IEC 60332-3-22 (equivalent DIN
VDE 0472 part 804 test method C)
Flame test (cable) to VDE 0482-332-1-2, DIN
EN 60332-1-2, IEC 60332-1-2 (equivalent
DIN VDE 0472 part 804 test method B)
Corrosiveness of combustion gases
according to VDE0482 part 267/ DINEN
50267-2-2/ IEC60754-2 (equivalent DIN
VDE0472 part813)
Halogen-free according to DINVDE0482
part267/ EN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density to VDE0482 part268-1 and
2, test methodC, IEC61034-1/61034-2,
HD606 and BS7622 part1 and2
(DINVDE0472 part816)


Note

G = with green-yellow earth core


x = without green-yellowearth core
screened analogue type:
HELUTHERM 145 MULTI-C
see page E 14

Application

These halogen-free, cross-linked and temperature resistant wiring and control cables with enhanced fire-behaviour properties are used for
wiring up the lighting fixtures, heaters, electric machines (temperature class B), switching systems and distribution switchboards. A very
long service life is also given on account of their excellent high-temperature stability.
These cables exhibit good resistance to weathering as well as being very stable to temperature, moisture, ozone and UV radiation. These
cables are therefore mainly used for traffic control systems and diverse outdoor applications. The development of smoke is low and no
corrosive gases are liberated during combustion of these halogen-free cables in case of fire. The risk of toxic fumes is considerably less in
the event of fire because the coloric load values is lower. Precious time can thus be won for a disciplined evacuation, and unnecessary loss
of life can be prevented. The extent of the damage to costly control and monitoring systems and the concrete and steel structures of
buildings and plant due to fire is reduced by this. Injuries to persons and damage to materials can be prevented. A lower conductor
cross-section is possible in certain circumstances because of the high thermal load and thus savings in the space and weight required can
be made. These wiring and control cables provide a significant contribution in safety engineering and environmental protection.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
53376
53377
53378

No.cores x
cross-sec.
mm
1x0,25
2x0,25
3G0,25

Outer
approx. mm
2,9
4,6
4,9

Cop.
weight
kg/km
2,4
4,8
7,2

Weight
approx.
kg/km
11,4
28,7
33,7

AWG-No.
24
24
24


Part no.
53379
53380
53381

No.cores x
cross-sec.
mm
4G0,25
5G0,25
6G0,25

Outer
approx. mm
5,5
5,8
6,5

Cop.
weight
kg/km
9,6
12,0
14,4

Weight
approx.
kg/km
41,8
47,0
58,0

AWG-No.
24
24
24

Continuation

E5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTHERM 145 MULTI


marking

Part no.
53382
53383
53384
53385
53386
53387
53388
53389
53391
53392
53393
53394
53395
53396
53397
53398
53399
53400
53401
53402
53403
53404
53405
53406
53407
53408
53409
53410
53411
53412
53413
53414
53415
53416
53417
53418
53419
53420
53421
53422
53423
53424
53425
53426
53427
53428
53429
53430
53431
53432
53433
53434
53435
53436
53437
53438
53439
53440
53441
53442
53443
53444
53445
53446
53447
53448
53449
53450
53451
53452
53453
53454
53455
53456
53457
53458
53459
53460
53461
53462
53463
53464

No.cores x
cross-sec.
mm
7G0,25
8G0,25
10G0,25
12G0,25
14G0,25
16G0,25
19G0,25
21G0,25
1x0,5
2x0,5
3G0,5
4G0,5
5G0,5
6G0,5
7G0,5
8G0,5
10G0,5
12G0,5
14G0,5
16G0,5
19G0,5
21G0,5
24G0,5
25G0,5
27G0,5
30G0,5
33G0,5
37G0,5
1x0,75
2x0,75
3G0,75
4G0,75
5G0,75
6G0,75
7G0,75
8G0,75
10G0,75
12G0,75
14G0,75
16G0,75
19G0,75
21G0,75
24G0,75
25G0,75
27G0,75
30G0,75
33G0,75
37G0,75
1x1
2x1
3G1
4G1
5G1
6G1
7G1
8G1
10G1
12G1
14G1
16G1
19G1
21G1
24G1
25G1
27G1
30G1
33G1
37G1
1x1,5
2x1,5
3G1,5
4G1,5
5G1,5
6G1,5
7G1,5
8G1,5
10G1,5
12G1,5
14G1,5
16G1,5
19G1,5
21G1,5

Outer
approx. mm
6,9
7,3
8,1
8,1
8,6
8,9
10,1
10,5
3,2
5,1
5,5
5,9
6,7
7,1
7,8
8,6
9,4
9,4
10,0
10,7
12,4
13,0
14,0
14,0
14,0
15,0
15,0
17,0
3,5
5,9
6,2
6,9
7,7
8,3
9,1
10,2
11,1
11,1
11,7
12,5
14,0
15,0
16,0
16,0
16,0
17,0
18,0
19,0
3,9
6,3
6,8
7,4
8,3
8,9
9,9
11,0
12,1
12,1
12,7
13,6
15,1
16,0
17,1
17,1
17,1
17,7
18,9
20,3
4,3
7,6
8,1
8,8
9,8
10,9
12,0
14,0
14,6
14,6
15,4
16,2
18,3
19,7

Cop.
weight
kg/km
16,8
19,2
24,0
28,8
33,6
38,4
45,6
50,4
4,8
9,6
14,4
19,2
24,0
28,8
33,6
38,4
48,0
57,6
67,2
76,8
91,2
100,8
115,2
120,0
129,6
144,0
158,4
177,6
7,2
14,4
21,6
28,8
36,0
43,2
50,4
57,6
72,0
86,4
100,8
115,2
136,8
151,2
172,8
180,0
194,4
216,0
237,6
266,4
9,6
19,2
28,8
38,4
48,0
57,6
67,2
76,8
96,0
115,2
134,4
153,6
182,4
201,6
230,4
240,0
259,2
288,0
316,8
355,2
14,4
28,8
43,2
57,6
72,0
86,4
100,8
115,2
144,0
172,8
201,6
230,4
273,6
302,4

Weight
approx.
kg/km
64,0
71,0
84,0
90,0
102,0
114,0
132,0
145,0
15,7
39,6
48,1
51,0
64,0
74,0
88,0
102,0
123,0
135,0
153,0
176,0
213,0
234,0
263,0
269,0
280,0
311,0
343,0
392,0
19,8
40,0
53,0
69,0
86,0
101,0
117,0
140,0
167,0
183,0
212,0
239,0
290,0
323,0
364,0
371,0
387,0
429,0
468,0
550,0
25,2
50,0
66,0
86,0
106,0
127,0
155,0
187,0
214,0
230,0
266,0
301,0
377,0
419,0
464,0
472,0
488,0
536,0
605,0
690,0
32,3
69,0
93,0
120,0
152,0
187,0
222,0
263,0
308,0
330,0
383,0
438,0
554,0
614,0

AWG-No.
24
24
24
24
24
24
24
24
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16

flexible, cross-linked, halogen-free, meter



Part no.
53465
53466
53467
53468
53469
53470
53471
53472
53473
53474
53475
53476
53477
53478
53479
53480
53481
53482
53483
53484
53485
53486
53487
53488
53489
53490
53491
53492
53493
53494
53495
53496
53497
53498
53499
53500
53501
53502
53503
53504
53505
53506
53507
53508
53509
53510
53511
53512
53513
53514
53515
53516
53517
53518
53519
53520
53521
53522
53523
53524
53525
53526
53527
53528
53529
53530
53531
53532
53533
53534
53535
53536
53537
53538
53539
53540
53541
53542
53543
53544
53545
53546
53547
53548
53549

No.cores x
cross-sec.
mm
24G1,5
25G1,5
27G1,5
30G1,5
33G1,5
37G1,5
1x2,5
2x2,5
3G2,5
4G2,5
5G2,5
6G2,5
7G2,5
8G2,5
10G2,5
12G2,5
14G2,5
16G2,5
19G2,5
21G2,5
24G2,5
25G2,5
27G2,5
30G2,5
33G2,5
37G2,5
1x4
2x4
3G4
4G4
5G4
6G4
7G4
8G4
10G4
12G4
14G4
1x6
2x6
3G6
4G6
5G6
6G6
7G6
1x10
2x10
3G10
4G10
5G10
6G10
7G10
1x16
2x16
3G16
4G16
5G16
6G16
7G16
1x25
2x25
3G25
4G25
5G25
6G25
7G25
1x35
2x35
3G35
4G35
5G35
1x50
2x50
3G50
4G50
5G50
1x70
2x70
3G70
4G70
5G70
1x95
2x95
3G95
4G95
5G95

Outer
approx. mm
21,1
21,1
21,1
21,8
22,6
24,8
5,0
9,0
9,8
10,8
12,0
13,2
14,6
15,7
17,7
18,7
19,0
20,1
20,7
23,7
25,8
25,8
25,8
26,7
28,0
30,6
5,6
10,2
10,9
12,2
13,5
14,9
16,4
17,6
20,1
20,1
21,5
6,1
11,6
12,4
13,8
15,4
16,7
18,3
7,7
14,7
15,7
17,5
19,6
21,7
23,7
9,1
17,7
19,3
21,5
23,9
26,2
28,9
10,9
21,3
22,7
25,4
28,1
31,1
34,5
12,1
23,7
25,5
28,4
31,3
14,9
29,3
31,5
35,3
39,1
17,1
33,7
36,4
40,3
44,5
19,2
37,5
40,0
45,3
50,7

Cop.
weight
kg/km
345,6
360,0
388,8
432,0
475,2
532,8
24,0
48,0
72,0
96,0
120,0
144,0
168,0
192,0
240,0
288,0
336,0
384,0
456,0
504,0
576,0
600,0
648,0
720,0
792,0
888,0
38,4
76,8
115,2
153,6
192,0
230,4
268,8
307,2
384,0
460,8
537,6
57,6
115,2
172,8
230,4
288,0
345,6
403,2
96,0
192,0
288,0
384,0
480,0
576,0
672,0
153,6
307,2
460,8
614,4
768,0
921,6
1075,2
240,0
480,0
720,0
960,0
1200,0
1440,0
1680,0
336,0
672,0
1008,0
1344,0
1680,0
480,0
960,0
1440,0
1920,0
2400,0
672,0
1344,0
2016,0
2688,0
3360,0
912,0
1824,0
2736,0
3648,0
4560,0

Weight
approx.
kg/km
791,0
701,0
723,0
796,0
880,0
1026,0
46,9
99,0
140,0
183,0
231,0
280,0
336,0
397,0
460,0
500,0
593,0
675,0
835,0
939,0
1047,0
1067,0
1107,0
1219,0
1349,0
1565,0
96,0
159,0
197,0
260,0
329,0
398,0
478,0
553,0
663,0
725,0
797,0
88,0
216,0
285,0
375,0
465,0
544,0
664,0
144,0
351,0
475,0
630,0
782,0
914,0
1092,0
205,0
495,0
691,0
905,0
1129,0
1327,0
1590,0
336,0
833,0
1139,0
1489,0
1863,0
2275,0
2633,0
454,0
1104,0
1513,0
1992,0
2488,0
638,0
1573,0
2154,0
2819,0
3505,0
875,0
2157,0
2946,0
3888,0
4864,0
1149,0
2763,0
3835,0
5052,0
6307,0

AWG-No.
16
16
16
16
16
16
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
12
12
12
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10
8
8
8
8
8
8
8
6
6
6
6
6
6
6
4
4
4
4
4
4
4
2
2
2
2
2
1
1
1
1
1
2/0
2/0
2/0
2/0
2/0
3/0
3/0
3/0
3/0
3/0

Dimensions and specifications may be changed without prior notice. (RE01)

E6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SiHF

silicon mulitcore cable, flexible, halogen-free, meter marking

Technical data

Cable structure

Special silicone multicore cable with higher


heat-resistance range adapted to
DINVDE0250 part1 and part816
Temperature range
-60 C to +180 C
(up to +220 C for short time)
Temperature limit at the conductor
in operation +180 C
Nominal voltage U0/U 300/500 V
Test voltage 2000 V
Breakdown voltage min. 5000 V
Insulation resistance
min. 200 MOhm x km
Power rating
at ambient temperature up to +145 C
to DINVDE0100 for higher temperatures
valid:
150 C - load value 100%
155 C - load value 91%
160 C - load value 82%
165 C - load value 71%
170 C - load value 58%
175 C - load value 41%
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 20x106 cJ/kg (up to 20 Mrad)

Tinned fine wire copper conductors to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Silicone core insulation
Core colours according DINVDE0293-308
Core colour
- up to 5 cores one-coloured
- up 6 and more cores, black with white
numbering
- 3 and above, with green-yellow earth core
- 2 cores without green-yellow earth core
Cores stranded in layers with optimal
lay-length 
Outer jacket of silicone
Jacket colour preferably redbrown
with meter marking, change-over in 2011

Properties

Advantages
Hardly changes of dielectric strength and
the insulation resistance also at high
temperatures, high ignition or flash point,
in case of fire, forms an insulating layer of
SiO2
Resistant to
High molecular oils, fats from vegetables
and animals, alcohols, plasticizers and
clophenes, diluted acids, lyes and salt
dissolution, oxidation substances, tropical
influences and weather, lake water, oxygen
and UV
Halogen-free
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Behaviour in fire
no flame propagation
test according to DINVDE0482
part265-2-1/ EN50265-2-1/ IEC60332-1
(equivalent DINVDE0472 part804 test
methodB)
For laying as a fixed installation only in open
or ventilated pipe systems as well as in
ducts. Otherwise the mechanical properties
of the silicon are reduced by the enclosed
air at temperatures exceeding 90 C.


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OB).
screened analogue type:
SIHF-C-SI see page E 17


Application
Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. They are heat-resistant for permanent
temperature up to +180 C, for short time operation up to +220 C. The good performance of the environmental resistant properties means
that silicone cables can be used at temperatures down to -60 C. Silicone cables are halogen-free cables and are especially suited for installation
in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic,
glass and cement factories.
Due to elastical characteristic of core insulations, these are used as flexible connection cable.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
22989
22990
22940
22991
22941
22992
22942
22993
22994
22995
22996
22997
22998
22999
23000
23001

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4G0,5
4x0,5
5G0,5
5x0,5
6G0,5
7G0,5
8G0,5
10G0,5
12G0,5
16G0,5
18G0,5
25G0,5
2x0,75

Outer
approx. mm
5,6
5,9
5,9
6,4
6,4
7,3
7,3
8,3
8,1
8,9
10,0
10,6
12,1
12,7
15,2
6,4

Cop.
weight
kg/km
9,6
14,5
14,5
19,3
19,3
24,0
24,0
28,9
33,7
38,4
48,1
57,6
76,7
86,5
120,0
14,4

Weight
approx.
kg/km
42,0
44,0
44,0
58,0
58,0
62,0
62,0
79,0
85,0
99,0
124,0
141,0
186,0
211,0
271,0
53,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
18


Part no.
23002
23104
23003
23105
23004
22943
23005
23006
23127
23128
23129
23130
23131
23132
23007
23008

No.cores x
cross-sec.
mm
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
6G0,75
7G0,75
8G0,75
10G0,75
12G0,75
16G0,75
18G0,75
25G0,75
2x1
3G1

Outer
approx. mm
6,8
6,8
7,6
7,6
8,5
8,5
9,2
9,2
9,9
11,1
12,2
13,7
14,6
17,2
6,6
7,0

Cop.
weight
kg/km
21,6
21,6
29,0
29,0
36,0
36,0
43,0
50,0
57,7
72,1
86,5
115,2
129,7
180,0
19,0
29,0

Weight
approx.
kg/km
63,0
63,0
83,0
83,0
101,0
101,0
115,0
124,0
138,0
156,0
185,0
218,0
260,0
370,0
59,0
77,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17

Continuation

E7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SiHF

silicon mulitcore cable, flexible, halogen-free, meter marking


Part no.
22944
23009
22945
23010
22946
23011
23012
23133
23134
23135
23136
23137
23138
23013
23014
22947
23015
22948
23016
22949
23017
23018
23019
23020
23021
23022
23023
23024
23025
23026
23027
23028
23029
23030
23139
23032
23140
23141

No.cores x
cross-sec.
mm
3x1
4G1
4x1
5G1
5x1
6G1
7G1
8G1
10G1
12G1
16G1
18G1
25G1
2x1,5
3G1,5
3x1,5
4G1,5
4x1,5
5G1,5
5x1,5
6G1,5
7G1,5
8G1,5
10G1,5
12G1,5
14G1,5
16G1,5
18G1,5
20G1,5
24G1,5
2x2,5
3G2,5
4G2,5
5G2,5
6G2,5
7G2,5
8G2,5
10G2,5

Outer
approx. mm
7,0
7,8
7,8
8,8
8,8
9,5
9,5
10,3
11,5
12,5
14,2
15,1
18,0
7,6
8,0
8,0
8,7
8,7
9,6
9,6
10,4
10,4
11,2
13,0
13,9
14,7
16,2
17,0
17,5
20,4
8,8
9,7
10,6
11,6
12,6
12,6
13,6
15,5

Cop.
weight
kg/km
29,0
38,0
38,0
48,0
48,0
58,0
67,0
76,7
96,1
115,2
153,5
172,9
240,0
29,0
43,0
43,0
58,0
58,0
72,0
72,0
86,0
101,0
114,0
116,0
173,0
202,0
231,0
260,0
288,0
346,0
48,0
72,0
96,0
120,0
144,0
168,0
192,2
240,1

Weight
approx.
kg/km
77,0
94,0
94,0
115,0
115,0
134,0
144,0
175,0
216,0
231,0
302,0
340,0
431,0
81,0
98,0
98,0
122,0
122,0
147,0
147,0
173,0
187,0
213,0
263,0
314,0
379,0
445,0
506,0
566,0
722,0
134,0
152,0
188,0
228,0
304,0
320,0
373,0
450,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14


Part no.
23033
23142
23143
23144
23034
23035
23036
23037
23039
23040
23041
23042
23043
23045
23046
23047
23048
23049
23145
23050
23051
23052
23053
23146
23054
23055
23056
23057
23058
23059

No.cores x
cross-sec.
mm
12G2,5
16G2,5
18G2,5
25G2,5
2x4
3G4
4G4
5G4
7G4
2x6
3G6
4G6
5G6
7G6
2x10
3G10
4G10
5G10
7G10
2x16
3G16
4G16
5G16
7G16
2x25
3G25
4G25
2x35
3G35
4G35

Outer
approx. mm
17,1
19,6
20,6
24,4
10,8
11,4
12,5
13,9
15,6
12,4
13,2
14,8
16,5
18,0
16,2
17,2
19,4
21,4
23,4
18,0
19,3
21,4
24,0
26,4
22,0
23,4
26,3
24,6
26,3
29,1

Cop.
weight
kg/km
288,0
384,0
432,2
600,0
77,0
115,0
154,0
192,0
269,0
115,0
173,0
230,0
288,0
403,0
192,0
288,0
384,0
480,0
672,2
308,0
462,0
616,0
770,0
1075,3
480,0
720,0
960,0
672,0
1008,0
1344,0

Weight
approx.
kg/km
502,0
659,0
761,0
1007,0
180,0
224,0
295,0
359,0
479,0
210,0
270,0
341,0
432,0
552,0
400,0
507,0
644,0
788,0
1151,0
591,0
749,0
950,0
1204,0
1682,0
700,0
1100,0
1500,0
1100,0
1500,0
2100,0

AWG-No.
14
14
14
14
12
12
12
12
12
10
10
10
10
10
8
8
8
8
8
6
6
6
6
6
4
4
4
2
2
2

Dimensions and specifications may be changed without prior notice. (RE01)

E8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

THERMFLEX 180 EWKF

(H05SS-F) halogen-free, silicone multicore

cable, meter marking




Technical data

Cable structure

Heat-resistant silicone-insulated flexible


cable in adapted to DINVDE0250 part816
Temperature range
flexing -25 C to +180 C
fixed installation -60 C to +180 C
(short time operation +220 C)
Nominal voltage U0/U 300/500 V
Test voltage 2000 V
Insulation resistance
min. 200 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 20x106 cJ/kg (up to 20 Mrad)
Insulation integrity continuance of
insulation effects under fire condition
according to IEC60331 and DINVDE0472
part814
Freedom from halogen (corrosiveness
of combustion gases) according to
VDE0482 part267/ DINEN50267-2-2/
IEC60754-2 (equivalent DINVDE0472
part813)
Behaviour in fire no flame propagation,
test according to DINVDE0482
part265-2-1/ EN50265-2-1/ IEC60332-1
(equivalent DINVDE0472 part804 test
methodB)

Tinned copper conductor, stranded to


DINVDE0295, cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special silicone core insulation,EI2to
DINVDE0207 part20
Core identification to DINVDE0293-308
up to 5cores one-coloured,
6 and more cores black with white
numbering
Green-yellow earth core (3 cores and above)
Cores stranded in layers with optimal
lay-length
Silicone outer jacket, 2GM1 to DINVDE0207
part21
Jacket colour black (RAL9005)
with meter marking, change-over in 2011
Different dimensions also approved by
Germanischer Lloyd on request.

Properties

Smoke density - low


Due to the special abrasive and notch
resistance outer jacket, these cables are
suitable for heavy loading of mechanical
stresses than the usual standard silicone
cables
Hardly changes of dielectric strength and
the insulation resistance also at high
temperatures
High ignition or flash point
In case of fire, forms an insulating layer of
Resistant to
High molecular oils, fats from vegetables
and animals, alcohols, plasticizers and
clophenes, diluted acids, lyes and salt
dissolution, oxidation substances, tropical
influences and weather, lake water, oxygen,
ozone


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
EWKF = Improved values to E=tearing
resistance, W=breaking strength
propagation, K=notch strength,
F=flexibility
screened analogue type:
THERMFLEX 180 EWKF-C
see page E 19

Application
These cables are ideal for use everywhere, where increased mechanical stresses for the installation and operation are required.
Silicone-rubber-insulated cables are used for all applications where the cable insulation is subjected to high temperature fluctuations. Suitable
for installation at high temperature influence in dry, damp and in the open air. As flexible connecting cable for low mechanical stress i.e.
sauna, solar installations, foundries and steel plants. This cable can be used for fixed installation only in open and ventilated cable tubes and
cable ducts.
FRNC = Flame Retardant Non Corrosive
All silicon cables are available also in FRNC versions. The jacket designed with special-compound conform flame test method C to DIN VDE
0472 part 804 and IEC 60332-3 as well as HD 405.3. This special compound is self-extinguishing. Because of that these cables can be installed
as security cable with functionality as for example in communal buildings, power stations, hotels, airports etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
74992
74993
74994
74995
74996
74997
74998
74999
75000
75001
75002
75003
75004
75005
75006
75007

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
2x1
3G1
4G1
5G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
16G1,5
20G1,5

Outer
approx. mm
6,4
7,0
7,6
8,5
6,8
7,2
7,8
8,8
8,8
8,9
9,9
10,8
12,0
16,1
18,2
19,4

Cop.
weight
kg/km
15,0
22,0
29,0
36,0
20,0
29,0
39,0
48,0
29,0
43,0
58,0
72,0
101,0
173,0
231,0
288,0

Weight
approx.
kg/km
53,0
64,0
84,0
101,0
60,0
78,0
95,0
116,0
82,0
98,0
122,0
148,0
187,0
315,0
446,0
566,0

AWG-No.
18
18
18
18
17
17
17
17
16
16
16
16
16
16
16
16


Part no.
75008
75009
75010
75011
75012
75013
75014
75015
75016
75017
75018
75019

No.cores x
cross-sec.
mm
2G2,5
3G2,5
4G2,5
5G2,5
2x4
3G4
4G4
5G4
2x6
3G6
4G6
5G6

Outer
approx. mm
9,8
10,4
11,5
12,9
11,6
12,3
13,6
15,2
13,2
14,0
15,5
17,2

Cop.
weight
kg/km
48,0
72,0
96,0
120,0
77,0
115,0
154,0
192,0
115,0
173,0
230,0
288,0

Weight
approx.
kg/km
135,0
152,0
189,0
229,0
180,0
230,0
300,0
380,0
321,0
330,0
430,0
550,0

AWG-No.
14
14
14
14
12
12
12
12
10
10
10
10

Dimensions and specifications may be changed without prior notice. (RE01)

E9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H05SS-F / H05SST-F

heat-resistant multicore cable

Technical data

Cable structure

Heat-resistant multicore cable to


DINVDE0282 part15, HD22.15S1
Temperature range
fixed installation -60 C to +180 C
(250 C for short time)
Temperature limit
at conductor in operation +180 C
Nominal voltage U0/U 300/500 V
Test voltage 2000 V
Specific volume resistivity
min. 200 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 20x106 cJ/kg (up to 20 Mrad)

Tinned or bare1) copper conductor,


stranded to DINVDE0295 cl.5, BS6360
cl.5, HD383 cl.5 and IEC60228
SiR core insulation, crosslinked (rubber
compound) E I2 to DINVDE0207 part20
Core identification to DINVDE0293-308
Green-yellow earth core, 3 cores and above
Cores stranded in layers with optimal
lay-length
Outer jacket of crosslinked EM9 (rubber
compound) to HD22.3S3:1994 / A1:1999
Jacket colour black (RAL9005)
Also available in other sheath colours
Cable structure H05SST-F
As per H05SS-F
Polyester braiding

Properties

Behavior in fire:
Test of vertical flame-propagation to
DINVDE0482 part265-2-1 and
DINEN50265-2-1, not valid for the cables
with polyesterbraiding (TypeH05SST-F)
Advantages Hardly changes of dielectric
strength and the insulation resistance also
at high temperatures
For laying as a fixed installation only in open
or ventilated pipe systems as well as in
ducts. Otherwise the mechanical properties
of the silicon are reduced by the enclosed
air at temperatures exceeding 90 C. These
cables may be damaged by pulling over
sharp-edges or by abrasion during the
installation and application. To avoid this,
it should be treated with great care during
the installation and application of the cable.


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.


Application
Multicore cables insulated and sheathed with heat resistant silicone rubber without strain relieving elements are used in high temperatures
or with contact to hot-surfaces. These cables are installed for fixed installation, mechanical protected, for internal wiring of lighting fixtures
in industrial application. It is recommended for the application of the apparatus which are moving during the operation with less mechanical
stress.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


H05SS-F
Part no.
22290
22291
22292
22293
22294
22295
22296
22297
22298
22299
22300
22301
22302
22303
22304
22305
22306
22307
22308
22309

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
2x1
3G1
4G1
5G1
2x1,5
3G1,5
4G1,5
5G1,5
2x2,5
3G2,5
4G2,5
5G2,5
3G4
4G4
3G6
4G6

Outer
min. - max.
mm
5,7 - 7,4
6,2 - 8,1
6,8 - 8,8
7,6 - 9,9
6,1 - 8,0
6,5 - 8,5
7,1 - 9,3
8,0 - 10,3
7,6 - 9,8
8,0 - 10,4
9,0 - 11,6
9,8 - 12,7
9,0 - 11,6
9,6 - 12,4
10,7 - 13,8
11,9 - 15,3
11,3 - 14,5
12,7 - 16,2
12,8 - 16,3
14,2 - 18,1

Cop.
weight
kg/km
14,4
21,6
28,8
36,0
19,2
29,0
38,4
48,0
29,0
43,0
58,0
72,0
48,0
72,0
96,0
120,0
115,0
154,0
173,0
230,0

Weight
approx.
kg/km
59,0
71,0
93,0
113,0
67,0
86,0
105,0
129,0
91,0
110,0
137,0
165,0
150,0
170,0
211,0
255,0
251,0
330,0
379,0
494,0

AWG-No.
18
18
18
18
17
17
17
17
16
16
16
16
14
14
14
14
12
12
10
10

H05SS-F
Part no.
22343
22344
22345
22346
22347
22348
22349
22350
22351
22352
22353
22354
22355
22356
22357
22358
22359
22360
22361
22362

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
2x1
3G1
4G1
5G1
2x1,5
3G1,5
4G1,5
5G1,5
2x2,5
3G2,5
4G2,5
5G2,5
3G4
4G4
3G6
4G6

Outer
min. - max.
mm
6,7 - 8,4
7,2 - 9,1
7,8 - 9,8
8,6 - 10,9
7,1 - 9,0
7,5 - 9,5
8,1 - 10,3
9,0 - 11,3
8,6 - 10,8
9,0 - 11,4
10,0 - 12,6
10,8 - 13,7
10,0 - 12,6
10,6 - 13,4
11,7 - 14,8
12,9 - 16,3
12,3 - 15,5
13,7 - 17,2
13,8 - 17,3
15,2 - 19,1

Cop.
weight
kg/km
14,4
21,6
28,8
36,0
19,2
29,0
38,4
48,0
29,0
43,0
58,0
72,0
48,0
72,0
96,0
120,0
115,0
154,0
173,0
230,0

Weight
approx.
kg/km
63,0
75,0
99,0
120,0
71,0
91,0
111,0
137,0
97,0
117,0
145,0
175,0
159,0
180,0
224,0
270,0
266,0
350,0
402,0
524,0

AWG-No.
18
18
18
18
17
17
17
17
16
16
16
16
14
14
14
14
12
12
10
10

Dimensions and specifications may be changed without prior notice. (RE01)

E 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUFLON-FEP-6Y

multi core, fluorinated polymeric materials,

-100C up to +205


Technical data

Cable structure

Properties

Fluorinated polymeric insulation FEP


(Fluorethylenepropylene)
Temperature range
-100 C to +205 C
(up to +230 C for short time)
Nominal voltage 600 V
Test voltage 2500 V
Insulation resistance
min. 2 GOhm x km
Minimum bending radius
flexing 15x cable
fixed installation 4x cable
Radiation resistance
up to 1x106 cJ/kg (up to 1 Mrad)
Conductor temperature range
plain copper +130 C
tinned copper +180 C
silver pl. copper +200 C

Stranded copper wire, bare, tinned, silver


Make-up fine wire stranded to
DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation FEP-HELUFLON
Green-yellow earth core
0,25 mm colour code to DIN VDE 0293-308
0,5 mm and above black cores with white
imprints
Outer jacket FEP-HELUFLON
Colour black (RAL 9005)

Higher insulation resistance


Low dielectric loss
Not flammable
Resistant to micro-cultures
Do not permit any fungus-formation
Absolute ozone resistant
Absolute weather resistant
Water absorption <0,01%
Minimal water vapour permeability (approx.
0,18 mgr/cm in 24 hours)
Self-extinguishing and flame retardant
according to DINVDE0482 part265-2-1/
EN50265-2-1/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.


Application
This cables are predominantly used for installing in control cabinets subjected to high thermal effects as well as in brickworks, heaters,
kitchen fitments and measuring appliances as well as in the chemical industry. These cables are non-flammable and resistant to acids, alkalis,
solvents, oil and petrol.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


copper wire, tinned


Part no.
24547
24548
24549
24550
24551
24552
24553
24554
24555
24556
24557
24558
24559
24560
24561
24562
24563
24564
24565

No.cores x
cross-sec.
mm
2x0,25
3G0,25
4G0,25
5G0,25
7G0,25
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
2x1
3G1
4G1
5G1

Outer
approx. mm
2,7
2,9
3,2
3,5
3,9
3,3
3,5
3,9
4,3
4,8
3,6
3,9
4,3
4,7
4,8
4,1
4,4
4,9
5,5

Cop.
weight
kg/km
5,0
7,5
10,0
12,5
17,5
9,8
14,7
19,6
24,5
34,3
14,4
21,6
29,0
36,0
50,0
19,0
29,0
38,0
48,0

Weight
approx.
kg/km
17,0
22,0
27,0
34,0
46,0
21,0
32,0
44,0
55,0
70,0
31,0
46,0
58,0
69,0
92,0
41,0
55,0
71,0
88,0

AWG-No.
24
24
24
24
24
20
20
20
20
20
18
18
18
18
18
17
17
17
17

copper wire, tinned


Part no.
24566
24273
24274
24275
24501
24502
24503
24504
24505
24276
24277
24278
24279
24280
24281
24282
24283
24284
24285

No.cores x
cross-sec.
mm
7G1
12G1
18G1
25G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
3G2,5
4G2,5
5G2,5
7G2,5
3G4
4G4
5G4

Outer
approx. mm
6,0
8,0
9,5
11,2
4,9
5,3
5,8
6,5
7,2
10,2
12,3
14,0
6,4
7,0
7,9
8,7
7,5
8,3
9,2

Cop.
weight
kg/km
67,0
115,2
173,0
240,0
29,0
43,0
58,0
72,0
101,0
173,0
260,0
360,0
72,0
96,0
120,0
168,0
115,0
154,0
192,0

Weight
approx.
kg/km
113,0
220,0
321,0
458,0
45,0
70,0
98,0
117,0
184,0
326,0
504,0
682,0
121,0
182,0
240,0
316,0
212,0
304,0
386,0

AWG-No.
17
17
17
17
16
16
16
16
16
16
16
16
14
14
14
14
12
12
12

Continuation

E 11
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUFLON-FEP-6Y

multi core, fluorinated polymeric materials,

-100C up to +205
copper wire, bare
Part no.
25914
25915
25916
25917
25918
25919
25920
25921
25922
25923
25924
25925
25926
25927
25928
25929
25930
25931
25932
25933
25934
25935
25936
25937
25938
25939
25940
25941
25942
25943
25944
25945
25946
25947
25948
25949
25950
25951

No.cores x
cross-sec.
mm
2x0,25
3G0,25
4G0,25
5G0,25
7G0,25
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
2x1
3G1
4G1
5G1
7G1
12G1
18G1
25G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
3G2,5
4G2,5
5G2,5
7G2,5
3G4
4G4
5G4

Outer
approx. mm
2,7
2,9
3,2
3,5
3,9
3,3
3,5
3,9
4,3
4,8
3,6
3,9
4,3
4,7
5,4
4,1
4,4
4,9
5,5
6,0
8,0
9,5
11,2
4,9
5,3
5,8
6,5
7,2
10,2
12,3
14,0
6,4
7,0
7,9
8,7
7,5
8,3
9,2

Cop.
weight
kg/km
5,0
7,5
10,0
12,5
17,5
9,8
14,7
19,6
24,5
34,3
14,4
21,6
29,0
36,0
50,0
19,0
29,0
38,0
48,0
67,0
115,2
173,0
240,0
29,0
43,0
58,0
72,0
101,0
173,0
260,0
360,0
72,0
96,0
120,0
168,0
115,0
154,0
192,0

Weight
approx.
kg/km
17,0
22,0
27,0
34,0
46,0
21,0
32,0
44,0
55,0
70,0
31,0
46,0
58,0
69,0
92,0
41,0
55,0
71,0
88,0
113,0
220,0
321,0
458,0
45,0
70,0
98,0
117,0
184,0
326,0
504,0
682,0
121,0
182,0
240,0
316,0
212,0
304,0
386,0

AWG-No.
24
24
24
24
24
20
20
20
20
20
18
18
18
18
18
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
14
14
14
14
12
12
12

copper wire, silvered


Part no.
25952
25953
25954
25955
25956
25957
25958
25959
25960
25961
25962
25963
25964
25965
25966
25967
25968
25969
25970
25971
25972
25973
25974
25975
25976
25977
25978
25979
25980
25981
25982
25983
25984
25985
25986
25987
25989
25990

No.cores x
cross-sec.
mm
2x0,25
3G0,25
4G0,25
5G0,25
7G0,25
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
2x1
3G1
4G1
5G1
7G1
12G1
18G1
25G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
3G2,5
4G2,5
5G2,5
7G2,5
3G4
4G4
5G4

Outer
approx. mm
2,7
2,9
3,2
3,5
3,9
3,3
3,5
3,9
4,3
4,8
3,6
3,9
4,3
4,7
5,4
4,1
4,4
4,9
5,5
6,0
8,0
9,5
11,2
4,9
5,3
5,8
6,5
7,2
10,2
12,3
14,0
6,4
7,0
7,9
8,7
7,5
8,3
9,2

Cop.
weight
kg/km
5,0
7,5
10,0
12,5
17,5
9,8
14,7
19,6
24,5
34,3
14,4
21,6
29,0
36,0
50,0
19,0
29,0
38,0
48,0
67,0
115,2
173,0
240,0
29,0
43,0
58,0
72,0
101,0
173,0
260,0
360,0
72,0
96,0
120,0
168,0
115,0
154,0
192,0

Weight
approx.
kg/km
17,0
22,0
27,0
34,0
46,0
21,0
32,0
44,0
55,0
70,0
31,0
46,0
58,0
69,0
92,0
41,0
55,0
71,0
88,0
113,0
220,0
321,0
458,0
45,0
70,0
98,0
117,0
184,0
326,0
504,0
682,0
121,0
182,0
240,0
316,0
212,0
304,0
386,0

AWG-No.
24
24
24
24
24
20
20
20
20
20
18
18
18
18
18
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
14
14
14
14
12
12
12

Dimensions and specifications may be changed without prior notice. (RE01)

E 12
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTITHERM 400

halogen-free

Technical data

Cable structure

Special Cu-nickel silicone-insulated cable


with enhanced heat resistance
Temperature range
-60 C to +400 C
(up to +500 C for short time)
Nominal voltage 500 V
Test voltage 2500 V
Minimum bending radius
approx. 5x cable

Cu wires, finely stranded, nickel plated


(ASTM B 355)
Core insulation of braided glass-fibre
impregnated with silicone
Second core insulation of glass-fibre
braiding impregnated with silicone
Overall lay up of cores
Core identification according to colour
coding listed below
Common outer sheath of glass-fibre
braiding impregnated with silicone
Sheath colour grey

Properties

Asbestos and cadmium-free


Colour code
No. of cores with protective earth
conductor
3 = gn-ye/bl/bn
4 = gn-ye/bk/bl/bn
5 = gn-ye/bk/bl/bn/wh
6 = gn-ye/bk/bl/bn/wh/rd
7 = gn-ye/bk/bl/bn/wh/rd/gy
No. of cores without protective earth
conductor
2 = bl/bn
3 = bk/bl/bn
4 = bk/bl/bn/wh
5 = bk/bl/bn/wh/rd
6 = bk/bl/bn/wh/rd/gy
7 = bk/bl/bn/wh/rd/gy/gn


Note

Enquire for further configurations and core


cross sections for your requirements.
We supply customised cables for
temperature ranges up to approx. 1600 C.
Please enquire for minimum ordering
quantities and delivery times.
screened analogue type:
MULTITHERM 400 -ES
see page E 20

Application

MULTITHERM 400 cables are used for applications where extremely high connecting and ambient temperatures can arise, e.g. in iron and
steel works, rolling mills, foundries, glass and ceramic factories, in furnace and power plant construction, during thermoplastic moulding
processes etc. The special construction of the cable is designed for a recommended maximum temperature in damp environments
of 220 C and for dry environments above this temperature.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
51741
51742
51743
51744
51745
51746
51747
51748
51749
51750
51751
51752
51753
51754
51755
51756
51757
51758
51759
51760
51761
51762
51763
51764
51765
51766
51767
50060

No.cores x
cross-sec.
mm
2x0,5
3x0,5
4x0,5
5x0,5
6x0,5
7x0,5
2x0,75
3x0,75
4x0,75
5x0,75
6x0,75
7x0,75
2x1
3x1
4x1
5x1
6x1
7x1
2x1,5
3x1,5
4x1,5
5x1,5
6x1,5
7x1,5
2x2,5
3x2,5
4x2,5
5x2,5

Outer
approx. mm
6,2
6,4
7,5
8,0
8,6
8,7
6,7
7,0
8,0
8,8
9,5
9,7
6,9
7,8
8,3
9,1
9,8
10,0
8,0
8,3
9,1
10,0
10,7
11,0
9,2
9,7
10,6
11,8

Cop.
weight
kg/km
10,0
15,0
19,0
25,0
30,0
34,0
14,4
21,6
29,0
36,0
43,0
50,0
19,0
29,0
38,0
48,0
58,0
67,0
29,0
43,0
58,0
72,0
88,0
101,0
48,0
72,0
96,0
120,0

Weight
approx.
kg/km
47,0
50,0
70,0
81,0
97,0
105,0
55,0
66,0
86,0
103,0
119,0
130,0
63,0
82,0
98,0
119,0
138,0
150,0
87,0
103,0
128,0
150,0
175,0
190,0
135,0
153,0
190,0
230,0

AWG-No.
20
20
20
20
20
20
18
18
18
18
18
18
17
17
17
17
17
17
16
16
16
16
16
16
14
14
14
14


Part no.
50061
50062
50063
50064
50065
50066
50067
50068
50069
50070
50071
50072

No.cores x
cross-sec.
mm
6x2,5
7x2,5
2x4
3x4
4x4
5x4
7x4
3x6
4x6
5x6
4x10
4x16

Outer
approx. mm
12,8
13,0
11,0
11,4
13,0
14,5
16,5
14,2
16,2
17,7
20,0
24,5

Cop.
weight
kg/km
144,0
168,0
77,0
115,0
154,0
192,0
270,0
173,0
230,0
288,0
384,0
615,0

Weight
approx.
kg/km
270,0
295,0
191,0
224,0
285,0
360,0
485,0
340,0
442,0
535,0
710,0
990,0

AWG-No.
14
14
12
12
12
12
12
10
10
10
8
6

Dimensions and specifications may be changed without prior notice. (RE01)

E 13
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTHERM 145 MULTI-C

flexible, cross-linked, halogen-free,

Cu-screened, EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Halogen-free control and connecting cable


with increased heat resistance
Temperature range
flexing -35 C to +120 C
fixed installation -55 C to +145 C
in short-circuit +250 C
Nominal voltage
U0/U 300/500 V up to 1,0 mm
U0/U 450/750 V at 1,5 mm
with protected fixed installation
U0/U 600/1000 Vat 1,5 mm
Test voltage 3500 V
Minimum bending radius
for fixed installation 4x cable
in operation to -30 C 12x cable
in operation to +60 C 8x cable
Coupling resistance
max. 250 Ohm/km
Caloric load values
see Technical Informations
Power ratings table
see Technical Informations
Approval
Germanischer Lloyd

Tinned copper conductor, fine wire


strandedaccording to DINVDE0295 cl.5,
BS6360 cl.5 and IEC60228 cl.5
Core insulation of polyolefin-copolymer,
cross-linked and halogen-free
Black cores with continuous white
numbering
Cores stranded in layers with optimal
lay-lenght
Braided screen of tinned Cu wires,
coverage approx. 85%
Polyolefin-Copolymer, cross-linked and
halogen-free outer sheath
Colour black
with meter marking, change-over in 2011
Different insulation- and outer sheath in
other colours available on request


Note
unscreened analogue type:
HELUTHERM 145 MULTIsee page E 5

Lower propagation of fire


Low development of smoke and fumes
Good abrasion and notch resistance
Good resistance to oils and weathering
Resistant to UV radiation and ozone
Resistant to soldering temperatures
Thermal class B
These control cables are resistant to
melting, even when in contact with a
soldering iron at temperatures of between
300 C and 380 C, because of the
cross-linking for the insulation material
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Tests
*PEQIXIWX (unit flame test)to VDE
0482-332-3, BS 4066 part 3/ DIN EN
60332-3-22,IEC 60332-3-22 (equivalent DIN
VDE 0472 part 804 test method C)
*PEQIXIWX (cable) to VDE 0482-332-1-2, DIN
EN 60332-1-2, IEC 60332-1-2 (equivalent
DIN VDE 0472 part 804 test method B)

'SVVSWMZIRIWWSJGSQFYWXMSRKEWIW
according to VDE 0482 part 267/ DINEN
50267-2-2/ IEC 60754-2 (equivalent DIN VDE
0472 part 813)

,EPSKIRJVII according to VDE0482
part267/ DINEN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)

7QSOIHIRWMX] to VDE0482 part268-1 and
2, test methodC, IEC61034-1/61034-2,
HD606 and BS7622 part1 and2
(DINVDE0472 part816)

Application
These halogen-free, cross-linked and temperature resistant wiring and control cables with enhanced fire-behaviour properties are used for
wiring up the lighting fixtures, heaters, electric machines (temperature class B), switching systems and distribution switchboards. A very
long service life is also given on account of their excellent high-temperature stability.
These cables exhibit good resistance to weathering as well as being very stable to temperature, moisture, ozone and UV radiation. These
cables are therfore mainly used for traffic control systems and diverse outdoor applications. The development of smoke is low and no
corrosive gases are liberated during combustion of these halogen-free cables in case of fire. The risk of toxic fumes is considerably less in
the event of fire because the coloric load values is lower. Precious time can thus be won for a disciplined evacuation, and unnecessary loss
of life can be prevented. The extent of the damage to costly control and monitoring systems and the concrete and steel structures of
buildings and plant due to fire is reduced by this. Injuries to persons and damage to materials can be prevented. A lower conductor
cross-section is possible in certain circumstances because of the high thermal load and thus savings in the space and weight required can
be made. These wiring and control cables provide a significant contribution in safety engineering and environmental protection.
EMC = Electromagnetic compatibillity
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
52194

No.cores x
cross-sec.
mm
2x0,25

Outer
approx. mm
5,0

Cop.
weight
kg/km
16,0

Weight
approx.
kg/km
36,0

AWG-No.
24


Part no.
52195

No.cores x
cross-sec.
mm
3x0,25

Outer
approx. mm
5,5

Cop.
weight
kg/km
21,0

Weight
approx.
kg/km
44,0

AWG-No.
24

Continuation

E 14
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTHERM 145 MULTI-C


Cu-screened,
Part no.
52196
52197
52198
52199
52200
52201
52202
52203
52204
52205
52206
52207
52208
52209
52210
52211
52212
52213
52214
52215
52216
52217
52218
52219
52220
52221
52222
52223
52224
52225
52226
52227
52228
52229
52230
52231
52232
52233
52234
52235
52236
52237
52238
52239
52240

flexible, cross-linked, halogen-free,

EMC-preferred type, meter marking 

No.cores x
cross-sec.
mm
5x0,25
7x0,25
1x0,5
2x0,5
3x0,5
4x0,5
5x0,5
6x0,5
7x0,5
8x0,5
10x0,5
12x0,5
14x0,5
16x0,5
19x0,5
21x0,5
1x0,75
2x0,75
3x0,75
4x0,75
5x0,75
6x0,75
7x0,75
8x0,75
10x0,75
12x0,75
14x0,75
16x0,75
19x0,75
21x0,75
1x1
2x1
3x1
4x1
5x1
6x1
7x1
8x1
10x1
12x1
14x1
16x1
19x1
21x1
1x1,5

Outer
approx. mm
6,4
7,5
3,7
5,6
6,1
6,7
7,3
7,9
8,4
9,0
10,0
10,0
11,0
11,7
12,8
13,5
4,0
6,6
6,9
7,6
8,3
8,9
9,9
10,6
11,5
11,5
12,2
12,9
14,5
15,3
4,2
7,0
7,4
8,1
8,9
9,5
10,5
11,4
12,5
12,5
13,5
14,3
16,2
17,0
4,8

Cop.
weight
kg/km
29,0
37,0
15,0
29,0
38,0
45,0
51,0
66,0
68,0
80,0
93,0
107,0
122,0
129,0
158,0
167,0
18,0
38,0
50,0
58,0
70,0
85,0
90,0
110,0
140,0
148,0
167,0
183,0
212,0
230,0
20,0
31,0
56,0
66,0
95,0
105,0
109,0
130,0
138,0
164,0
198,0
203,0
235,0
257,0
22,0

Weight
approx.
kg/km
68,0
95,0
24,0
55,0
64,0
78,0
95,0
106,0
122,0
138,0
161,0
170,0
193,0
216,0
253,0
281,0
29,0
71,0
82,0
100,0
117,0
135,0
158,0
178,0
207,0
220,0
250,0
282,0
335,0
370,0
33,0
78,0
92,0
112,0
134,0
164,0
192,0
219,0
254,0
270,0
308,0
350,0
447,0
492,0
42,0

AWG-No.
24
24
20
20
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16

Part no.
52241
52242
52243
52244
52245
52246
52247
52248
52249
52250
52251
52252
52253
52254
52255
52256
52257
52258
52259
52260
52261
52262
52263
52264
52265
52266
52267
52268
52269
52270
52271
52272
52273
52274
52275
52276
52277
52278
52279
52280
52281
52282
52283
52284
52285
52286
52287
52288
52289
52290
52291
52292

No.cores x
cross-sec.
mm
2x1,5
3x1,5
4x1,5
5x1,5
6x1,5
7x1,5
8x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
21x1,5
1x2,5
2x2,5
3x2,5
4x2,5
5x2,5
6x2,5
7x2,5
8x2,5
10x2,5
12x2,5
14x2,5
16x2,5
19x2,5
21x2,5
1x4
2x4
3x4
4x4
5x4
6x4
7x4
8x4
10x4
12x4
14x4
1x6
2x6
3x6
4x6
5x6
6x6
7x6
1x10
2x10
3x10
4x10
5x10
6x10
7x10

Outer
approx. mm
8,2
8,7
9,4
10,5
11,5
12,6
13,7
15,0
15,0
16,0
17,0
19,3
20,3
5,6
9,8
10,4
11,5
12,6
13,8
15,3
16,5
18,3
18,3
19,6
20,7
23,5
24,4
6,3
10,9
11,5
12,8
14,3
15,6
17,0
18,3
20,7
20,7
22,1
6,9
12,1
12,8
14,3
16,0
17,4
19,3
8,4
15,1
16,4
18,1
20,2
22,3
24,3

Cop.
weight
kg/km
58,0
71,0
86,0
104,0
118,0
136,0
172,0
193,0
222,0
272,0
285,0
331,0
367,0
28,0
96,0
146,0
150,0
200,0
227,0
235,0
265,0
326,0
376,0
428,0
480,0
557,0
606,0
56,0
135,0
178,0
220,0
259,0
302,0
355,0
392,0
480,0
557,0
636,0
81,0
175,0
240,0
305,0
441,0
473,0
505,0
124,0
265,0
370,0
485,0
610,0
715,0
820,0

Weight
approx.
kg/km
105,0
121,0
156,0
188,0
225,0
264,0
308,0
361,0
383,0
458,0
515,0
639,0
705,0
59,0
148,0
183,0
221,0
273,0
326,0
397,0
475,0
542,0
582,0
681,0
778,0
948,0
1042,0
86,0
196,0
248,0
316,0
376,0
452,0
555,0
655,0
767,0
829,0
948,0
108,0
255,0
330,0
429,0
536,0
624,0
751,0
170,0
409,0
550,0
715,0
882,0
1026,0
1195,0

AWG-No.
16
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14
14
14
14
14
14
14
12
12
12
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10
8
8
8
8
8
8
8

Dimensions and specifications may be changed without prior notice. (RE01)

E 15
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SiHF/GL-P silicon mulitcore cable, steel braiding, halogen-free




Technical data

Cable structure

Special silicone multicore cable with higher


heat-resistance range adapted to
DINVDE0250 part1 and part816
Temperature range
-60 C to +180 C
(up to +220 C for short time)
Temperature limit at the conductor
in operation +180 C
Nominal voltage U0/U 300/500 V
Test voltage 2000 V
Breakdown voltage min. 5000 V
Insulation resistance
min. 200 MOhm x km
Power rating
at ambient temperature up to +145 C to
DINVDE0100 for higher temperatures
valid:
150 C - load value 100%
155 C - load value 91%
160 C - load value 82%
165 C - load value 71%
170 C - load value 58%
175 C - load value 41%
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 20x106 cJ/kg (up to 20 Mrad)

Tinned copper conductors fine wire to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Silicone core insulation
Core colours according
DIN VDE 0293-308
Core colour
- up to 5 cores one-coloured
- up 6 and more cores, black with white
numbering
- 3 and above, with green-yellow earth core
- 2 cores without green-yellow earth core
Cores stranded in layers with optimal
lay-length 
Outer jacket of silicone
Jacket colour preferably redbrown
Glass fibre tape over the jacket
Galvanized steel wire outer braiding

Properties

Advantages
Hardly changes of dielectric strength and
the insulation resistance also at high
temperatures, high ignition or flash point,
in case of fire, forms an insulating layer of
SiO2
Resistant to
High molecular oils, fats from vegetables
and animals, alcohols, plasticizers and
clophenes, diluted acids, lyes and salt
dissolution, oxidation substances, tropical
influences and weather, lake water, oxygen
Corrosivity of combustion gases
(Halogen-free)
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Behaviour in fire
no flame propagation
test according to VDE 0482-332-1-2, DIN
EN 60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
For laying as a fixed installation only in open
or ventilated pipe systems as well as in
ducts. Otherwise the mechanical properties
of the silicon are reduced by the enclosed
air at temperatures exceeding 90 C


Note

G = with green-yellow earth core;


x = without green-yellow earth core.


Application
Silicone cables screened with steel braiding were evolved for use wherever insulation is subjected to extreme temperature changes. They
are heat-resistant for permanent temperature up to +180 C, for short time operation up to +220 C. The good performance of the
environmental resistant properties means that silicone cables can be used at temperatures down to -60 C. Silicone cables are halogen-free
cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation
industry, ship building as well as in ceramic, glass and cement factories.
The screened steel braiding ensures a disturbance-free transmission of signals and impulses.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
23062
23063
23064
23065
23067
23068
23069
23070
23071
23073
23074
23075
23076
23077
23078
23079
23080
23081
23082
23083

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
2x1
3G1
4G1
5G1
7G1
2x1,5
3G1,5
4G1,5
5G1,5
6G1,5
7G1,5
8G1,5
12G1,5
14G1,5
18G1,5

Outer
approx. mm
7,9
8,3
9,3
10,0
10,7
8,0
8,9
9,4
10,4
11,1
9,0
9,5
10,3
11,0
12,0
12,0
13,0
15,5
16,2
18,7

Cop.
weight
kg/km
14,4
21,6
29,0
36,0
50,0
19,0
29,0
38,0
48,0
67,0
29,0
43,0
58,0
72,0
86,0
101,0
115,0
173,0
202,0
259,0

Weight
approx.
kg/km
90,0
101,0
129,0
157,0
177,0
97,0
122,0
141,0
166,0
197,0
127,0
145,0
173,0
202,0
240,0
244,0
261,0
327,0
382,0
440,0

AWG-No.
18
18
18
18
18
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16


Part no.
23084
23085
23086
23087
23088
23089
23090
23091
23092
23093
23094
23095
23096
23097
23098
23099
23100
23101
23102
23103

No.cores x
cross-sec.
mm
24G1,5
2x2,5
3G2,5
4G2,5
5G2,5
6G2,5
7G2,5
2x4
3G4
4G4
5G4
7G4
2x6
3G6
4G6
5G6
7G6
4G10
4G16
4G25

Outer
approx. mm
21,5
10,7
11,2
12,1
13,3
14,3
14,4
12,5
13,0
15,0
16,0
17,5
15,1
15,9
18,0
19,4
20,7
22,1
26,1
30,4

Cop.
weight
kg/km
346,0
48,0
72,0
96,0
120,0
144,0
168,0
77,0
115,0
154,0
192,0
269,0
115,0
173,0
230,0
288,0
403,0
384,0
614,0
960,0

Weight
approx.
kg/km
600,0
187,0
205,0
278,0
322,0
351,0
380,0
240,0
311,0
384,0
454,0
633,0
321,0
432,0
544,0
656,0
768,0
925,0
1235,0
1700,0

AWG-No.
16
14
14
14
14
14
14
12
12
12
12
12
10
10
10
10
10
8
6
4

Dimensions and specifications may be changed without prior notice. (RE01)

E 16
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SiHF-C-Si

silicon multicore cable, halogen-free, Cu-screened, EMC-preferred type,

meter marking


Technical data

Cable structure

Properties

Special silicone-insulated cable with higher


heat-resistance adapted to DINVDE0250
part1 and part816
Temperature range
-60 C to +180 C
(+220 C for short time)
Temperature limit at the conductor
in operation +180 C
Nominal voltage U0/U 300/500 V
Test voltage 2000 V
Breakdown voltage min. 5000 V
Insulation resistance
min. 200 MOhm x km
Power rating
at ambient temperatures up to +145 C
according to DINVDE0100
150 C - load value 100%
155 C - load value 91%
160 C - load value 82%
165 C - load value 71%
170 C - load value 58%
175 C - load value 41%
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 20x106 cJ/kg (up to 20 Mrad)

Tinned copper conductor fine wire


according to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Core insulation of silicone
Core colours according DIN VDE 0293-308
Core colour
- up to 5 cores one-coloured
- up 6 and more cores, black with white
numbering
- 3 and above, with green-yellow earth core
- 2 cores without green-yellow earth core
Cores stranded in layers with optimal
lay-length
Inner sheath of silicone
Braid of tinned Cu wires, coverage approx.
85%
Silicone-rubber-insulated common outer
jacket
Jacket preferentially redbrown colour
with meter marking, change-over in 2011

Resistant to
High molecular oils, fats from vegetables
and animals, alcohols, plasticizers and
clophenes, diluted acids, lyes and salt
dissolution, oxidation substances, tropical
influences and weather, lake water, oxygen
and UV
Halogen-free
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Burning behaviour
no propagation of fire
testing according to VDE 0482-332-1-2, DIN
EN 60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
For laying as a fixed installation only in open
or ventilated pipe systems as well as in
ducts. Otherwise the mechanical properties
of the silicon are reduced by the enclosed
air at temperatures exceeding 90 C.


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analoguetype:
SiHF see page E 7

Application
Silicone-rubber-insulated cables are used for all applications where the cable insulation is subjected to high temperature fluctuations. These
cables are heat-resistant for continuous use at temperatures up to +180 C, as well as for short periods of time at +220 C.
Silicone-rubber-insulated cables can also be used at low temperatures down to -60 C because of the excellent weathering resistance of the
material. These cables are halogen-free and hence are particularly suitable for applications in iron and steel works, rolling mills, foundries,
in aircraft construction and ship building, as well as in cement, glass and ceramic plants. Silicone-rubber-insulated cables have demonstrated
proven applications in projector and high-power lighting fixtures as well as all types of heating equipment.
An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone
multicore flexible cable for such applications as given above.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
23151
23152
23153
23154
23155
23156
23157
23158
23159
23291

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
10G0,5
12G0,5
16G0,5
18G0,5
25G0,5

Outer
approx. mm
8,0
8,3
9,1
9,9
10,9
12,8
13,5
15,1
15,9
18,5

Cop.
weight
kg/km
55,5
60,8
66,5
81,6
92,2
124,0
134,4
170,2
181,0
230,1

Weight
approx.
kg/km
101,0
118,0
131,0
153,0
173,0
242,0
263,0
326,0
351,0
348,0

AWG-No.
20
20
20
20
20
20
20
20
20
20


Part no.
23160
23161
23162
23163
23164
23165
23166
23167
23168
23292

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
10G0,75
12G0,75
16G0,75
18G0,75
25G0,75

Outer
approx. mm
9,0
9,4
10,4
11,3
12,0
13,9
15,2
16,9
18,0
20,8

Cop.
weight
kg/km
61,4
69,1
86,7
95,2
113,3
165,2
180,3
212,2
282,1
297,4

Weight
approx.
kg/km
124,0
136,0
159,0
180,0
212,0
306,0
333,0
418,0
453,0
468,0

AWG-No.
18
18
18
18
18
18
18
18
18
18

Continuation

E 17
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SiHF-C-Si

silicon multicore cable, halogen-free, Cu-screened, EMC-preferred type,

meter marking

Part no.
23169
23170
23171
23172
23173
23174
23175
23176
23177
23293
23178
23179
23180
23181
23182
23183
23184
23185
23186
23294

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
10G1
12G1
16G1
18G1
25G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
10G1,5
12G1,5
16G1,5
18G1,5
25G1,5

Outer
approx. mm
9,4
9,8
11,1
12,0
12,7
14,7
15,8
17,4
18,5
21,8
10,8
11,2
12,0
12,8
13,6
14,7
15,8
17,4
20,6
24,2

Cop.
weight
kg/km
66,7
86,2
96,8
108,3
141,2
190,0
209,8
251,8
297,4
329,0
87,7
103,5
131,7
148,5
193,4
268,5
298,4
362,3
394,0
488,2

Weight
approx.
kg/km
132,0
153,0
173,0
202,0
243,0
238,0
371,0
468,0
526,0
559,0
172,0
198,0
235,0
281,0
345,0
482,0
531,0
662,0
720,0
791,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16


Part no.
23187
23188
23189
23190
23191
23192
23193
23150
23194
23195
23196
23197
23198

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
4G4
5G4
2x6
4G6
5G6
4G10
4G16
4G25

Outer
approx. mm
12,0
12,9
13,8
14,8
15,8
16,0
17,4
15,8
18,1
20,0
23,2
25,2
31,0

Cop.
weight
kg/km
122,3
147,7
188,6
214,9
265,7
294,0
374,0
171,0
449,0
563,0
759,0
1180,0
1810,0

Weight
approx.
kg/km
230,0
275,0
340,0
394,0
488,0
520,0
653,0
350,0
781,0
982,0
1294,0
1988,0
2995,0

AWG-No.
14
14
14
14
14
12
12
20
10
10
8
6
4

Dimensions and specifications may be changed without prior notice. (RE01)

Conduits
Corrugated tubes
for standard applications
for lager sizes
scissile corrugated tubes
conduit glands
High exible conduits
plastic conduits with spiral spring
metal conduits
conduits glands
Conduit for heavy mechanical duty
metal conduits with plastic sheat
plastic conduits
conduits glands for metal conduits

You can nd conduits in our catalogue Cable Accessories.

E 18
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

THERMFLEX 180 EWKF-C

silicone multicore cable, Cu-screened,

halogen-free, +180C, EMC-preferred type, meter marking




Technical data

Cable structure

Properties

in adapted to DINVDE0250 part816


Temperature range
flexing -25 C to +180 C
fixed installation -60 C to +180 C
(short time operation +220 C)
Nominal voltage U0/U 300/500 V
Test voltage 2000 V
Insulation resistance
min. 200 MOhm x km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 20x106 cJ/kg (up to 20 Mrad)
Insulation integrity continuance of
insulation effects under fire condition
according to IEC60331 and DINVDE0472
part814
Halogen-free
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Behaviour in fire no flame propagation,
test according to DINVDE0482
part265-2-1/ EN50265-2-1/ IEC60332-1
(equivalent DINVDE0472 part804 test
methodB)

Tinned copper conductor, stranded to


DINVDE0295, cl.5, BS6360 cl.5 and
IEC60228 cl.5
Silicone core insulation, EI2to DINVDE0207
part20
Core identification to DINVDE0293-308
up to 5cores one-coloured,
6 and more cores black with white
numbering
Green-yellow earth core (3 cores and above)
Cores stranded in layers with optimal
lay-length
Special silicone inner sheath
Tinned copper braided screaning, covering
approx. 85%
Silicone outer jacket, 2GM1 to DINVDE0207
part21
Jacket colour black (RAL9005)
with meter marking, change-over in 2011

Smoke density - low


Due to the special abrasive and notch
resistance outer jacket, these cables are
suitable for heavy loading of mechanical
stresses than the usual standard silicone
cables
Hardly changes of dielectric strength and
the insulation resistance also at high
temperatures
High ignition or flash point
In case of fire, forms an insulating layer of
SiO2
Resistant to
High molecular oils, fats from vegetables
and animals, alcohols, plasticizers and
clophenes, diluted acids, lyes and salt
dissolution, oxidation substances, tropical
influences and weather, lake water, oxygen,
ozone


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
EWKF = Improved values to E=tearing
resistance, W=breaking strength
propagation, K=notch strength,
F=flexibility
unscreened analogue type:
THERMFLEX 180 EWKF
see page E 9

Application

These cables are ideal for use everywhere, where increased mechanical stresses for the installation and operation are required.
Silicone-rubber-insulated cables are used for all applications where the cable insulation is subjected to high temperature fluctuations. Suitable
for installation at high temperature influence in dry, damp and in the open air. As flexible connecting cable for low mechanical stress i.e.
sauna, solar installations, foundries and steel plants. This cable can be used for fixed installation only in open and ventilated cable tubes and
cable ducts. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected
silicone multicore flexible cable for such applications as given above.
EMC = Electromagnetic compatibillity
FRNC = Flame Retardant Non Corrosive
All silicon cables are available also in FRNC versions. The jacket designed with special-compound conform flame test method C to DINVDE0472
part804 and IEC60332-3 as well as HD405.3. This special compound is self-extinguishing. Because of that these cables can be installed as
security cable with functionality as for example in communal buildings, power stations, hotels, airports etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
79804
79805
79806
79807
79808
79809
79810
79811
79812
79813
79814
79815
79816
701219

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
2x1
3G1
4G1
5G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5

Outer
approx. mm
9,0
9,4
10,4
11,2
9,4
9,8
10,7
11,6
10,8
11,2
12,0
12,8
13,6
17,2

Cop.
weight
kg/km
61,4
69,1
86,7
95,2
66,7
86,2
96,8
108,3
87,7
103,5
131,7
148,5
193,4
298,4

Weight
approx.
kg/km
124,0
136,0
160,0
180,0
132,0
154,0
176,0
207,0
170,0
190,0
231,0
282,0
342,0
531,0

AWG-No.
18
18
18
18
17
17
17
17
16
16
16
16
16
16


Part no.
79817
79818
79819
79820
79821
79822
79823
79824
79825
79826
79827
79828
79829
79830

No.cores x
cross-sec.
mm
16G1,5
20G1,5
2x2,5
3G2,5
4G2,5
5G2,5
2x4
3G4
4G4
5G4
2x6
3G6
4G6
5G6

Outer
approx. mm
20,0
21,3
12,0
12,9
13,9
14,8
14,2
14,9
16,0
17,4
15,8
16,6
18,1
20,0

Cop.
weight
kg/km
362,3
405,1
122,3
147,7
188,6
214,9
137,0
178,1
294,0
374,0
185,0
241,1
449,0
563,0

Weight
approx.
kg/km
660,0
766,0
230,0
275,0
340,0
395,0
308,0
364,0
511,0
630,0
418,0
612,0
781,0
980,0

AWG-No.
16
16
14
14
14
14
12
12
12
12
10
10
10
10

Dimensions and specifications may be changed without prior notice. (RE01)

E 19
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTITHERM 400 -ES halogen-free, high-grade steel braiding




Technical data

Cable structure

Special core insulation for high


temperatures
Temperature range
-60 C to +400 C
Permissible temperature
+200 C to +400 C
(up to +500 C for short time)
Nominal voltage 500 V
Test voltage 2500 V
Minimum bending radius
approx. 5x cable

Cu wires, finely stranded, nickel plated


(ASTM B 355)
Core insulation of braided glass-fibre
impregnated with silicone
Second core insulation of glass-fibre
braiding impregnated with silicone
Overall lay up of cores
Core identification according to colour
coding listed below
Common outer sheath of glass-fibre
braiding impregnated with silicone
Sheath colour grey
Overall screen of braided high-grade steel,
coverage approx. 80%


Properties

Asbestos and cadmium-free


Colour code
No. of cores with protective earth
conductor
3 = gn-ye/bl/bn
4 = gn-ye/bk/bl/bn
5 = gn-ye/bk/bl/bn/wh
6 = gn-ye/bk/bl/bn/wh/rd
7 = gn-ye/bk/bl/bn/wh/rd/gy
No. of cores without protective earth
conductor
2 = bk/bn
3 = bk/bl/bn
4 = bk/bl/bn/wh
5 = bk/bl/bn/wh/rd
6 = bk/bl/bn/wh/rd/gy
7 = bk/bl/bn/wh/rd/gy/gn


Note

Please enquire for further configurations


and core cross sections for your
requirements.
unscreened analogue type:
MULTITHERM 400
see page E 13

Application

Where extremely high connecting and ambient temperatures occur, e.g. in iron and steel works, rolling mills, foundries, glass and ceramic
plants, in power plant construction, in the chemical industry, nuclear technology, crude oil engineering, in technical applications in medicine,
as well as for wiring resistances in electrical heating equipment, furnaces and machinery in thermoplastic forming. Due to the special
construction of the cable, a maximum temperature of approx. 220 C is recommended for use in damp environments. Applications at
temperatures above this should be used in dry environments only. The robust braiding of high-grade steel protects the cable from aggressive
atmospheres and mechanical stresses. The braided screen can also be used for earthing purposes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.cores x Outer


cross-sec. approx.
mm
mm
52018
52019
52020
52021
52022
52023
52024
52025
52026
52027
52028
52029
52030
52031
52032
52033
52034
52035
52036
52037
52038
52039
52040
52041
52042
52043
52044
52045

2 x 0,5
3 x 0,5
4 x 0,5
5 x 0,5
6 x 0,5
7 x 0,5
2 x 0,75
3 x 0,75
4 x 0,75
5 x 0,75
6 x 0,75
7 x 0,75
2x1
3x1
4x1
5x1
6x1
7x1
2 x 1,5
3 x 1,5
4 x 1,5
5 x 1,5
6 x 1,5
7 x 1,5
2 x 2,5
3 x 2,5
4 x 2,5
5 x 2,5

7,1
7,3
8,4
8,9
9,5
9,6
7,6
7,9
8,9
9,7
10,4
10,6
7,8
8,7
9,2
10,0
10,7
10,9
8,9
9,2
10,0
10,9
11,6
11,9
10,1
10,6
11,5
12,7

Cop.
weight
kg/km
10,0
15,0
19,0
25,0
30,0
34,0
14,4
21,6
29,0
36,0
43,0
50,0
19,0
29,0
38,0
48,0
58,0
67,0
29,0
43,0
58,0
72,0
88,0
101,0
48,0
72,0
96,0
120,0

Max. permiss.
current
carrying
capacity
at +340C (A)
3,3
3,1
3
2,9
2,8
2,7
5,1
5,1
4,9
4,7
4,5
4,4
7
6,7
6,4
6,2
6
5,8
9,4
9
8,6
8,3
8
7,8
12,2
11,6
11,2
10,8

Weight
approx.
kg/km

AWG-No.

84,0
89,0
111,0
126,0
146,0
158,0
95,0
109,0
131,0
157,0
177,0
190,0
105,0
126,0
148,0
174,0
198,0
212,0
132,0
153,0
183,0
212,0
241,0
259,0
191,0
213,0
256,0
307,0

20
20
20
20
20
20
18
18
18
18
18
18
17
17
17
17
17
17
16
16
16
16
16
16
14
14
14
14


Part no. No.cores x Outer
cross-sec. approx.
mm
mm
52046
52047
52048
52049
52050
52051
52052
52053
52054
52055
52056
52057

6 x 2,5
7 x 2,5
2x4
3x4
4x4
5x4
7x4
3x6
4x6
5x6
4 x 10
4 x 16

14,9
15,1
11,9
12,3
15,1
15,6
16,6
16,3
18,3
19,8
22,1
26,6

Cop.
weight
kg/km
144,0
168,0
77,0
115,0
154,0
192,0
270,0
173,0
230,0
288,0
384,0
615,0

Max. permiss.
current
carrying
capacity
at +340C (A)
10,4
10,1
16
15,3
14,6
14,1
13,3
20
19
18
26
34

Weight
approx.
kg/km
359,0
388,0
260,0
303,0
378,0
458,0
593,0
442,0
567,0
671,0
866,0
1203,0

AWG-No.

14
14
12
12
12
12
12
10
10
10
8
6

Dimensions and specifications may be changed without prior notice. (RE01)

E 20
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Allweather and Rubber Cables

F1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Allweather and Rubber Cables


HELUKABEL supply mainly from stock light,
middle and heavy rubber cables, drum cables with
polyurethane or neoprene outer jacket, elevator
control cables with central or external support
cores, connecting cables for submersible pumps
and other special cables.
One of the biggest stocks of special cables in
Germany makes this possible with a fast delivery
time.
Our well trained sales team with long term
experience and the latest technology know how
to solve your cable problems.
Because of the permanent developments and
tests it is possible for HELUKABEL to manufacture
cables with the newest and proven materials.
We would like to construct and manufacture
your cable.

F2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description
YELLOWFLEX,cold flexible, robust, meter marking ........................................................................................................................................
H05 RR-F / H05 RN-F,rubber-sheathed cable..................................................................................................................................
H07 RN-F,rubber-sheathed cable, harmonized type ........................................................................................................................

A07 RN-F,rubber-sheathed cable, authorised national type ....................................................................................................................

NEOPREN Command Cable,flexible, colour or number coded with support organ............................................................................................

LIFT-TRAGO-30 / -60,lift hoist control cable, pendal length 30m resp. 60m .......................................................................................................
TRAGO / Lift-2S,Lift and Hoist Control Cables 300/500V .................................................................................................................................
H07 ZZ-F,control cable, cross linked, halogen-free ....................................................................................................................................

NSSHU,heavy duty rubber cable for mining working, 0,6/1kV .....................................................................................................................

Page
F 4
F 5
F 6
F 8
F 9

F 10
F 11
F 12
F 14

F3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

YELLOWFLEX

cold flexible, robust, meter marking

Technical data

Cable structure

Properties

Rubber sheathed cable acc. to


DINVDE0282 Part4, HD22.4S4
Temperature range
flexing -25 C to +60 C
fixed installation -30 C to +60 C
Permissible operating temperature
at conductor +60 C
Nominal voltage U0/U 450/750 V
with protected fixed installation
U0/U 600/1000 V
Highest permissible operating voltage
in three-phase and one-phase
a.c. systems U0/U 476/825 V
in d.c. systems U0/U 619/1238 V
Test voltage 2500 V
Minimum bending radius
for fixed installation 4x cable
for guiding over roller 7,5x cable
during winding on drums 5-7x cable

Bare copper conductor, fine wire to


DINVDE0295 cl.5, BS6360 cl.5, IEC60228
cl.5 and/or HD383
Rubber core insulation, EI4 to DIN VDE 0282
part 1
Core colours according
DIN VDE 0293-308
Core colour
- up to 5 cores one-coloured
- up 6 and more cores, black with white
numbering
- 3 and above, with green-yellow earth
core
- 2 cores without green-yellow earth core
Cores stranded in layers with optimal
lay-length
Special outer sheath, EM2 to
DIN VDE 0282 part 1
Sheath colour Yellow (RAL 1021)
with meter marking, change-over in 2011
Individual printing:
Article numbers for individual printing:
Art.No. 37359 for 3G1,5 mm
Art.No. 37360 for 3G2,5 mm
Art.No. 37361 for 5G1,5 mm
Art.No. 37362 for 5G2,5 mm
Usual length:
500m or 1000m drum
Minimum quantity
500m drum
price for 500m drum 102,25 Euro
price for 1000m drum 153,40 Euro


Tests
Flame-retardant acc. to VDE 0482-332-1-2,
DIN EN 60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Increased stability
Tear-resistant
Resistant to
Atmospheric influences
Hydrolysis
UV-radiation
Largely resistant to
Oils and fats
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
individual marking

Application
These robust rubber sheathed cables can be used where high demands are placed flexibility and mechanical stress. For application on
construction sites, in steel works and rolling mills in heating and air-conditioning systems, in the bottling industry, in machinery and plant
construction, in the chemical industry and painting systems, as well as for the professional and the hobby enthusiast. The choice of yellow
as the sheath colour ensures additional safety. Can be used in potentially explosive areas acc. to DINVDE0165.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
37259
37260
37261
37262
37263
37264
37265
37266
37267
37268
37269
37270
37271
37272

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
2x2,5
3G2,5
4G2,5
5G2,5

Outer
approx. mm
8,4
9,2
9,7
11,0
9,2
9,8
11,5
12,0
16,5
18,3
11,0
11,8
12,7
14,1

Cop.
weight
kg/km
19,0
29,0
38,0
48,0
29,0
43,0
58,0
72,0
101,0
175,0
48,0
72,0
96,0
120,0

Weight
approx.
kg/km
98,0
131,0
150,0
220,0
135,0
165,0
200,0
241,0
375,0
460,0
194,0
235,0
290,0
347,0

AWG-No.
17
17
17
17
16
16
16
16
16
16
14
14
14
14


Part no.
37273
37274
37275
37276
37277
37278
37279
37280
37281
37282
37283
37284
37285
37286

No.cores x
cross-sec.
mm
2x4
3G4
4G4
5G4
4G6
5G6
4G10
5G10
4G16
5G16
4G25
5G25
4G35
5G35

Outer
approx. mm
13,0
14,1
15,8
17,1
18,2
19,1
23,0
25,8
26,3
29,1
31,7
35,2
36,8
40,6

Cop.
weight
kg/km
77,0
115,0
154,0
192,0
230,0
288,0
384,0
480,0
614,0
768,0
960,0
1200,0
1344,0
1680,0

Weight
approx.
kg/km
282,0
322,0
397,0
486,0
541,0
652,0
952,0
1203,0
1260,0
1550,0
1860,0
2250,0
2374,0
2752,0

AWG-No.
12
12
12
12
10
10
8
8
6
6
4
4
2
2

Dimensions and specifications may be changed without prior notice. (RF01)

Also available as pre-assembled cable - see page U 52.

F4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H05 RR-F / H05 RN-F

rubber-sheathed cable

Technical data

Cable structure

Properties

To DINVDE0282 part4,
HD22.4S4 IEC60245-4
H05 RR-F zustzlich nach BS 6500
Temperature range
-30 C to +60 C
Permissible operating temperature
at conductor +60 C
Nominal voltage U0/U 300/500 V
Max. operating voltage
three-phase and one-phase a.c.
U0/U 318/550 V
for direct current U0/U 413/825 V
Test voltage 2000 V
Minimum bending radius
approx. 7,5x cable

Bare copper conductors, fine stranded to


DINVDE0295 cl.5, BS6360 cl.5, IEC60228
cl.5 and HD383
Rubber core insulation EI4 to DINVDE0282
part1
Cores laid up
Cores colour coded to DINVDE0293-308
Outer jacket black:
RR-F = Rubber, EM 3 to DINVDE0282 part1
RN-F = EM 2 to DINVDE0282 part1


Oils and fats are allowed to come in touch


Tests
Behaviour on fireaccording to VDE
0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
H05RR-F is replaced the former type NLH
and NMH up to 2,5 mm.
H05RN-F is replaced to former type
NMHU up to 1 mm.
at 1,5 mm - not in VDE; adapted to VDE
(H)05RN-F
Art.no. 36008 = national type: A-05RN-F
Art-no. 36007 = (A)05RN-F, outer jacket
colour grey, for window shades
manufacturer

Application
H05 RR-F
These cables are suitable for connecting electrical appliances, for example vacuum cleaner, flat irons, soldering irons, kitchen appliances,
toaster, stoves etc. They were also used for medium mechanical stress in households and offices. These cables are suitable for fixed installation
in partition walls, furniture, decoration covering and in hollow spaces of prefabricated building parts.
They are notsuitable for use in open air, in industries (also permitted to tailor workshops and of that kind) or in agriculture plants and for
connecting commercial electrical tools.
H05 RN-F
These cables are suitable for connecting electrical equipment with low mechanical stress in dry, damp and wet places as well in open air, for
example as connection cable for horticulture tools. These cables can be used in contact with fats and oils (for example deep fryer).
They are also suitable for fixed installation, for example in furniture, decoration covering, partition walls and in hollow spaces of prefabricated
building parts. The installation in hazardous areas is allowed.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


H05 RR-F
Part no.
35001
35005
35009
35019
35002
35006
35010
35020
35003
35007
35011
35013
35004
35008
35012
35014
35015
35017
35016
35018

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
2x1
3G1
4G1
5G1
2x1,5
3G1,5
4G1,5
5G1,5
2x2,5
3G2,5
4G2,5
5G2,5
3G4
4G4
3G6
4G6

Outer
min. - max.
mm
5,7 - 7,4
6,2 - 8,1
6,8 - 8,8
7,6 - 9,9
6,1 - 8,0
6,5 - 8,5
7,1 - 9,3
8,0 - 10,3
7,6 - 9,8
8,0 - 10,4
9,0 - 11,6
9,8 - 12,7
9,0 - 11,6
9,6 - 12,4
10,7 - 13,8
11,9 - 15,3
11,3 - 14,5
12,7 - 16,2
12,8 - 16,3
14,2 - 18,1

Cop.
weight
kg/km
14,4
21,6
29,0
36,0
19,0
29,0
38,0
48,0
29,0
43,0
58,0
72,0
48,0
72,0
96,0
120,0
115,0
154,0
173,0
230,0

Weight
approx.
kg/km
60,0
74,0
78,0
99,0
72,0
85,0
98,0
134,0
98,0
120,0
150,0
180,0
145,0
170,0
220,0
270,0
260,0
340,0
361,0
462,0

AWG-No.
18
18
18
18
17
17
17
17
16
16
16
16
14
14
14
14
12
12
10
10

H05 RN-F
Part no.
36001
36003
36007
36008
36002
36004
36005
36006

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
4G0,75
2x1
3G1
3G1,5
5G1,5

Outer
min. - max.
mm
5,7 - 7,4
6,2 - 8,1
6,8 - 8,8
6,8 - 8,8
6,1 - 8,0
6,5 - 8,5
8,6 - 11,0
10,5 - 13,5

Cop.
weight
kg/km
14,4
21,6
29,0
29,0
19,0
29,0
43,0
72,0

Weight
approx.
kg/km
78,0
94,0
90,0
90,0
94,0
114,0
157,0
228,0

AWG-No.
18
18
18
18
17
17
16
16

Dimensions and specifications may be changed without prior notice. (RF01)

F5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H07 RN-F

rubber-sheathed cable, harmonized type

Technical data

Cable structure

Rubber sheathed cable H07 RN-F to


DINVDE0282 part4, HD22.4S4, BS7919
IEC60245-4
Temperature range
-30 C to +60 C
Permissible operating temperature
at conductor +60 C
Nominal voltage U0/U 450/750 V
in case of protected and fixed installation
U0/U 600/1000 V
Max. permissible operating voltage in
three phase and one phase a.c. system
U0/U 476/825 V
direct current-system U0/U 619/1238 V
Test voltage 2500 V
Permanent tensile load
max. 15 N/mm
Minimum bending radius
for fixed installation 4x cable
for guiding over roller 7,5x cable
during winding on drums 5-7x cable

Copper conductor fine wire stranded, bare


to DINVDE0295 cl.5, BS6360 cl.5,
IEC60228 cl.5 and HD383
Rubber core insulation EI4 to DINVDE0282
part1
Insulation thickness to DINVDE0282 part4
Core identification to DINVDE0293-308
Core colours
-up to 5 cores one-coloured
-6 and more cores, black with numbering
-3 and above, with green-yellow earth core
-2 cores without green-yellow earth core
Cores stranded in layers with optimal
lay-length
Outer jacket of rubber black, rubber
compound to DINVDE0282 part1
Sheath thickness to DINVDE0282 part4

Properties

Resistant to
Weather
Test
Test according to VDE 0482-332-1-2, DIN
EN 60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Ozone resistant of the insulation to
DINVDE0472 part805, test method A or
part 805A1, test methodC
Oil resistant
Test according to EN 60811-2-1


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Further dimensions and cross-sections
available on request.
H07 RN-F = harmonized rubber-sheathed
cable, working voltage 750 V, fine stranded.
The core identification of a single core
jacketed, of an insulated wire is black.
For application as a protective core, the
ends are to be identified with green-yellow
and the middle conductor with light blue

Application
Heavy duty rubber-sheathed flexible cables are suited for use for medium mechanical stress in dry, damp and wet areas as well as in open
air and in agriculture plants.
They are used for equipment in industry works such as boilers, heating plates, hand lamps, electric tools such as drills, circular saws and
homework tools as well as for transportable motors or machines at site.
These cables are also suitable for fixed installation on plaster, in temporary buildings and residential barracks. They are suitable for direct
laying on components and mechanical parts of machines, for example lifts and cranes.
They can be used in case of protected and fixed installation in tubes or in equipment as well as rotor connecting cable of motors with a
working voltage up to 1000V alternating voltage or a direct voltage up to 750V against ground. The operating direct voltage is permitted
up to 900V against ground when they are used in rail-coaches. Installation in hazardous areas according to DINVDE0165 is allowed.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
37001
37002
37003
37004
37005
37006
37007
37008
37009
37010
37011
37012
37013
37014
37015
37016
37017
37018
37019
37020

No.cores x
cross-sec.
mm
1x1,5
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
2x1
2x1,5

Outer
min. - max.
mm
5,7 - 7,1
6,3 - 7,9
7,2 - 9,0
7,9 - 9,8
9,5 - 11,9
10,8 - 13,4
12,7 - 15,8
14,3 - 17,9
16,5 - 20,6
18,6 - 23,3
20,8 - 26,0
22,8 - 28,6
25,2 - 31,4
27,6 - 34,4
30,6 - 38,3
33,5 - 41,9
37,4 - 46,8
41,3 - 52,0
7,7 - 10,0
8,5 - 11,0

Cop.
weight
kg/km
14,4
24,0
38,0
58,0
96,0
154,0
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0
1776,0
2304,0
2880,0
3840,0
4800,0
19,0
29,0

Weight
approx.
kg/km
58,0
71,0
100,0
130,0
230,0
290,0
420,0
530,0
750,0
960,0
1250,0
1560,0
1900,0
2300,0
2950,0
3600,0
4600,0
6000,0
98,0
135,0

AWG-No.
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
17
16


Part no.
37021
37022
37023
37024
37025
37026
37027
37028

No.cores x
cross-sec.
mm
2x2,5
2x4
2x6
2x10
2x16
2x25
3G1
3G1,5

Outer
min. - max.
mm
10,2 - 13,1
11,8 - 15,1
13,1 - 16,8
17,7 - 22,6
20,2 - 25,7
24,3 - 30,7
8,3 - 10,7
9,2 - 11,9

Cop.
weight
kg/km
48,0
77,0
115,0
192,0
307,0
480,0
29,0
43,0

Weight
approx.
kg/km
193,0
280,0
330,0
586,0
810,0
1160,0
130,0
165,0

AWG-No.
14
12
10
8
6
4
17
16

Continuation

F6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H07 RN-F

rubber-sheathed cable, harmonized type

Part no.
37029
37030
37031
37032
37033
37034
37035
37036
37037
37038
37039
37040
37041
37042
37043
37044
37045
37046
37047
37048
37049
37050
37051
37052
37053
37054
37055

No.cores x
cross-sec.
mm
3G2,5
3G4
3G6
3G10
3G16
3G25
3G35
3G50
3G70
3G95
3G120
3G150
3G185
3G240
3G300
4G1
4G1,5
4G2,5
4G4
4G6
4G10
4G16
4G25
4G35
4G50
4G70
4G95

Outer
min. - max.
mm
10,9 - 14,0
12,7 - 16,2
14,1 - 18,0
19,1 - 24,2
21,8 - 27,6
26,1 - 33,0
29,3 - 37,1
34,1 - 42,9
38,4 - 48,3
43,3 - 54,0
47,4 - 60,0
52,0 - 66,0
57,0 - 72,0
65,0 - 82,0
72,0 - 90,0
9,2 - 11,9
10,2 - 13,1
12,1 - 15,5
14,0 - 17,9
15,7 - 20,0
20,9 - 26,5
23,8 - 30,1
28,9 - 36,6
32,5 - 41,1
37,7 - 47,5
42,7 - 54,0
48,4 - 61,0

Cop.
weight
kg/km
72,0
115,0
173,0
288,0
461,0
720,0
1008,0
1440,0
2016,0
2736,0
3456,0
4320,0
5328,0
6192,0
8640,0
38,0
58,0
96,0
154,0
230,0
384,0
614,0
960,0
1344,0
1920,0
2688,0
3648,0

Weight
approx.
kg/km
235,0
320,0
420,0
810,0
1050,0
1250,0
1900,0
2600,0
3400,0
4450,0
5180,0
6500,0
7860,0
10224,0
12620,0
150,0
200,0
290,0
395,0
540,0
950,0
1260,0
1860,0
2380,0
3190,0
4260,0
5600,0

AWG-No.
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
17
16
14
12
10
8
6
4
2
1
2/0
3/0


Part no.
37056
37057
37058
37059
37060
37061
37062
37063
37064
37065
37066
37067
37068
37091
37154
34090
34349
37092
37079
37093
37096
37097
37094
37098
37095
37099

No.cores x
cross-sec.
mm
4G120
4G150
4G185
4G240
4G300
5G1,5
5G2,5
5G4
5G6
5G10
5G16
5G25
5G35
5G50
5G70
5G95
5G120
7G1,5
7G2,5
12G1,5
12G2,5
18G2,5
19G1,5
19G2,5
24G1,5
24G2,5

Outer
min. - max.
mm
53,0 - 66,0
58,0 - 73,0
64,0 - 80,0
72,0 - 91,0
80,0 - 101,0
11,2 - 14,4
13,3 - 17,0
15,6 - 19,9
17,5 - 22,2
22,9 - 29,1
26,4 - 33,3
32,0 - 40,4
36,8 - 45,8
40,0 - 50,8
43,8 - 54,0
51,7 - 60,7
59,6 - 68,6
14,5 - 17,5
16,5 - 20,0
17,6 - 22,4
20,6 - 26,2
24,4 - 30,9
20,7 - 26,3
25,5 - 31,0
24,3 - 30,7
28,8 - 36,4

Cop.
weight
kg/km
4608,0
5760,0
7104,0
9216,0
11520,0
72,0
120,0
192,0
288,0
480,0
768,0
1200,0
1680,0
2400,0
3360,0
4560,0
5760,0
101,0
168,0
175,0
288,0
432,0
274,0
456,0
346,0
576,0

Weight
approx.
kg/km
6830,0
8320,0
9800,0
12100,0
15200,0
240,0
345,0
485,0
650,0
1200,0
1550,0
2250,0
2750,0
3950,0
4740,0
6600,0
8180,0
375,0
520,0
460,0
760,0
850,0
810,0
1075,0
1015,0
1390,0

AWG-No.
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
16
14
12
10
8
6
4
2
1
1
14
14
16
14
16
14
14
16
14
16
14

Dimensions and specifications may be changed without prior notice. (RF01)

F7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

A07 RN-F

rubber-sheathed cable, authorised national type

Technical data

Cable structure

Properties

Rubber sheathed cable A07RN-F to


DINVDE0282 part4
Temperature range
-30 C to +60 C
Permissible operating temperature
at conductor +60 C
Nominal voltage U0/U 450/750 V
in case of protected and fixed installation
U0/U 600/1000 V
max. permissible operating voltage in
three phase and one phase a.c. system
U0/U 476/825 V
direct current-system U0/U 619/1238 V
Test voltage 2500 V
Permanent tensile load
max. 15 N/mm under consideration of
total copper cross-sections
Minimum bending radius
for fixed installation 4x cable
for guiding over roller 7,5x cable
during winding on drums 5-7x cable

Copper conductor fine wire stranded, bare


to DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Rubber core insulation EI4 to DINVDE0281
part1
Insulation thickness to DINVDE0282 part4
Core identification to DINVDE0293-308
Core colours:
6 and more cores green-yellow and the
other cores black with numbering
Cores stranded in layers in optimal
lay-length
Outer jacket of rubber black, rubber
compound to DINVDE0281 part1
Sheath thickness to DINVDE0282 part4

Resistant to
Weather
Test
Behaviour in fire to DINVDE0482
part265-2-1/ EN50265-2-1/ IEC60332-1
(equivalent DINVDE0472 part804 test
methodB)
Ozone resistant of the insulation to
DINVDE0472 part805, test methodA or
part805A1, test methodC


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
A07 RN-F = Authorized national
rubber-sheathed cable, nominal voltage
750 V, fine wire stranded.
Valid for design with central core + 7 cores.
The core identification of a single core
jacketed, of an insulated wire is black.
For application as a protective core, the
ends are to be identified with green-yellow
and the middle conductor with light blue.

Application
Heavy duty rubber-sheathed flexible cables are suited for use for medium mechanical stress in dry, damp and wet areas as well as in open
air and in agriculture plants.
They are used for equipment in industry works such as boilers, heating plates, hand lamps, electric tools such as drills, circular saws and
homework tools as well as for transportable motors or machines at site.
These cables are also suitable for fixed installation on plaster, in temporary buildings and residential barracks. They are suitable for direct
laying on components and mechanical parts of machines, for example lifts and cranes.
They can be used in case of protected and fixed installation in tubes or in equipment as well as rotor connecting cable of motors with a
working voltage up to 1000V alternating voltage or a direct voltage up to 750V against ground. The operating direct voltage is permitted
up to 900V against ground when they are used in rail-coaches. Installation in hazardous areas according to DINVDE0165 is allowed.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


A07 RN-F (with green-yellow protective conductor)


Part no.
37069
37070
37071
37072
37078
37073
37074
37075
37076
37077

No.cores x
cross-sec.
mm
7G1,5
7G2,5
12G1,5
12G2,5
19G1,5
19G2,5
24G2,5
27G1,5
27G2,5
37G2,5

Outer
min. - max.
mm
14,0 - 17,5
16,5 - 20,0
17,6 - 22,4
20,6 - 26,2
25,0 - 29,5
21,5 - 25,5
28,8 - 36,4
25,5 - 31,5
30,0 - 37,0
34,0 - 37,5

Cop.
weight
kg/km
101,0
168,0
173,0
288,0
274,0
456,0
576,0
385,0
640,0
720,0

Weight
approx.
kg/km
370,0
500,0
520,0
720,0
1100,0
800,0
1350,0
1100,0
1521,0
1940,0

AWG-No.
16
14
16
14
14
16
14
16
14
14

A07 RN-F (without green-yellow protective conductor)


Part no.
37080
37081
37082
37083
37084
37085
37086
37087
37088
37089
37090

No.cores x
cross-sec.
mm
3x1,5
3x2,5
3x4
3x6
3x10
3x16
3x25
3x35
3x50
4x10
4x25

Outer
min. - max.
mm
9,2 - 11,9
10,9 - 14,0
12,7 - 16,2
14,1 - 18,0
19,1 - 24,2
21,8 - 27,6
26,1 - 33,0
29,3 - 37,1
34,1 - 42,9
20,9 - 26,5
28,9 - 36,6

Cop.
weight
kg/km
43,0
72,0
115,0
173,0
288,0
461,0
720,0
1008,0
1440,0
384,0
960,0

Weight
approx.
kg/km
165,0
235,0
320,0
495,0
880,0
1095,0
1450,0
1900,0
2600,0
1065,0
1995,0

AWG-No.
16
14
12
10
8
6
4
2
1
8
4

Dimensions and specifications may be changed without prior notice. (RF01)

F8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NEOPREN Command Cable

flexible, colour or number coded with

support organ


Technical data

Cable structure

Properties

Special neoprene cable adapted to


DINVDE0250 part807 and
DINVDE0282 part807 and 808
With strain bearing support strand
Temperature range
flexing -25 C to +60 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Minimum bending radius
for continuous bending without forced
guiding operation 12,5xcable
for flexing with forced guiding operation
20xcable

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295, cl.6, col.4,
BS6360 cl.6 and IEC60228
Core insulation of rubber
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core
Cores stranded in layers with optimal
lay-length
Support organ (hemp or sisal-string etc.),
and/or taping with load carrying thread as
construction permits
Neoprene outer jacket, colour black
A further selection of sizes and dimensions
is available on request.


Generally oil, flat and alkali resistant




Note

G = with green-yellow earth core;


x = without green-yellow earth core.
Not suitable for a winding up and an
unwinding on spring or motor cable reels.
Break resistance must be taken into
consideration.
By the assembly the cables must be
installed without torsion. The mobility of
the stranded core is not be affected by
using of clamps.
The occuring pulling forces are to be
carried by the support organ.

Application
As robust and weather resistant cable for machines, equipment and appliances, which are constantly exposed to the outdoor weather
conditions (e.g. building machinery, conveyor and hoist systems, dry docks etc.). They are ideal for use as control cable in trailing cables.
They are also suitable in dry, damp and wet areas for wall- and push-button panels and as power cable.
The core insulation is ozone resistant and the outer jacket made of chloroprene is hardly flammable and abrasion resistant.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.cores x


cross-sec.
mm
25001
25002
25003
25004
25005
25006
25007
25008
25009
25010
25011
25012
25013
25074
25014
25015
25016
25017
25018
25019
25020
25021
25022
25023
25024
25025
25026
25027
25028
25029
25030
25031
25032
25033
25034
25035
25036
25037
25038
25039
25040

2x1
3G1
4G1
5G1
6G1
7G1
9G1
12G1
16G1
18G1
19G1
20G1
24G1
30G1
36G1
37G1
48G1
50G1
54G1
61G1
2x1,5
3G1,5
4G1,5
5G1,5
6G1,5
7G1,5
8G1,5
9G1,5
10G1,5
11G1,5
12G1,5
13G1,5
15G1,5
18G1,5
19G1,5
24G1,5
37G1,5
42G1,5
48G1,5
50G1,5
61G1,5

Outer
approx.
mm
7,5
8,5
9,7
11,5
13,4
13,8
15,8
17,5
19,2
21,5
22,0
22,4
23,6
24,6
29,0
30,5
31,4
32,6
32,9
37,2
8,5
9,3
10,5
12,5
14,3
14,8
15,8
17,7
18,5
20,1
21,6
22,1
22,8
23,6
24,1
27,0
31,0
33,0
34,9
36,7
41,8

Tensile
strength
of susp.
strand in N
300
150
300
300
2290
2890
6740
570
960
600
2890
960
1440
2500
2290
300
150
570
870
2600
3460
3850
450
7710
680
960
860
3850
3460
-

Cop.
weight
kg/km
19,0
29,0
38,0
48,0
58,0
67,0
86,0
115,0
154,0
173,0
182,0
192,0
230,0
290,0
346,0
355,0
461,0
480,0
518,0
586,0
29,0
43,0
58,0
72,0
86,0
101,0
115,0
130,0
144,0
158,0
173,0
187,0
216,0
259,0
274,0
346,0
533,0
605,0
691,0
720,0
878,0

Weight
approx.
kg/km

AWG-No.

90,0
111,0
141,0
170,0
187,0
204,0
274,0
389,0
432,0
471,0
565,0
590,0
650,0
785,0
910,0
936,0
1244,0
1296,0
1399,0
1495,0
95,0
113,0
150,0
180,0
245,0
309,0
333,0
360,0
405,0
458,0
516,0
571,0
590,0
620,0
670,0
817,0
1220,0
1380,0
1510,0
1642,0
1950,0

17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16


Part no. No.cores x
cross-sec.
mm
25041
25042
25043
25044
25045
25046
25075
25047
25048
25049
25050
25051
25052
25053
25054
25055
25056
25057
25058
25059
25060
25061
25062
25063
25064
25065
25066
25067
25068
25069
25070
25071
25072
25073

2x2,5
3G2,5
4G2,5
5G2,5
6G2,5
7G2,5
8G2,5
9G2,5
11G2,5
12G2,5
16G2,5
18G2,5
19G2,5
24G2,5
36G2,5
37G2,5
48G2,5
50G2,5
61G2,5
3G4
4G4
5G4
7G4
3G6
4G6
5G6
7G6
3G10
4G10
5G10
7G10
3G16
4G16
5G16

Outer
approx.
mm
10,0
10,5
11,6
12,9
14,5
16,2
16,8
21,5
23,3
25,4
24,4
26,3
27,5
30,5
33,3
40,8
41,9
43,3
49,3
13,6
15,0
17,1
21,5
13,9
15,2
19,2
21,1
18,1
20,6
22,6
27,4
21,3
25,2
26,5

Tensile
strength
of susp.
strand in N
300
300
570
380
3460
3850
680
6060
2290
6060
2500
1000
600
1000
900
1200
1500
1920
2400

Cop.
weight
kg/km

Weight
approx.
kg/km

48,0
72,0
96,0
120,0
144,0
168,0
192,0
216,0
264,0
288,0
383,0
432,0
456,0
576,0
864,0
888,0
1152,0
1200,0
1464,0
115,0
154,0
192,0
269,0
173,0
230,0
288,0
403,0
288,0
384,0
480,0
672,0
461,0
614,0
768,0

142,0
172,0
210,0
255,0
318,0
383,0
450,0
541,0
638,0
690,0
813,0
891,0
946,0
1221,0
1737,0
1784,0
2500,0
2630,0
8100,0
372,0
407,0
432,0
495,0
380,0
445,0
569,0
702,0
530,0
724,0
923,0
1288,0
865,0
1028,0
1260,0

AWG-No.

14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
12
12
12
12
10
10
10
10
8
8
8
8
6
6
6

Dimensions and specifications may be changed without prior notice. (RF01)

F9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LIFT-TRAGO-30 / -60

lift hoist control cable, pendal length 30m resp. 60m

Technical data

Cable structure

Properties

Lift hoist control cables with strain bearing


element to IEC60227-6 edition 2001-06
and adapted to DINVDE0281 part13
Temperature range
flexing -5 C to +50 C
fixed installation -40 C to +70 C
Max. conductor temperature
under load +70 C
circuit conditions +150 C
Nominal voltage
U0/U 300/500 V
Test voltage 3000 V
Breakdown voltage
min. 6000 V
Minimum bending radius
approx. 20x cable
Insulation resistance
min. 20 MOhm x km
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Special PVC core insulation, TI2 to
DINVDE0281 part1
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
Cores stranded with optimal lay-length
according to the number of cores in one
or two layers, over a central suspension
strand of textile.
LIFT-TRAGO-30 - Fleece wrapping
LIFT-TRAGO-60 - Support braiding of textile
suspension strands
Outer sheath of special PVC, TM2 to
DINVDE0281 part1
Colour black (RAL9005)

Extensively oil resistant


Chemical Resistance - see table Technical
Informations
The PVC-outer sheath is oil resistant
according to DINVDE0281 part1
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core.


AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Cable for pendal length 60 m and above
available on request.

Application
These cables are used as control or feeder cables in lifts and hoists.
30 m pendal length - LIFT-TRAGO-30
60 m pendal length - LIFT-TRAGO-60
Suspension height for medium mechanical stresses in dry and moist rooms.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


LIFT-TRAGO-30
Part no.
25259
25260
25261
25262

No.cores x
cross-sec.
mm
7G1
12G1
18G1
24G1

Outer
approx. mm
11,5
15,7
16,1
19,2

Cop.
weight
kg/km
67,0
115,0
173,0
230,0

Weight
approx. kg/km

Cop.
weight
kg/km
67,0
115,0
173,0
230,0
288,0
346,0

Weight
approx. kg/km

170,0
325,0
390,0
530,0

Support core
Textile
Textile
Textile
Textile

Pendal
length
app. m

AWG-No.
30
30
30
30

17
17
17
17

LIFT-TRAGO-60
Part no.
25263
25264
25265
25266
25267
25268

No.cores x
cross-sec.
mm
7G1
12G1
18G1
24G1
30G1
36G1

Outer
approx. mm
12,3
16,2
16,7
19,8
22,5
28,2

185,0
335,0
400,0
540,0
690,0
930,0

Support core
Textile
Textile
Textile
Textile
Textile
Steel

Pendal
length
app. m

AWG-No.
60
60
60
60
60
60

17
17
17
17
17
17

Dimensions and specifications may be changed without prior notice. (RF01)

F 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRAGO / Lift-2S

Lift and Hoist Control Cables 300/500V

Technical data

Cable structure

Properties

Lift hoist control cables with strain bearing


element
Special PVC-compound for core and jacket,
adapted to DINVDE0250
Temperature range
flexing -15 C to +40 C
fixed installation -40 C to +70 C
Max. conductor temperature
under load +70 C
circuit conditions +150 C
Nominal voltage
U0/U 300/500 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Free suspension height max. 50 m
Minimum bending radius
approx. 20x cable

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.6, BS6360
cl.6 and IEC60228 cl.6
Special PVC core insulation, YI3 to
DINVDE0207 part4
Core coding to DINVDE0293
Green-yellow earth core
Special hemp support braid
for Trago type with central support core
of hemp
for Lift-2S type with 2 outer steel support
wires
Cores stranded in layers with optimal
lay-length
Multi-layer wrapping functioning as a
support braid
Special PVC outer jacket YM2 to
DINVDE0207 part5
Colour black (RAL9005)

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

Art.no. 25090 - C = 2 cores 0,5 mm with


copper braiding.
Art.no. 25101 = 7G1 + 17x0,75 mm.
G = with green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
These cables are used as control or feeder cables in lifts and hoists. The special attention given to both production and material quality for
these cables has made them ideal even for use under extreme conditions.
HELUKABEL-Lift-2S has also proven itself to be ideally suited for installation in conveyor systems and manual control units.
The external steel support wires can be dismounted without damaging the cable insulation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


TRAGO with central support


Part no.
25080
25081
25082
25083
25101
25084
25085
25086
25087
25088
25090
25089

No.cores x
cross-sec.
mm
7G0,75
12G0,75
18G0,75
24G0,75
7G1
7G1
12G1
18G1
20G1
24G1
28G1
36G1

Outer
approx. mm
15,4
19,2
21,0
23,0
21,5
14,9
20,0
21,4
21,6
23,2
26,0
26,1

Cop.
weight
kg/km
50,0
86,0
130,0
173,0
190,0
67,0
115,0
173,0
192,0
230,0
293,0
346,0

Weight
approx. kg/km

Cop.
weight
kg/km
115,2
172,8
240,0
288,0
115,0
172,8
230,0
259,0
288,0
346,0

Weight
approx. kg/km

290,0
360,0
455,0
535,0
595,0
222,0
415,0
450,0
490,0
605,0
760,0
950,0

Support core
Hemp
Hemp
Hemp
Hemp
Hemp
Hemp
Hemp
Hemp
Hemp
Hemp
Hemp
Hemp

Pendal
length
app. m
250
220
110
90
90
80
80
70
70
60
90
90

AWG-No.

Pendal
length
app. m

AWG-No.

18
18
18
18
17
17
17
17
17
17
17
17

Lift-2S with 2 external support cores


Part no.
25091
25092
25093
25094
25095
25096
25097
25098
25099
25100

No.cores x
cross-sec.
mm
12G1
18G1
25G1
30G1
8G1,5
12G1,5
15G1,5
18G1,5
20G1,5
24G1,5

Outer
approx. mm
13,5
16,2
19,0
21,9
14,7
16,0
19,5
19,3
19,5
22,5

446,0
528,0
660,0
760,0
425,0
505,0
575,0
640,0
715,0
820,0

Support core
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel

17
17
17
17
16
16
16
16
16
16

Dimensions and specifications may be changed without prior notice. (RF01)

F 11
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H07 ZZ-F

control cable, cross linked, halogen-free

Technical data

Cable structure

Properties

halogen-free cross-linked control cable to


DINVDE0282 part13, HD22.13S1+A1
Temperature range
flexing -5 C to +70 C
fixed installation -20 C to +70 C
Permissible operating temperature
at conductor +70C
Nominal voltage
fixed installation U0/U 06/1 kV
flexing U0/U 450/750 V
Test voltage 2500 V
Permanent tensile load
max. 15 N/mm under consideration of
total copper cross-sections
Minimum bending radius
for fixed installation 4x cable
flexing10x cable

Bare copper, fine wire stranded conductor


to DINVDE0295 cl.5, BS6360 cl.5, and
IEC60228 cl.5 and HD383
Core insulation cross-linked, halogen-free,
EI8 to DINVDE0282 part1 (HD22.1S3)
Core colours to DINVDE0293-308
Cores stranded in layers with optimal
lay-lengt
Outer jacket, cross-linked halogen-free EM8
to DINVDE0282 part1 (HD22.1S3)
Sheath colour black

Test
Behaviour in fire to EN50265-2-1 (VDE0472
part804) and HD405.3 cat.C
Corrosiveness of combustion gases to
EN50267-2-2
Smoke density to HD606
Ozone resistant of single corethe insulation
to EN60811-2-1, HD22.2


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Single and multicore sheathed cable, with low smoke and corrosive gas production in case of fire for interior use.
Not suitable for continuous outside use. In this case, cable with a special tested covering should be used.
Skin contact should be avoided when the cable is used in high temperatures.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
37176
37177
37178
37179
37180
37181
37182
37183
37184
37185
37186
37187
37188
37189
37190
37191
37192
37193
37194
37195
37196
37197
37198
37199
37200
37201

No.cores x
cross-sec.
mm
1x1,5
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
2x1
2x1,5
2x2,5
2x4
2x6
2x10
2x16
2x25

Outer
min. - max.
mm
5,7 - 7,1
6,3 - 7,9
7,2 - 9,0
7,9 - 9,8
9,5 - 11,9
10,8 - 13,4
12,7 - 15,8
14,3 - 17,9
16,5 - 20,6
18,6 - 23,3
20,8 - 26,0
22,8 - 28,6
25,2 - 31,4
27,6 - 34,4
30,6 - 38,3
33,5 - 41,9
37,4 - 46,8
41,3 - 52,0
7,7 - 10,0
8,5 - 11,0
10,2 - 13,1
11,8 - 15,1
13,1 - 16,8
17,7 - 22,6
20,2 - 25,7
24,3 - 30,7

Cop.
weight
kg/km
14,4
24,0
38,0
58,0
96,0
154,0
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0
1776,0
2304,0
2880,0
3840,0
4800,0
19,0
29,0
48,0
77,0
115,0
192,0
307,0
480,0

Weight
approx.
kg/km
58,0
71,0
100,0
130,0
230,0
290,0
420,0
530,0
750,0
960,0
1250,0
1560,0
1900,0
2300,0
2950,0
3600,0
4600,0
6000,0
95,0
119,0
172,0
239,0
319,0
572,0
767,0
1154,0

AWG-No.
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
17
16
14
12
10
8
6
4


Part no.
37202
37203
37204
37205
37206
37207
37208
37209
37210
37211
37212
37213
37214
37215
37216
37217
37218

No.cores x
cross-sec.
mm
3G1
3G1,5
3G2,5
3G4
3G6
3G10
3G16
3G25
3G35
3G50
3G70
3G95
3G120
3G150
3G185
3G240
3G300

Outer
min. - max.
mm
8,3 - 10,7
9,2 - 11,9
10,9 - 14,0
12,7 - 16,2
14,1 - 18,0
19,1 - 24,2
21,8 - 27,6
26,1 - 33,0
29,3 - 37,1
34,1 - 42,9
38,4 - 48,3
43,3 - 54,0
47,4 - 60,0
52,0 - 66,0
57,0 - 72,0
65,0 - 82,0
72,0 - 90,0

Cop.
weight
kg/km
29,0
43,0
72,0
115,0
173,0
288,0
461,0
720,0
1008,0
1440,0
2016,0
2736,0
3456,0
4320,0
5328,0
6192,0
8640,0

Weight
approx.
kg/km
115,0
144,0
211,0
290,0
391,0
706,0
961,0
1438,0
1814,0
2550,0
3210,0
4423,0
5405,0
6725,0
8222,0
10224,0
12620,0

AWG-No.
17
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil

Continuation

F 12
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H07 ZZ-F

control cable, cross linked, halogen-free

Part no.
37219
37220
37221
37222
37223
37224
37225
37226
37227
37228
37229
37230
37231
37232
37233
37234
37235
37236
37237
37238
37239
37240
37241
37242
37243

No.cores x
cross-sec.
mm
4G1
4G1,5
4G2,5
4G4
4G6
4G10
4G16
4G25
4G35
4G50
4G70
4G95
4G120
4G150
4G185
4G240
4G300
5G1
5G1,5
5G2,5
5G4
5G6
5G10
5G16
5G25

Outer
min. - max.
mm
9,2 - 11,9
10,2 - 13,1
12,1 - 15,5
14,0 - 17,9
15,7 - 20,0
20,9 - 26,5
23,8 - 30,1
28,9 - 36,6
32,5 - 41,1
37,7 - 47,5
42,7 - 54,0
48,4 - 61,0
53,0 - 66,0
58,0 - 73,0
64,0 - 80,0
72,0 - 91,0
80,0 - 101,0
10,2 - 13,1
11,2 - 14,4
13,3 - 17,0
15,6 - 19,9
17,5 - 22,2
22,9 - 29,1
26,4 - 33,3
32,0 - 40,4

Cop.
weight
kg/km
38,0
58,0
96,0
154,0
230,0
384,0
614,0
960,0
1344,0
1920,0
2688,0
3648,0
4608,0
5760,0
7104,0
9216,0
11520,0
48,0
72,0
120,0
192,0
288,0
480,0
768,0
1200,0

Weight
approx.
kg/km
141,0
176,0
235,0
365,0
501,0
872,0
1194,0
1822,0
2307,0
3253,0
4130,0
5720,0
6965,0
8644,0
10598,0
12100,0
15200,0
170,0
214,0
316,0
448,0
607,0
1075,0
1480,0
2255,0

AWG-No.
17
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
17
16
14
12
10
8
6
4


Part no.
37244
37245
37246
37247
37248
37249
37250
37251
37252
37253
37254
37255
37256
37257
37258

No.cores x
cross-sec.
mm
6G1,5
6G2,5
6G4
7G1,5
7G2,5
12G1,5
12G2,5
12G4
18G1,5
18G2,5
18G4
24G1,5
24G2,5
36G1,5
36G2,5

Outer
min. - max.
mm
13,4 - 17,2
15,7 - 20,0
18,2 - 23,2
11,4 - 14,4
13,4 - 17,0
17,6 - 22,4
20,6 - 26,2
24,4 - 30,9
20,7 - 26,3
24,4 - 30,9
28,8 - 36,4
24,3 - 30,7
28,8 - 36,4
27,8 - 35,2
33,2 - 41,8

Cop.
weight
kg/km
84,0
144,0
230,0
101,0
168,0
173,0
288,0
461,0
259,0
432,0
691,0
346,0
576,0
518,0
864,0

Weight
approx.
kg/km
287,0
420,0
583,0
303,0
448,0
496,0
724,0
1042,0
702,0
1045,0
1430,0
935,0
1325,0
1297,0
1949,0

AWG-No.
16
14
12
16
14
16
14
12
16
14
12
16
14
16
14

Dimensions and specifications may be changed without prior notice. (RF01)

F 13
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NSSHU

heavy duty rubber cable for mining working, 0,6/1kV

Technical data

Cable structure

Properties

Rubber sheath cable to DINVDE0250


part812
Temperature range
flexing -25 C to +80 C
fixed installation -40 C to +80 C
Permissible operating temperature
at conductor +90 C
Nominal voltage U0/U 0,6/1 kV
Operating voltage
three-phase and one-phase a.c.
U0/U 0,7/1,2 kV
direct current system
U0/U 0,9/1,8 kV
Test voltage 3000 V
Insulation resistance
min. 20 MOhm x km
Tensile strength
statical load:
total cross-section x15 N/mm
Minimum bending radius
fixed installation 4x cable
flexing 10x cable
without forced operation 15x cable

Tinned copper conductor, fine wire


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Rubber insulation 3GI3 (EPR), to
DINVDE0207 part20
Green-yellow earth-core for 3-cores and
above
Core identification: one green-yellow earth
core and others black cores with
continuous white numbering to
DINVDE0293-308. The basic-line prohibits
confusion to recognise the individual cores.
Cores stranded (multi cores)
Rubber inner sheath, GM1b,
rubber-compound to DINVDE0207 part21
Outer jacket, rubber-compound 5GM5 to
DINVDE0207 part21
Colour yellow

Ozone resistance
High insulation resistance
Resistant against hot penetration
Low abrasion
High notch resistant
Resistant against
oils, fats and chemicals
Test of oil resistant to DINVDE0472
part803, test methodA
Behaviour in fire
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The code identification of a single core
jacketed of an insulated wire is black. For
application as a protective core, the ends
are to be identified with grenn-yellow and
the middle conductor with light blue.


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Are suited as a connecting cable for very high mechanical stress in underground mining and tools for use in industries and outdoor use.
They are also used for mining industry, surface mining, stone-pits, on building sites, outdoors as well as indoors. Suitable for fixed installation
on plaster in dry, damp and wet areas. A long duration of life is guaranteed under extreme operating conditions. Not suitable for drumming
and use in all types of machinery, such as robots, handling units and energy transfer units, where constant mobility is essential. The insulation
of a plastic-rubber compound on EPR basis improves the resistance to ozone in order to avoid the formation of cracks due to ozone and
insulation damages in switch-boards.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
38001
38002
38003
38004
38005
38006
38007
38008
38009
38010
38011
38012
38013
38014
38015
38016
38017
38018
38019
38020
38021
38022

No.cores x
cross-sec.
mm
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
2x2,5
3G1,5
3G2,5
3G4
3G6
4G1,5
4G2,5
4G4
4G6
4G10
4G16
4G25

Outer
approx. mm
11,5
14,5
15,5
18,0
20,5
23,0
25,0
28,0
30,0
33,0
13,2
12,5
14,0
16,8
18,1
16,0
19,0
21,5
23,0
27,5
37,0
39,0

Cop.
weight
kg/km
154,0
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0
1776,0
2304,0
48,0
43,0
72,0
115,0
173,0
58,0
96,0
154,0
230,0
384,0
614,0
960,0

Weight
approx.
kg/km
336,0
473,0
635,0
866,0
1145,0
1475,0
1832,0
2000,0
2450,0
3190,0
205,0
173,0
247,0
336,0
520,0
210,0
305,0
415,0
641,0
1113,0
1412,0
2095,0

AWG-No.
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
14
16
14
12
10
16
14
12
10
8
6
4


Part no.
38023
38024
38025
38026
38027
38028
38029
38030
38031
38035
38036
38037
38038
38032
38039
38033
38040
38034

No.cores x
cross-sec.
mm
4G35
4G50
4G70
4G95
4G120
5G1,5
5G2,5
5G4
5G6
5G10
5G16
5G25
7G1,5
7G2,5
10G1,5
12G2,5
18G2,5
19G2,5

Outer
approx. mm
42,5
49,0
53,5
61,5
68,0
17,0
20,0
23,0
26,5
30,0
34,0
42,0
19,5
21,5
19,8
28,0
33,0
29,2

Cop.
weight
kg/km
1344,0
1920,0
2688,0
3648,0
4608,0
72,0
120,0
192,0
288,0
480,0
768,0
1200,0
101,0
168,0
144,0
288,0
432,0
466,0

Weight
approx.
kg/km
2777,0
3817,0
5071,0
6636,0
7000,0
252,0
362,0
509,0
798,0
1120,0
1680,0
2430,0
470,0
546,0
560,0
851,0
1230,0
1260,0

AWG-No.
2
1
2/0
3/0
4/0
16
14
12
10
8
6
4
16
14
16
14
14
14

Dimensions and specifications may be changed without prior notice. (RF01)

F 14
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Trailing Cables

G1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Trailing Cables
Trailing cables are used for high mechanical stress,
especially for applications with frequent winding
and unwinding with simultaneous tensile and
torsional stress.

Trailing cables are frequently used in building


machinery, conveyors and lifting systems, and
cranes.

G2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description
TROMM-PUR-H,trailing, halogen-free .............................................................................................................................................

TROMM-PUR,PUR trailing and control cable, halogen-free ..............................................................................................................................


NSHTU,drum cable, VDE approved ......................................................................................................................................................

(N)SHTU-V,Trailing-Cable......................................................................................................................................................................

HELUSPREADER YSLT-J,spreader cable for vertical basket enterprise............................................................................................................


(N)TSCGEWU,extremely torsionally stiff....................................................................................................................................................

Page
G 4
G 5
G 6
G 7
G 8
G 9

G3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TROMM-PUR-H

trailing, halogen-free

Technical data

Cable structure

Properties

Trailing cable acc. to ULAWM Style20235


CSA/AWM
Temperature range
flexing -40 C to +80 C
fixed installation -50 C to +80 C
Nominal voltage
acc. to VDE 600/1000 V
acc. to UL 1000 V
A.c. test voltage, 50 Hz
core/core 4000 V
Insulation resistance
min. 20 MOhm x km
Tensile strength s. table
Speed of motion
up to 250 m/min
Minimum bending radius
approx. 6x cable

Bare copper, extra fine wire conductor to


VDE0295 cl.6 and IEC60228 cl.6
TPE core insulation
Core colours up to
5 cores acc. to DINVDE0293,
6 or more cores black with white numbers
+ gnye
Cores stranded around support element
Polyester fleece wrapping
High-tensile PUR double sheath with
integrated support braiding
Sheath colour yellow


PUR outer sheath, low adhesion, abrasion


resistant, halogen-free, resistant to UV, oil,
hydrolysis and microbial attack
PUR sheath: self-extinguishing and flame
retardant according to VDE0482-332-1-2,
DIN EN60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Due to the PUR outer jacket, the cable is
resistant against ozone and radiation, as
well as oils, greases and petrol

Application
Significantly smaller external diameters, smaller bending radii and reduced weights compared to NSHTU cables enable the use of smaller
drive motors and drums, thus providing significant cost savings.
> Trailing cables are used for high mechanical stress, especially for applications with frequent winding and unwinding with simultaneous
tensile and torsional stress, for building machinery, conveyors and lifting systems, and cranes. They are used as robust and all-weather
resistant cables in the harshest operating environments in mining and in flexible handling equipment and railway motors. The cables are
suitable for installation in dry, damp and wet environments, as well as outdoors.
Notes
During installation and operation the tensile stress on the cable must not exceed 15 N/mm
Acceleration must not exceed 0,4 m/sec
1 to 2 turns should remain on the drum during operation
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
77144
77145
77146
77147
77148
77149
77150
77151
77152
77153
77154
77155
77156
77157
77158
77159
77160

No.cores x
cross-sec.
mm
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
24G1,5
30G1,5
42G1,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
24G2,5
30G2,5
40G2,5
50G2,5

Outer
approx. mm
10,2
10,8
12,9
18,4
18,6
21,3
24,6
26,5
11,7
12,7
14,8
20,4
21,1
24,8
27,6
30,0
34,3

Cop.
weight
kg/km
58,0
72,0
101,0
173,0
259,0
345,6
432,0
604,8
96,0
120,0
168,0
288,0
432,0
576,0
720,0
960,0
1200,0

Weight
approx.
kg/km
157,0
176,0
245,0
337,0
526,0
662,0
901,0
1056,0
208,0
263,0
327,0
533,0
725,0
988,0
1242,0
1500,0
1800,0


Part no.
77161
77172
77162
77173
77163
77174
77164
77175
77165
77166
77167
77168
77169
77170
77171

No.cores x
cross-sec.
mm
4G4
5G4
4G6
5G6
4G10
5G10
4G16
5G16
4G25
4G35
4G50
4G70
4G95
4G120
4G150

Outer
approx. mm
12,5
14,3
16,9
17,8
19,6
20,9
23,8
25,3
27,7
30,1
35,2
40,3
50,6
53,0
56,0

Cop.
weight
kg/km
154,0
192,0
230,0
288,0
384,0
480,0
614,0
768,0
960,0
1344,0
1920,0
2688,0
3648,0
4608,0
5760,0

Weight
approx.
kg/km
270,0
362,0
409,0
511,0
633,0
766,0
936,0
1170,0
1485,0
2115,0
2600,0
3700,0
4800,0
5900,0
7100,0

Dimensions and specifications may be changed without prior notice.

G4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TROMM-PUR

PUR trailing and control cable, halogen-free

Technical data

Special PUR insulation and jacket


Adapted to DINVDE0250
Strain bearing support strand
Temperature range
-40 C to +80 C
(up to +100 C for short periods)
Nominal voltage
up to 1 mm U0/U 300/500 V
as of 1,5 mm U0/U 450/750 V
Test voltage
up to 1 mm = 2000 V
as of 1,5 mm = 2500 V
Breakdown voltage
up to 1 mm = 4000 V
as of 1,5 mm = 5000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
approx. 10x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Cable structure

Properties

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.6, col.4,
BS6360 cl.6 and IEC60228 cl.6
Special core insulation, PUR
Support core
Core coding to DINVDE0293 (flexible
cables)
Cores stranded in layers with optimal
lay-length
Core wrapping with fleece
Support braiding of synthetic fibres
Halogen-free outer jacket PUR
colour orange


High flexibility at low temperatures


Usable for foodstuffs
Abrasion and tear resistant
Loadable under torsional stress
Resistant to
Oils and fats
Non-alcoholic fuels and kerosene
Atmospheric influences
UV-radiation
Oxygen and ozone
Microbes and rotting
Sea and waste water
Vibrations


Note

G = with green-yellow earth core.


AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
TROMM-PUR has taken the development of the neoprene type cables one step further. It is a robust, all-weather cable, halogen-free, tear
and abrasion resistant and suitable for use in drag-chains, in ship docks, on building sites, for conveyor systems, in mining, for tunnels and
roadbuilding.
For the connecting the ski lift terminal positions to the control unit, surveillance of the joining rods in ski lift cables, as feeder cables for
very high currents as for example in pump engineering, mining, locomotive and rail-carriage construction, for oil rig platforms, emergency
power generators etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
26035
26036
26037
26038
26039
26040
26041
26042
26043
26044
26045
26046
26047
26048
26049
26050
26051
26052
26053
26054
26055
26059
26056
26057
26058

No.cores x
cross-sec.
mm
14G0,75
12G1
18G1
3G1,5
5G1,5
7G1,5
12G1,5
18G1,5
24G1,5
30G1,5
42G1,5
4G2,5
5G2,5
7G2,5
12G2,5
24G2,5
30G2,5
36G2,5
7G4
4G10
4G16
5G16
4G25
4G35
4G50

Outer
approx. mm
16,5
17,5
23,0
9,5
12,5
15,5
21,0
27,0
30,0
34,0
40,0
14,0
15,0
18,0
25,0
36,0
40,0
44,0
22,0
22,0
27,0
34,0
30,0
36,0
42,0

Cop.
weight
kg/km
154,0
115,0
173,0
43,0
72,0
101,0
173,0
259,0
346,0
533,0
605,0
96,0
120,0
168,0
288,0
576,0
864,0
998,0
269,0
384,0
614,0
768,0
960,0
1344,0
1920,0

Weight
approx. kg/km
320,0
300,0
480,0
110,0
220,0
270,0
450,0
620,0
850,0
1100,0
1600,0
250,0
280,0
360,0
740,0
1400,0
1740,0
2050,0
600,0
650,0
1100,0
1600,0
1600,0
2050,0
2800,0

Breaking strain
ca. kp
250
500
500
200
200
250
750
750
750
750
750
200
250
300
750
750
750
750
500
500
500
750
500
1000
1000

AWG-No.
18
17
17
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
12
8
6
6
4
2
1

Dimensions and specifications may be changed without prior notice. (RG01)

G5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NSHTU

drum cable, VDE approved

Technical data

Cable structure

Properties

Special-crane-drum cable to DINVDE0250


part814
Temperature range
flexing -35 C to +70 C
fixed installation -40 C to +70 C
Max. conductor temperature
under load +60 C
circuit conditions +200 C
Nominal voltage U0/U 0,6/1 kV
Max. permissiblenominal voltages
for three phase and one phase a.c.
current installation U0/U 0,7/1,2 kV
for direct current U0/U 0,9/1,8 kV
Test voltage 2500 V
Insulation resistance
min. 10 MOhm x km
Minimum bending radius
7,5x cable
Radiation resistance
up to 20x106 cJ/kg (up to 20 Mrad)

Tinned copper fine wire conductors, bunch


stranded to DIN VDE 0295 cl. 5, BS 6360 cl.
5 and IEC 60228 cl. 5
Rubber core insulation GI1 to DIN VDE 0207
part 20
Core identification to DIN VDE 0293, 6 cores
and above with numbering
Cores stranded (without elongated central
core) with max. lay-length of 8x over the
stranding layers
Textile tape
Textile braiding as protection against
torsion, embedded in inner filling sheath
Neoprene outer jacket, type 5GM2 to DIN
VDE 0207 part 21
Jacket colour black

Designed and developed for horizontal


drum-operation
Permissible running speed up to
120m/min max.
Polychloroprene-rubber (neoprene)-jacket,
extremely cold resistant
Behaviour in fire
Test according to 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Oil resistant
Test according to VDE0472 part803, test
methodA
Due to the neoprene outer jacket, the
cables is resistant against ozone and
radiation, oils, acids, fats, gazoline, solvents
and chemicals
During the installation and operation the
tensile stress on conductor may not
increase 15N/mm
Accelaration not more than 0,4m/sec
During operation, 1-2 convolutions should
remain on the operating drum
In case of high mechanical stress, especially
of high dynamic tensile stress result high
accelaration, the permissible stress must
be defined in each case


Note

G = with green-yellow earth core.


AWG sizes are approximate equivalent
values. The actual cross-section is in mm.


Application
Trailing cables are used for high mechanical stress, especially for applications with frequent winding and unwinding with simultaneous tensile
and torsional stress, for building machinery, conveyors, shifts and cranes.
They are used as robust and all weather resistant cables of roughest operations in mining and in flexible handling equipment and railway
motors. The cables are suitable for outdoor installation in dry, damp and wet places as well in open air.
For applications which go beyond standard solutions we recommend that you fill out our especially developed questionnaire for reeling
cables. Please read the installation instructions.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
26001
26029
26002
26003
26004
26005
26006
26007
26008
26009
26010
26011
26012
26013
26014
26015
26016
26017
26018

No.cores x
cross-sec.
mm
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
16G1,5
18G1,5
24G1,5
30G1,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
24G2,5
30G2,5
40G2,5
50G2,5

Outer
approx. mm
13,6
14,0
14,5
18,8
21,0
24,5
25,5
27,5
29,5
15,3
16,5
17,5
20,0
23,5
28,0
32,5
34,0
42,5
46,5

Cop.
weight
kg/km
47,0
58,0
81,0
115,0
196,0
259,0
271,0
390,0
432,0
74,0
98,0
124,0
168,0
308,0
451,0
615,0
770,0
1080,0
1200,0

Weight
approx.
kg/km
236,0
274,0
316,0
440,0
606,0
696,0
750,0
1150,0
1325,0
305,0
350,0
465,0
576,0
850,0
1181,0
1550,0
1810,0
3110,0
3200,0

AWG-No.
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14
14
14


Part no.
26019
26030
26020
26031
26021
26022
26023
26032
26024
26025
26026
26027
26028

No.cores x
cross-sec.
mm
4G4
5G4
4G6
5G6
4G10
5G10
4G16
5G16
4G25
4G35
4G50
4G70
4G95

Outer
approx. mm
18,5
21,5
21,0
23,5
26,0
28,0
29,0
31,5
35,0
37,5
44,5
49,0
56,0

Cop.
weight
kg/km
158,0
220,0
241,0
317,0
404,0
508,0
642,0
768,0
1005,0
1344,0
2010,0
2688,0
3648,0

Weight
approx.
kg/km
510,0
635,0
650,0
800,0
1010,0
1200,0
1300,0
1700,0
2000,0
2610,0
3500,0
4600,0
6100,0

AWG-No.
12
12
10
10
8
8
6
6
4
2
1
2/0
3/0

Dimensions and specifications may be changed without prior notice. (RG01)

G6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

(N)SHTU-V

Trailing-Cable

Technical data

Cable structure

Properties

Special trailing cable according to DIN VDE


0250, Part 814
Temperature range
Flexing -25 C to +80 C
Max. temperature at the conductor
during operation+90 C
on short-circuit+250 C
Nominal voltage
U0/U 0,6/1 kV
Maximum permitted operating voltages
in three-phase and one-phase alternating
current installations
U0/U 0,7/1,2 kV
Direct current installations 
U0/U 0,9/1,8 kV
Test voltage 4 kV
Insulation resistance
min. 10 MOhm x km
Minimum bending radius
7,5x cable

Tinned copper conductor, fine wire


stranded according to DIN VDE 0295 cl. 5,
BS 6360 cl. 5 or IEC 60228 cl. 5
Insulating sleeve from special rubber
compound 3GI3 in accordance with DIN
VDE 207 Part 20
Core identification in accordance with DIN
VDE 0293 Part 308 (HD 308 S2)
Cores stranded (without elongated central
core) with max. lay-length of 8 x over the
stranded layers)
Depending on dimension/structure with
Kevlar fillers
Inner sheath: Special rubber,
compound-type 5GM5
Torsion protection between inner and
outer sheath
Outer sheath from special rubber
compound, compound type 5GM5
according to DIN VDE 0207 Part 21
Sheath colour - yellow

Permitted running speed up 180 m/min


Fire behaviour
Test inaccordance with 0482-332-1-2, DIN
EN 60332-1-2/ IEC60332-1 (conforms to
DINVDE0472 Part804 Test methodB)
Oil resistant
Test in accordance with DIN EN 60811-2-1
IEC 60811-2-1
Highly resistant to acids, fats, gasoline,
solvents and chemicals
During installation and operation, the
tensile stress must not exceed 30 N/mm

Application
For vertical drum operation under extreme mechanical stress and on moving cable carrieres. Used as a rugged feeder to construction
machines, conveyor, transport and crane systems in dry, damp, wet environments and outdoors. For applications that go beyond standard
solutions we recommend you to our specially developed questionnaire for reeling cables. Please note installation instructions.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Power supply Cable


Part no. No.cores x
cross-sec.
mm
31040
3G1,5
31041
3G2,5
31042
3G4
31043
3G6
31044
3G10
31045
3G16
31046
3G25
31047
3 x 50 + 3G25
31048
3 x 70 + 3G35
31049
3 x 95 + 3G50
31050
3 x 120 + 3G70
31051
3 x 150 + 3G70
31052
3 x 185 + 3G95
31053
3 x 240 + 3G120
31054
4G1,5
31055
4G2,5
31056
4G4
31057
4G6
31058
4G10
31059
4G16
31060
4G25
31061
4G35
31062
4G50
31063
4G70
31064
4G95
31065
4G120
31066
4G150
31067
4G185
31068
5G1,5
31069
5G2,5
31070
5G4
31071
5G6
31072
5G10
31073
5G16
31074
5G25
31075
5G35
31076
5G50
31077
5G70

Outer
min. - max.
mm
10,9 - 13,6
12,3 - 14,8
14,9 - 17,6
16,2 - 18,9
19,6 - 22,6
21,8 - 24,9
27,5 - 30,8
36,9 - 40,6
40,4 - 44,4
46,6 - 50,8
50,8 - 55,2
55,4 - 60,0
60,8 - 65,7
68,8 - 74,0
11,8 - 14,5
14,4 - 17,1
16,2 - 18,8
17,4 - 20,2
24,4 - 21,3
24,7 - 27,9
31,4 - 34,9
37,5 - 33,9
40,3 - 44,2
44,5 - 48,6
51,1 - 55,5
57,4 - 62,0
62,6 - 67,6
68,1 - 73,2
12,8 - 15,5
15,5 - 18,2
17,4 - 20,2
19,6 - 22,7
23,2 - 26,3
26,7 - 30,2
34,1 - 37,7
38,3 - 42,2
43,8 - 47,8
50,2 - 54,6

Cop.
weight
kg/km
45,0
74,0
115,0
173,0
288,0
461,0
720,0
1685,0
2355,0
3215,0
4130,0
4990,0
6250,0
8065,0
58,0
99,0
158,0
241,0
404,0
642,0
1005,0
1344,0
2010,0
2687,0
3646,0
4605,0
5765,0
7110,0
73,0
124,0
220,0
317,0
508,0
768,0
1005,0
1344,0
2010,0
2688,0

Weight
approx.
kg/km
191,0
240,0
362,0
450,0
682,0
890,0
1200,0
2810,0
3760,0
4700,0
5950,0
7050,0
8800,0
11700,0
220,0
330,0
440,0
530,0
835,0
1175,0
1850,0
2250,0
3210,0
4210,0
5550,0
7010,0
8450,0
10000,0
258,0
389,0
511,0
688,0
1002,0
1395,0
2205,0
2960,0
3950,0
5455,0

Tensile
strain
max. N
130
220
360
540
900
1440
2250
4500
6300
8550
10800
13500
16650
21600
180
300
480
720
1200
1920
3000
4200
6000
8400
11400
14400
18000
22200
220
370
600
900
1500
2400
3750
5250
7500
10500

AWG-No.
-

Control Cable (Kevlar fillers)


Part no. No.cores x
cross-sec.
mm
31078
49G1
31079
7G1,5
31080
12G1,5
31081
18G1,5
31082
24G1,5
31083
30G1,5
31084
36G1,5
31085
44G1,5
31086
48G1,5
31087
56G1,5
31088
7G2,5
31089
12G2,5
31090
18G2,5
31091
24G2,5
31092
30G2,5
31093
36G2,5
31094
44G2,5
31095
48G2,5
31096
56G2,5

Outer
min. - max.
mm
31,0 - 34,5
14,6 - 16,9
20,6 - 23,4
20,3 - 22,9
24,2 - 27,4
27,7 - 31,1
27,9 - 31,3
31,2 - 34,8
31,8 - 35,4
35,9 - 39,7
17,5 - 19,8
23,8 - 26,7
23,4 - 26,2
28,2 - 31,1
31,1 - 34,4
31,3 - 34,7
36,2 - 40,2
37,2 - 41,0
41,6 - 46,0

Cop.
weight
kg/km
470,0
115,0
196,0
271,0
390,0
432,0
518,0
634,0
691,0
807,0
168,0
308,0
451,0
615,0
770,0
866,0
1057,0
1153,0
1344,0

Weight
approx.
kg/km
1420,0
320,0
620,0
650,0
930,0
1190,0
1240,0
1530,0
1610,0
2020,0
480,0
915,0
945,0
1330,0
1615,0
1710,0
2240,0
2410,0
2930,0

Tensile
strain
max. N
3450
2318
2540
2810
3080
3350
3620
3980
4160
4520
2520
2900
3350
3800
4250
4680
5250
5550
6150

AWG-No.
-

Dimensions and specifications may be changed without prior notice. (RG01)

G7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUSPREADER YSLT-J spreader cable for vertical basket enterprise




Technical data

Cable structure

Properties

Special cable lineto DIN VDE 0250


Temperature range
flexing -20 C to +60 C
fixed installation -20 C to +60 C
Max. operating temperature
at the conductor+90 C
max. Short circuit temperature
at the conductor +150 C
Nominal voltage
U0/U 300/500 V
max. Tensile load 2000 N
Minimum bending radius
15x cable
Current carrying capacity
to DIN VDE 0298 part 4

Bare copper, fine or extra fine wire


conductor to DIN VDE 0295 cl. 5 and 6, BS
6360 cl. 5 and 6, IEC 60228 cl. 5 and 6
Special EPR-core insulation
Black cores with continuous white
numbering to DIN VDE 0293
Green yellow earth-core
Cores laid-up in lay of length, stranding
with optimal length of twists around a
Kevlar element
Special polychloropren outer jacket
Jacket colour black (RAL 9005)

weather resistant
UV-resistant
high abrasion resistance


Note

G = with green-yellow earth core.


Delivery on request:
also as -K model, temperature range
-40 C to +80 C
further dimensions and special designs

Application
As Spreader cable with high mechanical stresses in vertical basket operation in dry, moist, wet environment andin open air. Please note that
at the installation the cable must be placedcounterwise and free of twist into the basket.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
40160
36G2,5
40161
42G2,5
40162
48G2,5
40163
54G2,5

Outer
min. - max.
mm
38,1 - 41,0
40,8 - 43,8
45,7 - 48,7
47,0 - 51,0

Cop.
weight
kg/km
864,0
1008,0
1152,0
1296,0

Weight
approx.
kg/km
2500,0
3000,0
3650,0
4100,0

Tensile
strain
max. N
2000
2000
2000
2000

AWG-No.
14
14
14
14


Part no. No.cores x
cross-sec.
mm
40164
36G3,3
40165
42G3,3
40166
48G3,3
40167
54G3,3

Outer
min. - max.
mm
42,4 - 45,5
46,6 - 49,6
52,0 - 55,0
56,6 - 60,0

Cop.
weight
kg/km
1140,0
1330,0
1521,0
1711,0

Weight
approx.
kg/km
3200,0
3750,0
4450,0
5000,0

Tensile
strain
max. N
2000
2000
2000
2000

AWG-No.
12
16
16
16

Dimensions and specifications may be changed without prior notice. (RG01)

G8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

(N)TSCGEWU extremely torsionally stiff




Technical data

Cable structure

Properties

Medium voltage power cable according to


VDE 0250 part 813
Temperature range
flexing -20 C to +60 C
fixed installation -20 C to +80 C
Nominal voltages
U0/U 3,6/6kV, 6/10 kV, 8,7/15kV,12/20 kV
Operating voltages, max
3,6/6 kV = 4,2/7,2 kV
6/10 kV = 6,9/12 kV
8,7/15 kV = 10,4/18 kV
12/20 kV = 13,9/24 kV
Test voltages
3,6/6 kV = 11 kV
6/10 kV = 17 kV
8,7/15 kV =24 kV
12/20 kV = 29 kV
Minimum bending radius
15x outer diameter

Tinned copper conductor, fine wire


stranded according to DIN VDE 0295 cl. 5,
BS 6360 cl. 5 and
IEC 60228 cl. 5
Inner semi-conducting layer
HEPR-insulation
Outer semi-conducting layer
Groundconductor with semi-conductive
layer
Cores concentrically stranded
Inner jacket, jacket colour red
Antitorsional protection
Outer sheath: chloroprene rubber,
compound 5GM3
Jacket colour, red 

maximum permissible speed 200 m/min is


allowed when operating drums in one
direction
extremly torsion resistant
resistant against oils and fats, athmosperic
exposure and UV-radiation


Note

Further dimensions and special designs on


request

Application
Reeling medium voltage supply train for use in high mechanical stresses, such as in in container cranesor large mobile equipment as well
as excavators in the mining industry for days, in dry, damp, wet areas and outdoors.


3,6/6kV
Part no. No.cores x
cross-sec.
mm
38533
3 x 25 + 3 x 10
38534
3 x 35 + 3 x 10
38535
3 x 50 + 3 x 10
38536
3 x 70 + 3 x 16
38537
3 x 95 + 3 x 16
38538
3 x 120 + 3 x 25

Outer
Permanent Tensile
min. - max. load
strain
mm
N
max. N
37,0 - 40,0
1500
2200
40,0 - 43,0
2000
3100
44,0 - 47,0
3000
4300
47,0 - 50,0
4100
5100
52,0 - 56,0
5600
7000
56,0 - 60,0
7100
8500

Cop.
weight
kg/km
1008,0
1292,0
1728,0
2477,0
3197,0
4176,0

Weight 
approx.
kg/km
2280,0
2750,0
3400,0
4100,0
5450,0
6650,0

8,7/15kV
Part no. No.cores x
cross-sec.
mm
38545
3 x 25 + 3 x 10
38546
3 x 35 + 3 x 10
38547
3 x 50 + 3 x 10
39040
3 x 70 + 3 x 16
39041
3 x 95 + 3 x 16
39042
3 x 120 + 3 x 25

Outer
Permanent Tensile
min. - max. load
strain
mm
N
max. N
43,0 - 46,0
1500
2200
46,0 - 48,0
2000
3100
49,0 - 52,0
3000
4300
53,0 - 57,0
4100
5100
58,0 - 62,0
5600
7000
63,0 - 67,0
7100
8500

Cop.
weight
kg/km
1008,0
1292,0
1728,0
2477,0
3197,0
4176,0

Weight 
approx.
kg/km
2750,0
3210,0
3950,0
5000,0
6150,0
7700,0

Outer
Permanent Tensile
min. - max. load
strain
mm
N
max. N
46,0 - 49,0
1500
2200
49,0 - 52,0
2000
3100
53,0 - 57,0
3000
4300
57,0 - 61,0
4100
5100
62,0 - 66,0
5600
7000
67,0 - 70,0
7100
8500

Cop.
weight
kg/km
1008,0
1292,0
1728,0
2477,0
3197,0
4176,0

Weight 
approx.
kg/km
3040,0
3510,0
4410,0
5420,0
6750,0
8050,0

6/10kV
Part no. No.cores x
cross-sec.
mm
38539
3 x 25 + 3 x 10
38540
3 x 35 + 3 x 10
38541
3 x 50 + 3 x 10
38542
3 x 70 + 3 x 16
38543
3 x 95 + 3 x 16
38544
3 x 120 + 3 x 25

12/20kV
Outer
Permanent Tensile
min. - max. load
strain
mm
N
max. N
39,0 - 42,0
1500
2200
42,0 - 45,0
2000
3100
45,0 - 48,0
3000
4300
50,0 - 54,0
4100
5100
54,0 - 58,0
5600
7000
58,0 - 62,0
7100
8500

Cop.
weight
kg/km
1008,0
1292,0
1728,0
2477,0
3197,0
4176,0

Weight 
approx.
kg/km
2400,0
2900,0
3450,0
4600,0
5770,0
6900,0

Part no. No.cores x


cross-sec.
mm
39043
3 x 25 + 3 x 10
39044
3 x 35 + 3 x 10
39045
3 x 50 + 3 x 10
39046
3 x 70 + 3 x 16
39047
3 x 95 + 3 x 16
39048
1 x 120 + 3 x 25

Dimensions and specifications may be changed without prior notice. (RQ03)

G9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Cable Accessories

The expansion of our cable program rounds


our wide product range out

Photo: Helukabel

As a signicant addition to the extensive catalogue of cables and


connectors, HELUKABEL has set up a Cable Accessories Program
according to the latest guidelines and standards.
This applies to the following themes:

Cable xing
Cable protective sleeving
Drag and guidance chains
Isolation and Heatshrink sleeving
Termination & Connecting sleeves
Bundling, binding and xing
Identication and Marking
Terminals & cable lugs
Tools
Circular Connectors

G 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Robotic Cables

H1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Robotic Cables
With over 30 years of experience with cables
and lines, we also have the right solutions for
the demands placed on the components to be
installed by the applications of the robot.
Our specialists work with you to select the correct
cables, wires, supplemental systems and also construct the pre-assembled cable protection system
to suit your particular application.

H2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description
ROBOFLEX recycle................................................................................................................................................................

ROBOFLEX 2001 / 2001-C,Robot cables, meter marking........................................................................................................................


ROBOFLEX 150,...151,...152,...153,PUR, flame retardant, halogen-free, for torsional stress, meter marking.......................................................

ROBOFLEX 156-flat,PUR, flame retardant, halogen-free, for torsional stress.......................................................................................................


ROBOFLEX sewer robot,trailing...........................................................................................................................................................

Page
H 4
H 6
H 7
H 9

H 10

H3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX recycle


Technical data

Approval:
UL/cUL approved, UL-Style 20233
Production
in accordance with VDE standards
Temperature range:
fixed installation -40 C to +105 C
flexible -30 C to +105 C
Nominal voltage:
300 V
Test voltage:
2000V
Minimum bending radius:
approx. 7.5 x cable diameter (for flexible
installation)
Traversing speed:
max. 3.3 m/s for 5 m of horizontal traverse
path length
Acceleration:
max. 5 m/s
Flexing and torsion cycles:
min. 10 million.
Torsional stress:
+/- 360 /m

Cable structure

Assembly (3-pin)
Bare copper litz wire
Core insulation TPE
Cores stranded in layers
-D-screen: screened version for robot
application
-C-screen: in drag chain systems
Sheath, special mix
weld splatter resistant, dull, low adhesion,
flame retardant and self-extinguishing
according (to DIN VDE 0472 part 804 test
method B, IEC 60332-1)
Sheath colour: see below



Properties
very good resistance to oil as per DIN EN
60811-2-1
good resistance to acids, alkalis and
solvents
not cross-linked
weld splatter resistant
recyclable
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Free of substances harmful to paint
adhesion Substances
very high mechanical load capacity
abrasion resistant
wear-resistant
Highly flexible
UV-resistant

Application
The cables with this new sheath material cover all requirements for very large mechanical stresses for abrasion, tear resistance, torsion,
flexing, flexibility and oil resistance. Using for automation technology, plant and machine construction, fixture construction for handling
devices, welding devices and welding tongs, assembly and handling devices, machining production, welding robots and tool machines, blast
furnaces and rolling mills.
The completely new feature of this cable is the weld splatter resistance without the otherwise usual and required cross-linking process.
Our newly developed non-cross-linked thermoplastic elastomer is fully recyclable.
In contrast to this, the usual, cross-linked, thermoplastic elastomers cannot be recycled and put a not insignificant stress on our environment.
This must be particularly interesting for customers who have an environment management system according to DIN EN ISO14001 and
thus place a great deal of importance on the use of recyclable materials.
A significantly longer service life than that of existing cables on the market, because it can be used in highly flexible applications, for
example on robots (torsion) and in drag chains (dynamic load).
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


ROBOFLEX recycle
Part no.

701889
701891
701890
701894
701892
701893
701897
701895
701896
702805
702803
702804
701900
701898
701899

Jacket colour
Black RAL9005
Yellow RAL 1021
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001

Cable structure
No.cores x
cross-sec.
mm
3x0,25
3x0,25
3x0,25
4x0,25
4x0,25
4x0,25
5x0,25
5x0,25
5x0,25
8x0,25
8x0,25
8x0,25
3x0,34
3x0,34
3x0,34

Core colours
brown, blue, black
brown, blue, black
brown, blue, black
brown, blue, black, white
brown, blue, black, white
brown, blue, black, white
brown, blue, black, white, grey
brown, blue, black, white, grey
brown, blue, black, white, grey
DIN 47100
DIN 47100
DIN 47100
brown, blue, black
brown, blue, black
brown, blue, black

High
flex **
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

Outer
Cop.
approx. mm weight
kg/km
4,4
7,2
4,4
7,2
4,4
7,2
4,7
9,6
4,7
9,6
4,7
9,6
4,8
12,0
4,8
12,0
4,8
12,0
6,0
19,2
6,0
19,2
6,0
19,2
4,9
9,8
4,9
9,8
4,9
9,8

Weight
approx.
kg/km
22,0
22,0
22,0
26,0
26,0
26,0
30,0
30,0
30,0
55,0
55,0
55,0
30,0
30,0
30,0

Continuation

H4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX recycle
ROBOFLEX recycle
Part no.

701903
701901
701902
701906
701904
701905
702808
702806
702807
701910
701908
701909
701913
701911
701912

Jacket colour
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001

Cable structure
No.cores x
cross-sec.
mm
4x0,34
4x0,34
4x0,34
5x0,34
5x0,34
5x0,34
8x0,34
8x0,34
8x0,34
5G0,5
5G0,5
5G0,5
5G0,75
5G0,75
5G0,75

Core colours
brown, blue, black, white
brown, blue, black, white
brown, blue, black, white
brown, blue, black, white, grey
brown, blue, black, white, grey
brown, blue, black, white, grey
DIN 47100
DIN 47100
DIN 47100
JZ, black with numbering + greenyellow
JZ, black with numbering + greenyellow
JZ, black with numbering + greenyellow
JZ, black with numbering + greenyellow
JZ, black with numbering + greenyellow
JZ, black with numbering + greenyellow

High
flex **
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

Outer
Cop.
approx. mm weight
kg/km
5,2
13,1
5,2
13,1
5,2
13,1
5,9
16,4
5,9
16,4
5,9
16,4
6,8
26,1
6,8
26,1
6,8
26,1
6,0
24,0
6,0
24,0
6,0
24,0
7,0
36,0
7,0
36,0
7,0
36,0

Weight
approx.
kg/km
43,0
43,0
43,0
54,0
54,0
54,0
78,0
78,0
78,0
65,0
65,0
65,0
80,0
80,0
80,0

Outer
Cop.
approx. mm weight
kg/km
5,0
17,0
5,0
17,0
5,0
17,0
5,2
19,4
5,2
19,4
5,2
19,4
5,3
22,5
5,3
22,5
5,3
22,5
6,8
34,1
6,8
34,1
6,8
34,1
5,2
19,6
5,2
19,6
5,2
19,6
5,4
23,7
5,4
23,7
5,4
23,7
5,8
28,7
5,8
28,7
5,8
28,7
7,3
58,0
7,3
58,0
7,3
58,0
7,0
52,0
7,0
52,0
7,6
70,0
7,6
70,0
7,6
70,0

Weight
approx.
kg/km
44,6
44,6
44,6
46,3
46,3
46,3
50,0
50,0
50,0
53,5
53,5
53,5
48,2
48,2
48,2
53,0
53,0
53,0
61,9
61,9
61,9
85,0
85,0
85,0
76,0
76,0
93,0
93,0
93,0

Outer
Cop.
approx. mm weight
kg/km
5,0
17,0
5,0
17,0
5,0
17,0
5,2
19,4
5,2
19,4
5,2
19,4
5,3
22,5
5,3
22,5
5,3
22,5
6,8
34,1
6,8
34,1
6,8
34,1
5,2
19,6
5,2
19,6
5,2
19,6
5,4
23,7
5,4
23,7
5,4
23,7
5,8
28,7
5,8
28,7
5,8
28,7
7,3
58,0
7,3
58,0
7,3
58,0
7,0
52,0
7,0
52,0
7,0
52,0
7,6
70,0
7,6
70,0
7,6
70,0

Weight
approx.
kg/km
44,6
44,6
44,6
46,3
46,3
46,3
50,0
50,0
50,0
53,5
53,5
53,5
48,2
48,2
48,2
53,0
53,0
53,0
61,9
61,9
61,9
85,0
85,0
85,0
76,0
76,0
76,0
93,0
93,0
93,0

ROBOFLEX recycle screened, D-screen


Part no.

703843
703845
703844
703848
703846
703847
703851
703849
703850
703869
703867
703868
703854
703852
703853
703857
703855
703856
703860
703858
703859
703872
703870
703871
703863
703861
703866
703864
703865

Jacket colour
Black RAL9005
Yellow RAL 1021
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Yellow RAL 1021
Black RAL9005
Grey RAL 7001

Cable structure
No.cores x
cross-sec.
mm
3x0,25
3x0,25
3x0,25
4x0,25
4x0,25
4x0,25
5x0,25
5x0,25
5x0,25
8x0,25
8x0,25
8x0,25
3x0,34
3x0,34
3x0,34
4x0,34
4x0,34
4x0,34
5x0,34
5x0,34
5x0,34
8x0,34
8x0,34
8x0,34
5G0,5
5G0,5
5G0,75
5G0,75
5G0,75

Core colours
brown, blue, black
brown, blue, black
brown, blue, black
brown, blue, black, white
brown, blue, black, white
brown, blue, black, white
brown, blue, black, white, grey
brown, blue, black, white, grey
brown, blue, black, white, grey
DIN 47100
DIN 47100
DIN 47100
brown, blue, black
brown, blue, black
brown, blue, black
brown, blue, black, white
brown, blue, black, white
brown, blue, black, white
brown, blue, black, white, grey
brown, blue, black, white, grey
brown, blue, black, white, grey
DIN 47100
DIN 47100
DIN 47100
JZ, black with numbering + greenyellow
JZ, black with numbering + greenyellow
JZ, black with numbering + greenyellow
JZ, black with numbering + greenyellow
JZ, black with numbering + greenyellow

High
flex **
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

ROBOFLEX recycle screened, C-screen


Part no.

703873
703875
703874
703878
703876
703877
703881
703879
703880
703899
703897
703898
703884
703882
703883
703887
703885
703886
703890
703888
703889
703902
703900
703901
703893
703891
703892
703896
703894
703895

Jacket colour
Black RAL9005
Yellow RAL 1021
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001
Yellow RAL 1021
Black RAL9005
Grey RAL 7001

Cable structure
No.cores x
cross-sec.
mm
3x0,25
3x0,25
3x0,25
4x0,25
4x0,25
4x0,25
5x0,25
5x0,25
5x0,25
8x0,25
8x0,25
8x0,25
3x0,34
3x0,34
3x0,34
4x0,34
4x0,34
4x0,34
5x0,34
5x0,34
5x0,34
8x0,34
8x0,34
8x0,34
5G0,5
5G0,5
5G0,5
5G0,75
5G0,75
5G0,75

Core colours
brown, blue, black
brown, blue, black
brown, blue, black
brown, blue, black, white
brown, blue, black, white
brown, blue, black, white
brown, blue, black, white, grey
brown, blue, black, white, grey
brown, blue, black, white, grey
DIN 47100
DIN 47100
DIN 47100
brown, blue, black
brown, blue, black
brown, blue, black
brown, blue, black, white
brown, blue, black, white
brown, blue, black, white
brown, blue, black, white, grey
brown, blue, black, white, grey
brown, blue, black, white, grey
DIN 47100
DIN 47100
DIN 47100
JZ, black with numbering + greenyellow
JZ, black with numbering + greenyellow
JZ, black with numbering + greenyellow
JZ, black with numbering + greenyellow
JZ, black with numbering + greenyellow
JZ, black with numbering + greenyellow

High
flex **
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

Dimensions and specifications may be changed without prior notice.

H5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX 2001 / 2001-C Robot cables, meter marking




Technical data

Cable structure

Properties

Special TPE-E/PUR adapted to


DINVDE0245, 0250, 0282
Temperature range
flexing -30 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage
up to 0,34 mm 350 V (operating peak
voltage)
above 0,5 mm U0/U 300/500 V
Test voltage
up to 0,34 mm 1,5 kV, 5 minutes
above 0,5 mm 3,0 kV, 5 minutes
Mutual capacitance
core/core approx. 100 nF/km
core/screen approx. 120 nF/km
Inductance approx.
0,69 mH/km
Minimum bending radius
7,5x cabel

Bare copper, stranded to DINVDE0295 and


IEC60228, fine or extra fine wires, cl.5 or
cl.6, BS6360 cl.5 or 6, up to 0,34mm
cl.5, above 0,5mm cl.6
Special core insulation, TPE
Cores coded up to 0,34mm according
DIN47100
above 0,5mm black cores with continuous
white numbering according to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special separating foil
Cable structure C-type, cu-screen of
helically wound, approx. 85-95% coverage
Outher sheath, special polyurethane
Colour black (RAL 9005)
with meter marking, change-over in 2011


High flexibility at low temperatures


High abrasion resistance
Loadable under torsion stress 360 /meter
Low adhesion
Resistant to
Microbes and rotting
Oxygene and ozone
Vibrations
UV-radiation
Oil and fats resistant
PUR-jacket flame retardant according to
DINVDE0482 part265-2-1/ EN50265-2-1/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)

Application
These special robotic control and signal cables specially designed for torsion and bending stresses in robots and connecting handling tools.
EMC = Electromagnetic compatibillity. To optimise the EMC features we recommend a large round contact of the copper braiding on both
ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


ROBOFLEX 2001
Part no.
25459
25439
25460
25461
25462
25440
25449
25463
25519
25464
25465
25466
25450
25467
25468
25469
25470
25471
25472
25473
25474
25475
25476
25477
25520
25529
25559
25509
25478
25479
25480
25481
25482
25483
25530
25510
25484
25485
25486
25487

No.cores x
cross-sec.
mm
7G0,25
12G0,25
25G0,25
2G0,34
3G0,34
7G0,34
12G0,34
12G0,5
16G0,5
18G0,5
25G0,5
4G0,75
7G0,75
12G0,75
14G0,75
2G1
3G1
4G1
7G1
12G1
18G1
25G1
34G1
41G1
3G1,5
4G1,5
5G1,5
8G1,5
12G1,5
18G1,5
25G1,5
3G2,5
4G2,5
3G4
4G4
4G6
3G10
3G16
3G25
3G35

Outer
Cop.
approx. mm weight
kg/km
5,8
16,8
7,6
28,8
10,6
60,0
4,0
6,6
4,0
9,8
5,7
22,8
8,3
39,2
10,4
57,8
11,6
76,8
12,7
86,4
14,2
120,0
6,0
28,8
7,9
50,4
11,5
84,4
12,8
100,8
5,5
19,2
6,0
29,0
6,3
38,4
8,5
67,2
12,5
115,2
15,4
172,8
17,4
240,0
21,3
326,4
23,2
393,6
6,9
43,2
7,9
57,6
8,6
72,0
11,1
115,2
15,5
172,8
19,3
259,2
21,8
360,0
8,4
72,0
9,1
96,0
10,3
116,0
11,2
153,6
14,1
230,4
15,6
288,0
18,2
460,8
22,9
720,0
26,5
1008,0

Weight
approx.
kg/km
48,0
71,0
143,0
28,0
34,0
51,0
69,0
90,0
277,0
121,0
256,0
63,0
96,0
171,0
200,0
48,0
60,0
78,0
131,0
216,0
306,0
432,0
569,0
694,0
94,0
107,0
121,0
292,0
356,0
445,0
636,0
136,0
170,0
227,0
261,0
341,0
518,0
722,0
1180,0
1600,0

AWG-No.
24
24
24
22
22
22
22
20
20
20
20
18
18
18
18
17
17
17
17
17
17
17
17
17
16
16
18
16
16
16
16
14
14
12
12
10
8
6
4
2

ROBOFLEX 2001-C
Part no.
25539
25488
25489
25490
25491
25492
25493
25494
25495
25496
25497
25498
25499
25500
25501
25502
705462
25503
25504
25505
25506
25507
25508

No.cores x
cross-sec.
mm
10G0,14
12G0,14
18G0,14
25G0,14
12G0,25
18G0,25
25G0,25
12G0,34
18G0,34
25G0,34
12G0,5
18G0,5
25G0,5
12G0,75
18G0,75
25G0,75
3G1
12G1
18G1
25G1
12G1,5
18G1,5
25G1,5

Outer
Cop.
approx. mm weight
kg/km
7,8
34,2
7,8
42,1
9,7
54,5
10,9
69,0
8,3
59,5
10,1
80,0
11,1
103,0
8,8
78,0
10,8
101,0
12,0
158,0
11,2
117,0
13,6
160,0
14,8
255,0
11,8
155,0
15,0
210,0
16,6
275,0
6,3
76,0
13,0
190,0
16,1
245,0
18,1
345,0
16,2
260,0
20,3
370,0
22,5
498,0

Weight
approx.
kg/km
62,0
95,0
120,0
158,0
126,0
164,0
215,0
160,0
210,0
305,0
175,0
231,0
347,0
220,0
305,0
415,0
90,0
265,0
390,0
540,0
345,0
485,0
710,0

AWG-No.
26
26
26
26
24
24
24
22
22
22
20
20
20
18
18
18
22
17
17
17
16
16
16

Dimensions and specifications may be changed without prior notice. (RH01)

H6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX 150,...151,...152,...153 PUR, flame retardant,


halogen-free, for torsional stress, meter marking


Technical data

Cable structure

Properties

Special TPE-E/PUR robot cable


Based on DINVDE0245, 0250, 0281, 0282
Temperature range
flexing -40 C to +80 C
Nominal voltage
up to 0,34 mm 350 V
0.5 mm and greater U0/U 300/500 V
Test voltage
up to 0,34 mm 1500 V
0.5 mm and greater 3000 V
Insulation resistance
min. 20 MOhm x km
Max. torsion angle
360 /metre
Mutual capacitance
core/core approx. 100 nF/km
core/screen approx. 120 nF/km
Minimum bending radius
approx. 15x cable

Special bare copper, extra-fine wire acc. to


DINVDE0295 cl.6 + IEC60228 cl.6
TPE-E core insulation
Black cores continuous white numbering
according to DINVDE0293 + gnye
Special optimised stranding
High-grade slide wrapping
with meter marking, change-over in 2011
Tinned copper twist screen
PUR outer sheath
Sheath colour: grey (RAL 7001) or black
Part. nos. 77261-77263, 76158, 70561,
77267, 77268, 76165, 76166, 77424
Core colours DIN 47100
Part nos. 71820, 74658, 77264, 75253,
76167
Construction as above, but 0,5 (1,5) mm
cores screened with aluminium-coated
polyester foil
Part no. 72214
Construction as above, but 0,5 mm pair
screened with tinned twist screen
Part nos. 77265, 77266, 77269, 77270
Construction as above, but 1,0 mm pair
only, screened with tinned twist screen
Part no. 77469
Construction as above, but
6 cores, 1,5 mm, screened with tinned
twist screen
4 pairs, 0,25 mm, screened with tinned
twist screen
Sheath colour: orange (RAL 2003)
with meter marking, change-over in 2011


PUR outer sheath, low adhesion, abrasion


resistant, halogen-free, resistant to UV, oil,
hydrolysis and microbial attack
PUR sheath, self-extinguishing and flame
retardant according to VDE0482-332-1-2,
DIN EN60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The smooth, high-grade core insulation,
together with special stranding
configuration and slide wrapping ensure
long service life under combined bending
and torsional stresses

Application
These cables are specially designed for combined torsional and bending stresses. They are employed both for power supply and for the
transmission of control and monitoring signals. Roboflex cables are used in assembly and welding robots, in handling and automation
centres, in transport and conveyor equipment, and on turntables and swivel tables. In other words, anywhere where there is no defined
cable routing with only alternating bending cycles on a single plane such as in drag chains.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Continuation

H7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX 150,...151,...152,...153 PUR, flame retardant,


halogen-free, for torsional stress, meter marking
ROBOFLEX 150 (screened), Sheath colour grey
Part no. No.cores x
cross-sec.
mm
77261
( 12 x 0,25)
77266
( 23 x 1 + 2 x 1,0)
71789
( 4 x 1,5)
75251
( 4 x 2,5)
75252
( 4 x 4)
76157
( 4 x 6)
77262
( 3 x 2 x 0,14)
77263
( 4 x 2 x 0,14)
76158
( 5 x 2 x 0,34)
70561
( 8 x 2 x 0,34)
71820
( 4 x 1,5 + (2 x 0,62))
74658
( 4 x 1,5 + (2 x 0,5))
77264
( 4 x 1,5 + (2 x 1,0))
75253
( 4 x 2,5 + (2 x 0,5))
72214
( 4 x 4 + (2 x 0,5))
76159
( 4 x 4 + (2 x 1,0))
76160
( 4 x 6 + (2 x 1,0))
77265
( 16 x 1 + (2 x 1,0))

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
8,3
59,5
126,0
17,4
262,0
473,0
8,9
81,7
150,0
11,2
134,0
280,0
13,1
200,0
400,0
15,4
286,0
550,0
5,8
17,0
43,0
6,9
37,0
75,0
9,2
65,0
116,0
10,2
90,0
150,0
10,5
106,8
195,0
10,7
95,0
180,0
11,1
128,0
220,0
12,5
180,0
270,0
13,5
260,0
340,0
14,0
237,0
350,0
16,0
341,0
500,0
16,7
197,0
380,0

AWG-No.

ROBOFLEX 152 (screened), Sheath colour black


Part no. No.cores x
cross-sec.
mm
76161
( 4 x 1,5)
76162
( 4 x 2,5)
76163
( 4 x 4)
76164
( 4 x 6)
77267
( 3 x 2 x 0,14)
77268
( 4 x 2 x 0,14)
77424
( 3 x 2 x 0,25)
76165
( 5 x 2 x 0,34)
76166
( 8 x 2 x 0,34)
75415
( 4 x 1,5 + (2 x 0,5))
75416
( 4 x 2,5 + (2 x 0,5))
75940
( 4 x 2,5 + (2 x 1,0))
75167
( 4 x 4 + (2 x 0,5))
75417
( 4 x 4 + (2 x 1,0))
75418
( 4 x 6 + (2 x 1,0))
77269
( 16 x 1 + (2 x 1,0))
77270
( 23 x 1 + (2 x 1,0))
77469
( 5 x 2,5 + (6 x 1,5) + 4 x (2 x
0,25))

24
16
14
12
10
26
26
22
22
16
16
16
14
12
12
10
17

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
8,9
81,7
150,0
11,2
164,0
280,0
13,1
222,0
400,0
15,4
305,0
550,0
5,8
23,0
43,0
6,9
26,6
55,0
7,3
32,0
65,0
9,2
65,0
116,0
10,2
90,0
150,0
10,7
95,0
170,0
11,8
115,0
220,0
12,3
147,0
250,0
13,5
260,0
340,0
14,0
237,0
350,0
16,0
316,0
500,0
16,7
176,0
380,0
17,4
262,0
473,0
16,7
320,0
460,0

AWG-No.
16
14
12
10
26
26
24
22
22
16
14
14
12
12
10
17
17
14

ROBOFLEX 151, Sheath colour grey


Part no.
70116
76168
76169
76170
76171

No.cores x
cross-sec.
mm
12G0,5
4G1,5
4G2,5
4G4
4G6

Outer
Cop.
approx. mm weight
kg/km
8,3
57,6
8,5
57,6
10,8
96,0
12,7
153,6
15,0
230,4

Weight
approx.
kg/km
131,0
106,0
196,0
283,0
432,0

AWG-No.
20
16
14
12
10

ROBOFLEX 153, Sheath colour black


Part no.
76172
76174
76175

No.cores x
cross-sec.
mm
4G1,5
4G4
4G6

Outer
Cop.
approx. mm weight
kg/km
8,5
57,6
12,7
153,6
15,0
230,4

Weight
approx.
kg/km
106,0
283,0
432,0

AWG-No.
16
12
10

Dimensions and specifications may be changed without prior notice.

H8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX 156-flat PUR, flame retardant, halogen-free, for torsional stress




Technical data

Cable structure

Properties

Special TPE-E/PUR robot cable adapted to


DINVDE0245, 0250, 0281, 0282
Temperature range
flexing -40 C to +80 C
Nominal voltage
up to 0,34 mm 350 V
0,5 mm an greater 300/500 V
Test voltage
up to 0,5 mm 1500 V
0,5 mm and greater 3000 V
Insulation resistance
min. 20 MOhm x km
Max. torsion angle
360 /metre
Mutual capacitance (signal cores)
core/core approx. 100 nF/km
core/screen approx. 120 nF/km
Minimum bending radius
approx. 15x cable

Tinned copper conductor, 19x0,32/1,5


mm,
19x0,102/0,15 mm
4 stranded cores 1,5 mm
Screen of tinned copper braid
TPE-E sheath, black
12 cores 0,15 mm stranded together
Screen of tinned copper braid
TPE-E sheath, black
6 cores 0,15 mm stranded in paired
Screen of tinned copper braid
TPE-E sheath, black
10 stranded cores 0,15 mm
Screen of tinned copper braid
Black TPE-E sheath
Over the 4 elements in parallel PUR sheath
Outer sheath colour black


The smooth, very high quality core


insulation, together with the special
threading lay and the sliding wrapper
ensure a long service life under combined
bending and torsional stress
PUR sheath, matt, low adhesion, flame
retardant

Application
These cables are specially designed for combined torsional and bending stresses. They are employed both for power supply and for the
transmission of control and monitoring signals.
Roboflex cables are used in assembly and welding robots, in handling and automation centres, in transport and conveyor equipment, and
on turntables and swivel tables. In other words, anywhere where there is no defined cable routing with only alternating bending cycles in
one plane, such as in energy supply chains, for example.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.cores x


Outer Cop.
Weight
cross-sec.
approx. weight approx.
mm
mm
kg/km kg/km
78499
( 4 x 2 + 12 x 0,15 + 3 x 2 x 0,15 7,2
128,6
200,0
+ 10 x 0,15)

AWG-No.
16

Dimensions and specifications may be changed without prior notice. (RH01)

H9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX sewer robot trailing




Technical data

Cable structure

Properties

Temperature range
flexing -40 C to +80 C
Nominal voltage
300/500 V
Test voltage 3000 V
Insulation resistance
min. 20 MOhm x km

Part No. 74540


Bare copper, ultra-fine wire conductors
acc. to DINVDE0295 cl. 6 and/or IEC60228
cl. 6
Core insulation TPE-E, black with
numbering
3 COAX 187/U stranded
Cores and COAX elements and PVC sleeves,
special stranded
PUR outer sheath with embedded
high-tensile and high-torsion resistant
Kevlar braid
Sheath colour orange (RAL 2003)
Part No. 70581
Bare copper, ultra-fine wire conductors
acc. to DINVDE0295 cl.6 or IEC60228 cl.6
PVC core insulation, colour code DIN47100
Cores stranded with COAX
Overall screening with tinned copper braid,
coverage approx. 85%
Special PVC sheath
Sheath colour grey (RAL 7001)
Part No. 76397 (trailing cable for video
cameras)
Tinned copper conductor, fine wire
stranded
Core insulation of cell polypropylene
Screen of aluminium-coated polyester foil
and tinned copper braiding
PUR outer jacket
Sheath colour blue (RAL 5015)

To enhance reliability and tensile strength,


a high-tensile and high-torsion resistant
Kevlar braid is incorporated into the
extremely robust PUR sheath
Part No. 74540+76397
PUR sheath: low adhesion, extremely
abrasion resistant, halogen-free, resistant
to UV, oil, hydrolysis and microbial attack
Part No. 70581
Special PVC sheath, largely oil resistant,
self-extinguishing and flame retardant, test
methodB acc. to DINVDE0472 part804
and IEC60332-1, chemical resistant (see
table Technical Information)

Application
These cables are designed for use with autonomous sewer robots.
These robots are used to inspect municipal sewer networks and if necessary to locate leaks or blockages. Some of these robots are even
able to seal such leaks after detecting them. Besides cores for power supply, they also contain data cables, hoses for various drives, and
coaxial cables for the video camera mounted on the robot.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Dimensions and specifications may be changed without prior notice. (RH01)

H 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Water resistant Cables

I1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Water resistant Cables


For constant use in water for general use, waste
water and drinking water*, up to a depth of
immersion of 500 m to connect electrical operating
materials such as submersible motor pumps, for
medium mechanical stresses.
*on request

I2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description
Tauchflex-R,750V, blue, submersible-pump cable.........................................................................................................................................
Tauchflex-FL,750 V, blue, submersible pump cable.......................................................................................................................................
H07 RN8-F,waterproof rubber-sheathed cable, harmonized type..................................................................................................................

Page
I 4
I 5
I 6

I3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Tauchflex-R 750V, blue, submersible-pump cable




Technical data

Cable structure

Properties

Special cables corresponding to


DINVDE0250 and 0282 part810
Temperature range
-40 C to +80 C (max. temperature for the
outer surface)
Permissible operating temperature
at conductor +90C
Nominal voltage U0/U 450/750 V
Operating voltage for alternating and
three-phase currents U0/U 413/825 V,
for direct currents U0/U 619/1238 V
Current rating to DIN57100part 523/
VDE0100 part523
Test voltage 15 min 2,5 kV
Max. permitted tensile stress
per mm conductor 15 N

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Foil as separator
EPR core insulation, compound type 3GI3
to DINVDE0207 part20
Colour code according to DINVDE0293
Cores standed in layers with optimal
lay-length
EPR outer sheath, blue, compound type
5GM3 adapted to DINVDE0207 part21
Minimum bending radius
flexing
up to 8 mm cond. min. 3x cond.
above 8 mm to 12 mm cond.
min. 4x cond.
above 12 mm cond. min. 5x cond.
fixed installation
up to 12 mm cond. min. 3x cond.
above 12 mm cond. min. 4x cond.
Temperature limit
in water: max. +40 C, max. +60 C
with limited duration of life
in air:
flexible -50 C to +80 C
stationary -30 C to +80 C

Good insulation properties when


submerged in water
Minimal weight gain under water
The mechanical stability of the insulation
materials remains constant even when
submerged
Not suitable for drinking water.
Cables for use in drinking water with
BAM-certificate on request (BAM
Bundesanstalt fr Materialprfung/Federal
Institute for Materials Testing).
Installation adaptability for machinery
material of protection class II
As rotor-connection cable for motors up
to 1000 V with protected fixed installation
in tubes.


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Please note: halogen-free types available
on request.

Application
Tauchflex-R is a special cable for use as a connecting and control cable for submersible motor pumps, underwater floodlights, floating switch
and has proven its worth for constant use in waste water or water for general use up to the depth of immersion of 500 m (50 bar) and
under temperatures of up to 70 C.
Tauchflex-R can also be installed for use in dry, damp and humid areas as well as in the open air.
Not suitable for the installation in hazardous areas.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
37100
37101
37102
37103
37104
37105
37106
37107
37108
37109
37110
37111
37112
37113
37114
37115
37116
37117
37118
37119
37120
37121
37122
37123
37124
37125
37126

No.cores x
cross-sec.
mm
1x1,5
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
2x1,5
2x2,5
2x4
2x6
2x10
2x16
2x25
3x1,5
3x2,5
3x4
3x6

Outer
approx. mm
7,2
8,0
7,2
7,9
9,5
11,5
13,5
15,0
17,5
20,0
22,5
24,0
25,2
27,6
30,6
33,5
8,5
10,2
11,8
13,1
17,7
20,2
24,3
9,5
11,0
13,0
14,5

Cop.
weight
kg/km
14,0
24,0
38,0
58,0
96,0
154,0
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0
1776,0
2304,0
2880,0
29,0
48,0
77,0
115,0
192,0
307,0
480,0
43,0
72,0
115,0
173,0

Weight
approx.
kg/km
54,0
76,0
105,0
135,0
200,0
290,0
400,0
560,0
730,0
1000,0
1250,0
1650,0
2000,0
2460,0
3050,0
3700,0
130,0
190,0
260,0
350,0
550,0
900,0
1300,0
150,0
205,0
330,0
470,0

AWG-No.
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
16
14
12
10
8
6
4
16
14
12
10


Part no.
37127
37128
37129
37130
37131
37132
37133
37134
37135
37136
37137
37138
37139
37140
37141
37142
37143
37144
37145
37146
37147
37148
37149
37150
37151
37152
37153

No.cores x
cross-sec.
mm
3x10
3x16
3x25
3x35
3x50
3x70
3x95
3x120
4G1,5
4G2,5
4G4
4G6
4G10
4G16
4G25
4G35
4G50
4G70
4G95
4G120
5G1,5
5G2,5
5G4
5G6
5G10
5G16
5G25

Outer
approx. mm
19,0
23,5
28,5
32,0
37,0
42,0
43,3
59,0
13,4
15,4
14,0
15,5
21,0
25,5
31,0
35,0
41,0
46,5
51,6
56,1
11,2
13,3
15,6
17,5
22,9
26,4
32,0

Cop.
weight
kg/km
288,0
461,0
720,0
1008,0
1440,0
2016,0
2736,0
3456,0
58,0
96,0
154,0
230,0
384,0
614,0
960,0
1344,0
1920,0
2688,0
3648,0
4608,0
72,0
120,0
192,0
288,0
480,0
768,0
1200,0

Weight
approx.
kg/km
750,0
1110,0
1450,0
2150,0
2800,0
3750,0
4590,0
5400,0
190,0
270,0
380,0
520,0
955,0
1400,0
1950,0
2650,0
3600,0
4890,0
6180,0
7200,0
225,0
335,0
470,0
645,0
1150,0
1690,0
2400,0

AWG-No.
8
6
4
2
1
2/0
3/0
4/0
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
16
14
12
10
8
6
4

Dimensions and specifications may be changed without prior notice. (RI01)

I4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Tauchflex-FL 750 V, blue, submersible pump cable




Technical data

Cable structure

Properties

Special cables corresponding to


DINVDE0250 and 0282 part810
Temperature range
-40 C to +80 C (max. temperature for the
outer surface)
Permissible operating temperature
at conductor +90C
Nominal voltage U0/U 450/750 V
Operating voltage for alternating and
three-phase currents U0/U 413/825 V,
for direct currents U0/U 619/1238 V
Current rating to DIN57100part 523/
VDE0100 part523
Test voltage 15 min 2,5 kV
Max. permitted tensile stress
per mm conductor 15 N
Minimum bending radius
flexing
up to 8 mm cond. min. 3x cond.
above 8 mm to 12 mm cond.
min. 4x cond.
above 12 mm cond. min. 5x cond.
fixed installation
up to 12 mm cond. min. 3x cond.
above 12 mm cond. min. 4x cond.
Temperature limit
in water: max. +40 C, max. +60 C
with limited duration of life
in air:
flexible -50 C to +80 C
stationary -30 C to +80 C

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Foil as separator
EPR core insulation, compound type 3GI3
to DINVDE0207 part20
Colour code according to DINVDE0293
Cores laying parallel
EPR outer sheath, blue, compound type
5GM3 adapted to DINVDE0207 part21

Good insulation properties when


submerged in water
Minimal weight gain under water
The mechanical stability of the insulation
materials remains constant even when
submerged
Not suitable for drinking water.
Cables for use in drinking water with
BAM-certificate on request (BAM
Bundesanstalt fr Materialprfung/Federal
Institute for Materials Testing).
Installation adaptability for machinery
material of protection class II
As rotor-connection cable for motors up
to 1000 V with protected fixed installation
in tubes.


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Please note: halogen-free types available
on request.

Application
Tauchflex-FL is a special cable for use as a connecting and control cable for submersible motor pumps, underwater floodlights, floating
switch and has proven its worth for constant use in waste water or water for general use up to the depth of immersion of 500 m (50 bar)
and under temperatures of up to 70 C.
Tauchflex-FL can also be installed for use in dry, damp and humid areas as well as in the open air.
Not suitable for the installation in hazardous areas.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
37155
37156
37157
37158
37159
37160
37161
37162
37163
37164
37165
37166

No.cores x
cross-sec.
mm
3x1,5
3x2,5
3x4
3x6
3x10
3x16
3x25
3x35
3x50
3x70
3x95
3x120

Outer
min. - max.
mm
7,0 - 13,0
8,0 - 16,0
9,0 - 19,0
10,0 - 23,0
12,0 - 28,0
14,0 - 31,0
17,0 - 37,0
17,0 - 38,0
20,0 - 45,0
22,0 - 52,0
25,0 - 58,0
27,0 - 64,0

Cop.
weight
kg/km
43,0
72,0
115,0
173,0
288,0
461,0
720,0
1008,0
1440,0
2016,0
2736,0
3456,0

Weight
approx.
kg/km
125,0
185,0
290,0
400,0
615,0
890,0
1155,0
1540,0
2190,0
2890,0
3800,0
4700,0

AWG-No.
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0


Part no.
37167
37168
37169
37170
37171
37172
37173
37174
37175

No.cores x
cross-sec.
mm
4G1,5
4G2,5
4G4
4G6
4G10
4G16
4G25
4G35
4G50

Outer
min. - max.
mm
7,0 - 17,0
8,0 - 20,0
9,0 - 24,0
10,0 - 26,0
11,0 - 31,0
13,0 - 36,0
15,0 - 45,0
17,0 - 48,0
20,0 - 59,0

Cop.
weight
kg/km
58,0
96,0
154,0
230,0
384,0
614,0
960,0
1344,0
1920,0

Weight
approx.
kg/km
160,0
245,0
330,0
450,0
850,0
1200,0
1590,0
2085,0
2890,0

AWG-No.
16
14
12
10
8
6
4
2
1

Dimensions and specifications may be changed without prior notice. (RI01)

I5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H07 RN8-F waterproof rubber-sheathed cable, harmonized type




Technical data

Cable structure

Water resistant heavy hose pipeto


DINVDE0282 part16, HD22.16 S1
Temperature range
flexing -25 C
fixed installation -40 C
in water max. +40 C
Permissible operating temperature
at conductor +60 C
Nominal voltage U0/U 450/750 V
in case of protected and fixed installation
U0/U 600/1000 V
Test voltage 2500 V
Permanent tensile load
max. 15 N/mm
Minimum bending radius
flexing 6 x cable
fixed installation 4x cable

Copper conductor fine wire stranded, bare


to DINVDE0295 cl.5, BS6360 cl.5,
IEC60228 cl.5 and HD383
Rubber core insulation EI4 to DINVDE0282
part1
Core identification to DINVDE0293-308
and HD186
Core colours
up to 5 cores one-coloured
6 and more cores, black with numbering
3 and above, with green-yellow earth core
2 cores without green-yellow earth core
Cores stranded in layers with optimal
lay-length
Special polychoroprene rubber outer jacket
Outer jacket black

Properties

Resistant to
Ozone
Weather
Oil resistant
Test according to EN 60811-2-1
Test of behaviour compared to
environmental influences
Test according to DINVDE0482
part265-2-1/ EN50265-2-1/ IEC60332-1
(equivalent DINVDE0472 part804 test
methodB)
The core identification of a single core
jacketed, of an insulated wire is black.
For application as a protective core, the
ends are to be identified with green-yellow
and the middle conductor with light blue


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.


Application
Water resistant heavy hose pipe for connection of submersible pumps and similar applications, at a recommended water depth to 10 m
and a maximum water temperature of +40 C. Can be used in dry, damp and wet areas as well as in open air.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
37287
37288
37289
37290
37291
37292
37293
37294
37295
37296
37297
37298
37299
37300
37301
37302
37303
37304
37305
37306
37307
37308
37309
37310
37311
37312
37313
37314

No.cores x
cross-sec.
mm
1x1,5
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
2x1
2x1,5
2x2,5
2x4
2x6
2x10
2x16
2x25
3G1
3G1,5

Outer
min. - max.
mm
5,7 - 7,1
6,3 - 7,9
7,2 - 9,0
7,9 - 9,8
9,5 - 11,9
10,8 - 13,4
12,7 - 15,8
14,3 - 17,9
16,5 - 20,6
18,6 - 23,3
20,8 - 26,0
22,8 - 28,6
25,2 - 31,4
27,6 - 34,4
30,6 - 38,3
33,5 - 41,9
37,4 - 46,8
41,3 - 52,0
7,7 - 10,0
8,5 - 11,0
10,2 - 13,1
11,8 - 15,1
13,1 - 16,8
17,7 - 22,6
20,2 - 25,7
24,3 - 30,7
8,3 - 10,7
9,2 - 11,9

Cop.
weight
kg/km
14,4
24,0
38,0
58,0
96,0
154,0
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0
1776,0
2304,0
2880,0
3840,0
4800,0
19,0
29,0
48,0
77,0
115,0
192,0
307,0
480,0
29,0
43,0

Weight
approx.
kg/km
58,0
71,0
100,0
130,0
230,0
290,0
420,0
530,0
750,0
960,0
1250,0
1560,0
1900,0
2300,0
2950,0
3600,0
4600,0
6000,0
98,0
135,0
193,0
280,0
330,0
586,0
810,0
1160,0
130,0
165,0

AWG-No.
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
17
16
14
12
10
8
6
4
17
16


Part no.
37315
37316
37317
37318
37319
37320
37321
37322
37323
37324
37325
37326
37327
37328
37329
37330
37331
37332

No.cores x
cross-sec.
mm
3G2,5
3G4
3G6
3G10
3G16
3G25
3G35
3G50
3G70
3G95
3G120
3G150
3G185
3G240
3G300
4G1
4G1,5
4G2,5

Outer
min. - max.
mm
10,9 - 14,0
12,7 - 16,2
14,1 - 18,0
19,1 - 24,2
21,8 - 27,6
26,1 - 33,0
29,3 - 37,1
34,1 - 42,9
38,4 - 48,3
43,3 - 54,0
47,4 - 60,0
52,0 - 66,0
57,0 - 72,0
65,0 - 82,0
72,0 - 90,0
9,2 - 11,9
10,2 - 13,1
12,1 - 15,5

Cop.
weight
kg/km
72,0
115,0
173,0
288,0
461,0
720,0
1008,0
1440,0
2016,0
2736,0
3456,0
4320,0
5328,0
6192,0
8640,0
38,0
58,0
96,0

Weight
approx.
kg/km
235,0
320,0
420,0
810,0
1050,0
1250,0
1900,0
2600,0
3400,0
4450,0
5180,0
6500,0
7860,0
10224,0
12620,0
150,0
200,0
290,0

AWG-No.
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
17
16
14

Continuation

I6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H07 RN8-F waterproof rubber-sheathed cable, harmonized type




Part no.
37333
37334
37335
37336
37337
37338
37339
37340
37341
37342
37343
37344
37345
37346
37354
37347
37348
37349

No.cores x
cross-sec.
mm
4G4
4G6
4G10
4G16
4G25
4G35
4G50
4G70
4G95
4G120
4G150
4G185
4G240
4G300
5G1
5G1,5
5G2,5
5G4

Outer
min. - max.
mm
14,0 - 17,9
15,7 - 20,0
20,9 - 26,5
23,8 - 30,1
28,9 - 36,6
32,5 - 41,1
37,7 - 47,5
42,7 - 54,0
48,4 - 61,0
53,0 - 66,0
58,0 - 73,0
64,0 - 80,0
72,0 - 91,0
80,0 - 101,0
10,2 - 13,1
11,2 - 14,4
13,3 - 17,0
15,6 - 19,9

Cop.
weight
kg/km
154,0
230,0
384,0
614,0
960,0
1344,0
1920,0
2688,0
3648,0
4608,0
5760,0
7104,0
9216,0
11520,0
48,0
72,0
120,0
192,0

Weight
approx.
kg/km
395,0
540,0
950,0
1260,0
1860,0
2380,0
3190,0
4260,0
5600,0
6830,0
8320,0
9800,0
12100,0
15200,0
175,0
240,0
345,0
485,0

AWG-No.
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
4
16
14
12


Part no.
37350
37351
37352
37353
37355
37356
37357
37358

No.cores x
cross-sec.
mm
5G6
5G10
5G16
5G25
6G1,5
6G2,5
12G1,5
12G2,5

Outer
min. - max.
mm
17,5 - 22,2
22,9 - 29,1
26,4 - 33,3
32,0 - 40,4
13,4 - 17,2
15,7 - 20,0
17,6 - 22,4
20,6 - 26,2

Cop.
weight
kg/km
288,0
480,0
768,0
1200,0
87,0
144,0
173,0
288,0

Weight
approx.
kg/km
650,0
1200,0
1550,0
2250,0
171,0
279,0
340,0
571,0

AWG-No.
10
8
6
4
4
4
4
4

Dimensions and specifications may be changed without prior notice. (RI01)

Cable Glands
Cable glands for standard applications
Plastic Glands
Cable Glands of Brass
Accessories
Cable glands for special application conditions
for electromagnetic compatibility EMC
for rugged applications and special chemical resistance
for high temperature use
for explosive areas
for special mounting conditions
for special pressure conditions

You can nd cable glands in our catalogue Cable Accessories.

I7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Productinformations
With product-yers HELUKABEL is giving informations forward to customers
and business-partners about news, offers or just worth knowing around Data,
Network & Bus Technology.

(:

1
:

EO

OD

DL

$Y

VW

[

H
H

:1



*




+(/8723+7063OXV
(5 $
:
XEH 7KHFDEO
W
9
2
G

H
G
HJODQGZLWKWKH
W
XJD
3 FRQ
[

1(

:


FN

(:

1(

:

(
1

1(:

1(:


1(:

[

D
'DW JH
LFDO
Q

&

SWR
UD
&X
WXUH Q &
R
HUD
OODWL
LXV
R
PS
7H GLQVWD &XSW JUDG 
U
LQ

[H

IL
HQG [RXWH
QJ
IOH[L LPXPE WLRQ 
OOD
LQ
U
0 GLQVWD [RXWH

IL[H J
OH
Q
XUH
FDE
IOH[L
XFW
ZHU
VWU WXQGSR
OH
RLO 
E
HU
FHI
&D

PHQ
HOH LWKILOO LWKIOHH 
;
0
' QGHGZ SLQJZ VRIW
VWUD ZUDS 39&
DWK
RUH
P
& WHUVKH 
X
P
/

$
2


5
S
EODFN UDS
P
XWH
P
2
HQW S[ NLQ3(
/
6
S
OHP
6L
HULDO
;H SSHUD )RDP H
HU
9$$L
0DW
'0
VVWHHO
FR ODWLRQ ZKLW [WLOHILOO
UH
FDWLRQ
D

H
6WDLQOHV
RLO 
KW
% UHLQVX XUUHG

FODVVLIL
FHI
ZLW
R
HFWLRQ
ELQDWLRQ
& UHFROR UDQGHG J IOHH RSSHU
QFRP
3URW
F
R
.L
,3
& RUHVVW UDSSLQ WLQQHG RQJ 

,3
&OLFN
P
I
Z
8FRQG
F DQGHG HHQR  D PP 
(/
+
H
FU WLF
ZLWK
 
6WU LG
UHUDQJ
EOH
HGV
HV VWDSUR[ [
GVSDFJHDS UILOOHU IW
SHUDWX
%UD
O\IOHLQ[LFRQILQH
H
&
UD
7HP
UH
+LJKS
&VWR
FRYH GFRSSLVWD
9Q
XSWR
UHVD
ODFHG
P
&
WK 3WHPSHUDWX
QH UHV
&DQEH
HDHV
WLQUH
P KP
LQ
VKQF

S
HUUH
SHUDJKWX
Q'LQIIH
$/ DS 2
,
W
HP

5
W
+LJK&OLTXLGWL QGLWLREODQVFNHUVKHDWKSHGDQFH
G

WLFFR ,QQ VLFLP Q
8SWR
JODQ
P
WXEH
DOLQVWD
LQDWLR
P
QWULF
W G&OLFN
XQFULWLF
W
[
,LI
HQRQ
P8F
 OYHQ
ODVV
+(/

HQR
GV
 LRQF DWLRQZHLWK
UHOH HUDSS 39& VDQ
JUH LOO
QJFW
 VHURZQHU
DEOLWH.LQFRPELQ 3RZ UHFRSS JWLUH
3FUR
WK HZ XP
OD REQVHOXDRHIIELUH
D RQLOVX
XW,3

,3H[
R

%
OF
K

L
FD
U
RUHOYHQWR,Q
GWD 
 ZLW
ORXU
WDQWQGWR
&VR
 IR
QGH
KRZ
 HVLV
\ WR
VD &
OHU
RUHF RNH DOVWUD FN5$/
JKWV
DQGVP
OD
WULFLW
+ULGLJ FKDEO\WRRLOJUHDVH
J OL
JDVHV\HOORZ VRSWLP 9&E PP &OLFN
HOHF
HLRQRIWR[LF
K\E5HVLVWDQW7KLVV
WDNLQ
QG
LQ3JDLWKSS+(/8FRQG
FRUHLH
HDWK
(5
OV D
V
UHDWK
3
LUHRHP
KHUVKOG
Z
EHQ
WK
JQD
Z
LRQ
&ODVV%LQDFFRUGDQFHZLWK(1
32:
Q
D E
D
DW
Q
VL
O\
Q
H
0


W
O
(
ELQ
,
H
S
RYHUWKHHQWLUHFODPSUDQJH
;
,
FRHPUVK
HF
FWLR
VXS
QWUR
PDN
Q
'0
SHUI DO (0 KLHOGLQJLQ
VWUX
,Q
ZHU
' 
J FR
 WR
FRQ
JLVSWLPKP,(
03V
LEOH
HSR

281
WRU *
YLGLQ
LGLQ 2 WLP
DO(0
RWLFH
2
SRVV
SUR
/86
GWK
EUD
GXF
ULRUQ
 ODQG G
J\
 +(
SHU
V2S
&RQ 
QRW
HDQ
OR
H
S
RXWS 3URWHFWLRQFODVVLILFDWLRQ


Q
LU
J
UG
R
K
R

LV
LWK
EH
[
D
D
7
Z
Q
,3DWKLJ
WX WLRQ

R
KSUHVVXUHRIXSWREDUDQGIRUK
O
GZ

,W
GF
[
WHFK
LJK
DGV
OD
 EHFKDQJH
QWUR
LQJE
RDWH
SUHVVXUHZDVKLQJLQDFFRUGDQFHZLW
DWDQW VH
 KH
JKW
1R
W FR
D\
K,3.RYHUWKHHQWLUHFODPSUDQJ
LQVX U0
LQF
PL[
;FLV
X
YLQJ
RI OL
H
3DUW FDWLRQVP
OLJK
\DW
39&
DQG
XWGRRU
89' HV
PR
WLRQ
OGHG
HGE
VRIW
IRUPD
OH
7KH EOHIRUR
HPV
UR
JHFKLILW
QGVS
RUHLQ
LHOG
VKLH
V\VW
U
RQV 6XLWD PLF
QVDWL
KWVD
DPS
)RUP

; +(/8 [LEOHFRUU
IOH
Q
7HFK

'0
1'


8
862
+(/

+LJK

DWD

LFDOG

7HFKQ

QWDJH

$GYD
#

3KRW

R5

DOSK#

/DUP

FRP
DQQ

OH

FDE

7KH

FWV

HUIH

DS
IRU

OLFN

FRQG&

+(/8

$GYDQWDJHV ZWTWefTgk

KRZ

F
Y^S`V
fgTW

&

'

6KHOO

+LJKWLJKWQHVV

6HDO

/DUJHFODPSLQJUDQ
VK
WL
W
D
SVLGH
V D
OLJ
DWHVLR
IOLJH
DOOD
OLJK
KLV
SOHDVH
KDV VHDPQVGZ'LPHQ
ELQH
KLJK
7KHVL]HV00DQG0FRYH
LQVW
O RI
ZKLF
VXF DVH
,W
FRP
UFDEOHGLDPHWHUVIURPPPXSWR
RRU
QWUR
*NHU V\W,VW3SURWHFWLRQ
QDOV
EOH
QFH
PP
VLJ
RXWG
HFR
HGD
D HV
;FD
QW
DQG
U WK
VSH +LJK
XGLR
'0
WD
LPS
U
R
D
G
F
LV
R
I
X
I
VL
/DUJH
R
R
G
R
WHPSHUDWXUHUDQJH :HLJKW
LQ
QUHV
R
YHO
XLWH
WLQG
VLRQ
VL
WL
LQWU
D
R
LV
F
LF
8QLW
D
UU
O\V
&DQEHXVHGIRUWHPSHUDWXUHUDQJH
NJNP
VW
VP
&R
OH
HXVH
W
E
IRU
WHUL
Q
&WR
PLF VIURP
UDQ
D
F
WK
D
H
&
P
QD
W
U
LU
VH
G\
VW
H
Q\
UD

R
SD

Z
GLXV
UWK
GI
FKD
WUHVL
&RP
 UHX
LQJUD
SSO\

OLILH
GIR
%HQG
YDEOH
5RGHQW
6LPSOH


U VX
TXD
DVVHP
EO\
HXVH
VWDWLF
PP
LWLV
RZH
UHPR
DF
GLXV

OVRE
DS
&RQW
LQJUD 7KH+(/8723+7063OXVLVWHDV\WR

JODQG
%HQG
DQD
DVVHPEOH

U DV

7XEH
EOHF

HR
PP
H
2XWHU

ZLU
UHVV

H
$G
DEHOG
Q

PP
6KDSHO\GHVL

,QQHU
SKR
KHOXN

HU
XQG

VH

SRQ
JXHV
UHV  OORZLQJFDWDOR
[
D
)
HIR

RIWK
 GPHDFRQRSOR\ J\

*
+
#"

7HFKQLFDO'DWD

2SWLPDOVWUDLQUHOLHI

%UDVVQLFNHOSODWHG

EUDVVFKURPDWHG EODFN
%XQD1
2ULQJ
%XQD1
3URWHFWLRQFODVVLILFDWLRQ
,3EDU,3.

7HPSHUDWXUHUDQJH
&WR&
7HVWVWDQGDUG
(1

JQ

GH

ZZZ
OXNDEHO

7KH+(/8723+7063OXVLVFKDUDFWH

LQIR#KH
UL]HGE\DVXFFHVVIXOGH

VLJQ

$OVRDYDLODEOHDVDEODFNFKURPDWHG 

GHVLJQ
)D[


OGH

* VL]H
NDEH
OX
*/ WKUHDGOHQJWK
KH K

LFH
D[
R#
QJHQ3
H)
LQI
6: VSDQQHUVL]H
PL
UHTXHVW KRXWSULRUQRW
HP
3KRQ XQLWVRQ
HGZLW
+

 OHDVP D\EHFKDQJ
'

LRQVP
H 
YDLODE
$OVRD VDQGVSHFLILFDW 0DLO
'LHVHOVWUD )D[
LRQ
UV
(

HQV
UWH
ZZZKHOXNDEHOGH
'LP

GTXD
+(/8.$%(/*PE++HDGTXDUWHUV'

LHVHOVWUDH+HPPLQJHQ*HUPD 
++HD

Q\ 3KRQH)D[
/ *PE

.$%(
LQIR#KHOXNDEHOGH
K
+(/8
\ 3
PDQ
*HU
JHQ
PLQ
HP
+




3DUW1R

PP


&LW\

=,3




WU\

&RXQ

HQ
VHV
7HFK HV
XHV
GLD
J\
DORJ
0H
:LU
QROR
JFDW
OHV HVVRULHV
7HFK
ZLQ
&DE
FF
%XV
IROOR
OH$
RUN RIWKH
&DE
\
HWZ
YH
D1 HDFRS
QWDWL
'DW
VH
P
UH
HQG
UHS
VHV
N
WRU\
3OHD

EDF
IDF
H
FDOO IURPD
HOVWUD
LW
'LHV
$YLV
UV

3OHD

DUWH

('





GTX

(/

.$%

+(/8

*P

 +HD
E+

9

OH RFN
&DE
/RDG ODEOHH[VW
DYDL

XFWUDQJH
:LGHSURG
[VWRFN
DYDLODEOHH

/RDG&DEOH9DQ6G
2

GV
JODQ
3
06( I(0&FDEOH
3
2
7
R
+(/8 HUDWLRQ

Q
ZJH

/$
5)/9
(; ;3
9

3KRWR5DOSK#/DUPDQQFRP

1H

LINE

7HFKQL

FDO'

DWD
4XDOLW\LQHYHQWWHFK
LFDO'
7HFKQ QLTXH

DWD
WHPSH
UDW
&WR XUHUDQJH
PD[W &
QRP HPSDWFRQGX
LQDOYROW
FWRU
DFFRUGLQJ
DJH
&
WR9'(8

$&W 9'&FRQGXFW 89
HVW
PLQL YROWDJHRUFRQGXFWRU $&
PXPEH
9
IL[HGLQVW
QGLQJUD
IOH[LQJ DOODWLRQDSSUR[ GLXV
RFFDVLRQ
[RX
DO DSSUR
WHU
[[F 
&DEOH
DEOH
VWUXFWXU
H
EDUHFR
DFFRUGL SSHUWLQQHG
ILQ
QJ
,(& WR',19'( HO\VWUDQGHG
&O
GRXEOH FO
DVVDQ
G
,QVXODW LQVXODWHG
RXWHUVKLRQFURVVOLQNHG
VKHDWK HDWKFURVVOL 3RO\ROHILQ
QNHG
FRORXUV
EODFNUH 3RO\ROHILQ
GEOXH
3URS

G\
4XDOLW\LVDOVRYHU\LPSRUWDQWIRU
GER
HG V\VWHPV$VRIQRZZ
WKHHYHQW
*ODQ QLF
7HFKQLFDO'DWD
HDUH
NHOSODW
RIIHULQJWZRORDGFDEOHVWRJXDU
%UDVV DQWHHWKDW
LQJ
DFWVSU P WKHOLJKWVSHUIRUPSHUIHFWO\
7HPSHUDWXUHUDQJH
GXULQJWKHHQWLUHVKRZ7KHH[WUHP
&RQW HO\IOH[LEOH
%HU\OOLX
ORDGFDEOHV8 89
IL[HGLQVWDOODWLRQ&XSWR&
&RSSHU ULQJ
 7K
DQGORDGFDEOHV8 8
HSHUIH
J
DOLQ

GIRUFRPPRQPHFKDQLFDOGH
IOH[LQJ&XSWR&
6H9DUHXVH
FW
H
F
UHQ
DE
PDQGVIRU SURIHVVLRQDOVWDJHOLJK
:LWK RX
OHIRU EHQGLQJUDGLXV
0LQLPXP
1HRSWV\VWHPVD
LQVHUW QGRWKHUHOHFWULFDOORD
J
U 62/$
S
S RWR
Q
GFLU
WL
DP
5)/

FXLWVIURP 9WR97KH
IL[HGLQVWDOODK
(; ;
&O IOH[LELOLW\
WLRQ[RXW
GHVLJQD
YRHU
RXQ
OWDLFV\
39)
PLGH3$ LVDFKLHYHGE\YHU\ILQ
P
WHG*UHH
O\D
HZLUH
OH
3R
+(/8.$ XWHU
IOH[LQJ[R
Q/LQHZ

DE
VWHPV
VWUDQGLQJ GHVLJQ ZLWK  PP5LQJ
%(/  ZH
UHQHZDE
KLFKLVLQ
LQVHUWLQJ
7KH FRUHWR
 RIIHU
2 IOH[LEOH VWUDQGV
(DV\F
DQG
VKHDWK
OHHQHUJL
WKHVFRS
LPSOLI\
D SURGX
LQVXODWLRQDUHPDGHRI
HVDQGK &DEOHVWU
FWLRQ
%XQD1 URWHLVDOVRDYD
HPHQW
HRIRXU
HVW TXDOLW
XFWXUH
SULQJVV
FW LQ
RY
EOH FROGIOH[LEOH39&WKLV
WV
P
&D
DV
DF
V3
LODEOHDVD
RXU
QW
ORQJODVW
7h9DQG
0D[
\ VWDQG
FXVWR
HV
DGLDO
PL]HGSURG
DUGV W\S
9'(FHUW
LQJFRPP
,QJU
EOH XFW
2SHQFR
LDORUU
SOD
D[
%DUHFRSS
H
0LQ&D
HUILQHZLUH
LFD
HH
FH
LILFDWLFRQGXFWRUV
LWPHQW
O IRU +(
LQ RXUR
UDQJ
OH)U
,3
RQVDORQ
/8.$%(
ZQFDEOH
UDWXUH &
&RUHLQVXO
WKHFDE
JZ

SH
DWLRQ39&I
/
LWK
OH[LEOHDWORZ
P
DQ
IDFWRU\
 SURGX
GDQLQD
 WKHKLJK
7H
3DUW1R 8 8
WR
FWV 7K
LQ

FRVW

*HUPDQ
1RFRUHV[&XS2XWHU
WHPSHUDWXUH

H SURGX
HYHQ
\7KHUHI
FRUGLQJ&RQGPDNH
 [ 
XS HIIHFWLYHPDQ
FWLRQ WDN
FURVVVHF
RUHZILJXUHLPSU
&RUHFRORX
KHFDEOH
 PP XS
QH
WXUHGDF
HV
DSSPP
UEODFNZLWK
IW
UWR
DF
HF
PP
WR
XI
P
LQW
DQ
DUNHWUHT
 WR  [
DFWIOH[L
0DQ
DEOH WR
RYHPHQ


 PP JUHHQ\HO
EOHIDVW

*
ORZXLUHPHQWV
LDOP
 DUH DYD
[GHOLYHU62/
O
WR(1
&URVVVHF
RUUDG
RQWDFW
$5)/(;
LODE
2XWHUVKH

DWK39&IOH
RZOHYH 
EDOO\ LQ
OH IURP [LEOHDWORZ
HHD[LDO
WLRQVIUR
WO
IU
*
;
HD
6DIHF
EOH

VWD
39
QF
VWR
P
QD
)
[ QGDORQ
FN ,I UHT
VLVWD
XSWR
WHPSHUDWXUH
HDQG
IDFHVH
LRQUH
XLU

<RXUD

GREEN

)

DJHV
GYDQW

HUWLHV

DSSUR
YD
3I* O9'( 5HJ
8/RQUH   7h9
$FFRUGLQTXHVW5R+6D5 
39FDEOH JWR39)UHTQG&(FRPSOLDQ
W
R]RQH V'.(9'($ XLUHPHQWS
URILOHIRU
ZHDW UHVLVWDQWDFF .

KH
KDORJH UDQG89UH WR(1
VLVW
QI
(1 UHHDFFWR( DQWDFFWR+'
LQVXODWLR

[P
LQJ
VLW
HG
QH
1



DW

ZH
UDQ
WZ
*
P

$
UHVLVWD
7
 DUH
RUNHGV\
G

P7KH

[ QOD\HUV DUH
QWWRDFL
FORVHG
VWHPVDV

ZLUHLV
(QODUJH
DUH
VH

(1
EOD
WV
GD
WR

D
XVHGJ

FN VKHDWK
QGEDVHV
II FRORX
*
PRGXOH
QWDF

OR
UHGIURP
[
IODPHU
DFFWR
LQJ RQ
RU EUDQFK
ZKHQFR
QDWXUDO
HDFK RWK



HVL
RQRUR
ZLUH%
 IURP
9'( VWDQWDFFRUG
FRORXU


FH *
HU IRULP
SWLRQDOO\
RWK
[
FRQGXFWR
LQJWR
GLVWDQ
UHGRUE
SURYHG
,(& ',1
 \VPDOO

 IDF*
62/$5)/
U LQVXOD
HV
KDQGOLQJ
OXHVKHDW
RIE

(1
WLRQ LQ
(; ;39
YHU\UR 
[
WDFW

KLQJWRV
LRQSUR
WKH VWD

EX
)LQFU
FDOFRQ
LPSOLI\
QGDUG
9LEUDW 
DOVRDYDL
DFFWR', VWDQGDEUDL
HOHFWUL 
\ *
RVVVHFWLR

R
XW
YHU
ORF
ODE
IW
G
[
VL
DO
VRQ
H

LQ
OH
1(1
LQVWDOODW
HOL
UHVLVWDQ
QVIURP
VWUD
UHVLVWD
KHDY\
LRQ7Z
IRUSURIH HOGH,QDGGLWLRQZ
VWUDLQU DOVRDW
 UHOLHI
WVKHDW
[P
*
QWWRVKR 

LQ
HR
QJ
VWUDLQ
K
DE
ZLU
VVLR
[ QDODV
WRWKHLUG
IIHUSUH
PXSWR

UWFLUFX
 UHOLHI
H
LHOGL
HOXN
[P
(0&VK'LPHQVLRQVDQGVSHFLILFDWLRQVPD\EHFKDQJHGZLWKRXWSULRUQRWLFH


WHPSH RXEOHLQVXO LWVXSWR
ZZZK #KHOXNDEHOGH VHPEO\RISKRWRYRO DVVHPEOHGFDEOHV
PDUH


FRQQH
DQWLFLS UDWXUH& DWLRQVKRUWFLU&WKDQNV
LQIR
WDLFLQVWD

FWRUVDQ


FXLWV
OODWLRQV
K\GURO\DWHGVHUYLFHOLIVHF

GWRROV


(0& J
H\H
VLVDQGD

)D[
VKLHOGLQ
DUV
PPRQLDF

UHVLVWDQ
1R
QHZ


WH

V
LRQ
W
YHUV
KRQH
(0& J
LQJHQ3
+(/8.
VKLHOGLQ
Y
PP
HUV
DO
$%(/ *P
LRQ
DFWX
+H
E++

YHUVLRQ ZLWK8/DS
YHUVLRQ
HDGTXD
ZZZKHOXNDEHOGH
SU
VVH
UWHUV
DOOW\SH ZLWKURGHQW RYDORQUHTX
'LHVHOVWUD
'LHVHOVWUD
SURWHF
HVW
VZLWKP
UWHUV
H
WLRQDYDL
GTXD
HWHUPDUN
+
'LPHQVL
++HD
ODEOH
HPPLQ
RQVDQG
LQJ
JHQ*
VSHFLILF
/ *PE
.$%(

+(/8

SURR

UDWLRQ

R 9LE

HUPDQ\

3K

DWLRQVP



D\EHFK



)D[




DQJHGZ

LWKRXWS

ULRUQRWL

FH



LQIR#
KHOXNDE

HOGH

I8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Flat and
Ribbon Cables

J1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Flat and Ribbon Cables


Flat cables in PVC and neoprene design are used
as trailing cables for cranes, open eld conveyors
and shelve service devices.
Flat cables offer the following advantages:
Extremely small bending radius
High exibility
Minimum wastage of space
Packeting possibilities

An expert and proper installation is important to


ensure perfect functioning. Please follow the
corresponding tting instructions.
Flat cables according to UL-standard are available
on request.
Ribbon cables are ideal for use because of
the excellent exibility as connecting cable in
electronics and in control engineering.
J

J2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description

Page

PVC-flat (H05 VVH6-F/H07 VVH6-F),300/500V and 450/750V...................................................................................................................


NEO-Flat,(N)GFLGU..............................................................................................................................................................................
PVC-flat-CY,screened,

................................................................................................................................................
NEO-Flat-C,(MCHU) screened, EMC-preferred type ......................................................................................................................................
Ribbon Cables,Type L, Type L AWG 28, Type D ............................................................................................................................................
TUBEFLEX-Y,roundshaped flat ribbon cable for IDC-technique, pitch 1,27 mm ....................................................................................................
TUBEFLEX-(St)-CY,roundshaped flat ribbon cable, screened, for IDC-technique, pitch 1,27mm, EMC-preferred type......................................................
EMC-preferred type

J 4
J 5
J 6
J 7
J 8
J 9

J 10

J3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PVC-flat (H05 VVH6-F/H07 VVH6-F)

300/500V and 450/750V

Technical data

Cable structure

Properties

Special PVC-flat cable,


H05 VVH6-F to EN 50214
H07 VVH6-F to HD 359 S2
(25 mm and above in adapted)
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +80 C
Nominal voltage
H05 VVH6-F = up to 1 mm
U0/U 300/500V
H07 VVH6-F =1,5 mm U0/U 450/750 V
Test voltage
H05 VVH6-F = up to 1 mm 2000 V
H07 VVH6-F =1,5 mm 2500 V
Minimum bending radius
10x cable thickness
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, stranded to DINVDE0295


cl.5, BS6360 cl.5 and IEC60228 cl.5
Special PVC core insulation TI2 to
DINVDE0281 part1
Cores laying parallel
Core identification up to 5 cores to colour
code DINVDE0293
7 cores and above with number printing
Green-yellow earth core
Special PVC outer jacket TM2 to
DINVDE0281 part1
Colour black (RAL 9005)

Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
Extremely small bending radius
High flexibility
Minimum waste of space
Packeting possibility
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

Art.No. 27012 (6x4).


G = with green-yellow earth core

Application
PVC type of flat cables are used mainly as trailing cable for crane installations, floor conveyer systems and shelf control units.
Installation notes: See NEO flat at page J5.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
26980
4G0,75
26981
5G0,75
26982
6G0,75
26983
9G0,75
26984
10G0,75
26985
12G0,75
26986
16G0,75
26987
18G0,75
26988
20G0,75
26989
24G0,75
26990
3G1
26991
4G1
26992
5G1
26993
6G1
26994
9G1
26995
10G1
26996
12G1
26997
16G1
26998
18G1
26999
20G1
27000
24G1
27001
4G1,5
27002
5G1,5
27003
7G1,5
27004
8G1,5
27005
10G1,5
27006
12G1,5
27028
16G1,5
27030
24G1,5
27007
4G2,5
27008
5G2,5

Outer
dimension
approx. mm
4,3 x 12,6
4,3 x 16,1
4,3 x 19,4
4,3 x 26,4
4,3 x 30,1
4,3 x 33,8
4,3 x 44,4
4,3 x 49,2
4,3 x 55,0
4,3 x 65,6
4,5 x 10,8
4,5 x 13,4
4,5 x 16,0
4,5 x 20,6
4,5 x 28,4
4,5 x 30,0
4,5 x 36,2
4,5 x 47,6
4,5 x 52,8
4,5 x 59,0
4,5 x 70,4
4,5 x 13,7
4,5 x 17,9
4,5 x 23,5
4,5 x 26,8
4,5 x 33,5
4,5 x 38,9
4,5 x 51,5
4,5 x 83,0
5,5 x 17,0
5,5 x 21,5

Cop.
weight
kg/km
28,8
36,0
43,2
64,8
72,0
84,4
115,2
129,6
144,0
172,8
28,8
38,4
48,0
57,6
86,4
96,0
115,2
153,6
172,8
192,0
230,4
58,0
72,0
101,0
115,0
144,0
173,0
230,4
346,0
96,0
120,0

Weight
approx.
kg/km
90,0
115,0
141,0
198,0
224,0
258,0
340,0
380,0
424,0
509,0
80,0
104,0
134,0
161,0
230,0
256,0
298,0
395,0
441,0
495,0
590,0
133,0
169,0
235,0
265,0
332,0
421,0
555,0
820,0
205,0
256,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
14
14


Part no. No.cores x
cross-sec.
mm
27009
7G2,5
27010
8G2,5
27011
12G2,5
27029
16G2,5
27012
24G2,5
27027
24G2,5
27013
4G4
27014
5G4
27015
7G4
27016
4G6
27017
5G6
27018
7G6
27019
4G10
27020
4G16
27025
5G16
27021
4G25
27026
5G25
27022
4G35
27023
4G50
27024
4G70

Outer
dimension
approx. mm
5,5 x 30,3
5,5 x 31,9
5,8 x 47,1
5,8 x 55,1
15,0 x 63,0
5,8 x 120,0
7,0 x 21,8
7,0 x 27,4
7,9 x 36,6
8,2 x 24,8
8,2 x 31,8
8,2 x 42,6
10,0 x 29,6
11,2 x 34,4
13,0 x 46,6
13,7 x 42,6
15,5 x 55,5
15,4 x 47,6
18,2 x 57,0
20,0 x 64,2

Cop.
weight
kg/km
168,0
192,0
288,0
384,0
604,0
604,0
154,0
192,0
269,0
230,0
288,0
403,0
384,0
614,0
768,0
960,0
1200,0
1344,0
1920,0
2688,0

Weight
approx.
kg/km
344,0
389,0
580,0
674,0
950,0
950,0
344,0
428,0
590,0
424,0
530,0
760,0
710,0
1014,0
1370,0
1365,0
2000,0
2100,0
2940,0
4090,0

AWG-No.
14
14
14
14
14
14
12
12
12
10
10
10
8
6
6
4
4
2
1
2/0

Dimensions and specifications may be changed without prior notice. (RJ01)

J4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NEO-Flat (N)GFLGU


Technical data

Cable structure

Properties

Special Neoprene-flat cableadapted


toDINVDE0250 part809
Temperature range
flexing -25 C to +60 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Minimum bending radius
10x cable thickness
Radiation resistance
up to 50x106 cJ/kg (up to 50 Mrad)

Bare or tinnedcopper, stranded to


DINVDE0295, BS6360 cl.5 and IEC60228,
fine or extra fine wire stranded according
to different cross-sections
1 to 25mm - class6, col.4
35 to 95mm - class5
Special rubber core insulation GI1, to
DINVDE0207 part20
Core identification up to 5 cores, colour
code to DINVDE0293
7 cores and above with number printing
Cores laying parallel
Art.No. 28007 and 28013 cable structure
6x4
Green-yellow earth core
Special rubber outer sheath 5GM2, to
DINVDE0207 part21
Colour black

Special rubber outer sheath, cold-resistant


Extensively oil resistant, oil-/ chemical
Resistance - see table Technical
Informations
Extremely small bending radius
High flexibility
Minimum waste of space
Packeting possibility
Behaviour in fire:
Test according to VDE 0482-332-1-2, DIN
EN 60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Neoprene type of flat cables are used mainly as trailing cable for crane installations, floor conveyer systems and shelf control units.
These cables are also available for export with UL-approval on request.
Installation notes
Cables reels with flat cables must be transported in standing position on the flange. A bending flexibility can be achieved on a plane surface.
For this purpose, the corresponding fitting instructions should be followed.
Put the cable trolly on the guiding rail or upon carrier beam and push them together at the starting point. The distance between the
bedding surface of two cable trollys must be wider than the double thickness of a cable-packet.
During the packeting performance, it must be started with the smaller cross-section which lays on the bedding surface and will be builded
successively so that the biggest cross-section is laying on the top.
Further, be careful of a symmetrical load distribution.
In case of multicore flat cables with small cross-section, smaller than 2,5mm, is very critical due to its low tensile stress. In such case, you
should add 10% reserve wire for calculation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.cores x


cross-sec.
mm
28001
4G1,5
28002
5G1,5
28003
7G1,5
28004
8G1,5
28005
10G1,5
28006
12G1,5
28007
24G1,5 (6 x 4)
28008
4G2,5
28009
5G2,5
28010
7G2,5
28011
8G2,5
28012
12G2,5
28013
24G2,5 (6 x 4)
28014
4G4
28015
5G4
28016
7G4
28017
4G6
28018
5G6
28019
7G6
28020
4G10
28021
5G10

Outer
dimension
approx. mm
5,9 x 16,2
5,9 x 23,7
5,9 x 30,5
5,9 x 34,0
5,9 x 43,5
6,5 x 50,4
13,0 x 56,0
7,2 x 19,6
7,2 x 27,8
7,2 x 36,1
7,2 x 40,2
7,8 x 59,4
15,5 x 66,8
8,8 x 24,2
8,8 x 33,4
8,8 x 42,5
9,6 x 27,4
9,6 x 37,4
9,6 x 47,2
10,4 x 30,8
10,4 x 41,6

Cop.
weight
kg/km
58,0
72,0
101,0
115,0
144,0
173,0
346,0
96,0
120,0
168,0
192,0
288,0
576,0
154,0
192,0
269,0
230,0
288,0
403,0
384,0
480,0

Weight
approx.
kg/km
234,0
304,0
391,0
441,0
460,0
646,0
1290,0
316,0
391,0
533,0
602,0
890,0
1480,0
506,0
621,0
851,0
661,0
740,0
1004,0
1027,0
1171,0

AWG-No.
16
16
16
16
16
16
16
14
14
14
14
14
14
12
12
12
10
10
10
8
8


Part no. No.cores x
cross-sec.
mm
28022
4G16
28023
5G16
28024
4G25
28025
5G25
28026
7G25
28027
4G35
28028
5G35
28029
7G35
28030
4G50
28031
4G70
28032
4G95
28033
4G120

Outer
dimension
approx. mm
11,6 x 35,6
12,2 x 48,2
14,1 x 45,8
14,7 x 58,3
15,3 x 78,7
15,8 x 50,8
16,4 x 64,4
16,4 x 86,4
18,6 x 60,2
21,0 x 68,0
24,1 x 78,6
25,5 x 84,2

Cop.
weight
kg/km
614,0
768,0
960,0
1200,0
1680,0
1344,0
1680,0
2352,0
1920,0
2688,0
3648,0
4608,0

Weight
approx.
kg/km
1430,0
1590,0
1890,0
2215,0
3000,0
2460,0
2880,0
4100,0
3385,0
4480,0
5990,0
7240,0

AWG-No.
6
6
4
4
4
2
2
2
1
2/0
3/0
4/0

Dimensions and specifications may be changed without prior notice. (RJ01)

J5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PVC-flat-CY

screened, EMC-preferred type

Technical data

Cable structure

Properties

Special PVC-flat cable, screened, adapted


to DINVDE0283 part2
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Breakdown voltage
min. 6000 V
Minimum bending radius
15x cable thickness
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors


according to DINVDE0295 and IEC60228
cl.5, BS6360 cl.5
Special PVC insulation
Core identification see below
Cores screened individually or in bunches
Cores laying parallel
Copper screened braiding, approx. 85%
coverage
Special PVC outer jacket black (RAL 9005)

Extensively oil resistant


Extremely small bending radius
High flexibility
Minimum waste of space
Packeting possibility
The high degree of screening density
assures disturbance-free transmission of
all signal and impulses
PVC self-extinguishing and flameretardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.


Application
PVC screened flat cables are used mainly as trailing cable for crane installations, floor conveyer systems and shelf control units.
Installation notes
Cables reels with flat cables must be transported in standing position on the flange. A bending flexibility can be achieved on a plane surface.
For this purpose, the corresponding fitting instructions should be followed.
Put the cable trolly on the guiding rail or upon carrier beam and push them together at the starting point. The distance between the
bedding surface of two cable trollys must be wider than the double thickness of a cable-packet.
During the packeting performance, it must be started with the smaller cross-section which lays on the bedding surface and will be builded
successively so that the biggest cross-section is laying on the top.
Further, be careful of a symmetrical load distribution.
In case of multicore flat cables with small cross-section, smaller than 2,5mm, is very critical due to its low tensile stress. In such case, you
should add 10% reserve wire for calculation.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
27100
27101
27102
27090
27103
27091
27092
27093
27094
27104
27095
27096
27097
27098
27099

No.cores x
cross-sec.
mm
5G0,5
5 x 4x0,5
8 x 7x0,5
4G0,75
4 x 4G1
4G1,5
8G1,5
12G1,5
4G2,5
6G2,5
4G4
4G6
4G10
4G16
4G25

Core
marking
Colour coded, DIN VDE 0293
Colour coded
Cont. white numbering, DIN VDE 0293
Colour coded, DIN VDE 0293
Cont. white numbering
Colour coded, DIN VDE 0293
Cont. white numbering
Cont. white numbering
Colour coded, DIN VDE 0293
Cont. white numbering, DIN VDE 0293
Colour coded, DIN VDE 0293
Colour coded, DIN VDE 0293
Colour coded, DIN VDE 0293
Colour coded, DIN VDE 0293
Colour coded, DIN VDE 0293

Outer
dimension
approx. mm
21,0 x 3,4
37,4 x 7,2
68,6 x 11,7
15,0 x 5,0
33,5 x 11,0
18,7 x 5,9
35,6 x 5,9
52,1 x 5,9
21,0 x 6,9
37,4 x 7,2
24,5 x 7,7
30,1 x 9,2
35,8 x 10,5
41,3 x 12,6
48,4 x 14,4

Cop.
weight
kg/km
64,0
175,0
480,0
70,0
310,0
116,0
217,0
266,0
170,0
240,0
225,0
328,0
525,0
788,0
1170,0

Weight
approx.
kg/km
140,0
280,0
1180,0
147,0
625,0
210,0
400,0
610,0
270,0
320,0
400,0
520,0
840,0
1280,0
1800,0

AWG-No.
20
20
20
18
17
16
16
16
14
14
12
10
8
6
4

Dimensions and specifications may be changed without prior notice. (RJ01)

J6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NEO-Flat-C (MCHU) screened, EMC-preferred type




Technical data

Cable structure

Properties

Special-Neoprene-flat cable, screened,


adapted to DINVDE0250 part809
Temperature range
flexing -25 C to +60 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Minimum bending radius
approx. 15x cable thickness
Radiation resistance
up to 50x106 cJ/kg (up to 50 Mrad)

Bare or tinnedcopper, extra fine wire


conductors according to DINVDE0295 Kl.6
and IEC60228 cl.6, BS6360 cl.6
Special rubber core insulation
Core identification
up to 5 cores to colour code DINVDE0293
7 cores and above with number printing
Cores screened individually
Cores laying parallel
Copper screened braiding, approx. 85%
coverage
Special Neoprene outer jacket black
(RAL9005)

Outer jacket cold resistant


Extensively oil resistant
Extremely small bending radius
High flexibility
Minimum waste of space
Packeting possibility
The high degree of screening density
assures disturbance-free transmission of
all signal and impulses
Behaviour in fire
Test according to VDE 0482-332-1-2, DIN
EN 60332-2-1/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)


Note

G = with green-yellow earth core.


AWG sizes are approximate equivalent
values. The actual cross-section is in mm.


Application
Neoprene screened flat cables are used mainly as trailing cable for crane installations, floor conveyer systems and shelf control units. These
cables are also available for export with UL-approval on request.
Installation notes
Cables reels with flat cables must be transported in standing position on the flange. A bending flexibility can be achieved on a plane surface.
For this purpose, the corresponding fitting instructions should be followed.
Put the cable trolly on the guiding rail or upon carrier beam and push them together at the starting point. The distance between the
bedding surface of two cable trollys must be wider than the double thickness of a cable-packet.
During the packeting performance, it must be started with the smaller cross-section which lays on the bedding surface and will be builded
successively so that the biggest cross-section is laying on the top.
Further, be careful of a symmetrical load distribution.
In case of multicore flat cables with small cross-section, smaller than 2,5mm, is very critical due to its low tensile stress. In such case, you
should add 10% reserve wire for calculation.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.cores x


cross-sec.
mm
28100
8G1,5
28101
12G1,5
28102
4G2,5

Outer
dimension
approx. mm
7,9 x 42,0
7,9 x 61,0
8,5 x 25,5

Cop.
weight
kg/km
231,0
346,0
164,0

Weight
approx.
kg/km
520,0
790,0
420,0

AWG-No.
16
16
14


Part no. No.cores x
cross-sec.
mm
28103
6G2,5
28104
12G2,5
28302
4G25

Outer
dimension
approx. mm
8,5 x 34,5
8,9 x 68,0
16,0 x 51,0

Cop.
weight
kg/km
247,0
494,0
1116,0

Weight
approx.
kg/km
540,0
1000,0
1650,0

AWG-No.
14
14
14

Dimensions and specifications may be changed without prior notice. (RJ01)

J7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Ribbon Cables

Type L, Type L AWG 28, Type D

Technical data

Cable structure

Properties

Type L (stranded wire)


Pitch 2,54 mm
Nominal voltage
0,14 mm = 350 V
0,25 to 0,75 mm = 600 V
Test voltage
0,14 mm = 1200 V
0,25 to 0,75 mm = 2000 V
Type L AWG 28 (stranded wire)
Pitch 1,27 mm
Heat-resistance up to 105 C
Nominal voltage 300 V
Test voltage 2000 V
Type D (solid)
Pitch 2,5 mm
Nominal voltage 500 V
Test voltage 1500 V

Type L (stranded wire)


Tinned copper, fine wire stranded to
DINVDE0295 cl.5, BS6360 cl.5
PVC core insulation, flame retardant
Cores colour coded
Type L AWG 28 (stranded wire)
Tinned copper 7x0,127
PVC core insulation, flame retardant
Cores moulded, can be separated easily
Cores single coloured, edge marking on
one side
Type D (solid)
Cu-solid, tinned 0,5mm
PVC core insulation
Cores moulded, can be separated easily
Cores colour coded

Type L AWG 28 ( stranded wire)


PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)

Application
Ribbon cables are used as connecting and control cables wherever there is a need to install quickly and with a minimum waste of space.
These cables offer an excellent degree of flexibility.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Typ L (colour coded)


Part no.
44001
44002
44003
44004
44005
44006
44007
44008
44009
44010
44011
44012
44013
44014
44015
44016
44017
44018
44019
44020
44021
44022
44023
44024
44025
44026
44027
44028
44029
44030
44031
44032
44033
44034
44035
44036
44037
44038
44039
44040

No.cores x
cross-sec.
mm
2 x 0,14
3 x 0,14
4 x 0,14
5 x 0,14
6 x 0,14
7 x 0,14
8 x 0,14
9 x 0,14
10 x 0,14
11 x 0,14
12 x 0,14
16 x 0,14
20 x 0,14
4 x 0,25
5 x 0,25
6 x 0,25
7 x 0,25
8 x 0,25
10 x 0,25
12 x 0,25
16 x 0,25
20 x 0,25
4 x 0,5
5 x 0,5
6 x 0,5
7 x 0,5
8 x 0,5
10 x 0,5
12 x 0,5
16 x 0,5
20 x 0,5
4 x 0,75
5 x 0,75
6 x 0,75
7 x 0,75
8 x 0,75
10 x 0,75
12 x 0,75
16 x 0,75
20 x 0,75

Outer
Cop.
approx. mm weight
kg/km
3,9 x 1,4
2,7
6,4 x 1,4
4,0
8,9 x 1,4
5,4
11,3 x 1,4
6,7
13,9 x 1,4
8,1
16,4 x 1,4
9,4
18,9 x 1,4
10,7
21,4 x 1,4
13,4
23,9 x 1,4
14,4
26,4 x 1,4
15,3
28,9 x 1,4
16,1
38,9 x 1,4
21,5
48,9 x 1,4
27,0
9,1 x 1,6
9,6
11,6 x 1,6
12,0
14,1 x 1,6
14,4
16,6 x 1,6
16,8
19,1 x 1,6
19,2
24,1 x 1,6
24,0
29,1 x 1,6
28,8
39,1 x 1,6
38,4
49,1 x 1,6
48,0
9,0 x 2,0
19,2
12,0 x 2,0
24,0
15,0 x 2,0
28,8
17,0 x 2,0
33,6
20,0 x 2,0
38,4
23,0 x 2,0
48,0
30,0 x 2,0
58,0
40,0 x 2,0
77,0
50,0 x 2,0
101,0
10,6 x 2,5
29,0
13,3 x 2,5
36,0
16,0 x 2,5
43,2
18,7 x 2,5
50,0
21,4 x 2,5
58,0
26,8 x 2,5
72,0
32,2 x 2,5
86,0
43,0 x 2,5
112,0
53,4 x 2,5
151,0

Weight
approx.
kg/km
7,0
11,0
14,0
18,0
21,0
25,0
28,0
32,0
35,0
39,0
42,0
56,0
70,0
21,0
26,0
31,0
36,0
42,0
52,0
62,0
83,0
104,0
38,0
48,0
57,0
66,0
76,0
95,0
114,0
151,0
190,0
52,0
64,0
77,0
90,0
103,0
130,0
155,0
206,0
260,0

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
26
26
24
24
24
24
24
24
24
24
24
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18

Typ L AWG 28 (single coloured, edge marking on one side)


Part no.
44041
44042
44043
44044
44045
44046
44047
44048

No.cores x
cross-sec.
mm
10 x 0,08
14 x 0,08
16 x 0,08
20 x 0,08
26 x 0,08
34 x 0,08
40 x 0,08
48 x 0,08

Outer
Cop.
approx. mm weight
kg/km
12,7 x 0,9
13,4
17,8 x 0,9
18,0
20,3 x 0,9
20,0
25,4 x 0,9
25,0
33,0 x 0,9
32,0
43,2 x 0,9
43,0
50,8 x 0,9
48,0
61,0 x 0,9
59,0

Weight
approx.
kg/km
30,0
50,0
53,0
65,0
75,0
90,0
125,0
145,0

AWG-No.

Outer
Cop.
approx. mm weight
kg/km
3,9 x 1,4
10,0
6,4 x 1,4
14,0
8,9 x 1,4
19,0
11,4 x 1,4
24,0
13,9 x 1,4
29,0
16,4 x 1,4
34,0
18,9 x 1,4
38,0
21,4 x 1,4
42,0
23,9 x 1,4
48,0
26,4 x 1,4
56,0

Weight
approx.
kg/km
10,0
14,0
17,0
21,0
25,0
29,0
33,0
37,0
41,0
47,0

AWG-No.

28
28
28
28
28
28
28
28

Typ D (colour coded)


Part no.
44049
44050
44051
44052
44053
44054
44055
44056
44057
44058

No.cores x
cross-sec.
mm
2 x 0,5
3 x 0,5
4 x 0,5
5 x 0,5
6 x 0,5
7 x 0,5
8 x 0,5
9 x 0,5
10 x 0,5
11 x 0,5

20
20
20
20
20
20
20
20
20
20

Dimensions and specifications may be changed without prior notice. (RJ01)

J8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TUBEFLEX-Y

roundshaped flat ribbon cable for IDC-technique, pitch 1,27 mm

Technical data

Cable structure

Properties

Roundshaped special Flat Ribbon Cable


Conductor resistance at 20 C
max. 230 Ohm/km
Temperature range
-20 C up to +80 C
Voltage rating max. 300 V
Test voltage
core/core 2000 V
Dielectric strength, Spark-test
3000 V
Insulation resistance
min. 20 MOhm x km
Capacitance (side cores)
ca. 75 pF/m
Impedance 115 Ohm
Minimum bending radius
15x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Stranded tinned copper conductor,


size AWG 28
7x0,127 mm = 0,09 mm
Special PVC core insulation, adapted to
DINVDE0207 part4
Cores colour grey, edge marking on one
side
Cores laying parallel and adjacent,
alternately spliced or separated and
periodically slotted
Roundshaped flat ribbon cable, folded
Taping
Special PVC outer sheath, adapted to
DINVDE0207 part5
Colour grey

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Very interesting for cable
pre-assemblers!

Application
TUBEFLEX-Y Flat ribbon cable, due to its roundshape offers considerable advantages compared with other flat ribbon cables during the
installation and assembly. This roundshaped cable bids enormous profits by using the quick and economical possibilities under continuance
with the efficient connection in IDC-technique. All conductors can be contacted at one working procedure without stripping the insulation.
The accurate to size pitch-image of the ribbon cable is obtained due to an adapted backshaping before the plug installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part
no.

45130
45131
45132
45133
45134
45135
45136
45137

No.cores Flat ribbon


x AWG-no. dimension
Width mm

9 x 28
10 x 28
14 x 28
16 x 28
20 x 28
24 x 28
25 x 28
26 x 28

11,43
12,70
17,78
20,30
25,40
30,48
31,75
33,02

Outer
Outer Cop.
Weight
jacket
approx. weight approx.
nominal mm
kg/km kg/km
wallthickness
mm
0,8
6,1
8,7
35,0
0,8
6,2
9,7
36,0
0,8
7,2
13,6
48,0
0,8
7,2
15,5
51,0
0,8
7,3
19,4
57,0
0,8
8,6
23,2
66,0
0,8
8,6
24,2
69,0
0,8
8,6
25,2
70,0


Part
no.

45138
45139
45140
45141
45142
45143
45144
45145

No.cores Flat ribbon


x AWG-no. dimension
Width mm

30 x 28
34 x 28
36 x 28
37 x 28
40 x 28
50 x 28
60 x 28
64 x 28

38,10
43,20
45,72
47,00
50,80
63,50
76,20
81,30

Outer
Outer Cop.
Weight
jacket
approx. weight approx.
nominal mm
kg/km kg/km
wallthickness
mm
0,8
9,0
29,0
81,0
0,8
10,0
32,9
87,0
0,8
10,2
34,9
91,0
1,0
10,3
35,8
93,0
1,0
10,7
38,7
101,0
1,0
11,1
48,4
118,0
1,0
12,5
58,1
135,0
1,0
13,0
62,0
147,0

Dimensions and specifications may be changed without prior notice. (RJ01)

J9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TUBEFLEX-(St)-CY

roundshaped flat ribbon cable, screened, for IDC-technique,

pitch 1,27mm, EMC-preferred type




Technical data

Cable structure

Properties

Roundshaped special Flat Ribbon Cable,


screened
Conductor resistance at 20 C
max. 230 Ohm/km
Temperature range
-20 C up to +80 C
Voltage rating max. 300 V
Test voltage
core/core 2000 V
core/screen 2000 V
Dielectric strength, Spark-test
3000 V
Insulation resistance
min. 20 MOhm x km
Capacitance (side cores)
ca. 75 pF/m
Impedance 115 Ohm
Minimum bending radius
15x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Stranded tinned copper conductor,


size AWG 28
7x0,127 mm = 0,09 mm
Special PVC core insulation, adapted to
DINVDE0207 part4
Cores colour grey, edge marking on one
side
Cores laying parallel and adjacent,
alternately spliced or separated and
periodically slotted
Roundshaped flat ribbon cable, folded
Dual shielding:
(St) - plastic coated Alu-foil and
C - tinned copper wire braiding with
optimal surface coverage
Special PVC outer sheath, adapted to
DINVDE0207 part5
Colour grey

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Very interesting for cable
pre-assemblers!
The dual shielding with plastic coated
aluminium foil (St) and the additional tinned
copper wire braiding (C) protects against
high frequency interference and ensures
disturbance-free signal and impuls transfer.

Application
TUBEFLEX-(St)-CY Flat ribbon cable, due to its roundshape offers considerable advantages compared with other flat ribbon cables during
the installation and assembly.
This roundshaped cable bids enormous profits by using the quick and economical possibilities under continuance with the efficient connection
in IDC-technique. All conductors can be contacted at one working procedure without stripping the insulation. The accurate to size pitch-image
of the ribbon cable is obtained due to an adapted backshaping before the plug installation.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part
no.

45150
45151
45152
45153
45154
45155
45156
45157
45158
45159
45160

No.cores Flat ribbon


x AWG-no. dimension
Width mm

9 x 28
10 x 28
14 x 28
16 x 28
20 x 28
24 x 28
25 x 28
26 x 28
30 x 28
34 x 28
36 x 28

11,43
12,70
17,78
20,30
25,40
30,48
31,75
33,02
38,10
43,20
45,72

Outer
Outer Cop.
Weight
jacket
approx. weight approx.
nominal mm
kg/km kg/km
wallthickness
mm
0,8
6,3
30,9
56,0
0,8
6,4
31,9
57,0
0,8
7,2
35,6
70,0
0,8
7,4
42,0
75,0
0,8
7,8
45,8
83,0
0,8
9,0
54,3
97,0
0,8
9,0
55,2
100,0
0,8
9,0
60,0
101,0
0,8
9,2
60,4
113,0
0,8
10,2
68,1
122,0
0,8
10,4
70,1
126,0


Part
no.

45161
45162
45163
45164
45165

No.cores Flat ribbon


x AWG-no. dimension
Width mm

37 x 28
40 x 28
50 x 28
60 x 28
64 x 28

47,00
50,80
63,50
76,20
81,30

Outer
Outer Cop.
Weight
jacket
approx. weight approx.
nominal mm
kg/km kg/km
wallthickness
mm
1,0
10,5
71,1
128,0
1,0
11,3
74,1
135,0
1,0
11,6
88,3
160,0
1,0
12,9
98,7
172,0
1,0
13,3
107,2
192,0

Dimensions and specifications may be changed without prior notice. (RJ01)

J 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Single Conductors

K1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Single Conductors
Single cores are necessary for efcient use
in switch cabinets wiring or cable assemblies.
Whether PVC, Silicone, Fluorinated polymeric or
Rubber insulated, with plain or tinned copper
conductors, HELUKABEL has an extended stock
with nearly all popular colour combinations.
We produce special colour combinations
upon request. For all two or three coloured
combinations please take our program for vehicle
cables (pages K 41 - K 44).
These products are dispatched in cardboard boxes,
coils, non-returnable reels or in cardboard barrels.
Several sizes of reels or barrels are available.

K2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description
LiYv,PVC-Single Cores, fine wire stranded, tinned .......................................................................................................................................
H05 V-K,PVC-Single Cores, fine wire stranded ................................................................................................................................

H07 V-K / (H)07 V-K,PVC-Single Cores, fine wire stranded ..............................................................................................................

H05 V-U / (H)05 V-U / (H)07 V-U,PVC-single cores, fine wire stranded, VDE 0281 approved ......................................................................
H07 V-R / H05 V-K / (H)07 V-K**,PVC-single cores, fine wire stranded, VDE 0281 approved ................................................................

LifY Single Core,extra fine wires with highest flexibility .................................................................................................................................

PUR Single Core,cold resistant, halogen-free ............................................................................................................................................

H05Z-K / H07Z-K,rubber insulated single core, halogen-free ..........................................................................................................................


H05G-U / -K / H07G-U / -R / -K......................................................................................................................................................

LiYW / H05 V2-K,PVC-Single Cores, 90C, heat-resistant ................................................................................................................................

HELUTHERM 125-J/-O,extra flexible, halogen-free, temperature resistant, meter marking...................................................................................


H07 V2-K,PVC single core, 90C, heat resistant ....................................................................................................................................

HELUTHERM 145,flexible, cross-linked, halogen-free .............................................................................................................................


SiF / SiFF,silicon single cores, halogen-free .............................................................................................................................................

SiF/GL, SiD, SiD/GL,silicon single cores, halogen-free ..............................................................................................................................

FZ-LSi / FZ-LS / Neon Light Cables.....................................................................................................................................................

HELUFLON-FEP-6Y,fluorinated polymeric materials, single core, -100C to +205C..............................................................................................

HELUFLON-PTFE-5Y,fluorinated polymeric materials, single core, 600V / 1000V.................................................................................................


HELUTHERM 400,Insulation class C.........................................................................................................................................................

HELUTHERM 600 / 600-ES,halogen-free / high-grade steel braiding............................................................................................................


HELUTHERM 800 / 800-ES,halogen-free / high-grade steel braiding............................................................................................................
HELUTHERM 1200 / 1200-ES,halogen-free / high-grade steel braiding........................................................................................................
Earth Conductors ESUY and ESY........................................................................................................................................................
H01N2-D / -E,100 V, VDE approved, welding cable...................................................................................................................................

NSGAFU 3kV,Special Rubber-Insulated Cable, VDE approved, short-circuit up to 1000V.....................................................................................

NSHXAF 3kV,halogen-free Special Rubber-Insulated Cable, VDE approved, short-circuit up to 1000V....................................................................


KOMPOSPEED 600 / 600-C, 0,6/1kV double-insulated, halogen-free, special single cores for drag chains, EMC-preferred type...........................

HELUTRAIN 3GKW,Train-Cable, robust special single core, halogen-free, 0,6/1kV, meter marking............................................................................
HELUTRAIN 4GKW-AXplus,Train-Cable, robust special single core, halogen-free, 1,8/3kV, meter marking................................................................

Vehicle Cable FLY,one colour / two colour (old type FLK), according to DIN ISO 6722.............................................................................................
Vehicle Cable FLY,one colour / two colour (old type FLK), according to DIN ISO 6722.............................................................................................
Vehicle Cable FLY,one colour / two colour (old type FLK), according to DIN ISO 6722.............................................................................................

Vehicle Cable FLRY,FLRY-Type A (FLK-R) / -Type B (FLK-D)..............................................................................................................................

Page
K 4
K 6
K 8

K 10
K 11
K 14
K 15
K 16
K 18
K 19
K 20
K 21
K 22
K 24
K 25
K 26
K 27
K 28
K 29
K 30
K 31
K 32
K 33
K 34
K 35
K 36
K 37
K 39
K 40
K 41
K 42
K 43
K 44

K3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LiYv PVC-Single Cores, fine wire stranded, tinned




Technical data

Cable structure

Properties

PVC single cores to DINVDE0812


LiYv(tinned)
Temperature range
flexing -5 C to +70 C
fixed installation -30 C to +80 C
Operating peak voltage
LiYv(tinned)
0,14 mm 500 V
0,25-1,50 mm 900 V
Test voltage
LiY(tinned)
0,14 mm 1200 V
0,25-1,50 mm 2500 V
Insulation resistance
min. 10 MOhm x km
Minimum bending radius
12,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Tinned copper fine wire stranded to


DINVDE0295 cl.5, BS6360 cl.5, HD383
and IEC60228 cl.5
PVC core insulation, compound YI3 to
DINVDE0812
Core colours see below


PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

For two-coloured combinations ring


marking.

Application
PVC insulated flexible hook-up wires are used for the connection for low voltage applications, communication apparatus, electronic assemblies
and equipment, racks, switchboards etc. correspondingly of VDE 0800 part 1 for the temperature range up to +70 C.
Those stranded hook-up wires are not permitted to install for heavy current application outside of the equipment.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


LiYv / mm
CrossOuter
section mm
mm
approx. RAL


Cop.
weight
kg/km

black

gn-ye

blue

brown

red

white

grey

vio

ye

pink

green

trans

dk-bu

og

o.col.

2-col.

9005

5015

8003

3000

9003

7000

4005

1021

3015

6018

5010

2003

26405

26406

26407

26408

26409

26410

26411

26412

26413

26414

26415

26416

26417

26418

26419

26420

26421

26422

26423

26424

26425

26426

26427

26428

26429

26430

26431

26432

26433

26434

26435

26436

Spool (standard 100m capacity)

Packing
LIY
Part no.
0,14
Part no.
0,25
Part no.
0,5
Part no.
0,75
Part no.
1
Part no.
1,5

1,1

1,4

1,3

2,4

1,8

4,8

2,0

7,2

2,1

9,6

2,6

14,4

26437

26438

26439

26440

26441

26442

26443

26444

26445

26446

26447

26448

26449

26450

26451

26452

26453

26454

26455

26456

26457

26458

26459

26460

26461

26462

26463

26464

26465

26466

26467

26468

26469

26470

26471

26472

26473

26474

26475

26476

26477

26478

26479

26480

26481

26482

26483

26484

26485

26486

26487

26488

26489

26490

26491

26492

26493

26494

26495

26496

26497

26498

26499

26500

Continuation

K4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LiYv PVC-Single Cores, fine wire stranded, tinned


LiYv / mm
CrossOuter
section mm
mm
approx. RAL


Cop.
weight
kg/km

black

gn-ye

blue

brown

red

white

grey

vio

ye

pink

green

trans

dk-bu

og

o.col.

2-col.

9005

5015

8003

3000

9003

7000

4005

1021

3015

6018

5010

2003

Barrel (with various capacity)

Packing
LIY
Part no.
0,25
Part no.
0,5
Part no.
0,75
Part no.
1
Part no.
1,5

1,4

2,4

1,95

4,8

2,15

7,2

2,25

9,6

2,75

14,4

26505

26506

26507

26508

26509

26510

26511

26512

26513

26514

26515

26516

26517

26518

26519

26520

26521

26522

26523

26524

26525

26526

26527

26528

26529

26530

26531

26532

26533

26534

26535

26536

26537

26538

26539

26540

26541

26542

26543

26544

26545

26546

26547

26548

26549

26550

26551

26552

26553

26554

26555

26556

26557

26558

26559

26560

26561

26562

26563

26564

26565

26566

26567

26568

26569

26570

26571

26572

26573

26574

26575

26576

26577

26578

26579

26580

26581

26582

26583

26584

Dimensions and specifications may be changed without prior notice.

Conduits
Corrugated tubes
for standard applications
for lager sizes
scissile corrugated tubes
conduit glands
High exible conduits
plastic conduits with spiral spring
metal conduits
conduits glands
Conduit for heavy mechanical duty
metal conduits with plastic sheat
plastic conduits
conduits glands for metal conduits

You can nd conduits in our catalogue Cable Accessories.

K5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H05 V-K

PVC-Single Cores, fine wire stranded

Technical data

Cable structure

Properties

PVC single cores to DINVDE0281-3


H05 V-K/H05 V-U to DINVDE0281 part3,
HD21.3S3 and IEC60227-3
Temperature range
flexing -5 C to +70 C
fixed installation -30 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage H05 V-K 2000 V
Insulation resistance
min. 10 MOhm x km
Minimum bending radius
12,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper fine wire stranded to


DINVDE0295 cl.5, BS6360 cl.5, HD383
and IEC60228 cl.5
PVC core insulation, compound TI1 to
DINVDE00281 part3, HD21.3S3 and
IEC60227-3
Core Identification as per
DINVDE0293
The following colours are recommended:
black, white, blue, grey, brown, red,
orange, turquoise, violet and pink.
Exceptions are the colours green and
yellow; these are only permitted if the
safety regulations allows. Green is
permitted for the identification of
luminous decorative chains. All
two-coloured combinations of the above
single colours are allowed

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

d-bl = dark blue (RAL approx. 5010)


u-bl = ultramarin blue (RAL approx. 5002)

Application
These insulated wires are determined for the installation to the inside of apparatus as well as for the protective laying to the lightings, in
dry rooms, in production facilities, switch and distributor boards, in tubes, under and surface mounting of plasters.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


H05 V-K/mm
Crosssection
mm
approx.


Outer
Cop.
black
min. - max. weight
mm
kg/km
RAL
9005

gn-ye

blue

brown

red

white

grey

vio

ye

pink

green

trans

dk-bu

og

o.col.

2-col.

u-blue

5015

8003

3000

9003

7001

4005

1021

3015

6018

5010

2003

5002

Coil in cardboard (100m)

Packing
H05 V-K
Part no.
0,5
2,1 - 2,5
Part no.
0,75
2,2 - 2,7
Part no.
1
2,4 - 2,8

4,8
7,2
9,6

29081

29082

29083

29084

29085

29086

29087

29088

29089

29090

29091

29092

29093

29094

29095

29096

26386

29097

29098

29099

29100

29101

29102

29103

29104

29105

29106

29107

29108

29109

29110

29111

29112

26387

29113

29114

29115

29116

29117

29118

29119

29120

29121

29122

29123

29124

29125

29126

29127

29128

26388

Spool (with various capacity)

Packing
H05 VPart no.
0,5
Part no.
0,75
Part no.
1

2,1 - 2,5

4,8

2,2 - 2,7

7,2

2,4 - 2,8

9,6

26590

26591

26592

26593

26594

26595

26596

26597

26598

26599

26600

26601

26602

26603

26604

26605

26389

26606

26607

26608

26609

26610

26611

26612

26613

26614

26615

26616

26617

26618

26619

26620

26621

26390

26622

26623

26624

26625

26626

26627

26628

26629

26630

26631

26632

26633

26634

26635

26636

26637

26391

Continuation

K6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H05 V-K

PVC-Single Cores, fine wire stranded

H05 V-K/mm
Crosssection
mm
approx.


Outer
Cop.
black
min. - max. weight
mm
kg/km
RAL
9005

gn-ye

blue

brown

red

white

grey

vio

ye

pink

green

trans

dk-bu

og

o.col.

2-col.

u-blue

5015

8003

3000

9003

7001

4005

1021

3015

6018

5010

2003

Barrel (with various capacity)

Packing
H05 V-K
Part no.
0,5
2,1 - 2,5
Part no.
0,75
2,2 - 2,7
Part no.
1
2,4 - 2,8

4,8
7,2
9,6

26640

26641

26642

26643

26644

26645

26646

26647

26648

26649

26650

26651

26652

26653

26654

26655

26392

26656

26657

26658

26659

26660

26661

26662

26663

26664

26665

26666

26667

26668

26669

26670

26671

26393

26672

26673

26674

26675

26676

26677

26678

26679

26680

26681

26682

26683

26684

26685

26686

26687

26394

Dimensions and specifications may be changed without prior notice. (RK01)

Photo: Robert Brkle GmbH

K7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H07 V-K / (H)07 V-K

PVC-Single Cores, fine wire stranded

Technical data

Cable structure

Properties

PVC single cores to DINVDE0281 part3,


HD21.3S3 and IEC60227-3
Temperature range
flexing -5 C to +70 C
fixed installation -30 C to +80 C
Nominal voltage U0/U 450/750 V
Test voltage 2500 V
Insulation resistance
min. 10 MOhm x km
Minimum bending radius
12,5 to 15x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper fine wire stranded to


DINVDE0295 cl.5, BS6360 cl.5, HD383
and IEC60228 cl.5
PVC core insulation, compound TI1 to
DINVDE0281 part3, HD21.3S3 and
IEC60227-3
Core colours see below
Core Identification with nominal
voltage U0/U450/750 V
The following colours are recommended
(only single colour): black, white, blue, grey,
brown, red, orange, turquoise, violet and
pink. Two-coloured combinations are not
allowed, with exceptions of green-yellow.
Colour code Single core cables H07
see Technical Informations

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

Colours yellow, green, transparent only in


(H)07 V-K available.
Two-coloured combination is only
permitted for (H)07 V-K.


Application
These insulated wires are suitable for laying in tubes, under and surface mounting of plasters and also in closed installation conduits.
These are not allowed to install for direct laying on cable trays, channels or tanks. These types are permitted for the inner wiring of equipment,
distributor and switchboards and also for protective laying to the lightings with a nominal voltage up to 1000 V alternating current or up to
750 V direct current against earth.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


H07 V-K, (H)07 V-K/mm


CrossOuter
Cop.
section min. - max. weight
mm
mm
kg/km
approx. RAL


black

gn-ye

blue

brown

red

white

grey

vio

ye

pink

green

trans

dk-bu

og

2-col.

u-blue

9005

5015

8003

3000

9003

7001

4005

1021

3015

6018

5010

2003

5002

Coil in cardboard (100m)

Packing
H07 V-K
Part no.
1,5
Part no.
2,5
Part no.
4
Part no.
6

2,8 - 3,4

14,4

3,4 - 4,1

24,0

3,9 - 4,8

38,0

4,4 - 5,3

58,0

29129

29130

29131

29132

29133

29134

29135

29136

29137

29138

29139

29140

29141

29142

29144** 26395

29145

29146

29147

29148

29149

29150

29151

29152

29153

29154

29155

29156

29157

29158

29160

26396

29161

29162

29163

29164

29165

29166

29167

29168

29169

29170

29171

29172

29173

29174

29176

26397

29177

29178

29179

29180

29181

29182

29183

29184

29185

29186

29187

29188

29189

29190

29192

26398

Spool (with various capacity)

Packing
H07 V-K
Part no.
1,5
Part no.
2,5
Part no.
4
Part no.
6

2,8 - 3,4

14,4

3,4 - 4,1

24,0

3,9 - 4,8

38,0

4,4 - 5,3

58,0

26690

26691

26692

26693

26694

26695

26696

26697

26698

26699

26700

26701

26702

26703

26705** 26399

26706

26707

26708

26709

26710

26711

26712

26713

26714

26715

26716

26717

26718

26719

26721

26400

26722

26723

26724

26725

26726

26727

26728

26729

26730

26731

26732

26733

26734

26735

26737

26401

26738

26739

26740

26741

26742

26743

26744

26745

26746

26747

26748

26749

26750

26751

26753

26402

Continuation

K8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H07 V-K / (H)07 V-K

PVC-Single Cores, fine wire stranded

H07 V-K, (H)07 V-K/mm


CrossOuter
Cop.
section min. - max. weight
mm
mm
kg/km
approx. RAL


black

gn-ye

blue

brown

red

white

grey

vio

ye

pink

green

trans

dk-bu

og

2-col.

u-blue

9005

5015

8003

3000

9003

7001

4005

1021

3015

6018

5010

2003

Barrel (with various capacity)

Packing
H07 V-K
Part no.
1,5
Part no.
2,5
Part no.
4
Part no.
6

2,8 - 3,4

14,4

3,4 - 4,1

24,0

3,9 - 4,8

38,0

4,4 - 5,3

58,0

26755

26756

26757

26758

26759

26760

26761

26762

26763

26764

26765

26766

26767

26768

26770

26403

26771

26772

26773

26774

26775

26776

26777

26778

26779

26780

26781

26782

26783

26784

26786

26404

26787

26788

26789

26790

26791

26792

26793

26794

26795

26796

26797

26798

26799

26800

26802

26819

26803

26804

26805

26806

26807

26808

26809

26810

26811

26812

26813

26814

26815

26816

26818

26820

26060

26061

26062

26063

26064

26065

26066

26067

26068

26069

26092

26099

26108

26109

26111

26821

26112

26113

26114

26115

26116

26117

26118

26119

29855

29856

29857

29858

29859

29890

29892

26822

Coil in foil (100m)

Packing
H07 V-K
Part no.
1,5
Part no.
2,5
Part no.
4
Part no.
6
Part no.
10
Part no.
16
Part no.
25
Part no.
35
Part no.
50
Part no.
70
Part no.
95
Part no.
120
Part no.
150
Part no.
185
Part no.
240

2,8 - 3,4

14,4

3,4 - 4,1

24,0

3,9 - 4,8

38,0

4,4 - 5,3

58,0

5,7 - 6,8

96,0

6,7 - 8,1

154,0

8,4 - 10,2

240,0

9,7 - 11,7

336,0

11,5 - 13,9

480,0

13,2 - 16,0

672,0

15,1 - 18,2

912,0

16,7 - 20,2

1152,0

18,6 - 22,5

1440,0

20,6 - 24,9

1776,0

23,5 - 28,4

2304,0

29893

29894

29895

29896

29897

29898

29899

29905

29906

29907

29908

29909

29910

29911

29913

26823

29914

29915

29916

29917

29918

29919

29921

29922

29923

29924

29925

29926

29927

29928

29933

26824

29193

29194

29195

29196

29197

29198

29199

29200

29201

29202

29203

29204

29205

29206

29208

29209

29210

29211

29212

29213

29214

29215

29216

29217

29218

29219

29220

29221

29222

29224

29225

29226

29227

29228

29229

29230

29231

29232

29233

29234

29235

29236

29237

29238

29240

29241

29242

29243

29244

29245

29246

29247

29248

29249

29250

29251

29252

29253

29254

29256

29257

29258

29259

29260

29261

29262

29263

29264

29265

29266

29267

29268

29269

29270

29272

29273

29274

29275

29276

29277

29278

29279

29280

29281

29282

29283

29284

29285

29286

29288

29289

29290

29291

29292

29293

29294

29295

29296

29297

29298

29299

29300

29301

29302

29304

29418

29419

29420

29421

29422

29423

29424

29425

29426

29427

29428

29429

29430

29431

29433

29434

29435

29436

29437

29438

29439

29440

29441

29442

29443

29444

29445

29446

29447

29449

29494

29495

29496

29497

29498

29499

29590

29591

29592

29593

29594

29595

29596

29597

29599

29813

29814

29815

29816

29817

29818

29819

29840

29841

29842

29843

29844

29845

29846

29848

Drum

Packing
H07 V-K
Part no.
10
Part no.
16
Part no.
25
Part no.
35
Part no.
50
Part no.
70
Part no.
95
Part no.
120
Part no.
150
Part no.
185
Part no.
240

5,7 - 6,8

96,0

6,7 - 8,1

154,0

8,4 - 10,2

240,0

9,7 - 11,7

336,0

11,5 - 13,9

480,0

13,2 - 16,0

672,0

15,1 - 18,2

912,0

16,7 - 20,2

1152,0

18,6 - 22,5

1440,0

20,6 - 24,9

1776,0

23,5 - 28,4

2304,0

26825

26826

26827

26828

26829

26830

26831

26832

26833

26834

26835

26836

26837

26838

26840

26841

26842

26843

26844

26845

26846

26847

26848

26849

26850

26851

26852

26853

26854

26856

26857

26858

26859

26860

26861

26862

26863

26864

26865

26866

26867

26868

26869

26870

26872

26873

26874

26875

26876

26877

26878

26879

26880

26881

26882

26883

26884

26885

26886

26888

26889

26890

26891

26892

26893

26894

26895

26896

26897

26898

26899

26900

26901

26902

26904

26905

26906

26907

26908

26909

26910

26911

26912

26913

26914

26915

26916

26917

26918

26920

26921

26922

26923

26924

26925

26926

26927

26928

26929

26930

26931

26932

26933

26934

26936

29305

29306

29307

29308

29309

29310

29311

29312

29313

29314

29315

29316

29317

29318

29320

29321

29322

29323

29324

29325

29326

29327

29328

29329

29330

29331

29332

29333

29334

29336

29337

29338

29339

29340

29341

29342

29343

29344

29345

29346

29347

29348

29349

29350

29352

29353

29354

29355

29356

29357

29358

29359

29360

29361

29362

29363

29364

29365

29366

29368

Dimensions and specifications may be changed without prior notice. (RK01)

K9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H05 V-U / (H)05 V-U / (H)07 V-U

PVC-single cores, fine

wire stranded, VDE 0281 approved




H05 V-U, (H)05 V-U/mm


CrossOuter
Cop.
section min. - max. weight
mm
mm
kg/km
approx. RAL


black

gn-ye

blue

brown

red

white

grey

vio

o.col.

o.col.

o.col.

o.col.

o.col.

o.col.

o.col.

o.col.

9005

5015

8003

3000

9003

7001

4005

Coil in cardboard (100m)

Packing
H05 V-U
Part no.
0,5
Part no.
0,75
Part no.
1

1,9 - 2,3

4,8

2,1 - 2,5

7,2

2,2 - 2,7

9,6

28761

28762

28763

28764

28765

28766

28767

28768

28769

28770

28771

28772

28773

28774

28775

28776

28777

28778

28779

28780

28781

28782

28783

28784

26937

26938

26939

26940

26941

26942

26943

26944

26945

26946

26947

26948

26949

26950

26951

26952

26953

26954

26955

26956

26957

26958

26959

26960

Spool (with various capacity)

Packing
H05 V-U
Part no.
0,5
Part no.
0,75
Part no.
1

1,9 - 2,3

4,8

2,1 - 2,5

7,2

2,2 - 2,7

9,6

Coil in cardboard (100m)

Packing
H07 V-U
Part no.
1,5
Part no.
2,5
Part no.
4
Part no.
6
Part no.
10

2,6 - 3,2

14,4

3,2 - 3,9

24,0

3,6 - 4,4

38,0

4,1 - 5,0

58,0

5,3 - 6,4

96,0

28785

28786

28787

28788

28789

28790

28791

28792

28793

28794

28795

28796

28797

28798

28799

28800

28801

28802

28803

28804

28805

28806

28807

28808

28809

28810

28811

28812

28813

28814

28815

28816

28817

28818

28819

28820

28821

28822

28823

28824

Drum

Packing
H07 V-U
Part no.
1,5
Part no.
2,5
Part no.
4
Part no.
6
Part no.
10

2,6 - 3,2

14,4

3,2 - 3,9

24,0

3,6 - 4,4

38,0

4,1 - 5,0

58,0

5,3 - 6,4

96,0

28145

28146

28147

28148

28149

28150

28151

28152

28153

28154

28155

28156

28157

28158

28159

28160

28161

28162

28163

28164

28165

28166

28167

28168

28169

28170

28171

28172

28173

28174

28175

28176

28177

28178

28179

28180

28181

28182

28183

28184

Dimensions and specifications may be changed without prior notice. (RK01)

K 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H07 V-R / H05 V-K / (H)07 V-K**

PVC-single cores,

fine wire stranded, VDE 0281 approved




H07 V-R/mm
CrossOuter
Cop.
section min. - max. weight
mm
mm
kg/km
approx. RAL


black

gn-ye

blue

brown

red

white

grey

vio

o.col.

o.col.

o.col.

o.col.

o.col.

o.col.

o.col.

o.col.

9005

5015

8003

3000

9003

7001

4005

Coil in foil

Packing
H07 V-R
Part no.
16
Part no.
25
Part no.
35
Part no.
50
Part no.
70
Part no.
95
Part no.
120
Part no.
150
Part no.
185
Part no.
240

6,4 - 7,8

154,0

8,1 - 9,7

240,0

9,0 - 10,9

336,0

10,6 - 12,8

480,0

12,1 - 14,6

672,0

14,1 - 17,1

912,0

15,6 - 18,8

1152,0

17,3 - 20,9

1440,0

19,3 - 23,3

1776,0

22,0 - 26,6

2304,0

28825

28826

28827

28828

28829

28830

28831

28832

28833

28834

28835

28836

28837

28838

28839

28840

28841

28842

28843

28844

28845

28846

28847

28848

28849

28850

28851

28852

28853

28854

28855

28856

28857

28858

28859

28860

28861

28862

28863

28864

28865

28866

28867

28868

28869

28870

28871

28872

28873

28874

28875

28876

28877

Drum

Packing
H07 V-R
Part no.
16
Part no.
25
Part no.
35
Part no.
50
Part no.
70
Part no.
95
Part no.
120
Part no.
150
Part no.
185
Part no.
240

6,4 - 7,8

154,0

8,1 - 9,7

240,0

9,0 - 10,9

336,0

10,6 - 12,8

480,0

12,1 - 14,6

672,0

14,1 - 17,1

912,0

15,6 - 18,8

1152,0

17,3 - 20,9

1440,0

19,3 - 23,3

1776,0

22,0 - 26,6

2304,0

28185

28186

28187

28188

28189

28190

28191

28192

28193

28194

28195

28196

28197

28198

28199

28200

28201

28202

28203

28204

28205

28206

28207

28208

28209

28210

28211

28212

28213

28214

28215

28216

28217

28218

28219

28220

28221

28222

28223

28224

28225

28226

28227

28228

28229

28230

28231

28232

28233

28234

28235

28236

28237

Dimensions and specifications may be changed without prior notice. (RK01)

K 11
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H05 V-K / (H)07 V-K**

PVC-single cores, fine wire stranded, VDE 0281 approved

K 12
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H05 V-K, H07 V-K


PVC-Single Cores to VDE 0281

= The product is conformed with the EC Low-Voltage Directive 73/23/EWG and 93/68/EWG.

Barrels, one-way barrels or barrels on hire


Type
cross section
2
mm
LiY
0,25
0,50
0,75
1,00
1,50

Type
cross section
2
mm
H05 V-K
H07 V-K
0,50
0,75
1,00
1,50
2,50
4,00
6,00

Type
cross section
2
mm
H05 V-K
H07 V-K
0,50
0,75
1,00
1,50
2,50

one-way cardboard
8-on guar
dimension
in mm

ca. contents
in m

500 x 500 x 420


500 x 500 x 420
500 x 500 x 420
500 x 500 x 420
500 x 500 x 420

10000
7000
5000
4000
3000

one-way barrels
8-on guar
dimension
in mm

ca. contents
in m

400 x 400 x 500


400 x 400 x 500
400 x 400 x 500
400 x 400 x 500
400 x 400 x 500
400 x 400 x 500
400 x 400 x 500

4000
3500
3000
2000
1200
900
800

one-way barrels
8-on guar
dimension
in mm

ca. contents
in m

400 x 400 x 800


400 x 400 x 800
400 x 400 x 800
400 x 400 x 800
400 x 400 x 800

7000
6000
5200
3500
2000

Delivery for one-way barrel

Works photo: HELUKABEL

The materials used in manufacture are cadmium-free and


contain no silicone and free from substances harmful to
the wetting properties of lacquers
PVC self-extinguishing and ame retardant according
to DIN VDE 0482-332-1-2, DIN EN 60332-1-2/IEC 60332-1
(equivalent DIN VDE 0472 part 804 test method B)

K = Fine stranded conductor

K 13
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LifY Single Core

extra fine wires with highest flexibility

Technical data

Cable structure

Properties

Special PVC insulated extra fine stranded


wire
Extreme flexible by special design
Adapted to DINVDE0250, 0281, 0295
Temperature range
flexing -15 C to +80 C
Operating voltage
up to 0,25 mm 300 V
(not for purposes of high current and
power installation)
Nominal voltage
0,5 mm up to 1 mm U0/U 300/500 V
from 1,5 mm U0/U 450/750 V
Test voltage
up to 0,25 mm = 2 kV
0,5 - 1 mm = 2,5 kV
from 1,5 mm = 3 kV
Bending radius, flexing
approx. 8x cable

Bare copper, extra fine wire conductors,


bunch stranded, see table below
PVC-core insaulation with plasticized and
elastic PVC

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
Please complete the part number for these
cables by adding the suffix for the colour
required as per the list:
00 = green, 01 = black, 02 = red,
03 = blue, 04 = brown, 05 = white,
06 = grey, 07 = violet, 08 = yellow,
09 = orange, 10 = transparent,
11 = pink, 12 = beige, 13 = twin colour

Application
The LifY single cores are used as super flexible insulated strand wires for switch cabinets, as measuring cable for testing, laboratories, research
etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part
no.

Core
colour

151xx
152xx
153xx
154xx
155xx
156xx
157xx
158xx
159xx
15093
15135
15115
15116
15114
15094
15136
15118
15119
15117
15095
15137
15121
15122
15120
15096
15138
15124
15125
15123

black
gn-ye
blue
brown
red
black
gn-ye
blue
brown
red
black
gn-ye
blue
brown
red
black
gn-ye
blue
brown
red

Cross- Cond.
Outer Cop.
Weight
section make-up
approx. weight approx.
mm (nom. val.) mm
kg/km kg/km
n x wire
0,1
51 x 0,05
1,0
1,2
2,1
0,14
72 x 0,05
1,0
1,4
2,6
0,25
65 x 0,07
1,0
2,5
4,2
0,5
132 x 0,07
2,0
5,5
8,0
0,75
195 x 0,07
2,2
8,0
12,0
1
260 x 0,07
2,5
10,8
18,0
1,5
192 x 0,1
3,5
15,0
22,0
2,5
320 x 0,1
3,8
25,0
37,0
4
512 x 0,1
4,9
40,0
50,0
6
768 x 0,1
6,0
60,0
71,0
6
768 x 0,1
6,0
60,0
71,0
6
768 x 0,1
6,0
60,0
71,0
6
768 x 0,1
6,0
60,0
71,0
6
768 x 0,1
6,0
60,0
71,0
10
1280 x 0,1
7,3
100,0
130,0
10
1280 x 0,1
7,3
100,0
130,0
10
1280 x 0,1
7,3
100,0
130,0
10
1280 x 0,1
7,3
100,0
130,0
10
1280 x 0,1
7,3
100,0
130,0
16
2048 x 0,1
8,8
160,0
187,0
16
2048 x 0,1
8,8
160,0
187,0
16
2048 x 0,1
8,8
160,0
187,0
16
2048 x 0,1
8,8
160,0
187,0
16
2048 x 0,1
8,8
160,0
187,0
25
3234 x 0,1
10,5
240,0
294,0
25
3234 x 0,1
10,5
240,0
294,0
25
3234 x 0,1
10,5
240,0
294,0
25
3234 x 0,1
10,5
240,0
294,0
25
3234 x 0,1
10,5
240,0
294,0

AWG-No.

26
24
20
18
17
16
14
12
10
10
10
10
10
8
8
8
8
8
6
6
6
6
6
4
4
4
4
4


Part
no.

Core
colour

15097
15139
15127
15128
15126
15098
15140
15130
15131
15129
15099
15141
15133
15134
15132

black
gn-ye
blue
brown
red
black
gn-ye
blue
brown
red
black
gn-ye
blue
brown
red

Cross- Cond.
Outer Cop.
Weight
section make-up
approx. weight approx.
mm (nom. val.) mm
kg/km kg/km
n x wire
35
4508 x 0,1
11,7
336,0
380,0
35
4508 x 0,1
11,7
336,0
380,0
35
4508 x 0,1
11,7
336,0
380,0
35
4508 x 0,1
11,7
336,0
380,0
35
4508 x 0,1
11,7
336,0
380,0
50
6468 x 0,1
14,7
480,0
521,0
50
6468 x 0,1
14,7
480,0
521,0
50
6468 x 0,1
14,7
480,0
521,0
50
6468 x 0,1
14,7
480,0
521,0
50
6468 x 0,1
14,7
480,0
521,0
70
8967 x 0,1
15,5
672,0
740,0
70
8967 x 0,1
15,5
672,0
740,0
70
8967 x 0,1
15,5
672,0
740,0
70
8967 x 0,1
15,5
672,0
740,0
70
8967 x 0,1
15,5
672,0
740,0

AWG-No.

2
2
2
2
2
1
1
1
1
1
2/0
2/0
2/0
2/0
2/0

Dimensions and specifications may be changed without prior notice. (RK01)

K 14
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR Single Core

cold resistant, halogen-free

Technical data

Cable structure

Properties

PUR-single cores, halogen-free


Temperature range
-40 C to +80 C
(up to +100 C for short time)
Operating voltage 1000 V
Test voltage
3500 V, 15 minutes
Minimum bending radius
occasionally moved 10x core
without movement 5x core
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Plain copper conductors fine stranded to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special PUR core insulation

Halogen-free
Flexible at low temperatures up to -40 C
Resistant against pressure
Overroll steady
Cut and scratchproof
Resistant to
Oil
Petrol
See and waste water
Acids
Lye
UV-radiation

Application
PUR-single cores are suited for installation in switch cabinets, cable assemblies and electronic equipment. Inductive loops in the road surface
for controlling of light signalling equipment.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



CrossOuter
Cop.
section
approx. mm weight
mm
kg/km
approx. RAL
Part no.
0,5
2,2
4,8
Part no.
0,75
2,4
7,2
Part no.
1
2,5
9,6
Part no.
1,5
3,0
14,4
Part no.
2,5
3,7
24,0
Part no.
4
4,3
38,0
Part no.
6
5,1
58,0
Part no.
10
6,8
96,0
Part no.
16
7,8
154,0
Part no.
25
10,0
240,0
Part no.
35
11,4
336,0
Part no.
50
13,2
480,0
Part no.
70
15,4
672,0
Part no.
95
17,7
912,0
Part no.
120
19,2
1152,0
Part no.
150
22,0
1440,0

green
6018

black
9005

blue
5015

brown
8003

red
3000

white
1013

grey
7000

vio
4005

ye
1021

og
2003

trans
-

pink
3015

dk-bu
5010

beige
1001

2-col.
-

50650
50665
50680
50695
50710
50725
50740
50755
50770
50785
50800
50815
50830
50845
50860
50875
-

50651
50666
50681
50696
50711
50726
50741
50756
50771
50786
50801
50816
50831
50846
50861
50876
-

50652
50667
50682
50697
50712
50727
50742
50757
50772
50787
50802
50817
50832
50847
50862
50877
-

50653
50668
50683
50698
50713
50728
50743
50758
50773
50788
50803
50818
50833
50848
50863
50878
-

50654
50669
50684
50699
50714
50729
50744
50759
50774
50789
50804
50819
50834
50849
50864
50879
-

50655
50670
50685
50700
50715
50730
50745
50760
50775
50790
50805
50820
50835
50850
50865
50880
-

50656
50671
50686
50701
50716
50731
50746
50761
50776
50791
50806
50821
50836
50851
50866
50881
-

50657
50672
50687
50702
50717
50732
50747
50762
50777
50792
50807
50822
50837
50852
50867
50882
-

50658
50673
50688
50703
50718
50733
50748
50763
50778
50793
50808
50823
50838
50853
50868
50883
-

50659
50674
50689
50704
50719
50734
50749
50764
50779
50794
50809
50824
50839
50854
50869
50884
-

50660
50675
50690
50705
50720
50735
50750
50765
50780
50795
50810
50825
50840
50855
50870
50885
-

50661
50676
50691
50706
50721
50736
50751
50766
50781
50796
50811
50826
50841
50856
50871
50886
-

50662
50677
50692
50707
50722
50737
50752
50767
50782
50797
50812
50827
50842
50857
50872
50887
-

50663
50678
50693
50708
50723
50738
50753
50768
50783
50798
50813
50828
50843
50858
50873
50888
-

50664
50679
50694
50709
50724
50739
50754
50769
50784
50799
50814
50829
50844
50859
50874
50889
-

Dimensions and specifications may be changed without prior notice. (RK01)

K 15
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H05Z-K / H07Z-K

rubber insulated single core, halogen-free

Technical data

Cable structure

Properties

Rubber-insulated single core cables for low


emission of smoke and corrosive gases in
case of fire to VDE0282 part9 and
HD22.9S2
Conductor resistance
according to DINVDE0295 cl.5
Temperature range
-40 C to +90 C
Permissible working temperature
at the conductor +90 C
Nominal voltage
H05Z-K U0/U 300/500 V
H07Z-K U0/U 450/750 V
Test voltage 2500 V
Minimum bending radius
approx. 8x core
Radiation resistance
up to 20x106 cJ/kg (up to 20 Mrad)

Bare copper conductor, finewire stranded


according to DINVDE0295 cl.5, BS6360
cl.5, IEC60228, HD383
Core identification according to
DINVDE0293
Separator over conductor permitted
Core insulation of cross-linked polyolefin,
compound type EI5 to DINVDE0282 part1
Core colors see table below,
dark blue and orange on request
LS0H = Low Smoke Zero Halogen-free.

The materials used in manufacture are


cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Tests
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Ozone resistant according to EN60811-2-1
/ HD505.2.1
Smoke density according to VDE0482
part1034-1+2, DINEN61034-1+2/
IEC61034-1+2, BS7622 part1+2 (equivalent
DINVDE0472 part816)


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application
Halogen-free single-core wires are used for installation in dry environments for wiring up lighting fixtures and units where valuable assets
are to protected from further damage resulting from fire. These cables may be installed on, in and beneath plaster, as well as in closed
installation ducts. The direct operating voltage is permitted up to 900 V against ground when they are used in rail-coaches. For the inner
wiring of switch boards and distributors are to be used with an alternating nominal voltage up to 1000 V or a direct voltage up to 750 V
against ground.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


H05Z-K
Crosssection
mm
Part no.
0,5
Part no.
0,75
Part no.
1

Core
Cop.
min. - max. weight
mm
kg/km

Weight
approx.
kg/km

2,1 - 2,6

4,8

9,0

2,2 - 2,8

7,2

12,4

2,4 - 2,9

9,6

15,0

black

gn-ye

blue

brown

red

white

grey

vio

dk-bu

ye

og

u-blue

52872
52881
52890
-

52873
52882
52891
-

52874
52883
52892
-

52875
52884
52893
-

52876
52885
52894
-

52877
52886
52895
-

52878
52887
52896
-

52879
52888
52897
-

52945
52947
52949
-

52880
52889
52898
-

52946
52948
52950
-

53071
53072
53073
-

black

gn-ye

blue

brown

red

white

grey

vio

dk-bu

ye

og

u-blue

51768
51777
51786
51795
51804
51813
51822
51831
51840
-

51769
51778
51787
51796
51805
51814
51823
51832
51841
-

51770
51779
51788
51797
51806
51815
51824
51833
51842
-

51771
51780
51789
51798
51807
51816
51825
51834
51843
-

51772
51781
51790
51799
51808
51817
51826
51835
51844
-

51773
51782
51791
51800
51809
51818
51827
51836
51845
-

51774
51783
51792
51801
51810
51819
51828
51837
51846
-

51775
51784
51793
51802
51811
51820
51829
51838
51847
-

52951
52953
52955
52957
52959
52961
52963
52965
52967
-

51776
51785
51794
51803
51812
51821
51830
51839
51848
-

52952
52954
52956
52958
52960
52962
52964
52966
52968
-

53074
53075
53076
53077
53078
53079
53080
53081
53082
-

H07Z-K
Crosssection
mm
Part no.
1,5
Part no.
2,5
Part no.
4
Part no.
6
Part no.
10
Part no.
16
Part no.
25
Part no.
35
Part no.
50

Core
Cop.
min. - max. weight
mm
kg/km

Weight
approx.
kg/km

2,8 - 3,5

14,4

24,0

3,4 - 4,3

24,0

35,0

3,9 - 4,9

38,0

51,0

4,4 - 5,5

58,0

71,0

5,7 - 7,1

96,0

118,0

6,7 - 8,4

154,0

180,0

8,4 - 10,6

240,0

278,0

9,7 - 12,1

336,0

375,0

11,5 - 14,4

480,0

560,0

Continuation

K 16
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H05Z-K / H07Z-K

rubber insulated single core, halogen-free

H07Z-K
Crosssection
mm
Part no.
70
Part no.
95
Part no.
120
Part no.
150
Part no.
185
Part no.
240

Core
Cop.
min. - max. weight
mm
kg/km
13,2 - 16,6

672,0

Weight
approx.
kg/km
780,0

15,1 - 18,8

912,0

952,0

16,7 - 20,9

1152,0

1200,0

18,6 - 23,3

1440,0

1505,0

20,6 - 25,8

1776,0

1845,0

23,5 - 29,4

2304,0

2400,0

black

gn-ye

blue

brown

red

white

grey

vio

dk-bu

ye

og

u-blue

51849
51858
51867
51876
51885
51894
-

51850
51859
51868
51877
51886
51895
-

51851
51860
51869
51878
51887
51896
-

51852
51861
51870
51879
51888
51897
-

51853
51862
51871
51880
51889
51898
-

51854
51863
51872
51881
51890
51899
-

51855
51864
51873
51882
51891
51900
-

51856
51865
51874
51883
51892
51901
-

52969
52971
52973
52975
52977
52979
-

51857
51866
51875
51884
51893
51902
-

52970
52972
52974
52976
52978
52980
-

53083
53084
53085
53086
53087
53088
-

black

gn-ye

blue

brown

red

white

grey

vio

dk-bu

ye

og

u-blue

52809
52821
52833
-

52810
52822
52834
-

52811
52823
52835
-

52812
52824
52836
-

52813
52825
52837
-

52814
52826
52838
-

52815
52827
52839
-

52816
52828
52840
-

52817
52829
52841
-

52819
52831
52843
-

black

gn-ye

blue

brown

red

white

grey

vio

dk-bu

ye

og

u-blue

52845
52857
-

52846
52858
-

52847
52859
-

52848
52860
-

52849
52861
-

52850
52862
-

52851
52863
-

52852
52864
-

52853
52865
-

52855
52867
-

H05Z-K
Barrel (with various capacity)

Packing
Crosssection
mm
Part no.
0,5
Part no.
0,75
Part no.
1

Core
Cop.
min. - max. weight
approx. mm kg/km

Weight
approx.
kg/km

2,1 - 2,6

4,8

9,0

2,2 - 2,8

7,2

12,4

2,4 - 2,9

9,6

15,0







H07Z-K
Barrel (with various capacity)

Packing
Crosssection
mm
Part no.
1,5
Part no.
2,5

Core
Cop.
min. - max. weight
approx. mm kg/km

Weight
approx.
kg/km

2,8 - 3,5

14,4

24,0

3,4 - 4,3

24,0

35,0

Dimensions and specifications may be changed without prior notice. (RK01)

K 17
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H05G-U / -K / H07G-U / -R / -K


Technical data

Cable structure

Properties

Heat-resistant (+120 C) rubber-insulated


cable to DINVDE0282 part7 and
HD22.7S2
Max. permissible operating temperature
at conductor +110 C
Lowest ambient temperatures
flexing up to -25 C
fixed installation up to -40 C
Nominal voltage
H05G U0/U 300/500 V
H07G U0/U 450/750 V
Test voltage
H05G 2000 V
H05G 2500 V
Minimum bending radius
approx.7x cable

Tinned copper conductor to DINVDE0295


and IEC60228, BS6360 and HD383
single wire, solid: class 1
multi stranded wires: class 2
fine wires: class 5
Rubber core insulation, compound type
EI3 (EVA) to DINVDE0282 part7
(DINVDE0207 part20)
Separating layer over tinned conductor is
optional
Core identification to DINVDE0293
Standard colour black

Single core colours green and yellow can


only be applied where the safety
regulations are allowed
The identification for the lighting chain
cable is green permitted


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
Please quote the individual part-no. in your
order with the codes for core colours of
the key-positions.
00 = green
01 = black
02 = blue
03 = brown
04 = grey
05 = orange
06 = pink
07 = turquoise
08 = white
09 = violet
10 = yellow
11 = green-yellow
bare conductor on request


Application
For inside wiring of switch boards and distributors as well as of operating parts such as in or on lights, for the connection of electric heaters
with a nominal voltage up to 1000 V alternating voltage or up to 750 V direct voltage against ground.
The cables are all allowed for laying in tubes, on and under the plaster.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


H05G-U (single wire)


Part no.
541__
542__
543__

Cross-sec.
mm
0,5
0,75
1

Outer
min. - max.
mm
1,9 - 2,4
2,1 - 2,6
2,2 - 2,8

Cop.
weight
kg/km
4,8
7,2
9,6

Weight
approx.
kg/km
10,0
15,0
16,0

AWG-No.
20
18
17

H07G-U (single wire)


Part no.
544__
545__
546__

Cross-sec.
mm
1,5
2,5
4

H05G-K (fine wire)

H07G-K (fine wire)

Part no.
550__
551__
552__

Cross-sec.
mm
0,5
0,75
1

Outer
min. - max.
mm
2,1 - 2,6
2,2 - 2,8
2,4 - 2,9

Cop.
weight
kg/km
4,8
7,2
9,6

Weight
approx.
kg/km
13,0
16,0
22,0

AWG-No.
20
18
17

Part no.
553__
554__
555__
556__
557__
558__
559__
560__
561__
562__
563__
564__

Cross-sec.
mm
1,5
2,5
4
6
10
16
25
35
50
70
95
120

Outer
min. - max.
mm
2,8 - 3,5
3,4 - 4,3
4,0 - 5,0

Cop.
weight
kg/km
14,4
24,0
38,0

Weight
approx.
kg/km
24,0
35,0
53,0

AWG-No.

Outer
min. - max.
mm
3,0 - 3,7
3,6 - 4,5
4,3 - 5,4
4,8 - 6,0
6,0 - 7,6
7,1 - 8,9
8,8 - 11,0
10,1 - 12,6
11,9 - 14,9
13,6 - 17,0
15,5 - 19,3
17,1 - 21,4

Cop.
weight
kg/km
14,4
24,0
38,0
58,0
96,0
154,0
240,0
336,0
480,0
672,0
912,0
1152,0

Weight
approx.
kg/km
24,0
42,0
61,0
78,0
130,0
212,0
323,0
422,0
527,0
726,0
937,0
1192,0

AWG-No.

Outer
min. - max.
mm
4,7 - 5,9
6,0 - 7,4
6,8 - 8,5

Cop.
weight
kg/km
58,0
96,0
154,0

Weight
approx.
kg/km
72,0
123,0
184,0

AWG-No.

16
14
12

16
14
12
10
8
6
4
2
1
2/0
3/0
4/0

H07G-R (multi wire)


Part no.
547__
548__
549__

Cross-sec.
mm
6
10
16

10
8
6

Dimensions and specifications may be changed without prior notice. (RK01)

K 18
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LiYW / H05 V2-K

PVC-Single Cores, 90C, heat-resistant

Technical data

Cable structure

Properties

Special PVC single core with increased


heat-resistance LiYW up to 105 C adapted
to DINVDE0281 H05V2-K to 90 C
according to DINVDE0281 part7 and
HD21.7S2
Temperature range
LiYW
flexing +5 C to +105 C
fixed installation -10 C to +105 C
H05 V2-K
flexing +5 C to + 90 C
Nominal voltage
LiYW: U0/U 300/500 V
H05 V2-K: U0/U 300/500 V
Test voltage 2000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
approx. 10-15x core
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Plain copper conductors to DINVDE0295,


cl.5, IEC60228 cl.5, BS6360 cl.5 and
HD383 (0,5mm and above)
for 0,14mm = 18x0,1mm
0,25mm = 14x0,15mm
Special heat-resistant core insulation
LiYW up to +105 C adapted to
DINVDE0207
H05 V2-K up to +90 C, core insulation
heat-resistant TI3 to DINVDE0281 part7
Cores colour coded or on request
numbered according to DINVDE0293


Heat-resistant special PVC compound of


selected stabilizer and plasticizer
All requirements and test methods
conform DIN VDE 0281 part 7, deviates
however the maximal permissible operating
temperature up to +105 C for LiYW
Not to be used in contact with objects
higher than 85 C
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application
Therm insulated wires are ideal for use in power current installation, switch cabinets, motors and transformers which are subject to direct
contact with high temperatures (e.g. varnishing machines and drying towers etc.). These are also suitable for inside wiring of electrical
equipments such as lighting and heating apparatus.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


LiYW 105C
Cross-sec.
mm
Part no.
0,14
Part no.
0,25
Part no.
0,5

Core
mm

Cop.
weight
kg/km

Weight
approx.
kg/km

22,0

1,4

3,2

16,0

2,4

4,3

19,0

4,8

7,2

Cop.
weight
kg/km

Weight
approx.
kg/km

2,1 - 2,5

4,8

8,7

2,2 - 2,7

7,2

11,9

2,4 - 2,8

9,6

14,0

black

gn-ye

blue

brown

red

white

grey

vio

dk-bu

29500
29509
29518
-

29501
29510
29519
-

29502
29511
29520
-

29503
29512
29521
-

29504
29513
29522
-

29505
29514
29523
-

29506
29515
29524
-

29507
29516
29525
-

29508
29517
29526
-

AWG-No.
black

AWG-No.
gn-ye

AWG-No.
blue

AWG-No.
brown

AWG-No.
red

AWG-No.
white

AWG-No.
grey

AWG-No.
vio

AWG-No.
dk-bu

29942
20
29951
18
29960
17

29943
20
29952
18
29961
17

29944
20
29953
18
29962
17

29945
20
29954
18
29963
17

29946
20
29955
18
29964
17

29947
20
29956
18
29965
17

29948
20
29957
18
29966
17

29949
20
29958
18
29967
17

29950
20
29959
18
29968
17

H05 V2-K 90C


Cross-sec.
mm
Part no.
0,5
Part no.
0,75
Part no.
1

Core
min. - max.
mm

Dimensions and specifications may be changed without prior notice. (RK01)

K 19
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTHERM 125-J/-O

extra flexible, halogen-free, temperature resistant,

meter marking


Technical data

Cable structure

Properties

flexible and heat-resistant single core


Temperature range
Flexing -50 C to 125 C
Nominal voltage
U0/U 600/1000 V
Test voltage 4000 V
Minimum bending radius
flexing approx. 7,5x cable
fixed installationa approx.3x cable

Tinned copper, fine wire conductor, to DIN


VDE 0295 Kl.5, BS6360 cl.5 and/or
IEC60228 cl.5.
1st core insulation from special compound
elastomer based, cross-linked, colour: black
or green/yellow
2nd core insulation from compound
elastomer based, cross-linked, colour: black
meter marking


Halogen-free
uv-resistant
Abrasion resistant
Flexible at heat and low temperature
The materials used in manufacture are
silicon and cadmium-free and contain no
substances harmful to the wetting
properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).

Application
These halogen-free and temperature resistant single core are used for wiring up the heaters, electric machines (temperature class B),
switching systems and distribution switchboards, production lines and machinery production. The excellence temperature resistant is the
guarantee of a very long life cycle.
= roduct is conformed with the EC Low-Voltage Directive 2006/95/EG


HELUTHERM 125-J
Part no.
65300
65301
65302
65303
65304
65305
65306
65307
65308
65309
65310
65311
65312
65313

No.cores x
cross-sec.
mm
1G0,5
1G0,75
1G1
1G1,5
1G2,5
1G4
1G6
1G10
1G16
1G25
1G35
1G50
1G70
1G95

Outer
Cop.
approx. mm weight
kg/km
3,6
4,8
3,8
7,2
4,1
9,6
4,6
14,4
5,2
24,0
5,7
38,0
6,7
58,0
8,1
96,0
9,5
154,0
11,2
240,0
12,4
336,0
14,2
480,0
16,9
672,0
18,6
912,0

Weight
approx.
kg/km
13,0
16,0
20,0
27,0
37,0
52,0
76,0
121,0
182,0
267,0
363,0
526,0
700,0
1014,0

AWG-No.
20
18
17
16
14
12
10
8
6
4
2
1
2/0
3/0

HELUTHERM 125-O
Part no.
65286
65287
65288
65289
65290
65291
65292
65293
65294
65295
65296
65297
65298
65299

No.cores x
cross-sec.
mm
1x0,5
1x0,75
1x1
1x1,5
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95

Outer
Cop.
approx. mm weight
kg/km
3,6
4,8
3,8
7,2
4,1
9,6
4,6
14,4
5,2
24,0
5,7
38,0
6,7
58,0
8,1
96,0
9,5
154,0
11,2
240,0
12,4
336,0
14,2
480,0
16,9
672,0
18,6
912,0

Weight
approx.
kg/km
13,0
16,0
20,0
27,0
37,0
52,0
76,0
121,0
182,0
267,0
363,0
526,0
700,0
1014,0

AWG-No.
20
18
17
16
14
12
10
8
6
4
2
1
2/0
3/0

Dimensions and specifications may be changed without prior notice. (RN06)

K 20
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H07 V2-K

PVC single core, 90C, heat resistant

Technical data

Cable structure

Properties

Special PVC single core with increased


heat-resistance up to 90 C according to
DINVDE0281 part7 and HD21.7S2
Temperature range
flexing +5 C to +90 C
Nominal voltage U0/U 450/750 V
Test voltage 2000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
approx. 10-15x core
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Plain copper, fine wire, acc. to


DINVDE0295, cl.5, IEC60228 cl.5, BS6360
cl.5 and HD383
Special heat-resistant core insulation TI3 to
DINVDE0281 part7
Cores colour coded or on request
numbered according to DINVDE0293

Heat-resistant special PVC compound of


selected stabilizer and plasticizer
All requirements and test methods
conform DINVDE0281 part7
Not to be used in contact with objects
higher than 85 C
Only suitable for fixed protected installation
in, or on, lighting or controlgear for
voltages up to 1000Va.c. or, up to
750Vd.c. to earth
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.


Application
Therm insulated wires are ideal for use in power current installation, switch cabinets, motors and transformers which are subject to direct
contact with high temperatures (e.g. varnishing machines and drying towers etc.). These are also suitable for inside wiring of electrical
equipments such as lighting and heating apparatus.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Cross-sec.
mm
Part no.
1,5
Part no.
2,5
Part no.
4
Part no.
6
Part no.
10
Part no.
16
Part no.
25
Part no.
35
Part no.
50
Part no.
70
Part no.
95
Part no.
120
Part no.
150
Part no.
185
Part no.
240

Core
min. - max.
mm

Cop.
weight
kg/km

Weight
approx.
kg/km

2,8 - 3,4

14,4

20,0

3,4 - 4,1

24,0

33,3

3,9 - 4,8

38,0

48,3

4,4 - 5,3

58,0

68,5

5,7 - 6,8

96,0

115,0

6,7 - 8,1

154,0

170,0

8,4 - 10,2

240,0

270,0

9,7 - 11,7

336,0

367,0

11,5 - 13,9

480,0

520,0

13,2 - 16,0

672,0

729,0

15,1 - 18,2

912,0

962,0

16,7 - 20,2

1115,0

1235,0

18,6 - 22,5

1440,0

1523,0

20,6 - 24,9

1776,0

1850,0

23,5 - 28,4

2304,0

2430,0

black

gn-ye

blue

brown

red

white

grey

vio

dk-bu

29970
29979
29988
29997
30006
30015
30024
30033
30042
30051
30060
30069
30078
30087
30096
-

29971
29980
29989
29998
30007
30016
30025
30034
30043
30052
30061
30070
30079
30088
30097
-

29972
29981
29990
29999
30008
30017
30026
30035
30044
30053
30062
30071
30080
30089
30098
-

29973
29982
29991
30000
30009
30018
30027
30036
30045
30054
30063
30072
30081
30090
30099
-

29974
29983
29992
30001
30010
30019
30028
30037
30046
30055
30064
30073
30082
30091
30100
-

29975
29984
29993
30002
30011
30020
30029
30038
30047
30056
30065
30074
30083
30092
30101
-

29976
29985
29994
30003
30012
30021
30030
30039
30048
30057
30066
30075
30084
30093
30102
-

29977
29986
29995
30004
30013
30022
30031
30040
30049
30058
30067
30076
30085
30094
30103
-

29978
29987
29996
30005
30014
30023
30032
30041
30050
30059
30068
30077
30086
30095
30104
-

Dimensions and specifications may be changed without prior notice. (RK01)

K 21
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTHERM 145

flexible, cross-linked, halogen-free

Technical data

Cable structure

Properties

Halogen-free single cores with increased


heat resistance
Temperature range
flexing -35 C to +120 C
fixed installation -55 C to +145 C
Nominal voltage
U0/U 300/500 V up to 1 mm
U0/U 450/ 750 V from 1,5 mm
for fixed and protected installation
U0/U 600/1000 V from 1,5 mm
Test voltage 3500 V
Minimum bending radius
flexing 12,5x cable
fixed installation 4x cable
Caloric load values
see Technical Informations
Power ratings table
see Technical Informations
Approval
Germanischer Lloyd

Tinned Cu wires, according to DINVDE0295


cl.5, BS6360 cl.5 and IEC60228 cl.5
Core insulation of polyolefin-copolymer,
cross-linked
Core colours see table
Tests
Flame test (unit flame test) to VDE
0482-332-3, BS 4066 part 3/ DIN EN
60332-3-22, IEC 60332-3-22 (equivalent DIN
VDE 0472 part 804 test method C)
Flame test (cable) to VDE 0482-332-1-2,
DIN EN 60332-1-2, IEC 60332-1-2
(equivalent DIN VDE 0472 part 804 test
method B)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Halogen-free according to VDE0482
part267/ DINEN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density to VDE0482 part268-1
and2, test methodC, IEC61034-1/61034-2,
HD606 and BS7622 part1 and2
(DINVDE0472 part816)

Lower propagation of fire


Low development of smoke and fumes
Good abrasion and notch resistance
Good resistance to oils and weathering
Resistant to UV radiation and ozone
Resistant to soldering temperatures
Thermal class B
These single-core cables are resistant to
melting, even when in contact with a
soldering iron at temperatures of between
300 C and 380 C, because of the
cross-linking for the insulation material
Due to the high temperature profile the
cross-section of conductor can under
certain circumstances be reduced, hereby
enabling a saving in space requirement and
weight
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Application
These temperature resistant single-core cables are used for the internal wiring of lighting fixtures, heaters, electrical machinery, switching
systems and distributors in equipment and plant and machinery, suitable for installation on, in and beneath plaster, in closed installation
ducts, as well as for traffic systems and outdoor applications. These cables are not approved for direct routing on racks, gutters or tanks.
For a protected installation, these cables may be used at a nominal voltage of up to 1000 V alternating current or a direct current up to 750
V when earthed. The maximum operating d.c. voltage used in rail vehicles shall not exceed 900 V when earthed. These halogen-free single
core cables are characterised by their amazingly high long-time resistance to temperature and feature among the leading halogen-free,
flame resistant products in the world. These single core cables significantly contribute to safety and the environment.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



CrossOuter
Cop.
section
min. - max. weight
mm
mm
kg/km
approx. RAL
Part no.
0,25
1,4 - 1,8
2,4
Part no.
0,33
1,5 - 1,9
3,2
Part no.
0,5
1,7 - 2,1
4,8
Part no.
0,75
2,0 - 2,4
7,2
Part no.
1
2,3 - 2,7
9,6
Part no.
1,5
2,7 - 3,1
14,4
Part no.
2,5
3,3 - 3,7
24,0
Part no.
4
4,1 - 4,5
38,0
Part no.
6
4,75 - 5,25
58,0
Part no.
10
6,0 - 6,6
96,0

Weight
approx.
kg/km
4,0
5,0
7,0
11,0
14,0
20,0
30,0
47,0
72,0
120,0

black

gn-ye

brown

red

white

grey

vio

dk-bu

ye

Beige

lt-bu

og

green

2-col.

50999
51167
51281
51295
51309
51323
51337
51351
51365
51379
-

50998
51166
51280
51294
51308
51322
51336
51350
51364
51378
-

51071
51169
51283
51297
51311
51325
51339
51353
51367
51381
-

51072
51170
51284
51298
51312
51326
51340
51354
51368
51382
-

51073
51171
51285
51299
51313
51327
51341
51355
51369
51383
-

51074
51172
51286
51300
51314
51328
51342
51356
51370
51384
-

51075
51173
51287
51301
51315
51329
51343
51357
51371
51385
-

51079
51177
51291
51305
51319
51333
51347
51361
51375
51389
-

51076
51174
51288
51302
51316
51330
51344
51358
51372
51386
-

51164
51178
51292
51306
51320
51334
51348
51362
51376
51390
-

51070
51168
51282
51296
51310
51324
51338
51352
51366
51380
-

51077
51175
51289
51303
51317
51331
51345
51359
51373
51387
-

51078
51176
51290
51304
51318
51332
51346
51360
51374
51388
-

51165
51179
51293
51307
51321
51335
51349
51363
51377
51391
-

Continuation

K 22
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTHERM 145

flexible, cross-linked, halogen-free


CrossOuter
section
min. - max.
mm
mm
approx. RAL
Part no.
16
7,25 - 7,75
Part no.
25
9,35 - 9,85
Part no.
35
10,3 - 11,1
Part no.
50
12,6 - 13,4
Part no.
70
14,7 - 15,4
Part no.
95
16,9 - 17,7
Part no.
120
18,2 - 19,2
Part no.
150
20,8 - 22,0
Part no.
185
23,0 - 24,2
Part no.
240
26,1 - 27,3

Cop.
weight
kg/km

Weight
approx.
kg/km

154,0

182,0

240,0

272,0

336,0

371,0

480,0

530,0

672,0

730,0

912,0

964,0

1152,0

1235,0

1440,0

1523,0

1776,0

1850,0

2304,0

2432,0

black

gn-ye

brown

red

white

grey

vio

dk-bu

ye

Beige

lt-bu

og

green

2-col.

51420
51434
51448
51462
51476
51490
51504
51518
51532
51546
-

51419
51433
51447
51461
51475
51489
51503
51517
51531
51545
-

51422
51436
51450
51464
51478
51492
51506
51520
51534
51548
-

51423
51437
51451
51465
51479
51493
51507
51521
51535
51549
-

51424
51438
51452
51466
51480
51494
51508
51522
51536
51550
-

51425
51439
51453
51467
51481
51495
51509
51523
51537
51551
-

51426
51440
51454
51468
51482
51496
51510
51524
51538
51552
-

51430
51444
51458
51472
51486
51500
51514
51528
51542
51556
-

51427
51441
51455
51469
51483
51497
51511
51525
51539
51553
-

51431
51445
51459
51473
51487
51501
51515
51529
51543
51557
-

51421
51435
51449
51463
51477
51491
51505
51519
51533
51547
-

51428
51442
51456
51470
51484
51498
51512
51526
51540
51554
-

51429
51443
51457
51471
51485
51499
51513
51527
51541
51555
-

51432
51446
51460
51474
51488
51502
51516
51530
51544
51558
-

Dimensions and specifications may be changed without prior notice. (RK01)

Drag Chain Systems


Open chains
Closed chains
Accessories
Installation instructions
Selection tables

You can nd drag chain systems in our catalogue Cable Accessories.

K 23
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SiF / SiFF

silicon single cores, halogen-free

Technical data

Cable structure

Spezial-silicon single core with higher


heat-resistance range adapted to
DINVDE0250 Teil1 and part502
Temperatue range
-60 C to +180 C
(up to +220 C for short time)
Temperature limit at the conductor
in operation +180 C
Nominal voltage U0/U 300/500 V
Test voltage 2000 V
Breakdown voltage min. 5000 V
Minimum bending radius
6x cable
Radiation resistance
up to 20 x 106 cJ/kg (up to 20 Mrad)

Type SiF
Tinned copper conductors
0,5 mm to DINVDE0295 Kl.5, BS6360 cl.5
and IEC60228 cl.5
for 0,25mm = 14x0,15mm
Silicone core insulation
Type SiFF
as SiF but with high flexible copper strands
(see content technical information)
Strand make-up
0,25 to 1,0mm - cl. 6 col. 7
(single wire 0,05mm)
1,5 to 10mm - cl.6 col.6
(single wire 0,07mm)

Properties

Advantages
High ignition or flash point
Resistant to
High molecular oils, fats from vegetables
and animals, alcohols, plasticizers and
clophenes, diluted acids, lyes and salt
dissolution, oxidation substances, tropical
influences and weather, lake water, oxygen
Halogen-free
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Behaviour in fire
no flame propagation
test according to VDE 0482-332-1-2, DIN
EN 60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
For laying as a fixed installation only in open
or ventilated pipe systems as well as in
ducts. Otherwise the mechanical properties
of the silicon are reduced by the enclosed
air at temperatures exceeding 90 C.


Note

Please complete the part number for these


cables by adding the suffix for the colour
required as per the list:
00 = green, 01 = black, 02 = red,
03 = blue, 04 = brown, 05 = white,
06 = grey, 07 = violet, 08 = yellow,
09 = orange, 10 = transparent,
11 = pink, 12 = beige, 13 = twin colour


Application
Special cables for use in high, resp. low temperature areas. They are used mainly in the steel producing industries, in aviation industries as
well as in ship building, cement, glas and ceramic factories. As this cables are halogen-free, especially suited for use in power stations.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


SiF

Part no.

Cross-sec.
mm

232xx
233xx
234xx
235xx
236xx
237xx
238xx
239xx
246xx
247xx
248xx

0,25
0,5
0,75
1
1,5
2,5
4
6
10
16
25

Outer
Cop.
approx. mm weight
kg/km
1,9
2,4
2,1
4,8
2,4
7,2
2,5
9,6
2,8
14,4
3,4
24,0
4,2
38,0
5,0
58,0
6,6
96,0
7,4
154,0
9,2
240,0

Weight
approx.
kg/km
5,5
8,6
11,8
13,5
18,5
30,0
47,3
71,1
119,4
187,7
289,6

AWG-No.

Outer
Cop.
approx. mm weight
kg/km
10,3
336,0
12,2
480,0
14,2
672,0
16,6
912,0
18,0
1152,0
20,0
1440,0
22,5
1776,0

Weight
approx.
kg/km
398,3
559,7
765,8
1031,5
1284,6
1563,4
1858,2

AWG-No.

24
20
18
17
16
14
12
10
8
6
4

SiFF
Part no.

Cross-sec.
mm

451xx
452xx
453xx
454xx
455xx
456xx
457xx
458xx
459xx

0,25
0,5
0,75
1
1,5
2,5
4
6
10

Outer
Cop.
approx. mm weight
kg/km
1,9
2,4
2,2
4,8
2,5
7,2
2,6
9,6
2,9
14,4
3,5
24,0
4,4
38,0
5,2
58,0
6,8
96,0

Weight
approx.
kg/km
6,0
10,0
13,0
15,0
19,0
32,0
50,0
73,0
125,0

AWG-No.
24
20
18
17
16
14
12
10
8

SiF (wire colour black)


Part no.

Cross-sec.
mm

23953
23954
23955
23956
23957
23958
23959

35
50
70
95
120
150
185

2
1
2/0
3/0
4/0
300 kcmil
350 kcmil

Dimensions and specifications may be changed without prior notice. (RK01)

K 24
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SiF/GL, SiD, SiD/GL

silicon single cores, halogen-free

Technical data

Cable structure

Properties

Spezial-silicon single core with higher


heat-resistance range adapted to
DINVDE0250 Teil1 and part502
Temperatue range
-60 C to +180 C
(up to +220 C for short time)
Temperature limit at the conductor
in operation +180 C
Nominal voltage U0/U 300/500 V
Test voltage 2000 V
Breakdown voltage min. 5000 V
Minimum bending radius
15x cable
(SID only for permanent installation)
Radiation resistance
up to 20 x 106 cJ/kg (up to 20 Mrad)

Type SiF/GL
Tinned copper conductors
0,5 mm to DINVDE0295 Kl.5, BS6360 cl.5
and IEC60228 cl.5
for 0,25mm = 14x0,15mm
Silicone core insulation
Glass-fibre braiding
Type SiD
solid tinned copper conductor silicone
isulated
Type SiD/GL
as SID but with an additional glass-fibre
braiding


Resistant to
High molecular oils, fats from vegetables
and animals, alcohols, plasticizers and
clophenes, diluted acids, lyes and salt
dissolution, oxidation substances, tropical
influences and weather, lake water, oxygen
Corrosivity of combustion gases
(Halogen-free)
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813

Behaviour in fire
no flame propagation, test according to
VDE 0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
High flash points
For laying as a fixed installation only in open
or ventilated pipe systems as well as in
ducts. Otherwise the mechanical properties
of the silicon are reduced by the enclosed
air at temperatures exceeding 90 C.


Note

Please complete the part number for these


cables by adding the suffix for the colour
required as per the list:
00 = green, 01 = black, 02 = red,
03 = blue, 04 = brown, 05 = white,
06 = grey, 07 = violet, 08 = yellow,
09 = orange, 10 = transparent,
11 = pink, 12 = beige, 13 = twin colour


Application
Special cables for use in high, resp. low temperature areas. They are used mainly in the steel producing industries, in aviation industries as
well as in ship building, cement, glas and ceramic factories. As this cables are halogen-free, especially suited for use in power stations.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


SiF/GL

Part no.

Cross-sec.
mm

47001
47002
47003
47004
47005
47006
47007
47008
47009
47010
47011
47012
47013

0,25
0,5
0,75
1
1,5
2,5
4
6
10
16
25
35
50

Outer
Cop.
approx. mm weight
kg/km
2,4
2,4
2,5
4,8
2,8
7,2
2,9
9,6
3,2
14,4
3,8
24,0
4,6
38,0
5,4
58,0
7,6
96,0
8,4
154,0
10,2
240,0
11,3
336,0
13,4
480,0

Weight
approx.
kg/km
7,7
12,4
16,2
18,2
23,4
35,2
53,5
77,4
129,2
198,4
303,0
413,2
577,8

AWG-No.
24
20
18
17
16
14
12
10
8
6
4
2
1

SiD
Part no.

Cross-sec.
mm

461xx
462xx
463xx
464xx
465xx
466xx
467xx
468xx
469xx

0,2
0,28
0,5
0,75
1
1,5
2,5
4
6

Outer
Cop.
approx. mm weight
kg/km
1,7
1,9
1,8
2,7
2,0
4,8
2,1
7,2
2,3
9,6
2,5
14,4
3,2
24,0
3,9
38,0
4,4
58,0

Weight
approx.
kg/km
4,2
5,1
7,5
10,2
12,6
18,1
28,7
45,2
64,3

AWG-No.

Outer
Cop.
approx. mm weight
kg/km
2,4
4,8
2,6
7,2
2,7
9,6
3,0
14,4
3,6
24,0
4,3
36,0
5,0
58,0

Weight
approx.
kg/km
10,0
15,0
19,0
28,0
40,0
55,0
80,0

AWG-No.

20
18
17
16
14
12
10

SiD/GL
Part no.

Cross-sec.
mm

47014
47015
47016
47017
47018
47019
47020

0,5
0,75
1
1,5
2,5
4
6

20
18
17
16
14
12
10

Dimensions and specifications may be changed without prior notice. (RK01)

K 25
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

FZ-LSi / FZ-LS / Neon Light Cables




Technical data

FZ-LSi, blue
Test voltage 20 kV
Breakdown voltage min. 30 kV
Ignition voltage (kV eff.)
0,5 mm = 6 kV
1,0 mm = 8 kV
1,5 mm = 10 kV
FZ-LS, red
Test voltage
for 5 mm = 15 kV
for 7 mm = 20 kV
Breakdown voltage
for 5 mm : min. 25 kV
for 7 mm : min. 35 kV
Neon-light-Cable, yellow
Nominal voltage
3,5 kV, 4,0 kV bzw. 7,5 kV
Test voltage 10 kV
Specific volume resistivity
min. 1012 Ohm x cm
Minimum bending radius
approx. 7,5x cable
Radiation resistance
up to 20x106 cJ/kg (up to 20 Mrad)

Cable structure

FZ-LSi, blue
Tinned copper stranded conductor, strand
make-up see table below
Silicone core insulation 2GI1 to
DINVDE0207 part20
Glass-fibre braiding
Outer-jacket silicone 2GM1 to DINVDE0207
part21
Jacket colour blue
FZ-LS, red
Tinned copper conductor, 19x0,25mm
Silicone core insulation 2GI1 to
DINVDE0207 part20
Jacket colour redbrown
Neon-light-cable, yellow
in adapted to DINVDE0250 part1 and
part5
Tinned copper stranded conductor
30x0,25mm
Silicon core insulation 2GI1 to DINVDE0207
part20
Jacket colour yellow

Properties

Neon-light-cable, yellow
Halogen-free according to VDE0482
part267/ DINEN50267-2-2/ IEC60754-2
(equivalent DINVDE0472 part813)
No flame propagation according to
DINVDE0482 part265-2-1/ EN50265-2-1/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
No formation of corrosive gases
Low smoke density
Very good weather resistance


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application
FZ-LSi, blue
This ignition cable is suitable for use at high and extremely alternating ambient temperatures up to +180 C. Applications include engine
manufacturing, valve manufacturing and heating technology. As protection against mechanical damages a glass fibre braiding and a silicone
sheath covers the core insulation.
FZ-LS, red
This ignition cable is suitable for use at high and extremely alternating ambient temperatures up to +180 C. Applications include the lamp
and lighting industry and cooling and airconditioning technology.
Neon-light-cable, yellow
This cable is primarily suitable for use at high and extremely alternating ambient temperatures such as in the lamp and lighting industry.
Protected installation is required.


FZ-LSi ignition cable


Part
no.

Core
colour

23110
23106
23107

blue
blue
blue

Cross- Cond.
Outer Cop.
Weight
section make-up
approx. weight approx.
mm (nom. val.) mm
kg/km kg/km
n x wire
0,5
7 x 0,3
5,0
4,8
36,0
1
19 x 0,25
7,5
9,5
65,0
1,5
28 x 0,26
8,5
14,4
88,0

AWG-No.

20
17
16

FZ-LS high-voltage ignition cable 15 and 20kV


Part
no.
23109
23108

Core
colour

Cross- Cond.
Outer Cop.
Weight
section make-up
approx. weight approx.
mm (nom. val.) mm
kg/km kg/km
n x wire
red-brown
1
19 x 0,25
5,0
9,6
34,0
red-brown
1
19 x 0,25
7,0
9,6
60,0

AWG-No.

17
17

neon light cables (neon cable) 3,5kV, 4,0kV and 7,5kV


Part
no.

Core
colour

23147
23148
23149

ye
ye
ye

Cross- Cond.
Outer Cop.
Weight
section make-up
approx. weight approx.
mm (nom. val.) mm
kg/km kg/km
n x wire
1,5
30 x 0,25
4,4
14,4
32,0
1,5
30 x 0,25
6,6
14,4
59,0
1,5
30 x 0,25
7,6
14,4
75,0

AWG-No.

16
16
16

Dimensions and specifications may be changed without prior notice. (RK01)

K 26
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUFLON-FEP-6Y fluorinated polymeric materials, single core,


-100C to +205C


Technical data

Cable structure

Properties

Fluorinated polymeric insulation FEP


(Fluorethylenepropylene)
Temperature range
-100 C to +205 C
(up to +230 C for short time)
Nominal voltage 600 V
Test voltage 2500 V
Insulation resistance
min. 2 GOhm x km
Minimum bending radius
flexing 10x cable
fixed installation 4x cable
Radiation resistance
up to 1x106 cJ/kg (up to 1 Mrad)
Conductor temperature range
plain copper +130 C
tinned copper +180 C
silver pl. copper +200 C

Stranded copper wire, bare, tinned, silver


Make-up fine wire stranded to
DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation FEP-HELUFLON

Higher insulation resistance


Low dielectric loss
Not flammable
Min. 20 kV dielectric strength
Resistant to micro-cultures
Do not permit any fungus-formation
Absolute ozone resistant
Absolute weather resistant
Water absorption <0,01%
Minimal water vapour permeability (approx.
0,18 mgr/cm in 24 hours)
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
Please complete the above part-no. for the
colour required using the following table:
1 = black, 2 = red, 3 = blue,
4 = brown, 5 = white, 6 = transparent,
7 = twintone, 8 = other colours


Application
Teflon cables are predominantly used for installing in control cabinets subjected to high thermal effects as well as in brickworks, heaters,
kitchen fitments and measuring appliances as well as in the chemical industry. These cables are non-flammable and resistant to acids, alkalis,
solvents, oil and petrol.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Copper wire, tinned


Part no.
2551x
2552x
2553x
2554x
2555x
2556x
2557x
2558x
2559x
2560x
2561x

No.cores x
cross-sec.
mm
1x0,14
1x0,25
1x0,5
1x0,75
1x1
1x1,5
1x2,5
1x4
1x6
1x10
1x16

Outer
approx. mm
1,0
1,16
1,42
1,62
1,9
2,2
2,65
3,2
4,4
5,3
8,0

Cop.
weight
kg/km
1,35
2,4
4,8
7,2
9,6
14,4
24,0
38,0
58,0
96,0
154,0

Weight
approx.
kg/km
2,6
4,1
8,0
9,7
12,7
17,9
26,4
43,1
65,9
115,0
175,0

AWG-No.

Cop.
weight
kg/km
1,35
2,4
4,8
7,2
9,6
14,4

Weight
approx.
kg/km
2,6
4,1
8,0
9,7
12,7
17,9

AWG-No.

26
24
20
18
17
16
14
12
10
8
6

Copper wire, bare


Part no.
2490_
2491_
2492_
2493_
2494_
2495_

No.cores x
cross-sec.
mm
1x0,14
1x0,25
1x0,5
1x0,75
1x1
1x1,5

Outer
approx. mm
1,0
1,16
1,42
1,62
1,9
2,2

26
24
20
18
17
16

Copper wire, bare


Part no.
2496_
2497_
2498_
2499_
2037_

No.cores x
cross-sec.
mm
1x2,5
1x4
1x6
1x10
1x16

Outer
approx. mm
2,65
3,2
4,4
5,3
8,0

Cop.
weight
kg/km
24,0
38,0
58,0
96,0
154,0

Weight
approx.
kg/km
26,4
43,1
65,9
115,0
175,0

AWG-No.

Cop.
weight
kg/km
1,35
2,4
4,8
7,2
9,6
14,4
24,0
38,0
58,0
96,0
154,0

Weight
approx.
kg/km
2,6
4,1
8,0
9,7
12,7
17,9
26,4
43,1
65,9
115,0
175,0

AWG-No.

14
12
10
8
6

copper wires, silvered


Part no.
2026_
2027_
2028_
2029_
2030_
2031_
2032_
2033_
2034_
2035_
2036_

No.cores x
cross-sec.
mm
1x0,14
1x0,25
1x0,5
1x0,75
1x1
1x1,5
1x2,5
1x4
1x6
1x10
1x16

Outer
approx. mm
1,0
1,16
1,42
1,62
1,9
2,2
2,65
3,2
4,4
5,3
8,0

26
24
20
18
17
16
14
12
10
8
6

Dimensions and specifications may be changed without prior notice. (RK01)

K 27
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUFLON-PTFE-5Y fluorinated polymeric materials, single core, 600V / 1000V




Technical data

Cable structure

Properties

Fluorinated polymeric insulation PTFE


(Polytetrafluorethylene)
Design to DIN VDE 0881 an IEC 60673
Temperature range
-190 C to +260 C
(up to +300 C for short time)
Nominal voltage
type E = 600 V
type EE = 1000 V
Test voltage
type E = 3,4 kV
type EE = 5 kV
Insulation resistance
min. 1 GOhm x km
Minimum bending radius
10x cable
Radiation resistance
up to 1x105 cJ/kg (up to 1 Mrad)
Conductor temperature range
plain copper +130 C
tinned copper +180 C
silver pl. copper +200 C
nickel pl. copper +300 C

Stranded copper wire, silver. Bare, tinnedor


nickel-plated on request
Core insulation PTFE-HELUFLON to
DINVDE207 part6
Cores colour coded
Outer jacket PTFE-HELUFLON
PTFE as per MIL-W 16878

Higher insulation resistance


Low dielectric loss
Not flammable
Resistant to micro-cultures
Do not permit any fungus-formation
Absolute ozone resistant
Absolute weather resistant
Water absorption <0,01%
Minimal water vapour permeability (approx.
0,18 mgr/cm in 24 hours)
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
Please complete the above part-no. for the
colour required using the following table:
1 = black, 2 = red, 3 = blue,
4 = brown, 5 = white, 6 = transparent,
7 = twintone, 8 = other colour
Conductor bare, tinned or nickel plated on
request

Application
Teflon cables are predominantly used for installing in control cabinets subjected to high thermal effects as well as in brickworks, heaters,
kitchen fitments and measuring appliances as well as in the chemical industry. These cables are non-flammable and resistant to acids, alkalis,
solvents, oil and petrol.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


600V

Part no. AWG-No. Cross-sec.


mm
2511x
2512x
2513x
2514x
2515x
2516x
2517x
2518x
2519x
2520x
2521x
2522x
2523x
2524x
2525x

32
30
28
26
26
24
24
22
22
20
20
18
18
16
14

0,03
0,06
0,09
0,14
0,14
0,21
0,24
0,35
0,38
0,57
0,57
0,90
0,95
1,23
1,94

Outer Cop.
approx. weight
mm
kg/km
0,74
0,4
0,81
0,6
0,89
0,9
0,99
1,4
0,99
1,4
1,12
2,3
1,12
2,3
1,27
3,5
1,27
3,5
1,47
5,6
1,47
6,1
1,74
9,6
1,74
9,6
2,04
13,5
2,40
18,0

Silv.
weight
kg/km
0,03
0,04
0,06
0,07
0,09
0,07
0,13
0,10
0,17
0,12
0,18
0,22
0,27
0,29
0,38

Weight
approx.
kg/km
0,38
0,59
0,93
1,47
1,58
2,31
2,52
3,68
3,99
6,0
6,4
9,45
10,2
12,9
20,3

1000V
Part no. AWG-No. Cross-sec.
mm
2531x
2532x
2533x
2534x
2535x
2536x
2537x
2538x
2539x
2540x
2541x
2542x
2543x
2544x
2545x

32
30
28
26
26
24
24
22
21
20
20
18
18
16
14

0,03
0,06
0,09
0,14
0,14
0,21
0,24
0,35
0,38
0,57
0,57
0,90
0,95
1,23
1,94

Outer Cop.
approx. weight
mm
kg/km
1,00
0,4
1,07
0,6
1,14
0,9
1,24
1,4
1,24
1,4
1,37
2,3
1,37
2,3
1,52
3,5
1,52
3,5
1,72
5,6
1,72
6,1
2,00
9,6
2,00
9,6
2,26
13,5
2,76
18,0

Silv.
weight
kg/km
0,03
0,04
0,06
0,07
0,09
0,07
0,13
0,10
0,17
0,12
0,18
0,22
0,27
0,29
0,38

Weight
approx.
kg/km
0,42
0,65
1,0
1,56
1,68
2,4
2,65
3,85
4,2
6,3
6,9
10,65
13,65
21,38
33,95

Dimensions and specifications may be changed without prior notice. (RK01)

K 28
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTHERM 400 Insulation class C




Technical data

Cable structure

Properties

Special core insulation


Mono or multi coloured
Temperature range
-60 C to +400 C
operating temperature
(up to +450 C for short time)
Nominal voltage 500 V
Test voltage 2000 V
Minimum bending radius
approx. 15x cable
Radiation resistance
up to 1x1010 cJ/kg (up to 1x104 Mrad)

Stranded nickel conductor


Overlapping with special heat-resistant
impregnation

These cables have very good electronic,


chemical and radiation resistant properties


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
Also available with additional Kapton film
at extra cost.

Application
The wide temperature range offered by this cable type makes it especially suited for use in the aviation and aerospace industries, for atomic
power stations and in the steel making and chemical industries.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Crosssection
mm
Part no.
0,5
Part no.
0,75
Part no.
1
Part no.
1,5
Part no.
2,5
Part no.
4
Part no.
6
Part no.
10
Part no.
16
Part no.
25
Part no.
35
Part no.
50
Part no.
70
Part no.
95
Part no.
120
Part no.
150
Part no.
185
Part no.
240

Conductor Outer
construction approx.
mm

Nickel
weight
kg/km

16 x 0,2

2,2

4,8

24 x 0,2

2,4

7,2

32 x 0,2

2,7

9,6

30 x 0,25

2,8

14,4

50 x 0,25

3,4

24,0

56 x 0,3

4,5

38,0

84 x 0,3

4,9

58,0

141 x 0,3

5,8

96,0

226 x 0,3

7,4

154,0

196 x 0,4

9,6

240,0

276 x 0,4

11,5

336,0

396 x 0,4

12,7

480,0

360 x 0,5

16,0

672,0

485 x 0,5

18,0

912,0

608 x 0,5

19,0

1152,0

756 x 0,5

22,0

1440,0

944 x 0,5

24,0

1776,0

1222 x 0,5

27,0

2304,0

black

gn-ye

blue

brown

red

white

grey

vio

ye

Beige

pink

og

2-col.

trans

50901
50915
50929
50943
50957
50971
50985
50890
51564
51578
51592
51606
51620
51634
51648
51662
51676
51690
-

50900
50914
50928
50942
50956
50970
50984
50209
51563
51577
51591
51605
51619
51633
51647
51661
51675
51689
-

50902
50916
50930
50944
50958
50972
50986
50891
51565
51579
51593
51607
51621
51635
51649
51663
51677
51691
-

50903
50917
50931
50945
50959
50973
50987
50892
51566
51580
51594
51608
51622
51636
51650
51664
51678
51692
-

50904
50918
50932
50946
50960
50974
50988
50893
51567
51581
51595
51609
51623
51637
51651
51665
51679
51693
-

50905
50919
50933
50947
50961
50975
50989
50894
51568
51582
51596
51610
51624
51638
51652
51666
51680
51694
-

50906
50920
50934
50948
50962
50976
50990
50895
51569
51583
51597
51611
51625
51639
51653
51667
51681
51695
-

50907
50921
50935
50949
50963
50977
50991
50896
51570
51584
51598
51612
51626
51640
51654
51668
51682
51696
-

50908
50922
50936
50950
50964
50978
50992
50897
51571
51585
51599
51613
51627
51641
51655
51669
51683
51697
-

50912
50926
50940
50954
50968
50982
50996
51561
51575
51589
51603
51617
51631
51645
51659
51673
51687
51701
-

50911
50925
50939
50953
50967
50981
50995
51560
51574
51588
51602
51616
51630
51644
51658
51672
51686
51700
-

50909
50923
50937
50951
50965
50979
50993
50898
51572
51586
51600
51614
51628
51642
51656
51670
51684
51698
-

50913
50927
50941
50955
50969
50983
50997
51562
51576
51590
51604
51618
51632
51646
51660
51674
51688
51702
-

50910
50924
50938
50952
50966
50980
50994
51559
51573
51587
51601
51615
51629
51643
51657
51671
51685
51699
-

Dimensions and specifications may be changed without prior notice. (RK01)

K 29
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTHERM 600 / 600-ES halogen-free / high-grade steel braiding




Technical data

Cable structure

Properties

Special core insulation for high


temperatures
Temperature range
-60 C to +600 C
Permissible temperature
+400 C to +600 C
(up to +600 C for short time)
Nominal voltage 500 V
Test voltage 2500 V
Minimum bending radius
approx. 5x cable

HELUTHERM 600
Stranded nickel conductor (ASTM B 355)
Double-insulated glass-fibre braiding,
impregnated with silicone
Braiding of special mineral fibres and
additional impregnation with silicone
HELUTHERM 600-ES
As per above
Additional braided high-grade steel,
coverage approx. 80%


Asbestos and cadmium-free




Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application

HELUTHERM 600 cables are used in applications where extremely high connecting and ambient temperatures occur, e.g. in iron and steel
works, rolling mills, foundries, glass and ceramic plants, in power construction as well as for wiring resistances in electrical heating equipment,
furnaces and in thermoplastic forming. Good characteristics in the presence of moisture and chemical effects.
HELUTHERM 600-ES
The robust braiding of high-grade steel protects the cable from aggressive atmospheres and mechanical stresses. The high-grade braiding
also gives this cable an attractive appearance. The braided screen can also be used for earthing purposes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


HELUTHERM 600
Part no.

51703
51704
51705
51706
51707
51708
51709
51710
51711
51712
51713
51714
51715

No.cores x
cross-sec.
mm
1 x 0,25
1 x 0,5
1 x 0,75
1x1
1 x 1,5
1 x 2,5
1x4
1x6
1 x 10
1 x 16
1 x 25
1 x 35
1 x 50

Conductor
construction
4 x 0,3
7 x 0,3
11 x 0,3
14 x 0,3
21 x 0,3
35 x 0,3
56 x 0,3
84 x 0,3
140 x 0,3
228 x 0,3
354 x 0,3
495 x 0,3
707 x 0,3

Outer
approx. mm
2,0
2,3
2,6
2,8
3,2
3,7
4,5
6,0
8,0
9,1
10,8
13,0
13,5

Linear
resistance
at 20C
Ohm / km

Max. permiss.
current carrying
capacity
at +400C (A)
1,5
2,5
4,5
5,5
7
10
13,5
16
21
28
36
58
70

Nickel
weight
kg/km

Linear
resistance
at 20C
Ohm / km

Max. permiss.
current carrying
capacity
at +400C (A)
2,5
4,5
5,5
7
10
13,5
16
21
28
36
58
70

Nickel
weight
kg/km

346
175
115
88
59
35
22
14,6
8,8
5,5
3,5
2,5
1,5

2,4
4,8
7,2
9,6
14,4
24,0
38,0
58,0
96,0
154,0
240,0
336,0
480,0

Weight
approx.
kg/km

AWG-No.

9,5
11,5
15,0
17,8
24,0
36,0
54,5
77,0
150,0
225,0
340,0
440,0
600,0

24
20
18
17
16
14
12
10
8
6
4
2
1

HELUTHERM 600-ES
Part no.

50475
50476
50477
50478
50479
50480
50481
50482
50483
50484
50485
50486

No.cores x
cross-sec.
mm
1 x 0,5
1 x 0,75
1x1
1 x 1,5
1 x 2,5
1x4
1x6
1 x 10
1 x 16
1 x 25
1 x 35
1 x 50

Conductor
construction
7 x 0,3
11 x 0,3
14 x 0,3
21 x 0,3
35 x 0,3
56 x 0,3
84 x 0,3
140 x 0,3
228 x 0,3
354 x 0,3
495 x 0,3
707 x 0,3

Outer
approx. mm
3,2
3,5
3,7
4,1
4,6
5,4
6,9
8,9
10,0
11,7
15,1
15,6

175
115
88
59
35
22
14,6
8,8
5,5
3,5
2,5
1,5

4,8
7,2
9,6
14,4
24,0
38,0
58,0
96,0
154,0
240,0
336,0
480,0

Weight
approx.
kg/km
21,0
29,0
38,0
44,0
56,0
78,0
112,0
198,0
281,0
410,0
536,0
697,0

AWG-No.

20
18
17
16
14
12
10
8
6
4
2
1

Dimensions and specifications may be changed without prior notice. (RK01)

K 30
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTHERM 800 / 800-ES halogen-free / high-grade steel braiding




Technical data

Cable structure

Properties

Special core insulation for high


temperatures
Temperature range
-120 C to +750 C
Permissible temperature
+600 C to +800 C
(up to +1200 C for short time)
Nominal voltage 500 V
Test voltage 2000 V
Minimum bending radius
approx. 5x cable

HELUTHERM 800
Stranded nickel conductor
Double-insulated glass-fibre braiding,
impregnated with silicone
Braiding of special mineral fibres and
additional impregnation with silicone
HELUTHERM 800-ES
As per above
Additional braided high-grade steel,
coverage approx. 80%

Asbestos and cadmium-free




Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application
HELUTHERM 800 cables are used in applications where extremely high connecting and ambient temperatures occur, e.g. in iron and steel
works, rolling mills, foundries, glass and ceramic plants, in power construction as well as for wiring resistances in electrical heating equipment,
furnaces and in thermoplastic forming. Good characteristics in the presence of moisture and chemical effects.
HELUTHERM 800-ES
The robust braiding of high-grade steel protects the cable from aggressive atmospheres and mechanical stresses. The high-grade braiding
also gives this cable an attractive appearance. The braided screen can also be used for earthing purposes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


HELUTHERM 800
Part no.

51716
51717
51718
51719
51720
51721
51722
51723
51724
51725
51726
51727
51728

No.cores x
cross-sec.
mm
1 x 0,25
1 x 0,5
1 x 0,75
1x1
1 x 1,5
1 x 2,5
1x4
1x6
1 x 10
1 x 16
1 x 25
1 x 35
1 x 50

Conductor
construction
4 x 0,3
7 x 0,3
11 x 0,3
14 x 0,3
21 x 0,3
35 x 0,3
56 x 0,3
84 x 0,3
140 x 0,3
228 x 0,3
354 x 0,3
495 x 0,3
707 x 0,3

Outer
approx. mm
2,2
2,3
2,9
3,2
3,2
3,7
4,5
5,9
8,0
9,0
10,6
13,4
14,0

Linear
resistance
at 20C
Ohm / km

Max. permiss.
current carrying
capacity
at +700C (A)
1
2
3
4
5
7
9
12
14
20
24
40
48

Nickel
weight
kg/km

Linear
resistance
at 20C
Ohm / km

Max. permiss.
current carrying
capacity
at +700C (A)
2
3
4
5
7
9
12
14
20
24
40
48

Nickel
weight
kg/km

346
175
115
88
59
35
22
14,6
8,8
5,5
3,5
2,5
1,5

2,4
4,8
7,2
9,6
14,4
24,0
38,0
58,0
96,0
154,0
240,0
336,0
480,0

Weight
approx.
kg/km

AWG-No.

10,2
12,0
16,0
19,0
26,5
38,8
57,0
81,0
156,0
240,0
370,0
490,0
645,0

24
20
18
17
16
14
12
10
8
6
4
2
1

HELUTHERM 800-ES
Part no.

50488
50489
50490
50491
50492
50493
50494
50495
50496
50497
50498
50499

No.cores x
cross-sec.
mm
1 x 0,5
1 x 0,75
1x1
1 x 1,5
1 x 2,5
1x4
1x6
1 x 10
1 x 16
1 x 25
1 x 35
1 x 50

Conductor
construction
7 x 0,3
11 x 0,3
14 x 0,3
21 x 0,3
35 x 0,3
56 x 0,3
84 x 0,3
140 x 0,3
228 x 0,3
354 x 0,3
495 x 0,3
707 x 0,3

Outer
approx. mm
3,5
3,8
4,1
4,5
4,9
5,8
7,3
9,4
10,5
12,2
15,5
16,1

175
115
88
59
35
22
14,6
8,8
5,5
3,5
2,5
1,5

4,8
7,2
9,6
14,4
24,0
38,0
58,0
96,0
154,0
240,0
336,0
480,0

Weight
approx.
kg/km
23,0
31,0
40,0
47,0
59,0
82,0
118,0
209,0
298,0
452,0
592,0
650,0

AWG-No.

20
18
17
16
14
12
10
8
6
4
2
1

Dimensions and specifications may be changed without prior notice. (RK01)

K 31
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTHERM 1200 / 1200-ES halogen-free / high-grade steel braiding




Technical data

Cable structure

Properties

Special core insulation for high


temperatures
Temperature range
-170 C to +1000 C
Permissible temperature
+800 C to +1100 C
(up to +1400 C for short time)
Nominal voltage 500 V
Test voltage 2000 V
Minimum bending radius
approx. 5x cable

HELUTHERM 1200
Stranded nickel conductor
Double-insulated glass-fibre braiding,
impregnated with silicone
Braiding of special mineral fibres and
additional impregnation with silicone
HELUTHERM 1200-ES
As per above
Additional braided high-grade steel,
coverage approx. 80%

Asbestos and cadmium-free




Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application
HELUTHERM 1200 cables are used in applications, where extremely high connecting and ambient temperatures occur, e.g. in iron and
steel works, rolling mills, foundries, glass and ceramic plants, in furnace and power plant construction as well for wiring resistances in electrical
heating equipment, furnaces and in thermoplastic forming. Good characteristics in the presence of moisture and chemical effects.
HELUTHERM 1200-ES
The robust braiding of high-grade steel protects the cable from aggressive atmospheres and mechanical stresses. The high-grade braiding
also gives this cable an attractive appearance. The braided screen can also be used for earthing purposes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


HELUTHERM 1200
Part no.

51729
51730
51731
51732
51733
51734
51735
51736
51737
51738
51739
51740

No.cores x
cross-sec.
mm
1 x 0,5
1 x 0,75
1x1
1 x 1,5
1 x 2,5
1x4
1x6
1 x 10
1 x 16
1 x 25
1 x 35
1 x 50

Conductor
construction
7 x 0,3
11 x 0,3
14 x 0,3
21 x 0,3
35 x 0,3
56 x 0,3
84 x 0,3
140 x 0,3
228 x 0,3
354 x 0,3
495 x 0,3
707 x 0,3

Outer
approx. mm
2,3
2,6
2,8
3,2
3,7
4,5
5,9
8,0
9,0
10,6
13,6
14,5

Linear
resistance
at 20C
Ohm / km

Max. permiss.
current carrying
capacity
at +700C (A)
2
3
4
5
7
9
12
14
20
24
40
48

Nickel
weight
kg/km

Linear
resistance
at 20C
Ohm / km

Max. permiss.
current carrying
capacity
at +700C (A)
2
3
4
5
7
9
12
14
20
24
40
48

Nickel
weight
kg/km

175
115
88
59
35
22
14,6
8,8
5,5
3,5
2,5
1,5

4,8
7,2
9,6
14,4
24,0
38,0
58,0
96,0
154,0
240,0
336,0
480,0

Weight
approx.
kg/km

AWG-No.

12,3
16,1
19,8
27,5
39,8
58,0
83,0
160,0
244,0
376,0
495,0
654,0

20
18
17
16
14
12
10
8
6
4
2
1

HELUTHERM 1200-ES
Part no.

50635
50636
50637
50638
50639
50640
50641
50642
50643
50644
50645
50646

No.cores x
cross-sec.
mm
1 x 0,5
1 x 0,75
1x1
1 x 1,5
1 x 2,5
1x4
1x6
1 x 10
1 x 16
1 x 25
1 x 35
1 x 50

Conductor
construction
7 x 0,3
11 x 0,3
14 x 0,3
21 x 0,3
35 x 0,3
56 x 0,3
84 x 0,3
140 x 0,3
228 x 0,3
354 x 0,3
495 x 0,3
707 x 0,3

Outer
approx. mm
3,6
3,8
4,2
4,7
5,0
6,0
7,5
9,7
10,9
12,9
15,7
16,7

175
115
88
59
35
22
14,6
8,8
5,5
3,5
2,5
1,5

4,8
7,2
9,6
14,4
24,0
38,0
58,0
96,0
154,0
240,0
336,0
480,0

Weight
approx.
kg/km
26,0
34,0
42,0
53,0
64,0
87,0
120,0
218,0
314,0
453,0
593,0
760,0

AWG-No.

20
18
17
16
14
12
10
8
6
4
2
1

Dimensions and specifications may be changed without prior notice. (RK01)

K 32
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Earth Conductors ESUY and ESY




Technical data

Cable structure

Properties

ESUY (H00V-D)
Earthing cable of braid wires over core
strands in adapted to DINVDE0283 part3,
and EN61138
Conductor resistance at 20 C
according DINVDE0283 part3
Temperature range
-5 C to +70 C
Test voltage 2000 V
Spark test (during winding)
16 mm to 35 mm - 5000 V
50 mm to 70 mm - 6000 V
95 mm to 240 mm - 8000 V
Insulation resistance
min. 20 MOhm x km
Minimal bending radius
approx. 12x cable
ESY
Earthing cable in adapted to DINVDE0283
part3 and EN61138
for further technical datas from conductor
resistance - see above ESUY (H00V-D)

ESUY (H00V-D)
Bare copper, extra fine wire conductors,
high flexible
Braiding of bare copper wires over the
stranded copper conductor
PVC-jacket, transparent (glass clear),
compound type TM2 according
DINVDE0281 part1
ESY
Bare copper, fine wire conductors
Copper conductors of stranded wires
PVC-jacket, transparent (glass clear),
compound type TM2 according
DINVDE0281 part1

For these cable types no nominal voltages


are mentioned, as these are: only used for
earthing performances
For further requirements see European
Norm EN61230 and DINVDE0683 part100:
Live working - Portable equipment for
earthing and earthing


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application

ESUY (H00V-D)
ESY
These high flexible earth conductors are used for earthing of portable equipment and short-circuiting. These cables specially perform a
protective function in repair live working of high voltage power supply company as EVU, in railway systems, failing current equipment,
alternating current systems and in networks of transmission and distribution. Because of that these are designated as safety cables. These
earthing cables offer special characteristics with low weights, high flexibility to a wide temperature range and the behavior in high temperature.
The protective sheath over conductor assures the essential function for protection against the mechanical and chemical stresses.


Type ESUY (HOOV-D), high flexible


Part no.
28930
28931
28932
28933
28934
28935
28936
28937
28938
28939

Cross-sec.
mm
16
25
35
50
70
95
120
150
185
240

Cond. make-up
n x wire
4200 x 0,07
3192 x 0,1
4480 x 0,1
6383 x 0,1
8918 x 0,1
12100 x 0,1
15300 x 0,1
19152 x 0,1
23580 x 0,1
30600 x 0,1

Outer
approx. mm
8,3
9,5
11,2
13,2
15,6
17,4
19,8
23,4
26,6
30,2

Cop.
weight
kg/km
194,0
280,0
415,0
585,0
820,0
1090,0
1360,0
1650,0
2150,0
2750,0

Weight
approx. kg/km

Cop.
weight
kg/km
155,0
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0

Weight
approx. kg/km

230,0
335,0
475,0
670,0
905,0
1220,0
1505,0
1940,0
2390,0
3090,0

AWG-No.
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil

Type ESY, flexible


Part no.
28940
28941
28942
28943
28944
28945
28946
28947

Cross-sec.
mm
16
25
35
50
70
95
120
150

Cond. make-up
n x wire
525 x 0,2
798 x 0,2
1120 x 0,2
1617 x 0,2
2254 x 0,2
3087 x 0,2
3822 x 0,2
4802 x 0,2

Outer
approx. mm
8,4
9,8
11,4
13,8
16,4
18,2
20,1
23,0

185,0
270,0
390,0
575,0
810,0
1080,0
1320,0
1680,0

AWG-No.
6
4
2
1
2/0
3/0
4/0
300 kcmil

Dimensions and specifications may be changed without prior notice. (RK01)

K 33
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H01N2-D / -E 100 V, VDE approved, welding cable




Technical data

Cable structure

Properties

Harmonized welding cable with rubber


jacket, according to DINVDE0282 part6
or HD22.6S2
Conductor resistance
according to HD383 cl.6
Conductor resistance factor
at 20 C - see Technical Informations
Temperature range
flexing -25 C to +80 C
fixed installation -40 C to +80 C
Admissible working temperature
at conductor +85 C
Nominal voltage U0/U 100/100 V
Test voltage 1000 V

Plain copper conductors (on request tinned


conductor available), extra fine stranded
to DINVDE0295, BS6360, IEC60228 and
HD383
Separator over conductor
Neoprene outer jacket, chlorinated rubber
compound EM5
Outer sheath black
Without green-yellow marking

Test according to VDE 0482-332-1-2, DIN


EN 60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Oil resistant to DIN EN 60811-2-1
The cable also maintains its high flexibilty
under the effect of ozone, light, oxygen,
inert gas, oil or petrol


Note

No. wires = Gauiding value, the number of


individual wires are without obligation.

Application
For use between the welding generator and the hand-electrode and the workpiece. For use in the automobile industry, in shipbuilding, in
transport and conveyor systems, tool making machinery, welding robots etc. These cables retain their high flexibility even under influence
of ozone, light, oxygen, protective gases, oil and petrol. The robust construction makes these cables resistant to both to cold and the heat
as well as to flames. They are suitable for use in open spaces and in dry and damp conditions.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


H01N2-D: Cables with standard flexibility, bending radius: approx. 12 x Cable


Part no.
31001
31002
31003
31004
31005
31006
31007
31008
31030
31031
31009

No.cores x
cross-sec.
mm
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240

No.wires x
single wire
mm
320 x 0,2
512 x 0,2
800 x 0,2
1120 x 0,2
1600 x 0,2
2240 x 0,2
3024 x 0,2
614 x 0,5
765 x 0,5
944 x 0,5
1225 x 0,5

Sheat
Nominal value
mm
2
2
2
2
2,2
2,4
2,6
2,8
3
3,2
3,4

Outer
min. - max.
mm
7,7 - 9,7
8,8 - 11,0
10,1 - 12,7
11,4 - 14,2
13,2 - 16,5
15,3 - 19,2
17,1 - 21,4
19,2 - 24,0
21,2 - 26,4
23,1 - 28,9
25,0 - 29,5

Cop.
weight
kg/km

Weight
approx. kg/km
96,0
154,0
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0
1776,0
2304,0

135,0
205,0
302,0
420,0
586,0
798,0
1015,0
1310,0
1620,0
1916,0
2540,0

AWG-No.
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil

H01N2-E: Cables with extreme high flexibility, bending radius: approx. 10 x Cable
Part no.
31032
31033
31034
31035
31036
31037
31038
31039
31019
31020

No.cores x
cross-sec.
mm
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185

No.wires x
single wire
mm
566 x 0,15
903 x 0,15
1407 x 0,15
1974 x 0,15
2830 x 0,15
3952 x 0,15
5370 x 0,15
3819 x 0,2
4788 x 0,2
5852 x 0,2

Sheat
Nominal value
mm
1,2
1,2
1,2
1,2
1,5
1,5
1,8
1,8
1,8
1,8

Outer
min. - max.
mm
6,2 - 7,8
7,3 - 9,1
8,6 - 10,8
9,8 - 12,3
11,9 - 14,8
13,6 - 17,0
15,6 - 19,5
17,2 - 21,6
18,8 - 23,5
20,4 - 25,5

Cop.
weight
kg/km

Weight
approx. kg/km
96,0
154,0
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0
1776,0

119,0
181,0
270,0
363,0
528,0
716,0
1012,0
1190,0
1305,0
1511,0

AWG-No.
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil

Dimensions and specifications may be changed without prior notice. (RK01)

K 34
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NSGAFU 3kV Special Rubber-Insulated Cable, VDE approved, short-circuit up


to 1000V


Technical data

Cable structure

Special rubber-insulated single core cables


to DINVDE0250 part602
Temperature range
flexing -25 C to +80 C
fixed installation -40 C to +80 C
Permissible operating temperature
at conductor +90 C
Nominal voltage U0/U 1,8/3 kV
Max. permissible operating voltage
for three and one-phase alternating
current operation U0/U 2,1/3,6 kV, for
direct current operation U0/U 2,7/5,4 kV
Test voltage 6 kV
Minimum bending radius
5x cable

Tinned copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5 and
IEC60228 cl.5
EPR-insulation, compound type 3GI3 to
DINVDE0207 part20
Polychloroprene outer jacket oil resistant,
abrasion resistance
Colour black or red

Properties

Oil resistant
Test to DINVDE0473 part811-2-1
Behaviour in fire
Test according to VDE 0482-332-1-2, DIN
EN 60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Considered as being short-circuit safe and
inherently earth-fault-proof are those
operating materials and conducting
assemblies where because of suitable
measures and/or means applied, neither a
short circuit nor a short to ground is to be
expected under operating conditions which
are in accordance with those specified for
the intended application.


Note

Version in 6 kV available on request.




Application
Particularly suitable for protection against short circuits in laying and for inherently earth-fault-proof routing in rail vehicles and omnibuses.
Also suitable for laying in dry environments.


Part no.
38501
38502
38503
38504
38505
38506
38507
38508

No.cores x
cross-sec.
mm
1x1,5
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35

Outer
approx. mm
7,0
7,5
9,0
9,5
11,0
13,0
15,0
16,5

Cop.
weight
kg/km
14,4
24,0
38,0
58,0
96,0
154,0
240,0
336,0

Weight
approx.
kg/km
62,0
76,0
95,0
140,0
190,0
270,0
410,0
490,0

AWG-No.
16
14
12
10
8
6
4
2


Part no.
38509
38510
38511
38513
38514
38512
38515
38516

No.cores x
cross-sec.
mm
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300

Outer
approx. mm
18,0
20,5
24,0
28,0
31,0
26,0
34,5
38,0

Cop.
weight
kg/km
480,0
672,0
912,0
1152,0
1440,0
1776,0
2304,0
2880,0

Weight
approx.
kg/km
650,0
900,0
1200,0
1450,0
1800,0
2200,0
2650,0
3250,0

AWG-No.
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil

Dimensions and specifications may be changed without prior notice. (RK01)

K 35
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NSHXAF 3kV halogen-free Special Rubber-Insulated Cable, VDE approved,


short-circuit up to 1000V


Technical data

Cable structure

Properties

Special rubber core cable acc. to


EDINVDE0250 Teil606
Temperature range
flexing -25 C to +70 C
fixed installation -40 C to +90 C
Permissible operating temperature
at conductor +90 C
Nominal voltage U0/U 1,8/3 kV
Highest permissible operating voltage
in three-phase and one-phase
a.c. systems U0/U 2,1/3,6 kV
in d.c. systems U0/U 2,7/5,4 kV
Test voltage 6 kV
Minimum bending radius
flexing 10x cable
fixed 6x cable

Bare or tinnedcopper conductor, fine wire


to DINVDE0295 cl.5, BS6360 cl.5 and/or
IEC60228 cl.5
EPR-insulation, 3GI3 acc. to DINVDE0207
part20
Halogen-free, polymer sheath GM3 acc. to
DINVDE0207 part24
Colour black

Tests
Corrosiveness of corrosive gases acc. to
VDE0482, part267/ DINEN50267-2-2/
IEC607542 (as per DINVDE0472, part813)
Smoke density acc. to DINVDE0482,
part268 HD606, EN50268-1+2/
IEC61034-1+2, BS7622 part1+2 (as per
DINVDE0472, part816)
Oil resistant acc. to DINVDE0473
part811-2-1
Behaviour in fire: Test acc. to VDE
0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)

Application
Particularly suitable for protection against short circuits in laying and for inherently earth-fault-proof routing in rail vehicles and omnibuses.
Also suitable for laying in dry environments. In switching units and distributors, they are considered to be short circuit and inherently earth
proof to 1000 V. Note: Considered as being short-circuit safe and inherently earth-fault-proof are those operating materials and conducting
assemblies where because of suitable measures and/or means applied, neither a short circuit nor a short to ground is to be expected under
operating conditions which are in accordance with those specified for the intended application.



Part no.
38517
38518
38519
38520
38521
38522
38523
38524

No.cores x
cross-sec.
mm
1x1,5
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35

Outer
approx. mm
5,9
6,2
6,8
7,4
8,7
9,5
11,9
13,1

Cop.
weight
kg/km
14,4
24,0
38,0
58,0
96,0
154,0
240,0
336,0

Weight
approx.
kg/km
62,0
76,0
95,0
140,0
190,0
270,0
410,0
490,0

AWG-No.
16
14
12
10
8
6
4
2


Part no.
38525
38526
38527
38528
38529
38530
38531
38532

No.cores x
cross-sec.
mm
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300

Outer
approx. mm
14,5
16,3
19,2
21,0
22,8
24,8
27,1
30,3

Cop.
weight
kg/km
480,0
672,0
912,0
1152,0
1440,0
1776,0
2304,0
2880,0

Weight
approx.
kg/km
650,0
900,0
1200,0
1450,0
1800,0
2200,0
2650,0
3250,0

AWG-No.
1
4
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil

Dimensions and specifications may be changed without prior notice. (RK01)

K 36
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

KOMPOSPEED 600 / 600-C 0,6/1kV double-insulated,


halogen-free, special single cores for drag chains, EMC-preferred type


Technical data

Cable structure

Special drag chain single cores for high


mechanical stress, adapted to DINVDE0281
part3
Temperature range
flexing -30 C to +90 C
fixed installation -40 C to +100 C
zulssige Betriebstemperatur
am Leiter +90 C
Nominal voltage U0/U 600/1000 V
Test voltage 3000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
KOMPOSPEED 600
flexing installation 5x cores
fixed installation 3x cores
KOMPOSPEED 600-C
flexing installation 7,5x cores
fixed installation 4x cores

KOMPOSPEED 600
Tinned copper, extra fine wire conductors,
bunch stranded to DINVDE0295 cl.6,
col.4, BS6360 cl.6 and IEC60228 cl.6
1. Core insulation of special thermoplastic
polymer, natural coloured
2. Core insulation of special polyolefine,
black (RAL9005)
KOMPOSPEED 600-C
Structure as above up to 1. core insulation
Screen of tinned cu-braid, coverage
approx. 85%
2. core-insulation of special polyolefine,
black (RAL9005)


Properties
Very good oil resistant
Halogen free
Abrasion resistant
Resistant to
Hydrofluoric acid
Hydrochloric acid
Diluted sulfuric acid
Coolants
Microbes
UV-radiation
Weather
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application
The special single cores are used for permanent flexible applications in machineries, machine tools, composting appliances and
sewage-treatment plants, animal stalls and greenhouses and used for permanent flexible application for movable automated machinery
parts and multi-shift operation as well as in open air. These cables are installed for flexible use with free movements without tensile stress
or forced movements and suitable for application in drag chains. The selected tinned copper wire conductor and tinned copper wire braid
permit the installation in aggressive environments as well as hydrogen sulfide, ammonia and sulfur dioxide.
KOMPOSPEED 600-C These screened cables are particularly suitable for the interference-free trans mission in instrumentation and control
engineering applications (electromagnetic compatibility).
EMC = Electromagnetic compatibility.
For application as a protective core, the ends are to be identified with green-yellow shrink-on tubes.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


KOMPOSPEED 600
Part no.
60288
60289
60290
60291
60292
60293
60294
60295
60296
60297
60298

No.cores x
cross-sec.
mm
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185

Outer
Cop.
approx. mm weight
kg/km
6,5
58,0
8,4
96,0
9,5
154,0
11,2
240,0
13,0
336,0
15,4
480,0
17,2
672,0
20,0
912,0
21,0
1152,0
23,8
1440,0
26,2
1776,0

Weight
approx.
kg/km
83,0
132,0
188,0
281,0
404,0
531,0
729,0
1049,0
1220,0
1510,0
1932,0

AWG-No.
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil

KOMPOSPEED 600-C
Part no.
60216
60217
60218
60219
60220
60221
60222
60223
60224
60225
60226
62500

No.cores x
cross-sec.
mm
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240

Outer
Cop.
approx. mm weight
kg/km
7,3
71,0
9,1
122,0
10,1
180,0
12,2
282,0
14,2
386,0
17,0
535,0
19,2
750,0
21,8
1004,0
23,8
1260,0
26,0
1570,0
28,8
1911,0
34,0
2470,0

Weight
approx.
kg/km
101,0
168,0
217,0
342,0
468,0
584,0
822,0
1190,0
1400,0
1710,0
2021,0
2850,0

AWG-No.
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
6

Dimensions and specifications may be changed without prior notice. (RK01)

K 37
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTRAIN 3GKW
HELUTRAIN 4GKW
Photo: fotolia.com

Train Cable

K 38
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTRAIN 3GKW Train-Cable, robust special single core, halogen-free, 0,6/1kV,


meter marking


Technical data

Cable structure

Temperature resistant special-insulated


wire
Temperature range
flexing -35 C to +90 C
fixed installation -45 C to +120 C
Short-circuit temperature
+250 C
Nominal voltage
U0/U 0,6/1 kV (AC)
U0/U 0,9/1,8 kV (DC)
Test voltage
3,5 kV
Minimum bending radius
fixed installation for cable
to 10 mm 3 xcable
> 10 mm 4 xcable 
flexing for cable
to 10 mm 5 xcable
> 10 mm 6 xcable

Tinned copper, fine wire conductors,


conform to DINVDE0295 cl.5 and
IEC60228 cl.5
Core insulationfrom Polyolefin
Copyolymer, cross-linked 
Colour grey or green-yellow

Properties

Tests
Flame test to VDE 0482part 266-2, BS
4066part 3/ DIN EN 50266-2/ IEC
60332-3 (conforms toDIN VDE 0472 Teil
804test methodC)
Flame retardant to DIN VDE
0482-331-1-2, DIN EN 60332-1-2, IEC
60332-1
Corrosiveness of combustion gases to
VDE 0482part 267/ DIN EN 50267-2-2/ IEC
60754-2 (conforms toDIN VDE 0472part
813)
Halogen-free to VDE 0482 part 267/ DIN
EN 50267-2-1/ IEC 60754-1 (conforms to
DIN VDE 0472 part 815)
Smoke density to VDE 0482 part 268-1
u. 2,test methodC, IEC
61034-1/61034-2, HD 606and BS 7622 part
1 and 2 (conforms toDIN VDE 0472part
816)
Oil- and gasoline resistant to
EN 50305
Ozon resistant to EN 50305
Low fire load (DIN 51900)
No fluor (EN 60684-2)
Resistant to mechanical influences in rough
environmental conditions
Good chemical durability with simultaneous
high fire safety
Reduction of toxic combustion gases and
the spread of the fire source in case of fire
increases protection against personal injury
and property damage
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Application
HELUTRAIN 3 GKW train cable areHalogen-free and suitable for fixed and protected installation inrough environmental conditions inside
and outside of rail vehicles. For connecting fixed and moving parts. Due to the flexibility and the small outer diameter suitable for fixed
installation in small bending radii.
=The product conforms to the EG Low-Voltage Directive 2006/95/EG.


Core colour grey


Part no.
59114
59115
59116
59117
59118
59119
59126
59127
59128
59129
59130
59131
59132
59133
59134
59135

No.cores x
cross-sec.
mm
1x0,5
1x0,75
1x1
1x1,5
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150

Outer
approx. mm
2,0
2,2
2,4
2,7
3,4
3,9
4,6
5,5
7,1
8,6
9,8
12,0
14,2
15,6
17,6
20,3

Cop.
weight
kg/km
4,8
7,2
9,6
14,4
24,0
38,4
57,6
96,0
154,0
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0

Weight
approx.
kg/km
9,0
12,0
14,0
21,0
31,0
46,0
68,0
111,0
166,0
250,0
350,0
500,0
690,0
940,0
1180,0
1460,0

AWG-No.

Core colour green-yellow


Part no.

53762
53763
53764
53765
53766
53767
53768
53769
53770
53771
53772
53773
53774
53775
53776
53777

No.cores x
cross-sec.
mm
1x0,5
1x0,75
1x1
1x1,5
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150

Outer
approx. mm
2,0
2,2
2,4
2,7
3,4
3,9
4,6
5,5
7,1
8,6
9,8
12,0
14,2
15,6
17,6
20,3

Cop.
weight
kg/km
4,8
7,2
9,6
14,4
24,0
38,4
57,6
96,0
154,0
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0

Weight
approx.
kg/km
9,0
12,0
14,0
21,0
31,0
46,0
68,0
111,0
166,0
250,0
350,0
500,0
690,0
940,0
1180,0
1460,0

AWG-No.
-

Dimensions and specifications may be changed without prior notice. (RK01)

K 39
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTRAIN 4GKW-AXplus Train-Cable, robust special single core,


halogen-free, 1,8/3kV, meter marking


Technical data

Temperature range
Fixed installation: -60 C to +120 C
Flexing: -35 C to +90 C
Short circuit: +200 C
Nominal voltage
U0/U AC 1,8/3 kV
U0/U DC 2,7kV
Test voltage
6,5 kV AC
Minimum bending radius
< 10 mm fixed installation > 5 x D
flexing > 7 x D
> 10 mm fixed installation > 6 x D
flexing > 8 x D

Cable structure

Properties

Tinned copper conductor, fine wire


stranded according to
DIN VDE 0295 cl. 5, BS 6360 cl. 5 or IEC
60228 cl. 5
Core insulation of crosslinked polyolefin
copolymer
Outer jacket cross linked Elastomer
Jacket colour: black

Tests
Flame test to VDE 0482part 266-2, BS
4066part 3/ DIN EN 50266-2/ IEC
60332-3 (conforms toDIN VDE 0472 Teil
804test methodC)
Flame retardant to DIN VDE
0482-331-1-2, DIN EN 60332-1-2, IEC
60332-1
Corrosiveness of combustion gases to
VDE 0482part 267/ DIN EN 50267-2-2/ IEC
60754-2 (conforms toDIN VDE 0472part
813)
Halogen-free to VDE 0482 part 267/ DIN
EN 50267-2-1/ IEC 60754-1 (conforms to
DIN VDE 0472 part 815)
Smoke density to VDE 0482 part 268-1
u. 2,test methodC, IEC
61034-1/61034-2, HD 606and BS 7622 part
1 and 2 (conforms toDIN VDE 0472part
816)
No toxic gases (EN 50305)
Oil- and gasoline resistant
to EN 50305
Ozon resistant to EN 50305
Low fire load (DIN 51900)
No fluor (EN 60684-2)
High voltage resistance and mechanical
influences in rough environmental
conditions
Resistant to mechanical influences in rough
environmental conditions
Good chemical durability with simultaneous
high fire safety
Reduction of toxic combustion gases and
the spread of the fire source in case of fire
increases protection against personal injury
and property damage
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Application
For fixed installation inside and outside of unprotected rail cars and buses. For connecting fixed and moving parts.
Suitable for wiring of switchboards, distribution boards, power converters, electrical panels and blocks, resistor and brake blocks.



Part no.
59262
59263
59264
59265
59266
59267
59268
59269

No.cores x
cross-sec.
mm
1x1,5
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35

Outer
approx. mm
3,6
4,0
4,9
5,5
6,5
8,7
10,2
11,5

Cop.
weight
kg/km
14,4
24,0
38,4
57,6
96,0
153,6
240,0
336,0

Weight
approx.
kg/km
24,0
34,0
53,0
74,0
118,0
182,0
274,0
379,0

AWG-No.


Part no.

59312
59313
59314
59315
59316
59317
59318

No.cores x
cross-sec.
mm
1x50
1x70
1x95
1x120
1x150
1x185
1x240

Outer
approx. mm
13,6
16,0
17,5
20,0
22,0
24,1
26,8

Cop.
weight
kg/km
480,0
672,0
912,0
1152,0
1440,0
1776,0
2304,0

Weight
approx.
kg/km
536,0
729,0
960,0
1203,0
1464,0
1802,0
2348,0

AWG-No.
-

Dimensions and specifications may be changed without prior notice. (RK01)

K 40
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Vehicle Cable FLY one colour / two colour (old type FLK),
according to DIN ISO 6722


Technical data

Cable structure

Properties

Special PVC core insulation


Temperature stability
(3000 h) -25 C to +90 C
Nominal voltage up to 24 V
Test voltage 1 kV (effective value)
Breakdown voltage
5 kV (effective value)
Specific volume resistance
min. 109 Ohm x mm

Bare copper conductor, soft annealed


electrolytic copper E-Cu58F21 according
to DIN40500 part4 (the mechanical
requirements valid for unprocessing single
wires)
Copper conductor fine wire stranded as
per DINISO6722 part3
PVC core insulation
For three-colour combinations we produce
only on request

Oil and fuel resistant as per DINISO6722


part2


Note

Minimum quantities
Per cross-section and colour combination:
2-colour
0,5 to 2,5 mm = 3 km
4,0 to 25 mm = 1 km
3-colour
0,5 to 2,5 mm = 5 km
4,0 to 25 mm = 3 km
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
PVC insulated single core cables are used for vehicle constructions.


one colour
Crosssection
mm
Part no.
0,5
Part no.
0,75
Part no.
1
Part no.
1,5
Part no.
2,5
Part no.
4
Part no.
6
Part no.
10
Part no.
16
Part no.
25
Part no.
35
Part no.
50
Part no.
70

Outer
min. - max.

Cop.
weight
kg/km

Weight
approx.
kg/km

2,0 - 2,3

4,8

9,0

2,2 - 2,5

7,2

12,0

2,4 - 2,7

9,6

15,0

2,7 - 3,0

14,4

20,0

3,3 - 3,6

24,0

32,0

4,0 - 4,4

38,4

48,0

4,6 - 5,0

57,6

68,0

6,0 - 6,5

96,0

117,0

7,0 - 8,3

154,0

189,0

9,4 - 10,4

240,0

288,0

10,8 - 11,6

336,0

382,0

12,5 - 13,5

480,0

540,0

14,5 - 15,5

672,0

744,0

black

white

blue

og

brown

green

vio

red

pink

ye

grey

29800
29801
29802
29803
29804
29805
29806
29807
29808
29809
29810
29811
29812
-

40204
40205
40206
40207
40208
40209
40210
40211
40212
40213
40214
40215
40216
-

40217
40218
40219
40220
40221
40222
40223
40224
40225
40226
40227
40228
40229
-

40230
40231
40232
40233
40234
40235
40236
40237
40238
40239
40240
40241
40242
-

40243
40244
40245
40246
40247
40248
40249
40250
40251
40252
40253
40254
40255
-

40256
40257
40258
40259
40260
40261
40262
40263
40264
40265
40266
40267
40268
-

40269
40270
40271
40272
40273
40274
40275
40276
40277
40278
40279
40280
40281
-

40282
40283
40284
40285
40286
40287
40288
40289
40290
40291
40292
40293
40294
-

40295
40296
40297
40298
40299
40300
40301
40302
40303
40304
40305
40306
40307
-

40308
40309
40310
40311
40312
40313
40314
40315
40316
40317
40318
40319
40320
-

40321
40322
40323
40324
40325
40326
40327
40328
40329
40330
40331
40332
40333
-

Dimensions and specifications may be changed without prior notice. (RK01)

K 41
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Vehicle Cable FLY one colour / two colour (old type FLK),
according to DIN ISO 6722


two colour
Crosssection
mm
Part no.
0,5
Part no.
0,75
Part no.
1
Part no.
1,5
Part no.
2,5
Part no.
4
Part no.
6
Part no.
10
Part no.
16
Part no.
25
Part no.
35
Part no.
50
Part no.
70

Outer
min. - max.

Cop.
weight
kg/km

Weight
approx.
kg/km

2,0 - 2,3

4,8

9,0

2,2 - 2,5

7,2

12,0

2,4 - 2,7

9,6

15,0

2,7 - 3,0

14,4

20,0

3,3 - 3,6

24,0

32,0

4,0 - 4,4

38,4

48,0

4,6 - 5,0

57,6

68,0

6,0 - 6,5

96,0

117,0

7,0 - 8,3

154,0

189,0

9,4 - 10,4

240,0

288,0

10,8 - 11,6

336,0

382,0

12,5 - 13,5

480,0

540,0

14,5 - 15,5

672,0

744,0

wh/gy

wh/rd

wh/bn

wh/bu

wh/bk

ye/gy

ye/rd

ye/bn

ye/bu

yellow/back

40334
40335
40336
40337
40338
40339
40340
40341
40342
40343
40344
40345
40346
-

40347
40348
40349
40350
40351
40352
40353
40354
40355
40356
40357
40358
40359
-

40360
40361
40362
40363
40364
40365
40366
40367
40368
40369
40370
40371
40372
-

40373
40374
40375
40376
40377
40378
40379
40380
40381
40382
40383
40384
40385
-

40386
40387
40388
40389
40390
40391
40392
40393
40394
40395
40396
40397
40398
-

40399
40400
40401
40402
40403
40404
40405
40406
40407
40408
40409
40410
40411
-

40412
40413
40414
40415
40416
40417
40418
40419
40420
40421
40422
40423
40424
-

40425
40426
40427
40428
40429
40430
40431
40432
40433
40434
40435
40436
40437
-

40438
40439
40440
40441
40442
40443
40444
40445
40446
40447
40448
40449
40450
-

40451
40452
40453
40454
40455
40456
40457
40458
40459
40460
40461
40462
40463
-

two colour
Crosssection
mm
Part no.
0,5
Part no.
0,75
Part no.
1
Part no.
1,5
Part no.
2,5
Part no.
4
Part no.
6
Part no.
10
Part no.
16
Part no.
25
Part no.
35
Part no.
50
Part no.
70

Outer
min. - max.

Cop.
weight
kg/km

Weight
gy/gn
approx. kg/km

gy/rd

gy/bn

gy/bk

gn/wh

gn/gy

gn/bn

gn/bu

green/black

40464
40465
40466
40467
40468
40469
40470
40471
40472
40473
40474
40475
40476
-

40477
40478
40479
40480
40481
40482
40483
40484
40485
40486
40487
40488
40489
-

40490
40491
40492
40493
40494
40495
40496
40497
40498
40499
40500
40501
40502
-

40802
40803
40804
40805
40806
40807
40808
40809
40810
40811
40812
40813
40814
-

40503
40504
40505
40506
40507
40508
40509
40510
40511
40512
40513
40514
40515
-

40516
40517
40518
40519
40520
40521
40522
40523
40524
40525
40526
40527
40528
-

40529
40530
40531
40532
40533
40534
40535
40536
40537
40538
40539
40540
40541
-

40542
40543
40544
40545
40546
40547
40548
40549
40550
40551
40552
40553
40554
-

40555
40556
40557
40558
40559
40560
40561
40562
40563
40564
40565
40566
40567
-

2,0 - 2,3

4,8

9,0

2,2 - 2,5

7,2

12,0

2,4 - 2,7

9,6

15,0

2,7 - 3,0

14,4

20,0

3,3 - 3,6

24,0

32,0

4,0 - 4,4

38,4

48,0

4,6 - 5,0

57,6

68,0

6,0 - 6,5

96,0

117,0

7,0 - 8,3

154,0

189,0

9,4 - 10,4

240,0

288,0

10,8 - 11,6

336,0

382,0

12,5 - 13,5

480,0

540,0

14,5 - 15,5

672,0

744,0

Dimensions and specifications may be changed without prior notice.

K 42
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Vehicle Cable FLY one colour / two colour (old type FLK),
according to DIN ISO 6722


two colour
Crosssection
mm
Part no.
0,5
Part no.
0,75
Part no.
1
Part no.
1,5
Part no.
2,5
Part no.
4
Part no.
6
Part no.
10
Part no.
16
Part no.
25
Part no.
35
Part no.
50
Part no.
70

Outer
min. - max.

Cop.
weight
kg/km

Weight
approx.
kg/km

2,0 - 2,3

4,8

9,0

2,2 - 2,5

7,2

12,0

2,4 - 2,7

9,6

15,0

2,7 - 3,0

14,4

20,0

3,3 - 3,6

24,0

32,0

4,0 - 4,4

38,4

48,0

4,6 - 5,0

57,6

68,0

6,0 - 6,5

96,0

117,0

7,0 - 8,3

154,0

189,0

9,4 - 10,4

240,0

288,0

10,8 - 11,6

336,0

382,0

12,5 - 13,5

480,0

540,0

14,5 - 15,5

672,0

744,0

rd/wh

rd/ye

rd/gy

rd/gn

rd/bu

rd/bk

bn/wh

bn/ye

bn/gn

bn/bk

40568
40569
40570
40571
40572
40573
40574
40575
40576
40577
40578
40579
40580
-

40581
40582
40583
40584
40585
40586
40587
40588
40589
40590
40591
40592
40593
-

40594
40595
40596
40597
40598
40599
40600
40601
40602
40603
40604
40605
40606
-

40607
40608
40609
40610
40611
40612
40613
40614
40615
40616
40617
40618
40619
-

40620
40621
40622
40623
40624
40625
40626
40627
40628
40629
40630
40631
40632
-

40633
40634
40635
40636
40637
40638
40639
40640
40641
40642
40643
40644
40645
-

40646
40647
40648
40649
40650
40651
40652
40653
40654
40655
40656
40657
40658
-

40659
40660
40661
40662
40663
40664
40665
40666
40667
40668
40669
40670
40671
-

40672
40673
40674
40675
40676
40677
40678
40679
40680
40681
40682
40683
40684
-

40685
40686
40687
40688
40689
40690
40691
40692
40693
40694
40695
40696
40697
-

two colour
Crosssection
mm
Part no.
0,5
Part no.
0,75
Part no.
1
Part no.
1,5
Part no.
2,5
Part no.
4
Part no.
6
Part no.
10
Part no.
16
Part no.
25
Part no.
35
Part no.
50
Part no.
70

Outer
min. - max.

Cop.
weight
kg/km

Weight
bu/wh
approx. kg/km

bu/ye

bu/gn

bu/rd

bk/wh

bk/ye

bk/gn

bk/rd

40698
40699
40700
40701
40702
40703
40704
40705
40706
40707
40708
40709
40710
-

40711
40712
40713
40714
40715
40716
40717
40718
40719
40720
40721
40722
40723
-

40724
40725
40726
40727
40728
40729
40730
40731
40732
40733
40734
40735
40736
-

40737
40738
40739
40740
40741
40742
40743
40744
40745
40746
40747
40748
40749
-

40750
40751
40752
40753
40754
40755
40756
40757
40758
40759
40760
40761
40762
-

40763
40764
40765
40766
40767
40768
40769
40770
40771
40772
40773
40774
40775
-

40776
40777
40778
40779
40780
40781
40782
40783
40784
40785
40786
40787
40788
-

40789
40790
40791
40792
40793
40794
40795
40796
40797
40798
40799
40800
40801
-

2,0 - 2,3

4,8

9,0

2,2 - 2,5

7,2

12,0

2,4 - 2,7

9,6

15,0

2,7 - 3,0

14,4

20,0

3,3 - 3,6

24,0

32,0

4,0 - 4,4

38,4

48,0

4,6 - 5,0

57,6

68,0

6,0 - 6,5

96,0

117,0

7,0 - 8,3

154,0

189,0

9,4 - 10,4

240,0

288,0

10,8 - 11,6

336,0

382,0

12,5 - 13,5

480,0

540,0

14,5 - 15,5

672,0

744,0

Dimensions and specifications may be changed without prior notice.

K 43
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Vehicle Cable FLRY FLRY-Type A (FLK-R) / -Type B (FLK-D)




Technical data

Cable structure

Properties

Special PVC core insulation


Temperature stability
(3000 h) -40C to +105C
Nominal voltage up to 24 V
Test voltage
1 kV (effective value)
Breakdown voltage
5 kV (effective value)
Specific volume resistance
min. 109 Ohm x mm
Type A = Conductor make-up symmetrical
(1+6+12), number of single wires are odd
number; a single wire laying at the centre
of the cross-section.

Bare copper conductor, soft annealed


electrolytic copper E-Cu58F21 according
to DIN40500 part4 (the mechanical
requirements valid for unprocessing single
wires)
Stranded copper conductor bare,
conductor make-up as per DIN72551
Type A: Conductor make-up symmetrical
Type B: Conductor make-up
unsymmetrical
Special PVC core insulation


Oil and fuel resistant as per DINISO6722


part2
Special characteristics
Place and weight saving by using the
reduced insulation wall thickness.
Requirements and tests
As per DIN 72551 part 5


Note

Indication for order


Please mention the core colour and colour
combination clearly to your order,
because a re-acceptance of false ordered
articles is impossible.
Minimum quantities
Per cross-section and colour combination:
2-colour
0,5 to 2,5 mm = 3 km
4,0 to 25 mm = 1 km
3-colour
0,5 to 2,5 mm = 5 km
4,0 to 25 mm = 3 km
For three-colour combinations we produce
only on request.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
PVC insulated single core cables are used for vehicle constructions.


FLRY - Type A (FLK-R)


Crosssection
mm
Part no.
0,35
Part no.
0,5

Outer
min. - max.

Cop.
weight
kg/km

Weight
approx.
kg/km

1,2 - 1,3

3,4

4,5

1,4 - 1,6

4,8

6,6

AWG-No. AWG-No. AWG-No. AWG-No. AWG-No. AWG-No. AWG-No. AWG-No. AWG-No. AWG-No. AWG-No.
black
white
blue
og
brown
green
vio
red
pink
ye
grey
28484
28495
-

28485
28496
-

28486
28497
-

28487
28498
-

28488
28499
-

28489
28500
-

28490
28501
-

28491
28502
-

28492
28503
-

28493
28504
-

28494
28505
-

FLRY - Type B (FLK-D)


Crosssection
mm
Part no.
0,75
Part no.
1
Part no.
1,5
Part no.
2,5
Part no.
4
Part no.
6

Outer
min. - max.
1,7 - 1,9

Cop.
weight
kg/km

Weight
approx.
kg/km

7,2

9,0

1,9 - 2,1

9,6

11,0

2,2 - 2,4

14,4

16,0

2,7 - 3,0

24,0

26,0

3,4 - 3,7

38,0

42,0

4,0 - 4,3

58,0

61,0

AWG-No. AWG-No. AWG-No. AWG-No. AWG-No. AWG-No. AWG-No. AWG-No. AWG-No. AWG-No. AWG-No.
black
white
blue
og
brown
green
vio
red
pink
ye
grey
28506
28517
28528
28539
28550
28561
-

28507
28518
28529
28540
28551
28562
-

28508
28519
28530
28541
28552
28563
-

28509
28520
28531
28542
28553
28564
-

28510
28521
28532
28543
28554
28565
-

28511
28522
28533
28544
28555
28566
-

28512
28523
28534
28545
28556
28567
-

28513
28524
28535
28546
28557
28568
5/0

28514
28525
28536
28547
28558
28569
-

28515
28526
28537
28548
28559
28570
-

28516
28527
28538
28549
28560
28571
-

Dimensions and specifications may be changed without prior notice. (RK01)

K 44
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Compensating Cables

L1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Compensating Cables

Technical data

Cable structure

Application

Special insulation as per requirement of


PVC, Silicone, Fluorinated polymeric or
Glasslament
Coductor resistance
according DIN 43713
Fe:
0,080 Ohm/m
CuNi: 0,327 Ohm/m
NiCr: 0,07 Ohm/m
Ni:
0,3 Ohm/m
PtRh: 0,023 Ohm/m
Pt:
0,041 Ohm/m
Test voltage
for PVC-, Fluorinated polymeric- and
Silicone cables
core/core
500 V
core/screen
500 V
screen/screen 500 V
Test voltage
Cables with Glasslament
core/core
500 V
Insulation resistance
for PVC, Silicone and Fluorinated
polymeric
min. 10 MOhmx km
Capacitance
(approx. value) nF/km
Stranded Solid
Stranded
wire
wire
wire
1,5 mm2 1,5 mm2 0,22mm2
PVC
core
135
138
115
pair
screened 240
245
180
FEP
core
60
60
45
pair
screened 120
120
70
Silicone
core
80
70
45

Conductors of stranded wires or solid,


insulated with special material
Conductors: Fe/CuNi, Ni/Cr Ni or Pt Rh/Pt
Insulations: PVC, Silicone, Fluorinated
polymeric or Glasslament
Core identication:
colour coded, single colour (see also
colour-identication table)
Colour code for pairs
from 2 pairs and above the individual
pairs number coded
Jacketing materials are of PVC, Silicone,
Fluorinated polymeric or Glasslamentbraiding
Screened braiding of galvanized steel
wire (type SY) or galvanized copper wire
braided screen.

Compensating cables are an essential


part of exact and precise measuring
capabilities. They are used as extension
leads from the thermocoupling elements
to the measure gauge.
Compensating cables are made up of a
positive and a negative core which, at a
thermocoupler temperature of up to
+200C, retain the same properties as a
Thermopair according to DIN 43710.

Induction (guiding value)


for PVC, Fluorinated polymeric and
Silicon cables < 1 mH/km
Corrosiveness of combustion gases
(free from halogen)
Silicone + Glasslament
Test method to VDE 0472 part 813 and
IEC 60754-1
no evolution of corrosive gases
Behaviour in re
PVC sheath self-extinguishing and ame
retardant acc. to VDE 0482-322-1-2, DIN
EN 60332-1-2/IEC 60332-1 (equals to DIN
VDE 0472 part 804 test method B)

Measuring
For temperature measuring the temperature dependent upon the characteristics
of materials are taken into consideration,
for example the expansion thermometer
of the thermocouples etc.
Temperature measuring appliances with a
thermocouple as transmitter of the
measured value consists generally of the
thermocouple, the connection between
the junction and a reference part, a
comparative part where the temperature is
known under a voltage measuring device.
The tted connection line between the
thermocouple and the comparative part
must have the same thermoelectrical
characteristics as the thermocouple.
The difference of temperature is
measured between the measuring point
and the comparative part of the cable.
Tolerance of the meter resistance 10%.
For hazardous areas
The compensating cables for thermoelements with plastic insulation are
permitted to imprint colour longitudinal
stripe of the same belonging thermoelement types, and as:
Cu/Cu-Ni = brown, Fe/Cu-Ni = dark blue,
NiCr/Ni = green, Pt-Rh/Pt = white
The compensating cables for thermoelements with mineral insulation or with
metal braiding must be identied with a
light blue coloured tape of sufcient
width for intrinsic safe, which can be
webed in the braiding.

Materials
(Compensating wires and strands)
We distinguish between original raw
materials and substitutes.
Compensating wires and strands of original raw materials are made of the
same material as the corresponding
thermocouple and they are called
Thermocable or Thermocouplecable.
Compensating wires and strands of
substitude materials, which consist of
alloys and which are not identical with
the corresponding thermocouple are
called Compensating Cable.
Substitute materials are used for
the thermopairs Type K and Type N.
Precious metal thermopairs
Type R, Type S, Type B consist of thermomaterials.
Thermocouple cables
Thermocouple cables consist of the same
element material as the thermocouple
and are tested to the same temperatures. These cables are manufactured to
customers request.
Note
Thermomaterials consist of very expensive materials while the substitutes are
much cheaper.

Flame test to DIN VDE 0482 part 266-2/


HD 405.3, BS 4066 part 3/EN 50266-2/
IEC 60332-3 (equivalent DIN VDE 0472
part 804 test method C)

L2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Colour identication and temperature ranges


Identication
letter of
Thermopairs

Material
combination

NF C 42-324

+
(plus)

(minus)

THL

Cu

Cu Ni

TX

TC

TX

25C to +100C

25C to +100C

0C to +100C

JX

JC

JX

25C to +200C

25C to +250C

0C to +200C

EX

EC

EX

25C to +200C

25C to +250C

0C to +200C

KX

KC

KX

25C to +200C

25C to +200C

0C to +200C

Cu

Cu Ni

Fe

Cu Ni

Fe

Cu Ni

Ni Cr

Cu Ni

Ni Cr

BS 4937

Ni Cr

Ni

Identication

Ni

Identication
AGL

THL

AGL

WC
0C to +150C

Ni Cr

Ni

VC

VX

0C to +100C -

0C to +100C

Ni Cr Si

Ni Si

R
S

PtRh 13
PtRh 10

Pt
Pt

SC

SX

0C to +200C

0C to +200C

PtRh 30

PtRh 6

BC
0C to +100C

The highest application temperature of the insulating materials


or the application temperature range of the conductor material
is limited for the application temperature range of the cable.
Valid with the corresponding lower value.

For intrinsically safe installation generally provides


with a blue coloured jacket and an element with the
associated identication stripe.

L3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

for Thermo- and Compensating Cables

ANSI MC 96.1

DIN IEC 584

Identication

DIN 43710*

Identication

THL

AGL

THL

TX

TX

0C to +100C

25C to +100C

Identication
AGL

THL

AGL

UX
0C to +200C

JX

JX

0C to +200C

25C to +200C

LX
0C to +200C

EX

EX

0C to +200C

25C to +200C

KX

KX

0C to +200C

25C to +200C

KCA
0C to +150C

KCB
0C to +100C

NX
25C to +200C

NC

0C to +150C

RCA/SCA
SX

0C to +100C

0C to +200C

RCB/SCB
0C to +200C

BX
0C to +100C

Other Colour code


on request.
THL = Thermocouple wire
AGL = Compensating cable

BC

(adapted to
DIN 43710/85)

0C to +100C

Examples: KX

Thermocouple wire KX (plus)


KX (minus)
KCA Compensating cable KCA (plus)
KCA (minus)

 positive core
 negative core
 positive core
 negative core

for THL KX
for THL KX
for AGL KC
for AGL KC

L4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Compensating Cables
Materials for compensating cables
Standards

DIN 43710

DIN IEC 584

NF

ANSI

Art of thermocouple elements

Materials of compensating cables

Type

Plus-Pol
(+)

Minus-Pol
()

Code

Plus-Pol
(+)

Minus-Pol
()

Cu

CuNi

UX

Cu

CuNi

Fe

CuNi

LX

Fe

CuNi

Cu

CuNi

TX

Cu

CuNi

NiCr

CuNi

EX

NiCr

CuNi

Fe

CuNi

JX

Fe

CuNi

NiCr

Ni

KX

NiCr

Ni

NiCr

Ni

KC 1

Fe

CuNi

NiCr

Ni

KC 2

Cu

CuNi

R/S

Pt 13/10 Rh

Pt

RC A/SC A

Cu

CuNi

R/S

Pt 13/10 Rh

Pt

RC B/SC B

Cu

CuNi

Cu

CuNi

TX

Cu

CuNi

NiCr

CuNi

EX

NiCr

CuNi

Fe

CuNi

JX

Fe

CuNi

NiCr

Ni

KX

NiCr

Ni

NiCr

Ni

VC

Cu

CuNi

NiCr

Ni

WC

Fe

CuNi

R/S

Pt 13/10 Rh

Pt

RC/SC

Cu

CuNi

Pt 30 Rh

Pt 6 Rh

BC

Cu-Leg.

Cu

Cu

CuNi

TX

Cu

CuNi

NiCr

CuNi

EX

NiCr

CuNi

Fe

CuNi

JX

Fe

CuNi

NiCr

Ni

KX

NiCr

Ni

R/S

Pt 13/10 Rh

Pt

RX/SX

Cu

CuNi

Pt 30 Rh

Pt 6 Rh

BX

Cu

Cu

Characteristics of the conductors for thermo-pairs and compensating cables


Materials

Main components
approx. %

Cu

Ni

Mn

Others

g
cm3

Ohm cm

Resistance value
(nominal value)
Ohm/m
mm
mm
0,20
1,38

CuNi

55

44

8,85

49

15,60

0,328

SoNi

51

45

Fe2

8,85

51

16,26

0,341

NiCr

Rest

Cr 10

8,7

72

22,90

0,481

Ni

95

MnAISi

8,55

27

8,59

0,180

SoPt

95

8,9

12

3,82

0,0802

0,54

0,011

ECu

Density
at 20C

according to DIN 46 431

8,9

Specic
resistance
at 20C

1,7

Fe

7,85

12

3,82

0,08

BPX

97

8,9

12,5

3,98

0,084

L5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Compensating Cables
ThermoType
Core
Jacket/
Outer
Form TempeTempepair
insulation Armouring/

rature
rature
materials
Jacket
ca. mm
range of
range at
to
insulation
installation
DIN 43713
C
C
Single pair: 2 x 1,5 mm2 (L = stranded wires, conductor make-up 48 x 0,20 mm; M = solid conductor, diameter 1,38 mm)
48001 FE-CuNi (Ko)
L
AE 1 L stranded
PVC

5,4
round
stationary:
48002 SoNiCr-SoNi
K
AN 1 L stranded
PVC

5,4
round
10C
25C to +70C
48003 SoPtRh-SoPt
S
AP 1 L stranded
PVC

5,4
round to
flexing:
48230 Cu-CuNi (Ko)
U
AC 1 L stranded
PVC

5,4
round +80C
5C to +70C
48478 Fe-CuNi
J
AF 1 L stranded
PVC

5,4
round

Min.
bending
radius
..x
cable

48004
48005
48006
48231

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 1 M stranded
AN 1 M stranded
AP 1 M stranded
AC 1 M stranded

PVC
PVC
PVC
PVC

5,4
5,4
5,4
5,4

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

10
10
10
10

48007
48008
48009
48232

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 1 L-SIL stranded
AN 1 L-SIL stranded
AP 1 L-SIL stranded
AC 1 L-SIL stranded

Silicone
Silicone
Silicone
Silicone

5,4
5,4
5,4
5,4

round
round
round
round

60C
to
+180C

stationary:
25C to +180C
flexing:
25C to +180C
(short time +200C)

48233
48234
48235
48236

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 2 M-SIL stranded
AN 2 M-SIL stranded
AP 2 M-SIL stranded
AC 2 M-SIL stranded

Silicone
Silicone
Silicone
Silicone

textile tape/
lead sheath/
tin. steel wire
braiding

7,8
7,8
7,8
7,8

round
round
round
round

60C
to
+180C

stationary:
25C to +180C
flexing:
25C to +180C
(short time +200C)

48010
48011
48012
48237

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 3 L parallel
AN 3 L parallel
AP 3 L parallel
AC 3 L parallel

glass filam.
glass filam.
glass filam.
glass filam.

glass filam. braid.


glass filam. braid.
glass filam. braid.
glass filam. braid.

5,0x7,2
5,0x7,2
5,0x7,2
5,0x7,2

oval
oval
oval
oval

60C
to
+200C

stationary:
25C to +200C
flexing:
25C to +200C

7,5
7,5
7,5
7,5

64
64
64
64

48238
48239
48240
48241

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 3 Ln-SIL parallel
AN 3 Ln-SIL parallel
AP 3 Ln-SIL parallel
AC 3 Ln-SIL parallel

Silicone
Silicone
Silicone
Silicone

Silicone
Silicone
Silicone
Silicone

5,2x7,4
5,2x7,4
5,2x7,4
5,2x7,4

oval
oval
oval
oval

60C
to
+180C

stationary:
25C to +180C
flexing:
25C to +180C
(short time +200C)

7,5
7,5
7,5
7,5

62
62
62
62

48013
48014
48015
48242

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 4 L parallel
AN 4 L parallel
AP 4 L parallel
AC 4 L parallel

glass filam.
glass. filam. braid./
glass filam.
galv. steel wireglass filam. braiding
glass filam.

5,8x8,0
5,8x8,0
5,8x8,0
5,8x8,0

oval
oval
oval
oval

60C
to
+200C

stationary:
25C to +200C
flexing:
25C to +200C

7,5
7,5
7,5
7,5

87
87
87
87

48016
48017
48018
48243

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 4 Ln-SIL
AN 4 Ln-SIL
AP 4 Ln-SIL
AC 4 Ln-SIL

Silicone
Silicone
Silicone
Silicone

Silicone/
galv. steel wirebraiding

6,0x8,2
6,0x8,2
6,0x8,2
6,0x8,2

oval
oval
oval
oval

60C
to
+180C

stationary:
25C to +180C
flexing:
25C to +180C
(short time +200C)

7,5
7,5
7,5
7,5

85
85
85
85

48244
48245
48246
48247

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 5 L
AN 5 L
AP 5 L
AC 5 L

PVC
PVC
PVC
PVC

PETP-tape/
Cu-solid wire
braiding/
tinned/PVC-jacket

8,1
8,1
8,1
8,1

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

93
93
93
93

48248
48249
48250
48251

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 6 L-SIL
AN 6 L-SIL
AP 6 L-SIL
AC 6 L-SIL

Silicone
Silicone
Silicone
Silicone

PETP-tape/
Cu-ground wire
0,5 mm /
Alu-tape/Silicone

8,0
8,0
8,0
8,0

round
round
round
round

60C
to
+180C

stationary:
25C to +180C
flexing:
25C to +180C
(short time +200C)

7,5
7,5
7,5
7,5

94
94
94
94

48252
48253
48254
48255

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 6 M-SIL
AN 6 M-SIL
AP 6 M-SIL
AC 6 M-SIL

Silicone
Silicone
Silicone
Silicone

PETP-tape/
Cu-ground wire
0,5 mm /
Alu-tape/Silicone

7,8
7,8
7,8
7,8

round
round
round
round

60C
to
+180C

stationary:
25C to +180C
flexing:
25C to +180C
(short time +200C)

48019
48020
48021
48256

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 7 L parallel
AN 7 L parallel
AP 7 L parallel
AC 7 L parallel

PVC
PVC
PVC
PVC

glass filament
glass filament
glass filament
glass filament

5,5x8,2
5,5x8,2
5,5x8,2
5,5x8,2

oval
oval
oval
oval

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

60
60
60
60

48022
48023
48024
48257

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 8 L
AN 8 L
AP 8 L
AC 8 L

PVC
PVC
PVC
PVC

glass filament/
galv. steel wire
braiding

6,3x9,0
6,3x9,0
6,3x9,0
6,3x9,0

oval
oval
oval
oval

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

82
82
82
82

48025
48026
48027
48258
48479

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)
Fe-CuNi

L
K
S
U
J

AE 9 L
AN 9 L
AP 9 L
AC 9 L
AF 9 L

PVC
PVC
PVC
PVC
PVC

PVC
PVC
PVC
PVC
PVC

7,0
7,0
7,0
7,0
7,0

round
round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5
7,5

79
79
79
79
79

48028
48029
48030
48259
48480

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)
Fe-CuNi

L
K
S
U
J

AE 9-2 LS
AN 9-2 LS
AP 9-2 LS
AC 9-2 LS
AF 9-2 LS

PVC
PVC
PVC
PVC
PVC

PVC/galv.
steel wire
braiding

7,8
7,8
7,8
7,8
7,8

round
round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5
7,5

108
108
108
108
108

48031
48032
48069
48260

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-2 LSY
AN 9-2 LSY
AP 9-2 LSY
AC 9-2 LSY

PVC
PVC
PVC
PVC

PVC/galv.
steel wire
braiding/
PVC

9,8
9,8
9,8
9,8

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

147
147
147
147

L = conductor of stranded wires


M = solid conductor
tin. = tinned
galv. = galvanized

7,5
7,5
7,5
7,5
7,5

7,5
7,5
7,5
7,5
15
15
15
15

12
12
12
12

Weight
ca.
kg/km

40
40
40
40
40
40
40
40
40
40
40
40
40
248
248
248
248

92
92
92
92

Continuation

Thermopair Type

Part
No.

L6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Compensating Cables
Type

Core
Jacket/
insulation Armouring/
Jacket

Outer
Form

ca. mm

Temperature
range of
insulation
C

Temperature
range at
installation
C

Min.
bending
radius
..x
cable

Weight
ca.
kg/km

Single pair: 2 x 1,5 mm2 (L = stranded wires, conductor make-up 48 x 0,20 mm; M = solid conductor, diameter 1,38 mm)
48033 FE-CuNi (Ko)
L
AE 9 M
PVC
PVC
7,0
round
stationary:
48034 SoNiCr-SoNi
K
AN 9 M
PVC
PVC
7,0
round 10C
25C to +70C
to
flexing:
48035 SoPtRh-SoPt
S
AP 9 M
PVC
PVC
7,0
round
+80C
-5C to +70C
48261 Cu-CuNi (Ko)
U
AC 9 M
PVC
PVC
7,0
round

12
12
12
12

79
79
79
79

48262
48263
48264
48265

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-2 MSY
AN 9-2 MSY
AP 9-2 MSY
AC 9-2 MSY

PVC
PVC
PVC
PVC

PVC/galv.
steel wire braiding/
PVC

9,6
9,6
9,6
9,6

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
-5C to +70C

12
12
12
12

144
144
144
144

48036
48037
48038
48266

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 10 L-SIL parallel
AN 10 L-SIL parallel
AP 10 L-SIL parallel
AC 10 L-SIL parallel

Silicone
Silicone
Silicone
Silicone

glass filament
glass filament
glass filament
glass filament

5,5x8,2
5,5x8,2
5,5x8,2
5,5x8,2

oval
oval
oval
oval

60C
to
+180C

stationary:
25C to +180C
flexing:
25C to +180C
(short time +200C)

7,5
7,5
7,5
7,5

59
59
59
59

48039
48040
48041
48267

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 11 L
AN 11 L
AP 11 L
AC 11 L

Silicone
Silicone
Silicone
Silicone

glass filament/
galv. steel wire
braiding

6,3x9,0
6,3x9,0
6,3x9,0
6,3x9,0

oval
oval
oval
oval

60C
to
+180C

stationary:
25C to +180C
flexing:
25C to +180C
(short time +200C)

7,5
7,5
7,5
7,5

82
82
82
82

48042
48043
48044
48268

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 11 Lr
AN 11 Lr
AP 11 Lr
AC 11 Lr

Silicone
Silicone
Silicone
Silicone

glass filament/
galv. steel wire
braiding

6,7
6,7
6,7
6,7

round
round
round
round

60C
to
+180C

stationary:
25C to +180C
flexing:
25C to +180C
(short time +200C)

7,5
7,5
7,5
7,5

83
83
83
83

48045
48046
48047
48269

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 11 Mr
AN 11 Mr
AP 11 Mr
AC 11 Mr

Silicone
Silicone
Silicone
Silicone

glass filament/
galv. steel wire
braiding

6,5
6,5
6,5
6,5

round
round
round
round

60C
to
+180C

stationary:
25C to +180C
flexing:
25C to +180C
(short time +200C)

48048
48049
48050
48270
48481

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)
Fe-CuNi

L
K
S
U
J

AE 12 L parallel
AN 12 L parallel
AP 12 L parallel
AC 12 L parallel
AF 12 L parallel

PVC
PVC
PVC
PVC
PVC

PVC
PVC
PVC
PVC
PVC

4,3x7,0
4,3x7,0
4,3x7,0
4,3x7,0
4,3x7,0

oval
oval
oval
oval
oval

10C
to
+80C

stationary:
25C to +70C
flexing:
-5C to +70C

48051
48052
48053
48271

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 12 M parallel
AN 12 M parallel
AP 12 M parallel
AC 12 M parallel

PVC
PVC
PVC
PVC

PVC
PVC
PVC
PVC

4,2x6,8
4,2x6,8
4,2x6,8
4,2x6,8

oval
oval
oval
oval

10C
to
+80C

stationary:
25C to +70C
flexing:
-5C to +70C

48054
48055
48056
48272

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 13 L parallel
AN 13 L parallel
AP 13 L parallel
AC 13 L parallel

Silicone
Silicone
Silicone
Silicone

glass filament
glass filament
glass filament
glass filament

3,2x5,9
3,2x5,9
3,2x5,9
3,2x5,9

oval
oval
oval
oval

60C
to
+180C

stationary:
25C to +180C
flexing:
25C to +180C
(short time +200C)

48057
48058
48059
48273

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 13 M
AN 13 M
AP 13 M
AC 13 M

Silicone
Silicone
Silicone
Silicone

glass filament
glass filament
glass filament
glass filament

3,5x6,0
3,5x6,0
3,5x6,0
3,5x6,0

oval
oval
oval
oval

60C
to
+180C

stationary:
25C to +180C
flexing:
25C to +180C
(short time +200C)

48060
48061
48062
48274

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 14 L
AN 14 L
AP 14 L
AC 14 L

Silicone
Silicone
Silicone
Silicone

11,7
special Silicone com11,7
pound, foamed/
11,7
galv. steel tubing
11,7

round
round
round
round

60C
to
+180C

stationary:
25C to +180C
flexing:
25C to +180C
(short time +200C)

7,5
7,5
7,5
7,5

196
196
196
196

48063
48064
48065
48275
48482

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)
Fe-CuNi

L
K
S
U
J

AE 15 L
AN 15 L
AP 15 L
AC 15 L
AF 15 L

Silicone
Silicone
Silicone
Silicone
Silicone

Silicone
Silicone
Silicone
Silicone
Silicone

7,7
7,7
7,7
7,7
7,7

round
round
round
round
round

60C
to
+180C

stationary:
25C to +180C
flexing:
25C to +180C
(short time +200C)

7,5
7,5
7,5
7,5
7,5

76
76
76
76
76

48066
48067
48068
48276

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 15 LS
AN 15 LS
AP 15 LS
AC 15 LS

Silicone
Silicone
Silicone
Silicone

Silicone/
galv. steel wire
braiding

7,8
7,8
7,8
7,8

round
round
round
round

10C
to
+180C

stationary:
25C to +180C
flexing:
25C to +180C
(short time +200C)

7,5
7,5
7,5
7,5

105
105
105
105

48277
48278
48279
48280

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 16 L-SIL parallel
AN 16 L-SIL parallel
AP 16 L-SIL parallel
AC 16 L-SIL parallel

Silicone
Silicone
Silicone
Silicone

2,8x5,6
2,8x5,6
2,8x5,6
2,8x5,6

oval
oval
oval
oval

10C
to
+180C

stationary:
25C to +180C
flexing:
25C to +180C
(short time +200C)

7,5
7,5
7,5
7,5

38
38
38
38

48281
48282
48283
48284

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 18 L
AN 18 L
AP 18 L
AC 18 L

HELUFLON-FEP
HELUFLON-FEP
HELUFLON-FEP
HELUFLON-FEP

HELUFLON-FEP
HELUFLON-FEP
HELUFLON-FEP
HELUFLON-FEP

4,4
4,4
4,4
4,4

round
round
round
round

100C
to
+200C

stationary:
25C to +205C
flexing:
25C to +205C

7,5
7,5
7,5
7,5

37
37
37
37

48285
48286
48287
48288

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 19 L
AN 19 L
AP 19 L
AC 19 L

HELUFLON-FEP
HELUFLON-FEP
HELUFLON-FEP
HELUFLON-FEP

PETP-tape/
Cu-solid wire
braiding
HELUFLON-FEP

5,6
5,6
5,6
5,6

round
round
round
round

100C
to
+200C

stationary:
25C to +205C
flexing:
25C to +205C

7,5
7,5
7,5
7,5

60
60
60
60

12
12
12
12
7,5
7,5
7,5
7,5
7,5
12
12
12
12
7,5
7,5
7,5
7,5
12
12
12
12

83
83
83
83
69
69
69
69
69
61
61
61
61
45
45
45
45
45
45
45
45

Continuation

Thermopair
materials
to
DIN 43713

Thermopair Type

Part
No.

L = conductor of stranded wires


M = solid conductor
tin. = tinned
galv. = galvanized

L7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Compensating Cables
Min.
bending
radius
..x
cable

48293 Fe-CuNi (Ko)


L
AE 20 M
PVC
8,2
round
stationary:
PETP-tape/
48294 SoNiCr-SoNi
K
AN 20 M
PVC
8,2
round 10C
25C to +70C
Cu-ground wire
to
flexing:
bare 0,5 mm /
48295 SoPtRh-SoPt
S
AP 20 M
PVC
8,2
round
+80C
5C to +70C
Alu-tape/PVC
48296 Cu-CuNi (Ko)
U
AC 20 M
PVC
8,2
round
Multi-paired: 2 pairs (4 x 1,5 mm2) (L = stranded wires, conductor make-up 48 x 0,20 mm; M = solid conductor, diameter 1,38 mm)
48100 Fe-CuNi (Ko)
L
AE 9-4 L
PVC
PVC
8,3
round
stationary:
48101 SoNiCr-SoNi
K
AN 9-4 L
PVC
PVC
8,3
round 10C
25C to +70C
48102 SoPtRh-SoPt
S
AP 9-4 L
PVC
PVC
8,3
round to
flexing:
48297 Cu-CuNi (Ko)
U
AC 9-4 L
PVC
PVC
8,3
round +80C
5C to +70C
48483 Fe-CuNi
J
AF 9-4 L
PVC
PVC
8,3
round

12
12
12
12

48298
48299
48300
48301

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-4 LS
AN 9-4 LS
AP 9-4 LS
AC 9-4 LS

PVC
PVC
PVC
PVC

PVC/galv.
steel wire
braiding

48137
48138
48139
48302

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-4 LSY
AN 9-4 LSY
AP 9-4 LSY
AC 9-4 LSY

PVC
PVC
PVC
PVC

48303
48304
48305
48306

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-4 MSY
AN 9-4 MSY
AP 9-4 MSY
AC 9-4 MSY

PVC
PVC
PVC
PVC

7,5
7,5
7,5
7,5

Weight
ca.
kg/km

75
75
75
75
82
82
82
82

7,5
7,5
7,5
7,5
7,5

125
125
125
125
125

8,9
8,9
8,9
8,9

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

155
155
155
155

PVC/galv.
steel wire braiding/
PVC

11,4
11,4
11,4
11,4

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

220
220
220
220

PVC/galv.
steel wire braiding/
PVC

11,0
11,0
11,0
11,0

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

48307 Fe-CuNi (Ko)


L
AE 20-4 M
PVC
10,8
round
stationary:
PETP-tape/
10C
48308 SoNiCr-SoNi
K
AN 20-4 M
PVC
10,8
round
25C to +70C
Cu-ground wire
to
flexing:
bare 0,5 mm /
48309 SoPtRh-SoPt
S
AP 20-4 M
PVC
10,8
round +80C
5C to +70C
Alu-tape/PVC
48310 Cu-CuNi (Ko)
U
AC 20-4 M
PVC
10,8
round
Multi-paired: 3 pairs (6 x 1,5 mm2) (L = stranded wires, conductor make-up 48 x 0,20 mm; M = solid conductor, diameter 1,38 mm)
48103 Fe-CuNi (Ko)
L
AE 9-6 L
PVC
PVC
10,3
round
stationary:
48104 SoNiCr-SoNi
K
AN 9-6 L
PVC
PVC
10,3
round 10C
25C to +70C
48105 SoPtRh-SoPt
S
AP 9-6 L
PVC
PVC
10,3
round to
flexing:
+80C
48311 Cu-CuNi (Ko)
U
AC 9-6 L
PVC
PVC
10,3
round
5C to +70C
48484 Fe-CuNi
J
AF 9-6 L
PVC
PVC
10,3
round

12
12
12
12

210
210
210
210

12
12
12
12

137
137
137
137

7,5
7,5
7,5
7,5
7,5

190
190
190
190
190

48312
48313
48314
48315

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-6 LS
AN 9-6 LS
AP 9-6 LS
AC 9-6 LS

PVC
PVC
PVC
PVC

PVC/galv.
steel wire
braiding

10,9
10,9
10,9
10,9

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

226
226
226
226

48140
48141
48142
48316

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-6 LSY
AN 9-6 LSY
AP 9-6 LSY
AC 9-6 LSY

PVC
PVC
PVC
PVC

PVC/galv.
steel wire braiding/
PVC

13,4
13,4
13,4
13,4

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

292
292
292
292

48317
48318
48319
48320

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-6 MSY
AN 9-6 MSY
AP 9-6 MSY
AC 9-6 MSY

PVC
PVC
PVC
PVC

PVC/galv.
steel wire braiding/
PVC

12,5
12,5
12,5
12,5

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

12
12
12
12

272
272
272
272

48321
48322
48323
48324

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 20-6 M
AN 20-6 M
AP 20-6 M
AC 20-6 M

PVC
PVC
PVC
PVC

PETP-tape/
Cu-ground wire
bare 0,5 mm /
Alu-tape/PVC

12,4
12,4
12,4
12,4

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

12
12
12
12

186
186
186
186

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5
7,5

238
238
238
238
238

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

410
410
410
410

Multi-paired: 4 pairs (8 x 1,5 mm2) (L = stranded wires, conductor make-up 48 x 0,20 mm)
48106 Fe-CuNi (Ko)
L
AE 9-8 L
PVC
PVC
11,0
round
48107 SoNiCr-SoNi
K
AN 9-8 L
PVC
PVC
11,0
round
48108 SoPtRh-SoPt
S
AP 9-8 L
PVC
PVC
11,0
round
48325 Cu-CuNi (Ko)
U
AC 9-8 L
PVC
PVC
11,0
round
48485 Fe-CuNi
J
AF 9-8 L
PVC
PVC
11,0
round
48143
48144
48145
48326

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-8 LSY
AN 9-8 LSY
AP 9-8 LSY
AC 9-8 LSY

PVC
PVC
PVC
PVC

PVC/galv.
steel wire braiding/
PVC

14,0
14,0
14,0
14,0

round
round
round
round

Continuation

ThermoType
Core
Jacket/
Outer
Form TempeTempepair
insulation Armouring/

rature
rature
materials
Jacket
ca. mm
range of
range at
to
insulation
installation
DIN 43713
C
C
Single pair: 2 x 1,5 mm2 (L = stranded wires, conductor make-up 48 x 0,20 mm; M = solid conductor, diameter 1,38 mm)
48289 FE-CuNi (Ko)
L
AE 20 L
PVC
8,0
round
stationary:
PETP-tape/
48290 SoNiCr-SoNi
K
AN 20 L
PVC
8,0
round 10C
25C to +70C
Cu-ground wire
to
flexing:
bare 0,5 mm /
48291 SoPtRh-SoPt
S
AP 20 L
PVC
8,0
round
+80C
5C to +70C
Alu-tape/PVC
48292 Cu-CuNi (Ko)
U
AC 20 L
PVC
8,0
round
Thermopair Type

Part
No.

L = conductor of stranded wires


M = solid conductor
tin. = tinned
galv. = galvanized

L8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Compensating Cables
Thermopair
materials
to
DIN 43713

Type
Thermopair Type

Part
No.

Core
Jacket/
insulation Armouring/
Jacket

Outer
Form

ca. mm

Multi-paired: 5 pairs (10 x 1,5 mm2) (L = stranded wires, conductor make-up 48 x 0,20 mm)
48109 Fe-CuNi (Ko)
L
AE 9-10 L
PVC
PVC
13,0
round
48110 SoNiCr-SoNi
K
AN 9-10 L
PVC
PVC
13,0
round
48111 SoPtRh-SoPt
S
AP 9-10 L
PVC
PVC
13,0
round
48327 Cu-CuNi (Ko)
U
AC 9-10 L
PVC
PVC
13,0
round
48486 Fe-CuNi
J
AF 9-10 L
PVC
PVC
13,0
round

Temperature
range of
insulation
C

Temperature
range at
installation
C

Min.
bending
radius
..x
cable

Weight
ca.
kg/km

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5
7,5

284
284
284
284
284

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

475
475
475
475

Multi-paired: 6 pairs (12 x 1,5 mm2) (L = stranded wires, conductor make-up 48 x 0,20 mm; M = solid conductor, diameter 1,38 mm)
48112 Fe-CuNi (Ko)
L
AE 9-12 L
PVC
PVC
13,5
round
stationary:
48113 SoNiCr-SoNi
K
AN 9-12 L
PVC
PVC
13,5
round 10C
25C to +70C
48114 SoPtRh-SoPt
S
AP 9-12 L
PVC
PVC
13,5
round to
flexing:
48329 Cu-CuNi (Ko)
U
AC 9-12 L
PVC
PVC
13,5
round +80C
5C to +70C
48487 Fe-CuNi
J
AF 9-12 L
PVC
PVC
13,5
round

7,5
7,5
7,5
7,5
7,5

320
320
320
320
320

48330
48331
48332
48333

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-12 LS
AN 9-12 LS
AP 9-12 LS
AC 9-12 LS

PVC
PVC
PVC
PVC

PVC/galv.
steel wire
braiding

14,2
14,2
14,2
14,2

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

384
384
384
384

48149
48150
48151
48334

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-12 LSY
AN 9-12 LSY
AP 9-12 LSY
AC 9-12 LSY

PVC
PVC
PVC
PVC

PVC/galv.
steel wire braiding/
PVC

17,5
17,5
17,5
17,5

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

483
483
483
483

48335
48336
48337
48338

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-12 MSY
AN 9-12 MSY
AP 9-12 MSY
AC 9-12 MSY

PVC
PVC
PVC
PVC

PVC/galv.
steel wire braiding/
PVC

16,5
16,5
16,5
16,5

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

12
12
12
12

478
478
478
478

48339
48340
48341
48342

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 20-12 M
AN 20-12 M
AP 20-12 M
AC 20-12 M

PVC
PVC
PVC
PVC

PETP-tape/
Cu-ground wire
bare 0,5 mm /
Alu-tape/
PVC

16,3
16,3
16,3
16,3

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

12
12
12
12

362
362
362
362

48146
48147
48148
48328

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-10 LSY
AN 9-10 LSY
AP 9-10 LSY
AC 9-10 LSY

PVC
PVC
PVC
PVC

PVC/galv.
steel wire braiding/
PVC
-

16,5
16,5
16,5
16,5

round
round
round
round

Multi-paired: 7 pairs (14 x 1,5 mm2) (L = stranded wires, conductor make-up 48 x 0,20 mm)
48115
48116
48117
48343
48488

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)
Fe-CuNi

L
K
S
U
J

AE 9-14 L
AN 9-14 L
AP 9-14 L
AC 9-14 L
AF 9-14 L

PVC
PVC
PVC
PVC
PVC

PVC
PVC
PVC
PVC
PVC

14,5
14,5
14,5
14,5
14,5

round
round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
-5C to +70C

7,5
7,5
7,5
7,5
7,5

396
396
396
396
396

48152
48153
48154
48344

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-14 LSY
AN 9-14 LSY
AP 9-14 LSY
AC 9-14 LSY

PVC
PVC
PVC
PVC

PVC/galv.
steel wire braiding/
PVC

18,5
18,5
18,5
18,5

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

640
640
640
640

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)
Fe-CuNi

L
K
S
U
J

AE 9-16 L
AN 9-16 L
AP 9-16 L
AC 9-16 L
AF 9-16 L

PVC
PVC
PVC
PVC
PVC

PVC
PVC
PVC
PVC
PVC

15,1
15,1
15,1
15,1
15,1

round
round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5
7,5

419
419
419
419
419

48346
48347
48348
48349

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-16 LS
AN 9-16 LS
AP 9-16 LS
AC 9-16 LS

PVC
PVC
PVC
PVC

PVC/galv.
steel wire
braiding

16,1
16,1
16,1
16,1

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

495
495
495
495

48155
48156
48157
48350

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-16 LSY
AN 9-16 LSY
AP 9-16 LSY
AC 9-16 LSY

PVC
PVC
PVC
PVC

PVC/galv.
steel wire braiding/
PVC

19,3
19,3
19,3
19,3

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

623
623
623
623

48351
48352
48353
48354

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-16 MSY
AN 9-16 MSY
AP 9-16 MSY
AC 9-16 MSY

PVC
PVC
PVC
PVC

PVC/galv.
steel wire braiding/
PVC

18,7
18,7
18,7
18,7

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

12
12
12
12

616
616
616
616

48355
48356
48357
48358

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 20-16 M
AN 20-16 M
AP 20-16 M
AC 20-16 M

PVC
PVC
PVC
PVC

PETP-tape/
Cu-ground wire
bare 0,5 mm /
Alu-tape/
PVC

16,8
16,8
16,8
16,8

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

12
12
12
12

423
423
423
423
Continuation

Multi-paired: 8 pairs (16 x 1,5 mm2) (L = stranded wires, conductor make-up 48 x 0,20 mm; M = solid conductor, diameter 1,38 mm)
48118
48119
48120
48345
48489

L = conductor of stranded wires


M = solid conductor
tin. = tinned
galv. = galvanized

L9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Compensating Cables
Thermopair
materials
to
DIN 43713

Type
Thermopair Type

Part
No.

Core
Jacket/
insulation Armouring/
Jacket

Outer
Form

ca. mm

Temperature
range of
insulation
C

Temperature
range at
installation
C

Min.
bending
radius
..x
cable

Weight
ca.
kg/km

Multi-paired: 9 pairs (18 x 1,5 mm2) (L = stranded wires, conductor make-up 48 x 0,20 mm)
48121
48122
48123
48359
48490

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)
Fe-CuNi

L
K
S
U
J

AE 9-18 L
AN 9-18 L
AP 9-18 L
AC 9-18 L
AF 9-18 L

PVC
PVC
PVC
PVC
PVC

PVC
PVC
PVC
PVC
PVC

16,5
16,5
16,5
16,5
16,5

round
round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5
7,5

480
480
480
480
480

48158
48159
48160
48360

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-18 LSY
AN 9-18 LSY
AP 9-18 LSY
AC 9-18 LSY

PVC
PVC
PVC
PVC

PVC/galv.
steel wire braiding/
PVC

20,5
20,5
20,5
20,5

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

758
758
758
758

Multi-paired: 10 pairs (20 x 1,5 mm2) (L = stranded wires, conductor make-up 48 x 0,20 mm; M = solid conductor, diameter 1,38 mm)
48124 Fe-CuNi (Ko)
L
AE 9-20 L
PVC
PVC
16,7
round
7,5
stationary:
48125 SoNiCr-SoNi
K
AN 9-20 L
PVC
PVC
16,7
round 10C
7,5
25C to +70C
48126 SoPtRh-SoPt
S
AP 9-20 L
PVC
PVC
16,7
round to
7,5
flexing:
48361 Cu-CuNi (Ko)
U
AC 9-20 L
PVC
PVC
16,7
round +80C
7,5
5C to +70C
48491 Fe-CuNi
J
AF 9-20 L
PVC
PVC
16,7
round
7,5

520
520
520
520
520

48362
48363
48364
48365

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-20 LS
AN 9-20 LS
AP 9-20 LS
AC 9-20 LS

PVC
PVC
PVC
PVC

PVC/galv.
steel wire
braiding
-

17,7
17,7
17,7
17,7

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

613
613
613
613

48161
48162
48163
48366

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-20 LSY
AN 9-20 LSY
AP 9-20 LSY
AC 9-20 LSY

PVC
PVC
PVC
PVC

PVC/galv.
PVC/vzkt.
steel wire braiding/
StahldrahtPVC
PVC

20,9
20,9
20,9
20,9

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

752
752
752
752

48367
48368
48369
48370

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-20 MSY
AN 9-20 MSY
AP 9-20 MSY
AC 9-20 MSY

PVC
PVC
PVC
PVC

PVC/galv.
steel wire braiding/
PVC

20,3
20,3
20,3
20,3

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

744
744
744
744

PETP-tape/
48371 Fe-CuNi (Ko)
L
AE 20-20 M
PVC
20,3
round
12
stationary:
Cu-ground wire
48372 SoNiCr-SoNi
K
AN 20-20 M
PVC
20,3
round 10C
12
25C to +70C
bare 0,5 mm /
to
flexing:
48373 SoPtRh-SoPt
S
AP 20-20 M
PVC
20,3
round
12
Alu-tape/
+80C
5C to +70C
48374 Cu-CuNi (Ko)
U
AC 20-20 M
PVC
20,3
round
12
PVC
Multi-paired: 12 pairs (24 x 1,5 mm2) (L = stranded wires, conductor make-up 48 x 0,20 mm; M = solid conductor, diameter 1,38 mm)
48127 Fe-CuNi (Ko)
L
AE 9-24 L
PVC
PVC
19,0
round
7,5
stationary:
48128 SoNiCr-SoNi
K
AN 9-24 L
PVC
PVC
19,0
round 10C
7,5
25C to +70C
48129 SoPtRh-SoPt
S
AP 9-24 L
PVC
PVC
19,0
round to
7,5
flexing:
48375 Cu-CuNi (Ko)
U
AC 9-24 L
PVC
PVC
19,0
round +80C
7,5
5C to +70C
48492 Fe-CuNi
J
AF 9-24 L
PVC
PVC
19,0
round
7,5

542
542
542
542

48376
48377
48378
48379

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-24 LS
AN 9-24 LS
AP 9-24 LS
AC 9-24 LS

PVC
PVC
PVC
PVC

PVC/galv.
steel wire
braiding

20,2
20,2
20,2
20,2

round
round
round
round

48164
48165
48166
48380

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-24 LSY
AN 9-24 LSY
AP 9-24 LSY
AC 9-24 LSY

PVC
PVC
PVC
PVC

PVC/galv.
steel wire braiding/
PVC

24,2
24,2
24,2
24,2

48381
48382
48383
48384

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-24 MSY
AN 9-24 MSY
AP 9-24 MSY
AC 9-24 MSY

PVC
PVC
PVC
PVC

23,1
PVC/galv.
23,1
steel wire braiding/
23,1
PVC
23,1

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

738
738
738
738

round
round 10C
to
round
+80C
round

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

938
938
938
938

round
round
round
round

stationary:
25C to +70C
flexing:
5C to +70C

10C
to
+80C

10C
to
+80C

12
12
12
12

907
907
907
907

PETP-tape/
48385 Fe-CuNi (Ko)
L
AE 20-24 M
PVC
22,5
round
12
stationary:
Cu-ground wire
48386 SoNiCr-SoNi
K
AN 20-24 M
PVC
22,5
round 10C
12
25C to +70C
bare 0,5 mm /
to
flexing:
48387 SoPtRh-SoPt
S
AP 20-24 M
PVC
22,5
round
12
Alu-tape/
+80C
5C to +70C
48388 Cu-CuNi (Ko)
U
AC 20-24 M
PVC
22,5
round
12
PVC
Multi-paired: 16 pairs (32 x 1,5 mm2) (L = stranded wires, conductor make-up 48 x 0,20 mm; M = solid conductor, diameter 1,38 mm)
48389 Fe-CuNi (Ko)
L
AE 9-32 L
PVC
PVC
20,9
round
7,5
stationary:
48390 SoNiCr-SoNi
K
AN 9-32 L
PVC
PVC
20,9
round 10C
7,5
25C to +70C
48391 SoPtRh-SoPt
S
AP 9-32 L
PVC
PVC
20,9
round to
7,5
flexing:
48392 Cu-CuNi (Ko)
U
AC 9-32 L
PVC
PVC
20,9
round +80C
7,5
5C to +70C
48493 Fe-CuNi
J
AF 9-32 L
PVC
PVC
20,9
round
7,5

638
638
638
638

48393
48394
48395
48396

923
923
923
923

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-32 LS
AN 9-32 LS
AP 9-32 LS
AC 9-32 LS

PVC
PVC
PVC
PVC

PVC/galv.
steel wire
braiding

22,1
22,1
22,1
22,1

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

614
614
614
614
614

793
793
793
793
793

Continuation

12
12
12
12

L = conductor of stranded wires


M = solid conductor
tin. = tinned
galv. = galvanized

L 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Compensating Cables
Type

Core
Jacket/
insulation Armouring/
Jacket

Outer
Form

ca. mm

Temperature
range of
insulation
C

Temperature
range at
installation
C

Min.
bending
radius
..x
cable

Weight
ca.
kg/km

Multi-paired: 16 pairs (32 x 1,5 mm2) (L = stranded wires, conductor make-up 48 x 0,20 mm; M = solid conductor, diameter 1,38 mm)
48397 Fe-CuNi (Ko)
L
AE 9-32 LSY
PVC
26,1
round
7,5
stationary:
PVC/galv.
48398 SoNiCr-SoNi
K
AN 9-32 LSY
PVC
26,1
round 10C
7,5
25C to +70C
to
steel wire braiding/
flexing:
48399 SoPtRh-SoPt
S
AP 9-32 LSY
PVC
26,1
round
7,5
+80C
PVC
5C to +70C
48400 Cu-CuNi (Ko)
U
AC 9-32 LSY
PVC
26,1
round
7,5

1141
1141
1141
1141

48401
48402
48403
48404

1130
1130
1130
1130

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-32 MSY
AN 9-32 MSY
AP 9-32 MSY
AC 9-32 MSY

PVC
PVC
PVC
PVC

PVC/galv.
steel wire braiding/
PVC

25,3
25,3
25,3
25,3

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

12
12
12
12

PETP-tape/
48405 Fe-CuNi (Ko)
L
AE 20-32 M
PVC
25,1
round
12
stationary:
10C
Cu-ground wire
48406 SoNiCr-SoNi
K
AN 20-32 M
PVC
25,1
round
12
25C to +70C
to
bare 0,5 mm /
flexing:
48407 SoPtRh-SoPt
S
AP 20-32 M
PVC
25,1
round +80C
12
Alu-tape/
5C to +70C
48408 Cu-CuNi (Ko)
U
AC 20-32 M
PVC
25,1
round
12
PVC
Multi-paired: 18 pairs (36 x 1,5 mm2) (L = stranded wires, conductor make-up 48 x 0,20 mm; M = solid conductor, diameter 1,38 mm)
48130 FE-CuNi (Ko)
L
AE 9-36 L
PVC
PVC
22,1
round
7,5
stationary:
48132 SoNiCr-SoNi
K
AN 9-36 L
PVC
PVC
22,1
round 10C
7,5
25C to +70C
48133 SoPtRh-SoPt
S
AP 9-36 L
PVC
PVC
22,1
round to
7,5
flexing:
48409 Cu-CuNi (Ko)
U
AC 9-36 L
PVC
PVC
22,1
round +80C
7,5
5C to +70C
48494 Fe-CuNi
J
AF 9-36 L
PVC
PVC
22,1
round
7,5

847
847
847
847
904
904
904
904
904

48410
48411
48412
48413

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-36 LS
AN 9-36 LS
AP 9-36 LS
AC 9-36 LS

PVC
PVC
PVC
PVC

PVC/galv.
steel wire
braiding

23,3
23,3
23,3
23,3

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

1040
1040
1040
1040

48167
48169
48170
48414

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-36 LSY
AN 9-36 LSY
AP 9-36 LSY
AC 9-36 LSY

PVC
PVC
PVC
PVC

PVC/galv.
steel wire braiding/
PVC

27,3
27,3
27,3
27,3

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

1268
1268
1268
1268

48415
48416
48417
48418

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-36 MSY
AN 9-36 MSY
AP 9-36 MSY
AC 9-36 MSY

PVC
PVC
PVC
PVC

PVC/galv.
steel wire braiding/
PVC

26,1
26,1
26,1
26,1

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

12
12
12
12

1232
1232
1232
1232

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

12
12
12
12

944
944
944
944

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

PETP-tape/
48419 Fe-CuNi (Ko)
L
AE 20-36 M
PVC
26,0
round
Cu-ground wire
48420 SoNiCr-SoNi
K
AN 20-36 M
PVC
26,0
round
bare 0,5 mm /
48421 SoPtRh-SoPt
S
AP 20-36 M
PVC
26,0
round
Alu-tape/
48422 Cu-CuNi (Ko)
U
AC 20-36 M
PVC
26,0
round
PVC
Multi-paired: 19 pairs (38 x 1,5 mm2) (L = stranded wires, conductor make-up 48 x 0,20 mm)
48134 Fe-CuNi (Ko)
L
AE 9-38 L
PVC
PVC
22,5
round
48135 SoNiCr-SoNi
K
AN 9-38 L
PVC
PVC
22,5
round
48136 SoPtRh-SoPt
S
AP 9-38 L
PVC
PVC
22,5
round
48423 Cu-CuNi (Ko)
U
AC 9-38 L
PVC
PVC
22,5
round

7,5
7,5
7,5
7,5

937
937
937
937

48171 Fe-CuNi (Ko)


L
AE 9-38 LSY
PVC
26,5
round
7,5
stationary:
PVC/galv.
48172 SoNiCr-SoNi
K
AN 9-38 LSY
PVC
26,5
round 10C
7,5
25C
to
+70C
steel wire braiding/
to
flexing:
48173 SoPtRh-SoPt
S
AP 9-38 LSY
PVC
26,5
round
7,5
PVC
+80C
5C to +70C
48424 Cu-CuNi (Ko)
U
AC 9-38 LSY
PVC
26,5
round
7,5
Multi-paired: 20 pairs (40 x 1,5 mm2) (L = stranded wires, conductor make-up 48 x 0,20 mm; M = solid conductor, diameter 1,38 mm)
48425 Fe-CuNi (Ko)
L
AE 9-40 L
PVC
PVC
24,1
round
7,5
stationary:
48426 SoNiCr-SoNi
K
AN 9-40 L
PVC
PVC
24,1
round 10C
7,5
25C to +70C
to
flexing:
48427 SoPtRh-SoPt
S
AP 9-40 L
PVC
PVC
24,1
round
7,5
+80C
5C to +70C
48428 Cu-CuNi (Ko)
U
AC 9-40 L
PVC
PVC
24,1
round
7,5

1340
1340
1340
1340

48429
48430
48431
48432

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-40 LS
AN 9-40 LS
AP 9-40 LS
AC 9-40 LS

PVC
PVC
PVC
PVC

PVC/galv.
steel wire
braiding

25,3
25,3
25,3
25,3

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

1200
1200
1200
1200

48433
48434
48435
48436

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-40 LSY
AN 9-40 LSY
AP 9-40 LSY
AC 9-40 LSY

PVC
PVC
PVC
PVC

PVC/galv.
steel wire braiding/
PVC

29,3
29,3
29,3
29,3

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

1446
1446
1446
1446

48437
48438
48439
48440

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 9-40 MSY
AN 9-40 MSY
AP 9-40 MSY
AC 9-40 MSY

PVC
PVC
PVC
PVC

PVC/galv.
steel wire braiding/
PVC

28,0
28,0
28,0
28,0

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

12
12
12
12

1381
1381
1381
1381

48441
48442
48443
48444

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 20-40 M
AN 20-40 M
AP 20-40 M
AC 20-40 M

PVC
PVC
PVC
PVC

PETP-tape/
Cu-ground wire
bare 0,5 mm /
Alu-tape/
PVC

26,0
26,0
26,0
26,0

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

12
12
12
12

1001
1001
1001
1001

1032
1032
1032
1032

Continuation

Thermopair
materials
to
DIN 43713

Thermopair Type

Part
No.

L = conductor of stranded wires


M = solid conductor
tin. = tinned
galv. = galvanized

L 11
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Compensating Cables
Thermopair
materials
to
DIN 43713

Type
Thermopair Type

Part
No.

Core
insulation

Jacket/
Armouring/
Jacket

Single pair: 2 x 0,22 mm2 (stranded wires, conductor make-up 7 x 0,20 mm)
48200 FE-CuNi (Ko)
L
AE 1 L
PVC
48201 SoNiCr-SoNi
K
AN 1 L
PVC
48202 SoPtRh-SoPt
S
AP 1 L
PVC
48460 Cu-CuNi (Ko)
U
AC 1 L
PVC
Single pair: 2 x 0,22 mm2 (stranded wires, conductor make-up 7 x 0,20 mm)
48203 Fe-CuNi (Ko)
L
AE 9-022
PVC
PVC
48204 SoNiCr-SoNi
K
AN 9-022
PVC
PVC
48205 SoPtRh-SoPt
S
AP 9-022
PVC
PVC
48461 Cu-CuNi (Ko)
U
AC 9-022
PVC
PVC

Outer
Form

ca. mm

Temperature
range of
insulation
C

Temperature
range at
installation
C

Min.
bending
radius
..x
cable

Weight
ca.
kg/km

1,0
1,0
1,0
1,0

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

10
10
10
10

4,0
4,0
4,0
4,0

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

22
22
22
22

48206
48207
48208
48462

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 5-022
AN 5-022
AP 5-022
AC 5-022

PVC
PVC
PVC
PVC

PETP-tape/
Cu-solid wire braid.
tinned/
PVC

4,9
4,9
4,9
4,9

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

31
31
31
31

48463
48464
48465
48466

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 15-022
AN 15-022
AP 15-022
AC 15-022

glass filam.
glass filam.
glass filam.
glass filam.

Silicone
Silicone
Silicone
Silicone

3,4
3,4
3,4
3,4

round
round
round
round

40C
to
+200C

stationary:
25C to +180C
flexing:
25C to +180C
(short time +200C)

7,5
7,5
7,5
7,5

16
16
16
16

48209
48210
48211
48467

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE 15-G 022
AN 15-G 022
AP 15-G 022
AC 15-G 022

glass filam.
glass filam. Silicone/
glass filam. glass filam.
glass filam.

3,9
3,9
3,9
3,9

round
round
round
round

40C
to
+200C

stationary:
25C to +180C
flexing:
25C to +180C
(short time +200C)

7,5
7,5
7,5
7,5

22
22
22
22

48212 Fe-CuNi (Ko)


L
AE (GI-SIL-GI-S)
glass filam. Silicone/
48213 SoNiCr-SoNi
K
AN (GI-SIL-GI-S)
glass filam. glass filament/
48214 SoPtRh-SoPt
S
AP (GI-SIL-GI-S)
glass filam. galv. steel wire
48468 Cu-CuNi (Ko)
U
AC (GI-SIL-GI-S)
glass filam. braiding
Single pair: 2 x 0,5 mm2 (stranded wires, conductor make-up 16 x 0,20 mm)
48215 Fe-CuNi (Ko)
L
AE (GI-SIL)
glass filam. Silicone
48216 SoNiCr-SoNi
K
AN (GI-SIL)
glass filam. Silicone
48217 SoPtRh-SoPt
S
AP (GI-SIL)
glass filam. Silicone
48469 Cu-CuNi (Ko)
U
AC (GI-SIL)
glass filam. Silicone
Single pair: 2 x 0,75 mm2 (stranded wires, conductor make-up 24 x 0,20 mm)
48218 Fe-CuNi (Ko)
L
AE (PVC-PVC)
PVC
PVC
48219 SoNiCr-SoNi
K
AN (PVC-PVC)
PVC
PVC
48220 SoPtRh-SoPt
S
AP (PVC-PVC)
PVC
PVC
48470 Cu-CuNi (Ko)
U
AC (PVC-PVC)
PVC
PVC
Multi-paired: 4 x 0,22 mm2 (stranded wires, conductor make-up 7 x 0,20 mm)
48221 Fe-CuNi (Ko)
L
AE (PVC-PVC)
PVC
PVC
48222 SoNiCr-SoNi
K
AN (PVC-PVC)
PVC
PVC
48223 SoPtRh-SoPt
S
AP (PVC-PVC)
PVC
PVC
48471 Cu-CuNi (Ko)
U
AC (PVC-PVC)
PVC
PVC

5,0
5,0
5,0
5,0

round
round
round
round

40C
to
+200C

stationary:
25C to +180C
flexing:
25C to +180C
(short time +200C)

7,5
7,5
7,5
7,5

25
25
25
25

4,6
4,6
4,6
4,6

round
round
round
round

40C
to
+200C

stationary:
25C to +200C
flexing:
25C to +200C

7,5
7,5
7,5
7,5

18
18
18
18

6,0
6,0
6,0
6,0

round
round
round
round

10C
to
+80C

stationary:
25C to +70C
flexing:
5C to +70C

7,5
7,5
7,5
7,5

25
25
25
25

6,0
6,0
6,0
6,0

round
round
round
round

10C
to
+80C

stationary:
20C to +80C
flexing:
5C to +80C

7,5
7,5
7,5
7,5

33
33
33
33

48224
48225
48226
48472

6,0
6,0
6,0
6,0

round
round
round
round

10C
to
+80C

stationary:
20C to +80C
flexing:
5C to +80C

7,5
7,5
7,5
7,5

37
37
37
37

6,0
6,0
6,0
6,0

round
round
round
round

40C
to
+200C

stationary:
25C to +180C
flexing:
25C to +180C

7,5
7,5
7,5
7,5

35
35
35
35

7,8
7,8
7,8
7,8

round
round
round
round

60C
to
+180C

stationary:
25C to +180C
flexing:
25C to +180C
(short time +200C)

7,5
7,5
7,5
7,5

11,8
11,8
11,8
11,8

Fe-CuNi (Ko)
SoNiCr-SoNi
SoPtRh-SoPt
Cu-CuNi (Ko)

L
K
S
U

AE (PVCCPVC)
AN (PVCCPVC)
AP (PVCCPVC)
AC (PVCCPVC)

PVC
PVC
PVC
PVC

galv.
Cu-braiding/
PVC-jacket

48227 Fe-CuNi (Ko)


L
AE (GI-SIL)
glass filam. Silicone
48228 SoNiCr-SoNi
K
AN (GI-SIL)
glass filam. Silicone
48229 SoPtRh-SoPt
S
AP (GI-SIL)
glass filam. Silicone
48473 Cu-CuNi (Ko)
U
AC (GI-SIL)
glass filam. Silicone
Multi-paired: 4 x 1,5 mm2 (stranded wires, conductor make-up 48 x 0,20 mm)
48474 Fe-CuNi (Ko)
L
AE 11-4 Lr
Silicone
glass filament/
48475 SoNiCr-SoNi
K
AN 11-4 Lr
Silicone
galv. steel wire
48476 SoPtRh-SoPt
S
AP 11-4 Lr
Silicone
braiding
48477 Cu-CuNi (Ko)
U
AC 11-4 Lr
Silicone

L = conductor of stranded wires


M = solid conductor
tin. = tinned
galv. = galvanized

L 12
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Coaxial Cables

M1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Coaxial Cables

Coaxial cables are used in all areas of the high


frequency transmission technology, for example
in medicine, military or in communication sectors.
Because of the wide spectrum of coaxial and video
or TV cables, which HELUKABEL has in stock, most
requirements are covered. Naturally we also offer
special constructions for you.
HELUKABEL supply RG-coaxial cables or RG-multi
coaxial cables according to the american military
standard MIL-C-17.
The coaxial cables for satellite receivers and
TV aerials as well as video cables are designed
according to the respective specied standards.

M2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description
RG-Coaxial Cables................................................................................................................................................................................
RG-Coaxial Cables................................................................................................................................................................................
RG-Coaxial Cables................................................................................................................................................................................
Halogen-Free RG-Coaxial Cables........................................................................................................................................................
CATV-Cables,with alu- or copper foil and braiding.........................................................................................................................................

SAT-Coaxial Cables,up to 2150 MHz, for satellite-receivers, double screened.........................................................................................................


Multimedia-Coaxial Cables,SAT 1,0/4,6GH, up to 2400MHz, for digital-tv, double screened, screening efficieny >90dB................................................

SAT-Coaxial Cables,for digital-tv, screening efficieny >90dB / >95dB, for satellite-receivers, double screened..............................................................
RGB-COAX-CY / RGB-COAX-(St)Y,transmission cables for colour monitor.......................................................................................................

Page
M 4
M 5
M 6
M 7
M 8
M 9

M 10
M 11
M 12

M3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

RG-Coaxial Cables



Type RG.../U
Part no.

Cable structure
Inner conductor diameter mm
Insulation mm
Outer conductor
Outer jacket
Min. bending radiusapprox. mm
Temperature range C
Copper weight kg/km
Outer approx. mm
Weightapprox. kg/km

Electrical characteristics
Impedance (Ohm)
Frequency range
f (max.) GHz
Propagation velocity v/c
Attenuationat 20 C
(dB/100m)
100 MHz
200 MHz
500 MHz
800 MHz
1000 MHz
1350 MHz
1750 MHz
Capacitance pF/m
Rel. velocity of propagation %
Insulation resistance
MOhm x km min.
Loop resistance
max. (Ohm/km)
Nominal peak voltage kVs
Dielectric strength
50 Hz kVeff

6
40001

8
40013

11
40002

58
40003

59
40004

62
40005

1 x 0,72
Steel/copper, bare
4,7  PE
2 braids
Silvered copper
Copper, bare
PVC
40
-35to+80
67,0
8,4
115

7 x 0,72
Copper, bare
6,4  PE
Braid
Copper, bare
PVC
50
-35to+80
62,0
9,5
128

7 x 0,4
Tinned copper
7,3  PE
Braid
Copper, bare
PVC
50
-35to+80
58,0
10,3
140

19 x 0,18
Tinned copper
2,95  PE
Braid
Tinned copper
PVC
25
-35to+80
21,0
4,95
38

1 x 0,6
Steel/copper, bare
3,7  PE
Braid
Copper, bare
PVC
30
-35to+80
26,0
6,2
57

1 x 0,65
Steel/copper, bare
3,7  PE, hollow
Braid
Copper, bare
PVC
30
-35to+80
26,0
6,15
52

75 3

50 2

75 3

50 2

75 3

93 5

3
0,66

3
0,66

3
0,66

3
0,66

3
0,66

3
0,83

8,8
13,5
21
27,5
67
67

8
10,8
17
25
26,5
30,6
35
101
66

7,5
11
18,5
24
30
67
67

17
24
39
51
56
101
67

11,5
16,5
27
35
41
67
67

10,5
15
24,5
32,5
35
42,5
83

10

10

10

10

10

10

110
2,8

11
5,1

23
5,2

53
2,5

171
3,5

155
1,1

9,5

10

Dimensions and specifications may be changed without prior notice. (RM01)




Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties
of lacquers.
RG-Coaxial types are in accordance with US-Military specifications MIL-C-17.
RG/U: R=Radio, G=Guide, U=Utility


Application
Coaxial cables are used in high frequency transmission, especially for transmitters and receivers, computers, radio and TV transmissions. The
varied mechanical, thermal and electronic properties of Coaxial cables mean that they can be used up into the GHz levels, as per cable type.

M4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

RG-Coaxial Cables



Type RG.../U
Part no.

Cable structure
Inner conductor diameter mm

71
40006

174
40197

178
40007

179
40008

180
40009

187
40010

213
40012

1 x 0,65
Steel/copper, bare

7 x 0,16
Steel/copper, bare

3,7  PE, hollow


2 braids
Copper, bare
Tinned copper
PE
30
-50to+70
48,0
6,2
62

1,52  PE
Braid
Tinned copper
PVC
15
-35to+80
7,0
2,8
11

7 x 0,1
Steel/copper,
silvered
1,6  PTFE
Braid
Silvered copper
FEP
15
-55to+200
7,3
2,54
16

7 x 0,1
Steel/copper,
silvered
2,6  PTFE
Braid
Silvered copper
FEP
25
-55to+200
11,0
3,7
28

7 x 0,1
Steel/copper,
silvered
1,6  PTFE
Braid
Silvered copper
PFA
15
-55to+260
8,5
2,65
17

7 x 0,75
Copper, bare

Insulation mm
Outer conductor

7 x 0,1
Steel/copper,
silvered
0,86  PTFE
Braid
Silvered copper
FEP
10
-55to+200
6,4
1,8
8

93 3

50 2

50 2

75 3

95 5

75 3

50 2

3
0,83

1
0,66

3
0,7

3
0,7

3
0,7

3
0,7

3
0,66

10,5
15
24,5
32,5
42,5
83

30
45
73
93
101
70

43
62
102
134
93
70

28
41
69
92
63
70

20
33
50
70

28
41
69
92
64
70

7
10,2
17
23
101
100

Outer jacket
Min. bending radiusapprox. mm
Temperature range C
Copper weight kg/km
Outer approx. mm
Weightapprox. kg/km

Electrical characteristics
Impedance (Ohm)
Frequency range
f (max.) GHz
Propagation velocity v/c
Attenuationat 20C
(dB/100m)
100 MHz
200 MHz
500 MHz
800 MHz
Capacitance pF/m
Rel. velocity of propagation %
Insulation resistance
MOhm x km min.
Loop resistance
max. (Ohm/km)
Nominal peak voltage kVs
Dielectric strength
50 Hz kVeff

10

10

10

10

10

10

7,24  PE
Braid
Copper, bare
PVC
50
-35to+80
79,0
10,3
159

10

136
1,5

360
1,1

860
1,1

840
1,3

840
1,6

840
1,3

10
5,2

10

Dimensions and specifications may be changed without prior notice. (RM01)




Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties
of lacquers.
The colour at FEP and PFA outer jacket is black or transparent as per production outlet.
RG-Coaxial types are in accordance with US-Military specifications MIL-C-17.
RG/U: R=Radio, G=Guide, U=Utility


Application
Coaxial cables are used in high frequency transmission, especially for transmitters and receivers, computers, radio and TV transmissions. The
varied mechanical, thermal and electronic properties of Coaxial cables mean that they can be used up into the GHz levels, as per cable type.

M5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

RG-Coaxial Cables



Type RG.../U
Part no.

Cable structure
Inner conductor diameter mm
Insulation mm
Outer conductor
Outer jacket
Min. bending radiusapprox. mm
Temperature range C
Copper weight kg/km
Outer approx. mm
Weightapprox. kg/km

Electrical characteristics
Impedance (Ohm)
Frequency range
f (max.) GHz
Propagation velocity v/c
Attenuationat 20C
(dB/100m)
100 MHz
200 MHz
500 MHz
800 MHz
Capacitance pF/m
Rel. velocity of propagation %
Insulation resistance
MOhm x km min.
Loop resistance
max. (Ohm/km)
Nominal peak voltage kVs
Dielectric strength
50 Hz kVeff

214
40011

215
40198

216
40199

217
40200

218
40201

223
40202

316
40203

7 x 0,75
Silvered copper
7,24  PE
2 braids
2x silvered copper
PVC
50
-35to+80
119,0
10,8
198

7 x 0,75
Copper, bare
7,24  PE
Braid
Copper, bare
PVC
70
-35to+80
148,0
10,3
300

7 x 0,4
Tinned copper
7,24  PE
2 braids
Copper, bare
PVC
50
-35to+80
107,0
10,8
176

1 x 2,7
Copper, bare
9,4  PE
2 braids
Copper, bare
PVC
70
-35to+80
187,0
13,84
300

1 x 4,95
Copper, bare
17,3  PE
Braid
Copper, bare
PVC
110
-35to+80
348,0
22,1
710

1 x 0,9
Silvered copper
2,95  PE
2 braids
2x silvered copper
PVC
25
-35to+80
42,0
5,38
60

7 x 0,17
Steel/copper, silvered
1,52  PTFE
Braid
Silvered copper
PTFE/ alt. FEP
15
-55to+200
8,5
2,5
15

50 2

50 2

75 3

50 2

50 2

50 2

50 2

11
0,66

3
0,66

3
0,66

3
0,66

3
0,66

3
0,66

3
0,66

7
10,2
17
23
101
67

7
10,2
17
23
101
100

7,5
11
18,5
24
67
100

4,8
7,1
12,3
16,8
101
100

2,9
4,5
8,1
11,2
101
100

17
23
38
50
101
67

28
40
68
90
95
70

10

10
5,2

10
5

21
5

5
7

2
11

36
1,9

310
1,2

10

10

10

10

15

10

10

10

10

10

10

Dimensions and specifications may be changed without prior notice. (RM01)




Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties
of lacquers.
The colour outer jacket at PTFE is black or transparent as per production outlet.
RG-Coaxial types are in accordance with US-Military specifications MIL-C-17.
RG/U: R=Radio, G=Guide, U=Utility


Application
Coaxial cables are used in high frequency transmission, especially for transmitters and receivers, computers, radio and TV transmissions. The
varied mechanical, thermal and electronic properties of Coaxial cables mean that they can be used up into the GHz levels, as per cable type.

M6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Halogen-Free RG-Coaxial Cables





Type RG.../U
Part no.

Cable structure
Inner conductor diameter mm
Insulation mm
Outer conductor
Outer jacket
Min. bending radiusapprox. mm
Temperature range C
Copper weight kg/km
Outer approx. mm
Weightapprox. kg/km

Electrical characteristics
Impedance (Ohm)
Frequency range
f (max.) GHz
Propagation velocity v/c
Attenuationat 20C
(dB/100m)
3 MHz
10 MHz
100 MHz
200 MHz
500 MHz
800 MHz
Capacitance pF/m
Rel. velocity of propagation %
Insulation resistance
MOhm x km min.
Loop resistance
max. (Ohm/km)
Nominal peak voltage kVs
Dielectric strength
50 Hz kV eff.

11
40190

58
40191

59
40192

62
40193

71
40194

213
40195

214
40196

7 x 0,4
Tinned copper
7,3  PE
Braid
Copper, bare
HM2
50
-35to+80
58,0
10,3
144

19 x 0,18
Tinned copper
2,95  PE
Braid
Tinned copper
HM2
25
-35to+80
21,0
5,4
38

1 x 0,6
Steel/copper, bare
3,7  PE
Braid
Copper, bare
HM2
30
-35to+80
26,0
6,4
57

1 x 0,65
Steel/copper, bare
3,7  PE, hollow
Braid
Copper, bare
HM2
30
-35to+80
26,0
6,4
54

1 x 0,65
Steel/copper, bare
3,7  PE, hollow
2 braids
Copper, bare
Tinned copper
HM2
30
-50to+70
48,0
6,9
64

7 x 0,75
Copper, bare
7,24  PE
Braid
Copper, bare
HM2
50
-35to+80
79,0
10,3
155

7 x 0,75
Silvered copper
7,24  PE
2 braids
2x silvered copper
HM2
50
-35to+80
119,0
10,8
203

75 3

50 2

75 3

93 5

93 3

50 2

50 2

3
0,66

3
0,66

3
0,66

3
0,85

3
0,85

3
0,66

11
0,66

1,3
2,4
7,8
11,3
18,7
23,4
68
67

2,9
5,3
17
24,4
39,2
47,8
0
67

2
3,8
12,2
17,6
27,2
35,2
68
67

2
3,7
12
17,3
24,7
34,6
42,5
43

2
3,7
12,5
17,3
24,7
34,6
42,5
43

1,2
2,3
7,5
10,9
17,2
22,6
101
101

1,2
2,3
7,5
10,9
17,2
22,6
101
101

10

10

10

10

10

10

10

23
5

53
1,9

171
2,3

155
0,75

136
0,75

10
5

10
5

10

10

10

Dimensions and specifications may be changed without prior notice. (RM01)




Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties
of lacquers.
H-outer jacket = halogen-free material (HM2)
RG-Coaxial types are in accordance with US-Military specifications MIL-C-17.
RG/U: R=Radio, G=Guide, U=Utility
FRNC = Flame Retardant Non-Corrosive


Application
Coaxial cables are used in high frequency transmission, especially for transmitters and receivers, computers, radio and TV transmissions
where no flame propagation under behaviour in fire is permitted. The varied mechanical, thermal and electronic properties of Coaxial cables
mean that they can be used up into the GHz levels, as per cable type.

M7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

CATV-Cables with alu- or copper foil and braiding





used as
Type
Part no.

Cable structure
Inner conductor diameter mm
Insulation mm
Outer conductor

Outer jacket
Jacket colour
Outer approx. mm
Min. bending radiusapprox. mm
Strain/suspending wire N
Weightapprox. kg/km

Electrical characteristics
Impedance (Ohm)
Capacitance pF/m
Propagation velocity v/c
Attenuationat 20C
(dB/100m)
100 MHz
200 MHz
500 MHz
800 MHz
950 MHz
1350 MHz
1750 MHz
2050 MHz
Structural return loss min. (dB) between
30 and 300 MHz
300 and 600 MHz
600 and 960 MHz
960 and 1750 MHz

DC resistanceat 20C
Inner conductormax. Ohm/km
Outer conductormax. Ohm/km

Screening efficiency (dB)
50 and 100 MHz
100 and 500 MHz
500 and 1000 MHz
1000 and 2050 MHz

Post office approved

0.7/4.4
ALG
40135

Underground
1.1/7.3
ALG
40139

Outdoor span
1.1/7.3
ALG-T
40140

Underground
1.8/11.5
FG
40141

Underground
A-2YK2Y1
iKx 1.1/7.3
40142

Underground
A-2Y0K2Y1
nKx 2.2/8.8
40143

Underground
A-2Y0K2Y1
qKx 3.3/13.5
40144

Underground
A-2Y0K2Y1
sKx 4.9/19.4
40179

0,7
Copper, bare
4,4  PE
Polyester foil
coated with
aluminium on
both sides
Braid
PVC
white
6,6
35
44

1,1
Copper, bare
7,3  PE
Polyester foil
coated with
aluminium on
both sides
Braid
PE
black
10,5
100
98

1,1
Copper, bare
7,3  PE
Polyester foil
coated with
aluminium on
both sides
Braid
PE
black
2,8
150
5500
177

1,8
Copper, bare
11,5  PE
Copper tape

1,1
Copper, bare
7,3  PE
Copper tube,
welded

2,2
Copper, bare
8,8  PE, hollow
Copper tube,
welded

3,3
Copper, bare
13,5  PE, hollow
Copper tube,
welded

4,9
Copper, bare
19,4  PE, hollow
Copper tube,
welded

Braid
PE
black
15,0
150
218

PE
black
11,0
160
142

PE
black
12,5
200
183

PE
black
17,0
300
347

PE
black
24,4
400
500

75 3
67
0,66

75 3
67
0,66

75 3
67
0,66

75 3
67
0,66

75 2
65
0,66

75 2
51
0,88

75 1
51
0,88

75 1
50
0,89

9
12
21,2
27,5
30,5
37
43
47,5

5,2
7,3
12,6
16,8
18,8
23
27,7
30,2

5,2
7,3
12,6
16,8
18,8
23
27,7
30,2

3,5
5,2
9
12
13
-

5,4
7,9
12,9
17,3
18,9
-

2,8
4
6,6
8,4
9,3
-

1,9
2,7
4,4
5,7
6,3
-

1,3
1,9
3,1
4,1
4,4
-

30
30
25
23

32
32
30
27

32
32
30
27

30
30
28
25

26
23
21
-

26
23
21
-

28
25
23
-

28
25
23
-

47
23

18,5
11

18,5
11

7,3
6,5

22
3,1

5,6
3

2,5
2

1
1

75
75
75
75

80
85
85
78

80
85
85
78

80
85
85
80

110
110
110
110

110
110
110
110

110
110
110
110

110
110
110
110

G670009A

G670011A

G622015B

G622010B

Dimensions and specifications may be changed without prior notice. (RM01)




Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties
of lacquers.
AL=Aluminium, ALPR=PolyesterfoilcoatedwithAluminiumonbothsides
BK-cable=bandwidthcommunicationcable, Cu=Copper, CuR=Cu-tubewelded, CuW=Copperweld, F=Foil, G=Braid, PE=Polyethylene,
PEH=Polyethyleneair-spaceinsulation, PVC=Polyvinylchloride

M8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SAT-Coaxial Cables up to 2150 MHz, for satellite-receivers, double screened





Type
Part no.

Cable structure
Inner conductor diameter mm
Insulation mm
Core colours
Outer conductor

Outer jacket
Jacket colour
Outer approx. mm
Min. bending radiusapprox. mm
Weightapprox. kg/km

Electrical characteristics
Impedance (Ohm)
Capacitance pF/m
Propagation velocity v/c
Attenuationat 20C
(dB/100m)
100 MHz
200 MHz
500 MHz
800 MHz
950 MHz
1350 MHz
1750 MHz
2050 MHz
2150 MHz
Structural return loss min. (dB) between
30 and 300 MHz
300 and 600 MHz
600 and 960 MHz
960 and 2050 MHz

DC resistanceat 20C
Inner conductormax. Ohm/km
Outer conductormax. Ohm/km
Max. nominal voltage (V)

Screening efficiency (dB)
50 and 100 MHz
100 and 500 MHz
500 and 1000 MHz
1000 and 2050 MHz

Post office approved
Copper weight kg/km

1.1/5.0 ALG
40150

1.65/7.2 ALG
40151

SAT-MINI 1
40159

DUO 2x0.7/2.9
40168

QUADRO 4x0.7/2.9
40169

1,1  Tinned copper


5  Cell PE
Polyester foil coated with
aluminium on both sides
Braid
PVC
white
6,8
40
49

1,6  Copper, bare


7,2  Cell PE
Polyester foil coated with
aluminium on both sides
Braid
PE
black
10,1
60
81

0,8  Copper, bare


3,5  Cell PE
Polyester foil coated with
aluminium on both sides
Braid
PVC
white
5,4 x 10,8
40
62

0,65  Copper, bare


3  Cell PE
Polyester foil coated with
aluminium on both sides
Braid
PVC
white
8,6 x 4,3
35
40

0,65  Copper, bare


3  Cell PE
Polyester foil coated with
aluminium on both sides
Braid
PVC
white
20,0 x 4,3
80
82

75 3
55
0,82

75 3
55
0,82

75 3
55
0,82

75 3
55
0,8

75 3
55
0,8

5
7,3
13
17,2
19,5
23,5
27,6
30
31

3,7
5,1
9
11,8
13,6
16,8
19,7
22
22,5

8
11,5
18,5
23,5
25,5
31
35,5
39,5
43

8,9
13,5
22
28
31,5
37
42,3
45,9
50,4

8,9
13,5
22
28
31,5
37
42,3
45,9
50,4

28
28
26
24

31
30
30
28

27
25
20
20

20
17
17
-

20
18
15
-

18
20
-

9
12
-

36
28
-

110
22
-

52
26
-

75
75
75
75

80
85
85
78

78
78
75
75

75
75
75
75

75
75
75
75

G670010A
10,0

G622016B
35,0

30,0

16,0

32,0

Dimensions and specifications may be changed without prior notice. (RM01)




Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties
of lacquers.
AL=Aluminium, ALPR=PolyesterfoilcoatedwithAluminiumonbothsides
Cu=Copper, CuW=Copperweld, F=Foil, G=Braid, PE=Polyethylene, PEH=Polyethyleneair-spaceinsulation, PVC=Polyvinylchloride, vz=tinned

M9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Multimedia-Coaxial Cables SAT 1,0/4,6GH, up to 2400MHz, for digital-tv,


double screened, screening efficieny >90dB



used as
Type
Part no.

Cable structure
Inner conductor diameter mm
Insulation mm
Outer conductor
Outer jacket
Jacket colour
Outer approx. mm
Approv. bending radiusapprox. mm
Weightapprox. kg/km

Electrical characteristics
Impedance (Ohm)
Capacitance pF/m
Propagation velocity v/c
Attenuationat 20C
(dB/100m)
100 MHz
200 MHz
450 MHz
600 MHz
800 MHz
1000 MHz
1750 MHz
2050 MHz
2400 MHz
Structural return loss min. (dB) between
30 and 300 MHz
300 and 600 MHz
600 and 960 MHz
960 and 1750 MHz
1750 and 2400 MHz

DC resistanceat 20C
Inner conductormax. Ohm/km
Outer conductormax. Ohm/km
Max. nominal voltage (V)

Screening efficiency (dB)
Copper weight kg/km

inner/outer
1.0/4.6 GH-Y
40176

Underground
1.0/4.6 GH-2Y
40177

Safety zones
1.0/4.6 GH-FRNC
40178

1  Copper with skin


4,6  Cell polyethylene with skin and
PIB coating
Polyester foil coated with aluminium
on both sides
PVC
white
6,6
45
40

1  Copper with skin


4,6  Cell polyethylene with skin and
PIB coating
Polyester foil coated with aluminium
on both sides
PE
black
6,6
45
40

1  Copper with skin


4,6  Cell polyethylene with skin and
PIB coating
Polyester foil coated with aluminium
on both sides
FRNC
grey
6,6
45
40

75 1
55
0,8

75 1
55
0,85

75 1
55
0,85

5,8
7,8
12,5
14,7
17,2
19,1
26,2
28,5
31,3

5,8
7,8
12,5
14,7
17,2
19,1
26,2
28,5
31,3

5,8
7,8
12,5
14,7
17,2
19,1
26,2
28,5
31,3

30
32
31
26
30

30
32
31
26
30

30
32
31
26
30

18
20
-

18
20
-

18
20
-

90
22,0

90
22,0

90
22,0

Dimensions and specifications may be changed without prior notice. (RM01)




Application
Copper inner-conductor 1,02 with skin-effect
Protection against humidity and corrosion / Solid compound of dielectric. No change of position duringinstallation in narrow bending
radius.
Dielectric 4,6 mm : - special PE-compound, foaming by GAS-INJEKTION
Important improvement of propagation velocity values / Very high transmission speed of individual signals (presumption for Multimedia)
/ Improvement for the resistance to ageing / Reduction of attenuation-loss
The over surface of dielectric consists too a skin-coating (smooth over surface)
Protection against humidity and other chemical influences / Minimum impedance tolerance 2 Ohm / This coaxial cable is crimpable /
Installation in narrow bending radius, no kinking risk / The transmission-loss of signals are hardly measurable to the advance in years /
Additionally to the skin-effect, the dielectric contains a gel-coating (special PIB-cpmpound) / We therefore offer a 15 years guarantee
for attenuation-loss by installation at 20 C room-temperature
Screening
a) AL/PR-foil, polyesterfoil coated with aluminium on both sides or b) Copper braiding of tinned wires, screening efficiency >90 dB
Outer sheath
Alternatives - PVC white for indoor and outdoor installation / - PE black for underground laying or - FRNC grey as a safety coaxial cable in
hospitals, airports and for medical equipment etc. (other sheath colours on request)

M 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SAT-Coaxial Cables for digital-tv, screening efficieny >90dB / >95dB, for


satellite-receivers, double screened



used as
Type

inner
0,7/2,9

inner/outer
0,7/4,5

inner/outer
0,8/3,5

inner
1,1/5,0

Underground
1.6/7,0

Part no.

Cable structure
Inner conductor diameter mm

40015

40016

40085

40017

40018

0,65
Copper, bare
3
Polyethylene,
foamed
ALPR-FG
foil
Braid
PVC
white
4,3
43
20

0,75
Tinned copper
4,5 
Polyethylene,
foamed
ALPR-FG
foil
Braid
PVC
white
6,6
35
40

0,8
Copper, bare
3,5 
Polyethylene,
foamed
ALPR-FG
foil
Braid
PVC
white
5,0
50
32

1,13
Copper, bare
4,8 
Polyethylene,
foamed
ALPR-FG
foil
Braid
PVC
white
6,9
45
47

75 3
55
0,8

75 3
67
0,66

75 3
53
0,8

8,1
13,3
20,9
31,5
42,2
45,8
49,9
55,5

7,1
10,4
16,8
25
27,4
37,4
40,5
44,3
45

20
18
16
-

Insulation mm
Outer conductor
1stScreen - ALPR
2ndScreen - Cu-Braid
Outer jacket
Jacket colour
Outer approx. mm
Min. bending radiusapprox. mm
Weightapprox. kg/km

Electrical characteristics
Impedance (Ohm)
Capacitance pF/m
Propagation velocity v/c
Attenuationat 20C
(dB/100m)
100 MHz
200 MHz
450 MHz
800 MHz
1000 MHz
1750 MHz
2050 MHz
2250 MHz
2400 MHz
Structural return loss min. (dB) between
30 and 300 MHz
300 and 600 MHz
600 and 960 MHz
960 and 1750 MHz

DC resistanceat 20C
Inner conductormax. Ohm/km
Outer conductormax. Ohm/km
Max. nominal voltage (V)

Screening efficiency (dB)
50 and 100 MHz
100 and 500 MHz
500 and 1000 MHz
1000 and 2050 MHz

Copper weight kg/km

inner
1,1/5,0
FRNC
40019

inner/outer
1,1/5,0
FRNC
40021

inner
1.6/7.0
FRNC
40020

1,63
Copper, bare
7,1 
Polyethylene,
foamed
ALPR-FG
foil
Braid
PE
black
10,3
60
110

1,13
Copper, bare
4,8  Cell PE,
foamed

1,13
Copper, bare
4,8  Cell PE,
foamed

ALPR-FG
foil
Braid
FRNC
white
6,8
48
47

ALPR-FG
foil
Braid
FRNC
black
6,8
48
47

1,63
Copper, bare
7,1 
Polyethylene,
foamed
ALPR-FG
foil
Braid
FRNC
white
10,0
60
110

75 2
55
0,8

75 2
55
0,85

75 2
53
0,85

75 2
55
0,8

75 2
53
0,85

6,3
11,5
17,1
26,5
36,4
39,7
43,1
-

4,9
7,7
11,6
18,9
26,6
28,2
29,5
31,9

3
6,1
9
14,3
20,1
22,5
24
-

4,7
7
11,5
17
18,1
25
27,3
28
29,3

4,9
7,2
11,6
18,9
26,6
28,2
29,5
31,9

3,8
5,5
8,6
12,1
13,2
17,5
19
19,9
22,5

20
18
18
-

35
35
30
30

25
18
17
15

40
35
35
30

25
18
17
15

40
40
35
30

25
18
17
15

52
29
-

110
22
-

36
28
-

18
14
-

9
21
-

18
14
-

18
14
-

9
21
-

95
95
95
95

90
90
90
90

90
90
90
90

95
95
95
95

90
90
90
90

90
90
90
90

95
95
95
95

90
90
90
90

8,0

9,0

9,0

15,0

32,0

15,0

15,0

15,0

Dimensions and specifications may be changed without prior notice. (RM01)

M 11
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

RGB-COAX-CY / RGB-COAX-(St)Y transmission cables for


colour monitor


Technical data

Cable structure

Base cable 0,37/1,5 bzw. 0,6/3,7


Temperature range
fixed installation -10 C to +80 C
flexing -5 C to +50 C
Mutual capacitance 67 nF/km
Impedance 75 Ohm
Attenuation
RGB-Coax 0,37/1,5
1 MHz = 2,0 dB/100m
2 MHz = 2,8 dB/100m
5 MHz = 4,0 dB/100m
10 MHz = 5,8 dB/100m
20 MHz = 8,4 dB/100m
50 MHz = 13,9 dB/100m
100 MHz = 19,8 dB/100m
200 MHz = 28,5 dB/100m
RGB-Coax 0,6/3,7
1 MHz = 1,1 dB/100m
2 MHz = 1,5 dB/100m
5 MHz = 2,5 dB/100m
10 MHz = 3,5 dB/100m
20 MHz = 4,5 dB/100m
50 MHz = 7,2 dB/100m
100 MHz = 10,4 dB/100m
200 MHz = 15,1 dB/100m
Minimum bending radius
15x cable

RGB-COAX-CY ... x0,37/1,5


Inner conductor bare copper, solid,
conductor 0,37 mm
Dielectric (insulation) of cell-Polyethylene
Outer conductor of tinned copper wire
braiding
PVC-jacket in colour
red, green, blue for 3xRGB COAX
red, green, blue, white, black for 5xRGB
COAX
3 or 5 Coax twisted with optimal lay-length
Foil taping
Overall braid-screening, tinned copper with
optimal surface coverage and drain-wire
PVC-outer jacket, black
RGB-COAX-CY 3x0,37/1,5 + 3x0,25
Cable structure as per above, but with
additional control cores (3x0,25) in the
interstices
Colour brown, green, white
RGB-COAX-(St)Y ... x0,6/3,7 (deviation)
Inner conductor, bare copper, solid,
conductor 0,6 mm
Outer conductor of tinned or bare copper
wire braiding
Foil taping
Plastic coated aluminium foil and drain wire
PVC-outer jacket, green or black

Properties
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers.

Application
RGB cables are suitable for the transmission of both analogue and digital video signals.
They are used particularly as connecting cables for data systems, engineering applications (CAD, high-definition graphics) and in television
studios. The three main signals (red, green, blue) are transmitted separately. Depending on the application, it is possible to supply the base
cable with further coaxial cables or with symmetrical signal cores for the intensity and horizontal or vertical synchronisation.


RGB-COAX-CY ... 0,37/1,5


Part no.

No. RGB-Coax
n x mm

40145
40147
40146

3 x 0,37/1,5
3 x 0,37/1,5 + 3 x 0,25
5 x 0,37/1,5

Outer
approx.
mm
7,2
8,2
9,0

Cop.
weight
kg/km
23,0
39,0
36,0

Weight
approx.
kg/km
59,0
89,0
89,0

RGB-COAX-(St)Y ... 0,6/3,7


Part no.

No. RGB-Coax
n x mm

40148
40149

3 x 0,6/3,7
5 x 0,6/3,7

Outer
approx.
mm
16,0
19,0

Cop.
weight
kg/km
66,0
102,0

Weight
approx.
kg/km
278,0
397,0

Dimensions and specifications may be changed without prior notice. (RM01)

M 12
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Cables according to
International Approvals

N1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Cables according to International Approvals


The installation of cables and wires according to
overseas standards is getting more and more
important for the machine and plant industries.
HELUKABEL knows this problem from his
customers and has for a long time delivered
single core and multicore cables according to
the following standards. Due to our extensive
stock capacity, we are in a position to cover your
requirements quickly and correctly.
Please enquire to our sales department.
UL
AWM
MTW
CEI
CSA
SEV
USASI
CNOMO
GOST
CCC
BS

Underwriters Laboratories Inc.


Appliance Wiring Material
Machine Tool Wire
Comitato Elettrotecnico Italiano
Canadian Standard Association
Schweizerischer Elektrotechnischer Verein
USA Standard Institute
Comit De Normalisation Des Moyens
De Production
GOST-R Certication
China Compulsory Certication
British Standard

N2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description
UL/CSA Control Cables
JZ-602,two approvals control cable, 90C, 600V, oil resistant, meter marking.......................................................................................
JZ-603,Multi approvals control cable, oil resistant, meter marking...............................................................................................
JZ-600 UL/CSA,flexible, number coded, 0,6/1kV, meter marking.............................................................................................................
H05VV-F/SJT,300V, according to DINVDE0281 and UL62.......................................................................................................
H05VV-F/SJT,300V, according to DINVDE0281 and UL62.......................................................................................................
H05VV-F/UL,500 V, according to DIN VDE 0281 and UL-Style20195......................................................................................................
FROR CEI 20-22 II............................................................................................................................................................................
C.N.O.M.O,Type N05VV5-F according to NFC 32-207..................................................................................................................................
JZ-602-CY,EMC-preferred type, 90C 600V, screened two approvals control cable, oil resistant, meter marking...........................................
JZ-603-CY,Multi approvals control cable, Cu-screened, EMC-preferred, oil resistant, meter marking.....................................................
JZ-600-Y-CY UL/CSA,flexible, number coded, 0,6/1kV, EMC-preferred type, meter marking.........................................................................
JZ 604 TC TRAY CABLE, PVC power cable, exposed run, 90C, 600V, meter marking..............................................................................
TRAYCONTROL 500,flexible, oil-resistant, open installation TC-ER, PLTC-ER, ITC-ER, NFPA 79 Edition 2007..........................................................
TRAYCONTROL 530,flexible TC-ER control cable with coloured cores.......................................................................................................
TRAYCONTROL 600,flexible, oil-resistant, open installation (TC-ER), NFPA 79 Edition 2007.............................................................................
TRAYCONTROL 670 HDP / 670-C HDP,flexible, oil-resistant, open installation (TC-ER), NFPA 79 Edition 2007................................................
JZ 604-FCY TC TRAY CABLE,PVC power cable, exposed run, screened, NFPA 79 Edition 2007, 90C, 600V, EMC-preferred type, meter marking.........
JZ 604-YCY TC TRAY CABLE,PVC power cable, exposed run, screened, NFPA 79 Edition 2007, 90C, 600V, EMC-preferred type, meter marking.....
TRAYCONTROL 500-C,flexible, oil-resistant, screened, EMC-preferred type, open installation TC-ER, PLTC-ER, ITC-ER, NFPA 79 Edition 2007...............
TRAYCONTROL 600-C,flexible, oil-resistant, screened, EMC-preferred type, open installation (TC-ER), NFPA 79 Edition 2007...................................
TRAYCONTROL 300,flexible, oil-resistant, NFPA 79 Edition 2007.............................................................................................................
TRAYCONTROL 300-C,flexible, oil-resistant, screened, EMC-preferred type, NFPA 79 Edition 2007..................................................................
TRAYCONTROL 300 TP,stranded pair, flexible, oil-resistant, NFPA 79 Edition 2007.....................................................................................
TRAYCONTROL 300-C TP,stranded pair, flexible, screened, oil-resistant, EMC-preferred type, NFPA 79 Edition 2007...........................................
JZ-602-PUR,80C, 600V, two approvals control cable, meter marking...................................................................................................
JZ-602-PUR DC/AC,80C, 600V, two approvals control cable, meter marking........................................................................................
JZ-600 PUR,tear and coolant resistant, 0,6/1kV, meter marking..............................................................................................................
JZ-602-C-PUR,screened two approvals control cable, 80C, 600V, EMC-preferred type, meter marking.........................................................
JZ-600-YC-PUR,tear and coolant resistant, 0,6/1kV, Cu-screened, EMC-preferred type, meter marking.............................................................
MEGAFLEX 500,halogen-free, flame retardant, oil-resistant, UV-resistant, flexible, meter marking.............................................................
MEGAFLEX 500-C,halogen-free, flame retardant, oil-resistant, UV-resistant, flexible, screened, EMC-preferred types, meter marking.................
MEGAFLEX 600,halogen-free, flame retardant, oil-reistant, UV-resistant, flexible, meter marking...................................................................
MEGAFLEX 600-C,halogen-free, flame retardant, oil-resistant, UV-resistant, flexible, meter marking...............................................................
MULTIFLEX 600,highly flexible, oil-resistant, open installation TC-ER, PLTC-ER, NFPA 79 Edition 2007............................................................
MULTIFLEX 600-C,highly-flexible, oil-resistant, screened, EMC-preferred type, control cable for open installation TC-ER, PLTC-ER,
NFPA 79 Edition 2007...................................................................................................................................................................
UL/CSA Data Cables
Command Cable UL (LiYY),Style2464/300V,(80C).........................................................................................................................
Command Cable UL (LiYY),600V, Style2516/600V,(105C)................................................................................................................
Command Cable UL (LiYY-TP),Style2464/300V, 80C......................................................................................................................
Command Cable UL (LiYCY),Style 2464, 300V, 80C, EMC-preferred type...............................................................................................
Command Cable UL (LiYCY),Style2516/600V,105C, EMC-preferred type............................................................................................
Command Cable UL (LiYCY-TP),Style 2464/300 V, 80C, EMC-preferred type.........................................................................................

UL/CSA Heat resistant Cables


SiHF UL/CSA,halogen-free, 150C/ 600 V, two-approvals silicon multicore cable..........................................................................................
SiHF-C-Si UL/CSA,halogen-free, 150C/ 600 V, two-approvals silicon multicore cable, Cu-screened, EMC-preferred type........................................

Page
N 7
N 9

N 10
N 12
N 13
N 14
N 15
N 16
N 17
N 19
N 20
N 25
N 27
N 29
N 30
N 32
N 33
N 34
N 35
N 37
N 38
N 40
N 42
N 44
N 46
N 48
N 49
N 51
N 52
N 54
N 56
N 58
N 60
N 62
N 63
N 65
N 66
N 67
N 69
N 71
N 72
N 75
N 77

N3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description

Page

UL/CSA Rubber Cables


Rubber / Neoprene Control Cable,TypenSJOundSO..................................................................................................................
H07RN-F/SOOW,rubber-sheathed cable, harmonizised type............................................................................................................
UL/CSA Cables for Drag Chains
MULTISPEED 500-PVC UL/CSA,high flexible, safety against high bending in drag chain systems, oil-resistant, low torsion, meter marking........
JZ-602 RC*,cable for drag chains, 90C, 600V, two approvals control cable, meter marking...................................................................
MULTISPEED 500-C-PVC UL/CSA,oil resistant, high flexible, safety against high bending in drag chain systems, low torsion, screened,
EMC-preferred type, meter marking.................................................................................................................................................
JZ-602 RC*-CY,special cable for drag chains, 90C, 600V, two approvals control cable, EMC-preferred type, meter marking..........................
JZ-602 RC*-PUR,special cable for drag chains, 80C, 600V, two approvals control cable, meter marking........................................................
MULTIFLEX 512 -PUR UL/CSA,special cable for drag chains, 80C, 600V, two approvals control cable, halogen-free.....................................
MULTISPEED 500-PUR UL/CSA,safety against high bending in drag chain systems, low torsion, halogen-free, meter marking......................
JZ-602 RC*-C-PUR,special cable for drag chains, 80C, 600V, two approvals control cable, EMC-preferred type, meter marking..........................
MULTIFLEX 512 -C-PUR UL/CSA,special cable for drag chains, 80C, 600V, two approvals control cable, EMC-preferred type, halogen-free,
meter marking..........................................................................................................................................................................
MULTISPEED 500-C-PUR UL/CSA,safety against high bending in drag chain systems, low torsion, halogen-free, EMC-preferred type,
meter marking .........................................................................................................................................................................
MULTISPEED 500-TPE UL/CSA,high flexible, safety against high bending in drag chain systems, low torsion, halogen-free, meter marking...
MULTISPEED 500-C-TPE UL/CSA,safety against high bending in drag chain systems, low torsion, halogen-free, EMC-preferred type,
meter marking......................................................................................................................................................................
SUPERTRONIC-310-PVC,special cable for drag chains, meter marking..............................................................................................
SUPERTRONIC-310-C-PVC,special cable for drag chains, EMC-preferred type, meter marking................................................................
SUPERTRONIC-330 PUR,cable for drag chains, halogen-free, meter marking....................................................................................
SUPERTRONIC-330 C-PUR,cable for drag chains, halogen-free, EMC-preferred type, meter marking......................................................
SUPER-PAAR-TRONIC 340-C-PUR,cable for drag chains, halogen-free, EMC-preferred type, meter marking............................................
MULTISPEED -TRONIC-PUR,safety against high bending in drag chain systems, halogen-free, meter marking............................................
MULTISPEED -TRONIC-C-PUR,safety against high bending in drag chain systems, high flexible, halogen-free, screened, EMC-preferred type,
meter marking...........................................................................................................................................................................

N 79
N 80
N 82
N 83

UL/CSA Single Conductors


UL-Style 1007, CSA TR 64,PVC single cores, 80C, 300V.....................................................................................................................
UL-Style 1569, CSA TR 64,PVC single cores, 105C, 300V...................................................................................................................
UL-Style 1015,PVC single core, 600V..........................................................................................................................................
THREENORM,PVC single core, UL-Style 1013 and CSA 600V................................................................................................................
FIVENORM,HAR-UL-CSA-AWM-MTW, PVC single core, UL-Style 10269/UL-Standard 1063, 600V, 105C........................................................
THHN/THWN,90C, 600V, UL listed, PVC + nylon single core........................................................................................................................
PVC single cores,According to CEI-20-22 II...........................................................................................................................................
HELUTHERM 145,300V, flexible single core, cross-linked, halogen-free...................................................................................................
HELUTHERM 145,600V, flexible single core, cross-linked, halogen-free...................................................................................................
UL-Style 3135,silicone single cores cable, 600V / 200C, halogen-free............................................................................................................
Single 600-J/-O,special single core cable, 0,6/1kV, meter marking.....................................................................................................
Single 600-CY -J/-O,special single core cable, Cu-screened, EMC-preferred type, meter marking..............................................................
Single 602-RC* -J/O,special single core cable for drag chains, 90C, 600V, meter marking..................................................................
Single 602-RC* -CY -J/O,special single core cable for drag chains, 90C, 600V, EMC-preferred type, meter marking............................
MULTISPEED 600-PUR -J/-O,special single cores for drag chains, halogen-free, meter marking............................................................
MULTISPEED 600-C-PUR -J/-O,special cable for drag chains, screened, halogen-free, EMC-preferred type, meter marking..........................

N 84

N 85
N 86
N 87
N 89
N 91
N 92
N 94
N 96
N 98
N 100
N 101
N 102
N 103
N 104
N 105
N 106
N 108
N 109
N 110
N 111
N 113
N 115
N 116
N 117
N 118
N 119
N 120
N 121
N 122
N 123
N 124
N 125

N4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description
UL/CSA Servo, Feedback & Motor Cables
TOPSERV 108 PVC,Motor cable without pair according to Siemens Standard 6FX5008 with PVC-outer sheath for fixed or not constantly
movements 0,6/1kV................................................................................................................................................................
TOPSERV 112 PVC,Servo cable with 1 signal pair according to Siemens Standard 6FX5008 and Lenze Standard with PVC-sheath for fixed or not
constantly movements 0,6/1kV.................................................................................................................................................
TOPSERV 119 PVC,Servo cable with 2 signal pairs analogue Indramat Standard with PVC-sheath for fixed or not constantly movements 0,6/1kV....
TOPGEBER 511 PVC,Feedback cables according to Siemens-, Lenze- or Indramat Standard with PVC-sheath for fixed or not constantly movements.
TOPSERV 109 PUR,PUR, high flexible motor cable for drag chain without pairs according to Siemens Standard 6FX8008-plus 0,6/1kV.......
TOPSERV 113 PUR,PUR, high flexible servo cable for drag chain with 1 signal pair according to Siemens Standard 6FX8008-plus and
Lenze 0,6/1kV...................................................................................................................................................................
TOPSERV 121 PUR,PUR, high flexible servo cable for drag chain with 2 Signal pairs according to Indramat-Standard INK.......................
TOPGEBER 512 PUR,PUR, high flexible Feedback cable for drag chain according to Siemens, Indramat, Lenze and other Standards.........
TOPFLEX 600 VFD,EMC-preferred type, flexible motor power supply cable, oil-resistant, NFPA 79 Edition 2007.................................................
TOPFLEX 650 VFD,EMC-preferred type, flexible motor power supply cable with control cores, oil-resistant, NFPA 79 Edition 2007..........................
TOPSERV 600 VFD,EMC-preferred type, flexible motor power supply cable, oil-resistant, NFPA 79 Edition 2007.......................................
TOPSERV 650 VFD,EMC-preferred type, flexible motor power supply cable with control cores, oil-resistant, NFPA 79 Edition 2007....................
TOPFLEX -EMV-UV-2YSLCYK-J UL/CSA,Motor supply cable 0,6/1kV, for power supply connections to frequency converters, double screened,
meter marking.................................................................................................................................................................................
TOPFLEX -EMV-UV 2YSLCYK-J UL/CSA,Motor supply cable 0,6/1kV, for power supply connections to frequency converters, double screened,
meter marking.................................................................................................................................................................................
TOPFLEX -EMV-UV 2YSLC11Y-J UL/CSA,Motor supply cable 0,6/1kV, for power supply connections to frequency converters, double screened,
meter marking.................................................................................................................................................................................
TOPFLEX MOTOR EMV 1/1,triple-screened, low capacitance, 80C 600V high flexible motor supply cable, meter markingrt...........................
TOPFLEX -MOTOR-EMV 3/3,triple-screened, low capacitance, 80C, 600V, PUR flexible motor supply cable, meter marking...........................
TOPFLEX -MOTOR-EMV 103,low capacitance power supply cable 0,6/1kV, increased ampacity, meter marking...........................................
VERTEILERFLEX two-approvals,sensor actuator and distributor cables PVC, PUR, PVC/PUR.......................................................................

Cables to British Standard


HELUKABEL BS 5308 Part 1,Instruments cable, core insulation PE or XLPE.................................................................................................
HELUKABEL BS 5308 Part 2,Instruments cable, core insulation PVC..........................................................................................................
HELUKABEL BS 5467,High voltage cable 0,6/1kV, armoured, sheath PVC......................................................................................................
HELUKABEL BS 6724,High voltage cable 0,6/1kV, armoured, halogen-free....................................................................................................

Page
N 127
N 128
N 129
N 130
N 131
N 132
N 134
N 135
N 137
N 138
N 139
N 140
N 141
N 143
N 145
N 147
N 148
N 150
N 151
N 154
N 155
N 156
N 157

N5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-602
JZ-603
JZ-600 UL/CSA
H05VV-F/SJT
H05VV-F/UL
FROR CEI 20-22 II
C.N.O.M.O
JZ-602-CY

JZ-603-CY
JZ-600-Y-CY UL/CSA
JZ 604 TC TRAY CABLE
TRAYCONTROL 500
TRAYCONTROL 530
TRAYCONTROL 600
TRAYCONTROL 670
JZ 604-FCY TC TRAY CABLE
JZ 604-YCY TC TRAY CABLE
TRAYCONTROL 500-C
TRAYCONTROL 600-C
TRAYCONTROL 300
TRAYCONTROL 300-C
TRAYCONTROL 300 TP
TRAYCONTROL 300-C TP
JZ-602-PUR
JZ-602-PUR DC/AC
JZ-600 PUR
JZ-602-C-PUR
JZ-600-YC-PUR
MEGAFLEX 500
MEGAFLEX 500-C
MEGAFLEX 600
MEGAFLEX 600-C
MULTIFLEX 600
MULTIFLEX 600-C
Photo: HELUKABEL

UL/CSA Control Cables

N6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-602 two approvals control cable, 90C, 600V, oil resistant,


meter marking


Technical data

Cable structure

Properties

Control cable of special-PVC to UL CSA


AWM I/II A/B Style2587 (jacket insulation)
and CSA
Temperature range
flexing -5 C to +90 C
fixed installation -40 C to +90 C
Nominal voltage
according to UL + CSA 600 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Insulation resistance
min 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire stranded to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special PVC core insulation TI3, to
DINVDE0281 part1 and class43 to
UL-Std.1581
Black conductors with consecutive
numbering in white
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC outer sheath YM5, to
DINVDE0207 part5 and class43 to
UL-Std.1581
Colour grey (RAL 7001)
with meter marking, change-over in 2011

Resistant to mineral oils, synthetic oils and


water based coolants
The outer sheath is approved with an
improved oil-resistance-test
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
Please note the cleanroom qualification
when ordering.
screened analogue type:
JZ-602-CY, see page N 17

Application
UL-approved and CSA certified flexible control cable rated at 600 V. Used in machine tools, control systems, connection between control
panels and machines, assembly lines and other industrial equipment. Suitable for installation in dry, moist or wet environment and moderate
flexing applications.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
83090
83091
83092
83093
83094
83100
83101
83095
83096
83097
83098
83099
83080
83081
83565
83082
83083
83084
83102
83103
83085
83086
83087
83088
83089
83070
83071
83072
83073
83074

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
8G0,5
9G0,5
12G0,5
18G0,5
25G0,5
34G0,5
41G0,5
2x1
3G1
3x1
4G1
5G1
7G1
8G1
9G1
12G1
18G1
25G1
34G1
41G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5

AWG-No. Outer
approx.
mm
20
5,8
20
6,2
20
6,6
20
7,2
20
7,8
20
8,4
20
10,3
20
10,8
20
12,8
20
15,4
20
17,6
20
19,7
18
6,2
18
6,6
18
6,6
18
7,2
18
7,8
18
8,4
18
9,4
18
11,0
18
11,7
18
14,0
18
17,0
18
19,2
18
21,0
16
6,8
16
7,4
16
8,0
16
8,6
16
9,7

Cop.
weight
kg/km
9,6
14,0
19,0
24,0
34,0
38,4
43,2
58,0
86,0
120,0
163,0
197,0
19,2
27,0
27,0
38,4
48,0
67,0
76,8
86,4
115,2
173,0
240,0
326,0
394,0
28,8
44,0
58,0
72,0
101,0

Weight
approx.
kg/km
49,0
58,0
69,0
84,0
123,0
140,0
177,0
192,0
256,0
358,0
487,0
580,0
53,0
61,0
61,0
74,0
90,0
130,0
144,0
180,0
198,0
274,0
384,0
494,0
508,0
73,0
94,0
117,0
140,0
186,0


Part no.
83104
83075
83076
83077
83078
83079
83060
83061
83062
83063
83064
83065
83066
83067
83068
83069
83051
83052
83053
83054
83041
83042
83043
83044
83031
83032
83033
83034

No.cores x
cross-sec.
mm
9G1,5
12G1,5
18G1,5
25G1,5
34G1,5
41G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
9G2,5
12G2,5
18G2,5
19G2,5
25G2,5
3G4
4G4
5G4
7G4
3G6
4G6
5G6
7G6
3G10
4G10
5G10
7G10

AWG-No. Outer
approx.
mm
16
12,7
16
13,3
16
15,7
16
18,8
16
22,0
16
23,6
14
8,1
14
8,6
14
10,0
14
10,8
14
12,0
14
15,5
14
16,6
14
19,5
14
19,5
14
23,8
12
11,1
12
12,4
12
13,7
12
15,0
10
12,8
10
14,1
10
15,7
10
17,7
8
16,8
8
18,3
8
20,1
8
22,4

Cop.
weight
kg/km
129,7
173,0
260,0
360,0
490,0
590,0
48,0
72,0
96,0
120,0
168,0
216,0
288,0
432,0
456,0
600,0
115,0
154,0
192,0
269,0
173,0
231,0
288,0
403,0
288,0
384,0
480,0
672,0

Weight
approx.
kg/km
244,0
319,0
451,0
625,0
840,0
1032,0
115,0
143,0
185,0
221,0
293,0
429,0
563,0
854,0
914,0
1188,0
232,0
298,0
358,0
460,0
360,0
402,0
484,0
630,0
535,0
653,0
786,0
1100,0

Continuation

N7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-602 two approvals control cable, 90C, 600V, oil resistant,


meter marking

Part no.
83020
83021
83022
83023
83024
83011
83012
83013
83014
83001
83002
83003
83004
83005
83006

No.cores x
cross-sec.
mm
2x16
3G16
4G16
5G16
7G16
3G25
4G25
5G25
7G25
3G35
4G35
5G35
3G50
4G50
5G50

AWG-No. Outer
approx.
mm
6
20,0
6
21,3
6
23,8
6
26,6
6
29,4
4
24,7
4
27,8
4
30,5
4
35,5
2
29,4
2
32,6
2
36,3
1
31,2
1
36,8
1
38,7

Cop.
weight
kg/km
307,0
461,0
615,0
768,0
1075,0
720,0
960,0
1200,0
1680,0
1008,0
1344,0
1680,0
1440,0
1920,0
2400,0

Weight
approx.
kg/km
640,0
810,0
1045,0
1260,0
1760,0
1180,0
1507,0
1858,0
2830,0
1590,0
2123,0
2612,0
2652,0
3058,0
4093,0


Part no.
83007
83008
83009
83010
83015
83016
83017
83018
83019

No.cores x
cross-sec.
mm
3G70
4G70
5G70
3G95
4G95
5G95
3G120
4G120
5G120

AWG-No. Outer
approx.
mm
2/0
39,2
2/0
42,6
2/0
48,4
3/0
42,1
3/0
47,5
3/0
51,2
4/0
47,8
4/0
54,6
4/0
59,0

Cop.
weight
kg/km
2016,0
2688,0
3360,0
2736,0
3648,0
4560,0
3456,0
4608,0
5760,0

Weight
approx.
kg/km
3307,0
4254,0
5661,0
4867,0
5762,0
7208,0
5580,0
7280,0
8692,0

Dimensions and specifications may be changed without prior notice. (RN01)

Carrying out a ame test according to the American


standard UL 1581 at our Windsbach factory.

N8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-603 Multi approvals control cable, oil resistant, meter marking




Technical data

Cable structure

Properties

Special PVC control cable with oil resistant


outer sheath to DINVDE0281 part13,
HD21.13S1 and to UL-Style2587
Temperature range
flexing
-5 C to +70 C (HAR)
-5 C to +90 C (UL+CSA)
fixed installation
-40 C to +70 C (HAR)
-40 C to +90 C (UL+CSA)
Nominal voltage
U0/U 300/500 V (HAR)
U 600 V (UL+CSA)
Test voltage 3000 V
Breakdown voltage min. 6000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special PVC core insulation TI1, to
DINVDE0281 part1, HD21.1S2 and class43
to UL-Std.1581
Black cores with white continuous
numbering according to DIN VDE 0293
Green-yellow earth core in the outer layer
Cores stranded in layers with optimal
lay-length
Special PVC outer sheath TM5 oil resistant,
to DINVDE0281 part1, HD21.1S4 and
class43 to UL-Std.1581
Colour grey (RAL 7001)
with meter marking, change-over in 2011

Oil resistant as per HD/EN60811-2-1,


UL1581 part50.182
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB),
UL-VW1.
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
The follwing amendments in the cable
designation result from the new
DINVDE0281 part13 / harmonised in
accordance with HD 21.13S1: NYSLY-J
(new: H05VV5-F) and NYSLYCY-J (new:
H05VVC4V5-K). SEV-approval is no longer
applicable as a result of the harmonisation.
screened analogue type:
JZ-603-CY, see page N 19

Application
UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools,
control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for medium mechanical stresses
with free movements in dry, moist and wet rooms but not for open air.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
83704
83650
83651
83652
83653
83654
83655
83656
83657
83658
83659
83660
83705
83661
83662
83663
83664
83665
83666
83667
83668
83669
83670
83671
83706
83672
83673
83674
83675
83676
83677
83678

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5
34G0,5
41G0,5
50G0,5
61G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75
34G0,75
41G0,75
50G0,75
61G0,75
2x1
3G1
4G1
5G1
7G1
12G1
18G1
25G1

AWG-No. Outer
approx.
mm
20
5,8
20
6,1
20
6,7
20
7,3
20
8,8
20
11,1
20
12,9
20
16,0
20
17,7
20
19,5
20
21,3
20
23,8
19
6,1
19
6,5
19
7,1
19
7,9
19
9,5
19
11,6
19
13,9
19
17,1
19
19,1
19
20,9
19
23,0
19
25,3
18
6,4
18
6,8
18
7,5
18
8,4
18
10,0
18
12,5
18
14,7
18
18,0

Cop.
weight
kg/km
9,6
14,0
19,0
24,0
34,0
58,0
86,0
120,0
163,0
197,0
240,0
293,0
14,4
22,0
29,0
36,0
50,0
86,0
130,0
180,0
245,0
296,0
360,0
439,0
19,2
29,0
39,0
48,0
67,0
115,0
173,0
240,0

Weight
approx.
kg/km
52,0
63,0
69,0
87,0
119,0
198,0
266,0
380,0
508,0
594,0
715,0
840,0
66,0
76,0
85,0
113,0
144,0
245,0
327,0
466,0
626,0
747,0
896,0
1070,0
70,0
88,0
99,0
132,0
170,0
285,0
405,0
570,0


Part no.
83679
83680
83681
83682
83707
83683
83684
83685
83686
83687
83688
83689
83690
83691
83692
83693
83708
83694
83695
83696
83697
83698
83699
83700
83701
83702
83703

No.cores x
cross-sec.
mm
34G1
41G1
50G1
61G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
34G1,5
41G1,5
50G1,5
61G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5
34G2,5
50G2,5
61G2,5

AWG-No. Outer
approx.
mm
18
20,3
18
22,4
18
24,3
18
26,8
16
7,4
16
8,0
16
8,7
16
9,8
16
11,9
16
14,5
16
17,4
16
21,3
16
24,1
16
26,2
16
28,8
16
31,5
14
9,1
14
9,9
14
11,0
14
12,0
14
14,6
14
18,1
14
22,1
14
26,5
14
29,9
14
35,2
14
38,4

Cop.
weight
kg/km
326,0
394,0
480,0
586,0
28,8
43,0
58,0
72,0
101,0
173,0
259,0
360,0
490,0
591,0
720,0
878,0
48,0
72,0
96,0
120,0
168,0
288,0
432,0
600,0
816,0
1200,0
1464,0

Weight
approx.
kg/km
742,0
885,0
1071,0
1265,0
91,0
110,0
141,0
167,0
225,0
361,0
518,0
730,0
945,0
1135,0
1381,0
1640,0
125,0
169,0
209,0
256,0
340,0
579,0
851,0
1175,0
1529,0
2290,0
2724,0

Dimensions and specifications may be changed without prior notice. (RN01)

N9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-600 UL/CSA flexible, number coded, 0,6/1kV, meter marking




Technical data

Cable structure

Properties

Special PVC control cables Adapted to


DINVDE0276 part627, DINVDE0281
part13, with insulation thickness for 1kV
type and UL-Std.758 Style21179
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage 1000 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Power rating
as per DIN VDE 0298
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, as per


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special PVC core insulation TI2, to
DINVDE0281 part1, class43 UL-Std.1581
Black cores with white figure imprints to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Separating foil Special PVC outer sheath
TM2, to DINVDE0281 part1, class43
UL-Std.1581
Colour black (RAL9005) or grey (RAL7001)
with meter marking, change-over in 2011

Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
Resistant to ultra violet rays (building with
black jacket)
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB) VW1,
FT1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
JZ-600-Y-CY UL/CSA, see page N 20

Application
Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air
conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with
free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with
black jacket). Is not suitable to be used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the
numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid
confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly
used in South-European, Eastern and Arabian countries.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
Jacket cross-sec.
colour mm
black
11815
2x0,5
11816
3G0,5
11817
4G0,5
11818
5G0,5
11819
7G0,5
11820
12G0,5
11821
18G0,5
11822
25G0,5
11823
2x0,75
11824
3G0,75
11825
4G0,75
11826
5G0,75
11827
7G0,75
11828
12G0,75
11829
18G0,75
11830
25G0,75
11831
2x1
11832
3G1
11833
4G1
11834
5G1
11835
7G1
11836
12G1
11837
18G1
11838
25G1
11839
2x1,5
11840
3G1,5
11841
4G1,5
11842
5G1,5
11843
7G1,5
11844
12G1,5
11845
18G1,5
11846
25G1,5

AWG-No.

20
20
20
20
20
20
20
20
19
19
19
19
19
19
19
19
18
18
18
18
18
18
18
18
16
16
16
16
16
16
16
16

Outer
Cop.
approx. mm weight
kg/km
6,4
6,8
7,6
8,2
9,8
12,2
14,4
17,2
6,8
7,2
8,0
8,8
10,7
13,1
15,6
18,9
7,4
8,0
8,8
9,8
11,7
14,5
17,3
21,1
8,4
9,1
9,9
11,0
13,3
16,6
19,7
23,9

9,6
14,4
19,0
24,0
33,6
58,0
86,0
120,0
14,4
21,6
29,0
36,0
50,0
86,0
130,0
180,0
19,2
29,2
38,4
48,0
67,0
115,0
173,0
240,0
29,0
43,0
58,0
72,0
101,0
173,0
259,0
360,0

Weight
approx.
kg/km
56,0
68,0
100,0
117,0
138,0
200,0
276,0
335,0
66,0
74,0
126,0
140,0
190,0
257,0
362,0
486,0
80,0
96,0
100,0
130,0
170,0
290,0
405,0
570,0
95,0
112,0
139,0
170,0
225,0
370,0
520,0
730,0


Part no. No.cores x
Jacket cross-sec.
colour mm
grey
11880
2x0,5
11881
3G0,5
11882
4G0,5
11883
5G0,5
11884
7G0,5
11885
12G0,5
11886
18G0,5
11887
25G0,5
11888
2x0,75
11889
3G0,75
11890
4G0,75
11891
5G0,75
11892
7G0,75
11893
12G0,75
11894
18G0,75
11895
25G0,75
11896
2x1
11897
3G1
11898
4G1
11899
5G1
11900
7G1
11901
12G1
11902
18G1
11903
25G1
11904
2x1,5
11905
3G1,5
11906
4G1,5
11907
5G1,5
11908
7G1,5
11909
12G1,5
11910
18G1,5
11911
25G1,5

AWG-No.

20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16

Outer
Cop.
approx. mm weight
kg/km
6,4
6,8
7,6
8,2
9,8
12,2
14,4
17,2
6,8
7,2
8,0
8,8
10,7
13,1
15,6
18,9
7,4
8,0
8,8
9,8
11,7
14,5
17,3
21,1
8,4
9,1
9,9
11,0
13,3
16,6
19,7
23,9

9,6
14,4
19,0
24,0
33,6
58,0
86,0
120,0
14,4
21,6
29,0
36,0
50,0
86,0
130,0
180,0
19,2
29,2
38,4
48,0
67,0
115,0
173,0
240,0
29,0
43,0
58,0
72,0
101,0
173,0
259,0
360,0

Weight
approx.
kg/km
56,0
68,0
100,0
117,0
138,0
200,0
276,0
335,0
66,0
74,0
126,0
140,0
190,0
257,0
362,0
486,0
80,0
96,0
100,0
130,0
170,0
290,0
405,0
570,0
95,0
112,0
139,0
170,0
225,0
370,0
520,0
730,0

Continuation

N 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-600 UL/CSA flexible, number coded, 0,6/1kV, meter marking




Part no. No.cores x


Jacket cross-sec.
colour mm
black
11847
2x2,5
11848
3G2,5
11849
4G2,5
11850
5G2,5
11851
7G2,5
11852
12G2,5
11853
18G2,5
11854
25G2,5
11855
2x4
11856
3G4
11857
4G4
11858
5G4
11859
7G4
11860
12G4
11861
3G6
11862
4G6
11863
5G6
11864
7G6
11865
3G10
11866
4G10
11867
5G10
11868
7G10
11869
3G16
11870
4G16
11871
5G16
11872
7G16
11873
3G25
11874
4G25
11875
5G25
11876
7G25

AWG-No.

14
14
14
14
14
14
14
14
12
12
12
12
12
12
10
10
10
10
8
8
8
8
6
6
6
6
4
4
4
4

Outer
Cop.
approx. mm weight
kg/km
9,4
9,9
11,1
12,4
15,0
18,4
22,0
26,9
11,4
12,3
13,8
15,3
16,8
22,9
14,1
15,6
17,3
19,3
16,5
18,1
20,5
22,5
19,6
21,7
24,2
25,7
24,0
26,9
29,4
32,8

48,0
72,0
96,0
120,0
168,0
288,0
432,0
600,0
77,0
115,0
154,0
192,0
269,0
461,0
173,0
230,0
288,0
403,0
288,0
384,0
480,0
672,0
461,0
614,0
768,0
1075,0
720,0
960,0
1200,0
1680,0

Weight
approx.
kg/km
160,0
175,0
203,0
251,0
330,0
553,0
795,0
1110,0
180,0
230,0
310,0
410,0
540,0
860,0
370,0
430,0
650,0
860,0
660,0
790,0
960,0
1300,0
760,0
1100,0
1600,0
1890,0
1450,0
1600,0
2050,0
2900,0


Part no. No.cores x
Jacket cross-sec.
colour mm
grey
11912
2x2,5
11913
3G2,5
11914
4G2,5
11915
5G2,5
11916
7G2,5
11917
12G2,5
11918
18G2,5
11919
25G2,5
11920
2x4
11921
3G4
11922
4G4
11923
5G4
11924
7G4
11925
12G4
11926
3G6
11927
4G6
11928
5G6
11929
7G6
11930
3G10
11931
4G10
11932
5G10
11933
7G10
11934
3G16
11935
4G16
11936
5G16
11937
7G16
11938
3G25
11939
4G25
11940
5G25
11941
7G25

AWG-No.

14
14
14
14
14
14
14
14
12
12
12
12
12
12
10
10
10
10
8
8
8
8
6
6
6
6
4
4
4
4

Outer
Cop.
approx. mm weight
kg/km
9,4
9,9
11,1
12,4
15,0
18,4
22,0
26,9
11,4
12,3
13,8
15,3
16,8
22,9
14,1
15,6
17,3
19,3
16,5
18,4
20,5
22,5
19,6
21,7
24,2
25,7
24,0
26,9
29,3
32,6

48,0
72,0
96,0
120,0
168,0
288,0
432,0
600,0
77,0
115,0
154,0
192,0
269,0
461,0
173,0
230,0
288,0
403,0
288,0
384,0
480,0
672,0
461,0
614,0
768,0
1075,0
720,0
960,0
1200,0
1680,0

Weight
approx.
kg/km
160,0
175,0
203,0
251,0
330,0
553,0
795,0
1110,0
180,0
230,0
310,0
410,0
540,0
860,0
370,0
430,0
650,0
860,0
660,0
790,0
960,0
1300,0
760,0
1100,0
1600,0
1890,0
1450,0
1600,0
2050,0
2900,0

Dimensions and specifications may be changed without prior notice. (RN01)

N 11
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H05VV-F/SJT 300V, according to DINVDE0281 and UL62




Technical data

Cable structure

Properties

PVC control cable to DINVDE0281 part5


and part2, IEC60227-5, HD21.5S3 and
UL-Std.62 and CSA22.2 No.49
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage
DIN VDE 0281 = U0/U 300/500 V
UL 62 = U 300 V
CSA = U 300 V
Test voltage 2500 V, 5 min.
Breakdown voltage min. 5000 V
Spark-Test 6000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
approx. 7,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire stranded conductor


to DINVDE0295 cl.5, BS6360 cl.5,
IEC60228 cl.5, HD383 and UL-Std.62
PVC insulation TI2 to DINVDE0281 part1
and class43 to UL-Std.62 (Table 50.182,
UL-Std.1581) according to CSA-Std. C22.2
No49 TypeSJT
Core identification according to colour
code DINVDE0293-308, one coloured
Green-yellow earth core, 3 cores and above
Core stranded with optimal lay-length
PVC outer jacket TM2 to DINVDE0281
part1 and class43 to UL-Std.62
(Table50.182, UL-Std.1581) according to
CSA-Std. C22.2 No49 TypeSJT
Jacket colour black, white or grey

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core.

Application
These flexible PVC control cables, VDE-HAR-UL-CSA approved, are designed for the export and also for the export-orientated-equipment.
These cables are especially suited to use for the appliance with medium mechanical stresses with free movement without tensile stress in
households, kitchens and offices, also for household appliances in damp and wet areas, e.g. refrigerators, washing machines, spin-driver
etc., as far as this cable is admitted to the relevant specifications of the equipment.
These cables are suited to be used for cooking and heating apparatus under the condition that cable does not come in direct contact with
hot parts of the apparatus and no other influences or heat.
The cables are suitable for fixed installation in furnitures, partition walls, decoration covering and in hollow spaces of prefabricated building
parts.
They are not suitable for use in open air, in industries (also permitted to tailor workshops and of that kind) and in agriculture plants and for
connecting commercial electrical tools.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
28034
2x1
28066
2x1
28050
2x1
28035
3G1
28067
3G1
28051
3G1
28036
4G1
28068
4G1
28052
4G1
28037
5G1
28069
5G1
28053
5G1
28038
2x1,5
28070
2x1,5
28054
2x1,5
28039
3G1,5
28071
3G1,5
28055
3G1,5
28040
4G1,5
28072
4G1,5
28056
4G1,5
28041
5G1,5
28073
5G1,5
28057
5G1,5

Jacket
colour
black
grey
white
black
grey
white
black
grey
white
black
grey
white
black
grey
white
black
grey
white
black
grey
white
black
grey
white

Outer
approx.
mm

7,3
7,3
7,3
7,8
7,8
7,8
8,6
8,6
8,6
9,4
9,4
9,4
7,9
7,9
7,9
8,4
8,4
8,4
9,3
9,3
9,3
10,4
10,4
10,4

Cop.
Weight AWG-No.
weight approx.
kg/km kg/km
19,2
56,0
17
19,2
56,0
17
19,2
56,0
17
28,8
73,0
17
28,8
73,0
17
28,8
73,0
17
38,4
86,0
17
38,4
86,0
17
38,4
86,0
17
48,0
105,0
17
48,0
105,0
17
48,0
105,0
17
28,8
82,0
16
28,8
82,0
16
28,8
82,0
16
44,0
96,0
16
44,0
96,0
16
44,0
96,0
16
58,0
117,0
16
58,0
117,0
16
58,0
117,0
16
72,0
144,0
16
72,0
144,0
16
72,0
144,0
16


Part no. No.cores x
cross-sec.
mm
28042
2x2,5
28074
2x2,5
28058
2x2,5
28043
3G2,5
28075
3G2,5
28059
3G2,5
28044
4G2,5
28076
4G2,5
28060
4G2,5
28045
5G2,5
28077
5G2,5
28061
5G2,5
28046
2x4
28078
2x4
28062
2x4
28047
3G4
28079
3G4
28063
3G4
28048
4G4
28080
4G4
28064
4G4
28049
5G4
28081
5G4
28065
5G4

Jacket
colour
black
grey
white
black
grey
white
black
grey
white
black
grey
white
black
grey
white
black
grey
white
black
grey
white
black
grey
white

Outer
approx.
mm

9,2
9,2
9,2
10,0
10,0
10,0
10,9
10,9
10,9
12,2
12,2
12,2
10,6
10,6
10,6
11,5
11,5
11,5
12,4
12,4
12,4
14,1
14,1
14,1

Cop.
Weight AWG-No.
weight approx.
kg/km kg/km
48,0
118,0
14
48,0
118,0
14
48,0
118,0
14
72,0
152,0
14
72,0
152,0
14
72,0
152,0
14
96,0
192,0
14
96,0
192,0
14
96,0
192,0
14
120,0
243,0
14
120,0
243,0
14
120,0
243,0
14
76,8
195,0
12
76,8
195,0
12
76,8
195,0
12
115,0
235,0
12
115,0
235,0
12
115,0
235,0
12
154,0
300,0
12
154,0
300,0
12
154,0
300,0
12
192,0
361,0
12
192,0
361,0
12
192,0
361,0
12

Dimensions and specifications may be changed without prior notice. (RN01)

N 12
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H05VV-F/SJT 300V, according to DINVDE0281 and UL62




Technical data

Cable structure

Properties

PVC control cable to DINVDE0281 part5


and part2, IEC60227-5, HD21.5S3 and
UL-Std.62 and CSA22.2 No.49
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage
DIN VDE 0281 = U0/U 300/500 V
UL 62 = U 300 V
CSA = U 300 V
Test voltage 2500 V, 5 min.
Breakdown voltage min. 5000 V
Spark-Test 6000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
approx. 7,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire stranded conductor


to DINVDE0295 cl.5, BS6360 cl.5,
IEC60228 cl.5, HD383 and UL-Std.62
PVC insulation TI2 to DINVDE0281 part1
and class43 to UL-Std.62 (Table 50.182,
UL-Std.1581) according to CSA-Std. C22.2
No49 TypeSJT
Core identification according to colour
code DINVDE0293-308, one coloured
Green-yellow earth core, 3 cores and above
Core stranded with optimal lay-length
PVC outer jacket TM2 to DINVDE0281
part1 and class43 to UL-Std.62
(Table50.182, UL-Std.1581) according to
CSA-Std. C22.2 No49 TypeSJT
Jacket colour by request

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
Colour code:
0 = RAL 5015, blue
1 = RAL 6018, green
2 = RAL 8003, brown
3 = RAL 1021, yellow
4 = RAL 3000, red
5 = RAL 2003, orange
6 = RAL 4005, violet
7 = gold
8 = dusky gold
Please add the individual part no. for order
with the identification colour code.
Further colours on request.

Application
These flexible PVC control cables, VDE-HAR-UL-CSA approved, are designed for the export and also for the export-orientated-equipment.
These cables are especially suited to use for the appliance with medium mechanical stresses with free movement without tensile stress in
households, kitchens and offices, also for household appliances in damp and wet areas, e.g. refrigerators, washing machines, spin-driver
etc., as far as this cable is admitted to the relevant specifications of the equipment.
These cables are suited to be used for cooking and heating apparatus under the condition that cable does not come in direct contact with
hot parts of the apparatus and no other influences or heat.
The cables are suitable for fixed installation in furnitures, partition walls, decoration covering and in hollow spaces of prefabricated building
parts.
They are not suitable for use in open air, in industries (also permitted to tailor workshops and of that kind) and in agriculture plants and for
connecting commercial electrical tools.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
3110_
3111_
3112_
3113_
3114_
3115_
3116_
3117_

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
2x1,5
3G1,5
4G1,5
5G1,5

Outer
Cop.
approx. mm weight
kg/km
7,3
19,2
7,8
28,8
8,6
38,4
9,4
48,0
7,9
28,8
8,4
44,0
9,3
58,0
10,4
72,0

Weight
approx.
kg/km
56,0
73,0
86,0
105,0
82,0
96,0
117,0
144,0

AWG-No.
17
17
17
17
16
16
16
16


Part no.
3118_
3119_
3120_
3121_
3122_
3123_
3124_
3125_

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
2x4
3G4
4G4
5G4

Outer
Cop.
approx. mm weight
kg/km
9,2
48,0
10,0
72,0
10,9
96,0
12,2
120,0
10,6
76,8
11,5
115,0
12,4
154,0
14,1
192,0

Weight
approx.
kg/km
118,0
152,0
192,0
243,0
195,0
235,0
300,0
361,0

AWG-No.
14
14
14
14
12
12
12
12

Dimensions and specifications may be changed without prior notice. (RN01)

N 13
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H05VV-F/UL 500 V, according to DIN VDE 0281 and UL-Style20195




Technical data

Cable structure

Properties

PVC control cable to DINVDE0281 part5


and part2, IEC60227-5, HD21.5S3 and
UL-Subj.758 AWM-Style 20195
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage
DIN VDE 0281 = U0/U 300/500 V
UL-Style 20195 = U0/U 300/500 V
Test voltage 2500 V
Breakdown voltage min. 5000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
approx. 7,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5, IEC60228 cl.5, HD383 and to UL-Std.
62
PVC core insulation TI2 to DINVDE0281
part1
Cores colour coded to DINVDE0293-308
Green-yellow earth core, 3 cores and above
Core stranded in layers with optimal
lay-length
PVC outer jacket, colour by request
PVC outer jacket TM2 to DINVDE0281
part1


PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Colour code:
0 = RAL 9005, black
1 = RAL 9003, white
2 = RAL 5015, blue
3 = RAL 6018, green
4 = RAL 8003, brown
5 = RAL 1021, yellow
6 = RAL 3000, red
7 = RAL 2003, orange
8 = RAL 4005, violet
9 = RAL 7001/7032, grey
Please add the individual part no. for order
with the identification colour code.
Further colours on request.

Application
These flexible PVC control cables, VDE-HAR-AWM approved, are designed for the export and also for the export-orientated-equipment.
These cables are especially suited to use for the appliance with medium mechanical stresses with free movement without tensile stress in
households, kitchens and offices, also for household appliances in damp and wet areas, e.g. refrigerators, washing machines, spin-driver
etc., as far as this cable is admitted to the relevant specifications of the equipment.
These cables are suited to be used for cooking and heating apparatus under the condition that cable does not come in direct contact with
hot parts of the apparatus and no other influences or heat.
The cables are suitable for fixed installation in furnitures, partition walls, decoration covering and in hollow spaces of prefabricated building
parts.
They are not suitable for use in open air, in industries (also permitted to tailor workshops and of that kind) and in agriculture plants and for
connecting commercial electrical tools.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
3269_
3270_
3271_
3272_
3273_
3274_
3275_
3276_
3277_
3278_

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
2x1
3G1
4G1
5G1
2x1,5
3G1,5

Outer
Cop.
approx. mm weight
kg/km
6,4
14,4
6,8
21,6
7,4
29,0
8,3
36,0
7,3
19,0
7,8
29,0
8,6
38,0
9,4
48,0
7,9
29,0
8,4
43,0

Weight
approx.
kg/km
50,0
60,0
73,0
88,0
57,0
73,0
85,0
105,0
82,0
95,0

AWG-No.
18
18
18
18
17
17
17
17
16
16


Part no.
3279_
3280_
3281_
3282_
3283_

No.cores x
cross-sec.
mm
4G1,5
5G1,5
3G2,5
4G2,5
5G2,5

Outer
Cop.
approx. mm weight
kg/km
9,3
58,0
10,4
72,0
10,0
72,0
10,9
96,0
12,2
120,0

Weight
approx.
kg/km
117,0
144,0
152,0
192,0
243,0

AWG-No.
16
16
14
14
14

Dimensions and specifications may be changed without prior notice. (RN01)

N 14
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

FROR CEI 20-22 II




Technical data

Cable structure

Properties

Special PVC-sheath flexible cord as per


Italian standard CEI20-22
Temperature range
flexing -5 C to +70 C
fixed installation -35 C to +70 C
Nominal voltage
to 5 cores U0/U 450/750 V
at 7 cores U0/U 300/500 V 
Test voltage 2000 V
Insulation resistance
min. 20 MOhm x km
Radiation resistance
up to 80x106 cJ/kg (80 Mrad)
Minimum bending radius
approx. 10x cable

Bare copper conductor, fine wire stranded


to CEI20-29 cl.5
Special PVC compound MiR2
Colour coded up and to4 cores to
HELUKABEL-JB colour code see Technical
Informations
As of 5 cores black with continuous white
number printing
Green-yellow earth core
Cores stranded in layers with optimal
lay-length
Special PVC outer sheath
Sheath colour grey, similar to RAL7035,
with printing CEI20-22II

Oil- and petrol resistant as perCEI20-22II


Conditionally resistant to
Oil
Solvents
Acids
Lyes
PVC self-extinguishing and flame retardant,
test methods analog to IEC60332-3
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core.


AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Well known companies (FIAT, COMAU, etc.) use this cable for measurement and control purposes on machine tools and conveyors, as well
as on production lines in equipment production and for special mechanical engineering. These cables are used for flexible use for medium
mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open
air. Due to special conductor insulation- and sheath compound, this cable is flame resistant in case of fire and self-extinguishing. The good
oil- and petrol resistance allows the usage of this cable also in problem areas.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
60250
60251
60252
60253
60254
60255
60256
60284
60285
60257
60258
60259
60260
60261
60262
60263
60264
60265
60266
60267
60286
60268
60269

No.cores x
cross-sec.
mm
3G1
4G1
5G1
7G1
12G1
18G1
25G1
27G1
33G1
34G1
42G1
50G1
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
34G1,5
37G1,5
42G1,5
50G1,5

Outer
Cop.
approx. mm weight
kg/km
8,5
29,0
9,5
39,0
10,5
48,0
10,8
67,0
13,8
115,0
16,5
173,0
19,5
240,0
20,0
259,0
20,8
317,0
21,0
326,0
23,3
405,0
25,0
480,0
9,6
43,0
11,0
58,0
12,0
72,0
12,5
101,0
16,0
173,0
18,8
259,0
23,0
360,0
26,0
490,0
26,5
533,0
29,5
605,0
30,5
720,0

Weight
approx.
kg/km
85,0
100,0
123,0
160,0
270,0
380,0
500,0
560,0
700,0
720,0
800,0
1050,0
105,0
150,0
190,0
220,0
350,0
515,0
705,0
990,0
1005,0
1080,0
1330,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16


Part no.
60287
60270
60271
60272
60273
60274
60275
60276
60277
60278
60279
60280
60281
60282
60283

No.cores x
cross-sec.
mm
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
4G4
7G4
4G6
4G10
4G16
4G25
4G35
4G50
4G70
4G95

Outer
Cop.
approx. mm weight
kg/km
11,3
72,0
12,3
96,0
12,6
120,0
14,5
168,0
18,0
288,0
14,0
154,0
16,0
269,0
16,0
230,0
19,0
384,0
23,0
614,0
28,0
960,0
31,0
1344,0
37,0
1920,0
43,0
2688,0
50,0
3648,0

Weight
approx.
kg/km
190,0
215,0
270,0
350,0
550,0
300,0
500,0
430,0
700,0
1000,0
1550,0
2070,0
2850,0
4000,0
5400,0

AWG-No.
14
14
14
14
14
12
12
10
8
6
4
2
1
2/0
3/0

Dimensions and specifications may be changed without prior notice. (RN01)

N 15
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

C.N.O.M.O Type N05VV5-F according to NFC 32-207




Technical data

Cable structure

Properties

Special PVC based core insulation


As per to the french motor industry
standard for tool machines04-24-22
Temperature range
flexing -5 C to +80 C
fixed installation -30 C to +80 C
Nominal voltage 500 V
Test voltage 2000 V
Insulation resistance
min. 20 MOhm x km
Radiation resistance
up to 80x106 cJ/kg (80 Mrad)
Minimum bending radius
15x cable

Plain copper conductors


Special core insulation
Cores laid up
Cores available in either red or black with
white figure imprint
Green-yellow earth core
PVC outer jacket grey

PVC self-extinguishing and flame retardant,


text methodB and IEC60332-1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Resistant to
Oil
Petrol
Cutting oil according to C.N.O.M.O
recommendationE03.40.150N


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Further types and sizes available on
request.

Application
These cables are constructed specially for the french automobile industries and used for the installation in tool making machines, production
lines, industrial plants, air conditioning as well as for use in steel production. These cables are used for flexible use for medium mechanical
stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
60000
60001
60002
60003
60004
60005
60006
60007
60008
60009
60010
60011
60012
60013
60014
60015
60016
60017
60018
60019
60020
60021
60022
60023
60024
60025
60026
60027
60028
60029
60030
60031
60032
60033

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
6G0,75
12G0,75
18G0,75
27G0,75
36G0,75
48G0,75
60G0,75
2x1
3G1
4G1
5G1
6G1
12G1
18G1
27G1
36G1
48G1
60G1
2x1,5
3G1,5
4G1,5
5G1,5
6G1,5
12G1,5
18G1,5
24G1,5
27G1,5
36G1,5
48G1,5
60G1,5

Outer
Cop.
approx. mm weight
kg/km
6,2
14,4
6,6
21,6
7,2
29,0
8,0
36,0
8,9
50,0
11,6
86,0
13,9
144,0
17,2
230,0
19,7
288,0
22,8
360,0
24,9
439,0
6,5
19,0
6,9
29,0
7,7
38,0
8,5
48,0
9,2
67,0
12,4
115,0
15,2
192,0
18,7
308,0
21,1
384,0
24,3
480,0
26,4
586,0
7,5
29,0
8,1
43,0
9,1
58,0
10,1
72,0
11,0
101,0
15,1
173,0
17,9
263,0
21,0
341,0
21,8
372,0
24,5
498,0
28,4
641,0
31,3
878,0

Weight
approx.
kg/km
50,0
59,0
72,0
87,0
105,0
175,0
267,0
404,0
503,0
670,0
805,0
56,0
72,0
84,0
104,0
124,0
219,0
314,0
485,0
620,0
809,0
1000,0
76,0
94,0
116,0
143,0
173,0
307,0
464,0
629,0
708,0
985,0
1175,0
1415,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16


Part no.
60034
60035
60036
60037
60038
60039
60040
60041
60042
60043
60044
60045
60046
60047
60048
60049
60050
60051

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
6G2,5
12G2,5
2x4
3G4
4G4
5G4
2x6
3G6
4G6
5G6
2x10
3G10
4G10
5G10

Outer
Cop.
approx. mm weight
kg/km
10,5
48,0
11,0
72,0
12,0
96,0
13,1
120,0
15,0
168,0
18,0
288,0
10,4
77,0
11,3
115,0
12,8
154,0
14,2
192,0
11,6
115,0
12,7
173,0
14,2
230,0
15,7
288,0
15,0
194,0
16,6
288,0
18,4
384,0
20,9
480,0

Weight
approx.
kg/km
122,0
151,0
191,0
244,0
292,0
524,0
178,0
230,0
300,0
362,0
218,0
325,0
481,0
584,0
505,0
610,0
736,0
913,0

AWG-No.
14
14
14
14
14
14
12
12
12
12
10
10
10
10
8
8
8
8

Dimensions and specifications may be changed without prior notice. (RN01)

N 16
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-602-CY EMC-preferred type, 90C 600V, screened two approvals


control cable, oil resistant, meter marking


Technical data

Cable structure

Properties

Special PVC-insulated sheathed cable


according to UL AWM Style10012 (core
insulation) Style2587 and CSA
Temperature range
flexing -5 C to +90 C
fixed installation -40 C to +90 C
Nominal voltage according to UL+CSA
600 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, fine wire stranded to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special PVC core insulation TI3, to
DINVDE0281 part1 and class43 to
UL-Std.1581
Cores black with sequential numbering
imprinted in white
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
PVC-insulated inner sheath YM5 to
DINVDE0207 part5
Braided screen of tinned Cu wires approx.
85% coverage
Special PVC outer sheath YM5, to
DINVDE0207 part5 and class43 to
UL-Std.1581
Colour grey (RAL 7001)
with meter marking, change-over in 2011

Resistant to mineral oils, synthetic oils and


refrigerants. The outer sheath is approved
with an improved oil-resistance-test.
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
when ordering.
unscreened analogue type:
JZ-602, see page N 7

Application
UL and CSA approved flexible control cables up to 600 V, for all machinery in tooling and plant construction, suitable for installation in dry,
moist or wet environments for medium mechanical loads. Designed for the export-orientated machinery manufacturer, specifically for USA
and Canada. The thick braiding screen ensures compliance with electromagnetic requirements.
EMC = Electromagnetic compatibility
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
82990
82991
82992
82993
82994
82995
82996
82997
82998
82999
83000
82979
82980
82981
82982
82983
82984
82985
82986
82987
82988
82989
82968
82969
82970
82971
82972
82973
82974
82975
82976

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
9G0,5
12G0,5
18G0,5
25G0,5
34G0,5
41G0,5
2x1
3G1
4G1
5G1
7G1
9G1
12G1
18G1
25G1
34G1
41G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
9G1,5
12G1,5
18G1,5
25G1,5

AWG-No. Outer
approx.
mm
20
7,7
20
8,0
20
8,6
20
9,2
20
10,0
20
11,8
20
13,0
20
15,2
20
18,2
20
20,1
20
22,4
18
8,1
18
8,4
18
9,3
18
10,0
18
10,7
18
12,7
18
14,0
18
16,4
18
19,7
18
22,1
18
24,5
16
8,7
16
9,4
16
10,2
16
11,0
16
12,0
16
14,2
16
15,6
16
18,7
16
22,6

Cop.
weight
kg/km
35,0
42,0
47,0
56,0
69,0
87,0
108,0
145,0
240,0
312,0
348,0
50,0
60,0
71,0
88,0
111,0
139,0
184,0
260,0
349,0
486,0
531,0
63,0
80,0
97,0
119,0
147,0
182,0
267,0
374,0
526,0

Weight
approx.
kg/km
93,0
124,0
133,0
153,0
191,0
243,0
322,0
374,0
436,0
560,0
663,0
107,0
130,0
155,0
181,0
209,0
321,0
341,0
473,0
650,0
781,0
892,0
136,0
165,0
192,0
224,0
273,0
340,0
461,0
674,0
950,0


Part no.
82977
82978
82959
82960
82961
82962
82963
82964
82965
82966
82967
82954
82955
82956
82957
82958
82949
82950
82951
82952
82953
82945
82946
82947
82948
82941
82942

No.cores x
cross-sec.
mm
34G1,5
41G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
9G2,5
12G2,5
18G2,5
25G2,5
2x4
3G4
4G4
5G4
7x4
2G6
3G6
4G6
5G6
7G6
3G10
4G10
5G10
7G10
3G16
4G16

AWG-No. Outer
approx.
mm
16
25,5
16
27,4
14
10,3
14
10,8
14
11,7
14
13,0
14
14,2
14
15,8
14
17,1
14
18,9
14
27,8
12
12,5
12
13,1
12
14,4
12
15,8
12
17,6
10
14,2
10
15,1
10
16,5
10
18,3
10
20,9
8
19,1
8
21,1
8
23,6
8
26,4
6
24,3
6
27,5

Cop.
weight
kg/km
629,0
801,0
96,0
144,0
148,0
181,0
255,0
309,0
441,0
570,0
738,0
120,0
174,0
230,0
273,0
316,0
173,0
240,0
305,0
439,0
505,0
350,0
535,0
592,0
810,0
585,0
740,0

Weight
approx.
kg/km
1203,0
1588,0
173,0
220,0
270,0
329,0
428,0
580,0
761,0
1140,0
1551,0
209,0
310,0
456,0
532,0
737,0
318,0
411,0
572,0
732,0
961,0
741,0
988,0
1202,0
1743,0
1088,0
1662,0

Continuation

N 17
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-602-CY EMC-preferred type, 90C 600V, screened two approvals


control cable, oil resistant, meter marking

Part no.
82943
82944
82937
82938
82939
82940
82934
82935
82936
82488
82780
82781
82782
82783
82914
82915
82916
82917

No.cores x
cross-sec.
mm
5G16
7G16
3G25
4G25
5G25
7G25
3G35
4G35
5G35
3G50
4G50
5G50
3G70
4G70
5G70
3G95
4G95
5G95

AWG-No. Outer
approx.
mm
6
31,2
6
34,1
4
29,9
4
32,9
4
36,4
4
39,0
2
32,8
2
36,3
2
39,9
1
35,0
1
41,0
1
44,4
2/0
41,4
2/0
46,7
2/0
50,6
3/0
46,2
3/0
51,2
3/0
56,1

Cop.
weight
kg/km
895,0
1282,0
1070,0
1140,0
1380,0
1870,0
1240,0
1576,0
1930,0
1675,0
2155,0
2794,0
2288,0
3120,0
3705,0
3010,0
4043,0
5026,0

Weight
approx.
kg/km
2021,0
2720,0
1947,0
2591,0
3197,0
4530,0
2701,0
3277,0
4530,0
2870,0
3960,0
4371,0
3647,0
4882,0
5876,0
4751,0
6368,0
7843,0


Part no.
82918
82919
82920

No.cores x
cross-sec.
mm
3G120
4G120
5G120

AWG-No. Outer
approx.
mm
4/0
52,0
4/0
58,7
4/0
62,7

Cop.
weight
kg/km
3812,0
5069,0
5877,0

Weight
approx.
kg/km
5899,0
8010,0
9205,0

Dimensions and specifications may be changed without prior notice. (RN01)

Insulating, shrinking, braided and


temperature protection tubes
Braided hoses
High temperature protection
Insulation tubes
Heat-shrink tubes
End caps

You can nd insulating, shrinking, braided and temperature protection tubes


in our catalogue Cable Accessories.

N 18
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-603-CY Multi approvals control cable, Cu-screened,


EMC-preferred, oil resistant, meter marking


Technical data

Cable structure

Properties

Special PVC control cable with oil resistant


outer sheath to DINVDE0281 part13,
HD21.13S1 and to UL-Style2587
Temperature range
flexing -5 C to +70 C (HAR)
-5 C to +90 C (UL+CSA)
fixed installation -40 C to +70 C (HAR)
-40 C to +90 C (UL+CSA)
Nominal voltage
U0/U 300/500 V (HAR)
U 600 V (UL+CSA)
Test voltage 3000 V
Breakdown voltage min. 6000 V
Insulation resistance
min. 20MOhm x km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, fine wire conductor to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special PVC core insulation TI1, to
DINVDE0281 part1, HD21.1S2 and class43
to UL-Std.1581
Black cores with white continuous
numbering according to DIN VDE 0293
Green-yellow earth core in the outer layer
Cores stranded in layers with optimal
lay-length
PVC based inner sheath
Tinned copper braiding screening, 85%
coverage
Special PVC outer sheath TM5, oil resistant
to DINVDE0281 part1, HD21.1S4 and
class43 to UL-Std.1581
Colour grey (RAL 7001)
with meter marking, change-over in 2011

Oil resistant as per DIN EN60811-2-1,


UL1581 part50.182
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB) UL
VW-1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
The follwing amendments in the cable
designation result from the new
DINVDE0281 part13 / harmonised in
accordance with HD 21.13S1: NYSLY-J
(new: H05VV5-F) and NYSLYCY-J (new:
H05VVC4V5-K). SEV-approval is no longer
applicable as a result of the harmonisation.
unscreened analogue type:
JZ-603, see page N 9

Application
UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools,
control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for medium mechanical stresses
with free movements in dry, moist and wet rooms but not for open air.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
83709
83720
83721
83722
83723
83724
83725
83726
83727
83728
83729
83730
83710
83731
83732
83733
83734
83735
83736
83737
83738
83739
83740
83741
83711
83742
83743
83744
83745
83746

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5
34G0,5
41G0,5
50G0,5
61G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75
34G0,75
41G0,75
50G0,75
61G0,75
2x1
3G1
4G1
5G1
7G1
12G1

AWG-No. Outer
approx.
mm
20
8,0
20
8,3
20
8,9
20
9,7
20
11,2
20
13,6
20
15,4
20
18,6
20
20,8
20
22,6
20
24,8
20
26,0
19
8,3
19
8,6
19
9,4
19
10,1
19
11,9
19
14,2
19
16,6
19
20,0
19
22,4
19
24,0
19
26,2
19
30,0
18
8,6
18
9,2
18
9,8
18
10,7
18
12,5
18
15,1

Cop.
weight
kg/km
41,0
45,0
54,0
66,0
79,0
137,0
156,0
250,0
316,0
348,0
407,0
520,0
46,0
57,0
63,0
76,0
100,0
175,0
240,0
306,0
346,0
403,0
470,0
550,0
54,0
64,0
76,0
89,0
114,0
186,0

Weight
approx.
kg/km
90,0
105,0
123,0
147,0
195,0
276,0
418,0
504,0
632,0
750,0
968,0
1068,0
101,0
127,0
155,0
180,0
225,0
326,0
457,0
635,0
805,0
908,0
1155,0
1400,0
113,0
144,0
178,0
205,0
263,0
424,0


Part no.
83747
83748
83749
83750
83751
83752
83712
83753
83754
83755
83756
83757
83758
83759
83760
83761
83762
83763
83713
83764
83765
83766
83767
83768
83769
83770
83771
83772
83773

No.cores x
cross-sec.
mm
18G1
25G1
34G1
41G1
50G1
61G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
34G1,5
41G1,5
50G1,5
61G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5
34G2,5
50G2,5
61G2,5

AWG-No. Outer
approx.
mm
18
17,3
18
21,1
18
23,5
18
25,5
18
27,6
18
32,4
16
9,6
16
10,1
16
11,0
16
12,3
16
14,2
16
17,1
16
20,0
16
24,0
16
27,1
16
29,7
16
31,8
16
34,6
14
11,4
14
12,0
14
13,4
14
14,6
14
17,2
14
21,2
14
24,8
14
29,8
14
33,4
14
39,0
14
41,0

Cop.
weight
kg/km
284,0
387,0
500,0
578,0
681,0
710,0
64,0
82,0
99,0
123,0
148,0
274,0
386,0
531,0
671,0
840,0
997,0
1120,0
110,0
148,0
169,0
220,0
284,0
470,0
572,0
740,0
1179,0
1660,0
1992,0

Weight
approx.
kg/km
560,0
760,0
945,0
1151,0
1300,0
1500,0
144,0
160,0
210,0
240,0
305,0
482,0
611,0
950,0
1200,0
1400,0
1665,0
1852,0
189,0
244,0
296,0
367,0
478,0
622,0
1010,0
1375,0
1893,0
2666,0
3077,0

Dimensions and specifications may be changed without prior notice. (RN01)

N 19
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-600-Y-CY UL/CSA flexible, number coded, 0,6/1kV, EMC-preferred


type, meter marking


Technical data

Cable structure

Properties

Special PVC control cables


Adapted to DINVDE0276 part627,
DINVDE0281 part13, with insulation
thickness for 1 kV type and UL-Std.758
Style21179
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +90 C
Nominal voltage U 1000 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Power rating
according to DIN VDE 0298
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, fine wire conductors,


according to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Special PVC core insulation TI2, to
DINVDE0281 part1, class43 UL-Std.1581
Black cores with sequential numbering
imprinted in white, according to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
PVC-insulated inner sheath TM2, to
DINVDE0281 part1, class43 UL-Std.1581
Braided screen of tinned Cu wires,
coverage approx. 85%
Special PVC outer sheath TM2, to
DINVDE0281 part1 class43 UL-Std.1581
Colour black (RAL9005) or grey (RAL7001)
with meter marking, change-over in 2011

Extensively oil resistant, oil-/ chemical


Resistance - see table Technical
Informations
UV-resistant(building with black jacket)
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
VW-1, FT1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
JZ-600 UL/CSA, see page N 10

Application
Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air
conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with
free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with
black jacket). Is not suitable to be used as direct burrial- or as underwater cable. Interference-free transmission of signals and pulses is assured
by the high degree of screening.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
Jacket cross-sec.
colour mm
black
12345
2x0,5
12346
3G0,5
12347
4G0,5
12348
5G0,5
12349
7G0,5
12350
12G0,5
12351
18G0,5
12352
25G0,5
12353
2x0,75
12354
3G0,75
12355
4G0,75
12356
5G0,75
12357
7G0,75
12358
12G0,75
12359
18G0,75
12360
25G0,75
12361
2x1
12362
3G1
12363
4G1
12364
5G1
12365
7G1
12366
12G1
12367
18G1
12368
25G1
12369
2x1,5
12370
3G1,5
12371
4G1,5

AWG-No.

20
20
20
20
20
20
20
20
19
19
19
19
19
19
19
19
18
18
18
18
18
18
18
18
16
16
16

Outer
Cop.
approx. mm weight
kg/km
8,3
8,6
9,4
10,1
12,1
14,7
17,3
20,6
8,7
9,0
9,9
10,8
13,0
15,8
17,9
22,8
9,4
9,8
10,8
12,1
14,5
17,4
20,7
24,8
10,2
10,9
12,2

41,0
45,0
54,0
66,0
79,0
137,0
156,0
250,0
46,0
57,0
63,0
76,0
100,0
175,0
240,0
306,0
54,0
64,0
76,0
89,0
114,0
186,0
284,0
387,0
64,0
82,0
99,0

Weight
approx.
kg/km
129,0
150,0
170,0
199,0
235,0
320,0
428,0
503,0
143,0
155,0
190,0
228,0
323,0
410,0
560,0
730,0
150,0
163,0
200,0
239,0
289,0
464,0
628,0
855,0
162,0
187,0
240,0


Part no. No.cores x
Jacket cross-sec.
colour mm
grey
12410
2x0,5
12411
3G0,5
12412
4G0,5
12413
5G0,5
12414
7G0,5
12415
12G0,5
12416
18G0,5
12417
25G0,5
12418
2x0,75
12419
3G0,75
12420
4G0,75
12421
5G0,75
12422
7G0,75
12423
12G0,75
12424
18G0,75
12425
25G0,75
12426
2x1
12427
3G1
12428
4G1
12429
5G1
12430
7G1
12431
12G1
12432
18G1
12433
25G1
12434
2x1,5
12435
3G1,5
12436
4G1,5

AWG-No.

20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
16
16
16

Outer
Cop.
approx. mm weight
kg/km
8,3
8,6
9,4
10,1
12,1
14,7
17,3
20,6
8,7
9,0
9,9
10,8
13,0
15,8
17,9
22,8
9,4
9,8
10,8
12,1
14,5
17,4
20,7
24,8
10,2
10,9
12,2

30,0
39,0
52,0
61,0
75,0
130,0
170,0
230,0
39,0
57,0
68,0
79,0
96,0
169,0
224,0
292,0
52,0
67,0
78,0
94,0
122,0
201,0
275,0
364,0
68,0
84,0
104,0

Weight
approx.
kg/km
129,0
150,0
170,0
199,0
235,0
320,0
428,0
503,0
143,0
155,0
190,0
228,0
323,0
410,0
560,0
730,0
150,0
163,0
200,0
239,0
289,0
464,0
628,0
855,0
162,0
187,0
240,0

Continuation

N 20
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-600-Y-CY UL/CSA flexible, number coded, 0,6/1kV, EMC-preferred


type, meter marking

Part no. No.cores x


Jacket cross-sec.
colour mm
black
12372
5G1,5
12373
7G1,5
12374
12G1,5
12375
18G1,5
12376
25G1,5
12377
2x2,5
12378
3G2,5
12379
4G2,5
12380
5G2,5
12381
7G2,5
12382
12G2,5
12383
18G2,5
12384
25G2,5
12385
2x4
12386
3G4
12387
4G4
12388
5G4
12389
7G4
12390
3G6
12391
4G6
12392
5G6
12393
7G6
12394
3G10
12395
4G10
12396
5G10
12397
7G10
12398
3G16
12399
4G16
12400
5G16
12401
7G16
12402
3G25
12403
4G25
12404
5G25
12405
7G25

AWG-No.

16
16
16
16
16
14
14
14
14
14
14
14
14
12
12
12
12
12
10
10
10
10
8
8
8
8
6
6
6
6
4
4
4
4

Outer
Cop.
approx. mm weight
kg/km
13,3
16,0
19,6
23,4
28,2
11,5
12,2
13,4
14,9
17,9
21,9
26,1
31,9
14,3
15,1
16,7
18,6
20,0
17,0
18,7
20,7
23,0
19,6
21,9
24,1
26,8
23,5
26,4
28,8
31,9
28,0
32,5
35,7
39,0

123,0
148,0
274,0
386,0
531,0
110,0
148,0
169,0
220,0
284,0
470,0
572,0
740,0
124,0
178,0
234,0
284,0
321,0
245,0
316,0
442,0
530,0
367,0
549,0
604,0
820,0
653,0
807,0
940,0
1345,0
920,0
1169,0
1420,0
1921,0

Weight
approx.
kg/km
289,0
383,0
592,0
806,0
1241,0
272,0
298,0
345,0
427,0
561,0
857,0
1355,0
1995,0
306,0
391,0
527,0
700,0
920,0
629,0
731,0
1105,0
1465,0
1125,0
1345,0
1635,0
2210,0
1395,0
1870,0
2720,0
3213,0
2465,0
2750,0
3490,0
4980,0


Part no. No.cores x
Jacket cross-sec.
colour mm
grey
12437
5G1,5
12438
7G1,5
12439
12G1,5
12440
18G1,5
12441
25G1,5
12442
2x2,5
12443
3G2,5
12444
4G2,5
12445
5G2,5
12446
7G2,5
12447
12G2,5
12448
18G2,5
12449
25G2,5
12450
2x4
12451
3G4
12452
4G4
12453
5G4
12454
7G4
12455
3G6
12456
4G6
12457
5G6
12458
7G6
12459
3G10
12460
4G10
12461
5G10
12462
7G10
12463
3G16
12464
4G16
12465
5G16
12466
7G16
12467
3G25
12468
4G25
12469
5G25
12470
7G25

AWG-No.

16
16
16
16
16
14
14
14
14
14
14
14
14
12
12
12
12
12
10
10
10
10
8
8
8
8
6
6
6
6
4
4
4
4

Outer
Cop.
approx. mm weight
kg/km
13,3
16,0
19,6
23,4
28,2
11,5
12,2
13,4
14,9
17,9
21,9
26,1
31,9
14,3
15,1
16,7
18,6
20,0
17,0
18,7
20,7
23,0
19,6
21,9
24,1
26,8
23,5
26,4
28,8
31,9
28,0
32,5
35,7
39,0

123,0
180,0
284,0
390,0
521,0
99,0
124,0
170,0
202,0
268,0
423,0
572,0
740,0
156,0
191,0
236,0
303,0
394,0
251,0
319,0
421,0
561,0
371,0
576,0
620,0
842,0
540,0
807,0
1394,0
1605,0
820,0
1169,0
1850,0
2140,0

Weight
approx.
kg/km
289,0
383,0
592,0
806,0
1241,0
272,0
298,0
345,0
427,0
561,0
857,0
1355,0
1995,0
306,0
391,0
527,0
700,0
920,0
629,0
731,0
1105,0
1465,0
1125,0
1345,0
1635,0
2210,0
1395,0
1870,0
2720,0
3213,0
2465,0
2750,0
3490,0
4980,0

Dimensions and specifications may be changed without prior notice. (RN01)

N 21
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ x 1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ
x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQ x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
1)3$(GLWLRQ x1)3$(GLWLRQ x 1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ x1)3$(GLWLRQ
1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQx1)3$(GLWLRQ
Photo: HELUKABEL

NFPA 79 Edition 2007


Challenges and solutions

N 22
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NFPA 79 Edition 2012


Challenges and solutions
The rst edition of the Electrical Code (NEC), also referred to as NFPA 70, was published in 1897. The NEC
is the only code for electrical installations that enjoys
national recognition in the USA. It addresses the causes
of electricity-induced re. The code is updated every
three years, that means in 2011 appeared the edition
of 2012. In Article 670 Industrial Machinery the NEC
refers to the NFPA 79 (Electrical Standard for Industrial
Machinery).
This standard species the safety requirements for
electrical equipment of industrial machinery or industrial manufacturing systems. Manufacturers and operators of plant and machinery have to comply with
this and other standards in order to full their product
liability and satisfy insurance requirements.
Machines commissioned in the USA are always subject
to approval, which can be obtained in two different
ways. One is through a testing institute accredited in
the USA, alternatively the machine concerned is subjected to an acceptance procedure in Germany, for
example. The nal decision on whether a machine is
to be commissioned is always taken by a local inspector, who does not necessarily have to be an expert in
electrical systems. If the inspector is in any doubt as to
whether the machine complies with the relevant US
standards, he may order a temporary stoppage.
The NFPA 79: 2007 allowed for the use of AWM wires in
chapter 12.2.7.3 When part of a listed assembly suitable for the intended application, type AWM shall be
permissible.
However, there are applications for which there had
up to now not been any NFPA 79-relevant wires. This
applies to wires used for power track chains or wires
with special-purpose bodies. There were objections
and protests from the industry in this regard. The
NFPA responded accordingly and appointed an expert
commission. As a result, the NFPA 79: Edition 2012
once again allows for the use of AWM wires under certain conditions. As before, usage is not unrestricted.
Rather, responsibility for their usage now lies with the
manufacturer or builder of the system.
Article 12.2.7.of Edition 2007 was deleted entirely. The
new article 12.9 summarizes all recommendations.

The complete original text:


12.9
12.9.1

Special Cables and Conductors


Other listed cables and conductors shall be permitted
where identied as suitable for the identied use.
12.9.2 Appliance Wiring Material (AWM) shall be permitted
under 12.9.2.1 through 12.9.2.3
12.9.2.1 Where part of an assembly that has been identied for
intended use
12.9.2.2 Where specied for use with approved equipment and
used in accordance with the equipment manufacturers
instructions.
12.9.2.3 Where its construction meets all applicable requirements
of sections 12.2 12.6 with modications as folIows:
(1) Stranded conductors with wire sizes smaller than
those listed in 12.2.2 shall have a minimum of 7
strands.
(2) Conductor insulation and cable jacket materials not
specied in 12.3.1 have ame resistant properties in
compliance with applicable standards for intended
use such as FT2 (horizontal wire) ame test or VW-1
(Vertical Wire) ame test in ANSI/UL 1581-2001,
Reference Standard for Electrical Wires, Cables and
Flexible Cords.
(3) Minimum insulation thickness for single conductor
AWM shall be as specied in 12.3.2. Minimum
insulation thickness for conductors that are part
of a multi conductor jacketed AWM cable shall be
as specied by the AWM Style number and by the
marked voltage rating of the cable.
(4) AWM shall be marked in accordance with 12.4.1,
12.4.3 and 12.4.4. The legend shall include
manufacturers name or trademark, AWM style
number, voltage rating (unless marking is prohibited
by 12.4.2), wire gauge(s), temperature rating and
ame resistance. Additional markings for properties
such as oil, water, UV and chemical resistance
identiers shall be permitted where in compliance
with applicable standards for intended use. Where
markings alone are insufcient to identify for the
intended application, suitable information shall be
included with the technical machine documentation.

Summary
Plant and machinery with certication (e.g. from UL)
can continue to be repaired, modied or upgraded
in accordance with existing rules.
Newly certied plant and machinery can continue
to be constructed in accordance with existing rules.
The certication is recognised.
In certain sectors, new plant and machinery without
certication may need to satisfy tougher requirements for certain cables (e.g. UL Listing). In this case,
consultation is required with the certifying body
concerned.
HELUKABEL recommends in many cases still the use of
UL-listed cables.
The following pages present a broad range of cables
that already meet the requirements of the 2007
Edition of NFPA 79.
If you have any further questions, please contact our
cable experts on +49 (0)7150 9209 -0.

N 23
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NFPA 79 Edition 2012


Challenges and solutions

Flexible Control Cables


TRAYCONTROL 500 &
TRAYCONTROL 500-C
Flexible, extremely oil-resistant control cables for open installation (ER)
UL: TC-ER, PLTC-ER, ITC-ER, MTW, DP-1, WTTC 1000V, OIL RES I & II
CSA: CIC-TC FT4, AWM I/II A/B FT4
See page N 27 - N 28 and N 35 - N 36

TRAYCONTROL 600 &


TRAYCONTROL 600-C
Flexible, oil-resistant TRAY CABLE for open installation (ER)
UL: TC-ER, PLTC-ER, ITC-ER, MTW, DP-1, WTTC 1000V, OIL RES I
CSA: CIC-TC FT4, AWM I/II A/B FT4
See page N 30 - N 31 and N 37

THHN/THWM
Flexible jumper wire
UL: MTW, THHN, THWN, GASOLINE, OIL RES II,
AWM W-51554
See page N 115

Servo and Motor Cables


TOPFLEX 600 VFD
Flexible, extremely oil-resistant motor connection cables for open
installation (ER)
UL: TC-ER, PLTC-ER, ITC-ER, MTW, WTTC 1000V, OIL RES I & II
CSA: CIC-TC FT4, AWM I/II A/B FT4
See page N 137

TOPFLEX 650 VFD


JZ 604 TC & JZ 604-FCY/YCY TC
Flexible, oil-resistant TRAY CABLE for open installation (ER)
UL: TC-ER
See page N 25 - N 26 and N 33 - N 34

Hochexible Steuerleitungen
MULTIFLEX 600 &
MULTIFLEX 600-C
Highly-exible, extremely oil-resistant cables for open installation (ER)
UL: TC-ER, PLTC-ER, ITC-ER, MTW, DP-1, WTTC 1000V, OIL RES I & II
CSA: CIC-TC FT4, AWM I/II A/B FT4
See page N 62 - N 63

Data Cables
TRAYCONTROL 300 &
TRAYCONTROL 300-C
Flexible, extremely oil-resistant data and control cables for open
installation (ER)*
UL: PLTC-ER, ITC-ER, CM, OIL RES I & II;
CSA: CIC-TC FT4, CMG
See page N 38 - N 41

TRAYCONTROL 300 TP &


TRAYCONTROL 300-C TP
Flexible, extremely oil-resistant data and control cables for open
installation (ER)*
UL: PLTC-ER, ITC-ER, CM, OIL RES I & II;
CSA: CIC-TC FT4, CMG
See page N 42 - N 45

Single Conductors
FIVENORM
The jumper wire that meets ve different standards
HAR: H05 V2-K/H07 V2-K;
UL: MTW, AWM Style 10269;
CSA: TEW bzw. AWM I/A/B
See page N 113 - N 114

Flexible, extremely oil-resistant motor connection cables with control


pair for open installation (ER)
UL: TC-ER, PLTC-ER, ITC-ER, MTW, WTTC 1000V, OIL RES I & II
CSA: CIC-TC FT4, AWM I/II A/B FT4
See page N 138

TOPSERV 600 VFD


Highly-exible, extremely oil-resistant motor connection cables for
open installation (ER)
UL: TC-ER, PLTC-ER, ITC-ER, MTW, WTTC 1000V, OIL RES I & II
CSA: CIC-TC FT4, AWM I/II A/B FT4
See page N 139

TOPSERV 650 VFD


Highly-exible, extremely oil-resistant motor connection cables for
open installation (ER)
UL: TC-ER, PLTC-ER, ITC-ER, MTW, WTTC 1000V, OIL RES I & II
CSA: CIC-TC FT4, AWM I/II A/B FT4
See page N 140

HELUKAT Copper Data Cables


HELUKAT 155 UTP 4x2xAWG24/1 UL CMX 444
HELUKAT 200 FTP FLEX 4x2xAWG26/7 UL CMX 444
HELUKAT 300 UTP 4x2xAWG24/1 UL CMX 444
HELUKAT 300 U-STP 4x2xAWG26/7 UL CMX 444
See page R 51 et seq.

Bus Cables
PROFInet Typ A UL CMG or PLTC, CSA FT4
PROFInet Typ B UL CMG or PLTC
PROFInet Typ B SHIPLINE UL CMG or PLTC, CSA FT4
PROFInet Typ C UL CMG
Probus L2 Torsion UL CMX
Probus L2 Festoon UL CMX, CSA FT4
Probus SK inside UL CMG, CSA FT4
Probus SK FRNC UL CM
Probus SK drag chain UL CMX
DeviceNetPVC small UL CMG FT4
DeviceNetPVC thick UL CMG FT4
See Chapter R

* AWG 22 - AWG 16

N 24
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ 604 TC TRAY CABLE PVC power cable, exposed run, 90C,


600V, meter marking


Technical data

Cable structure

Properties

PVC power cable to UL-standard1277


TRAY CABLE
Multinorm
The TRAY CABLE also conforms to the
following standards:
AWM-Style2587 to UL-Std.758 and
CSA C22.2 No210.2 I/II A/B90C600V
Temperature range
dry environment
flexing -5 C to +90 C
fixed installation -25 C to +90 C
wet environment
flexing -5 C to +75 C
fixed installation -25 C to +75 C
Nominal voltage to UL 600 V
Test voltage 3000 V
Breakdown voltage min. 6000V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
7,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors,


according to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Special PVC core insulation class12B to
table50.155 UL-standard1581,
type TFF to UL-Std.66 (AWG20-AWG16),
type THHW to UL-Std.83 ( AWG
 14)
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-lengt
Special PVC outer sheath, to UL-Std.1277
table11.2
Sheath colour black (RAL9005)
with meter marking, change-over in 2011

Material self-extinguishing and flame


retardant
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
JZ 604-FCY TC TRAY CABLE ,
see page N 33
JZ 604-YCY TC TRAY CABLE ,
see page N 34

Application
USA NFPA79, edition 2007 conformant flexible power cables up to 600 V, for all machinery in tool and plant constuction, suitable for installation
in dry, humid and damp environments, in the open and in pipes. For underground installation and for open, unprotected installation from
the cable rack to machines and industrial plants.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
69661
69662
69663
69664
69665
69666
69667
69668
69669
69670
69671
69672
69673
69674
69675
69676
69677
69678
69679
69680
69681
69682
69683
69684
69685
69686
69687
69688

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
9G1
10G1
12G1
18G1
25G1
34G1
50G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
8G1,5
9G1,5
10G1,5
12G1,5
16G1,5
18G1,5
25G1,5
34G1,5
41G1,5
50G1,5
61G1,5

AWG-No. Outer
approx.
mm
18
8,0
18
8,4
18
9,1
18
10,0
18
11,7
18
12,6
18
14,3
18
14,7
18
17,1
18
20,3
18
23,7
18
26,1
16
8,4
16
8,8
16
9,6
16
10,5
16
12,3
16
13,3
16
13,3
16
15,1
16
15,6
16
17,1
16
18,2
16
22,7
16
25,3
16
27,0
16
27,3
16
29,4

Cop.
weight
kg/km
19,2
29,0
39,0
48,0
67,0
84,0
96,0
115,0
173,0
240,0
326,0
480,0
28,8
43,0
58,0
72,0
101,0
115,0
130,0
144,0
173,0
230,0
259,0
360,0
489,0
590,0
720,0
878,0

Weight
approx.
kg/km
72,0
84,0
96,0
114,0
147,0
172,0
206,0
256,0
367,0
477,0
551,0
959,0
88,0
102,0
119,0
144,0
192,0
213,0
261,0
294,0
328,0
402,0
427,0
594,0
714,0
803,0
1021,0
1238,0


Part no.
69689
69690
69691
69692
69693
69694
69695
69696
69697
69698
69699
69700
69701
69702
69703
69704
69705
69706
69707
69708
69709
69710
69711
69712
69713
69714

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
8G2,5
9G2,5
10G2,5
12G2,5
18G2,5
25G2,5
3G4
4G4
5G4
7G4
9G4
12G4
18G4
3G6
4G6
5G6
7G6
3G10
4G10
5G10
7G10

AWG-No. Outer
approx.
mm
14
9,4
14
9,9
14
10,8
14
11,8
14
14,7
14
16,0
14
16,0
14
17,1
14
17,7
14
20,8
14
25,8
12
11,0
12
12,0
12
13,2
12
16,5
12
17,8
12
19,9
12
24,2
10
12,5
10
14,5
10
15,8
10
17,3
8
16,9
8
18,6
8
20,4
8
23,5

Cop.
weight
kg/km
48,0
72,0
96,0
120,0
168,0
192,0
216,0
240,0
288,0
432,0
600,0
115,0
154,0
192,0
269,0
346,0
461,0
691,0
173,0
230,0
288,0
403,0
288,0
384,0
480,0
672,0

Weight
approx.
kg/km
108,0
137,0
157,0
190,0
253,0
339,0
341,0
392,0
470,0
682,0
891,0
187,0
226,0
280,0
390,0
480,0
841,0
981,0
290,0
381,0
465,0
654,0
511,0
584,0
781,0
970,0

Continuation

N 25
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ 604 TC TRAY CABLE PVC power cable, exposed run, 90C,


600V, meter marking

Part no.
69715
69716
69717
69718
69719
69720
69721
69722
69723
69724
69725
69726
69727
69728

No.cores x
cross-sec.
mm
3G16
4G16
5G16
7G16
3G25
4G25
5G25
7G25
3G35
4G35
5G35
3G50
4G50
5G50

AWG-No. Outer
approx.
mm
6
21,0
6
23,9
6
26,3
6
28,8
4
24,9
4
27,2
4
30,3
4
33,1
2
27,1
2
29,8
2
33,0
1
33,2
1
36,7
1
41,5

Cop.
weight
kg/km
461,0
614,0
768,0
1075,0
720,0
960,0
1200,0
1680,0
1008,0
1344,0
1680,0
1440,0
1920,0
2400,0

Weight
approx.
kg/km
651,0
866,0
1117,0
1364,0
1090,0
1421,0
1611,0
1943,0
1734,0
2011,0
2347,0
2041,0
2539,0
2894,0


Part no.
69729
69730
69731
69732
69733
69734
69735
69736
69737

No.cores x
cross-sec.
mm
3G70
4G70
5G70
3G95
4G95
5G95
3G120
4G120
5G120

AWG-No. Outer
approx.
mm
2/0
37,6
2/0
42,0
2/0
47,6
3/0
41,8
3/0
47,0
3/0
52,5
4/0
46,0
4/0
51,5
4/0
56,5

Cop.
weight
kg/km
2016,0
2688,0
3360,0
2736,0
3648,0
4560,0
3456,0
4608,0
5760,0

Weight
approx.
kg/km
2831,0
3494,0
4260,0
5010,0
6104,0
7891,0
5940,0
7604,0
8751,0

Dimensions and specifications may be changed without prior notice. (RN01)

Terminations and straight-through joints


Telephone calbes
Low voltage
Medium voltage
Accessories

You can nd terminations and straight-through joints in our catalogue Cable Accessories.

N 26
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRAYCONTROL 500 flexible, oil-resistant, open installation TC-ER,


PLTC-ER, ITC-ER, NFPA 79 Edition 2007


Technical data

Cable structure

Properties

PVC control cable according to UL Standard


1277
Temperature range
Flexing -5 C to +90 C
Fixed installation -40 C to +90 C
Nominal voltage
TC 600 V
AWM 1000 V
TC Wind Turbine (WTTC) 1000 V
Testvoltage 3000V
Minimum bending radius
Flexing 4x cable
Insulation resistance
Min. 20 MOhm x km 
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper conductor, fine wire stranded


Special PVC core insulation with transparent
nylon skin
Black cores with continuous white
numbering
Green-yellow earth core in the outer layer,
3 cores and more
Cores stranded in layers with optimal
lay-lengths
Separator
Special PVC outer jacket
Sheath colour - grey (RAL 7001)
With lenght marking in feet 

Self-extinguishing and flame retardant in


accordance with CSA FT4
The materials used in manufacture are free
of silicone, cadmium and substances that
impair paint wetting
Tests
UL: TC-ER, PLTC-ER (AWG 18 - AWG 12),
ITC-ER (AWG 18 - AWG 12), MTW, NFPA 79
2007, WTTC 1000V, DP-1, OIL RES I & II,
90 C dry / 75 C wet, Class 1 Div. 2 per NEC
Art 336, 392, 501, crush impact test in
accordance with UL 1277
CSA: c(UL) CIC-TC FT4, CSA AWM I/II A/B FT4


Note

Advantages
Highly-flexible, easy to install
Available on request
withblue cores(DC)
with red cores(AC)
Black or TPE outer sheath

Application
HELUKABEL TRAYCONTROL 500 is a flexible, oil-resistant control cable. The special combination of TC-ER, PLTC-ER and ITC-ER allows this cable
to be used as a connecting cable for industrial plant and machinery in accordance withNFPA 79 Edition 2007. Approved for open, unprotected
installation in cable trays to the machine. Its outstanding oil resistance (OIL RES I & II) guarantees a long service life for industrial applications
in dry, damp and wet environments. Recommended applications: production lines, bottling plants, machine construction, switch cabinets,
conveyor systems, packaging machines, automotive industry.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
63079
63080
63081
63082
63083
63084
63085
63086
63087
63088
63089
63090
63091
63092
63093
63094
63095
63096
63097
63098
63099
63100
63101
63102
63103
63104
63105
63106

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
9G0,5
12G0,5
18G0,5
25G0,5
2x1
3G1
4G1
5G1
7G1
9G1
10G1
12G1
15G1
16G1
18G1
19G1
25G1
27G1
34G1
37G1
41G1
50G1
61G1

AWG-No. Outer
approx.
mm
20
6,4
20
6,7
20
7,2
20
7,8
20
8,4
20
9,6
20
10,7
20
12,4
20
14,9
18
7,0
18
7,1
18
8,0
18
8,6
18
9,3
18
10,7
18
11,6
18
11,9
18
13,2
18
13,3
18
366,0
18
14,7
18
17,0
18
17,4
18
19,3
18
19,8
18
20,7
18
23,5
18
24,9

Cop.
weight
kg/km
10,0
14,0
19,0
24,0
34,0
43,0
58,0
86,0
120,0
19,0
29,0
38,0
48,0
67,0
86,0
96,0
115,0
144,0
154,0
14,6
182,0
240,0
259,0
326,0
355,0
394,0
480,0
586,0

Weight
approx.
kg/km
58,0
61,0
76,0
89,0
120,0
201,0
250,0
295,0
362,0
68,0
88,0
98,0
116,0
149,0
186,0
199,0
245,0
292,0
306,0
173,0
384,0
451,0
521,0
625,0
684,0
744,0
933,0
1095,0


Part no.
63107
63108
63109
63110
63111
63112
63113
63114
63115
63116
63117
63118
63119
63120
63121
63122
63123
63124
63125
63126
63127
63128
63129
63130
63131
63132
63133
63164

No.cores x
cross-sec.
mm
2x1,5
3G1,5
4G1,5
5G1,5
4G2,5
6G1,5
7G1,5
8G1,5
9G1,5
10G1,5
12G1,5
14G1,5
15G1,5
16G1,5
18G1,5
19G1,5
20G1,5
25G1,5
27G1,5
30G1,5
34G1,5
40G1,5
41G1,5
50G1,5
61G0,5
2x2,5
3G2,5
5G2,5

AWG-No. Outer
approx.
mm
16
7,7
16
8,1
16
8,8
16
9,5
14
9,8
16
10,0
16
10,3
16
10,9
16
11,9
16
12,9
16
14,2
16
14,5
16
15,2
16
15,9
16
16,4
16
16,5
16
17,0
16
18,6
16
19,0
16
19,6
16
20,5
16
22,9
16
23,4
16
25,1
16
27,2
14
8,6
14
8,9
14
10,6

Cop.
weight
kg/km
29,0
43,0
58,0
72,0
96,0
86,0
101,0
115,0
130,0
144,0
173,0
202,0
216,0
14,0
259,0
274,0
288,0
360,0
389,0
432,0
490,0
576,0
590,0
720,0
878,0
48,0
72,0
120,0

Weight
approx.
kg/km
80,0
86,0
115,0
126,0
141,0
164,0
171,0
201,0
237,0
259,0
301,0
365,0
379,0
61,0
443,0
458,0
491,0
564,0
629,0
701,0
775,0
946,0
967,0
1137,0
1345,0
100,0
112,0
152,0

Continuation

N 27
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRAYCONTROL 500 flexible, oil-resistant, open installation TC-ER,


PLTC-ER, ITC-ER, NFPA 79 Edition 2007

Part no.
63165
63166
63167
63168
63169
63170
63171
63172
63173
63174
63175
63176
63177
63178
63179
63180
63181
63182
63183
63184
63185
63186
63187

No.cores x
cross-sec.
mm
6G2,5
7G2,5
9G2,5
10G2,5
12G2,5
16G2,5
18G2,5
19G2,5
25G2,5
2x4
3G4
4G4
5G4
6G4
7G4
9G4
12G4
16G4
19G4
20G4
25G4
2x6
3G6

AWG-No. Outer
approx.
mm
14
11,2
14
11,6
14
14,3
14
15,5
14
15,9
14
17,6
14
18,4
14
18,6
14
22,2
14
9,5
14
10,6
14
11,5
14
12,6
12
14,1
12
14,6
12
16,9
12
18,9
12
19,8
12
23,1
12
24,3
12
26,3
10
11,9
10
12,6

Cop.
weight
kg/km
144,0
168,0
216,0
240,0
288,0
384,0
432,0
456,0
600,0
76,8
115,0
154,0
192,0
230,0
269,0
346,0
461,0
614,0
768,0
768,0
960,0
115,0
173,0

Weight
approx.
kg/km
205,0
216,0
312,0
378,0
434,0
550,0
616,0
634,0
817,0
132,0
177,0
201,0
274,0
315,0
353,0
476,0
613,0
783,0
918,0
961,0
1236,0
213,0
283,0


Part no.
63188
63189
63190
63191
63192
63193
63194
63195
63196
63197
63198
63199
62802
62803
62804
62805
62806
62807
62808
62809
62810
62811
62812

No.cores x
cross-sec.
mm
4G6
5G6
7G6
9G6
12G6
19G6
3G10
4G10
5G10
3G16
4G16
5G16
3G25
4G25
5G25
3G35
4G35
5G35
4G42,3
4G52,9
4G67,3
4G84,4
4G106,7

AWG-No. Outer
approx.
mm
10
14,7
10
16,0
10
17,4
10
20,4
10
23,9
10
27,9
8
17,0
8
19,7
8
21,7
6
19,5
6
21,9
6
24,0
4
24,3
4
27,1
4
29,3
2
27,9
2
31,4
2
34,0
1
34,8
1/0
37,9
2/0
41,3
3/0
48,6
4/0
51,2

Cop.
weight
kg/km
230,0
288,0
403,0
518,0
691,0
1094,0
288,0
384,0
480,0
461,0
614,0
768,0
720,0
960,0
1200,0
1008,0
1344,0
1680,0
1624,0
2031,0
2584,0
3256,0
4097,0

Weight
approx.
kg/km
387,0
473,0
607,0
771,0
1061,0
1528,0
420,0
662,0
784,0
701,0
908,0
1149,0
1061,0
1366,0
1631,0
1480,0
1922,0
2363,0
2397,0
2938,0
3559,0
4181,0
5747,0

Dimensions and specifications may be changed without prior notice. (RN01)

N 28
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRAYCONTROL 530 flexible TC-ER control cable with coloured cores




Technical data

Cable structure

Properties

Flexible PVC tray cable to UL Standard 1277


Temperature range
flexing -5 C to +90 C
fixed installation -40 C to +90 C
Nominal voltage
TC 600 V
AWM 1000 V
TC Wind Turbine (WTTC) 1000 V
Test voltage
3000 V
Minimum bending radius
Approx. 5x cable 

Bare copper conductor, fine wire stranded


with AWG dimensions
Special PVC core insulation withclear nylon
jacket
Blue coreswith continuous numberingplus
green/yellow ground, 3 cores and more>
second core is blue-white
Conductor cabled with non-wicking fillers
Separator
Sheath colour -grey (RAL 7001)

Material self-extinguishing and flame


retardant to UL-Standard in accordance CSA
FT4
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Tests
UL: TC-ER, PLTC-ER (AWG 18 - AWG 12),
ITC-ER (AWG 18 - AWG 12), MTW, NFPA 79
2007, WTTC 1000V, DP-1, OIL RES I & II,
90Cdry / 75C wet, Class 1 Div. 2 per NEC
Art 336, 392, 501, crush impact testin
accordance withUL 1277
CSA:
c(UL) CIC-TC FT4
CSA AWM I/II
A/B FT4


Note

Available on request
with red, black, yellow or orange cores
Black or TPE outer sheath


Application
TRAYCONTROL 530 is a flexible, oil-resistant control cable. The special combination of TC-ER, PLTC-ER and ITC-ER allows this cable to be used
as a connecting cable for AC, DC or control wiring in accordance with NFPA 79 Edition 2007. Approved for open, unprotected installation in
cable trays to the machine. Its outstanding oil resistance (OIL RES I & II) guarantees a long service life for industrial applications in dry, damp
and wet environments.
Recommended Applications: automotive industry, machine tool, production lines
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
66840
66841
66842
66843
66844
66845
66846
66847
66848
66849
66850
66851
66852
66853
66854
66855
66856
66857
66858
66859
66860
66861

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
9G1
10G1
12G1
15G1
16G1
18G1
19G1
25G1
27G1
33G1
34G1
41G1
42G1
49G1
50G1
61G1
65G1

AWG-No. Outer
approx.
mm
18
7,0
18
7,1
18
8,0
18
8,6
18
9,3
18
10,7
18
11,6
18
11,9
18
13,2
18
13,3
18
14,6
18
14,7
18
17,0
18
17,4
18
18,7
18
19,3
18
20,7
18
20,8
18
23,0
18
23,5
18
24,9
18
25,6

Cop.
weight
kg/km
19,0
29,0
38,0
48,0
67,0
86,0
96,0
115,0
144,0
154,0
173,0
182,0
240,0
259,0
317,0
326,0
394,0
403,0
470,0
480,0
624,0
624,0

Weight
approx.
kg/km
68,0
88,0
98,0
116,0
149,0
186,0
199,0
245,0
292,0
306,0
366,0
384,0
451,0
521,0
590,0
625,0
744,0
758,0
917,0
933,0
1095,0
1125,0


Part no.
66862
66863
66864
66865
66866
66867
66868
66869
66870
66871
66872
66873
66874
66875
66876
66877
66878
66879
66880
66881
66882
66883

No.cores x
cross-sec.
mm
2x1,32
3G1,32
4G1,32
5G1,32
7G1,32
9G1,32
10G1,32
12G1,32
15G1,32
16G1,32
18G1,32
19G1,32
25G1,32
27G1,32
33G1,32
34G1,32
41G1,32
42G1,32
49G1,32
50G1,32
61G1,32
65G1,32

AWG-No. Outer
approx.
mm
16
7,5
16
7,8
16
8,5
16
9,3
16
10,1
16
11,7
16
12,4
16
12,9
16
15,0
16
15,2
16
15,9
16
16,0
16
18,6
16
19,0
16
20,4
16
20,5
16
23,4
16
24,1
16
25,5
16
25,6
16
27,2
16
28,5

Cop.
weight
kg/km
25,0
38,0
51,0
63,0
89,0
114,0
127,0
152,0
190,0
203,0
228,0
241,0
317,0
342,0
418,0
431,0
520,0
532,0
621,0
634,0
773,0
824,0

Weight
approx.
kg/km
80,0
86,0
115,0
126,0
171,0
237,0
259,0
301,0
379,0
405,0
443,0
458,0
564,0
629,0
758,0
775,0
967,0
972,0
1132,0
1137,0
1345,0
1376,0

Dimensions and specifications may be changed without prior notice. (RN01)

N 29
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRAYCONTROL 600 flexible, oil-resistant, open installation (TC-ER),


NFPA 79 Edition 2007


Technical data

Cable structure

Properties

PVC-power cable according to UL Standard


1277
Temperature range
UL / CSA TC -40 C to +90 C
UL / AWM -40 C to +90 C
Nominal voltage
TC 600 V
AWM 1000 V
WTTC 1000 V
Test voltage
3000 V
Minimum bending radius
Approx. 5x cable
Insulation resistance
Min. 20 MOhm x km
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper conductor, fine wire stranded


with AWG dimensions
Special PVC core insulation with transparent
nylon skin
Black cores with continuous white
numbering
Green-yellow earth core in the outer layer,
3 cores and more
Cores stranded in layers with optimal
lay-lengths
Separator
Special PVC outer jacket
Sheath colour -black (RAL 9005)
With lenght marking in feet


Material self-extinguishing and flame


retardant to UL-Standard in accordance CSA
FT4
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
UV-resistant
Tests
UL: TC-ER, PLTC-ER (AWG 18 - AWG 12),
ITC-ER (AWG 18 - AWG 12), UL 1277, UL Type
WTTC, UL TypeMTW,NFPA 79 2007,
Oil Res I (Oil Res II also available), 90 C dry
/ 75 C wet 
CSA: c(UL) CIC-TC FT4
CSA AWM I/II A/B FT4


Note

G = with green-yellow earth core


x = without earth core (OZ)
Advantages
TC-ER, Tray Cable Exposed Run
simple Installation
outstanding flexibility


Application
USA NFPA79, edition 2007 conformant flexible power cables up to 600 V (WTTC 1000 V), for all machinery in tool and plant constuction,
suitable for installation in dry, humid and damp environments, in the open and in pipes. For underground installation and for open,
unprotected installation from the cable rack to machines and industrial plants.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
62902
62903
62904
62905
62906
62907
62908
62909
62910
62911
62912
62913
62914
62915
62916
62940
62917
62941
62918
62942
62919
62920
62970
62971
62972
62973
62974
62975
62976
62977

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
9G1
10G1
12G1
15G1
16G1
18G1
19G1
25G1
27G1
34G1
34G1
37G1
40G1
41G1
41G1
50G1
61G1
2x6
3G6
4G6
5G6
7G6
9G6
12G6
19G6

AWG-No. Outer
approx.
mm
18
7,0
18
7,1
18
8,0
18
8,6
18
9,3
18
10,7
18
11,6
18
11,9
18
13,2
18
13,3
18
14,6
18
14,7
18
17,0
18
17,4
18
19,3
16
20,5
18
19,8
16
22,9
18
20,7
16
23,4
18
23,5
18
24,9
10
11,9
10
12,6
10
14,7
10
16,0
10
17,4
10
20,4
10
23,9
10
27,9

Cop.
weight
kg/km
19,0
29,0
39,0
48,0
67,0
86,0
96,0
115,0
144,0
154,0
173,0
182,0
240,0
259,0
326,0
431,0
355,0
507,0
394,0
519,0
480,0
586,0
115,0
173,0
230,0
288,0
403,0
518,0
691,0
1094,0

Weight
approx.
kg/km
68,0
88,0
97,0
116,0
147,0
186,0
199,0
250,0
292,0
306,0
365,0
384,0
480,0
521,0
625,0
775,0
684,0
946,0
744,0
967,0
933,0
1095,0
213,0
283,0
387,0
473,0
607,0
771,0
1061,0
1528,0


Part no.
62978
62979
62980
62981
62982
62983
62984
62985
62986
62987
62988
62921
62922
62923
62924
62925
62926
62927
62928
62929
62930
62931
62932
62933
62934
62935
62936
62937
62938
62939

No.cores x
cross-sec.
mm
4G10
5G10
3G16
4G16
5G16
3G25
4G25
5G25
3G35
4G35
5G35
2x1,32
3G1,32
4G1,32
5G1,32
6G1,32
7G1,32
8G1,32
9G1,32
10G1,32
12G1,32
14G1,32
15G1,32
16G1,32
18G1,32
19G1,32
20G1,32
25G1,32
27G1,32
30G1,32

AWG-No. Outer
approx.
mm
8
19,7
8
21,7
6
19,5
6
21,9
6
24,0
4
24,3
4
27,1
4
29,3
2
27,9
2
31,4
2
34,0
16
7,5
16
7,8
16
8,5
16
9,3
16
10,0
16
10,1
16
10,9
16
11,7
16
12,4
16
12,9
16
14,5
16
15,0
16
15,2
16
15,9
16
16,0
16
16,5
16
18,6
16
19,0
16
19,6

Cop.
weight
kg/km
384,0
480,0
461,0
614,0
768,0
720,0
960,0
1200,0
1008,0
1344,0
1680,0
25,0
38,0
51,0
63,0
76,0
89,0
101,0
114,0
127,0
152,0
177,0
190,0
203,0
228,0
241,0
253,0
317,0
342,0
380,0

Weight
approx.
kg/km
615,0
768,0
700,0
907,0
1100,0
1061,0
1366,0
1631,0
1480,0
1922,0
2360,0
80,0
86,0
120,0
130,0
164,0
188,0
201,0
238,0
259,0
301,0
356,0
379,0
405,0
430,0
450,0
481,0
564,0
629,0
701,0

Continuation

N 30
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRAYCONTROL 600 flexible, oil-resistant, open installation (TC-ER),


NFPA 79 Edition 2007

Part no.
62943
62944
62945
62946
62947
62948
62949
62950
62951
62952
62953
62954
62955
62956
62957
62958
62959
62960

No.cores x
cross-sec.
mm
50G1,32
61G1,32
2x2,08
3G2,08
4G2,08
5G2,08
6G2,08
7G2,08
9G2,08
10G2,08
12G2,08
16G2,08
18G2,08
19G2,08
25G2,08
2x3,31
3G3,31
4G3,31

AWG-No. Outer
approx.
mm
16
25,1
16
27,2
14
8,6
14
8,9
14
9,8
14
10,6
14
11,6
14
11,9
14
13,5
14
15,5
14
15,9
14
17,6
14
18,3
14
18,5
14
21,6
12
9,5
12
10,0
12
10,9

Cop.
weight
kg/km
634,0
773,0
40,0
60,0
80,0
100,0
120,0
140,0
180,0
200,0
240,0
319,0
359,0
380,0
500,0
63,0
95,0
127,0

Weight
approx.
kg/km
1137,0
1345,0
100,0
117,0
141,0
152,0
216,0
255,0
312,0
378,0
434,0
550,0
616,0
634,0
817,0
132,0
177,0
201,0


Part no.
62961
62962
62963
62964
62965
62966
62967
62968
62969
62989
62990
62991
62992
62993
62994
62995
62996

No.cores x
cross-sec.
mm
5G3,31
6G3,31
7G3,31
9G3,31
12G3,31
16G3,31
19G3,31
20G3,31
25G3,31
4G42,3
4G52,9
4G67,3
4G84,4
4G106,7
4G128,4
4G181,9
4G257,6

AWG-No. Outer
approx.
mm
12
11,9
12
13,0
12
13,1
12
15,9
12
17,8
12
19,8
12
20,8
12
21,9
12
25,3
1
34,8
1/0
37,9
2/0
41,3
3/0
48,6
4/0
51,2
250 kcmil
55,0
350 kcmil
63,5
500 kcmil
73,7

Cop.
weight
kg/km
159,0
191,0
222,0
286,0
381,0
508,0
604,0
636,0
794,0
1624,0
2031,0
2584,0
3256,0
4097,0
4931,0
6985,0
9892,0

Weight
approx.
kg/km
274,0
315,0
353,0
476,0
613,0
783,0
918,0
916,0
1286,0
2397,0
2938,0
3569,0
4181,0
5747,0
7591,0
8299,0
11549,0

Dimensions and specifications may be changed without prior notice. (RN01)

Bundling, binding, fastening


Plastic helix
Cable tie
Hook and loop cable tie
Mounting block

You can nd bundling, binding, fastening in our catalogue Cable Accessories.

N 31
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRAYCONTROL 670 HDP / 670-C HDP flexible,


oil-resistant, open installation (TC-ER), NFPA 79 Edition 2007


Technical data

Cable structure

Properties

TPE motor supply cable according to UL


1277
Temperature range
Flexing -40C bis +105C
Nominal voltage
TC 600 V
AWM 1000 V
TC Wind Turbine (WTTC) 1000 V
Test voltage 4000 V
Minimum bending radius
7,5 cable
Coupling resistance (-C-type)
Max. 250 Ohm/km

Tinned copper conductor, fine wire


stranded with AWG measures
Special PVC core insulation with transparent
nylon skin
Black cores with continuous white
numbering
Green-yellow earth core in the outer layer
Cores stranded in layers with optimal
lay-lenghts
Separator
Special TPE outer jacket
Sheath colour orange (RAL 2003)
With length marking in feet
C-Type
Screening with braid of tinned copper
wires, optimal coverage, approx. 85%


Self-extinguishing and flame retardant in


accordance with CSA FT4
The materials used in manufacture are free
of silicone, cadmium and substances that
impair paint wetting
Tests
UL:
TC-ER, WTTC, MTW, NFPA 79 2007, UL 1277,
UL AWM 105C, OIL RES I & II, 75 C wet
Bus Drop Cable Class I Div 2 per NEC Art.
336, 318, 501
CSA:
c (UL) CIC-TC FT4,
AWM I/II A/B FT4


Note

HDP =Heavy Duty Power 

Application
HELUKABEL TRAYCONTROL 670 HDP / 670-C-HDP are multi-conductor severe duty motor supply cables with Bus Drop, UL TC-ER and
CSA CIC/TC approval. Superior oil performance for long cable life and permitted to be used in hazardous (classified) locations Class I Div 2
per NEC 336, 318 and 501. Special extruded jacket and fine copper stranding approved for exposed run, pipes and burial installation. Excellent
flexibility and easier to pull than standard tray cables. Suitable for installation in dry, humid and damp environments, in the open unprotected
installation from the cable
tray to machines.
Recommended Applications: Motor connections in industrial and automation environments, machine tool, automotive and renewable
energies
= The product conforms to EC Low-Voltage Directive 2006/95/EG


TRAYCONTROL 670 HDP


Part no.
66820
66821
66822
66823
66824
66825
66826
66827
66828

No.cores x
cross-sec.
mm
4x1
4G1,32
4G2,08
4G3,31
4G6
4G10
4G16
4G25
4G35

AWG-No. Outer
approx.
mm
18
8,4
16
9,2
14
10,0
12
11,2
10
15,2
8
19,3
6
22,4
4
26,7
2
31,5

Cop.
weight
kg/km
39,0
51,0
80,0
127,0
230,0
384,0
614,0
960,0
1344,0

Weight
approx.
kg/km
103,0
133,0
170,0
229,0
393,0
626,0
885,0
1301,0
1983,0

TRAYCONTROL 670-C HDP


Part no.
66829
66830
66831
66832
66833
66834
66835
66836
66837

No.cores x
cross-sec.
mm
4x1
4G1,32
4G2,08
4G3,31
4G6
4G10
4G16
4G25
4G35

AWG-No. Outer
approx.
mm
18
9,8
16
10,5
14
11,7
12
12,8
10
16,9
8
22,1
6
26,2
4
30,8
2
35,0

Cop.
weight
kg/km
52,0
72,0
115,0
179,0
256,0
426,0
657,0
1026,0
1412,0

Weight
approx.
kg/km
133,0
159,0
222,0
283,0
460,0
741,0
1059,0
1497,0
2058,0

Dimensions and specifications may be changed without prior notice. (RN01)

N 32
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ 604-FCY TC TRAY CABLE PVC power cable, exposed run,


screened, NFPA 79 Edition 2007, 90C, 600V, EMC-preferred type, meter marking


Technical data

Cable structure

Properties

PVC power cable, screened


toUL-standard1277 TRAY CABLE
Multinorm
AWM-Style2587 to UL-Std.758 and
CSA C22.2 No210.2 I/II A/B90 C 600V
Temperature range
dry environment
flexing -5 C to +90 C
fixed installation -25 C to +90 C
wet environment
flexing -5 C to +75 C
fixed installation -25 C to +75 C
Nominal voltage to UL 600 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
10x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, fine wire conductors,


according to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Spezial PVC core insulation class12B to
table50.155 UL-standard1581,
type TFF to UL-Std.66 (AWG 20-AWG 16),
type THHW to UL-Std. 83 ( AWG 14)
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-lenght
Special separation foil
Tinned copper braided screening, approx.
85% coverage
Special PVC outer sheath, to UL-Std.1277
table11.2
Sheath colour black (RAL 9005)
with meter marking, change-over in 2011

Material self-extinguishing and flame


retardant to CSA FT4
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
To optimise the EMC features we
recommend a large round contact of the
copper braiding on both ends.
unscreened analogue type:
JZ 604 TC TRAY CABLE, see page N 25

Application
USA NFPA79, edition 2007 conformant flexible power cables up to 600 V, for all machinery in tool and plant constuction, suitable for installation
in dry, humid and damp environments, in the open and in pipes. For underground installation and for open, unprotected installation from
the cable rack to machines and industrial plants.
EMC = Electromagnetic compatibillity
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
69750
69751
69752
69753
69754
69755
69756
69757
69758
69759
69760
69761
69762
69763
69764
69765
69766
69767
69768
69769
69770
69771
69772
69773
69774
69775
69776
69777
69778
69779

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
9G1
10G1
12G1
18G1
25G1
34G1
50G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
8G1,5
9G1,5
10G1,5
12G1,5
16G1,5
18G1,5
25G1,5
34G1,5
41G1,5
50G1,5
61G1,5
2x2,5
3G2,5

AWG-No. Outer
approx.
mm
18
8,6
18
9,0
18
9,7
18
10,5
18
12,2
18
13,2
18
15,0
18
15,4
18
17,8
18
21,9
18
24,5
18
26,2
16
9,0
16
9,4
16
10,2
16
11,1
16
12,9
16
14,5
16
14,5
16
15,8
16
16,2
16
17,9
16
18,9
16
22,3
16
24,9
16
26,7
16
33,7
16
36,0
14
10,0
14
10,5

Cop.
weight
kg/km
50,0
60,0
71,0
88,0
111,0
139,0
150,0
184,0
260,0
349,0
486,0
625,0
63,0
80,0
97,0
119,0
147,0
170,0
182,0
193,0
267,0
315,0
374,0
526,0
629,0
801,0
885,0
1100,0
96,0
144,0

Weight
approx.
kg/km
151,0
164,0
200,0
229,0
306,0
371,0
411,0
460,0
624,0
845,0
984,0
1096,0
161,0
181,0
240,0
274,0
367,0
431,0
437,0
511,0
598,0
630,0
787,0
1240,0
1401,0
2671,0
3614,0
4089,0
269,0
294,0


Part no.
69780
69781
69782
69783
69784
69785
69786
69787
69788
69789
69790
69791
69792
69793
69794
69795
69796
69797
69798
69799
69800
69801
69802
69803

No.cores x
cross-sec.
mm
4G2,5
5G2,5
7G2,5
8G2,5
9G2,5
10G2,5
12G2,5
18G2,5
25G2,5
3G4
4G4
5G4
7G4
9G4
12G4
18G4
3G6
4G6
5G6
7G6
3G10
4G10
5G10
7G10

AWG-No. Outer
approx.
mm
14
11,4
14
12,4
14
15,3
14
16,5
14
16,5
14
17,9
14
18,4
14
22,4
14
26,5
12
11,6
12
12,6
12
14,5
12
17,1
12
18,4
12
20,5
12
25,0
10
13,8
10
15,1
10
16,4
10
18,0
8
17,6
8
19,3
8
22,1
8
24,2

Cop.
weight
kg/km
148,0
181,0
255,0
285,0
309,0
340,0
441,0
570,0
738,0
174,0
230,0
273,0
316,0
402,0
507,0
751,0
240,0
305,0
439,0
505,0
350,0
535,0
592,0
810,0

Weight
approx.
kg/km
341,0
420,0
551,0
583,0
593,0
631,0
847,0
1336,0
1921,0
381,0
504,0
692,0
908,0
1104,0
1497,0
2104,0
623,0
729,0
1082,0
1414,0
1108,0
1324,0
1596,0
2186,0

Dimensions and specifications may be changed without prior notice. (RN01)

N 33
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ 604-YCY TC TRAY CABLE PVC power cable, exposed


run, screened, NFPA 79 Edition 2007, 90C, 600V, EMC-preferred type, meter
marking


Technical data

Cable structure

Properties

PVC power cable, screened to


UL-standard1277 TRAY CABLE
Multinorm
also conforms to the following standards:
AWM-Style2587 to UL-Std.758
(cUL) and CSA type TC FT4 toC22.2 no230,
CSA C22.2 No210.2 I/II A/B90 C 600V FT4
Temperature range
dry environment
flexing -5 C to +90 C
fixed installation -25 C to +90 C
wet environment
flexing -5 C to +75 C
fixed installation -25 C to +75 C
Nominal voltage to UL 600 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
10x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, fine wire conductors,


according to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Spezial PVC core insulation class 12B to
table50.155 UL-standard1581,
type TFF to UL-Std.66 (AWG 20-AWG 16),
type THHW to UL-Std.83 (AWG 14)
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-lenght
PVC-inner sheath, to UL-Std.1277
table11.2
Tinned copper braided screening, approx.
85% coverage
Special PVC outer sheath, to UL-Std.1277
table11.2,
Sheath colour black (RAL 9005)
with meter marking, change-over in 2011

Material self-extinguishing and flame


retardant to CSA FT4
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
JZ 604 TC TRAY CABLE, see page N 25

Application
UL-approved, flexible high current cables for use up to 600 V, for all machines, tools and installation work. Suitable for use in dry, damp and
wet areas, outside, in cable ducts, open cable trays. Also in pipes, in the ground and for open installation in machinery and industrial areas.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
69804
69805
69806
69807
69808
69809
69810
69811
69812
69813
69814
69815
69816
69817
69818
69819
69820
69821

No.cores x
cross-sec.
mm
3G16
4G16
5G16
7G16
3G25
4G25
5G25
7G25
3G35
4G35
5G35
3G50
4G50
5G50
3G70
4G70
5G70
3G95

AWG-No. Outer
approx.
mm
6
25,2
6
27,8
6
31,2
6
34,5
4
29,0
4
32,4
4
34,2
4
40,3
2
32,4
2
36,2
2
40,5
1
40,4
1
45,5
1
50,0
2/0
47,1
2/0
51,1
2/0
56,0
3/0
50,1

Cop.
weight
kg/km
653,0
807,0
940,0
1345,0
920,0
1169,0
1420,0
1921,0
1250,0
1680,0
2020,0
1887,0
2370,0
2880,0
2516,0
3257,0
4032,0
3086,0

Weight
approx.
kg/km
1385,0
1861,0
2614,0
3211,0
2455,0
2721,0
3490,0
4960,0
3130,0
4100,0
4921,0
4560,0
5761,0
7186,0
5580,0
7387,0
9290,0
8520,0


Part no.
69822
69823
69824
69825
69826

No.cores x
cross-sec.
mm
4G95
5G95
3G120
4G120
5G120

AWG-No. Outer
approx.
mm
3/0
55,0
3/0
60,5
4/0
54,0
4/0
59,5
4/0
64,5

Cop.
weight
kg/km
4060,0
5244,0
4176,0
5231,0
6624,0

Weight
approx.
kg/km
10200,0
13800,0
11090,0
13620,0
15420,0

Dimensions and specifications may be changed without prior notice. (RN01)

N 34
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRAYCONTROL 500-C flexible, oil-resistant, screened, EMC-preferred


type, open installation TC-ER, PLTC-ER, ITC-ER, NFPA 79 Edition 2007


Technical data

Cable structure

Properties

PVC control cable according to UL Standard


1277
Temperature range
Flexing -5 C to +90 C
Fixed installation -40 C to +90 C
Nominal voltage
TC 600 V
AWM 1000 V
TC Wind Turbine (WTTC) 1000 V
Test voltage 3000 V
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
Flexing 6x cable
Insulation resistance
Min. 20 MOhm x km
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)


Bare copper conductor, fine wire stranded


Special PVC core insulation with transparent
nylon skin
Black cores with continuous white
numbering
Green-yellow earth core in the outer layer,
3 cores and more
Cores stranded in layers with optimal
lay-lengths
Separating foil
Braided screening of tinnedcopper wires,
coverage approx. 85%
Separator
Special PVC outer jacket
Sheath colour - grey (RAL 7001)
With lenght marking in feet


Self-extinguishing and flame retardant in


accordance with CSA FT4
The materials used in manufacture are free
of silicone, cadmium and substances that
impair paint wetting
Tests
UL: TC-ER, PLTC-ER (AWG 18 - AWG 12),
ITC-ER (AWG 18 - AWG 12), MTW, NFPA 79
2007, WTTC 1000V, DP-1, OIL RES I & II,
90C dry / 75 C wet, Class 1 Div. 2 per
NEC Art 336, 392, 501, crush impact test
in accordance with UL 1277
CSA: c(UL) CIC-TC FT4, CSA AWM I/II A/B FT4


Note

Advantages
Highly-flexible, easy to install
Available on request
withblue cores(DC)
with red cores(AC)
Black or TPE outer sheath

Application
HELUKABEL TRAYCONTROL 500-Cis a flexible, screened and oil-resistant control cable. The special combination of TC-ER, PLTC-ER and ITC-ER
allows this cable to be used as a connecting cable for industrial plant and machinery in accordance with NFPA 79 2007. Approved for open,
unprotected installation in cable trays to the machine. Its outstandingoil resistance (OIL RES I& II) guarantees a long servicelife for industrial
applications in dry, damp and wet environments. Recommendedapplications: production lines, bottling plants, machine construction, switch
cabinets, conveyor systems, packaging machines, automotive industry.
EMC= Electromagnetic compatibility. To optimise EMC characteristics, we recommend a large contact area for the copper braiding around
the entire circumference on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
62813
62814
62815
62816
62817
62818
62819
62820
62821
62822
62823
62824
62825
62826
62827
62828
62829
62830
62831
62832
62833
62834
62835
62836
62837
62838
62839
62840

No.cores x
cross-sec.
mm
2x0,5
3G0,5
7G0,5
12G0,5
25G0,5
2x1
3G1
4G1
5G1
7G1
9G1
10G1
12G1
15G1
18G1
19G1
25G1
3G1,5
4G1,5
5G1,5
6G1,5
7G1,5
9G1,5
10G1,5
12G1,5
15G1,5
18G1,5
19G1,5

AWG-No. Outer
approx.
mm
20
7,0
20
7,6
20
9,4
20
11,0
20
16,1
18
8,1
18
8,2
18
8,8
18
9,4
18
10,1
18
11,4
18
11,6
18
12,9
18
14,8
18
15,7
18
15,7
18
17,7
16
8,9
16
9,6
16
10,3
16
10,5
16
11,3
16
12,6
16
12,9
16
15,1
16
16,4
16
17,3
16
17,6

Cop.
weight
kg/km
35,0
42,0
69,0
108,0
240,0
50,0
60,0
71,0
88,0
111,0
140,0
150,0
184,0
207,0
260,0
280,0
349,0
74,0
90,0
104,0
120,0
134,0
165,0
180,0
244,0
270,0
319,0
327,0

Weight
approx.
kg/km
95,0
115,0
164,0
266,0
435,0
110,0
118,0
136,0
148,0
192,0
244,0
283,0
329,0
377,0
435,0
443,0
571,0
144,0
172,0
188,0
203,0
244,0
308,0
346,0
423,0
441,0
512,0
503,0


Part no.
62841
62842
62843
62844
62845
62846
62847
62848
62849
62850
62851
62852
62853
62854
62855
62856
62857
62858
62859
62860
62861
62862
62863
62864
62865
62866
62867
62868

No.cores x
cross-sec.
mm
20G1,5
25G1,5
3G2,08
4G2,08
5G2,08
7G0,5
9G2,08
10G2,08
12G2,08
15G2,08
18G2,08
19G2,08
25G2,08
3G3,31
4G3,31
5G3,31
6G3,31
7G3,31
9G3,31
12G3,31
15G3,31
19G3,31
20G3,31
25G3,31
3G6
4G6
5G6
7G6

AWG-No. Outer
approx.
mm
16
17,5
16
19,6
14
9,8
14
10,7
14
11,6
14
12,5
14
15,0
14
16,3
14
16,9
14
18,3
14
19,5
14
19,7
14
23,3
12
11,4
12
12,5
12
14,4
12
14,6
12
15,5
12
17,7
12
19,7
12
21,0
12
23,1
12
25,0
12
27,1
10
14,1
10
15,5
10
16,8
10
18,2

Cop.
weight
kg/km
340,0
434,0
112,0
121,0
150,0
200,0
240,0
264,0
350,0
409,0
471,0
505,0
652,0
137,0
169,0
201,0
236,0
262,0
334,0
434,0
531,0
720,0
764,0
914,0
240,0
305,0
399,0
505,0

Weight
approx.
kg/km
524,0
704,0
179,0
222,0
266,0
326,0
435,0
427,0
592,0
635,0
780,0
799,0
1042,0
237,0
314,0
386,0
425,0
496,0
740,0
887,0
903,0
1123,0
1490,0
1865,0
389,0
549,0
610,0
851,0

Continuation

N 35
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRAYCONTROL 500-C flexible, oil-resistant, screened, EMC-preferred


type, open installation TC-ER, PLTC-ER, ITC-ER, NFPA 79 Edition 2007


Part no.
62869
62870
62871
62872

No.cores x
cross-sec.
mm
9G6
12G6
19G6
4G10

AWG-No. Outer
approx.
mm
10
20,9
10
24,4
10
27,5
8
18,7

Cop.
weight
kg/km
704,0
940,0
1210,0
535,0

Weight
approx.
kg/km
1132,0
1523,0
1952,0
852,0

Part no.
62873
62874
62875

No.cores x
cross-sec.
mm
4G16
4G25
4G35

AWG-No. Outer
approx.
mm
6
23,3
4
28,6
2
33,2

Cop.
weight
kg/km
740,0
1140,0
1576,0

Weight
approx.
kg/km
1202,0
1971,0
2887,0

Dimensions and specifications may be changed without prior notice. (RN01)

Marking
Marking rings
Cable marker
Indian pen

You can nd marking in our catalogue Cable Accessories.

N 36
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRAYCONTROL 600-C flexible, oil-resistant, screened, EMC-preferred


type, open installation (TC-ER), NFPA 79 Edition 2007


Technical data

Cable structure

Properties

PVCpower cable according to UL 1277


Temperature range
UL / CSA TC -40 C to +90 C
UL / AWM -40 C to +90 C
Nominal voltage
TC 600 V
AWM 1000 V
WTTC 1000 V
Test voltage
3000 V
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
approx. 6x cable
Insulation resistance
Min. 20 MOhm x km
Radiation resistance
Up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper conductor, fine wire stranded


with AWG dimensions
Special PVC core insulation with transparent
nylon skin
Black cores with continuous white
numbering
Green-yellow earth core in the outer layer,
3 cores and more
Cores stranded in layers with optimal
lay-lengths
Separating foil
Braided screening of tinned copper wires,
coverage approx. 85%
Separator
Special PVC outer jacket
Sheath colour -black (RAL 9005)
With lenght marking in feet

Self-extinguishing and flame retardant


materialin accordance with CSA FT4
The materials used in manufacture are free
of silicone, cadmium and substances that
impair paint wetting
UV-resistant
Tests
UL:
TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER
(AWG 18 - AWG 12), UL 1277, UL Type WTTC,
UL Type MTW
NFPA 79 2007, Oil Res I (Oil Res II also
available), 90 C dry / 75 C wet
CSA:
c (UL) CIC-TC FT4,
CSA AWM I/II A/B FT4


Note

G = with green-yellow earth core


X =without earth core(OZ)
Advantages
TC-ER, Tray Cable Exposed Run
Simple installation
Outstanding flexibility


Application
USANFPA 79, Edition 2007 compliant, screened, flexible power cable to 600 V (WTTC 1000 V), for all tool and plant construction machinery,
suitable for installation in dry, damp and wet environments, outdoors and in pipes. For underground installation and for open, unprotected
installtion from the cable tray to the machine and industrial plants.
EMC = Electromagnetic compatibillity. To optimise EMC characteristics, we recommend a large contact area for the copper braiding around
the entire circumference on both ends.
= The productconforms to the EC Low-Voltage Directive 2006/95/EG.


Part no.
63049
63050
63051
63052
63053
63054
63055
62997
63056
63057
63058
63059
63060
63061
63062
63063

No.cores x
cross-sec.
mm
3G1
4G1
5G1
7G1
12G1
18G1
25G1
3G1,32
4G1,32
5G1,32
7G1,32
12G1,32
18G1,32
25G1,32
3G2,08
4G2,08

AWG-No. Outer
approx.
mm
18
8,2
18
8,8
18
9,4
18
10,1
18
12,9
18
15,7
18
17,7
16
8,9
16
9,6
16
10,3
16
11,3
16
15,1
16
17,3
16
19,6
14
9,8
14
10,7

Cop.
weight
kg/km
31,0
52,0
62,0
83,0
143,0
207,0
284,0
57,0
72,0
84,0
124,0
199,0
290,0
384,0
85,0
115,0

Weight
approx.
kg/km
118,0
136,0
149,0
193,0
328,0
431,0
569,0
144,0
172,0
186,0
243,0
421,0
510,0
704,0
178,0
220,0


Part no.
63064
63065
63066
63067
63068
63069
63070
63071
63072
63073
63074
63075
63076
63077
63078

No.cores x
cross-sec.
mm
5G2,08
7G2,08
12G2,08
18G2,08
25G2,08
4G3,31
5G3,31
7G3,31
4G6
5G6
7G6
4G10
4G16
4G25
4G35

AWG-No. Outer
approx.
mm
14
11,6
14
12,5
14
16,9
14
19,5
14
23,3
12
12,5
12
14,4
12
15,5
10
15,5
10
16,8
10
18,2
8
18,7
6
23,3
4
28,6
2
33,2

Cop.
weight
kg/km
139,0
185,0
309,0
448,0
632,0
179,0
223,0
298,0
256,0
312,0
430,0
426,0
657,0
1026,0
1412,0

Weight
approx.
kg/km
264,0
325,0
591,0
780,0
1041,0
313,0
384,0
492,0
547,0
608,0
850,0
851,0
1197,0
1970,0
2874,0

Dimensions and specifications may be changed without prior notice. (RN01)

N 37
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRAYCONTROL 300 flexible, oil-resistant, NFPA 79 Edition 2007




Technical data

Cable structure

Properties

Flexible PVC data and control cable


Temperature range
-25 Cto +105 C
Nominal voltage 300 V
Test voltage2000 V
Minimum bending radius
Flexing 4x cable

Tinned copper conductor, fine wire


stranded, with AWG measures
Special PVC core insulation (AWG 22 - AWG
16 with transparent nylon skin)
Core identification according to
international colour code
Cores stranded in layers with optimal
lay-lengths
Separator
Special PVC outer sheath
Sheath colour - grey (RAL 7001)
With length marking in feet

Self-extinguishing and flame retardant in


accordance with CSA FT4
The materials used in manufacture are free
of silicone, cadmium and substances that
impair paint wetting
Tests
UL(AWG 22 - AWG 16): PLTC-ER,
ITC-ER, Type CM, NFPA 79 2007,
OIL RES I & II, Class I Div. 2, NEC Art.
501, 725, 760 & 800, AWM 2464
UL (AWG 24 - AWG 28):CM, AWM
2464, rated OIL RES I & II,
NEC Art. 725, 760 & 800, NFPA 79 2007
CSA: CSA CMG FT4, AWM I/II A/B


Note

Advantages
highly-flexible easy to install
Oil-resistant to OIL RES I & II
Available on request
PUR or TPE outer sheath
Sheath colour to suit customer
requirements


Application
HELUKABEL TRAYCONTROL 300 is a multi-core PVC data and control cable. Cross-sections with PLTC-ER and ITC-ER approval suitable for open,
unprotected installation in cable trays to the machine; their outstanding oil resistance (OIL RES I & II) makes them ideally suited as connecting
and joining cables and also for control, signal and measuring systems in industrial plants. The flexible cable structure facilitates installation
inside and outside of machines and switch cabinets.
Applications: tool machines, control panels, control and instrumentation technology, production automation, cable ducts, renewable energies.
= The product conforms to the EG Low-Voltage Directive 2006/95/EG



Part no.
62625
62626
62627
62628
62629
62630
62631
62632
62633
62634
62635
62636
62637
62638
62639
62640
62641
62642
62643
62644
62645
62646
62647
62648
62649
62650
62651
62652
62653
62654

No.cores x
cross-sec.
mm
2x0,08
3x0,08
4x0,08
6x0,08
8x0,08
10x0,08
15x0,08
20x0,08
25x0,08
30x0,08
40x0,08
50x0,08
2x0,14
3x0,14
4x0,14
6x0,14
8x0,14
10x0,14
15x0,14
20x0,14
25x0,14
30x0,14
40x0,14
50x0,14
2x0,25
3x0,25
4x0,25
6x0,25
8x0,25
10x0,25

AWG-No. Outer
approx.
mm
28
3,7
28
4,0
28
4,2
28
4,7
28
5,0
28
5,6
28
6,2
28
6,8
28
7,8
28
8,2
28
8,9
28
9,9
26
4,0
26
4,1
26
4,3
26
5,0
26
5,3
26
6,0
26
6,6
26
7,5
26
8,3
26
8,6
26
9,4
26
10,6
24
4,2
24
4,4
24
4,7
24
5,4
24
5,7
24
6,4

Cop.
weight
kg/km
1,6
2,0
3,0
5,0
6,0
8,0
12,0
15,0
19,0
23,0
31,0
38,0
3,0
4,0
5,0
8,0
11,0
13,0
20,0
27,0
34,0
40,0
54,0
67,0
5,0
7,0
10,0
14,0
19,0
24,0

Weight
approx.
kg/km
12,0
18,0
21,0
27,0
30,0
30,0
43,0
54,0
63,0
73,0
89,0
109,0
18,0
21,0
24,0
30,0
34,0
42,0
52,0
67,0
80,0
92,0
116,0
145,0
19,0
22,0
27,0
33,0
42,0
49,0


Part no.
62655
62656
62657
62658
62659
62660
62661
62662
62663
62664
62665
62666
62667
62668
62669
62670
62671
62672
62673
62674
62675
62676
62677
62678
62679
62680
62681
62682
62683
62684

No.cores x
cross-sec.
mm
15x0,25
20x0,25
25x0,25
30x0,25
40x0,25
50x0,25
2x0,34
3x0,34
4x0,34
6x0,34
8x0,34
10x0,34
15x0,34
20x0,34
25x0,34
30x0,34
40x0,34
50x0,34
2x0,75
3x0,75
4x0,75
6x0,75
8x0,75
10x0,75
15x0,75
20x0,75
25x0,75
30x0,75
40x0,75
50x0,75

AWG-No. Outer
approx.
mm
24
7,2
24
8,2
24
9,1
24
9,4
24
11,0
24
12,2
22
4,6
22
4,8
22
5,1
22
5,8
22
6,2
22
7,3
22
8,3
22
9,1
22
10,5
22
10,9
22
12,1
22
13,5
20
5,7
20
6,0
20
6,5
20
7,8
20
8,4
20
9,6
20
11,4
20
12,7
20
14,1
20
14,7
20
16,9
20
18,9

Cop.
weight
kg/km
36,0
48,0
60,0
72,0
96,0
120,0
7,0
10,0
13,0
20,0
26,0
33,0
49,0
65,0
82,0
98,0
131,0
163,0
14,0
22,0
29,0
43,0
58,0
72,0
108,0
144,0
180,0
216,0
288,0
360,0

Weight
approx.
kg/km
69,0
86,0
103,0
131,0
173,0
219,0
22,0
28,0
32,0
46,0
54,0
66,0
90,0
115,0
141,0
176,0
234,0
293,0
57,0
60,0
73,0
97,0
133,0
143,0
177,0
261,0
353,0
419,0
562,0
699,0

Continuation

N 38
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRAYCONTROL 300 flexible, oil-resistant, NFPA 79 Edition 2007




Part no.
62685
62686
62687
62688
62700
62689
62702
62690
62691
62692
62693
62694

No.cores x
cross-sec.
mm
2x1
3x1
4x1
6x1
6x1
8x1
8x1
10x1
15x1
20x1
25x1
30x1

AWG-No. Outer
approx.
mm
18
6,2
18
6,5
18
7,3
18
8,5
16
9,3
18
9,1
16
10,6
18
11,1
18
12,6
18
13,9
18
16,6
18
16,7

Cop.
weight
kg/km
19,0
29,0
38,0
58,0
86,0
77,0
115,0
96,0
144,0
192,0
240,0
288,0

Weight
approx.
kg/km
61,0
64,0
77,0
101,0
162,0
142,0
243,0
195,0
247,0
328,0
407,0
539,0


Part no.
62695
62696
62697
62698
62699
62703
62704
62705
62706
62707
62708
62709

No.cores x
cross-sec.
mm
40x1
50x1
2x1,5
3x1,5
4x1,5
10x1,5
15x1,5
20x1,5
25x1,5
30x1,5
40x1,5
50x1,5

AWG-No. Outer
approx.
mm
18
18,5
18
20,8
16
6,7
16
7,4
16
8,0
16
12,2
16
13,9
16
15,3
16
17,7
16
18,4
16
20,5
16
23,1

Cop.
weight
kg/km
384,0
480,0
28,0
43,0
58,0
144,0
216,0
288,0
360,0
432,0
576,0
720,0

Weight
approx.
kg/km
717,0
894,0
83,0
91,0
109,0
267,0
364,0
493,0
608,0
729,0
967,0
1214,0

Dimensions and specifications may be changed without prior notice. (RN02)

Core end sleeves and cable lugs


Core end sleeves
Solderless terminals
Tubular cable lugs
Compression joints

You can nd core end sleeves and cable lugs in our catalogue Cable Accessories.

N 39
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRAYCONTROL 300-C flexible, oil-resistant, screened, EMC-preferred


type, NFPA 79 Edition 2007


Technical data

Cable structure

Properties

Flexible screened PVC data and control


cable 
Temperature range
-25 Cto +105 C
Nominal voltage 300 V
Test voltage 2000 V
Minimum bending radius
Flexing 6x cable
Coupling resistance
max. 250 Ohm/km

Tinned copper conductor, fine wire


stranded, with AWG measures
Special PVC core insulation
(AWG 22 - AWG 16 with transparent nylon
skin)
Core identification according to
international colour code
Cores stranded in layers with optimal
lay-lengths
1. Screening with special aluminium foil
2. Screening with braid of tinned copper
wires, optimal coverage, approx. 85%
Separator
Special PVC outer sheath
Sheath colour - grey (RAL 7001)
With length marking in feet

Self-extinguishing and flame retardant in


accordance with CSA FT4
The materials used in manufacture are free
of silicone, cadmium and substances that
impair paint wetting
Tests
UL (AWG 22 - AWG 16): PLTC-ER,
ITC-ER, Type CM, NFPA 79 2007,
OIL RES I & II, Class I Div. 2, NEC Art.
501, 725, 760 & 800, AWM 2464
UL (AWG 24 - AWG 28): CM, AWM
2464, rated OIL RES I & II,
NEC Art. 725, 760 & 800, NFPA 79 2007
CSA: CSA CMG FT4, AWM I/II A/B


Note

Advantages
Highly-flexible, easy to install
Oil-resistant to OIL RES I & II
Available on request
PUR or TPE outer sheath
Sheath colour to suit customer
requirement


Application
HELUKABEL TRAYCONTROL 300 is a screened,multi-core PVC data and control cable. Cross-sections with PLTC-ER and ITC-ER approval suitable
for open, unprotected installation in cable trays to the machine; their outstanding oil resistance (OIL RES I & II) makes them ideally suited as
connecting and joining cables and also for control, signal and measuring systems in industrial plants. The flexible cable structure facilitates
installation inside and outside of machines and switch cabinets. The double-screening with aluminium foil (100%coverage) andcopper braid
(approx. 85% coverage) guarantee superior EMC protection. 
Applications: tool machines, control panels, measuring devices, production automation, cable ducts, renewable energies. 
EMC = Electromagnetic compatibility.
To optimise EMC characteristics, we recommend a large contact area for the copper braiding around the entire circumference on both
ends.
= The product conforms to the EG Low-Voltage Directive 2006/95/EG



Part no.
62710
62711
62712
62713
62714
62715
62716
62717
62718
62719
62720
62721
62722
62723
62724
62725
62726
62727
62728
62729
62730
62731
62732
62733
62734
62735
62736
62737

No.cores x
cross-sec.
mm
2x0,08
3x0,08
4x0,08
6x0,08
8x0,08
10x0,08
15x0,08
20x0,08
25x0,08
30x0,08
40x0,08
50x0,08
2x0,14
3x0,14
4x0,14
6x0,14
8x0,14
10x0,14
15x0,14
20x0,14
25x0,14
30x0,14
40x0,14
50x0,14
2x0,25
3x0,25
4x0,25
6x0,25

AWG-No. Outer
approx.
mm
28
4,4
28
4,6
28
4,9
28
5,4
28
5,7
28
6,3
28
6,9
28
7,5
28
8,5
28
8,8
28
9,6
28
11,3
26
4,6
26
4,8
26
5,0
26
5,6
26
5,9
26
6,6
26
7,3
26
8,1
26
9,0
26
9,3
26
10,2
26
11,9
24
4,9
24
5,1
24
5,3
24
6,0

Cop.
weight
kg/km
6,0
7,0
9,0
12,0
15,0
18,0
24,0
30,0
37,0
43,0
54,0
67,0
9,0
10,0
12,0
16,0
19,0
24,0
31,0
40,0
49,0
57,0
72,0
88,0
15,0
16,0
19,0
27,0

Weight
approx.
kg/km
16,0
22,0
27,0
34,0
37,0
43,0
52,0
67,0
79,0
88,0
112,0
131,0
24,0
27,0
31,0
39,0
43,0
51,0
66,0
79,0
92,0
110,0
136,0
165,0
30,0
33,0
37,0
48,0


Part no.
62738
62739
62740
62741
62742
62743
62744
62745
62746
62747
62748
62749
62750
62751
62752
62753
62754
62755
62756
62757
62758
62759
62760
62761
62762
62763
62764
62765

No.cores x
cross-sec.
mm
8x0,25
10x0,25
15x0,25
20x0,25
25x0,25
30x0,25
40x0,25
50x0,25
2x0,34
3x0,34
4x0,34
6x0,34
8x0,34
10x0,34
15x0,34
20x0,34
25x0,34
30x0,34
40x0,34
50x0,34
2x0,75
3x0,75
4x0,75
6x0,75
8x0,75
10x0,75
15x0,75
20x0,75

AWG-No. Outer
approx.
mm
24
6,3
24
7,1
24
8,2
24
8,9
24
9,8
24
10,1
24
11,2
24
13,0
22
5,3
22
5,5
22
5,8
22
6,5
22
6,9
22
8,1
22
9,0
22
9,7
22
11,4
22
11,8
22
12,9
22
14,3
20
6,4
20
6,7
20
7,2
20
8,6
20
9,1
20
10,4
20
12,3
20
13,6

Cop.
weight
kg/km
31,0
39,0
51,0
64,0
77,0
92,0
118,0
148,0
19,0
22,0
27,0
34,0
45,0
69,0
77,0
92,0
121,0
139,0
177,0
215,0
28,0
34,0
40,0
54,0
70,0
83,0
119,0
130,0

Weight
approx.
kg/km
57,0
67,0
85,0
106,0
128,0
155,0
206,0
249,0
34,0
40,0
46,0
60,0
72,0
85,0
115,0
140,0
176,0
210,0
273,0
331,0
73,0
77,0
91,0
118,0
158,0
173,0
218,0
298,0

Continuation

N 40
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRAYCONTROL 300-C flexible, oil-resistant, screened, EMC-preferred


type, NFPA 79 Edition 2007


Part no.
62766
62767
62768
62769
62770
62771
62772
62773
62774
62775
62776
62777
62778
62779

No.cores x
cross-sec.
mm
25x0,75
30x0,75
40x0,75
50x0,75
2x1
3x1
4x1
6x1
8x1
10x1
15x1
20x1
25x1
30x1

AWG-No. Outer
approx.
mm
20
15,0
20
15,5
20
17,7
20
19,7
18
6,9
18
7,2
18
8,0
18
9,2
18
9,8
18
12,0
18
13,5
18
14,7
18
16,9
18
17,6

Cop.
weight
kg/km
186,0
224,0
288,0
337,0
37,0
49,0
58,0
82,0
100,0
124,0
180,0
234,0
277,0
323,0

Weight
approx.
kg/km
401,0
477,0
623,0
752,0
80,0
86,0
101,0
130,0
168,0
226,0
295,0
386,0
462,0
590,0


Part no.
62780
62781
62782
62783
62784
62785
62786
62787
62788
62789
62790
62791
62792
62793

No.cores x
cross-sec.
mm
40x1
50x1
2x1,5
3x1,5
4x1,5
6x1,5
8x1,5
10x1,5
15x1,5
20x1,5
25x1,5
30x1,5
40x1,5
50x1,5

AWG-No. Outer
approx.
mm
18
19,4
18
21,6
16
7,4
16
8,1
16
8,7
16
10,0
16
11,2
16
13,1
16
14,7
16
16,2
16
18,6
16
19,3
16
21,5
16
24,3

Cop.
weight
kg/km
416,0
508,0
51,0
63,0
76,0
104,0
134,0
168,0
234,0
301,0
367,0
428,0
550,0
669,0

Weight
approx.
kg/km
773,0
958,0
110,0
116,0
139,0
195,0
283,0
316,0
410,0
551,0
675,0
794,0
1033,0
1274,0

Dimensions and specifications may be changed without prior notice. (RN02)

Tools
Cable shears
Box spanners
Strippers
Crimping tools
Pliers
Skinning knife

You can nd tools in our catalogue Cable Accessories.

N 41
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRAYCONTROL 300 TP stranded pair, flexible, oil-resistant,


NFPA 79 Edition 2007


Technical data

Cable structure

Properties

Flexible PVC data and control cable


Temperature range
-25 C to +105 C
Nominal voltage 300 V
Test voltage 2000 V
Minimum bending radius
Flexing 6x cable

Tinned copper conductor, fine wire


stranded, with AWG measures
Special PVC core insulation
(AWG 22 - AWG 18 with transparent nylon
skin)
Pairidentification according to international
colour code
Cores stranded inpairs with optimal
lay-length
Pairs stranded in layers with optimal
lay-length
Separator
Special PVC outer sheath
Sheath colour - grey (RAL 7001)
With length marking in feet

Self-extinguishing and flame retardant in


accordance with CSA FT4
The materials used in manufacture are free
of silicone, cadmium and substances that
impair paint wetting
Tests
UL (AWG 22 - AWG 18): PLTC-ER,
ITC-ER, Type CM, NFPA 79 2007,
OIL RES I & II, Class I Div. 2, NEC Art.
501, 725, 760 & 800, AWM 2464
UL (AWG 24 - AWG 26): CM, AWM
2464, rated OIL RES I & II,
NEC Art. 725, 760 & 800, NFPA 79 2007
CSA: CSA CMG FT4, AWM I/II A/B


Note

Advantages
Highly-flexible, easy to install
Oil-resistant to OIL RES I & II
Available on request
PUR or TPE outer sheath
Sheath colour to suit customer
requirement


Application
HELUKABEL TRAYCONTROL 300 TP is a stranded pair data and control cable. Cross-sections with PLTC-ER and ITC-ER approval for open,
unprotected installation in cable trays to the machine; their outstanding oil resistance (OIL RES I & II) makes them ideally suited as connecting
and joining cables and also for control, signal and measuring systems in industrial plants. The flexible cable structure facilitates installation
inside and outside of machines and switch cabinets.
Applications: tool machines, control panels, measuring devices, production automation, cable ducts, renewable energies.
= The product conforms to the EG Low-Voltage Directive 2006/95/EG



Part no. No.pairs x
no.cores x
cross-sec.
mm
62794
1x2x0,14
62795
2x2x0,14
62796
3x2x0,14
62797
4x2x0,14
62798
5x2x0,14
62799
6x2x0,14
62800
7x2x0,14
61928
8x2x0,14
61929
10x2x0,14
61930
12x2x0,14
61931
14x2x0,14
61932
15x2x0,14
61933
16x2x0,14
61934
18x2x0,14
61935
20x2x0,14
61936
22x2x0,14
61937
24x2x0,14
61938
25x2x0,14
61939
1x2x0,25
61940
2x2x0,25
61941
3x2x0,25
61942
4x2x0,25
61943
5x2x0,25
61944
6x2x0,25
61945
7x2x0,25
61946
8x2x0,25
61947
10x2x0,25
61948
12x2x0,25
61949
14x2x0,25
61950
15x2x0,25

AWG-No.

26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
24
24
24
24
24
24
24
24
24
26
24
24

Outer
Cop.
approx. mm weight
kg/km
3,6
5,1
5,3
5,8
6,2
6,8
6,9
7,3
7,4
9,1
9,8
10,6
10,7
11,1
11,9
12,4
13,1
13,4
3,9
5,9
6,2
6,5
7,2
8,1
8,2
8,9
10,5
11,0
11,6
12,0

3,0
5,0
8,0
11,0
14,0
16,0
19,0
22,0
27,0
33,0
38,0
41,0
43,0
49,0
54,0
59,0
65,0
67,0
5,0
10,0
15,0
20,0
25,0
29,0
34,0
39,0
49,0
59,0
69,0
74,0

Weight
approx.
kg/km
20,0
24,0
30,0
38,0
44,0
51,0
57,0
64,0
76,0
93,0
103,0
109,0
112,0
119,0
130,0
150,0
169,0
178,0
32,0
36,0
48,0
56,0
71,0
80,0
89,0
98,0
111,0
135,0
160,0
171,0


Part no. No.pairs x
no.cores x
cross-sec.
mm
61951
16x2x0,25
61952
18x2x0,25
61953
20x2x0,25
61954
22x2x0,25
61955
24x2x0,25
61956
25x2x0,25
61957
1x2x0,34
61958
2x2x0,34
61959
3x2x0,34
61960
4x2x0,34
61961
5x2x0,34
61962
6x2x0,34
61963
7x2x0,34
61964
8x2x0,34
61965
10x2x0,34
61966
12x2x0,34
61967
14x2x0,34
61968
15x2x0,34
61969
16x2x0,34
61970
18x2x0,34
61971
20x2x0,34
61972
22x2x0,34
61973
24x2x0,34
61974
25x2x0,34
61975
1x2x0,75
61976
2x2x0,75
61977
3x2x0,75
61978
4x2x0,75
61979
5x2x0,75
61980
6x2x0,75

AWG-No.

24
24
24
24
24
24
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
20
20
20
20
20
20

Outer
Cop.
approx. mm weight
kg/km
12,1
13,5
14,4
15,3
16,1
16,7
4,2
6,4
6,8
79,0
8,2
8,9
9,0
9,9
11,7
12,4
13,0
13,2
13,3
14,2
15,1
15,8
17,0
17,5
5,2
8,8
9,3
10,2
11,3
12,5

79,0
89,0
98,0
109,0
118,0
124,0
7,0
13,0
20,0
7,6
33,0
39,0
46,0
52,0
65,0
78,0
92,0
98,0
105,0
118,0
131,0
144,0
157,0
163,0
11,0
22,0
32,0
43,0
54,0
65,0

Weight
approx.
kg/km
185,0
209,0
230,0
248,0
279,0
292,0
38,0
44,0
60,0
26,0
92,0
119,0
128,0
139,0
171,0
194,0
222,0
231,0
240,0
264,0
291,0
300,0
359,0
381,0
60,0
80,0
94,0
104,0
130,0
151,0

Continuation

N 42
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRAYCONTROL 300 TP stranded pair, flexible, oil-resistant,


NFPA 79 Edition 2007

Part no. No.pairs x


no.cores x
cross-sec.
mm
61981
7x2x0,75
61982
8x2x0,75
61983
10x2x0,75
61984
12x2x0,75
61985
14x2x0,75
61986
15x2x0,75
61987
16x2x0,75
61988
18x2x0,75
61989
20x2x0,75

AWG-No.

20
20
20
20
20
20
20
20
20

Outer
Cop.
approx. mm weight
kg/km
12,6
15,9
16,4
17,2
18,1
18,5
18,6
19,9
21,1

75,0
86,0
108,0
129,0
151,0
161,0
172,0
194,0
215,0

Weight
approx.
kg/km
174,0
262,0
298,0
302,0
327,0
370,0
402,0
480,0
551,0


Part no. No.pairs x
no.cores x
cross-sec.
mm
61990
22x2x0,75
61991
24x2x0,75
61992
25x2x0,75
61993
1x2x1
61994
1x2x1
61995
3x2x1
61996
6x2x1
61997
9x2x1
61998
15x2x1

AWG-No.

20
20
20
18
18
18
18
18
18

Outer
Cop.
approx. mm weight
kg/km
21,8
23,5
24,3
5,6
9,6
10,6
13,7
16,4
20,4

237,0
258,0
269,0
18,0
36,0
54,0
107,0
162,0
271,0

Weight
approx.
kg/km
621,0
703,0
721,0
61,0
77,0
103,0
216,0
328,0
542,0

Dimensions and specifications may be changed without prior notice. (RN02)

Signal and power circular connectors


Series A, B, C, D, F and S
Tools
Accessories
Online congurator
Pre-assembled cables

You can nd signal and power circular connectors in our catalogue Cable Accessories.

N 43
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRAYCONTROL 300-C TP stranded pair, flexible, screened,


oil-resistant, EMC-preferred type, NFPA 79 Edition 2007


Technical data

Cable structure

Properties

Flexible screened PVC data and control


cable
Temperature range
-25 C to +105 C
Nominal voltage 300 V
Test voltage 2000 V
Minimum bending radius
Flexing 6x cable
Coupling resistance
max. 250 Ohm/km

Tinned copper conductor, fine wire


stranded, with AWG measures
Special PVC core insulation
(AWG 22 - AWG 18 with transparent nylon
skin)
Pairidentification according to international
colour code
Cores stranded inpairs with optimal
lay-length
Pairs stranded in layers with optimal
lay-length
1. Screening with special aluminium foil
2. Screening with braid of tinned copper
wires, optimal coverage, approx. 85%
Separator
Special PVC outer sheath
Sheath colour - grey (RAL 7001)
With length marking in feet

Self-extinguishing and flame retardant in


accordance with CSA FT4
The materials used in manufacture are free
of silicone, cadmium and substances that
impair paint wetting
Tests
UL (AWG 22 - AWG 18): PLTC-ER,
ITC-ER, CM, NFPA 79 2007,
OIL RES I & II, Class I Div. 2, NEC Art.
501, 725, 760 & 800, AWM 2464
UL (AWG 24 - AWG 26): CM, AWM
2464, rated OIL RES I & II,
NEC Art. 725, 760 & 800, NFPA 79 2007
CSA: CSA CMG FT4, AWM I/II A/B


Note

Advantages
Highly-flexible, easy to install
Oil-resistant to OIL RES I & II
Available on request
PUR or TPE outer sheath
Sheath colour to suit customer
requirement

Application
HELUKABEL TRAYCONTROL 300 is a screened, stranded pairdata and control cable. Cross-sections with PLTC-ER and ITC-ER approval suitable
for open, unprotected installation in cable trays to the machine; their outstanding oil resistance (OIL RES I & II) makes them ideally suited as
connecting and joining cables and also for control, signal and measuring systems in industrial plants. The flexible cable structure facilitates
installation inside and outside of machines and switch cabinets. The double-screening with aluminium foil (100% coverage) and copper braid
(approx. 85% coverage) guarantee superior EMC protection.
Applications: tool machines, control panels, measuring devices, production automation, cable ducts, renewable energies. 
EMC = Electromagnetic compatibility.
To optimise EMC characteristics, we recommend a large contact area for the copper braiding around the entire circumference on both
ends.
= The product conforms to the EG Low-Voltage Directive 2006/95/EG



Part no. No.pairs x
no.cores x
cross-sec.
mm
61999
1x2x0,14
59760
2x2x0,14
59761
3x2x0,14
59762
4x2x0,14
59763
5x2x0,14
59764
6x2x0,14
59765
7x2x0,14
59766
8x2x0,14
59767
10x2x0,14
59768
12x2x0,14
59769
14x2x0,14
59770
15x2x0,14
59771
16x2x0,14
59772
18x2x0,14
59773
20x2x0,14
59774
22x2x0,14
59775
24x2x0,14
59776
25x2x0,14
59777
1x2x0,25
59778
2x2x0,25
59779
3x2x0,25
59780
4x2x0,25
59781
5x2x0,25
59782
6x2x0,25
59783
7x2x0,25
59784
8x2x0,25

AWG-No.

26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
24
24
24
26
24
24
24
24

Outer
Cop.
approx. mm weight
kg/km
4,0
5,6
5,8
6,3
6,7
7,3
7,4
7,8
9,1
9,8
10,5
11,1
11,2
11,8
12,4
13,1
13,6
15,1
4,6
6,6
6,9
7,5
8,0
8,8
8,9
9,7

16,0
20,0
24,0
27,0
31,0
50,0
52,0
54,0
60,0
67,0
75,0
77,0
80,0
84,0
98,0
104,0
112,0
114,0
16,0
27,0
32,0
37,0
55,0
66,0
60,0
74,0

Weight
approx.
kg/km
32,0
39,0
47,0
55,0
68,0
86,0
92,0
97,0
111,0
141,0
150,0
154,0
155,0
170,0
183,0
207,0
228,0
239,0
46,0
53,0
65,0
79,0
98,0
114,0
121,0
129,0


Part no. No.pairs x
no.cores x
cross-sec.
mm
59785
10x2x0,25
59786
12x2x0,25
59787
14x2x0,25
59788
15x2x0,25
59789
16x2x0,25
59790
18x2x0,25
59791
20x2x0,25
59792
22x2x0,25
59793
24x2x0,25
59794
25x2x0,25
59795
1x2x0,34
59796
2x2x0,34
59797
3x2x0,34
59798
4x2x0,34
59799
5x2x0,34
59800
6x2x0,34
59801
7x2x0,34
59802
8x2x0,34
59803
10x2x0,34
59804
12x2x0,34
59805
14x2x0,34
59806
15x2x0,34
59807
16x2x0,34
59808
18x2x0,34
59809
20x2x0,34
59810
22x2x0,34

AWG-No.

24
24
24
24
24
24
24
24
24
24
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22

Outer
Cop.
approx. mm weight
kg/km
11,4
11,8
12,6
12,8
12,9
13,8
14,4
15,3
16,4
16,7
4,9
7,1
7,7
8,4
9,0
9,6
9,7
10,7
12,7
13,2
13,9
14,1
14,2
15,3
15,9
16,8

109,0
116,0
121,0
132,0
142,0
147,0
161,0
171,0
230,0
231,0
17,0
37,0
45,0
54,0
63,0
73,0
79,0
88,0
107,0
122,0
138,0
154,0
161,0
198,0
211,0
218,0

Weight
approx.
kg/km
152,0
189,0
213,0
225,0
227,0
238,0
270,0
300,0
321,0
340,0
58,0
65,0
79,0
88,0
110,0
126,0
140,0
148,0
184,0
210,0
241,0
245,0
251,0
275,0
300,0
320,0

Continuation

N 44
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TRAYCONTROL 300-C TP stranded pair, flexible, screened,


oil-resistant, EMC-preferred type, NFPA 79 Edition 2007

Part no. No.pairs x


no.cores x
cross-sec.
mm
59811
24x2x0,34
59812
25x2x0,34
59813
1x2x0,75
59814
2x2x0,75
59815
3x2x0,75
59816
4x2x0,75
59817
5x2x0,75
59818
6x2x0,75
59819
7x2x0,75
59820
8x2x0,75
59821
10x2x0,75
59822
12x2x0,75
59823
14x2x0,75

AWG-No.

22
22
20
20
20
20
20
20
20
20
20
20
20

Outer
Cop.
approx. mm weight
kg/km
18,0
18,3
5,9
9,4
10,5
11,5
12,6
13,3
13,4
16,8
17,5
18,0
19,1

230,0
239,0
26,0
56,0
72,0
92,0
107,0
122,0
132,0
144,0
180,0
202,0
221,0

Weight
approx.
kg/km
371,0
402,0
70,0
89,0
102,0
119,0
140,0
162,0
198,0
272,0
307,0
318,0
342,0

Part no. No.pairs x


no.cores x
cross-sec.
mm
59824
15x2x0,75
59825
16x2x0,75
59826
18x2x0,75
59827
20x2x0,75
59828
22x2x0,75
59829
24x2x0,75
59830
25x2x0,75
59831
1x2x1
59832
2x2x1
59833
3x2x1
59834
6x2x1
59835
9x2x1
59836
15x2x1

AWG-No.

20
20
20
20
20
20
20
18
18
18
18
18
18

Outer
Cop.
approx. mm weight
kg/km
19,4
19,5
20,5
21,5
22,6
24,4
24,9
6,3
10,2
11,5
14,6
17,2
21,3

232,0
257,0
282,0
307,0
322,0
342,0
361,0
28,0
57,0
75,0
139,0
212,0
358,0

Weight
approx.
kg/km
381,0
417,0
494,0
570,0
643,0
724,0
740,0
104,0
121,0
150,0
328,0
490,0
811,0

Dimensions and specifications may be changed without prior notice. (RN02)

Cable Glands
Cable glands for standard applications
Plastic Glands
Cable Glands of Brass
Accessories
Cable glands for special application conditions
for electromagnetic compatibility EMC
for rugged applications and special chemical resistance
for high temperature use
for explosive areas
for special mounting conditions
for special pressure conditions

You can nd cable glands in our catalogue Cable Accessories.

N 45
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-602-PUR 80C, 600V, two approvals control cable, meter marking




Technical data

Cable structure

Properties

Control cable of special-PUR to UL CSA AWM


I/II A/B Style20939 (jacket insulation) and
CSA
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage according to
UL + CSA 600 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Insulation resistance
min 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire stranded to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special PVC core insulation TI3, to
DINVDE0281 part1 and UL-Style10012
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Full-polyurethane
outer jacket grey (RAL 7001)
with meter marking, change-over in 2011


Resistant to mineral oils, synthetic oils,


water based coolants, UV-radiation,
oxygene, ozon and hydrolysis. Conditionally
resistant to microbes.
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
JZ-602-C-PUR, see page N 51

Application
UL and CSA approved flexible control cable rated at 600 V, primarily designed for exporters to the US or Canadian market. Used in machine
tools, control systems, connection between control panels and machines, assembly lines and other industrial equipment. Suitable for
installation in dry, moist, wet and outdoor environment and moderate flexing applications.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
12471
12472
12473
12474
12475
12476
12477
12478
12479
12480
12481
12482
12483
12484
12485
12486
12487
12488
12489
12490
12491
12492
12493
12494

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
8G0,5
9G0,5
12G0,5
18G0,5
25G0,5
34G0,5
41G0,5
2x1
3G1
4G1
5G1
7G1
8G1
9G1
12G1
18G1
25G1
34G1
41G1

AWG-No. Outer
approx.
mm
20
5,8
20
6,2
20
6,6
20
7,2
20
8,4
20
9,5
20
10,3
20
10,8
20
12,8
20
15,4
20
17,6
20
19,7
18
6,2
18
6,6
18
7,2
18
7,8
18
9,1
18
9,9
18
11,0
18
11,7
18
14,0
18
17,0
18
19,2
18
21,0

Cop.
weight
kg/km
9,6
14,0
19,0
24,0
34,0
38,4
43,2
58,0
86,0
120,0
163,0
197,0
19,2
27,0
38,4
48,0
67,0
76,8
86,4
115,2
173,0
240,0
326,0
394,0

Weight
approx.
kg/km
52,0
64,0
72,0
88,0
130,0
145,0
180,0
196,0
260,0
368,0
502,0
594,0
57,0
68,0
79,0
97,0
141,0
152,0
190,0
211,0
284,0
394,0
521,0
609,0


Part no.
12495
12496
12497
12498
12499
12500
12501
12502
12503
12504
12505
12506
12507
12508
12509
12510
12511
12512
12513
12514
12515
12516
12517

No.cores x
cross-sec.
mm
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
9G1,5
12G1,5
18G1,5
25G1,5
34G1,5
41G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
9G2,5
12G2,5
18G2,5
19G2,5
25G2,5
3G4
4G4

AWG-No. Outer
approx.
mm
16
6,8
16
7,4
16
8,0
16
8,6
16
10,5
16
12,7
16
13,3
16
15,7
16
18,8
16
22,0
16
23,6
14
8,1
14
8,6
14
10,0
14
10,8
14
13,0
14
15,5
14
16,6
14
19,5
14
19,5
14
23,8
12
11,1
12
12,4

Cop.
weight
kg/km
28,8
44,0
58,0
72,0
101,0
129,7
173,0
260,0
360,0
490,0
590,0
48,0
72,0
96,0
120,0
168,0
216,0
288,0
432,0
456,0
600,0
115,0
154,0

Weight
approx.
kg/km
75,0
96,0
117,0
140,0
186,0
244,0
319,0
451,0
625,0
850,0
1041,0
115,0
143,0
185,0
221,0
293,0
429,0
563,0
854,0
914,0
1188,0
232,0
298,0

Continuation

N 46
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-602-PUR 80C, 600V, two approvals control cable, meter marking




Part no.
12518
12519
12520
12521
12522
12523
12524
12525
12526

No.cores x
cross-sec.
mm
5G4
7G4
3G6
4G6
5G6
7G6
3G10
4G10
5G10

AWG-No. Outer
approx.
mm
12
13,7
12
16,2
10
12,8
10
14,1
10
15,7
10
19,2
8
16,8
8
18,3
8
20,1

Cop.
weight
kg/km
192,0
269,0
173,0
231,0
288,0
403,0
288,0
384,0
480,0

Weight
approx.
kg/km
358,0
460,0
360,0
402,0
484,0
630,0
535,0
653,0
786,0


Part no.
12527
12528
12529
12530
12531
12532
12533
12534
12535
12536
12537
12538
12539
12540
12541
12542
12543

No.cores x
cross-sec.
mm
7G10
2x16
3G16
4G16
5G16
7G16
3G25
4G25
5G25
7G25
3G35
4G35
5G35
4G50
4G70
4G95
4G120

AWG-No. Outer
approx.
mm
8
22,4
6
19,2
6
20,5
6
23,0
6
25,5
6
28,2
4
25,0
4
28,1
4
30,9
4
35,5
2
28,6
2
31,7
2
35,5
1
35,8
2/0
41,6
3/0
46,0
4/0
52,8

Cop.
weight
kg/km
672,0
307,0
461,0
615,0
768,0
1075,0
720,0
960,0
1200,0
1680,0
1008,0
1344,0
1680,0
1920,0
2688,0
3648,0
4608,0

Weight
approx.
kg/km
1100,0
640,0
810,0
1045,0
1260,0
1760,0
1180,0
1507,0
1858,0
2830,0
1590,0
2123,0
2612,0
3058,0
4254,0
5762,0
7280,0

Dimensions and specifications may be changed without prior notice. (RN01)

Conduits
Corrugated tubes
for standard applications
for lager sizes
scissile corrugated tubes
conduit glands
High exible conduits
plastic conduits with spiral spring
metal conduits
conduits glands
Conduit for heavy mechanical duty
metal conduits with plastic sheat
plastic conduits
conduits glands for metal conduits

You can nd conduits in our catalogue Cable Accessories.

N 47
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-602-PUR DC/AC 80C, 600V, two approvals control cable,


meter marking


Technical data

Cable structure

Properties

Control cable of special-PUR to UL CSA AWM


I/II A/B Style20939 (jacket insulation) and
CSA
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage according to
UL + CSA 600 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Insulation resistance
min 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire stranded to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special PVC core insulation TI3, to
DINVDE0281 part1 and UL-Style10012
Blue (DC) or red (AC) cores with continuous
white numbering
Green-yellow earth core
Cores stranded in layers with optimal
lay-length
Full-polyurethane
outer jacket grey (RAL 7001)
with meter marking, change-over in 2011


Resistant to mineral oils, synthetic oils,


water based coolants, UV-radiation,
oxygene, ozon and hydrolysis. Conditionally
resistant to microbes.
High abrasion resistance
Tear and cut resistant
The materials used in manufacturing are
cadmium-free and do not contain no
silicone any silicone and free from
substances harmful to the wetting
properties of lacquers


Note

G = with green-yellow earth core;


DC = blue cores;
AC = red cores;
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
For use on conveyor belts, tooling machines, conveyor system, production lines and automotive production plants. Also for medium
mechanical stress in flexible applications with free movement and without tensile stress. UL and CSA approved control cables espacially for
U.S. and Canadian markets.
=The product conforms to the EC Low Voltage Directive 2006/95/EG


JZ-602 PUR DC (blue core)


Part no.
12805
12806
12807
12808
12809
12810
12811
12812
12813
12814
12815
12816
12817
12818
12819
12820
12821
12822
12823
12824
12825

No.cores x
cross-sec.
mm
3G1
4G1
5G1
7G1
12G1
18G1
25G1
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5

AWG-No. Outer
approx.
mm
18
6,6
18
7,2
18
7,8
18
9,1
18
11,7
18
14,0
18
17,0
16
7,4
16
8,0
16
8,6
16
10,5
16
13,3
16
15,7
16
18,8
14
8,6
14
10,0
14
10,8
14
13,0
14
16,6
14
19,5
14
23,8

Cop.
weight
kg/km
27,0
38,0
48,0
67,0
115,0
173,0
240,0
44,0
58,0
72,0
101,0
173,0
260,0
360,0
72,0
96,0
120,0
168,0
288,0
432,0
600,0

Weight
approx.
kg/km
68,0
79,0
97,0
141,0
211,0
284,0
394,0
96,0
117,0
140,0
186,0
319,0
451,0
625,0
143,0
185,0
221,0
293,0
563,0
854,0
1188,0

JZ-602 PUR AC (red core)


Part no.
12826
12827
12828
12829
12830
12831
12832
12833
12834
12835
12836
12837
12838
12839
12840
12841
12842
12843
12844
12845
12846

No.cores x
cross-sec.
mm
3G1
4G1
5G1
7G1
12G1
18G1
25G1
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5

AWG-No. Outer
approx.
mm
18
6,6
18
7,2
18
7,8
18
9,1
18
11,7
18
14,0
18
17,0
16
7,4
16
8,0
16
8,6
16
10,5
16
13,3
16
15,7
16
18,8
14
8,6
14
10,0
14
10,8
14
13,0
14
16,6
14
19,5
14
23,8

Cop.
weight
kg/km
27,0
38,0
48,0
67,0
115,0
173,0
240,0
44,0
58,0
72,0
101,0
173,0
260,0
360,0
72,0
96,0
120,0
168,0
288,0
432,0
600,0

Weight
approx.
kg/km
68,0
79,0
97,0
141,0
211,0
284,0
394,0
96,0
117,0
140,0
186,0
319,0
451,0
625,0
143,0
185,0
221,0
293,0
563,0
854,0
1188,0

Dimensions and specifications may be changed without prior notice. (RN01)

N 48
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-600 PUR tear and coolant resistant, 0,6/1kV, meter marking




Technical data

Cable structure

Properties

Special PUR control cables Adapted to


DINVDE0276 part627, DINVDE0281
part13, with insulation thickness for
1kV type and UL-Std.758 Style20234
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Power rating
as per DIN VDE 0298
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, as per


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special PVC core insulation TI2, to
DINVDE0281 part1, class43
UL-Std.1581UL-Style10012
Black cores with white figure imprints to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Outer jacket, special full-polyurethane
adapted to DINVDE0282 part10,
appendixA, flame retardant to UL-Std.758
Colour black (RAL9005) or grey (RAL7001)
with meter marking, change-over in 2011


High abrasion resistance


High flexibility
Resistant to ultra violet rays
Wear resistant
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
JZ-600-YC-PUR, see page N 52

Application
Extremely robust, control cable resistant to mineral oils and to coolant emulsions. In tool machinery, conveyor belts and production lines,
for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium
mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside.
Interesting for the export-oriented machinery plants.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.cores x


Jacket cross-sec.
colour mm
black
28240
2x0,5
28241
3G0,5
28242
4G0,5
28243
5G0,5
28244
7G0,5
28245
12G0,5
28246
18G0,5
28247
25G0,5
28248
2x0,75
28249
3G0,75
28250
4G0,75
28251
5G0,75
28252
7G0,75
28253
12G0,75
28254
18G0,75
28255
25G0,75
28256
2x1
28257
3G1
28258
4G1
28259
5G1
28260
7G1
28261
12G1
28262
18G1
28263
25G1
28264
2x1,5
28265
3G1,5
28266
4G1,5
28267
5G1,5
28268
7G1,5
28269
12G1,5
28270
18G1,5
28271
25G1,5

AWG-No.

20
20
20
20
20
20
20
20
19
19
19
19
19
19
19
19
18
18
18
18
18
18
18
18
16
16
16
16
16
16
16
16

Outer
Cop.
approx. mm weight
kg/km
6,9
7,3
7,9
8,5
9,9
12,2
14,4
17,2
7,3
7,7
8,3
9,1
10,7
13,1
15,6
18,9
7,9
8,3
9,1
9,9
11,7
14,5
17,3
21,1
8,7
9,2
10,0
11,0
13,3
16,6
19,7
23,9

9,6
14,4
19,0
24,0
33,6
58,0
86,0
120,0
14,4
21,6
29,0
36,0
50,0
86,0
130,0
180,0
19,2
29,0
38,4
48,0
67,0
115,0
173,0
240,0
29,0
43,0
58,0
72,0
101,0
173,0
259,0
360,0

Weight
approx.
kg/km
60,0
70,0
104,0
120,0
141,0
208,0
289,0
342,0
70,0
78,0
134,0
149,0
201,0
269,0
378,0
498,0
86,0
100,0
107,0
130,0
174,0
290,0
405,0
570,0
97,0
118,0
141,0
181,0
234,0
370,0
520,0
730,0


Part no. No.cores x
Jacket cross-sec.
colour mm
grey
28305
2x0,5
28306
3G0,5
28307
4G0,5
28308
5G0,5
28309
7G0,5
28310
12G0,5
28311
18G0,5
28312
25G0,5
28313
2x0,75
28314
3G0,75
28315
4G0,75
28316
5G0,75
28317
7G0,75
28318
12G0,75
28319
18G0,75
28320
25G0,75
28321
2x1
28322
3G1
28323
4G1
28324
5G1
28325
7G1
28326
12G1
28327
18G1
28328
25G1
28329
2x1,5
28330
3G1,5
28331
4G1,5
28332
5G1,5
28333
7G1,5
28334
12G1,5
28335
18G1,5
28336
25G1,5

AWG-No.

20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16

Outer
Cop.
approx. mm weight
kg/km
6,9
7,3
7,9
8,5
9,9
12,2
14,4
17,2
7,3
7,7
8,3
9,1
10,7
13,1
15,6
18,9
7,9
8,3
9,1
9,9
11,7
14,5
17,3
21,1
8,7
9,2
10,0
11,0
13,3
16,6
19,7
23,9

9,6
14,4
19,0
24,0
33,6
58,0
86,0
120,0
14,4
21,6
29,0
36,0
50,0
86,0
130,0
180,0
19,2
29,0
38,4
48,0
67,0
115,0
173,0
240,0
29,0
43,0
58,0
72,0
101,0
173,0
259,0
360,0

Weight
approx.
kg/km
60,0
70,0
104,0
120,0
141,0
208,0
289,0
342,0
70,0
78,0
134,0
149,0
201,0
269,0
378,0
498,0
86,0
100,0
107,0
130,0
174,0
290,0
405,0
570,0
97,0
118,0
141,0
181,0
234,0
370,0
520,0
730,0

Continuation

N 49
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-600 PUR tear and coolant resistant, 0,6/1kV, meter marking



Part no. No.cores x
Jacket cross-sec.
colour mm
black
28272
2x2,5
28273
3G2,5
28274
4G2,5
28275
5G2,5
28276
7G2,5
28277
12G2,5
28278
18G2,5
28279
25G2,5
28280
2x4
28281
3G4
28282
4G4
28283
5G4
28284
7G4
28285
12G4
28286
3G6
28287
4G6
28288
5G6
28289
7G6
28290
3G10
28291
4G10
28292
5G10
28293
7G10
28294
3G16
28295
4G16
28296
5G16
28297
7G16
28298
3G25
28299
4G25
28300
5G25
28301
7G25

AWG-No.

14
14
14
14
14
14
14
14
12
12
12
12
12
12
10
10
10
10
8
8
8
8
6
6
6
6
4
4
4
4

Outer
Cop.
approx. mm weight
kg/km
9,5
10,0
11,1
12,4
15,0
18,4
22,0
26,9
11,4
12,3
13,8
15,3
16,8
22,9
14,1
15,6
17,3
19,3
16,5
18,4
20,5
22,5
19,6
21,7
24,2
25,7
24,0
26,9
29,3
32,6

48,0
72,0
96,0
120,0
168,0
288,0
432,0
600,0
77,0
115,0
154,0
192,0
269,0
461,0
173,0
230,0
288,0
403,0
288,0
384,0
480,0
672,0
461,0
614,0
768,0
1075,0
720,0
960,0
1200,0
1680,0

Weight
approx.
kg/km
170,0
181,0
203,0
251,0
330,0
553,0
795,0
1110,0
190,0
235,0
310,0
410,0
540,0
860,0
370,0
430,0
650,0
860,0
660,0
790,0
960,0
1300,0
709,0
1114,0
1620,0
1900,0
1450,0
1600,0
2050,0
2900,0


Part no. No.cores x
Jacket cross-sec.
colour mm
grey
28337
2x2,5
28338
3G2,5
28339
4G2,5
28340
5G2,5
28341
7G2,5
28342
12G2,5
28343
18G2,5
28344
25G2,5
28345
2x4
28346
3G4
28347
4G4
28348
5G4
28349
7G4
28350
12G4
28351
3G6
28352
4G6
28353
5G6
28354
7G6
28355
3G10
28356
4G10
28357
5G10
28358
7G10
28359
3G16
28360
4G16
28361
5G16
28362
7G16
28363
3G25
28364
4G25
28365
5G25
28366
7G25

AWG-No.

14
14
14
14
14
14
14
14
12
12
12
12
12
12
10
10
10
10
8
8
8
8
6
6
6
6
4
4
4
4

Outer
Cop.
approx. mm weight
kg/km
9,5
10,0
11,1
12,4
15,0
18,4
22,0
26,9
11,4
12,3
13,8
15,3
16,8
22,9
14,1
15,6
17,3
19,3
16,5
18,4
20,5
22,5
19,6
21,7
24,2
25,8
24,0
26,9
29,3
32,6

48,0
72,0
96,0
120,0
168,0
288,0
432,0
600,0
77,0
115,0
154,0
192,0
269,0
461,0
173,0
230,0
288,0
403,0
288,0
384,0
480,0
672,0
461,0
614,0
768,0
1075,0
720,0
960,0
1200,0
1680,0

Weight
approx.
kg/km
170,0
181,0
203,0
251,0
330,0
553,0
795,0
1110,0
190,0
235,0
310,0
410,0
540,0
860,0
370,0
430,0
650,0
860,0
660,0
790,0
960,0
1300,0
709,0
1114,0
1620,0
1900,0
1450,0
1600,0
2050,0
2900,0

Dimensions and specifications may be changed without prior notice. (RN01)

N 50
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-602-C-PUR screened two approvals control cable, 80C, 600V,


EMC-preferred type, meter marking


Technical data

Cable structure

Properties

Special PUR-insulated to UL CSA AWM I/II


A/B Style20939 (jacket insulation) and CSA
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage
according to UL+CSA 600 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, fine wire stranded to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special PVC core insulation TI3, to
DINVDE0281 part1 and UL-Style10012
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
PVC-insulated inner sheath YM5 to
DINVDE0207 part5
Braided screen of tinned Cu wires approx.
85% coverage
Full-polyurethane
outer jacket grey (RAL 7001)
with meter marking, change-over in 2011


Resistant to mineral oils, synthetic oils and


refrigerants, UV-radiation, osygene, ozon
and hydrolysis. Conditionally resistant to
microbes.
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
JZ-602 PUR, see page N 46

Application
UL and CSA approved flexible control cables up to 600 V, for all machinery in tooling and plant construction, suitable for installation in dry,
moist, wet and outdoor environments for medium mechanical loads. Designed for the export-orientated machinery manufacturer, specifically
for USA and Canada.
EMC = Electromagnetic compatibility
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
12550
12551
12552
12553
12554
12555
12556
12557
12558
12559
12560
12561
12562
12563
12564
12565
12566
12567
12568
12569
12570
12571
12572
12573
12574
12575
12576
12577
12578
12579
12580
12581
12582
12583
12584
12585
12586
12587

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
9G0,5
12G0,5
18G0,5
25G0,5
34G0,5
41G0,5
2x1
3G1
4G1
5G1
7G1
9G1
12G1
18G1
25G1
34G1
41G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
9G1,5
12G1,5
18G1,5
25G1,5
34G1,5
41G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5

AWG-No. Outer
approx.
mm
20
7,7
20
8,0
20
8,6
20
9,2
20
10,5
20
12,3
20
13,0
20
15,6
20
18,2
20
20,1
20
22,4
18
8,1
18
8,4
18
9,1
18
10,0
18
11,3
18
13,3
18
13,8
18
16,2
18
19,5
18
22,5
18
24,2
16
8,7
16
9,2
16
10,0
16
10,8
16
12,9
16
14,8
16
15,6
16
18,3
16
22,5
16
25,1
16
27,3
14
10,3
14
10,8
14
11,8
14
13,2
14
15,6

Cop.
weight
kg/km
41,0
45,0
54,0
66,0
79,0
94,0
137,0
156,0
250,0
316,0
348,0
54,0
64,0
76,0
89,0
114,0
144,0
186,0
284,0
387,0
500,0
578,0
64,0
82,0
99,0
123,0
148,0
187,0
274,0
386,0
531,0
671,0
840,0
110,0
148,0
169,0
220,0
284,0

Weight
approx.
kg/km
93,0
124,0
133,0
153,0
191,0
243,0
322,0
374,0
436,0
560,0
663,0
107,0
130,0
155,0
181,0
209,0
321,0
341,0
473,0
650,0
781,0
892,0
136,0
165,0
192,0
224,0
273,0
340,0
461,0
674,0
950,0
1203,0
1588,0
173,0
220,0
270,0
329,0
428,0


Part no.
12588
12589
12590
12591
12592
12593
12594
12595
12596
12597
12598
12599
12600
12601
12602
12603
12604
12605
12606
12607
12608
12609
12610
12611
12612
12613
12614
12615
12616
12617
12618
12619
12620

No.cores x
cross-sec.
mm
9G2,5
12G2,5
18G2,5
25G2,5
2x4
3G4
4G4
5G4
7G4
2x6
3G6
4G6
5G6
7G6
3G10
4G10
5G10
7G10
3G16
4G16
5G16
7G16
3G25
4G25
5G25
7G25
3G35
4G35
5G35
4G50
4G70
4G95
4G120

AWG-No. Outer
approx.
mm
14
18,1
14
19,2
14
23,0
14
28,3
12
12,5
12
13,1
12
14,5
12
15,8
12
19,0
10
14,2
10
15,2
10
16,6
10
18,4
10
22,2
8
19,1
8
21,1
8
23,7
8
26,5
6
24,2
6
27,2
6
30,6
6
33,6
4
30,2
4
33,3
4
36,8
4
40,6
2
33,8
2
37,7
2
41,5
1
40,5
2/0
46,1
3/0
50,7
4/0
57,0

Cop.
weight
kg/km
349,0
470,0
572,0
740,0
124,0
178,0
234,0
284,0
321,0
176,0
245,0
316,0
442,0
530,0
367,0
549,0
604,0
820,0
653,0
807,0
940,0
1345,0
920,0
1169,0
1420,0
1921,0
1250,0
1680,0
2020,0
2370,0
3257,0
4060,0
5231,0

Weight
approx.
kg/km
580,0
761,0
1140,0
1551,0
209,0
310,0
456,0
532,0
737,0
318,0
411,0
572,0
732,0
961,0
741,0
988,0
1202,0
1743,0
1088,0
1662,0
2021,0
2720,0
1947,0
2591,0
3197,0
4530,0
2701,0
3277,0
4530,0
3370,0
4630,0
6114,0
7417,0

Dimensions and specifications may be changed without prior notice. (RN01)

N 51
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-600-YC-PUR tear and coolant resistant, 0,6/1kV, Cu-screened,


EMC-preferred type, meter marking


Technical data

Cable structure

Properties

Special PUR control cables Adapted to


DINVDE0276 part627, DINVDE0281
part13, with insulation thickness for 1kV
type and UL-Std.758 Style20234
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Power rating
as per DIN VDE 0298
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, fine wire conductors, as per


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special PVC core insulation TI2, to
DINVDE0281 part1, class43 UL-Std.1581
UL-Style10012
Black cores with white figure imprints to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Oil resistant PVC inner jacket, TM5 to
DINVDE0281 part1 and class43 gem.
UL-Std.1581
Tinned copper braided screening, approx.
85% coverage
Outer jacket, special full-polyurethane
adapted to DINVDE0282 part10,
appendixA, flame retardant to UL-Std.758
Colour black (RAL9005) or grey (RAL7001)
with meter marking, change-over in 2011





High abrasion resistance


High flexibility
Resistant to ultra violet rays
Wear resistant
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
JZ-600 PUR, see page N 49

Application
Extremely robust, control cable resistant to mineral oils and to coolant emulsions. In tool machinery, conveyor belts and production lines,
for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium
mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside.
Interesting for the export-oriented machinery plants.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
Jacket cross-sec.
colour mm
black
28370
2x0,5
28371
3G0,5
28372
4G0,5
28373
5G0,5
28374
7G0,5
28375
12G0,5
28376
18G0,5
28377
25G0,5
28378
2x0,75
28379
3G0,75
28380
4G0,75
28381
5G0,75
28382
7G0,75
28383
12G0,75
28384
18G0,75
28385
25G0,75
28386
2x1
28387
3G1
28388
4G1
28389
5G1
28390
7G1
28391
12G1
28392
18G1
28393
25G1
28394
2x1,5
28395
3G1,5
28396
4G1,5

AWG-No.

20
20
20
20
20
20
20
20
19
19
19
19
19
19
19
19
18
18
18
18
18
18
18
18
16
16
16

Outer
Cop.
approx. mm weight
kg/km
9,0
9,3
9,9
10,6
12,2
14,7
17,3
20,6
9,4
9,8
10,4
11,1
13,0
15,8
17,9
22,8
9,9
10,3
11,1
12,2
14,5
17,4
20,7
24,8
10,7
11,2
12,3

41,0
45,0
54,0
66,0
79,0
137,0
156,0
250,0
46,0
57,0
63,0
76,0
100,0
175,0
240,0
306,0
54,0
64,0
76,0
89,0
114,0
186,0
284,0
387,0
64,0
82,0
99,0

Weight
approx.
kg/km
131,0
154,0
176,0
204,0
237,0
323,0
431,0
507,0
143,0
158,0
193,0
231,0
337,0
424,0
568,0
741,0
158,0
169,0
207,0
244,0
292,0
472,0
634,0
861,0
166,0
192,0
246,0


Part no. No.cores x
Jacket cross-sec.
colour mm
grey
28430
2x0,5
28431
3G0,5
28432
4G0,5
28433
5G0,5
28434
7G0,5
28435
12G0,5
28436
18G0,5
28437
25G0,5
28438
2x0,75
28439
3G0,75
28440
4G0,75
28441
5G0,75
28442
7G0,75
28443
12G0,75
28444
18G0,75
28445
25G0,75
28446
2x1
28447
3G1
28448
4G1
28449
5G1
28450
7G1
28451
12G1
28452
18G1
28453
25G1
28454
2x1,5
28455
3G1,5
28456
4G1,5

AWG-No.

20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
16
16
16

Outer
Cop.
approx. mm weight
kg/km
9,0
9,3
9,9
10,6
12,2
14,7
17,3
20,6
9,4
9,8
10,4
11,1
13,0
15,8
17,9
22,8
9,9
10,3
11,1
12,2
14,5
17,4
20,7
24,8
10,7
11,2
12,3

30,0
39,0
52,0
61,0
75,0
130,0
170,0
230,0
39,0
57,0
68,0
79,0
96,0
169,0
224,0
292,0
51,8
67,0
78,0
94,0
122,0
201,0
275,0
364,0
68,0
84,0
104,0

Weight
approx.
kg/km
131,0
154,0
176,0
204,0
237,0
323,0
431,0
507,0
143,0
158,0
193,0
231,0
337,0
424,0
568,0
741,0
158,0
169,0
207,0
244,0
292,0
472,0
634,0
861,0
166,0
192,0
246,0

Continuation

N 52
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-600-YC-PUR tear and coolant resistant, 0,6/1kV, Cu-screened,


EMC-preferred type, meter marking

Part no. No.cores x


Jacket cross-sec.
colour mm
black
28397
5G1,5
28398
7G1,5
28399
12G1,5
28400
18G1,5
28401
25G1,5
28402
2x2,5
28403
3G2,5
28404
4G2,5
28405
5G2,5
28406
7G2,5
28407
12G2,5
28408
18G2,5
28409
25G2,5
28410
2x4
28411
3G4
28412
4G4
28413
5G4
28414
7G4
28415
3G6
28416
4G6
28417
5G6
28418
3G10
28419
4G10
28420
5G10
28421
3G16
28422
4G16
28423
5G16

AWG-No.

16
16
16
16
16
14
14
14
14
14
14
14
14
12
12
12
12
12
10
10
10
8
8
8
6
6
6

Outer
Cop.
approx. mm weight
kg/km
13,3
16,0
19,6
23,4
28,2
11,8
12,3
13,4
14,9
17,9
21,9
26,1
31,9
14,3
15,1
16,7
18,6
20,0
17,0
18,7
20,7
19,6
21,9
24,1
23,5
26,4
28,8

123,0
148,0
274,0
386,0
531,0
110,0
148,0
169,0
220,0
284,0
470,0
572,0
740,0
124,0
178,0
234,0
284,0
321,0
245,0
316,0
442,0
367,0
549,0
604,0
653,0
807,0
940,0

Weight
approx.
kg/km
294,0
392,0
599,0
817,0
1261,0
280,0
301,0
352,0
433,0
569,0
864,0
1365,0
1997,0
310,0
396,0
531,0
704,0
932,0
633,0
742,0
1117,0
1131,0
1357,0
1646,0
1397,0
1880,0
2721,0


Part no. No.cores x
Jacket cross-sec.
colour mm
grey
28457
5G1,5
28458
7G1,5
28459
12G1,5
28460
18G1,5
28461
25G1,5
28462
2x2,5
28463
3G2,5
28464
4G2,5
28465
5G2,5
28466
7G2,5
28467
12G2,5
28468
18G2,5
28469
25G2,5
28470
2x4
28471
3G4
28472
4G4
28473
5G4
28474
7G4
28475
3G6
28476
4G6
28477
5G6
28478
3G10
28479
4G10
28480
5G10
28481
3G16
28482
4G16
28483
5G16

AWG-No.

16
16
16
16
16
14
14
14
14
14
14
14
14
12
12
12
12
12
10
10
10
8
8
8
6
6
6

Outer
Cop.
approx. mm weight
kg/km
13,3
16,0
19,6
23,4
28,2
11,8
12,3
13,4
14,9
17,9
21,9
26,1
31,9
14,3
15,1
16,7
18,6
20,0
17,0
18,7
20,7
19,6
21,9
24,1
23,5
26,4
28,8

123,0
180,0
284,0
390,0
521,0
99,0
124,0
170,0
202,0
268,0
423,0
572,0
740,0
156,0
191,0
236,0
303,0
394,0
251,0
319,0
421,0
371,0
576,0
620,0
540,0
807,0
1394,0

Weight
approx.
kg/km
294,0
392,0
599,0
817,0
1261,0
280,0
301,0
352,0
433,0
569,0
864,0
1365,0
1997,0
310,0
396,0
531,0
704,0
932,0
633,0
742,0
1117,0
1131,0
1357,0
1646,0
1397,0
1880,0
2721,0

Dimensions and specifications may be changed without prior notice. (RN01)

N 53
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MEGAFLEX 500 halogen-free, flame retardant, oil-resistant,


UV-resistant, flexible, meter marking


Technical data

Cable structure

Properties

Halogen-free flexible control cable,


core-structure adapted to DIN VDE 0281
part14, to UL-Style 20939, UL-Std. 758
Temperature range
flexing -30 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Minimum bending radius
flexing approx. 10x cable
fixed installation approx. 4x cable
Flexible
Alternate bending test according to DIN
VDE 0281-2

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of halogen-free special
polymer
Black cores with white continuous
numbering to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layer with optimal
lay-length
Outer sheath, halogen-free special polymer
Outer jacket colour grey (RAL7001)
with meter marking, change-over in 2011
The materials used in manufacture are
cadmium-free and contain no silicone and
are free from substances harmful to the
wetting properties of lacquers

LS0H = Low Smoke Zero Halogen-free.


Halogen-free
Highly flame-retardant
Resistant to oils and greases
Resistant to UV and weathering
Hydrolysis resistant
Flexible, abrasion- and wear-resistant
Ozone-resistant
Recycleable
Tests
Flame test to VDE0482-332-3/ BS4066
part3/
DIN EN60332-3/ IEC60332-3-24 (previously
DINVDE0472 part804 test methodC)
Self-extinguishing and flame retardant
according to DINVDE0482-332-1-2, DIN
EN/IEC60332-1 (previously DINVDE0472
part804 test methodB)
Corrosiveness of combustion gases
according to NFX10-702
Halogen-free according to DINVDE0482
part267/ EN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to DINVDE0482
part1034-1+2, DINEN61034-1+2/
IEC61034-1+2, BS7622 part1+2 (previously
DINVDE0472 part816)
Oil-resistant to DIN EN 60811-2-1
Hydrolysis-resistant to DINEN61234-1
Ozone-resistant to DIN EN 60811-2-1 /
DIN VDE 0281-2


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
Also available as a 0,6/1 kV cable under
consideration of economical minimum
quantities. MEGAFLEX 600
screened analogue type:
MEGAFLEX 500-C, see page N 56


Application
For fixed installation or flexible application, with free movements without forcing which do not constantly recur and without tensile stress,
for high mechanical strain.As a measuring and control cable primarily in machinery and plant contruction, in building and air-conditoning
systems, in warehousing and converying systems, in ship-building and for regenerative types of energy such as in the construction of wind
power stations. Especially well-suited for use in public buildings, such as airports and train stations, where personal injuries and subsequent
damage must be prevented in the event of a fire. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
13344
13345
13346
13347
13348
13349
13350
13351

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4G0,5
4x0,5
5G0,5
5x0,5
7G0,5

Outer
Cop.
approx. mm weight
kg/km
4,8
9,6
5,1
14,4
5,1
14,4
5,7
19,0
5,7
19,0
6,2
24,0
6,2
24,0
7,4
33,6

Weight
approx.
kg/km
43,0
50,0
50,0
60,0
60,0
71,0
71,0
84,0

AWG-No.
20
20
20
20
20
20
20
20


Part no.
13352
13353
13354
13355
13356
13357
13359
13360

No.cores x
cross-sec.
mm
8G0,5
10G0,5
12G0,5
16G0,5
18G0,5
20G0,5
25G0,5
30G0,5

Outer
Cop.
approx. mm weight
kg/km
8,0
38,0
8,8
48,0
9,1
58,0
10,0
76,0
10,7
86,0
11,2
96,0
12,7
120,0
13,5
144,0

Weight
approx.
kg/km
101,0
121,0
142,0
183,0
204,0
227,0
283,0
324,0

AWG-No.
20
20
20
20
20
20
20
20

Continuation

N 54
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MEGAFLEX 500 halogen-free, flame retardant, oil-resistant,


UV-resistant, flexible, meter marking

Part no.
13361
13362
13363
13364
13365
13366
13367
13368
13369
13370
13371
13372
13373
13374
13375
13376
13377
13378
13379
13380
13381
13382
13383
13384
13385
13386
13387
13388
13389
13390
13392
13393
13394
13395
13396
13397
13398
13399
13400
13401
13402
13403
13404
13405
13406
13407
13408
13409
13410
13411
13412
13413
13414
13415
13416
13417
13418
13419
13420
13421
13422
13423
13425
13426
13427
13428
13429
13430
13431
13432
13433
13434
13435
13436

No.cores x
cross-sec.
mm
34G0,5
37G0,5
41G0,5
42G0,5
50G0,5
61G0,5
65G0,5
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
7G0,75
7x0,75
8G0,75
10G0,75
12G0,75
16G0,75
18G0,75
20G0,75
25G0,75
30G0,75
34G0,75
37G0,75
41G0,75
42G0,75
50G0,75
61G0,75
65G0,75
2x1
3G1
3x1
4G1
4x1
5G1
7G1
8G1
10G1
12G1
16G1
18G1
20G1
25G1
34G1
37G1
41G1
42G1
50G1
61G1
65G1
2x1,5
3G1,5
3x1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5
16G1,5
18G1,5
20G1,5
25G1,5
34G1,5
37G1,5
50G1,5
61G1,5
65G1,5
2x2,5
3G2,5
4G2,5
5G2,5

Outer
Cop.
approx. mm weight
kg/km
14,5
163,0
15,0
178,0
15,8
197,0
15,8
202,0
17,3
240,0
19,4
293,0
19,4
312,0
5,2
14,4
5,5
21,6
5,5
21,6
6,2
29,0
6,2
29,0
6,8
36,0
6,8
36,0
8,1
50,0
8,1
50,0
8,9
58,0
9,6
72,0
9,9
86,0
11,2
115,0
11,9
130,0
12,6
144,0
14,1
180,0
15,4
216,0
16,4
245,0
17,2
260,0
17,6
296,0
17,6
302,0
19,8
360,0
20,9
439,0
21,5
468,0
5,5
19,2
6,0
29,0
6,0
29,0
6,6
38,4
6,6
38,4
7,2
48,0
8,6
67,0
9,4
77,0
10,4
96,0
10,7
115,0
12,0
154,0
12,7
173,0
13,5
192,0
15,2
240,0
17,4
326,0
18,4
355,0
18,9
394,0
18,9
403,0
21,0
480,0
22,2
586,0
22,8
628,0
6,1
29,0
6,5
43,0
6,5
43,0
7,2
58,0
7,9
72,0
9,5
101,0
10,4
115,0
11,3
144,0
11,7
173,0
13,3
230,0
14,0
259,0
14,9
288,0
16,8
360,0
19,4
490,0
20,2
533,0
23,4
720,0
24,8
878,0
26,0
936,0
7,6
48,0
8,3
72,0
9,1
96,0
10,2
120,0

Weight
approx.
kg/km
367,0
381,0
417,0
454,0
519,0
635,0
694,0
47,0
56,0
56,0
69,0
69,0
83,0
83,0
114,0
114,0
136,0
172,0
183,0
241,0
266,0
291,0
374,0
450,0
517,0
541,0
611,0
621,0
742,0
853,0
909,0
63,0
74,0
74,0
90,0
90,0
109,0
151,0
184,0
224,0
243,0
314,0
361,0
387,0
496,0
670,0
713,0
784,0
824,0
952,0
1140,0
1201,0
70,0
94,0
94,0
112,0
141,0
191,0
224,0
282,0
311,0
392,0
450,0
497,0
630,0
842,0
897,0
1277,0
1460,0
1612,0
118,0
151,0
181,0
224,0

AWG-No.
20
20
20
20
20
20
20
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14


Part no.
13437
13438
13439
13440
13441
13442
13443
13444
13445
13446
13447
13448
13449
13450
13451
13452
13453
13454
13455
13456
13457
13458
13459
13460
13461
13462
13463
13464
13465
13466
13467
13468
13469
13470
13471
13472
13473
13474
13475
13476
13477
13478
13479
13480
13481
13482
13483
13484
13485
13486
13487
13488
13489

No.cores x
cross-sec.
mm
7G2,5
8G2,5
10G2,5
12G2,5
16G2,5
18G2,5
20G2,5
25G2,5
30G2,5
2x4
3G4
4G4
5G4
7G4
8G4
10G4
12G4
16G4
18G4
2x6
3G6
4G6
5G6
7G6
2x10
3G10
4G10
5G10
7G10
2x16
3G16
4G16
5G16
7G16
3G25
4G25
5G25
3G35
4G35
5G35
3G50
4G50
5G50
3G70
4G70
5G70
3G95
4G95
5G95
3G120
4G120
3G150
4G150

Outer
Cop.
approx. mm weight
kg/km
12,1
168,0
13,2
192,0
14,6
240,0
15,2
288,0
16,8
384,0
18,1
432,0
19,0
480,0
22,2
600,0
22,9
720,0
9,2
77,0
9,9
115,0
11,0
154,0
12,1
192,0
13,3
269,0
15,9
307,0
17,3
384,0
18,3
461,0
20,2
614,0
21,8
691,0
10,8
115,0
11,7
173,0
13,0
230,0
14,5
288,0
16,0
403,0
14,0
192,0
15,0
288,0
16,8
384,0
18,7
480,0
20,6
672,0
16,5
307,0
17,6
461,0
19,7
641,0
21,9
768,0
24,4
1075,0
22,5
720,0
25,2
960,0
27,9
1200,0
26,3
1008,0
29,2
1344,0
32,7
1680,0
31,5
1440,0
35,0
1920,0
38,7
2400,0
37,2
2016,0
42,2
2688,0
47,4
3360,0
42,1
2736,0
47,0
3648,0
52,3
4560,0
46,6
3456,0
51,4
4608,0
53,0
4320,0
59,0
5760,0

Weight
approx.
kg/km
316,0
370,0
451,0
499,0
720,0
769,0
911,0
1047,0
1280,0
199,0
247,0
299,0
369,0
463,0
601,0
698,0
790,0
1130,0
1280,0
266,0
360,0
429,0
529,0
631,0
440,0
550,0
708,0
862,0
1124,0
642,0
830,0
1060,0
1270,0
1794,0
1190,0
1594,0
2014,0
1590,0
2200,0
2693,0
2571,0
3087,0
3980,0
3207,0
4077,0
5501,0
4708,0
5590,0
6972,0
5515,0
7100,0
6279,0
7781,0

AWG-No.
14
14
14
14
14
14
14
14
14
12
12
12
12
12
12
12
12
12
12
10
10
10
10
10
8
8
8
8
8
6
6
6
6
6
4
4
4
2
2
2
1
1
1
2/0
2/0
2/0
3/0
3/0
3/0
4/0
4/0
300 kcmil
300 kcmil

Dimensions and specifications may be changed without prior notice. (RA03)

N 55
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MEGAFLEX 500-C halogen-free, flame retardant, oil-resistant,


UV-resistant, flexible, screened, EMC-preferred types, meter marking


Technical data

Cable structure

Properties

Halogen-free flexible control cable,


core-structure adapted to DINVDE0281
part14, to UL-Style 20939, UL-Std. 758
Temperature range
flexing -30 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Minimum bending radius
flexing approx. 10x cable
fixed installation approx. 4x cable
Flexible
Alternate bending test according to DIN
VDE 0281-2
Coupling resistance
max. 250 Ohm/km

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of halogen-free special
polymer
Black cores with white continuous
numbering to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layer with optimal
lay-length
Separating foil
Tinned copper braided screening, coverage
approx. 85%
Outer sheath, halogen-free special polymer
Outer jacket colour grey (RAL7001)
with meter marking, change-over in 2011
The materials used in manufacture are
cadmium-free and contain no silicone and
are free from substances harmful to the
wetting properties of lacquers

LS0H = Low Smoke Zero Halogen-free.


Halogen-free
Highly flame-retardant
Resistant to oils and greases
Resistant to UV and weathering
Flexible, abrasion- and wear-resistant
Ozone-resistant
Recycleable
Tests
Flame test to VDE0482-332-3/ BS4066
part3/
DIN EN60332-3/IEC60332-3 (previously
DINVDE0472 part804 test methodC)
Self-extinguishing and flame retardant
according to DINVDE0482-332-1-2, DIN
EN/IEC60332-1 (previously DINVDE0472
part804 test methodB)
Corrosiveness of combustion gases
according to NFX10-702
Halogen-free according to DINVDE0482
part267/ EN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to DINVDE0482
part1034-1+2, DINEN61034-1+2/
IEC61034-1+2, BS7622 part1+2 (previously
DINVDE0472 part816)
Oil-resistant to DIN 60811-2-1 
hydrolysebestndig nach DINEN61234-1
Ozone-resistant to DIN EN 60811-2-1 /
DIN VDE 0281-2


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
unscreened analogue type:
MEGAFLEX 500, see page N 54

Application
For fixed installation or flexible application, with free movements without forcing which do not constantly recur and without tensile stress,
for high mechanical strain.An interference-free transmission of signals and pulse in assured by the high degree of screening.
As a measuring and control cable primarily in machinery and plant contruction, in building and air-conditoning systems, in warehousing and
converying systems, in ship-building and for regenerative types of energy such as in the construction of wind power stations.
Especially well-suited for use in public buildings, such as airports and train stations, where personal injuries and subsequent damage must
be prevented in the event of a fire.
EMC = Electromagnetic compatibillity
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
13500
13501
13502
13504
13503
13505
13506
13507

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4x0,5
4G0,5
5G0,5
5x0,5
7G0,5

Outer
Cop.
approx. mm weight
kg/km
5,7
35,0
6,0
42,0
6,0
42,0
6,5
47,0
6,5
47,0
7,0
56,0
7,0
56,0
7,9
69,0

Weight
approx.
kg/km
46,0
56,0
56,0
62,0
62,0
75,0
75,0
98,0

AWG-No.
20
20
20
20
20
20
20
20


Part no.
13508
13509
13510
13511
13512
13514
13515

No.cores x
cross-sec.
mm
8G0,5
10G0,5
12G0,5
16G0,5
18G0,5
20G0,5
25G0,5

Outer
Cop.
approx. mm weight
kg/km
8,5
80,0
9,3
94,0
9,6
108,0
10,7
129,0
11,2
145,0
11,9
172,0
13,4
240,0

Weight
approx.
kg/km
116,0
135,0
158,0
210,0
216,0
240,0
315,0

AWG-No.
20
20
20
20
20
20
20

Continuation

N 56
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MEGAFLEX 500-C halogen-free, flame retardant, oil-resistant,


UV-resistant, flexible, screened, EMC-preferred types, meter marking

Part no.
13516
13517
13518
13519
13520
13521
13522
13523
13524
13525
13526
13527
13528
13529
13530
13531
13532
13533
13534
13535
13536
13537
13538
13539
13540
13541
13542
13543
13544
13545
13546
13547
13548
13549
13550
13552
13554
13556
13557
13558
13559
13560
13561
13562
13563
13565

No.cores x
cross-sec.
mm
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
7G0,75
7x0,75
8G0,75
10G0,75
12G0,75
16G0,75
18G0,75
20G0,75
25G0,75
2x1
3G1
3x1
4G1
4x1
5G1
7G1
8G1
10G1
12G1
16G1
18G1
20G1
25G1
2x1,5
3G1,5
3x1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5
16G1,5
18G1,5
20G1,5
25G1,5
2x2,5
3G2,5
4G2,5

Outer
Cop.
approx. mm weight
kg/km
6,1
40,0
6,4
52,0
6,4
52,0
6,9
60,0
6,9
60,0
7,4
71,0
7,4
71,0
8,6
91,0
8,6
91,0
9,4
110,0
10,2
137,0
10,4
142,0
11,6
200,0
12,4
212,0
12,9
238,0
14,8
281,0
6,4
50,0
6,7
60,0
6,7
60,0
7,3
71,0
7,3
71,0
7,8
88,0
9,1
111,0
9,9
127,0
10,8
150,0
11,2
184,0
12,3
209,0
13,2
260,0
13,8
317,0
15,8
349,0
6,6
63,0
6,9
80,0
6,9
80,0
7,5
97,0
8,4
119,0
10,0
147,0
10,7
170,0
11,8
193,0
12,1
267,0
13,6
315,0
14,6
374,0
15,3
396,0
17,9
526,0
8,3
96,0
9,0
144,0
9,8
148,0

Weight
approx.
kg/km
60,0
68,0
68,0
78,0
78,0
95,0
95,0
130,0
130,0
145,0
180,0
203,0
275,0
290,0
320,0
413,0
66,0
80,0
80,0
100,0
100,0
130,0
160,0
197,0
232,0
260,0
346,0
382,0
440,0
540,0
88,0
100,0
100,0
125,0
158,0
210,0
244,0
315,0
340,0
424,0
480,0
545,0
702,0
132,0
168,0
195,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14

Part no.
13566
13567
13568
13569
13570
13571
13572
13573
13574
13575
13576
13577
13578
13579
13580
13581
13582
13583
13584
13585
13586
13587
13588
13589
13590
13591
13592
13593
13594
13595
13596
13597

No.cores x
cross-sec.
mm
5G2,5
7G2,5
8G2,5
10G2,5
12G2,5
2x4
3G4
4G4
5G4
7G4
2x6
3G6
4G6
5G6
7G6
2x10
3G10
4G10
5G10
7G10
2x16
3G16
4G16
5G16
7G16
4G25
4x35
4G50
4G70
4G95
4G120
4G150

Outer
Cop.
approx. mm weight
kg/km
10,9
181,0
12,9
255,0
13,8
285,0
15,8
340,0
15,9
441,0
9,8
120,0
10,6
174,0
11,5
230,0
12,7
273,0
13,9
316,0
11,5
173,0
12,4
240,0
13,8
305,0
15,7
439,0
16,6
505,0
14,9
255,0
15,9
350,0
17,8
535,0
19,6
592,0
21,6
810,0
17,3
422,0
18,5
585,0
20,8
740,0
22,9
895,0
25,0
1282,0
26,2
1140,0
30,4
1576,0
34,6
2155,0
41,3
3120,0
46,2
4043,0
51,0
5069,0
59,0
5792,0

Weight
approx.
kg/km
256,0
345,0
390,0
482,0
572,0
220,0
251,0
305,0
388,0
504,0
270,0
351,0
464,0
546,0
670,0
461,0
574,0
785,0
914,0
1308,0
670,0
911,0
1105,0
1293,0
2149,0
1911,0
2542,0
3550,0
4939,0
6690,0
8453,0
9104,0

AWG-No.
14
14
17
14
14
12
12
12
12
12
10
10
10
10
10
8
8
8
8
8
6
6
6
6
6
4
2
1
2/0
3/0
4/0
300 kcmil

Dimensions and specifications may be changed without prior notice. (RA03)

N 57
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MEGAFLEX 600 halogen-free, flame retardant, oil-reistant, UV-resistant,


flexible, meter marking


Technical data

Cable structure

Properties

Halogen-free flexible control cable to


UL-Style 20234, UL-Std. 758
Temperature range
flexing -30 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4000 V
Minimum bending radius
flexing approx. 10x cable
fixed installation approx. 4x cable
Flexible
Alternate bending test according to DIN
VDE 0281-2

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of halogen-free special
polymer
Black cores with white continuous
numbering to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layer with optimal
lay-length
Outer sheath, halogen-free special polymer
Outer jacket colour black (RAL9005)
The materials used in manufacture are
cadmium-free and contain no silicone and
are free from substances harmful to the
wetting properties of lacquers
with meter marking, change-over in 2011

Halogen-free
Highly flame-retardant
Resistant to oils and greases
Resistant to UV and weathering
Hydrolysis resistant
Flexible, abrasion- and wear-resistant
Ozone-resistant
Recycleable
Tests
Flame test to VDE0482-332-3/BS 4066
part3/ DINEN 60332-3/ IEC60332-3-24
(previously DINVDE0472 part804 test
methodC)
Self-extinguishing and flame retardant
according to DINVDE0482-332-1-2, DIN
EN/IEC60332-1 (previously DINVDE0472
part804 test methodB)
Corrosiveness of combustion gases
according to NFX10-702
Halogen-free according to DINVDE0482
part267/ EN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to DINVDE0482
part1034-1+2, DINEN61034-1+2/
IEC61034-1+2, BS7622 part1+2 (previously
DINVDE0472 part816)
Oil-resistant to DIN EN 60811-2-1
Hydrolysis-resistant to DINEN61234-1
Ozone-resistant to DINEN60811-2-1 /
DINVDE0281-2

Note
G = with green-yellow earth core;
x = without green-yellow earth core.
screened analogue type:
MEGAFLEX 600-C, see page N 60

Application
For fixed installation or flexible application, with free movements without forcing which do not constantly recur and without tensile stress,
for high mechanical strain.As a measuring and control cable primarily in machinery and plant contruction, in building and air-conditoning
systems, in warehousing and converying systems, in ship-building and for regenerative types of energy such as in the construction of wind
power stations.
Especially well-suited for use in public buildings, such as airports and train stations, where personal injuries and subsequent damage must
be prevented in the event of a fire.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
13200
13202
13201
13203
13204
13205
13206
13207

No.cores x
cross-sec.
mm
2x0,5
3x0,5
3G0,5
4G0,5
4x0,5
5G0,5
5x0,5
7G0,5

Outer
Cop.
approx. mm weight
kg/km
6,4
9,6
6,8
14,4
6,8
14,4
7,6
19,0
7,6
19,0
8,2
24,0
8,2
24,0
9,8
33,6

Weight
approx.
kg/km
56,0
68,0
68,0
100,0
100,0
117,0
117,0
138,0

AWG-No.
20
20
20
20
20
20
20
20


Part no.
13208
13209
13210
13211
13212
13213
13214
13215

No.cores x
cross-sec.
mm
8G0,5
10G0,5
12G0,5
16G0,5
18G0,5
20G0,5
25G0,5
30G0,5

Outer
Cop.
approx. mm weight
kg/km
10,7
38,0
11,6
48,0
12,2
58,0
13,7
76,0
14,4
86,0
15,3
96,0
17,2
120,0
18,0
144,0

Weight
approx.
kg/km
150,0
176,0
200,0
250,0
276,0
293,0
335,0
348,0

AWG-No.
20
20
20
20
20
20
20
20

Continuation

N 58
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MEGAFLEX 600 halogen-free, flame retardant, oil-reistant, UV-resistant,


flexible, meter marking

Part no.
13216
13217
13218
13219
13220
13221
13222
13223
13224
13225
13226
13227
13228
13229
13230
13231
13232
13233
13234
13235
13236
13237
13238
13239
13241
13242
13243
13244
13245
13246
13247
13248
13249
13250
13251
13252
13253
13254
13255
13256
13257
13258
13259
13260
13261
13262
13263
13264
13265
13266
13267
13268
13269
13270
13271
13272
13273
13274
13275
13276
13277
13278
13279
13280

No.cores x
cross-sec.
mm
34G0,5
37G0,5
41G0,5
42G0,5
50G0,5
61G0,5
65G0,5
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
7G0,75
7x0,75
8G0,75
10G0,75
12G0,75
16G0,75
18G0,75
20G0,75
25G0,75
30G0,75
34G0,75
37G0,75
41G0,75
42G0,75
50G0,75
61G0,75
65G0,75
2x1
3G1
3x1
4G1
4x1
5G1
7G1
8G1
10G1
12G1
16G1
18G1
20G1
25G1
34G1
37G1
41G1
42G1
50G1
61G1
65G1
2x1,5
3G1,5
3x1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5
16G1,5
18G1,5
20G1,5

Outer
Cop.
approx. mm weight
kg/km
19,8
163,0
15,0
178,0
21,3
197,0
21,2
202,0
23,4
240,0
26,0
293,0
26,8
312,0
6,8
14,4
7,2
21,6
7,2
21,6
8,0
29,0
8,0
29,0
8,8
36,0
8,8
36,0
10,7
50,0
10,7
50,0
11,5
58,0
12,7
72,0
13,1
86,0
14,6
115,0
15,6
130,0
16,6
144,0
18,9
180,0
15,4
216,0
21,5
245,0
21,5
260,0
23,2
296,0
23,2
302,0
25,6
360,0
28,2
439,0
29,0
468,0
7,4
19,2
8,0
29,0
8,0
29,0
8,8
38,4
8,8
38,4
9,8
48,0
11,7
67,0
12,8
77,0
14,3
96,0
14,5
115,0
16,5
154,0
17,3
173,0
18,4
192,0
21,1
240,0
24,0
326,0
24,3
355,0
25,9
394,0
25,9
403,0
28,5
480,0
31,4
586,0
32,5
628,0
8,4
29,0
9,1
43,0
9,1
43,0
9,9
58,0
11,0
72,0
13,3
101,0
14,5
115,0
16,1
144,0
16,6
173,0
18,5
230,0
19,7
259,0
20,9
288,0

Weight
approx.
kg/km
520,0
561,0
590,0
595,0
715,0
840,0
880,0
66,0
74,0
74,0
126,0
126,0
140,0
140,0
190,0
190,0
212,0
238,0
257,0
304,0
362,0
394,0
486,0
450,0
638,0
696,0
750,0
770,0
895,0
1070,0
1110,0
80,0
96,0
96,0
100,0
100,0
130,0
170,0
230,0
270,0
290,0
360,0
405,0
450,0
570,0
750,0
790,0
890,0
900,0
1100,0
1266,0
1560,0
95,0
112,0
112,0
139,0
170,0
225,0
250,0
300,0
370,0
450,0
520,0
600,0

AWG-No.
20
20
20
20
20
20
20
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
16
16
16
16
16
16
16
16
16
16
16
16


Part no.
13281
13282
13283
13284
13285
13286
13287
13288
13289
13290
13291
13292
13293
13294
13295
13296
13297
13298
13299
13300
13301
13302
13303
13304
13305
13306
13307
13308
13309
13310
13311
13312
13313
13314
13315
13316
13317
13318
13319
13320
13321
13322
13323
13324
13325
13326
13327
13328
13329
13330
13331
13332
13333
13334
13335
13336
13337
13338
13339
13340
13341
13342
13343

No.cores x
cross-sec.
mm
25G1,5
34G1,5
37G1,5
50G1,5
61G1,5
65G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
8G2,5
10G2,5
12G2,5
16G2,5
18G2,5
20G2,5
25G2,5
30G2,5
2x4
3G4
4G4
5G4
7G4
8G4
10G4
12G4
16G4
18G4
2x6
3G6
4G6
5G6
7G6
2x10
3G10
4G10
5G10
7G10
2x16
3G16
4G16
5G16
7G16
3G25
4G25
5G25
3G35
4G35
5G35
3G50
4G50
5G50
3G70
4G70
5G70
3G95
4G95
5G95
3G120
4G120
3G150
4G150

Outer
Cop.
approx. mm weight
kg/km
23,9
360,0
27,2
490,0
29,4
533,0
32,5
720,0
35,7
878,0
36,8
936,0
9,4
48,0
9,9
72,0
11,1
96,0
12,4
120,0
15,0
168,0
16,1
192,0
17,0
240,0
18,4
288,0
19,4
384,0
22,0
432,0
32,2
480,0
26,9
600,0
28,1
720,0
11,4
77,0
12,3
115,0
13,8
154,0
15,3
192,0
16,8
269,0
20,0
307,0
21,6
384,0
22,9
461,0
23,6
614,0
24,2
691,0
13,1
115,0
14,1
173,0
15,6
230,0
17,3
288,0
19,3
403,0
15,4
192,0
16,5
288,0
18,1
384,0
20,5
480,0
22,5
672,0
18,3
307,0
19,6
461,0
21,7
641,0
24,2
768,0
25,7
1075,0
24,0
720,0
26,9
960,0
29,4
1200,0
26,2
1008,0
29,4
1344,0
32,8
1680,0
31,6
1440,0
35,5
1920,0
40,0
2400,0
36,7
2016,0
40,7
2688,0
45,7
3360,0
41,2
2736,0
46,2
3648,0
50,7
4560,0
45,9
3456,0
50,3
4608,0
52,7
4320,0
58,8
5760,0

Weight
approx.
kg/km
730,0
950,0
1094,0
1400,0
1700,0
1900,0
160,0
175,0
203,0
251,0
330,0
400,0
461,0
553,0
742,0
795,0
924,0
1110,0
1370,0
180,0
230,0
310,0
410,0
540,0
710,0
760,0
860,0
910,0
980,0
205,0
370,0
430,0
650,0
860,0
330,0
660,0
790,0
960,0
1300,0
580,0
700,0
1100,0
1600,0
1890,0
1450,0
1600,0
2050,0
1900,0
2400,0
2900,0
2700,0
3400,0
4361,0
3300,0
4400,0
5807,0
5050,0
6010,0
7752,0
5620,0
7500,0
6390,0
6840,0

AWG-No.
16
16
16
16
16
16
14
14
14
14
14
14
14
14
14
14
14
14
14
12
12
12
12
12
12
12
12
12
12
10
10
10
10
10
8
8
8
8
8
6
6
6
6
6
4
4
4
2
2
2
1
1
1
2/0
2/0
2/0
3/0
3/0
3/0
4/0
4/0
300 kcmil
300 kcmil

Dimensions and specifications may be changed without prior notice. (RA03)

N 59
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MEGAFLEX 600-C halogen-free, flame retardant, oil-resistant,


UV-resistant, flexible, meter marking


Technical data

Cable structure

Properties

Halogen-free flexible control cable to


UL-Style20234, UL-Std. 758
Temperature range
flexing -30 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4000 V
Minimum bending radius
flexing approx. 10x cable
fixed installation approx. 4x cable
Flexible
Alternate bending test according to DIN
VDE 0281-2
Coupling resistance
max. 250 Ohm/km

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of halogen-free special
polymer
Black cores with white continuous
numbering to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layer with optimal
lay-length
Separating foil
Tinned copper braided screening, coverage
approx. 85%
Outer sheath, halogen-free special polymer
Outer jacket colour black (RAL9005)
The materials used in manufacture are
cadmium-free and contain no silicone and
are free from substances harmful to the
wetting properties of lacquers
with meter marking, change-over in 2011

Halogen-free
Highly flame-retardant
Resistant to oils and greases
Resistant to UV and weathering
Flexible, abrasion- and wear-resistant
Ozone-resistant
Recycleable
Tests
Flame test to VDE0482-332-3/ BS4066
part3/ DIN EN 60332-3/IEC60332-3-24
(previously DINVDE0472 part804 test
methodC)
Self-extinguishing and flame retardant
according to DINVDE0482-332-1-2, DIN
EN/IEC60332-1 (previously DINVDE0472
part804 test methodB)
Corrosiveness of combustion gases
according to NFX10-702
Halogen-free according to DINVDE0482
part267/ EN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to DINVDE0482
part1034-1+2, DINEN61034-1+2/
IEC61034-1+2, BS7622 part1+2 (previously
DINVDE0472 part816)
Oil-resistant to DIN EN 60811-2-1
hydrolysebestndig nach DINEN61234-1
Ozone-resistant to DIN EN 60811-2-1 /
DIN VDE 0281-2


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
unscreened analogue type:
MEGAFLEX 600, see page N 58


Application
For fixed installation or flexible application, with free movements without forcing which do not constantly recur and without tensile stress,
for high mechanical strain.An interference-free transmission of signals and pulse in assured by the high degree of screening.
As a measuring and control cable primarily in machinery and plant contruction, in building and air-conditoning systems, in warehousing and
converying systems, in ship-building and for regenerative types of energy such as in the construction of wind power stations.
Especially well-suited for use in public buildings, such as airports and train stations, where personal injuries and subsequent damage must
be prevented in the event of a fire.
EMC = Electromagnetic compatibillity
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
15217
15218
15219
15220
15221
15222
15223
15224

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4G0,5
4x0,5
5G0,5
5x0,5
7G0,5

Outer
Cop.
approx. mm weight
kg/km
6,9
35,0
7,3
42,0
7,3
42,0
8,1
47,0
8,1
47,0
8,7
56,0
8,7
56,0
10,3
69,0

Weight
approx.
kg/km
46,0
56,0
56,0
62,0
62,0
75,0
75,0
98,0

AWG-No.
20
20
20
20
20
20
20
20


Part no.
15225
15226
15227
15228
15229
15230
15231
15232

No.cores x
cross-sec.
mm
10G0,5
12G0,5
18G0,5
20G0,5
25G0,5
2x0,75
3G0,75
3x0,75

Outer
Cop.
approx. mm weight
kg/km
12,1
94,0
12,7
108,0
14,9
145,0
15,8
172,0
17,7
240,0
7,3
40,0
7,7
52,0
7,7
52,0

Weight
approx.
kg/km
135,0
158,0
216,0
240,0
315,0
60,0
68,0
68,0

AWG-No.
20
20
20
20
20
18
18
18

Continuation

N 60
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MEGAFLEX 600-C halogen-free, flame retardant, oil-resistant,


UV-resistant, flexible, meter marking

Part no.
15233
15234
15235
15236
15237
15238
15239
15240
15241
15242
15243
15244
15245
15247
15246
15248
15249
15250
15251
15252
15253
15254
15255
15256
15257
15258

No.cores x
cross-sec.
mm
4G0,75
4x0,75
5G0,75
5x0,75
7G0,75
7x0,75
12G0,75
18G0,75
20G0,75
25G0,75
2x1
3G1
3x1
4G1
4G1
5G1
10G1
12G1
18G1
20G1
25G1
2x1,5
3G1,5
3x1,5
4G1,5
5G1,5

Outer
Cop.
approx. mm weight
kg/km
8,5
60,0
8,5
60,0
9,3
71,0
9,3
71,0
10,7
91,0
10,7
91,0
13,1
142,0
16,2
212,0
17,2
238,0
19,5
281,0
8,0
50,0
8,6
60,0
8,6
60,0
9,4
71,0
9,4
71,0
10,4
88,0
14,9
150,0
14,5
184,0
17,9
260,0
19,0
317,0
21,7
349,0
9,0
63,0
9,7
80,0
9,7
80,0
10,5
97,0
11,6
119,0

Weight
approx.
kg/km
78,0
78,0
95,0
95,0
130,0
130,0
203,0
290,0
320,0
413,0
66,0
80,0
80,0
100,0
100,0
130,0
232,0
260,0
382,0
440,0
540,0
88,0
100,0
100,0
125,0
158,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16


Part no.
15259
15260
15261
15262
15263
15264
15265
15266
15267
15268
15269
15270
15271
15272
15273
15274
15275
15276
15277
15278
15279
15280
15281
15282
15283

No.cores x
cross-sec.
mm
7G1,5
10G1,5
12G1,5
18G1,5
20G1,5
25G1,5
2x2,5
3G2,5
4G2,5
5x2,5
7G2,5
10G2,5
12G2,5
3G4
4G4
5G4
7G4
3G6
4G6
5G6
7G6
3G10
4G10
5G10
7G10

Outer
Cop.
approx. mm weight
kg/km
13,9
147,0
16,7
193,0
17,2
267,0
20,5
374,0
21,7
396,0
24,7
526,0
10,2
96,0
10,7
144,0
11,9
148,0
13,2
181,0
15,8
255,0
17,0
340,0
19,2
441,0
13,1
174,0
14,6
230,0
16,1
273,0
17,6
316,0
14,9
240,0
16,4
305,0
18,1
439,0
20,1
505,0
16,6
350,0
18,1
535,0
20,6
592,0
22,6
810,0

Weight
approx.
kg/km
210,0
315,0
340,0
480,0
545,0
702,0
132,0
168,0
195,0
256,0
345,0
482,0
572,0
251,0
305,0
388,0
504,0
351,0
464,0
546,0
670,0
574,0
785,0
914,0
1308,0

AWG-No.
16
16
16
16
16
16
14
14
14
14
14
14
14
12
12
12
12
10
10
10
10
8
8
8
8

Dimensions and specifications may be changed without prior notice. (RA03)

N 61
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTIFLEX 600 highly flexible, oil-resistant, open installation


TC-ER, PLTC-ER, NFPA 79 Edition 2007


Technical data

Cable structure

Properties

Highly-flexible PVC control cable according


to UL Standard 1277
Temperature range
Flexing -5 C to +90 C
Fixed installation -40 C to +90 C
Nominal voltage
TC 600 V
TC Wind Turbine (WTTC) 1000 V
Test voltage 3000 V
Minimum bending radius
Permanently flexing
7,5x cable
Insulation resistance
Min. 20 MOhm x km
Radiation resistance
Up to 80x106 cJ/kg(up to 80 Mrad) 

Bare copper conductor, extra-fine wire


stranded, with AWG measures
Special PVC core insulation with transparent
nylon skin
Black cores with continuous white
numbering
Green-yellow earth core in the outer layer
(3 cores and more)
Cores stranded in layers with optimal
lay-lengths
Separator
Special PVC outer sheath
Sheath colour - black (RAL 9005)
With length marking in feet

Self-extinguishing and flame retardant in


accordance with CSA FT4
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
UV-resistant
Tests
UL:
TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER
(AWG 18 - AWG 12), MTW, NFPA 79 2007.
WTTC 1000 V, DP-1, OIL RES I&II, 90 C dry
/ 75 C wet, Class 1 Div. 2 per NEC Art 336,
392, 501, crush impact test in accordance
withUL 1277
CSA:
c(UL) CIC-TC FT4, CSA AWM I/II A/B FT4


Note

Advantages
Highly-flexible, simple installation
Available on request
with blue cores (DC)
with red cores (AC)
Grey or TPE outer sheath


Application

HELUKABELMULTIFLEX 600 is a highly-flexible, oil-resistant control cable. The special combination of TC-ER, PLTC-ER and ITC-ER allows this
cable to be used as a connecting cable for industrial plant and machinery in accordance with NFPA 79 2007. Approved for open, unprotected
installation in cable trays to the machine. Its outstanding oil resistance (OIL RES I & II) guarantees a long service life; for industrial applications
in dry, damp and wet environments. Recommended applications: production lines, bottling plants, machine construction, switch cabinets,
conveyor systems, packaging machines, automotive industry.
Please observe applicable installation regulations for use in energy supply chains.
= The product conforms to the EG Low-Voltage Directive 2006/95/EG



Part no.
62502
62503
62504
62505
62506
62507
62508
62509
62510
62511
62512
62513
62514
62515
62516
62517
62518
62519
62520
62521
62522
62523
62524
62525
62526
62527
62528

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5
34G0,5
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
15G0,75
18G0,75
25G0,75
34G0,75
36G0,75
42G0,75
3G1,5
4G1,5
5G1,5
7G1,5
9G1,5
12G1,5
18G1,5

AWG-No. Outer
approx.
mm
20
6,9
20
7,3
20
8,0
20
8,6
20
9,9
20
11,4
20
14,2
20
17,0
20
18,9
18
7,8
18
8,6
18
9,3
18
10,8
18
12,4
18
13,8
18
15,4
18
18,5
18
20,5
18
20,6
18
22,3
16
8,6
16
9,5
16
10,3
16
12,0
16
14,2
16
14,7
16
17,2

Cop.
weight
kg/km
10,0
14,0
19,0
24,0
34,0
58,0
86,0
120,0
163,0
22,0
29,0
36,0
50,0
86,0
108,0
130,0
180,0
245,0
259,0
302,0
43,0
58,0
72,0
101,0
130,0
173,0
259,0

Weight
approx.
kg/km
53,0
61,0
72,0
85,0
110,0
158,0
241,0
316,0
439,0
75,0
91,0
103,0
136,0
228,0
273,0
311,0
498,0
550,0
570,0
600,0
100,0
122,0
148,0
197,0
244,0
328,0
459,0


Part no.
62529
62530
62531
62532
62533
62534
63136
62535
62536
62537
62538
62539
62540
62541
62542
62543
62544
62545
62546
62547
62548
62549
62550
62551
62552
62554

No.cores x
cross-sec.
mm
25G1,5
34G1,5
41G1,5
50G1,5
60G1,5
3G2,5
4G2,5
5G2,5
7G2,5
9G2,5
12G2,5
18G2,5
25G2,5
3G4
4G4
5G4
7G4
4G6
5G6
7G6
4G10
5G10
4G16
5G16
4G25
4G35

AWG-No. Outer
approx.
mm
16
20,8
16
23,0
16
25,1
16
27,7
16
29,5
14
9,8
14
10,6
14
11,9
14
13,6
14
16,1
14
16,9
14
20,1
14
25,1
12
11,3
12
12,4
12
13,8
12
16,9
10
15,3
10
16,6
10
18,2
8
19,7
8
22,0
6
23,7
6
26,1
4
34,0
2
37,0

Cop.
weight
kg/km
360,0
490,0
590,0
720,0
864,0
72,0
96,0
120,0
168,0
216,0
288,0
432,0
600,0
115,0
154,0
192,0
269,0
230,0
288,0
403,0
384,0
480,0
614,0
768,0
960,0
1344,0

Weight
approx.
kg/km
665,0
1084,0
1260,0
1521,0
1885,0
160,0
173,0
268,0
307,0
437,0
572,0
800,0
1100,0
221,0
247,0
318,0
438,0
383,0
481,0
800,0
671,0
990,0
951,0
1500,0
1700,0
2300,0

Dimensions and specifications may be changed without prior notice. (RN01)

N 62
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTIFLEX 600-C highly-flexible, oil-resistant, screened,


EMC-preferred type, control cable for open installation TC-ER, PLTC-ER, NFPA 79
Edition 2007


Technical data

Cable structure

Properties

Highly-flexible PVC control cable according


to UL Standard 1277
Temperature range
Flexing -5 C to +90 C
Fixed installation -40 C to +90 C
Nominal voltage
TC 600 V
TC Wind Turbine (WTTC) 1000 V
Test voltage 3000 V
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
Permanently flexing
10x cable
Insulation resistance
Min. 20 MOhm x km
Radiation resistance
Up to 80x106 cJ/kg(up to 80 Mrad) 

Bare copper conductor, extra-fine wire


stranded, with AWG measures
Special PVC core insulation with transparent
nylon skin
Black cores with continuous white
numbering
Green-yellow earth core in the outer layer
(3 cores and more)
Cores stranded in layers with optimal
lay-lengths
Separating foil
Braided screening of tinned copper wires,
coverage approx. 85% 
Separator
Special PVC outer sheath
Sheath colour - black (RAL 9005)
With length marking in feet

Self-extinguishing and flame retardant in


accordance with CSA FT4
The materials used in manufacture are free
of silicone, cadmium and substances that
impair paint wetting
UV-resistant
Tests
UL:
TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER
(AWG 18 - AWG 12), MTW, NFPA 79 2007.
WTTC 1000 V, DP-1, OIL RES I&II, 90 C dry
/ 75 C wet, Class 1 Div. 2 per NEC Art 336,
392, 501, crush impact test in accordance
with UL 1277
CSA:
c(UL) CIC-TC FT4, CSA AWM I/II A/B FT4


Note

Advantages
Highly-flexible, simple installation
Available on request
with blue cores (DC)
with red cores (AC)
Grey or TPE outer sheath


Application
HELUKABEL MULTIFLEX 600-C is ahighly-flexible, screened, oil-resistant control cable. The special combination of TC-ER, PLTC-ER and ITC-ER
allows this cable to be used as a connecting cable for industrial plant and machinery in accordance with NFPA 79 2007. Approvedfor open,
unprotected installation in cable trays to the machine. Its outstanding oil resistance (OIL RES I &II) guarantees a long service life; for industrial
applications in dry, damp and wet environments. Recommended applications: Production lines, bottling plants, machine construction, switch
cabinets, conveyor systems, packaging machines, automotive industry.
Please observe applicable installation regulations for use in energy supply chains.
EMC = Electromagnetic compatibility. Tooptimise EMC characteristics, we recommend a large contact area for the copper braiding around
the entire circumference on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
62556
62557
62558
62559
62560
62561
62562
62563
62564
62565
62566
62567
62568
62569
62570
62571
62572
62573
62574
62575
62576
62577
62578
62579

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5
34G0,5
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
15G0,75
18G0,75
25G0,75
34G0,75
3G1,5
4G1,5
5G1,5
7G1,5
9G1,5
12G1,5

AWG-No. Outer
approx.
mm
20
7,7
20
8,0
20
8,7
20
9,3
20
10,7
20
12,3
20
15,1
20
18,1
20
19,8
18
8,5
18
9,3
18
10,0
18
11,6
18
14,1
18
15,2
18
16,3
18
19,6
18
21,9
16
9,3
16
10,2
16
11,0
16
12,9
16
15,2
16
15,6

Cop.
weight
kg/km
30,0
37,0
46,0
54,0
70,0
112,0
153,0
225,0
267,0
55,0
69,0
82,0
119,0
178,0
175,0
252,0
362,0
473,0
75,0
93,0
113,0
162,0
193,0
249,0

Weight
approx.
kg/km
80,0
85,0
100,0
113,0
152,0
210,0
304,0
408,0
530,0
101,0
127,0
148,0
186,0
286,0
455,0
383,0
514,0
685,0
131,0
165,0
195,0
250,0
340,0
393,0


Part no.
62580
62581
62582
62583
62584
62585
62586
62587
62588
62589
62590
62591
62592
62593
62594
62595
62596
62597
62598
62599
62600
62602
62603
62605

No.cores x
cross-sec.
mm
18G1,5
25G1,5
34G1,5
3G2,5
4G2,5
5G2,5
7G2,5
9G2,5
12G2,5
18G2,5
25G2,5
3G4
4G4
5G4
7G4
4G6
5G6
7G6
4G10
5G10
4G16
5G16
4G25
4G35

AWG-No. Outer
approx.
mm
16
18,4
16
23,1
16
25,8
14
10,3
14
11,5
14
12,4
14
15,4
14
16,8
14
18,5
14
22,4
14
25,5
12
11,7
12
13,3
12
14,7
12
17,8
10
16,1
10
17,5
10
20,6
8
21,9
8
24,1
6
24,8
6
27,2
4
33,1
2
37,8

Cop.
weight
kg/km
376,0
510,0
674,0
141,0
149,0
195,0
243,0
312,0
368,0
639,0
796,0
180,0
221,0
330,0
363,0
314,0
441,0
505,0
526,0
610,0
730,0
1050,0
1450,0
37,0

Weight
approx.
kg/km
559,0
788,0
1203,0
218,0
222,0
350,0
373,0
479,0
730,0
1140,0
1530,0
296,0
305,0
450,0
536,0
469,0
772,0
1028,0
790,0
1096,0
1621,0
1759,0
2100,0
2550,0

Dimensions and specifications may be changed without prior notice. (RN01)

N 63
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N
Command Cable UL (LiYY)
Command Cable UL (LiYY-TP)
Command Cable UL (LiYCY)
Command Cable UL (LiYCY-TP)
Photo: HELUKABEL

UL/CSA Data Cables

N 64
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Command Cable UL (LiYY) Style2464/300V,(80C)




Technical data

Cable structure

Properties

Special PVC command cable, approved to


UL-Style2464, cores according
AWG 26-20 to UL-Style1061/1729
AWG 18-16 to UL-Style1007/1569
Temperature range
flexing -10 C to +80 C
fixed installation -20 C to +80 C
Nominal voltage 300 V
Test voltage 1500 V
Breakdown voltage
min. 3000 V
Minimum bending radius
fixedapprox. 7,5x cable
flexing approx. 15 cable

Tinned copper, fine wire conductors


AWG 26-20, gem ASTM-B174-95
classJ-M,
AWG 18-16 gem ASTM-B286
Conductor make-up to:
0,14 mm = 7x0,162 mm
0,23 mm = 7x0,202 mm
0,34 mm = 7x0,254 mm
0,56 mm = 7x0,32 mm
0,82 mm = 19x0,235 mm
1,30 mm = 19x0,31 mm
Special PVC core insulation class 43,
semirigid to UL-Std. 1581 table 50.182 and
50.183
Colour coded to DIN 47100 or international
colour code
Cores stranded in layers with optimal
lay-length
Special PVC outer jacket class43 to
UL-Std.1581 table50.182
Outer jacket colour
black (international colour code)
grey (DIN 47100 / preferred type for stock)

PVC flame retardant according to UL


VW-1/CSA FT1
Conditionally resistant to
Oil
Solvents
Acids
Lyes
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers



Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
screened analogue type:
Command Cable UL (LIYCY),
see page N 69

Application
Suitable for use as a command, measuring and control cable in tool making machinery conveyor system and production lines, in industrial
plants and in air conditioning as well as in the steel producing industries.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
Jacket
colour
grey
83137
83138
83139
83140
83141
83142
83143
83144
83145
83146
83147
83153
83154
83155
83156
83157
83158
83159
83160
83161
83162
83163
83169
83170
83171
83172
83173
83174
83175
83176
83177
83178
83179
83185
83186
83187

Part no.
Jacket
colour
black
83045
83046
83047
83048
83049
83050
83055
83056
83057
83058
83059
83130
83131
83132
83133
83134
83135
83136
83371
83372
83373
83374
83375
83376
83377
83378
83379
83380
83381
83382
83383
83384
83385
83386
83387
83388

No.cores x AWG-No. Outer Cop.


Weight
cross-sec.
approx. weight approx.
mm
mm
kg/km kg/km
2x0,14
3x0,14
4x0,14
6x0,14
10x0,14
12x0,14
16x0,14
18x0,14
24x0,14
27x0,14
30x0,14
2x0,23
3x0,23
4x0,23
6x0,23
10x0,23
12x0,23
16x0,23
18x0,23
24x0,23
27x0,23
30x0,23
2x0,34
3x0,34
4x0,34
6x0,34
10x0,34
12x0,34
16x0,34
18x0,34
24x0,34
27x0,34
30x0,34
2x0,56
3x0,56
4x0,56

26
26
26
26
26
26
26
26
26
26
26
24
24
24
24
24
24
24
24
24
24
24
22
22
22
22
22
22
22
22
22
22
22
20
20
20

3,6
3,8
4,0
4,6
5,6
5,8
6,3
6,6
7,5
7,6
8,0
3,8
4,0
4,3
4,9
6,0
6,2
6,8
7,1
8,1
8,4
8,9
4,1
4,3
4,6
5,4
6,6
6,8
7,5
8,1
9,4
9,7
10,2
4,6
4,8
5,2

3,6
4,0
5,4
8,1
13,4
16,2
21,5
34,4
32,4
36,3
40,4
4,6
7,1
9,4
14,2
23,8
28,5
38,1
43,1
59,7
64,7
71,9
6,5
9,8
13,0
19,6
32,5
39,1
52,0
59,0
79,0
88,0
97,8
9,8
14,6
19,4

13,0
15,0
18,0
25,0
38,0
46,0
56,0
62,0
82,0
97,0
110,0
16,0
19,0
23,0
32,0
55,0
60,0
75,0
82,0
116,0
140,0
150,0
25,0
30,0
45,0
60,0
80,0
105,0
130,0
140,0
190,0
207,0
225,0
30,0
33,0
41,0


Part no.
Jacket
colour
grey
83188
83189
83190
83191
83192
83193
83194
83195
83201
83202
83203
83204
83205
83206
83207
83208
83209
83210
83211
83217
83218
83219
83220
83221
83222
83223
83224
83225
83226
83227

Part no.
Jacket
colour
black
83389
83390
83391
83392
83393
83394
83395
83396
83397
83398
83399
83474
83475
83476
83477
83478
83479
83480
83481
83482
83483
83484
83491
83492
83493
83494
83495
83496
83497
83498

No.cores x AWG-No. Outer Cop.


Weight
cross-sec.
approx. weight approx.
mm
mm
kg/km kg/km
6x0,56
10x0,56
12x0,56
16x0,56
18x0,56
24x0,56
27x0,56
30x0,56
2x0,82
3x0,82
4x0,82
6x0,82
10x0,82
12x0,82
16x0,82
18x0,82
24x0,82
27x0,82
30x0,82
2x1,3
3x1,3
4x1,3
6x1,3
10x1,3
12x1,3
16x1,3
18x1,3
24x1,3
27x1,3
30x1,3

20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
16
16
16
16
16
16
16
16
16
16
16

6,1
7,6
7,8
8,7
9,3
10,9
11,2
11,8
6,1
6,4
6,9
8,1
10,4
10,9
12,2
13,0
15,2
15,8
16,3
6,6
7,0
7,6
9,2
11,8
12,2
13,7
14,6
17,0
17,6
18,6

29,0
48,2
58,2
77,3
87,0
116,3
129,8
144,6
15,2
23,2
31,3
47,0
78,2
94,0
125,1
141,1
188,2
212,0
235,6
24,4
37,1
49,4
74,2
124,0
149,0
198,7
224,0
298,4
336,0
373,6

65,0
102,0
120,0
152,0
168,0
224,0
260,0
300,0
50,0
62,0
72,0
100,0
180,0
182,0
240,0
270,0
370,0
400,0
470,0
70,0
90,0
110,0
160,0
250,0
300,0
400,0
450,0
650,0
680,0
750,0

Dimensions and specifications may be changed without prior notice. (RN02)

N 65
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Command Cable UL (LiYY) 600V, Style2516/600V,(105C)




Technical data

Cable structure

Properties

Special PVC command cable, approved to


UL-Style2516
Temperature range
flexing -10 C to +105 C
fixed installation -20 C to +105 C
Nominal voltage 600 V
Test voltage 2000 V
Breakdown voltage
min. 4000 V
Minimum bending radius
fixed approx. 7,5 cable
flexing approx. 15 cable

Tinned copper, fine wire conductors to


ASTM-B174, classJ-K
Conductor make-up to:
2,08 mm = 41x0,254mm
3,20 mm = 65x0,254mm
Special PVC core insulation class43 to
UL-Std.1581 table50.182 (105 C)
Colour coded to DIN47100 or international
colour code
Cores stranded in layers with optimal
lay-length
Special PVC outer jacket class43 to
UL-Std.1581 table50.182 (105 C)
Outer jacket colour
black (international colour code)
grey (DIN 47100 / preferred type from
stock)

PVC flame retardant according to UL


VW-1/CSA FT1
Conditionally resistant to
Oil
Solvents
Acids
Lyes
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers



Application

Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
screened analogue type:
Command Cable UL (LIYCY),
see page N 69

Suitable for use as a command, measuring and control cable in tool making machinery conveyor system and production lines, in industrial
plants and in air conditioning as well as in the steel producing industries.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
Jacket
colour
grey
83233
83234
83235
83236
83237
83238
83239
83240
83241
83242
83243
83244

Part no.
Jacket
colour
black
83624
83625
83626
83627
83628
83629
83630
83631
83632
83633
83634
83635

No.cores x AWG-No. Outer Cop.


Weight
cross-sec.
approx. weight approx.
mm
mm
kg/km kg/km
2x2,08
3x2,08
4x2,08
6x2,08
10x2,08
12x2,08
16x2,08
18x2,08
24x2,08
27x2,08
30x2,08
36x2,08

14
14
14
14
14
14
14
14
14
14
14
14

8,4
8,9
9,6
11,4
15,1
15,6
17,2
18,3
21,5
22,7
23,5
25,4

39,6
59,6
79,2
119,0
198,4
238,7
319,0
358,4
478,4
538,1
598,4
717,2

120,0
150,0
190,0
300,0
450,0
500,0
700,0
750,0
900,0
1100,0
1150,0
1800,0


Part no.
Jacket
colour
grey
83245
83246
83247
83248
83249
83250
83251
83252
83253

Part no.
Jacket
colour
black
83636
83637
83638
83639
83640
83641
83642
83643
83644

No.cores x AWG-No. Outer Cop.


Weight
cross-sec.
approx. weight approx.
mm
mm
kg/km kg/km
2x3,2
3x3,2
4x3,2
6x3,2
10x3,2
12x3,2
16x3,2
18x3,2
24x3,2

12
12
12
12
12
12
12
12
12

9,3
9,8
10,8
12,8
17,0
17,5
19,8
21,0
24,8

61,0
91,4
121,6
183,7
305,9
367,6
490,9
551,7
736,4

150,0
210,0
300,0
430,0
500,0
700,0
810,0
970,0
1200,0

Dimensions and specifications may be changed without prior notice. (RN02)

N 66
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Command Cable UL (LiYY-TP) Style2464/300V, 80C




Technical data

Cable structure

Properties

Special PVC command cable, approved to


UL-Style2464,cores according,
UL-Style1061/1729
Temperature range
flexing -10 C to +80 C
fixed installation -20 C to +80 C
Nominal voltage 300 V
Test voltage 1500 V
Breakdown voltage
min. 3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
fixed approx. 7,5 cable
flexing approx. 15 cable

Tinned copper, fine wire conductors to


ASTM-B174-95 classJ-M
conductor make-up to
0,14 mm = 7x0,162mm
0,23 mm = 7x0,202mm
0,34 mm = 7x0,254mm
0,56 mm = 7x0,32mm
Special PVC core insulation class43,
semirigid to UL-Std.1581 table50.182
and50183
Colour coded to DIN47100 with colour
repetition from pair no.23 and above or
international colour code
Cores stranded in pairs with optimal
lay-length
Pairs stranded in layers with optimal
lay-length
Seperator-foil
Special PVC outer jacket class43 to
UL-Std.1581 table50.182
Outer jacket colour
black (international colour code)
grey (DIN 47100 / preferred type)

PVC flame retardant according to UL


VW-1/CSA FT1
Conditionally resistant to
Oil
Solvents
Acids
Lyes
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers



Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
screened analogue type:
Command Cable UL (LiYCY-TP),
see page N 72

Application
Twisted pair control cable for use in tool making machinery conveyor system and production lines, in industrial plants and in air conditioning
as well as in the steel producing industries.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.pairs x


Jacket
cross-sec.
colour
mm
grey
83904
1 x 2 x 0,14
83905
2 x 2 x 0,14
83906
3 x 2 x 0,14
83907
4 x 2 x 0,14
83908
5 x 2 x 0,14
83909
6 x 2 x 0,14
83910
7 x 2 x 0,14
83911
8 x 2 x 0,14
83912
10 x 2 x 0,14
83913
12 x 2 x 0,14
83914
14 x 2 x 0,14
83915
15 x 2 x 0,14
83916
16 x 2 x 0,14
83917
18 x 2 x 0,14
83918
20 x 2 x 0,14
83919
22 x 2 x 0,14
83920
24 x 2 x 0,14
83921
25 x 2 x 0,14
83922
1 x 2 x 0,23
83923
2 x 2 x 0,23
83924
3 x 2 x 0,23
83925
4 x 2 x 0,23
83926
5 x 2 x 0,23
83927
6 x 2 x 0,23
83928
7 x 2 x 0,23
83929
8 x 2 x 0,23
83930
10 x 2 x 0,23
83931
12 x 2 x 0,23
83932
14 x 2 x 0,23

AWG-No. Outer Cop.


Weight
approx. weight approx.
mm
kg/km kg/km
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
24
24
24
24
24
24
24
24
24
24
24

3,6
5,1
5,3
5,8
6,2
6,8
6,8
7,3
7,4
9,1
9,8
10,6
10,6
11,1
11,9
12,4
13,1
13,4
3,8
5,4
5,7
6,2
6,6
7,2
7,2
7,8
9,2
9,7
10,2

2,7
5,4
8,1
10,8
13,6
16,2
19,0
21,7
26,7
32,6
37,4
40,7
43,4
48,5
54,2
59,3
64,7
67,2
4,8
9,7
14,7
19,6
24,6
29,3
34,1
39,1
48,9
59,4
68,7

20,0
24,0
30,0
38,0
44,0
51,0
57,0
64,0
76,0
93,0
103,0
109,0
112,0
119,0
130,0
150,0
169,0
178,0
32,0
36,0
48,0
56,0
71,0
80,0
89,0
98,0
111,0
135,0
160,0


Part no. No.pairs x
Jacket
cross-sec.
colour
mm
black
65214
1 x 2 x 0,14
65215
2 x 2 x 0,14
65216
3 x 2 x 0,14
65217
4 x 2 x 0,14
65218
5 x 2 x 0,14
65219
6 x 2 x 0,14
65220
7 x 2 x 0,14
65221
8 x 2 x 0,14
65222
10 x 2 x 0,14
65223
12 x 2 x 0,14
65224
14 x 2 x 0,14
65225
15 x 2 x 0,14
65226
16 x 2 x 0,14
65227
18 x 2 x 0,14
65228
20 x 2 x 0,14
65229
22 x 2 x 0,14
65230
24 x 2 x 0,14
65231
25 x 2 x 0,14
65232
1 x 2 x 0,22
65233
2 x 2 x 0,22
65234
3 x 2 x 0,22
65235
4 x 2 x 0,22
65236
5 x 2 x 0,22
65237
6 x 2 x 0,22
65238
7 x 2 x 0,22
65239
8 x 2 x 0,22
65240
10 x 2 x 0,22
65241
12 x 2 x 0,22
65242
14 x 2 x 0,22

AWG-No. Outer Cop.


Weight
approx. weight approx.
mm
kg/km kg/km
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
24
24
24
24
24
24
24
24
24
24
24

3,6
5,1
5,3
5,8
6,2
6,8
6,8
7,3
7,4
9,1
9,8
10,6
10,6
11,1
11,9
12,4
13,1
13,4
3,8
4,0
5,7
2,0
6,0
7,2
7,2
7,8
9,2
9,7
10,2

2,7
5,4
8,1
10,8
13,6
16,2
19,0
21,7
26,7
32,6
37,4
40,7
43,4
48,5
54,2
59,3
64,7
67,2
4,8
9,7
14,7
19,6
24,6
29,3
34,1
39,1
48,9
59,4
68,7

20,0
24,0
30,0
38,0
44,0
51,0
57,0
64,0
76,0
93,0
103,0
109,0
112,0
119,0
130,0
150,0
169,0
178,0
32,0
36,0
48,0
56,0
56,0
80,0
89,0
98,0
111,0
135,0
160,0

Continuation

N 67
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Command Cable UL (LiYY-TP) Style2464/300V, 80C



Part no. No.pairs x
Jacket
cross-sec.
colour
mm
grey
83933
15 x 2 x 0,23
83934
16 x 2 x 0,23
83935
18 x 2 x 0,23
83936
20 x 2 x 0,23
83937
22 x 2 x 0,23
83938
24 x 2 x 0,23
83939
25 x 2 x 0,23
83940
1 x 2 x 0,34
83941
2 x 2 x 0,34
83942
3 x 2 x 0,34
83943
4 x 2 x 0,34
83944
5 x 2 x 0,34
83945
6 x 2 x 0,34
83946
7 x 2 x 0,34
83947
8 x 2 x 0,34
83948
10 x 2 x 0,34
83949
12 x 2 x 0,34
83950
14 x 2 x 0,34
83951
15 x 2 x 0,34
83952
16 x 2 x 0,34
83953
18 x 2 x 0,34
83954
20 x 2 x 0,34
83955
22 x 2 x 0,34
83956
24 x 2 x 0,34
83957
25 x 2 x 0,34
83958
1 x 2 x 0,56
83959
2 x 2 x 0,56
83960
3 x 2 x 0,56
83961
4 x 2 x 0,56
83962
5 x 2 x 0,56
83963
6 x 2 x 0,56
83964
7 x 2 x 0,56
83965
8 x 2 x 0,56
83966
10 x 2 x 0,56
83967
12 x 2 x 0,56
83968
14 x 2 x 0,56
83969
15 x 2 x 0,56
83970
16 x 2 x 0,56
83971
18 x 2 x 0,56
83972
20 x 2 x 0,56
83973
22 x 2 x 0,56
83974
24 x 2 x 0,56
83975
25 x 2 x 0,56

AWG-No. Outer Cop.


Weight
approx. weight approx.
mm
kg/km kg/km
24
24
24
24
24
24
24
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

10,9
10,9
11,5
12,2
13,0
13,7
14,2
4,2
5,9
6,3
7,0
7,6
8,2
8,2
9,0
10,7
11,3
12,1
12,7
12,7
13,6
14,4
15,1
16,2
16,7
4,6
6,5
7,1
7,8
8,6
9,6
9,6
12,2
12,5
13,1
13,8
14,7
14,7
15,7
16,7
17,2
18,6
19,2

73,7
79,1
88,9
98,4
108,6
117,9
123,5
6,5
13,0
19,5
26,1
32,6
39,2
45,7
52,3
65,3
78,4
91,5
97,8
104,6
117,8
130,7
143,6
156,8
163,3
10,8
21,5
32,3
43,1
53,8
64,6
75,3
86,1
107,7
129,1
150,6
161,3
172,1
193,6
215,1
236,6
258,0
268,9

171,0
185,0
209,0
230,0
248,0
279,0
292,0
38,0
44,0
60,0
79,0
92,0
119,0
128,0
139,0
171,0
194,0
222,0
231,0
240,0
264,0
291,0
300,0
359,0
381,0
60,0
80,0
94,0
104,0
130,0
151,0
174,0
262,0
298,0
302,0
327,0
370,0
402,0
480,0
551,0
621,0
703,0
721,0


Part no. No.pairs x
Jacket
cross-sec.
colour
mm
black
65243
15 x 2 x 0,22
65244
16 x 2 x 0,22
65245
18 x 2 x 0,22
65246
20 x 2 x 0,22
65247
22 x 2 x 0,22
65248
24 x 2 x 0,22
65249
25 x 2 x 0,22
65250
1 x 2 x 0,34
65251
2 x 2 x 0,34
65252
3 x 2 x 0,34
65253
4 x 2 x 0,34
65254
5 x 2 x 0,34
65255
6 x 2 x 0,34
65256
7 x 2 x 0,34
65257
8 x 2 x 0,34
65258
10 x 2 x 0,34
65259
12 x 2 x 0,34
65260
14 x 2 x 0,34
65261
15 x 2 x 0,34
65262
16 x 2 x 0,34
65263
18 x 2 x 0,34
65264
20 x 2 x 0,34
65265
22 x 2 x 0,34
65266
24 x 2 x 0,34
65267
25 x 2 x 0,34
65268
1 x 2 x 0,56
65269
2 x 2 x 0,56
65270
3 x 2 x 0,56
65271
4 x 2 x 0,56
65272
5 x 2 x 0,56
65273
6 x 2 x 0,56
65274
7 x 2 x 0,56
65275
8 x 2 x 0,56
65276
10 x 2 x 0,56
65277
12 x 2 x 0,56
65278
14 x 2 x 0,56
65279
15 x 2 x 0,56
65280
16 x 2 x 0,56
65281
18 x 2 x 0,56
65282
20 x 2 x 0,56
65283
22 x 2 x 0,56
65284
24 x 2 x 0,56
65285
25 x 2 x 0,56

AWG-No. Outer Cop.


Weight
approx. weight approx.
mm
kg/km kg/km
24
24
24
24
24
24
24
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

10,9
10,9
11,5
12,2
13,0
7,0
13,7
4,2
5,9
6,3
7,0
7,6
8,2
8,2
9,0
10,7
11,3
12,1
12,7
12,7
13,6
14,4
15,1
16,2
16,7
4,6
6,5
7,1
7,8
8,6
9,6
9,6
12,1
12,5
13,1
13,8
14,7
14,7
15,7
16,7
17,2
18,6
19,2

73,7
79,1
88,9
98,4
108,6
117,9
123,5
6,5
13,0
19,5
26,1
32,6
39,2
45,7
52,3
65,3
78,4
91,5
97,8
104,6
117,8
130,7
143,6
156,8
163,3
10,8
21,5
32,3
43,1
53,8
64,6
75,3
86,1
107,7
129,1
150,6
161,3
172,1
193,6
215,1
236,6
258,0
268,9

171,0
185,0
209,0
230,0
248,0
279,0
292,0
38,0
44,0
60,0
79,0
92,0
119,0
128,0
139,0
171,0
194,0
222,0
231,0
240,0
264,0
291,0
300,0
359,0
381,0
60,0
80,0
94,0
104,0
130,0
151,0
174,0
262,0
298,0
302,0
327,0
370,0
402,0
480,0
551,0
621,0
703,0
721,0

Dimensions and specifications may be changed without prior notice. (RN02)

N 68
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Command Cable UL (LiYCY) Style 2464, 300V, 80C,


EMC-preferred type


Technical data

Cable structure

Properties

Special PVC command cable, approved to


UL-Style2464, cores according
AWG 26-20 to UL-Style1061/1729
AWG 18-16 to UL-Style1007/1569
Temperature range
flexing -10 C to +80 C
fixed installation -20 C to +80 C
Nominal voltage 300 V
Test voltage 1500 V
Breakdown voltage
min. 3000 V
Minimum bending radius
fixed approx. 7,5 cable
flexing approx. 15 cable
Coupling resistance
max. 250 Ohm/km

Tinned copper, fine wire conductors


AWG 26-20 gem. ASTM-B174-95 classJ-M,
AWG 18-16 gem. ASTM-B286
conductor make-up to
0,14 mm = 7x0,162 mm
0,23 mm = 7x0,202 mm
0,34 mm = 7x0,254 mm
0,56 mm = 7x0,32 mm
0,82 mm = 19x0,235 mm
1,30 mm = 19x0,31 mm
Special PVC core insulation class43,
semirigid to UL-Std.1581 table50.182
and50.183
Colour coded to DIN47100 or international
colour code
Cores stranded in layers with optimal
lay-length
Seperator-foil
Drain wire
Tinned copper wire braiding, approx. 85%
coverage
Special PVC outer jacket class43 to
UL-Std.1581 table50.182
Outer jacket colour
black (international colour code)
grey (DIN 47100 / preferred type from
stock)

PVC flame retardant according to UL


VW-1/CSA FT1
Conditionally resistant to
Oil
Solvents
Acids
Lyes
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
non-screened analogue types:
Command Cable UL (LiYY),
see page N 65

Application
This cable type is suitable for use as a flexible connector cable in the fields of electronics, control and command technology as well as for
measuring, signal and impulse transfer. Quick and cost favourable connections through cutting and clamping technics.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
Jacket
colour
grey
83254
83255
83256
83257
83258
83259
83260
83261
83262
83263
83264

Part no.
Jacket
colour
black
83976
83977
83978
83979
83980
83981
83982
83983
83984
83985
83986

No.cores x AWG-No. Outer Cop.


Weight
cross-sec.
approx. weight approx.
mm
mm
kg/km kg/km
2x0,14
3x0,14
4x0,14
6x0,14
10x0,14
12x0,14
16x0,14
18x0,14
24x0,14
27x0,14
30x0,14

26
26
26
26
26
26
26
26
26
26
26

3,9
4,2
4,4
5,0
6,1
6,3
6,8
7,1
8,0
8,4
8,6

12,6
13,7
14,9
18,9
29,5
31,4
43,9
52,1
62,8
66,3
70,4

20,0
25,0
28,0
30,0
50,0
53,0
60,0
70,0
100,0
105,0
110,0


Part no.
Jacket
colour
grey
83270
83271
83272
83273
83274
83275
83276
83277
83278
83279
83280

Part no.
Jacket
colour
black
83987
83988
83989
83990
83991
83992
83993
83994
83995
83996
83997

No.cores x AWG-No. Outer Cop.


Weight
cross-sec.
approx. weight approx.
mm
mm
kg/km kg/km
2x0,23
3x0,23
4x0,23
6x0,23
10x0,23
12x0,23
16x0,23
18x0,23
24x0,23
27x0,23
30x0,23

24
24
24
24
24
24
24
24
24
24
24

4,3
4,5
4,8
5,4
6,5
6,7
7,4
7,7
8,8
9,0
9,3

16,1
18,9
23,0
32,8
50,9
59,1
68,4
79,5
97,3
122,0
132,0

20,0
25,0
30,0
40,0
60,0
70,0
90,0
123,0
131,0
160,0
170,0

Continuation

N 69
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Command Cable UL (LiYCY) Style 2464, 300V, 80C,


EMC-preferred type

Part no.
Jacket
colour
grey
83286
83287
83288
83289
83290
83291
83292
83293
83294
83295
83296
83302
83303
83304
83305
83306
83307
83308
83309
83310
83311
83312

Part no.
Jacket
colour
black
65044
65045
65046
65047
65048
65049
65050
65051
65052
65053
65054
65055
65056
65057
65058
65059
65060
65061
65062
65063
65064
65065

No.cores x AWG-No. Outer Cop.


Weight
cross-sec.
approx. weight approx.
mm
mm
kg/km kg/km
2x0,34
3x0,34
4x0,34
6x0,34
10x0,34
12x0,34
16x0,34
18x0,34
24x0,34
27x0,34
30x0,34
2x0,56
3x0,56
4x0,56
6x0,56
10x0,56
12x0,56
16x0,56
18x0,56
24x0,56
27x0,56
30x0,56

22
22
22
22
22
22
22
22
22
22
22
20
20
20
20
20
20
20
20
20
20
20

4,6
4,8
5,1
6,0
7,3
7,5
8,2
8,7
9,9
10,4
10,9
5,1
5,3
5,6
6,6
8,1
8,4
9,5
9,9
11,5
12,0
12,4

18,1
22,2
28,7
45,4
66,1
70,8
88,4
104,1
129,0
138,4
159,0
29,4
39,7
46,1
66,8
93,1
117,4
130,4
151,4
237,0
257,4
297,0

40,0
50,0
60,0
80,0
130,0
140,0
160,0
170,0
220,0
250,0
280,0
50,0
55,0
61,0
90,0
133,0
151,0
190,0
216,0
339,0
374,0
397,0


Part no.
Jacket
colour
grey
83318
83319
83320
83321
83322
83323
83324
83325
83326
83327
83328
83334
83335
83336
83337
83338
83339
83340
83341
83342
83343
83344

Part no.
Jacket
colour
black
65066
65067
65068
65069
65070
65071
65072
65073
65074
65075
65076
65077
65078
65079
65080
65081
65082
65083
65084
65085
65086
65087

No.cores x AWG-No. Outer Cop.


Weight
cross-sec.
approx. weight approx.
mm
mm
kg/km kg/km
2x0,82
3x0,82
4x0,82
6x0,82
10x0,82
12x0,82
16x0,82
18x0,82
24x0,82
27x0,82
30x0,82
2x1,3
3x1,3
4x1,3
6x1,3
10x1,3
12x1,3
16x1,3
18x1,3
24x1,3
27x1,3
30x1,3

18
18
18
18
18
18
18
18
18
18
18
16
16
16
16
16
16
16
16
16
16
16

6,5
6,8
7,4
8,8
10,9
11,2
12,9
13,5
15,6
15,9
16,6
6,9
7,3
7,9
9,6
12,4
12,8
12,8
15,5
18,1
18,7
19,5

39,1
50,0
59,1
89,1
141,4
152,8
184,1
207,2
272,6
289,1
317,4
59,1
74,1
96,4
137,4
191,7
251,7
276,1
364,1
442,4
494,7
521,4

60,0
75,0
90,0
125,0
180,0
220,0
290,0
300,0
450,0
470,0
490,0
90,0
160,0
200,0
290,0
450,0
600,0
650,0
680,0
900,0
990,0
1050,0

Dimensions and specifications may be changed without prior notice. (RN02)

N 70
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Command Cable UL (LiYCY) Style2516/600V,105C,


EMC-preferred type


Technical data

Cable structure

Properties

Special PVC command cable, approved to


UL-Style2516 cores according
UL-Style10012
Temperature range
flexing -10 C to +105 C
fixed installation -20 C to +105 C
Nominal voltage 600 V
Test voltage 2000 V
Breakdown voltage
min. 4000 V
Minimum bending radius
fixed approx. 7,5 cable
flexing approx. 15 cable
Coupling resistance
max. 250 Ohm/km

Tinned copper, fine wire conductors to


ASTM-B174, classJ-K
conductor make-up to
2,08 mm = 41x0,254 mm
3,20 mm = 65x0,254 mm
Special PVC core insulation class43 to
UL-Std.1581 table50.182 (105 C)
Colour coded to DIN47100 or international
colour code
Cores stranded in layers with optimal
lay-length
Seperator-foil
Drain wire
Tinned copper wire braiding, approx. 85%
coverage
Special PVC outer jacket class43 to
UL-Std.1581 table50.182 (105 C)
Outer jacket colour
black (international colour code)
grey (DIN 47100 / preferred type from
stock)

PVC flame retardant according to UL


VW-1/CSA FT1
Conditionally resistant to
Oil
Solvents
Acids
Lyes
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
non-screened analogue types:
Command Cable UL (LiYY),
see page N 65

Application
This cable type is suitable for use as a flexible connector cable in the fields of electronics, control and command technology as well as for
measuring, signal and impulse transfer. Quick and cost favourable connections through cutting and clamping technics.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
Jacket
colour
grey
83350
83351
83352
83353
83354
83355
83356
83357
83358
83359
83360

Part no.
Jacket
colour
black
65114
65115
65116
65117
65118
65119
65120
65121
65122
65123
65124

No.cores x AWG-No. Outer Cop.


Weight
cross-sec.
approx. weight approx.
mm
mm
kg/km kg/km
2x2,08
3x2,08
4x2,08
6x2,08
10x2,08
12x2,08
16x2,08
18x2,08
24x2,08
27x2,08
30x2,08

14
14
14
14
14
14
14
14
14
14
14

9,1
9,6
10,4
12,1
16,0
16,5
18,1
19,4
23,4
23,9
24,6

92,1
140,6
162,4
200,0
313,1
417,6
510,3
540,4
580,6
604,2
660,1

180,0
220,0
270,0
380,0
600,0
770,0
870,0
990,0
1300,0
1400,0
1610,0


Part no.
Jacket
colour
grey
83362
83363
83364
83365
83366
83367
83368
83369
83370

Part no.
Jacket
colour
black
65125
65126
65127
65128
65129
65130
65131
65132
65133

No.cores x AWG-No. Outer Cop.


Weight
cross-sec.
approx. weight approx.
mm
mm
kg/km kg/km
2x3,2
3x3,2
4x3,2
6x3,2
10x3,2
12x3,2
16x3,2
18x3,2
24x3,2

12
12
12
12
12
12
12
12
12

10,0
10,6
11,4
14,4
17,8
18,4
20,6
22,7
26,1

131,4
162,6
221,7
328,1
401,8
460,2
532,3
573,4
626,8

200,0
240,0
300,0
400,0
580,0
800,0
900,0
1000,0
1300,0

Dimensions and specifications may be changed without prior notice. (RN02)

N 71
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Command Cable UL (LiYCY-TP) Style 2464/300 V, 80C,


EMC-preferred type


Technical data

Cable structure

Properties

Special PVC command cable, approved to


UL-Style2464,cores according,
UL-Style1061/1729
Temperature range
flexing -10 C to +80 C
fixed installation -20 C to +80 C
Nominal voltage 300 V
Test voltage 1500 V
Breakdown voltage
min. 3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
fixed approx. 7,5 cable
flexing approx. 15 cable
Coupling resistance
max. 250 Ohm/km

Tinned copper, fine wire conductors to


ASTM-B174-95 classJ-M
Conductor make-up to
0,14 mm = 7x0,162mm
0,23 mm = 7x0,202mm
0,34 mm = 7x0,254mm
0,56 mm = 7x0,32mm
Special PVC core insulation class43,
semirigid to UL-Std.1581 table50.182
and50183
Colour coded to DIN47100 with colour
repetition from pair no.22 and above or
international colour code
Cores stranded in pains with optimal
lay-length
Pains stranded in layers with optimal
lay-length
Seperator-foil
Drain wire
Tinned copper wire braiding, approx.85%
coverage
Special PVC outer jacket class43 to
UL-Std.1581 table50.182
Outer jacket colour
black (international colour code)
grey (DIN 47100 / preferred type from
stock)

PVC flame retardant according to UL


VW-1/CSA FT1
Conditionally resistant to
Oil
Solvents
Acids
Lyes
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
non-screened analogue type:
Command Cable UL (LiYY-TP),
see page N 67

Application
Twisted pair control cable for use in tool making machinery conveyor system and production lines, in industrial plants and in air conditioning
as well as in the steel producing industries.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
Jacket Jacket
colour colour
grey
black
83774
65314
83775
65315
83776
65316
83777
65317
83778
65318
83779
65319
83780
65320
83781
65321
83782
65322
83783
65323
83784
65324
83785
65325
83786
65326
83787
65327
83788
65328
83789
65329
83790
65330
83791
65331

No.pairs x
cross-sec.
mm
1 x 2 x 0,14
2 x 2 x 0,14
3 x 2 x 0,14
4 x 2 x 0,14
5 x 2 x 0,14
6 x 2 x 0,14
7 x 2 x 0,14
8 x 2 x 0,14
10 x 2 x 0,14
12 x 2 x 0,14
14 x 2 x 0,14
15 x 2 x 0,14
16 x 2 x 0,14
18 x 2 x 0,14
20 x 2 x 0,14
22 x 2 x 0,14
24 x 2 x 0,14
25 x 2 x 0,14

AWG-No. Outer Cop.


Weight
approx. weight approx.
mm
kg/km kg/km
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26

4,0
5,6
5,8
6,3
6,7
7,3
7,3
7,8
9,1
9,8
10,5
11,1
11,1
11,8
12,4
13,1
13,6
15,1

15,7
19,5
23,7
26,9
31,2
49,7
52,0
53,9
59,6
67,1
75,2
77,3
80,4
84,2
98,2
104,1
112,0
114,4

32,0
39,0
47,0
55,0
68,0
86,0
92,0
97,0
111,0
141,0
150,0
154,0
155,0
170,0
183,0
207,0
228,0
239,0


Part no.
Jacket Jacket
colour colour
grey
black
83792
65332
83793
65333
83794
65334
83795
65335
83796
65336
83797
65337
83798
65338
83799
65339
83800
65340
83801
65341
83802
65342
83803
65343
83804
65344
83805
65345
83806
65346
83807
65347
83808
65348
83809
65349

No.pairs x
cross-sec.
mm
1 x 2 x 0,23
2 x 2 x 0,23
3 x 2 x 0,23
4 x 2 x 0,23
5 x 2 x 0,23
6 x 2 x 0,23
7 x 2 x 0,23
8 x 2 x 0,23
10 x 2 x 0,23
12 x 2 x 0,23
14 x 2 x 0,23
15 x 2 x 0,23
16 x 2 x 0,23
18 x 2 x 0,23
20 x 2 x 0,23
22 x 2 x 0,23
24 x 2 x 0,23
25 x 2 x 0,23

AWG-No. Outer Cop.


Weight
approx. weight approx.
mm
kg/km kg/km
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24

4,2
5,9
6,2
6,7
7,2
7,7
7,7
8,4
9,9
10,2
10,9
11,4
11,4
12,2
12,7
13,5
14,5
14,8

16,4
27,4
31,7
37,4
54,7
65,6
60,2
74,1
109,3
115,8
120,7
132,4
141,6
146,6
160,6
170,8
229,7
231,4

46,0
53,0
65,0
79,0
98,0
114,0
121,0
129,0
152,0
189,0
213,0
225,0
227,0
238,0
270,0
300,0
321,0
340,0

Continuation

N 72
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Command Cable UL (LiYCY-TP) Style 2464/300 V, 80C,


EMC-preferred type

Part no.
Jacket Jacket
colour colour
grey
black
83810
65350
83811
65351
83812
65352
83813
65353
83814
65354
83815
65355
83816
65356
83817
65357
83818
65358
83819
65359
83820
65360
83821
65361
83822
65362
83823
65363
83824
65364
83825
65365
83826
65366
83827
65367

No.pairs x
cross-sec.
mm
1 x 2 x 0,34
2 x 2 x 0,34
3 x 2 x 0,34
4 x 2 x 0,34
5 x 2 x 0,34
6 x 2 x 0,34
7 x 2 x 0,34
8 x 2 x 0,34
10 x 2 x 0,34
12 x 2 x 0,34
14 x 2 x 0,34
15 x 2 x 0,34
16 x 2 x 0,34
18 x 2 x 0,34
20 x 2 x 0,34
22 x 2 x 0,34
24 x 2 x 0,34
25 x 2 x 0,34

AWG-No. Outer Cop.


Weight
approx. weight approx.
mm
kg/km kg/km
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22

4,6
6,4
6,9
7,5
8,1
8,8
8,8
9,7
11,5
12,0
12,6
13,4
13,4
14,4
15,0
15,9
17,0
17,3

17,0
36,7
44,6
54,1
63,4
73,4
79,4
88,4
107,0
122,4
138,2
154,3
161,4
197,9
211,4
217,6
230,4
138,5

58,0
65,0
78,0
88,0
110,0
126,0
140,0
148,0
184,0
210,0
241,0
245,0
251,0
275,0
300,0
320,0
371,0
402,0


Part no.
Jacket Jacket
colour colour
grey
black
83828
65368
83829
65369
83830
65370
83831
65371
83832
65372
83833
65373
83834
65374
83835
65375
83836
65376
83837
65377
83838
65378
83839
65379
83840
65380
83841
65381
83842
65382
83843
65383
83844
65384
83845
65385

No.pairs x
cross-sec.
mm
1 x 2 x 0,56
2 x 2 x 0,56
3 x 2 x 0,56
4 x 2 x 0,56
5 x 2 x 0,56
6 x 2 x 0,56
7 x 2 x 0,56
8 x 2 x 0,56
10 x 2 x 0,56
12 x 2 x 0,56
14 x 2 x 0,56
15 x 2 x 0,56
16 x 2 x 0,56
18 x 2 x 0,56
20 x 2 x 0,56
22 x 2 x 0,56
24 x 2 x 0,56
25 x 2 x 0,56

AWG-No. Outer Cop.


Weight
approx. weight approx.
mm
kg/km kg/km
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

5,0
7,0
7,6
8,3
9,1
10,1
10,1
12,7
13,2
13,6
14,4
15,5
15,5
16,3
17,1
18,0
19,4
19,8

26,0
56,1
71,7
92,4
107,4
122,4
131,7
144,3
179,6
201,7
221,4
231,6
257,1
282,4
306,7
321,8
342,4
361,2

70,0
89,0
102,0
119,0
140,0
162,0
198,0
272,0
307,0
318,0
342,0
381,0
417,0
494,0
570,0
643,0
724,0
740,0

Dimensions and specifications may be changed without prior notice. (RN02)

Insulating, shrinking, braided and


temperature protection tubes
Braided hoses
High temperature protection
Insulation tubes
Heat-shrink tubes
End caps

You can nd insulating, shrinking, braided and temperature protection tubes


in our catalogue Cable Accessories.

N 73
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N
SiHF UL/CSA
SiHF-C-Si UL/CSA
Photo: HELUKABEL

UL/CSA Heat resistant Cables

N 74
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SiHF UL/CSA halogen-free, 150C/ 600 V, two-approvals silicon multicore


cable


Technical data

Cable structure

Special silicone multicore cable with higher


heat-resistance range to ULStyle4476 and
CSAAWMIIA/B
Temperature range
VDE -60 C to +180 C
(up to +220 C for short time)
UL/CSA -50 C to +150 C
Nominal voltage
VDE U0/U 300/500 V
UL/CSA U 600 V
Test voltage 2000 V
Breakdown voltage min. 5000 V
Insulation resistance
min. 200 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 20x106 cJ/kg (up to 20 Mrad)

Tinned copper conductors to DINVDE0295


cl.5, BS6360 cl.5 and IEC60228 cl.5
Silicone core insulation Core identification
to DINVDE0293-308 colour coded or black
cores with continuous white numbers
For 2-cores brown, blue
Cores stranded in layers with optimal
lay-length
Green-yellow earth-core (3 cores and
above)
Outer jacket of silicone
Jacket colour preferably black

Properties

Note
G = with green-yellow earth core;
x = without green-yellow earth core.
screened analogue type:
SiHF-C-Si UL/CSA
screened analogue type:
SiHF-C-Si UL/CSA, see page N 77

Advantages
Hardly changes of dielectric strength and
the insulation resistance also at high
temperatures, high ignition or flash point,
in case of fire, forms an insulating layer of
SiO2
Resistant to
High molecular oils, fats from vegetables
and animals, alcohols, plasticizers and
clophenes, diluted acids, lyes and salt
dissolution, oxidation substances, tropical
influences and weather, lake water, oxygen
and UV
Halogen-free
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Behaviour in fire
no flame propagation
test according to DINVDE0482
part265-2-1/ EN50265-2-1/ IEC60332-1
(equivalent DINVDE0472 part804 test
methodB)
For laying as a fixed installation only in open
or ventilated pipe systems as well as in
ducts. Otherwise the mechanical properties
of the silicon are reduced by the enclosed
air at temperatures exceeding 90 C.

Application
UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. They are heat-resistant
for permanent temperature up to +180 C, for short time operation up to +220 C. The good performance of the environmental resistant
properties means that silicone cables can be used at temperatures down to -60 C. Silicone cables are halogen-free cables and are especially
suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as
well as in ceramic, glass and cement factories.
Due to elastical characteristic of core insulations, these are used as flexible connection cable.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
23214
23215
23216
23217
23218
23219
23220
23221
23222
23223
23224
23225


No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
6G0,5
7G0,5
8G0,5
10G0,5
12G0,5
16G0,5
18G0,5
25G0,5

AWG-No. Outer
approx.
mm
20
7,7
20
8,1
20
8,8
20
9,4
20
10,4
20
10,4
20
10,8
20
12,8
20
13,4
20
13,9
20
14,4
20
16,8

Cop.
weight
kg/km
9,6
14,4
19,2
24,0
28,8
33,6
38,4
48,0
57,6
76,8
86,4
120,0

Weight
approx.
kg/km
73,0
82,0
98,0
120,0
131,0
140,0
183,0
201,0
241,0
269,0
311,0
401,0


Part no.
23226
23227
23228
23229
23230
23231
23232
23233
23234
23235
23236
23237

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
6G1
7G1
8G1
10G1
12G1
16G1
18G1
25G1

AWG-No. Outer
approx.
mm
17
8,2
17
9,0
17
10,0
17
10,6
17
11,4
17
11,4
17
12,4
17
13,2
17
14,4
17
15,7
17
16,6
17
19,1

Cop.
weight
kg/km
19,2
28,2
38,4
48,0
57,6
67,2
76,8
96,0
115,2
153,6
172,8
240,0

Weight
approx.
kg/km
88,0
111,0
130,0
161,0
182,0
198,0
251,0
304,0
343,0
441,0
492,0
617,0
Continuation

N 75
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SiHF UL/CSA halogen-free, 150C/ 600 V, two-approvals silicon multicore


cable

Part no.
23238
23239
23240
23241
23242
23243
23244
23245
23246
23247
23248
23249
23250
23251
23252
23253
23254
23255
23256
23257
23258
23259
23260
23261
23262
23263
23264
23265
23266
23267
23268
23269

No.cores x
cross-sec.
mm
2x1,5
3G1,5
4G1,5
5G1,5
6G1,5
7G1,5
8G1,5
10G1,5
12G1,5
14G1,5
16G1,5
18G1,5
20G1,5
25G1,5
41G1,5
2x2,5
3G2,5
4G2,5
5G2,5
6G2,5
7G2,5
8G2,5
10G2,5
12G2,5
16G2,5
18G2,5
25G2,5
2x4
3G4
4G4
5G4
7G4

AWG-No. Outer
approx.
mm
16
9,1
16
9,6
16
10,6
16
11,4
16
12,4
16
12,4
16
13,9
16
16,1
16
16,6
16
18,0
16
20,0
16
20,9
16
21,8
16
24,0
16
29,2
14
9,8
14
10,4
14
11,6
14
12,4
14
13,6
14
13,6
14
14,9
14
17,2
14
21,0
14
22,6
14
24,0
14
28,8
12
10,9
12
11,8
12
12,9
12
14,5
12
17,8

Cop.
weight
kg/km
28,8
43,2
57,6
72,0
86,4
100,8
115,2
144,0
172,6
201,6
230,4
259,2
288,0
345,6
590,4
48,0
72,0
96,0
120,0
144,0
168,0
192,0
240,0
288,0
384,0
432,0
600,0
76,8
115,2
153,6
192,0
268,8

Weight
approx.
kg/km
117,0
131,0
166,0
198,0
240,0
261,0
298,0
359,0
431,0
520,0
569,0
652,0
724,0
925,0
1440,0
141,0
174,0
217,0
271,0
314,0
331,0
404,0
495,0
554,0
725,0
838,0
1108,0
190,0
241,0
304,0
384,0
527,0


Part no.
23270
23271
23272
23273
23274
23275
23276
23277
23278
23279
23280
23281
23282
23283
23284
23285
23286
23287
23288
23289
23290

No.cores x
cross-sec.
mm
2x6
3G6
4G6
5G6
7G6
2x10
3G10
4G10
5G10
7G10
2x16
3G16
4G16
5G16
7G16
2x25
3G25
4G25
2x35
3G35
4G35

AWG-No. Outer
approx.
mm
10
14,4
10
15,1
10
16,4
10
18,2
10
21,1
8
18,0
8
18,9
8
20,0
8
22,1
8
24,9
6
20,9
6
22,8
6
24,9
6
26,9
6
28,1
4
25,1
4
27,0
4
32,1
2
28,7
2
30,6
2
32,9

Cop.
weight
kg/km
115,2
172,8
230,4
288,0
403,2
192,0
288,0
384,0
480,0
672,0
307,2
460,8
614,4
768,0
1075,3
480,0
720,0
960,0
672,0
1008,0
1344,0

Weight
approx.
kg/km
284,0
392,0
492,0
610,0
681,0
405,0
620,0
741,0
914,0
1164,0
441,0
501,0
623,0
971,0
1690,0
711,0
1210,0
1524,0
1140,0
1523,0
2217,0

Dimensions and specifications may be changed without prior notice. (RN03)

N 76
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SiHF-C-Si UL/CSA halogen-free, 150C/ 600 V, two-approvals silicon


multicore cable, Cu-screened, EMC-preferred type


Technical data

Cable structure

Properties

Special silicone multicore cable with higher


heat-resistance range to ULStyle4476 and
CSAAWMIIA/B
Temperature range
VDE -60 C to +180 C
(up to +220 C for short time)
UL/CSA -50 C to +150 C
Nominal voltage
VDE: U0/U 300/500 V
UL/CSA: U 600 V
Test voltage 2000 V
Breakdown voltage min. 5000 V
Insulation resistance
min. 200 MOhm x km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 20x106 cJ/kg (up to 20 Mrad)

Tinned copper conductors to DINVDE0295


cl.5, BS6360 cl.5 and IEC60228 cl.5
Silicone core insulation
Core identification to DINVDE0293-308
colour coded or black cores with
continuous white numbers
For 2-cores brown, blue
Cores stranded in layers with optimal
lay-length
Green-yellow earth-core (3 cores and
above)
Foil separator
Tinned copper braided screening, approx.
85% coverage
Outer jacket of silicone
Jacket colour preferably black

Halogen-free
according to VDE0482 part267/
DINEN50267-2-1/ IEC60754-1 (equivalent
DINVDE0472 part815)
Behaviour in fire
no flame propagation
test according to VDE 0482-332-1-2, DIN
EN 60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)

Advantages
Hardly changes of dielectric strength and
the insulation resistance also at high
temperatures
High ignition or flash point
In case of fire, forms an insulating layer of
SiO2
Resistant to
High molecular oils, fats from vegetables
and animals, alcohols, plasticizers and
clophenes, diluted acids, lyes and salt
dissolution, oxidation substances, tropical
influences and weather, lake water, oxygen
and UV
For laying as a fixed installation only in open
or ventilated pipe systems as well as in
ducts. Otherwise the mechanical properties
of the silicon are reduced by the enclosed
air at temperatures exceeding 90 C.


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
non-screened analogue type:
SiHF UL/CSA, see page N 75
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance
of the environmental resistant properties means that silicone cables can be used at temperatures down to -60 C. Silicone cables are
halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing
industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations,
these are used as flexible connection cable.
An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone
multicore flexible cable for such applications as given above.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
22637
22638
22639
22640
22641
22642
22643
22644
22645
22646
22647
22648
22649
22650
22651
22652
22653
22654
22655

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
10G0,5
12G0,5
2x1
3G1
4G1
5G1
7G1
10G1
12G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5

AWG-No. Outer
approx.
mm
20
9,0
20
9,3
20
9,7
20
10,1
20
10,5
20
13,2
20
13,4
17
9,5
17
9,6
17
10,6
17
11,6
17
12,1
17
14,7
17
15,1
16
10,6
16
11,0
16
11,6
16
13,1
16
14,1

Cop.
weight
kg/km
55,5
60,8
66,5
81,6
92,2
124,0
134,4
66,7
86,2
96,8
108,3
141,2
190,0
209,8
87,7
103,5
131,7
148,5
193,4

Weight
approx.
kg/km
94,0
104,0
125,0
149,0
168,0
237,0
260,0
130,0
151,0
169,0
198,0
236,0
248,0
364,0
169,0
191,0
230,0
272,0
341,0


Part no.
22656
22657
22658
22659
22660
22661
22662
22663
22664
22665
22666
22667

No.cores x
cross-sec.
mm
10G1,5
12G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
4G4
5G4
4G6
5G6
4G10

AWG-No. Outer
approx.
mm
16
17,3
16
17,9
14
12,0
14
12,7
14
14,0
14
15,1
14
16,9
12
17,0
12
19,1
10
18,6
10
21,3
8
25,5

Cop.
weight
kg/km
268,5
298,4
122,3
147,7
188,6
214,9
265,7
294,0
374,0
449,0
563,0
759,0

Weight
approx.
kg/km
478,0
521,0
226,0
271,0
332,0
384,0
478,0
516,0
641,0
773,0
980,0
1284,0

Dimensions and specifications may be changed without prior notice. (RN03)

N 77
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N
Rubber-/Neoprene Control Cable
N07RN-F/SOOW
Photo: HELUKABEL

UL/CSA Rubber Cables

N 78
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Rubber / Neoprene Control Cable TypenSJOundSO




Technical data

Cable structure

UL+CSA approved rubber/neoprene flexible


cables
Temperature range
SJO and SO -40 C to +90 C
Nominal voltage
300 V for SJO
600 V for SO
Approvals
UL Subject 62
CSA-C22.2-49

Properties

Plain copper conductors to ASTMB-174


Core insulation of synthetic rubber, EPDM
Cores colour coded
Cores stranded in layers with optimal
lay-length
Hemp or cotton tape
Outer jacket neoprene (oil resistant)
Jacket colour black

Resistant
Oil
Wetness
UV-radiation
Colour code
2 cores black, white
3 cores black, white, green
4 cores black, white, green, red


Note

Note: SJO-18/2
18 = AWG 18
2 = No. of cores
Supply lengths are on original reels of 76
m or 152 m or on drums of 305 m lengths.
Further Types also available: PVC control
cables SJT, SJTO, ST, STO.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.


Application
For use as a feeder cable under rough conditions in motors and machine construction, at shipyards, in steel production and in farming.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Nominal voltage 300 Volt, type SJO (90C)


Part no.

No.cores
x AWG-no.

63010
63011
63012
63013
63014
63015
63016
63017
63018

2 x 18
3 x 18
4 x 18
2 x 16
3 x 16
4 x 16
2 x 14
3 x 14
4 x 14

Current
carrying
capacity
inAmp.
7
7
7
10
10
10
15
15
15

Cond. make-up
n x wire
16 x 0,3
16 x 0,3
16 x 0,3
26 x 0,3
26 x 0,3
26 x 0,3
41 x 0,3
41 x 0,3
41 x 0,3

Outer
approx. mm
7,8
8,4
9,2
8,3
9,0
10,0
9,4
10,0
10,7

Weight
approx. kg/km
65,0
80,0
95,0
130,0
148,0
180,0
195,0
225,0
288,0

Nominal voltage 600 Volt, type SO (90C)


Part no.

No.cores
x AWG-no.

63034
63035
63036
63037
63038
63039
63040
63041
63042
63043
63044
63045
63046
63047
63048

2 x 18
3 x 18
4 x 18
2 x 16
3 x 16
4 x 16
2 x 14
3 x 14
4 x 14
2 x 12
3 x 12
4 x 12
2 x 10
3 x 10
4 x 10

Current
carrying
capacity
inAmp.
7
7
7
10
10
10
15
15
15
20
20
20
25
25
25

Cond. make-up
n x wire
16 x 0,3
16 x 0,3
16 x 0,3
26 x 0,3
26 x 0,3
26 x 0,3
41 x 0,3
41 x 0,3
41 x 0,3
65 x 0,3
65 x 0,3
65 x 0,3
105 x 0,3
105 x 0,3
105 x 0,3

Outer
approx. mm
10,0
10,4
11,0
10,4
11,0
12,3
13,5
14,3
15,3
15,3
16,2
18,9
16,4
17,5
19,0

Weight
approx. kg/km
70,0
86,0
110,0
140,0
155,0
200,0
200,0
235,0
300,0
280,0
310,0
330,0
305,0
325,0
365,0

Dimensions and specifications may be changed without prior notice. (RN04)

N 79
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

H07RN-F/SOOW rubber-sheathed cable, harmonizised type




Technical data

Cable structure

Properties

Rubber-sheated cable H07RN-F according


to VDE 0282 Part 4, HD 22.4 S4
UL - SOOW
CSA - SOOW
Temperature range
HAR -25 C to +60 C
UL/CSA -40 Cto +90 C
Permissible operating temperature
at the conductor +60 C
Nominal voltage
HAR 450/750 V
UL/CSA 600 V
Test voltage 2500 V
Minimum bending radius
Flexing 10x cable
Fixed installation 7,5 cable


Bare copper conductor, fine wire stranded


according to
DIN VDE 0295 cl. 5, BS 6360 cl. 5, IEC 60228
or
HD 383
Rubber core insulation (EPR)
Core identification
3 cores: blue, brown, green-yellow
4 cores: brown, black, grey, green-yellow
5 cores: blue, brown, black, grey,
green-yellow
Cores stranded in layers with optimal
lay-lengths
Rubber outer sheath (CPE)
Sheath colour - black

Ozone-resistant
Weather and UV-resistant
Resistant to oils and greases


Note

G - with green-yellow earth core

Application
Highly-standardised, heavy-duty rubber-sheated cable for use in practically all machines destined for export markets, in dry, damp, wet
environments and outdoors. As a feeder to transportable motors or machines, cranes, hoists, hand lamps and drilling machines.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.




Part no.
39025
39026
39027
39028
39029
39030
39031
39032

No.cores x
cross-sec.
mm
3G1
3G1,5
4G1,5
5G1,5
3G2,5
4G2,5
5G2,5
3G4

Outer
Cop.
approx. mm weight
kg/km
9,6
29,0
10,2
43,0
11,4
58,0
13,1
72,0
14,0
72,0
15,1
96,0
16,9
120,0
16,0
115,0

Weight
approx.
kg/km
130,0
165,0
200,0
240,0
235,0
290,0
345,0
320,0

AWG-No.
18
16
16
16
14
14
14
12


Part no.
39033
39034
39035
39036
39037
39038
39039

No.cores x
cross-sec.
mm
4G4
5G4
3G6
4G6
5G6
3G10
4G10

Outer
Cop.
approx. mm weight
kg/km
17,3
154,0
18,7
192,0
17,1
173,0
18,4
230,0
20,1
288,0
22,9
288,0
25,0
384,0

Weight
approx.
kg/km
395,0
485,0
420,0
540,0
650,0
810,0
950,0

AWG-No.
12
12
10
10
10
8
8

Dimensions and specifications may be changed without prior notice. (RF01)

N 80
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 500-PVC UL/CSA


JZ-602 RC*

MULTISPEED 500-C-PVC UL/CSA


JZ-602 RC*-CY
JZ-602 RC*-PUR
MULTIFLEX 512 PUR UL/CSA
MULTISPEED 500-PUR UL/CSA
JZ-602 RC*-C-PUR
MULTIFLEX 512 C-PUR UL/CSA
MULTISPEED 500-C-PUR UL/CSA
MULTISPEED 500-TPE UL/CSA
MULTISPEED 500-C-TPE UL/CSA
SUPERTRONIC-310-PVC
SUPERTRONIC-310-C-PVC
SUPERTRONIC-330 PUR
SUPERTRONIC 330 C-PUR
SUPER-PAAR-TRONIC 340-C-PUR
MULTISPEED TRONIC-PUR
MULTISPEED TRONIC-C-PUR
Photo: HELUKABEL

UL/CSA Cables for Drag Chains

N 81
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 500-PVC UL/CSA high flexible, safety


against high bending in drag chain systems, oil-resistant, low torsion, meter
marking


Technical data

Cable structure

Properties

Special drag chain cables for high


mechanical stress in adapted to
DINVDE0281 part13 and EDINVDE0245
and UL-Std.758 AWM Style21179
Temperature range
flexing -5 C to +80 C
fixed installation -30 C to +80 C
Nominal voltage
VDE U0/U 300/500 V
UL 600 V
Test voltage 3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors,


Unilay with short pitch length
Special TPE core insulation
Black cores with continuous white
numbering
Green-yellow earth core (3 cores and above)
Stranding:
<7 cores: cores stranded in a layer with
optimal lay-length around a filler as per
construction
7 cores: cores stranded with optimal
lay-length to bunch-construction with low
torsion strength, optimal selected short
lay-length around a filler
Special-PVC outer sheath, especially
resistant against fatigue strength, extruded
as filler with pressure
Sheath colour black (RAL 9005)
with meter marking, change-over in 2011

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
VW-1, FT1
Low-adhesion
Ozon and UV resistant 
High property of alternating bending
strength
Long life durabilities due to low
friction-resistance
Better chemical resistance
Oil resistance to DIN EN 60811-2-1
High stability
Higher economical solution
Reduced , results low weight of moving
materials
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
MULTISPEED 500-C-PVC UL/CSA,
see page N 84

Application

UL/CSA approved HELUKABEL MULTISPEED 500-PVC are installed there, where the extreme requirements for the cables are necessary.
Designed for the export-orientated machinery manufacturer, specifically for USA and Canada. The selected materials and lay-up technique
permit these high flexible cables for permanent application in drag chains for long distances, high and slow speed of movements.
These high flexible PVC control cables are suitable for shift- and bending stresses in machines and machine tool constructions. These are
installed in dry, open airand moist rooms with free movement without tensile stress or forced movements.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
24295
24296
24297
24298
24299
24300
24301
24302
24303
24304
24305
24306
24307
24308
24309
24310
24311
24312
24313
24314

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75
36G0,75
42G0,75
3G1
4G1
5G1
7G1

AWG-No. Outer
approx.
mm
20
4,8
20
5,1
20
5,5
20
6,0
20
9,1
20
10,0
20
12,2
20
14,3
19
6,1
19
6,6
19
10,5
19
11,4
19
14,2
19
16,3
19
20,1
19
22,2
18
5,9
18
6,4
18
7,0
18
11,2

Cop.
weight
kg/km
9,6
14,4
19,0
24,0
33,6
58,0
86,0
120,0
29,0
36,0
50,0
86,0
130,0
180,0
259,0
302,0
29,0
38,4
48,0
67,0

Weight
approx.
kg/km
40,0
45,0
57,0
66,0
81,0
133,0
194,0
274,0
63,0
79,0
107,0
169,0
247,0
366,0
540,0
630,0
69,0
86,0
101,0
140,0


Part no.
24315
24316
24317
24318
24319
24320
24321
24322
24323
24324
24325
24326
24327
24328
24329
24330

No.cores x
cross-sec.
mm
12G1
18G1
25G1
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5

AWG-No. Outer
approx.
mm
18
12,3
18
15,1
18
17,6
16
6,7
16
7,3
16
8,0
16
13,2
16
14,4
16
17,7
16
20,5
14
8,9
14
9,9
14
16,1
14
17,8
14
21,8
14
24,4

Cop.
weight
kg/km
115,0
173,0
240,0
43,0
58,0
72,0
101,0
173,0
259,0
360,0
96,0
120,0
168,0
288,0
432,0
600,0

Weight
approx.
kg/km
227,0
351,0
489,0
88,0
110,0
130,0
182,0
319,0
420,0
604,0
172,0
219,0
303,0
504,0
754,0
940,0

Dimensions and specifications may be changed without prior notice. (RN05)

N 82
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-602 RC* cable for drag chains, 90C, 600V, two approvals control
cable, meter marking


Technical data

Cable structure

Properties

Control cable of special-PVC to UL AWM


Style10012 (core insulation) Style2587
(jacket insulation) and CSA
Temperature range
flexing -5 C to +90 C
fixed installation -40 C to +90 C
Nominal voltage according to UL + CSA
600 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, extra fine wire conductors,


to DINVDE0295 cl.6 col.4, BS6360 cl.6
and IEC60228 cl.6
Special PVC core insulation, YI8 to
DINVDE0207 part4 and class43 to
UL-Std.1581
Red cores with continuous white figure
imprint to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
selected lay-lenght
Core wrapping with fleece over each layer
Special PVC outer jacket YM5 to
DINVDE0207 part5, UL-Style2587 and
CSAC22.2 No210
Outer jacket black (RAL 9005)
with meter marking, change-over in 2011

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
UV-resistant
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core.


AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
JZ-602 RC* -CY, see page N 85

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms. These special cables for drag chains are used for permanent flexible applications in machineries, machine tools,
robot technics, for movable automated machinery parts. These cables have shown excellent performance in combination with standard
cable trays.
Interesting for the export-oriented machines and machinery plants.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
RC = Robotics Cable
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
89900
89901
89902
89903
89904
89905
89906
89907
89908
89909
89910
89911
89912
89913
89914
89915
89916
89917
89918
89919
89920
89921
89922
89923
89924
89925

No.cores x
cross-sec.
mm
3G0,5
4G0,5
5G0,5
7G0,5
9G0,5
12G0,5
18G0,5
25G0,5
34G0,5
3G0,75
4G0,75
5G0,75
7G0,75
9G0,75
12G0,75
15G0,75
18G0,75
25G0,75
34G0,75
3G1,5
4G1,5
5G2,5
7G1,5
9G1,5
12G1,5
18G1,5

AWG-No. Outer
approx.
mm
20
6,0
20
6,5
20
7,1
20
8,2
20
10,0
20
10,5
20
12,5
20
15,2
20
17,1
18
6,6
18
7,1
18
7,8
18
9,2
18
11,0
18
11,5
18
13,2
18
14,0
18
17,2
18
19,1
16
7,4
16
8,0
16
8,8
16
10,8
16
12,8
16
13,5
16
16,0

Cop.
weight
kg/km
14,0
19,0
24,0
34,0
43,2
58,2
86,0
120,0
163,0
23,8
31,7
39,6
55,4
71,2
95,0
119,0
142,4
197,8
269,0
44,0
58,0
72,0
101,0
129,7
173,0
260,0

Weight
approx.
kg/km
58,0
69,0
84,0
123,0
177,0
192,0
256,0
358,0
487,0
88,0
101,0
126,0
145,0
168,0
260,0
300,0
360,0
640,0
730,0
94,0
117,0
140,0
186,0
244,0
319,0
451,0


Part no.
89926
89927
89932
89928
89933
89929
89934
89935
89930
89936
89931
89937
89938
89939
89940
89941

No.cores x
cross-sec.
mm
25G1,5
34G1,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
3G4
4G4
5G4
7G4
4G6
4G10
4G16
4G25
4G35

AWG-No. Outer
approx.
mm
16
19,8
16
22,4
14
8,9
14
10,1
14
11,3
14
13,6
14
16,8
12
10,9
12
12,4
12
13,8
12
16,6
10
14,6
8
18,2
6
22,6
4
26,5
2
30,8

Cop.
weight
kg/km
360,0
490,0
72,0
96,0
120,0
168,0
288,0
115,0
154,0
192,0
269,0
231,0
384,0
615,0
960,0
1344,0

Weight
approx.
kg/km
625,0
840,0
150,0
185,0
242,0
293,0
498,0
231,0
298,0
370,0
460,0
430,0
720,0
1060,0
1590,0
2105,0

Dimensions and specifications may be changed without prior notice. (RN05)

N 83
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 500-C-PVC UL/CSA oil resistant,


high flexible, safety against high bending in drag chain systems, low torsion,
screened, EMC-preferred type, meter marking


Technical data

Cable structure

Properties

Special drag chain cables for high


mechanical stress in adapted to
DINVDE0281 part13 and EDINVDE0245
and UL-Std.758 AWM Style21179
Temperature range
flexing -5 C to +80 C
fixed installation -30 C to +80 C
Nominal voltage
VDE U0/U 300/500 V
UL 600 V
Test voltage 3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Coupling resistance
max. 250 Ohm x km
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors,


Unilay with short pitch length
Special TPE core insulation Black cores with
continuous white numbering
Green-yellow earth core (3 cores and above)
Stranding:
<7 cores: cores stranded in a layer with
optimal lay-length around a filler as per
construction
7 cores: cores stranded with optimal
lay-length to bunch-construction with low
torsion strength, optimal selected short
lay-length around a filler
Special-PVC inner sheath YM2 extruded as
filler with pressure grey (RAL 7001)
Tinned copper braided screen, coverage
85% max., with optimal bunch
Special-PVC outer sheath, especially
resistant against fatigue strength
sheath colourblack (RAL 9005)
with meter marking, change-over in 2011

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
VW-1, FT1
Low adhesion
Ozon and UV resistant
High property of alternating bending
strength
Long life durability due to low
friction-resistance
Better chemical resistance
Oil resistance to DIN EN 6081-2-1
High stability
Higher economical solution
Reduced , results low weight of moving
materials
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
MULTISPEED 500-PVC UL/CSA,
see page N 82

Application

For permanent application in drag chains for long distances, high and slow speed of movements.
These high flexible PVC control cables are suitable for shift- and bending stresses in machines and machine tool constructions. These are
installed in dry, moist rooms and in open airwith free movement without tensile stress or forced movements. These screened cables are
particularly suitable for the interference-free transmission in instrumentation and control engineering applications.
For applications which go beyond standard solutions we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
24335
24336
24337
24338
24339
24340
24341
24342
24343
24344
24345
24346
24347
24348
24349
24350
24351

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
9G0,5
12G0,5
18G0,5
25G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75

AWG-No. Outer
approx.
mm
20
6,6
20
6,9
20
7,3
20
7,8
20
11,3
20
11,4
20
12,6
20
15,0
20
17,1
19
6,8
19
7,4
19
8,0
19
8,5
19
12,9
19
14,4
19
17,5
19
19,9

Cop.
weight
kg/km
30,0
36,0
42,0
48,0
64,0
80,0
105,0
137,0
210,0
40,0
48,0
55,0
66,0
85,0
135,0
190,0
275,0

Weight
approx.
kg/km
88,0
101,0
116,0
146,0
181,0
219,0
271,0
374,0
542,0
96,0
111,0
140,0
161,0
227,0
317,0
486,0
651,0


Part no.
24352
24353
24354
24355
24356
24357
24358
24359
24360
24361
24362
24363
24364
24365
24366
24367

No.cores x
cross-sec.
mm
3G1
4G1
5G1
7G1
12G1
18G1
25G1
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
4G2,5
5G2,5

AWG-No. Outer
approx.
mm
18
7,7
18
8,3
18
9,1
18
14,0
18
15,0
18
18,7
18
21,2
16
8,6
16
9,4
16
10,4
16
16,0
16
17,6
16
21,3
16
24,8
14
11,3
14
12,3

Cop.
weight
kg/km
59,0
70,0
84,0
106,0
174,0
240,0
332,0
75,0
90,0
108,0
157,0
240,0
355,0
448,0
134,0
175,0

Weight
approx.
kg/km
131,0
164,0
198,0
252,0
410,0
550,0
756,0
166,0
199,0
229,0
304,0
502,0
709,0
939,0
270,0
335,0

Dimensions and specifications may be changed without prior notice. (RN05)

N 84
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-602 RC*-CY special cable for drag chains, 90C, 600V, two
approvals control cable, EMC-preferred type, meter marking


Technical data

Cable structure

Properties

Control cable of special-PVC to UL AWM


Style10012 (core insulation) Style2587
(jacket insulation) and CSA
Temperature range
flexing -5 C to +90 C
fixed installation -40 C to +90 C
Nominal voltage
according to UL + CSA 600 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min 20 MOhm x km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, extra fine wire conductors,


to DINVDE0295 cl.6 col.4, BS6360 cl.5
and IEC60228 cl.6
Special PVC core insulation, YI8 to
DINVDE0207 part4 and class43 to
UL-Std.1581
Red cores with continuous white figure
imprint to DINVDE0293
Green-yellow earth core in the outer layer
Cores with optimal selected lay-lenght
Core wrapping with fleece over each layer
PVC-inner sheath
Screening: braid coverage ca. 85%
up to 17 mm - layer of tinned copper
wires
>17 mm - tinned copper wire
Special PVC outer jacket YM5 to
DINVDE0207 part5, UL-Style2587 and
CSAC22.2 No210
Outer jacket black (RAL 9005)
with meter marking, change-over in 2011

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
UV-resistant
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core.


AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
JZ-602 RC*, see page N 83


Application
These cable are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms. These special cables for drag chains are used for permanent flexible applications in machineries, machine tools,
robot technics, for movable automated machinery parts. These cables have shown excellent performance in combination with standard
cable trays. The dense screening assures disturbance-free transmission of all signals and impulses. An ideal disturbance-free control cable
for the above applications. Interesting for the export-oriented machines and machinery plants. For applications which go beyond standard
solutions we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please
read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
RC = Robotics Cable.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
89950
89951
89952
89953
89954
89955
89956
89957
89958
89959
89960
89961
89962
89963
89964
89965
89966
89967
89968
89969
89970
89971
89972
89973
89974
89975

No.cores x
cross-sec.
mm
3G0,5
4G0,5
5G0,5
7G0,5
9G0,5
12G0,5
15G0,5
18G0,5
25G0,5
3G0,75
4G0,75
5G0,75
7G0,75
9G0,75
12G0,75
15G0,75
18G0,75
25G0,75
34G0,75
3G1,5
4G1,5
5G1,5
7G1,5
9G1,5
12G1,5
18G1,5

AWG-No. Outer
approx.
mm
20
8,5
20
9,0
20
9,7
20
11,0
20
12,4
20
13,5
20
14,8
20
16,0
20
19,0
18
8,9
18
9,7
18
10,4
18
12,0
18
14,1
18
15,2
18
16,7
18
17,6
18
20,7
18
24,3
16
10,2
16
11,0
16
11,8
16
14,0
16
16,4
16
17,1
16
20,2

Cop.
weight
kg/km
45,0
52,0
68,0
93,0
134,0
163,0
174,0
191,0
223,0
56,0
81,0
90,0
106,0
161,0
175,0
204,0
241,0
342,0
434,0
89,0
97,0
111,0
147,0
193,0
256,0
360,0

Weight
approx.
kg/km
124,0
135,0
153,0
191,0
243,0
322,0
350,0
374,0
436,0
130,0
155,0
181,0
208,0
321,0
341,0
396,0
473,0
650,0
781,0
165,0
192,0
224,0
274,0
340,0
461,0
674,0


Part no.
89976
89977
89984
89978
89985
89979
89986
89980
89987
89981
89988
89982
89983
89989
89990
89991
89992

No.cores x
cross-sec.
mm
25G1,5
34G1,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
3G4
4G4
5G4
7G4
4G6
4G10
4G16
4G25
4G35

AWG-No. Outer
approx.
mm
16
25,2
16
28,1
14
11,8
14
13,2
14
14,2
14
17,4
14
21,0
14
25,4
12
14,0
12
15,9
12
17,7
12
20,9
10
18,3
8
23,2
6
27,6
4
33,1
2
37,8

Cop.
weight
kg/km
544,0
674,0
141,0
170,0
195,0
251,0
368,0
639,0
180,0
232,0
330,0
395,0
316,0
490,0
850,0
1450,0
1890,0

Weight
approx.
kg/km
950,0
1203,0
220,0
270,0
350,0
428,0
730,0
1140,0
296,0
456,0
450,0
737,0
572,0
1012,0
1400,0
2100,0
2550,0

Dimensions and specifications may be changed without prior notice. (RN05)

N 85
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-602 RC*-PUR special cable for drag chains, 80C, 600V,


two approvals control cable, meter marking


Technical data

Cable structure

Properties

Control cable of special-PUR to UL CSA AWM


I/II A/B Style20939 (jacket insulation) and
CSA
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage
according to UL + CSA 600 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, extra fine wire conductors,


to DINVDE0295 cl.6, BS6360 cl.6 and
IEC60228 cl.6
Special PVC core insulation, YI8 to
DINVDE0207 part4 and class43 to
UL-Std.1581
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
selected lay-lenght
Core wrapping with fleece over each layer
Full-polyurethane
outer jacket grey (RAL 7001)
with meter marking, change-over in 2011

Resistant to mineral oils, synthetic oils and


refrigerants, UV-radiation, oxygene, ozon
and hydrolysis. Conditionally resistant to
microbes.
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers.


Note

G = with green-yellow earth core.


AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
JZ-602 RC* -C-PUR, see page N 91

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist, wet rooms and outdoor. These special cables for drag chains are used for permanent flexible applications in machineries, machine
tools, robot technics, for movable automated machinery parts.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
RC = Robotics Cable.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
12630
12631
12632
12633
12634
12635
12636
12637
12638
12639
12640
12641
12642
12643
12644
12645
12646
12647
12648
12649
12650
12651
12652
12653
12654
12655

No.cores x
cross-sec.
mm
3G0,5
4G0,5
5G0,5
7G0,5
9G0,5
12G0,5
18G0,5
25G0,5
34G0,5
3G0,75
4G0,75
5G0,75
7G0,75
9G0,75
12G0,75
15G0,75
18G0,75
25G0,75
34G0,75
3G1,5
4G1,5
5G1,5
7G1,5
9G1,5
12G1,5
18G1,5

AWG-No. Outer
approx.
mm
20
6,0
20
6,5
20
7,1
20
8,2
20
10,0
20
10,5
20
12,5
20
15,2
20
17,1
18
6,6
18
7,1
18
7,8
18
9,2
18
11,0
18
11,5
18
13,2
18
14,0
18
17,2
18
19,1
16
7,4
16
8,0
16
8,8
16
10,8
16
12,8
16
13,5
16
16,0

Cop.
weight
kg/km
14,0
19,0
24,0
34,0
43,2
58,2
86,0
120,0
163,0
23,8
31,7
39,6
55,4
86,4
95,0
119,0
142,4
197,8
269,0
44,0
58,0
72,0
101,0
129,7
173,0
260,0

Weight
approx.
kg/km
58,0
69,0
84,0
123,0
177,0
192,0
256,0
358,0
487,0
88,0
101,0
126,0
145,0
168,0
260,0
300,0
360,0
640,0
730,0
94,0
117,0
140,0
186,0
244,0
319,0
451,0


Part no.
12656
12657
12658
12659
12660
12661
12662
12663
12664
12665
12666
12667
12668
12669
12670
12671

No.cores x
cross-sec.
mm
25G1,5
34G1,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
3G4
4G4
5G4
7G4
4G6
4G10
4G16
4G25
4G35

AWG-No. Outer
approx.
mm
16
19,8
16
22,4
14
8,9
14
10,1
14
11,3
14
13,6
14
16,8
12
10,9
12
12,4
12
13,8
12
16,6
10
14,6
8
18,2
6
22,6
4
26,5
2
30,8

Cop.
weight
kg/km
360,0
490,0
72,0
96,0
120,0
168,0
288,0
115,0
154,0
192,0
269,0
231,0
384,0
615,0
960,0
1344,0

Weight
approx.
kg/km
625,0
840,0
150,0
185,0
242,0
293,0
498,0
231,0
298,0
370,0
460,0
430,0
720,0
1060,0
1590,0
2105,0

Dimensions and specifications may be changed without prior notice. (RN05)

N 86
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTIFLEX 512-PUR UL/CSA special cable for drag


chains, 80C, 600V, two approvals control cable, halogen-free


Technical data

Cable structure

Properties

Special drag chain cables for high


mechanical stress, according to UL -Style
20939
Temperature range
flexing -40 C to +80 C
fixed installation -50 C to +80 C
Nominal voltage UL/CSA 600 V
Test voltage
3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing 5x cable
fixed installation 3x cable
Alternating bending cycles
approx. 10 million
Radiation resistance
up to 50x106 cJ/kg (up to 50 Mrad)

Bare copper, extra fine wire conductors,


bunch stranded to DINVDE0295 cl.6,
col.4, BS6360 cl.6 and IEC60228 cl.6
Special core insulation, modified TPE
Black cores with continuous white
numbering
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
selected lay-length
Special core wrapping over each layer (up
to 4 mm without core wrapping over the
outer layer)
Special full-polyurethane outer jacket
TMPU, to DINVDE0282 part10
Colour grey (RAL7001) outer surface mat
with meter marking, change-over in 2011

Very good oil resistant


Guaranteed permanent application in
multi-shift operation under extreme high
bending stress
Adhesion-low
High resistant to mechanical strain
High property of alternating bending
strength
Long life durabilities through low
friction-resistance by using the TPE
insulation
High tensile strength-, abrasion- and
impact resistant at low temperature
Resistant to Weather, Ozone and
UV-radiation, Solvents, acids and alkalis, and
Hydrolysis
PUR-jacket flame retardant according to
VDE 0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
when ordering.
screened analogue type:
MULTIFLEX 512 -C-PUR UL/CSA,
see page N 92

Application

These special UL/CSA cables for drag chains are used for permanent flexible applications in machineries, machine tools, robot technics, for
movable automated machinery parts and multi-shift operation. Those cables are developed according to the newest state of technology
improvement. These high flexible control cables with sliding abilities guaranteed an optimum service life durabilities and also very economic
by using the TPE-core insulation and the PUR-outer jacket. The PUR material is adhesion-low and cut-resistant.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
21559
21560
21561
21562
21563
21564
21565
21566
21567
21568
21569
21570

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
20G0,5
25G0,5
30G0,5
36G0,5
2x0,75

AWG-No. Outer
approx.
mm
20
5,5
20
5,8
20
6,4
20
7,0
20
8,1
20
9,9
20
11,5
20
12,0
20
13,7
20
14,3
20
15,3
18
6,2

Cop.
weight
kg/km
9,6
14,4
19,0
24,0
33,6
58,0
86,0
96,0
120,0
144,0
172,0
14,4

Weight
approx.
kg/km
38,0
46,0
59,0
68,0
88,0
131,0
197,0
260,0
282,0
315,0
374,0
47,0


Part no.
21571
21572
21573
21574
21575
21576
21577
21578
21579
21580

No.cores x
cross-sec.
mm
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
20G0,75
25G0,75
30G0,75
36G0,75

AWG-No. Outer
approx.
mm
18
6,5
18
7,0
18
7,8
18
9,0
18
11,0
18
13,0
18
13,5
18
15,4
18
16,2
18
17,6

Cop.
weight
kg/km
21,6
29,0
36,0
50,0
86,0
130,0
144,0
180,0
216,0
259,0

Weight
approx.
kg/km
58,0
69,0
85,0
118,0
183,0
270,0
290,0
374,0
420,0
498,0

Continuation

N 87
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTIFLEX 512-PUR UL/CSA special cable for drag


chains, 80C, 600V, two approvals control cable, halogen-free

Part no.
21581
21582
21583
21584
21585
21586
21587
21588
21589
21590
21591
21592
21593
21594
21595
21596
21597
21598
21599
21600
21601
21602
21603
21604
21605
21606
21607
21608

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
12G1
18G1
20G1
25G1
30G1
36G1
41G1
50G1
65G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
20G1,5
25G1,5
30G1,5
36G1,5
42G1,5
50G1,5
61G1,5

AWG-No. Outer
approx.
mm
17
6,9
17
7,4
17
8,0
17
8,7
17
10,2
17
12,6
17
14,8
17
15,8
17
18,1
17
18,5
17
20,1
17
22,0
17
24,0
17
27,2
16
7,6
16
8,1
16
8,7
16
9,7
16
11,3
16
13,8
16
16,3
16
17,3
16
19,8
16
20,3
16
22,2
16
24,0
16
26,2
16
28,9

Cop.
weight
kg/km
19,2
29,0
38,0
48,0
67,0
115,0
173,0
192,0
240,0
288,0
346,0
410,0
498,0
650,0
29,0
43,0
58,0
72,0
101,0
173,0
259,0
288,0
360,0
432,0
518,0
628,0
749,0
912,0

Weight
approx.
kg/km
55,0
70,0
86,0
102,0
143,0
225,0
334,0
370,0
460,0
530,0
625,0
779,0
953,0
1205,0
70,0
90,0
106,0
145,0
205,0
320,0
465,0
510,0
650,0
750,0
880,0
1209,0
1449,0
1712,0

Part no.
21609
21610
21611
21612
21613
21614
21615
21616
21617
21618
21619
21620
21621
21622
21623
21624
21625
21626
21627
21628
21629

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
20G2,5
25G2,5
4G4
5G4
7G4
4G6
5G6
7G6
4G10
5G10
7G10
4G16
5G16
7G16

AWG-No. Outer
approx.
mm
14
9,2
14
9,7
14
10,5
14
11,6
14
13,8
14
16,9
14
20,0
14
21,2
14
24,4
12
13,2
12
14,6
12
17,6
10
14,4
10
15,9
10
19,2
8
18,4
8
20,7
8
24,7
6
21,3
6
23,8
6
28,6

Cop.
weight
kg/km
48,0
72,0
96,0
120,0
168,0
288,0
432,0
480,0
600,0
154,0
192,0
79,0
230,0
288,0
403,0
384,0
480,0
672,0
614,0
768,0
1075,0

Weight
approx.
kg/km
115,0
162,0
196,0
230,0
312,0
532,0
762,0
858,0
998,0
283,0
349,0
498,0
432,0
529,0
782,0
685,0
817,0
1023,0
1042,0
1292,0
1709,0

Dimensions and specifications may be changed without prior notice. (RN05)

N 88
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 500-PUR UL/CSA safety against high


bending in drag chain systems, low torsion, halogen-free, meter marking


Technical data

Cable structure

Properties

Special drag chain cables for high


mechanical stress in adapted to
DINVDE0281 part13, DINVDE0282 part10
and EDINVDE0245 and UL-Std.758 AWM
Style20233 and 20939
Temperature range
flexing -30 C to +80 C
fixed installation -50 C to +80 C
Nominal voltage
VDE U0/U 300/500 V
UL 600 V
Test voltage 3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors,


Unilay with short pitch length
Special TPE core insulation
Black cores with continuous white
numbering
Green-yellow earth core (3 cores and above)
Stranding:
<7 cores: cores stranded in a layer with
optimal lay-length around a filler as per
construction
7 cores: cores stranded with optimal
lay-length to bunch-construction with low
torsion strength, optimal selected short
lay-length around a filler
Special-PUR outer sheath, especially
resistant against fatigue strength, extruded
as filler with pressure
Sheath colourblack (RAL 9005)
with meter marking, change-over in 2011

PUR-jacket flame retardant according to


VDE 0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB), VW-1, FT1
low adhesion
halogen-free
Higher economical solution
Reduced , results low weight of moving
materials
Halogen-free
High resistant to mechanical strain
Long life durabilitys due to low
friction-resistance
High tensile strength, abrasion- and impact
resistance at low temperature
Tear resistance
High stability
Oil resistance
Better chemical resistance
UV and ozone resistance
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
MULTISPEED 500-C-PUR UL/CSA,
see page N 94

Application

UL/CSA approved HELUKABEL MULTISPEED 500-PUR are installed there, where the extreme requirements for the cables are necessary. The
selected materials and lay-up technique permit these high flexible cables for permanent application in drag chains for long distances, high
an slow speed of movements. These cables are installed in dry, moist and wet rooms and in open air with free movement without tensile
stress or forced movements. These robust and abrasion resistant special control cables are installed there, where the problems appear for
the application in permanent stresses e.g. in energy drag chains, industry robotics, production lines, automatic control systems and permanent
movable machinery parts for multi-shift operation. These cables are installed everywhere, where high requirements for the flexibility,
abrasion, oxygen and chemical resistance are necessary.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
24370
24371
24372
24373
24374
24375
24376
24377

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5

AWG-No. Outer
approx.
mm
20
4,8
20
5,1
20
5,5
20
6,0
20
9,1
20
10,0
20
12,2
20
14,3

Cop.
weight
kg/km
9,6
14,4
19,0
24,0
33,6
58,0
86,0
120,0

Weight
approx.
kg/km
41,0
48,0
62,0
70,0
88,0
131,0
204,0
266,0


Part no.
24378
24379
24380
24381
24382
24383
24384
24385
24386

No.cores x
cross-sec.
mm
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75
36G0,75
42G0,75

AWG-No. Outer
approx.
mm
19
5,2
19
6,1
19
6,6
19
10,5
19
11,4
19
14,2
19
16,3
19
20,1
19
22,2

Cop.
weight
kg/km
21,6
29,0
36,0
50,0
86,0
130,0
180,0
260,0
302,0

Weight
approx.
kg/km
51,0
68,0
73,0
92,0
170,0
257,0
280,0
411,0
608,0

Continuation

N 89
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 500-PUR UL/CSA safety against high


bending in drag chain systems, low torsion, halogen-free, meter marking

Part no.
24387
24388
24389
24390
24391
24392
24393
24331
24394
24395
24396
24397
24398
24399
24400
24332

No.cores x
cross-sec.
mm
3G1
4G1
5G1
7G1
12G1
18G1
25G1
36G1
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
36G1,5

AWG-No. Outer
approx.
mm
18
5,9
18
6,4
18
7,0
18
11,2
18
12,3
18
15,1
18
17,6
18
21,6
16
6,7
16
7,3
16
8,0
16
13,2
16
14,4
16
17,7
16
20,5
16
25,6

Cop.
weight
kg/km
29,0
38,0
48,0
67,0
115,0
173,0
240,0
346,0
43,0
58,0
72,0
101,0
173,0
259,0
360,0
518,0

Weight
approx.
kg/km
59,0
71,0
84,0
111,0
200,0
286,0
370,0
485,0
81,0
102,0
121,0
164,0
293,0
450,0
631,0
779,0

Part no.
24401
24402
24403
24404
24405
24406

No.cores x
cross-sec.
mm
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5

AWG-No. Outer
approx.
mm
14
8,9
14
9,8
14
16,1
14
17,8
14
21,8
14
24,4

Cop.
weight
kg/km
86,0
120,0
168,0
288,0
432,0
600,0

Weight
approx.
kg/km
173,0
220,0
290,0
504,0
719,0
940,0

Dimensions and specifications may be changed without prior notice. (RN05)

Terminations and straight-through joints


Telephone calbes
Low voltage
Medium voltage
Accessories

You can nd terminations and straight-through joints in our catalogue Cable Accessories.

N 90
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JZ-602 RC*-C-PUR special cable for drag chains, 80C, 600V,


two approvals control cable, EMC-preferred type, meter marking


Technical data

Cable structure

Properties

Control cable of special-PUR to UL CSA AWM


I/II A/B Style20939 (jacket insulation) and
CSA
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage
according to UL+CSA 600 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min 20 MOhm x km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up 100x1066 cJ/kg (up to 100 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, extra fine wire conductors,


to DINVDE0295 cl.6, BS6360 cl.6 and
IEC60228 cl.6
Special PVC core insulation, YI8 to
DINVDE0207 part4 and class43 to
UL-Std.1581
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
Cores with optimal selected lay-lenght
Core wrapping with fleece over each layer
PVC-inner sheath
Screening:
up to 17 mm - layer of tinned copper
wires
>17 mm - tinned copper wire braid
coverage ca. 85%
Full-polyurethane
outer jacket grey (RAL 7001)
with meter marking, change-over in 2011

Resistant to mineral oils, synthetic oils and


refrigerants, UV-radiation, oxygene, ozon
and hydrolysis. Conditionally resistant to
microbes.
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers.


Note

G = with green-yellow earth core.


AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
JZ-602 RC* PUR, see page N 86

Application
These cable are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist, wet rooms and outdoor. These special cables for drag chains are used for permanent flexible applications in machineries, machine
tools, robot technics, for movable automated machinery parts. The dense screening assures disturbance-free transmission of all signals and
impulses. An ideal disturbance-free control cable for the above applications. For applications which go beyond standard solutions we
recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the
instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
RC = Robotics Cable.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
12680
12681
12682
12683
12684
12685
12686
12687
12688
12689
12690
12691
12692
12693
12694
12695
12696
12697
12698
12699
12700
12701
12702
12703
12704
12705

No.cores x
cross-sec.
mm
3G0,5
4G0,5
5G0,5
7G0,5
9G0,5
12G0,5
15G0,5
18G0,5
25G0,5
3G0,75
4G0,75
5G0,75
7G0,75
9G0,75
12G0,75
15G0,75
18G0,75
25G0,75
34G0,75
3G1,5
4G1,5
5G1,5
7G1,5
9G1,5
12G1,5
18G1,5

AWG-No. Outer
approx.
mm
20
8,5
20
9,0
20
9,7
20
11,0
20
12,4
20
13,5
20
14,8
20
16,0
20
19,0
18
8,9
18
9,7
18
10,4
18
12,0
18
14,1
18
15,2
18
16,7
18
17,6
18
20,7
18
24,3
16
10,2
16
11,0
16
11,8
16
14,0
16
16,4
16
17,1
16
20,2

Cop.
weight
kg/km
45,0
52,0
68,0
93,0
134,0
163,0
174,0
191,0
223,0
56,0
81,0
90,0
106,0
161,0
175,0
204,0
241,0
342,0
434,0
89,0
97,0
111,0
147,0
193,0
256,0
360,0

Weight
approx.
kg/km
124,0
135,0
153,0
191,0
243,0
322,0
350,0
374,0
436,0
130,0
155,0
181,0
208,0
321,0
341,0
396,0
473,0
650,0
781,0
165,0
192,0
224,0
274,0
340,0
461,0
674,0


Part no.
12706
12707
12708
12709
12710
12711
12712
12713
12714
12715
12716
12717
12718
12719
12720
12721
12722

No.cores x
cross-sec.
mm
25G1,5
34G1,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
3G4
4G4
5G4
7G4
4G6
4G10
4G16
4G25
4G35

AWG-No. Outer
approx.
mm
16
25,2
16
28,1
14
11,8
14
13,2
14
14,2
14
17,4
14
21,0
14
25,4
12
14,0
12
15,9
12
17,7
12
20,9
10
18,3
8
23,2
6
27,6
4
33,1
2
37,8

Cop.
weight
kg/km
544,0
674,0
141,0
170,0
195,0
251,0
368,0
639,0
180,0
232,0
330,0
395,0
316,0
490,0
850,0
1450,0
1890,0

Weight
approx.
kg/km
950,0
1203,0
220,0
270,0
350,0
428,0
730,0
1140,0
296,0
456,0
450,0
737,0
572,0
1012,0
1400,0
2100,0
2550,0

Dimensions and specifications may be changed without prior notice. (RN05)

N 91
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTIFLEX 512-C-PUR UL/CSA special cable for


drag chains, 80C, 600V, two approvals control cable, EMC-preferred type,
halogen-free, meter marking


Technical data

Cable structure

Properties

Special cables for drag chains with high


degree of resistance to mechanical stress
according to UL -Style -20939
Temperature range
flexing -40 C to +80 C
fixed installation -50 C to +80 C
Nominal voltage UL/CSA 600 V
Test voltage
3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Test of alternating bending cycles
approx. 10 million
Radiation resistance
up to 50x106 cJ/kg (up to 50 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, extra fine wire conductors,


bunch stranded to DINVDE0295 cl.6,
col.4, BS6360 cl.6 and IEC60228 cl.6
Special core insulation, modified TPE
Black cores with continuous white
numbering
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
selected lay-length
Special core wrapping over each layers and
an additional fleece over outer layer
TPE-inner sheath, halogen-free
Wrapping with special tapes
Tinned copper braided screening , approx.
85% coverage
Special core wrapping of fleece (up to 4
mm without core wrapping over the outer
layer
Special full-polyurethane outer jacket
TMPU, to DINVDE0282 part10, appendixA
Colour grey (RAL 7001) outer surface mat
with meter marking, change-over in 2011

Very good oil resistant, test method


according to DIN VDE 0472 part 803
Guaranteed permanent application in
multi-shift operation under extreme high
bending stress
Adhesion-low
High resistant to mechanical strain
High property of alternating bending
strength
Long life durabilities through low
friction-resistance by using the TPE
insulation
High tensile strength-, abrasion- and
impact resistant at low temperature
Resistant to Weather, Ozone and
UV-radiation, Solvents, acids and alkalis,
Hydraulic liquidity and Hydrolysis
PUR-jacket flame retardant according to
VDE 0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Please note the cleanroom qualification
when ordering.
unscreened analogue type:
MULTIFLEX 512 PUR UL/CSA,
see page N 87

Application

The special screened UL/CSA cables for drag chains are mainly applied for impulse transmission to prevent external interference effects and
used for permanent flexible applications in machineries, machine tools, robot technics, for movable automated machinery parts and
multi-shift operation. Those cables are developed according to the newest state of technology improvement. These high flexible control
cables with sliding abilities guaranteed an optimum service life durabilities and also very economic by using the TPE-core insulation and the
PUR-outer jacket which is adhesive-free and cut-resistant.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
21630
21631
21632
21633
21634
21635

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5

AWG-No. Outer
approx.
mm
20
8,3
20
8,5
20
9,0
20
9,7
20
11,1
20
12,7

Cop.
weight
kg/km
30,0
38,0
50,0
65,0
70,0
100,0

Weight
approx.
kg/km
90,0
105,0
124,0
132,0
175,0
250,0


Part no.
21636
21637
21638
21639
21640

No.cores x
cross-sec.
mm
18G0,5
20G0,5
25G0,5
30G0,5
36G0,5

AWG-No. Outer
approx.
mm
20
14,7
20
15,4
20
17,1
20
17,9
20
19,2

Cop.
weight
kg/km
157,0
167,0
240,0
273,0
306,0

Weight
approx.
kg/km
325,0
350,0
450,0
510,0
580,0

Continuation

N 92
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTIFLEX 512-C-PUR UL/CSA special cable for


drag chains, 80C, 600V, two approvals control cable, EMC-preferred type,
halogen-free, meter marking

Part no.
21641
21642
21643
21644
21645
21646
21647
21648
21649
21650
21651
21652
21653
21654
21655
21656
21657
21658
21659
21660
21661
21662
21663
21664
21665
21666
21667
21668
21669
21670
21671
21672
21673

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
20G0,75
25G0,75
30G0,75
36G0,75
2x1
3G1
4G1
5G1
7G1
12G1
18G1
20G1
25G1
30G1
36G1
41G1
50G1
65G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5

AWG-No. Outer
approx.
mm
18
8,8
18
9,3
18
9,7
18
10,5
18
11,9
18
14,2
18
16,3
18
16,9
18
19,2
18
19,7
18
21,2
17
9,7
17
10,0
17
10,8
17
11,7
17
13,4
17
16,0
17
18,5
17
19,4
17
21,7
17
22,5
17
24,3
17
26,1
17
28,4
17
32,2
16
10,2
16
11,0
16
11,6
16
12,6
16
14,5
16
17,4
16
19,9
16
23,7

Cop.
weight
kg/km
39,0
49,0
60,0
70,0
95,0
140,0
220,0
249,0
313,0
470,0
500,0
50,0
60,0
73,0
81,0
114,0
186,0
254,0
322,0
377,0
429,0
516,0
610,0
690,0
852,0
64,0
84,0
99,0
129,0
148,0
279,0
393,0
584,0

Weight
approx.
kg/km
110,0
120,0
148,0
160,0
205,0
308,0
420,0
450,0
579,0
630,0
745,0
120,0
135,0
173,0
187,0
240,0
360,0
498,0
568,0
670,0
774,0
895,0
1032,0
1160,0
1660,0
145,0
168,0
217,0
235,0
325,0
481,0
675,0
927,0

Part no.
21674
21675
21676
21677
21678
21679
21680
21681
21682
21683
21684
21685
21686
21687
21688
21689
21690
21691
21692
21693
21694
21695
21696
21697
21698
21699

No.cores x
cross-sec.
mm
30G1,5
36G1,5
42G1,5
50G1,5
61G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
20G2,5
25G2,5
4G4
5G4
7G4
4G6
5G6
7G6
4G10
5G10
7G10
4G16
5G16
7G16

AWG-No. Outer
approx.
mm
16
24,6
16
26,4
16
28,4
16
31,2
16
34,2
14
11,9
14
12,6
14
13,6
14
14,7
14
17,4
14
20,9
14
24,2
14
25,6
14
29,1
12
16,8
12
18,4
12
21,6
10
18,1
10
19,6
10
23,2
8
22,5
8
24,7
8
29,3
6
25,7
6
28,2
6
33,6

Cop.
weight
kg/km
607,0
702,0
829,0
1025,0
1190,0
104,0
140,0
164,0
190,0
236,0
390,0
607,0
661,0
796,0
222,0
328,0
360,0
305,0
441,0
505,0
485,0
610,0
820,0
840,0
1050,0
1510,0

Weight
approx.
kg/km
1025,0
1210,0
1441,0
1709,0
2025,0
198,0
284,0
378,0
423,0
486,0
756,0
1127,0
1210,0
1530,0
448,0
533,0
678,0
636,0
772,0
1028,0
1052,0
1096,0
1530,0
1386,0
1759,0
2087,0

Dimensions and specifications may be changed without prior notice. (RN05)

N 93
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 500-C-PUR UL/CSA safety against


high bending in drag chain systems, low torsion, halogen-free, EMC-preferred
type, meter marking


Technical data

Cable structure

Properties

Special drag chain cables for high


mechanical stress in adapted to
DINVDE0281 part13, DINVDE0282 part10
and EDINVDE0245 and UL-Std.758 AWM
Style20939
Temperature range
flexing -30 C to +80 C
fixed installation -50 C to +80 C
Nominal voltage
VDE U0/U 300/500 V
UL 600 V
Test voltage 3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Coupling resistant
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors,


Unilay with short pitch length
Special TPE core insulation
Black cores with continuous white
numbering
Green-yellow earth core (3 cores and above)
Stranding:
<7 cores: cores stranded in a layer with
optimal lay-length around a filler as per
construction
7 cores: cores stranded with optimal
lay-length to bunch-construction with low
torsion strength, optimal selected short
lay-length around a filler
Special-TPE-O inner sheath, extruded as
filler with pressure, grey RAL7001
Tinned copper braided screen, coverage
85% max., with optimal pitch
Special-PUR outer sheath
Sheath colour black (RAL 9005)
with meter marking, change-over in 2011


PUR-jacket flame retardant according to


VDE 0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB), VW-1, FT1
Low adhesion
High resistant to mechanical strain
Long life durabilitys due to low
friction-resistance
High tensile strength, abrasion- and impact
resistance at low temperature
Tear resistance
High stability
Oil resistance
Better chemical resistance
UV and ozone resistance
Higher economical solution
Reduced , results low weight of moving
materials
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers.



Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
MULTISPEED 500-PUR UL/CSA,
see page N 89

Application

UL/CSA approved HELUKABEL MULTISPEED 500-C-PUR are installed there, where the extreme requirements for the cables are necessary.
Designed for the export-orientated machinery manufacturer, specifically for USA and Canada. The selected materials and lay-up technique
permit these high flexible cables for permanent application in drag chains for long distances, high an slow speed of movements. These
cables are installed in dry, moist and wet rooms and in open air with free movement without tensile stress or forced movements.
These robust and abrasion resistant special control cables are installed there, where the problems appear for the application in permanent
stresses e.g. in energy drag chains, industry robotics, production lines, automatic control systems and permanent movable machinery parts
for multi-shift operation. These cables are installed everywhere, where high requirements for the flexibility, abrasion, oxygen and chemical
resistance are necessary.
These screened cables are particularly suitable for the interference-free transmission in instrumentation and control engineering applications.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
24410
24411
24412
24413
24414
24415
24416
24417
24418

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
9G0,5
12G0,5
18G0,5
25G0,5

AWG-No. Outer
approx.
mm
20
6,6
20
6,9
20
7,3
20
7,8
20
11,3
20
11,4
20
12,6
20
15,0
20
17,5

Cop.
weight
kg/km
30,0
36,0
42,0
48,0
64,0
80,0
105,0
137,0
210,0

Weight
approx.
kg/km
90,0
104,0
118,0
148,0
184,0
219,0
276,0
378,0
547,0


Part no.
24419
24420
24421
24422
24423
24424
24425
24426

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75

AWG-No. Outer
approx.
mm
19
6,8
19
7,4
19
8,0
19
8,5
19
12,9
19
14,4
19
17,5
19
19,9

Cop.
weight
kg/km
40,0
48,0
55,0
66,0
85,0
135,0
190,0
275,0

Weight
approx.
kg/km
100,0
117,0
143,0
167,0
229,0
319,0
492,0
659,0

Continuation

N 94
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 500-C-PUR UL/CSA safety against


high bending in drag chain systems, low torsion, halogen-free, EMC-preferred
type, meter marking

Part no.
24427
24428
24429
24430
24431
24432
24433
24434
24333
24435

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
12G1
18G1
25G1
36G1
3G1,5

AWG-No. Outer
approx.
mm
18
7,1
18
7,7
18
8,3
18
9,1
18
14,0
18
15,0
18
18,7
18
21,4
18
26,1
16
8,6

Cop.
weight
kg/km
50,0
59,0
70,0
84,0
106,0
174,0
240,0
332,0
436,0
75,0

Weight
approx.
kg/km
120,0
140,0
167,0
201,0
256,0
417,0
557,0
766,0
840,0
170,0

Part no.
24436
24437
24438
24439
24440
24441
24334
24442
24443
24444

No.cores x
cross-sec.
mm
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
36G1,5
4G2,5
5G2,5
7G2,5

AWG-No. Outer
approx.
mm
16
9,4
16
10,4
16
16,0
16
17,6
16
21,3
16
24,8
16
30,3
14
11,3
14
12,3
14
19,9

Cop.
weight
kg/km
90,0
108,0
157,0
240,0
355,0
448,0
592,0
134,0
175,0
229,0

Weight
approx.
kg/km
204,0
236,0
309,0
509,0
718,0
944,0
1070,0
280,0
346,0
410,0

Dimensions and specifications may be changed without prior notice. (RN05)

Bundling, binding, fastening


Plastic helix
Cable tie
Hook and loop cable tie
Mounting block

You can nd bundling, binding, fastening in our catalogue Cable Accessories.

N 95
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 500-TPE UL/CSA high flexible,


safety against high bending in drag chain systems, low torsion, halogen-free,
meter marking


Technical data

Cable structure

Properties

Special drag chain cables for high


mechanical stress in adapted to
DINVDE0281 part13 and EDINVDE0245
and UL-Std.758 AWM Style20841 and
21184
Temperature range
flexing -30 C to +80 C
fixed installation -50 C to +80 C
Nominal voltage
VDE U0/U 300/500 V
UL 600 V
Test voltage 3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing 5x cable
fixed installation 3x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Tinned copper, fine wire conductors,


Unilay with short pitch length
Special TPE core insulation
Black cores with continuous white
numbering
Green-yellow earth core (3 cores and above)
Stranding:
<7 cores: cores stranded in a layer with
optimal lay-length around a filler as per
construction
7 cores: cores stranded with optimal
lay-length to bunch-construction with low
torsion strength, optimal selected short
lay-length around a filler
Special-TPE-O outer sheath, extruded as
filler with pressure
Sheath colour ocean blue (RAL 5020)
with meter marking, change-over in 2011
TPE: The selected tinned copper wire
conductor permits the installation in
aggressive environments as well as
hydrogen sulfide, ammonia and sulfur
dioxide

Microbe-resistance - TPE
Low adhesion
High property of alternating bending
strength
High resistant to mechanical strain
Long life durabilitys due to low
friction-resistance
High tensile strength, abrasion- and impact
resistance at low temperature
Extremely high continuous bending loads
Tear resistance
High stability
Oil resistance
Better chemical resistance
UV and ozone resistance
Higher economical solution
Reduced , results low weight of moving
materials
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
when ordering.
screened analogue type:
MULTISPEED 500-C-TPE UL/CSA,
see page N 98

Application

The selected materials and lay-up technique permit these high flexible cables for permanent application in drag chains for long distances,
high an slow speed of movements. These cables are installed in dry, moist and wet rooms and in open air with free movement without
tensile stress or forced movements. These robust and abrasion resistant special control cables are installed there, where the problems appear
for the application in permanent stresses e.g. in energy drag chains, industry robotics, production lines, automatic control systems and
permanent movable machinery parts for multi-shift operation. These cables are installed everywhere, where high requirements for the
flexibility, abrasion, oxygen and chemical resistance are necessary. For applications which go beyond standard solutions (for example for
composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for our especially developed
enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
24450
24451
24452
24453
24454
24455
24456
24457

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5

AWG-No. Outer
approx.
mm
20
4,7
20
5,0
20
5,4
20
5,8
20
8,9
20
9,8
20
11,9
20
13,9

Cop.
weight
kg/km
9,6
14,4
19,0
24,0
33,6
58,0
86,0
120,0

Weight
approx.
kg/km
42,0
49,0
63,0
70,0
90,0
134,0
209,0
270,0


Part no.
24458
24459
24460
24461
24462
24463
24464
24465
24466
24467

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75
36G0,75
42G0,75

AWG-No. Outer
approx.
mm
19
5,0
19
5,2
19
6,1
19
6,6
19
10,5
19
11,4
19
14,2
19
16,3
19
19,5
19
21,3

Cop.
weight
kg/km
14,4
21,6
29,0
36,0
50,0
86,0
130,0
180,0
260,0
302,0

Weight
approx.
kg/km
47,0
55,0
70,0
74,0
95,0
174,0
261,0
290,0
419,0
614,0

Continuation

N 96
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 500-TPE UL/CSA high flexible,


safety against high bending in drag chain systems, low torsion, halogen-free,
meter marking

Part no.
24468
24469
24470
24471
24472
24473
24474
24475
24476
24477
24478

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
12G1
18G1
25G1
3G1,5
4G1,5
5G1,5

AWG-No. Outer
approx.
mm
18
5,2
18
5,9
18
6,4
18
7,0
18
11,2
18
12,3
18
15,1
18
17,6
16
6,7
16
7,3
16
8,0

Cop.
weight
kg/km
19,2
29,0
38,0
48,0
67,0
115,0
173,0
240,0
43,0
58,0
72,0

Weight
approx.
kg/km
50,0
60,0
74,0
86,0
114,0
210,0
291,0
380,0
84,0
108,0
126,0

Part no.
24479
24480
24481
24482
24483
24484
24485
24486
24487
24488

No.cores x
cross-sec.
mm
7G1,5
12G1,5
18G1,5
25G1,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5

AWG-No. Outer
approx.
mm
16
13,2
16
14,4
16
17,7
16
19,8
14
8,9
14
9,8
14
16,1
14
17,8
14
21,8
14
24,4

Cop.
weight
kg/km
101,0
173,0
259,0
360,0
96,0
120,0
168,0
288,0
432,0
600,0

Weight
approx.
kg/km
169,0
299,0
460,0
640,0
179,0
230,0
294,0
510,0
722,0
950,0

Dimensions and specifications may be changed without prior notice. (RN05)

Marking
Marking rings
Cable marker
Indian pen

You can nd marking in our catalogue Cable Accessories.

N 97
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 500-C-TPE UL/CSA safety


against high bending in drag chain systems, low torsion, halogen-free,
EMC-preferred type, meter marking


Technical data

Cable structure

Properties

Special drag chain cables for high


mechanical stress in adapted to
DINVDE0281 part13 and EDINVDE0245
and UL-Std.758 AWM Style21184
Temperature range
flexing -30 C to +80 C
fixed installation -50 C to +80 C
Nominal voltage U0/U 300/500 V
UL 600 V
Test voltage 3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing 5x cable
fixed installation 3x cable
Coupling resistance
max. 250 Ohm x km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Tinned copper, fine wire conductors,


Unilay with short pitch length
Special TPE core insulation
Black cores with continuous white
numbering
Green-yellow earth core (3 cores and above)
Stranding:
<7 cores: cores stranded in a layer with
optimal lay-length around a filler as per
construction
7 cores: cores stranded with optimal
lay-length to bunch-construction with low
torsion strength, optimal selected short
lay-length around a filler
Special-TPE-O inner sheath, extruded as
filler with pressure, natural colour
Screen of Cu braid tinned, coverage 85%
max., with optimal pitch
Special-TPE-O outer sheath, extruded as
filler with pressure
Sheath colour ocean blue (RAL 5020)
with meter marking, change-over in 2011
TPE: The selected tinned copper wire
conductor and tinned copper wire braid
permit the installation in aggressive
environments as well as hydrogen sulfide,
ammonia and sulfur dioxide.


Microbe-resistance - TPE
High property of alternating bending
strength
High resistant to mechanical strain
Long life durabilitys due to low
friction-resistance
High tensile strength, abrasion- and impact
resistance at low temperature
Extremely high continuous bending loads
Low adhesion
Tear resistance
High stability
Oil resistance
Better chemical resistance
UV and ozone resistance
Higher economical solution
Reduced , results low weight of moving
materials
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers.


Application

Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Please note the cleanroom qualification
when ordering.
unscreened analogue type:
MULTISPEED 500-TPE UL/CSA,
see page N 96

The selected materials and lay-up technique permit these high flexible cables for permanent application in drag chains for long distances,
high and slow speed of movements. These cables are installed in dry, moist and wet rooms and in open air with free movement without
tensile stress or forced movements. These robust and abrasion resistant special control cables are installed there, where the problems appear
for the application in permanent stresses e.g. in energy drag chains, industry robotics, production lines, automatic control systems and
permanent movable machinery parts for multi-shift operation. These cables are installed everywhere, where high requirements for the
flexibility, abrasion, oxygen and chemical resistance are necessary.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
23914
23915
23916
23917
23918
23919
23920
23921
23922

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
10G0,5
12G0,5
18G0,5
25G0,5

AWG-No. Outer
approx.
mm
20
6,4
20
6,7
20
7,3
20
7,7
20
11,3
20
10,1
20
12,4
20
14,7
20
17,1

Cop.
weight
kg/km
30,0
36,0
42,0
48,0
64,0
80,0
105,0
137,0
320,0

Weight
approx.
kg/km
85,0
99,0
107,0
140,0
176,0
204,0
261,0
360,0
530,0


Part no.
23923
23924
23925
23926
23927
23928
23929
23930

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75

AWG-No. Outer
approx.
mm
19
7,0
19
7,4
19
8,0
19
8,5
19
12,9
19
14,4
19
17,2
19
19,9

Cop.
weight
kg/km
40,0
48,0
55,0
66,0
85,0
135,0
190,0
275,0

Weight
approx.
kg/km
97,0
110,0
139,0
160,0
219,0
307,0
490,0
640,0

Continuation

N 98
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 500-C-TPE UL/CSA safety


against high bending in drag chain systems, low torsion, halogen-free,
EMC-preferred type, meter marking

Part no.
23931
23932
23933
23934
23935
23936
23937
23938
23939
23940

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
12G1
18G1
25G1
3G1,5
4G1,5

AWG-No. Outer
approx.
mm
18
7,4
18
7,7
18
8,3
18
9,1
18
14,0
18
15,0
18
18,5
18
21,4
16
8,6
16
9,4

Cop.
weight
kg/km
50,0
59,0
70,0
84,0
106,0
174,0
240,0
332,0
75,0
90,0

Weight
approx.
kg/km
115,0
131,0
160,0
195,0
247,0
411,0
547,0
754,0
160,0
194,0

Part no.
23941
23942
23943
23944
23945
23946
23947
23948
23949

No.cores x
cross-sec.
mm
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5
4G2,5
5G2,5
7G2,5
12G2,5

AWG-No. Outer
approx.
mm
16
10,4
16
16,0
16
17,6
16
21,3
16
24,8
14
11,3
14
12,3
14
14,8
14
21,5

Cop.
weight
kg/km
108,0
157,0
240,0
355,0
448,0
134,0
175,0
229,0
390,0

Weight
approx.
kg/km
220,0
294,0
490,0
704,0
930,0
260,0
330,0
406,0
990,0

Dimensions and specifications may be changed without prior notice. (RN05)

Core end sleeves and cable lugs


Core end sleeves
Solderless terminals
Tubular cable lugs
Compression joints

You can nd core end sleeves and cable lugs in our catalogue Cable Accessories.

N 99
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SUPERTRONIC-310-PVC special cable for drag chains,


meter marking


Technical data

Cable structure

Properties

Special PVC drag chain cable approved to


UL-Style2464
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage 300 V
Test voltage 1500 V
Breakdown voltage
min. 3000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 5x cable
fixed installation 3x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper conductor, fine wire


Unilay with short lay-lengths
PVC core insulation, class43 acc. to
ULstd.1581
Colour coded to DIN47100
Cores stranded in layers with optimal
lay-length
Core wrapping from fleece between the
layers of stranding
PVC outer jacket, oil resistant. TM5 acc. to
DINVDE0281 Part1 or class43 acc. to
ULstd.1581
Sheath colour grey (RAL7001)
with meter marking, change-over in 2011

Low-adhesion
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

Please observe applicable installation


regulations for use in energy supply chains.

Application
A highly-flexible PVC control cable suitable for frequent and fast lifting and bending stresses in machines and tool building, robot systems
and on constantly moving machine components. Long service lives guarantee reliable function and good cost efficiency.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable
trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
Designed for machines intended for export, specifically USA and Canada.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
49885
2x0,14
49886
3x0,14
49887
4x0,14
49888
5x0,14
49889
7x0,14
49890
10x0,14
49891
12x0,14
49892
14x0,14
49893
18x0,14
49894
24x0,14
49895
25x0,14
49896
2x0,25
49897
3x0,25
49898
4x0,25
49899
5x0,25
49900
7x0,25
49901
10x0,25
49902
12x0,25

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
24
24
24
24
24
24
24

Outer
Cop.
approx. mm weight
kg/km
3,7
2,8
3,9
4,1
4,1
5,6
4,5
7,0
5,1
9,8
5,8
14,0
6,0
16,8
6,2
19,6
6,9
25,2
7,8
33,6
8,3
35,0
4,0
5,0
4,2
7,5
4,5
10,0
4,9
12,5
5,6
17,5
6,4
25,0
6,6
30,1

Weight
approx.
kg/km
24,0
26,0
31,0
36,0
50,0
65,0
72,0
78,0
91,0
120,0
125,0
29,0
34,0
40,0
51,0
65,0
85,0
97,0


Part no. No.cores x
cross-sec.
mm
49903
14x0,25
49904
18x0,25
49905
24x0,25
49906
25x0,25
49907
2x0,34
49908
3x0,34
49909
4x0,34
49910
5x0,34
49911
7x0,34
49912
10x0,34
49913
12x0,34
49914
14x0,34
49915
18x0,34
49916
24x0,34
49917
25x0,34

AWG-No.
24
24
24
24
22
22
22
22
22
22
22
22
22
22
22

Outer
Cop.
approx. mm weight
kg/km
6,9
35,0
7,6
45,0
8,8
60,0
9,4
62,5
4,2
6,8
4,4
10,2
4,8
13,6
5,1
17,0
5,9
23,8
6,8
34,0
7,0
40,8
7,4
47,6
8,1
61,2
9,6
81,5
10,0
85,0

Weight
approx.
kg/km
109,0
132,0
171,0
178,0
34,0
43,0
58,0
65,0
85,0
117,0
134,0
152,0
184,0
242,0
252,0

Dimensions and specifications may be changed without prior notice. (RN05)

N 100
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SUPERTRONIC-310-C-PVC special cable for drag chains,


EMC-preferred type, meter marking


Technical data

Cable structure

Properties

Special PVC drag chain cable approved to


UL-Style2464
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage 300 V
Test voltage
core/core 1500 V
core/screen 1000 V
Breakdown voltage
min. 3000 V
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Insulation resistance
min. 20 MOhm x km
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper conductor, fine wire


Unilay with short lay-lengths
PVC core insulation, class43 acc. to
ULstd.1581
Colour coded to DIN 47100
Cores stranded in layers with optimal
lay-length
Core wrapping from fleece between the
layers of stranding
Core wrapping over the outer layer
Braided screen of tinned Cu wires,
coverage approx. 85%
Core wrapping with fleece
PVC outer jacket, oil resistant, TM5 acc. to
DINVDE0281 Part1 or class43 acc. to
ULstd.1581
Sheath colour grey (RAL 7001)
with meter marking, change-over in 2011

Low-adhesion
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

Please observe applicable installation


regulations for use in energy supply chains.

Application
A highly-flexible PVC control cable suitable for frequent and fast lifting and bending stresses in machines and tool building, robot systems
and on constantly moving machine components. Long service lives guarantee reliable function and good cost efficiency. The copper screen
effectively protects against internal and external interference. Designed for machines intended for export, specifically USA and Canada.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable
trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.cores x


cross-sec.
mm
49920
2x0,14
49921
3x0,14
49922
4x0,14
49923
5x0,14
49924
7x0,14
49925
10x0,14
49926
12x0,14
49927
14x0,14
49928
18x0,14
49929
24x0,14
49930
25x0,14
49931
2x0,25
49932
3x0,25
49933
4x0,25
49934
5x0,25
49935
7x0,25
49936
10x0,25
49937
12x0,25

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
24
24
24
24
24
24
24

Outer
Cop.
approx. mm weight
kg/km
4,3
11,3
4,5
14,2
4,7
15,5
5,0
18,4
5,7
27,9
6,4
39,1
6,7
42,2
6,9
45,4
7,6
54,2
8,6
66,5
9,0
68,5
4,6
14,8
4,8
18,9
5,1
21,4
5,5
31,2
6,2
39,8
7,1
53,9
7,3
59,2

Weight
approx.
kg/km
33,0
36,0
41,0
46,0
70,0
88,0
97,0
105,0
116,0
150,0
157,0
39,0
45,0
52,0
70,0
80,0
114,0
123,0


Part no. No.cores x
cross-sec.
mm
49938
14x0,25
49939
18x0,25
49940
24x0,25
49941
25x0,25
49942
2x0,34
49943
3x0,34
49944
4x0,34
49945
5x0,34
49946
7x0,34
49947
10x0,34
49948
12x0,34
49949
14x0,34
49950
18x0,34
49951
24x0,34
49952
25x0,34

AWG-No.
24
24
24
24
22
22
22
22
22
22
22
22
22
22
22

Outer
Cop.
approx. mm weight
kg/km
7,6
64,3
8,3
78,6
9,7
89,8
10,1
101,2
4,8
18,2
5,0
28,8
5,4
35,8
5,7
39,2
6,6
52,8
7,5
67,5
7,7
76,5
8,1
85,9
8,9
99,9
10,3
147,0
10,9
155,0

Weight
approx.
kg/km
138,0
165,0
200,0
204,0
44,0
60,0
76,0
80,0
104,0
150,0
160,0
180,0
211,0
290,0
304,0

Dimensions and specifications may be changed without prior notice. (RN05)

N 101
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SUPERTRONIC-330 PUR cable for drag chains,


halogen-free, meter marking


Technical data

Cable structure

Properties

Special PUR sheathed cable


Temperature range
flexing -40 C to +80 C
fixed -50 C to +80 C
Nominal voltage 300 V
Test voltage
core/core 1500 V
Insulation resistance
min. 100 MOhm x km
Capacitance
core/core 60 nF/km
Minimum bending radius
flexing 5 x cable
fixed 3 x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)


Bare copper, extra fine-wire to


DINVDE0295 cl.6, col.4, BS6360 cl.6
Polyolefine core insulation
Cores stranded in layers with optimally
adjusted lay-lengths
Cores colour coded to DIN47100
Foil wrapping over the outer layer
Special full-polyurethane outer sheath
TMPU to DINVDE0282 Part10, AnnexA
and acc. to ULstd.1581 Tab.50227 80 C
Sheath colour grey (RAL7001)
with meter marking, change-over in 2011

PUR flame retardant according to VDE


0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Low adhesion
High flexibility at low temperatures
High abrasion resistance
Tear and cut-resistant
Notch resistant
Resistant to
UV-radiation, Oxygen, Ozone, Hydrolysis,
Oil
Partially resistant to
Microbial attack, Hydraulic fluids, Coolant
emulsion, Alkalis
The materials used in manufacture are
silicon and cadmium-free and contain no
substances harmful to the wetting
properties of lacquers

Application
For installation in dry, moist and wet rooms and outdoors with free movement without tensile stress or forced movements, impressively
proven in drag chain application.
A highly flexible PUR control cable, suitable for frequent and quick lifting and bending stresses in machine engineering and construction,
in robot technology and on permanently moving machine components. Long service life guarantees reliable function and high cost-efficiency.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable
trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
Attractive for export-oriented mechanical engineering.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
49764
2x0,14
49765
3x0,14
49766
4x0,14
49767
5x0,14
49768
7x0,14
49769
10x0,14
49770
12x0,14
49771
14x0,14
49772
18x0,14
49773
24x0,14
49774
25x0,14
49775
2x0,25
49776
3x0,25
49777
4x0,25
49778
5x0,25
49779
7x0,25
49780
10x0,25
49781
12x0,25

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
24
24
24
24
24
24
24

Outer
Cop.
approx. mm weight
kg/km
3,9
2,8
4,0
4,1
4,3
5,6
4,7
7,0
5,3
9,8
6,1
14,0
6,2
16,8
6,5
19,6
7,2
25,2
8,2
33,6
8,6
35,0
4,3
5,0
4,5
7,5
4,8
10,0
5,2
12,5
6,0
17,5
6,9
25,0
7,1
30,1

Weight
approx.
kg/km
22,0
24,0
29,0
33,0
47,0
57,0
63,0
72,0
80,0
110,0
115,0
26,0
30,0
39,0
44,0
52,0
70,0
84,0


Part no. No.cores x
cross-sec.
mm
49782
14x0,25
49783
18x0,25
49784
24x0,25
49785
25x0,25
49786
2x0,34
49787
3x0,34
49788
4x0,34
49789
5x0,34
49790
7x0,34
49791
10x0,34
49792
12x0,34
49793
14x0,34
49794
18x0,34
49795
24x0,34
49796
25x0,34

AWG-No.
24
24
24
24
22
22
22
22
22
22
22
22
22
22
22

Outer
Cop.
approx. mm weight
kg/km
7,4
35,0
8,2
45,0
9,6
60,0
10,1
62,5
4,6
6,8
4,8
10,2
5,2
13,6
5,6
17,0
6,5
23,8
7,5
34,0
7,7
40,8
8,1
47,6
9,2
61,2
10,7
81,5
11,2
85,0

Weight
approx.
kg/km
97,0
114,0
157,0
160,0
31,0
38,0
51,0
54,0
77,0
104,0
122,0
140,0
162,0
204,0
229,0

Dimensions and specifications may be changed without prior notice. (RN05)

N 102
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SUPERTRONIC-330 C-PUR cable for drag chains,


halogen-free, EMC-preferred type, meter marking


Technical data

Cable structure

Properties

Special PUR sheathed cable, screened


Temperature range
flexing -40 C to +80 C
fixed -50 C to +80 C
Nominal voltage 300 V
Test voltage
core/core 1500 V
core/screen 1000 V
Insulation resistance
min. 100 MOhm x km
Capacitance
core/core 60 nF/km
Minimum bending radius
flexing 7,5 x cable
fixed 4 x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper conductor, extra fine wire to


DINVDE0295 cl.6, col.4, BS6360 cl.6
Polyolefine core insulation
Colour coded to DIN47100
Cores stranded in layers with optimal
lay-length
Wrapping over the outer layer
Braided screen of tinned Cu wires,
coverage approx. 85%
Core wrapping with fleece
Special full polyurethane outer sheath
TMPU acc. to DINVDE0281 Part10,
AnnexA and acc. to ULstd.1581 Tab.50227
80 C
Sheath colour grey (RAL7001)
with meter marking, change-over in 2011

Flame retardant according to VDE


0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Low-adhesion
High flexibility at low temperatures
High abrasion resistance
Tear and cut-resistant
Notch resistant
Resistant to
UV-radiation, Oxygen, Ozone, Hydrolysis,
Oil
Partially resistant to
Microbial attack, Hydraulic fluid, Coolant
emulsion, Alkalis
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Application
Especially suited for drag chain installation in dry, moist and wet environments and outdoors with flexible movement and without tensile
stress or forced movements. A highly-flexible PVC control cable suitable for frequent and fast lifting and bending stresses in machines and
tool building, robot systems and on constantly moving machine components. Long service lives guarantee reliable function and good cost
efficiency. The dense screening assures interference-free transmission of all signals and impulses. An ideal interference-free control cable
for the above applications.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable
trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibility
To optimise the EMC characteristics we recommend a large area of contact of the copper braiding around the entire circumference on both
ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.cores x


cross-sec.
mm
49797
2x0,14
49798
3x0,14
49799
4x0,14
49800
5x0,14
49801
7x0,14
49802
10x0,14
49803
12x0,14
49804
14x0,14
49805
18x0,14
49806
24x0,14
49807
25x0,14
49808
2x0,25
49809
3x0,25
49810
4x0,25
49811
5x0,25
49812
7x0,25
49813
10x0,25
49814
12x0,25

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
24
24
24
24
24
24
24

Outer
Cop.
approx. mm weight
kg/km
4,4
11,2
4,5
14,1
4,8
15,5
5,0
18,3
5,8
27,8
6,7
39,3
6,8
42,1
7,1
45,3
7,8
54,1
8,8
66,3
9,2
68,4
4,8
14,9
5,0
18,8
5,3
21,3
5,7
31,0
6,6
39,6
7,5
53,9
7,7
59,1

Weight
approx.
kg/km
32,0
35,0
40,0
45,0
66,0
86,0
94,0
102,0
118,0
149,0
156,0
38,0
44,0
51,0
68,0
82,0
110,0
124,0


Part no. No.cores x
cross-sec.
mm
49815
14x0,25
49816
18x0,25
49817
24x0,25
49818
25x0,25
49819
2x0,34
49820
3x0,34
49821
4x0,34
49822
5x0,34
49823
7x0,34
49824
10x0,34
49825
12x0,34
49826
14x0,34
49827
18x0,34
49828
24x0,34
49829
25x0,34

AWG-No.
24
24
24
24
22
22
22
22
22
22
22
22
22
22
22

Outer
Cop.
approx. mm weight
kg/km
8,0
64,2
8,8
78,4
10,2
89,9
10,7
101,0
5,1
18,1
5,3
28,7
5,7
35,7
6,1
39,1
7,1
52,7
8,1
67,4
8,3
76,4
8,7
85,5
9,8
99,7
11,3
147,1
11,8
155,0

Weight
approx.
kg/km
135,0
150,0
194,0
204,0
45,0
60,0
76,0
82,0
110,0
148,0
166,0
185,0
216,0
291,0
305,0

Dimensions and specifications may be changed without prior notice. (RN05)

N 103
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SUPER-PAAR-TRONIC 340-C-PUR cable for drag


chains, halogen-free, EMC-preferred type, meter marking


Technical data

Cable structure

Properties

Special drag chain cable, stranded in pairs


Temperature range
flexing -20 C to +80 C
fixed -40 C to +80 C
Nominal voltage 300V
Test voltage
core/core 1500 V
core/screen 1000 V
Insulation resistance
min. 100 MOhm x km
Mutual capacitance
core/core approx. 60 nF/km
Minimum bending radius
for permanent bending
at 0,25 mm
flexing 7,5x cable
fixed 4x cable
at 0,5-1,0 mm
flexing 10x cable
fixed 5x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper conductor, fine or extra


finewire to DINVDE0295 cl.6, col.4,
BS6360 cl.6 and IEC 60228 cl. 6
Polyolefin core insulation
Colour coded to DIN47100
Cores stranded in pairs, pairs stranded
torsion-free in layers with optimal
lay-length
Core wrapping between the layers of
stranding
Braided screen of tinned Cu wires,
coverage approx. 85%
Core wrapping with fleece
Full polyurethane outer sheath TMPU
acc. to DINVDE0281 Part10, AnnexA and
acc. to ULstd.1581 Tab.50227 80 C
Sheath colour grey (RAL7001)
with meter marking, change-over in 2011

Flame retardant according to VDE


0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Oil resistance according to IEC 60092-350
Halogen free
Weather, ozone and UV-resistant
Chemical resistance to solvents, acids,
alkalis and hydraulic fluids
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Advantages
Very high resistance to mechanical stresses
Very good alternating bending strength
High tear, abrasion and impact resistance,
even at low temperatures

Application
Stranded in pairs, these fully-screened special drag chain cables can also be used where external, high-frequency interference influences
pulse transfer. They are used for permanently flexible stresses in machine and tool building, in robot technology, on constantly moving
machine components and for extended use in multi-shift operations.
Developed to state-of-the-art technology, these highly-flexible data cable, with a cut resistant and low-adhesion PUR outer sheath guaranteeing
optimal service life and extremely good cost efficiency. This two-approvals single-core cable is preferred for use in export-oriented mechanical
engineering, in machine tools, production lines and systems engineering. Guaranteed extended use in multi-shift operations with extremely
high bending stresses.
EMC = Electromagnetic compatibility
To optimise the EMC characteristics we recommend a large area of contact of the copper braiding around the entire circumference on both
ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.pairs x
no.cores x
cross-sec.
mm
49830
1x2x0,25
49831
2x2x0,25
49832
3x2x0,25
49833
4x2x0,25
49834
5x2x0,25
49835
6x2x0,25
49836
8x2x0,25
49837
10x2x0,25
49838
14x2x0,25
49839
1x2x0,34
49840
2x2x0,34
49841
3x2x0,34
49842
4x2x0,34
49843
5x2x0,34
49844
6x2x0,34
49845
8x2x0,34
49846
10x2x0,34
49847
14x2x0,34
49848
1x2x0,5
49849
2x2x0,5
49850
3x2x0,5
49851
4x2x0,5
49852
5x2x0,5

AWG-No.

24
24
24
24
24
24
24
24
24
22
22
22
22
22
22
22
22
22
20
20
20
20
20

Outer
Cop.
approx. mm weight
kg/km
4,8
6,7
7,1
7,6
8,3
9,0
10,5
11,9
12,7
5,1
7,2
7,6
8,3
9,0
9,9
11,9
13,9
14,1
5,8
8,4
9,0
10,0
11,0

14,0
32,0
38,4
43,2
51,5
71,8
74,4
90,0
111,2
20,0
41,0
52,2
59,1
67,0
86,4
107,5
131,0
150,0
22,5
53,0
72,8
75,6
85,7

Weight
approx.
kg/km
26,0
61,0
70,0
82,0
99,0
126,0
147,0
179,0
210,0
35,0
80,0
100,0
118,0
134,0
162,0
214,0
270,0
304,0
47,0
100,0
131,0
149,0
169,0


Part no. No.pairs x
no.cores x
cross-sec.
mm
49853
6x2x0,5
49854
8x2x0,5
49855
10x2x0,5
49856
14x2x0,5
49857
1x2x0,75
49858
2x2x0,75
49859
3x2x0,75
49860
4x2x0,75
49861
5x2x0,75
49862
6x2x0,75
49863
8x2x0,75
49864
10x2x0,75
49865
14x2x0,75
49866
1x2x1
49867
2x2x1
49868
3x2x1
49869
4x2x1
49870
5x2x1

AWG-No.

20
20
20
20
19
19
19
19
19
19
19
19
19
18
18
18
18
18

Outer
Cop.
approx. mm weight
kg/km
11,8
14,2
16,5
16,9
6,2
9,2
9,8
11,2
12,2
13,2
15,6
18,4
18,9
6,7
10,0
10,8
11,7
13,2

103,0
148,4
180,0
218,3
35,2
61,4
87,1
95,2
115,0
137,1
184,4
259,8
318,4
42,0
73,0
93,6
117,8
139,0

Weight
approx.
kg/km
181,0
274,0
332,0
390,0
56,0
102,0
144,0
160,0
193,0
216,0
327,0
451,0
521,0
64,0
120,0
160,0
184,0
217,0

Dimensions and specifications may be changed without prior notice. (RN05)

N 104
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED-TRONIC-PUR safety against high bending


in drag chain systems, halogen-free, meter marking


Technical data

Cable structure

Properties

Special drag chain cables for high


mechanical stress in adapted to
DINVDE0281 part13, DINVDE0282 part10
and EDINVDE0245 and UL-Std.758AWM
Style20233 and 20939.
Temperature range
flexing -30 C to +80 C
fixed installation -50 C to +80 C
Nominal voltage U0/U 300/300 V
Test voltage 3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, Unilay


with short pitch length
Special TPE core insulation
Colour coded to DIN 47100
Stranding:
<7 cores: cores stranded in a layer with
optimal lay-length around a filler as per
construction
7 cores: cores stranded with optimal
lay-length to bunch-construction with low
torsion strength, optimal selected short
lay-length around a filler
Special-PUR outer sheath, especially
resistant against fatigue strength, extruded
as filler with pressure, sheath
Colourblack (RAL 9005)
with meter marking, change-over in 2011

PUR flame retardant according to VDE


0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB), VW-1, FT1
Low-adhesion
Halogen-free
High property of alternating bending
strength
High tensile strength, abrasion- and impact
resistance at low temperature
Use in multi-shift operations under
extremely high continuous bending loads
Abrasion resistance
Tear resistance
High stability
Oil resistance
Better chemical resistance
UV and ozone resistance
Higher economical solution
Reduced diameter, therefore lower moving
masses
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

screened analogue type:


MULTISPEED TRONIC-C-PUR,
see page N 106

Application

Application HELUKABEL MULTISPEED-TRONIC-PUR installed there, where the extreme requirements for the cables are necessary. The selected
materials and lay-up technique permit these high flexible cables for permanent application in drag chains for long distances, high and low
speed of movements. These cables are installed in dry, moist and wet rooms and in open air with free movement without tensile stress or
forced movements. These robust and abrasion resistant special control cables are installed there, where the problems appear for the
application in permanent stresses e.g. in energy drag chains, industry robotics, production lines, automatic control systems and permanent
movable machinery parts for multi-shift operation. These cables are installed everywhere, where high requirements for the flexibility,
abrasion, oxygen and chemical resistance are necessary.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
24567
24568
24569
24570
24571
24572
24573
24574

No.cores x
cross-sec.
mm
2x0,25
3x0,25
4x0,25
5x0,25
7x0,25
12x0,25
18x0,25
25x0,25

AWG-No. Outer
approx.
mm
24
3,9
24
4,1
24
4,4
24
4,7
24
6,9
24
7,4
24
8,9
24
10,2

Cop.
weight
kg/km
5,0
7,5
10,0
12,5
17,5
30,1
45,0
62,5

Weight
approx.
kg/km
27,0
33,0
40,0
48,0
60,0
91,0
125,0
170,0


Part no.
24575
24576
24577
24578
24579
24580
24581
24582

No.cores x
cross-sec.
mm
2x0,34
3x0,34
4x0,34
5x0,34
7x0,34
12x0,34
18x0,34
25x0,34

AWG-No. Outer
approx.
mm
22
4,1
22
4,3
22
4,6
22
5,0
22
7,3
22
7,9
22
9,7
22
10,0

Cop.
weight
kg/km
6,8
10,2
13,6
17,0
23,8
40,8
61,2
85,0

Weight
approx.
kg/km
32,0
40,0
55,0
60,0
80,0
127,0
175,0
238,0

Dimensions and specifications may be changed without prior notice. (RN05)

N 105
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED-TRONIC-C-PUR safety against high


bending in drag chain systems, high flexible, halogen-free, screened, EMC-preferred
type, meter marking


Technical data

Cable structure

Properties

Special drag chain cables for high


mechanical stress in adapted to
DINVDE0281 part13, DINVDE0282 part10
and EDINVDE0245 and UL-Std.758 AWM
Style20233 and 20939.
Temperature range
flexing -30 C to +80 C
fixed installation -50 C to +80 C
Nominal voltage U0/U 300/300 V
Test voltage 3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, Unilay


with short pitch length
Special TPE core insulation
Colour coded to DIN 47100
Stranding:
<7 cores: cores stranded in a layer with
optimal lay-length around a filler as per
construction
7 cores: cores stranded with optimal
lay-length to bunch-construction with low
torsion strength, optimal selected short
lay-length around a filler
Special-TPE inner sheath, extruded as filler
with pressure, grey (RAL7001)
Screen of Cu braid bare, coverage 85%
max., with optimal pitch
Special-PUR outer sheath
Sheath colour black (RAL 9005)
with meter marking, change-over in 2011

flame retardant according to VDE


0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB) VW-1, FT1
Low-Adhesion
Halogen-free
High property of alternating bending
strength
High tensile strength, abrasion- and impact
resistance at low temperature
Use in multi-shift operations under
extremely high continuous bending loads
Abrasion resistance
Tear resistance
High stability
Oil resistance
Better chemical resistance
UV and ozone resistance
Higher economical solution
Reduced , results low weight of moving
materials
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

non screened analogue type:


MULTISPEED TRONIC-PUR,
see page N 105

Application

For permanent application in drag chains for long distances, high and low speed of movements. These cables are installed in dry, moist and
wet rooms and in open air with free movement without tensile stress or forced movements. These robust and abrasion resistant special
control cables are installed there, where the problems appear for the application in permanent stresses. These cables are installed everywhere,
where high requirements for the flexibility, abrasion, oxygen and chemical resistance are necessary. These screened cables are particularly
suitable for the interference-free transmission in instrumentation and control engineering applications.
For applications which go beyond standard solutions we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
24614
24615
24616
24617
24618
24619
24620
24621

No.cores x
cross-sec.
mm
2x0,25
3x0,25
4x0,25
5x0,25
7x0,25
12x0,25
18x0,25
25x0,25

AWG-No. Outer
approx.
mm
24
5,4
24
5,6
24
5,9
24
6,2
24
8,7
24
9,4
24
11,5
24
13,0

Cop.
weight
kg/km
74,0
19,0
22,0
26,0
35,0
58,0
79,0
99,0

Weight
approx.
kg/km
39,0
45,0
51,0
68,0
83,0
122,0
160,0
210,0


Part no.
24622
24623
24624
24625
24626
24627
24628
24629

No.cores x
cross-sec.
mm
2x0,34
3x0,34
4x0,34
5x0,34
7x0,34
12x0,34
18x0,34
25x0,34

AWG-No. Outer
approx.
mm
22
5,6
22
5,8
22
6,1
22
6,8
22
9,3
22
9,9
22
12,3
22
13,6

Cop.
weight
kg/km
18,0
22,0
28,0
31,0
51,0
70,0
103,0
130,0

Weight
approx.
kg/km
45,0
60,0
76,0
82,0
110,0
166,0
216,0
312,0

Dimensions and specifications may be changed without prior notice. (RN05)

N 106
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

UL-Style 1007, CSA TR 65


UL-Style 1569, CSA TR 64
UL-Style 1015
DREINORM
FNFNORM
THHN/THWN
PVC-Single Cores
HELUTHERM 145
UL-Style 3135
Single 600-J/-O
Single 600-CY -J/-O
Single 602-RC* -J/O
Single 602-RC*-CY -J/O
MULTISPEED 600-PUR -J/-O
MULTISPEED 600-C-PUR -J/-O
Photo: HELUKABEL

UL/CSA Single Conductors

N 107
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

UL-Style 1007, CSA TR 64 PVC single cores, 80C, 300V




Technical data

Cable structure

PVC-single core toUL-Style and CSA-AWM


UL-Style 1007
CSA-AWM I A/B or TR 64
Temperature range
flexible -5 C bis +80 C
fixed installation -30 C bis +80 C
CSA-AWM I A/B or TR 64 +90 C
Nominal voltage 300 V
Test voltage 2000 V
Test voltage (Spark test)
AWG 26-20 = 4 kV
AWG 10-18 = 5 kV
Bending radius
once approx. 5x core
multiple approx. 10x core

Stranded copper conductor, tinned to


UL-Std.785 sectionG
PVC-core insulation according to
UL-Std.1581 class43 Tab.50.182, heat and
damp resistant


Properties

Conditionally resistant to
Oils
Solvents
Acids
Lyes
PVC self-extinguishing and flame retardant,
test method to UL VW-1/CSA FT1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

Please complete the above part number


for the colour required, using the following
table:
00 = green
01 = black
02 = blue
03 = brown
04 = red
05 = white
06 = grey
07 = violet
08 = yellow
09 = orange
10 = transparent
11 = pink
12 = beige
13 = green-yellow
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Due to design the constructional
alternations may the possible.

Application
For the internal wiring of switchbords, electrical equipment, e. g. households, radio or televisions and control desks.
Connecting wires in machines laid in protective tubes and flexible pipes and also for motors and transformators.
AWM = Appliance Wiring Material
For internal wirings for electrical equipment and control apparatus e.g. electronic assembly components.
UL = Underwriters Laboratories Inc. (USA)
CSA = Canadian Standards Association (Canada)
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
635xx
620xx
621xx
622xx
623xx

No.cores x
cross-sec.
mm
1x0,13
1x0,21
1x0,33
1x0,52
1x0,82

AWG-No. Outer
approx.
mm
26
1,4
24
1,5
22
1,6
20
1,8
18
2,1

Cop.
weight
kg/km
1,6
2,3
3,4
5,3
8,2

Weight
approx.
kg/km
3,2
4,3
6,0
8,5
12,5


Part no.
624xx
636xx
637xx
638xx

No.cores x
cross-sec.
mm
1x1,32
1x2,08
1x3,31
1x5,26

AWG-No. Outer
approx.
mm
16
2,4
14
3,0
12
3,9
10
4,1

Cop.
weight
kg/km
13,0
20,0
33,0
51,6

Weight
approx.
kg/km
18,5
29,0
40,0
61,0

Dimensions and specifications may be changed without prior notice. (RN06)

N 108
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

UL-Style 1569, CSA TR 64 PVC single cores, 105C, 300V




Technical data

Cable structure

PVC-single core to UL-Style and CSA-AWM


UL-Style 1569
CSA-AWM I A/B or TR 64
Temperature range
flexible -5 C bis +105 C
fixed installation -30 C bis +105 C
CSA-AWM I A/B or TR 64 +90 C
Nominal voltage 300 V
Test voltage 2000 V
Test voltage (Spark test)
AWG 26-20 = 4 kV
AWG 10-18 = 5 kV
Bending radius
once approx. 5x core
multiple approx. 10x core

Stranded copper conductor, tinned to


UL-Std.785
PVC-core insulation according to
UL-Std.1581 class43 Tab.50.182, heat and
damp resistant

Properties

Conditionally resistant to
Oils
Solvents
Acids
Lyes
PVC self-extinguishing and flame retardant,
test method to UL VW-1/CSA FT1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

Please complete the above part number


for the colour required, using the following
table:
00 = green
01 = black
02 = blue
03 = brown
04 = red
05 = white
06 = grey
07 = violet
08 = yellow
09 = orange
10 = transparent
11 = pink
12 = beige
13 = green-yellow
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Due to design the constructional
alternations may the possible.

Application
For the internal wiring of switchbords, electrical equipment, e. g. households, radio or televisions and control desks.
Connecting wires in machines laid in protective tubes and flexible pipes and also for motors and transformators.
AWM = Appliance Wiring Material
For internal wirings for electrical equipment and control apparatus e.g. electronic assembly components.
UL = Underwriters Laboratories Inc. (USA)
CSA = Canadian Standards Association (Canada)
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
660xx
661xx
662xx
663xx
664xx

No.cores x
cross-sec.
mm
1x0,13
1x0,21
1x0,33
1x0,52
1x0,82

AWG-No. Outer
approx.
mm
26
1,4
24
1,5
22
1,6
20
1,8
18
2,1

Cop.
weight
kg/km
1,6
2,3
3,4
5,3
8,2

Weight
approx.
kg/km
3,2
4,3
6,0
8,5
12,5


Part no.
665xx
666xx
667xx
668xx

No.cores x
cross-sec.
mm
1x1,32
1x2,08
1x3,31
1x5,26

AWG-No. Outer
approx.
mm
16
2,4
14
2,9
12
3,6
10
4,3

Cop.
weight
kg/km
13,0
20,0
33,0
51,6

Weight
approx.
kg/km
18,5
29,0
40,0
61,0

Dimensions and specifications may be changed without prior notice. (RN06)

N 109
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

UL-Style 1015 PVC single core, 600V




Technical data

Cable structure

PVC-single core as per ULAWM


Style1015/MTW and CSA-AWM/TEW as per
UL-Style1015 and CSA-TEW
Temperature range
flexible -5 C to +105 C
fixed installation -30 C to +105 C
Temperature at conductor
max. UL and CSA: +105 C
Nominal voltage 600 V
Test voltage (Spark test)
AWG 24: 4 kV
AWG 22 and 20: 5 kV
AWG 18 to 10: 6 kV
AWG 8: 7,5 kV
UL-type AWM + MTW 105 C 600 V
CSA-type AWM + TEW 105 C 600 V
Bending radius
once approx. 5x core
multiple approx. 10x core

Stranded copper conductor,tinned or plain


AWG-sizes as per table below
PVC-core insulation according to
UL-Standard 1581, class 43 and CSA-C22.2
No. 210 UL VW-1 and CSA FT1, heat and
damp resistant
For structural reasons, constructive
changes are possible

Properties

Conditionally resistant to
Oils
Solvents
Acids
Lyes
PVC self-extinguishing and flame
retardant, test method to UL VW-1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

Please complete the above part number


for the colour required, using the following
table:
00 = green / 01 = black /
02 = blue / 03 = brown /
04 = red / 05 = white /
06 = grey / 07 = violet /
08 = yellow / 09 = orange /
10 = transparent / 11 = pink /
12 = beige / 13 = green-yellow /
14 = blue/white / 15 = dark blue/white
27 = white/blue
(supply up to AWG 8)

Application
For the internal wiring of switchbords, electrical equipment, e. g. households, radio or televisions and control desks. Connecting wires in
machines laid in predective tubes and flexible pipes and also for motors and transformators.
UL bzw. CSA:
AWM = Appliance Wiring Material
For internal wirings for electrical equipment and control apparatus e. g. electronic assembly components. UL-MTW: Machine Tool-Wires
CSA-TEW: Equipment/Lead Wires
MTW = Machine Tool Wire
For the electronical installation of machine tools and the relative control
UL = Underwriters Laboratories Inc. (USA)
CSA = Canadian Standards Association (Kanada)
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
601xx
602xx
603xx
604xx
605xx
606xx
607xx
608xx
609xx
610xx
611xx
612xx

No.cores x
cross-sec.
mm
1x0,21
1x0,33
1x0,52
1x0,81
1x1,31
1x2,08
1x3,32
1x5,26
1x8,35
1x13,29
1x21,14
1x26,65

AWG-No. Outer
approx.
mm
24
2,2
22
2,4
20
2,5
18
2,8
16
3,1
14
3,5
12
4,0
10
4,6
8
6,5
6
8,0
4
9,5
3
10,4

Cop.
weight
kg/km
2,3
3,2
5,0
7,9
12,6
20,7
33,0
51,6
80,6
125,0
201,0
253,0

Weight
approx.
kg/km
8,0
10,0
12,0
16,0
22,0
31,0
45,0
65,0
110,0
175,0
260,0
340,0


Part no.
613xx
614xx
615xx
616xx
617xx
618xx
62501
62601
62701
62801
62901

No.cores x
cross-sec.
mm
1x33,61
1x42,38
1x53,47
1x67,4
1x84,97
1x107,17
1x127
1x152
1x178
1x203
1x254

AWG-No. Outer
approx.
mm
2
11,3
1
13,3
1/0
13,6
2/0
15,5
3/0
17,5
4/0
19,0
250 kcmil
21,2
300 kcmil
22,4
350 kcmil
25,3
400 kcmil
26,0
500 kcmil
28,0

Cop.
weight
kg/km
317,0
399,0
500,0
631,0
792,0
996,0
1178,0
1410,0
1645,0
1902,0
2345,0

Weight
approx.
kg/km
380,0
500,0
615,0
750,0
900,0
1070,0
1280,0
1518,0
1756,0
2002,0
2475,0

Dimensions and specifications may be changed without prior notice. (RN06)

N 110
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

THREENORM PVC single core, UL-Style 1013 and CSA 600V




Technical data

Cable structure

Properties

PVC-single cores according to DINVDE0281


part3 and HD21.3S3 UL-Style1013 and
CSA,CSA-AWMI/A/B
Temperature range
H05 V-K/H07 V-K
flexing +5 C to +70 C
fixed installation -10 C to +70 C
UL/CSA +90 C
Nominal voltage
H05 V-K U0/U 300/500 V (1 mm)
H07 V-K U0/U 450/750 V (1,5 mm)
UL/CSA 600 V AC
Test voltage
H05 V-K/H07 V-K 2000 V
Spark Test
AWG 20: 5 kV
>AWG 20: 6 kV
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
for permanent bending
ca. 10-15 core

Bare copper fine wire stranded to


DINVDE0295 cl.5, BS6360 cl.5, HD383
and IEC60228 cl.5
UL-Subject758 SectionG resp.ASTMB174
PVC core insulation TI1 to DINVDE0281
part1 and UL-Std.1581, class43,
CSA-C22.2 No.210 Tab.12 classH
Core colours to DINVDE0293

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
UL-VW-1 CSA FT1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

Tinned conductor on request.


AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
The cross-sections 0,5mm, 0,75mm and
1,0mm are according to H05V-K,
the cross-sections 1,5up to 120mm
according to H07V-K.

Application
Three norms approved connecting jumper wire primarily designed for exportes, used in machine tools. This wire is used for internal wiring
of switchboards and electrical equipment. The approbation of HAR-UL-CSA AWM make possible an economical storekeeping and simplification
of parts list.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


H05 V-K/mm
Cross-sec.
mm
/ AWG-no.
approx. RAL
Part no.
0,5 / 20
Part no.
0,75 / 19
Part no.
1 / 18

Outer
approx.
mm
2,5
2,65
2,8

Cop.
black
weight
kg/km
9005
63815
4,8
63831
7,2
63847
9,6

blue

brown

red

white

grey

vio

pink

og

green

ye

gn-ye

2-col.

dk-bu

trans

o.col.

5015
63817

8003
63818

3000
63819

1013
63820

7000
63821

4005
63822

3015
63824

2003
63828

6018
63825

1021
63823

63816

63830

5010
63827

63826

63829

63833

63834

63835

63836

63837

63838

63840

63844

63841

63839

63832

63846

63843

63842

63845

63849

63850

63851

63852

63853

63854

63856

63860

63857

63855

63848

63862

63859

63858

63861

Continuation

N 111
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

THREENORM PVC single core, UL-Style 1013 and CSA 600V


H07 V-K/mm
Cross-sec.
mm
/ AWG-no.
approx. RAL
Part no.
1,5 / 16
Part no.
2,5 / 14
Part no.
4 / 12
Part no.
6 / 10
Part no.
10 / 8
Part no.
16 / 6
Part no.
25 / 4
Part no.
35 / 2
Part no.
50 / 1
Part no.
70 / 2/0
Part no.
95 / 3/0
Part no.
120 / 4/0
Part no.
150 / 300 kcmil

Outer
approx.
mm
3,05
3,6
4,1
4,8
6,4
8,1
9,6
10,8
13,6
15,2
16,8
19,5
22,2

Cop.
black
weight
kg/km
9005
63863
14,4
63879
24,0
63895
38,0
63911
58,0
63927
96,0
63943
154,0
63959
240,0
63975
336,0
63991
480,0
64007
672,0
64023
912,0
64039
1152,0
64055
1440,0

blue

brown

red

white

grey

vio

pink

og

green

ye

gn-ye

2-col.

dk-bu

trans

o.col.

5015
63865

8003
63866

3000
63867

1013
63868

7000
63869

4005
63870

3015
63872

2003
63876

6018
63873

1021
63871

63864

63878

5010
63875

63874

63877

63881

63882

63883

63884

63885

63886

63888

63892

63889

63887

63880

63894

63891

63890

63893

63897

63898

63899

63900

63901

63902

63904

63908

63905

63903

63896

63910

63907

63906

63909

63913

63914

63915

63916

63917

63918

63920

63924

63921

63919

63912

63926

63923

63922

63925

63929

63930

63931

63932

63933

63934

63936

63940

63937

63935

63928

63942

63939

63938

63941

63945

63946

63947

63948

63949

63950

63952

63956

63953

63951

63944

63958

63955

63954

63957

63961

63962

63963

63964

63965

63966

63968

63972

63969

63967

63960

63974

63971

63970

63973

63977

63978

63979

63980

63981

63982

63984

63988

63985

63983

63976

63990

63987

63986

63989

63993

63994

63995

63996

63997

63998

64000

64004

64001

63999

63992

64006

64003

64002

64005

64009

64010

64011

64012

64013

64014

64016

64020

64017

64015

64008

64022

64019

64018

64021

64025

64026

64027

64028

64029

64030

64032

64036

64033

64031

64024

64038

64035

64034

64037

64041

64042

64043

64044

64045

64046

64048

64052

64049

64047

64040

64054

64051

64050

64053

64057

64058

64059

64060

64061

64062

64064

64068

64065

64063

64056

64070

64067

64066

64069

Dimensions and specifications may be changed without prior notice. (RN06)

Photo: HOMAG Holzbearbeitungssysteme AG

N 112
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

FIVENORM HAR-UL-CSA-AWM-MTW, PVC single core, UL-Style


10269/UL-Standard 1063, 600V, 105C


Technical data

Cable structure

Properties

PVC-single cores according to DINVDE0281


part7 and HD21.7S2, UL-Std.1063,
UL-Style10269 and CSA-TEW and
CSA-AWMI/A/B
Temperature range
H05 V2-K/H07 V2-K
flexing +5 C to +90 C
fixed installation -40 C to +90 C
UL (AWM) -40 C to +105 C
UL (MTW) -40 C to +90 C
CSA (TEW) -40 C to +105 C
Nominal voltage
H05 V2-K: U0/U 300/500 V (up to 1mm)
H07 V2-K: U0/U 450/750 V (1,5 mm)
UL (AWM) U 1000 V
UL (MTW)U 600 V
CSA (TEW) U 600 V
Test voltage
H05 V2-K/H07 V2-K 2000 V
Spark Test
AWG 20: 5 kV
>AWG 20: 6 kV
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
for permanent bending
ca. 10-15 core

Bare copper fine wire stranded to


DINVDE0295 cl.5, BS6360 cl.5, HD383
and IEC60228 cl.5 and UL-Subject758
SectionG
PVC core insulation TI3 to DINVDE0281
part1 and UL-Std.1581, class43,
CSA-C22.2 No.210 Tab.12 classH
Core colours to DINVDE0293
2-colour combination - Part No. on request


PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB),UL
VW-1,CSA FT1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

Tinned conductor on request.


The cross-sections 0,5mm, 0,75mm and
1,0mm are according to H05V2-K, the
cross-sections 1,5up to 35mm according
to H07V2-K, the cross-sections >35mm
are identified as H07 V-K.
Cross-sections up to 35mm is according
to DINVDE0281 part7. Due to this
cross-section >35mm is the type but with
an increased heat-resistant
PVC-compound.
Type H05 V:
approved one-colour mark: black, blue,
brown, grey, orange, pink, red, turquoise,
violet, white, green and yellow.
Two-coloured mark in any combination of
the above individual colours.
Type H07 V:
approved mark: black, blue, brown, grey,
orange, pink, red, turquoise, violet, white
and green-yellow.
Other marks are available as (H).

Application
Five norms approved connecting jumper wire primarily designed for exportes, used in machine tools. The approbation of HAR, UL-AWM,
UL-MTW, CSA-AWM, CSA-Equipment-wire make possible an economical storekeeping and simplification of parts list.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


H05 V2-K/mm
Cross-sec.
mm
/ AWG-no.
approx. RAL
Part no.
0,5 / 20
Part no.
0,75 / 19
Part no.
1 / 18

Outer
approx.
mm
2,5
2,65
2,8

Cop.
black
weight
kg/km
9005
64075
5,2
64091
7,2
64107
9,6

blue

brown

red

white

grey

vio

pink

og

green

ye

gn-ye

2-col.

dk-bu

trans

o.col.

5015
64077

8003
64078

3000
64079

1013
64080

7000
64081

4005
64082

3015
64084

2003
64088

6018
64085

1021
64083

64076

64090

5010
64087

64086

64089

64093

64094

64095

64096

64097

64098

64100

64104

64101

64099

64092

64106

64103

64102

64105

64109

64110

64111

64112

64113

64114

64116

64120

64117

64115

64108

64122

64119

64118

64121

Continuation

N 113
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

FIVENORM HAR-UL-CSA-AWM-MTW, PVC single core, UL-Style


10269/UL-Standard 1063, 600V, 105C
H07 V2-K/mm
Cross-sec.
mm
/ AWG-no.
approx. RAL
Part no.
1,5 / 16
Part no.
2,5 / 14
Part no.
4 / 12
Part no.
6 / 10
Part no.
10 / 8
Part no.
16 / 6
Part no.
25 / 4
Part no.
35 / 2
Part no.
50 / 1
Part no.
70 / 2/0
Part no.
95 / 3/0
Part no.
120 / 4/0
Part no.
150 / 300 kcmil

Outer
approx.
mm
3,05
3,6
4,1
4,8
6,4
8,1
9,6
10,8
13,6
15,2
16,8
19,5
22,2

Cop.
black
weight
kg/km
9005
64123
14,4
64139
24,0
64155
38,0
64171
58,0
64187
96,0
64203
154,0
64219
240,0
64235
336,0
64251
480,0
64267
672,0
64283
912,0
64299
1152,0
64315
1440,0

blue

brown

red

white

grey

vio

pink

og

green

ye

gn-ye

2-col.

dk-bu

trans

o.col.

5015
64125

8003
64126

3000
64127

1013
64128

7000
64129

4005
64130

3015
64132

2003
64136

6018
64133

1021
64131

64124

64138

5010
64135

64134

64137

64141

64142

64143

64144

64145

64146

64148

64152

64149

64147

64140

64154

64151

64150

64153

64157

64158

64159

64160

64161

64162

64164

64168

64165

64163

64156

64170

64167

64166

64169

64173

64174

64175

64176

64177

64178

64180

64184

64181

64179

64172

64186

64183

64182

64185

64189

64190

64191

64192

64193

64194

64196

64200

64197

64195

64188

64202

64199

64198

64201

64205

64206

64207

64208

64209

64210

64212

64216

64213

64211

64204

64218

64215

64214

64217

64221

64222

64223

64224

64225

64226

64228

64232

64229

64227

64220

64234

64231

64230

64233

64237

64238

64239

64240

64241

64242

64244

64248

64245

64243

64236

64250

64247

64246

64249

64253

64254

64255

64256

64257

64258

64260

64264

64261

64259

64252

64266

64263

64262

64265

64269

64270

64271

64272

64273

64274

64276

64280

64277

64275

64268

64282

64279

64278

64281

64285

64286

64287

64288

64289

64290

64292

64296

64293

64291

64284

64298

64295

64294

64297

64301

64302

64303

64304

64305

64306

64308

64312

64309

64307

64300

64314

64311

64310

64313

64317

64318

64319

64320

64321

64322

64324

64328

64325

64323

64316

64330

64327

64326

64329

Dimensions and specifications may be changed without prior notice. (RN06)

N 114
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

THHN/THWN 90C, 600V, UL listed, PVC + nylon single core




Technical data

Cable structure

Properties

PVC + Nylon insulated single cores as per


UL-Styles und NEC standard
Temperature range as per Styles
THHN: 90 C dry - NEC standard
THWN: 75 C wet - NEC standard
AWM: UL-Styles 1316 to 1321
105 C dry
80 C in oil
AWM: UL-Styles 1452, 1453
90 C dry
80 C in oil 1000 V
MTW: UL-Styles 1408 to 1414
90 C dry
80 C in oil 600 V
Nominal voltage 600 V
Minimum bending radius
8x core
Test voltage (Spark test)
AWG 14 to AWG 10 = 7,5 kV
AWG 8 to AWG 2/0 = 10 kV
AWG 3/0 to AWG 4/0 = 12,5 kV
kcmil 250 to kcmil 500 = 15 kV
kcmil 600 to kcmil 1000 = 17,5 kV

Bare copper conductor, AWG-sizes as per


given table below and ASTM B-3 and ASTM
B-8
Core insulation of PVC+Nylon-outer-sheath
Cores colour coded, colour identification
see below
Surface of jacket printed with markings:
14 to 1000 MCM THHN (stranded) - (size)
AWG Type MTW OR THHN OR THWN 600 V
OR GASOLINE AND OIL RESTSTANT II (UL) OR
AWM W-51554
14 to 10 AWG THHN (solid) - (size)
AWG TYPE THHN OR THWN 600 V OR
GASOLINE AND OIL RESISTANT II (UL) OR AWM

Resistant against
Oils
Gasoline
Water
Acids
Ozone
Lyes
Sunlight
Abrasion


Note

1 kcmil = 1000 circ mils = 0,5067 mm.


Please complete the above part number
for the colour required, using the following
code:
0 = green
1 = black
2 = blue
3 = brown
4 = red
5 = white
6 = grey
7 = yellow
8 = orange
9 = pink

Application
As flexible connecting cable in machines, switch and distribution cabinets, cable assemblies and for fixed indoor installation, in tubes and in
cable conduits.
AWM = Appliance Wiring Material / For internal wrings for electrical equipment and control apparatus e.g. radio and televisions, electronic
assembly component.
MTW = Machine Tool Wire / For the electronical installation of machine tools and the relative control.
THW = Thermoplastic PVC-insulated building wire, Heat resistant 75 C, for Wet and dry locations, flame retardant.
THHN = Thermoplastic PVC-insulated building wire, Nylon jacketed, 90 C 600 V, for dry and damp locations.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
6320x
6321x
6322x
6323x
6324x
6325x
6326x
6327x
6328x
6329x
6330x
6331x
6332x

Cross-sec. mm AWG-No.
2,08
3,32
5,26
8,35
13,39
21,14
26,65
33,61
42,38
53,47
67,4
84,97
107,17

14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0

AWG
size

Cond. make-up
n x wire

Outer
approx. mm

0,0147
0,0185
0,0234
0,0295
0,0378
0,0469
0,053
0,0591
0,0664
0,0745
0,0837
0,094
0,1055

19 x 0,38
19 x 0,48
19 x 0,6
19 x 0,75
19 x 0,96
19 x 1,19
19 x 1,336
19 x 1,5
19 x 1,686
19 x 1,89
19 x 2,126
19 x 2,387
19 x 2,68

AWG
size

Cond. make-up
n x wire

Outer
approx. mm

0,0822
0,09
0,0973
0,104
0,1162
0,0992
0,1109
0,128

37 x 2,088
37 x 2,286
37 x 2,47
37 x 2,7
37 x 2,95
61 x 2,52
61 x 2,82
61 x 3,25

18,29
19,56
21,08
22,35
24,13
26,75
29,36
33,27

3,0
3,4
4,3
5,5
6,6
8,4
9,1
10,0
11,4
12,4
13,7
15,0
16,5

Cop.
weight
kg/km
20,7
33,0
51,6
80,6
125,0
201,0
253,0
317,0
399,0
500,0
631,0
792,0
996,0

Weight
approx. kg/km

Cop.
weight
kg/km
1178,0
1410,0
1645,0
1902,0
2345,0
2920,0
3658,0
4858,0

Weight
approx. kg/km

25,0
37,0
60,0
95,0
143,0
229,0
282,0
349,0
449,0
557,0
691,0
861,0
1069,0


Part no.
63331
63341
63351
63361
63371
63381
63391
63401

Cross-sec. mm AWG-No.
127
152
178
203
254
304
380
507

250 kcmil
300 kcmil
350 kcmil
400 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil

1277,0
1515,0
1753,0
1998,0
2466,0
3000,0
3713,0
4796,0

Dimensions and specifications may be changed without prior notice. (RN06)

N 115
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PVC single cores According to CEI-20-22 II




Technical data

Cable structure

Properties

PVC-Single Cores as per Italian standard


CEI20-22II
Temperature range
flexing -5 C to +80 C
fixed installation -30 C to +80 C
Nominal voltage
U0/U 450/750 V = 1 mm and above
U0/U 300/500 V = 0,5 and 0,75 mm
U0/U 300/300 V = 0,35 mm
Test voltage 2500 V
Minimum bending radius
4-6x core

Bare fine wire stranded copper conductor


to CEI20-29 cl.5
PVC-core insulation R2 up to CEI20II,
cap.VI cl.3

Low smoke
Resistant to
Oil
Solvents
Acids
Lyes
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.


Application
As hook up wire, control cabinet building, in cable assembly manufacturing as well as in electronic applications.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Cross-sec.
mm
approx. RAL
Part no.
0,35
Part no.
0,5
Part no.
0,75
Part no.
1
Part no.
1,5
Part no.
2,5
Part no.
4
Part no.
6
Part no.
10
Part no.
16
Part no.
25
Part no.
35
Part no.
50
Part no.
70
Part no.
95
Part no.
120
Part no.
150

Outer
approx. mm

1,5

Cop.
weight
kg/km
2,5

Weight
black
approx. kg/km

3,6

2,6

4,8

6,0

2,8

7,2

10,0

3,2

9,6

16,0

3,5

14,4

21,0

4,2

24,0

32,0

4,6

38,0

48,0

6,3

58,0

69,0

7,6

96,0

117,0

8,8

154,0

180,0

11,0

240,0

266,0

12,5

336,0

366,0

14,5

480,0

515,0

16,5

672,0

741,0

18,5

912,0

950,0

21,0

1152,0

1230,0

23,0

1440,0

1500,0

9005
29600
29608
20
29616
18
29624
17
29632
16
29640
14
29648
12
29656
10
29664
8
29672
6
29680
4
29688
2
29696
1
29704
2/0
29712
3/0
29720
4/0
29728
300 kcmil

gn-ye

blue

brown

red

white

dk-bu

o.col.

29601
29609
20
29617
18
29625
17
29633
16
29641
14
29649
12
29657
10
29665
8
29673
6
29681
4
29689
2
29697
1
29705
2/0
29713
3/0
29721
4/0
29729
300 kcmil

5015
29602
29610
20
29618
18
29626
17
29634
16
29642
14
29650
12
29658
10
29666
8
29674
6
29682
4
29690
2
29698
1
29706
2/0
29714
3/0
29722
4/0
29730
300 kcmil

8003
29603
29611
20
29619
18
29627
17
29635
16
29643
14
29651
12
29659
10
29667
8
29675
6
29683
4
29691
2
29699
1
29707
2/0
29715
3/0
29723
4/0
29731
300 kcmil

3000
29604
29612
20
29620
18
29628
17
29636
16
29644
14
29652
12
29660
10
29668
8
29676
6
29684
4
29692
2
29700
1
29708
2/0
29716
3/0
29724
4/0
29732
300 kcmil

1013
29605
29613
20
29621
18
29629
17
29637
16
29645
14
29653
12
29661
10
29669
8
29677
6
29685
4
29693
2
29701
1
29709
2/0
29717
3/0
29725
4/0
29733
300 kcmil

5010
29606
29614
20
29622
18
29630
17
29638
16
29646
14
29654
12
29662
10
29670
8
29678
6
29686
4
29694
2
29702
1
29710
2/0
29718
3/0
29726
4/0
29734
300 kcmil

29607
29615
20
29623
18
29631
17
29639
16
29647
14
29655
12
29663
10
29671
8
29679
6
29687
4
29695
2
29703
1
29711
2/0
29719
3/0
29727
4/0
29735
300 kcmil

Dimensions and specifications may be changed without prior notice. (RN06)

N 116
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTHERM 145 300V, flexible single core, cross-linked, halogen-free




Technical data

Cable structure

Properties

Halogen-free single cores with increased


heat resistance according to
UL Style 3266
CSA CL 1252
Temperature range fixed
flexing -35 C to +120 C
fixed installation -55 C to +125 C
in short circuit +280 C
Nominal voltage U0/U 300/300 V
Test voltage 2000 V
Minimum bending radius
flexing approx. 12,5x core
fixed installation approx. 4x core
Caloric load values
see Technical Informations
Power ratings table
see Technical Informations

Tinned Cu wires, according to AWG-sizes


Conductor make-up:
AWG 24 to AWG 14 = 19-wires
AWG 12 = 65-wires
AWG 10 = 105-wires
Core insulation of polyolefin-copolymer,
cross-linked, flame retardant, halogen-free
Core colours see table below
Tests
Flame test to VDE0482-332-3, BS4066
part3/ DINEN60332-3/ IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Halogen-free accordingto VDE0482
part267/ DINEN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density to VDE 0482 part
1034-1+2/ IEC 61034-1+2 / DIN EN
61034-1+2 / BS 7622part 1+2 (equivalent
DIN VDE 0472 part 816)

Halogen-free
Lower propagation of fire
Low development of smoke and fumes
Good abrasion and notch resistance
Good resistance to oils and weathering
Resistant to UV radiation and ozone
Resistant to soldering temperatures
Thermal class B
These single-core cables are resistant to
melting, even when in contact with a
soldering iron at temperatures of between
300 C and 380 C, because of the
electron-beam cross-linking for the
insulation material
Due to the high temperature profile the
cross-section of conductor can under
certain circumstances be reduced, hereby
enabling a saving in space requirement and
weight
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.


Application
These temperature resistant single-core cables are used for the internal wiring of lighting fixtures, heaters, electrical machinery, switching
systems and distributors in equipment and plant and machinery, suitable for installation on, in and beneath plaster, in closed installation
ducts, as well as for traffic systems and outdoor applications. These cables are not approved for direct routing on racks, gutters or tanks.
For a protected installation, these cables may be used at a nominal voltage of up to 1000V alternating current or a direct current up to
750V when earthed. The maximum operating d.c. voltage used in rail vehicles shall not exceed 900V when earthed. These halogen-free
single core cables are characterised by their amazingly hight long-time resistance to temperature and feature among the leading halogen-free.
Flame resistant products in the world.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



AWG-No.

Outer Cop.
Weight black
approx. weight approx.
mm
kg/km kg/km
approx. RAL
9005
Part no.
61817
24
1,5
2,3
4,0
Part no.
61831
22
1,6
3,2
6,0
Part no.
61845
20
1,9
5,0
9,0
Part no.
61859
18
2,1
7,9
12,0
Part no.
61873
16
2,4
12,6
16,0
Part no.
61887
14
2,9
20,7
27,0
Part no.
61901
12
3,3
33,0
36,0
Part no.
61915
10
4,1
51,6
58,0

brown

red

white

grey

vio

green

Beige

pink

lt-bu

og

ye

gn-ye

2-col.

8003
61819

3000
61820

1013
61821

7000
61822

4005
61823

6018
61826

1001
61828

3015
61827

5015
61818

2003
61825

1021
61824

6018
61816

61829

61833

61834

61835

61836

61837

61840

61842

61841

61832

61839

61838

61830

61843

61847

61848

61849

61850

61851

61854

61856

61855

61846

61853

61852

61844

61857

61861

61862

61863

61864

61865

61868

61870

61869

61860

61867

61866

61858

61871

61875

61876

61877

61878

61879

61882

61884

61883

61874

61881

61880

61872

61885

61889

61890

61891

61892

61893

61896

61898

61897

61888

61895

61894

61886

61899

61903

61904

61905

61906

61907

61910

61912

61911

61902

61909

61908

61900

61913

61917

61918

61919

61920

61921

61924

61926

61925

61916

61923

61922

61914

61927

Dimensions and specifications may be changed without prior notice. (RN06)

N 117
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTHERM 145 600V, flexible single core, cross-linked, halogen-free




Technical data

Cable structure

Properties

Halogen-free single cores with increased


heat resistance according to
UL Style 3271
CSA CL 1251
Temperature range
flexing -35 C to +120 C
fixed installation -55 C to +125 C
in short circuit +280 C
Nominal voltage U 600 V
Test voltage 3500 V
Minimum bending radius
flexing approx. 12,5x core
fixed installation approx. 4x core
Caloric load values
see Technical Informations
Power ratings table
see Technical Informations

Tinned Cu wires, according to DINVDE0295


cl.5, BS6360 cl.5 and IEC60228 cl.5
Core insulation of polyolefin-copolymer,
cross-linked, flame retardant, halogen-free
Core colours see table below
Tests
Flame test to VDE0482 Teil266-2,
BS4066 part3/ DINEN50266-2/
IEC60332-3 (equivalent DINVDE0472
part804 test methodC)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Halogen-free accordingto VDE0482
part267/ DINEN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density to VDE 0482 part
1034-1+2/ IEC 61034-1+2 / DIN EN
61034-1+2 / BS 7622 part 1+2 (equivalent
DIN VDE 0472 part 816)

Halogen-free
Lower propagation of fire
Low development of smoke and fumes
Good abrasion and notch resistance
Good resistance to oils and weathering
Resistant to UV radiation and ozone
Resistant to soldering temperatures
Resistant to melting, even when in contact
with a soldering iron at temperatures of
between 300 C and 380 C, because of the
cross-linking for the insulation material
Due to the high temperature profile the
cross-section of conductor can under
certain circumstances be reduced, hereby
enabling a saving in space requirement and
weight
The materials in manufacture are
cadmium-free +contain no silicone +free
from substances harmful to the wetting
properties of lacquers

Application
These temperature resistant single-core cables are used for the internal wiring of lighting fixtures, heaters, electrical machinery, switching
systems and distributors in equipment and plant and machinery, suitable for installation on, in and beneath plaster, in closed installation
ducts, as well as for traffic systems and outdoor applications. These cables are not approved for direct routing on racks, gutters or tanks.
For a protected installation, these cables may be used at a nominal voltage of up to 1000V alternating current or a direct current up to
750V when earthed. The maximum operating d.c. voltage used in rail vehicles shall not exceed 900V when earthed.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



CrossOuter Cop.
Weight black
section
approx. weight approx.
mm
mm
kg/km kg/km
approx. RAL
9005
Part no.
59473
0,25
2,3
2,4
7,0
Part no.
59487
0,5
2,6
4,8
11,0
Part no.
59501
0,75
2,8
7,2
14,0
Part no.
59515
1
2,9
9,6
17,0
Part no.
59529
1,5
3,2
14,4
22,0
Part no.
59543
2,5
3,7
24,0
33,0
Part no.
59557
4
4,2
38,4
53,0
Part no.
59571
6
4,8
57,6
78,0
Part no.
59585
10
6,7
96,0
136,0
Part no.
59599
16
8,5
154,0
203,0
Part no.
59613
25
10,4
240,0
300,0
Part no.
59627
35
11,5
336,0
405,0
Part no.
59641
50
14,4
480,0
580,0

brown

red

white

grey

vio

green

Beige

pink

lt-bu

og

ye

gn-ye

2-col.

8003
59475

3000
59476

1013
59477

7000
59478

4005
59479

6018
59482

1001
59484

3015
59483

5015
59474

2003
59481

1021
59480

6018
59472

59485

59489

59490

59491

59492

59493

59496

59498

59497

59488

59495

59494

59486

59499

59503

59504

59505

59506

59507

59510

59512

59511

59502

59509

59508

59500

59513

59517

59518

59519

59520

59521

59524

59526

59525

59516

59523

59522

59514

59527

59531

59532

59533

59534

59535

59538

59540

59539

59530

59537

59536

59528

59541

59545

59546

59547

59548

59549

59552

59554

59553

59544

59551

59550

59542

59555

59559

59560

59561

59562

59563

59566

59568

59567

59558

59565

59564

59556

59569

59573

59574

59575

59576

59577

59580

59582

59581

59572

59579

59578

59570

59583

59587

59588

59589

59590

59591

59594

59596

59595

59586

59593

59592

59584

59597

59601

59602

59603

59604

59605

59608

59610

59609

59600

59607

59606

59598

59611

59615

59616

59617

59618

59619

59622

59624

59623

59614

59621

59620

59612

59625

59629

59630

59631

59632

59633

59636

59638

59637

59628

59635

59634

59626

59639

59643

59644

59645

59646

59647

59650

59652

59651

59642

59649

59648

59640

59653

Dimensions and specifications may be changed without prior notice. (RN06)

N 118
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

UL-Style 3135 silicone single cores cable, 600V / 200C, halogen-free




Technical data

Cable structure

Silicon single cores according UL subj.758


style3135
Temperature range
-60 C to +200 C
Nominal voltage 600 V
Test voltage 2000 V
Breakdown voltage min. 5000 V
Minimum bending radius
15x cable

Properties

Halogen-free
according to VDE0482 part267/
DINEN50267-2-1/ IEC60754-1 (equivalent
DINVDE0472 part815)
Resistant to
High molecular oils, fats from vegetables
and animals, alcohols, plasticizers and
clophenes, diluted acids, lyes and salt
dissolution, oxidation substances, tropical
influences and weather, lake water, oxygen


Tinned copper conductors


Stranded see table below
Silicon core insulation
Core colours see below

Note

Additional sizes on request.




Application
UL-approved single cores for use in high, temperature areas. They are used mainly in the steel producing industries, in aviation industries
as well as in ship building, cement, glas and ceramic factories.
AWM = Appliance Wiring Material
For internal wirings for electrical equipment and control apparatus e.g. electronic assembly components
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



AWG-No.
Part no.
24
Part no.
22
Part no.
20
Part no.
18
Part no.
16
Part no.
14
Part no.
12

Conductor
Core
construction approx. mm

Cop.
weight
kg/km

Weight
approx.
kg/km

1 x 0,5

2,1

1,9

6,3

3 x 0,4

2,4

3,6

9,2

5 x 0,4

2,6

6,0

12,3

7 x 0,4

2,8

8,6

15,5

11 x 0,4

3,0

13,3

21,0

17 x 0,4

3,4

20,5

29,7

27 x 0,4

3,8

32,6

43,2

black

blue

brown

red

white

grey

vio

green

47021
o. r.
47028
o. r.
47035
o. r.
47042
o. r.
47049
o. r.
47056
o. r.
47063
o. r.

47022
o. r.
47029
o. r.
47036
o. r.
47043
o. r.
47050
o. r.
47057
o. r.
47064
o. r.

47023
o. r.
47030
o. r.
47037
o. r.
47044
o. r.
47051
o. r.
47058
o. r.
47065
o. r.

47024
o. r.
47031
o. r.
47038
o. r.
47045
o. r.
47052
o. r.
47059
o. r.
47066
o. r.

47025
o. r.
47032
o. r.
47039
o. r.
47046
o. r.
47053
o. r.
47060
o. r.
47067
o. r.

47026
o. r.
47033
o. r.
47040
o. r.
47047
o. r.
47054
o. r.
47061
o. r.
47068
o. r.

47027
o. r.
47034
o. r.
47041
o. r.
47048
o. r.
47055
o. r.
47062
o. r.
47069
o. r.

47076
o. r.
47071
o. r.
47072
o. r.
47073
o. r.
47074
o. r.
47075
o. r.
47070
o. r.

Dimensions and specifications may be changed without prior notice. (RN06)

N 119
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Single 600-J/-O special single core cable, 0,6/1kV, meter marking




Technical data

Cable structure

Properties

Special PVC control cable according to


UL-Style10107 and CSAAWMI/IIA/B,
adapted to DINVDE0281 part3,
DINVDE0281 part13, to UL-Std.758
Temperature
range flexing -5 C bis +90 C
fixed installation -40 C bis +90 C
Permissible operating temperature
max. 90 C at conductor
Nominal voltage U0/U 06/1 kV
nach UL+CSA 600V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
1. Core insulation of special PVC, TI2 to
DINVDE0281 part1 and UL-Std.1581
class43, colour black or green-yellow
2. Core insulation (jacket) of special PVC,
TM2 to DINVDE0821 part1 and
ULStd.1581 class43, colour black
(RAL9005)
with meter marking, change-over in 2011


Chemical Resistance - see table Technical


informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB), UL
VW-1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Resistant to ultra violet rays


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
Single 600-CY -J/-O, see page N 121
alsoas 1000 V Style 10678 deliverable

Application
PVC Single cores suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced
movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burrial- or as underwater
cable.
These two norms approved single cores designed for exportorientated machinery manufacturer for machine tools, conveyor belts and
production lines.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
10881
1G6
10882
1x6
10883
1G10
10884
1x10
10885
1G16
10886
1x16
10887
1G25
10888
1x25
10889
1G35
10890
1x35
10891
1G50
10892
1x50

AWG-No. Core
colour
10
10
8
8
6
6
4
4
2
2
1
1

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
green-yellow
7,8
58,0
118,0
black
7,8
58,0
118,0
green-yellow
9,0
96,0
180,0
black
9,0
96,0
180,0
green-yellow 10,0
154,0
250,0
black
10,0
154,0
250,0
green-yellow 11,5
240,0
370,0
black
11,5
240,0
370,0
green-yellow 13,0
336,0
490,0
black
13,0
336,0
490,0
green-yellow 15,6
480,0
665,0
black
15,6
480,0
665,0


Part no. No.cores x
cross-sec.
mm
10893
1G70
10894
1x70
10895
1G95
10896
1x95
10897
1G120
10898
1x120
10899
1G150
10900
1x150
10901
1G185
10902
1x185
10903
1G240
10904
1x240

AWG-No. Core
colour
2/0
2/0
3/0
3/0
4/0
4/0
300 kcmil
300 kcmil
350 kcmil
350 kcmil
500 kcmil
500 kcmil

Outer
approx.
mm
green-yellow 17,9
black
17,9
green-yellow 19,5
black
19,5
green-yellow 22,3
black
22,3
green-yellow 25,0
black
25,0
green-yellow 28,6
black
28,6
green-yellow 31,4
black
31,4

Cop.
weight
kg/km
672,0
672,0
912,0
912,0
1152,0
1152,0
1440,0
1440,0
1776,0
1776,0
2304,0
2304,0

Weight
approx.
kg/km
910,0
910,0
1195,0
1195,0
1545,0
1545,0
1750,0
1750,0
2320,0
2320,0
2960,0
2960,0

Dimensions and specifications may be changed without prior notice. (RN06)

N 120
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Single 600-CY -J/-O special single core cable, Cu-screened,


EMC-preferred type, meter marking


Technical data

Cable structure

Properties

Special PVC control cable according to


UL-Style10107 and CSA AWMI/IIA/B,
adapted to DIN0281 part3, DINVDE0281
part13, to UL-Std.758
Temperature range
flexing -5 C bis +90 C
fixed installation -40 C bis +90 C
Permissible operating temperature
max. 90 C at conductor
Nominal voltage U0/U 06/1 kV
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
1. Core isulation of special PVC, TI2 to
DINVDE0281 part 1 and UL-Std.1581
class43, colour black or green-yellow
Tinned copper braided screening, coverage
approx. 85%
2. Core insulation of spezial PVC, TM2 to
DINVDE0281 part1 and UL Std.1581
class43, colour black (RAL9005)
with meter marking, change-over in 2011

Chemical Resistance - see table Technical


Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB) UL
VW-1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Resistant to ultra violet rays


Note

G = with green-yellow earth core;


x = without green-yellow earth core.
unscreened analogue type:
Single 600-J/-O, siehe Seite N 120
also as 1000 V Style 10678 deliverable

Application
PVC Single cores suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced
movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burrial-or as underwater
cable.
These two norms approved single cores designed for exportorientated machinery manufacturer for machine tools, conveyor belts and
production lines. These screened cables are particulary suitable for the interference-free transmission in instrumentation and control
engineering applications (electromagnetic compatibility).
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.cores x


cross-sec.
mm
10910
1G6
10911
1x6
10912
1G10
10913
1x10
10914
1G16
10915
1x16
10916
1G25
10917
1x25
10918
1G35
10919
1x35
10920
1G50
10921
1x50

AWG-No. Core
colour
10
10
8
8
6
6
4
4
2
2
1
1

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
green-yellow
7,6
72,0
140,0
black
7,6
72,0
140,0
green-yellow
9,4
130,0
230,0
black
9,4
130,0
230,0
green-yellow 10,4
190,0
300,0
black
10,4
190,0
300,0
green-yellow 12,0
260,0
420,0
black
12,0
260,0
420,0
green-yellow 14,4
405,0
615,0
black
14,4
405,0
615,0
green-yellow 16,4
560,0
825,0
black
16,4
560,0
825,0


Part no. No.cores x
cross-sec.
mm
10922
1G70
10923
1x70
10924
1G95
10925
1x95
10926
1G120
10927
1x120
10928
1G150
10929
1x150
10930
1G185
10931
1x185
10932
1G240
10933
1x240

AWG-No. Core
colour
2/0
2/0
3/0
3/0
4/0
4/0
300 kcmil
300 kcmil
350 kcmil
350 kcmil
500 kcmil
500 kcmil

Outer
approx.
mm
green-yellow 17,4
black
17,4
green-yellow 20,1
black
20,1
green-yellow 23,0
black
23,0
green-yellow 26,1
black
26,1
green-yellow 29,3
black
29,3
green-yellow 32,2
black
32,2

Cop.
weight
kg/km
780,0
780,0
1030,0
1030,0
1285,0
1285,0
1570,0
1570,0
1940,0
1940,0
2530,0
2530,0

Weight
approx.
kg/km
1090,0
1090,0
1395,0
1395,0
1770,0
1770,0
1930,0
1930,0
2635,0
2635,0
3380,0
3380,0

Dimensions and specifications may be changed without prior notice. (RN06)

N 121
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Single 602-RC* -J/O special single core cable for drag


chains, 90C, 600V, meter marking


Technical data

Cable structure

Properties

Special PVC control cable according to


UL-Style10107 and CSA AWM I/II AB, core
according to DINVDE0281 part3 (except
300mm)
Temperature range
flexing -5 C to +90 C
fixed installation -40 C to +90 C
Permissible operating temperature
max. +90 C at conductor
Nominal voltage
according to UL+CSA 600 V
U0/U 600/1000 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 3x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, extra fine wire conductors,


to DINVDE0295 cl.6, col.4, BS6360 cl.6
and IEC60228 cl.6, however by 185mm
up to 300mm with reduced single wire-,
max. 0,30mm
1. Core insulation of special PVC, TI3 to
DINVDE0281 part1 and UL-Std.1581
class43 90 C, wall-thickness to
UL-Style10107 and DINVDE0281 part3,
colour black or green-yellow
2. Core insulation (jacket) of special PVC,
YM5 to DINVDE0207 part5 and
UL-Std.1581 class43 90 C, wall-thickness
to UL-Style10107,
colour black (RAL 9005)
with meter marking, change-over in 2011

Chemical Resistance - see table Technical


Informations
Resistant to mineral oils, synthetic oils and
lubricating coolants.
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB) UL
VW-1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Tests
According to UL-Style10107/ UL-Std.1581,
CSAC22.2 No210
Core according to DINVDE0281 part3 and
part1 (HD21.3)


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
300 mm in adaption to DINVDE0281
screened analogue type:
Single 602-RC*-CY -J/O, see page N 123

Application
High flexible special single core cables for drag chains are used for flexible use for medium mechanical stresses with free movement without
tensile stress or forced movements in dry, moist and wet rooms. These two-norm cables primarily designed for exportorientated machinery
manufacturer for flexible applications in machineries, machine tools, robot technics, for movable automated machinery parts.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
RC = Robotics Cable
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
69601
1G10
69602
1x10
69603
1G16
69604
1x16
69605
1G25
69606
1x25
69607
1G35
69608
1x35
69609
1G50
69610
1x50
69611
1G70
69612
1x70

AWG-No. Core
colour
8
8
6
6
4
4
2
2
1
1
2/0
2/0

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
green-yellow
9,4
96,0
180,0
black
9,4
96,0
180,0
green-yellow 10,5
154,0
250,0
black
10,5
154,0
250,0
green-yellow 11,6
240,0
370,0
black
11,6
240,0
370,0
green-yellow 14,5
336,0
490,0
black
14,5
336,0
490,0
green-yellow 16,6
480,0
665,0
black
16,6
480,0
665,0
green-yellow 18,4
672,0
910,0
black
18,4
672,0
910,0


Part no. No.cores x
cross-sec.
mm
69613
1G95
69614
1x95
69615
1G120
69616
1x120
69617
1G150
69618
1x150
69619
1G185
69620
1x185
69621
1G240
69622
1x240
69623
1G300
69624
1x300

AWG-No. Core
colour
3/0
3/0
4/0
4/0
300 kcmil
300 kcmil
350 kcmil
350 kcmil
500 kcmil
500 kcmil
600 kcmil
600 kcmil

Outer
approx.
mm
green-yellow 20,5
black
20,5
green-yellow 23,0
black
23,0
green-yellow 25,2
black
25,2
green-yellow 29,0
black
29,0
green-yellow 32,5
black
32,5
green-yellow 35,4
black
35,4

Cop.
weight
kg/km
912,0
912,0
1152,0
1152,0
1440,0
1440,0
1776,0
1776,0
2304,0
2304,0
2880,0
2880,0

Weight
approx.
kg/km
1195,0
1195,0
1545,0
1545,0
1750,0
1750,0
2320,0
2320,0
2960,0
2960,0
3550,0
3550,0

Dimensions and specifications may be changed without prior notice. (RN06)

N 122
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Single 602-RC* -CY -J/O special single core


cable for drag chains, 90C, 600V, EMC-preferred type, meter marking


Technical data

Cable structure

Properties

Special PVC control cable according to


UL-Style10107 and CSA AWM I/II A/B, core
according to DINVDE0281 part3 (except
300mm)
Temperature range
flexing -5 C to +90 C
fixed installation -40 C to +90 C
Permissible operating temperature
max. +90 C at conductor
Nominal voltage
according to UL+CSA 600 V
U0/U 600/1000 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 3x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, extra fine wire conductors,


to DINVDE0295 cl.6, col.4, BS6360 cl.6
and IEC60228 cl.6, however by 185mm
up to 300mm with reduced single wire-,
max. 0,30 mm
1. Core insulation of special PVC, TI3 to
DINVDE0281 part1 and UL Std.1581
class43 90 C, wall-thickness to
UL-Style10107 and DINVDE0281 part3,
colour black or green-yellow
Tinned copper braided screening, coverage
approx. 80%
2. Core insulation (jacket) of special PVC,
YM5 to DINVDE0207 part5 and
UL-Std.1581 class43 90 C, wall-thickness
to UL-Style10107,
colour orange (RAL 2003)
with meter marking, change-over in 2011

Chemical Resistance - see table Technical


Informations
Resistant to mineral oils, synthetic oils and
lubricating coolants.
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB), UL
VW-1
The materials used are cadmium-free and
contain no silicone and free from
substances harmful to the wetting
properties of lacquers
Tests
According to UL-Style10107/ UL Std1581,
CSAC22.2 No210
Core according to DINVDE0281 part3 and
part1 (HD21.3)


Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
300 mm in adaption to DINVDE0281.
non screened analogue type:
Single 602-RC* -J/O, see page N 122

Application
High flexible special single core screened cables for drag chains are used for flexible use for medium mechanical stresses with free movement
without tensile stress or forced movements in dry, moist and wet rooms. These two-norm cables primarily designed for exportorientated
machinery manufacturer for flexible applications in machineries, machine tools, robot technics, for movable automated machinery parts.
These screened cables are particulary suitable for the interference-free transmission in instrumentation and control engineering applications
(electromagnetic compatibility). For applications which go beyond standard solutions we recommend for our especially developed enquiry
sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection table
for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
RC = Robotics Cable


Part no.
69631
69632
69633
69634
69635
69636
69637
69638
69639
69640
69641
69642

No.cores x
cross-sec.
mm
1G10
1x10
1G16
1x16
1G25
1x25
1G35
1x35
1G50
1x50
1G70
1x70

AWG-No. Outer
approx.
mm
8
10,0
8
10,0
6
11,1
6
11,1
4
12,3
4
12,3
2
15,1
2
15,1
1
17,2
1
17,2
2/0
19,0
2/0
19,0

Cop.
weight
kg/km
130,0
130,0
190,0
190,0
260,0
260,0
405,0
405,0
560,0
560,0
780,0
780,0

Weight
approx.
kg/km
230,0
230,0
300,0
300,0
420,0
420,0
615,0
615,0
825,0
825,0
1090,0
1090,0


Part no.
69643
69644
69645
69646
69647
69648
69649
69650
69651
69652
69653
69654

No.cores x
cross-sec.
mm
1G95
1x95
1G120
1x120
1G150
1x150
1G185
1x185
1G240
1x240
1G300
1x300

AWG-No. Outer
approx.
mm
3/0
22,0
3/0
22,0
4/0
23,6
4/0
23,6
300 kcmil
25,8
300 kcmil
25,8
350 kcmil
29,8
350 kcmil
29,8
500 kcmil
33,5
500 kcmil
33,5
600 kcmil
36,2
600 kcmil
36,2

Cop.
weight
kg/km
1030,0
1030,0
1285,0
1285,0
1570,0
1570,0
1940,0
1940,0
2530,0
2530,0
3140,0
3140,0

Weight
approx.
kg/km
1395,0
1395,0
1770,0
1770,0
1930,0
1930,0
2635,0
2635,0
3380,0
3380,0
4120,0
4120,0

Dimensions and specifications may be changed without prior notice. (RN06)

N 123
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 600-PUR -J/-O special single cores for


drag chains, halogen-free, meter marking


Technical data

Cable structure

Properties

Special drag chain core line for extreme


mechanical stresses adapted to
DINVDE0281 Part3 and ULstyle10553
Temperature range
flexing -30 C to +80 C
fixed installation -40 C to +90 C
Nominal voltage U0/U 600/1000 V
Test voltage 3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing 5 x core
fixed installation 3 x core

Bare copper conductor, ultra-fine wire to


DINVDE0295 cl.6, column4, BS6360 cl.6
and/or IEC60228 cl.6
1st core insulation from thermoplastic
polymer in either black or green/yellow
2nd core insulation from special
polyurethane, TMPU adapted to
DINVDE0282, Part10, low-adhesion
Sheath colour:black (RAL 9005)
with meter marking, change-over in 2011

Flame retardant, FT1, VW-1


Halogen-free
Abrasion resistant
Very good oil resistance
Very good alternating bending strength
Very high resistance to mechanical stresses
Higher notch resistance
Ozone and UV-resistant
Coolant resistant
The materials used in manufacture are
silicon and cadmium-free and contain no
substances harmful to the wetting
properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
screened analogue type:
MULTISPEED 600-C-PUR -J/-O,
see page N 125

Application

These special drag chain core cables permit extended use with extreme requirements, with free movement, without tensile stresses or
forced movements.
Suitable for installation in long traverse paths and high speeds in dry, high temperature influence in dry, moist and wet environments and
in the open air. These cables can be used for all applications demanding the highest requirements in flexibility, abrasion resistance, ozone
and chemical resistance.
For applications extending beyond standard solutions (e.g. composting plants or high-lift conveyor systems working at extremely low
speeds), we recommend that you request our questionnaire, which has been especially designed for energy supply systems. Before installation
in cable trays please read the instructions.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
25888
25269
25889
25270
25890
25271
25891
25272
25892
25273
25893
25274
25894
25275

No.cores x
cross-sec.
mm
1G6
1x6
1G10
1x10
1G16
1x16
1G25
1x25
1G35
1x35
1G50
1x50
1G70
1x70

Outer
Cop.
approx. mm weight
kg/km
7,2
58,0
7,2
58,0
8,4
96,0
8,4
96,0
9,5
154,0
9,5
154,0
11,0
240,0
11,0
240,0
13,0
336,0
13,0
336,0
15,4
480,0
15,4
480,0
17,2
672,0
17,2
672,0

Weight
approx.
kg/km
80,0
80,0
130,0
130,0
181,0
181,0
274,0
274,0
398,0
398,0
529,0
529,0
717,0
717,0

AWG-No.
10
10
8
8
6
6
4
4
2
2
1
1
2/0
2/0


Part no.
25895
25276
25896
25277
25897
25278
25898
25279
25899
25280
25900
25281

No.cores x
cross-sec.
mm
1G95
1x95
1G120
1x120
1G150
1x150
1G185
1x185
1G240
1x240
1G300
1x300

Outer
Cop.
approx. mm weight
kg/km
20,0
912,0
20,0
912,0
21,0
1152,0
21,0
1152,0
23,8
1440,0
23,8
1440,0
26,2
1776,0
26,2
1776,0
29,8
2304,0
29,8
2304,0
33,1
2880,0
33,1
2880,0

Weight
approx.
kg/km
1050,0
1050,0
1240,0
1240,0
1524,0
1524,0
1932,0
1932,0
2467,0
2467,0
3140,0
3140,0

AWG-No.
3/0
3/0
4/0
4/0
300 kcmil
300 kcmil
350 kcmil
350 kcmil
500 kcmil
500 kcmil
600 kcmil
600 kcmil

Dimensions and specifications may be changed without prior notice. (RN06)

N 124
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

MULTISPEED 600-C-PUR -J/-O special cable for


drag chains, screened, halogen-free, EMC-preferred type, meter marking


Technical data

Cable structure

Properties

Special drag chain core cable for


mechanical stresses adapted to
DINVDE0281 Part3 and UL-Style10553
Temperature range
flexing -30 C to +80 C
fixed installation -40 C to +90 C
Nominal voltage U0/U 600/1000 V
Test voltage 3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing 5 x core
fixed installation 3 x core

Bare copper conductor, ultra-fine wire to


DINVDE0295 cl.6, column4, BS6360 cl.6
and/or IEC60228 cl.6
1st core insulation from thermoplastic
polymer in either black or green/yellow
Braided screen of tinned Cu wires,
coverage approx. 85%
Core wrapping with fleece
2nd insulation from special polyurethane,
TMPU adapted to DINVDE0282, Part10,
low-adhesion
Sheath colour black (RAL 9005)
with meter marking, change-over in 2011

Flame retardant, FT1, VW-1


Halogen-free
Abrasion resistant
Very good oil resistance
Very good alternating bending strength
Very high resistance to mechanical stresses
Improved notch resistance
Ozone and UV-resistant
Coolant-resistant
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
Please observe applicable installation
regulations for use in energy supply chains.
unscreened analogue type:
MULTISPEED 600-PUR -J/-O,
see page N 124

Application

These special drag chain core cables permit extended use with extreme requirements, with free movement, without tensile stresses or
forced movements. Suitable for installation in long traverse paths and high speeds in dry, high temperature influence in dry, moist and wet
environments and in the open air.
These cables can be used for all applications demanding the highest requirements in flexibility, abrasion resistance, ozone and chemical
resistance. The copper screening assures a disturbance-free data and signal transmission for measuring and control systems. For applications
extending beyond standard solutions (e.g. composting plants or high-lift conveyor systems working at extremely low speeds), we recommend
that you request our questionnaire, which has been especially designed for energy supply systems. Before installation in cable trays please
read the instructions.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
25901
25282
25902
25283
25903
25284
25904
25285
25905
25286
25906
25287
25907
25288

No.cores x
cross-sec.
mm
1G6
1x6
1G10
1x10
1G16
1x16
1G25
1x25
1G35
1x35
1G50
1x50
1G70
1x70

Outer
Cop.
approx. mm weight
kg/km
7,8
71,0
7,8
71,0
9,7
122,0
9,7
122,0
11,7
180,0
11,7
180,0
13,2
282,0
13,2
282,0
15,2
386,0
15,2
386,0
18,7
535,0
18,7
535,0
21,2
750,0
21,2
750,0

Weight
approx.
kg/km
101,0
101,0
168,0
168,0
217,0
217,0
342,0
342,0
468,0
468,0
584,0
584,0
822,0
822,0

AWG-No.
10
10
8
8
6
6
4
4
2
2
1
1
2/0
2/0


Part no.
25908
25289
25909
25290
25910
25291
25911
25292
25912
25293
25913
25294

No.cores x
cross-sec.
mm
1G95
1x95
1G120
1x120
1G150
1x150
1G185
1x185
1G240
1x240
1G300
1x300

Outer
Cop.
approx. mm weight
kg/km
23,4
1004,0
23,4
1004,0
24,5
1260,0
24,5
1260,0
27,8
1570,0
27,8
1570,0
29,4
1911,0
29,4
1911,0
34,2
2451,0
34,2
2451,0
37,4
2997,0
37,4
2997,0

Weight
approx.
kg/km
1190,0
1190,0
1400,0
1400,0
1710,0
1710,0
2021,0
2021,0
2601,0
2601,0
3257,0
3257,0

AWG-No.
3/0
3/0
4/0
4/0
300 kcmil
300 kcmil
350 kcmil
350 kcmil
500 kcmil
500 kcmil
600 kcmil
600 kcmil

Dimensions and specifications may be changed without prior notice. (RN06)

N 125
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

... for static installation


TOPSERV 108 PVC
TOPSERV 112 PVC
TOPSERV 119 PVC
TOPGEBER 511 PVC
... for dynamic installation
TOPSERV 109 PUR
TOPSERV 113 PUR
TOPSERV 121 PUR
TOPGEBER 512 PUR
TOPFLEX 600 VFD
TOPFLEX 650 VFD
TOPSERV 600 VFD
TOPSERV 650 VFD
TOPFLEX-EMV-UV-2YSLCYK-J
TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J
TOPFLEX EMV UV 2YSLC11Y-J
TOPFLEX MOTOR EMV 1/1
TOPFLEX MOTOR EMV 3/3
TOPFLEX MOTOR 103
VERTEILERFLEX Zwei-Norm
Photo: HELUKABEL

UL/CSA
Motor, Servo &
Feedback Cables

N 126
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPSERV 108 PVC Motor cable without pair according


to Siemens Standard 6FX5008 with PVC-outer sheath for fixed or not
constantly movements 0,6/1kV


Technical data

Cable structure

Properties

Special PVC Motorcable acc. to


ULAWMStyle2570 and CSAAWM
Temperature range
flexing -0 C to +60 C
fixed installation -20 C to +80 C
Nominal voltage
acc. to UL/CSA 1000 V
acc. to VDE U0/U = 600/1000 V
A.c.
test voltage, 50 Hz

power supply cores 4000 V
Minimum bending radius
flexing approx. 15x cable
fixed installation approx. 5x cable
max. 100.000 cycles

Bare copper, fine wire conductors acc. to


DINEN60228 cl.5
core insulation Polypropylenuntil 6mm;
PVC from 10mm
Black power supply cores with
whiteimprint
Green-yellow earth core
power supply cores laid up with optimal lay
length and stabilising filler
Overall screening from tinned copper braid,
optimal. coverage approx. 85%
PVC outer sheath
Sheath colour orange (RAL 2003) according
to DESINA
with meter marking, change-over in 2011


low capacitance until 6mm(included)


oilresistant PVC outer sheath
PVC sheath flame retardant according to
VDE0482-332-1-1 to -1-3
Optimum compliance with requirements
for electromagnetic compatibility (EMC) by
approx. 85% coverage from the braided
screen
These cables are produced to high quality
specifications and conform to the
DESINA-standard
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

the corresponding Encodercables mit PVCJacket can be found under heading TOPGEBER 511 PVC
the Motorcables for application in drag chain with PUR Jacket can be found under heading TOPSERV 109 PUR
Brackets ( ) indicate screen.
Desina: Explanation: see introduction.
SIEMENS product designations 6FX 5008- are registered trademarks of Siemens AG, and are to be used only for purposes of comparison.

Application
low cost alternativ to Motorcables with PUR Jacket for fix instalation.The cables have an overall screen to ensure EMC compatibility, i.e. for
protection against electromagnetic interference. Production is based on the specifications of established manufacturers of servo-drives
and controls, as well as on various VDE, UL and CSA standards. Applications include machine, plant and robot construction, automation,
drive, control and production engineering.
Attractive for export-oriented mechanical and system engineering.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part
no.
707250
707251
707252
707253
707254
707255
707256
707257
707258

No.cores x
cross-sec.
mm
( 4G1,5)
( 4G2,5)
( 4G4)
( 4G6)
( 4G10)
( 4G16)
( 4G25)
( 4G35)
( 4G50)

for
system

OEM
Part no.

Jacket
colour

Siemens
Siemens
Siemens
Siemens
Siemens
Siemens
Siemens
Siemens
Siemens

6FX5008-1BB11
6FX5008-1BB21
6FX5008-1BB31
6FX5008-1BB41
6FX5008-1BB51
6FX5008-1BB61
6FX5008-1BB25
6FX5008-1BB35
6FX5008-1BB50

Orange RAL 2003


Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003

Outer
approx.
mm
8,0
9,6
11,0
13,1
19,3
23,3
26,9
30,3
34,5

Cop.
weight
kg/km
78,0
130,0
198,0
288,0
463,0
701,0
1068,0
1449,0
2096,0

Weight
approx.
kg/km
118,0
179,0
260,0
638,0
705,0
1055,0
1509,0
1976,0
2781,0

AWG-No.
16
14
12
10
8
6
4
2
1

Dimensions and specifications may be changed without prior notice. (RN07)

N 127
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPSERV 112 PVC Servo cable with 1 signal pair according


to Siemens Standard 6FX5008 and Lenze Standard with PVC-sheath for fixed
or not constantly movements 0,6/1kV


Technical data

Cable structure

Properties

Special PVC Motorcable acc. to


ULAWMStyle2570 and 21179 CSAAWM
Temperature range
flexing -0 C to +60 C
fixed installation -20 C to +80 C
Nominal voltage
acc. to UL/CSA 1000 V
acc. to VDE
power supply cores U0/U 600/1000 V
control cores U0/U 300/500 V
A.c. test voltage, 50 Hz
power supply cores 4000 V
control cores 1000V
Minimum bending radius
flexing approx. 15x cable
fixed installation approx. 5x cable
max. 100.000 cycles

Bare copper, fine wire conductors acc. to


DINEN60228 cl.5
core insulation Polypropylen until 6mm;
PVC from 10mm
Black power supply cores with white
imprint
Green-yellow earth core
Black control cores with white imprint
Screening of the control cores in pairs
wrapped with plastic foil and tinned copper
braided screening, approx. coverage 85%
Control cores stranded in pairs and laid up
in layers together with the power supply
cores with optimal lay length and stabilising
filler
Overall screening from tinned copper braid,
optimal. coverage approx. 85%
PVC outer sheath
Sheath colour orange (RAL 2003) according
to DESINA
 marking
with meter


low capacitance until 6mm(included)


oilresistant PVC outer sheath
PVC sheath flame retardant according to
VDE0482-332-1-1 to -1-3
Optimum compliance with requirements
for electromagnetic compatibility (EMC) by
approx. 85% coverage from the braided
screen
These cables are produced to high quality
specifications and conform to the
DESINA-standard
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

the corresponding Encoder cables mit PVC Jacket can be foundunder heading TOPGEBER 511 PVC
the Motorcables for application in drag chain with PUR Jacket can be found under heading TOPSERV 113 PUR
Brackets ( ) indicate screen.
Desina: Explanation: see introduction.
SIEMENS product designations 6FX 5008- are registered trademarks of Siemens AG, and are to be used only for purposes of comparison.
LENZE product designations are registered trademarks of LENZE AG, and are to be used only for purposes of comparison.

Application
Low cost alternativ to supply cables with PUR Jacket for fix instalation or occasional moving applications. The combination of feeder cores
with the control cores for the braking function in these cables is ideal.
The cables have an overall screen to ensure EMC compatibility, i.e. for protection against electromagnetic interference. Production is based
on the specifications of established manufacturers of servo-drives and controls, as well as on various VDE, UL and CSA standards. Applications
include machine, plant and robot construction, automation, drive, control and production engineering.
Attractive for export-oriented mechanical and system engineering.
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part
no.
707221
707222
707223
707224
707225

No.cores x
cross-sec.
mm
( 4G1 + (2 x 0,5))
( 4G1,5 + (2 x 0,5))
( 4G2,5 + (2 x 0,5))
( 4G4 + (2 x 1,0))
( 4G6 + (2 x 1,0))

for
system

OEM
Part no.

Jacket
colour

Lenze
Lenze
Lenze
Lenze
Lenze

Orange RAL 2003


Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003

No.cores x
cross-sec.
mm
( 4G1,5 + (2 x 1,5))
( 4G2,5 + (2 x 1,5))
( 4G4 + (2 x 1,5))
( 4G6 + (2 x 1,5))
( 4G10 + (2 x 1,5))
( 4G16 + (2 x 1,5))
( 4G25 + (2 x 1,5))
( 4G35 + (2 x 1,5))
( 4G50 + (2 x 1,5))

for
system

OEM
Part no.

Jacket
colour

Siemens
Siemens
Siemens
Siemens
Siemens
Siemens
Siemens
Siemens
Siemens

6FX5008-1BA11
6FX5008-1BA21
6FX5008-1BA31
6FX5008-1BA41
6FX5008-1BA51
6FX5008-1BA61
6FX5008-1BA25
6FX5008-1BA35
6FX5008-1BA50

Orange RAL 2003


Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003

Outer
approx.
mm
9,5
11,0
12,3
14,6
16,7

Cop.
weight
kg/km
88,0
106,0
152,0
229,0
312,0

Weight
approx.
kg/km
136,0
178,0
274,0
365,0
515,0

AWG-No.

Outer
approx.
mm
10,4
12,0
13,6
15,6
21,0
24,1
28,3
31,4
34,5

Cop.
weight
kg/km
140,0
185,0
257,0
348,0
416,0
476,0
555,0
611,0
710,0

Weight
approx.
kg/km
190,0
256,0
341,0
454,0
794,0
1125,0
1576,0
2049,0
2818,0

AWG-No.

17
16
14
12
10


Part
no.
707280
707281
707282
707283
707284
707285
707286
707287
707288

16
14
12
10
8
6
4
2
1

Dimensions and specifications may be changed without prior notice. (RN07)

N 128
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPSERV 119 PVC Servo cable with 2 signal pairs analogue


Indramat Standard with PVC-sheath for fixed or not constantly movements 0,6/1kV


Technical data

Cable structure

Properties

Special PVC Motorcable acc. to


ULAWMStyle2570 CSAAWM
Temperature range
flexing -0 C to +60 C
fixed installation -20 C to +80 C
Nominal voltage
acc. to UL/CSA 1000 V
acc. to VDE
power supply cores U0/U 600/1000 V
control cores U0/U 300/500 V
A.c. test voltage, 50 Hz
power supply cores 4000 V
control cores 1000V
Minimum bending radius
flexing approx. 15x cable
fixed installation approx. 5x cable
max. 100.000 cycles

Bare copper, fine wire conductors acc. to


DINEN60228 cl.5
core insulation Polypropylen until 6mm;
PVC from 10mm
Black power supply cores with white
imprint
Green-yellow earth core
Black control cores with white imprint
Screening of the control cores in pairs
wrapped with plastic foil and tinned copper
braided screening, approx. coverage 85%
Control cores stranded in pairs and laid up
in layers together with the power supply
cores with optimal lay length and stabilising
filler
Overall screening from tinned copper braid,
optimal. coverage approx. 85%
PVC outer sheath
Sheath colour orange (RAL 2003) according
to DESINA
with meter marking


low capacitance until 6mm(included)


oilresistant PVC outer sheath
PVC sheath flame retardant according to
VDE0482-332-1-1 to -1-3
Optimum compliance with requirements
for electromagnetic compatibility (EMC) by
approx. 85% coverage from the braided
screen
These cables are produced to high quality
specifications and conform to the
DESINA-standard
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note
the corresponding Encoder cables mit PVC Jacket can be found underheading TOPGEBER 511 PVC
the Motorcables for application in drag chain with PUR Jacket can be found under heading TOPSERV 121 PUR
Brackets ( ) indicate screen.
Desina: Explanation: see introduction.
INDRAMAT product designations INK- are registered trademarks of Bosch Rexroth AG and are to be used only for purposes of comparison.


Application
The combination of supply cores with the control cores for the braking function and the thermal protection in these cables is ideal. Precision
servomotors, as used today in many areas of highly-automated manufacturing processes, call for high-quality, reliable and long-lasting
cables. These requirements are met to a high degree by these cables. The cables have an additional overall screen to ensure EMC compatibility,
i.e. for protection against electromagnetic interference. Production is based on the specifications of established manufacturers of servo-drives
and controls, as well as on various VDE, UL and CSA standards. Applications include machine, plant and robot construction, automation,
drive, control and production engineering.
Attractive for export-oriented mechanical and system engineering.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part
no.
707290
707291
707292
707293
707294
707295
707296

No.cores x
cross-sec.
mm
( 4G1 + 2 x (2 x 0,75))
( 4G1,5 + 2 x (2 x 0,75))
( 4G2,5 + 2 x (2 x 1,0))
( 4G4 + (2 x 1,0) + (2 x 1,5))
( 4G6 + (2 x 1,0) + (2 x 1,5))
( 4G10 + (2 x 1,0) + (2 x 1,5))
( 4G16 + 2 x (2 x 1,5))

for
system

OEM
Part no.

Jacket
colour

Indramat
Indramat
Indramat
Indramat
Indramat
Indramat
Indramat

INK-0653
INK-0650
INK-0602
INK-0603
INK-0604
INK-0605
INK-0606

Orange RAL 2003


Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003

Outer
approx.
mm
12,0
12,4
14,6
16,0
18,8
22,4
26,9

Cop.
weight
kg/km
130,0
155,0
216,0
297,0
374,0
545,0
804,0

Weight
approx.
kg/km
218,0
256,0
346,0
443,0
596,0
825,0
1217,0

AWG-No.
-

Dimensions and specifications may be changed without prior notice. (RN07)

N 129
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPGEBER 511 PVC Feedback cables according to Siemens-,


Lenze- or Indramat Standard with PVC-sheath for fixed or not constantly
movements


Technical data

Cable structure

Properties

Special PVC feedback cable acc. to ULAWM


style20233 and CSA
Temperature range
flexing -0 C to +60 C
fixed installation -20 C to +80 C
Nominal voltage
acc. to UL 300 V
0,14-0,34 mm: 350 V
0,5-1,0 mm: 500 V
A.c. test voltage, 50 Hz
core/core 2000 V
core/screen 1000 V
Minimum bending radius
flexing approx. 12x cable
fixed installation approx. 6x cable
max. 100.000 cycles

Bare copper, ultra-fine wire conductors


acc. to DINVDE0295 cl.6
Core insulation of special polypropylene
Core colours on request
Overall screening of tinned copper wire
braid with tinned drain wire, coverage
approx. 85%
Polyester foil
PVC outer sheath
Sheath colour green (RAL 6018) acc. to
DESINA or orange
with meter marking, change-over in 2009
Colour code:
Part No. 78081
0,5 mm whrd, whye, whbk, whbu
Part No. 79613
0,5 mm wh, bn


low capacitance
oilresistant PVC outer sheath
PVC sheath flame retardant according to
VDE0482-332-1-1 to -1-3
Optimum compliance with requirements
for electromagnetic compatibility (EMC) by
approx. 85% coverage from the braided
screen
These cables are produced to high quality
specifications and conform to the
DESINA-standard
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

the corresponding Motor- and Servocableswith PVC Jacket can be found under heading TOPSERV 112 PVC
the Encodercables for application in drag chain with PUR Jacket can be found under heading TOPGEBER 512 PUR
Brackets ( ) indicate screen.
SIEMENS product designations 6FX 5008-... are registered trademarks of Siemens AG, and are to be used only for purposes of comparison.
INDRAMAT product designations INK- are registered trademarks of Bosch-Rexroth AG, and are to be used only for purposes of comparison.
LENZE product designations are registered trademarks ofLENZE AG, and are to be used only for purposes of comparison.
Desina: Explanation: see introduction.

Application
Low cost alternativ to Motorcables with PUR Jacket for fix instalation or occasional moving applications.These low-capacitance incremental
encoder cables or position feedback cables transmit the control pulses for positioning and operating characteristics of servomotors. These
cables are used as connecting cables for tachos, brakes and pulse generators inindustrial equipment, machine tools, control and automation
equipment.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part
no.
707417
707389
707390
803672
802471
705461
707392
707394
707077
707397
707398

No.cores x
cross-sec.
mm
( 4 x 2x0,38 + 4 x 0,5)
( 3 x (2x0,14) + 4 x 0,14 + 2 x 0,5)
(3 x (2 x 0,14) + 4 x 0,14 + 4 x 0,25 + 2 x 0,5)
(2 x 2 x 0,22 + 1 x 2 x 0,34)
(2 x 2 x 0,22)
( 4 x 2x0,25 + 2 x 0,5)
( 4 x 2x0,25 + 2 x 1,0)
(4 x 2 x 0,14 + 4 x 1,0 + (4 x 0,14))
3 x (2 x 0,14) + (2 x 0,5)
4 x (2 x 0,14) + (2 x 1,0)
3 x (2 x 0,14) + (3 x 0,14)

for
system

OEM
Part no.

Jacket
colour

Siemens
Siemens
Siemens
Siemens
Siemens
Indramat
Indramat
Indramat
Lenze
Lenze
Lenze

6FX 5008-1BD21
6FX 5008-1BD41
6FX 5008-1BD51
6FX 8008-2DC00
6FX 8008-1DC00
INK-0448
INK-0209
INK-0532
-

Green
Green
Green
Green
Green
Orange
Orange
Orange
Green
Green
Green

Outer
approx.
mm
8,9
8,8
9,6
6,9
6,9
8,4
8,8
9,7
9,3
11,0
9,2

Cop.
weight
kg/km
70,3
58,0
70,7
38,0
35,0
50,0
64,0
86,0
46,0
70,0
41,0

Weight
approx.
kg/km
117,8
118,9
137,7
61,0
71,0
99,0
119,0
149,0
95,0
145,0
102,0

AWG-No.
-

Dimensions and specifications may be changed without prior notice. (RN07)

N 130
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPSERV 109 PUR PUR, high flexible motor cable


for drag chain without pairs according to Siemens Standard
6FX8008-plus 0,6/1kV


Technical data

Cable structure

Properties

Special PUR drag chain cable acc. to


ULAWM Style21223 CSAAWM
Temperature range
flexing -30 C to +80 C
fixed installation -40 C to +90 C
Nominal voltage
acc. to UL/CSA 1000 V
acc. to VDE U0/U 600/1000 V
A.c. test voltage, 50 Hz
4000 V
Insulation resistance
min. 20 MOhm x km
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
flexing approx. 7,5x cable
fixed installation approx. 4x cable

Bare copper, ultra-fine wire acc. to


DINVDE0295 cl.6 and/or IEC60228 cl.6
core insulation Polypropylen, halogen-free
Black cores with sequential numbering
imprinted in white
Green-yellow earth core
Cores stranded together with optimal
lay-length and stabilising filler
Fleece wrapping facilitates sliding
Tinned copper braided screening, coverage
approx. 85%
PUR outer sheath
Sheath colour orange (RAL 2003) according
to DESINA
with meter marking, change-over in 2011


Low adhesion, flame retardant, extremely


abrasion resistant, halogen-free, resistant
to UV, oil, hydrolysis and microbial attack
PUR sheath
PUR sheath self-extinguishing and flame
retardant according to VDE0482-332-1-2,
DIN EN60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Optimized insulation materials ensure
resistance to oils (including mineral oils),
greases, coolants, hydraulic fluids as well
as many alkalis and solvents.
Optimum compliance with requirements
for electromagnetic compatibility (EMC) by
approx. 85% coverage from the braided
screen
These cables are produced to high quality
specifications and conform to the DESINA
standard.
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note
the corresponding Encoder cables can be found under TOPGEBER 512PUR
the Motorcables forstatic application or application with occasional movementwith PVC Jacket can be found under TOPSERV 109 PVC
SIEMENS product designations 6FX 8008-plus... are registered trademarks of Siemens AG, and are to be used only for purposes of comparison.
For extreme applications extending beyond standard solutions we recommend that you request our questionnaire, which has been
especially designed for energy supply systems.
Please observe applicable installation regulations for use in energy supply chains.
Desina: Explanation: see introduction.

Application
Supply cable optimised especially for the supply of DNC motors. These cables are specially designed for use in power drag chains, handling
equipment, robotics, tooling machinery, processing and manufacturing machinery.
The optimised outside diameter, reduced weight and excellent torsion characteristics facilitate use in multi-shift operation with extreme
alternating bending stress cycles.
Particularly recommended as a supply cable between frequency converters and servomotors.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part
no.
75943
75944
75945
75946
75947
75948
75949
75950
75951
700437
700897

No.cores x
cross-sec.
mm
( 4G1,5)
( 4G2,5)
( 4G4)
( 4G6)
( 4G10)
( 4G16)
( 4G25)
( 4G35)
( 4G50)
( 4G70)
( 4G95)

for
system

OEM
Part no.

Jacket
colour

Siemens
Siemens
Siemens
Siemens
Siemens
Siemens
Siemens
Siemens
Siemens
Siemens
Siemens

6FX8008-1BB11
6FX8008-1BB21
6FX8008-1BB31
6FX8008-1BB41
6FX8008-1BB51
6FX8008-1BB61
6FX8008-1BB25
6FX8008-1BB35
6FX8008-1BB50
6FX8008-1BB70
-

Orange RAL 2003


Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003

Outer
approx.
mm
9,1
10,6
11,9
14,5
17,5
21,6
25,4
28,6
33,4
42,5
49,5

Cop.
weight
kg/km
90,0
132,0
204,0
315,0
488,0
769,0
1100,0
1510,0
2133,0
3029,0
4606,0

Weight
approx.
kg/km
159,0
235,0
323,0
464,0
672,0
1089,0
1523,0
2080,0
2710,0
4123,0
0,0

AWG-No.
16
14
12
10
8
6
4
2
1
2/0
3/0

Dimensions and specifications may be changed without prior notice. (RN07)

N 131
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPSERV 113 PUR PUR, high flexible servo cable


for drag chain with 1 signal pair according to Siemens Standard
6FX8008-plus and Lenze 0,6/1kV


Technical data

Cable structure

Properties

Special PUR drag chain cable acc. to


ULAWMStyle21223, 20234 and CSAAWM
VDE-registered
Temperature range
flexing -30 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage
acc. to UL/CSA 1000 V
acc. to VDE
power supply cores U0/U 600/1000 V
control cores U0/U 300/500 V
A.c. test voltage, 50 Hz
power supply cores 4000 V
control cores 1000 V
Insulation resistance
min. 20 Ohm x km
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
flexing approx. 7,5x cable
fixed installation approx. 4x cable

Bare copper, ultra-fine wire conductors


acc. to DINVDE0295 cl.6 and/or IEC60228
cl.6
Polypropylenecore insulation, halogen-free
Black power supply cores with white
imprint
Green-yellow earth core
Black control cores with white imprint
Screening of the control cores in pairs
wrapped with plastic aluminium foil, copper
drain-wire tinned and tinned copper
braided screening, approx. coverage 85%
Control cores stranded in pairs and laid up
in layers together with the power supply
cores with optimal lay length and stabilising
filler
Fleece wrapping facilitates sliding
Overall screening from tinned copper braid,
optimal. coverage approx. 85%
PUR outer sheath
Sheath colour orange (RAL 2003) according
to DESINA
with meter marking, change-over in 2011

low capacitance
PUR outer sheath: low adhesion, extremely
abrasion resistant, halogen-free, resistant
to UV-, oil-, hydrolysis and microbial attack
PUR sheath: self-extinguishing and flame
retardant according to VDE0482-332-1-2,
DIN EN60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Optimized insulation materials ensure
resistance to oils (including mineral oils),
greases, coolants, hydraulic fluids as well
as many alkalis and solvents.
Optimum compliance with requirements
for electromagnetic compatibility (EMC) by
approx. 85% coverage from the braided
screen
These cables are produced to high quality
specifications and conform to the
DESINA-standard
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

the corresponding encoder cables with PUR jacket can be found under TOPGEBER 512 PUR
the Servocables for stativ application oder occasional movements can be found under TOPSERV 112 PVC
Brackets ( ) indicate screen.
Desina: Explanation: see introduction.
SIEMENS product designations 6FX 8008-are registered trademarks of Siemens AG, and are to be used only for purposes of comparison.
LENZE product designationsare registered trademarks of LENZE AG, and are to be used only for purposes of comparison.

Application
The combination of supply cores with the control cores for the braking function in these cables is ideal. Precision servomotors, as used
today in many areas of highly-automated manufacturing processes, call for high-quality, reliable and long-lasting cables. These requirements
are met to a high degree by these cables. The cables have an additional overall screen to ensure EMC compatibility, i.e. for protection against
electromagnetic interference. Production is based on the specifications of established manufacturers of servo-drives and controls, as well
as on various VDE, UL and CSA standards. Applications include machine, plant and robot construction, automation, drive, control and
production engineering.
Attractive for export-oriented mechanical and system engineering.
Please observe applicable installation regulations for use in energy supply chains.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Continuation

N 132
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPSERV 113 PUR PUR, high flexible servo cable


for drag chain with 1 signal pair according to Siemens Standard
6FX8008-plus and Lenze 0,6/1kV

Part
no.
707228
707229
707230
707231
707232
707746
707747

No.cores x
cross-sec.
mm
( 4G1 + (2 x 0,5))
( 4G1,5 + (2 x 0,5))
( 4G2,5 + (2 x 0,5))
( 4G4 + (2 x 1,0))
( 4G6 + (2 x 1,0))
( 4G10 + (2 x 1,0))
( 4G16 + (2 x 1,0))

for
system

OEM
Part no.

Jacket
colour

Lenze
Lenze
Lenze
Lenze
Lenze
Lenze
Lenze

Orange RAL 2003


Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003

No.cores x
cross-sec.
mm
( 4G1,5 + (2 x 1,5))
( 4G2,5 + (2 x 1,5))
( 4G4 + (2 x 1,5))
( 4G6 + (2 x 1,5))
( 4G10 + (2 x 1,5))
( 4G16 + (2 x 1,5))
( 4G25 + (2 x 1,5))
( 4G35 + (2 x 1,5))
( 4G50 + (2 x 1,5))

for
system

OEM
Part no.

Jacket
colour

Siemens
Siemens
Siemens
Siemens
Siemens
Siemens
Siemens
Siemens
Siemens

6FX8008-1BA11
6FX8008-1BA21
6FX8008-1BA31
6FX8008-1BA41
6FX8008-1BA51
6FX8008-1BA61
6FX8008-1BA25
6FX8008-1BA35
6FX8008-1BA50

Orange RAL 2003


Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003

No.cores x
cross-sec.
mm
( 4G1 + (2 x 0,75))
( 4G1,5 + (2 x 0,5))
( 4G1,5 + (2 x 1,0))
( 4G2,5 + (2 x 1,0))
( 4G4 + (2 x 1,0))
( 4G6 + (2 x 1,0))
( 4G10 + (2 x 1,0))
( 4G16 + (2 x 1,0))
( 4G25 + (2 x 1,0))
( 4G35 + (2 x 1,0))
( 4G50 + (2 x 1,0))

for
system

OEM
Part no.

Jacket
colour

Orange RAL 2003


Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003

Outer
approx.
mm
10,5
11,5
13,2
14,6
16,8
20,1
23,8

Cop.
weight
kg/km
88,0
106,0
152,0
229,0
312,0
508,0
751,0

Weight
approx.
kg/km
161,0
186,0
263,0
337,0
488,0
688,0
1046,0

AWG-No.

Outer
approx.
mm
11,6
13,4
14,8
16,8
19,4
23,1
26,6
30,9
34,0

Cop.
weight
kg/km
148,0
187,0
268,0
358,0
584,0
825,0
1283,0
1850,0
2540,0

Weight
approx.
kg/km
228,0
346,0
393,0
519,0
849,0
1260,0
1620,0
2166,0
3039,0

AWG-No.

Outer
approx.
mm
11,5
11,5
11,5
13,6
15,0
16,1
20,2
23,8
27,0
31,9
36,7

Cop.
weight
kg/km
134,0
127,0
138,0
177,0
258,0
348,0
574,0
815,0
1273,0
1840,0
2530,0

Weight
approx.
kg/km
250,0
240,0
254,0
328,0
462,0
596,0
912,0
1194,0
1499,0
1992,0
2880,0

AWG-No.

16
16
14
12
10
8
6


Part
no.
78948
78949
78950
78951
78952
75956
75957
75958
75959

16
14
12
10
8
6
4
2
1


Part
no.
77376
700199
74506
74507
74508
74514
74509
74510
74511
74512
74513

17
16
16
14
12
10
8
6
4
2
1

Dimensions and specifications may be changed without prior notice.

N 133
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPSERV 121 PUR PUR, high flexible servo cable


for drag chain with 2 Signal pairs according to Indramat-Standard INK


Technical data

Cable structure

Properties

Special PUR drag chain cable acc. to


ULAWMStyle20234 and CSAAWM
Temperature range
flexing -30 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage
acc. to UL/CSA 1000 V
acc. to VDE
power supply cores U0/U 600/1000 V
control cores U0/U 300/500 V
A.c. test voltage, 50 Hz
power supply cores 4000 V
control cores 1000 V
Insulation resistance
min. 20 Ohm x km
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
flexing approx. 7,5x cable
fixed installation approx. 4x cable

Bare copper, ultrafine wire conductors acc.


to DINVDE0295 Kl.6 bzw. IEC60228 cl.6
core insulation Polypropylen until 6mm
Black power supply cores with white
imprint
Green-yellow earth core
Black control cores with white imprint
Screening of the control cores in pairs
wrapped with plastic aluminium foil, copper
drain-wire tinned and tinned copper
braided screening, approx. coverage 85%
Control cores stranded in pairs and laid up
in layers together with the power supply
cores with optimal lay length and stabilising
filler
Overall screening from tinned copper braid,
optimal. coverage approx. 85%
PUR outer sheath
Sheath colour orange (RAL 2003) according
to DESINA
with meter marking, change-over in 2011


low capacitance
PUR outer sheath: low adhesion, extremely
abrasion resistant, halogen-free, resistant
to UV-, oil-, hydrolysis and microbial attack
PUR sheath: self-extinguishing and flame
retardant, test method B acc. to
DINVDE0472 part804 and IEC60332-1
Optimum compliance with requirements
for electromagnetic compatibility (EMC) by
approx. 85% coverage from the braided
screen
These cables are produced to high quality
specifications and conform to the
DESINA-standard
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note
the corresponding Encoder cablescan be found under TOPGEBER 512 PUR
the Servocables for stativ application oder occasional movements can be found under TOPSERV 119 PVC
Indramat Artikelbezeichnungen INK sind eingetragene Warenzeichen der Bosch Rexroth AG und dienen nur zu Vergleichszwecken


Application
The combination of supply cores with the control cores for the braking function and the thermal protection in these cables is ideal. Precision
servomotors, as used today in many areas of highly-automated manufacturing processes, call for high-quality, reliable and long-lasting
cables. These requirements are met to a high degree by these cables. The cables have an additional overall screen to ensure EMC compatibility,
i.e. for protection against electromagnetic interference. Production is based on the specifications of established manufacturers of servo-drives
and controls, as well as on various VDE, UL and CSA standards. Applications include machine, plant and robot construction, automation,
drive, control and production engineering.
Attractive for export-oriented mechanical and system engineering.
Please observe applicable installation regulations for use in energy supply chains.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part
no.
706003
73774
76103
73579
700561
73580
78955
74094
700562
78956
74095
700563
78957
74096
700564
78958
75978
75979
75980
700565

No.cores x
cross-sec.
mm
( 4G0,75 + (2 x 0,5))
( 4G1 + 2 x (2 x 0,75))
( 4G1,5 + 2 x (2 x 0,5))
( 4G1,5 + 2 x (2 x 1,0))
( 4G1,5 + 2 x (2 x 0,75))
( 4G2,5 + 2 x (2 x 1,0))
( 4G2,5 + 2 x (2 x 1,5))
( 4G4 + 2 x (2 x 1,0))
( 4G4 + (2 x 1,0) + (2 x 1,5))
( 4G4 + 2 x (2 x 1,5))
( 4G6 + 2 x (2 x 1,0))
( 4G6 + (2 x 1,0) + (2 x 1,5))
( 4G6 + 2 x (2 x 1,5))
( 4G10 + 2 x (2 x 1,0))
( 4G10 + (2 x 1,0) + (2 x 1,5))
( 4G10 + 2 x (2 x 1,5))
( 4G16 + 2 x (2 x 1,5))
( 4G25 + 2 x (2 x 1,5))
( 4G35 + 2 x (2 x 1,5))
( 4G50 + 2 x (2 x 2,5))

for
system

OEM
Part no.

Jacket
colour

Indramat
Indramat
Indramat
Indramat
Indramat
Indramat
Indramat
Indramat
Indramat
Indramat
Indramat

INK-0670
INK-0653
INK-0650
INK-0602
INK-0603
INK-0604
INK-0605
INK-0606
INK-0607
INK-0667
INK-0668

Orange RAL 2003


Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003
Orange RAL 2003

Outer
approx.
mm
10,0
11,5
12,4
12,6
12,2
14,6
15,6
16,2
16,0
16,7
18,2
18,8
19,0
21,5
22,4
22,4
26,9
28,0
32,5
37,0

Cop.
weight
kg/km
77,0
148,0
145,0
182,0
170,0
229,0
241,0
312,0
318,0
324,0
437,0
445,0
450,0
609,0
610,0
625,0
904,0
1323,0
1621,0
2600,0

Weight
approx.
kg/km
166,0
254,0
250,0
262,0
290,0
336,0
350,0
475,0
485,0
490,0
606,0
615,0
621,0
905,0
915,0
925,0
1226,0
1595,0
2196,0
3000,0

AWG-No.
17
17
17
16
16
14
14
12
12
12
10
10
10
8
8
8
6
4
2
1

Dimensions and specifications may be changed without prior notice. (RN07)

N 134
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPGEBER 512 PUR PUR, high flexible Feedback


cable for drag chain according to Siemens, Indramat, Lenze and other
Standards


Technical data

Cable structure

Properties

Special PUR drag chain feedback cable acc.


to ULAWM style20233 and 20236and CSA
Temperature range
flexing -30 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage
acc. to UL 300 V
0,14-0,34 mm: 350 V
0,5-1,0 mm: 500 V
A.c. test voltage, 50 Hz
core/core 2000 V
core/screen 1000 V
Mutual capacitance at 800 Hz
core/core approx. 70 nF/km
core/screen approx. 110 nF/km
Insulation resistance
min. 20 MOhm x km
Coupling resistance
max. 250 Ohm
Minimum bending radius
flexing approx. 10x cable
fixed installation approx. 6x cable

tinned copper, ultra-fine wire conductors


acc. to DINVDE0295 cl.6
Core insulation of special polypropylene
Core colours on demand
Fleece wrapping facilitates sliding
Overall screening of tinned copper wire
braid with tinned drain wire, coverage
approx. 85%
Polyester foil
PUR outer sheath
Sheath colour green (RAL 6018) acc. to
DESINA or orange
with meter marking, change-over in 2011


PUR outer sheath: low adhesion, extremely


abrasion resistant, halogen-free, resistant
to UV-, oil-, hydrolysis and microbial attack
Special feature: These cables are produced
to high quality specifications and conform
to the DESINA-standard
Due to the high grade special core
insulation, the PUR sheath and the highly
flexible conductor, these cables are ideally
suitable for use in drag chains and provide
high functional reliability
Optimum compliance with requirements
for electromagnetic compatibility (EMC) by
approx. 85% coverage from the braided
screen
Particularly attractive for export-oriented
markets due to UL/CSA approval
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

the corresponding Motor- and Servocables can be found under TOPSERV 109 respectively 113 PUR
Encoder cablesfor static application with PVC Jacket can be found under TOPGEBER 511 PVC
Brackets ( ) indicate screen.
SIEMENS product designations 6FX 8008-... are registered trademarks of Siemens AG, and are to be used only for purposes of comparison.
INDRAMAT product designations INK- are registered trademarks of Bosch-Rexroth AG, and are to be used only for purposes of comparison.
Desina: Explanation: see introduction.

Application
These low-capacitance incremental encoder cables or position feedback cables transmit the control pulses for positioning and operating
characteristics of servomotors. These cables are used as connecting cables for tachos, brakes and pulse generators in applications subjected
to heavy mechanical stresses in industrial equipment, machine tools, control and automation equipment.
Please observe applicable installation regulations for use in energy supply chains.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Continuation

N 135
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPGEBER 512 PUR PUR, high flexible Feedback


cable for drag chain according to Siemens, Indramat, Lenze and other
Standards


Part
no.
700655
78081
707400
700657
700540
700654
700653
78079
802473
706333
705413
707403
707404
707405
707406
707407
702050
78080
77741
707738
707739
707740
707408
707418
707409
77743
79513
707410
700560
77753
78963
78828
79613
77744
78372
77750
705221

No.cores x
cross-sec.
mm
( 8 x 2x0,18)
( 4 x 2x0,38 + 4 x 0,5)
( 3 x (2x0,14) + 2 x 0,5)
( 3 x (2x0,14) + 4 x 0,14 + 2 x 0,5)
( 3 x (2x0,14) + 4 x 0,14 + 4 x 0,25 + 2 x 0,5)
( 4 x 2x0,18)
( 2 x 2x0,18)
( 12x0,25)
( 2 x 2x0,15 + 2 x 0,38)
( 5 x 2x0,25 + 2 x 0,5)
( 3 x 2x0,25 + 2 x 0,5)
( 3 x 2x0,25)
( 5 x 2x0,14 + 2 x 0,5)
3 x (2 x 0,14) + (2 x 0,5)
4 x (2 x 0,14) + (2 x 1,0)
3 x (2 x 0,14) + (3 x 0,14)
(4 x 2 x 0,25 + 2 x 1,0)
( 4 x 2x0,25 + 2 x 0,5)
( 9x0,5)
( 4 x 2x0,25 + 2 x 1,0)
( 4 x 2x0,25 + 2 x 0,5)
( 9x0,5)
(4 x 2 x 0,14 + 4 x 1,0 + (4 x 0,14))
(3 x (2 x 0,25) + 3 x 0,25 + 2 x 1,0)
(2 x 2 x 0,25 + 2 x 0,5)
( 3 x (2x0,14) + 2 x (1 x 0,5))
( 4 x 2x0,14 + 4 x 0,5)
( 3 x 2x0,14 + 2 x 1,0)
(4 x 2 x 0,14 + (4 x 0,14) + 4 x 0,5)
( 10x0,14 + 2 x 0,5)
( 5 x 2x0,14 + 2 x 0,5)
( 3 x 2x0,25)
( 5 x 2x0,38 + 2 x 0,5)
( 3 x (2x0,14) + 2 x 1,0)
( 3 x 2x0,14 + 2 x 0,5)
( 4 x (2x0,25) + 2 x 1,0)
( 4 x 2x0,25)

for
system

OEM
Part no.

Jacket
colour

Siemens
Siemens
Siemens
Siemens
Siemens
Siemens
Siemens
Siemens
Siemens
Berger Lahr
Elau
B+R
B+R
Lenze
Lenze
Lenze
Indramat
Indramat
Indramat
Indramat
Indramat
Indramat
Indramat
Indramat
Indramat
Heidenhain
Heidenhain
Heidenhain
Heidenhain
Heidenhain
Baumller
-

6FX 8008-1BD11
6FX 8008-1BD21
6FX 8008-1BD31
6FX 8008-1BD41
6FX 8008-1BD51
6FX 8008-1BD61
6FX 8008-1BD71
6FX 8008-1BD81
6FX 8008-2DC00
INK-0209 grn
INK-0448 grn
INK-0208 grn
INK-0209
INK-0448
INK-0208
INK-0532
INK-0280
INK-0750
-

Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Orange
Orange
Orange
Orange
Orange
Orange
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green

Outer
approx.
mm
7,8
9,8
9,0
8,9
9,6
6,4
5,0
7,5
7,0
8,8
7,4
6,5
8,7
9,8
11,3
10,3
8,8
8,5
8,8
8,8
8,5
8,8
9,7
9,0
7,2
8,4
8,5
9,1
8,3
7,2
9,0
7,2
8,6
8,2
7,2
10,5
7,5

Cop.
weight
kg/km
54,0
83,0
74,0
66,0
75,0
35,0
24,0
65,0
41,0
69,0
43,0
31,0
48,0
42,0
66,0
41,0
64,0
51,0
69,0
64,0
51,0
69,0
81,0
84,0
38,0
54,0
52,0
72,0
81,0
43,0
72,0
55,0
69,0
71,0
35,0
93,0
39,0

Weight
approx.
kg/km
79,0
135,0
119,0
120,0
138,0
57,0
42,0
74,0
72,0
127,0
82,0
60,0
98,0
98,0
144,0
127,0
99,0
106,0
124,0
99,0
106,0
124,0
142,0
134,7
79,0
109,0
100,0
132,0
104,0
83,0
98,0
83,0
130,0
107,0
67,0
175,0
88,0

AWG-No.
24
21
21
26
24
24
24
24
24
24
24
24
24
24
20
20
20
20
20
20
20
26
26
26
26
24
21
26
26
24
24

Dimensions and specifications may be changed without prior notice. (RN07)

N 136
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX 600 VFD EMC-preferred type, flexible motor power supply


cable, oil-resistant, NFPA 79 Edition 2007


Technical data

Cable structure

Properties

PVC motor supply cable according to


UL1277
Temperature range
-25C to +90C
Nominal voltage
TC 600 V
WTTC 1000 V
Test voltage 4000 V
Minimum bending radius
Flexing 6x cable
Coupling resistance
Max. 250 Ohm/km

Tinned copper conductor, fine wire


stranded with AWG measures
Special PVC core insulation with transparent
nylon skin
Black cores with continuous white
numbering
Green-yellow earth core in the outer layer
Cores stranded in layers with optimal
lay-lenghts
Fleece
1. Screening with special aluminium foil
2. Screening with braid of tinnedcopper
wires, optimal coverage, approx. 85%
Separator
Special PVC outer jacket
Sheath colour -black (RAL 9005) or orange
(RAL 2003)
With length marking in feet 

Self-extinguishing and flame retardant in


accordance with CSA FT4
The materials used in manufacture are free
of silicone, cadmium and substances that
impair paint wetting
UV-resistant
Tests 
UL:
TC-ER, WTTC 1000 V, MTW, NFPA 79 2007,
UL 1277, PLTC-ER (AWG 18 - AWG 12), ITC-ER
(AWG 18 - AWG 12) OIL RES I & II, 90 C dry
/ 75 C wet, Cold Bend Test -40C
Class 1 Div. 2 per NEC Art. 336, 392, 501
CSA:
c (UL) CIC-TC FT4,
AWM I/II A/B FT4 


Note

VFD = Variable Frequency Drive




Application
Flexible, extremly oil-resistant motor supply cable for modern servomotors; the double-screening with special aluminium foil (100% coverage)
and tinned copper braid (approx. 85% coverage) provides effective protection against electrical disturbance and the resultant failures.
Approved to NFPA 79 2007 for open, unprotected installation on cable trays and from cable trays to the machine. The special PVC sheath
is extremly resistant to oil, coolants and solvents and hence the perfect solution for industrial applications with open installation, installation
in pipes and in the earth.
EMC = Electromagnetic compatibility
To optimise EMC characteristics, we recommend a large contact area for the copper braiding around the entire circumference on both
ends.
= The product conforms to the EG Low-Voltage Directive 2006/95/EG


Dimensions and specifications may be changed without prior notice. (RN01)

N 137
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX 650 VFD EMC-preferred type, flexible motor power supply


cable with control cores, oil-resistant, NFPA 79 Edition 2007


Technical data

Cable structure

Properties

TPE motor supply cable according to


UL1277
Temperature range
Flexing -25C to +105C
Nominal voltage
TC 600 V
WTTC 1000 V
Test voltage
Power supply cores 4000 V
Control cores 2000 V
Minimum bending radius
Flexing 6x cable
Coupling resistance
Max. 250 Ohm/km

Tinned copper conductor, fine wire


stranded, with AWG measures
Special PVC core insulation with transparent
nylon skin
Black supply cores with continuous white
numbering
Green-yellow earth core in the outer layer
2 black control cores with marking 5
and 6
Control cores screened in pairs with
plastic-coated aluminium foil, tinned drain
wire
Control cores stranded in pairs and laid up
in layers with optimal lay-length with the
power supply cores
1. Screening with plastic-coated aluminium
foil
2. Screening from tinned Cu-braid, optimal
coverage approx. 85%
Separator
Special TPE outer jacket
Sheath colour - black (RAL 9005) or orange
(RAL 2003)
With length marking in feet

Self-extinguishing and flame retardant in


accordance with CSA FT4
The materials used in manufacture are free
of silicone, cadmium and substances that
impair paint wetting
UV-resistant
Tests
UL:
TC-ER, WTTC 1000 V, MTW, NFPA 79 2007,
UL 1277, PLTC-ER (AWG 18 - AWG 12), ITC-ER
(AWG 18 - AWG 12) OIL RES I & II, 90 C dry
/ 75 C wet
Class 1 Div. 2 per NEC Art. 336, 392, 501
Cold Bend Test -40C
CSA:
c (UL) CIC-TC FT4
AWM I/II A/B FT4


Note

VFD = Variable Frequency Drive

Application
Flexible, extremly oil-resistant motor supply cable for modern servomotors; the double-screening with special aluminium foil (100% coverage)
and tinned copper braid (approx. 85% coverage) provides effective protection against electrical disturbance and the resultant failures.
Approved to NFPA 79 2007 for open, unprotected installation on cable trays and from cable trays to the machine. The special PVC sheath
is extremly resistant to oil, coolants and solvents and hence the perfect solution for industrial applications with open installation, installation
in pipes and in the earth.

EMC = Electromagnetic compatibillity
To optimise EMC characteristics, we recommend a large contact area for the copper braiding around the entire circumference on both
ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Dimensions and specifications may be changed without prior notice. (RN01)

N 138
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPSERV 600 VFD EMC-preferred type, flexible motor


power supply cable, oil-resistant, NFPA 79 Edition 2007


Technical data

Cable structure

Properties

PVC motor supply cable according to


UL1277
Temperature range
-25C to +90C
Nominal voltage
TC 600 V
WTTC 1000 V
Test voltage 4000 V
Minimum bending radius
Flexing 5x cable
Permanently flexing 7,5 cable
Coupling resistance
Max. 250 Ohm/km

Tinned copper conductor, extra fine wire


stranded with AWG measures
Special PVC core insulation with transparent
nylon skin
Black cores with continuous white
numbering
Green-yellow earth core in the outer layer
Cores stranded in layers with optimal
lay-lenghts
Fleece
1. Screening with special aluminium foil
2. Screening with braid of tinned copper
wires, optimal coverage, approx. 85%
Separator
Special PVC outer jacket
Sheath colour - black (RAL 9005) or orange
(RAL 2003)
With length marking in feet

Self-extinguishing and flame retardant in


accordance with CSA FT4
The materials used in manufacture are free
of silicone, cadmium and substances that
impair paint wetting
UV-resistant
Tests
UL:
TC-ER, WTTC 1000 V, MTW, NFPA 79 2007,
UL 1277, PLTC-ER (AWG 18 - AWG 12), ITC-ER
(AWG 18 - AWG 12) OIL RES I & II, 90 C dry
/ 75 C wet, Cold Bend Test -40C
CSA:
c (UL) CIC-TC FT4,
AWM I/II A/B FT4


Note
VFD = Variable Frequency Drive


Application
Flexible, extremly oil-resistant motor supply cable for modern servomotors; the double-screening with special aluminium foil (100% coverage)
and tinned copper braid (approx. 85% coverage) provides effective protection against electrical disturbance and the resultant failures.
Approved to NFPA 79 2007 for open, unprotected installation on cable trays and from cable trays to the machine. The special TPE sheath is
extremly resistant to oil, coolants and solvents and hence the perfect solution for industrial applications with open installation, installation
in pipes and in the earth.
EMC = Electromagnetic compatibility
To optimise EMC characteristics, we recommend a large contact area for the copper braiding around the entire circumference on both
ends.
= The product conforms to the EG Low-Voltage Directive 2006/95/EG


Dimensions and specifications may be changed without prior notice. (RN01)

N 139
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPSERV 650 VFD EMC-preferred type, flexible motor power


supply cable with control cores, oil-resistant, NFPA 79 Edition 2007


Technical data

Cable structure

Properties

TPE motor supply cable according to UL


1277
Temperature range
Flexing -25C to +105C
Nominal voltage
TC 600 V
WTTC 1000 V
Test voltage
Power supply cores 4000 V
Control cores 2000 V
Minimum bending radius
Flexing 5x cable
Permanently flexing 7,5 cable
Coupling resistance
Max. 250 Ohm/km

Tinned copper conductor, fine wire


stranded, with AWG measures
Special PVC core insulation with transparent
nylon skin
Black supply cores with continuous white
numbering
Green-yellow earth core in the outer layer
2 black control cores with marking 5 and 6
Control cores screened in pairs with
plastic-coated aluminium foil, tinned drain
wire
Control cores stranded in pairs and laid up
in layers with optimal lay-length with the
power supply cores
1. Screening with plastic-coated aluminium
foil
2. Screening from tinned Cu-braid, optimal
coverage approx. 85%
Separator
Special TPE outer jacket
Sheath colour - black (RAL 9005) or orange
(RAL 2003)

Self-extinguishing and flame retardant in


accordance with CSA FT4
The materials used in manufacture are free
of silicone, cadmium and substances that
impair paint wetting
UV-resistant
Tests
UL:
TC-ER, WTTC 1000 V, MTW, NFPA 79 2007,
UL 1277, PLTC-ER (AWG 18 - AWG 12), ITC-ER
(AWG 18 - AWG 12) OIL RES I & II, 90 C dry
/ 75 C wet
Class 1 Div. 2 per NEC Art. 336, 392, 501
Cold Bend Test -40C
CSA:
c (UL) CIC-TC FT4
AWM I/II A/B FT4


Note
VFD = Variable Frequency Drive
with meter marking in feet


Application
Highly-flexible, extremly oil-resistant motor supply cable for modern servomotors; the double-screening with special aluminium foil (100%
coverage) and tinned copper braid (approx. 85% coverage) provides effective protection against electrical disturbance and the resultant
failures. Approved to NFPA 79 2007 for open, unprotected installation on cable trays and from cable trays to the machine. The special TPE
sheath is extremly resistant to oil, coolants and solvents and hence the perfect solution for industrial applications with open installation,
installation in pipes and in the earth.

EMC = Electromagnetic compatibillity
To optimise EMC characteristics, we recommend a large contact area for the copper braiding around the entire circumference on both
ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Dimensions and specifications may be changed without prior notice. (RN01)

N 140
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX-EMV-UV-2YSLCYK-J UL/CSA Motor


supply cable 0,6/1kV, for power supply connections to frequency converters, double
screened, meter marking.


Technical data

Cable structure

Properties

Special motor power supply cable for


frequency converters to Style 2570
Temperature range
flexing -5 C bis +70 C
fixed installation -40 C bis +70 C
Nominal voltage
VDE - U0/U 0,6/1 kV
UL - U 1000 V
Operating voltage, max.
A.C. and 3-phase 700/1200 V
DC operation 900/1800 V
Test voltage 2500 V
Insulation resistance
min. 200 MOhm x km
Coupling resistance
depending on the cross-section
max. 250 Ohm/km
Mutual capacitance
depending on the cross-section
core/core - 70 up to 250 nF/km
core/screen - 110 up to 410 nF/km
Minimum bending radius
fixed installation for outer :
up to 12 mm: 5x cable
>12 to 20 mm: 7,5x cable
>20 mm: 10x cable
free-movement for outer :
up to 12 mm: 10x cable
>12 to 20 mm: 15x cable
>20 mm: 20x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductor to


style2570
Polyethylene (PE) core insulation
Core colour: green-yellow, brown, black
and grey
Cores stranded in concentric layers
1. screening with special aluminum foil
2. screening with copper braiding, tinned
copper, coverage approx. 80%
Special PVC outer sheath, schwarz (RAL
9005)
with meter marking, change-over in 2011


Behavior in fire: Test according to


VDE0482-332-1-2, DIN EN60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Low mutual capacitance
PE-insulation secures a lower dielectric loss,
double potential strength, high longevity
and low screen-interference currents
Low coupling resistance for high
electromagnetic compatibility
Resistant to ultra violet rays
This enables an extremely concentric
structure
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
This screened motor supply cable with low
mutual capacitance of the single cores
because of the special PE core insulation
and low screen capacitance enable a
low-loss transmission of the power
compared to PVC-sheathed connecting
cables
Due to the optimal screening an
interference-free operation of frequency
converters is obtained

Application
This TOPFLEX-EMV-UV-2YSLCYK-J UL/CSA motor connection cable for the frequency converters secures the EMC in systems and buildings,
equipment with devices and machineries, which can emit electromagnetic interference fields that can impact the environment in an illegal
manner. It is used as a connection and connecting cable under average mechanical stress for fixed installations and sometimes for free
movement in dry, moist and wet rooms and outside. It is used in the automotive industry, food processing industry, transfer streets,
packaging industry, machine tools, handling equipment, in the industry it is used for pumps, fans, transport belts, etc.
Used in explosion proof areas.
EMC = Electromagnetic compatibility
The screen must be connected at both ends and ensure lare-area contact over the entire cable circumference for compliance with the
functional interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
22320
22321
22322
22323
22324
22325
22326
22327

4G1,5
4G2,5
4G4
4G6
4G10
4G16
4G25
4G35

Outer
Mutual capacitance
approx. mm Core / Core Core / Screen
approx. nF / approx. nF /
km
km
10,4
12,5
80
130
14,2
90
150
15,2
90
150
19,5
120
200
22,9
140
230
27,1
120
210
29,6
150
260

Coupling resistance
at 1 MHz
at 30 MHz
Ohm/km
Ohm/km

Power ratings **)


with 3 loaded cores
inAmperes

Cop.
weight
kg/km

Weight
approx.
kg/km

18
11
6
7
9
4
3

18
26
34
44
61
82
108
135

95,0
150,0
235,0
320,0
533,0
789,0
1236,0
1662,0

140,0
300,0
485,0
630,0
860,0
1290,0
1860,0
2610,0

210
210
150
180
190
95
85

AWG-No.

16
14
12
10
8
6
4
2

Continuation

N 141
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX-EMV-UV-2YSLCYK-J UL/CSA Motor


supply cable 0,6/1kV, for power supply connections to frequency converters, double
screened, meter marking.


Part no. No.cores x


cross-sec.
mm
22328
22329
22330
22331
22332
22333

4G50
4G70
4G95
4G120
4G150
4G185

Outer
Mutual capacitance
approx. mm Core / Core Core / Screen
approx. nF / approx. nF /
km
km
35,2
190
320
41,4
190
320
46,0
250
410
50,8
58,3
65,5

Coupling resistance
at 1 MHz
at 30 MHz
Ohm/km
Ohm/km

Power ratings **)


with 3 loaded cores
inAmperes

Cop.
weight
kg/km

Weight
approx.
kg/km

2
2
1

168
207
250
292
335
382

2345,0
3196,0
4316,0
5435,0
6394,0
7639,0

2950,0
3950,0
5300,0
6600,0
7040,0
8380,0

40
45
50

AWG-No.

1
2/0
3/0
4/0
300 kcmil
350 kcmil

Dimensions and specifications may be changed without prior notice. (RD01)

Tools
Cable shears
Box spanners
Strippers
Crimping tools
Pliers
Skinning knife

You can nd tools in our catalogue Cable Accessories.

N 142
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX-EMV-UV 2YSLCYK-J UL/CSA Motor


supply cable 0,6/1kV, for power supply connections to frequency converters, double
screened, meter marking.


Technical data

Cable structure

Properties

Special motor power supply cable for


frequency converters to Style 2570
Temperature range
flexing -5 C bis +70 C
fixed installation -40 C bis +70 C
Nominal voltage
VDE - U0/U 0,6/1 kV
UL - U 1000 V
Operating voltage, max.
A.C. and 3-phase 700/1200 V
DC operation 900/1800 V
Peak value 1700 V
Test voltage 2500 V
Insulation resistance
min. 200 MOhm x km
Coupling resistance
depending on the cross-section
max. 250 Ohm/km
Minimum bending radius
fixed installation for outer :
up to 12 mm: 5x cable
>12 to 20 mm: 7,5x cable
>20 mm: 10x cable
free-movement for outer :
up to 12 mm: 10x cable
>12 to 20 mm: 15x cable
>20 mm: 20x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductor to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Polyethylene (PE) core insulation
Core colour: black, brown, grey,
green-yellow (earth core divided into 3)
Cores stranded in concentric layers
3+3 core design
1. screening with special aluminum foil
2. screening with copper braiding, tinned
copper, coverage approx. 80%
Special PVC outer sheath, schwarz (RAL
9005)
with meter marking, change-over in 2011


Behavior in fire: Test according to


VDE0482-332-1-2, DIN EN60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
PE-insulation secures a lower dielectric loss,
double potential strength, high longevity
and low screen-interference currents
Low mutual capacitance
Meets EMC requirements according to
EN55011 and DINVDE0875 part11
Low coupling resistance for high
electromagnetic compatibility
Due to the optimal screening an
interference-free operation of frequency
converters is obtained
The 3 Plus-construction of motor power
supply cables features a symmetrical 3-core
design, improved in terms of EMC
characteristics comparing favorably with a
4-core version
The protective conductor PE, divided into
3 is uniformly stranded in the interstices
This enables an extremely concentric
structure
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
The minimum cross-section of 0,75 meets
the requirements of DINEN60204 part1
Resistant to ultra violet rays
This screened motor supply cable with low
mutual capacitance of the single cores
because of the special PE core insulation
and low screen capacitance enable a
low-loss transmission of the power
compared to PVC-sheathed connecting
cables.

Application
It is used as a connection and connecting cable under average mechanical stress for fixed installation and sometimes for free movement
in dry, moist and wet rooms and outside. It is used in the automotive industry, food processing industry, transfer streets, packaging industry,
machine tools, handling equipment, in the industry it is used for pumps, fans, transport belts and in air condition systems, etc.
Used in explosion proof areas.
EMC = Electromagnetic compatibility
The screen must be connected at both ends and ensure lare-area contact over the entire cable circumference for compliance with the
functional interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Continuation

N 143
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX-EMV-UV 2YSLCYK-J UL/CSA Motor


supply cable 0,6/1kV, for power supply connections to frequency converters, double
screened, meter marking.

Part no.
22193
22194
22195
22196
22197
22198
22199
22223
22224
22225
22226
22227
22228
22229
22230

No.cores x
cross-sec.
mm
( 3 x 1,5 + 3G0,25)
( 3 x 2,5 + 3G0,5)
( 3 x 4 + 3G0,75)
( 3 x 6 + 3G1,0)
( 3 x 10 + 3G1,5)
( 3 x 16 + 3G2,5)
( 3 x 25 + 3G4,0)
( 3 x 35 + 3G6,0)
( 3 x 50 + 3G10,0)
( 3 x 70 + 3G10,0)
( 3 x 95 + 3G16,0)
( 3 x 120 + 3G16,0)
( 3 x 150 + 3G25,0)
( 3 x 185 + 3G35,0)
( 3 x 240 + 3G42,5)

Outer
approx. mm
10,0
11,4
13,0
15,0
18,4
21,0
25,3
27,8
32,6
38,1
41,0
46,4
53,5
59,5
65,1

Coupling resistance
at 1 MHz
at 30 MHz
Ohm/km
Ohm/km
18
11
6
7
9
4
3
2
2
1

210
210
150
180
190
95
85
40
45
50

Power ratings **)


with 3 loaded cores
inAmperes
18
26
34
44
61
82
108
135
168
207
250
292
335
382

Cop.
weight
kg/km
86,0
144,0
224,0
298,0
491,0
723,0
1138,0
1535,0
2208,0
2871,0
3953,0
4836,0
5412,0
6969,0
8540,0

Weight
approx.
kg/km
140,0
220,0
323,0
420,0
615,0
819,0
1325,0
1718,0
2399,0
3056,0
4162,0
5075,0
6128,0
7189,0
9540,0

AWG-No.
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil

Dimensions and specifications may be changed without prior notice. (RD01)

Signal and power circular connectors


Series A, B, C, D, F and S
Tools
Accessories
Online congurator
Pre-assembled cables

You can nd signal and power circular connectors in our catalogue Cable Accessories.

N 144
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX-EMV-UV 2YSLC11Y-J UL/CSA Motor


supply cable 0,6/1kV, for power supply connections to frequency converters, double
screened, meter marking.


Technical data

Cable structure

Properties

Special PURmotor power supply cable for


frequency converters to UL AWMstyle
20234 and CSA AWM adapted to
DINVDE0250
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage
to UL 1000 V
to VDE U0/U 0,6/1 kV
A.c. test voltage, 50 Hz
3000 V
Mutual capacitance at 4 kHz,
according to different cross-sections
core/core 70 to 250 nF/km
core/screen 110 to 410 nF/km
Insulation resistance
min. 200 MOhm x km
Minimum bending radius
fixed installation for outer :
up to 12 mm: approx. 5x cable
>12 to 20 mm: approx. 7,5x cable
>20 mm: approx. 10x cable
free-movement for outer :
up to 12 mm: approx. 10x cable
>12 to 20 mm: approx. 15x cable
>20 mm: approx. 20x cable
Coupling resistance
max. 250 Ohm/km
Radiation-resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductor to


DINVDE0295 cl.5, BS6360 cl.5 or
IEC60228 cl.5
Polyethylen (PE) core insulation
Core colours: black, brown, grey,
green-yellow
Cores stranded in concentric layers
1. screening with special aluminium film
2. screening with copper braiding, tinned
copper, coverage approx. 80%
PUR-outer sheath
Sheath colour black (RAL 9005)
with meter marking, change-over in 2011


PUR outer sheath: low adhesion, flame


retardant, extremely abradion resistant,
halogen-free, resistant to UV, oil, hydrolysis
and microbial attack 
PUR sheath: self-extinguishing and flame
retardant, to VDE 0482-332-1-2, DIN EN
60332-1-2/IEC 60332-1( equivalent DIN VDE
0472 part 804 test method B)
Low mutual capacitance, to DINVDE0472
part504, test methodB
Features PE-insulation secures a lower
dielectric loss, double potential strength,
high longevity and low screen-interference
currents
Low mutual capacitance
Meets EMC requirements according to
EN55011 and DINVDE0875 part11
Low coupling resistance for high
electromagnetic compatibility
UV-resitant
Outdoor application
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
This screened motor supply cable with low
mutual capacitance of the single cores
because of the special PE core insulation
and low screen capacitance enable a
low-loss transmission of the power
compared to PVC-sheathed connecting
cables
Due to the optimal screening an
interference-free operation of frequency
converters is obtained


Application
This TOPFLEX-EMC-UV-2YSLC11Y-J UL/CSA motor power supply cable with PURouther sheathfor the frequency converters assures
electromagnetic compatibility in plants and buildings, facilities with units and operating equipment where the fields of electromagnetic
interference might cause adverse effects on the surroundings. As a supply and connecting cable for medium mechanical stresses in fixed
installations and forced movements in dry, moist and wet environments and for outdoor applications.Used in the automotive and food
industries, environmental technology, packaging industry, machine tools. Handling equipment, for SIMOVERT drives, they are particularly
suitable for use with industrial pumps, ventilators, conveyor belts and air-conditioning installations and similar applications.
Installation in hazardous areas.
EMC = Electromagnetic compatibility
The screen must be connected at both ends and ensure lare-area contact over the entire cable circumference for compliance with the
functional interference requirements of EN55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
22389
22390
22391
22392
22393

4G1,5
4G2,5
4G4
4G6
4G10

Outer
Mutual capacitance
approx. mm Core / Core Core / Screen
approx. nF / approx. nF /
km
km
10,3
70
110
12,3
80
130
13,9
90
150
15,3
90
150
19,5
120
200

Coupling resistance
at 1 MHz
at 30 MHz
Ohm/km
Ohm/km

Power ratings **)


with 3 loaded cores
inAmperes

Cop.
weight
kg/km

Weight
approx.
kg/km

18
11
6
7

21
31
40
52
72

95,0
150,0
235,0
320,0
533,0

230,0
300,0
485,0
630,0
860,0

210
210
150
180

AWG-No.

16
14
14
14
14

Continuation

N 145
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX-EMV-UV 2YSLC11Y-J UL/CSA Motor


supply cable 0,6/1kV, for power supply connections to frequency converters, double
screened, meter marking.

Part no. No.cores x


cross-sec.
mm
22394
22395
22396
22397
22398
22399
22566
22567
22568

4G16
4G25
4G35
4G50
4G70
4G95
4G120
4G150
4G185

Outer
Mutual capacitance
approx. mm Core / Core Core / Screen
approx. nF / approx. nF /
km
km
23,3
140
230
27,4
120
211
30,3
150
260
35,5
190
320
40,2
190
320
44,5
250
410
50,3
56,1
58,0

Coupling resistance
at 1 MHz
at 30 MHz
Ohm/km
Ohm/km

Power ratings **)


with 3 loaded cores
inAmperes

Cop.
weight
kg/km

Weight
approx.
kg/km

9
4
3
2
2
1

96
127
158
192
246
295
344
395
450

789,0
1180,0
1662,0
2345,0
3196,0
4316,0
5435,0
6394,0
7639,0

1290,0
1800,0
2610,0
2950,0
3950,0
5300,0
6600,0
7040,0
8380,0

190
95
85
40
45
50

AWG-No.

14
14
14
14
14
14
14
14
14

Dimensions and specifications may be changed without prior notice. (RD01)

Cable Glands
Cable glands for standard applications
Plastic Glands
Cable Glands of Brass
Accessories
Cable glands for special application conditions
for electromagnetic compatibility EMC
for rugged applications and special chemical resistance
for high temperature use
for explosive areas
for special mounting conditions
for special pressure conditions

You can nd cable glands in our catalogue Cable Accessories.

N 146
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX MOTOR EMV 1/1 triple-screened, low


capacitance, 80C 600V high flexible motor supply cable, meter marking


Technical data

Cable structure

Properties

Special PUR motor power supply cable for


frequency converter to ULAWM Style20234
and CSAAWM based on DINVDE0250
Temperature range
flexing -30 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage
acc. to UL 1000 V
acc. to VDE U0/U 0,6/1 kV
A.c. test voltage, 50 Hz
3000 V
Mutual capacitance at 4 kHz,
depending on conductor cross-section
core/core 70-250 nF/km
core/screen 110-410 nF/km
Insulation resistance
min. 200 MOhm x km
Minimum bending radius
fixed installation,
for outside to 12 mm = 5x cable
12 to 20 mm = 7,5x cable
> 20 mm = 10x cable
free-movement,
for outside to 12 mm = 10x cable
12 to 20 mm = 15x cable
> 20 mm = 20x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire in acc. with


DINVDE0295 cl.5 and IEC60228 cl.5
Special polyethylene (PE) core insulation
Core colours black, brown, grey
Green-yellow earth core
Cores stranded in layers
Screen of semi-conductive fleece,
aluminium-coated polyester film and
tinned copper braiding, coverage approx.
85%
PUR outer sheath
Sheath colour orange (RAL 2003) according
to DESINA
with meter marking, change-over in 2011


PUR outer sheath: low adhesion, flame


retardant, extremely abrasion resistant,
halogen-free, resistant to UV, oil, hydrolysis
and microbial attack
PUR sheath: self-extinguishing and flame
retardant according to VDE0482-332-1-2,
DIN EN60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
This screened motor power supply cable,
with low mutual capacitance because of
the special PE core insulation, enables
low-loss transmission of power compared
to PVC-sheathed power supply cables
The optimal triple screening enables
interference-free operation of frequency
converters
Optimum compliance with requirements
for electromagnetic compatibility (EMC)
due to the triple screening
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Tests
Low mutual capacitance: tested acc. to
DINVDE0472 part504, test methodB

Application
This TOPFLEX MOTOR EMV 1/1 two-approvals, triple-screened motor power supply cable for frequency converters provides outstanding
EMC in machines and systems.
Suitable as a supply and connecting cable for high mechanical stresses, in fixed installations and occasional free movements in dry, moist
and wet environments, as well as outdoors.
Areas of application include machine tools, processing and manufacturing machinery, machining centres, industrial robots, transfer lines,
handling equipment, etc.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
78377
78378
78379
78380
78381
78382
701308
78383
78384
78385
78386
78387
78388
78479

4G1,5
4G2,5
4G4
4G6
4G10
4G16
4G25
4G35
4G50
4G70
4G95
4G120
4G150
4G185

Outer
Mutual capacitance
approx. mm Core / Core Core / Screen
approx. nF / approx. nF /
km
km
11,5
70
110
13,5
80
130
15,8
90
150
17,8
90
150
21,6
120
200
25,4
120
210
31,0
140
230
33,0
150
260
39,0
190
320
45,0
190
320
50,1
250
410
54,2
61,3
64,2

Coupling resistance
at 1 MHz
at 30 MHz
Ohm/km
Ohm/km
18
11
6
7
9
4
3
2
2
1

210
210
150
180
190
95
85
40
45
50

Power ratings **)


with 3 loaded cores
inAmperes

Cop.
weight
kg/km

Weight
approx.
kg/km

18
26
34
44
61
82
108
135
168
207
250
292
335
382

95,0
150,0
235,0
320,0
533,0
789,0
1180,0
1662,0
2345,0
3196,0
4316,0
5435,0
6394,0
7639,0

230,0
300,0
485,0
630,0
860,0
1290,0
1800,0
2610,0
2950,0
3950,0
5300,0
6600,0
7040,0
8380,0

AWG-No.

16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil

Dimensions and specifications may be changed without prior notice.

N 147
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX-MOTOR-EMV 3/3 triple-screened, low


capacitance, 80C, 600V, PUR flexible motor supply cable, meter marking


Technical data

Cable structure

Properties

Special PUR motor power supply cable for


frequency converter to ULAWM Style20234
and CSAAWM based on DINVDE0250
Temperature range
flexing -30 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage
acc. to UL 1000 V
acc. to VDE U0/U 0,6/1 kV
A.c. test voltage, 50 Hz
3000 V
Mutual capacitance at 4 kHz,
depending on conductor cross-section
core/core 70-250 nF/km
core/screen 110-410 nF/km
Insulation resistance
min. 200 MOhm x km
Minimum bending radius
fixed installation,
for outside to 12 mm = 5x cable
>12 to 20 mm = 7,5x cable
>20 mm = 10x cable
free-movement,
for outside to 12 mm = 10x cable
>12 to 20 mm = 15x cable
>20 mm = 20x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire in acc. with


DINVDE0295 cl.5 and IEC60228 cl.5
Special polyethylene (PE) core insulation
Core colours black with imprint U1, V2, W3
Green-yellow earth core
Cores stranded in layers
Screen of semi-conductive fleece,
aluminium-coated polyester film and
tinned copper braiding, coverage approx.
85%
PVC outer sheath
Sheath colour orange (RAL 2003) according
to DESINA
with meter marking, change-over in 2011


PUR outer sheath: low adhesion, flame


retardant, extremely abrasion resistant,
halogen-free, resistant to UV, oil, hydrolysis
and microbial attack
PUR sheath: self-extinguishing and flame
retardant, test method B acc. to
DINVDE0472 part804 and IEC60332-1
This screened motor power supply cable,
with low mutual capacitance because of
the special PE core insulation, enables
low-loss transmission of power compared
to PVC-sheathed power supply cables
The optimal triple screening enables
interference-free operation of frequency
converters
Optimum compliance with requirements
for electromagnetic compatibility (EMC)
due to the triple screening
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Tests
Low mutual capacitance: tested acc. to
DINVDE0472 part504, test methodB
Special features:
Here the earth core cross-section is divided
into thirds, which lie in the interstices
between the power supply cores. Due to this
symmetrical construction, the PE insulation
and the triple screening, very low capacitance
and inductance are achieved. EMC
compatibility is considerably enhanced.



Note

All cables are also available in JB with


coloured cores according to VDE0295.


Application
This TOPFLEX MOTOR EMV 3/3 two-approvals, triple-screened motor power supply cable for frequency converters provides outstanding
EMC in machines and systems.
Suitable as a supply and connecting cable for high mechanical stresses, in fixed installations and occasional free movements in dry, moist
and wet environments, as well as outdoors.
Areas of application include machine tools, processing and manufacturing machinery, machining centres, industrial robots, transfer lines,
handling equipment, etc.
By dividing the earth core into thirds and dividing it evenly in the interstices between the power supply cores, a symmetrical structure has
been achieved. This results in improved EMC, capacitance and inductance compared to the 4-core version.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Continuation

N 148
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX-MOTOR-EMV 3/3 triple-screened, low


capacitance, 80C, 600V, PUR flexible motor supply cable, meter marking


Part no.
78614
78615
78616
78617
78618
78619
78620
78621
78622
78623
78624
78625
78626

No.cores x
cross-sec.
mm
3 x 1,5 + 3G0,25
3 x 2,5 + 3G0,5
3 x 4 + 3G0,75
3 x 6 + 3G1,0
3 x 10 + 3G1,5
3 x 16 + 3G2,5
3 x 25 + 3G4,0
3 x 35 + 3G6,0
3 x 50 + 3G16,0
3 x 70 + 3G10,0
3 x 95 + 3G16,0
3 x 120 + 3G16,0
3 x 150 + 3G25,0

Outer
approx. mm
10,4
12,1
13,9
15,5
19,5
22,5
28,6
29,6
35,7
43,0
47,0
52,0
58,0

Coupling resistance
at 1 MHz
at 30 MHz
Ohm/km
Ohm/km
18
11
6
7
9
4
3
2
2
1

210
210
150
180
190
95
85
40
45
50

Power ratings **)


with 3 loaded cores
inAmperes
18
26
34
44
61
82
108
135
168
207
250
292
335

Cop.
weight
kg/km
100,0
160,0
245,0
335,0
750,0
820,0
1180,0
1700,0
2400,0
3300,0
4500,0
5500,0
6260,0

Weight
approx.
kg/km
150,0
240,0
345,0
460,0
840,0
930,0
1425,0
1900,0
2650,0
4400,0
5300,0
6300,0
7200,0

AWG-No.
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil

Dimensions and specifications may be changed without prior notice.

Conduits
Corrugated tubes
for standard applications
for lager sizes
scissile corrugated tubes
conduit glands
High exible conduits
plastic conduits with spiral spring
metal conduits
conduits glands
Conduit for heavy mechanical duty
metal conduits with plastic sheat
plastic conduits
conduits glands for metal conduits

You can nd conduits in our catalogue Cable Accessories.

N 149
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX-MOTOR-EMV 103 low capacitance power


supply cable 0,6/1kV, increased ampacity, meter marking


Technical data

Cable structure

Properties

Special motor power supply cable for


frequency converters according to UL-AWM
style 21179
Temperature range
flexing -5 C to +70 C
fixed installation -40 C to +80 C
Permissible operating temperature
at conductor +90 C
Nominal voltage U0/U 600/1000 V
Max. operating voltage
A.C. and 3-phase 700/1200 V
DC operation 900/1800 V
Test voltage 2500 V
Insulation resistance
min. 200 MOhm x km
Coupling resistance
according to different cross-sections
max. 250 Ohm/km
Mutual capacitance
according to different cross-sections
core/core 70 to 250 nF/km
core/screen 110 to 410 nF/km
Minimum bending radius
fixed installation for outer :
up to 12 mm: approx. 5x cable
>12 to 20 mm: approx. 7,5x cable
>20 mm: approx. 10x cable
free-movement for outer :
up to 12 mm: approx. 10x cable
>12 to 20 mm: approx. 15x cable
>20 mm: approx. 20x cable
Radiation-resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductor to


DINVDE0295 cl.5, BS6360 cl.5 or
IEC60228 cl.5
Special-Polymer core insulation
Cores coded to DIN VDE 0293-308
Core colours:
above 5 cores color coded
7 cores black with numbering
Green-yellow earth-core
Cores stranded in concentric layers
1. screening with special aluminium film
2. screening with copper braiding, tinned
copper, coverage approx. 80%
Special PVC outer sheath, orange (RAL2003)
with meter marking, change-over in 2011


Behavior in fire: Test according to


DINVDE0482 / IEC60332-1 (equivalent to
DINVDE0472 part804) test typeB)
Low mutual capacitance, to DINVDE0472
part504, test methodB
Features Special-Polymer-insulation secures
a lower dielectric loss, double potential
strength, high longevity and low
screen-interference currents to include
increased current carrying capacity
Meets EMC requirements according to
EN55011 and DINVDE0875 part11
Low coupling resistance for high
electromagnetic compatibility
This screened motor supply cable with low
mutual capacitance of the single cores
because of the special Polymer core
insulation and low screen capacitance
enable a low-loss transmission of the power
compared to PVC-sheathed connecting
cables
Due to the optimal screening an
interference-free operation of frequency
converters is obtained
Design according to the requirements of
VdS 3501:2006-04
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Application
This UL/CSA motor power supply cable for the frequency converters assures electromagnetic compatibility in plants and buildings, facilities
with units and operating equipment where the fields of electromagnetic interference might cause adverse effects on the surroundings. As
a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments.
Used in the automotive and food industries, environmental technology, packaging industry, machine tools. Handling equipment, for SIMOVERT
drives, they are particularly suitable for use with industrial pumps, ventilators, conveyor belts and air-conditioning installations and similar
applications.
Installation in hazardous areas.
EMC = Electromagnetic compatibility
The screen must be connected at both ends and ensure lare-area contact over the entire cable circumference for compliance with the
functional interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
22689
3G1,5
22690
4G1,5
22691
5G1,5
22692
7G1,5
22693
3G2,5
22694
4G2,5
22695
5G2,5
22696
7G2,5
22697
4G4

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
9,4
72,0
200,0
10,4
95,0
230,0
11,2
117,0
258,0
13,2
148,0
281,0
11,2
137,0
270,0
12,5
150,0
300,0
13,5
200,0
352,0
16,0
230,0
473,0
14,2
235,0
485,0

AWG-No.
16
16
16
16
16
16
16
16
16


Part no. No.cores x
cross-sec.
mm
22698
5G4
22699
7G4
22700
4G6
22701
5G6
22702
7G6
22703
4G10
22704
5G10
22705
4G16
22706
4G25

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
15,4
321,0
567,0
18,2
352,0
603,0
15,2
320,0
633,0
16,8
439,0
679,0
20,0
501,0
771,0
19,5
533,0
860,0
21,6
711,0
1029,0
23,1
789,0
1290,0
27,1
1236,0
1862,0

AWG-No.
16
16
16
16
16
16
16
16
16

Dimensions and specifications may be changed without prior notice. (RN07)

N 150
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

VERTEILERFLEX two-approvals sensor actuator and


distributor cables PVC, PUR, PVC/PUR


Technical data

Cable structure

Properties

Special PVC or PUR sheath acc. to


UL Style 2464 for PVC, or
UL Style 20233 for PUR
Temperature range
flexing -5 C to +80 C
fixed installation -30 C to +80 C
Nominal voltage 300/500 V
A.c. test voltage, 50 Hz
to 0,25 mm2 1200 V
from 0,34 mm2 2000 V
Minimum bending radius
Sensorflex Two approvals PVC
approx. 7,5x cable
Sensorflex Two approvals PUR
approx. 15x cable

PVC cables
Bare copper, fine wire in acc. with
DINVDE0295 cl.5 or IEC60228 cl.5
PVC core insulation, core colours see below
Special PVC
PUR cables
Bare copper, ultra-fine wire conductors
acc. to DINVDE0295 cl.6 and/or IEC60228
cl.6
PVC core insulation
Core colours see below
PUR sheath
Part Nos. 79907, 75642, 79850
Construction like SENSORFLEX
two-approvals, except
with polypropylene core insulation


PVC cables
Extensively oil resistant.
Chemical Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
PUR cables
Low adhesion, extremely abrasion resistant,
resistant to hydrolysis and microbial attack
Special feature
The cables with the highly flexible stranded
conductor, cl. 6, are suitable for drag chain
applications
The types with PVC/PUR sheath material
have a PVC inner sheath, with a PUR sheath
applied over it by means of coextrusion


Note

All additional cross-sections, also with


UL/CSA approval, are available on request.


Application
For decentralised installation and control technology.
These cables are used in connector systems for sensors and actuators.
In combination with injected circular connectors and installed actuator-sensor boxes, they constitute an important connecting element
between the periphery and the PLC in production systems.
The assembled cables offer attractive opportunities for reducing costs, not only in the field of automation technology, but also in the entire
manufacturing industry.
While previously it was necessary to carry out time-consuming wiring of switchgear cabinets and machines, now field bus technology has
made it possible to move the periphery interfaces from the switchgear cabinets to the machines and systems.
Moving the I/O points to the system periphery enables significant reductions in installation costs.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


SENSORFLEX 2-APPROVALS
Part no.

78284
79907
78286
76345
76347
76348
76349
79850
78287
78288
76351
73571
75642

Jacket colour
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Black RAL9005

Cable structure
No.cores x
cross-sec.
mm
3x0,25
4x0,25
6x0,25
3x0,34
4x0,34
5G0,34
5G0,34
5G0,34
5G0,34
3G0,75
3G0,75
3G0,75
3G0,75

Jacket
material

Core colours

PUR
PUR
PVC
PVC
PVC
PVC/PUR
PVC/PUR
PUR
PVC/PUR
PUR
PVC
PVC
PUR

brown, blue, black


brown, blue, black, white
brown, blue, black, white, grey, pink
brown, blue, black
brown, blue, black, white
brown, blue, black, white, green-yellow
brown, blue, black, white, green-yellow
brown, blue, black, white, green-yellow
JZ, black with numbering + greenyellow
JZ, black with numbering + greenyellow
brown, blue, green-yellow
JZ, black with numbering + greenyellow
JZ, black with numbering + greenyellow

Fine
wire

X
X
X

X
X

High
flex **
X
X
X
X
X
X
X
X

Outer
approx.
mm
4,4
4,7
5,2
4,9
5,2
5,9
5,9
5,9
5,9
5,9
6,7
6,7
5,9

Cop.
weight
kg/km
7,2
9,6
14,4
9,8
13,1
16,4
16,4
16,4
16,4
21,6
28,8
21,6
21,6

Weight
approx.
kg/km
18,0
18,0
36,0
30,0
43,0
54,0
54,0
54,0
54,0
58,0
88,0
58,0
58,0

AWG-No.

24
24
24
22
22
22
22
22
22
18
18
18
18

Continuation

N 151
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

VERTEILERFLEX two-approvals sensor actuator and


distributor cables PVC, PUR, PVC/PUR
SENSORFLEX 2-APPROVALS
Part no.

74551
78289
78290
77352
76350
78291
73587

Jacket colour
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Black RAL9005
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001

Cable structure
No.cores x
cross-sec.
mm
4G0,75
4G0,75
2x1
2x1
11G1
2x1,5
3G1,5

Jacket
material

Core colours

PUR
PVC/PUR
PVC
PVC
PVC/PUR
PVC
PVC

JZ, black with numbering + greenyellow


JZ, black with numbering + greenyellow
black with number 1-2
black with number 1-2
black with number 1-8, bn, bu, gn, ye
brown, blue
brown, blue, green-yellow

Jacket
material

Core colours

PVC/PUR

brown, blue, green-yellow, white, green,


yellow, grey
brown, blue, green-yellow, white, green,
yellow, grey, pink, red
white, red-blue, green, wh-green, yellow,
brown-green, gy-pink, brown, blue,
green-yellow
brown, blue, green-yellow, white, green,
yellow, grey, pink, red, black, violet
brown, blue, gnye, gnwh, white, rdbu, green,
whgn, yellow, bngn, grey, whye, pink, yebn,
red
bn, bu, gnye, gnwh, wh, rdbu, gn, whgn, ye,
bngn, gy, whye, pk, yebn, rd, whgy, bk, gybn,
vt

Fine
wire
X
X
X
X
X
X

High
flex **
X

Outer
approx.
mm
6,9
7,0
7,2
7,2
12,0
6,8
6,9

Cop.
weight
kg/km
29,0
29,0
19,2
19,2
105,6
29,0
44,0

Weight
approx.
kg/km
66,0
66,0
56,0
56,0
225,0
75,0
94,0

Outer
approx.
mm
8,7

Cop.
weight
kg/km
35,0

Weight
approx.
kg/km
82,0

AWG-No.

18
18
17
17
17
16
16

Verteilerflex 2-APPROVALS
Part no.

Jacket colour

Cable structure
No.cores x
cross-sec.
mm
4G0,34

76352

Grey RAL 7001

76353

Grey RAL 7001

6G0,34

PVC/PUR

75614

Grey RAL 7001

8G0,34

PUR

76354

Grey RAL 7001

8G0,34

PVC/PUR

76355

Grey RAL 7001

12G0,34

PVC/PUR

76356

Grey RAL 7001

16G0,34

PVC/PUR

Fine
wire

High
flex **
X
X

AWG-No.

22

9,1

42,0

106,0

22

10,0

65,0

143,0

22

9,1

48,0

110,0

22

10,3

61,0

138,0

22

10,5

74,0

170,0

22

Dimensions and specifications may be changed without prior notice.

N 152
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL BS 5308-1
HELUKABEL BS 5308-2
HELUKABEL BS 5467
HELUKABEL BS 6724
Photo: HELUKABEL

Cables to British Standard

N 153
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL BS 5308 Part 1 Instruments cable,


core insulation PE or XLPE


Technical data

Cable structure

Note

Instrument cable acc. to British Standard


5308 Part 1
Temperature range
fixed installation -20 C to +65 C
Nominal voltage
Uo/U 300/500V
Minimum bending radius
fixed installation
5x external (Type 1)
6x external (Types 2+3)

Copper conductor, single-, multiple-, or


fine-wire acc. to BS 6360
Conductor cross-sections from 0,5 mm
to 1,5 mm
Core insulation
- Polyethylene acc. to BS 6234 Type 03 or
- XLPE (cross-linked polyethylene for LSZH
cable)
Cores stranded in pairs with optimal
lay-length,
Lay-length smaller than 100 mm
Number of pairs: 1,2,5,10,15,20,30,50
Pairs individually not screened or screened
Pairs stranded in layers
Wrapping with aluminium/polyester foil,
on request
Type 1
Flame retardant PVC outer sheath or LSZH
Type 2
Extruded polyethylene inner sheath, steel
wire armouring Flame retardant PVC outer
sheath or LSZH
Type 3
PVC inner sheath, steel wire armouring,
PVC outer sheath
Sheath colour black or blue

As a result of a wide range of cables and wires


according to British Standard, you can find
following only a small selection of types.
For request about British Standard cables
please contact us under
Ph. 004971509209-786
Fax 004971509209-148

Application

As measurement and control cables in power plants and industrial plants, and in the petrochemical industry.
Example
BS 5308 P1 T1 CU / PE / CAM / PVC = Overall screening, jacket PVC
BS 5308 P1 T2 CU / XLPE / IAM / CAM / LSZH / SWA / LSZH = Pair screened, Overall screening, galvanic round steel wire, halogen free


Dimensions and specifications may be changed without prior notice.

N 154
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL BS 5308 Part 2 Instruments cable, core insulation


PVC


Technical data

Cable structure

Note

Instrument cable acc. to


British Standard 5308 Part 2
Temperature range
fixed installation -20 C to +65 C
Nominal voltage
U0/U 300/500V
Minimum bending radius
fixed installation
5x external (Type 1)
6x external (Types 2)

Copper conductor, single-, multiple-, or


fine-wire acc. to BS 6360
Conductor cross-sections from 0,5 mm
to 1,5 mm
Core insulation
- PVC acc. to BS 6746
Cores stranded in pairs with optimal
lay-length,
Lay-length smaller than 100mm
Number of pairs: 1,2,5,10,20,30,50
Pairs individually not screened or screened
Pairs stranded in layers
Wrapping with aluminium/polyester foil,
on request
Type 1
Flame retardant PVC outer sheath
Type 2
Extruded PVC inner sheath, steel wire
armouring
Flame retardant PVC outer sheath
Sheath colour black or blue

As a result of a wide range of cables and wires


according to British Standard, you can find
following only a small selection of types.
For request about British Standard cables
please contact us under
Ph. 004971509209-786
Fax 004971509209-148

Application
As measurement and control cables in power plants and industrial plants, and in the petrochemical industry.
Example
BS 5308 P2 T2 CU / PVC / CAM / PVC / SWA / PVC = Overall screening, steel wire armouring


Dimensions and specifications may be changed without prior notice.

N 155
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL BS 5467 High voltage cable 0,6/1kV, armoured, sheath PVC




Technical data

Cable structure

Properties

Special power cable acc. to British Standard


5467
Temperature range
flexing 0 C to +90 C
fixed installation -15 C to +90 C
Nominal voltage
U0/U 0,6/1 kV
Minimum bending radius
fixed installation 6x external

Bare copper conductor acc. to BS 6360 cl.2


Core insulation of cross-linked polyethylene
Core identification
1-core - brown
2-core - brown, blue
3-core - brown, blue, grey
4-core - brown, black, grey, blue
5-core and up with numbering
Cores stranded layers
PVC-Inner sheath
Amouring of galvanized steel wire
PVC-Outer sheath
Sheath colour black

Reaction to fire tested acc. to IEC 60332-1,


BS 4066-1


Note

As a result of a wide range of cables and wires


according to British Standard, you can find
following only a small selection of types.
For request about British Standard cables
please contact us under
Ph. 004971509209-786
Fax 004971509209-148

Application
As a control and power cable in industrial enviroments. Thanks to the amouring of galvanized steel wire, can be used anywhere that a high
level of mechanical protection is required. Suitable for use outdoors and in the earth.
Example
BS 5467 CU / XLPE / PVC / AWA / PVC = Singlecore
BS 5467 CU / XLPE / PVC / SWA / PVC = Multicore


Dimensions and specifications may be changed without prior notice.

N 156
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL BS 6724 High voltage cable 0,6/1kV, armoured, halogen-free




Technical data

Cable structure

Properties

Special power cable acc. to British Standard


6724
Temperature range
flexing 0 C to +90 C
fixed installation -20 C to +90 C
Permissible operating temperature
at conductor +90 C
Nominal voltage
U0/U 0,6/1 kV
Minimum bending radius
fixed installation 6x external

Bare copper conductor acc. to BS 6360 cl.2


Core insulation of cross-linked polyethylene
Core identification
1-core - brown
2-core - brown, blue
3-core - brown, black, grey
4-core - brown, black, grey, blue
5-core and up with numbering
Cores stranded layers
Inner sheath LSHF mix
Amouring of galvanized steel wire
Outer sheath LSHF mix
Sheath colour black

Reaction to fire tested acc. to IEC 60332-3,


BS 4066-1


Note

As a result of a wide range of cables and wires


according to British Standard, you can find
following only a small selection of types.
For request about British Standard cables
please contact us under
Ph. 004971509209-786
Fax 004971509209-148

Application
Unlike power cables acc. to BS 5467, these are LSHF (Low Smoke Halogen Free). Used anywhere where in case of fire damage to human life
and material assets must be prevented, e.g. in industrial plants, airports, underground railways and tunnels.
Example
BS 5467 CU / XLPE / LSZH / AWA / LSZH = Singelcore
BS 5467 CU / XLPE / LSZH / SWA / LSZH = Multicore


Dimensions and specifications may be changed without prior notice.

N 157
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Infrastructure Cables and Wires

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Installation Cables

O1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Installation Cables
The most important cable for todays electricians
are NYM, (N)YM(St)Y, NHXMH etc. It is reassuring that
HELUKABEL takes care that cables are always
available at the right price, in the required quantity
and that cable can be supplied ex stock from all
4 HELUKABEL stocks.
Consequently there are no delays in delivery to the
building-site and no extra expense are incurred
by utilizing alternative sizes. Our own transports
deliver the required coils and drums immediately
to the customer. The environmentally friendly
packaging poses no waste disposal problems.
Maybe you can complete your next cable order
with corresponding accessories which you can
nd in our latest accessories catalogue. We supply
glands, identication materials, nylon binders, etc.
ex stock. You can nd our complete accessories
program in our latest accessories catalogue.

O2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description
YV-Equipment Wires / YR-Bell Sheathed Cables,according to VDE 0812............................................................................................
NYM-J/-O PVC-Sheathed Cable,VDE approved............................................................................................................................

(N)YM(St)-J PVC-sheathed cable,screened...........................................................................................................................................

(N)HMH-O,halogen-free for fixed installation, emission-free, 300/500V................................................................................................................

(N)HMH-J,halogen-free for fixed installation, emission-free, 300/500V.................................................................................................................


NHXMH-O/-J,halogen-free plastic sheathed cable 300/500 V, VDE approved....................................................................................................

Page
O 4
O 5
O 6
O 7
O 8
O 9

O3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

YV-Equipment Wires / YR-Bell Sheathed


Cables according to VDE 0812


Technical data
YR-Bell Sheathed Cables
Adapted to DIN VDE 0812
Minimum bending radius
15x cable
YV-Equipment Wires
Equipment wires with PVC core insulation
to DIN VDE 0812
Temperature range
flexing -5C to +70C
fixed installation -30C to +70C
Electrical characteristics

Cable structure
YV-Equipment Wires
Solid, tinned copper conductor
0,3 to 1,8 mm
PVC core insulation, YI3 to DINVDE0207
part4
Mono or twin colour wires, twin colour
wires have a base colour with the second
colour superimposed in ring form
Colour code to DIN47002
YR-Bell Sheathed Cables
Bare copper conductor, solid 0,8mm
Cores stranded in layer
Colour identification code see Technical
Informations
PVC-Outer jacket, white


Properties
YV-Equipment Wires
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Installation notes
The equipment wires are to be so uncoiled
from drums or coils so that no kinks or
twisting torsional stress can be occured.
Those are allowed to install as
self-supporting shaped wires
independently ensuring the
free-movements so as to gain a
compensating bending.
These are used without any mechanical
stress, pull, pressure, abrasion and notch
Several equipment wires are used together
in form of a bunch.
The insulating coverings are not be cut
through the binding materials.
The binding materials must be
nonconductive and not allowed to swell or
shrink in humidity.
During the soldering process without
jointing clamp, the soldering period is to
be shortened so that the insulating
covering should not be shrinked or injured.

Application
YV-Equipment Wires
Single core cables for use in small apparatus, switching and intercom system and for data transmission. These cables are not allowed for the
installation of heavy current operation. Equipment wire are used for wiring to the switchbords, amplifiers and dial intercommunicating
systems, measuring instruments, telephone exchange, clock centrals and data processing apparatus etc.
These wires are not permitted to apply outside of equipment for high power ratings.
YR-Bell Sheathed Cables
For different applications up to max. 100 V operating voltage, for fixed installation above and beneath plaster.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


YV-Equipment Wires
Part no.
28900
28901
28902
28903
28904
28905
28906
28907
28908
28909
28910
28911
28912
28913
28914
28915
28916
28917
28918

No.cores x
cond. / core
mm
1 x 0,3 / 0,7
2 x 0,3 / 0,7
3 x 0,3 / 0,7
1 x 0,4 / 0,8
2 x 0,4 / 0,8
3 x 0,4 / 0,8
1 x 0,5 / 0,9
2 x 0,5 / 0,9
3 x 0,5 / 0,9
4 x 0,5 / 0,9
1 x 0,8 / 1,4
2 x 0,8 / 1,4
3 x 0,8 / 1,4
4 x 0,8 / 1,4
1 x 1 / 1,8
2 x 1 / 1,8
3 x 1 / 1,8
1 x 1,4 / 2,2
1 x 1,8 / 2,8

Outer
approx.
mm
0,7
1,4
1,6
0,8
1,6
1,8
0,9
1,8
2,0
2,2
1,4
2,8
3,0
3,4
1,8
3,6
4,0
2,2
2,8

Cop.
weight
kg/km
0,7
1,4
2,1
1,3
2,5
3,8
2,0
3,9
5,9
7,9
5,0
10,0
15,0
20,0
7,9
16,0
24,0
15,0
25,0

Weight
approx.
kg/km
1,2
2,4
3,6
1,8
3,6
5,4
2,5
5,0
7,5
10,0
6,0
12,0
18,0
24,0
10,0
20,0
30,0
17,0
27,5

YR-Bell Sheathed Cables


Part no.
28919
28920
28921
28922
28923
28924
28925
28926
28927
28928

No.cores x
cond. / core
mm
2 x 0,8 / 1,4
3 x 0,8 / 1,4
4 x 0,8 / 1,4
5 x 0,8 / 1,4
6 x 0,8 / 1,4
8 x 0,8 / 1,4
10 x 0,8 / 1,4
12 x 0,8 / 1,4
16 x 0,8 / 1,4
24 x 0,8 / 1,4

Outer
approx.
mm
4,0
4,4
4,9
5,3
5,8
6,5
7,6
7,7
8,6
10,5

Cop.
weight
kg/km
9,6
14,4
19,2
24,0
28,8
38,0
48,0
58,0
77,0
115,0

Weight
approx.
kg/km
27,0
33,0
41,0
48,0
56,0
70,0
84,0
98,0
124,0
188,0

Dimensions and specifications may be changed without prior notice. (RO01)

O4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NYM-J/-O PVC-Sheathed Cable VDE approved




Technical data

Cable structure

Properties

PVC-sheathed cable to DINVDE0250


part204
Temperature range
flexing +5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage
U0/U 300/500 V
Test voltage 2000 V
Minimum bending radius
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Caloric load values
see Technical Informations

Solid or stranded, plain copper conductor


to DINVDE0295 cl.1 or cl.2, BS6360 cl.1
or cl.2 and IEC60228 cl.1 or cl.2
PVC core insulation, TI1 to DINVDE0281
part1
Colour coded to DINVDE0293-308
Cores stranded in layer
Special PVC outer sheath TM1, to
DINVDE0281 part1
Jacket colour grey (RAL7035)


PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)


Note

re = round conductor, single-wire;


rm = round conductor, multiple-wire.
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
For industrial- and wiring purposes.
Usable in the open, in dry, damp and wet environments in the open and concealed, as well as in masonry and in beton, not suitable for
imbedding in solidified- or compressed-concrete. Outdoor usage is only possible, as long as the cable is protected against direct sunlight.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
39050
39001
39006
39056
39007
39058
39009
39066
39017
39072
39023
39076
39077
39055
39024
39057
39008
39059
39010
39067
39018
39075
39051
39002
39074
39060
39011
39068
39019
39052
39003
39078

No.cores x
cross-sec.
mm
1G1,5
re
1x1,5
re
2x1,5
re
3G1,5
re
3x1,5
re
4G1,5
re
4x1,5
re
5G1,5
re
5x1,5
re
7G1,5
re
7x1,5
re
10G1,5 re
12G1,5 re
1G2,5
re
1x2,5
re
3G2,5
re
3x2,5
re
4G2,5
re
4x2,5
re
5G2,5
re
5x2,5
re
7G2,5
re
1G4
re
1x4
re
3G4
re
4G4
re
4x4
re
5G4
re
5x4
re
1G6
re
1x6
re
3G6
re

Outer
Cop.
approx. mm weight
kg/km
5,4
14,4
5,4
14,4
8,7
29,0
9,1
43,0
9,1
43,0
9,8
58,0
9,8
58,0
10,3
72,0
10,3
72,0
11,5
101,0
11,5
101,0
13,8
144,0
14,4
173,0
6,0
24,0
6,0
24,0
10,4
72,0
10,4
72,0
11,3
96,0
11,3
96,0
12,0
120,0
12,0
120,0
13,2
168,0
6,6
38,0
6,6
38,0
12,0
115,0
13,0
154,0
13,0
154,0
14,5
192,0
14,5
192,0
7,2
58,0
7,2
58,0
13,0
173,0

Weight
approx.
kg/km
40,0
40,0
170,0
135,0
135,0
160,0
160,0
190,0
190,0
235,0
235,0
330,0
405,0
70,0
70,0
190,0
190,0
230,0
230,0
270,0
270,0
342,0
80,0
80,0
258,0
330,0
330,0
410,0
410,0
105,0
105,0
320,0

AWG-No.
16
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14
14
12
12
12
12
12
12
12
10
10
10


Part no.
39061
39012
39069
39020
39053
39004
39062
39013
39070
39021
39054
39005
39063
39014
39071
39022
39079
39064
39015
39073
39065
39016

No.cores x
cross-sec.
mm
4G6
re
4x6
re
5G6
re
5x6
re
1G10
re
1x10
re
4G10
re
4x10
re
5G10
re
5x10
re
1G16
rm
1x16
rm
4G16
rm
4x16
rm
5G16
rm
5x16
rm
1G25
rm
4G25
rm
4x25
rm
5G25
rm
4G35
rm
4x35
rm

Outer
Cop.
approx. mm weight
kg/km
15,1
230,0
15,1
230,0
16,1
288,0
16,1
288,0
8,4
96,0
8,4
96,0
17,6
384,0
17,6
384,0
19,2
480,0
19,2
480,0
9,9
154,0
9,9
154,0
21,3
614,0
21,3
614,0
23,4
768,0
23,4
768,0
12,0
240,0
25,8
960,0
25,8
960,0
28,7
1200,0
28,5
1344,0
28,5
1344,0

Weight
approx.
kg/km
460,0
460,0
540,0
540,0
155,0
155,0
680,0
680,0
850,0
850,0
230,0
230,0
1048,0
1048,0
1280,0
1280,0
325,0
1649,0
1649,0
1970,0
2000,0
2000,0

AWG-No.
10
10
10
10
8
8
8
8
8
8
6
6
6
6
6
6
4
4
4
4
2
2

Dimensions and specifications may be changed without prior notice. (RO01)

O5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

(N)YM(St)-J PVC-sheathed cable screened




Technical data

Screened PVC-sheathed cable


Adapted to DINVDE0250 part204/209
VDE production accessment available
Direct current resistance
to DINVDE0295
Temperature range
flexing +5 C to +70 C
fixed installation -40 C to +70 C
4IVQMWWMFPI working temperature
at the conductor +70 C
Nominal voltage U0/U 300/500 V
Test voltage 2000 V
Power rating according
to VDE0100
Minimum bending radius
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Cable structure

Properties

Solid plain copper conductor to


DINVDE0295 cl.1, BS6360 cl.1 and
IEC60228 cl.1
Special PVC core insulation TI1, to
DINVDE0281 part1colour code to
DINVDE0293-308
Cores stranded in layer
Plastic filled inner sheath
Coated aluminium foil screening
Solid copper drain-wire, tinned
Special PVC outer sheath TM1, to
DINVDE0281 part1
Jacket colour grey (RAL7035)


PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)


Note

re = round solid core;


rm = stranded core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
These installation cables are made for an effective range of electromagnetic interference alternating fields by a static screen. This screening
is specially used for the installation in computer sector, hospitals or industry measuring observation points with measuring instruments
which are sensitive to interferences.
These cables are also ideal for installations in the living rooms of those peoples who are extreme sensitive to radiation. The cable is suitable
for laying on, in and under plaster in dry and damp places as well as in concrete and masonry (a direct laying in shaked or stamped concrete
is excluded).
Outdoor laying only is possible if the cable is not exposed to direct sunlight or if the cable is layed in cable conduits. Use in dangerous areas
is not allowed.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
43050
3G1,5
43051
4G1,5
43052
5G1,5
43053
7G1,5
43054
3G2,5
43055
4G2,5
43056
5G2,5
43057
3G4
43058
4G4
43059
5G4
43060
3G6
43061
4G6
43062
5G6

Drainwire
mm
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
10,5
51,0
154,0
11,5
63,0
184,0
12,0
80,0
208,0
13,0
106,0
250,0
12,0
80,0
217,0
13,0
104,0
256,0
13,5
128,0
280,0
13,5
123,0
228,0
14,5
159,0
359,0
16,5
200,0
440,0
15,0
187,0
378,0
16,5
235,0
477,0
17,5
293,0
565,0

AWG-No.
16
16
16
16
14
14
14
12
12
12
10
10
10


Part no. No.cores x
cross-sec.
mm
43063
5G10
43064
5G16
rm
43065
5G25
rm

Drainwire
mm
1,5
2,5
2,5

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
21,5
485,0
840,0
26,0
773,0
1353,0
31,5
1205,0
2017,0

AWG-No.
8
6
4

Dimensions and specifications may be changed without prior notice. (RO01)

O6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

(N)HMH-O halogen-free for fixed installation, emission-free, 300/500V




Technical data

Cable structure

Properties

Plastic-sheathed cable, halogen-free, for


fixed installation
To DINVDE0250 part215
4IVQMWWMFPI working temperature
at the conductor +70 C
Nominal voltage U0/U 300/500 V
Max. voltage for equipment Um 550 V
Power rating
in accordance with DINVDE0298 part4,
tables3 and 4, analogous for NYM, taking
the type of installation and the appropriate
factors for differing ambient temperatures
and build-up of cables
rated short-circuit current of density acc.
to DINVDE0298 part4 table15
fuse rating according to DINVDE0100
part430
Caloric load values
see Technical Informations

Bare Cu conductor, solid or stranded on


the basis of DINVDE0250 part204 with the
following modifications:
Core insulation of halogen-free
thermoplastic polymer compound with
optimum wall thickness
Colour coded to DINVDE0293-308
for 1 core cable
core colour black
Cores stranded in layer
Extruded core insulation, halogen-free
Outer jacket of non-cross-linked,
halogen-free thermoplastic polymer
compound
Jacket colour light-grey (RAL7035)


Corrosive nature of combustion gases


(halogen-free verification)
testing acc. to VDE0482part267,
DINEN50267-2-2, IEC60754-2, HD602
(equivalent DINVDE0472 part813)
Behaviour in case of fire
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Low smoke
testing acc. to DINVDE0472 part818


Note

re = round conductor, single-wire;


rm = round conductor, multiple-wire;
x = without green-yellow earth core.
O-version: single-core conductor with black
core insulation. Cables between two and
seven cores are without green-yellow core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
This plastic-sheathed cable of defined behaviour in case of fire is used for installations in residential dwellings, public buildings as well as in
industrial constructions.
Suitable for applications in dry, damp or wet environments for installation above, on, in and beneath plaster, as well as in masonry and
concrete walls, not however for embedding in vibration, compacted or tamped concrete.
The cable is also approved for outdoor applications provided these are not exposed to direct sunlight radiation. Installation of this cable in
earth or in water is not permitted.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
51970
51976
51981
51983
51991
51971
51977
51982
51984
51972
51978
51985
51973
51979
51986

No.cores x
cross-sec.
mm
1x1,5
re
2x1,5
re
3x1,5
re
4x1,5
re
7x1,5
re
1x2,5
re
2x2,5
re
3x2,5
re
4x2,5
re
1x4
re
2x4
re
4x4
re
1x6
re
2x6
re
4x6
re

Outer
Cop.
approx. mm weight
kg/km
8,3
14,4
8,9
29,0
9,2
43,0
9,9
58,0
11,5
101,0
9,0
24,0
10,0
48,0
10,6
72,0
11,0
96,0
9,5
38,0
11,5
77,0
13,4
154,0
10,0
58,0
12,4
115,0
15,9
230,0

Weight
approx.
kg/km
39,0
82,0
92,0
115,0
167,0
47,0
110,0
128,0
152,0
62,0
160,0
244,0
83,0
208,0
345,0

AWG-No.
16
16
16
16
16
14
14
14
14
12
12
12
10
10
10


Part no.
51974
51980
51987
51975
51988
51989
51990

No.cores x
cross-sec.
mm
1x10
re
2x10
re
4x10
re
1x16
rm
4x16
rm
4x25
rm
4x35
rm

Outer
Cop.
approx. mm weight
kg/km
11,5
96,0
14,9
192,0
17,5
384,0
12,9
154,0
19,9
614,0
27,4
960,0
30,4
1344,0

Weight
approx.
kg/km
125,0
340,0
522,0
188,0
815,0
1305,0
1750,0

AWG-No.
8
8
8
6
6
4
2

Dimensions and specifications may be changed without prior notice. (RO01)

O7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

(N)HMH-J halogen-free for fixed installation, emission-free, 300/500V




Technical data

Cable structure

Properties

Plastic-sheathed cable, halogen-free, for


fixed installation
To DINVDE0250 part215
Permissible working temperature
at the conductor +70 C
Nominal voltage
U0/U 300/500 V
Max. voltage for equipment
Um 550 V
Power rating
in accordance with DINVDE0298 part4,
tables3 and 4, analogous for NYM, taking
the type of installation and the appropriate
factors for differing ambient temperatures
and build-up of cables
rated short-circuit current of density acc.
to DINVDE0298 part4 table15
fuse rating according to DINVDE0100
part430
Caloric load values
see Technical Informations

Bare Cu conductor, solid or stranded on


the basis of DINVDE0250 part204 with the
following modifications:
Core insulation of halogen-free
thermoplastic polymer compound with
optimum wall thickness
Colour coded to DINVDE0293-308
Green-yellow earth core, 3 cores and above
for 1 core cable
core colour green-yellow
Cores stranded in layer
Extruded core insulation, halogen-free
Outer jacket of non-cross-linked,
halogen-free thermoplastic polymer
compound
Jacket colour light-grey (RAL7035)


Corrosive nature of combustion gases


(halogen-free verification)
testing acc. to VDE0482part267,
DINEN50267-2-2, IEC60754-2, HD602
(equivalent DINVDE0472 part813)
Behaviour in case of fire
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Low smoke
testing acc. to DINVDE0472 part818


Note

re = round conductor, single-wire;


rm = round conductor, multiple-wire.
G = with green-yellow earth core.
O-version: single core conductor with black
core insulation. Cables with between two
and seven cores are without green-yellow
core.
J-version: with green-yellow core
insulation.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
This plastic-sheathed cable of defined behaviour in case of fire is used for installations in residential dwellings, public buildings as well as in
industrial constructions.
Suitable for applications in dry, damp or wet environments for installation above, on, in and beneath plaster, as well as in masonry and
concrete walls, not however for embedding in vibration, compacted or tamped concrete.
The cable is also approved for outdoor applications provided these are not exposed to direct sunlight radiation. Installation of this cable in
earth or in water is not permitted.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
51996
52001
52009
52016
51997
52002
52010
52017
51992
51998
52003
52011
51993
51999
52004
52012
51994
52000
52005
52013
51995
52006

No.cores x
cross-sec.
mm
3G1,5
re
4G1,5
re
5G1,5
re
7G1,5
re
3G2,5
re
4G2,5
re
5G2,5
re
7G2,5
re
1G4
re
3G4
re
4G4
re
5G4
re
1G6
re
3G6
re
4G6
re
5G6
re
1G10
re
3G10
re
4G10
re
5G10
re
1G16
rm
4G16
rm

Outer
Cop.
approx. mm weight
kg/km
9,4
43,0
10,2
58,0
10,8
72,0
11,4
101,0
10,4
72,0
11,3
96,0
11,9
120,0
13,5
158,0
8,6
38,0
11,8
115,0
13,3
154,0
14,8
192,0
9,9
58,0
13,4
173,0
14,8
230,0
16,0
288,0
11,2
96,0
16,0
288,0
17,4
384,0
18,9
480,0
11,9
154,0
21,6
614,0

Weight
approx.
kg/km
92,0
115,0
133,0
168,0
128,0
152,0
182,0
250,0
62,0
192,0
244,0
300,0
83,0
267,0
345,0
400,0
125,0
628,0
522,0
620,0
188,0
815,0

AWG-No.
16
16
16
16
14
14
14
14
12
12
12
12
10
10
10
10
8
8
8
8
6
6


Part no.
52014
52007
52015
52008

No.cores x
cross-sec.
mm
5G16
rm
4G25
rm
5G25
rm
4G35
rm

Outer
Cop.
approx. mm weight
kg/km
23,8
768,0
27,0
960,0
29,0
1200,0
29,9
1344,0

Weight
approx.
kg/km
995,0
1305,0
1580,0
1750,0

AWG-No.
6
4
4
2

Dimensions and specifications may be changed without prior notice. (RO01)

O8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NHXMH-O/-J halogen-free plastic sheathed cable 300/500 V, VDE approved




Technical data

Cable structure

Properties

Halogen-free plastic-sheathed cable with


enhanced characteristics in case of fire,
according to DINVDE0250 part214
Conductor resistance (at 20 C)
according to DINVDE0295 and IEC60228
Max. temperature at the conductor
during operation +70 C
in case of short circuit +250 C
Temperature range
during installation -5 C to +50 C
fixed installation -30 C to +70 C
Nominal voltage
U0/U 300/500 V
Test voltage 2000 V
Minimum bending radius
single-core approx. 15x cable
multi-core approx. 10x cable
Caloric load values
see Technical Informations

Plain copper conductor, single core up to


10mm
multi-core from 16-35mm
according to DINVDE0295 cl.1 or 2,
BS6360 cl.1 or 2 and IEC60228 cl.1 or 2
Core insulation of cross-linked polymer
compound 2XI1 to DINVDE0207 part22
Colour code according to DINVDE0293-308
for 1 core cable
core colour black or green-yellow
Cores stranded in layer
Overall core jacket of halogen-free filling
compound (not for single-core cables)
Outer jacket, flame-retardant polymer
compound HM2 according to DINVDE0207
part24, halogen-free
Jacket colour grey (RAL7035)

 LS0H = Low Smoke Zero Halogen-free.




Flame-retardant
Halogen-free, no liberation of corrosive or
toxic gases
Limited propagation of fire
Low smoke development, Ozone resistant

Tests
Flame test to VDE0482-332-3, BS4066
part3/ DINEN60332-3/ IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Halogen-free according to VDE0482
part267/ DINEN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to DINVDE0482
part268, HD606, EN50268-12/
IEC61034-12, BS7622 part12 (equivalent
DINVDE0472 part816)
Ozone resistance according to
DINVDE0472 part805
Also deliverable in screened (St) version


Note

re = round conductor, single-wire;


rm = round conductor, multiple-wire.


Application
Halogen-free plastic-sheathed cables with enhanced characteristics in case of fire are used for applications where harm to human life and
damage to property must be prevented in the event of fire, e.g. in industrial installations, communal establishments, hotels, airports,
underground stations, railway stations, hospitals, departmental stores, banks, schools, theatres, multi-storey buildings, process control
centres etc. Suitable for installation in dry, damp or wet environments, for installation above, on, in and beneath plaster as well as in masonry
walls and in concrete, not however for direct embedding in vibration, compacted or tamped concrete. These cables are also suitable for
outdoor applications. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


NHXMH-O
Part no.
53300
53306
53301
53307
53302
53308
53303
53304
53305

No.cores x
cross-sec.
mm
1x1,5
re
2x1,5
re
1x2,5
re
2x2,5
re
1x4
re
2x4
re
1x6
re
1x10
re
1x16
rm

Outer
min. - max.
mm
5,0 - 8,4
7,6 - 9,2
5,4 - 8,8
8,4 - 10,1
6,0 - 9,5
9,6 - 11,6
6,4 - 10,0
7,4 - 11,3
8,5 - 12,4

Cop.
weight
kg/km
15,0
29,0
24,0
48,0
39,0
77,0
58,0
96,0
154,0

Weight
approx.
kg/km
49,0
110,0
60,0
136,0
80,0
202,0
111,0
160,0
232,0

AWG-No.
16
16
14
14
12
12
10
8
6

NHXMH-J
Part no.
53350
53358
53366
53374
53351
53359
53367
53375
53352
53360
53368
53353
53361
53369
53354
53362
53370
53355
53363
53371
53356
53364
53372
53357
53365
53373

No.cores x
cross-sec.
mm
3G1,5
re
4G1,5
re
5G1,5
re
7G1,5
re
3G2,5
re
4G2,5
re
5G2,5
re
7G2,5
re
3G4
re
4G4
re
5G4
re
3G6
re
4G6
re
5G6
re
3G10
re
4G10
re
5G10
re
3G16
rm
4G16
rm
5G16
rm
3G25
rm
4G25
rm
5G25
rm
3G35
rm
4G35
rm
5G35
rm

Outer
min. - max.
mm
8,0 - 9,6
8,5 - 10,3
9,1 - 11,0
9,9 - 11,9
8,7 - 10,6
9,5 - 11,5
10,4 - 12,3
11,4 - 13,8
10,1 - 12,2
11,3 - 13,7
12,5 - 15,1
11,5 - 13,9
12,7 - 15,3
13,7 - 16,6
13,8 - 16,7
15,1 - 18,2
16,3 - 19,7
16,5 - 20,0
18,0 - 21,8
19,7 - 23,8
20,4 - 24,6
22,6 - 27,3
24,7 - 29,8
22,7 - 27,4
24,9 - 30,0
27,5 - 33,2

Cop.
weight
kg/km
43,0
58,0
72,0
101,0
72,0
96,0
120,0
168,0
115,0
154,0
192,0
173,0
230,0
288,0
288,0
384,0
480,0
461,0
615,0
768,0
720,0
960,0
1200,0
1008,0
1344,0
1680,0

Weight
approx.
kg/km
130,0
151,0
177,0
209,0
163,0
200,0
238,0
300,0
235,0
300,0
345,0
323,0
400,0
475,0
485,0
603,0
720,0
850,0
940,0
1142,0
1152,0
1432,0
1800,0
1503,0
1930,0
2490,0

AWG-No.
16
16
16
16
14
14
14
14
12
12
12
10
10
10
8
8
8
6
6
6
4
4
4
2
2
2

Dimensions and specifications may be changed without prior notice. (RO01)

O9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Data, Network & Bus Technology

The complete program, from delivery


advice to installation

Photo: Helukabel

LAN and WAN Networks have steadily increased in importance in


the last few years, and have become the backbone of company
communication.
HELUKABEL can offer an extensive range of equipment for
networking heterogenous systems using Fibre Optic and Copper
techniques Products developed by us for passive applications,
and active components from well-known manufacturers form
the basis of our portfolio.
Our activities can be recognized by the tradenames
HELUCOM, HELUKAT, HELUCOM CONNECTING SYSTEMS and
HELUKAT CONNECTING SYSTEMS.
HELUKABEL offers the complete spectrum of professional
consultation from supply to installation all from one source.

O 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Telephone and
Fire Warning Cables

P1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Telephone and Fire Warning Cables


As a supplier of underground cables such as
telephone cables to be laid in- and outdoors
as well as re warning cables, HELUKABEL can
provide a short term delivery-readiness. Modern
and powerful cutting machines ensure that even
the demands for xed lengths can be processed
within a short time.
Due to our proximity to our customers (stock
in Hemmingen/Stuttgart, Neuenhagen/Berlin,
Pleia/Chemnitz and Windsbach/Nuremberg)
we can also deliver in a short time on the spot
to the customers construction site.
On request we also deliver vehicles with lifting
platform for easier loading and unloading.

P2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description
A-2Y(L)2Y,Bd telephone-outdoor cable, according to VDE 0816, laminated sheath, unfilled...................................................................................
A-2YF(L)2Y,Bd telephone-outdoor cable, according to VDE 0816, laminated sheath, filled cable core, longitudinally water-proof.....................................

J-YY Bd,telephone installation cable, according to VDE 0815.........................................................................................................................


J-Y(St)Y Lg,telephone installation cable, according to VDE 0815....................................................................................................................

J-Y(St)Y Lg,fire warning installation cable.....................................................................................................................................................


S-YY Lg,switchboard cable according to VDE 0813......................................................................................................................................

J-H(St)H,Bd installation cable, halogen-free, according to VDE 0815................................................................................................................

J-H(St)H,Bd fire warning installation cable, halogen-free...................................................................................................................................

J-2Y(St)H,St III Bd 16 Mbits/s (Kat.3) ISDN/EDV (Z = 100 Ohm), halogen-free............................................................................................................

Page
P 4
P 5
P 6
P 7
P 8
P 9

P 10
P 11
P 12

P3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

A-2Y(L)2Y Bd telephone-outdoor cable, according to VDE 0816,


laminated sheath, unfilled


Technical data

Cable structure

Properties

According to DINVDE0816
Temperature range
flexible -20 C to +50 C
fixed installation to +70 C
Loop resistance at 20 C
0,6 mm = max. 130 Ohm/km
0,8 mm = max. 73,2 Ohm/km
Operating voltage (peak voltage)
max. 225 V
Test voltage
core/core U eff. 500)
core/screen U eff. 2000 V
Insulation resistance
min. 5 GOhm x km
Line attenuation
of side circuits at 800 Hz
0,6 mm = 1,04 dB/km
0,8 mm = 0,78 dB/km
Impedance
of side circuites at 800 Hz
0,6 mm = 720 Ohm
0,8 mm = 520 Ohm
Minimum bending radius
approx. 10x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Caloric load values
see Technical Informations

Bare copper conductor, solid, 0,6 and


0,8mm
PE (2Y) core insulation, wall-thickness as
per DINVDE0816 table4
Core identification of quads marked with
black rings
4 cores twisted to a star quad
5 star quads stranded to sub units,
each 5 or 10 sub units stranded to main
units and the sub or main units stranded
to cable core
Core wrapping with several plastic tapes
Outer sheath, as laminated sheath (L)2Y,
PE-coated aluminium tape spliced with
PE(2Y) sheath
PE-outer sheath colour black
Sheath marking continuously with
telephone-receiver, meter marking in white
colour

These are not allowed for the power


installation
For fire and hazardous areas, this cable
type with PE-sheath, the installation is not
permitted without enough protective
precaution
Mutual capacitance at 800 Hz
of all values100%
0,6 mm - max. 52 nF/km
0,8 mm - max. 55 nF/km
of all values 95%
0,6 mm - max. 503) nF/km
0,8 mm - max. 533) nF/km
of all values 80%
0,6 mm - max. 48 nF/km
0,8 mm - max. 50 nF/km
Capacitance unbalances at 800 Hz
of all values k1 100% - max. 800) pF/300 m
of all values k1 98% - max. 400 pF/300 m
of all values k9-12 100% - max. 300) pF/300 m
of all values k9-12 98% - max. 100 pF/300 m


Note

) But at least for 2 quads.


) Local cables with more than 100 pairs the
test conductor/conductor is emitted.
3) For cables up to 10 double cores is the
100 % value valid
Conductor 0,4mm on request.

Application
These external subscriber telephone cables are installed as telecommunication connection cable for connecting the telephone extension
to the telephone exchange or central offices and as well as for industrial plants.
These subscriber connecting cables are suitable for laying in under ground, in cable ducts and cable conduits - and also for indoor-laying.
Both sides of PE-copolymere coated aluminium type (L), which is spliced with the outer PE-sheath ensures a barrier against water vapour
and diagonally water-proof.
Black coloured PE-sheath is UV-resistant.
The Polyethelene material (PE 2Y) is halogen-free.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.pairs x
cross-sec.
mm
34100
2 x 2 x 0,6
34101
4 x 2 x 0,6
34102
6 x 2 x 0,6
34103
10 x 2 x 0,6
34104
20 x 2 x 0,6
34105
30 x 2 x 0,6
34106
40 x 2 x 0,6
34107
50 x 2 x 0,6
34108
70 x 2 x 0,6
34109
100 x 2 x 0,6
34110
150 x 2 x 0,6
34111
200 x 2 x 0,6
34112
250 x 2 x 0,6
34113
300 x 2 x 0,6
34114
350 x 2 x 0,6
34115
400 x 2 x 0,6


Outer
Cop.
approx. mm weight
kg/km
8,0
11,0
10,0
23,0
11,5
34,0
12,5
57,0
15,5
113,0
17,5
170,0
19,5
226,0
21,0
283,0
24,5
396,0
28,0
565,0
33,0
848,0
37,0
1131,0
40,5
1414,0
44,0
1696,0
47,5
1979,0
50,0
2262,0

Weight
approx.
kg/km
82,0
127,0
132,0
171,0
268,0
358,0
438,0
531,0
712,0
950,0
1348,0
1758,0
2137,0
2533,0
2954,0
3342,0


Part no. No.pairs x
cross-sec.
mm
34130
2 x 2 x 0,8
34131
4 x 2 x 0,8
34132
6 x 2 x 0,8
34133
10 x 2 x 0,8
34134
20 x 2 x 0,8
34135
30 x 2 x 0,8
34136
40 x 2 x 0,8
34137
50 x 2 x 0,8
34138
70 x 2 x 0,8
34139
100 x 2 x 0,8
34140
150 x 2 x 0,8
34141
200 x 2 x 0,8
34142
250 x 2 x 0,8
34143
300 x 2 x 0,8
34144
350 x 2 x 0,8
34145
400 x 2 x 0,8
34146
500 x 2 x 0,8
34147
600 x 2 x 0,8

Outer
Cop.
approx. mm weight
kg/km
11,0
20,0
12,0
40,0
13,0
60,0
14,5
101,0
18,0
201,0
21,0
302,0
23,0
402,0
25,5
503,0
29,0
704,0
34,0
1005,0
40,0
1508,0
46,5
2011,0
51,0
2514,0
53,0
3016,0
56,5
3519,0
60,0
4022,0
68,0
5027,0
73,0
6032,0

Weight
approx.
kg/km
102,0
158,0
179,0
241,0
393,0
540,0
675,0
842,0
1105,0
1524,0
2208,0
2915,0
3575,0
4232,0
4940,0
5565,0
6955,0
8240,0

Dimensions and specifications may be changed without prior notice. (RP01)

P4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

A-2YF(L)2Y Bd telephone-outdoor cable, according to VDE 0816, laminated sheath,


filled cable core, longitudinally water-proof


Technical data

Cable structure

Properties

According to DIN VDE 0816


Temperature range
flexible -20 C to +50 C
fixed installation to +70 C
Loop resistance at 20 C
0,6 mm = max. 130 Ohm/km
0,8 mm = max. 73,2 Ohm/km
Operating voltage (peak voltage)
max. 225 V
Test voltage
core/core U eff. 500 V2)
core/screen U eff. 2000 V
Insulation resistance
min. 1,5 GOhm x km
Line attenuation
of side circuits at 800 Hz
0,6 mm = 1,04 dB/km
0,8 mm = 0,78 dB/km
Impedance of side circuites
at 800 Hz
0,6 mm = 720 Ohm
0,8 mm = 520 Ohm
Minimum bending radius
approx. 10x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Caloric load values
see Technical Informations

Bare copper conductor, solid, 0,6 and


0,8mm
PE (2Y) core insulation, wall-thickness as
per DINVDE0816 table4
Core identification of quads marked with
black rings
4 cores twisted to a star quad
5 star quads stranded to sub units,
each 5 or 10 sub units stranded to main
units and the sub or main units stranded
to cable core
Core cavities continuously filled with
petrol-jelly
Core wrapping with paper tape
Outer sheath, as laminated sheath (L)2Y,
PE-coated aluminium tape spliced with PE
(2Y) sheath
PE-outer sheath colour black
Sheath marking continuously with
telephone-receiver, meter marking in white
colour

These cables are not allowed for purposes


of high current and power installation.
These cables with outer PE-jacket are also
not permitted for fire and explosive areas
without any protective measure.
Mutual capacitance at 800 Hz
of all values 100%
0,6 mm - max. 52 nF/km
0,8 mm - max. 55 nF/km
of all values 95%
0,6 mm - max. 503) nF/km
0,8 mm - max. 533) nF/km
of all values 80%
0,6 mm - max. 48 nF/km
0,8 mm - max. 50 nF/km
Capacitance unbalances at 800 Hz
of all values k1 100% - max. 8001) pF/300 m
of all values k1 98% - max. 400 pF/300 m
of all values k9-12 100%-max. 3001) pF/300 m
of all values k9-12 98% - max. 100 pF/300 m


Note

) But at least for 2 quads.


) Local cables with more than 100 pairs the
test conductor/conductor is emitted.
3) For cables up to 10 double cores is the
100 % value valid
Conductor 0,4mm on request.

Application
These external subscriber telephone cables are installed as telecommunication connection cable for connecting the telephone extension
to the telephone exchange for transmitting signals.
These subscriber connecting cables are suitable for laying in under ground, in cable ducts and cable conduits.
According to DIN VDE 0800 part 1, these cables are allowed in all types of installation plants. The cavities of the cable core, filled continuously
with viscous compound (F). Both sides of PE-copolymere coated aluminium type (L), which is spliced with the outer PE-sheath, ensures a
barrier against water vapour and crosswise and longitudinal water tightness. Black coloured PE-sheath is UV-resistant. The Polyethelene
material (PE 2Y) is halogen-free.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.pairs x


cross-sec.
mm
34007
2 x 2 x 0,6
34008
4 x 2 x 0,6
34009
6 x 2 x 0,6
34010
10 x 2 x 0,6
34011
20 x 2 x 0,6
34012
30 x 2 x 0,6
34013
40 x 2 x 0,6
34014
50 x 2 x 0,6
34015
70 x 2 x 0,6
34016
100 x 2 x 0,6
34017
150 x 2 x 0,6
34018
200 x 2 x 0,6
34036
250 x 2 x 0,6
34037
300 x 2 x 0,6
34038
350 x 2 x 0,6
34039
400 x 2 x 0,6
34040
500 x 2 x 0,6

Outer
Cop.
approx. mm weight
kg/km
7,5
11,0
9,0
23,0
12,0
34,0
13,5
57,0
16,0
113,0
19,0
170,0
20,5
226,0
23,0
283,0
26,0
396,0
31,5
565,0
37,5
848,0
42,5
1131,0
47,5
1414,0
51,5
1696,0
55,0
1979,0
60,5
2262,0
66,0
2827,0

Weight
approx.
kg/km
80,0
140,0
150,0
190,0
310,0
430,0
545,0
660,0
895,0
1230,0
1780,0
2320,0
2910,0
3490,0
3970,0
4480,0
5460,0


Part no. No.pairs x
cross-sec.
mm
34029
2 x 2 x 0,8
34030
4 x 2 x 0,8
34019
6 x 2 x 0,8
34020
10 x 2 x 0,8
34021
20 x 2 x 0,8
34022
30 x 2 x 0,8
34023
40 x 2 x 0,8
34024
50 x 2 x 0,8
34025
70 x 2 x 0,8
34026
100 x 2 x 0,8
34027
150 x 2 x 0,8
34028
200 x 2 x 0,8
34031
250 x 2 x 0,8
34032
300 x 2 x 0,8
34033
350 x 2 x 0,8
34034
400 x 2 x 0,8
34035
500 x 2 x 0,8

Outer
Cop.
approx. mm weight
kg/km
8,5
20,0
10,0
40,0
12,5
60,0
15,0
101,0
19,0
201,0
23,0
302,0
26,0
402,0
29,0
503,0
33,0
704,0
39,0
1005,0
47,0
1508,0
51,0
2011,0
58,0
2514,0
62,5
3016,0
68,0
3519,0
73,0
4022,0
81,5
5027,0

Weight
approx.
kg/km
100,0
180,0
190,0
280,0
480,0
670,0
860,0
1060,0
1420,0
1980,0
2940,0
3780,0
4660,0
5570,0
6750,0
7630,0
9540,0

Dimensions and specifications may be changed without prior notice. (RP01)

P5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

J-YY Bd telephone installation cable, according to VDE 0815




Technical data

Cable structure

Properties

Installation cable according to DINVDE0815


Temperature range
during operation -5 C to +50 C
before and after installation
-30 C to +70 C
Loop resistance
at 20 C max. 130 Ohm/km
Nominal voltage
(peak voltage) 300 V
Test voltage (50 Hz)
core/core U eff. 800 V
Insulation resistance
min. 100 MOhm x km
Mutual capacitance
at 800 Hz max. 1001) nF/km
Capacitance unbalances at 800 Hz
k1 max. 3002) pF/100 m
k9...k12 1003) pF/100 m
Line attenuation
at 800 Hz 1,48 dB/km
Minimum bending radius
to DINVDE0891 part5
during delivery 7,5x cable
single bending without tension
2,5x cable
repeated bending under tension
7,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Caloric load values
see Technical Informations

Bare copper conductor, solid, 0,6mm


PVC core insulation, compound type YI1 to
DIN VDE 0207, insulation wall-thickness
0,2mm to table 7
Core and star quad identification to
DINVDE0815
The cores to a quad and each 5 quads to a
unit and several units are stranded in layer
Core wrapping with plastic tape
PVC outer jacket grey, flame retardant,
compound type YM1 to DINVDE0207
part5, jacket wall-thickness to
DINVDE0815 table19

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

This value may be extended by 20% with


a make-up to 4 pairs.
2) 20% of the values, but one value up to
500 pF is allowed.
3) 10% of the values, but four values
(relationship) up to 300 pF are allowed.

1)

Application
J-YY installation cables are preferably used as telephone cables in telephone stations and sub-extensions, suitable for installation in dry and
damp environments in, on and under plaster as well as in the open air for fixed installation on outer walls of buildings.
Telephone-Installation cables are not allowed for purposes of high current and power installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.pairs x
cross-sec.
mm
33100
2 x 2 x 0,6
33101
4 x 2 x 0,6
33102
6 x 2 x 0,6
33103
10 x 2 x 0,6
33104
16 x 2 x 0,6
33105
20 x 2 x 0,6
33106
24 x 2 x 0,6

Outer
Cop.
approx. mm weight
kg/km
4,5
11,0
6,5
23,0
7,0
34,0
8,5
57,0
10,0
90,0
11,0
113,0
11,5
136,0

Weight
approx.
kg/km
34,0
59,0
74,0
111,0
160,0
200,0
224,0


Part no. No.pairs x
cross-sec.
mm
33107
30 x 2 x 0,6
33108
40 x 2 x 0,6
33109
50 x 2 x 0,6
33110
60 x 2 x 0,6
33111
80 x 2 x 0,6
33112
100 x 2 x 0,6

Outer
Cop.
approx. mm weight
kg/km
13,0
170,0
15,0
226,0
16,5
283,0
17,5
339,0
20,3
452,0
22,3
565,0

Weight
approx.
kg/km
284,0
364,0
451,0
529,0
700,0
850,0

Dimensions and specifications may be changed without prior notice. (RP01)

P6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

J-Y(St)Y Lg telephone installation cable, according to VDE 0815




Technical data

Cable structure

Properties

Installation cable according to DINVDE0815


Temperature range
during operation -5 C to +50 C
before and after installation
-30 C to +70 C
Loop resistance at 20 C
0,6 mm - max. 130 Ohm/km
0,8 mm - max. 73,2 Ohm/km
Nominal voltage (peak voltage)
(not for purposes of high current and
power installation)
0,6 mm - 300 V
0,8 mm - 3003) V
Test voltage
core/core U eff. 800 V
core/screen 800 V
Insulation resistance
min. 100 MOhm x km
Mutual capacitance at 800 Hz
max. 1001) nF/km
Capacitance unbalances at 800 Hz
k- max. 3002) pF/100 m
Line attenuation at 800 Hz
0,6 mm - 1,7 dB/km
0,8 mm - 1,1 dB/km
Minimum bending radius
to DIN VDE 0891 part 5
during delivery 7,5x cable
single bending without tension
2,5x cable
repeated bending under tension
7,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Caloric load values
see Technical Informations

As per J-YY, but laid up in pairs and with


electrostatic screen (St)
Bare copper conductor, solid, 0,6 and
0,8mm
PVC core insulation, compound type YI1,
to DINVDE0207, insulation wall-thickness
0,2mm and 0,4mm to table7
Core and pair identification to DINVDE0815
Cores twisted to pairs and the pairs are
stranded in layers
Core wrapping with plastic tape
Electrostatic screen (St) of plastic coated
aluminium foil and drain wire
PVC outer jacket grey, flame retardant,
compound type YM1 to DINVDE0207
part5, jacket wall-thickness to
DINVDE0815 table19

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

This value may be extended by 20% with


a make-up to 4pairs.
2) 20% of the values, but one value up to
500pF is allowed.
3) Short time operation (6 s/min) up to
600V permitted.

1)

Application
This cable type with electrostatic screening (St) protects the transmission circuits against extern electrical interferences. Installation cables
laid up in pairs are preferably used for indoor telecommunication installation in dry and damp places, in, on and under plaster but also in
the open air for fixed installation on outer walls of buildings.
These cables are suitable for telephone stations and sub-extensions, for signal and data transmission. Telephone-Installation cables are not
allowed for purposes of high current and power installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.pairs x


cross-sec.
mm
33001
2 x 2 x 0,6
33002
3 x 2 x 0,6
33003
4 x 2 x 0,6
33004
5 x 2 x 0,6
33005
6 x 2 x 0,6
33006
8 x 2 x 0,6
33007
10 x 2 x 0,6
33008
12 x 2 x 0,6
33009
16 x 2 x 0,6
33010
20 x 2 x 0,6
33011
24 x 2 x 0,6
33012
30 x 2 x 0,6
33013
40 x 2 x 0,6
33014
50 x 2 x 0,6
33015
60 x 2 x 0,6
33016
80 x 2 x 0,6
33017
100 x 2 x 0,6

Outer
Cop.
approx. mm weight
kg/km
5,0
13,0
6,3
18,0
6,5
24,0
7,2
30,0
7,5
35,0
8,0
46,0
10,0
58,0
10,2
71,0
11,0
93,0
12,0
116,0
13,0
139,0
14,0
172,0
15,0
220,0
17,0
286,0
19,0
342,0
21,0
455,0
24,0
568,0

Weight
approx.
kg/km
40,0
50,0
60,0
70,0
80,0
90,0
110,0
130,0
160,0
190,0
220,0
280,0
350,0
430,0
500,0
640,0
850,0


Part no. No.pairs x
cross-sec.
mm
33018
2 x 2 x 0,8
33019
3 x 2 x 0,8
33020
4 x 2 x 0,8
33021
5 x 2 x 0,8
33022
6 x 2 x 0,8
33023
8 x 2 x 0,8
33024
10 x 2 x 0,8
33025
12 x 2 x 0,8
33026
16 x 2 x 0,8
33027
20 x 2 x 0,8
33028
24 x 2 x 0,8
33029
30 x 2 x 0,8
33030
40 x 2 x 0,8
33031
50 x 2 x 0,8
33032
60 x 2 x 0,8
33033
80 x 2 x 0,8
33034
100 x 2 x 0,8

Outer
Cop.
approx. mm weight
kg/km
7,0
21,0
8,5
31,0
9,0
41,0
9,5
52,0
11,0
62,0
11,5
82,0
13,2
102,0
14,2
123,0
16,0
164,0
17,0
204,0
19,0
244,0
20,8
304,0
23,0
405,0
26,0
505,0
28,0
606,0
31,5
807,0
33,0
1008,0

Weight
approx.
kg/km
60,0
80,0
100,0
120,0
140,0
170,0
220,0
250,0
320,0
380,0
460,0
560,0
710,0
900,0
1050,0
1400,0
1750,0

Dimensions and specifications may be changed without prior notice. (RP01)

P7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

J-Y(St)Y Lg fire warning installation cable




Technical data

Cable structure

Properties

Installation cable adapted to DINVDE0815


Temperature range
during operation -5 C to +50 C
before and after installation
-30 C to +70 C
Loop resistance
at 20 C max. 73,2 Ohm/km
Nominal voltage
(peak voltage) 3003) V
(not for purposes of high current and
power installation)
Test voltage (50 Hz)
core/core U eff. 800 V
core/screen 800 V
Insulation resistance
min. 100 MOhm x km
Mutual capacitance
at 800 Hz max. 1001) nF/km
Capacitance unbalances
at 800 Hz k - max. 3002) pF/100 m
Line attenuation
at 800 Hz 1,1 dB/km
Minimum bending radius
to DINVDE0891 part5
during delivery 7,5x cable
single bending without tension
2,5x cable
repeated bending under tension
7,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Solid plain copper wire 0,8mm


PVC core insulation YI1, to DINVDE0207
part4
Cores twisted in pairs Pairs stranded in layer
Plastic coated aluminium foil static
screening (St)
Tinned copper drain wire PVC outer sheath
YM1, to DINVDE0207 part5
Red PVC outer jacket with imprint
"Brandmeldekabel"

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

This value may be extended by 20% with


a make-up to 4pairs.
2) 20% of the values, but one value up to
500pF is allowed.
3) Short time operation (6 s/min) up to
600V permitted.

1)

Application
This cable type with electrostatic screening (St) protects the transmission circuits against extern electrical interferences. Installation cables
laid up in pairs are preferably used for indoor telecommunication installation in dry and damp places, in, on and under plaster but also in
the open air for fixed installation on outer walls of buildings.
These cables are suitable for telephone stations and sub-extensions, for signal and data transmission. Telephone-Installation cables are not
allowed for purposes of high current and power installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.pairs x
cross-sec.
mm
33035
1 x 2 x 0,8
33036
2 x 2 x 0,8
33037
3 x 2 x 0,8
33038
4 x 2 x 0,8
33039
5 x 2 x 0,8
33040
6 x 2 x 0,8
33041
8 x 2 x 0,8
33042
10 x 2 x 0,8
33043
12 x 2 x 0,8
33044
14 x 2 x 0,8

Outer
Cop.
approx. mm weight
kg/km
4,5
11,0
7,0
21,0
8,5
31,0
9,0
41,0
9,5
52,0
11,0
62,0
11,5
82,0
13,2
102,0
14,2
123,0
14,6
145,0

Weight
approx.
kg/km
38,0
60,0
80,0
100,0
120,0
140,0
170,0
220,0
250,0
280,0


Part no. No.pairs x
cross-sec.
mm
33045
16 x 2 x 0,8
33046
20 x 2 x 0,8
33047
24 x 2 x 0,8
33048
30 x 2 x 0,8
33049
40 x 2 x 0,8
33050
50 x 2 x 0,8
33051
60 x 2 x 0,8
33052
80 x 2 x 0,8
33053
100 x 2 x 0,8

Outer
Cop.
approx. mm weight
kg/km
16,0
164,0
17,0
204,0
19,0
244,0
20,8
304,0
23,0
405,0
26,0
505,0
28,0
606,0
31,5
807,0
33,0
1008,0

Weight
approx.
kg/km
320,0
380,0
460,0
560,0
710,0
900,0
1050,0
1400,0
1750,0

Dimensions and specifications may be changed without prior notice. (RP01)

P8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

S-YY Lg switchboard cable according to VDE 0813




Technical data

Cable structure

Properties

Switchboard cable according to


DINVDE0813
Temperature range
during operation
-5 C to +50 C
before and after installation
-30 C to +70 C
Electrical characteristics
according to VDE 0813 at 20 C
Conductor resistance
0,5 mm - max. 96 Ohm/km
0,6 mm - max. 65 Ohm/km
1,0 mm - max. 23,4 Ohm/km
Nominal voltage
0,5 mm - max. 375 V
0,6 mm - max. 375 V
1,0 mm - max. 400 V
Test voltage core/core
0,5 mm - 2000 V
0,6 mm - 2500 V
1,0 mm - 2500 V
Insulation resistance
min. 100 MOhm x km
Min. permissible bending radius
according to DIN VDE 0891 part 3
during operation max. 7,5x cable

Bare copper conductor, solid PVC core


insulation, YI1 to DINVDE0207 part4
Core identification to DINVDE0813
Cores stranded in layers
Core wrapping with plastic tape
PVC outer jacket, YM1 to DINVDE0207
part5
Jacket colour grey (RAL7032)

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Application
In DIN VDE 0800 the operational areas are defined, where the application of switchboard cables permit. These are preferred for the transmission
of data signals of telecommunication and control processings i. e. in interlocking installations, to connect the outdoor cables with relay
groups as well as for fixed installation to interconnect the racks and distributor frames. This type is not allowed for the installation of heavy
current operation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
34300
34301
34302
34303
34304
34305
34306
34307
34308
34309
34310
34311

No. cores
x cond.
mm
30 x 1 x 0,5
60 x 1 x 0,5
10 x 1 x 0,6
20 x 1 x 0,6
30 x 1 x 0,6
60 x 1 x 0,6
80 x 1 x 0,6
20 x 1 x 1
24 x 1 x 1
32 x 1 x 1
40 x 1 x 1
60 x 1 x 1

Outer
approx. mm
9,6
11,9
7,9
9,6
11,1
15,4
18,3
14,5
15,2
16,3
17,8
22,2

Cop.
weight
kg/km
59,0
118,0
28,0
57,0
85,0
170,0
226,0
157,0
188,0
251,0
314,0
471,0

Weight
approx. kg/km
128,0
233,0
98,0
132,0
183,0
344,0
445,0
292,0
328,0
430,0
515,0
710,0

Dimensions and specifications may be changed without prior notice. (RP01)

P9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

J-H(St)H Bd installation cable, halogen-free, according to VDE 0815




Technical data

Cable structure

Properties

Flame retardant, halogen-free installation


cable to DINVDE0815
Temperature range
flexing -5 C to +50 C
fixed installation -30 C to +70 C
Loop resistance at 20 C
max. 130 Ohm/km at 0,6 mm
max. 73,2 Ohm/km at 0,8 mm
Operating top level voltage
300 V (not for purposes of high current
and power installation)
Test voltage
core/core U eff. 800 V
core/screen 800 V
Insulation resistance
min. 100 MOhm x km
Mutual capacitance at 800 Hz
max. 120) nF/km
Capacitance unbalances at 800 Hz
K1 max. 300) pF/100 m
K9-K12 max. 100) pF/100 m
Line attenuation at 800 Hz
approx. 1,5 dB/km
Minimum bending radius
during delivery 7,5x cable
single bending without tension
= 2,5x cable
repeated bending under tension
= 7,5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Caloric load values
see technical informations

Bare copper conductor, solid, 0,6mm


and 0,8mm
Core insulation of halogen-free compound
type HI2, to DINVDE0207 part23
insulation wall thickness 0,3 or 0,4mm
Core and star-quad identification to
DINVDE0815
Cores twisted in quads
The cores to quads and the quads are
stranded to units
Core wrapping with plastic tape
Drain wire solid
Electrostatic screen (St) of plastic coated
aluminium foil
Halogen-free outer jacket type HM2 to
DINVDE0207 part24
Jacket colour grey
LS0H = Low Smoke Zero Halogen-free.

Not for purposes of high current and


power installation as well as underground
laying.
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Tests
Flame test to VDE0482-332-3, BS4066
part3/ DIN EN 60332-3/ IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
(equivalent DINVDE0472 part816)


Note

) This value may be extended by 20% with


make-up up to 4 pairs.
) 20% of the values, but one value up to
500 pF is allowed.
) 10% of the values, but four values
(relationship) up to 300 pF are allowed.

Application
The halogen-free installation cables with improved characteristics in the case of fire are used for the telephone transmission, measurement
and control technology.
The static screen protects the transmission circuits against outer electrical interferences. A fire propagation is prevented through high
oxygen index of the insulation material and produce no corrosive gases in case of fire. Those cables are preferably used for telecommunication
indoor installations and in special cases the outdoor installation is permitted under protection against sunlight. These cables are suitable for
fixed installation in areas with danger of fire, in dry and damp environments as well as on, in and under plaster.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
34050
34051
34052
34053
34054
34055
34056
34057
34058
34059
34060

No.pairs x
cross-sec.
mm
2 x 2 x 0,6
4 x 2 x 0,6
6 x 2 x 0,6
10 x 2 x 0,6
20 x 2 x 0,6
30 x 2 x 0,6
40 x 2 x 0,6
50 x 2 x 0,6
60 x 2 x 0,6
80 x 2 x 0,6
100 x 2 x 0,6

Outer
approx.
mm
5,8
8,6
9,0
10,3
15,5
16,5
18,6
20,7
22,8
26,6
28,2

Cop.
weight
kg/km
14,0
25,0
37,0
59,0
116,0
172,0
229,0
286,0
342,0
455,0
568,0

Weight
approx.
kg/km
50,0
91,0
100,0
147,0
308,0
350,0
465,0
571,0
662,0
877,0
1055,0


Part no.
34061
34062
34063
34064
34065
34066
34067
34068
34069
34070
34071

No.pairs x
cross-sec.
mm
2 x 2 x 0,8
4 x 2 x 0,8
6 x 2 x 0,8
10 x 2 x 0,8
20 x 2 x 0,8
30 x 2 x 0,8
40 x 2 x 0,8
50 x 2 x 0,8
60 x 2 x 0,8
80 x 2 x 0,8
100 x 2 x 0,8

Outer
approx.
mm
6,8
10,5
10,9
13,1
20,4
21,5
24,5
27,1
29,4
33,2
37,2

Cop.
weight
kg/km
25,0
45,0
65,0
106,0
206,0
307,0
407,0
508,0
608,0
809,0
1010,0

Weight
approx.
kg/km
70,0
135,0
151,0
230,0
507,0
600,0
788,0
972,0
1120,0
1475,0
1804,0

Dimensions and specifications may be changed without prior notice. (RP01)

P 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

J-H(St)H Bd fire warning installation cable, halogen-free




Technical data

Cable structure

Properties

Flame retardant, halogen-free installation


cable adapted to DINVDE0815
Temperature range
flexing -5 C to +50 C
fixed installation -30 C to +70 C
Loop resistance at 20 C
max. 73,2 Ohm/km
Operating voltage (peak value)
300 V
(not for purposes of high current and
power installation)
Test voltage
core/core U eff. 800 V
core/screen 800 V
Insulation resistance
min. 100 MOhm x km
Mutual capacitance at 800 Hz
max. 120) nF/km
Capacitance unbalances at 800 Hz
K1 max. 300) pF/100 m
K9-K12 max. 100) pF/100 m
Line attenuation at 800 Hz
approx. 1,5 dB/km
Minimum bending radius
during delivery = 7,5x cable
single bending without tension
= 2,5x cable
repeated bending under tension
= 7,5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Caloric load values
see Technical Informations

Bare copper conductor, solid, 0,8mm


Core insulation of halogen-free compound
type HI2, to DINVDE0207 part23
insulation wall thickness 0,3 or 0,4mm
Core and star-quad identification to
DINVDE0815
Cores twisted in quads
The cores to quads and the quads are
stranded to units
Core wrapping with plastic tape
Drain wire solid
Electrostatic screen (St) of plastic coated
aluminium foil and drain wire
Halogen-free outer jacket type HM2 to
DINVDE0207 part24
Jacket colour red with imprint
"BRANDMELDEKABEL"
LS0H = Low Smoke Zero Halogen-free.

Not for purposes of high current and


power installation as well as underground
laying
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Tests
Flame test to DINVDE0482-332-3, BS4066
part3/ DIN EN60332-3/ IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
Corrosiveness of combustion gases
according to DINVDE0482 part267/
EN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
(equivalent DINVDE0472 part816)


Note

) This value may be extended by 20% with


make-up up to 4 pairs.
) 20% of the values, but one value up to
500 pF is allowed.
) 10% of the values, but four values
(relationship) up to 300 pF are allowed.

Application
The halogen-free installation cables with improved characteristics in the case of fire are used for the telephone transmission, measurement
and control technology.
The static screen protects the transmission circuits against outer electrical interferences. A fire propagation is prevented through high
oxygen index of the insulation material and produce no corrosive gases in case of fire. Those cables are preferably used for telecommunication
indoor installations and in special cases the outdoor installation is permitted under protection against sunlight.
These cables are suitable for fixed installation in areas with danger of fire, in dry and damp environments as well as on, in and under plaster.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
34116
34117
34118
34119
34120
34121

No.pairs x
cross-sec.
mm
2 x 2 x 0,8
4 x 2 x 0,8
6 x 2 x 0,8
10 x 2 x 0,8
20 x 2 x 0,8
30 x 2 x 0,8

Outer
approx.
mm
6,8
10,5
10,9
13,1
20,4
21,5

Cop.
weight
kg/km
25,0
45,0
65,0
106,0
206,0
307,0

Weight
approx.
kg/km
70,0
135,0
151,0
230,0
507,0
600,0


Part no.
34122
34123
34124
34125
34126

No.pairs x
cross-sec.
mm
40 x 2 x 0,8
50 x 2 x 0,8
60 x 2 x 0,8
80 x 2 x 0,8
100 x 2 x 0,8

Outer
approx.
mm
24,5
27,1
29,4
33,2
37,2

Cop.
weight
kg/km
407,0
508,0
608,0
809,0
1010,0

Weight
approx.
kg/km
788,0
972,0
1120,0
1475,0
1804,0

Dimensions and specifications may be changed without prior notice. (RP01)

P 11
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

J-2Y(St)H St III Bd 16 Mbits/s (Kat.3) ISDN/EDV (Z = 100 Ohm), halogen-free




Technical data

Cable structure

Properties

Special core insulation of PE


Adapted to DINVDE0815 and 0816
Conductor loop-resistance
max. 130 Ohm/km
Temperature range
flexing -5 C to +70 C
fixed installation -30 C to +70 C
Operating peak voltage 300 V
(not for purposes of high current and
power installation)
Test voltage 800 V
Insulation resistance
min. 5 GOhm x km
Mutual capacitance 48 nF/km
Characteristic impedance (Z)
at 4-16 MHz: 100 Ohm 15%
Capacitance unbalance
K1 max. 400 pF/300 m
K9-K12 max. 100 pF/300 m
Rel. velocity ratio approx. 0,66
Attenuation at
1 MHz: 28 dB/km
4 MHz: 47 dB/km
5 MHz: 51 dB/km
10 MHz: 65 dB/km
15 MHz: 76 dB/km
16 MHz: 78 dB/km
20 MHz: 89 dB/km
Cross-talk attenuation
from 4 MHz up to 16 MHz
for 2 pairs: min. 40 dB
4 pairs and above: min. 25 dB
Minimum bending radius
stationary approx. 10x cable

Bare, solid copper conductor 0,6mm


Core insulation of PE (2Y)
Colour coding to DINVDE0815
Conductors twisted to quads
5 quads twisted to units
Static screen of plastics coated alu foil with
drain wire 0,6mm
Outer jacket flame retardant, halogen-free
polymer-compound
Jacket colour grey

Outer jacket
Flame test to VDE0482-332-3, BS4066
part3/ DINEN60332-3/ IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
These cables are not allowed for purposes
of high current and power installation
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Application
Used as data transmission and connection cable suitable for fixed installation in and under plaster, for data transmission applications, for
periphery instrument data processing computers.
Suitable for transmission of analog- and digital signals up to 16 Mbit/s. High cross-talk attenuation values.
Suitable as connecting cable for periphery equipment, data processing systems, monitors, Printers and cash register systems.
The static screen (St) screen assures a disturbance-free data and signal transmission for measuring and control systems.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
34166
34167
34168
34169
34170
34171

No.pairs x
cross-sec.
mm
2 x 2 x 0,6
4 x 2 x 0,6
6 x 2 x 0,6
8 x 2 x 0,6
10 x 2 x 0,6
20 x 2 x 0,6

Outer
approx.
mm
5,8
9,2
9,3
9,5
9,8
12,7

Cop.
weight
kg/km
13,0
24,0
35,0
46,0
58,0
116,0

Weight
approx.
kg/km
44,0
80,0
86,0
105,0
112,0
218,0


Part no.
34172
34173
34174
34175
34176
34177

No.pairs x
cross-sec.
mm
30 x 2 x 0,6
40 x 2 x 0,6
50 x 2 x 0,6
60 x 2 x 0,6
80 x 2 x 0,6
100 x 2 x 0,6

Outer
approx.
mm
15,0
16,8
18,5
20,2
23,0
25,2

Cop.
weight
kg/km
172,0
229,0
266,0
342,0
455,0
588,0

Weight
approx.
kg/km
302,0
376,0
480,0
560,0
748,0
940,0

Dimensions and specifications may be changed without prior notice. (RP01)

P 12
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Power Cables, Security Cables


and Medium Voltage Cables

Q1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Power Cables, Security Cables


and Medium Voltage Cables
Medium Voltage Power Cables up to 30 kV
with XLPE-insulation
The XLPE-insulation possesses very good electrical,
mechanical and thermal characteristics in medium
voltage networks. This type of insulation is
outstandingly chemically resistant and also
resistant to cold. Due to various advantages,
the XLPE-insulated type has vastly displaced the
traditional classical paper insulated types in many
sectors.
The XLPE-insulated medium voltage cables are
designed to be longitudinally water-proof. In
comparison to PVC and paper-insulated cables,
the advantage of XLPE-insulated medium voltage
power cables is that they possess a low dielectric
factor.
The good properties of XLPE-insulated cables
remain constant through a wide temperature
range. These cables can be laid in earth, in air or in
tubes.
Further information for laying, bending radius
ambient temperatures, permissible tensile
strength with pulling head test voltages can be
found in the following pages.

Due to our proximity to our customers (stock


in Hemmingen/Stuttgart, Neuenhagen/Berlin,
Pleia/Chemnitz and Windsbach/Nuremberg)
we can also deliver in a short time on the spot
to the customers construction site.

Q2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description

Page

Power Cables
NYY-J / NYY-O,power cable, 0,6/1kV, VDE approved............................................................................................................................
N2XY,power cable, 0,6/1 kV, VDE approved, higher current carrying capacity..................................................................................................
NAYY,power cable, 0,6/1 kV, VDE approved..........................................................................................................................................
NA2XY,power cable, 0,6/1 kV, VDE approved, higher current carrying capacity...............................................................................................
NYCY,power cable, 0,6/1kV, VDE approved, with concentric copper conductor..............................................................................................
N2XCY,power cable, 0,6/1 kV, VDE approved, higher current carrying capacity...............................................................................................
NYCWY,power cable, 0,6/1kV, with concentric copper conductor, VDE approved...........................................................................................
NAYCWY,power cable, 0,6/1kV, with concentric copper conductor, VDE approved.........................................................................................
A-LiY(StE)Y,Data transmission cables for petrol stations and refineries with BAM*-test report...................................................................................
Petrol Station Cables,(N)YY-J 0,6/1 kV, with BAM-test report.......................................................................................................................
NYKY-J 0,6/1kV,with lead sheath, VDE approved...................................................................................................................................

Q 11
Q 12
Q 14
Q 16
Q 18
Q 19
Q 20
Q 21

Security Cables
N2XH,power cable, 0,6/1 kV, halogen-free, without functionality...............................................................................................................
N2XCH,power cable, 0,6/1kV, halogen-free, with concentric conductor, without functionality...........................................................................
JE-H(St)H,Bd FE 180/E 30 bis E 90 (orange), halogen-free.................................................................................................................................
JE-H(St)H,Bd fire warning cable, FE 180/E 30 to E 90 (red), halogen-free...............................................................................................................
JE-H(St)HRH,Bd fire warning cable, FE 180/E 30 to E 90, halogen-free............................................................................................................
N2XH-FE 180/E 30,security cable, halogen-free, 0,6/1kV, with improved fire characteristics..............................................................................
N2XCH-FE 180/E 30,security cable, halogen-free, 0,6/1kV, with improved fire characteristics............................................................................
NHXH-FE 180/E 30,security cable, halogen-free, 0,6/1kV, with improved fire characteristics.............................................................................
NHXCH-FE 180/E 30,security cable, halogen-free, 0,6/1kV, with improved fire characteristics...........................................................................
N2XH-FE 180/E 90,security cable, halogen-free, 0,6/1kV, with improved fire characteristics...................................................................................
N2XCH-FE 180/E 90,security cable, halogen-free, 0,6/1kV, with improved fire characteristics................................................................................
NHXH-FE 180/E 90,security cable, halogen-free, 0,6/1kV, with improved fire characteristics.............................................................................
NHXCH-FE 180/E 90,security cable, halogen-free, 0,6/1kV, with improved fire characteristics...........................................................................

Q 24
Q 26
Q 28
Q 29
Q 30
Q 31
Q 33
Q 35
Q 37
Q 39
Q 41
Q 43
Q 45

Medium Voltage Power Cables


N2XSY 6/10kV, 12/20kV, 18/30kV,XLPE-insulated, Cu-conductor, single core, screened, PVC-jacket...............................................................
NA2XSY 6/10kV, 12/20kV, 18/30kV,XLPE-insulated, alu-conductor, single core, screened, PVC-jacket.............................................................
N2XS2Y 6/10kV, 12/20kV, 18/30kV,XLPE-insulated, Cu-conductor, single core, screened, PE-jacket...............................................................
NA2XS2Y 6/10kV, 12/20kV, 18/30kV, XLPE-insulated, Cu-conductor, single core, screened, PE-jacket............................................................
N2XS(F)2Y 6/10kV, 12/20kV, 18/30kV,XLPE-insulated, Cu-conductor, single core, longitudinally water-tight, screened, PE-jacket..........................
NA2XS(F)2Y 6/10kV, 12/20kV, 18/30kV,XLPE-insulated, alu-conductor, single core, longitudinally water-tight, screened, PE-jacket........................
N2XSEY 3 x ... 6/10kV,XLPE-insulated, Cu-conductor, PVC-jacket...............................................................................................................

Q 50
Q 52
Q 54
Q 56
Q 58
Q 60
Q 62

Q 6
Q 8
Q 9

Q3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Code-designation for power cables


with PVC or XLPE insulation
Design

Identication
of design

Explanations

Core

According to VDE standard


(no abbreviation for copper conductor)

Aluminium conductors

Insulation of thermoplastic
Polyvinylchloride (PVC)

2X

Insulation cross-linked Polyethylene (XLPE)

Concentric conductors of copper wires and copper


tape, helically wounded

CW

Concentric conductor of copper wires in waveconal


formation and copper tape, helically wounded

CE

Concentric conductor of copper wires and copper


tape over each individual core, helically wounded

Screen of copper wires and copper tape, helically


wounded

SE

Screen of copper wires and copper tape over each


individual core, helically wounded

(F)

Longitudinally water-proof screen

Armour of steel tape

Armour of galvanized at steel wires

Counter helix of galvanized steel tape

Sheath

Lead sheath

Outer jacket

PVC jacket

2Y

PE jacket

Concentric conductor,
screen

Screen

Armour

Cable for U0/U 0,6/1 kV are additionally designated with


J

Cables with green-yellow (green-natural) core are


marked with protective conductor

able without green-yellow (green-natural) core are


marked without protective conductor

Q4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NYY-J and NYY-O


N2XY
NAYY-J
NA2XY
NYCY
N2XCY
NYCWY
NAYCWY
A-LiY(StE)Y
Petrol Station Cable
NYKY-J 0,6/1kV
Photo: HELUKABEL

Power Cables

Q5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NYY-J / NYY-O power cable, 0,6/1kV, VDE approved




Technical data

Cable structure

Properties

Power and control cable to DINVDE0276


part603 S1, HD603.1 and IEC60502,
7 core and above to DINVDE0276 part627,
HD627S1 and IEC60502
Temperature range
flexing -5 C to +50 C
fixed installation -40 C to +70 C
Permissible operating temperature
at conductor +70 C
Permissible short circuit temperature
+160 C (short circuit duration 5 sec.)
Nominal voltage U0/U 0,6/1 kV
Test voltage 4 kV
Max. permissible tensile stress with
cable grip for Cu-conductor
= 50 N/mm
Minimum bending radius
for single core approx. 15x cable
for multi core approx. 12x cable
Power ratings table
see Technical Informations
Caloric load values
see Technical Informations

Plain copper conductor, to DINVDE0295


cl.1 or cl.2 solid or stranded type, BS6360
cl.1 or cl.2, IEC60228 and HD383
PVC core insulation, DIV4 to HD603.1
Cores stranded concentrically
Colour coded to DINVDE0293-308, 0276
part603 or HD186
Core colour for 3+ conductor
J-type: gnye (), bn, bk, gy
O-type: bu (), bn, bk, gy
PVC outer jacket, DMV5 to HD603.1
Sheath colour black

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Highest permissible voltage
Direct current systems1,8 kV
Alternating current systems,
single-phase systems1,4 kV
Both conductors insulated,
single-phase systems0,7 kV
One conductor earthed,
three-phase systems1,2 kV
With concentric conductor and
a cross-section of 240 mm
and above3,6 kV


Note

re = round conductor, single-wire;


rm = round conductor, multiple-wire;
sm = stranded, sectional core.
Also available in NYFGBY, NYBY versions etc.
2 cores = adapted to DINVDE.
In respect to 3+ conductors
Whereby only one conductor is allowed to
contain a smaller cross-section (as per
DINVDE0276 part603 table5) and
permitted to place as insulated core
(gree-yellow and blue as -conductor),
stranded in layer.

Application
Power cables for energy supply are installed in open air, in underground, in water, indoors, in cable ducts, power stations, for industry and
distribution boards as well as in subscriber networks, where mechanical damages are not to be expected.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



No.cores x
cross-sec.
mm
1x4
1x6
1 x 10
1 x 16
1 x 25
1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
1 x 150
1 x 185
1 x 240
1 x 300
1 x 400
1 x 500
1 x 630

re
re
re
re
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm

Outer
Cop.
approx. mm weight
kg/km
9,0
38,0
9,5
58,0
10,0
96,0
11,0
154,0
12,0
240,0
13,0
336,0
15,0
480,0
16,5
672,0
19,0
912,0
20,5
1152,0
22,5
1440,0
25,0
1776,0
28,0
2304,0
30,0
2880,0
34,0
3840,0
38,0
4800,0
43,0
6048,0

Weight
approx.
kg/km
115,0
135,0
179,0
245,0
360,0
470,0
620,0
810,0
1110,0
1360,0
1670,0
2050,0
2630,0
3200,0
4150,0
5200,0
6650,0

J type
Part no.
32001
32002
32003
32004
32005
32006
32007
32008
32009
32010
32011
32012
32013
32014
32015
32556
32557

AWG-No.
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
-

O type
Part no.
32089
32090
32091
32092
32093
32094
32095
32096
32097
32098
32099
32100
32101
32102
32103
32558
32559

AWG-No.
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
-

Continuation

Q6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NYY-J / NYY-O power cable, 0,6/1kV, VDE approved



No.cores x
cross-sec.
mm
2 x 1,5
2 x 2,5
2x4
2x6
2 x 10
2 x 16
2 x 25
3 x 1,5
3 x 2,5
3x4
3x6
3 x 10
3 x 16
3 x 25
3 x 35
3 x 50
3 x 70
3 x 95
3 x 120
3 x 150
3 x 185
3 x 240
4 x 1,5
4 x 2,5
4x4
4x6
4 x 10
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
4 x 95
4 x 120
4 x 150
4 x 185
4 x 240
5 x 1,5
5 x 2,5
5x4
5x6
5 x 10
5 x 16
5 x 25
5 x 35
5 x 50
7 x 1,5
7 x 2,5
7x4
7x6
7 x 10
10 x 1,5
10 x 2,5
12 x 1,5
12 x 2,5
14 x 1,5
14 x 2,5
16 x 1,5
16 x 2,5
19 x 1,5
19 x 2,5
21 x 1,5
21 x 2,5
24 x 1,5
24 x 2,5
30 x 1,5
30 x 2,5
40 x 1,5
40 x 2,5
52 x 2,5
61 x 1,5

re
re
re
re
re
re
rm
re
re
re
re
re
re
rm
sm
sm
sm
sm
sm
sm
sm
sm
re
re
re
re
re
re
rm
sm
sm
sm
sm
sm
sm
sm
sm
re
re
re
re
re
re
rm
rm
rm
re
re
re
re
re
re
re
re
re
re
re
re
re
re
re
re
re
re
re
re
re
re
re
re
re

Outer
Cop.
approx. mm weight
kg/km
11,0
29,0
12,0
48,0
14,0
77,0
15,0
115,0
16,5
192,0
18,5
307,0
23,5
480,0
11,5
43,0
12,5
72,0
14,0
115,0
15,0
173,0
17,0
288,0
19,0
461,0
24,0
720,0
25,0
1008,0
26,5
1440,0
30,0
2016,0
34,5
2736,0
37,0
3456,0
40,0
4320,0
46,0
5328,0
51,0
6912,0
12,0
58,0
13,5
96,0
15,0
154,0
16,5
230,0
18,5
384,0
21,5
614,0
26,0
960,0
27,5
1344,0
30,0
1920,0
34,0
2688,0
39,0
3648,0
42,5
4608,0
47,5
5760,0
52,0
7104,0
58,0
9216,0
13,0
72,0
14,5
120,0
16,5
192,0
18,0
288,0
20,0
480,0
22,5
768,0
28,0
1200,0
34,0
1680,0
40,0
2400,0
15,5
101,0
16,5
168,0
18,5
269,0
20,0
403,0
23,5
672,0
18,0
144,0
19,5
240,0
19,0
173,0
20,5
288,0
20,0
202,0
21,0
336,0
21,0
230,0
22,0
384,0
22,0
274,0
23,0
456,0
23,0
302,0
24,5
504,0
25,0
346,0
27,0
576,0
26,0
432,0
28,0
720,0
29,0
576,0
31,5
960,0
35,0
1248,0
34,0
878,0

Weight
approx.
kg/km
175,0
215,0
295,0
370,0
495,0
670,0
960,0
195,0
250,0
340,0
430,0
590,0
820,0
1320,0
1450,0
1850,0
2450,0
3300,0
4100,0
4900,0
6500,0
8300,0
230,0
300,0
410,0
520,0
730,0
1045,0
1640,0
1760,0
2350,0
3100,0
4250,0
5300,0
6400,0
8500,0
11000,0
270,0
360,0
490,0
600,0
890,0
1255,0
1960,0
2400,0
3500,0
310,0
450,0
640,0
850,0
1200,0
380,0
520,0
420,0
600,0
470,0
680,0
520,0
750,0
570,0
850,0
650,0
980,0
750,0
1100,0
860,0
1280,0
1070,0
1700,0
2150,0
1680,0

J type
Part no.
32016
32017
32018
32019
32020
32021
32022
32023
32024
32025
32026
32027
32028
32029
32030
32031
32032
32033
32034
32293
32294
32295
32044
32045
32046
32047
32048
32049
32050
32051
32052
32053
32054
32055
32056
32057
32058
32059
32060
32061
32062
32063
32064
32065
32300
32257
32066
32076
32086
32087
32088
32067
32077
32068
32078
32069
32079
32070
32080
32071
32081
32072
32082
32073
32083
32074
32084
32075
32085
32169
32176

AWG-No.
16
14
12
10
8
6
4
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
16
14
12
10
8
6
4
2
1
16
14
12
10
8
16
14
16
14
16
14
16
14
16
14
16
14
16
14
16
14
16
14
14
16

O type
Part no.
32104
32105
32106
32107
32108
32109
32110
32111
32112
32113
32114
32115
32116
32117
32118
32119
32120
32121
32122
32296
32297
32298
32132
32133
32134
32135
32136
32137
32138
32139
32140
32141
32142
32143
32144
32145
32146
32147
32148
32149
32150
32151
32152



32153
32163

32174
32175
32154
32164
32155

32156

32157

32158
32168
32159

32160

32161

32162




AWG-No.
16
14
12
10
8
6
4
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
16
14
12
10
8
6

16
10
10
8
16
10
16
16
16
16
10
16
16
16
16

3+1/2-conductors
No.cores x
cross-sec.
mm
3 x 25 / 16
3 x 35 / 16
3 x 50 / 25
3 x 70 / 35
3 x 95 / 50
3 x 120 / 70
3 x 150 / 70
3 x 185 / 95
3 x 240 / 120
3 x 300 / 150

Outer
Cop.
approx. mm weight
kg/km
rm/re
24,5
874,0
sm/re
26,0
1162,0
sm
29,0
1680,0
sm/rm
32,0
2352,0
sm
38,0
3216,0
sm
41,0
4128,0
sm
46,0
4992,0
sm
51,0
6240,0
sm
58,0
8064,0
sm
64,0
10080,0

Weight
approx.
kg/km
1530,0
1750,0
2350,0
2850,0
3850,0
4780,0
5800,0
7600,0
9800,0
11500,0

J type
Part no.
32035
32036
32037
32038
32039
32040
32041
32042
32043
32256

AWG-No.
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil

O type
Part no.
32123
32124
32125
32126
32127
32128
32129
32130
32131


AWG-No.
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil

Dimensions and specifications may be changed without prior notice. (RQ01)

Q7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XY power cable, 0,6/1 kV, VDE approved, higher current carrying capacity


Technical data

Cable structure

Properties

Power and control cable accordingto


DINVDE0276 part603 S1or HD603 and
IEC60502
Temperature range
Flexing -5 C to +50 C
Fixed installation -40 C to +70 C
Permissible operating temperature
at theconductor +90 C
Permissible short circuit temperature
+250 C (short circuit duration 5 sec.)
Nominal voltage
U0/U 0,6/1 kV
Test voltage 4 kV
Max. permissible tensile load
with cable grip = 50 N/mm
Minimum bending radius
Single-core approx. 15x cable
Multi-core approx. 12x cable

Bare copper conductor according to DIN


VDE 0295 cl. 1 or cl. 2, single-wire or
multi-wire, BS 6360 cl. 1 or cl. 2, IEC 60228
cl. 1 or cl. 2 or HD 383
Core insulation from cross-linked
polyethylene compound, DIX3 according
to HD 603.1
Cores stranded in concentric layers
Core colours in accordance with DIN VDE
0293-308, 0276 Part 603 or HD 186 PVC
outer sheath, DMV6/DMP2 according to
HD 603.1
Sheath colour - black

Self-extinguishing and flame retardant


inaccordancewith VDE 0482-332-1-2, DIN
EN 60332-1-2/ IEC60332-1 (conforms
toDINVDE0472 part804 Test methodB)
The materials used in manufacture are free
of silicone, cadmium and substances that
impair paint wetting 
Highest permissible voltage
Direct current systems 1,8 kV
Three-phase systems
Single-phase systems:
Both outerconductors insulated 1,4 kV
Single-phase systems:
One conductor earthed 0,7 kV
Three-phase systems 1,2 kV


Note

re = round conductor, single-wire;


rm= round conductor, multi-wire
sm = sector-shaped conductor, multi-wire

Application
Power distribution cables forusein underground, in water, outdoors, in concrete, indoors, in cable ducts, for power stations,industrial
applicationsandswitching systems,as well as inlocal networksif nomechanical damage is expected. Respecting the permissible operating
temperature at the conductor of +90 C permits a higher current carrying capacity than PVC insulated power distribution cables.
= The productconformsto the EC Low-Voltage Directive 2006/95/EG.



No.cores x
cross-sec.
mm
1 x 16
1 x 25
1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
1 x 150
1 x 185
1 x 240
1 x 300
1 x 400
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
4 x 95
4 x 120
4 x 150
4 x 185
4 x 240

re
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm

Outer
Cop.
approx. mm weight
kg/km
11,5
154,0
12,5
240,0
13,5
336,0
15,5
480,0
17,0
672,0
19,0
912,0
20,5
1152,0
23,0
1440,0
25,5
1776,0
28,5
2304,0
30,0
2880,0
34,0
3840,0
21,5
614,0
26,0
960,0
27,5
1344,0
30,0
1920,0
34,0
2688,0
39,0
3648,0
42,5
4608,0
47,5
5760,0
52,0
7104,0
58,0
9216,0

Weight
approx.
kg/km
242,0
362,0
470,0
620,0
805,0
1108,0
1360,0
1670,0
2050,0
2635,0
3200,0
4150,0
1042,0
1640,0
1760,0
2350,0
3100,0
4250,0
5300,0
6400,0
8500,0
11000,0

J type
Part no.
32850
32851
32852
32853
32854
32855
32856
32857
32858
32859
32860
32861
32874
32875
32876
32877
32878
32879
32880
32881
32882
32883

AWG-No.
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil

O type
Part no.
32862
32863
32864
32865
32866
32867
32868
32869
32870
32871
32872
32873
32884
32885
32886
32887
32888
32889
32890
32891
32892
32893

AWG-No.
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil

Dimensions and specifications may be changed without prior notice. (RQ01)

Q8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NAYY power cable, 0,6/1 kV, VDE approved




Technical data

Cable structure

Properties

Power and control cable to DINVDE0276


part603, HD603S1 and IEC60502
Insulation and jacket-compound of
thermoplastic PVC
Temperature range
flexing -5 C to +50 C
fixed installation -40 C to +70 C
Permissible operating temperature
at conductor +70 C
Permissible short circuit temperature
+160 C (short circuit duration 5 sec.)
Nominal voltage U0/U 0,6/1 kV
Test voltage 4 kV
Max. permissible tensile stress
with cable grip for Alu-conductor
= 30 N/mm
Current carrying capacity
as per DINVDE0276 part603,
in normal operation table 14 and 15,
under short circuit conditions table 17
Minimum bending radius
for multi core approx. 12x cable
for single core approx. 15x cable
Current carrying capacity
see Technical Informations
Caloric load values
see Technical Informations

Solid aluminium conductor, as per


VDE0295 cl.1 or cl.2 (round and sector
shaped), BS6360 cl.1 or cl.2, IEC60228
and HD383
PVC core insulation, DIV4 to HD603.1
Conductor colours: green-yellow, brown,
black, grey
Cores stranded in layers
Inner covering
PVC outer jacket black, DMV5 to HD603.1
Sheath colour black

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Highest permissible voltage
Direct current systems 1,8 kV
Alternating current systems,
single-phase systems
Both conductors insulated 1,4 kV
single-phase systems
One conductor earthed 0,7 kV
three-phase systems 1,2 kV


Note

re = round solid core;


se = sectional core;
rm = stranded core.

Application
Power cables for energy supply are installed in open air, in underground, in water, indoors, in cable ducts, power stations, for industry and
distribution boards as well as in subscriber networks, where mechanical damages are not be expected.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



No.cores x
cross-sec.
mm
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
4 x 95
4 x 95
4 x 120
4 x 120
4 x 150
4 x 150
4 x 185
4 x 185
4 x 240
4 x 240
4 x 300
4 x 300

Outer
Alu weight
approx. mm kg/km
re
re
re
se
se
se
sm
se
sm
se
sm
se
sm
se
sm
se
sm

23,0
26,0
28,5
30,0
35,0
39,5
39,5
44,0
44,0
46,0
46,0
51,0
51,0
56,0
56,0
64,0
64,0

186,0
290,0
406,0
580,0
812,0
1102,0
1102,0
1392,0
1392,0
1740,0
1740,0
2146,0
2146,0
2784,0
2784,0
3480,0
3480,0

Weight
approx.
kg/km
750,0
950,0
1120,0
1151,0
1549,0
2030,0
2030,0
2400,0
2400,0
3030,0
3030,0
3650,0
3650,0
4800,0
4800,0
5596,0
5596,0

J type
Part no.
32301
32302
32303
32304
32305
32306
32177
32307
32178
32308
32179
32309
32180
32310
32181
32182
32183

AWG-No.
6
4
2
1
2/0
3/0
3/0
4/0
4/0
300 kcmil
300 kcmil
350 kcmil
350 kcmil
500 kcmil
500 kcmil
600 kcmil
600 kcmil

O type
Part no.
32184
32185
32186
32187
32188
32189
32190
32191
32192
32193
32194
32195
32196
32197
32198
32199
32258

AWG-No.
6
4
2
1
2/0
3/0
3/0
4/0
4/0
300 kcmil
300 kcmil
350 kcmil
350 kcmil
500 kcmil
500 kcmil
600 kcmil
600 kcmil

Continuation

Q9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NAYY power cable, 0,6/1 kV, VDE approved



No.cores x
cross-sec.
mm
5 x 10
5 x 16
5 x 25
5 x 35
5 x 50
5 x 70
5 x 95
5 x 120

Outer
Alu weight
approx. mm kg/km
re
re
re
re
sm
sm
sm
sm

22,0
25,0
28,0
31,0
35,0
40,0
45,0
49,0

145,0
232,0
363,0
508,0
725,0
1015,0
1378,0
1740,0

Weight
approx.
kg/km
637,0
832,0
1175,0
1399,0
1855,0
2351,0
3071,0
3631,0

J type
Part no.
33275
33276
33277
33278
33279
33280
33281
33282

AWG-No.
8
6
4
2
1
2/0
3/0
4/0

O type
Part no.
33283
33284
33285
33286
33287
33288
33289
33290

AWG-No.
8
6
4
2
1
2/0
3/0
4/0


No.cores x
cross-sec.
mm
1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
1 x 150
1 x 185
1 x 240
1 x 300
1 x 400
1 x 500
1 x 630

Outer
Alu weight
approx. mm kg/km
re
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm

13,0
15,0
16,5
19,0
20,5
22,5
25,0
28,0
30,0
34,0
38,0
43,0

102,0
145,0
203,0
276,0
348,0
435,0
537,0
696,0
870,0
1160,0
1450,0
1827,0

Weight
approx.
kg/km
240,0
360,0
410,0
570,0
691,0
804,0
979,0
1253,0
1395,0
1890,0
2600,0
2780,0

J type
Part no.
32328
32329
32390
32391
32392
32393
32394
32395
32396
32397
32398
32399

AWG-No.
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
-

O type
Part no.
32311
32312
32313
32314
32315
32321
32322
32323
32324
32325
32326
32327

AWG-No.
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
-

Dimensions and specifications may be changed without prior notice. (RQ01)

Q 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NA2XY power cable, 0,6/1 kV, VDE approved, higher current carrying capacity


Technical data

Cable structure

Properties

Power and control cable accordingto


DINVDE0276 Part603 S1orHD603.1 and
IEC60502
Temperature range
Flexing -5 C to +50 C
Fixed installation -40 C to +70 C
Permissible operating temperature
at theconductor +90 C
Permissible short circuit temperature
+250 C (short circuit duration 5 sec.)
Nominal voltage
U0/U 0,6/1 kV
Test voltage 4 kV
Max. permissible tensile load
with cable grip for Alu-conductor
= 30 N/mm
Minimum bending radius
Single-core approx. 15x cable
Multi-core approx. 12x cable

Aluminium conductor, according to DIN


VDE0295 cl.1 or cl.2 single-wire or
multi-wire, BS6360 cl.1 or cl.2, IEC60228
cl. 1 or cl.2 orHD383
Core insulationfrom cross-linked
polyethylen compound, DIX3in accordance
withHD603.1
Cores stranded in concentriclayers
Core colours according to DIN VDE
0293-308, 0276 part 603 or HD 186
PVC outer sheath, DMV6/DMP2
accordingto HD 603.1
 Sheath colour -black
PVC outer sheat, DMV6/DMP2 to HD603.1
Sheath colour black

Self-extinguishing and flame retardant


inaccordance with VDE 0482-332-1-2, DIN
EN 60332-1-2/ IEC60332-1 (conforms to
DINVDE0472 part804 Test methodB)
The materials used in manufacture arefree
of silicone, cadmium and substances that
impair paint wetting
Highest permissible voltage
Direct current systems 1,8 kV
Three-phase systems
Single-phase systems:
Both outerconductors insulated 1,4 kV
Single-phase systems:
One outerconductor earthed 0,7 kV
Three-phase systems 1,2 kV


Note

re = round conductor, single-wire;


se = round conductor, multi-wire
sm =sector-shaped conductor, multi-wire

Application
Power distribution cables forusein underground, in water, outdoors, in concrete, indoors, in cable ducts, for power stations,industrial
applicationsandswitching systems,as well as inlocal networksif nomechanical damage is expected. Respecting the permissible operating
temperature at the conductor of +90 C permits a higher current carrying capacity than PVC insulated power distribution cables.
= The productconformsto the EC Low-Voltage Directive 2006/95/EG.



No.cores x
cross-sec.
mm
1 x 16
1 x 25
1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
1 x 150
1 x 150
1 x 240
1 x 300
1 x 400
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
4 x 95
4 x 120
4 x 150
4 x 185
4 x 240

Outer
Alu weight
approx. mm kg/km
re
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm

11,5
12,5
13,5
15,5
17,0
19,0
20,5
23,0
25,5
28,5
30,0
34,0
21,5
26,0
27,5
30,0
34,0
39,0
42,5
47,5
52,0
58,0

47,0
73,0
102,0
145,0
203,0
276,0
348,0
435,0
537,0
696,0
870,0
1160,0
186,0
290,0
406,0
580,0
812,0
1102,0
1392,0
1740,0
2146,0
2784,0

Weight
approx.
kg/km
98,0
150,0
241,0
357,0
409,0
570,0
590,0
804,0
978,0
1253,0
1394,0
1890,0
750,0
950,0
1120,0
1251,0
1548,0
2030,0
2400,0
3030,0
3650,0
4800,0

J type
Part no.
33113
33114
33115
33116
33117
33118
33119
33120
33121
33122
33123
33124
33137
33138
33139
33140
33141
33142
33143
33144
33145
33146

AWG-No.
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil

O type
Part no.
33125
33126
33127
33128
33129
33130
33131
33132
33133
33134
33135
33136
33147
33148
33149
33150
33151
33152
33153
33154
33155
33156

AWG-No.
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil

Dimensions and specifications may be changed without prior notice. (RQ01)

Q 11
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NYCY power cable, 0,6/1kV, VDE approved, with concentric copper conductor


Technical data

Cable structure

Properties

Power and control cable to DINVDE0276


part603, HD603S1 and IEC60502
7 cores and above to DINVDE0276
part627, HD627S1 and IEC60502
Temperature range
flexing -5 C to +50 C
fixed installation -40 C to +70 C
Permissible operating temperature
at conductor +70 C
Permissible short circuit temperature
+160 C (short circuit duration 5 sec.)
Nominal voltage U0/U 0,6/1 kV
Test voltage 4 kV
Max. permissible tensile stress
with cable grip for Cu-conductor
= 50 N/mm
Minimum bending radius
for single core approx. 15x cable
for multi core approx. 12x cable
Power ratings table
see Technical Informations
Caloric load values
see Technical Informations

Plain copper solid conductor as per


VDE0295 cl.1, BS6360 cl.1, IEC60228 and
HD383
PVC core insulation, DIV4 to HD603.1
Colour coded to VDE0293-308 and HD186
Cores stranded concentrically
Filling compound
Concentric conductor in inner layer of
round copper wires, outer layer with
copper tape
PVC outer sheath, DMV5 to HD603.1
Sheath colour black

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Highest permissible voltage
Direct current systems 1,8 kV
Alternating current systems,
single-phase systems 1,4 kV
Both conductors insulated,
single-phase systems 0,7 kV
One conductor earthed,
three-phase systems 1,2 kV
With concentric conductor and
a cross-section of 240 mm
and above 3,6 kV


Note

re = round solid core.


Available with outer sheath in alternative
colours on request.

Application
Power cables for energy supply are used for industry and distribution boards, power stations, house connecting boxes and street lighting
as well as control cable for the transmission of control impulses and test datas.
Overall, where increased electrical and also mechanical protection are required.
Those cables are installed in open air, in underground, in water, indoors and in cable ducts.
The concentric conductor (C) is allowed to use as PE-, PEN-conductor or as screen.



Part no.
32200
32201
32202
32203
32204
32205
32206
32207
32208
32209
32210
32211
32212
32213
32214
32215
32216
32217
32218
32219
32220
32221
32222
32223

No.cores x
cross-sec.
mm
1x10
1x16
2x1,5
2x2,5
2x4
2x6
2x10
2x16
3x1,5
3x2,5
3x4
3x6
3x10
3x16
4x1,5
4x2,5
4x4
4x6
4x10
4x16
5x1,5
5x2,5
5x4
5x6

Outer
approx. mm
re / 10
re / 16
re / 1,5
re / 2,5
re / 4
re / 6
re / 10
re / 16
re / 1,5
re / 2,5
re / 4
re / 6
re / 10
re / 16
re / 1,5
re / 2,5
re / 4
re / 6
re / 10
re / 16
re / 1,5
re / 2,5
re / 4
re / 6

11,0
12,0
13,0
13,5
15,5
17,0
19,5
20,5
13,5
14,5
16,5
17,5
20,0
23,0
14,5
15,5
17,0
18,5
21,0
23,0
15,0
16,0
19,0
21,0

Cop.
weight
kg/km
216,0
336,0
52,0
80,0
123,0
182,0
312,0
489,0
66,0
104,0
161,0
240,0
408,0
643,0
81,0
128,0
200,0
297,0
504,0
796,0
95,0
152,0
238,0
355,0

Weight
approx. kg/km
280,0
440,0
205,0
270,0
360,0
435,0
590,0
820,0
225,0
290,0
400,0
510,0
850,0
1080,0
260,0
350,0
470,0
590,0
900,0
1250,0
330,0
400,0
560,0
710,0

AWG-No.
8
6
16
14
12
10
8
6
16
14
12
10
8
6
16
14
12
10
8
6
16
14
12
10

Continuation

Q 12
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NYCY power cable, 0,6/1kV, VDE approved, with concentric copper conductor

Part no.
32224
32227
32226
32241
32225
32255
32228
32229
32242
32230
32243
32231
32244
32232
32246
32245
32233
32247
32234
32248
32235
32249
32236
32250
32237
32251
32238
32252
32239
32253
32240
32254

No.cores x
cross-sec.
mm
5x10
7x1,5
7x1,5
7x2,5
7x4
7x6
8x1,5
8x1,5
8x2,5
10x1,5
10x2,5
12x1,5
12x2,5
14x1,5
14x2,5
14x2,5
16x1,5
16x2,5
19x1,5
19x2,5
21x1,5
21x2,5
24x1,5
24x2,5
30x1,5
30x2,5
40x1,5
40x2,5
52x1,5
52x2,5
61x1,5
61x2,5

Outer
approx. mm
re / 10
re / 2,5
re / 1,5
re / 2,5
re / 4
re / 6
re / 1,5
re / 2,5
re / 2,5
re / 2,5
re / 4
re / 2,5
re / 4
re / 2,5
re / 6
re / 4
re / 4
re / 6
re / 4
re / 6
re / 6
re / 10
re / 6
re / 10
re / 6
re / 10
re / 10
re / 10
re / 10
re / 10
re / 10
re / 10

23,0
16,0
16,0
17,5
21,0
24,0
17,0
17,0
18,0
19,0
20,5
20,0
21,0
20,5
22,5
22,0
22,0
23,0
23,0
23,5
24,0
26,0
26,0
28,0
27,0
30,0
30,0
35,0
32,0
38,0
33,0
40,0

Cop.
weight
kg/km
600,0
133,0
124,0
200,0
315,0
470,0
138,0
147,0
224,0
176,0
286,0
205,0
334,0
234,0
403,0
382,0
276,0
451,0
320,0
523,0
369,0
571,0
413,0
696,0
499,0
840,0
696,0
1080,0
869,0
1368,0
998,0
1584,0

Weight
approx. kg/km
1000,0
350,0
320,0
450,0
670,0
790,0
380,0
400,0
510,0
440,0
600,0
500,0
660,0
540,0
800,0
760,0
600,0
910,0
690,0
950,0
810,0
1100,0
860,0
1300,0
1230,0
1610,0
1590,0
2100,0
1820,0
2500,0
2000,0
2850,0

AWG-No.
8
16
16
14
12
10
16
16
14
16
14
16
14
16
14
14
16
14
16
14
16
14
16
14
16
14
16
14
16
14
16
14

Dimensions and specifications may be changed without prior notice. (RQ01)

Q 13
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XCY power cable, 0,6/1 kV, VDE approved, higher current carrying capacity


Technical data

Cable structure

Properties

Power and control cable according to


DINVDE0276 Part603 orHD603S1 and
IEC60502
7 cores and abovein accordance withDIN
0276 Part627 orHD627S1 and IEC60502
Temperature range
Flexing -5 C to +50 C
Fixed installation -40 C to +70 C
Permissible operating temperature
at conductor +90 C
Permissible short circuit temperature
+250 C (short circuit duration 5 sec.)
Nominal voltage
U0/U 0,6/1 kV
Test voltage 4 kV
Max. permissible tensile load
with cable grip = 50 N/mm
Minimum bending radius
Single-core approx. 15x cable
Multi-core approx. 12x cable

Bare copper conductor, single-wire


according to DIN VDE 0295 cl. 1, BS 6360
cl. 1, IEC 60228 or HD 383 
Core insulation from cross-linked
polyethylene compound, DIX3 according
to HD 603.1
Cores stranded in concentric layers
Filling compound
Concentric conductor, inner layer of round
barecopper wires, outer layer of copper
tape as counter helix
PVC outer sheath, DMV6 to HD603.1
Sheath colour black

Self-extinguishing and flame retardant


inaccordancewith VDE 0482-332-1-2, DIN
EN 60332-1-2/ IEC60332-1 (conforms
toDINVDE0472 part804 Test methodB)
The materials used in manufacture are free
of silicone, cadmium and substances that
impair paint wetting 
Highest permissible voltage
Direct current systems 1,8 kV
Three-phase systems
Single-phase systems
Both outer conductors insulated 1,4 kV
Single-phase systems
One outerconductor earthed 0,7 kV
Three-phase systems 1,2 kV


Note

re = round conductor, single-wire


rm = round conductor, multi-wire
sm = sector-shaped conductor, multi-wire


Application
Power distributioncables forindustrial applications and switching systems, power stations, residental connections and street lighting, as
well as control cables for transmitting control pulses and measurements. Whereverincreased electrical and mechanical protection are
required. For installation in underground, in water, outdoors, in concrete and cable ducts. Respecting the permissible operating temperature
at the conductor of +90 C permits a higher current carrying capacity than PVC insulated power distribution cables. The concentric conductor
(C) can be used as aPE or PEN-conductor or as ascreen.
= The product conforms to the EG Low-Voltage Directive 2006/95/EG



Part no.
33212
33213
33214
33215
33216
33217
33218
33219
33220
33221
33222
33223
33224
33225
33226
33227
33228
33229
33230
33231
33232
33233
33234
33235
33236
33237
33238
33239

No.cores x
cross-sec.
mm
2x1,5
2x2,5
2x4
2x6
2x10
2x16
3x1,5
3x2,5
3x4
3x6
3x10
3x16
3x25
3x25
3x35
3x35
3x50
3x50
3x70
3x70
3x95
3x95
3x120
3x120
3x150
3x150
3x185
3x240

Outer
approx. mm
re / 1,5
re / 2,5
re / 4
re / 6
re / 10
re / 16
re / 1,5
re / 2,5
re / 16
re / 6
re / 10
re / 16
rm / 16
rm / 25
sm / 16
sm / 35
sm / 25
sm / 50
sm / 35
sm / 70
sm / 50
sm / 95
sm / 120
sm / 70
sm / 120
sm / 70
sm / 95
sm / 120

13,0
13,5
15,5
17,0
19,5
20,5
13,5
14,5
16,5
17,5
20,0
23,0
25,1
25,0
25,1
25,4
27,3
27,7
32,2
32,7
35,3
35,8
38,9
38,9
43,4
43,4
47,4
52,5

Cop.
weight
kg/km
53,0
80,0
123,0
182,0
312,0
489,0
66,0
104,0
161,0
240,0
408,0
643,0
902,0
1003,0
1190,0
1402,0
1723,0
2000,0
2410,0
2796,0
3296,0
3791,0
4786,0
4236,0
5970,0
5100,0
6383,0
8242,0

Weight
approx. kg/km
205,0
270,0
360,0
435,0
590,0
820,0
225,0
290,0
400,0
510,0
850,0
1080,0
1295,0
1375,0
1441,0
1619,0
1902,0
2107,0
2700,0
3005,0
3588,0
4017,0
4998,0
4534,0
5937,0
5473,0
6831,0
8809,0

AWG-No.
16
14
12
10
8
6
16
14
12
10
8
6
4
4
2
2
1
1
2/0
2/0
3/0
3/0
4/0
4/0
300 kcmil
300 kcmil
350 kcmil
500 kcmil

Continuation

Q 14
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XCY power cable, 0,6/1 kV, VDE approved, higher current carrying capacity

Part no.
33240
33241
33242
33243
33244
33245
33246
33247
33248
33249
33250
33251
33252
33253
33254
33255
33256
33257
33258
33259
33260
33261
33262
33263
33264
33265
33266
33267
33268
33269
33270
33271
33272
33273
33274

No.cores x
cross-sec.
mm
4x1,5
4x2,5
4x4
4x6
4x10
4x16
4x25
4x35
4x50
4x70
4x95
4x120
4x150
5x1,5
5x2,5
5x4
5x6
5x10
5x16
7x1,5
7x2,5
7x4
7x6
10x1,5
10x2,5
12x1,5
12x2,5
14x1,5
14x2,5
19x1,5
19x2,5
30x1,5
30x2,5
40x1,5
40x2,5

Outer
approx. mm
re / 1,5
re / 2,5
re / 4
re / 6
re / 10
re / 16
re / 16
sm / 16
sm / 25
sm / 35
sm / 50
sm / 16
sm / 70
re / 1,5
re / 2,5
re / 4
re / 6
re / 10
re / 16
re / 1,5
re / 2,5
re / 4
re / 6
re / 2,5
re / 4
re / 2,5
re / 4
re / 2,5
re / 6
re / 2,5
re / 6
re / 2,5
re / 10
re / 2,5
re / 10

14,5
15,5
17,0
18,5
21,0
23,0
27,2
27,2
30,6
35,9
39,5
44,5
48,6
15,0
16,0
19,0
21,0
23,0
24,3
16,0
17,5
21,0
24,0
19,0
20,5
20,0
21,0
20,5
22,5
23,0
23,5
27,0
30,0
30,0
35,0

Cop.
weight
kg/km
81,0
128,0
200,0
297,0
504,0
796,0
1142,0
1526,0
2203,0
3082,0
4208,0
5388,0
6540,0
95,0
152,0
238,0
355,0
600,0
931,0
133,0
200,0
315,0
470,0
176,0
286,0
205,0
334,0
234,0
403,0
320,0
523,0
499,0
840,0
696,0
1080,0

Weight
approx. kg/km
260,0
350,0
470,0
590,0
900,0
1250,0
1559,0
1812,0
2413,0
3420,0
4561,0
5819,0
6972,0
330,0
400,0
560,0
710,0
1000,0
1233,0
350,0
450,0
670,0
790,0
440,0
600,0
500,0
660,0
540,0
800,0
690,0
950,0
1230,0
1610,0
1590,0
2100,0

AWG-No.
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
16
14
12
10
8
6
16
14
12
10
16
14
16
14
16
14
16
14
16
14
16
14

Dimensions and specifications may be changed without prior notice. (RQ01)

Q 15
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NYCWY power cable, 0,6/1kV, with concentric copper conductor, VDE approved


Technical data

Cable structure

Properties

Power and control cable to DINVDE0276


part603, HD603S1 and IEC60502
Temperature range
flexing -5 C to +50 C
fixed installation -40 C to +70 C
Permissible operating temperature
at conductor +70 C
Permissible short circuit temperature
+160 C (short circuit duration 5 sec.)
Nominal voltage U0/U 0,6/1 kV
Test voltage 4 kV
Max. permissible tensile stress
with cable grip for Cu-conductor
= 50 N/mm
Minimum bending radius
for single core approx. 15x cable
for multi core approx. 12x cable
Power ratings table
see Technical Informations
Caloric load values
see Technical Informations

Plain copper conductors, as per VDE0295


cl.1 od. cl.2, IEC60228, BS6360 cl.1 and
HD383, solid or stranded versions,
conductor types
10-16 mm round, solid cores (re) alt.
10-25 mm, stranded conductor (rm),
35-240 mm, sector shaped conductor,
stranded (sm)
PVC core insulation, DIV4 to HD603.1
Colour coded to DINVDE0293-308 and
HD186
Cores stranded concentrically
Filling compound
Concentric conductor (Ceander), inner layer
of corrugated copper wires, outer layer
with copper tape
PVC outer sheath, DMV5 to HD603.1
Sheath colour black

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Highest permissible voltage
Direct current systems 1,8 kV
Alternating current systems,
single-phase systems 1,4 kV
Both conductors insulated,
single-phase systems 0,7 kV
One conductor earthed,
three-phase systems 1,2 kV
With concentric conductor and
a cross-section of 240 mm
and above 3,6 kV


Note

At 25 mm = round cables are more


compact thus smaller core .
Available with outer sheath in alternative
colours on request.
re = round solid core;
rm = stranded core;
sm = sectional core.


Application
Power cables for energy supply are used for industry and distribution boards, power stations, house connecting boxes and street lighting
as well as control cable for the transmission of control impulses and test datas.
Overall, where increased electrical and also mechanical protection are required.
Those cables are installed in open air, in underground, in water, indoors and in cable ducts.
The concentric conductor (C) is allowed to use as PE-, PEN-conductor or as screen.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
32260
32261
32262
32263
32264
32265
32274
32275
32266
32267
32276
32268
32277
32269
32278
32270
32279
32271
32280
32272
32281
32273
32282
32283

No.cores x
cross-sec.
mm
2x10
2x16
2x25
3x10
3x16
3x25
3x25
3x35
3x35
3x50
3x50
3x70
3x70
3x95
3x95
3x120
3x120
3x150
3x150
3x185
3x185
3x240
4x10
4x16

Outer
approx. mm
re / 10
re / 16
rm / 25
re / 10
re / 16
rm / 16
rm / 25
sm / 35
sm / 16
sm / 25
sm / 50
sm / 35
sm / 70
sm / 50
sm / 95
sm / 70
sm / 120
sm / 70
sm / 150
sm / 95
sm / 185
sm / 120
re / 10
re / 16

19,0
21,0
24,0
19,5
22,0
26,0
26,0
27,5
27,0
29,5
29,5
33,0
34,0
38,0
38,5
41,0
42,0
45,0
46,0
50,0
51,0
57,0
20,5
23,5

Cop.
weight
kg/km
312,0
489,0
763,0
408,0
643,0
902,0
1003,0
1402,0
1190,0
1723,0
2000,0
2410,0
2796,0
3296,0
3791,0
4236,0
4786,0
5100,0
5970,0
6383,0
7363,0
8242,0
504,0
796,0

Weight
approx. kg/km
650,0
850,0
1210,0
730,0
1000,0
1550,0
1600,0
1850,0
1750,0
2250,0
2450,0
2950,0
3350,0
4100,0
4550,0
5050,0
5550,0
6000,0
6900,0
7550,0
8500,0
9950,0
890,0
1250,0

AWG-No.

8
6
4
8
6
4
4
2
2
1
1
2/0
2/0
3/0
3/0
4/0
4/0
300 kcmil
300 kcmil
350 kcmil
350 kcmil
500 kcmil
8
6

Continuation

Q 16
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NYCWY power cable, 0,6/1kV, with concentric copper conductor, VDE approved

Part no.
32284
32285
32286
32287
32288
32289
32290
32291
32292

No.cores x
cross-sec.
mm
4x25
4x35
4x50
4x70
4x95
4x120
4x150
4x185
4x240

Outer
approx. mm
rm / 16
sm / 16
sm / 25
sm / 35
sm / 50
sm / 70
sm / 70
sm / 95
sm / 120

28,0
29,0
33,0
37,0
43,5
47,0
51,0
56,0
62,5

Cop.
weight
kg/km
1142,0
1526,0
2203,0
3082,0
4208,0
5388,0
6540,0
8159,0
10546,0

Weight
approx. kg/km
1800,0
2050,0
2700,0
3750,0
5000,0
6350,0
7650,0
9350,0
11600,0

AWG-No.
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil

Dimensions and specifications may be changed without prior notice. (RQ01)

Cable Glands
Cable glands for standard applications
Plastic Glands
Cable Glands of Brass
Accessories
Cable glands for special application conditions
for electromagnetic compatibility EMC
for rugged applications and special chemical resistance
for high temperature use
for explosive areas
for special mounting conditions
for special pressure conditions

You can nd cable glands in our catalogue Cable Accessories.

Q 17
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NAYCWY power cable, 0,6/1kV, with concentric copper conductor, VDE approved


Technical data

Cable structure

Properties

Power and control cable to DINVDE0276


part603, HD603S1 and IEC60502
Temperature range
Flexing -5 C to +50 C
Fixed installation -40 C to +70 C
Permissible operating temperature
At conductor +70 C
Permissible short circuit temperature
+160 C (short circuit duration 5 sec.)
Nominal voltage U0/U 0,6/1 kV
Test voltage 4 kV
Max. permissible tensile load
with cable grip = 30 N/mm
Minimum bending radius
Approx. 12x cable

Aluminium conductor according to DIN VDE


0295 cl. 1, IEC 60228, BS 6360 cl. 1 or HD
383
16-25 mm round conductor
single wire (re) or 35-240 mm
sector shaped conductor,multi-wire (sm)
PVC core insulation, DIV4 to HD603.1
Colour coded to DINVDE0293-308 and
HD186
Cores stranded concentrically
Filling compound
Concentric conductor (Ceander), inner layer
of corrugated copper wires, outer layer
with copper tape
PVC outer sheath, DMV5 to HD603.1
Sheath colour black

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Highest permissible voltage
Direct current systems 1,8 kV
Alternating current systems
single-phase systems
Both conductors insulated 1,4 kV
single-phase systems
One conductor earthed 0,7 kV
Three-phase systems 1,2 kV
With concentric conductor and
a cross-sectionfrom 240 mm 3,6 kV


Note

re = round conductor, single-wire;


sm = sector-shaped conductor, multi-wire.


Application
Power distribution cables, preferably used for underground installation, primarily in local networks, for industrial applications and switching
systems, power stations. Wherever increased electrical and mechanical protection are required. Installation in water, outdoors, in concrete,
indoors and in cable ducts. The concentric conductor (C) can be used as a PE or PEN conductor or as a screen.The corrugated design
(Ceander) of the concentric conductor permits any number of cable junctions during assembly, without any conductors having to be cut.
This guarantees optimised reliability.
= The product conforms to the EG Low-Voltage Directive 2006/95/EG.



Part no.
32840
32841
32842
32843
32844
32845
32846
32847
32848
32849

No.cores x
cross-sec.
mm
4x16
4x25
4x35
4x50
4x70
4x95
4x120
4x150
4x185
4x240

Outer
approx. mm
re / 16
re / 16
sm / 16
sm / 25
sm / 35
sm / 50
sm / 70
sm / 70
sm / 95
sm / 120

21,5
25,5
27,1
28,2
32,3
35,8
39,2
43,2
48,4
56,0

Cop.
weight
kg/km
182,0
182,0
182,0
283,0
394,0
560,0
780,0
780,0
1056,0
1130,0

Alu weight
kg/km
186,0
290,0
406,0
580,0
814,0
1102,0
1392,0
1740,0
2146,0
2784,0

Weight
approx. kg/km
1250,0
1800,0
2050,0
2700,0
3750,0
5000,0
6350,0
7650,0
9350,0
11600,0

AWG-No.
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil

Dimensions and specifications may be changed without prior notice. (RQ01)

Q 18
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

A-LiY(StE)Y Data transmission cables for petrol stations and refineries with
BAM-test report


Technical data

Cable structure

Properties

Oil- and fuel-resistant data transmission


cables
Temperature range
flexing -5 C to +70 C
fixed installation -30 C to +70 C
Nominal voltage 200 V
Insulation resitance
min. 100 MOhm x km
Minimum bending radius
approx. 12x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Tinned copper conductor, 7 strands


Core insulation of special PVC, according
to DINVDE0207
Black cores with continuous white
numbering
Each single core screened with aluminium/
polyester foil, metal layer at outside
Screened cores in layers with optimal
lay-lenght screenings of each core make
contact mutually
Drain wire, tinned copper 0,75 mm
7 strands
Overall core-filler
Special PVC-outer sheath, oil- and fuel
resistant
Sheath colour black

Tests
Compound characteristic according to
DINVDE0207
Oil- and fuel resistance of sheath:
according to BAM-Specification
Oil-resistance of sheath:
DINISO6722 part1, 4.11,
DINVDE0472 part803 test methodB
Fuel-resistance of sheath:
DINISO6722 part1, 4.12
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
BAM = Federal Institute for Materials
Testing 

Application

These data transmission cables, oil- and fuel-resistant, are used for internal and external wiring applications at petrol pumps, for data
transmission from the pumps to the cash desk and in the installation of video surveillance systems. These cables are also installed directly
in the ground and are resistant to UV radiation.
Special screens over individual cores guarantee good overall screening and ensure an interference-free transmission of control pulses.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
32597
32633

No.cores x
cross-sec.
mm
4x0,75
7x0,75

Outer
Cop.
approx. mm weight
kg/km
9,0
38,0
10,3
60,0

Weight
approx.
kg/km
105,0
150,0

AWG-No.
18
18


Part no.
32599
32634

No.cores x
cross-sec.
mm
8x0,75
12x0,75

Outer
Cop.
approx. mm weight
kg/km
11,0
68,0
12,9
99,0

Weight
approx.
kg/km
169,0
223,0

AWG-No.
18
18

Dimensions and specifications may be changed without prior notice. (RQ01)

Q 19
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Petrol Station Cables (N)YY-J 0,6/1 kV, with BAM-test report




Technical data

Cable structure

Properties

Power and data transmission cable based


on DINVDE0271
Temperature range
flexing -5 C to +50 C
fixed installation -30 C to +70 C
Permissible operating temperature
at conductor +70 C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4 kV
Max. permissible tensile stress
by cable grip for Cu-conductor
= 50 N/mm
Minimum bending radius
approx. 12x cable

Barecopper conductor, solid according to


DINVDE0295 cl.1, BS6360 cl.1 and
IEC60228 cl.1
Core insulation of PVC, compound YI3
according to DINVDE0207 part4
Concentric lay-up of cores
Core identification according to
DINVDE0293-308
PVC outer jacket black1) according to
DINVDE0207 part5

Oil and fuel-resistant according to


DINISO6722
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
VDE0298 part1 shall be observed.


Note

BAM = Federal Institute for Materials


Testing 
1) Version with blue outer jacket availbable
upon request.


Application
Power and data transmission cables are used for outdoor and underground applications, in water and in concrete provided mechanical
damage can be ruled out. These cables are installed for applications such as petrol stations and oil refineries where resistance to oils and
fuels is required.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
32592
32593
32594

No.cores x
cross-sec.
mm
2x1,5
3x1,5
4x1,5

Outer
Cop.
approx. mm weight
kg/km
11,0
29,0
11,5
43,0
12,0
58,0

Weight
approx.
kg/km
180,0
225,0
260,0

AWG-No.
16
16
16


Part no.
32595
32596

No.cores x
cross-sec.
mm
5x1,5
7x1,5

Outer
Cop.
approx. mm weight
kg/km
13,0
72,0
15,5
101,0

Weight
approx.
kg/km
280,0
370,0

AWG-No.
16
16

Dimensions and specifications may be changed without prior notice. (RQ01)

Q 20
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NYKY-J 0,6/1kV with lead sheath, VDE approved




Technical data

Cable structure

Properties

Power and control cable, PVC insulation


and lead inner-sheath to DINVDE0265
Temperature range
flexing -5 C to +50 C
fixed installation -30 C to +70 C
Permissible operating temperature
at conductor +70 C
Permissible short circuit temperature
+160 C (short circuit duration 5 sec.)
Short circuit temperature +160 C
(short circuit duration 5 sec.)
Nominal voltage U0/U 0,6/1 kV
nominal voltage U
for three-phase system 1,0 kV
for one-phase system 1,2 kV
(outer conductor insulated)
for one phase system 0,6 kV
(one outer conductor earthed)
nominal voltage
U0 = between conductor and lead sheath
U = voltage between the outer conductors,
e. g. U0/U for cables:
For three-phase systemU13
For one-phased.c. system, U0 = U
(both outer conductor insulated)
For one-phase andd.c. system U0 = U
(one outer conductor earthed)
operating voltage
the voltage between the conductors of a
current-circuit (or between conductor and
earth) in a given time during undisturbed
operation under specified condition
Test voltage (5 min.) 6,0 kV
Min. permissible bending radius
approx. 12x cable
Power ratings table
see Technical Informations

Bare copper conductor to DINVDE0295,


BS6360, IEC60228 and HD383
Core insulation of PVC, compound type
DIV4 to VDE0276 part603
Core identification to DINVDE0293-308
up to 5 cores coloured
7 cores black with numbering
Green-yellow earth core
Cores stranded concentrically
Overall jacket of soft plastics material, if
exists, permits also as extrusion or taping
or a combination of both
Lead inner-sheath, jointless and enclosed
PVC outer jacket black, DMV5 to
DINVDE0276 part603
Sheath colour black

Advantage
Good coupling resistance due to enclosed
lead sheath is suitable for special
EMC-requirements (Electromagnetic
Compatibility)
Resistant to
Turpentine substitute
Xylol
Fuels
Trichlor
Oils
Petroleum
Toluene
Hydrocarbon
The lead sheath is not permitted to use as
neutral-conductor (N)
If drain-wire exists, only for use as earthing
of lead sheath in a grounding system e.g.
in hazardous areas to DINVDE0165. This
drain-wire is not allowed to install as
protective, neutral or earth conductor


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
re = round solid core;
sm = sectional core.

Application
These cables of PVC insulation and lead inner-sheath are installed everywhere, where the danger of chemical reaction of solvents, energy
fuels, oils, gasolines or of that kind in filling stations particularly in petrol pump areas for carburetor propellants, in refining plants and in
chemical industries are to be caused. Suitable for installation under ground, in water, indoor areas and cable conduits.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
32640
32686
32641
32642
32643
32644
32645
32646
32647
32648
32649
32650
32651
32652

No.cores x
cross-sec.
mm
3 x 1,5
3 x 1,5
3 x 2,5
3x4
3x6
3 x 25
3 x 35
3 x 50
3 x 70
3 x 95
3 x 120
3 x 150
3 x 185
3 x 240

Outer
approx. mm
re
re / 1,5
re
re
re
rm / 16
sm / 16
sm / 25
sm / 35
sm / 50
sm / 70
sm / 70
sm / 95
sm / 120

13,5
14,5
14,8
16,2
17,3
27,8
29,2
32,7
35,8
40,3
43,2
48,8
53,4
59,8

Cop.
weight
kg/km
43,0
57,0
72,0
115,0
173,0
874,0
1162,0
1680,0
2352,0
3216,0
4128,0
4992,0
6240,0
8064,0

Lead
weight
kg/km
427,0
427,0
487,0
555,0
610,0
1290,0
1340,0
1670,0
2020,0
2440,0
2770,0
3530,0
4230,0
5230,0

Weight
approx. kg/km
598,0
610,0
690,0
840,0
990,0
2550,0
3080,0
3850,0
5360,0
6950,0
8235,0
9620,0
11940,0
15380,0

AWG-No.
16
16
14
12
10
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil

Continuation

Q 21
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NYKY-J 0,6/1kV with lead sheath, VDE approved



Part no.
32653
32687
32654
32655
32656
32657
32658
32659
32660
32661
32662
32663
32664
32688
32665
32666
32667
32668
32669
32670
32689
32678
32671
32679
32672
32680
32673
32681
32674
32682
32675
32683
32676
32684
32677
32685

No.cores x
cross-sec.
mm
4 x 1,5
4 x 1,5
4 x 2,5
4x4
4x6
4 x 10
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
4 x 95
5 x 1,5
5 x 1,5
5 x 2,5
5x4
5x6
5 x 10
5 x 16
7 x 1,5
7 x 1,5
7 x 2,5
10 x 1,5
10 x 2,5
12 x 1,5
12 x 2,5
14 x 1,5
14 x 2,5
19 x 1,5
19 x 2,5
24 x 1,5
24 x 2,5
30 x 1,5
30 x 2,5
40 x 1,5
40 x 2,5

Outer
approx. mm
re
re / 1,5
re
re
re
re
re
rm
rm
sm
sm
sm
re
re / 1,5
re
re
re
re
re
re
re / 1,5
re
re
re
re
re
re
re
re
re
re
re
re
re
re
re

14,5
15,3
15,5
17,5
18,5
21,3
24,2
28,5
30,5
33,3
37,5
42,3
15,3
16,4
17,2
19,4
20,2
22,8
26,4
17,2
17,2
18,0
21,3
22,4
21,3
23,2
21,3
24,5
23,0
26,0
27,3
31,0
28,2
32,3
31,4
36,4

Cop.
weight
kg/km
58,0
72,0
96,0
154,0
230,0
384,0
614,0
960,0
1344,0
1920,0
2688,0
3648,0
72,0
86,0
120,0
192,0
288,0
480,0
768,0
101,0
115,0
168,0
144,0
240,0
173,0
288,0
202,0
336,0
274,0
456,0
346,0
576,0
432,0
720,0
576,0
960,0

Lead
weight
kg/km
464,0
464,0
530,0
605,0
665,0
750,0
975,0
1290,0
1340,0
1680,0
2020,0
2440,0
505,0
505,0
580,0
665,0
730,0
930,0
1070,0
545,0
545,0
625,0
680,0
865,0
710,0
940,0
735,0
980,0
900,0
1170,0
1170,0
1370,0
1240,0
1550,0
1390,0
1770,0

Weight
approx. kg/km
650,0
650,0
760,0
960,0
1100,0
1400,0
1910,0
2750,0
3630,0
4580,0
5340,0
7120,0
710,0
780,0
910,0
1090,0
1270,0
1700,0
2231,0
810,0
970,0
1070,0
918,0
1330,0
988,0
1440,0
1100,0
1530,0
1440,0
1680,0
1610,0
2160,0
1830,0
2530,0
2300,0
3310,0

AWG-No.
16
16
14
12
10
8
6
4
2
1
2/0
3/0
16
16
14
12
10
8
6
16
16
14
16
14
16
14
16
14
16
14
16
14
16
14
16
14

Dimensions and specifications may be changed without prior notice. (RQ01)

Q 22
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2HX
N2XCH
JE-H(St)H
JE-H(St)HRH
N2XH-FE 180/E 30
N2XCH-FE 180/E 30
NHXH-FE 180/E 30
NHXCH-FE 180/E 30
N2XH-FE 180/E 90
N2XCH-FE 180/E 90
NHXH-FE 180/E 90
NHXCH-FE 180/E 90
Photo: HELUKABEL

Security Cables

Q 23
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XH power cable, 0,6/1 kV, halogen-free, without functionality




Technical data

Cable structure

Properties

Power and control cable according to


DINVDE0276 part604, HD604 S1 part1
and part5G
Conductor resistance (at 20 C)
according to VDE0295 cl.1 or 2 and
IEC60228 cl.1 or 2 and HD383 cl.1 and
cl.2
Temperature range
during installation -5 C to +50 C
fixed installation -30 C to +90 C
Permissible operating temperature
at conductor 90 C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4 kV
Minimum bending radius
single-core approx. 15x cable
multi-core approx. 12x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Caloric load values
see Technical Informations

Bare copper conductor, single or


multiple-wire, according to DINVDE0295
cl.1 or 2, BS6360 cl.1 or 2 and IEC60228
cl.1 or 2, HD383
Halogen-free core insulation, cross-linked
polyethylene compound 2XI1, to HD604
S1
Colour coding of cores according to
DINVDE0293-308 and HD186
Green-yellow earth-core, 3 cores and above
Cores stranded in layers (for multi-core
cables)
Overall filled inner sheath
covered by filling compound or
wrapped tape
Outer sheath of thermoplastic polyolefine
compound HM4, to HD604 S1
 Sheath colour black
LS0H = Low Smoke Zero Halogen-free.

Halogen-free, no separation of corrosive


or toxic gases
Limited propagation of fire
Low smoke development
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Tests
Flame test to VDE0482-332-3, BS4066
part3/ DINEN60332-3/IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Halogen-free according to DINVDE0482
part267/ DIN EN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to VDE0482
part1034-1+2/ IEC61034-1+2/
DINEN61034-1+2/ BS7622 part1+2
(equivalent DINVDE0472 part816)


Note

rm = round conductor, multiple-wire;


re = round conductor, single-wire.


Application
Halogen-free power cables with enhanced characteristics in case of fire are used for applications where harm to human life and damage to
property must be prevented in the event of fire, e.g. in industrial installations, communal establishments, hotels, airports, underground
stations, railway stations, hospitals department stores, banks, schools theaters, multi-storey buildings, process control centres etc.
Suitable for fixed installation in dry, damp or wet environments, in, above, on and beneath plaster as well as in masonary walls and in concrete.
These cables are suitable for outdoor applications and in underground by using in conduits or tubes.
For the installation in conduit all precautions must be taken that no accumulation of water can occur in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
J type O type
53100
53101
53102
53103
53104
53105
53106
53107
53108
53109
53110
53111
53112
53113
53114
53115
53116
53117
53118
53119
53120
53121
53122

53248
53249
53250
53251
53252
53253
53254
53255
53256
53257
53258
53259
53260
53261
53262
53263
53264
53265
53266
53267
53268
53269
53270

No.cores x
cross-sec.
mm
1 x 4  re
1 x 6  re
1 x 10  re
1 x 16  re
1 x 25  rm
1 x 35  rm
1 x 50  rm
1 x 70  rm
1 x 95  rm
1 x 120  rm
1 x 150  rm
1 x 185  rm
1 x 240  rm
1 x 300  rm
2 x 1,5  re
2 x 2,5  re
2 x 4  re
2 x 6  re
2 x 10  re
2 x 16  re
2 x 25  rm
3 x 1,5  re
3 x 2,5  re

Outer Cop.
approx. weight
mm
kg/km
8,0
39,0
9,0
58,0
9,0
96,0
10,0
154,0
11,0
240,0
12,0
336,0
15,0
480,0
17,0
672,0
19,0
912,0
21,0
1152,0
23,0
1440,0
25,0
1776,0
28,0
2304,0
30,0
2880,0
12,0
29,0
12,2
48,0
13,2
77,0
14,1
115,0
16,2
192,0
17,8
307,0
21,0
480,0
13,0
43,0
14,0
72,0

Weight
approx.
kg/km
68,0
90,0
140,0
190,0
290,0
390,0
510,0
710,0
960,0
1200,0
1480,0
1910,0
2370,0
2970,0
185,0
220,0
275,0
335,0
450,0
620,0
930,0
220,0
280,0

AWG-No.

Part no.
J type O type

12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
16
14
12
10
8
6
4
16
14

53123
53124
53125
53126
53127
53128
53129
53130
53131
53132
53133
53134
53135
53143
53144
53145
53146
53147
53148
53149
53150
53151

53271
53272
53273
53274
53275
53276
53277
53278
53279
53280
53281
53282
53283
53284
53285
53286
53287
53288
53289
53290
53291
53292

No.cores x
cross-sec.
mm
3 x 4  re
3 x 6  re
3 x 10  re
3 x 16  re
3 x 25  rm
3 x 35  sm
3 x 50  sm
3 x 70  sm
3 x 95  sm
3 x 120  sm
3 x 150  sm
3 x 185  sm
3 x 240  sm
4 x 1,5  re
4 x 2,5  re
4 x 4  re
4 x 6  re
4 x 10  re
4 x 16  re
4 x 25  rm
4 x 35  sm
4 x 50  sm

Outer Cop.
approx. weight
mm
kg/km
15,0
115,0
16,0
173,0
18,0
288,0
20,0
461,0
21,8
720,0
24,9
1008,0
25,2
1440,0
29,2
2016,0
32,0
2736,0
34,9
3456,0
39,2
4320,0
44,1
5328,0
49,2
6912,0
13,0
58,0
14,0
96,0
15,0
154,0
16,0
230,0
18,0
384,0
20,0
614,0
25,0
960,0
27,0
1344,0
28,0
1920,0

Weight
approx.
kg/km
350,0
420,0
600,0
770,0
1120,0
1550,0
1750,0
2450,0
3250,0
4000,0
5000,0
6150,0
8000,0
235,0
290,0
370,0
470,0
670,0
930,0
1440,0
1890,0
2300,0

AWG-No.
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
16
14
12
10
8
6
4
2
1

Continuation

Q 24
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XH power cable, 0,6/1 kV, halogen-free, without functionality




Part no.
J type O type
53152
53153
53154
53155
53156
53157
53158
53159
53160
53161
53162
53163
53164
53171
53178
53165
53172
53166
53173
53179
53167
53174
53168
53175
53169
53176
53170
53177

53293
53294
53295
53296
53297
53298
53299
53309
53310
53311
53312
53313
53314
53315
53316
53317
53318
53319
53320
53321
53322
53323
53324
53325
53326
53327
53328
53329

No.cores x
cross-sec.
mm
4 x 70  sm
4 x 95  sm
4 x 120  sm
4 x 150  sm
4 x 185  sm
4 x 240  sm
5 x 1,5  re
5 x 2,5  re
5 x 4  re
5 x 6  re
5 x 10  re
5 x 16  re
7 x 1,5  re
7 x 2,5  re
7 x 4  re
10 x 1,5  re
10 x 2,5  re
12 x 1,5  re
12 x 2,5  re
12 x 4  re
14 x 1,5  re
14 x 2,5  re
19 x 1,5  re
19 x 2,5  re
24 x 1,5  re
24 x 2,5  re
30 x 1,5  re
30 x 2,5  re

Outer Cop.
approx. weight
mm
kg/km
32,0
2668,0
36,0
3648,0
40,2
4608,0
45,8
5760,0
49,5
7104,0
56,0
9216,0
14,5
72,0
16,0
120,0
17,0
192,0
18,5
288,0
21,0
480,0
24,0
768,0
15,5
101,0
17,0
168,0
17,2
269,0
18,5
144,0
20,0
240,0
19,0
173,0
21,0
288,0
21,2
461,0
20,0
202,0
22,0
336,0
22,0
274,0
24,0
456,0
25,0
346,0
27,0
576,0
26,0
432,0
28,0
720,0

Weight
approx.
kg/km
3200,0
4250,0
5350,0
6550,0
8100,0
10550,0
280,0
350,0
450,0
600,0
850,0
1200,0
350,0
370,0
530,0
480,0
500,0
520,0
560,0
800,0
550,0
630,0
700,0
800,0
850,0
990,0
950,0
1180,0

AWG-No.

Part no.
J type O type

2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
16
14
12
10
8
6
16
14
12
16
14
16
14
12
16
14
16
14
16
14
16
14

53136
53137
53138
53139
53140
53141
53142

53330
53331
53332
53333
53334
53335
53336

No.cores x
cross-sec.
mm
3 x 50 / 25  sm
3 x 70 / 35  sm
3 x 95 / 50  sm
3 x 120 / 70  sm
3 x 150 / 70  sm
3 x 185 / 95  sm
3 x 240 / 120  sm

Outer Cop.
approx. weight
mm
kg/km
28,5
1680,0
31,4
2352,0
34,9
3216,0
38,0
4128,0
43,3
4992,0
47,2
6240,0
53,4
8064,0

Weight
approx.
kg/km
2100,0
2800,0
3750,0
4750,0
5750,0
7200,0
9300,0

AWG-No.
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil

Dimensions and specifications may be changed without prior notice. (RQ02)

Q 25
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XCH power cable, 0,6/1kV, halogen-free, with concentric conductor, without


functionality


Technical data

Cable structure

Properties

Power and control cable according to


DINVDE0276 part604, HD604S1 part1
and part5G
Conductor resistance (at 20 C)
according to VDE0295 cl.1 or 2 and
IEC60228 cl.1 or 2 and HD383 cl.1 and
cl.2
Temperature range
during installation -5 C to +50 C
for fixed installation -30 C to +90 C
Permissible operating temperature
at conductor 90 C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4 kV
Minimum bending radius
approx. 12x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Caloric load values
see Technical Informations

Plain Cu wire conductor, single or


multiple-wire, according to DINVDE0295
cl.1 or 2, BS6360 cl.1 or 2 and IEC60228
cl.1 or 2, HD383
Halogen-free core insulation, cross-linked
polyethylene compound 2XI1, to HD604S1
Colour coding of cores according to
DINVDE0293-308 and HD186
Cores stranded in layers (for multi-core
cables)
Overall filled inner sheath
covered by filling compound
or wrapped tape
Concentric conductor of plain Cu wires
Outer sheath of thermoplastic polyolefine
compound HM4, to HD604S1
 Sheath colour black
LS0H = Low Smoke Zero Halogen-free.

Halogen-free, no liberation of corrosive or


toxic gases
Limited propagation of fire
Low smoke development
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Tests
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
(equivalent DINVDE0472 part816)
Flame test to VDE0482-332-3, BS4066
part3/ DINEN60332-3/ IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Halogen-free according to VDE0482
part267/ DINEN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Note
rm = round conductor, multiple-wire;
re = round conductor, single-wire.

Application
The concentric conductor can be used as PE- PEN conductor or as screen. Suitable for fixed installation in dry, damp or wet environments,
in, above, on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable for outdoor applications and in
underground by using in conduits or tubes.
For the installation in conduit all precautions must be taken that no accumulation of water can occur in the pipes
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
53200
53201
53202
53203
53204
53205
53206
53207
53208
53209
53210
53211
53212
53213
53214
53215
53216
53217
53218
53219
53220
53221
53222

No.cores x
cross-sec.
mm
2x1,5 / 1,5  re
2x2,5 / 2,5  re
2x4 / 4  re
2x6 / 6  re
2x10 / 10  re
2x16 / 16  re
3x1,5 / 1,5  re
3x2,5 / 2,5  re
3x4 / 4  re
3x6 / 6  re
3x10 / 10  re
3x16 / 16  re
3x25 / 16  rm
3x35 / 16  rm
3x50 / 25  rm
3x70 / 35  sm
3x95 / 50  sm
3x120 / 70  sm
3x150 / 70  sm
3x185 / 95  sm
3x240 / 120  sm
4x1,5 / 1,5  re
4x2,5 / 2,5  re

Outer
approx.
mm
14,0
15,0
14,0
15,0
16,0
19,1
14,5
15,5
16,5
18,0
20,0
22,5
27,0
27,5
32,3
35,6
39,0
42,0
43,5
47,4
53,5
15,5
16,5

Cop.
weight
kg/km
53,0
81,0
122,0
183,0
311,0
490,0
67,0
104,0
161,0
242,0
408,0
643,0
1001,0
1190,0
2003,0
2794,0
3790,0
4785,0
5100,0
6381,0
8240,0
81,0
129,0

Weight
approx.
kg/km
250,0
280,0
320,0
400,0
560,0
780,0
250,0
320,0
400,0
500,0
750,0
1000,0
1600,0
1900,0
2400,0
3060,0
4200,0
5207,0
5700,0
7150,0
9250,0
300,0
380,0

AWG-No.
16
14
12
10
8
6
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
16
14


Part no.
53223
53224
53225
53226
53227
53228
53229
53230
53231
53758
53759
53760
53761
53232
53239
53246
53233
53240
53234
53241
53247
53235
53242

No.cores x
cross-sec.
mm
4x4 / 4  re
4x6 / 6  re
4x10 / 10  re
4x16 / 16  re
4x25 / 16  rm
4x35 / 16  rm
4x50 / 25  rm
4x70 / 35  sm
4x95 / 50  sm
4x120 / 70  sm
4x150 / 70  sm
4x185 / 95  sm
4x240 / 120  sm
7x1,5 / 2,5  re
7x2,5 / 2,5  re
7x4 / 4  re
10x1,5 / 2,5  re
10x2,5 / 4  re
12x1,5 / 2,5  re
12x2,5 / 4  re
12x4 / 6  re
16x1,5 / 4  re
16x2,5 / 6  re

Outer
approx.
mm
17,5
19,0
21,5
24,5
29,0
29,5
32,5
38,0
43,5
50,5
52,1
57,2
62,6
14,5
15,1
18,1
17,2
18,9
18,4
19,2
22,6
20,0
20,9

Cop.
weight
kg/km
202,0
297,0
504,0
797,0
1142,0
1528,0
2203,0
3082,0
4208,0
5388,0
6540,0
8159,0
10546,0
132,0
200,0
316,0
177,0
287,0
204,0
335,0
528,0
275,0
450,0

Weight
approx.
kg/km
480,0
600,0
850,0
1200,0
1800,0
2100,0
2800,0
3800,0
5100,0
6556,0
7600,0
9370,0
11611,0
320,0
400,0
580,0
420,0
550,0
460,0
610,0
910,0
686,0
805,0

AWG-No.
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
16
14
12
16
14
16
14
12
16
14

Continuation

Q 26
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XCH power cable, 0,6/1kV, halogen-free, with concentric conductor, without


functionality


Part no.
53236
53243
53237
53244
53238
53245

No.cores x
cross-sec.
mm
21x1,5 / 6  re
21x2,5 / 6  re
24x1,5 / 6  re
24x2,5 / 10  re
30x1,5 / 6  re
30x2,5 / 10  re

Outer
approx.
mm
22,6
25,2
23,2
26,1
24,3
28,0

Cop.
weight
kg/km
370,0
572,0
412,0
695,0
500,0
842,0

Weight
approx.
kg/km
766,0
1015,0
800,0
1100,0
930,0
1290,0

AWG-No.
16
14
16
14
16
14

Dimensions and specifications may be changed without prior notice. (RQ02)

Conduits
Corrugated tubes
for standard applications
for lager sizes
scissile corrugated tubes
conduit glands
High exible conduits
plastic conduits with spiral spring
metal conduits
conduits glands
Conduit for heavy mechanical duty
metal conduits with plastic sheat
plastic conduits
conduits glands for metal conduits

You can nd conduits in our catalogue Cable Accessories.

Q 27
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JE-H(St)H Bd FE 180/E 30 bis E 90 (orange), halogen-free




Technical data

Cable structure

Properties

Flame retardant, halogen-free installation


cable, adapted to DINVDE0815
Insulation integrity 180 min tested to
DINVDE0472 part814 and IEC60331
Functionality E30 to E90 min
(dependant on corresponding installation
technique)
Loop resistance max. 73,2 Ohm/km
Temperature range
flexing -5 C to +50 C
fixed installation -30 C to +70 C
Operating top level voltage
225 V (not for purposes of high current
and power installation)
Test voltage
core/core 500 V
core/screen 2000 V
Insulation resistance
min. 100 MOhm x km
Mutual capacitance
max. 120 nF/km at 800 Hz
(this values may be extended at 20% with
a make-up up to 4 pairs)
Capacitance unbalance
max. 200 pF/100 m (20% of the values, but
one value up to 400 pF is allowed)
Minimum bending radius
approx. 6x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Caloric load values
see Technical Informations

Bare copper conductor, solid,0,8mm


Special core insulation halogen-free,
cross-linked polymer to DINVDE0207
part23, HI1 flame retardant (E90 with
special foil wrapping over conductor)
Core identification with colour rings and
ring-groups to DINVDE0815
Cores twisted to pairs, 4 pairs consist to
unit, several units stranded to layers
Units identified by numbered tape
Core wrapping with special polyester and
glass-fibre tape
Screening with alu-laminated polyester tape
and solid tinned copper drain wire
0,8mm
Halogen-free outer jacket, flame retardant
to DINVDE0207 part24 HM2
 Jacket colour orange
Tests
Flame test to VDE0482-332-3, BS4066
part3/ DINEN60332-3/ IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC 60754-2 (equivalent
DINVDE0472 part813)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
 (equivalent DINVDE0472 part816)
LS0H = Low Smoke Zero Halogen-free.

No fire propagation
Low smoke density
FE180: Insulation integrity for 180
minutes.
Tests to DINVDE0472 part814IEC60331.
Insulation integrity under direct flame
propagation for the test period of
180minutes.
E30: Functionality of electrical cable
systems for minimum 30minutes. Test to
DIN4102 part12.
The functionality for 30 minutes assures
when persons and animals are to be saved
from a burning building. 30 minutes
secures the functional performance of the
fire warning and alarm systems, safety and
spare lighting, passenger lifts with
evacuation circuits, except the cables which
are installed within the ladder shafts and
engine rooms.
E90: Functionality of electrical cable
systems for minimum 90 minutes. Test
method to DIN4102 part12.
The functionality for 90 minutes assures
the functional performance of
water-pressure-rising stations for the
supply to avoid smoke and heat in
safety-stairs and inner rooms, ladder shafts
and engine rooms for fire brigade lifts,
emergency lifts for sickbeds in hospitals
and the fire brigade lifts.


Note

E 30 to E 90
Functionality (burning behaviour) is
dependant on corresponding installation
technique.
Not for purposes of high current and
power installation as well as underground
laying.


Application
Flame resistant, halogen-free, static screened installation cables for telecommunication purpose. The static screen prevents strong interference
impulse. Suitable for fixed installation everywhere, where in case of fire human life and material assets are to be protected and a safety
conciousness take a special significance, e.g. in industrial complexes, public buildings, hotels, airports, under ground railway networks,
hospitals.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Functionality E 30 to E 90
Part no.
34081
34082
34083
34084
34085
34086
34087
34088
34089

No.pairs x
cross-sec.
mm
2 x 2 x 0,8
4 x 2 x 0,8
8 x 2 x 0,8
12 x 2 x 0,8
16 x 2 x 0,8
20 x 2 x 0,8
32 x 2 x 0,8
40 x 2 x 0,8
52 x 2 x 0,8

Outer
approx.
mm
7,4
10,8
16,9
18,5
20,1
22,2
29,1
34,2
37,3

Cop.
weight
kg/km
25,0
45,0
85,0
126,0
166,0
206,0
326,0
407,0
529,0

Weight
approx.
kg/km
74,0
127,0
300,0
336,0
426,0
529,0
859,0
1094,0
1280,0

Functionality E 30
Part no.
34148
34149
34150
34151
34152
34153
34154
34155
34156

No.pairs x
cross-sec.
mm
2 x 2 x 0,8
4 x 2 x 0,8
8 x 2 x 0,8
12 x 2 x 0,8
16 x 2 x 0,8
20 x 2 x 0,8
32 x 2 x 0,8
40 x 2 x 0,8
52 x 2 x 0,8

Outer
approx.
mm
7,5
9,3
11,4
13,0
15,7
16,5
20,3
23,4
25,2

Cop.
weight
kg/km
25,0
45,0
85,0
126,0
166,0
206,0
326,0
407,0
529,0

Weight
approx.
kg/km
74,0
127,0
300,0
336,0
426,0
529,0
859,0
1094,0
1280,0

Dimensions and specifications may be changed without prior notice. (RQ02)

Q 28
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JE-H(St)H Bd fire warning cable, FE 180/E 30 to E 90 (red), halogen-free




Technical data

Cable structure

Properties

Flame retardant, halogen-free installation


cable, adapted to DINVDE0815
Insulation integrity 180 min, tested to
DINVDE0472 part814 and IEC60331
Functionality (burning behaviour)
E 30 to E 90 min (dependant on
corresponding installation technique)
Loop resistance
max. 73,2 Ohm/km
Temperature range
flexing -5 C to +50 C
fixed installation -30 C to +70 C
Operating voltage (peak voltage)
225 V (not for purposes of high current
and power installation)
Test voltage
core/core 500 V
core/screen 2000 V
Insulation resistance
min. 100 MOhm x km
Mutual capacitance
max. 120 nF/km at 800 Hz
(this values may be extended at 20% with
a make-up up to 4 pairs)
Capacitance unbalance
max. 200 pF/100 m (20% of the values, but
one value up to 400 pF is allowed)
Minimum bending radius
approx. 6x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Caloric load values
see Technical Informations

Bare copper conductor, solid,0,8mm


Special core insulation halogen-free,
cross-linked polymer to DINVDE0207
part23, HI1, flame retardant (E90 with
special foil wrapping over conductor)
Core identification with colour rings and
ring-groups to DINVDE0815
Cores twisted to pairs, each 4 pairs consist
to unit, several units stranded to layers
Units identified with numbered tape
Core wrapping with special polyester and
glass-fibre tape
Screening with alu-laminated polyester tape
and solid copper drain wire 0,8mm
Halogen-free outer jacket, flame retardant
to DINVDE0207 part24, HM2
Jacket colour red, RAL3000 with imprint
 "BRANDMELDEKABEL"
Tests
Flame test to VDE0482-332-3, BS4066
part3/ DINEN60332-3/ IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
 (equivalent DINVDE0472 part816)
LS0H = Low Smoke Zero Halogen-free.

No fire propagation
Low smoke density
Not for purposes of high current and
power installation as well as underground
laying
FE 180: Insulation integrity for 180
minutes. Tests to DIN VDE 0472 part 814
IEC 60331.
Insulation integrity under direct flame
propagation for the test period of 180
minutes.
E 30: Functionality of electrical cable
systems for minimum 30 minutes. Test to
DIN 4102 part 12.
The functionality for 30 minutes assures
when persons and animals are to be saved
from a burning building. 30 minutes
secures the functional performance of the
fire warning and alarm systems, safety and
spare lighting, passenger lifts with
evacuation circuits, except the cables which
are installed within the ladder shafts and
engine rooms.
E 90: Functionality of electrical cable
systems for minimum 90 minutes. Test
method to DIN 4102 part 12.
The functionality for 90 minutes assures
the functional performance of
water-pressure-rising stations for the
supply to avoid smoke and heat in
safety-stairs and inner rooms, ladder shafts
and engine rooms for fire brigade lifts,
emergency lifts for sickbeds in hospitals
and the fire brigade lifts.


Note

E 30 to E 90
Functionality (burning behaviour) is
dependant on corresponding installation
technique.


Application
Flame resistant, halogen-free, static screened installation cables for telecommunication purpose. The static screen prevents strong interference
impulse. Suitable for fixed installation everywhere, where in case of fire human life and material assets are to be protected and a safety
conciousness take a special significance, e.g. in industrial complexes, public buildings, hotels, airports, under ground railway networks,
hospitals.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
34091
34092
34093
34094
34095
34096
34097
34098
34099

No.pairs x
cross-sec.
mm
2 x 2 x 0,8
4 x 2 x 0,8
8 x 2 x 0,8
12 x 2 x 0,8
16 x 2 x 0,8
20 x 2 x 0,8
32 x 2 x 0,8
40 x 2 x 0,8
52 x 2 x 0,8

Outer
approx.
mm
7,4
10,8
16,9
18,5
20,1
22,2
29,1
34,2
37,3

Cop.
weight
kg/km
25,0
45,0
85,0
126,0
166,0
206,0
326,0
407,0
529,0

Weight
approx.
kg/km
74,0
127,0
300,0
336,0
426,0
529,0
859,0
1094,0
1280,0

Functionality E30
Part no.
34157
34158
34159
34160
34161
34162
34163
34164
34165

No.pairs x
cross-sec.
mm
2 x 2 x 0,8
4 x 2 x 0,8
8 x 2 x 0,8
12 x 2 x 0,8
16 x 2 x 0,8
20 x 2 x 0,8
32 x 2 x 0,8
40 x 2 x 0,8
52 x 2 x 0,8

Outer
approx.
mm
7,5
9,3
11,4
13,0
15,7
16,5
20,3
23,4
25,2

Cop.
weight
kg/km
25,0
45,0
85,0
126,0
166,0
206,0
326,0
407,0
529,0

Weight
approx.
kg/km
67,0
103,0
168,0
237,0
303,0
361,0
553,0
699,0
865,0

Dimensions and specifications may be changed without prior notice. (RQ02)

Q 29
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

JE-H(St)HRH Bd fire warning cable, FE 180/E 30 to E 90, halogen-free




Technical data

Cable structure

Properties

Special insulation for cores and outer jacket


according to DINVDE0815. Compound
to DINVDE0207 part23 HI1, flame
resistant
Insulation integrity 180min tested to
DINVDE0472 part814 and IEC60331
Functionality E 90 min
Loop resistance max. 73 Ohm/km
Operating voltage (peak voltage)
max. 225 V (not for purposes of high
current and power installation)
Test voltage
core/core 500 V
core/screen 2000 V
Insulation resistance
min. 100 MOhm x km
Mutual capacitance
max. 120 nF/km at 800 Hz
Minimum bending radius
approx. 6x cable
Caloric load values
see Technical Informations

Bare solid copper conductor, 0,8mm


Special core insulation halogen-free,
cross-linked polymer to DINVDE0207
part23, HI1, flame retardant (E90 with
special foil wrapping over conductor)
2 cores twisted to pair and each 4 pairs
layed up in bunches, the bunches stranded
in layers
Glass-fibre taped
Screening with alu-laminated polyester tape
and solid copper drain wire 0,8mm
Inner sheath, flame retardant polyolefin
compound to DIN VDE 0207 part 24 HM3
Galvanized steel wire braided screen
Special outer jacket HM2 to DINVDE0207
part24, flame resistant
Outer jacket red (RAL3000) with imprint
 "BRANDMELDEKABEL"
Tests
Flame test to VDE0482-332-3, BS4066
part3/ DINEN60332-3/ IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
 (equivalent DINVDE0472 part816)
LS0H = Low Smoke Zero Halogen-free.

No fire propagation
Low smoke density
Not for purposes of high current and
power installation as well as underground
laying
FE180: Insulation integrity for 180
minutes. Tests to DINVDE0472 part814
IEC60331.
Insulation integrity under direct flame
propagation for the test period of 180
minutes.
E30: Functionality of electrical cable
systems for minimum 30 minutes. Test to
DIN4102 part12.
The functionality for 30 minutes assures
when persons and animals are to be saved
from a burning building. 30minutes
secures the functional performance of the
fire warning and alarm systems, safety and
spare lighting, passenger lifts with
evacuation circuits, except the cables which
are installed within the ladder shafts and
engine rooms.
E90: Functionality of electrical cable
systems for minimum 90 minutes. Test
method to DIN4102 part12.
The functionality for 90 minutes assures
the functional performance of
water-pressure-rising stations for the
supply to avoid smoke and heat in
safety-stairs and inner rooms, ladder shafts
and engine rooms for fire brigade lifts,
emergency lifts for sickbeds in hospitals
and the fire brigade lifts.


Note

E 30 to E 90
Functionality is dependant on installation
technique.


Application
Flame resistant, halogen-free, static screened installation cables for telecommunication purpose. The static screen prevents strong interference
impulse.
Suitable for fixed installation everywhere, where in case of fire human life and material assets are to be protected and a safety conciousness
take a special significance, e.g. in industrial complexes, public buildings, hotels, airports, under ground railway networks, hospitals.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
34075
34076
34077
34078
34079

No.pairs x
cross-sec.
mm
2 x 2 x 0,8
4 x 2 x 0,8
8 x 2 x 0,8
12 x 2 x 0,8
16 x 2 x 0,8

Outer
approx.
mm
10,5
14,8
21,1
22,7
25,0

Cop.
weight
kg/km
25,0
45,0
85,0
126,0
166,0

Weight
approx.
kg/km
150,0
275,0
545,0
602,0
734,0


Part no.
34080
34072
34073
34074

No.pairs x
cross-sec.
mm
20 x 2 x 0,8
32 x 2 x 0,8
40 x 2 x 0,8
52 x 2 x 0,8

Outer
approx.
mm
26,9
35,0
41,0
44,0

Cop.
weight
kg/km
206,0
326,0
407,0
529,0

Weight
approx.
kg/km
870,0
1360,0
1800,0
2038,0

Dimensions and specifications may be changed without prior notice. (RQ02)

Q 30
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XH-FE 180/E 30 security cable, halogen-free, 0,6/1kV, with improved


fire characteristics


Technical data

Cable structure

Properties

Halogen-free security cable with improved


characteristics in the case of fire to
DINVDE0266
Insulation integrity
180 minutes to DINVDE0472 part814
Functionality
30 minutes to DINVDE4102 part12
Temperature range
-30 C to +70 C
Permissible operating temperature
at conductor +90 C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4000 V
Minimum bending radius
approx. 15x cable
Radiation resistance
up to 200x106 cJ/kg (up to 200 Mrad)
Caloric load values
see Technical Informations


Bare copper conductor, solid or stranded,


to DINVDE0295 cl.1 or cl.2, BS6360 cl.1
or 2, IEC60228 cl.1/2, HD383
Core with double insulation: Flame
retardant MICA-tapeover conductor Core
insulation with cross-linked polyethylene,
compound type 2XI1 to DINVDE0276
part604
Cores colour coding to DINVDE0293-308
and 0276 part604
Green-yellow earth-core, 3 cores and above
Cores stranded in layers Overall core
covering, halogen-free filling compound,
pressed
Outer jacket of thermoplastic halogen-free
polyolefine, compound type HM4 to
DINVDE0276 part604, flame
retardant,colour orange 
Tests
Flame test to VDE0482-332-3, BS4066
part3/ DINEN60332-3/ IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Halogen-free according to DINVDE0482
part267/ DIN EN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
(equivalent DINVDE0472 part816)
Insulation integrity under flame
propagation to VDE0472 part814
IEC60331, Burning behaviour in fire
(functionality) of the complete cable
system to DIN4102 part12 (30minutes)
 LS0H = Low Smoke Zero Halogen-free.

Halogen-free; no evolution of corrosive


and toxic gases
Flame retardant
Hardly flammable
Self-extinguished and fire resistant
No flame propagation, therefore security
from fire
Low smoke density, no darkening of
emergency exits without hindering the fire
extinguishing works
Toxicological harmless
No self-ignition
Maintenance of functionality during the
increased current load
FE 180: Insulation integrity for 180
minutes. Tests to DINVDE0472 part814
IEC60331.
Insulation integrity under direct flame
propagation for the test period of 180
minutes.
E 30: Functionality of electrical cable
systems for minimum 30 minutes. Test to
DIN4102 part12. This fulfils the demands
of technical guide lines for fire protection
(supplement 1 to DINVDE0108 part1).
The functionality for 30 minutes assures
when persons and animals are to be saved
from a burning building. 30 minutes
secures the functional performance of the
fire warning and alarm systems, safety and
spare lighting, passenger lifts with
evacuation circuits, except the cables which
are installed within the ladder shafts and
engine rooms.


Note

rm = round conductor, multiple-wire;


re = round conductor, single-wire.

Application
Security cables are ideal for use everywhere, where in case of fire human life and material assets are to be protected and safety conciousness
take a special significance, e.g. in industrial complexes, power stations, communal establishment, hotels, airports, underground railway
networks, hospitals and outpatients clinic (DIN VDE 0107), department stores, data processing centres, theaters, cinemas, in multi-storey
buildings, public gatherings, schools etc. (DIN VDE 0108), mining works, offshore plants, leading centres, traffic communication, emergency
power supply and alarm systems. The cables are suitable for fixed installation in dry and moist rooms, in, above, on and beneath plaster as
well as in masonary walls and in concrete.
For the installation in conduit all precautions must be taken that no accumulation of water can occur in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
52058
52059
52060
52061
52062

No.cores x
cross-sec.
mm
1x4  re
1x6  re
1x10  re
1x16  re
1x25  rm

Outer
approx.
mm
8,0
9,0
10,0
10,5
13,0

Cop.
weight
kg/km
38,0
58,0
96,0
154,0
240,0

Weight
approx.
kg/km
155,0
190,0
215,0
240,0
380,0

AWG-No.
12
10
8
6
4


Part no.
52063
52064
52065
52066
52067

No.cores x
cross-sec.
mm
1x35  rm
1x50  rm
1x70  rm
1x95  rm
1x120  rm

Outer
approx.
mm
14,0
15,5
17,5
19,5
21,0

Cop.
weight
kg/km
336,0
480,0
672,0
912,0
1152,0

Weight
approx.
kg/km
460,0
590,0
820,0
1090,0
1350,0

AWG-No.
2
1
2/0
3/0
4/0

Continuation

Q 31
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XH-FE 180/E 30 security cable, halogen-free, 0,6/1kV, with improved


fire characteristics

Part no.
52068
52069
52070
52071
52072
52073
52074
52075
52076
52077
52078
52079
52080
52081
52082
52083
52084
52088
52085
52089
52086
52090
52087
52091
52092

No.cores x
cross-sec.
mm
1x150  rm
1x185  rm
1x240  rm
2x1,5  re
2x2,5  re
2x4  re
2x6  re
2x10  re
2x16  re
2x25  rm
3G1,5  re
3G2,5  re
3G4  re
3G6  re
3G10  re
3G16  re
3G25  rm
3G25 / 16  rm
3G35  rm
3G35 / 16  rm
3G50  rm
3G50 / 25  rm
3G70  rm
3G70 / 35  rm
3G95 / 50  rm

Outer
approx.
mm
23,0
25,0
29,0
11,5
12,0
13,0
14,0
15,5
17,5
22,0
12,0
12,5
13,5
14,5
16,5
18,5
23,5
22,5
26,0
28,0
29,0
32,0
34,0
35,0
40,0

Cop.
weight
kg/km
1440,0
1776,0
2304,0
29,0
48,0
77,0
115,0
192,0
307,0
480,0
43,0
72,0
115,0
173,0
288,0
461,0
720,0
874,0
1080,0
1162,0
1440,0
1680,0
2016,0
2352,0
3216,0

Weight
approx.
kg/km
1650,0
2030,0
2590,0
170,0
190,0
260,0
310,0
430,0
600,0
930,0
170,0
220,0
290,0
370,0
530,0
760,0
1160,0
1430,0
1560,0
1810,0
2030,0
2340,0
2890,0
3190,0
4350,0

AWG-No.
300 kcmil
350 kcmil
500 kcmil
16
14
12
10
8
6
4
16
14
12
10
8
6
4
4
2
2
1
1
2/0
2/0
3/0


Part no.
52093
52094
52095
52096
52097
52614
52615
52616
52617
52628
52629
52383
52432
52433
52434
52618
52619
52620
52621
52622
52623
52626
52627
52624
52625

No.cores x
cross-sec.
mm
3G120 / 70  rm
3G150 / 70  rm
3G185 / 95  rm
4G1,5  re
4G2,5  re
4G4  re
4G6  re
4G10  re
4G16  re
4x25  rm
4x35  rm
4x50  rm
4x70  rm
4x95  rm
4x120  re
5G1,5  re
5G2,5  re
5G4  re
5G6  re
5G10  re
5G16  re
5x25  rm
5x35  rm
7G1,5  re
12G1,5  re

Outer
approx.
mm
45,0
48,5
54,0
12,5
13,0
13,0
14,5
16,0
18,0
23,6
26,4
29,5
34,6
39,0
43,5
12,0
13,0
14,5
15,5
18,0
20,0
24,5
33,5
13,0
16,5

Cop.
weight
kg/km
4128,0
4992,0
6240,0
58,0
96,0
154,0
230,0
384,0
614,0
960,0
1344,0
1920,0
2688,0
3648,0
4608,0
72,0
120,0
192,0
288,0
480,0
768,0
1200,0
1680,0
101,0
173,0

Weight
approx.
kg/km
5550,0
6560,0
8240,0
210,0
260,0
310,0
410,0
620,0
900,0
1600,0
2050,0
2761,0
3785,0
5010,0
6135,0
210,0
280,0
380,0
510,0
760,0
1120,0
1840,0
2510,0
250,0
390,0

AWG-No.
4/0
300 kcmil
350 kcmil
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
16
14
12
10
8
6
4
2
16
16

Dimensions and specifications may be changed without prior notice. (RQ02)

Q 32
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XCH-FE 180/E 30 security cable, halogen-free, 0,6/1kV, with improved


fire characteristics


Technical data

Cable structure

Properties

Halogen-free security cable with improved


characteristics in the case of fire to
DINVDE0266
Insulation integrity
180 minutes to DINVDE0472 part814
Functionality
30 minutes to DINVDE4102 part12
Temperature range
-30 C to +70 C
Permissible operating temperature
at conductor +90 C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4000 V
Minimum bending radius
approx. 15x cable
Radiation resistance
up to 200x106 cJ/kg (up to 200 Mrad)
Caloric load values
see Technical Informations
Tests
Flame test to VDE 0482 part 266-2, BS 4066
part 3/ DIN EN 50266-2/ IEC 60332-3
(equivalent DIN VDE 0472 part 804 test
method C)
Corrosiveness of combustion gases
according to VDE 0482 part 267/ DIN EN
50267-2-2/ IEC 60754-2 (equivalent DIN VDE
0472 part 813)
Halogen-free according to VDE 0482 part
267/ DIN EN 50267-2-1/ IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density according to VDE 0482 part
1034-1+2/ IEC 61034-1+2/ DIN EN
61034-1+2/ BS 7622 part 1+2 (equivalent
DIN VDE 0472 part 816)
Insulation integrity under flame
propagation to VDE 0472 part 814 IEC
60331 Funktionserhalt von Kabelanlagen
nach DIN 4102 part 12 (30 min)

Bare copper conductor, solid or stranded,


to DINVDE0295 cl.1 or cl.2, BS6360 cl.1
or2, IEC60228 cl.1 or 2, HD383
Core with double insulation:
Flame retardant MICA-tape over conductor
Core insulation with cross-linked
polyethylene, compound type 2XI1 to
DINVDE0276 part604
Cores colour coding to DINVDE0293-308
and 0276 part604
Cores stranded in layers
Overall core covering, halogen-free filling
compound, pressed
Concentric conductor of Cu-bare wires with
helix of copper tape
Outer jacket of thermoplastic halogen-free
polyolefine, compound type HM4 to
DINVDE0276 part604, flame retardant,
 colour orange
LS0H = Low Smoke Zero Halogen-free.


Halogen-free; no evolution of corrosive


and toxic gases
Flame retardant
Hardly flammable
Self-extinguished and fire resistant
No flame propagation, therefore security
from fire
Low smoke density, no darkening of
emergency exits without hindering the fire
extinguishing works
Toxicological harmless
No self-ignition
Maintenance of functionality during the
increased current load
FE180: Insulation integrity for 180
minutes. Tests to DINVDE0472 part814
IEC60331.
Insulation integrity under direct flame
propagation for the test period of
180minutes.
E 30: Functionality of electrical cable
systems for minimum 30minutes. Test
method to DIN4102 part12. This fulfils the
demands of technical guide lines for fire
protection (supplement1 to DINVDE0108
part1).
The functionality for 30minutes assures
when persons and animals are to be saved
from a burning building. 30minutes
secures the functional performance of the
fire warning and alarm systems, safety and
spare lighting, passenger lifts with
evacuation circuits, except the cables which
are installed within the ladder shafts and
engine rooms.


Note

rm = round conductor, multiple-wire;


re = round conductor, single-wire.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a special significance,
e.g. in industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals and
outpatients clinic (DINVDE0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings,
schools etc. (DINVDE0108), mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm
systems. Suitable for fixed installation in dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete.
These cables are suitable for outdoor applications and in underground by using in conduits or tubes.
Additionally valid also DINVDE0298 part1 and 2.
For the installation in conduit all precautions must be taken that no accumulation of water can occur in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
52098
52099
52100

No.cores x
cross-sec.
mm
2x1,5 / 1,5  re
2x2,5 / 2,5  re
2x4 / 4  re

Outer
approx.
mm
13,0
14,0
15,0

Cop.
weight
kg/km
52,0
80,0
123,0

Weight
approx.
kg/km
200,0
250,0
310,0

AWG-No.
16
14
12


Part no.
52101
52102
52103

No.cores x
cross-sec.
mm
2x6 / 6  re
2x10 / 10  re
3x1,5 / 1,5  re

Outer
approx.
mm
16,0
17,5
13,0

Cop.
weight
kg/km
182,0
312,0
66,0

Weight
approx.
kg/km
400,0
570,0
220,0

AWG-No.
10
8
16

Continuation

Q 33
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XCH-FE 180/E 30 security cable, halogen-free, 0,6/1kV, with improved


fire characteristics

Part no.
52104
52105
52106
52107
52108
52109
52110
52111
52112
52113
52114
52115
52116
52117
52118
52119

No.cores x
cross-sec.
mm
3x2,5 / 2,5  re
3x4 / 4  re
3x6 / 6  re
3x10 / 10  re
3x16 / 16  re
3x25 / 16  rm
3x35 / 16  rm
3x50 / 25  rm
3x70 / 35  rm
3x95 / 50  rm
3x120 / 70  rm
3x150 / 70  rm
3x185 / 95  rm
3x240 / 120  rm
4x1,5 / 1,5  re
4x2,5 / 2,5  re

Outer
approx.
mm
14,0
15,5
16,5
18,5
21,0
25,5
29,0
31,5
36,5
40,0
46,0
50,5
55,0
61,5
15,0
16,0

Cop.
weight
kg/km
104,0
161,0
240,0
408,0
643,0
902,0
1190,0
1723,0
2410,0
3296,0
4236,0
5100,0
6383,0
8242,0
81,0
128,0

Weight
approx.
kg/km
270,0
360,0
470,0
680,0
960,0
1390,0
1720,0
2320,0
3260,0
4310,0
5520,0
6620,0
8180,0
10620,0
260,0
310,0

AWG-No.
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
16
14


Part no.
52120
52121
52122
52123
52124
52125
52126
52127
52128
52129
52130
52131
52132
52133
52134

No.cores x
cross-sec.
mm
4x4 / 4  re
4x6 / 6  re
4x10 / 10  re
4x16 / 16  re
4x25 / 16  rm
4x35 / 16  rm
4x50 / 25  rm
4x70 / 35  rm
4x95 / 50  rm
4x120 / 70  rm
4x150 / 70  rm
4x185 / 95  rm
4x240 / 120  rm
7x1,5 / 2,5  re
30x1,5 / 6  re

Outer
approx.
mm
17,0
18,0
20,0
22,5
28,0
30,5
32,0
39,5
43,5
49,5
55,5
60,0
68,0
16,5
29,0

Cop.
weight
kg/km
200,0
297,0
504,0
796,0
1142,0
1526,0
2203,0
3082,0
4208,0
5388,0
6558,0
8159,0
10546,0
133,0
499,0

Weight
approx.
kg/km
420,0
540,0
800,0
1150,0
1670,0
2160,0
2860,0
3980,0
5300,0
6740,0
8210,0
10200,0
12900,0
360,0
1070,0

AWG-No.
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
16
16

Dimensions and specifications may be changed without prior notice. (RQ02)

Drag Chain Systems


Open chains
Closed chains
Accessories
Installation instructions
Selection tables

You can nd drag chain systems in our catalogue Cable Accessories.

Q 34
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NHXH-FE 180/E 30 security cable, halogen-free, 0,6/1kV, with improved


fire characteristics


Technical data

Cable structure

Properties

Halogen-free security cable with improved


characteristics in the case of fire to
DINVDE0266
Insulation integrity
180 minutes to DINVDE0472 part814
Functionality
30 minutes to DINVDE4102 part12
Temperature range
-30 C to +70 C
Permissible operating temperature
at conductor +90 C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4000 V
Minimum bending radius
approx. 15xcable
Radiation resistance
up to 200x106 cJ/kg (up to 200 Mrad)
Caloric load values
see Technical Informations

Bare copper conductor, solid or stranded,


to DINVDE0295 cl.1 or cl.2
Double core insulation of mica tape and
cross-linked polymer HI1, to DINVDE0207
part23
Colour coding of cores according to
DINVDE0293-308
Green-yellow earth-core, 3 cores and above
Cores stranded in layer
Core wrapping with glass-fibre tape as
flame-protection
Outer jacket orange, polymer-compound
DINVDE0207 part24,
flame retardant
Tests
Flame test to VDE0482-332-3, BS4066
part3/ DINEN60332-3/ IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Halogen-free according to VDE0482
part267/ DINEN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
(equivalent DINVDE0472 part816)
Insulation integrity under flame
propagation to VDE0472 part814
IEC60331
Burning behaviour in fire(functionality) of
the complete cable system to DIN4102
part12 (30minutes)
LS0H = Low Smoke Zero Halogen-free.


Halogen-free; no evolution of corrosive


and toxic gases
Flame retardant
Hardly flammable
Self-extinguished and fire resistant
No flame propagation, therefore security
from fire
Low smoke density, no darkening of
emergency exits without hindering the fire
extinguishing works
Toxicological harmless
No self-ignition
Maintenance of functionality during the
increased current load
FE180: Insulation integrity for
180minutes. Tests to DINVDE0472
part814 IEC60331.
Insulation integrity under direct flame
propagation for the test period of
180minutes.
E30: Functionality of electrical cable
systems for minimum 30minutes. Test to
DIN4102 part12. This fulfils the demands
of technical guide lines for fire protection
(supplement 1 to DINVDE0108 part1).
The functionality for 30minutes assures
when persons and animals are to be saved
from a burning building. 30minutes
secures the functional performance of the
fire warning and alarm systems, safety and
spare lighting, passenger lifts with
evacuation circuits, except the cables which
are installed within the ladder shafts and
engine rooms.


Note

rm = round conductor, multiple-wire;


re = round conductor, single-wire.

Application
Security cables are ideal for use everywhere, where in case of fire human life and material assets are to be protected and safety conciousness
take a special significance, e.g. in industrial complexes, power stations, communal establishment, hotels, airports, underground railway
networks, hospitals and outpatients clinic (DINVDE0107), department stores, data processing centres, theaters, cinemas, in multi-storey
buildings, public gatherings, schools etc. (DINVDE0108), mining works, offshore plants, leading centres, traffic communication, emergency
power supply and alarm systems. The cables are suitable for fixed installation in dry and moist rooms, in, above, on and beneath plaster as
well as in masonary walls and in concrete. These cables are suitable for outdoor applications and in underground by using in conduits or
tubes. Additionally valid also DINVDE0298 part1 and 2.
For the installation in conduit all precautions must be taken that no accumulation of water can occur in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
52700
52701
52702
52703
52704
52705
52706

No.cores x
cross-sec.
mm
1x4  re
1x6  re
1x10  re
1x16  rm
1x25  rm
1x35  rm
1x50  rm

Outer
approx.
mm
7,0
7,5
8,0
9,0
10,5
11,5
12,0

Cop.
weight
kg/km
38,0
58,0
96,0
154,0
240,0
336,0
480,0

Weight
approx.
kg/km
98,0
125,0
165,0
230,0
345,0
450,0
590,0

AWG-No.
12
10
8
6
4
2
1


Part no.
52707
52708
52709
52710
52711
52712
52713
52714

No.cores x
cross-sec.
mm
1x70  rm
1x95  rm
1x120  rm
1x150  rm
1x185  rm
1x240  rm
1x300  rm
2x2,5  re

Outer
approx.
mm
15,0
16,5
18,5
20,5
23,0
25,5
31,8
12,5

Cop.
weight
kg/km
672,0
912,0
1152,0
1440,0
1776,0
2304,0
2880,0
48,0

Weight
approx.
kg/km
800,0
1100,0
1350,0
1650,0
2000,0
2650,0
3200,0
290,0

AWG-No.
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
14

Continuation

Q 35
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NHXH-FE 180/E 30 security cable, halogen-free, 0,6/1kV, with improved


fire characteristics

Part no.
52715
52716
52717
52718
52719
52720
52721
52722
52723
52724
52725
52726
52727
52728
52729
52730
52731
52732
52733
52734
52735
52736
52737
52738
52739
52740
52741
52742
52743
52744
52745
52746
52747
52748

No.cores x
cross-sec.
mm
2x4  re
2x6  re
2x10  re
2x16  rm
2x25  rm
2x35  rm
3x1,5  re
3x2,5  re
3x4  re
3x6  re
3x10  re
3x16  rm
3x25  rm
3x35  rm
3x50  rm
3x70  rm
3x95  rm
3x120  rm
3x150  rm
3x185  rm
3x240  rm
4x1,5  re
4x2,5  re
4x4  re
4x6  re
4x10  re
4x16  rm
4x25  rm
4x35  rm
4x50  rm
4x70  rm
4x95  rm
4x120  rm
4x150  rm

Outer
approx.
mm
13,5
14,5
16,0
18,0
21,0
24,0
12,5
13,5
14,5
15,5
17,0
19,0
22,5
24,5
27,5
32,0
35,5
39,5
44,0
49,5
60,0
13,5
14,0
15,5
16,5
18,5
20,5
24,5
27,0
30,0
35,0
39,5
43,5
49,0

Cop.
weight
kg/km
77,0
115,0
192,0
307,0
480,0
672,0
43,0
72,0
115,0
173,0
288,0
461,0
720,0
1080,0
1440,0
2016,0
2736,0
3456,0
4320,0
5328,0
6910,0
58,0
96,0
154,0
230,0
384,0
614,0
960,0
1344,0
1920,0
2688,0
3648,0
4608,0
5760,0

Weight
approx.
kg/km
345,0
410,0
540,0
720,0
1100,0
1120,0
280,0
330,0
400,0
480,0
650,0
850,0
1300,0
1700,0
2200,0
3000,0
4000,0
4850,0
5950,0
7450,0
8600,0
325,0
385,0
470,0
580,0
790,0
1100,0
1650,0
2150,0
2800,0
3800,0
5050,0
6150,0
7650,0

AWG-No.
12
10
8
6
4
2
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil


Part no.
52749
52750
52751
52752
52753
52754
52755
52756
52757
52758
52759
52760
52761
52762
52763
52764
52765
52766
52767
52768
52769
52770

No.cores x
cross-sec.
mm
5x1,5  re
5x2,5  re
5x4  re
5x6  re
5x10  re
5x16  rm
5x25  rm
5x35  rm
7x1,5  re
7x2,5  re
10x1,5  re
10x2,5  re
12x1,5  re
12x2,5  re
14x1,5  re
14x2,5  re
19x1,5  re
19x2,5  re
24x1,5  re
24x2,5  re
30x1,5  re
30x2,5  re

Outer
approx.
mm
14,0
15,0
16,5
18,0
20,0
22,5
26,5
36,0
15,0
16,5
18,0
20,0
19,0
20,5
20,0
21,5
21,5
23,5
25,0
27,0
26,0
28,5

Cop.
weight
kg/km
72,0
120,0
192,0
288,0
480,0
768,0
1200,0
1680,0
101,0
168,0
144,0
240,0
173,0
288,0
202,0
336,0
274,0
456,0
346,0
576,0
432,0
720,0

Weight
approx.
kg/km
375,0
445,0
560,0
690,0
950,0
1300,0
1980,0
2600,0
365,0
540,0
580,0
710,0
640,0
790,0
740,0
880,0
880,0
1150,0
1100,0
1400,0
1300,0
1650,0

AWG-No.
16
14
12
10
8
6
4
2
16
14
16
14
16
14
16
14
16
14
16
14
16
14

Dimensions and specifications may be changed without prior notice. (RQ02)

Q 36
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NHXCH-FE 180/E 30 security cable, halogen-free, 0,6/1kV,


with improved fire characteristics


Technical data

Cable structure

Properties

Halogen-free security cable with improved


characteristics in the case of fire to
DINVDE0266
Insulation integrity
180 minutes to DINVDE0472 part814
Functionality
30 minutes to DINVDE4102 part12
Permissible operating temperature
at conductor +90 C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4000 V
Minimum bending radius
approx. 15xcable
Radiation resistance
up to 200x106 cJ/kg (up to 200 Mrad)
Caloric load values
see Technical Informations

Bare copper conductor, solid or stranded,


to DINVDE0295 cl.1 or cl.2, BS6360 cl.1
or 2, IEC60228 cl.1 or cl.2, HD383
Special core insulation of mica tape and
cross-linked polymer HI1 to DINVDE0207
part23
Colour coding of cores according to
DINVDE0293-308
Core stranded in layer
Core wrapping with glass-fibre tape
Copper wire screening with helix of copper
tape
Separator of special tape
Outer jacket orange, polymer-compound
HM4, to DINVDE0207 part24, flame
retardant
Tests
Flame test to VDE0482 part266-2, BS4066
part3/ DINEN50266-2/ IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Halogen-free according to VDE0482
part267/ DINEN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
(equivalent DINVDE0472 part816)
Insulation integrity under flame
propagation to VDE0472
part814IEC60331
Burning behaviour in fire (functionality) of
the complete cable system to DIN4102
part12 (30minutes)
LS0H = Low Smoke Zero Halogen-free.


Halogen-free; no evolution of corrosive


and toxic gases
Flame retardant and hardly flammable
Self-extinguished and fire resistant
No flame propagation, therefore security
from fire
Low smoke density, no darkening
Toxicological harmless
No self-ignition
Maintenance of functionality during the
increased current load
FE180: Insulation integrity for
180minutes. Tests to DINVDE0472
part814IEC60331.
Insulation integrity under direct flame
propagation for the test period of
180minutes.
E30: Functionality of electrical cable
systems for minimum 30minutes. Test
method to DIN4102 part12. This fulfils the
demands of technical guide lines for fire
protection (supplement1 to DINVDE0108
part1).
The functionality for 30 minutes assures
when persons and animals are to be saved
from a burning building. 30minutes
secures the functional performance of the
fire warning and alarm systems, safety and
spare lighting, passenger lifts with
evacuation circuits, except the cables which
are installed within the ladder shafts and
engine rooms.


Note

re = round solid core;


rm = stranded core.

Application
Everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a special significance,
e.g. in industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals and
outpatients clinic (DINVDE0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings,
schools etc. (DINVDE0108), mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm
systems. Suitable for fixed installation in dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete.
These cables are suitable for outdoor applications and in underground by using in conduits or tubes. Additionally valid also DINVDE0298
part1 and 2. For the installation in conduit all precautions must be taken that no accumulation of water can occur in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
52900
52901
52902
52903
52904
52905
52906

No.cores x
cross-sec.
mm
2x1,5 / 1,5  re
2x2,5 / 2,5  re
2x4 / 4  re
2x6 / 6  re
2x10 / 10  re
3x1,5 / 1,5  re
3x2,5 / 2,5  re

Outer
approx.
mm
15,0
13,5
14,5
16,0
18,0
13,5
14,5

Cop.
weight
kg/km
52,0
80,0
123,0
182,0
312,0
66,0
104,0

Weight
approx.
kg/km
220,0
385,0
470,0
550,0
730,0
380,0
430,0

AWG-No.
16
14
10
10
8
16
14


Part no.
52907
52908
52909
52910
52911
52912
52913

No.cores x
cross-sec.
mm
3x4 / 4  re
3x6 / 6  re
3x10 / 10  re
3x16 / 16  rm
3x25 / 16  rm
3x35 / 16  rm
3x50 / 25  rm

Outer
approx.
mm
15,5
16,5
18,5
20,5
24,0
26,5
29,5

Cop.
weight
kg/km
161,0
240,0
408,0
643,0
902,0
1190,0
1723,0

Weight
approx.
kg/km
530,0
630,0
850,0
1150,0
1700,0
2150,0
2800,0

AWG-No.
12
10
8
6
4
2
1

Continuation

Q 37
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NHXCH-FE 180/E 30 security cable, halogen-free, 0,6/1kV,


with improved fire characteristics

Part no.
52914
52915
52916
52917
52918
52919
52920
52921
52922
52923
52924
52925
52926
52927
52928
52929

No.cores x
cross-sec.
mm
3x70 / 35  rm
3x95 / 50  rm
3x120 / 70  rm
3x150 / 70  rm
3x185 / 95  rm
3x240 / 120  rm
4x1,5 / 1,5  re
4x2,5 / 2,5  re
4x4 / 4  re
4x6 / 6  re
4x10 / 10  re
4x16 / 16  re
4x25 / 16  rm
4x35 / 16  rm
4x50 / 25  rm
4x70 / 35  rm

Outer
approx.
mm
33,0
37,5
42,5
47,0
52,5
58,5
14,5
15,5
16,5
17,5
20,0
22,0
26,0
28,5
32,0
37,0

Cop.
weight
kg/km
2410,0
3296,0
4236,0
5100,0
6383,0
8242,0
81,0
128,0
200,0
297,0
504,0
796,0
1142,0
1526,0
2203,0
3082,0

Weight
approx.
kg/km
3800,0
5100,0
6250,0
6900,0
8550,0
11150,0
435,0
500,0
610,0
740,0
1050,0
1350,0
1950,0
2400,0
3200,0
4300,0

AWG-No.
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
16
14
12
10
8
6
4
2
1
2/0


Part no.
52930
52931
52932
52933
52934
52935
52936
52937
52938
52939
52940
52941
52942
52943
52944

No.cores x
cross-sec.
mm
4x95 / 50  rm
4x120 / 70  rm
4x150 / 70  rm
4x185 / 95  rm
4x240 / 120  rm
7x1,5 / 2,5  re
7x2,5 / 2,5  re
10x1,5 / 2,5  re
10x2,5 / 4  re
12x1,5 / 2,5  re
12x2,5 / 4  re
24x1,5 / 6  re
24x2,5 / 10  re
30x1,5 / 6  re
30x2,5 / 10  re

Outer
approx.
mm
41,5
47,0
52,0
58,0
64,0
16,5
17,5
19,5
21,0
20,0
21,5
26,0
28,5
27,0
30,0

Cop.
weight
kg/km
4208,0
5388,0
6558,0
8159,0
10546,0
133,0
200,0
176,0
286,0
205,0
334,0
413,0
696,0
499,0
840,0

Weight
approx.
kg/km
5750,0
7100,0
8550,0
10700,0
13930,0
635,0
680,0
870,0
980,0
1050,0
1050,0
1900,0
1900,0
2200,0
2200,0

AWG-No.
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
16
14
16
14
16
14
16
14
16
14

Dimensions and specifications may be changed without prior notice. (RQ02)

Insulating, shrinking, braided and


temperature protection tubes
Braided hoses
High temperature protection
Insulation tubes
Heat-shrink tubes
End caps

You can nd insulating, shrinking, braided and temperature protection tubes


in our catalogue Cable Accessories.

Q 38
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XH-FE 180/E 90 security cable, halogen-free, 0,6/1kV,


with improved fire characteristics


Technical data

Cable structure

Properties

Halogen-free security cable with improved


characteristics in the case of fire to
DINVDE0266
Insulation integrity
180 minutes to DINVDE0472 part814
Functionality
90 minutes to DINVDE4102 part12
Temperature range
-30 C to +70 C
Permissible operating temperature
at conductor +90 C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4000 V
Minimum bending radius
approx. 12x cable
Radiation resistance
up to 200x106 cJ/kg (up to 200 Mrad)
Caloric load values
see Technical Informations


Bare copper conductor, solid or stranded,


to DINVDE0295 cl.1 or cl.2, BS6360 cl.1
or 2, IEC60228 cl.1 or cl.2, HD383
Core with double insulation: Flame
retardant MICA-tapeover conductor
Core insulation with cross-linked
polyethylene, compound type 2XI1 to
DINVDE0276 part604
Cores colour coding to DINVDE0293-308
and 0276 part604
Green-yellow earth-core, 3 cores and above
Cores stranded in layers
Overall core covering, halogen-free filling
compound, pressed
Outer jacket of thermoplastic halogen-free
polyolefine, compound type HM4 to
DINVDE0276 part 604, flame retardant,
colour orange
Tests
Flame test to VDE 0482 part 266-2, BS 4066
part 3/ DIN EN 50266-2/ IEC 60332-3
(equivalent DIN VDE 0472 part 804 test
method C)
Corrosiveness of combustion gases
according to VDE 0482 part 267/ DIN EN
50267-2-2/ IEC 60754-2 (equivalent DIN VDE
0472 part 813)
Halogen-free according to VDE 0482 part
267/ DIN EN 50267-2-1/ IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density according to VDE 0482 part
1034-1+2/ IEC 61034-1+2/ DIN EN
61034-1+2/ BS 7622 part 1+2 (equivalent
DIN VDE 0472 part 816)
Insulation integrity under flame
propagation to VDE 0472 part 814 IEC
60331
Functionality of the complete cable
system to DIN4102 part 12 (90 minutes)
LS0H = Low Smoke Zero Halogen-free.

Halogen-free; no evolution of corrosive


and toxic gases
Flame retardant
Hardly flammable
Self-extinguished and fire resistant
No flame propagation, therefore security
from fire
Low smoke density, no darkening of
emergency exits without hindering the fire
extinguishing works
Toxicological harmless
No self-ignition
Maintenance of functionality during the
increased current load
FE180: Insulation integrity for
180minutes. Tests to DINVDE0472
part814 IEC60331.
Insulation integrity under direct flame
propagation for the test period of
180minutes.
E90: Functionality of electrical cable
systems for minimum 90minutes. Test
method to DIN4102 part12. This fulfils the
demands of technical guide lines for fire
protection (supplement1 to DINVDE0108
part1).
The functionality for 90minutes assures
the functional performance of
water-pressure-rising stations for the
supply to avoid smoke and heat in
safety-stairs and inner rooms, ladder shafts
and engine rooms for fire brigade lifts,
emergency lifts for sickbeds in hospitals
and the fire brigade lifts.


Note

rm = round conductor, multiple-wire;


re = round conductor, single-wire.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a special significance,
e.g. in industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals and
outpatients clinic (DINVDE0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings,
schools etc. (DINVDE0108), mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm
systems. Suitable for fixed installation in dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete.
These cables are suitable for outdoor applications and in underground by using in conduits or tubes.
Additionally valid also DINVDE0298 part1 and 2.
For the installation in conduit all precautions must be taken that no accumulation of water can occur in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
52534
52535
52536
52537

No.cores x
cross-sec.
mm
1x16  rm
1x25  rm
1x35  rm
1x50  rm

Outer
approx.
mm
11,5
13,0
14,0
15,5

Cop.
weight
kg/km
154,0
240,0
336,0
480,0

Weight
approx.
kg/km
250,0
360,0
460,0
610,0

AWG-No.
6
4
2
1


Part no.
52538
52539
52540
52541

No.cores x
cross-sec.
mm
1x70  rm
1x95  rm
1x120  rm
1x150  rm

Outer
approx.
mm
17,5
19,5
21,5
23,5

Cop.
weight
kg/km
672,0
912,0
1152,0
1440,0

Weight
approx.
kg/km
840,0
1120,0
1390,0
1690,0

AWG-No.
2/0
3/0
4/0
300 kcmil

Continuation

Q 39
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XH-FE 180/E 90 security cable, halogen-free, 0,6/1kV,


with improved fire characteristics




Part no.
52542
52899
52543
52544
52545
52546
52547
52548
52549
52550
52551
52552
52553
52554
52555
52556
52557
52558
52559
52560
52561
52562
52563
52572
52564
52565
52573
52566
52574
52567
52575
52576
52568
52577
52569
52578
52570
52579
52571
52580
52581
52582

No.cores x
cross-sec.
mm
1x185  rm
1x240  rm
1x300  rm
1x400  rm
2x1,5  re
2x2,5  re
2x4  re
2x6  re
2x10  rm
2x16  rm
2x25  rm
2x35  rm
2x50  rm
2x70  rm
2x95  rm
2x120  rm
3x1,5  re
3x2,5  re
3x4  re
3x6  re
3x10  rm
3x16  rm
3x25  rm
3x35 / 16  rm
3x35  rm
3x50  rm
3x50 / 25  rm
3x70  rm
3x70 / 35  rm
3x95  rm
3x95 / 50  rm
3x120 / 70  rm
3x120  rm
3x150 / 70  rm
3x150  rm
3x185 / 95  rm
3x185  rm
3x240 / 120  rm
3x240  rm
4x1,5  re
4x2,5  re
4x4  re

Outer
approx.
mm
25,5
28,5
31,0
34,5
14,5
15,5
16,5
17,5
19,5
21,0
23,5
26,5
30,0
33,0
37,5
41,0
15,0
16,0
17,0
18,0
20,5
22,5
26,0
29,5
28,0
32,0
33,5
35,5
37,0
40,5
42,0
46,5
44,0
50,0
48,5
55,5
53,0
61,5
59,5
16,5
17,5
18,5

Cop.
weight
kg/km
1776,0
2304,0
2880,0
3840,0
29,0
48,0
77,0
115,0
192,0
307,0
480,0
672,0
960,0
1344,0
1824,0
2304,0
43,0
72,0
115,0
173,0
288,0
461,0
720,0
1162,0
1008,0
1440,0
1680,0
2016,0
2352,0
2736,0
3216,0
4128,0
3456,0
4992,0
4320,0
6240,0
5328,0
8064,0
6912,0
58,0
96,0
154,0

Weight
approx.
kg/km
2090,0
2660,0
3350,0
4230,0
270,0
310,0
370,0
440,0
600,0
780,0
1100,0
1400,0
1830,0
2420,0
3240,0
3940,0
260,0
350,0
420,0
520,0
710,0
950,0
1370,0
1950,0
1750,0
2310,0
2640,0
3100,0
3520,0
4180,0
4710,0
5910,0
5130,0
6970,0
6260,0
8750,0
7720,0
11180,0
9990,0
350,0
420,0
510,0

AWG-No.
350 kcmil
500 kcmil
600 kcmil
750 kcmil
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
16
14
12
10
8
6
4
2
2
1
1
2/0
2/0
3/0
3/0
4/0
4/0
300 kcmil
300 kcmil
350 kcmil
350 kcmil
500 kcmil
500 kcmil
16
14
12


Part no.
52583
52584
52585
52586
52587
52588
52589
52590
52591
52592
52593
52594
52595
52596
52597
52598
52599
52600
52601
52602
52603
52604
52605
52606
52607
52608
52609
52610
52611
52612

No.cores x
cross-sec.
mm
4x6  re
4x10  rm
4x16  rm
4x25  rm
4x35  rm
4x50  rm
4x70  rm
4x95  rm
4x120  rm
4x150  rm
4x185  rm
4x240  rm
5x1,5  re
5x2,5  re
5x4  re
5x6  re
5x10  rm
5x16  rm
5x25  rm
5x35  rm
5x50  rm
5x70  rm
7x1,5  re
7x2,5  re
7x4  re
10x1,5  re
10x2,5  re
12x1,5  re
12x2,5  re
24x1,5  re

Outer
approx.
mm
19,5
22,5
24,5
28,5
31,0
35,0
39,0
45,0
48,5
54,0
59,0
66,0
18,0
19,0
20,0
21,5
24,5
27,0
31,0
34,0
38,5
43,5
19,5
20,5
22,0
24,0
25,5
24,5
26,0
33,0

Cop.
weight
kg/km
230,0
384,0
614,0
960,0
1344,0
1920,0
2688,0
3648,0
4608,0
5760,0
7104,0
9216,0
72,0
120,0
192,0
288,0
480,0
768,0
1200,0
1680,0
2400,0
3360,0
101,0
168,0
269,0
144,0
240,0
173,0
288,0
346,0

Weight
approx.
kg/km
630,0
880,0
1180,0
1730,0
2220,0
2940,0
3960,0
5360,0
6550,0
8070,0
9970,0
12830,0
420,0
500,0
610,0
760,0
1070,0
1450,0
2120,0
2730,0
3620,0
4940,0
480,0
580,0
730,0
650,0
790,0
720,0
890,0
1270,0

AWG-No.
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
16
14
12
10
8
6
4
2
1
2/0
16
14
12
16
14
16
14
16

Dimensions and specifications may be changed without prior notice. (RQ02)

Q 40
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XCH-FE 180/E 90 security cable, halogen-free, 0,6/1kV,


with improved fire characteristics


Technical data

Cable structure

Properties

Halogen-free security cable with improved


characteristics in the case of fire to
DINVDE0266
Insulation integrity
180 minutes to DINVDE0472 part814
Functionality
90 minutes to DINVDE4102 part12
Temperature range
-30 C to +70 C
Permissible operating temperature
at conductor +90 C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4000 V
Minimum bending radius
approx. 12x cable
Radiation resistance
up to 200x106 cJ/kg (up to 200 Mrad)
Caloric load values
see Technical Informations

Bare copper conductor, solid or stranded,


to DINVDE0295 cl.1 and cl.2, BS6360 cl.1
or 2, IEC60228 cl.1 or 2, HD383
Core with double insulation:
Flame retardant MICA-tapeover conductor
Core insulation with cross-linked
polyethylene, compound type 2XI1 to
DINVDE0276 part604
Cores colour coding to DINVDE0293-308
and 0276 part604
Cores stranded in layers
Overall core covering, halogen-free filling
compound, pressed
Concentric conductor of Cu-bare wires with
helix of copper tape
Outer jacket of thermoplastic halogen-free
polyolefine, compound type HM4 to
DINVDE0276 part604, flame retardant
Colour orange
Tests
Flame test to VDE 0482 part 266-2, BS 4066
part 3/ DIN EN 50266-2/ IEC 60332-3
(equivalent DIN VDE 0472 part 804 test
method C)
Corrosiveness of combustion gases
according to VDE 0482 part 267/ DIN EN
50267-2-2/ IEC 60754-2 (equivalent DIN VDE
0472 part 813)
Halogen-free according to VDE 0482 part
267/ DIN EN 50267-2-1/ IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density according to VDE 0482 part
1034-1+2/ IEC 61034-1+2/ DIN EN
61034-1+2/ BS 7622 part 1+2 (equivalent
DIN VDE 0472 part 816)
Insulation integrity under flame
propagation to VDE 0472 part 814 IEC
60331
Functionality of the complete cable
system to DIN4102 part 12 (90 minutes)

Halogen-free; no evolution of corrosive


and toxic gases
Flame retardant
Hardly flammable
Self-extinguished and fire resistant
No flame propagation, therefore security
from fire
Low smoke density, no darkening of
emergency exits without hindering the fire
extinguishing works
Toxicological harmless
No self-ignition
Maintenance of functionallity during the
increased current load
FE180: Insulation integrity for
180minutes. Tests to DINVDE0472
part814 IEC60331.
Insulation integrity under direct flame
propagation for the test period of
 180minutes.
E90: Functionality of electrical cable
systems for minimum 90minutes. Test
method to DIN4102 part12. This fulfils the
demands of technical guide lines for fire
protection (supplement1 to DINVDE0108
part1).
The functionality for 90minutes assures
the functional performance of
water-pressure-rising stations for the
supply to avoid smoke and heat in
safety-stairs and inner rooms, ladder shafts
and engine rooms for fire brigade lifts,
emergency lifts for sickbeds in hospitals
and the fire brigade lifts.


Note

re = round solid core;


rm = stranded core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a special significance,
e.g. in industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals and
outpatients clinic (DINVDE0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings,
schools etc. (DINVDE0108), mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm
systems. Suitable for fixed installation in dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete.
These cables are suitable for outdoor applications and in underground by using in conduits or tubes. Additionally valid also DINVDE0298
part1 and 2. For the installation in conduit all precautions must be taken that no accumulation of water can occur in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
52771
52772
52773
52774
52775

No.cores x
cross-sec.
mm
3x1,5 / 1,5  re
3x2,5 / 2,5  re
3x4 / 4  re
3x6 / 6  re
3x10 / 10  rm

Outer
approx.
mm
16,5
17,5
18,5
20,0
22,0

Cop.
weight
kg/km
66,0
104,0
161,0
240,0
408,0

Weight
approx.
kg/km
330,0
400,0
480,0
600,0
840,0

AWG-No.
16
14
12
10
8


Part no.
52776
52777
52778
52779
52780

No.cores x
cross-sec.
mm
3x16 / 16  rm
3x25 / 16  rm
3x35 / 16  rm
3x50 / 25  rm
3x70 / 35  rm

Outer
approx.
mm
24,5
28,0
30,5
34,0
37,5

Cop.
weight
kg/km
643,0
902,0
1190,0
1723,0
2410,0

Weight
approx.
kg/km
1130,0
1560,0
1960,0
2610,0
3500,0

AWG-No.
6
4
2
1
2/0

Continuation

Q 41
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XCH-FE 180/E 90 security cable, halogen-free, 0,6/1kV,


with improved fire characteristics




Part no.
52781
52782
52783
52784
52785
52786
52787
52788
52789
52790
52791
52792
52793
52794

No.cores x
cross-sec.
mm
3x95 / 50  rm
3x120 / 70  rm
3x150 / 70  rm
3x185 / 95  rm
3x240 / 120  rm
4x1,5 / 1,5  re
4x2,5 / 2,5  re
4x4 / 4  re
4x6 / 6  re
4x10 / 10  rm
4x16 / 16  rm
4x25 / 16  rm
4x35 / 16  rm
4x50 / 25  rm

Outer
approx.
mm
43,0
48,0
52,0
57,5
63,5
17,5
19,0
20,0
21,5
24,0
26,5
30,5
33,0
37,5

Cop.
weight
kg/km
3296,0
4236,0
4992,0
6383,0
8242,0
81,0
128,0
200,0
297,0
504,0
796,0
1142,0
1526,0
2203,0

Weight
approx.
kg/km
4700,0
5880,0
7300,0
8760,0
11280,0
390,0
470,0
570,0
720,0
1010,0
1370,0
1940,0
2420,0
3240,0

AWG-No.
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
16
14
12
10
8
6
4
2
1


Part no.
52795
52796
52797
52798
52799
52800
52801
52805
52802
52806
52803
52807
52804
52808

No.cores x
cross-sec.
mm
4x70 / 35  rm
4x95 / 50  rm
4x120 / 70  rm
4x150 / 70  rm
4x185 / 95  rm
4x240 / 120  rm
7x1,5 / 2,5  re
7x2,5 / 2,5  re
12x1,5 / 2,5  re
12x2,5 / 4  re
24x1,5 / 6  re
24x2,5 / 10  re
30x1,5 / 6  re
30x2,5 / 10  re

Outer
approx.
mm
41,5
47,5
52,5
57,5
63,5
70,0
20,5
22,0
26,0
28,0
35,0
37,5
37,0
39,5

Cop.
weight
kg/km
3082,0
4208,0
5388,0
6540,0
8159,0
10546,0
133,0
200,0
205,0
334,0
413,0
696,0
499,0
840,0

Weight
approx.
kg/km
4360,0
5900,0
7340,0
8840,0
11020,0
14140,0
520,0
630,0
770,0
950,0
1380,0
1750,0
1630,0
2080,0

AWG-No.
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
16
14
16
14
16
14
16
14

Dimensions and specifications may be changed without prior notice. (RQ02)

Terminations and straight-through joints


Telephone calbes
Low voltage
Medium voltage
Accessories

You can nd terminations and straight-through joints in our catalogue Cable Accessories.

Q 42
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NHXH-FE 180/E 90 security cable, halogen-free, 0,6/1kV,


with improved fire characteristics


Technical data

Cable structure

Properties

Halogen-free security cable with improved


characteristics in the case of fire to
DINVDE0266
Insulation integrity
180 minutes to DINVDE0472 part814
Functionality
90 minutes to DINVDE4102 part12
Temperature range
-30 C to +70 C
Permissible operating temperature
at conductor +90 C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4000 V
Minimum bending radius
approx. 12x cable
Radiation resistance
up to 200x106 cJ/kg (up to 200 Mrad)
Caloric load values
see Technical Informations

Bare copper conductor, solid or stranded,


to DINVDE0295 cl.1 or cl.2, BS6360 cl.1
or 2, IEC60228 cl.1 or cl.2, HD383
Double core insulation of mica tape and
cross-linked polymer HI1, to DINVDE0207
part23
Colour coding of cores according to
DINVDE0293-308
Each single core covering with flame
resistant glass-fibre tape
Cores stranded in layer
Core wrapping with glass-fibre tape as
flame-protection
Outer jacket orange, polyolefin compound
HM4, to DINVDE0207 part24 HM4
Tests
Flame test to VDE 0482 part 266-2, BS 4066
part 3/ DIN EN 50266-2/ IEC 60332-3
(equivalent DIN VDE 0472 part 804 test
method C)
Corrosiveness of combustion gases
according to VDE 0482 part 267/ DIN EN
50267-2-2/ IEC 60754-2 (equivalent DIN VDE
0472 part 813)
Halogen-free according to VDE 0482 part
267/ DIN EN 50267-2-1/ IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density according to VDE 0482 part
1034-1+2/ IEC 61034-1+2/ DIN EN
61034-1+2/ BS 7622 part 1+2 (equivalent
DIN VDE 0472 part 816)
Insulation integrity under flame
propagation to VDE 0472 part 814 IEC
60331
Functionality of the complete cable
system to DIN4102 part 12 (90 minutes)

Halogen-free; no evolution of corrosive


and toxic gases
Flame retardant
Hardly flammable
Self-extinguished and fire resistant
No flame propagation, therefore security
from fire
Low smoke density, no darkening of
emergency exits without hindering the fire
extinguishing works
Toxicological harmless
No self-ignition
Maintenance of functionallity during the
increased current load
FE180: Insulation integrity for
180minutes. Tests to DINVDE0472
part814 IEC60331.
Insulation integrity under direct flame
propagation for the test period of
180minutes.
E90: Functionality of electrical cable
systems for minimum 90minutes. Test
method to DIN4102 part12. This fulfils the
demands of technical guide lines for fire
protection (supplement 1 to DINVDE0108
part1).
The functionality for 90minutes assures
the functional performance of
water-pressure-rising stations for the
supply to avoid smoke and heat in
safety-stairs and inner rooms, ladder shafts
and engine rooms for fire brigade lifts,
emergency lifts for sickbeds in hospitals
and the fire brigade lifts.


Note

re = round solid core;


rm = stranded core.


Application
Everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a special significance,
e.g. in industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals and
outpatients clinic (DINVDE0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings,
schools etc. (DINVDE0108), mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm
systems. Suitable for fixed installation in dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete.
These cables are suitable for outdoor applications and in underground by using in conduits or tubes. Additionally valid also DINVDE0298
part1 and 2. For the installation in conduit all precautions must be taken that no accumulation of water can occur in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
53180
53181
53182
53183
53184
53185
53186
53187

No.cores x
cross-sec.
mm
1x16  rm
1x25  rm
1x35  rm
1x50  rm
1x70  rm
1x95  rm
1x120  rm
1x150  rm

Outer
approx.
mm
11,0
12,5
13,5
15,0
16,5
18,0
20,5
22,5

Cop.
weight
kg/km
154,0
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0

Weight
approx.
kg/km
255,0
375,0
475,0
625,0
855,0
1140,0
1410,0
1730,0

AWG-No.
6
4
2
1
2/0
3/0
4/0
300 kcmil


Part no.
53188
53189
53190
53191
53000
53001
53002
53003

No.cores x
cross-sec.
mm
1x185  rm
1x240  rm
1x300  rm
1x400  rm
3x1,5  re
3x2,5  re
3x4  re
3x6  re

Outer
approx.
mm
24,5
27,0
30,0
33,5
14,0
15,0
16,0
17,0

Cop.
weight
kg/km
1776,0
2304,0
2880,0
3840,0
43,0
72,0
115,0
173,0

Weight
approx.
kg/km
2140,0
2700,0
3420,0
4310,0
280,0
330,0
400,0
480,0

AWG-No.
350 kcmil
500 kcmil
600 kcmil
750 kcmil
16
14
12
10

Continuation

Q 43
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NHXH-FE 180/E 90 security cable, halogen-free, 0,6/1kV,


with improved fire characteristics




Part no.
53004
53005
52990
52992
52991
52993
52994
52995
52996
52997
52998
52999
53006
53007
53008
53009
53010
53011
53012
53013
53014
53030
53031

No.cores x
cross-sec.
mm
3x10  re
3x16  re
3x25  rm
3x35 / 16  rm
3x35  rm
3x50 / 25  rm
3x70 / 35  rm
3x95 / 50  rm
3x120 / 70  rm
3x150 / 70  rm
3x185 / 95  rm
3x240 / 120  rm
4x1,5  re
4x2,5  re
4x4  re
4x6  re
4x10  re
4x16  re
4x25  rm
4x35  rm
4x50  rm
4x70  rm
4x95  rm

Outer
approx.
mm
19,0
21,0
25,0
28,0
28,0
32,0
36,0
42,0
45,0
49,0
55,0
63,0
15,0
16,0
17,0
18,0
20,0
22,0
27,0
30,0
34,0
39,0
44,0

Cop.
weight
kg/km
288,0
461,0
720,0
1162,0
1008,0
1680,0
2352,0
3216,0
4128,0
4992,0
6240,0
8064,0
58,0
96,0
154,0
230,0
384,0
614,0
960,0
1344,0
1920,0
2688,0
3648,0

Weight
approx.
kg/km
650,0
850,0
1300,0
1850,0
1700,0
2500,0
3350,0
4500,0
5600,0
6700,0
8350,0
10000,0
325,0
385,0
470,0
580,0
790,0
1100,0
1650,0
2150,0
2800,0
3800,0
5050,0

AWG-No.
8
6
4
2
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
16
14
12
10
8
6
4
2
1
2/0
3/0


Part no.
53070
53390
53015
53016
53017
53018
53019
53020
53021
53028
53029
53022
53027
53025
53026
53023
53024

No.cores x
cross-sec.
mm
4x120  rm
4x150  rm
5x1,5  re
5x2,5  re
5x4  re
5x6  re
5x10  re
5x16  rm
5x25  rm
5x35  rm
5x50  rm
7x1,5  re
7x2,5  re
10x1,5  re
10x2,5  re
12x1,5  re
12x2,5  re

Outer
approx.
mm
47,0
51,2
16,0
17,0
18,0
20,0
22,0
24,0
29,0
33,0
38,0
19,0
21,0
23,0
25,0
25,0
26,0

Cop.
weight
kg/km
4608,0
5760,0
72,0
120,0
192,0
288,0
480,0
768,0
1200,0
1680,0
2500,0
101,0
168,0
144,0
240,0
173,0
288,0

Weight
approx.
kg/km
6150,0
7662,0
375,0
445,0
560,0
690,0
950,0
1300,0
1980,0
2350,0
3100,0
560,0
650,0
750,0
910,0
850,0
1000,0

AWG-No.
4/0
4/0
16
14
12
10
8
6
4
2
1
16
14
16
14
16
14

Dimensions and specifications may be changed without prior notice. (RQ02)

Bundling, binding, fastening


Plastic helix
Cable tie
Hook and loop cable tie
Mounting block

You can nd bundling, binding, fastening in our catalogue Cable Accessories.

Q 44
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NHXCH-FE 180/E 90 security cable, halogen-free, 0,6/1kV,


with improved fire characteristics


Technical data

Cable structure

Properties

Halogen-free security cable with improved


characteristics in the case of fire to
DINVDE0266
Insulation integrity
180 minutes to DINVDE0472 part814
Functionality
90 minutes to DINVDE4102 part12
Temperature range
-30 C to +70 C
Permissible operating temperature
at conductor +90 C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4000 V
Minimum bending radius
approx. 12x cable
Radiation resistance
up to 200x106 cJ/kg (up to 200 Mrad)
Caloric load values
see Technical Informations

Bare copper conductor, solid or stranded,


to DINVDE0295 cl.1 and cl.2, BS6360 cl.1
or 2, IEC60228 cl.1 or cl.2, HD383
Double core insulation of mica tape and
cross-linked polymer HI1, to DINVDE0207
part23
Each single core covering with flame
resistant glass-fibre tape
Colour coding of cores according to
DINVDE0293-308
Cores stranded in layer
Core wire screening with helix of copper
tape
Bare copper wire screening with helix of
copper tape
Outer jacket orange, polyolefin compound
HM4, to DINVDE0207 part24
Tests
Flame test to VDE 0482 part 266-2, BS 4066
part 3/ DIN EN 50266-2/ IEC 60332-3
(equivalent DIN VDE 0472 part 804 test
method C)
Corrosiveness of combustion gases
according to VDE 0482 part 267/ DIN EN
50267-2-2/ IEC 60754-2 (equivalent DIN VDE
0472 part 813)
Halogen-free according to VDE 0482 part
267/ DIN EN 50267-2-1/ IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density according to VDE 0482 part
1034-1+2/ IEC 61034-1+2/ DIN EN
61034-1+2/ BS 7622 part 1+2 (equivalent
DIN VDE 0472 part 816)
Insulation integrity under flame
propagation to VDE 0472 part 814 IEC
60331
Functionality of the complete cable
system to DIN4102 part 12 (90 minutes)

Halogen-free; no evolution of corrosive


and toxic gases
Flame retardant
Hardly flammable
Self-extinguished and fire resistant
No flame propagation, therefore security
from fire
Low smoke density, no darkening of
emergency exits without hindering the fire
extinguishing works
Toxicological harmless
No self-ignition
Maintenance of functionallity during the
increased current load
FE180: Insulation integrity for
180minutes. Tests to DINVDE0472
part814 IEC60331.
Insulation integrity under direct flame
propagation for the test period of
180minutes.
E90: Functionality of electrical cable
systems for minimum 90minutes. Test
method to DIN4102 part12. This fulfils the
demands of technical guide lines for fire
protection (supplement 1 to DINVDE0108
part1).
The functionality for 90minutes assures
the functional performance of
water-pressure-rising stations for the
supply to avoid smoke and heat in
safety-stairs and inner rooms, ladder shafts
and engine rooms for fire brigade lifts,
emergency lifts for sickbeds in hospitals
and the fire brigade lifts.


Note

re = round solid core;


rm = stranded core.

Application
Everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a special significance,
e.g. in industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals and
outpatients clinic (DINVDE0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings,
schools etc. (DINVDE0108), mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm
systems. Suitable for fixed installation in dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete.
For the installation in conduit all precautions must be taken that no accumulation of water can occur in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
53032
53033
53034
53035
53036
53037
53038
53039
53040
53041

No.cores x
cross-sec.
mm
3x1,5 / 1,5  re
3x2,5 / 2,5  re
3x4 / 4  re
3x6 / 6  re
3x10 / 10  re
3x16 / 16  rm
3x25 / 16  rm
3x35 / 16  rm
3x50 / 25  rm
3x70 / 35  rm

Outer
approx.
mm
16,9
18,0
19,0
20,1
22,0
24,0
28,0
30,0
34,0
38,0

Cop.
weight
kg/km
66,0
104,0
161,0
240,0
408,0
643,0
902,0
1190,0
1723,0
2410,0

Weight
approx.
kg/km
380,0
430,0
530,0
640,0
850,0
1150,0
1700,0
2150,0
2800,0
3800,0

AWG-No.
16
14
12
10
8
6
4
2
1
2/0


Part no.
53042
53043
53044
53045
53046
53047

No.cores x
cross-sec.
mm
3x95 / 50  rm
3x120 / 70  rm
3x150 / 70  rm
3x185 / 95  rm
3x240 / 120  rm
4x1,5 / 1,5  re

Outer
approx.
mm
44,0
47,0
51,0
56,0
65,0
18,0

Cop.
weight
kg/km
3296,0
4236,0
4992,0
6383,0
8242,0
81,0

Weight
approx.
kg/km
5100,0
6250,0
6900,0
8550,0
11150,0
435,0

AWG-No.
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
16

Continuation

Q 45
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NHXCH-FE 180/E 90 security cable, halogen-free, 0,6/1kV,


with improved fire characteristics




Part no.
53048
53049
53050
53051
53052
53053
53054
53055
53056
53057
53058
53059
53060
53061
53062
53066

No.cores x
cross-sec.
mm
4x2,5 / 2,5  re
4x4 / 4  re
4x6 / 6  re
4x10 / 10  re
4x16 / 16  rm
4x25 / 16  rm
4x35 / 16  rm
4x50 / 25  rm
4x70 / 35  rm
4x95 / 50  rm
4x120 / 70  rm
4x150 / 70  rm
4x185 / 95  rm
4x240 / 120  rm
7x1,5 / 2,5  re
7x2,5 / 2,5  re

Outer
approx.
mm
18,9
20,0
21,0
23,0
25,0
30,0
33,0
37,0
42,0
47,0
51,0
56,0
68,0
70,0
21,0
21,0

Cop.
weight
kg/km
128,0
200,0
297,0
504,0
796,0
1142,0
1526,0
2203,0
3082,0
4208,0
5388,0
6540,0
8159,0
10546,0
133,0
200,0

Weight
approx.
kg/km
500,0
610,0
740,0
1050,0
1350,0
1950,0
2400,0
3200,0
4300,0
5750,0
7100,0
8550,0
10700,0
13930,0
680,0
680,0

AWG-No.
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
16
14


Part no.
53063
53067
53064
53068
53065
53069

No.cores x
cross-sec.
mm
12x1,5 / 2,5  re
12x2,5 / 4  re
24x1,5 / 6  re
24x2,5 / 10  re
30x1,5 / 6  re
30x2,5 / 10  re

Outer
approx.
mm
27,0
28,0
37,0
37,5
39,0
39,5

Cop.
weight
kg/km
205,0
334,0
413,0
696,0
499,0
840,0

Weight
approx.
kg/km
1050,0
1050,0
1900,0
1900,0
2200,0
2200,0

AWG-No.
16
14
16
14
16
14

Dimensions and specifications may be changed without prior notice. (RQ02)

Marking
Marking rings
Cable marker
Indian pen

You can nd marking in our catalogue Cable Accessories.

Q 46
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XSY
NA2XSY
N2XS2Y
NA2XS2Y
N2XS(F)2Y
NA2XS(F)2Y

6/10kV, 12/20kV, 18/30kV


6/10kV, 12/20kV, 18/30kV
6/10kV, 12/20kV, 18/30kV
6/10kV, 12/20kV, 18/30kV
6/10kV, 12/20kV, 18/30kV
6/10kV, 12/20kV, 18/30kV
N2XSEY 3 x 6/10kV
Photo: HELUKABEL

Medium Voltage Power Cables

Q 47
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Medium Voltage Power Cables

XLPE-insulated

6/10 kV, 12/20 kV, 18/30 kV


Since about 1970 the cross-linked polyethylene
(XLPE)-insulated power cables have been used in
Germany. The XLPE-insulation possesses very good
electrical, mechanical and thermal characteristics in
medium voltage networks. This type of insulation is
very chemically resistant and also resistant to cold.
Due to various advantages, the XLPE-insulated type
has vastly displaced the traditional classical paperinsulated types in many sectors.

Insulation

In order to prevent the penetration of moisture


and also to extend the duration of life, the XLPEinsu-lated medium voltage cables are designed with
longitudinally water-proof screen including an additional swell tape and a PE outer sheath.

Outer semi-conducting layer

The manufacture of this sheath is based on high


density polyethylene (HDPE), in which an additive
organic peroxide is mixed. Due to the heating and
pressure the molecule chains are joined to each
other, assuring the transition from thermoplastic to
elastic condition.
In comparison to PVC and paper-insulated cables,
the advantage of XLPE-insulated medium voltage
power cables is that they possess a low dielectric
factor, such as it is 100 times smaller than of PVCinsulated cables.
Moreover, a better dielectric constant value has an
effect on the low mutual capacitance, the shortcircuit to ground and the charging current of XLPEinsulated cables.
The good properties of XLPE-insulated cables remain
constant through a wide temperature range.
Characteristics of XLPE

Cross-linked polyethylene (XLPE), compound


type 2XI1 according to DIN VDE 0207 part 22
and HD 620.1.
Insulation nominal wall-thickness
for
6/10 kV = 3,4 mm
12/20 kV = 5,5 mm
18/30 kV = 8,0 mm

Outer semi-conducting layer is extruded together


with the inner semi-conducting layer and the
insulation in one working process and are spliced
with each other.
Semi-conducting compound, cross-linked, wallthickness 0,3 to 0,6 mm.
Concentricity of conductor
The difference between the maximum and
mini-mum value of 0,5 mm should not be
exceeded.
Semi-conducting type
Over the outer semi-conducting layer, a semi-conducting tape must be used.
Screen
Screening of copper wires must have a minimum
diameter of 0,5 mm and over that a copper tape
applied helically with a minimum thickness of
0,1 mm.
Copper cross-section according to DIN VDE 0273
and 0276 to the corresponded table 2.

permissible operating temperature


For permanent (normal) operation
+ 90C
In short circuit
+250C
In overload operation and
damage by sea
up to +130C

Separator

Specic heat resistance


Dielectric constant
Specic resistance (20C)
Loss factor (tan ) (20C)
Density
Breaking strength
Tensile strength

PE compound DMP2 according to HD 620.1 and


2YM3 to DIN VDE 0276 part 3, black or
PVC compound DMV6 according to HD 620.1 and
YM5 to DIN VDE 0207 part 5, red
Wall-thickness = 2,5 mm,
for 1x 500 mm2 /30 kV = 2,6 mm

3,5 K m/W
2,4
min. 1016 Ohm cm
max. 0,5 103
0,92 g/cm3
min. 200%
min. 12,5 N/mm2

Over the screen as well as under outer jacket,


a separating layer must be used (e. g. taping).

Outer jacket

Conductor
Copper or aluminium, round, multiwire stranded
and compact, according to VDE 0295 and HD 383.
Inner semi-conducting layer
Semi-conducting compound, cross-linked,
mini-mum wall-thickness 0,3 mm.

Continuation

Q 48
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Medium Voltage Power Cables XLPE-insulated


6/10 kV, 12/20 kV, 18/30 kV
Laying of Cable

Laying in conduits

In order to avoid any damage, the XLPE-insulated


medium voltage cables should carefully laid and
installed. It must be ensured that the cables should
not be pulled over the hard or sharp edges.
The cable ends must be water-tight-sealed.
After cutting the length both ends must be
sealed immediately.
A laying depth of 60 to 80 cm is recommended.
Single conductor cables are normally arranged in a
trefoil touching or triangular shape.
For laying in conduits, the inuence of thermal
insulation of air space between the cable and the
inner wall of conduit should be specially considered.
The inner diameter of the conduit should be at least
1,5 times that of the diameter of the cable.

Cables for conduit systems laying in earth, a reduction of the current carrying capacity with a factor of
0,85 is recommended.

U0/U = 18/30 kV

Voltage test in kV
U0/U = 12/20 kV

During the laying of XLPE cables, the bending radius


should not be below of the following values:
Cable without metal sheath
= 15 x cable
Cable with Alu-laminated sheath
= 30 x cable

Kind of
voltage test

U0/U = 6/10 kV

Bending radius

Test voltages

Voltage test a. c. in kV

15

30

45

Voltage test d. c. in kV

48

96

144

Voltage test a. c.
(voltage test = 1000 h)

18

36

54

Temperature range

P = No. of cores x conductor cross-section x 


 = permissible pulling tension N/mm2
For Cu-conductor: 50 N/mm2
For Alu-conductor: 30 N/mm2

Kind of
voltage test

U0/U = 18/30 kV

By pulling the conductors with a pulling head (not


for armoured cables)

During the operation or after laying the medium


voltage power cables, the dielectric can be tested
with alternating or direct current. The test duration
continues 30 minutes.
U0/U = 12/20 kV

Max. permissible tensile strength

Voltage test to cable system

U0/U = 6/10 kV

During the installation, the temperature should not


be below the following values:
for XLPE-insulation + PVC jacket
= 5C
for XLPE-insulation + PE jacket
= 20C

12

24

36

Current carrying capacity


according to VDE 0276 part 620, 5C or HD 620 S1

Voltage test a. c.
in kV

Laying in earth (ground)


Laying depth
Earth temperature
in the laying depth
Specic heat resistance
Load factor

0,7 0,8 m
20C
1,0 K m/W
0,7 (EVU-Load)

Voltage test d. c.
in kV

34
67
76
up to 48 up to 96 up to 108

Laying in air
Air temperature
Load factor (permanent load)

30C
1,0

Q 49
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XSY 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


Cu-conductor, single core, screened, PVC-jacket


Technical data

Cable structure

Properties

XLPE-insulated power cables to


DINVDE0276 part620, HD620S1 and
IEC60502
Temperature range
during installation up to -5 C
Operating temperature
max. 90 C
Short circuit temperature
250 C (short circuit duration up to 5 sec.)
Nominal voltages
U0/U 6/10 kV, 12/20 kV, 18/30 kV
Operating voltages for
6/10 kV = max. 12 kV
12/20 kV = max. 24 kV
18/30 kV = max. 36 kV
Test voltages for
6/10 kV = 15 kV
12/20 kV = 30 kV
18/30 kV = 45 kV
Minimum bending radius
during installation max. 15x cable
Power ratings table
see Technical Informations

Circular bare Cu-conductor of stranded


wires to HD383
Inner semi-conducting coating
Core insulation of cross-linked Polyethylene
(XLPE), PE-compound DIX8 to HD620.1
Outer extrusion of semi-conducting
coating spliced with the insulation
Wrapping of conductive material
Screen: Braiding of copper wires with one
or two tape(s) applied helically
Wrapping
PVC outer jacket, compound DMV6 to
HD620.1
Jacket colour red

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Installation notes
To guarantee an optimum on operating
reliability the extruded semi-conductive
layer is spliced with the insulation for long
duration. For this reason we recommend
a peeling tool for installation.


Note

Further dimensions available on request.

Application
Suitable for installation mostly for power supply stations, in indoors and in cable ducts, outdoors, underground and in water as well as for
installation on cable trays for industries, switch-boards and power stations. Due to the good laying characteristic, this can also be laid easily
in difficult line guideways.
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE
insulation assures a construction free of partial discharges with high operational reliability.



Part no.

32400
32401
32402
32403
32404
32406
32405
32408
32407
32409
32410
32411
32412
32413
32414
32415
32416
32417
32418
32419
32420
32422
32421
32424
32423
32425
32426
32427
32428
32429

No.cores x
cross-sec.
mm
1x35
1x50
1x70
1x95
1x120
1x150
1x150
1x185
1x185
1x240
1x240
1x300
1x400
1x500
1x35
1x50
1x70
1x95
1x120
1x150
1x150
1x185
1x185
1x240
1x240
1x300
1x400
1x500
1x50
1x70

Operation
voltage
max.
rm / 16
rm / 16
rm / 16
rm / 16
rm / 16
rm / 25
rm / 16
rm / 25
rm / 16
rm / 16
rm / 25
rm / 25
rm / 35
rm / 35
rm / 16
rm / 16
rm / 16
rm / 16
rm / 16
rm / 16
rm / 25
rm / 25
rm / 16
rm / 25
rm / 16
rm / 25
rm / 35
rm / 35
rm / 16
rm / 16

12
12
12
12
12
12
12
12
12
12
12
12
12
12
24
24
24
24
24
24
24
24
24
24
24
24
24
24
36
36

Nominal
voltage
kV
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
18 / 30
18 / 30

Insulation
thickness
mm
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
8
8

Jacket
thickness
Nominal
value
mm
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5

Outer
min. - max.
mm
23,0 - 28,0
24,0 - 29,0
26,0 - 31,0
26,0 - 32,0
28,0 - 34,0
29,0 - 35,0
29,0 - 35,0
31,0 - 37,0
31,0 - 37,0
33,0 - 39,0
33,0 - 39,0
36,0 - 41,0
40,0 - 45,0
43,0 - 48,0
27,0 - 32,0
28,0 - 33,0
30,0 - 35,0
31,0 - 36,0
32,0 - 38,0
33,0 - 39,0
33,0 - 39,0
35,0 - 41,0
35,0 - 41,0
38,0 - 44,0
38,0 - 44,0
40,0 - 46,0
43,0 - 49,0
46,0 - 52,0
32,0 - 38,0
34,0 - 40,0

Cop.
weight
kg/km
518,0
662,0
854,0
1094,0
1334,0
1723,0
1622,0
2059,0
1958,0
2486,0
2587,0
3163,0
4234,0
5194,0
518,0
662,0
854,0
1094,0
1334,0
1622,0
1723,0
2059,0
1958,0
2587,0
2486,0
3163,0
4234,0
5194,0
662,0
854,0

Weight
approx.
kg/km
905,0
1080,0
1310,0
1580,0
1860,0
2210,0
2040,0
2580,0
2450,0
3000,0
3130,0
3780,0
4670,0
5750,0
1110,0
1250,0
1510,0
1780,0
2070,0
2310,0
2420,0
2810,0
2650,0
3360,0
3260,0
4020,0
4930,0
6050,0
1480,0
1730,0

AWG-No.

2
1
2/0
3/0
4/0
300 kcmil
300 kcmil
350 kcmil
350 kcmil
500 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
2
1
2/0
3/0
4/0
300 kcmil
300 kcmil
350 kcmil
350 kcmil
500 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
1
2/0

Continuation

Q 50
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XSY 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


Cu-conductor, single core, screened, PVC-jacket


Part no.

32430
32431
32432
32433
32434
32435
32436
32437

No.cores x
cross-sec.
mm
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500

Operation
voltage
max.
rm / 16
rm / 16
rm / 25
rm / 25
rm / 25
rm / 25
rm / 35
rm / 35

36
36
36
36
36
36
36
36

Nominal
voltage
kV
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30

Insulation
thickness
mm
8
8
8
8
8
8
8
8

Jacket
thickness
Nominal
value
mm
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5

Outer
min. - max.
mm
35,0 - 41,0
37,0 - 43,0
38,0 - 44,0
40,0 - 46,0
42,0 - 48,0
45,0 - 51,0
48,0 - 54,0
51,0 - 57,0

Cop.
weight
kg/km
1094,0
1334,0
1723,0
2059,0
2587,0
3163,0
4234,0
5194,0

Weight
approx.
kg/km
2060,0
2330,0
2720,0
3100,0
3730,0
4000,0
5330,0
6480,0

AWG-No.

3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil

Dimensions and specifications may be changed without prior notice. (RQ03)

Core end sleeves and cable lugs


Core end sleeves
Solderless terminals
Tubular cable lugs
Compression joints

You can nd core end sleeves and cable lugs in our catalogue Cable Accessories.

Q 51
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NA2XSY 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


alu-conductor, single core, screened, PVC-jacket


Technical data

Cable structure

Properties

XLPE-insulated power cables to


DINVDE0276 part620, HD620S1 and
IEC60502
Temperature range
during installation up to -5 C
Operating temperature
max. 90 C
Short circuit temperature 250 C
(short circuit duration up to 5 sec.)
Nominal voltages
U0/U 6/10 kV, 12/20 kV, 18/30 kV
Operating voltages for
6/10 kV = max. 12 kV
12/20 kV = max. 24 kV
18/30 kV = max. 36 kV
Test voltages for
6/10 kV = 15 kV
12/20 kV = 30 kV
18/30 kV = 45 kV
Minimum bending radius
during installation max. 15x cable
Power ratings
see Technical Informations

Circular bare alu-conductor of stranded


wires to HD383
Inner semi-conducting coating
Core insulation of cross-linked Polyethylene
(XLPE), PE-compound DIX8 to HD620.1
Outer extrusion of semi-conducting
coating spliced with the insulation
Wrapping of conductive material
Screen: Braiding of copper wires with one
or two tapes applied helically
Wrapping
PVC outer jacket, compound DMV6 to
HD620.1
Jacket colour red

self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Installation notes
To guarantee an optimum on operating
reliability the extruded semi-conductive
layer is spliced with the insulation for long
duration. For this reason we recommend
a peeling tool for installation


Note

Further dimensions available on request.

Application
Suitable for installation mostly for power supply stations, in indoors and in cable ducts, outdoors, underground and in water as well as for
installation on cable trays for industries, switch-boards and power stations. Due to the good laying characteristic, this can also be laid easily
in difficult line guideways.
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE
insulation assures a construction free of partial discharges with high operational reliability.



Part no.

32440
32441
32442
32443
32445
32444
32447
32446
32449
32448
32450
32451
32452
32453
32454
32455
32456
32457
32458
32459
32460
32462
32461
32463
32464
32465
32466
32467

No.cores x
cross-sec.
mm
1x50
1x70
1x95
1x120
1x150
1x150
1x185
1x185
1x240
1x240
1x300
1x400
1x500
1x50
1x70
1x95
1x120
1x150
1x150
1x185
1x185
1x240
1x240
1x300
1x400
1x500
1x50
1x70

Operation
voltage
max.
rm / 16
rm / 16
rm / 16
rm / 16
rm / 25
rm / 16
rm / 25
rm / 16
rm / 25
rm / 16
rm / 25
rm / 35
rm / 35
rm / 16
rm / 16
rm / 16
rm / 16
rm / 16
rm / 25
rm / 16
rm / 25
rm / 25
rm / 16
rm / 25
rm / 35
rm / 35
rm / 16
rm / 16

12
12
12
12
12
12
12
12
12
12
12
12
12
24
24
24
24
24
24
24
24
24
24
24
24
24
36
36

Nominal
voltage
kV
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
18 / 30
18 / 30

Insulation
thickness
mm
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
8
8

Jacket
thickness
Nominal
value
mm
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5

Outer
Cop.
min. - max. weight
mm
kg/km
24,0 - 29,0
26,0 - 31,0
26,0 - 32,0
28,0 - 34,0
29,0 - 35,0
29,0 - 35,0
31,0 - 37,0
31,0 - 37,0
33,0 - 39,0
33,0 - 39,0
36,0 - 41,0
40,0 - 45,0
43,0 - 48,0
28,0 - 33,0
30,0 - 35,0
31,0 - 36,0
32,0 - 38,0
33,0 - 39,0
33,0 - 39,0
35,0 - 41,0
35,0 - 41,0
38,0 - 44,0
38,0 - 44,0
40,0 - 46,0
43,0 - 49,0
46,0 - 52,0
32,0 - 38,0
34,0 - 40,0

182,0
182,0
182,0
182,0
283,0
182,0
283,0
182,0
283,0
182,0
283,0
394,0
394,0
182,0
182,0
182,0
182,0
182,0
283,0
182,0
283,0
283,0
182,0
283,0
394,0
394,0
182,0
182,0

Alu weight Weight


kg/km
approx.
kg/km
145,0
203,0
276,0
348,0
435,0
435,0
537,0
537,0
696,0
696,0
870,0
1160,0
1450,0
145,0
203,0
276,0
348,0
435,0
435,0
537,0
537,0
696,0
696,0
870,0
1160,0
1450,0
145,0
203,0

780,0
875,0
990,0
1110,0
1310,0
1240,0
1460,0
1405,0
1660,0
1615,0
1910,0
2315,0
2750,0
950,0
1110,0
1220,0
1310,0
1460,0
1520,0
1660,0
1720,0
1910,0
1860,0
2220,0
2620,0
3030,0
1260,0
1360,0

AWG-No.

1
2/0
3/0
4/0
300 kcmil
300 kcmil
350 kcmil
350 kcmil
500 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
1
2/0
3/0
4/0
300 kcmil
300 kcmil
350 kcmil
350 kcmil
500 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
1
2/0

Continuation

Q 52
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NA2XSY 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


alu-conductor, single core, screened, PVC-jacket


Part no.

32468
32469
32470
32471
32472
32473
32475
32474
32476
32477
32478

No.cores x
cross-sec.
mm
1x95
1x120
1x150
1x150
1x185
1x185
1x240
1x240
1x300
1x400
1x500

Operation
voltage
max.
rm / 16
rm / 16
rm / 16
rm / 25
rm / 16
rm / 25
rm / 25
rm / 16
rm / 25
rm / 35
rm / 35

36
36
36
36
36
36
36
36
36
36
36

Nominal
voltage
kV
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30

Insulation
thickness
mm
8
8
8
8
8
8
8
8
8
8
8

Jacket
thickness
Nominal
value
mm
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,6

Outer
Cop.
min. - max. weight
mm
kg/km
35,0 - 41,0
37,0 - 43,0
38,0 - 44,0
38,0 - 44,0
40,0 - 46,0
40,0 - 46,0
42,0 - 48,0
42,0 - 48,0
45,0 - 51,0
48,0 - 54,0
51,0 - 57,0

182,0
182,0
182,0
283,0
182,0
283,0
283,0
182,0
283,0
394,0
394,0

Alu weight Weight


kg/km
approx.
kg/km
276,0
348,0
435,0
435,0
537,0
537,0
696,0
696,0
870,0
1160,0
1450,0

1510,0
1610,0
1760,0
1810,0
1960,0
2020,0
2260,0
2210,0
2560,0
2960,0
3460,0

AWG-No.

3/0
4/0
300 kcmil
300 kcmil
350 kcmil
350 kcmil
500 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil

Dimensions and specifications may be changed without prior notice. (RQ03)

Tools
Cable shears
Box spanners
Strippers
Crimping tools
Pliers
Skinning knife

You can nd tools in our catalogue Cable Accessories.

Q 53
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XS2Y 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


Cu-conductor, single core, screened, PE-jacket


Technical data

Cable structure

Properties

XLPE-insulated power cables to IEC60502,


DINVDE0276 part620, HD620S1
Temperature range
during installation up to -20 C
Operating temperature
max. 90 C
Short circuit temperature
250 C (short circuit duration up to 5 sec.)
Nominal voltages
U0/U 6/10 kV, 12/20 kV, 18/30 kV
Operating voltages for
6/10 kV = max. 12 kV
12/20 kV = max. 24 kV
18/30 kV = max. 36 kV
Test voltages for
6/10 kV = 15 kV
12/20 kV = 30 kV
18/30 kV = 45 kV
Minimum bending radius
during installation max. 15x cable
Power ratings
table see Technical Informations

Circular bare cu-conductor of stranded


wires to HD383
Inner semi-conducting coating
Core insulation of cross-linked Polyethylene
(XLPE), PE-compound DIX8 to HD620.1
Outer extrusion of semi-conducting
coating spliced with the insulation
Wrapping of conductive material
Screen: Braiding of copper wires with one
or two tapes applied helically
Wrapping
PE-outer jacket black, compound DMP2 to
HD620.1
Jacket colour black

The materials used in manufacture are


cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Installation notes
To guarantee an optimum on operating
reliability the extruded semi-conductive
layer is spliced with the insulation for long
duration. For this reason we recommend
a peeling tool for installation.


Note

Further dimensions available on request.

Application
Suitable for indoor installation and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries,
switch-boards and power stations. The PE-outer jacket is resistant to high mechanical stress for laying the cables. This PE-jacket is not
flame-resistant (does not conform the test method B, as per VDE0472 part804).
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE
insulation assures a construction free of partial discharges with high operational reliability.



Part no.

32480
32481
32482
32483
32484
32485
32486
32488
32487
32489
32490
32491
32492
32493
32494
32495
32496
32497
32498
32500
32499
32502
32501
32503
32504
32505
32506
32507
32508
32509

No.cores x
cross-sec.
mm
1x35
1x50
1x70
1x95
1x120
1x150
1x150
1x185
1x185
1x240
1x240
1x300
1x400
1x500
1x35
1x50
1x70
1x95
1x120
1x150
1x150
1x185
1x185
1x240
1x240
1x300
1x400
1x500
1x50
1x70

Operation
voltage
max.
rm / 16
rm / 16
rm / 16
rm / 16
rm / 16
rm / 16
rm / 25
rm / 25
rm / 16
rm / 16
rm / 25
rm / 25
rm / 35
rm / 35
rm / 16
rm / 16
rm / 16
rm / 16
rm / 16
rm / 25
rm / 16
rm / 25
rm / 16
rm / 16
rm / 25
rm / 25
rm / 35
rm / 35
rm / 16
rm / 16

12
12
12
12
12
12
12
12
12
12
12
12
12
12
24
24
24
24
24
24
24
24
24
24
24
24
24
24
36
36

Nominal
voltage
kV
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
18 / 30
18 / 30

Insulation
thickness
mm
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
8
8

Jacket
thickness
Nominal
value
mm
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5

Outer
min. - max.
mm
23,0 - 28,0
24,0 - 29,0
26,0 - 31,0
26,0 - 32,0
28,0 - 34,0
29,0 - 35,0
29,0 - 35,0
31,0 - 37,0
31,0 - 37,0
33,0 - 39,0
33,0 - 39,0
36,0 - 41,0
40,0 - 45,0
43,0 - 48,0
27,0 - 32,0
28,0 - 33,0
30,0 - 35,0
31,0 - 36,0
33,0 - 38,0
34,0 - 39,0
34,0 - 39,0
36,0 - 41,0
36,0 - 41,0
39,0 - 44,0
39,0 - 44,0
41,0 - 46,0
44,0 - 49,0
47,0 - 52,0
32,0 - 38,0
34,0 - 40,0

Cop.
weight
kg/km
518,0
662,0
854,0
1098,0
1334,0
1622,0
1725,0
2059,0
1958,0
2486,0
2587,0
3163,0
4234,0
5194,0
518,0
662,0
854,0
1094,0
1334,0
1723,0
1622,0
2059,0
1958,0
2486,0
2587,0
3163,0
4234,0
5194,0
662,0
854,0

Weight
approx.
kg/km
910,0
990,0
1205,0
1520,0
1760,0
2020,0
2130,0
2470,0
2360,0
2960,0
3020,0
3630,0
4560,0
5580,0
960,0
1160,0
1410,0
1670,0
1960,0
2310,0
2220,0
2670,0
2620,0
3160,0
3270,0
3880,0
4820,0
5860,0
1410,0
1660,0

AWG-No.

2
1
2/0
3/0
4/0
300 kcmil
300 kcmil
350 kcmil
350 kcmil
500 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
2
1
2/0
3/0
4/0
300 kcmil
300 kcmil
350 kcmil
350 kcmil
500 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
1
2/0

Continuation

Q 54
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XS2Y 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


Cu-conductor, single core, screened, PE-jacket


Part no.

32510
32511
32512
32513
32514
32515
32516
32517

No.cores x
cross-sec.
mm
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500

Operation
voltage
max.
rm / 16
rm / 16
rm / 25
rm / 25
rm / 25
rm / 25
rm / 35
rm / 35

Nominal
voltage
kV

36
36
36
36
36
36
36
36

18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30

Insulation
thickness
mm
8
8
8
8
8
8
8
8

Jacket
thickness
Nominal
value
mm
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5

Outer
min. - max.
mm
35,0 - 41,0
37,0 - 43,0
38,0 - 44,0
40,0 - 46,0
42,0 - 48,0
45,0 - 51,0
48,0 - 54,0
51,0 - 57,0

Cop.
weight
kg/km
1094,0
1334,0
1723,0
2059,0
2587,0
3163,0
4234,0
5194,0

Weight
approx.
kg/km
1970,0
2220,0
2650,0
2980,0
3570,0
4220,0
5170,0
6260,0

AWG-No.

3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil

Dimensions and specifications may be changed without prior notice. (RQ03)

Signal and power circular connectors


Series A, B, C, D, F and S
Tools
Accessories
Online congurator
Pre-assembled cables

You can nd signal and power circular connectors in our catalogue Cable Accessories.

Q 55
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NA2XS2Y 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


Cu-conductor, single core, screened, PE-jacket


Technical data

Cable structure

Properties

XLPE-insulated power cables to


DINVDE0276 part620, HD620S1 and
IEC60502
Temperature range
during installation up to -20 C
Operating temperature
max. 90 C
Short circuit temperature
250 C (short circuit duration up to 5 sec.)
Nominal voltages
U0/U 6/10 kV, 12/20 kV, 18/30 kV
Operating voltages for
6/10 kV = max. 12 kV
12/20 kV = max. 24 kV
18/30 kV = max. 36 kV
Test voltages for
6/10 kV = 15 kV
12/20 kV = 30 kV
18/30 kV = 45 kV
Minimum bending radius
during installation max. 15x cable
Power ratings
table see Technical Informations

Circular bare alu-conductor of stranded


wires to HD383
Inner semi-conducting coating
Core insulation of cross-linked Polyethylene
(XLPE), PE-compound DIX8 to HD620.1
Outer extrusion of semi-conducting
coating spliced with the insulation
Wrapping of conductive material
Screen: Braiding of copper wires with one
or two tapes applied helically
Wrapping
PE-outer jacket black, compound DMP2 to
HD620.1
Jacket colour black

The materials used in manufacture are


cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Installation notes
To guarantee an optimum on operating
reliability the extruded semi-conductive
layer is spliced with the insulation for long
duration. For this reason we recommend
a peeling tool for installation.


Note

Further dimensions available on request.

Application
Suitable for indoor installation and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries,
switch-boards and power stations. The PE-outer jacket is resistant to high mechanical stress for laying the cables. This PE-jacket is not
flame-resistant (does not conform the test method B, as per VDE0472 part804).
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE
insulation assures a construction free of partial discharges with high operational reliability.



Part no.

32520
32521
32522
32523
32524
32525
32527
32526
32528
32529
32530
32531
32532
32533
32534
32535
32536
32538
32537
32540
32539
32542
32541
32543
32544
32545
32546
32547

No.cores x
cross-sec.
mm
1x50
1x70
1x95
1x120
1x150
1x150
1x185
1x185
1x240
1x240
1x300
1x400
1x500
1x50
1x70
1x95
1x120
1x150
1x150
1x185
1x185
1x240
1x240
1x300
1x400
1x500
1x50
1x70

Operation
voltage
max.
rm / 16
rm / 16
rm / 16
rm / 16
rm / 16
rm / 25
rm / 25
rm / 16
rm / 16
rm / 25
rm / 25
rm / 35
rm / 35
rm / 16
rm / 16
rm / 16
rm / 16
rm / 25
rm / 16
rm / 25
rm / 16
rm / 25
rm / 16
rm / 25
rm / 35
rm / 35
rm / 16
rm / 16

12
12
12
12
12
12
12
12
12
12
12
12
12
24
24
24
24
24
24
24
24
24
24
24
24
24
36
36

Nominal
voltage
kV
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
18 / 30
18 / 30

Insulation
thickness
mm
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
8
8

Jacket
thickness
Nominal
value
mm
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5

Outer
Cop.
min. - max. weight
mm
kg/km
24,0 - 29,0
26,0 - 31,0
26,0 - 32,0
28,0 - 34,0
29,0 - 35,0
29,0 - 35,0
33,0 - 39,0
31,0 - 37,0
33,0 - 39,0
33,0 - 39,0
36,0 - 41,0
40,0 - 45,0
43,0 - 48,0
28,0 - 33,0
30,0 - 35,0
31,0 - 36,0
32,0 - 38,0
33,0 - 39,0
33,0 - 39,0
35,0 - 41,0
35,0 - 41,0
38,0 - 44,0
38,0 - 44,0
40,0 - 46,0
43,0 - 49,0
46,0 - 52,0
32,0 - 38,0
34,0 - 40,0

182,0
182,0
182,0
182,0
182,0
283,0
283,0
182,0
182,0
283,0
283,0
394,0
394,0
182,0
182,0
182,0
182,0
283,0
182,0
283,0
182,0
283,0
182,0
283,0
394,0
394,0
182,0
182,0

Alu weight Weight


kg/km
approx.
kg/km
145,0
203,0
276,0
348,0
435,0
435,0
537,0
537,0
696,0
696,0
870,0
1160,0
1450,0
145,0
203,0
276,0
348,0
435,0
435,0
537,0
537,0
696,0
696,0
870,0
1160,0
1450,0
145,0
203,0

710,0
790,0
920,0
990,0
1110,0
1220,0
1370,0
1260,0
1480,0
1530,0
1820,0
2220,0
2570,0
890,0
970,0
1120,0
1210,0
1420,0
1370,0
1570,0
1530,0
1830,0
1720,0
2070,0
2460,0
2890,0
1120,0
1270,0

AWG-No.

1
2/0
3/0
4/0
300 kcmil
300 kcmil
350 kcmil
350 kcmil
500 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
1
2/0
3/0
4/0
300 kcmil
300 kcmil
350 kcmil
350 kcmil
500 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
1
2/0

Continuation

Q 56
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NA2XS2Y 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


Cu-conductor, single core, screened, PE-jacket


Part no.

32548
32549
32550
32551
32552
32553
32554
32555

No.cores x
cross-sec.
mm
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500

Operation
voltage
max.
rm / 16
rm / 16
rm / 25
rm / 25
rm / 25
rm / 25
rm / 35
rm / 35

36
36
36
36
36
36
36
36

Nominal
voltage
kV
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30

Insulation
thickness
mm
8
8
8
8
8
8
8
8

Jacket
thickness
Nominal
value
mm
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5

Outer
Cop.
min. - max. weight
mm
kg/km
35,0 - 41,0
37,0 - 43,0
38,0 - 44,0
40,0 - 46,0
42,0 - 48,0
45,0 - 51,0
48,0 - 54,0
51,0 - 57,0

182,0
182,0
283,0
283,0
283,0
283,0
394,0
394,0

Alu weight Weight


kg/km
approx.
kg/km
276,0
348,0
435,0
537,0
696,0
870,0
1160,0
1450,0

1380,0
1530,0
1720,0
1860,0
2110,0
2370,0
2820,0
3280,0

AWG-No.

3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil

Dimensions and specifications may be changed without prior notice. (RQ03)

Cable Glands
Cable glands for standard applications
Plastic Glands
Cable Glands of Brass
Accessories
Cable glands for special application conditions
for electromagnetic compatibility EMC
for rugged applications and special chemical resistance
for high temperature use
for explosive areas
for special mounting conditions
for special pressure conditions

You can nd cable glands in our catalogue Cable Accessories.

Q 57
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XS(F)2Y 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


Cu-conductor, single core, longitudinally water-tight, screened, PE-jacket


Technical data

Cable structure

Properties

XLPE-insulated power cables to


DINVDE0276 part620, HD620S1 and
IEC60502
Temperature range
during installation up to -20 C
Operating temperature
max. 90 C
Short circuit temperature
250 C (short circuit duration up to 5 sec.)
Nominal voltages
U0/U 6/10 kV, 12/20 kV, 18/30 kV
Operating voltages for
6/10 kV = max. 12 kV
12/20 kV = max. 24 kV
18/30 kV = max. 36 kV
Test voltages for
6/10 kV = 15 kV
12/20 kV = 30 kV
18/30 kV = 45 kV
Minimum bending radius
during installation max. 15x cable
Power ratings
table see Technical Informations

Circular bare Cu-conductor of stranded


wires to DINVDE0295 cl.2 bzw. IEC60228
cl.2
Inner semi-conducting coating
Core insulation of cross-linked Polyethylene
(XLPE), PE-compound DIX8 to HD620.1
Outer extrusion of semi-conducting
coating spliced with the XLPE-insulation
Longitudinally water-tight, conductive
wrapping
Screen: Braiding of copper wires with one
or two tapes applied helically
Longitudinally water-tight wrapping
PE-outer jacket, compound DMP2 to
HD620.1
Jacket colour black

The materials used in manufacture are


cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Installation notes
To guarantee an optimum on operating
reliability the extruded semi-conductive
layer is spliced with the insulation for long
duration. For this reason we recommend
a peeling tool for installation


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
For longitudinally and crosswise water-tight
cable type N2XS(FL)2Y with PE-copolymere
coated aluminium.
Further types and dimensions on request.

Application
Suitable for indoor installation and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries,
switch-boards and power stations. The PE-outer jacket is resistant to high mechanical stress for laying the cables. This PE-jacket is not
flame-resistant (does not conform the test method B, as per VDE0472 part804).
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE
insulation assures a construction free of partial discharges with high operational reliability.



Part no.

32560
32561
32562
32563
32564
32565
32566
32567
32568
32569
32570
32571
32572
32573
32574
32575
32576
32577
32578
32579
32580
32581
32582
32583

No.cores x
cross-sec.
mm
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x50
1x70

Operation
voltage
max.
rm / 16
rm / 16
rm / 16
rm / 16
rm / 16
rm / 25
rm / 25
rm / 25
rm / 25
rm / 35
rm / 35
rm / 16
rm / 16
rm / 16
rm / 16
rm / 16
rm / 25
rm / 25
rm / 25
rm / 25
rm / 35
rm / 35
rm / 16
rm / 16

12
12
12
12
12
12
12
12
12
12
12
24
24
24
24
24
24
24
24
24
24
24
36
36

Nominal
voltage
kV
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
18 / 30
18 / 30

Insulation
thickness
mm
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
8
8

Screen
cross-sec.
mm
16
16
16
16
16
25
25
25
25
35
35
16
16
16
16
16
25
25
25
25
35
35
16
16

Jacket
thickness
Nominal
value
mm
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5

Outer
approx.
mm
26,0
28,0
30,0
31,0
32,0
34,0
36,0
38,0
40,0
44,0
47,0
31,0
33,0
34,0
36,0
37,0
39,0
41,0
43,0
45,0
48,0
52,0
37,0
38,0

Cop.
weight
kg/km
518,0
662,0
854,0
1094,0
1334,0
1723,0
2059,0
2587,0
3163,0
4234,0
5194,0
518,0
662,0
854,0
1094,0
1334,0
1723,0
2059,0
2587,0
3163,0
4234,0
5194,0
662,0
854,0

Weight
approx.
kg/km
1050,0
1150,0
1460,0
1700,0
2030,0
2350,0
2700,0
3300,0
3900,0
4850,0
6000,0
1210,0
1400,0
1550,0
1800,0
2150,0
2400,0
2850,0
3250,0
3850,0
4900,0
6100,0
1700,0
1950,0

AWG-No.

2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
1
2/0

Continuation

Q 58
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XS(F)2Y 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


Cu-conductor, single core, longitudinally water-tight, screened, PE-jacket

Part no.

32584
32585
32586
32587
32588
32589
32590
32591

No.cores x
cross-sec.
mm
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500

Operation
voltage
max.
rm / 16
rm / 16
rm / 25
rm / 25
rm / 25
rm / 25
rm / 35
rm / 35

36
36
36
36
36
36
36
36

Nominal
voltage
kV
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30

Insulation
thickness
mm
8
8
8
8
8
8
8
8

Screen
cross-sec.
mm
16
16
25
25
25
25
35
35

Jacket
thickness
Nominal
value
mm
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5

Outer
approx.
mm
40,0
42,0
43,0
45,0
47,0
50,0
53,0
56,0

Cop.
weight
kg/km
1094,0
1334,0
1723,0
2059,0
2587,0
3163,0
4234,0
5194,0

Weight
approx.
kg/km
2300,0
2600,0
3000,0
3350,0
4100,0
4800,0
5750,0
6700,0

AWG-No.

3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil

Dimensions and specifications may be changed without prior notice. (RQ03)

Conduits
Corrugated tubes
for standard applications
for lager sizes
scissile corrugated tubes
conduit glands
High exible conduits
plastic conduits with spiral spring
metal conduits
conduits glands
Conduit for heavy mechanical duty
metal conduits with plastic sheat
plastic conduits
conduits glands for metal conduits

You can nd conduits in our catalogue Cable Accessories.

Q 59
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NA2XS(F)2Y 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


alu-conductor, single core, longitudinally water-tight, screened, PE-jacket


Technical data
XLPE-insulated power cables to
DINVDE0276 part620, HD620S1 and
IEC60502
Temperature range
during installation up to -20C
Operating temperature
max. 90C
Short circuit temperature
250C (short circuit duration up to 5 sec.)
Nominal voltages
U0/U 6/10 kV, 12/20 kV, 18/30 kV
Operating voltages for
6/10 kV = max. 12 kV
12/20 kV = max. 24 kV
18/30 kV = max. 36 kV
Test voltages for
6/10 kV = 15 kV
12/20 kV = 30 kV
18/30 kV = 45 kV
Minimum bending radius
during installation max. 15x cable
Power ratings
table see Technical Informations

Cable structure

Properties

Circular bare alu-conductor of stranded


wires to DINVDE0295 cl.2 and IEC60228
cl.2
Inner semi-conducting coating
Core insulation of cross-linked Polyethylene
(XLPE), PE-compound DIX8 to HD620.1
Outer extrusion of semi-conducting
coating spliced with the XLPE-insulation
Longitudinally water-tight, conductive
wrapping
Screen: Braiding of copper wires with one
or two tapes applied helically
Longitudinally water-tight wrapping
PE-outer jacket, compound DMP2 to
HD620.1
Jacket colour black
Jacket thickness voltage2,5mm

The materials used in manufacture are


cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Installation notes
To guarantee an optimum on operating
reliability the extruded semi-conductive
layer is spliced with the insulation for long
duration. For this reason we recommend
a peeling tool for installation.


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
For longitudinally and crosswise water-tight
cable type NA2XS(FL)2Y with PE-copolymere
coated aluminium.
Further types and dimensions on request.

Application
Suitable for indoor installation and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries,
switch-boards and power stations. The PE-outer jacket is resistant to high mechanical stress for laying the cables. This PE-jacket is not
flame-resistant (does not conform the test method B, as per VDE0472 part804).
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE
insulation assures a construction free of partial discharges with high operational reliability.



Part no.
32600
32601
32602
32603
32604
32605
32606
32607
32608
32609
32610
32611
32612
32613
32614
32615
32616
32617
32618
32619
32620
32621
32622

No.cores x
cross-sec.
mm
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x50
1x70

rm / 16
rm / 16
rm / 16
rm / 16
rm / 16
rm / 25
rm / 25
rm / 25
rm / 25
rm / 35
rm / 35
rm / 16
rm / 16
rm / 16
rm / 16
rm / 25
rm / 25
rm / 25
rm / 25
rm / 35
rm / 35
rm / 16
rm / 16

Operation
voltage
max.
12
12
12
12
12
12
12
12
12
12
12
24
24
24
24
24
24
24
24
24
24
36
36

Nominal
voltage
kV
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
6 / 10
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
12 / 20
18 / 30
18 / 30

Insulation
thickness
mm
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
8
8

Screen
cross-sec.
mm
16
16
16
16
16
25
25
25
25
35
35
16
16
16
16
25
25
25
25
35
35
16
16

Outer
approx.
mm
26,0
28,0
30,0
31,0
32,0
34,0
36,0
38,0
40,0
44,0
47,0
33,0
34,0
36,0
37,0
39,0
41,0
43,0
45,0
48,0
52,0
37,0
38,0

Cop.
weight
kg/km
182,0
182,0
182,0
182,0
182,0
283,0
283,0
283,0
283,0
394,0
394,0
182,0
182,0
182,0
182,0
283,0
283,0
283,0
283,0
394,0
394,0
182,0
182,0

Alu weight Weight


kg/km
approx.
kg/km
102,0
780,0
145,0
850,0
203,0
980,0
276,0
1080,0
348,0
1150,0
435,0
1280,0
537,0
1420,0
696,0
1630,0
870,0
1950,0
1160,0
2350,0
1450,0
2780,0
145,0
920,0
203,0
1030,0
276,0
1140,0
348,0
1250,0
435,0
1320,0
537,0
1570,0
696,0
1780,0
870,0
2100,0
1160,0
2480,0
1450,0
2900,0
145,0
1250,0
203,0
1500,0

AWG-No.
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
1
2/0

Continuation

Q 60
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

NA2XS(F)2Y 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


alu-conductor, single core, longitudinally water-tight, screened, PE-jacket


Part no.
32623
32624
32625
32626
32627
32628
32629
32630

No.cores x
cross-sec.
mm
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500

rm / 16
rm / 16
rm / 25
rm / 25
rm / 25
rm / 25
rm / 35
rm / 35

Operation
voltage
max.
36
36
36
36
36
36
36
36

Nominal
voltage
kV
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30
18 / 30

Insulation
thickness
mm
8
8
8
8
8
8
8
8

Screen
cross-sec.
mm
16
16
25
25
25
25
35
35

Outer
approx.
mm
40,0
42,0
43,0
45,0
47,0
50,0
53,0
56,0

Cop.
weight
kg/km
182,0
182,0
283,0
283,0
283,0
283,0
394,0
394,0

Alu weight Weight


kg/km
approx.
kg/km
276,0
1700,0
348,0
1800,0
435,0
2050,0
537,0
2150,0
696,0
2400,0
870,0
2700,0
1160,0
3200,0
1450,0
3555,0

AWG-No.
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil

Dimensions and specifications may be changed without prior notice. (RQ03)

Drag Chain Systems


Open chains
Closed chains
Accessories
Installation instructions
Selection tables

You can nd drag chain systems in our catalogue Cable Accessories.

Q 61
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

N2XSEY 3 x ... 6/10kV XLPE-insulated, Cu-conductor, PVC-jacket




Technical data

Cable structure

Properties

Three core XLPE-insulated power cables to


VDE0276 and IEC60502
Temperature range
during installation up to -5 C
Operating temperature
max. 90 C
Short circuit temperature
core 250 C
screen 350 C (duration)
(short circuit duration up to 5 sec.)
Nominal voltages U0/U 6/10 kV
Operating voltages
max. 12 kV
Test voltages 15 kV
Test voltages d.c. 48 kV
Power rating
to DINVDE0298 part2
Minimum bending radius
during installation 15x cable
Tests
according to
DINVDE0276 und IEC60502

Circular bare Cu-conductor of stranded


wires to DINVDE0295 cl.2 and IEC60228
cl.2
Inner semi-conducting coating
Core insulation of cross-linked Polyethylene
(XLPE), PE-compound DIX8 to HD620.1
Outer extrusion of semi-conducting
coating spliced with the XLPE-insulation
Conductive wrapping
Screen: Braiding of copper wires with one
or two tapes applied helically
3 cores stranded
Extruded sheath over three cores
PVC outer jacket, compound DMV6 to
HD405.1 and HD620/1
Jacket colour red

self-extinguishing and flame retardant


according to DINVDE0482 part265-2-1/
EN50265-2-1/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Installation notes
To guarantee an optimum on operating
reliability the extruded semi-conductive
layer is spliced with the insulation for long
duration. For this reason we recommend
a peeling tool for installation.


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
For laying in earth: For ground thermal
resistivity of 1K m/W, laying depth0,7m,
ground temperature20 C, EVU load
grade0,7.
For laying in air: Air temperature 30 C, EVU
load grade 1,0.
Conversion factors for laying in earth
especially for laying in bundle form and
other requirements are noted din
DINVDE0298 part2 and 0276 part1000.
Conversion factors for laying in air
Air temperature/Conversion factor
15 C/1,12; 20 C/1,08; 25 C/1,04; 30
C/1,0; 35 C/0,96; 35 C/0,96; 40 C/0,91;
45 C/0,87; 50 C/0,82;

Application
Suitable for installation in indoors and in cable ducts, outdoors as well as for laying on racks for industrial and switching systems and power
plants. Limited use when buried in the earth if the PVC outer jacket could be damaged by high mechanical stress.
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE
insulation assures a construction free of partial discharges with high operational reliability.



Part no.

34339
34340
34341
34342
34343
34344
34345
34346
34347
34348

No.cores x
cross-sec.
mm
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300

Insulation
thickness
mm
rm / 16
rm / 16
rm / 16
rm / 16
rm / 16
rm / 16
rm / 25
rm / 25
rm / 25
rm / 25

3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4

Screen
cross-sec.
mm
16
16
16
16
16
16
25
25
25
25

Jacket
thickness
Nominal value
mm
2,5
2,5
2,5
2,6
2,8
2,9
3
3,1
3,3
3,3

Outer
approx. mm
43,0
48,0
50,0
54,0
58,0
61,0
65,0
68,0
74,0
79,0

Cop.
weight
kg/km
1046,0
1210,0
1670,0
2250,0
2995,0
3715,0
4635,0
5645,0
7274,0
9160,0

Weight
AWG-No.
approx. kg/km
2850,0
3300,0
3750,0
4650,0
5700,0
6700,0
7900,0
9200,0
11450,0
14450,0

4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil

Dimensions and specifications may be changed without prior notice. (RQ03)

Q 62
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Large cabling machine with backtwist at our Windsbach factory

Photo: Helukabel

Q 63
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Data, Network and Bus Technology

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Data, Network and Bus Technology

R1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Data, Network and Bus Technology


The importance of information technology in our
communications-orientated world has increased
considerably in recent years. This can best be seen the
way distances between continents have diminished
because of the rapid processing of information
within media networks. Last but not least, the high
speed availability of information is of major signicance for industrial and commercial operations,
the economic success of these going hand in hand
with the availability of data. Well developed paths for
communications and infrastructures mean decisive
advantages in competition. Prerequisites for such
an exchange of information are the physical links
between the systems.
These are the cables for data and network engineering. HELUKABEL supplies the cables for infrastructures in local and wide-area networks. A whole range
of cables is available for standardised LANs of the
differing topologies, like Ethernet, Fast Ethernet,
Gigabit Ethernet, 10 Gigabit Ethernet, Token Ring,
FDDI and ATM.
Besides the basic level within such communication,
we also supply additional components such as the
cabinet systems, connection techniques for copper
and optical-bre cables, as well as other active components. The bus technology is becoming ever more
important in all elds of industrial applications. The
enormous pressures of competitiveness and costs in
all areas of process control emphasise the need for
even more rationalisation and greater efciency. The
traditional method of parallel wiring for the equipment and machines does not have the exibility and
thus constitutes a major factors in costs and time.
The use of bus systems opens up a very high potential for cost-saving. HELUKABEL supplies the appropriate cables for all common bus systems like ASI,
CAN, DeviceNet, EIB, INTERBUS, KH, PROFIBUS etc.

R2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents and Index


Description

Page

R HELUCOM Fibre optic cables


Fibre optic indoor cables.............................................................................................................................................................................R 6 R 9
Fibre optic cables.................................................................................................................................................................................... R 10 R 14
Fibre optic cable with functional integrity ............................................................................................................................................ R 15 R 16
Fibre optic outdoor cables ..................................................................................................................................................................... R 17 R 33
Fibre optic exible cables ....................................................................................................................................................................... R 34 R 37
Fibre optic outdoor cables, divisible .................................................................................................................................................................. R 38
Fibre optic industrial cables ................................................................................................................................................................... R 39 R 45
POF-Plastic bre cables .......................................................................................................................................................................... R 46 R 47

R HELUKAT Copper data cables


HELUKAT LAN cables .............................................................................................................................................................................. R 54 R 80
Multimedia cables ................................................................................................................................................................................... R 81 R 82
IBM-cabling ............................................................................................................................................................................................. R 83 R 85

R HELUKABEL Bus-Cables
Industrial Ethernet ................................................................................................................................................................................ R 89 R
Probus............................................................................................................................................................................................... R 107 R
FoundationTM Fieldbus ........................................................................................................................................................................ R 122 R
HMCB ................................................................................................................................................................................................... R 126 R
USB ...................................................................................................................................................................................................... R 130 R
CAN-Bus .............................................................................................................................................................................................. R 132 R
Interbus ............................................................................................................................................................................................... R 142 R
Multibus .............................................................................................................................................................................................. R 145 - R
A-Bus ................................................................................................................................................................................................... R 147 R
A-Bus, electrical cabinet ................................................................................................................................................................................... R
Sensor actuator ................................................................................................................................................................................................ R
Device-NetTM........................................................................................................................................................................................ R 153 R
CC-Link .............................................................................................................................................................................................................. R
Safety-Bus ......................................................................................................................................................................................................... R
LON-Bus............................................................................................................................................................................................................. R
EIB-Bus ................................................................................................................................................................................................ R 160 R
KH-Bus ............................................................................................................................................................................................................... R

106
121
125
129
131
141
144
146
150
151
152
156
157
158
159
162
163

R3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo:
Foto:HELUKABEL
HELUKABEL

Fiber Optic Cables HELUCOM

The future reliability of any installation depends on the correct choice of cable used in the network technique. It is only by careful
selection of the components that compliance with the continually increasing requirements placed upon the quality of the network
is possible. Infrastructures based on copper are continually nearing their physical limits because of the rapidly growing demands
from multimedia developments, and hence an alternative to copper must be provided for installations in the future.
The benets of optical bre technology are obvious: High transmission rates, low attenuation, no electromagnetic problems, small
dimensions and low weight. Modern designs for optical bre cables of the HELUCOM series exhibit the same robustness as a
copper cable. The cable constructions are selected for optimum protection of the optical bres in each application.
Within the HELUCOM series, optical bre cables are available with the common bre types of 50/125m, 62,5/125m, 9/125m,
200/230m and 980/1000m. The HELUCOM optical bre cables are manufactured in accordance with the standards and regulations
of DIN VDE 0888.

R4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents Fiber Optic Cables


Description
Fibre Optic Indoor Cable Composite buffered ............................................................ I-VH, I-V11Y, I-VHH, I-V11Y11Y
Fibre Optic Breakout-Cable Composite buffered ......................................................................................... I-V(ZN)HH
Fibre Optic Minibreakout Cable Tight buffer .................................................................................................. I-V(ZN)H
Fibre Optic Indoor Cable Loose tube .............................................................................................................. I-D(ZN)H
Fibre Optic Indoor/Outdoor Cable Tight buffer...................................................................................... A/I-VQ(ZN)BH
Fibre Optic Indoor/Outdoor Cable HELUCOM pact Loose tube ............................................................A/I-DQ(ZN)BH
Fibre Optic Indoor/Outdoor Cable HELUCOM pact Loose tube ................................................... A/I-DQ(ZN)BH OM3
Fibre Optic Indoor/Outdoor Cable Loose tube ......................................................................... A/I-DQ(ZN)BH, central
Fibre Optic Indoor/Outdoor Cable Loose tube ...................................................................... A/I-DQ(ZN)BH, stranded
Fibre Optic Cable with Functionality FS 30 with reference to DIN 4102-12 Loose tube ......................... A-DQ(ZN)BH
Fibre Optic Cable with Functionality FS 90 with reference to IEC 60331-25 Loose tube ................A/I-D(ZN)BH(SR)H
Fibre Optic Outdoor Cable Loose tube .........................................................................................A-DQ(ZN)2Y, central
Fibre Optic Outdoor Cable Loose tube ..................................................................................... A-DQ(ZN)2Y, stranded
Fibre Optic Outdoor Cable HELUCOM pact Loose tube.............................................................A-DQ(ZN)B2Y, central
Fibre Optic Outdoor Cable Loose tube .......................................................................................A-DQ(ZN)B2Y, central
Fibre Optic Outdoor Cable Loose tube ................................................................................... A-DQ(ZN)B2Y, stranded
Fibre Optic Outdoor Cable HELUCOM pact Loose tube.....................................A-DQ(ZN)B2Y Faserkombi, stranded
Fibre Optic Outdoor Cable Loose tube ...............................................................A-DQ(ZN)B2Y Faserkombi, stranded
Fibre Optic Outdoor Cable Loose tube ...................................................................................................... A-DF(ZN)2Y
Fibre Optic Outdoor Cable Loose tube .................................................................................................... A-DF(ZN)B2Y
Fibre Optic Outdoor Cable Loose tube .................................................................................................. A-DF(ZN)2Y4Y
Fibre Optic Outdoor Cable Microduct Loose tube .............................................................................. A-DQ2Y, central
Fibre Optic Outdoor Cable Microduct Loose tube ...........................................................................A-DQ2Y, stranded
Fibre Optic Outdoor Cable steel armoured Loose tube ......................................................................A-DQ(ZN)(SR)2Y
Fibre Optic Outdoor Cable acc. ARCOR Standard Loose tube ......................................................... A-DF(ZN)2Y(SR)2Y
Fibre Optic Outdoor Cable Hybrid Loose tube.......................................................................................A-DSQ(ZN)B2Y
Fibre Optic Outdoor Cable Hybrid Loose tube......................................................................................A-DSF(L)(ZN)2Y
Aerial Fibre Optic Cable metal free Loose tube ................................................................................................... ADSS
Fibre Optic Cable exible, WK-mobile Tight buffer ................................................................................... A-V(ZN)11Y
Fibre Optic Cable exible, WK-UL/CSA Tight buffer ....................................................................................... A-V(ZN)Y
Fibre Optic Cable exible, WK robust PUR + PVC (UL/CSA) Composite buffered .. AT-V(ZN)H(ZN)11Y, AT-V(ZN)Y(ZN)Y
Fibre Optic Cable exible, WK Composite buffered ................................................................................... AT-V(ZN)YY
Fibre Optic Breakout Cable, outdoor Composite buffered.............................................................AT-V(ZN)HH(BN)2Y
Fibre Optic Cable robust, multimode Tight buffer ............................................................................................AT-VYY
Fibre Optic Cable exible, HCS Composite buffered ..................................................................................I-VH, I-VHH
Fibre Optic Breakout Cable robust, exible, HCS Composite buffered ....................................................I-V(ZN)Y11Y
Fibre Optic Breakout Cable robust, HCS Composite buffered ............................................................ AT-VQH(ZN)B2Y
Fibre Optic Breakout Cable exible, HCS Composite buffered ................................................................. AT-V(ZN)HH
Fibre Optic Breakout Cable robust, exible, HCS UL/CSA Composite buffered ...........................................I-V(ZN)YY
Fibre-optic Universal Cable, HCS Loose tube ..........................................................................................A/I-DQ(ZN)BH
Plastic-bre cable industry, POF/PE POF 980/1000 .......................................................................I-V2Y, I-V2Y(ZN)11Y
Plastic-bre cable industry, POF/PA POF 980/1000 .................................................................................I-V4Y(ZN)11Y

Page
R6
R7
R8
R9
R 10
R 11
R 12
R 13
R 14
R 15
R 16
R 17
R 18
R 19
R 20
R 21
R 22
R 23
R 24
R 25
R 26
R 27
R 28
R 29
R 30
R 31
R 32
R 33
R 34
R 35
R 36
R 37
R 38
R 39
R 40
R 41
R 42
R 43
R 44
R 45
R 46
R 47

R5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Indoor Cable


acc. DIN VDE 0888

I-VH, I-V11Y, I-VHH, I-V11Y11Y

Cable structure

Temperature range

Other data

Core type: Composite buffered


Strain relief elements: Aramide
Outer sheath material: FRNC
Outer sheath colour: Yellow

Laying, min.: 0C
Laying, max.: +50C
Operating, min.: 0C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Flame-resistance acc. to IEC 60332-1
Smoke density acc. to IEC 61034

Designation

Number of Fibre type


fibres

Outer
Max.
approx. mm tensile
force N

I-VH
I-VH
I-VH
I-VH
I-VH
I-VH
I-V11Y
I-V11Y
I-V11Y
I-VHH
I-VHH
I-VHH
I-V11Y11Y
I-V11Y11Y
I-V11Y11Y

1
1
1
2
2
2
2
2
2
2
2
2
2
2
2

2,6
2,6
2,6
2,6 x 5,6
2,6 x 5,6
2,6 x 5,6
2,6 x 5,6
2,6 x 5,6
2,6 x 5,6
3,6 x 6,2
3,6 x 6,2
3,6 x 6,2
3,6 x 6,2
3,6 x 6,2
3,6 x 6,2

Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125

300
300
300
400
400
400
400
400
400
600
600
600
600
600
600

Min. stat.
Caloric load Max.
bending radius approx. MJ / transverse
mm
m
pressure
N / cm
40
0,17
10
40
0,17
10
40
0,17
10
40
0,24
10
40
0,24
10
40
0,24
10
40
2,80
20
40
2,80
20
40
2,80
20
50
0,57
20
50
0,57
20
50
0,57
20
60
4,20
20
60
4,20
20
60
4,20
20

Weight
kg / km
8,7
8,7
8,7
17,5
17,5
17,5
14,0
14,0
14,0
20,0
20,0
20,0
16,0
16,0
16,0

Part no.

80783
80782
80784
80316
80699
80785
82408
82410
82411
80789
80790
80791
82409
81900
82412

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM one-fibre and two-fibre (duplex) cables are used for fixed indoor installation, such as in cable ducts. These cables are also
used as ready-made cables (pigtails) that are spliced to fixed cables or as connection cables (jumper cable) as well as for switch frames. The
small diameter and the high flexibility make these cables ideal for the application in switch frames as well as for the connection of terminals.

R6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Breakout-Cable


acc. DIN VDE 0888

I-V(ZN)HH

Cable structure

Temperature range

Other data

Core type: Composite buffered


Strain relief elements: Aramide
Outer sheath material: FRNC
Outer sheath colour: Yellow

Laying, min.: 0C
Laying, max.: +50C
Operating, min.: 0C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Flame-resistance acc. to IEC 60332-1 and IEC
60332-3
Smoke density acc. to IEC 61034

Designation

I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH
I-V(ZN)HH

Number of Fibre type


fibres
2
2
2
4
4
4
6
6
6
8
8
8
12
12
12
16
16
16
24
24
24

Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125

Number of Outer
fibres per approx.
core
mm
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

7,1
7,1
7,1
7,1
7,1
7,1
8,4
8,4
8,4
9,3
9,3
9,3
9,6
9,6
9,6
15,0
15,0
15,0
17,5
17,5
17,5

Max.
tensile
force N
1000
1000
1000
1000
1000
1000
1350
1350
1350
1500
1500
1500
2350
2350
2350
2400
2400
2400
2400
2400
2400

Min. stat.
bending
radius
mm
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
270,0
330,0
330,0
320,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
1,00
300
1,00
300
1,00
300
1,00
300
1,00
300
1,00
300
1,25
300
1,25
300
1,25
300
1,50
300
1,50
300
1,50
300
1,85
300
1,85
300
1,85
300
2,40
300
2,40
300
2,40
300
3,20
300
3,20
300
3,20
300

Weight
kg / km
40,0
40,0
40,0
45,0
45,0
45,0
70,0
70,0
70,0
100,0
100,0
100,0
165,0
165,0
165,0
170,0
170,0
170,0
220,0
220,0
220,0

Part no.

80743
80799
80813
80753
80800
80814
80754
80769
80815
80688
80801
80816
80795
80803
80818
80796
80804
80819
80798
80806
80821

Dimensions and specifications may be changed without prior notice.

Application
HELUCOM breakout cables are designed to replace splicing on-site. They are mainly used in indoor applications for small and medium
transmission lines. The fibre-optic connectors are be mounted directly to the individual cables. Therefore no splicing and no splice boxes
are necessary. Pre-assembled cables only need to be laid on site and are immediately functional.

R7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Minibreakout Cable


acc. DIN VDE 0888

I-V(ZN)H

Cable structure

Temperature range

Other data

Core type: Tight buffer


Strain relief elements: Aramide
Outer sheath material: FRNC
Outer sheath colour: Orange

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -10C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Flame-resistance acc. to IEC 60332-1
Smoke density acc. to IEC 61034

Designation

I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H
I-V(ZN)H

Number of Fibre type


fibres
2
2
2
4
4
4
6
6
6
8
8
8
10
10
10
12
12
12

Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125

Number of Outer
fibres per approx.
core
mm
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

4,0
4,0
4,0
4,8
4,8
4,8
5,3
5,3
5,3
5,3
5,3
5,3
6,0
6,0
6,0
7,0
7,0
7,0

Max.
tensile
force N
400
400
400
400
400
400
400
400
400
500
500
500
600
600
600
800
800
800

Min. stat.
bending
radius
mm
60,0
60,0
60,0
70,0
70,0
70,0
80,0
80,0
80,0
80,0
80,0
80,0
90,0
90,0
90,0
110,0
110,0
110,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
0,24
40
0,24
40
0,24
40
0,31
40
0,31
40
0,31
40
0,35
40
0,35
40
0,35
40
0,40
40
0,40
40
0,40
40
0,53
40
0,53
40
0,53
40
0,61
40
0,61
40
0,61
40

Weight
kg / km
15,0
15,0
15,0
19,0
19,0
19,0
23,0
23,0
23,0
25,0
25,0
25,0
32,0
32,0
32,0
40,0
40,0
40,0

Part no.

80435
80434
80433
80432
80431
80430
80429
80428
80427
80426
80425
80424
80423
80422
80421
80420
80419
80418

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are used for the data network cabling in indoor applications. A big advantage of this cable type is its
space-saving construction. Similar to the breakout cable, the connector is directly mounted at the tight buffer.

R8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Indoor Cable


acc. DIN VDE 0888

I-D(ZN)H

Cable structure

Temperature range

Other data

Core type: Loose tube


Strain relief elements: Aramide
Outer sheath material: FRNC
Outer sheath colour: Yellow

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Flame-resistance acc. to IEC 60332-1
Smoke density acc. to IEC 61034

Designation

I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H
I-D(ZN)H

Number of Fibre type


fibres
4
4
4
6
6
6
8
8
8
10
10
10
12
12
12
16
16
16
24
24
24
24
24
24
36
36
36
48
48
48
60
60
60

Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G50/125
Multimode G62.5/125
Multimode G62.5/125
Single-mode E9/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125

Number of Outer
fibres per approx.
core
mm
4
4
4
6
6
6
8
8
8
10
10
10
12
12
12
16
16
16
12
24
12
24
12
24
12
12
12
12
12
12
12
12
12

8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
12,5
9,0
12,5
9,0
12,5
9,0
13,5
13,5
13,5
13,5
13,5
13,5
13,5
13,5
13,5

Max.
tensile
force N
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
3000
1600
3000
1600
3000
1600
3000
3000
3000
3000
3000
3000
3000
3000
3000

Min. stat.
bending
radius
mm
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
120,0
190,0
140,0
190,0
140,0
190,0
140,0
200,0
200,0
200,0
200,0
200,0
200,0
200,0
200,0
200,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
1,50
150
1,50
150
1,50
150
1,50
150
1,50
150
1,50
150
1,50
150
1,50
150
1,50
150
1,50
150
1,50
150
1,50
150
1,50
150
1,50
150
1,50
150
1,50
150
1,50
150
1,50
150
2,20
200
1,50
150
2,20
200
1,50
150
2,20
200
1,50
150
2,20
200
2,20
200
2,20
200
2,20
200
2,20
200
2,20
200
2,20
200
2,20
200
2,20
200

Weight
kg / km
65,0
65,0
65,0
65,0
65,0
65,0
65,0
65,0
65,0
65,0
65,0
65,0
65,0
65,0
65,0
135,0
135,0
135,0
150,0
135,0
150,0
135,0
150,0
135,0
160,0
160,0
160,0
160,0
160,0
160,0
170,0
170,0
170,0

Part no.

80631
80882
80896
80868
80883
80897
80869
80884
80898
80793
80885
80899
80045
80879
80880
80870
80886
80900
80872
80871
80888
81246
80902
80901
80875
80891
80905
80877
80893
80907
80878
80894
80908

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are available either as central bundle core cable or as stranded versions. They are suitable for indoor
cabling of buildings and facilities. The halogen-free version is especially suitable for the application in skyscrapers, hospitals and stores as
well as in facilities with high concentration of capital goods, such as power plants, computing centers, and at locations with high security
requirements, such as underground and control stations.

R9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Indoor/Outdoor Cable


acc. DIN VDE 0888

A/I-VQ(ZN)BH

Cable structure

Temperature range

Other data

Core type: Tight buffer


Strain relief elements: Aramide
Type of armouring: Glass yarns
Outer sheath material: FRNC
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +55C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Flame-resistance acc. to IEC 60332-1
Smoke density acc. to IEC 61034
UV-resistant

Designation

A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH
A/I-VQ(ZN)BH

Number of Fibre type


fibres
4
4
4
6
6
6
8
8
8
10
10
10
12
12
12

Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125

Number of Outer
fibres per approx.
core
mm
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

6,1
6,1
6,1
6,6
6,6
6,6
6,6
6,6
6,6
8,0
8,0
8,0
8,3
8,3
8,3

Max.
tensile
force N
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
3000
3000
3000

Min. stat.
bending
radius
mm
90,0
90,0
90,0
100,0
100,0
100,0
100,0
100,0
100,0
120,0
120,0
120,0
125,0
125,0
125,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
0,35
40
0,35
40
0,35
40
0,41
40
0,41
40
0,41
40
0,43
40
0,43
40
0,43
40
0,61
40
0,61
40
0,61
40
0,71
40
0,71
40
0,71
40

Weight
kg / km
40,0
40,0
40,0
47,0
47,0
47,0
51,0
51,0
51,0
65,0
65,0
65,0
70,0
70,0
70,0

Part no.

82804
82809
82814
82805
82810
82815
82806
82811
82816
82807
82812
82817
82808
82813
82818

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are used for the data network cabling in indoor and outdoor applications. With their black UV-resistant
outer sheath and the non-metallic rodent protection, they are perfectly suited for outdoor use. A big advantage of this cable type is its
space-saving construction. Similar to the breakout cable, the connector is directly mounted at the tight buffer.

R 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Indoor/Outdoor


Cable

pact

acc. DIN VDE 0888

A/I-DQ(ZN)BH

Cable structure

Temperature range

Other data

Core type: Loose tube


Strain relief elements: Glass yarns
Type of armouring: Glass yarns
Outer sheath material: FRNC
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Flame-resistance acc. to IEC 60332-1
Smoke density acc. to IEC 61034
Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant

Designation

A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH

Number of Fibre type


fibres
4
4
4
6
6
6
8
8
8
12
12
12
24
24
24

Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125

Number of Outer
fibres per approx.
core
mm
4
4
4
6
6
6
8
8
8
12
12
12
24
24
24

7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
8,5
8,5
8,5

Max.
tensile
force N
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500

Min. stat.
bending
radius
mm
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
170,0
170,0
170,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
1,10
200
1,10
200
1,10
200
1,10
200
1,10
200
1,10
200
1,10
200
1,10
200
1,10
200
1,10
200
1,10
200
1,10
200
1,40
200
1,40
200
1,40
200

Weight
kg / km

Part no.

55,0
55,0
55,0
55,0
55,0
55,0
55,0
55,0
55,0
55,0
55,0
55,0
75,0
75,0
75,0

82792
82796
82800
82793
82797
82801
82794
82798
82802
82795
82799
82803
802143
802144
802145

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM pact fibre-optic cables have a small but robust construction. They are suitable for indoor and outdoor cabling of buildings
and facilities when space is an important argument. They are used in particular if the installation is to be done in one piece from the inside
to the outside without additional use of couplings. With their black UV-resistant outer sheath and the non-metallic rodent protection, they
are perfectly suited for outdoor use. The halogen-free outer sheath makes installation inhouse possible without any problems.

R 11
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Indoor/Outdoor


Cable
acc. DIN VDE 0888

pact
A/I-DQ(ZN)BH OM3

Cable structure

Temperature range

Other data

Core type: Loose tube


Strain relief elements: Glass yarns
Type of armouring: Glass yarns
Outer sheath material: FRNC
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Flame-resistance acc. to IEC 60332-1
Smoke density acc. to IEC 61034
Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant

Designation

A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH

Number of Fibre type


fibres
4
6
8
12
24

Multimode G50/125
Multimode G50/125
Multimode G50/125
Multimode G50/125
Multimode G50/125

Number of Outer
fibres per approx.
core
mm
4
6
8
12
24

7,5
7,5
7,5
7,5
8,5

Max.
tensile
force N
1500
1500
1500
1500
1500

Min. stat.
bending
radius
mm
150,0
150,0
150,0
150,0
170,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
1,10
200
1,10
200
1,10
200
1,10
200
1,40
200

Weight
kg / km

Part no.

55,0
55,0
55,0
55,0
75,0

802247
802277
802278
802248
802249

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM pact fibre-optic cables have a small but robust construction. They are suitable for indoor and outdoor cabling of buildings
and facilities when space is an important argument. They are used in particular if the installation is to be done in one piece from the inside
to the outside without additional use of couplings. With their black UV-resistant outer sheath and the non-metallic rodent protection, they
are perfectly suited for outdoor use. The halogen-free outer sheath makes installation inhouse possible without any problems.

R 12
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Indoor/Outdoor Cable


acc. DIN VDE 0888

A/I-DQ(ZN)BH, central

Cable structure

Temperature range

Other data

Core type: Loose tube


Strain relief elements: Glass yarns
Type of armouring: Glass yarns
Outer sheath material: FRNC
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Flame-resistance acc. to IEC 60332-1
Smoke density acc. to IEC 61034
Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant

Designation

A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH

Number of Fibre type


fibres
4
4
4
6
6
6
8
8
8
12
12
12
16
16
16
24
24

Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125

Number of Outer
fibres per approx.
core
mm
4
4
4
6
6
6
8
8
8
12
12
12
16
16
16
24
24

10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0

Max.
tensile
force N
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500

Min. stat.
bending
radius
mm
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
1,50
300
1,50
300
1,50
300
1,50
300
1,50
300
1,50
300
1,50
300
1,50
300
1,50
300
1,50
300
1,50
300
1,50
300
1,50
300
1,50
300
1,50
300
1,50
300
1,50
300

Weight
kg / km
125,0
125,0
125,0
125,0
125,0
125,0
125,0
125,0
125,0
125,0
125,0
125,0
145,0
145,0
145,0
145,0
145,0

Part no.

80270
80276
80264
80271
80265
80272
80273
80274
80275
80681
80278
80279
80280
80281
80851
80725
82431

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are available either as central bundle core cable or as stranded versions. They are suitable for indoor and
outdoor cabling of buildings and facilities. They are used in particular if the installation is to be done in one piece from the inside to the
outside without additional use of couplings. With their black UV-resistant outer sheath and the non-metallic rodent protection, they are
perfectly suited for outdoor use. The halogen-free outer sheath makes installation inhouse possible without any problems.

R 13
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Indoor/Outdoor Cable


acc. DIN VDE 0888

A/I-DQ(ZN)BH, stranded

Cable structure

Temperature range

Other data

Core type: Loose tube


GRP support element
Strain relief elements: Glass yarns
Type of armouring: Glass yarns
Outer sheath material: FRNC
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Flame-resistance acc. to IEC 60332-1
Smoke density acc. to IEC 61034
Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant

Designation

A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH

Number of Fibre type


fibres
24
24
24
48
48
48
48
60
60
60
72
72
72
84
84
84
96
96
96

Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125

Number of Outer
fibres per approx.
core
mm
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

11,0
11,0
11,0
11,0
11,0
11,0
11,0
11,0
11,0
11,0
11,5
11,5
11,5
12,5
12,5
12,5
12,5
12,5
12,5

Max.
tensile
force N
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
3000
3000
3000
3000
3000
3000

Min. stat.
bending
radius
mm
165,0
165,0
165,0
165,0
165,0
165,0
165,0
165,0
165,0
165,0
175,0
175,0
175,0
190,0
190,0
190,0
190,0
190,0
190,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
2,00
600
2,00
600
2,00
600
2,00
600
2,00
600
2,00
600
2,00
600
2,00
600
2,00
600
2,00
600
2,10
600
2,10
600
2,10
600
2,40
600
2,40
600
2,40
600
2,80
600
2,80
600
2,80
600

Weight
kg / km

Part no.

90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
100,0
100,0
100,0
130,0
130,0
130,0
130,0
130,0
130,0

81495
802263
80846
802261
802264
802266
802281
802262
802265
802267
802268
802271
802274
802269
802272
802275
802270
802273
802276

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are available either as central bundle core cable or as stranded versions. They are suitable for indoor and
outdoor cabling of buildings and facilities. They are used in particular if the installation is to be done in one piece from the inside to the
outside without additional use of couplings. With their black UV-resistant outer sheath and the non-metallic rodent protection, they are
perfectly suited for outdoor use. The halogen-free outer sheath makes installation inhouse possible without any problems.

R 14
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Cable with


Functionality

FS30

with reference to DIN 4102-12

A-DQ(ZN)BH

Cable structure

Temperature range

Other data

Core type: Loose tube


Strain relief elements: Aramide
Type of armouring: Glass yarns
Outer sheath material: FR/LSOH
Outer sheath colour: Red

Laying, min.: -10C


Laying, max.: +50C
Operating, min.: -25C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Flame-resistance acc. to IEC 60332-1
Smoke density acc. to IEC 61034
Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant
Functional integrity: E30

Designation

A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH

Number of Fibre type


fibres
4
4
4
12
12
12

Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125

Number of Outer
fibres per approx.
core
mm
4
4
4
12
12
12

7,8
7,8
7,8
7,8
7,8
7,8

Max.
tensile
force N
1000
1000
1000
1000
1000
1000

Min. stat.
bending
radius
mm
80,0
80,0
80,0
80,0
80,0
80,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
1,08
200
1,08
200
1,08
200
1,08
200
1,08
200
1,08
200

Weight
kg / km

Part no.

102,0
102,0
102,0
102,0
102,0
102,0

801217
801218
801219
801220
801221
801190

Dimensions and specifications may be changed without prior notice.

Application
With the serie HELUCOM E30 we have realized, based on a special construction and high quality raw materials, a functional Integrity according
to DIN 4102-12 E30 (30 minutes). Together with the planed accessories the cables realize the full function of the communication in areas
like tunnels or buildings for the defined period of time. On request we also can deliver cables with more than 12 fibres as stranded construction.

R 15
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Cable with


Functionality

FS90

with reference to IEC 60331-25

A/I-D(ZN)BH(SR)H

Cable structure

Temperature range

Other data

Core type: Loose tube


Strain relief elements: Glass yarns
Inner sheath material: FRNC
Type of armouring: steel tape
Outer sheath material: FR/LSOH
Outer sheath colour: Yellow

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +70C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Flame-resistance acc. to IEC 60332-1 and -3
Smoke density acc. to IEC 61034
Longitudinally water-tight acc. to IEC
60794-1-2-F5
Cable, laterally water-tight
Functional integrity: IEC 60794/ IEC 60331-25

Designation

A/I-D(ZN)BH(SR)H
A/I-D(ZN)BH(SR)H
A/I-D(ZN)BH(SR)H
A/I-D(ZN)BH(SR)H

Number of Fibre type


fibres
4
4
12
12

Multimode G50/125
Single-mode E9/125
Multimode G50/125
Single-mode E9/125

Number of Outer
fibres per approx.
core
mm
4
4
12
12

12,7
12,7
12,7
12,7

Max.
tensile
force N
700
700
700
700

Min. stat.
bending
radius
mm
180,0
180,0
180,0
180,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
6,20
300
6,20
300
6,20
300
6,20
300

Weight
kg / km

Part no.

216,0
216,0
216,0
216,0

803917
803919
803918
803920

Dimensions and specifications may be changed without prior notice.

Application
With the serie HELUCOM FS90 we have realized, based on a special construction and high quality raw materials, a functional Integrity according
to IEC 60331-25 within 90, minutes (up to 750 C). Together with the planed accessories the cables realize the full function of the communication
in areas like tunnels or buildings for the defined period of time. On request we also can deliver cables with more than 12 fibres as stranded
construction.

R 16
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Outdoor Cable


acc. DIN VDE 0888

A-DQ(ZN)2Y, central

Cable structure

Temperature range

Other data

Core type: Loose tube


Strain relief elements: Glass yarns
Outer sheath material: PE
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant

Designation

A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y

Number of Fibre type


fibres
2
2
2
4
4
4
6
6
6
8
8
8
12
12
12
16
16
16
24
24
24

Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125

Number of Outer
fibres per approx.
core
mm
2
2
2
4
4
4
6
6
6
8
8
8
12
12
12
16
16
16
24
24
24

8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8

Max.
tensile
force N
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500

Min. stat.
bending
radius
mm
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0
130,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
1,60
250
1,60
250
1,60
250
1,60
250
1,60
250
1,60
250
1,60
250
1,60
250
1,60
250
1,60
250
1,60
250
1,60
250
1,60
250
1,60
250
1,60
250
1,80
250
1,80
250
1,80
250
1,80
250
1,80
250
1,80
250

Weight
kg / km
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
70,0
70,0
70,0
70,0
70,0
70,0

Part no.

80148
80164
80131
80149
80165
80132
80150
80166
80133
80151
80167
80134
80153
80169
80136
80154
80170
80137
80155
80171
80138

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are characterized by a design that is particularly easy to mount. Around a central grooved cable, there
is a composite of glass yarns and swelling fleece with characteristics that ensure the actual strain relief and waterproofing in longitudinal
direction of the cable. In addition, these cables are designed grease-free. Wiping the jelly off is therefore unnecessary. This construction is
particularly used in underground, tubes and channel areas, where rodent infestation is not to be expected.

R 17
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Outdoor Cable


acc. DIN VDE 0888

A-DQ(ZN)2Y, stranded

Cable structure

Temperature range

Other data

Core type: Loose tube


GRP support element
Strain relief elements: Glass yarns
Outer sheath material: PE
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant

Designation

A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y

Number of Fibre type


fibres
24
24
24
36
36
36
48
48
48
60
60
60
72
72
72
84
84
84
96
96
96
108
108
108
120
120
120
144
144
144

Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125

Number of Outer
fibres per approx.
core
mm
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,5
10,5
10,5
11,5
11,5
11,5
11,5
11,5
11,5
13,0
13,0
13,0
13,0
13,0
13,0
14,0
14,0
14,0

Max.
tensile
force N
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700

Min. stat.
bending
radius
mm
200,0
200,0
200,0
200,0
200,0
200,0
200,0
200,0
200,0
200,0
200,0
200,0
210,0
210,0
210,0
230,0
230,0
230,0
230,0
230,0
230,0
260,0
260,0
260,0
260,0
260,0
260,0
280,0
280,0
280,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
2,50
400
2,50
400
2,50
400
2,50
400
2,50
400
2,50
400
2,50
400
2,50
400
2,50
400
2,50
400
2,50
400
2,50
400
2,60
400
2,60
400
2,60
400
3,30
400
3,30
400
3,30
400
3,30
400
3,30
400
3,30
400
4,00
400
4,00
400
4,00
400
4,00
400
4,00
400
4,00
400
5,00
400
5,00
400
5,00
400

Weight
kg / km
70,0
70,0
70,0
70,0
70,0
70,0
70,0
70,0
70,0
70,0
70,0
70,0
75,0
75,0
75,0
110,0
110,0
110,0
110,0
110,0
110,0
130,0
130,0
130,0
130,0
130,0
130,0
150,0
150,0
150,0

Part no.

80156
80172
80139
80448
80449
80450
80447
80446
80445
80159
80175
80142
80444
80443
80442
80160
80176
80143
80441
80440
80439
80161
80177
80144
80162
80178
80146
80438
80437
80436

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are characterized by a design that is particularly easy to mount and extremely tension-resistant. Around
a stranded grooved cable and filler elements, there is a swelling fleece with characteristics that ensure strain relief and waterproofing in
longitudinal direction of the cable. In addition, these cables are designed grease-free. Wiping the jelly off is therefore unnecessary. This
construction is particularly used in underground, tubes and channel areas, where above-average tensile stresses and/or transverse compressions
occur, but rodent infestation is not to be expected.

R 18
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Outdoor Cable

pact

acc. DIN VDE 0888

A-DQ(ZN)B2Y, central

Cable structure

Temperature range

Other data

Core type: Loose tube


Strain relief elements: Glass yarns
Type of armouring: Glass yarns
Outer sheath material: PE
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant

Designation

A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y

Number of Fibre type


fibres
2
2
2
4
4
4
6
6
6
8
8
8
12
12
12
24
24
24

Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125

Number of Outer
fibres per approx.
core
mm
2
2
2
4
4
4
6
6
6
8
8
8
12
12
12
24
24
24

7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
8,5
8,5
8,5

Max.
tensile
force N
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500

Min. stat.
bending
radius
mm
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
150,0
170,0
170,0
170,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,90
300
1,90
300
1,90
300

Weight
kg / km

Part no.

40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
40,0
60,0
60,0
60,0

800754
802131
802137
800755
802132
802138
800756
802133
802139
800757
802134
802140
800759
802135
802141
802142
800762
802136

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM pact fibre-optic cables are characterized by a design that is particularly easy to mount and is rodent-protected. Around a
central grooved cable, there is a composite of glass yarns and swelling fleece with characteristics that ensure rodent protection, strain relief,
and waterproofing in longitudinal direction of the cable. In addition, these cables are designed grease-free. Wiping the jelly off is therefore
unnecessary. This construction is particularly used in underground, tubes and channel areas, where normal tensile stresses and/or transverse
compressions occur and rodent infestation is to be expected.

R 19
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Outdoor Cable


acc. DIN VDE 0888

A-DQ(ZN)B2Y, central

Cable structure

Temperature range

Other data

Core type: Loose tube


Strain relief elements: Glass yarns
Type of armouring: Glass yarns
Outer sheath material: PE
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant

Designation

A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y

Number of Fibre type


fibres
2
2
2
4
4
4
6
6
6
8
8
8
12
12
12
16
16
16
24
24
24

Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125

Number of Outer
fibres per approx.
core
mm
2
2
2
4
4
4
6
6
6
8
8
8
12
12
12
16
16
16
24
24
24

10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0

Max.
tensile
force N
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500

Min. stat.
bending
radius
mm
160,0
160,0
160,0
160,0
160,0
160,0
160,0
160,0
160,0
160,0
160,0
160,0
160,0
160,0
160,0
180,0
180,0
180,0
180,0
180,0
180,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,60
300
1,80
300
1,80
300
1,80
300
1,80
300
1,80
300
1,80
300

Weight
kg / km
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
130,0
130,0
130,0
130,0
130,0
130,0

Part no.

80196
80212
80180
80197
80213
80181
80198
80214
80182
80199
80215
80183
80201
80217
80185
80202
80218
80186
80204
80220
80187

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are characterized by a design that is particularly easy to mount and is rodent-protected. Around a central
grooved cable, there is a composite of glass yarns and swelling fleece with characteristics that ensure rodent protection, strain relief, and
waterproofing in longitudinal direction of the cable. In addition, these cables are designed grease-free. Wiping the jelly off is therefore
unnecessary. This construction is particularly used in underground, tubes and channel areas, where normal tensile stresses and/or transverse
compressions occur and rodent infestation is to be expected.

R 20
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Outdoor Cable


acc. DIN VDE 0888

A-DQ(ZN)B2Y, stranded

Cable structure

Temperature range

Other data

Core type: Loose tube


GRP support element
Strain relief elements: Glass yarns
Type of armouring: Glass yarns
Outer sheath material: PE
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant

Designation

A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y

Number of Fibre type


fibres
24
24
24
36
36
36
48
48
48
60
60
60
72
72
72
84
84
84
96
96
96
108
108
108
120
120
120
144
144
144

Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125

Number of Outer
fibres per approx.
core
mm
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
11,0
11,0
11,0
12,0
12,0
12,0
12,0
12,0
12,0
13,5
13,5
13,5
13,5
13,5
13,5
14,5
14,5
14,5

Max.
tensile
force N
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000

Min. stat.
bending
radius
mm
210,0
210,0
210,0
210,0
210,0
210,0
210,0
210,0
210,0
210,0
210,0
210,0
220,0
220,0
220,0
240,0
240,0
240,0
240,0
240,0
240,0
270,0
270,0
270,0
270,0
270,0
270,0
290,0
290,0
290,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
2,70
600
2,70
600
2,70
600
2,70
600
2,70
600
2,70
600
2,70
600
2,70
600
2,70
600
2,70
600
2,70
600
2,70
600
2,90
600
2,90
600
2,90
600
3,60
600
3,60
600
3,60
600
3,60
600
3,60
600
3,60
600
4,30
600
4,30
600
4,30
600
4,30
600
4,30
600
4,30
600
5,40
600
5,40
600
5,40
600

Weight
kg / km
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
100,0
100,0
100,0
140,0
140,0
140,0
140,0
140,0
140,0
155,0
155,0
155,0
155,0
155,0
155,0
200,0
200,0
200,0

Part no.

81382
80219
80188
81108
81109
81110
82648
81112
81113
80207
80223
80191
81133
81134
81120
80208
80224
80192
81135
81136
81121
80209
80225
80193
80210
80226
80194
80211
80227
80195

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are characterized by a design that is particularly easy to mount, extremely tension-resistant and
rodent-proof. Around a stranded grooved cable and filler elements, there is a composite of glass yarns and swelling fleece with characteristics
that ensure rodent protection, strain relief, and waterproofing in longitudinal direction of the cable. In addition, these cables are designed
grease-free. Wiping the jelly off is therefore unnecessary. This construction is particularly used in underground, tubes and channel areas,
where above-average tensile stresses and/or transverse compressions occur and rodent infestation is to be expected.

R 21
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Outdoor Cable


acc. DIN VDE 0888

pact
A-DQ(ZN)B2Y fibre combi, stranded

Cable structure

Temperature range

Other data

Core type: Loose tube


GRP support element
Strain relief elements: Glass yarns
Type of armouring: Glass yarns
Outer sheath material: PE
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant

Designation

Number of Fibre type


fibres

A-DQ(ZN)B2Y

24

A-DQ(ZN)B2Y

24

A-DQ(ZN)B2Y

48

A-DQ(ZN)B2Y

48

Single- and multimode


G50/125
Single- und Multimode
G50/125 OM3
Single- and multimode
G50/125
Single- und Multimode
G50/125 OM3

Number of Outer
fibres per approx.
core
mm

Max.
tensile
force N

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
2,50
400

Weight
kg / km

Part no.

90,0

803037

12

9,5

2500

Min. stat.
bending
radius
mm
200,0

12

9,5

2500

200,0

2,50

400

90,0

803923

12

9,5

2500

200,0

2,50

400

90,0

803038

12

9,5

2500

200,0

2,50

400

90,0

803924

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM pact fibre-optic cables are characterized by a design that is particularly easy to mount, tension-resistant and rodent-proof.
Around a stranded grooved cable and filler elements, there is a composite of glass yarns and swelling fleece with characteristics that ensure
rodent protection, strain relief and waterproofing in longitudinal direction of the cable. In addition, these cables are designed grease-free.
Wiping the jelly off is therefore unnecessary. This construction is particularly used in underground, tubes and channel areas, where packing
density also plays a role.

R 22
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Outdoor Cable


acc. DIN VDE 0888

A-DQ(ZN)B2Y fibre combi, stranded

Cable structure

Temperature range

Other data

Core type: Loose tube


GRP support element
Strain relief elements: Glass yarns
Type of armouring: Glass yarns
Outer sheath material: PE
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant

Designation

Number of Fibre type


fibres

A-DQ(ZN)B2Y

24

A-DQ(ZN)B2Y

48

Single- and multimode


G50/125
Single- and multimode
G50/125

Number of Outer
fibres per approx.
core
mm

Max.
tensile
force N

12

10,5

2700

Min. stat.
bending
radius
mm
200,0

12

10,5

2700

200,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
2,70
600
2,70

600

Weight
kg / km

Part no.

95,0

81478

95,0

801183

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are characterized by a design that is particularly easy to mount, extremely tension-resistant and
rodent-proof. Around a stranded grooved cable and filler elements, there is a composite of glass yarns and swelling fleece with characteristics
that ensure rodent protection, strain relief and waterproofing in longitudinal direction of the cable. In addition, these cables are designed
grease-free. Wiping the jelly off is therefore unnecessary. This construction is particularly used in underground, tubes and channel areas,
where above-average tensile stresses and/or transverse compressions occur and rodent infestation is to be expected.

R 23
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Outdoor Cable


acc. DIN VDE 0888

A-DF(ZN)2Y

Cable structure

Temperature range

Other data

Core type: Loose tube


GRP support element
Strain relief elements: Aramide
Outer sheath material: PE
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant

Designation

A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y

Number of Fibre type


fibres
2
2
2
4
4
4
8
8
8
12
12
12
24
24
24
36
36
36
48
48
48
60
60
60
72
72
72
84
84
84
96
96
96
144
144
144

Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125

Number of Outer
fibres per approx.
core
mm
2
2
2
4
4
4
8
8
8
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
10,0
10,0
10,0
10,7
10,7
10,7
11,5
11,5
11,5
14,5
14,5
14,5

Max.
tensile
force N
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
3000
3000
3000
3000
3000
3000
3000
3000
3000

Min. stat.
bending
radius
mm
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
95,0
100,0
100,0
100,0
107,0
107,0
107,0
115,0
115,0
115,0
145,0
145,0
145,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
4,20
400
4,20
400
4,20
400
4,20
400
4,20
400
4,20
400
4,20
400
4,20
400
4,20
400
4,20
400
4,20
400
4,20
400
4,00
400
4,00
400
4,00
400
4,00
400
4,00
400
4,00
400
4,00
400
4,00
400
4,00
400
4,00
400
4,00
400
4,00
400
3,80
400
3,80
400
3,80
400
4,30
400
4,30
400
4,30
400
5,00
400
5,00
400
5,00
400
7,70
400
7,70
400
7,70
400

Weight
kg / km
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
85,0
90,0
90,0
90,0
120,0
120,0
120,0
135,0
135,0
135,0
175,0
175,0
175,0

Part no.

80016
80033
80000
80017
80034
80001
80019
80036
80003
80021
80038
80005
80024
80041
80008
80912
80913
80914
80026
80046
80010
80027
80047
80011
80473
80474
80475
80028
80048
80012
80777
80774
80764
80032
80051
80015

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are characterized by a stranded construction with jelly filling. They are made waterproof in longitudinal
direction by filling a jelly mass into the stranding cavities. Non-metallic tension elements ensure above average strain relief. This construction
is particularly used in the area of telecommunication and long distance, but also in regular channels and tubes.

R 24
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Outdoor Cable


acc. DIN VDE 0888

A-DF(ZN)B2Y

Cable structure

Temperature range

Other data

Core type: Loose tube


GRP support element
Strain relief elements: Aramide
Type of armouring: Glass yarns
Outer sheath material: PE
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant

Designation

A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y
A-DF(ZN)B2Y

Number of Fibre type


fibres
2
2
2
4
4
4
8
8
8
12
12
12
24
24
24
36
36
36
48
48
48
60
60
60
72
72
72
84
84
84
96
96
96
144
144
144

Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125

Number of Outer
fibres per approx.
core
mm
2
2
2
4
4
4
8
8
8
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10,5
11,0
11,0
11,0
11,5
11,5
11,5
12,0
12,0
12,0
14,5
14,5
14,5

Max.
tensile
force N
2500
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
3000
3000
3000
3000
3000
3000
3000
3000
3000

Min. stat.
bending
radius
mm
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
105,0
110,0
110,0
110,0
115,0
115,0
115,0
120,0
120,0
120,0
145,0
145,0
145,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
4,40
400
4,40
400
4,40
400
4,40
400
4,40
400
4,40
400
4,40
400
4,40
400
4,40
400
4,40
400
4,40
400
4,40
400
4,40
400
4,40
400
4,40
400
4,30
400
4,30
400
4,30
400
4,20
400
4,20
400
4,20
400
4,20
400
4,20
400
4,20
400
4,10
400
4,10
400
4,10
400
4,60
400
4,60
400
4,60
400
5,30
400
5,30
400
5,30
400
8,00
400
8,00
400
8,00
400

Weight
kg / km
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
95,0
95,0
95,0
136,0
136,0
136,0
155,0
155,0
155,0
228,0
228,0
228,0

Part no.

80100
80115
80084
80101
80116
80085
80031
80771
80087
80104
80120
80089
80759
80123
80092
81137
81138
81139
80109
80125
80094
80110
80126
80095
81143
81144
81145
80111
80127
80096
81147
81148
81149
80114
80130
80099

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are characterized by a stranded construction with jelly filling. They are made waterproof in longitudinal
direction by filling a jelly mass into the stranding cavities. Non-metallic tension elements and glass yarns ensure above average strain relief
and rodent protection. This construction is particularly used in the area of telecommunication and long distance, but also in regular channels
and tubes where rodent infestation is possible.

R 25
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Outdoor Cable


acc. DIN VDE 0888

A-DF(ZN)2Y4Y

Cable structure

Temperature range

Other data

Core type: Loose tube


GRP support element
Strain relief elements: Aramide
Inner sheath material: PE
Type of armouring: PA sheath
Outer sheath material: PA
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Longitudinally water-tight acc. to IEC
60794-1-2-F5
Cable, laterally water-tight
UV-resistant

Designation

A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y

Number of Fibre type


fibres
2
2
2
4
4
4
8
8
8
12
12
12
24
24
24
36
36
36
48
48
48
60
60
72
72
72
84
84
84
96
96
96
144
144
144

Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125

Number of Outer
fibres per approx.
core
mm
2
2
2
4
4
4
8
8
8
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
10,5
10,5
10,5
11,0
11,0
11,0
11,5
11,5
11,5
14,5
14,5
14,5

Max.
tensile
force N
2500
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
2700
3000
3000
3000
3000
3000
3000
3000
3000
3000

Min. stat.
bending
radius
mm
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
105,0
105,0
105,0
110,0
110,0
110,0
115,0
115,0
115,0
145,0
145,0
145,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
6,10
400
6,10
400
6,10
400
6,10
400
6,10
400
6,10
400
6,10
400
6,10
400
6,10
400
6,10
400
6,10
400
6,10
400
6,10
400
6,10
400
6,10
400
6,00
400
6,00
400
6,00
400
6,00
400
6,00
400
6,00
400
5,80
400
5,80
400
5,80
400
5,80
400
5,80
400
8,40
400
8,40
400
8,40
400
7,20
400
7,20
400
7,20
400
10,40
400
10,40
400
10,40
400

Weight
kg / km
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
90,0
95,0
95,0
95,0
110,0
110,0
110,0
120,0
120,0
120,0
180,0
180,0
180,0

Part no.

80915
80927
80945
80735
80928
80895
80691
80809
80118
80627
80931
80947
80578
80576
80577
80672
80935
80950
80732
80936
80951
80920
80938
80921
80939
80954
80922
80940
80955
80923
80941
80956
80926
80944
80959

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are characterized by a stranded construction with jelly filling. They are made waterproof in longitudinal
direction by filling a jelly mass into the stranding cavities. Non-metallic tension elements and a second outer sheath made of polyamide (PA)
ensure above average strain relief and rodent protection. This construction is particularly used in the area of telecommunication and long
distance, but also in regular channels and tubes where rodent infestation is possible.

R 26
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Outdoor Cable


Microduct

A-DQ2Y, central

Cable structure

Temperature range

Other data

Core type: Loose tube


Outer sheath material: PE
Outer sheath colour: Black

Laying, min.: -20C


Laying, max.: +60C
Operating, min.: -20C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant

Designation

A-DQ2Y central
A-DQ2Y central

Number of Fibre type


fibres
4
12

Single-mode E9/125
Single-mode E9/125

Number of Outer
fibres per approx.
core
mm
4
12

2,5
2,5

Max.
tensile
force N
180
180

Min. stat.
bending
radius
mm
25,0
25,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
1,40
200
1,40
200

Weight
kg / km
6,0
6,0

Part no.

803664
803929

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM micro fibre-optic cables are characterized by a design that is slim but robust. Around a central tube, there is a composite
of swelling fleece with characteristics that ensure the strain relief, and waterproofing in longitudinal direction of the cable. This construction
is particularly used in tubes and channels. These cables can be blowing into microducts.

R 27
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Outdoor Cable


Microduct

A-DQ2Y, stranded

Cable structure

Temperature range

Other data

Core type: Loose tube


GRP support element
Outer sheath material: PE
Outer sheath colour: Black

Laying, min.: -30C


Laying, max.: +60C
Operating, min.: -30C
Operating, max.: +70C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant

Designation

Number of Fibre type


fibres

A-DQ2Y stranded
4
A-DQ2Y stranded
12
A-DQ2Y stranded
24
A-DQ2Y stranded
48
A-DQ2Y stranded
72
A-DQ2Y stranded
96
A-DQ2Y stranded 144
A-DQ2Y stranded 288

Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125

Number of Outer
fibres per approx.
core
mm
4
12
12
12
12
12
12
12

6,0
6,0
6,0
6,0
6,0
7,2
9,7
11,2

Max.
tensile
force N
700
700
700
700
700
1000
1200
1500

Min. stat.
bending
radius
mm
60,0
60,0
60,0
60,0
60,0
72,0
97,0
115,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
0,87
100
0,87
100
0,00
100
0,867
100
0,867
100
1,245
100
2,189
100
2,97
100

Weight
kg / km

Part no.

28,0
28,0
28,0
28,0
28,0
44,0
77,0
90,0

803931
803932
803930
803658
803659
803660
803661
803668

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM micro fibre-optic cables are characterized by a design that is slim but robust. Around stranded tubes, there is a composite
of swelling fleece with characteristics that ensure the strain relief, and waterproofing in longitudinal direction of the cable. This construction
is particularly used in tubes and channels. These cables can be blowing into microducts.

R 28
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Outdoor Cable


steel armoured

A-DQ(ZN)(SR)2Y

Cable structure

Temperature range

Other data

Core type: Loose tube


Strain relief elements: Glass yarns
Type of armouring: Steel rib
Outer sheath material: PE
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +70C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Longitudinally water-tight acc. to IEC
60794-1-2-F5
Cable, laterally water-tight
UV-resistant

Designation

A-DQ(ZN)(SR)2Y
A-DQ(ZN)(SR)2Y
A-DQ(ZN)(SR)2Y
A-DQ(ZN)(SR)2Y
A-DQ(ZN)(SR)2Y
A-DQ(ZN)(SR)2Y

Number of Fibre type


fibres
4
4
4
12
12
12

Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125

Number of Outer
fibres per approx.
core
mm
4
4
4
12
12
12

9,5
9,5
9,5
9,5
9,5
9,5

Max.
tensile
force N
1500
1500
1500
1500
1500
1500

Min. stat.
bending
radius
mm
95,0
95,0
95,0
95,0
95,0
95,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
2,00
500
2,00
500
2,00
500
2,00
500
2,00
500
2,00
500

Weight
kg / km

Part no.

115,0
115,0
105,0
115,0
115,0
115,0

802917
803925
803927
802918
803926
803928

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are characterized by a compact construction with a swelling fleece. Above-average rodent protection is
achieved with the metallic rodent protection (steel groove) and an outer sheath made of PE. This construction is particularly used in the
area of telecommunication and long distance, but also in regular channels and tubes where rodent infestation is possible.

R 29
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Outdoor Cable


acc. ARCOR Standard

A-DF(ZN)2Y(SR)2Y

Cable structure

Temperature range

Other data

Core type: Loose tube


GRP support element
Strain relief elements: Aramide
Inner sheath material: PE
Type of armouring: Steel rib
Outer sheath material: PE
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -25C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Longitudinally water-tight acc. to IEC
60794-1-2-F5
Cable, laterally water-tight
UV-resistant

Designation

A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y

Number of Fibre type


fibres
12
24
48
60

Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125

Number of Outer
Max.
fibres per approx. mm tensile
core
force N
2
4
12
12

13,0
13,0
13,0
13,0

2700
2700
2700
2700

Min. stat.
bending
radius
mm
130,0
130,0
130,0
130,0

Max.
transverse
pressure
N / cm
800
800
800
800

Weight
kg / km

Part no.

180
180
180
180

82190
800708
800709
800710

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are characterized by a stranded construction with jelly filling. They are made waterproof in longitudinal
direction by filling a jelly mass into the stranding cavities. Above-average rodent protection is achieved with the metallic rodent protection
(steel groove) and the second outer sheath made of PE. This construction is particularly used in the area of telecommunication and long
distance where ARCOR standards must be followed, but also in regular channels and tubes where rodent infestation is possible.

R 30
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Outdoor Cable Hybrid


acc. DIN VDE 0888

A-DSQ(ZN)B2Y

Cable structure

Temperature range

Other data

Core type: Loose tube


GRP support element
Number of fibres per core: 4
Strain relief elements: Glass yarns
Type of armouring: Glass yarns
Outer sheath material: PE
Outer sheath colour: Black

Laying, min.: -10C


Laying, max.: +60C
Operating, min.: -25C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant

Designation

A-DSQ(ZN)B2Y
A-DSQ(ZN)B2Y
A-DSQ(ZN)B2Y
A-DSQ(ZN)B2Y
A-DSQ(ZN)B2Y
A-DSQ(ZN)B2Y
A-DSQ(ZN)B2Y
A-DSQ(ZN)B2Y
A-DSQ(ZN)B2Y

No. of
fibres
4
4
4
4
4
4
4
4
4

Fibre type

No. of
copper
cores

Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125

2
2
2
2
2
2
4
4
4

Dimensions
of copper
cores
mm
1,2
1,2
1,2
1,5
1,5
1,5
1,5
1,5
1,5

Outer
approx.
mm
12,0
12,0
12,0
12,5
12,5
12,5
17,0
17,0
17,0

Max.
Min. stat. Caloric load
tensile bending approx. MJ /
force N radius
m
mm
2100
300
4,80
2100
300
4,80
2100
300
4,80
2300
320
4,80
2300
320
4,80
2300
320
4,80
2600
430
5,80
2600
430
5,80
2600
430
5,80

Max.
transverse
pressure
N / cm
200
200
200
200
200
200
200
200
200

Weight Part no.


kg / km
140,0
140,0
140,0
160,0
160,0
160,0
250,0
250,0
250,0

81209
81255
81256
82561
81257
81258
82786
81259
81260

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are designed especially for use in fibre-optical temperature measurements, such as monitoring of dams.
The extreme mechanical requirements in these areas are fulfilled by the specially designed cable construction. These lines are hybrid glass
fibre lines with copper cores and a special PE outer sheath.

Typical application within a coffer-dam

R 31
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Outdoor Cable Hybrid


acc. DIN VDE 0888

A-DSF(L)(ZN)2Y

Cable structure

Temperature range

Other data

Core type: Loose tube


GRP support element
Number of fibres per core: 12
Strain relief elements: Aramide
Aluminium laminated sheath
Outer sheath material: PE
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -25C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Longitudinally water-tight acc. to IEC
60794-1-2-F5
Cable, laterally water-tight
UV-resistant

Designation

No. of
fibres

Fibre type

No. of
copper
cores

A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y
A-DSF(L)(ZN)2Y

12
12
24
24
48
48
60
60
72
72
96
96
120
120
144
144

Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125

2
4
2
4
2
4
2
4
2
4
2
4
2
4
2
4

Dimensions
of copper
cores
mm
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6

Outer
approx.
mm
12,0
12,0
13,1
13,1
13,1
13,1
14,1
14,1
14,8
14,8
16,6
16,6
18,4
18,4
20,3
20,3

Max.
Min. stat. Caloric load
tensile bending approx. MJ /
force N radius
m
mm
2500
200
4,80
2500
200
4,80
2500
200
4,80
2500
200
4,80
2500
200
4,80
2500
200
4,80
2500
230
4,80
2500
230
4,80
2500
240
5,10
2500
240
5,10
3000
280
6,30
3000
280
6,30
3000
290
8,50
3000
290
8,50
3500
310
10,00
3500
310
10,00

Max.
transverse
pressure
N / cm
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250

Weight Part no.


kg / km
135,0
140,0
139,0
144,0
141,0
146,0
166,0
171,0
179,0
184,0
276,0
281,0
280,0
285,0
331,0
336,0

80495
80497
800753
801182
80501
80503
80504
80506
80507
80509
80510
80512
80513
80515
80516
80518

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM outdoor cables are designed for use under extreme environmental conditions. With the double jelly filling and the Al/PE
laminated sheath, they are water proof in longitudinal and transverse direction. The welded Al tape acts as an additional vapour barrier.
These cables can be layed directly in the ground, in tubes and in ducts. They are mainly used in local and long-distance networks.

R 32
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Aerial Fibre Optic Cable


metall free

ADSS

Cable structure

Temperature range

Other data

Core type: Loose tube


GRP support element
Strain relief elements: Aramide
Inner sheath material: PE
Outer sheath material: PE
Outer sheath colour: Black

Laying, min.: -10C


Laying, max.: +60C
Operating, min.: -25C
Operating, max.: +70C

Sag at 25 C ADSS 9: 2,0 m


Sag at 25 C ADSS 16: 4,5 m
Sag at 25 C ADSS 35: 9,5 m
Halogen-free acc. to 60754-2
Longitudinally water-tight acc. to IEC
60794-1-2-F5
Cable, laterally water-tight
UV-resistant

Designation

Number of
fibres

Fibre type

Number of Span width


fibres per m
core

Max.
tensile
force N

Additional Min. stat.


load
bending
daN / m
radius
mm
0,5
410
0,5
410
0,5
470
0,5
470
0,5
450
0,5
630

Outer
approx.
mm

Weight
kg / km

Part no.

13,6
13,6
15,6
15,6
15,0
20,8

135
137
177
178
161
316

82390
82391
82392
82393
82394
82395

ADSS 9
ADSS 9
ADSS 9
ADSS 9
ADSS 9
ADSS 9

12
24
36
48
60
144

Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125

4
4
6
8
12
12

150
150
150
150
150
150

9
9
9
9
9
9

ADSS 16
ADSS 16
ADSS 16
ADSS 16
ADSS 16
ADSS 16

12
24
36
48
60
144

Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125

4
4
6
8
12
12

350
350
350
350
350
350

16
16
16
16
16
16

0,3
0,3
0,3
0,3
0,3
0,3

430
430
500
500
480
650

14,4
14,4
16,4
16,4
15,8
21,6

162
165
200
201
184
333

82396
82397
82398
82399
82400
82401

ADSS 35
ADSS 35
ADSS 35
ADSS 35
ADSS 35
ADSS 35

12
24
36
48
60
144

Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125
Single-mode E9/125

4
4
6
8
12
12

700
700
700
700
700
700

35
35
35
35
35
35

0,35
0,35
0,35
0,35
0,35
0,35

520
520
580
580
560
730

17,2
17,2
19,2
19,2
18,6
24,4

198
200
240
241
227
381

82402
82403
82404
82405
82406
82407

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM outdoor cables designed as aerial cables for freely suspended installations on posts and masts. The construction is waterproof
in longitudinal direction thanks to the use of jelly-filled bundle cores and swelling tape. The outer jacket is UV-resistant and at the same time
provides protection against environmental influences, such as snow, ice, sun insolation and wind.

R 33
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Cable flexible


WK - mobile

A-V(ZN)11Y

Cable structure

Temperature range

Other data

Core type: Tight buffer


Strain relief elements: Kevlar
Outer sheath colour: Orange

Laying, min.: +5C


Laying, max.: +50C
Operating, min.: -30C
Operating, max.: +70C

Max. tensile force: 650 N


Max. transverse pressure: 40 N / cm
Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant
Resistant to hammer impact acc. to IEC
60794-1-2-E6
Bending cycles acc. to IEC 60794-1-2-E6:
500.000
Oil-resistant

Designation

Number of Fibre type


fibres

Fibre-optic cable
Fibre-optic cable
Fibre-optic cable
Fibre-optic cable
Fibre-optic cable
Fibre-optic cable
Fibre-optic cable

2
2
4
4
4
8
8

Multimode G50/125
Multimode G62.5/125
Multimode G50/125
Multimode G62.5/125
Single-mode E9/125
Multimode G50/125
Multimode G62.5/125

Outer
approx.
mm
5,0
5,0
5,8
5,8
5,8
7,0
7,0

Outer
sheath
material

Inner
sheath
material

PUR
PUR
PUR
PUR
PUR
PUR
PUR

Min. stat.
bending
radius
mm
75
75
90
90
90
105
105

Flame
proof

halogenfree

UL

Weight Part no.


kg / km

yes
yes
yes
yes
yes
yes
yes

yes
yes
yes
yes
yes
yes
yes

no
no
no
no
no
no
no

20
20
31
31
31
47
47

80382
80363
80534
81036
801727
81037
81038

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM cables were designed as mobile field cables. They are easily wound up on a drum and are very tension-proof. As the outer
sheath is tightly anchored on the aramid braiding, it is especially suitable for mobile use. The advantage of these cables is evident especially
where mobile fibre-optic lines are to be installed, such as for drag chains, TV transmission, supervision of protected areas, etc.

R 34
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Cable flexible

WK

WK - UL/CSA

A-V(ZN)Y

Cable structure

Temperature range

Other data

Core type: Tight buffer


Strain relief elements: Aramide
Outer sheath colour: Orange

Laying, min.: 0C
Laying, max.: +50C
Operating, min.: -30C
Operating, max.: +80C

Max. tensile force: 1200 N


Max. transverse pressure: 44 N / cm
Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant
Bending cycles acc. to IEC 60794-1-2-E6:
9.000
Oil-resistant

Designation

Number of Fibre type


fibres

Fibre-optic cable
Fibre-optic cable
Fibre-optic cable

4
4
4

Multimode G50/125
Multimode G62.5/125
Single-mode E9/125

Outer
approx.
mm
7,0
7,0
7,0

Outer
sheath
material

Inner
sheath
material

PVC
PVC
PVC

Min. stat.
bending
radius
mm
75
75
75

Flame
proof

halogenfree

UL

Weight Part no.


kg / km

yes
yes
yes

no
no
no

yes
yes
yes

50
50
50

802792
803934
803935

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM cables were designed as mobile field cables. They are easily wound up on a drum and are very tension-proof. As the outer
sheath is tightly anchored on the aramid braiding, it is especially suitable for mobile use. The advantage of these cables is evident especially
where mobile fibre-optic lines are to be installed, such as windturbine projects, TV transmission, supervision of protected areas, etc.. This
series with PVC jacket is certified according the UL/CSA standard OFNG/ FT4.

R 35
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Cable flexible

WK

WK robust PUR + PVC (UL/CSA)

AT-V(ZN)H(ZN)11Y, AT-V(ZN)Y(ZN)Y

Cable structure

Temperature range

Other data

Core type: Composite buffered


Strain relief elements: Aramide
Outer sheath colour: Black

Laying, min.: -10C


Laying, max.: +50C
Operating, min.: -40C
Operating, max.: +90C

Max. tensile force: 4800 N


Max. transverse pressure: 200 N / cm
Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant
Resistant to hammer impact acc. to IEC
60794-1-2-E6
Bending cycles acc. to IEC 60794-1-2-E6:
9.000
Oil-resistant

Designation

Number of Fibre type


fibres

AT-V(ZN)H(ZN)11Y
AT-V(ZN)Y(ZN)Y
AT-V(ZN)H(ZN)11Y
AT-V(ZN)Y(ZN)Y

4
4
12
12

Multimode G50/125
Multimode G50/125
Multimode G50/125
Multimode G50/125

Outer
approx.
mm
8,5
8,5
12,4
12,4

Outer
sheath
material

Inner
sheath
material

PUR
PVC
PUR
PVC

ULSZH
PVC
ULSZH
PVC

Min. stat.
bending
radius
mm
100
130
190
190

Flame
proof

halogenfree

UL

Weight Part no.


kg / km

yes
yes
yes
yes

yes
no
yes
no

no
yes
no
yes

125
125
320
320

803346
803348
803347
803349

Dimensions and specifications may be changed without prior notice.

Application
The HELUCOM WK range is set apart by its extreme rugged yet highly-flexible design. It is used wherever demanding environmental
conditions and extreme movements occur. The tight buffer structure enables the cable to be pre-assembled in-situ with ease. Applications
are for example Windturbines, TV transmissions, mobile field applications, etc..

R 36
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Cable flexible

WK
AT-V(ZN)YY

Cable structure

Temperature range

Other data

Core type: Composite buffered


Strain relief elements: Aramide
Outer sheath colour: Yellow

Laying, min.: -10C


Laying, max.: +50C
Operating, min.: -40C
Operating, max.: +90C

Max. tensile force: 1200 N


Max. transverse pressure: 100 N / cm
UV-resistant
Resistant to hammer impact acc. to IEC
60794-1-2-E6
Bending cycles acc. to IEC 60794-1-2-E6: 15
Oil-resistant

Designation

Number of Fibre type


fibres

Fibre-optic cable

Multimode G50/125

Outer
approx.
mm
7,4

Outer
sheath
material

Inner
sheath
material

PVC

PVC

Min. stat.
bending
radius
mm
90

Flame
proof

halogenfree

UL

Weight Part no.


kg / km

yes

no

no

65

803364

Dimensions and specifications may be changed without prior notice.

Application
The HELUCOM range is set apart by its extreme rugged yet flexible design. It is used wherever demanding environmental conditions and
movements occur. The tight buffer structure enables the cable to be pre-assembled in-situ with ease. Applications are for example industry
applications, TV transmissions, etc..

R 37
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Breakout Cable


outdoor

AT-V(ZN)HH(BN)2Y

Cable structure

Temperature range

Other data

Core type: Composite buffered


GRP support element
Strain relief elements: Aramide
Inner sheath material: ULSZH
Outer sheath material: PE
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +60C

Longitudinally water-tight acc. to IEC


60794-1-2-F5
UV-resistant
Oil-resistant

Designation

Number of
fibres

Fibre type

Outer
approx.
mm

AT-V(ZN)HH(BN)2Y

Multimode G50/125

13,5

Max.
tensile
force N
1200

Min. stat.
bending
radius
mm
340

Max.
transverse
pressure
N / cm
300

Caloric load Weight Part no.


approx. MJ / kg / km
m
2,95

140

801352

Dimensions and specifications may be changed without prior notice.

Application
The HELUCOM range is set apart by its extreme rugged roden protected design. It is used wherever demanding environmental conditions while
fixed installations occur. The tight buffer structure enables the cable to be pre-assembled in-situ with ease. Applications are for example
industry applications, etc..

R 38
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Cable robust


multimode

AT-VYY

Cable structure

Temperature range

Other data

Core type: Tight buffer


Strain relief elements: Aramide
Outer sheath material: PVC
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +60C

Flame-resistance acc. to IEC 60332-1


Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant
Oil-resistant

Designation

Number of Fibre type


fibres

AT-VYY

Multimode G62.5/125

Number of Outer
fibres per approx.
core
mm
1

Max.
tensile
force N

6,8 x 10,2 400

Min. stat.
bending
radius
mm
110,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
1,10
300

Weight
kg / km

Part no.

76,0

800126

Dimensions and specifications may be changed without prior notice.

Application
This HELUCOM fibre-optic cable is suited for fixed installations in pits and channels, but also for flexible applications as jumper cable. Because
of the robust construction with Single- and Overall-jacket you also can use it in industrial areas. With the core-construction, direct plug
manufacturing, even on site, poses no problems.

R 39
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Cable flexible


HCS

I-VH, I-VHH

Cable structure

Temperature range

Other data

Core type: Composite buffered


Strain relief elements: Aramide
Outer sheath material: FRNC
Outer sheath colour: Orange

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -10C
Operating, max.: +60C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Flame-resistance acc. to IEC 60332-1
Smoke density acc. to IEC 61034

Designation

Number of Fibre type


fibres

Outer
Max.
approx. mm tensile
force N

I-VH
I-VHH

1
2

2,8
3,8 x 6,6

HCS 200/230
HCS 200/230

300
600

Min. stat.
Caloric load Max.
bending radius approx. MJ / transverse
mm
m
pressure
N / cm
40
0,26
10
50
0,52
10

Weight
kg / km

Part no.

2,8
30,0

800579
81238

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM HCS fibre lines are suitable for stationary installation indoors. For heavy-duty mechanical requirements, such as application
in industrial environments, a version with PUR outer sheath is available on request. With a HCS fibre transmission lengths of up to 300m can
be achieved. With the tight buffer construction, direct plug manufacturing, even on site, poses no problems.

R 40
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Breakout Cable robust


flexible
HCS

I-V(ZN)Y11Y

Cable structure

Temperature range

Other data

Core type: Composite buffered


Strain relief elements: Aramide
Outer sheath material: PUR
Outer sheath colour: Red

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +70C

Oil-resistant

Designation

Number of Fibre type


fibres

I-V(ZN)Y11Y

HCS 200/230

Number of Outer
fibres per approx.
core
mm
1

7,0

Max.
tensile
force N
800

Min. stat.
bending
radius
mm
50,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
1,014
150

Weight
kg / km

Part no.

43,0

800980

Dimensions and specifications may be changed without prior notice.

Application
This HELUCOM HCS fibre cable is suitable for fixed installation. Possible applications are normal and heavy-duty mechanical requirements
for example in industrial environments. With the tight buffer construction, direct plug manufacturing, even on site, poses no problems.
With a HCS fibre transmission lengths of up to 300m can be achieved.

R 41
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Breakout Cable robust


HCS

AT-VQH(ZN)B2Y

Cable structure

Temperature range

Other data

Core type: Composite buffered


GRP support element
Strain relief elements: Aramide
Type of armouring: Glass yarns
Outer sheath material: PE
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -25C
Operating, max.: +70C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant
Oil-resistant

Designation

Number of Fibre type


fibres

AT-VQH(ZN)B2Y

HCS 200/230

Number of Outer
fibres per approx.
core
mm
1

11,0

Max.
tensile
force N
1500

Min. stat.
bending
radius
mm
200,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
2,10
500

Weight
kg / km

Part no.

90,0

801196

Dimensions and specifications may be changed without prior notice.

Application
This HELUCOM HCS fibre cable is suitable for fixed installation outdoors. Possible applications are normal and heavy-duty mechanical
requirements for example in industrial environments. This is the reason we also equiped the cable with a non-metallic rodent-protection.With
the tight buffer construction, direct plug manufacturing, even on site, poses no problems. With a HCS fibre transmission lengths of up to
300m can be achieved.

R 42
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Breakout Cable flexible


HCS

AT-V(ZN)HH

Cable structure

Temperature range

Other data

Core type: Composite buffered


GRP support element
Strain relief elements: Aramide
Outer sheath material: FRNC
Outer sheath colour: Black

Laying, min.: -20C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +70C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Flame-resistance acc. to IEC 60332-1
Smoke density acc. to IEC 61034
UV-resistant
Oil-resistant

Designation

Number of Fibre type


fibres

AT-V(ZN)HH

HCS 200/230

Number of Outer
fibres per approx.
core
mm
1

9,0

Max.
tensile
force N
800

Min. stat.
bending
radius
mm
225,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
1,60
100

Weight
kg / km

Part no.

76,0

802260

Dimensions and specifications may be changed without prior notice.

Application
This HELUCOM HCS fibre cable is suitable for fixed and normal flexible installation. Possible applications are normal requirements and also
limited industrial environments. With the tight buffer construction, direct plug manufacturing, even on site, poses no problems. With a HCS
fibre transmission lengths of up to 300m can be achieved.

R 43
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre Optic Breakout Cable robust,


flexible
HCS UL/CSA

I-V(ZN)YY

Cable structure

Temperature range

Other data

Core type: Composite buffered


Strain relief elements: Aramide
Outer sheath material: PVC
Outer sheath colour: Black

Laying, min.: -20C


Laying, max.: +75C
Operating, min.: -30C
Operating, max.: +85C

Flame-resistance acc. to IEC 60332-1 and IEC


60332-3
UV-resistant
Oil-resistant

Designation

Number of Fibre type


fibres

I-V(ZN)YY

HCS 200/230

Number of Outer
fibres per approx.
core
mm
1

7,5

Max.
tensile
force N
800

Min. stat.
bending
radius
mm
100,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
1,40
300

Weight
kg / km

Part no.

68,0

801733

Dimensions and specifications may be changed without prior notice.

Application
This HELUCOM HCS fibre cable is suitable for fixed and normal flexible installations. Possible applications are normal and heavy-duty mechanical
requirements for example in industrial environments. Because of a special PVC jacket this construction is certified by UL (FT1 and FT4). With
the tight buffer construction, direct plug manufacturing, even on site, poses no problems. With a HCS fibre transmission lengths of up to
300m can be achieved.

R 44
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre-optic Universal Cable


HCS

A/I-DQ(ZN)BH

Cable structure

Temperature range

Other data

Core type: Loose tube


Strain relief elements: Glass yarns
Type of armouring: Glass yarns
Outer sheath material: FR/LSOH
Outer sheath colour: Black

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +70C

Corrosiveness acc. to EN50267-2-3


Halogen-free acc. to 60754-2
Flame-resistance acc. to IEC 60332-1
Smoke density acc. to IEC 61034
Longitudinally water-tight acc. to IEC
60794-1-2-F5
UV-resistant

Designation

A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH
A/I-DQ(ZN)BH

Number of Fibre type


fibres
4
8
12
24
48

HCS 200/230
HCS 200/230
HCS 200/230
HCS 200/230
HCS 200/230

Number of Outer
fibres per approx.
core
mm
4
8
12
8
8

8,5
8,5
8,5
17,7
18,9

Max.
tensile
force N
1500
1500
1500
6000
6000

Min. stat.
bending
radius
mm
130,0
130,0
130,0
265,0
285,0

Caloric load Max.


approx. MJ / transverse
m
pressure
N / cm
2,00
150
2,00
150
2,00
150
3,20
300
3,20
300

Weight
kg / km

Part no.

76,0
79,0
82,0
280,0
355,0

801198
802001
802002
802003
802004

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are available either as central bundle core cable or as stranded versions. They are suitable for fixed indoor
and outdoor cabling of buildings and industry facilities. They are used in particular if the installation is to be done in one piece from the
inside to the outside without additional use of couplings. With their black UV-resistant outer sheath and the non-metallic rodent protection,
they are perfectly suited for outdoor use. The halogen-free outer sheath makes installation inhouse possible without any problems.

R 45
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Plastic-fibre cable industry


POF/PE

I-V2Y, I-V2Y(ZN)11Y

Cable structure

Optical characteristic

Temperature range

Fibre type: POF 980/1000


Fibre cladding: PE

Refractive index core: 1,492


Refractive index cladding: 1,419
Numerical aperture: 0,5
Attenuation see table

Laying, min.: -20C


Laying, max.: +80C
Operating, min.: -20C
Operating, max.: +80C

Designation

Outer
Jacket
sheath
colour
material

Outer
approx.
mm

I-V2Y 1P 980/1000
I-V2Y 2P 980/1000
I-V2Y(ZN)11Y 1P 980/1000
I-V2Y(ZN)11Y 2P 980/1000
I-V2Y(ZN)11Y 2P 980/1000
I-V2Y(ZN)11Y 4P 980/1000
I-V2Y(ZN)11Y 2P 980/1000 + 2x1mm Cu
I-V2Y(ZN)11Y 2P 980/1000 + 3x1,5mm Cu

PE
PE
PUR
PUR
PUR
PUR
PUR
PUR

2,2
2,2 x 4,4
5,8
6,0
6,0
7,1
7,8
11,0

Black
Black
Violet
Violet
Violet
Violet
Red
Red

Max.
Min. stat.
tensile bending
force N radius
mm
70
25,0
140
25,0
400
30,0
400
31,0
400
31,0
400
45,0
200
70,0
200
70,0

Fibre
Oilattenuation resistant
160A1
160A1
230A1
230A1
230A1
230A1
230A1
230A1

no
no
yes
yes
yes
yes
yes
yes

Acc. to Weight
DESINA kg / km
no
no
yes
yes
yes
yes
no
no

4,0
8,0
30,0
36,0
36,0
65,0
60,0
132,0

Part no.

80532
80388
81611
80629
81882
80630
82032
82033

Dimensions and specifications may be changed without prior notice.

Application
HELUCOM plastic-fibre cables are used in mechanical engineering, both in mobile and fixed applications. With different constructions, such
as PUR outer sheaths, special strain relief components, hybrid construction with copper cores for power supply or only raw fibre cables,
any possible fields of application are covered. Due to their solidity and their simple adjustability on site, the plastic-fibres (PMMA) are particularly
suitable for applications where trouble-free data transmission in necessary under heavy-duty conditions.

R 46
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Plastic Fibre Cable Industry


POF/PA

I-V4Y(ZN)11Y

Cable structure

Optical characteristic

Temperature range

Fibre type: POF 980/1000


Fibre cladding: PA

Refractive index core: 1,492


Refractive index cladding: 1,419
Numerical aperture: 0,5
Attenuation see table

Laying, min.: -5C


Laying, max.: +50C
Operating, min.: -20C
Operating, max.: +70C

Designation

Outer
Jacket
sheath
colour
material

Outer
approx.
mm

I-V4Y(ZN)11Y 2P980/1000 RUGGED


I-V4Y(ZN)11Y 2P980/1000 FLEX RUGGED
I-V4Y(ZN)11Y 2P980/1000 HEAVY

PUR
PUR
PUR

8,0
8,0
6,0

Red
Red
Red

Max.
Min. stat.
tensile bending
force N radius
mm
100
50,0
100
50,0
100
30,0

Fibre
Oilattenuation resistant
160A1
250A1
160A1

yes
yes
yes

Acc. to Weight
DESINA kg / km
no
no
no

42,0
51,0
28,0

Part no.

801200
801201
801202

Dimensions and specifications may be changed without prior notice.

Application
Signal lines as plastic optical fibre. The use of these transmission systems significantly reduces the number of different cables in a planned
bus installation in machine tools operations. Furthermore, possible EMC problems are prevented by the metal-free construction. The main
application of these cables are in machine construction and automobile industry (PA version).

R 47
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibrespecications
Granded index bres (multimode)
6SHFLFDWLRQ
)LEUHFDWHUJRULH
&RUHGLDPHWHU
1XPHULFDODSHUWXUH
7\SDWWHQXDWLRQ
0LQEDQGZLGWK

QP
QP
QP
QP

)LEUHW\SH*
206WDQGDUGEUH
P

G%NP
G%NP
0+][NP
0+][NP

&ODGGLQJGLDPHWHU
3ULPDU\FRDWLQJGLDPHWHU
&RUHQRQFLUFXODULW\
&ODGGLQJFRQFHQWULFLW\HUURU
&ODGGLQJQRQFLUFXODULW\
6SHFLFDWLRQ
)LEUHFDWHUJRULH
&RUHGLDPHWHU
1XPHULFDODSHUWXUH
7\SDWWHQXDWLRQ
0LQEDQGZLGWK

)LEUHW\SH*
206WDQGDUGEUH
P

G%NP
G%NP
0+][NP
0+][NP
P
P

P


QP
QP
QP
QP

&ODGGLQJGLDPHWHU
3ULPDU\FRDWLQJGLDPHWHU
&RUHQRQFLUFXODULW\
&ODGGLQJFRQFHQWULFLW\HUURU
&ODGGLQJQRQFLUFXODULW\

)LEUHW\SH*
206WDQGDUGEUH
206WDQGDUGEUH
P
P


G%NP
G%NP
G%NP
G%NP
0+][NP
0+][NP
0+][NP
0+][NP
P
P
P
P


P
P



Single-Mode-Fibre
6SHFLFDWLRQ
)LEUHFDWHUJRULH
$WWHQXDWLRQ
'LVSHUVLRQ

)LEUHW\SH( VLQJOHPRGH
,787*G
G%NP
G%NP
SV QP[NP
SV QP[NP
QP
P
P
P
QP
P


QP
QP
QP
QP

:DYHOHQJWK
0RGHHOGGLDPHWHUDWQP
&ODGGLQJGLDPHWHU
3ULPDU\FRDWLQJGLDPHWHU
&XWRIIZDYHOHQJWK
&ODGGLQJFRQFHQWULFLW\HUURU
&ODGGLQJQRQFLUFXODULW\

POF and HCS-Fibre


6SHFLFDWLRQ
&RUHGLDPHWHU
1XPHULFDODSHUWXUH
7\SDWWHQXDWLRQ
0LQ%DQGZLGWK
:DOOWKLFNQHVV

QP
QP
QP
QP

)LEUHW\SH32)3

)LEUHW\SH+&6.

P

G%NP

0+][P


P

GENP
G%NP
0+][NP
0+][NP

P

P
)LEUHVZLWKRWKHUSDUDPHWHUHVRQUHTXHVW

R 48
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre optic Design code acc. to DIN VDE 0888


1

10

11

12

13

14
Lg layerstranding

Bandwidth in MHz for 1 km


(GF) dispersion parameter
in:
ps
nmxkm
Wavelength
B = 850 nm
F = 1300 nm
H = 1550 nm
Attenuation coefcient in dB/km
Cladding diameter in m
Core diameter in m of graded index bre
Field diameter in m of single mode bre
Design
E Single mode bre
G Graded index bre
Number of bres
Number of bres per buffer
Number of multibre buffer
Y
H
B
BY
B2Y

PVC-sheath
Sheath with halogenfree material
Armouring
Armouring with PVC-protective covering sheath
Armouring with PE-protective covering sheath

Y
PVC-sheath
2Y
PE-sheath
4Y
PA-sheath
11Y
PUR-sheath
(L)2Y
PE-Laminated sheath
(ZN)2Y PE-sheath with nometallic strength member
(L)(ZN)2Y PE-Laminated sheath with nonmetallic strength member
F Filling of the cable core with
petroleum jelly
Q Swellingmaterial
S
V
K
H
W
B
D
I
A
AT

Metallic element in the cable core

Tight buffer
Composite buffer bre
Loose buffer nonlled
Loose buffer, lled
Multibre buffer nonlled
Multibre buffer lled

Indoor cable
Outdoor cable
Outdoor fan out cable

R 49
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fibre optic cable production

We manufacture optical bre cables to meet your specic


requests and engineering requirements. A variety of applications
requires the use of very special cable constructions. Hence we
produce, for example, optical bre cables for earth buried or duct
cables comprising differing bre types, e. g. a combination of
graded index bres and single mode bres, or hybrid data
cables where different technologies are brought together within
one cable, optical bre cables with copper data cables.
Hybrid cables are used in buildings where optical bre and copper
cables shall be installed in parallel so as to minimise the pulling
required. These are also used for projects where the optical bre
cable is planned to serve a purpose for future applications.
Metal-free optical bre cables can be used as aerial cable, having a
similar structure as cables for outdoor applications, whereby the
strain relief must be strengthened accordingly. These aerial cables
are used by electricity and railway companies.
Contact us for your special requirements.

R 50
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Inquiry bre optic special cable


To:
HELUKABEL GmbH
Data-, Network- and Bus Technology
Dieselstrae 8-12
71282 Hemmingen
Germany

Sender/Stamp

Phone: +49 7150 9209-181


Fax: +49 7150 970819

Responsible: _________________________________________
Phone.: __________________________ Fax: ________________

No.: _______________

Inquiry:

Date : ______________________

Quantity:__________km

Ohne Step

Continuous

Yearly Quantity: approx. _________ km

Needed delivery date: _____________________________________


Dimensions: __________________________________________________________________________________________
Cable type: __________________________________________________________________________________________
a)

Using:

indoor

outdoor

indoor/outdoor

c.) ambient temperature __________C

G 50/125

Fibre type:

G 62,5/125

b)

xed installation

constant load __________C

E 9/125

S 200/230

Fibre spec.: attenuation: ____________________________

mobil use

shorttime ________C

980/1000 POF

specication: _________________________________

bandwidth: _____________________________
Cable structure:

a)

Tight buffer
Compact ber

b) Metal element
c)

yes

Centrale bundle core

Loose tube lled

Bundle core lled

Loose tube unlled

Bundle core unlled

no
Stranded bundle core

d) Filler: ______________________________
f) Outer jacket:

PVC

g) Laminated jacket:

PE
yes

e) Armouring: _____________________________
PA

PUR

FRNC

no

Min. bending radius: ________ Max. tensile load: ________ Max. transverse pressure: ________ Caloric load: ___________
Fibre colour:

acc. DIN

acc. your demands


(see notice)

Tube colour:

acc. DIN

acc. your demands


(see notice)

Jacket printing: _____________________________________________________________________________________________


Remarks: ___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________

R 51
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Copper Data Cables HELUKAT


All HELUKAT data cables and wires comply with the latest standardisation recommendations and are designed for use in high-speed
networks with transmission rates of 100Mbit/s and higher (e.g. CCDI, TPDDI, ATM, SDH/SONET). All HELUKAT types of cables and
wires meet the requirements of category 5 according to EIA/TIA TSB-36 ISO/IEC DIS 11801, CENELEC pr EN 50173, as well as category
6/7 according to DIN 44312-5/ EN 50288. Cables for Ethernet applications, as well as coax/twinaxial cables cables for IBMs IVS system
complete the product range from HELUKABEL.
The excellent transmission characteristics of HELUKAT data cables and wires constitute enormous challenges for production
equipment and the measurement laboratories. HELUKAT data cables and wires are manufactured using the latest machinery
technologies. These have been designed for producing cables and wires of the categories 5/6/7/8 in accordance with the latest
standardisation recommendations. A special laboratory for high-frequency testing such high transmission rates has been installed
complete with network analyser and computer-controlled equipment for HF cables.

R 52
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents Copper Data Cables


Description
HELUKAT 155 UTP ............................................................................................................................................................
HELUKAT 155 UTP UL .......................................................................................................................................................
HELUKAT 300 UTP UL .......................................................................................................................................................
HELUKAT 100 UTP ex .....................................................................................................................................................
HELUKAT 155 FTP .............................................................................................................................................................
HELUKAT 100 FTP ex ......................................................................................................................................................
HELUKAT 100 FTP FE60 ....................................................................................................................................................
HELUKAT 200 FTP ex, UL ................................................................................................................................................
HELUKAT 200 S-FTP. .........................................................................................................................................................
HELUKAT 200 S-FTP duplex .............................................................................................................................................
HELUKAT 200 S-FTP ex...................................................................................................................................................
HELUKAT 300 U-STP, UL....................................................................................................................................................
HELUKAT 450 S-STP ..........................................................................................................................................................
HELUKAT 450 S-STP duplex..............................................................................................................................................
HELUKAT 500 F-STP..........................................................................................................................................................
HELUKAT 500 F-FTP duplex .............................................................................................................................................
HELUKAT 500 F-FTP, ex ..................................................................................................................................................
HELUKAT 600 S-STP ..........................................................................................................................................................
HELUKAT 600 S-STP duplex..............................................................................................................................................
HELUKAT 600 S-STP ex ...................................................................................................................................................
HELUKAT 600A S-STP PVC/PVC ........................................................................................................................................
HELUKAT 600E S-STP PVC ................................................................................................................................................
HELUKAT 600AE S-STP FRNC/PE ......................................................................................................................................
HELUKAT 1200 S-STP ........................................................................................................................................................
HELUKAT 1200 S-STP duplex............................................................................................................................................
HELUKAT 1200 S-STP ........................................................................................................................................................
HELUKAT 1200 S-STP duplex............................................................................................................................................
HELUKAT 1500 S-STP, Multimedia ....................................................................................................................................
HELUKAT 1500 S-STP duplex, Multimedia .......................................................................................................................
TWINAX LAN-Cable IBM P/N 7 362 211 .............................................................................................................................
IVS LAN-Cable IBM type 1A, type 1A mini, Typ 6A ............................................................................................................
Cheapernet Cable, Yellow Cable, Transceiver Cable.........................................................................................................

Page
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R

54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85

R 53
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

155

Category 5e

UTP

Cable structure

UTP 4x2xAWG 24/1 PVC

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,51 mm
Copper, bare
PE
whbu/bu, whog/og, whgn/gn, whbn/bn
PVC
approx. 4,9 mm
Grey

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


190 Ohm/km max.
50 nF/km nom.
66 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

10
6,3
50,3
44,0

16
8,0
47,3
39,3

62,5
16,5
38,4
21,9

100
21,3
35,3
14,0

155
26,8
33,0
6,2

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 26 kg/km
40 mm
-20C
+60C
0,40 MJ/m
17,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e

Application
HELUKAT155 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable
channels and platforms due to their optimized construction.

Part no.

80053, UTP 4x2xAWG24/1 PVC (U/UTP)

Dimensions and specifications may be changed without prior notice.

R 54
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

155

Category 5e

UTP UL

Cable structure

UTP 4x2xAWG 24/1 PVC, UL

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,53 mm
Copper, bare
PE
whbu/bu, whog/og, whgn/gn, whbn/bn
PVC
approx. 5,2 mm
Grey

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


190 Ohm/km max.
50 nF/km nom.
66 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(db/100m)
(db)
(db)

10
6,1
65,0
58,9

16
7,7
63,0
55,3

62,5
15,2
53,0
37,8

100
19,9
40,0
20,1

155
22,7
37,0
14,3

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 35 kg/km
42 mm
-20C
+60C
0,43 MJ/m
17,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e,
Flame-retardant acc. to IEC 60332-1, Smoke density acc. to IEC 61034, CMX 444

Application
HELUKAT155 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application
in tight cable channels and platforms due to their optimized construction. This type is certified according UL because of the special PVC
jacket.

Part no.

802171, UTP 4x2xAWG24/1 PVC UL (U/UTP)

Dimensions and specifications may be changed without prior notice.

R 55
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

300

Category 6

UTP UL

Cable structure

UTP 4x2xAWG 24/1 PVC, UL

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,55 mm
Copper, bare
PE
whbu/bu, whog/og, whgn/gn, whbn/bn
PVC
approx. 6,8 mm
Grey

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 20 ohm at 101 to 155 MHz


190 Ohm/km max.
50 nF/km nom.
67 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(db/100m)
(db)
(db)

10
5,6
72,0
66,4

16
7,0
70,0
63,0

62,5
14,3
65,0
50,7

100
18,2
63,0
44,8

155
22,9
60,0
37,1

200
26,0
57,0
31,0

300
32,5
55,0
22,5

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 46 kg/km
55 mm
-20C
+60C
0,68 MJ/m
20,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, CMX 444

Application
HELUKAT300 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application
in tight cable channels and platforms due to their optimized construction. This type is certified according UL because of the special PVC
jacket.

Part no.

802172, UTP 4x2xAWG24/1 PVC UL (U/UTP)

Dimensions and specifications may be changed without prior notice.

R 56
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN-Cable

100

Category 5

UTP flex

Cable structure

UTP 4x2xAWG 26/7 PVC

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,48 mm
Copper, bare
PO
whbu/bu, whog/og, whgn/gn, whbn/bn
PVC
approx. 4,5 mm
Grey similar to RAL 7035

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


290 Ohm/km max.
50 nF/km nom.
74 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/10m)
(db)
(db)

10
0,9
53,0
52,1

16
1,2
50,0
48,8

62,5
2,4
41,0
38,6

100
3,1
38,0
34,9

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 17 kg/km
35 mm
-20C
+60C
0,527 MJ/m
11,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5

Application
HELUKAT100 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large
performance reserves and outstanding performance. They can be used to implement services such as Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT100 series can be manufactured
quickly and easily with all common RJ45 plugs.

Part no.

80055, UTP 4x2xAWG 26/7 PVC (U/UTP)

Dimensions and specifications may be changed without prior notice.

R 57
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

155

Category 5e

FTP

Cable structure

FTP 4x2xAWG 24/1 PVC

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,51 mm
Copper, bare
PE
whbu/bu, whog/og, whgn/gn, whbn/bn
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
PVC
approx. 5,9 mm
Yellow similar to RAL 1021

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


170 Ohm/km max.
50 nF/km nom.
69 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

10
5,9
59,0
53,1

16
7,6
53,0
45,4

62,5
15,7
44,0
28,3

100
20,3
40,0
19,7

155
22,0
40,0
18,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 40 kg/km
48 mm
-20C
+60C
0,40 MJ/m
18,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e

Application
HELUKAT155 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable
channels and platforms due to their optimized construction.

Part no.

80043, FTP 4x2xAWG24/1 PVC (F/UTP)

Dimensions and specifications may be changed without prior notice.

R 58
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

100

Category 5

FTP flex

Cable structure

FTP 4x2xAWG 26/7 FRNC

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,48 mm
Copper, bare
PO
whbu/bu, whog/og, whgn/gn, whbn/bn
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
FRNC
approx. 5,7 mm
Grey similar to RAL 7035

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


290 Ohm/km max.
50 nF/km nom.
74 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/10m)
(db)
(db)

10
0,9
58,0
57,1

16
1,2
56,0
54,8

62,5
2,4
45,0
42,6

100
2,9
43,0
40,1

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 31 kg/km
40 mm
-20C
+60C
0,527 MJ/m
14,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3

Application
HELUKAT100 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large
performance reserves and outstanding performance. They can be used to implement services such as Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT100 series can be manufactured
quickly and easily with all common RJ45 plugs.

Part no.

81278, FTP 4x2xAWG 26/7 FRNC (F/UTP)

Dimensions and specifications may be changed without prior notice.

R 59
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cables

100

Category 5

FTP FE60

Cable structure

F-FTP 4x2xAWG 24/1 FR-0H

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,51 mm
Copper, bare
PE + flame resistant tape
whbu/bu, whog/og, whgn/gn, whbn/bn
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
LSZH
approx. 8,3 mm
Red

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


182 Ohm/km max.
53 nF/km nom.
67 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

10
5,7
56,0
50,3

16
7,3
53,0
45,7

62,5
14,9
42,0
27,1

100
19,3
38,0
18,7

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 90 kg/km
130 mm
-20C
+70C
0,91 MJ/m
24,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3

Application
HELUKAT100-FE60 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large
performance reserves and outstanding performance. They can be used to implement services such as Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the thermal characteristics are perfectly suited to realize an isolation
integrity according EN50200-FE60 due to their optimized construction.

Part no.

804045, F-FTP 4x2xAWG 24/1 FR-0H

Dimensions and specifications may be changed without prior notice.

R 60
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cables

200

Category 5e

FTP Flex, UL

Cable structure

FTP 4x2xAWG 26/7 PVC, UL

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,48 mm
Copper, bare
PE
whbu/bu, whog/og, whgn/gn, whbn/bn
Polyester foil, aluminium-lined
PVC
approx. 5,4 mm
Grey similar to RAL 7035

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 20 ohm at 101 to 155 MHz


290 Ohm/km max.
50 nF/km nom.
67 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(db/10m)
(db)
(db)

10
0,9
62,0
61,1

16
1,2
60,0
58,8

62,5
2,4
50,0
47,6

100
3,1
48,0
44,9

200
3,9
45,0
41,1

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 30 kg/km
44 mm
-20C
+60C
0,40 MJ/m
15,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e,
Flame-retardant acc. to IEC 60332-1, Smoke density acc. to IEC 61034, CMX 444

Application
HELUKAT200 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large
performance reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet,
Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT200 series
can be manufactured quickly and easily with all common RJ45 plugs. This type is certified according UL because of the special PVC jacket.

Part no.

802173, FTP 4x2xAWG26/7 PVC UL (F/UTP)

Dimensions and specifications may be changed without prior notice.

R 61
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN-Cable

200

Category 5e

S-FTP

Cable structure

S-FTP 4x2xAWG 24/1 PVC or FRNC

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,51 mm
Copper, bare
Foam-skin-PE
whbu/bu, whog/og, whgn/gn, whbn/bn
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid
PVC / FRNC
approx. 6,0 mm / approx. 6,0 mm
Grey similar to RAL 7035

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


185 Ohm/km max.
48 nF/km nom.
74 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

10
5,6
62,0
56,4

16
7,2
59,0
51,8

62,5
14,4
50,0
35,6

100
18,2
46,0
27,8

200
25,9
40,0
14,6

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 50 kg/km
52 mm
-20C
+60C
0,60 MJ/m / 0,48 MJ/m
27,00 kg/km

Norms
81610:
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e
81609:
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant:
acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2,
Corrosiveness acc. to EN50267-2-3

Application
HELUKAT200 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application
in tight cable channels and platforms due to their optimized construction.

Part no.

81610, S-FTP 4x2xAWG 24/1 PVC (SF/UTP)

81609, S-FTP 4x2xAWG 24/1 FRNC (SF/UTP)

Dimensions and specifications may be changed without prior notice.

R 62
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

200

Category 5e

S-FTP duplex

Cable structure

S-FTP 2x(4x2xAWG 24/1) FRNC

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Cable dimensions:
Outer sheath colour:

0,51 mm
Copper, bare
Foam-skin-PE
whbu/bu, whog/og, whgn/gn, whbn/bn
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid
FRNC
approx. 6,0 mm x 12,5 mm
Green similar to RAL 6018

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


185 Ohm/km max.
48 nF/km nom.
74 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

10
5,6
62,0
56,4

16
7,2
59,0
51,8

62,5
14,4
50,0
35,6

100
18,2
46,0
27,8

200
25,9
40,0
14,6

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 100 kg/km


52 mm
-20C
+60C
0,96 MJ/m
54,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e,
Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3

Application
HELUKAT200 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application
in tight cable channels and platforms due to their optimized construction.

Part no.

81123, S-FTP 2x(4x2xAWG 24/1) FRNC (SF/UTP)

Dimensions and specifications may be changed without prior notice.

R 63
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

200

Category 5e

S-FTP flex

Cable structure

S-FTP 4x2xAWG 26/7 FRNC

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,48 mm
Copper, bare
PO
whbu/bu, whog/og, whgn/gn, whbn/bn
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid
FRNC
approx. 5,3 mm
Grey similar to RAL 7035

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


260 Ohm/km max.
47 nF/km nom.
69 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/10m)
(db)
(db)

10
0,8
58,0
57,2

16
1,1
56,0
54,9

62,5
2,4
45,0
42,6

100
2,9
43,0
40,1

200
4,3
37,0
32,7

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 35 kg/km
46 mm
-20C
+60C
0,543 MJ/m
24,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e,
Flame-retardant acc. to IEC 60332-1, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3

Application
HELUKAT200 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large
performance reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet,
Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT200 series
can be manufactured quickly and easily with all common RJ45 plugs.

Part no.

81254, S-FTP 4x2xAWG 26/7 FRNC (SF/UTP)

Dimensions and specifications may be changed without prior notice.

R 64
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

300

Category 6

U-STP, UL

Cable structure

S-UTP 4x2xAWG 26/7 PVC, UL

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,48 mm
Copper, tinned
Foam-skin-PE
whbu/bu, whog/og, whgn/gn, whbn/bn
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
PVC
approx. 5,9 mm
Grey similar to RAL 7035

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 20 ohm at 101 to 155 MHz


290 Ohm/km max.
45 nF/km nom.
77 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(db/10m)
(db)
(db)

10
0,9
90,0
89,1

16
1,1
88,0
86,9

62,5
2,2
83,0
80,8

100
2,7
80,0
77,3

200
3,9
76,0
72,1

300
4,7
73,0
68,3

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 37 kg/km
48 mm
-20C
+60C
0,41 MJ/m
20,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, CMX 444

Application
HELUKAT300 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large
performance reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet,
Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT300 series
can be manufactured quickly and easily with all common RJ45 plugs. This type is certified according UL because of the special PVC jacket.

Part no.

802174, U-STP 4x2xAWG 26/7 PVC

Dimensions and specifications may be changed without prior notice.

R 65
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

450

Category 6

S-STP

Cable structure

S-STP 4x2xAWG 24/1 FRNC

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,52 mm
Copper, bare
Foam-skin-PE
wh/bu, wh/og, wh/gn, wh/bn
Polyester foil, aluminium-lined
Polyester foil, aluminium-lined
FRNC
approx. 7,4 mm
Green similar to RAL 6018

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 ohm at 101 to 450 MHz
146 Ohm/km max.
43 nF/km nom.
79 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

10
5,4
100,0
94,6

16
7,0
100,0
93,0

62,5
13,8
95,8
82,0

100
17,6
94,5
76,9

200
26,0
91,0
65,0

300
34,0
87,0
53,0

450
38,5
84,3
45,8

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 50 kg/km
59 mm
-20C
+60C
0,57 MJ/m
24,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3

Application
HELUKAT450 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application
in tight cable channels and platforms due to their optimized construction.

Part no.

82501, S-STP 4x2xAWG 24/1 FRNC (S/FTP)

Dimensions and specifications may be changed without prior notice.

R 66
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

450

Category 6

S-STP duplex

Cable structure

S-STP 2x(4x2xAWG 24/1) FRNC

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Cable dimensions:
Outer sheath colour:

0,52 mm
Copper, bare
Foam-skin-PE
wh/bu, wh/og, wh/gn, wh/bn
Polyester foil, aluminium-lined
Polyester foil, aluminium-lined
FRNC
approx. 7,4 mm x 15,0 mm
Green similar to RAL 6018

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 ohm at 101 to 450 MHz
146 Ohm/km max.
43 nF/km nom.
79 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

10
5,4
100,0
94,6

16
7,0
100,0
93,0

62,5
13,8
95,8
82,0

100
17,6
94,5
76,9

200
26,0
91,0
65,0

300
34,0
87,0
53,0

450
38,5
84,3
45,8

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 100 kg/km


59 mm
-20C
+60C
1,14 MJ/m
48,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3

Application
HELUKAT450 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application
in tight cable channels and platforms due to their optimized construction.

Part no.

82502, S-STP 2x(4x2xAWG 24/1) FRNC (S/FTP)

Dimensions and specifications may be changed without prior notice.

R 67
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

500

Category 6A

F-FTP

Cable structure

F/FTP 4x2xAWG 23/1 LSZH

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,57 mm
Copper, bare
Foam-skin-PE
wh/bu, wh/og, wh/gn, wh/bn
Polyester foil, aluminium-lined
Polyester foil, aluminium-lined
LSZH
approx. 7,5 mm
Blue Lilac similar to RAL 4005

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 ohm at 101 to 500 MHz
160 Ohm/km max.
45 nF/km nom.
80 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(db/100m)
(db)
(db)

10
5,7
100,0
94,3

16
7,2
100,0
92,8

62,5
14,2
100,0
85,8

100
18,1
97,4
79,3

200
25,8
92,9
67,1

250
29,0
91,4
62,4

300
31,9
90,2
58,3

500
41,8
86,9
45,1

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 50 kg/km
100 mm
-20C
+60C
0,55 MJ/m
28,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6A,
Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3

Application
HELUKAT 500 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet,
Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited
for the application in tight cable channels and platforms due to their optimized construction.

Part no.

803378, F-FTP 4x2xAWG 23/1 LSZH

Dimensions and specifications may be changed without prior notice.

R 68
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

500

Kategorie 6A

F-FTP duplex

Cable structure

F/FTP 2x(4x2xAWG 23/1) LSZH

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Cable dimensions:
Outer sheath colour:

0,57 mm
Copper, bare
Foam-skin-PE
wh/bu, wh/og, wh/gn, wh/bn
Polyester foil, aluminium-lined
Polyester foil, aluminium-lined
LSZH
approx. 7,8 mm x 15,9 mm
Blue Lilac similar to RAL 4005

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 ohm at 101 to 500 MHz
160 Ohm/km max.
45 nF/km nom.
80 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(db/100m)
(db)
(db)

10
5,7
100,0
94,3

16
7,2
100,0
92,8

62,5
14,2
100,0
85,8

100
18,1
97,4
79,3

200
25,8
92,9
67,1

250
29,0
91,4
62,4

300
31,9
90,2
58,3

500
41,8
86,9
45,1

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 100 kg/km


100 mm
-20C
+60C
1,13 MJ/m
56,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6A,
Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3

Application
HELUKAT 500 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet,
Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited
for the application in tight cable channels and platforms due to their optimized construction.

Part no.

803379, F/FTP 2x(4x2xAWG 23/1) LSZH

Dimensions and specifications may be changed without prior notice.

R 69
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

500

Category 6A

F-FTP, flex

Cable structure

U/FTP 4x2xAWG 26/7 (stranded) LSZH

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,48 mm
Copper, bare
Foam-skin-PE
wh/bu, wh/og, wh/gn, wh/bn
Polyester foil, aluminium-lined
LSZH
approx. 5,8 mm
Grey similar to RAL 7035

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 ohm at 101 to 500 MHz
165 Ohm/km max.
54 nF/km nom.
78 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/10m)
(db)
(db)

10
0,8
100,0
99,2

16
1,1
100,0
98,9

62,5
2,1
100,0
97,9

100
2,7
97,0
94,3

200
3,9
92,0
88,1

250
4,4
91,0
86,6

500
6,3
86,0
79,7

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 35 kg/km
49 mm
-20C
+60C
0,39 MJ/m
15,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6A,
Flame-retardant acc. to IEC 60332-1, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3

Application
HELUKAT 500 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large
performance reserves and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet,
Fast Ethernet, Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT500
series can be manufactured quickly and easily with many common RJ45 plugs.

Part no.

804043, U/FTP 4x2xAWG 26/7 LSZH

Dimensions and specifications may be changed without prior notice.

R 70
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

600

Category 7e

S-STP

Cable structure

S-STP 4x2xAWG 23/1 FRNC

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,57 mm
Copper, bare
Foam-skin-PE
wh/bu, wh/og, wh/gn, wh/bn
Polyester foil, aluminium-lined
Cu braid
FRNC
approx. 7,5 mm
Blue Lilac similar to RAL 4005

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 ohm at 101 to 1000 MHz
130 Ohm/km max.
43 nF/km nom.
79 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

10
5,6
100,0
94,4

16
7,1
100,0
92,9

62,5
13,9
96,0
82,1

100
17,5
94,0
76,5

200
25,2
88,0
62,8

300
32,1
84,0
51,9

600
44,9
73,0
28,1

900
55,0
71,0
16,0

1000
58,0
69,0
9,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 60 kg/km
60 mm
-20C
+60C
0,60 MJ/m
30,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e,
Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3

Application
HELUKAT600 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application
in tight cable channels and platforms due to their optimized construction.

Part no.

80810, S-STP 4x2xAWG 23/1 FRNC (S/FTP)

Dimensions and specifications may be changed without prior notice.

R 71
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

600

Category 7e

S-STP duplex

Cable structure

S-STP 2x(4x2xAWG 23/1) FRNC

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Cable dimensions:
Outer sheath colour:

0,57 mm
Copper, bare
Foam-skin-PE
wh/bu, wh/og, wh/gn, wh/bn
Polyester foil, aluminium-lined
Cu braid
FRNC
approx. 7,5 mm x 16,0 mm
Blue Lilac similar to RAL 4005

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 ohm at 101 to 1000 MHz
130 Ohm/km max.
43 nF/km nom.
79 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

10
5,6
100,0
94,4

16
7,1
100,0
92,9

62,5
13,9
96,0
82,1

100
17,5
94,0
76,5

200
25,2
88,0
62,8

300
32,1
84,0
51,9

600
44,9
73,0
28,1

900
55,0
71,0
16,0

1000
58,0
69,0
9,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 120 kg/km


60 mm
-20C
+60C
1,20 MJ/m
60,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e,
Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3

R
Application
HELUKAT600 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application
in tight cable channels and platforms due to their optimized construction.

Part no.

81446, S-STP 2x(4x2xAWG 23/1) FRNC (S/FTP)

Dimensions and specifications may be changed without prior notice.

R 72
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

600

Category 7

S-STP flex

Cable structure

S-STP 4x2xAWG 26/7 FRNC

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,48 mm
Copper, bare
Foam-skin-PE
wh/bu, wh/og, wh/gn, wh/bn
Polyester foil, aluminium-lined
Cu braid
FRNC
approx. 5,9 mm
Grey similar to RAL 7035

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 ohm at 101 to 600 MHz
264 Ohm/km max.
45 nF/km nom.
77 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/10m)
(db)
(db)

10
0,8
96,0
95,2

16
1,0
96,0
95,0

62,5
2,0
95,0
93,0

100
2,6
94,0
91,4

200
4,0
88,0
84,0

300
4,9
86,0
81,1

600
6,3
80,0
73,7

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 42 kg/km
55 mm
-20C
+60C
0,47 MJ/m
22,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3

Application
HELUKAT600 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large
performance reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet,
Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT600 series
can be manufactured quickly and easily with all common RJ45 plugs.

Part no.

80294, S-STP 4x2xAWG 26/7 FRNC (S/FTP)

Dimensions and specifications may be changed without prior notice.

R 73
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable Outdoor

600A

Category 7

S-STP PVC/PVC

Cable structure

S-STP 4x2xAWG 23/1 PVC/PVC

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Inner sheath material:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,58 mm
Copper, bare
Foam-skin-PE
wh/bu, wh/og, wh/gn, wh/bn
PVC
Polyester foil, aluminium-lined
Cu braid
PVC
approx. 11,6 mm
Black similar to RAL 9005

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 ohm at 101 to 600 MHz
160 Ohm/km max.
43 nF/km nom.
79 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

10
5,8
85,0
79,2

16
7,4
85,0
77,6

62,5
14,6
85,0
70,4

100
18,4
85,0
66,6

200
26,2
83,0
56,8

300
32,1
80,0
47,9

600
49,0
80,0
31,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 153 kg/km


95 mm
-30C
+70C
2,62 MJ/m
32,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034

R
Application
HELUKAT 600 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. The serie of HELUKAT 600A with a double PVC jacket is constructed especially
for outdoor applications like laying at house walls or in cable lines.

Part no.

801147, S-STP 4x2xAWG 23/1 PVC/PVC (S/FTP)

Dimensions and specifications may be changed without prior notice.

R 74
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable Direct Burial

600E

Category 7

S-STP PVC

Cable structure

S-STP 4x2xAWG 23/1 direct burial

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,58 mm
Copper, bare
PO
wh/bu, wh/og, wh/gn, wh/bn
Polyester foil, aluminium-lined
Cu braid
PVC
approx. 9,8 mm
Black

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 ohm at 101 to 600 MHz
150 Ohm/km max.
42 nF/km nom.
79 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

10
5,8
85,0
79,2

16
7,4
85,0
77,6

62,5
14,6
85,0
70,4

100
18,4
85,0
66,6

200
26,2
83,0
56,8

300
32,1
80,0
47,9

600
49,0
80,0
31,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 102 kg/km


100 mm
-45C
+65C
1,40 MJ/m
32,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, UL 1581 VW-1

Application
HELUKAT 600 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. The serie of HELUKAT 600E with a cold resistant PVC jacket is constructed
especially for outdoor applications like laying at house walls or direct burial.

Part no.

802167, S-STP 4x2xAWG23/1 PVC (S/FTP)

Dimensions and specifications may be changed without prior notice.

R 75
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable / armoured

600AE

Category 7

S-STP FRNC/PE

Cable structure

S-STP 4x2xAWG 23/1 FRNC/PE

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Inner sheath material:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,58 mm
Copper, bare
Foam-skin-PE
wh/bu, wh/og, wh/gn, wh/bn
FRNC
Polyester foil, aluminium-lined
Cu braid
Steel shaft
PE
approx. 12,2 mm
Black

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 ohm at 101 to 600 MHz
150 Ohm/km max.
43 nF/km nom.
79 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

10
5,8
85,0
79,2

16
7,4
85,0
77,6

62,5
14,6
85,0
70,4

100
18,4
85,0
66,6

200
26,2
83,0
56,8

300
32,1
80,0
47,9

600
49,0
80,0
31,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 155 kg/km


330 mm
-45C
+70C
2,30 MJ/m
32,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7

R
Application
HELUKAT 600 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. The serie of HELUKAT 600AE with a FRNC/PE double jacket and the rodent
protection is constructed especially for outdoor and direct burial applications.

Part no.

802168, S-STP 4x2xAWG 23/1 FRNC/PE

Dimensions and specifications may be changed without prior notice.

R 76
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

1200

Category 7A

S-STP

Cable structure

S/FTP 4x2xAWG 23/1 LSZH

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,57 mm
Copper, bare
Foam-skin-PE
wh/bu, wh/og, wh/gn, wh/bn
Polyester foil, aluminium-lined
Cu braid
LSZH
approx. 7,9 mm
Blue Lilac similar to RAL 4005

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 ohm at 101 to 1200 MHz
160 Ohm/km max.
45 nF/km nom.
80 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(db/100m)
(db)
(db)

10
5,4
105,0
99,6

16
6,8
105,0
98,2

62,5
13,3
105,0
91,7

100
16,9
100,0
83,1

200
24,2
95,0
70,8

300
29,8
93,0
63,2

600
42,9
88,0
45,1

900
53,2
85,0
31,8

1000
56,3
84,0
27,7

1200
62,1
82,0
19,9

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 60 kg/km
60 mm
-20C
+60C
0,56 MJ/m
35,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7A,
Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3

Application
HELUKAT1200-7A data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet,
Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited
for the application in tight cable channels and platforms due to their optimized construction.

Part no.

803380, S-STP 4x2xAWG 23/1 LSZH (S/FTP)

Dimensions and specifications may be changed without prior notice.

R 77
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

1200

Category 7A

S-STP duplex

Cable structure

S/FTP 4x2xAWG 23/1 LSZH

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Cable dimensions:
Outer sheath colour:

0,57 mm
Copper, bare
Foam-skin-PE
wh/bu, wh/og, wh/gn, wh/bn
Polyester foil, aluminium-lined
Cu braid
LSZH
approx. 16,8 mm x 7,9 mm
Blue Lilac similar to RAL 4005

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 ohm at 101 to 1200 MHz
160 Ohm/km max.
56 nF/km nom.
80 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(db/100m)
(db)
(db)

10
5,4
105,0
99,6

16
6,8
105,0
98,2

62,5
13,3
105,0
91,7

100
16,9
100,0
83,1

200
24,2
95,0
70,8

300
29,8
93,0
63,2

600
42,9
88,0
45,1

900
53,2
85,0
31,8

1000
56,3
84,0
27,7

1200
62,1
82,0
19,9

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 120 kg/km


60 mm
-20C
+60C
1,15 MJ/m
70,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7A,
Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3

R
Application
HELUKAT1200-7A data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet,
Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited
for the application in tight cable channels and platforms due to their optimized construction.

Part no.

803381, S-STP 4x2xAWG 23/1 LSZH (S/FTP)

Dimensions and specifications may be changed without prior notice.

R 78
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

1200

Category 7e

S-STP

Cable structure

S-STP 4x2xAWG 22/1 FRNC

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:

0,64 mm
Copper, bare
Foam-skin-PE
wh/bu, wh/og, wh/gn, wh/bn
Polyester foil, aluminium-lined
Cu braid
FRNC
approx. 7,7 mm

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 ohm at 101 to 1200 MHz
120 Ohm/km max.
43 nF/km nom.
79 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

10
4,9
100,0
95,1

16
6,3
100,0
93,7

62,5
12,7
95,0
82,3

100
16,3
93,0
76,7

200
23,5
90,0
66,5

300
29,4
87,0
57,6

600
42,8
81,0
38,2

1000
53,0
78,0
25,0

1200
59,0
77,0
18,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 66 kg/km
72 mm
-20C
+60C
0,70 MJ/m
40,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e,
Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3

Application
HELUKAT1200 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application
in tight cable channels and platforms due to their optimized construction.

Part no.

81699, S-STP 4x2xAWG 22/1 FRNC (S/FTP)

Dimensions and specifications may be changed without prior notice.

R 79
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

1200

Category 7e

S-STP duplex

Cable structure

S-STP 2x(4x2xAWG 22/1) FRNC

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Cable dimensions:

0,64 mm
Copper, bare
Foam-skin-PE
wh/bu, wh/og, wh/gn, wh/bn
Polyester foil, aluminium-lined
Cu braid
FRNC
approx. 7,7 mm x 16,5 mm

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 ohm at 101 to 1200 MHz
120 Ohm/km max.
43 nF/km nom.
79 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

10
4,9
100,0
95,1

16
6,3
100,0
93,7

62,5
12,7
95,0
82,3

100
16,3
93,0
76,7

200
23,5
90,0
66,5

300
29,4
87,0
57,6

600
42,8
81,0
38,2

1000
53,0
78,0
25,0

1200
59,0
77,0
18,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 133 kg/km


72 mm
-20C
+60C
1,50 MJ/m
80,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e,
Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3

Application
HELUKAT 1200 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application
in tight cable channels and platforms due to their optimized construction.

Part no.

800647, S-STP 2x(4x2xAWG 22/1) FRNC (S/FTP)

Dimensions and specifications may be changed without prior notice.

R 80
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Multimedia Cable

1500

Category 7e

S-STP

Cable structure

S-STP 4x2xAWG 22/1 FRNC

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:

0,64 mm
Copper, bare
Foam-skin-PE
wh/bu, wh/og, wh/gn, wh/bn
Polyester foil, aluminium-lined
Cu braid
FRNC
approx. 8,6 mm

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 ohm at 101 to 1200 MHz
120 Ohm/km max.
42 nF/km nom.
80 %

Typical values
Frequenz
Dmpfung
Next
ACR

(MHz)
(db/100m)
(db)
(db)

10
4,2
110,0
106,0

16
6,3
110,0
103,7

62,5
12,7
110,0
97,3

100
14,4
110,0
95,6

200
21,5
110,0
88,5

300
27,5
105,0
77,5

600
37,7
100,0
62,3

1000
49,0
92,0
43,0

1200
54,9
88,0
33,1

1500
62,0
73,0
11,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 80 kg/km
68 mm
-20C
+60C
0,74 MJ/m
53,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e,
Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3

Application
HELUKAT 1500 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet,
Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. That means applications such as multimedia (TV, Video, Data,
Speach) are no problem for this series.Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction.

Part no.

802169, S-STP 4x2xAWG 22/1 FRNC (S/FTP)

Dimensions and specifications may be changed without prior notice.

R 81
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Multimedia Cable

1500

Category 7e

S-STP duplex

Cable structure

S-STP 2x(4x2xAWG 22/1) FRNC

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Cable dimensions:

0,64 mm
Copper, bare
Foam-skin-PE
wh/bu, wh/og, wh/gn, wh/bn
Polyester foil, aluminium-lined
Cu braid
FRNC
approx. 8,6 mm x 18,2 mm

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 ohm at 101 to 1200 MHz
120 Ohm/km max.
42 nF/km nom.
80 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(db/100m)
(db)
(db)

10
4,2
110,0
106,0

16
6,3
110,0
103,7

62,5
12,7
110,0
97,3

100
14,4
110,0
95,6

200
21,5
110,0
88,5

300
27,5
105,0
77,5

600
37,7
100,0
62,3

1000
49,0
92,0
43,0

1200
54,9
88,0
33,1

1500
62,0
73,0
11,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 160 kg/km


68 mm
-20C
+60C
1,50 MJ/m
106,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e,
Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3

Application
HELUKAT1500 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet,
Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. That means applications such as multimedia (TV, Video, Data,
Speach) are no problem for this series.Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction.

Part no.

802170, S-STP 2x(4x2xAWG 22/1) FRNC (S/FTP)

Dimensions and specifications may be changed without prior notice.

R 82
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

TWINAX
IBM P/N 7 362 211

Cable structure

Twinax indoor or outdoor




Inner conductor diameter:

1 x AWG 20, Copper, bare + 1 x AWG 20,


Copper, tinned
Copper, bare
PE
Transparent
Solid PE dielectric
Cu braid, tinned
PVC / PE
approx. 8,3 mm / approx. 9,3 mm
Black

Conductor material:
Core insulation:
Core colours:
Screen over stranding element:
Screen over stranding 1:
Screen over stranding 2:
Outer sheath material:
Outer diameter:
Outer sheath colour:

Electrical data
Characteristic impedance:
Mutual capacitance:
Rel. propagation velocity:

105 Ohm
53 nF/km nom.
66 %

Typical values
Frequency
Attenuation

(MHz)
(dB/100m)

100
14,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 88 kg/km
125 mm
-10C
+80C
51,00 kg/km

Application
HELUKABEL TWINAX cables are used in the area of the IBM computer systems S/36, S/38 and AS400. By using a special PE sheath, an outdoor
version was developed as well.

Part no.

80072, IBM P/N 7362211 Twinax indoor

80073, IBM P/N 7362211 Twinax outdoor

Dimensions and specifications may be changed without prior notice.

R 83
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable

IVS
IBM P/N 33G2772, IBM P/N 33G8224, IBM P/N 33G2775

Cable structure

IBM P/N 33G2772 IBM P/N 33G2775 IBM P/N 33G8224


type 1A
type 6A
type 1A mini

Inner conductor diameter:


Conductor material:
Core insulation:
Number of cores:
Core colours:
Screen over stranding element:

0,64 mm
Copper, bare
Foam-skin-PE
4
bk/og, rd/gn
Polyester foil,
aluminium-lined
Cu braid, tinned
PVC
approx. 7,6 mm x 11,9 mm
Black

0,48 mm
Copper, bare
Foam-skin-PE
4
bk/og, rd/gn
Polyester foil,
aluminium-lined
Cu braid, tinned
PVC
approx. 7,8 mm
Black

0,4 mm
Copper, bare
Foam-skin-PE
4
bk/og, rd/gn
Polyester foil,
aluminium-lined
Cu braid, tinned
PVC
approx. 5,5 mm x 8,9 mm
Black

150 Ohm
15 ohm at 3 to 20 MHz
185 Ohm
18.5 ohm at 38.4 kHz
270 Ohm
27 ohm at 9.6 kHz
57,1 Ohm/km
78 %

150 Ohm
15 ohm at 3 to 20 MHz
235 Ohm
35.25 ohm at 38.4 kHz
390 Ohm
58.5 ohm at 9.6 kHz
151 Ohm/km
-

150 Ohm
15 ohm at 3 to 20 MHz
235 Ohm
23.5 ohm at 38.4 kHz
390 Ohm
39 ohm at 9.6 kHz
151 Ohm/km
78 %

20
7,4
80,0

20
4,9
50,0

Screen over stranding 1:


Screen over stranding 2:
Outer sheath material:
Cable dimensions:
Outer sheath colour:

Electrical data
Characteristic impedance:

Direct current resistance:


Rel. propagation velocity:

Typical values
Frequency
Attenuation
Next

(MHz)
(dB/100m)
(db)

100
18,7
60,0

100
12,3
39,0

20
7,4
60,0

100
18,7
49,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 85 kg/km
110 mm
-10C
+70C
1,70 MJ/m
38,00 kg/km

approx. 70 kg/km
117 mm
-10C
+70C
0,78 MJ/m
25,00 kg/km

approx. 60 kg/km
84 mm
-10C
+70C
0,68 MJ/m
21,00 kg/km

Application
HELUKABEL IVS types are used in the area of the IVS system, developed by IBM. They correspond to the wiring guidelines set by IBM.

Part no.

80068, IBM P/N 33G2772


type 1A

80071, IBM P/N 33G2775


type 6A

80070, IBM P/N 33G8224


type 1A mini

Dimensions and specifications may be changed without prior notice.

R 84
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

LAN Cable
Ethernet Cheapernet Cable, Yellow Cable, Transceiver Cable

Cable structure

Cheapernet
Cable

Yellow Cable

Transceiver
Cable

Inner conductor diameter:


Conductor material:
Core insulation:
Number of cores:
Core colours:
Screen over stranding element:

0,72 mm
Copper, tinned
Foam-skin-PE
1
White
-

Screen over stranding 1:

0,89 mm
Copper, tinned
PE
8
gn/bu, ye/og, gy/wh, rd/bk
Polyester foil,
aluminium-lined
-

Screen over stranding 2:

Polyester foil,
aluminium-lined
Cu braid, tinned

2,17 mm
Copper, bare
Foam-skin-PE
1
Transparent
Polyester foil,
aluminium-lined
Cu braid, tinned

Outer sheath material:


Outer diameter:
Outer sheath colour:

PVC
approx. 4,6 mm
Grey

Polyester foil,
aluminium-lined
PVC
approx. 10,3 mm
Yellow

Polyester foil,
aluminium-lined
PVC
approx. 10,6 mm
Grey

50 Ohm
88 nF/km nom.
50 Ohm/km
77 %

50 Ohm
78 nF/km nom.
85 %

78 Ohm
64 nF/km nom.
66 %

Electrical data
Characteristic impedance:
Mutual capacitance:
Direct current resistance:
Rel. propagation velocity:

Typical values
Frequency
Attenuation

(MHz)
(dB/100m)

4
1,2

10
1,8

4
3,3

10
4,6

4
4,2

10
6,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 32 kg/km
69 mm
-10C
+80C
0,36 MJ/m
21,00 kg/km

approx. 176 kg/km


117 mm
-10C
+70C
128,00 kg/km

approx. 142 kg/km


159 mm
-10C
+60C
95,00 kg/km

Application
HELUKABEL ETHERNET types are used as baselines (Yellow + Cheapernet) and cable connections (Transceiver or AUI) within the Ethernet
wiring structure.

Part no.

80044, Cheapernet cable

80074, Yellow cable

80076, Transceiver cable

Dimensions and specifications may be changed without prior notice.

R 85
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Bus Cables HELUKABEL


Bus technology is being used in an increasing number of industrial applications. This technology can be applied in every branch in
industry where process-control techniques are used. The enormous pressures of competitiveness and costs in all areas of process
control emphasise the need for even more rationalisation and greater efficency. The traditional method of parallel wiring for the
equipment and machines does not have the flexibility and thus constitutes a major factor in costs and time. The potential for saving
costs from internetworking the machinery by bus systems is very high. So as to keep the amount of cabling low, the information
from the master controller is sent over a bus network and is potentially available to all components in the system. Only those
components specifically addressed by the information can respond and process these signals. All types of cables and wires used in
all common bus systems are available from HELUKABEL.

R 86
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents Bus Cables


Description
Industrial Ethernet HELUKAT 600IND S-STP, ROBUST........................................................................................................
Industrial Ethernet HELUKAT 600IND S-STP, SHIPLINE ......................................................................................................
Industrial Ethernet HELUKAT 600IND S-STP, ROBUSTFLEX ................................................................................................
Industrial Ethernet HELUKAT 500IND S-STP, 10GIG ...........................................................................................................
Industrial Ethernet HELUKAT 250S S-FTP, Drag Chain ......................................................................................................
Industrial Ethernet HELUKAT 200IND S-FTP, ROBUSTFLEX ................................................................................................
Industrial Ethernet S-FTP, WK Industrial 105C ................................................................................................................
Industrial Ethernet HELUKAT 100S ECO S-FTP 4-core, Drag Chain ..................................................................................
Industrial Ethernet HELUKAT 100S ECO S-FTP 4-pair, Drag Chain ....................................................................................
Industrial Ethernet HELUKAT 200S S-FTP 4-core, Drag Chain ..........................................................................................
Industrial Ethernet HELUKAT 200S S-FTP 4-pair, Drag Chain ...........................................................................................
Industrial Ethernet HELUKAT 100T S-FTP Tordierex .......................................................................................................
Industrial Ethernet PROFInet Type A, xed installed + robust ........................................................................................
Industrial Ethernet PROFInet Type A, radiation resistant + armoured ...........................................................................
Industrial Ethernet PROFInet Type B, hybrid ...................................................................................................................
Industrial Ethernet PROFInet Type B, SHIPLINE + FESTOON.............................................................................................
Industrial Ethernet PROFInet Type B and C, exible + high exible ...............................................................................
Industrial Ethernet PROFInet Type C, Torsion ..................................................................................................................
Probus L2, xed installation, indoor ..............................................................................................................................
Probus L2, xed installation, outdoor or Industrial Area ..............................................................................................
Probus L2, Direct Burial without + with Armouring ......................................................................................................
Probus L2, 7-wire............................................................................................................................................................
Probus L2, Drag Chain ....................................................................................................................................................
Probus, ET200X + ECOFAST ............................................................................................................................................
Probus, SHIPLINE and High Temperature ......................................................................................................................
Probus DESINA-HYBRID-BUS .........................................................................................................................................
Probus L2, TORSION + FESTOON .....................................................................................................................................
Probus PA .......................................................................................................................................................................
Probus PA, armoured .....................................................................................................................................................
Probus PA, Long Distance ..............................................................................................................................................
Probus SK, Indoor + Outdoor .........................................................................................................................................
Probus SK, FRNC + Industry ...........................................................................................................................................
Probus SK, Drag Chain ....................................................................................................................................................
FOUNDATION Fieldbus Basic ..........................................................................................................................................
FOUNDATION Fieldbus Type A + gnge ..........................................................................................................................
FOUNDATION Fieldbus Type A, armoured.....................................................................................................................
FOUNDATION Fieldbus Type A .......................................................................................................................................
BUS Cables HMCB200, xed installed ...............................................................................................................................
BUS Cables HMCB500, Drag Chain ....................................................................................................................................
BUS Cables HMCB500S, Drag Chain ..................................................................................................................................
BUS Cables HMCB800, Drag Chain ....................................................................................................................................
BUS Cables USB S ..............................................................................................................................................................
BUS Cables USB L...............................................................................................................................................................
CAN-Bus 0,22 mm, xed installed ..................................................................................................................................
CAN-Bus 0,22 mm, xed installed ..................................................................................................................................
CAN-Bus, xed installed, 105C ........................................................................................................................................
CAN-Bus 0,34 mm, xed installed ..................................................................................................................................
CAN-Bus 0,34 mm, xed installed ..................................................................................................................................

Page
R 89
R 90
R 91
R 92
R 93
R 94
R 95
R 96
R 97
R 98
R 99
R 100
R 101
R 102
R 103
R 104
R 105
R 106
R 107
R 108
R 109
R 110
R 111
R 112
R 113
R 114
R 115
R 116
R 117
R 118
R 119
R 120
R 121
R 122
R 123
R 124
R 125
R 126
R 127
R 128
R 129
R 130
R 131
R 132
R 133
R 134
R 135
R 136

R 87
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents Bus Cables


Description
CAN-Bus 0,50 mm, xed installed ..................................................................................................................................
CAN-Bus 0,50 mm, xed installed ..................................................................................................................................
CAN-Bus 0,75 mm, xed installed ..................................................................................................................................
CAN-Bus 0,25 mm, Drag Chain .......................................................................................................................................
CAN-Bus 0,34 mm Drag Chain, UL ..................................................................................................................................
Interbus, xed installed ....................................................................................................................................................
Interbus, xed installed, halogen-free ............................................................................................................................
Interbus Drag Chain ..........................................................................................................................................................
Multibus I, high exible ....................................................................................................................................................
Multibus II, high exible....................................................................................................................................................
ASI-Bus, EPDM ...................................................................................................................................................................
ASI-Bus, PUR, UL/CSA ........................................................................................................................................................
ASI-Bus, TPE ......................................................................................................................................................................
ASI-Bus, TPE, UL/CSA.........................................................................................................................................................
AS-Interface Electrical Cabinet FLIH .................................................................................................................................
Sensor-Aktor TPM .............................................................................................................................................................
DeviceNet PVC...............................................................................................................................................................
DeviceNet FRNC ............................................................................................................................................................
DeviceNet CPE ...............................................................................................................................................................
DeviceNet PUR, exible.................................................................................................................................................
CC-Link-Bus PVC ...............................................................................................................................................................
SafetyBUS, FRNC + PUR ..................................................................................................................................................
LON BUS, H122 + Y116 ......................................................................................................................................................
EIB-Bus, 2-pairs PVC .........................................................................................................................................................
EIB-Bus, FRNC + PVC ........................................................................................................................................................
EIB-Bus ERD, PE ................................................................................................................................................................
KH-Bus, PVC + FRNC .........................................................................................................................................................

Page
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R

137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163

R 88
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Industrial Ethernet

600IND

ROBUST

S-STP, Category 7

Type
Cable structure

Industrial Area
S-STP 4x2xAWG 23/1 PUR

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 23/1)


Foam-skin-PE
wh/bu, wh/og, wh/gn, wh/bn
Double core
Polyester foil, aluminium-lined
Cu braid
PUR
approx. 8,2 mm
Green similar to RAL 6018

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 ohm at 101 to 600 MHz
148 Ohm/km max.
43 nF/km nom.

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

10
5,6
100,0
94,4

16
7,1
100,0
92,9

62,5
13,9
96,0
82,1

100
17,5
94,0
76,5

200
25,2
88,0
62,8

300
32,1
84,0
51,9

600
44,9
73,0
28,1

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 62 kg/km
85 mm
-40C
+80C
0,74 MJ/m
34,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7, Flame-retardant acc. to IEC 60332-1, Halogen-free acc. to 60754-2,
Corrosiveness acc. to EN50267-2-3, Oil-resistant

Application
HELUKAT 600IND data cables are used for harsh industrial applications. Mechanical characteristics are the steady against mineral oils, fats
and cooling lubricants. Also they are microben resistant and hydrolysis resistant. Electrically they are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. The cables thus exceed the requirements for EN55022 Class B emission and
EN55024 immunity. So this serie has a superior electromagnetic compatibility qualification.

Part no.

801197, S-STP 4x2xAWG 23/1 PUR (S/FTP)

Dimensions and specifications may be changed without prior notice.

R 89
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Industrial Ethernet

600IND

SHIPLINE

S-STP, Category 7

Cable structure

S-STP 4x2xAWG 24/7 (stranded) FRNC

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Screen over stranding element:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,61 mm
Copper, bare
Foam-skin-PE
wh/bu, wh/og, wh/gn, wh/bn
Polyester foil, aluminium-lined
Cu braid
FRNC
approx. 9,1 mm
Grey similar to RAL 7035

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 ohm at 101 to 600 MHz
164 Ohm/km max.
43 nF/km nom.
72 %

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/10m)
(db)
(db)

10
0,7
90,0
89,3

16
0,8
90,0
89,2

62,5
1,6
85,0
83,4

100
2,1
81,0
78,9

200
3,1
76,0
72,9

600
5,2
68,0
62,8

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 85 kg/km
85 mm
-20C
+75C
0,80 MJ/m
36,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3, Oil-resistant

Application
This copper data cable, designed specifically for extreme industrial applications, is the ideal solution for Ethernet applications. Superior
transmission properties, suitable for use even under the most demanding conditions, certified by Germanischer Lloyd, that means suitable
for flexible marine and offshore applications.

Part no.

803382, S-STP 4x2xAWG 24/7 FRNC (S/FTP)

Dimensions and specifications may be changed without prior notice.

R 90
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Industrial Ethernet

600IND

ROBUSTFLEX

S-STP, Category 7

Type
Cable structure

Industrial Patch Cables


S-STP 4x2xAWG 26/7 PUR

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 26/7)


Foam-skin-PE
wh/bu, wh/og, wh/gn, wh/bn
Double core
Polyester foil, aluminium-lined
Cu braid
PUR
approx. 6,4 mm
Green similar to RAL 6018

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 ohm at 101 to 600 MHz
290 Ohm/km max.
42 nF/km nom.

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(db/10m)
(db)
(db)

10
0,8
80,0
79,2

16
1,1
80,0
78,9

62,5
2,2
75,0
72,8

100
2,8
72,0
69,2

200
4,0
68,0
64,0

600
7,4
61,0
53,6

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 48 kg/km
64 mm
-40C
+80C
0,45 MJ/m
28,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7, Flame-retardant acc. to IEC 60332-1, Smoke density acc. to
IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness acc. to EN50267-2-3, Oil-resistant, AWM 20963 (80C/30V)

Application
HELUKAT600 industry data cables were designed for high requirements in the industry (industrial ethernet) and other heavy-duty environments.
They are characterized by large performance reserves and outstanding performance. Mechanically they are also perfectly suited for rough
industrial environments due to their halogen-free PUR outer sheath. These line are manufacturable with common RJ45 plugs (industry and
office version), and also with some Sub-D and M12 plugs.

Part no.

802184, S-STP 4x2xAWG 26/7 PUR (S/FTP)

Dimensions and specifications may be changed without prior notice.

R 91
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Industrial Ethernet

500IND

10GIG

S-STP, Category 6A

Cable structure

2x2x0.64 mm

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Inner sheath material:
Screen over stranding element:
Total shielding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,65 mm
Copper, bare
Foam-skin-PE
whbu/bu, whog/og, whgn/gn, whbn/bn
Polyester foil over stranded bundle
PVC
Polyester foil, aluminium-lined
Foil + braid
PVC
approx. 9,6 mm
Green similar to RAL 6018

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:
Rel. propagation velocity:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 Ohm at 101 to 500 MHz
59 Ohm/km
0,5 GOhm x km
118 Ohm/km max.
72 nF/km nom.
0,7 kV
62 %

Typical values
Frequency
Attenuation
Next
PSNext

(MHz)
(db/100m)
(dB)
(dB)

10
5,9
60,3
57,3

16
7,5
57,2
54,2

62,5
15,0
48,4
45,4

100
19,1
45,3
42,3

250
31,1
39,3
36,3

500
45,3
34,3
31,8

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 115 kg/km


80 mm
-40C
+70C
1,69 MJ/m
44,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6A,
Flame-retardant acc. to IEC 60332-3, CM 75C or PLTC

Application
Part no.

803693, INDUSTRIAL ETHERNET CAT.6A 10GIG

Dimensions and specifications may be changed without prior notice.

R 92
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Industrial Ethernet

250S

Drag Chain

S-FTP, Category 6

Cable structure

4x2x0.15 mm (stranded)

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Inner sheath material:
Screen over stranding element:
Total shielding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,55 mm
Copper, tinned
PP
whbu/bu, whog/og, whgn/gn, whbn/bn
FRNC
Foil + braid
PUR
approx. 7,8 mm
Green similar to RAL 6018

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:

100 Ohm 15 ohm at 1 to 100 MHz


100 Ohm 20 Ohm bei 101 bis 250 MHz
140 Ohm/km
0,5 GOhm x km
280 Ohm/km max.
52 nF/km nom.
0,7 kV

Typical values
Frequency
Attentuation
Next
ACR

(MHz)
(db/10m)
(db)
(db)

10
0,9
59,3
58,4

16
1,2
56,2
55,0

62,5
2,4
47,4
45,0

100
2,9
44,3
41,4

250
4,9
38,3
33,4

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 63 kg/km
60 mm
-30C
+70C
1,35 MJ/m
34,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6, Flame-retardant acc.
to IEC 60332-1, UL 1581, Sec. 1080 (VW-1) and Sec. 1060 (FT-1)

Application
This copper data cable, designed specifically for extreme industrial applications, is the ideal solution for Ethernet Category 6 applications.
Superior transmission properties, suitable for use even under the most demanding conditions, designed for use in drag chains, fire-proof
and oil-resistant according to UL/CSA, the cable can also be used in the USA and Canada.

Part no.

803387, INDUSTRIAL ETHERNET CAT.6

Dimensions and specifications may be changed without prior notice.

R 93
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Industrial Ethernet

200IND

ROBUSTFLEX

S-FTP, Category 5e

Type
Cable structure

Industrial Patch Cables


S-FTP 4x2xAWG 26/7 PUR

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 26/7)


PO
whbu/bu, whog/og, whgn/gn, whbn/bn
Double core
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid
PUR
approx. 5,7 mm
Grey similar to RAL 7035

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:

100 Ohm 15 ohm at 1 to 100 MHz


260 Ohm/km max.
47 nF/km nom.

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/10m)
(db)
(db)

10
0,8
58,0
57,2

16
1,1
56,0
54,9

62,5
2,4
45,0
42,6

100
2,9
43,0
40,1

200
4,3
37,0
32,7

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 44 kg/km
46 mm
-40C
+80C
0,54 MJ/m
24,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant acc. to IEC 60332-1, Smoke density acc. to
IEC 61034, Halogen-free acc. to 60754-2, Oil-resistant

Application
HELUKAT200 industry data cables were designed for high requirements in the industry (industrial ethernet) and other heavy-duty environments.
They are characterized by large performance reserves and outstanding performance. Mechanically they are also perfectly suited for rough
industrial environments due to their halogen-free PUR outer sheath. These lines are manufacturable with all common RJ45 plugs (industry
and office version), and also with some Sub-D and M12 plugs.

Part no.

800068, S-FTP 4x2xAWG 26/7 PUR (SF/UTP)

Dimensions and specifications may be changed without prior notice.

R 94
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Industrial Ethernet
WK Industrial 105C

S-FTP, Category 5e

Cable structure

2x2x0,75 mm (stranded)

Inner conductor diameter:


Conductor material:
Core insulation:
Core colours:
Shielding 1:
Inner sheath material:
Screen over stranding element:
Total shielding:
Outer sheath material:
Outer diameter:
Outer sheath colour:

0,75 mm
Copper, tinned
XLPE ray cross-linking
wh, ye, bu, og
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid, tinned
X-FRNC
approx. 6,5 mm
Black similar to RAL 9005

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:

100 Ohm 15 ohm at 1 to 100 MHz


60 Ohm/km
0,5 GOhm x km
120 Ohm/km max.
52 nF/km nom.
2 kV

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

10
6,3
70,0
63,7

16
8,0
65,0
57,0

62,5
16,5
55,0
38,5

100
21,3
50,0
28,7

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 64 kg/km
46 mm
-40C
+105C *
0,89 MJ/m
34,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Category 5e, Halogen-free acc. to 60754-2,
Corrosiveness acc. to EN50267-2-3, UL-Syle 21281 80C/300V

Application
This copper data cable, designed specifically for extreme industrial applications, is the ideal solution for Ethernet applications. It guarantees
superior transmission properties. Cable with oil-resistant FRNC sheath and increased temperature resistance for use in the wind turbine and
similar sectors. Certified to UL, the cable can also be used in the USA and Canada.
* = with limited service life

Part no.

802293, INDUSTRIAL ETHERNET CAT.5e

Dimensions and specifications may be changed without prior notice.

R 95
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Industrial Ethernet

100S

DRAG CHAIN ECO

S-FTP 4-Core, Category 5e

Type
Cable structure

Drag chain applications


4x1x0.15 mm (stranded)

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 26/19)


PP
whbl, bl, whor, or
Star quad
Polyester foil over stranded bundle
PETP fleece
Foil + braid
PUR
approx. 4,8 mm 0,3 mm
Green

Electrical data
Characteristic impedance:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:

100 Ohm 15 ohm at 1 to 100 MHz


0,15 GOhm x km
250 Ohm/km max.
51 nF/km nom.
0,7 kV

Typical values
Frequency
Attentuation
Next

(MHz)
(db/100m)
(db)

10
9,9
47,0

16
12,3
44,0

62,5
25,6
35,0

100
33,0
32,0

155
41,0
30,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 30 kg/km
72 mm
-40C
+80C
0,37 MJ/m
17,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant acc. to IEC 60332-1, Halogen-free acc. to 60754-2,
Corrosiveness acc. to EN50267-2-3, AWM 20963 (80C/30V)

Application
This copper data cable, designed especially for heavy-duty industrial applications (Industrial Ethernet), is very well suited for manufacturing
of RJ45 and 15 or 9-Pin Sub-D plugs. With its PUR sheath, it is also suitable for the application in drag chains.

Part no.

82838, INDUSTRIAL ETHERNET CAT.5e

Dimensions and specifications may be changed without prior notice.

R 96
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Industrial Ethernet

100S

Drag chain ECO

S-FTP 4-pair, Category 5e

Type
Cable structure

Drag chain applications


4x2x0.15 mm (stranded)

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 26/19)


PP
whbu/bu, whog/og, whgn/gn, whbn/bn
Double core
Polyester foil over stranded bundle
PETP fleece
Foil + braid
PUR
approx. 6,6 mm 0,2 mm
Green

Electrical data
Characteristic impedance:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:

100 Ohm 15 ohm at 1 to 100 MHz


0,15 GOhm x km
250 Ohm/km max.
48 nF/km nom.
0,7 kV

Typical values
Frequency
Attentuation
Next

(MHz)
(db/100m)
(db)

10
9,9
47,0

16
12,3
44,0

62,5
25,6
35,0

100
33,0
32,0

155
41,0
30,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 56 kg/km
102 mm
-40C
+80C
0,64 MJ/m
31,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant acc. to IEC 60332-1, Halogen-free acc. to 60754-2,
Corrosiveness acc. to EN50267-2-3, AWM 20963 (80C/30V)

Application
This copper data cable, designed especially for heavy-duty industrial applications (Industrial Ethernet), is very well suited for manufacturing
of RJ45 and 15 or 9-Pin Sub-D plugs. With its PUR sheath, it is also suitable for the application in drag chains.

Part no.

82839, INDUSTRIAL ETHERNET CAT.5e

Dimensions and specifications may be changed without prior notice.

R 97
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Industrial Ethernet

200S

DRAG CHAIN

S-FTP 4-Core, Category 5

Type
Cable structure

Drag Chain Patch Cables


S-FTP 4x1xAWG 24/19 PUR

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 24/19)


PP
wh/bn, gn/ye
Quad
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid
PUR
approx. 6,2 mm 0,2 mm
Green similar to RAL 6026

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:

100 Ohm 15 ohm at 1 to 100 MHz


156 Ohm/km max.
51 nF/km nom.

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/10m)
(db)
(db)

10
1,0
47,0
46,0

16
1,2
44,0
42,8

62,5
2,6
35,0
32,4

100
3,3
32,0
28,7

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 54 kg/km
80 mm
-25C
+70C
0,944 MJ/m
30,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5, Flame-retardant acc. to IEC 60332-1, Halogen-free acc. to 60754-2,
Oil-resistant

Application
HELUKAT200T industry data cables were designed for the most extreme requirements in the industry (industrial ethernet) and other
heavy-duty environments. They are characterized by large performance reserves and outstanding performance, even under the most
extreme conditions. In addition, the thought-out mechanical construction even ensures applications in drag chains with high packing density.
These lines are manufacturable with conventional Sub-D plugs or with various RJ45 plugs.

Part no.

800088, S-FTP 4x1xAWG 24/19 PUR (SF/UTP)

Dimensions and specifications may be changed without prior notice.

R 98
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Industrial Ethernet

200S

DRAG CHAIN

S-FTP 4-Paar, Category 5

Type
Cable structure

Drag Chain Patch Cables


S-FTP 4x2xAWG 24/19 PUR

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 24/19)


PE
wh/bn, gn/ye, gy/pk, bu/rd
Double core
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid
PUR
approx. 9,5 mm 0,2 mm
Green similar to RAL 6026

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:

100 Ohm 15 ohm at 1 to 100 MHz


156 Ohm/km max.
51 nF/km nom.

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/10m)
(db)
(db)

10
1,0
47,0
46,0

16
1,2
44,0
42,8

62,5
2,6
35,0
32,4

100
3,3
32,0
28,7

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 110 kg/km


115 mm
-25C
+70C
2,08 MJ/m
54,30 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5, Flame-retardant acc. to IEC 60332-1, Halogen-free acc. to 60754-2,
Oil-resistant

Application
HELUKAT200T industry data cables were designed for the most extreme requirements in the industry (industrial ethernet) and other
heavy-duty environments. They are characterized by large performance reserves and outstanding performance, even under the most
extreme conditions. In addition, the thought-out mechanical construction even ensures applications in drag chains with high packing density.
These lines are manufacturable with conventional Sub-D plugs or with various RJ45 plugs.

Part no.

81155, S-FTP 4x2xAWG 24/19 PUR (SF/UTP)

Dimensions and specifications may be changed without prior notice.

R 99
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Industrial Ethernet

100T

TORDIERFLEX

S-FTP, Category 5

Type
Cable structure

Torsion Patch Cables


S-FTP 4x2xAWG 26/19 PUR

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Screen 1 over stranding:
Screen 2 over stranding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 26/19)


PO
wh/bu, wh/og, wh/gn, wh/bn
Double core
Polyester foil over stranded bundle
Polyester foil copper, bare
Cu braid
PUR
approx. 7,5 mm
Green similar to RAL 6018

Electrical data
Characteristic impedance:
Loop resistance:
Mutual capacitance:

100 Ohm 15 ohm at 1 to 100 MHz


260 Ohm/km max.
50 nF/km nom.

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/10m)
(db)
(db)

10
1,3
47,0
45,7

16
1,6
44,0
42,4

62,5
3,2
35,0
31,8

100
4,0
32,0
28,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 63 kg/km
80 mm
-40C
+80C
1,234 MJ/m
29,50 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5, Flame-retardant acc. to IEC 60332-1, Smoke density acc. to
IEC 61034, Halogen-free acc. to 60754-2, Oil-resistant, AWM 20963 (80C/30V)

Application
HELUKAT100T TORDIERFLEX data cables were designed for the most extreme requirements in the industry and other heavy-duty environments
in torsion applications. They are characterized by large performance reserves and outstanding performance, even under extreme conditions.
Long mechanical service life is also ensured due to a thought-out design. These lines are manufacturable with conventional Sub-D plugs or
with various RJ45 plugs.

Part no.

800067, S-FTP 4x2xAWG 26/19 PUR (SF/UTP)

Dimensions and specifications may be changed without prior notice.

R 100
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Industrial Ethernet
PROFInet Type A

fixed installed + robust

Type
Cable structure

Fixed installation, indoor


2x2x0.64 mm

Industrial Area
2x2x0.64 mm

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Inner sheath material:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 22/1)


PE
wh, ye, bu, og
Star quad
Polyester foil over stranded bundle
PVC
Polyester foil, aluminium-lined
Cu braid, tinned
PVC
approx. 6,5 mm 0,2 mm
Green similar to RAL 6018

Copper, bare (AWG 22/1)


PE
wh, ye, bu, og
Star quad
Polyester foil over stranded bundle
PVC
Polyester foil, aluminium-lined
Cu braid, tinned
PUR
approx. 6,5 mm 0,2 mm
Green similar to RAL 6018

100 Ohm 15 ohm at 1 to 100 MHz


62 Ohm/km
0,5 GOhm x km
124 Ohm/km max.
50 nF/km nom.
2 kV

100 Ohm 15 ohm at 1 to 100 MHz


62 Ohm/km
0,5 GOhm x km
124 Ohm/km max.
50 nF/km nom.
2 kV

10
5,2
70,0
64,8

62,5
15,0
55,0
40,0

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

16
6,9
65,0
58,1

100
19,5
50,0
30,5

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 67 kg/km
100 mm
-40C
+80C
0,34 MJ/m
32,00 kg/km

approx. 64 kg/km
46 mm
-40C
+70C
0,91 MJ/m
32,00 kg/km

PROFInet Guideline
CMG 75C PLTC FT4
CSA FT 4

PROFInet Guideline
-

Norms
Applicable standards:
UL Style:
CSA standard:

Application
These copper data cables, designed especially for heavy-duty industrial applications, are very well suited for Ethernet applications. They
ensure superiour transmission properties and can be used even under most severe conditions. The line specified here correspond to the
PROFInet type A it is designed for normal (PVC) and robust (PUR) fixed installation applications.

Part no.

800653, PROFInet type A (SK)

801194, PROFInet type A (SK)

Dimensions and specifications may be changed without prior notice.

R 101
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Industrial Ethernet
PROFInet Type A

radiation resistant + armoured

Type

ray loaded areas

Cable structure

2x2x0.64 mm

Fixed installation,
outdoor
2x2x0.64 mm

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Inner sheath material:
Shielding 2:
Total shielding:
Armouring:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 22/1)


XLPE ray cross-linking
wh, ye, bu, og
Star quad
Polyester foil over stranded bundle
TPR ray cross-linking
Polyester foil, aluminium-lined
Cu braid, tinned
PUR
approx. 6,5 mm 0,2 mm
Green similar to RAL 6018

Copper, bare (AWG 22/1)


PE
wh, ye, bu, og
Star quad
Polyester foil over stranded bundle
PVC
Polyester foil, aluminium-lined
Cu braid, tinned
Steel rib
PE
approx. 9,3 mm 0,5 mm
Black

100 Ohm 15 ohm at 1 to 100 MHz


62 Ohm/km
0,5 GOhm x km
124 Ohm/km max.
50 nF/km nom.
2 kV

100 Ohm 15 ohm at 1 to 100 MHz


62 Ohm/km
0,5 GOhm x km
124 Ohm/km max.
50 nF/km nom.
2 kV

10
5,2
70,0
64,8

62,5
15,0
55,0
40,0

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

16
6,9
65,0
58,1

100
19,5
50,0
30,5

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 63 kg/km
46 mm
-40C
+80C
0,29 MJ/m
32,00 kg/km

approx. 124 kg/km


93 mm
-40C
+70C
2,14 MJ/m
31,00 kg/km

PROFInet Guideline

PROFInet Guideline

Norms
Applicable standards:

Application
These copper data cables, designed especially for heavy-duty industrial applications are very well suited for Ethernet applications. They ensure
superiour transmission properties and can be used even under most severe conditions. The line specified here correspond to the PROFInet
type A and because of the special construction with cross-linked inner-jacket and PUR outer-jacket it is suitable for fixed installation applications
inside radiated areas and with the PVC inner-jacket/PE outer-jacket it is suitable for areas with rodent problems.

Part no.

801195, PROFInet type A (SK)

801650, PROFInet type A (SK)

Dimensions and specifications may be changed without prior notice.

R 102
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Industrial Ethernet
PROFInet Type B

hybrid

Type
Cable structure

Mobile use
2x2x0,75 mm (stranded)+ 4x1,5 mm

Inner conductor diameter 1:


Inner conductor diameter 2:
Core insulation 1:
Core insulation 2:
Core colours 1:
Core colours 2:
Stranding element 1:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 22/7)


Copper, bare (AWG 16/84)
Foam-skin-PE
Foam-skin-PE
wh, ye, bu, og
Black
Double core
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Polyester foil
FRNC
approx. 10,3 mm 0,3 mm
Green similar to RAL 6018

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:

100 Ohm 15 ohm at 1 to 100 MHz


60 Ohm/km
0,5 GOhm x km
120 Ohm/km max.
52 nF/km nom.
2 kV

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

10
6,3
50,0
43,7

16
8,0
47,0
39,0

62,5
16,5
38,0
21,5

100
21,3
35,0
13,7

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 153 kg/km


103 mm
-40C
+70C
1,50 MJ/m
94,00 kg/km

Norms
Applicable standards:
UL Style:

PROFInet Guideline
UL Style 21282

Application
This copper data cable, designed especially for heavy-duty industrial applications is very well suited for Ethernet applications. Ir ensures
superiour transmission properties and can be used even under most severe conditions. The line specified here corresponds the PROFInet
type, i.e. it is designed for flexible applications with integrated energoe cores.

Part no.

801651, PROFInet type B (SK)

Dimensions and specifications may be changed without prior notice.

R 103
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Industrial Ethernet
PROFInet Typ B

SHIPLINE + FESTOON

Type
Cable structure

Marine and Offshore


2x2x0,75 mm (stranded)

FESTOON
2x2x0.75 mm (stranded)

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Inner sheath material:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, tinned (AWG 22/7)


PP
wh, ye, bu, og
Star quad
Polyester foil over stranded bundle
FRNC
Polyester foil, aluminium-lined
Cu braid, tinned
FRNC
approx. 6,5 mm 0,4 mm
Green similar to RAL 6018

Copper, tinned (AWG 22/7)


PE
wh, ye, bu, og
Star quad
Polyester foil over stranded bundle
PVC
Polyester foil, aluminium-lined
Cu braid, tinned
PVC
approx. 6,5 mm 0,2 mm
Green similar to RAL 6018

100 Ohm 15 ohm at 1 to 100 MHz


60 Ohm/km
0,5 GOhm x km
120 Ohm/km max.
52 nF/km nom.
2 kV

100 Ohm 5 %
60 Ohm/km
0,5 GOhm x km
120 Ohm/km max.
52 nF/km nom.
0,7 kV

10
6,0
70,0
64,0

62,5
16,0
55,0
39,0

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

16
7,6
65,0
57,4

100
21,0
50,0
29,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 68 kg/km
46 mm
-40C
+70C
0,45 MJ/m
32,00 kg/km

approx. 68 kg/km
50 mm
-10C
+80C
1,20 MJ/m
32,00 kg/km

PROFInet Guideline
CMG 75C PLTC FT4
CSA FT 4

PROFInet Guideline
CMG 75C or PLTC or AWM 21694 600V
CSA FT 4

Norms
Applicable standards:
UL Style:
CSA standard:

Application
This copper data cable, designed especially for heavy-duty industrial applications is very well suited for Ethernet applications. It ensures
superiour transmission properties and can be used even under most severe conditions. The lines specified here corresponds the PROFInet
type B and are certified by the Germanische Lloyd (SHIPLINE), i.e. designed for flexible marine and offshore applications and Festoon
applications.

Part no.

802185, PROFInet type B (SK)

803295, PROFInet type B (SK)

Dimensions and specifications may be changed without prior notice.

R 104
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Industrial Ethernet
PROFInet Type B + C

flexible + high flexible

Type
Cable structure

Mobile use
2x2x0,75 mm (stranded)

Drag chain applications


2x2x0.75 mm (stranded)

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Inner sheath material:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, tinned (AWG 22/7)


PE
wh, ye, bu, og
Star quad
Polyester foil over stranded bundle
PVC
Polyester foil, aluminium-lined
Cu braid, tinned
PVC
approx. 6,5 mm 0,2 mm
Green similar to RAL 6018

Copper, tinned (AWG 22/7)


PE
wh, ye, bu, og
Star quad
Polyester foil over stranded bundle
FRNC
Polyester foil, aluminium-lined
Cu braid, tinned
PUR
approx. 6,5 mm 0,2 mm
Green similar to RAL 6018

100 Ohm 15 ohm at 1 to 100 MHz


62 Ohm/km
0,5 GOhm x km
124 Ohm/km max.
52 nF/km nom.
2 kV

100 Ohm 15 ohm at 1 to 100 MHz


60 Ohm/km
0,5 GOhm x km
120 Ohm/km max.
52 nF/km nom.
0,7 kV

10
6,0
70,0
64,0

62,5
16,0
55,0
39,0

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(dB/100m)
(db)
(db)

16
7,6
65,0
57,4

100
21,0
50,0
29,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 67 kg/km
46 mm
-40C
+70C
0,32 MJ/m
32,00 kg/km

approx. 61 kg/km
50 mm
-40C
+70C
0,85 MJ/m
32,00 kg/km

PROFInet Guideline
CMG 60C or PLTC or AWM 20201
CSA FT 4

PROFInet Guideline
CMX 75C (shielded)
-

Norms
Applicable standards:
UL Style:
CSA standard:

Application
This copper data cable, designed especially for heavy-duty industrial applications is very well suited for Ethernet applications. Ir ensures
superiour transmission properties and can be used even under most severe conditions. The lines specified here corresponds the PROFInet
types B and C, i.e. they are designed for flexible and highly flexible applications, such as drag chains.

Part no.

800654, PROFInet type B (SK)

800655, PROFInet type C (SK)

Dimensions and specifications may be changed without prior notice.

R 105
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Industrial Ethernet
PROFInet Type C

Torsion

Type
Cable structure

Torsional applications
2x2x0,75 mm (stranded)

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, tinned (AWG 22/19)


Foam-skin-PE
wh, ye, bu, og
Star quad
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid, tinned
PUR
approx. 6,5 mm 0,2 mm
Green similar to RAL 6018

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:

100 Ohm 15 ohm at 1 to 100 MHz


60 Ohm/km
0,5 GOhm x km
120 Ohm/km max.
52 nF/km nom.
0,7 kV

Typical values
Frequency
Attenuation
ELFEXT

(MHz)
(db/100m)
(db)

10
7,6
43,8

16
10,0
39,7

62,5
26,5
24,0

100
41,0
20,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 54 kg/km
46 mm
-40C
+80C
0,45 MJ/m
32,00 kg/km

Norms
Applicable standards:
UL Style:

PROFInet Guideline
AWM Style 21161 80C

Application
This copper data cable, designed especially for heavy-duty industrial applications is very well suited for Ethernet applications. Ir ensures
superiour transmission properties and can be used even under most severe conditions. The lines specified here corresponds the PROFInet
types C, i.e. they are designed for torsion applications, such as roboter arms.

Part no.

802186, PROFInet type C (SK)

Dimensions and specifications may be changed without prior notice.

R 106
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
Profibus L2

Indoor

Type
Cable structure

Fixed installation, indoor


1x2x0.64 mm

Fixed installation, indoor


1x2x0.64 mm

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 22/1)


Foam-skin-PE
rd, gn
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid, tinned
PVC
approx. 7,8 mm 0,2 mm
Grey similar to RAL 7001

Copper, bare (AWG 22/1)


Foam-skin-PE
rd, gn
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid, tinned
PVC
approx. 7,8 mm 0,2 mm
Violet similar to RAL 4001

150 Ohm 10 %
55 Ohm/km
1 GOhm x km
110 Ohm/km max.
30 nF/km nom.
1,5 kV
9,6
kHz < 2,5
38,4 kHz < 4,0
4
MHz < 22,0
16
MHz < 42,0

150 Ohm 10 %
55 Ohm/km
1 GOhm x km
110 Ohm/km max.
30 nF/km nom.
1,5 kV
9,6
kHz < 2,5
38,4 kHz < 4,0
4
MHz < 22,0
16
MHz < 42,0

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:
Attenuation:

dB/km
dB/km
dB/km
dB/km

dB/km
dB/km
dB/km
dB/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 69 kg/km
120 mm
-40C
+70C
0,99 MJ/m
24,00 kg/km

approx. 69 kg/km
120 mm
-40C
+70C
0,99 MJ/m
24,00 kg/km

Profibus acc. to DIN 19245 T3 and EN50170


CMX 75C (shielded)
CSA FT1

Profibus acc. to DIN 19245 T3 and EN50170


CMX 75C (shielded)
CSA FT1

Norms
Applicable standards:
UL Style:
CSA standard:

Application
This system cable is used to interconnect L2-BUS components. This cable is an economical solution for the cell and field area. For the
information exchange between different automation systems as well as for communication with the connected decentralized field units,
serial field bus systems are used. The types mentioned here are suitable for indoor laying and are equipped with a special PVC sheath.

Part no.

80384, Profibus L2

81448, Profibus L2

Dimensions and specifications may be changed without prior notice.

R 107
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
PROFIBUS L2 Outdoor + Industry

Type

Outdoor + Industry

Cable structure

Fixed installation,
outdoor
1x2x0.64 mm

Industrial Area
1x2x0.64 mm

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 22/1)


Foam-skin-PE
rd, gn
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid, tinned
PE
approx. 8,0 mm 0,4 mm
Black similar to RAL 9005

Copper, bare (AWG 22/1)


Foam-skin-PE
rd, gn
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid, tinned
PUR
approx. 8,0 mm 0,4 mm
Petrol similar to RAL 5018

150 Ohm 10 %
55 Ohm/km
1 GOhm x km
110 Ohm/km max.
30 nF/km nom.
1,5 kV
9,6
kHz < 2,5
38,4 kHz < 4,0
4
MHz < 22,0
16
MHz < 42,0

150 Ohm 10 %
55 Ohm/km
1 GOhm x km
110 Ohm/km max.
30 nF/km nom.
1,5 kV
9,6
kHz < 2,5
38,4 kHz < 4,0
4
MHz < 22,0
16
MHz < 42,0

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:
Attenuation:

dB/km
dB/km
dB/km
dB/km

dB/km
dB/km
dB/km
dB/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 64 kg/km
120 mm
-40C
+70C
2,26 MJ/m
24,00 kg/km

approx. 67 kg/km
120 mm
-40C
+70C
1,52 MJ/m
24,00 kg/km

Profibus acc. to DIN 19245 T3 and EN50170

Profibus acc. to DIN 19245 T3 and EN50170

Norms
Applicable standards:

Application
This system cable is used to interconnect L2-BUS components. This cable is an economical solution for the cell and field area. For the
information exchange between different automation systems as well as for communication with the connected decentralized field units,
serial field bus systems are used. The types mentioned here are suitable for outdoor laying (PE sheath) and industry laying (PUR sheath).

Part no.

80792, Profibus L2

81186, Profibus L2

Dimensions and specifications may be changed without prior notice.

R 108
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
Profibus L2 Direct Burial

without + with Armouring

Type
Cable structure

Underground laying
1x2x0.64 mm

Underground laying
1x2x0.64 mm

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Inner sheath material:
Shielding 2:
Total shielding:
Armouring:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 22/1)


Foam-skin-PE
rd, gn
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
PVC
Polyester foil, aluminium-lined
Cu braid, tinned
PE
approx. 10,0 mm 0,2 mm
Black similar to RAL 9005

Copper, bare (AWG 22/1)


Cell PE
rd, gn
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
PE
Polyester foil, aluminium-lined
Cu braid, tinned
Steel band
PE
approx. 10,6 mm 0,3 mm
Black similar to RAL 9005

150 Ohm 10 %
55 Ohm/km
1 GOhm x km
114 Ohm/km max.
30 nF/km nom.
1,5 kV
9,6
kHz < 2,5
38,4 kHz < 4,0
3
MHz < 22,0
20
MHz < 42,0

150 Ohm 10 %
55 Ohm/km
5 GOhm x km
110 Ohm/km max.
30 nF/km nom.
250 V
1,5 kV
9,6
kHz < 2,5
38,4 kHz < 4,0
4
MHz < 22,0
16
MHz < 42,0

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Nominal voltage:
Test voltage:
Attenuation:

dB/km
dB/km
dB/km
dB/km

dB/km
dB/km
dB/km
dB/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 92 kg/km
180 mm
-40C
+70C
2,657 MJ/m
24,00 kg/km

approx. 132 kg/km


190 mm
-40C
+70C
2,40 MJ/m
24,00 kg/km

Profibus acc. to DIN 19245 T3 and EN50170

Profibus acc. to DIN 19245 T3 and EN50170

Norms
Applicable standards:

Application
This system cable is used to interconnect L2-BUS components. This cable is an economical solution for the cell and field area. For the
information exchange between different automation systems as well as for communication with the connected decentralized field units,
serial field bus systems are used. The above mentioned type is suitable for underground installation and is equipped with a special PVC/PE
sheath.

Part no.

82824, Profibus ERD

802177, Profibus L2

Dimensions and specifications may be changed without prior notice.

R 109
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
Profibus L2

7-wire

Type
Cable structure

Mobile use
1x2x0.64 mm (stranded)

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 24/7)


Foam-skin-PE
rd, gn
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid, tinned
PVC
approx. 7,8 mm 0,2 mm
Violet similar to RAL 4001

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:
Attenuation:

150 Ohm 10 %
86,7 Ohm/km
1 GOhm x km
110 Ohm/km max.
30 nF/km nom.
1,5 kV
9,6
kHz < 3,0
38,4 kHz < 5,0
4
MHz < 26,0
16
MHz < 55,0

dB/km
dB/km
dB/km
dB/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 75 kg/km
120 mm
-20C
+70C
1,20 MJ/m
24,00 kg/km

Norms
Applicable standards:
UL Style:

Profibus acc. to DIN 19245 T3 and EN50170


UL Style 2571

Application
This system cable is used to interconnect L2-BUS components. This cable is an economical solution for the cell and field area. For the
information exchange between different automation systems as well as for communication with the connected decentralized field units,
serial field bus systems are used. With his cord design, the type mentioned here is suitable for laying in regular mobile applications and is
equipped with a special PVC sheath.

Part no.

800648, Profibus L2

Dimensions and specifications may be changed without prior notice.

R 110
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
Profibus L2

Drag Chain

Type
Cable structure

Drag chain applications


1x2x0.64 mm (stranded)

Drag chain applications


1x2x0.64 mm (stranded)

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 24/19)


Foam-skin-PE
rd, gn
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid, tinned
PUR
approx. 8,0 mm 0,4 mm
Petrol similar to RAL 5018

Copper, bare (AWG 24/19)


Foam-skin-PE
rd, gn
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid, tinned
PUR
approx. 8,0 mm 0,4 mm
Violet similar to RAL 4001

150 Ohm 10 %
82 Ohm/km
1 GOhm x km
164 Ohm/km max.
30 nF/km nom.
1,5 kV
9,6
kHz < 3,0
38,4 kHz < 5,0
4
MHz < 25,0
16
MHz < 52,0

150 Ohm 10 %
82 Ohm/km
1 GOhm x km
164 Ohm/km max.
30 nF/km nom.
1,5 kV
9,6
kHz < 3,0
38,4 kHz < 5,0
4
MHz < 25,0
16
MHz < 52,0

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:
Attenuation:

dB/km
dB/km
dB/km
dB/km

dB/km
dB/km
dB/km
dB/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 65 kg/km
60 mm
-20C
+60C
1,52 MJ/m
25,00 kg/km

approx. 65 kg/km
60 mm
-20C
+60C
1,52 MJ/m
25,00 kg/km

Profibus acc. to DIN 19245 T3 and EN50170

Profibus acc. to DIN 19245 T3 and EN50170

Norms
Applicable standards:

Application
This system cable is used to interconnect L2-BUS components. This cable is an economical solution for the cell and field area. For the
information exchange between different automation systems as well as for communication with the connected decentralized field units,
serial field bus systems are used. The above mentioned types are suitable for drag chains (stranded).

Part no.

81003, Profibus L2

80267, Profibus L2

Dimensions and specifications may be changed without prior notice.

R 111
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
Profibus

ET200X + ECOFAST

Type
Cable structure

Drag chain applications


Drag chain applications
1x2x0.65 mm +
1x2x0.65 mm +
3x1x0.75 mm (stranded) 4x1x1.5 mm (stranded)

Inner conductor diameter 1:


Inner conductor diameter 2:
Core insulation 1:
Core insulation 2:
Core colours 1:
Core colours 2:
Stranding element 1:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 22/19)


Copper, bare (AWG 18/24)
Foam-skin-PE
PVC
rd, gn
bk, bu, gnye
Double core
Polyester foil over stranded bundle
Foil + braid
Polyester foil
PUR
approx. 9,5 mm 0,5 mm
Petrol similar to RAL 5018

Copper, bare (AWG 24/19)


Copper, bare (AWG 18/84)
Foam-skin-PE
TPM
rd, gn
bk, bk, bk, bk
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
Foil + braid
TPU
approx. 11,0 mm 0,3 mm
Violet similar to RAL 4001

150 Ohm 10 %
84 Ohm/km
1 GOhm x km
168 Ohm/km max.
30 nF/km nom.
1,5 kV
9,6
kHz < 3,0
38,4 kHz < 5,0
4
MHz < 25,0
16
MHz < 52,0

150 Ohm 15 %
89,9 Ohm/km
1 GOhm x km
179 Ohm/km max.
30 nF/km nom.
1,5 kV
9,6
kHz 3,0
38,4 kHz 5,0
4
MHz 30,0
16
MHz 60,0

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:
Attenuation:

dB/Km
dB/Km
dB/Km
dB/Km

dB/km
dB/km
dB/km
dB/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 105 kg/km


140 mm
-5C
+60C
1,973 MJ/m
46,00 kg/km

approx. 159 kg/km


165 mm
-20C
+60C
2,835 MJ/m
90,00 kg/km

Profibus acc. to DIN 19245 T3 and EN50170


AWM Style 20351

Profibus acc. to DIN 19245 T3 and EN50170


UL Style 20233

Norms
Applicable standards:
UL Style:

Application
The Profibus-ET200X and Profibus ECOFAST lines used in the area of process automation. These BUS systems are a very economical solution
for the cell and field area. For the information exchange between different automation systems as well as for communication with the
connected decentralized field units, serial field bus systems are used. The series ET200X and DESINA hybrid are characterized by a special
construction with data and power supply in one cable. These types are suited for the application in drag chains and similar mobile applications.

Part no.

82913, Profibus L2

800044, Profibus L2

Dimensions and specifications may be changed without prior notice.

R 112
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Bus Cables
Profibus

SHIPLINE and High Temperature

Type
Cable structure

Marine and Offshore


1x2x0.75 mm (stranded)

High temperature areas


1x2x0.64 mm

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Inner sheath material:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 22/7)


Foam-skin-PE
rd, gn
Double core
Polyester foil over stranded bundle
FRNC
Polyester foil, aluminium-lined
Cu braid, tinned
X-FRNC
approx. 8,0 mm 0,4 mm
Violet similar to RAL 4001

Copper, bare (AWG 22/1)


XLPE ray cross-linking
rd, gn
2 cores + 2 fillers stranded together
Polyester foil, aluminium-lined
Cu braid, tinned
FEP
approx. 7,2 mm 0,3 mm
Violet similar to RAL 4001

150 Ohm 10 %
55 Ohm/km
1,6 GOhm x km
110 Ohm/km max.
29 nF/km nom.
60 V
1 kV
9,6
kHz < 2,5
38,4 kHz < 4,0
4
MHz < 22,0
16
MHz < 42,0

150 Ohm 10 %
55 Ohm/km
1,6 GOhm x km
110 Ohm/km max.
28 nF/km nom.
250 V
3,6 kV
9,6
kHz < 2,5
38,4 kHz < 4,0
4
MHz < 22,0
16
MHz < 42,0

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Nominal voltage:
Test voltage:
Attenuation:

dB/Km
dB/Km
dB/Km
dB/Km

dB/km
dB/km
dB/km
dB/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 84 kg/km
80 mm
-25C
+80C
1,26 MJ/m
35,00 kg/km

approx. 64 kg/km
52 mm
-50C
+180C
0,30 MJ/m
24,00 kg/km

Profibus acc. to DIN 19245 T3 and EN50170

Profibus acc. to DIN 19245 T3 and EN50170

Norms
Applicable standards:

Application
The series SHIPLINE and HIGH TEMPERATURE are used to interconnect Profibus components. For the information exchange between different
automation systems as well as for communication with the connected decentralized field units, serial field bus systems are used. The lines
described here are designed for Marine and Offshore applications or the use in extreme temperature ranges.

Part no.

802178, Profibus SHIPLINE

802179, Profibus high temperature

Dimensions and specifications may be changed without prior notice.

R 113
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
DESINA-HYBRID-BUS

Type
Cable structure

Hybrid Bus Cable


4x1.5 mm + 2xPOF

Conductor material
Core insulation:
Polymer optical fibre:
Core colours:
Core identification:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare, KL.6 = extra fine wire


TPM
4x POF 980/1000
Black
Numbers
PETP fleece
TPU
approx. 8,8 mm 0,3 mm
Violet similar to RAL 4001

Electrical data
Conductor resistance, max.:
Insulation resistance, min.:
Test voltage:

13,7 Ohm/km
0,5 GOhm x km
3 kV

Optical characteristic
Fibre attenuation:

230 dB/km max. at 650 nm

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 120 kg/km


130 mm
-20C
+80C
60,00 kg/km

Norms
Applicable standards:

Detail specification for DESINA

Application
The DESINA Cu/POF hybrid field bus cables combines signal lines made of plastic fibre-optic conductors and copper cables. The use of these
transmission systems significantly reduces the number of different cables in a planned bus installation in machine tools operations. The
main applications of these cables are in mobile applications in machine construction.

Part no.

81713, DESINA HYBRID BUS

Dimensions and specifications may be changed without prior notice.

R 114
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
Profibus L2

TORSION + FESTOON

Type
Cable structure

Torsional applications
1x2x0.80 mm (stranded)

Mobile use
1x2x0.65 mm (stranded)

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 22/19)


Foam-skin-PE
rd, gn
2 cores + filler
Polyester foil, aluminium-lined
Cu braid, tinned
PUR
approx. 8,0 mm 0,4 mm
Violet similar to RAL 4001

Copper, bare (AWG 24/19)


Cell PE
rd, gn
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid, tinned
PVC
approx. 8,0 mm 0,3 mm
Petrol similar to RAL 5018

150 Ohm 10 %
49 Ohm/km
1 GOhm x km
98 Ohm/km max.
29 nF/km nom.
3,6 kV
9,6
kHz < 3,0
38,4 kHz < 5,0
4
MHz < 25,0
16
MHz < 51,0

150 Ohm 10 %
66,5 Ohm/km
1,6 GOhm x km
133 Ohm/km max.
28 nF/km nom.
2 kV
9,6
kHz 3,0
38,4 kHz 4,0
4
MHz 25,0
16
MHz 49,0

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:
Attenuation:

dB/km
dB/km
dB/km
dB/km

dB/km
dB/km
dB/km
dB/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 66 kg/km
100 mm
-25C
+75C
0,89 MJ/m
32,00 kg/km

approx. 64 kg/km
40 mm
-40C
+60C
1,09 MJ/m
23,00 kg/km

Profibus acc. to DIN 19245 T3 and EN50170


CMX 75C (shielded)
-

Profibus acc. to DIN 19245 T3 and EN50170


CMG 75C or CL2 or AWM 20201 600V
CSA FT 4

Norms
Applicable standards:
UL Style:
CSA standard:

Application
The series TORSION and FESTOON are used to interconnect Profibus BUS components. This BUS system is a very economical solution for the
field area. For the information exchange between different automation systems as well as for communication with the connected decentralized
field units, serial field bus systems are used. The lines described here are designed torsionable or hanging movable construction. Areas such
as robot applications and/or garland suspension are easily realized.

Part no.

800109, Profibus L2

800649, Profibus L2

Dimensions and specifications may be changed without prior notice.

R 115
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
Profibus PA

Type
Cable structure

Hazardous areas
1x2x1.0/2.55 mm

Non-hazardous areas
1x2x1.0/2.55 mm

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 18/1)


PE
rd, gn
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid, tinned
PVC
approx. 7,6 mm 0,2 mm
Blue

Copper, bare (AWG 18/1)


PE
rd, gn
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid, tinned
PVC
approx. 7,6 mm 0,2 mm
Black

100 Ohm 20 %
22 Ohm/km
1 GOhm x km
44 Ohm/km max.
55 nF/km nom.
300 V
2,5 kV
39
kHz 3,0

100 Ohm 20 %
22 Ohm/km
1 GOhm x km
44 Ohm/km max.
55 nF/km nom.
300 V
2,5 kV
39
kHz 3,0

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Nominal voltage:
Test voltage:
Attenuation:

dB/km

dB/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 76 kg/km
140 mm
-20C
+70C
0,95 MJ/m
44,00 kg/km

approx. 76 kg/km
140 mm
-20C
+70C
0,95 MJ/m
44,00 kg/km

Profibus acc. to DIN 19245 T3 and EN50170


UL Style 2571

Profibus acc. to DIN 19245 T3 and EN50170


UL Style 2571

Norms
Applicable standards:
UL Style:

Application
This Profibus PA line is used in the area of process automation, among other things in the chemical industry. This cable is an economical
solution for the cell and field area. For the information exchange between different automation systems as well as for communication with
the connected decentralized field units, serial field bus systems are used. The above mentioned types are suitable for ex (and ATEX/ Class
II, EX-i/ EN 60079-14) and not-ex installation and are equipped with a special PVC-sheath.

Part no.

82835, Profibus PA

82836, Profibus PA

Dimensions and specifications may be changed without prior notice.

R 116
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Bus Cables
Profibus PA

armoured

Type
Cable structure

Hazardous areas
1x2x1.0/2.55 mm

Non-hazardous areas
1x2x1.0/2.55 mm

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Inner sheath material:
Shielding 2:
Total shielding:
Armouring:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 18/1)


PE
rd, gn
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
PVC
Polyester foil, aluminium-lined
Cu braid, tinned
Steel band
PVC
approx. 10,2 mm 0,2 mm
Blue

Copper, bare (AWG 18/1)


PE
rd, gn
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
PVC
Polyester foil, aluminium-lined
Cu braid, tinned
Steel band
PVC
approx. 10,2 mm 0,2 mm
Black

100 Ohm 15 %
22 Ohm/km
1 GOhm x km
44 Ohm/km max.
55 nF/km nom.
300 V
2,5 kV
39
kHz 3,0

100 Ohm 15 %
22 Ohm/km
1 GOhm x km
44 Ohm/km max.
55 nF/km nom.
300 V
2,5 kV
39
kHz 3,0

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Nominal voltage:
Test voltage:
Attenuation:

dB/km

dB/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 170 kg/km


200 mm
-20C
+70C
1,95 MJ/m
45,00 kg/km

approx. 170 kg/km


200 mm
-20C
+70C
1,95 MJ/m
45,00 kg/km

Profibus acc. to DIN 19245 T3 and EN50170

Profibus acc. to DIN 19245 T3 and EN50170

Norms
Applicable standards:

Application
This Profibus PA line is used in the area of process automation, among other things in the chemical industry. This cable is an economical
solution for the cell and field area. For the information exchange between different automation systems as well as for communication with
the connected decentralized field units, serial field bus systems are used. The above mentioned types are suitable for ex and not-ex installation
where rodent infestation is to be expected and therefore equipped with a metal armouring and a double PVC-sheath.

Part no.

802180, Profibus PA

802181, Profibus PA

Dimensions and specifications may be changed without prior notice.

R 117
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
Profibus PA

Long Distance

Type
Cable structure

Hazardous areas
1x2x1.6/3.2 mm

Non-hazardous areas
1x2x1.6/3.2 mm

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 16/7)


PE
rd, gn
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid, tinned
PVC
approx. 9,5 mm 0,5 mm
Blue

Copper, bare (AWG 16/7)


PE
rd, gn
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid, tinned
PVC
approx. 9,5 mm 0,5 mm
Black

100 Ohm 20 %
24 Ohm/km
1 GOhm x km
48 Ohm/km max.
60 nF/km nom.
300 V
1 kV
39
kHz 2,7

100 Ohm 20 %
24 Ohm/km
1 GOhm x km
48 Ohm/km max.
60 nF/km nom.
300 V
1 kV
39
kHz 2,7

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Nominal voltage:
Test voltage:
Attenuation:

dB/km

dB/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 110 kg/km


75 mm
-40C
+70C
1,57 MJ/m
62,00 kg/km

approx. 110 kg/km


75 mm
-40C
+70C
1,57 MJ/m
62,00 kg/km

Profibus acc. to DIN 19245 T3 and EN50170


UL Style 2571

Profibus acc. to DIN 19245 T3 and EN50170


UL Style 2571

Norms
Applicable standards:
UL Style:

Application
This Profibus PA line is used in the area of process automation, among other things in the chemical industry. This cable is an economical
solution for the cell and field area. For the information exchange between different automation systems as well as for communication with
the connected decentralized field units, serial field bus systems are used. The types mentioned here are suitable for ex and not-ex installation
and are equipped with a special PVC-sheath.

Part no.

800650, Profibus PA

800715, Profibus PA

Dimensions and specifications may be changed without prior notice.

R 118
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
Profibus SK

Indoor + Outdoor

Type

Fixed installation, indoor

Cable structure

1x2x0.64 mm

Fixed installation,
outdoor
1x2x0.64 mm

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Inner sheath material:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 22/1)


Foam-skin-PE
rd, gn
Double core
Polyester foil over stranded bundle
PVC
Polyester foil, aluminium-lined
Cu braid, tinned
PVC
approx. 8,0 mm 0,4 mm
Violet similar to RAL 4001

Copper, bare (AWG 22/1)


Foam-skin-PE
rd, gn
Double core
Polyester foil over stranded bundle
PE
Polyester foil, aluminium-lined
Cu braid, tinned
PE
approx. 8,0 mm 0,4 mm
Black similar to RAL 9005

150 Ohm 10 %
55 Ohm/km
1 GOhm x km
110 Ohm/km max.
35 nF/km nom.
1,5 kV
9,6
kHz < 2,5
38,4 kHz < 4,0
4,0
MHz < 22,0
16,0 MHz < 42,0

150 Ohm 10 %
55 Ohm/km
1 GOhm x km
110 Ohm/km max.
35 nF/km nom.
1,5 kV
9,6
kHz < 2,5
38,4 kHz < 4,0
4
MHz < 22,0
16
MHz < 42,0

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:
Attenuation:

dB/km
dB/km
dB/km
dB/km

dB/km
dB/km
dB/km
dB/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 79 kg/km
120 mm
-40C
+80C
1,068 MJ/m
24,00 kg/km

approx. 65 kg/km
120 mm
-20C
+70C
1,451 MJ/m
24,00 kg/km

Profibus acc. to DIN 19245 T3 and EN50170


CMG 75C or CL3 or AWM 21694 600V
CSA FT 4

Profibus acc. to DIN 19245 T3 and EN50170


-

Norms
Applicable standards:
UL Style:
CSA standard:

Application
The application of these Profibus SK cables are in the cell and field area, just as for conventional types. The great advantage of this new
system is the quick connection of the cable to the respective plugs. This type of processing also avoids errors. The above mentioned types
are suitable for indoor- or outdoor installation and are equipped with a special PVC or PE sheath.

Part no.

81903, Profibus SK

81904, Profibus SK

Dimensions and specifications may be changed without prior notice.

R 119
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
Profibus SK

FRNC + Industry

Type
Cable structure

Fixed installation, indoor


1x2x0.64 mm

Industrial Area
1x2x0.64 mm

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Inner sheath material:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 22/1)


Foam-skin-PE
rd, gn
Double core
Polyester foil over stranded bundle
FRNC
Polyester foil, aluminium-lined
Cu braid, tinned
FRNC
approx. 8,0 mm 0,4 mm
Violet similar to RAL 4001

Copper, bare (AWG 22/1)


Foam-skin-PE
rd, gn
Double core
Polyester foil over stranded bundle
PE
Polyester foil, aluminium-lined
Cu braid, tinned
PUR
approx. 8,0 mm 0,4 mm
Violet similar to RAL 4001

150 Ohm 10 %
55 Ohm/km
1 GOhm x km
110 Ohm/km max.
35 nF/km nom.
1,5 kV
9,6
kHz < 2,5
38,4 kHz < 4,0
4
MHz < 22,0
16
MHz < 42,0

150 Ohm 10 %
55 Ohm/km
1 GOhm x km
110 Ohm/km max.
35 nF/km nom.
1,5 kV
9,6
kHz < 2,5
38,4 kHz < 4,0
4
MHz < 22,0
16
MHz < 42,0

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:
Attenuation:

dB/km
dB/km
dB/km
dB/km

dB/km
dB/km
dB/km
dB/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 73 kg/km
160 mm
-25C
+70C
1,203 MJ/m
24,00 kg/km

approx. 71 kg/km
120 mm
-40C
+70C
1,574 MJ/m
24,00 kg/km

Profibus acc. to DIN 19245 T3 and EN50170


CM 750C (shielded)
-

Profibus acc. to DIN 19245 T3 and EN50170


AWM Style 20236 AWM I/II A/B 80C 30V FT1
CSA FT1

Norms
Applicable standards:
UL Style:
CSA standard:

Application
The application of these Profibus SK cables are in the cell and field area, just as for conventional types. The great advantage of this new
system is the quick connection of the cable to the respective plugs. This type of processing also avoids errors. The types mentioned here
are suitable for indoor laying (special FRNC sheath) and heay industry laying (PUR sheath).

Part no.

81501, Profibus SK

81905, Profibus SK

Dimensions and specifications may be changed without prior notice.

R 120
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
Profibus SK

Drag Chain

Type
Cable structure

Drag chain applications


1x2x0.64 mm (stranded)

Drag chain applications


1x2x0.64 mm (stranded)

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Inner sheath material:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 24/19)


Foam-skin-PE
rd, gn
Double core
Polyester foil over stranded bundle
PVC
Polyester foil, aluminium-lined
Cu braid, tinned
PUR
approx. 8,0 mm 0,4 mm
Petrol similar to RAL 5018

Copper, bare (AWG 24/19)


Foam-skin-PE
rd, gn
Double core
Polyester foil over stranded bundle
PVC
Polyester foil, aluminium-lined
Cu braid, tinned
PUR
approx. 8,0 mm 0,4 mm
Violet similar to RAL 4001

150 Ohm 10 %
84 Ohm/km
1 GOhm x km
168 Ohm/km max.
35 nF/km nom.
1,5 kV
9,6
kHz < 3,0
38,4 kHz < 5,0
4
MHz < 25,0
16
MHz < 52,0

150 Ohm 10 %
84 Ohm/km
1 GOhm x km
168 Ohm/km max.
35 nF/km nom.
1,5 kV
9,6
kHz < 3,0
38,4 kHz < 5,0
4
MHz < 25,0
16
MHz < 52,0

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:
Attenuation:

dB/km
dB/km
dB/km
dB/km

dB/km
dB/km
dB/km
dB/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 70 kg/km
60 mm
-40C
+70C
1,53 MJ/m
25,00 kg/km

approx. 70 kg/km
60 mm
-40C
+70C
1,53 MJ/m
25,00 kg/km

Profibus acc. to DIN 19245 T3 and EN50170


CMX 75C (shielded)
CSA FT1

Profibus acc. to DIN 19245 T3 and EN50170


CMX 75C (shielded)
CSA FT1

Norms
Applicable standards:
UL Style:
CSA standard:

Application
The application of these Profibus SK cables are in the cell and field area, just as for conventional types. The great advantage of this new
system is the quick connection of the cable to the respective plugs. This type of processing also avoids errors. The above mentioned types
are suitable for drag chains (stranded).

Part no.

81906, Profibus SK

801659, Profibus SK

Dimensions and specifications may be changed without prior notice.

R 121
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
FOUNDATION Fieldbus

Basic

Type
Cable structure

process automation
1x2x1.1/2,55-100 LI

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Drain wire:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 18/7)


PO
or, bl
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid, tinned
yes
PVC
approx. 8,0 mm 0,3 mm
Orange

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Nominal voltage:
Test voltage:
Attenuation:

100 Ohm 20 Ohm


22 Ohm/km
5 GOhm x km
44 Ohm/km max.
60 nF/km nom.
300 V
1,5 kV
39
kHz 3,4

dB/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 85 kg/km
80 mm
-40C
+80C
1,22 MJ/m
45,00 kg/km

Norms
Applicable standards:
UL Style:
CSA standard:

Foundation Fieldbus Spec. FF-816-1.4


CMG 75C PLTC FT4
CSA FT 4

Application
The FOUNDATION Fieldbus is an open and neutral fieldbus standard which is primarily oriented on the requirements of process automation.
It is a functionally complete fieldbus solution for areas like temperature transmitters, pressure transmitters or valve actuators. Today we
distinguish between the specification H1 (31,25 kbit/s) and HSE (100Mbit/s). Branches like the petrochemical, chemical or the food- and
beverage industry see the advantages and use the FOUNDATION fieldbus technology.

Part no.

803354, Foundation Fieldbus Basic

Dimensions and specifications may be changed without prior notice.

R 122
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
FOUNDATION Fieldbus

Type A + gnye

Type
Cable structure

process automation
1x2x1.1/2,85-100 LI + 1x0,8 gnye

Inner conductor diameter 1:


Inner conductor diameter 2:
Core insulation 1:
Core insulation 2:
Core colours 1:
Core colours 2:
Stranding element 1:
Shielding 1:
Shielding 2:
Total shielding:
Drain wire:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 18/41)


Copper, bare (AWG 18/41)
XLPE ray cross-linking
PVC
bu, bn
gn/ye
Double core
Polyester foil, aluminium-lined
Cu braid, tinned
yes
PVC
approx. 7,9 mm 0,3 mm
Yellow

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Nominal voltage:
Test voltage:
Attenuation:

100 Ohm 20 Ohm


24 Ohm/km
2 GOhm x km
48 Ohm/km max.
65 nF/km nom.
300 V
1,5 kV
39
kHz 3,4

dB/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 84 kg/km
60 mm
-25C
+105C
1,00 MJ/m
49,00 kg/km

Norms
Applicable standards:
UL Style:
CSA standard:

Foundation Fieldbus Spec. FF-816-1.4


CMG 105 or CL3 FT4
CSA FT 4

Application
The FOUNDATION Fieldbus is an open and neutral fieldbus standard which is primarily oriented on the requirements of process automation.
It is a functionally complete fieldbus solution for areas like temperature transmitters, pressure transmitters or valve actuators. Today we
distinguish between the specification H1 (31,25 kbit/s) and HSE (100Mbit/s). Branches like the petrochemical, chemical or the food- and
beverage industry see the advantages and use the FOUNDATION fieldbus technology.

Part no.

801191 ,Foundation Fieldbus FF A

Dimensions and specifications may be changed without prior notice.

R 123
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
FOUNDATION Fieldbus

Type A armoured

Type
Cable structure

process automation
1x2x1.1/2,85-100 LI + 1x0,8 gnye, armoured

Inner conductor diameter 1:


Inner conductor diameter 2:
Core insulation 1:
Core insulation 2:
Core colours 1:
Core colours 2:
Stranding element 1:
Shielding 1:
Shielding 2:
Total shielding:
Drain wire:
Armouring:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 18/41)


Copper, bare (AWG 18/41)
XLPE ray cross-linking
PVC
bu, bn
gn/ye
Double core
Polyester foil, aluminium-lined
Polyester foil, aluminium-lined
yes
Steel shaft
PVC
approx. 12,3 mm 0,3 mm
Yellow

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Nominal voltage:
Test voltage:
Attenuation:

100 Ohm 20 Ohm


24 Ohm/km
2 GOhm x km
48 Ohm/km max.
65 nF/km nom.
300 V
1,5 kV
39
kHz 3,4

dB/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 187 kg/km


130 mm
-25C
+105C
1,65 MJ/m
110,00 kg/km

Norms
Applicable standards:
UL Style:
CSA standard:

Foundation Fieldbus Spec. FF-816-1.4


CMG 105C or PLTC FT4 Sun Res
CSA FT 4

Application
The FOUNDATION Fieldbus is an open and neutral fieldbus standard which is primarily oriented on the requirements of process automation.
It is a functionally complete fieldbus solution for areas like temperature transmitters, pressure transmitters or valve actuators. Today we
distinguish between the specification H1 (31,25 kbit/s) and HSE (100Mbit/s). Branches like the petrochemical, chemical or the food- and
beverage industry see the advantages and use the FOUNDATION fieldbus technology.

Part no.

801192, Foundation Fieldbus FF A

Dimensions and specifications may be changed without prior notice.

R 124
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
FOUNDATION Fieldbus

Type A

Type
Cable structure

process automation
1x2x1.1/2,85-100 LI

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Drain wire:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 18/41)


XLPE ray cross-linking
bu, bn
Double core
Polyester foil, aluminium-lined
Cu braid, tinned
yes
PVC
approx. 7,9 mm 0,3 mm
Yellow

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Nominal voltage:
Test voltage:
Attenuation:

100 Ohm 20 Ohm


24 Ohm/km
2 GOhm x km
48 Ohm/km max.
65 nF/km nom.
300 V
1,5 kV
39
kHz 3,4

dB/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 89 kg/km
60 mm
-40C
+105C
1,05 MJ/m
42,00 kg/km

Norms
Applicable standards:
UL Style:
CSA standard:

Foundation Fieldbus Spec. FF-816-1.4


CMG 105 or CL3 FT4
CSA FT 4

Application
The FOUNDATION Fieldbus is an open and neutral fieldbus standard which is primarily oriented on the requirements of process automation.
It is a functionally complete fieldbus solution for areas like temperature transmitters, pressure transmitters or valve actuators. Today we
distinguish between the specification H1 (31,25 kbit/s) and HSE (100Mbit/s). Branches like the petrochemical, chemical or the food- and
beverage industry see the advantages and use the FOUNDATION fieldbus technology.

Part no.

801193, Foundation Fieldbus FF A

Dimensions and specifications may be changed without prior notice.

R 125
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
HMCB200

fixed installed

Type
Cable structure

Fixed installation, indoor


2x2x0,22 mm

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 22/7)


Foam-skin-PE
gn, ye, pk, bu
Double core
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid, tinned
PVC
approx. 6,8 mm 0,15 mm
Green similar to RAL 6018

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:

100 Ohm 15 ohm at 1 to 100 MHz


87,6 Ohm/km
1 GOhm x km
175 Ohm/km max.
50 nF/km nom.
0,5 kV

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(db/100m)
(db)
(db)

10
8,0
47,0
39,0

16
10,0
44,0
34,0

62,5
20,0
35,0
15,0

100
27,0
32,0
5,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 71 kg/km
100 mm
-20C
+70C
0,92 MJ/m
35,00 kg/km

Norms
UL Style:

AWM Style 2502 AWM I/II A/B 80C 30V FT1

Application
These signal cables, designed specifically for use in heavy-duty industries, are the ideal solution for MOTION-CONNECT 200, 500 and 800 series
applications. They guarantee superior transmission properties and can be used under the most severe conditions. The cable cited here
conforms to HMCB200 for fixed installation.

Part no.

802471, HMCB200

Dimensions and specifications may be changed without prior notice.


* Drive Cliq is registered trademark from Siemens AG.

R 126
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
HMCB500

Drag Chain

Type
Cable structure

Drag chain applications


2x2xAWG26 + 1x2xAWG22

Inner conductor diameter 1:


Inner conductor diameter 2:
Core insulation 1:
Core insulation 2:
Core colours 1:
Core colours 2:
Stranding element 1:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 26/7)


Copper, bare (AWG 22/7)
PO
PO
gn, ye, pk, bu
rd, bk
Double core
Foil + braid
PUR
approx. 6,9 mm 0,1 mm
Green similar to RAL 6018

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:

100 Ohm 15 ohm at 1 to 100 MHz


135 Ohm/km
1 GOhm x km
270 Ohm/km max.
50 nF/km nom.
0,5 kV

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(db/100m)
(db)
(db)

10
13,0
47,0
34,0

16
16,0
44,0
28,0

62,5
32,0
35,0
3,0

100
40,0
32,0
-8,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 61 kg/km
70 mm
-20C
+60C
0,97 MJ/m
35,00 kg/km

Norms
UL Style:

AWM Style 20236 AWM I/II A/B 80C 30V FT1

Application
These signal cables, designed specifically for use in heavy-duty industries, are the ideal solution for MOTION-CONNECT 200, 500 and 800 series
applications. They guarantee superior transmission properties and can be used under the most severe conditions. The cable cited here
conforms to HMCB500 for highly-flexible applications inside motor drives.

Part no.

802472, HMCB500

Dimensions and specifications may be changed without prior notice.


* Drive Cliq is registered trademark from Siemens AG.

R 127
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
HMCB500S

Drag Chain

Type
Cable structure

Drag chain applications


2x2xAWG24 + 1x2xAWG22

Inner conductor diameter 1:


Inner conductor diameter 2:
Core insulation 1:
Core insulation 2:
Core colours 1:
Core colours 2:
Stranding element 1:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 24/7)


Copper, tinned (AWG 22/19)
Foam-skin-PE
PE
gn, ye, pk, bu
rd, bk
Double core
Foil + braid
PVC
approx. 7,0 mm 0,15 mm
Green similar to RAL 6018

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:

100 Ohm 15 ohm at 1 to 100 MHz


90 Ohm/km
1 GOhm x km
180 Ohm/km max.
50 nF/km nom.
0,5 kV

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(db/100m)
(db)
(db)

10
10,0
47,0
37,0

16
12,0
44,0
36,0

62,5
23,0
35,0
12,0

100
30,0
32,0
2,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 72 kg/km
125 mm
0C
+60C
0,00 MJ/m
38,00 kg/km

Norms
UL Style:
CSA standard:

AWM Style 2502 AWM I/II A/B 80C 30V FT1


CSA FT1

Application
These signal cables, designed specifically for use in heavy-duty industries, are the ideal solution for MOTION-CONNECT 200, 500 and 800 series
applications. They guarantee superior transmission properties and can be used under the most severe conditions. The cable cited here
conforms to HMCB500 for flexible applications inside motor drives for distances up to 100m.

Part no.

803672, HMCB500S

Dimensions and specifications may be changed without prior notice.


* Drive Cliq is registered trademark from Siemens AG.

R 128
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
HMCB800

Drag Chain

Type
Cable structure

Drag chain applications


2x2x0,15 mm + 1x2x0,38mm

Inner conductor diameter 1:


Inner conductor diameter 2:
Core insulation 1:
Core insulation 2:
Core colours 1:
Core colours 2:
Stranding element 1:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 26/19)


Copper, tinned (AWG 22/19)
PO
PO
gn, ye, pk, bu
rd, bk
Double core
Polyester foil over stranded bundle
Foil + braid
TPE
approx. 7,0 mm 0,15 mm
Green similar to RAL 6018

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:

100 Ohm 15 ohm at 1 to 100 MHz


135 Ohm/km
1 GOhm x km
270 Ohm/km max.
50 nF/km nom.
0,5 kV

Typical values
Frequency
Attenuation
Next
ACR

(MHz)
(db/100m)
(db)
(db)

10
13,0
47,0
34,0

16
16,0
44,0
28,0

62,5
32,0
35,0
3,0

100
40,0
32,0
-8,0

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 72 kg/km
105 mm
-20C
+60C
0,91 MJ/m
42,00 kg/km

Norms
UL Style:

AWM Style 20236 AWM I/II A/B 80C 30V FT1

Application
These signal cables, designed specifically for use in heavy-duty industries, are the ideal solution for MOTION-CONNECT 200, 500 and 800 series
applications. They guarantee superior transmission properties and can be used under the most severe conditions. The cable cited here
conforms to HMCB800 for highly-flexible applications.

Part no.

802473, HMCB800

Dimensions and specifications may be changed without prior notice.


* Drive Cliq is registered trademark from Siemens AG.

R 129
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
USB Bus S

Type
Cable structure

Drag chain applications


1x2xAWG28 + 1x2xAWG20

Inner conductor diameter 1:


Inner conductor diameter 2:
Core insulation 1:
Core insulation 2:
Core colours 1:
Core colours 2:
Stranding element 1:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Cu VAG + steel core (AWG 28/19)


Copper, tinned (AWG 20/37)
FEP
PO
wh, gn
rd, bk
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
Foil + braid
PUR
approx. 5,0 mm 0,2 mm
Violet similar to RAL 4001

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:

90 Ohm 15 %
232 Ohm/km
0,1 GOhm x km
464 Ohm/km max.
54 nF/km nom.
0,5 kV

Typical values
Frequency
Attenuation

(MHz)
(db/100m)

10
12,1

16
15,4

62,5
31,0

100
39,7

200
60,2

300
76,2

400
99,7

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 45 kg/km
50 mm
-20C
+60C
0,49 MJ/m
30,00 kg/km

Norms
Applicable standards:

USB-Standard 2.0

Application
These USB cables, designed specifically for use in heavy-duty industries, are the ideal solution for highly-flexible applications such as drag
chains and camera technology. They guarantee superior transmission properties. The cable cited here can be used up to a maximum cable
length of 5m.

Part no.

802469, USB S

Dimensions and specifications may be changed without prior notice.

R 130
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
USB Bus L

Type
Cable structure

Drag chain applications


1x2xAWG24 + 1x2xAWG20

Inner conductor diameter 1:


Inner conductor diameter 2:
Core insulation 1:
Core insulation 2:
Core colours 1:
Core colours 2:
Stranding element 1:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 24/19)


Copper, tinned (AWG 20/37)
PO
PO
wh, gn
rd, bk
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
Foil + braid
PUR
approx. 5,8 mm 0,2 mm
Violet similar to RAL 4001

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:

90 Ohm 15 %
140 Ohm/km
0,1 GOhm x km
280 Ohm/km max.
50 nF/km nom.
0,5 kV

Typical values
Frequency
Attenuation

(MHz)
(db/100m)

10
8,5

16
10,2

62,5
21,3

100
27,3

200
41,5

300
53,3

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 56 kg/km
75 mm
-35C
+70C
0,57 MJ/m
34,00 kg/km

Norms
Applicable standards:

USB-Standard 2.0

Application
These USB cables, designed specifically for use in heavy-duty industries, are the ideal solution for highly-flexible applications such as drag
chains and camera technology. They guarantee superior transmission properties and can be used even under the most severe conditions.
The cable cited here can be used up to a maximum cable length of 10m.

Part no.

802470, USB L

Dimensions and specifications may be changed without prior notice.

R 131
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
CAN Bus

fixed installed

Type
Cable structure

Fixed installation, indoor Fixed installation, indoor


1x2x0.22 mm (stranded) 4x1x0.22 mm (stranded)

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 24/7)


Cell PE
wh/bn
Double core
Polyester foil over stranded bundle
Cu braid, tinned
PVC
approx. 5,4 mm 0,2 mm
Violet similar to RAL 4001

Copper, bare (AWG 24/7)


Cell PE
wh, bn, gn, ye
Star quad
Polyester foil over stranded bundle
Cu braid, tinned
PVC
approx. 6,9 mm 0,2 mm
Violet similar to RAL 4001

120 Ohm 10 %
87 Ohm/km
1 GOhm x km
174 Ohm/km max.
58 nF/km nom.
30 V
1,5 kV

120 Ohm 10 %
87 Ohm/km
1 GOhm x km
174 Ohm/km max.
58 nF/km nom.
30 V
1,5 kV

approx. 41 kg/km
81 mm
-40C
+70C
0,574 MJ/m
17,00 kg/km

approx. 60 kg/km
107 mm
-40C
+70C
1,234 MJ/m
21,00 kg/km

Profibus acc. to DIN 19245 T3 and EN50170


UL Style 2571

Profibus acc. to DIN 19245 T3 and EN50170


UL Style 2571

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Nominal voltage:
Test voltage:

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

Norms
Applicable standards:
UL Style:

Application
The CAN bus series (control area network) is a variable field bus system. In the area of automation technology, complex controllers and
control units are networked. Industries, such as the textile or construction machine industry and the medical technology, use this series.
The above mentioned types are suitable for fixed laying in indoor applications. This is also a very economical solution of a BUS system.

Part no.

81286, CAN BUS

81287, CAN BUS

Dimensions and specifications may be changed without prior notice.

R 132
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
CAN Bus

fixed installed

Type
Cable structure

Fixed installation, indoor


2x2x0.22 mm (stranded)

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 24/7)


Cell PE
wh/bn, gn/ye
2 cores + 2 fillers stranded together
Polyester foil over stranded bundle
Cu braid, tinned
PVC
approx. 7,5 mm 0,3 mm
Violet similar to RAL 4001

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Nominal voltage:
Test voltage:

120 Ohm 10 %
87,6 Ohm/km
5 GOhm x km
174 Ohm/km max.
40 nF/km nom.
30 V
1,5 kV

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 60 kg/km
113 mm
-25C
+70C
1,13 MJ/m
32,00 kg/km

Norms
Applicable standards:
UL Style:
CSA standard:

Profibus acc. to DIN 19245 T3 and EN50170


UL Style 2571
CSA FT1

Application
The CAN bus series (control area network) is a variable field bus system. In the area of automation technology, complex controllers and
control units are networked. Industries, such as the textile or construction machine industry and the medical technology, use this series.
The above mentioned types are suitable for fixed laying in indoor applications. This is also a very economical solution of a BUS system.

Part no.

82509, CAN BUS

Dimensions and specifications may be changed without prior notice.

R 133
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
CAN Bus

fixed installed, 105C

Type
Cable structure

Industrial Area
2x2xAWG 24/19mm (stranded)

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 24/19)


XLPE ray cross-linking
wh/bn, gn/ye
Double core
Polyester foil over stranded bundle
Cu braid, tinned
PUR
approx. 8,4 mm 0,3 mm
Violet similar to RAL 4001

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Nominal voltage:
Test voltage:

120 Ohm 10 %
87,2 Ohm/km
1 GOhm x km
84 Ohm/km max.
42 nF/km nom.
600 V
2,5 kV

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 80 kg/km
126 mm
-40C
+105C *
40,00 kg/km

Norms
Applicable standards:
UL Style:

Profibus acc. to DIN 19245 T3 and EN50170


UL/CSA 21223 80C, 600V

Application
The CAN bus series (control area network) is a variable field bus system. In the area of automation technology, complex controllers and
control units are networked. Industries, such as the textile or construction machine industry and the medical technology, use this series.
The above mentioned types are suitable for fixed laying in indoor applications. This is also a very economical solution of a BUS system. Cable
with oil-resistant FRNC sheath and increased temperature resistance for use in the wind turbine and similar sectors. Certified to UL, the
cable can also be used in the USA and Canada.
* = with limited service life

Part no.

801982, CAN BUS

Dimensions and specifications may be changed without prior notice.

R 134
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
CAN Bus

fixed installed

Type
Cable structure

Fixed installation, indoor Fixed installation, indoor


1x2x0.34 mm (stranded) 4x1x0.34 mm (stranded)

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 22/7)


Cell PE
wh/bn
Double core
Polyester foil over stranded bundle
Cu braid, tinned
PVC
approx. 6,5 mm 0,2 mm
Violet similar to RAL 4001

Copper, bare (AWG 22/7)


Cell PE
wh/bn, gn/ye
Star quad
Polyester foil over stranded bundle
Cu braid, tinned
PVC
approx. 8,0 mm 0,2 mm
Violet similar to RAL 4001

120 Ohm 10 %
57,5 Ohm/km
5 GOhm x km
115 Ohm/km max.
40 nF/km nom.
30 V
2 kV

120 Ohm 10 %
57,5 Ohm/km
5 GOhm x km
115 Ohm/km max.
40 nF/km nom.
30 V
2 kV

approx. 54 kg/km
98 mm
-25C
+70C
1,109 MJ/m
23,00 kg/km

approx. 77 kg/km
120 mm
-25C
+70C
1,179 MJ/m
30,00 kg/km

Profibus acc. to DIN 19245 T3 and EN50170


UL Style 2571

Profibus acc. to DIN 19245 T3 and EN50170


UL Style 2571

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Nominal voltage:
Test voltage:

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

Norms
Applicable standards:
UL Style:

Application
The CAN bus series (control area network) is a variable field bus system. In the area of automation technology, complex controllers and
control units are networked. Industries, such as the textile or construction machine industry and the medical technology, use this series.
The above mentioned types are suitable for fixed laying in indoor applications. This is also a very economical solution of a BUS system.

Part no.

801572, CAN BUS

801573, CAN BUS

Dimensions and specifications may be changed without prior notice.

R 135
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
CAN Bus

fixed installed

Type
Cable structure

Fixed installation, indoor


2x2x0.34 mm (stranded)

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 22/7)


Foam-skin-PE
wh/bn, gn/ye
Double core
Polyester foil over stranded bundle
Cu braid, tinned
PVC
approx. 8,5 mm 0,2 mm
Violet similar to RAL 4001

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Nominal voltage:
Test voltage:

120 Ohm 10 %
55,4 Ohm/km
5 GOhm x km
110 Ohm/km max.
40 nF/km nom.
250 V
1,5 kV

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 85 kg/km
130 mm
-40C
+70C
1,32 MJ/m
46,00 kg/km

Norms
Applicable standards:
UL Style:
CSA standard:

Profibus acc. to DIN 19245 T3 and EN50170


CMX 75C (shielded)
CSA FT1

Application
The CAN bus series (control area network) is a variable field bus system. In the area of automation technology, complex controllers and
control units are networked. Industries, such as the textile or construction machine industry and the medical technology, use this series.
The above mentioned types are suitable for fixed laying in indoor applications. This is also a very economical solution of a BUS system.

Part no.

803344, CAN BUS

Dimensions and specifications may be changed without prior notice.

R 136
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
CAN Bus

fixed installed

Type
Cable structure

Fixed installation, indoor Fixed installation, indoor


1x2x0.50 mm (stranded) 4x1x0.50 mm (stranded)

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 20/7)


Foam-skin-PE
wh/bn
Double core
Polyester foil over stranded bundle
Cu braid, tinned
PVC
approx. 7,0 mm 0,2 mm
Violet similar to RAL 4001

Copper, bare (AWG 20/7)


Foam-skin-PE
wh, bn, gn, ye
Star quad
Polyester foil over stranded bundle
Cu braid, tinned
PVC
approx. 8,5 mm 0,2 mm
Violet similar to RAL 4001

120 Ohm 10 %
37 Ohm/km
1 GOhm x km
74 Ohm/km max.
50 nF/km nom.
1,5 kV

120 Ohm 10 %
37 Ohm/km
1 GOhm x km
74 Ohm/km max.
65 nF/km nom.
1,5 kV

approx. 69 kg/km
105 mm
-40C
+70C
1,09 MJ/m
30,00 kg/km

approx. 100 kg/km


128 mm
-40C
+70C
1,64 MJ/m
45,00 kg/km

Profibus acc. to DIN 19245 T3 and EN50170


UL Style 2571

Profibus acc. to DIN 19245 T3 and EN50170


UL Style 2571

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

Norms
Applicable standards:
UL Style:

Application
The CAN bus series (control area network) is a variable field bus system. In the area of automation technology, complex controllers and
control units are networked. Industries, such as the textile or construction machine industry and the medical technology, use this series.
The above mentioned types are suitable for fixed laying in indoor applications. This is also a very economical solution of a BUS system.

Part no.

800571, CAN BUS

800685, CAN BUS

Dimensions and specifications may be changed without prior notice.

R 137
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
CAN Bus

fixed installed

Type
Cable structure

Fixed installation, indoor


2x2x0.50 mm (stranded)

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 20/7)


Foam-skin-PE
wh/bn, gn/ye
Double core
Polyester foil over stranded bundle
Cu braid, tinned
PVC
approx. 9,5 mm 0,2 mm
Violet similar to RAL 4001

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Nominal voltage:
Test voltage:

120 Ohm 10 %
34,4 Ohm/km
5 GOhm x km
68 Ohm/km max.
40 nF/km nom.
250 V
1,5 kV

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 116 kg/km


150 mm
-40C
+70C
1,62 MJ/m
60,00 kg/km

Norms
Applicable standards:
UL Style:
CSA standard:

Profibus acc. to DIN 19245 T3 and EN50170


CMX 75C (shielded)
CSA FT1

Application
The CAN bus series (control area network) is a variable field bus system. In the area of automation technology, complex controllers and
control units are networked. Industries, such as the textile or construction machine industry and the medical technology, use this series.
The above mentioned types are suitable for fixed laying in indoor applications. This is also a very economical solution of a BUS system.

Part no.

803722, CAN BUS

Dimensions and specifications may be changed without prior notice.

R 138
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
CAN Bus

fixed installed

Type
Cable structure

Fixed installation, indoor Fixed installation, indoor


1x2x0.75 mm (stranded) 4x1x0.75 mm (stranded)

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 18/19)


Foam-skin-PE
wh/bn
Double core
Polyester foil over stranded bundle
Cu braid, tinned
PVC
approx. 8,7 mm 0,3 mm
Violet similar to RAL 4001

Copper, bare (AWG 18/19)


Foam-skin-PE
wh/bn, gn/ye
Star quad
Polyester foil over stranded bundle
Cu braid, tinned
PVC
approx. 8,8 mm 0,3 mm
Violet similar to RAL 4001

120 Ohm 15 %
27,5 Ohm/km
1 GOhm x km
55 Ohm/km max.
42 nF/km nom.
300 V
1,5 kV

120 Ohm 15 %
27,5 Ohm/km
1 GOhm x km
55 Ohm/km max.
42 nF/km nom.
300 V
1,5 kV

approx. 101 kg/km


110 mm
-40C
+70C
1,67 MJ/m
40,00 kg/km

approx. 112 kg/km


120 mm
-40C
+70C
1,76 MJ/m
58,00 kg/km

Profibus acc. to DIN 19245 T3 and EN50170


UL Style 2571
CSA FT1

Profibus acc. to DIN 19245 T3 and EN50170


UL Style 2571
CSA FT1

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Nominal voltage:
Test voltage:

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

Norms
Applicable standards:
UL Style:
CSA standard:

Application
The CAN bus series (control area network) is a variable field bus system. In the area of automation technology, complex controllers and
control units are networked. Industries, such as the textile or construction machine industry and the medical technology, use this series.
The above mentioned types are suitable for fixed laying in indoor applications. This is also a very economical solution of a BUS system.

Part no.

803383, CAN BUS

803384, CAN BUS

Dimensions and specifications may be changed without prior notice.

R 139
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
CAN Bus

Drag Chain

Type
Cable structure

Drag chain applications


Drag chain applications
1x2x0.25 mm (stranded) 4x1x0.25 mm (stranded)

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 24/19)


PE
wh/bn
Double core
Polyester foil over stranded bundle
Cu braid, tinned
PUR
approx. 6,2 mm 0,3 mm
Violet similar to RAL 4001

Copper, bare (AWG 24/19)


PE
wh, bn, gn, ye
Star quad
Polyester foil over stranded bundle
Cu braid, tinned
PUR
approx. 6,5 mm 0,3 mm
Violet similar to RAL 4001

120 Ohm 10 %
85 Ohm/km
1 GOhm x km
170 Ohm/km max.
50 nF/km nom.
1,5 kV

120 Ohm 10 %
85 Ohm/km
1 GOhm x km
170 Ohm/km max.
50 nF/km nom.
1,5 kV

approx. 40 kg/km
90 mm
-20C
+70C
0,798 MJ/m
18,00 kg/km

approx. 45 kg/km
95 mm
-20C
+70C
0,943 MJ/m
25,00 kg/km

Profibus acc. to DIN 19245 T3 and EN50170

Profibus acc. to DIN 19245 T3 and EN50170

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

Norms
Applicable standards:

Application
The CAN bus series (control area network) is a variable field bus system. In the area of automation technology, complex controllers and
control units are networked. Industries, such as the textile or construction machine industry and the medical technology, use this series.
The lines specified here are designed for highly flexible applications. This is also a very economical solution of a BUS system.

Part no.

81911, CAN BUS, highly flexible

81912, CAN BUS, highly flexible

Dimensions and specifications may be changed without prior notice.

R 140
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Bus Cables
CAN Bus

Drag Chain, UL

Type
Cable structure

Drag chain applications


Drag chain applications
1x2x0.34 mm (stranded) 4x1x0.34 mm (stranded)

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 22/43)


Foam-skin-PE
wh/bn
2 cores + 2 fillers stranded together
Cu braid, tinned
PUR
approx. 6,9 mm 0,3 mm
Violet similar to RAL 4001

Copper, bare (AWG 22/43)


Foam-skin-PE
wh/bn, gn/ye
Star quad
Cu braid, tinned
PUR
approx. 7,5 mm 0,3 mm
Violet similar to RAL 4001

120 Ohm 15 %
56 Ohm/km
5 GOhm x km
170 Ohm/km max.
40 nF/km nom.
250 V
1,5 kV

120 Ohm 15 %
56 Ohm/km
5 GOhm x km
170 Ohm/km max.
40 nF/km nom.
250 V
1,5 kV

approx. 54 kg/km
70 mm
-30C
+70C
1,20 MJ/m
30,00 kg/km

approx. 64 kg/km
75 mm
-30C
+70C
1,20 MJ/m
42,00 kg/km

Profibus acc. to DIN 19245 T3 and EN50170


CMX 444

Profibus acc. to DIN 19245 T3 and EN50170


CMX 444

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Nominal voltage:
Test voltage:

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

Norms
Applicable standards:
UL Style:

Application
The CAN bus series (control area network) is a variable field bus system. In the area of automation technology, complex controllers and
control units are networked. Industries, such as the textile or construction machine industry and the medical technology, use this series.
The lines specified here are designed for highly flexible applications where also a UL Certificate is required.

Part no.

802182, CAN BUS, highly flexible

802339, CAN BUS, highly flexible

Dimensions and specifications may be changed without prior notice.

R 141
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
I-BUS

fixed installed

Type
Cable structure

Fixed installation, indoor


3x2x0.22 mm

Fixed installation, indoor


3x2x0.22 mm +
3x1.0 mm

Inner conductor diameter:


Inner conductor diameter 2:
Core insulation:
Core insulation 2:
Core colours:
Core colours 2:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 24/7)


PE
wh/bn, gn/rd, ye/gn
Double core
Polyester foil over stranded bundle
Cu braid, bare
PVC
approx. 7,0 mm 0,3 mm
Pastel turquoise similar to RAL 6034

Copper, bare (AWG 24/7)


Copper, bare (AWG 17/56)
PE
PE
wh/bn, gn/rd, ye/gn
bu, rd, gnye
Double core
Polyester foil over stranded bundle
Cu braid, bare
PVC
approx. 8,0 mm 0,3 mm
Pastel turquoise similar to RAL 6034

100 Ohm 15 Ohm


96 Ohm/km
1 GOhm x km
192 Ohm/km max.
60 nF/km nom.
1 kV
256 kHz < 1,5
772 kHz < 2,4
1
MHz < 2,7
4
MHz < 5,2
10
MHz < 8,4
16
MHz < 11,2
20
MHz < 11,9

100 Ohm 15 Ohm


96 Ohm/km
1 GOhm x km
192 Ohm/km max.
60 nF/km nom.
1 kV
256 kHz < 3,0
772 kHz < 4,8
1
MHz < 5,2
4
MHz < 10,4
10
MHz < 16,8
16
MHz < 22,4
20
MHz < 23,8

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:
Attenuation:

dB/100m
dB/100m
dB/100m
dB/100m
dB/100m
dB/100m
dB/100m

dB/100m
dB/100m
dB/100m
dB/100m
dB/100m
dB/100m
dB/100m

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 70 kg/km
110 mm
-40C
+70C
1,20 MJ/m
35,00 kg/km

approx. 96 kg/km
120 mm
-40C
+70C
1,31 MJ/m
68,00 kg/km

interbus specification 2.0, IEC61158


UL Style 2571

interbus specification 2.0, IEC61158


UL Style 2571

Norms
Applicable standards:
UL Style:

Application
Interbus-S is an inexpensive way to network sensors and actuators with all standard automation instruments. The twisted two-core conductor
is used as a standard transfer medium. This bus system replaces the expensive parallel cabling for the different signal types in the lower
levels of automation technique and combines the cables in a single bus cable. Interbus components are connected with this long-distance
BUS cable.

Part no.

80778, I-BUS

81202, I-BUS

Dimensions and specifications may be changed without prior notice.

R 142
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
I-BUS

fixed installed, halogenfree

Type
Cable structure

Fixed installation, indoor


3x2x0.22 mm

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 24/7)


PE
wh/bn, gn/rd, ye/gn
Double core
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid, bare
PE
approx. 7,0 mm 0,3 mm
Pastel turquoise similar to RAL 6034

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:
Attenuation:

100 Ohm 15 Ohm


96 Ohm/km
1 GOhm x km
192 Ohm/km max.
50 nF/km nom.
1 kV
256 kHz < 1,5
772 kHz < 2,4
1
MHz < 2,7
4
MHz < 5,2
10
MHz < 8,4
16
MHz < 11,2
20
MHz < 11,9

dB/100m
dB/100m
dB/100m
dB/100m
dB/100m
dB/100m
dB/100m

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 67 kg/km
110 mm
-25C
+60C
1,10 MJ/m
35,00 kg/km

Norms
Applicable standards:

interbus specification 2.0, IEC61158

Application
Interbus-S is an inexpensive way to network sensors and actuators with all standard automation instruments. The twisted two-core conductor
is used as a standard transfer medium. This bus system replaces the expensive parallel cabling for the different signal types in the lower
levels of automation technique and combines the cables in a single bus cable. Interbus components are connected with this long-distance
BUS cable. The cable with halogenfree jacket is used for outdoor applications and in the food-industry.

Part no.

81557, I-BUS

Dimensions and specifications may be changed without prior notice.

R 143
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
I-BUS

Drag Chain

Type
Cable structure

Drag chain applications


3x2x0.25 mm

Drag chain applications


3x2x0.25 mm +
3x1.0 mm

Inner conductor diameter:


Inner conductor diameter 2:
Core insulation:
Core insulation 2:
Core colours:
Core colours 2:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 24/19)


PE
wh/bn, gn/rd, ye/gn
Double core
Polyester foil over stranded bundle
Cu braid, bare
PUR
approx. 7,6 mm 0,3 mm
Pastel turquoise similar to RAL 6034

Copper, bare (AWG 24/19)


Copper, bare (AWG 17/65)
PE
PE
wh/bn, gn/rd, ye/gn
bu, rd, gnye
Double core
Polyester foil over stranded bundle
Cu braid, tinned
PUR
approx. 8,6 mm 0,3 mm
Violet similar to RAL 4001

100 Ohm 15 Ohm


96 Ohm/km
1 GOhm x km
192 Ohm/km max.
60 nF/km nom.
1 kV
256 kHz < 1,5
772 kHz < 2,4
1
MHz < 2,7
4
MHz < 5,2
10
MHz < 8,4
16
MHz < 11,2
20
MHz < 11,9

100 Ohm 15 Ohm


96 Ohm/km
1 GOhm x km
192 Ohm/km max.
60 nF/km nom.
1 kV
256 kHz < 3,0
772 kHz < 4,8
1
MHz < 5,2
4
MHz < 10,4
10
MHz < 16,8
16
MHz < 22,4
20
MHz < 23,8

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:
Attenuation:

dB/100m
dB/100m
dB/100m
dB/100m
dB/100m
dB/100m
dB/100m

dB/100m
dB/100m
dB/100m
dB/100m
dB/100m
dB/100m
dB/100m

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 63 kg/km
90 mm
-20C
+70C
0,937 MJ/m
36,00 kg/km

approx. 92 kg/km
100 mm
-20C
+70C
1,227 MJ/m
70,00 kg/km

interbus specification 2.0, IEC61158

interbus specification 2.0, IEC61158

Norms
Applicable standards:

Application
Interbus-S is an inexpensive way to network sensors and actuators with all standard automation instruments. The twisted two-core conductor
is used as a standard transfer medium. This bus system replaces the expensive parallel cabling for the different signal types in the lower
levels of automation technique and combines the cables in a single bus cable. Interbus components are connected with this long-distance
BUS cable. The above mentioned types are suitable for drag chain application.

Part no.

81203, I-BUS

82696, I-BUS

Dimensions and specifications may be changed without prior notice.

R 144
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS-Cables
Multibus I, high exible

Type
Cable structure

Multibus I, 15 cores high exible

Probus:
DeviceNetTM:
Interbus:
Power cores:
Protective earth core:
Stranding:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

1 x 2 x AWG 22 mm2 (Foam-Skin PO/rd/gn)


2 x 2 x AWG 22 mm2 (Foam-Skin PO/wh/bn, ye/gn)
2 x 2 x 0,25 (Foam-Skin PO/ gn/pk, ye/gn)
4 x 1 x 1,0 mm2 (PO/rd, bl, bu, bn)
1,0 mm2 (PO/gnye)
Single cores totaly stranded together and lled with plastic elements
PP vlies
PUR, halogenfree
app. 14,7 mm
violet similar to RAL 4001

Electrical data
Characteristic impedance:

Conductor resistance:

Insulation resistance:
Mutual capacitance:

Testvoltage:

150 + -15 Ohm (Probus)


120 + -12 Ohm (DeviceNetTM)
100 + -15 Ohm (Interbus)
<= 20 Ohm/km (power cores + protection core)
<= 70 Ohm/km (Probus)
<= 70 Ohm/km (DeviceNetTM)
<= 80 Ohm/km (Interbus)
>= 500 Mohm x km (at 20 C)
30 pF/m nominal (Probus)
40 pF/m nominal (DeviceNetTM)
50 pF/m nominal (Interbus)
2500 V (core/ core)
1500 V (core/ screen)

Mechanical data
Bending radius single:
Bending radius repeated:
Tensile strength static:
Tensile strength dynamic:
Oil resistance:
Flame resistance:
FCKW free:
Self extinguishable:
Other attributes:

<= 70 mm
<= 110 mm
300 N
140 N
Diesel, Biodiesel, ASTM-l 1, ASTM-l 2, Vitam EHF, Biohydran
HD 405.1, IEC 60332-1, VW1/ FT1 acc. C-UL
yes
yes
PVC free, free of lacquer wetting disturbing substances, siliconfree,
resistant against PVC exibiliser and cable fat RB1

Thermal attributes
Operating temperature range:
Laying temperature range:

- 40 C to + 80 C
- 30 C to + 80 C

Norms

Probus standard, DeviceNetTM standard, Interbus standard

UL-Style

VW1/ FT1 acc. C-UL

Application

Drag chains, torsion applications (according HELU specikation)

Part no.

801652, Multibus I, 15 cores

R 145
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS-Cables
Multibus II, high exible

Type
Cable structure

Multibus II, 15 cores high exible

Probus:
DeviceNetTM:
Power cores 1:
Power cores 2:
Protective earth core:
Stranding:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

1 x 2 x 0,34 mm2 (Foam-Skin PO/rd/gn)


4 x 2 x 0,34 mm2 (Foam-Skin PE/ye, or, wh, bu-ye, or, wh, bu)
2 x 1,0 mm2 (PO/rd, bl)
2 x 1,5 mm2 (PO/bu, bn)
1,5 mm2 (PO/gnye)
Single cores totaly stranded together and lled with plastic elements
PP vlies
PUR, halogenfree
app. 15,0 mm
violet similar to RAL 4001

Electrical data
Characteristic impedance:
Conductor resistance:

Insulation resistance:
Mutual capacitance:
Testvoltage:

150 + -15 Ohm (Probus)


100 + -15 Ohm (PROFInet)
<= 20 Ohm/km (power cores + protection core)
<= 70 Ohm/km (Probus)
<= 62 Ohm/km (PROFInet)
>= 500 Mohm x km (at 20 C)
30 pF/m nominal (Probus)
40 pF/m nominal (PROFInet)
2500 V (core/ core)
1500 V (core/ screen)

Mechanical data
Bending radius single:
Bending radius repeated:
Tensile strength static:
Tensile strength dynamic:
Oil resistance:
Flame resistance:
FCKW free:
Self extinguishable:
Other attributes:

<= 70 mm
<= 110 mm
300 N
140 N
Diesel, Biodiesel, ASTM-l 1, ASTM-l 2, Vitam EHF, Biohydran
HD 405.1, IEC 60332-1, VW1/ FT1 acc. C-UL
yes
yes
PVC free, free of lacquer wetting disturbing substances, siliconfree,
resistant against PVC exibiliser and cable fat RB1

Thermal attributes
Operating temperature range:
Laying temperature range:

- 40 C to + 80 C
- 20 C to + 80 C

Norms
UL-Style
Application
Part no.

Probus standard, PROFInet standard


VW1/ FT1 acc. C-UL
Drag chains, torsion applications (according HELU specication)
804115, Multibus II, 15 cores

R 146
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
A-BUS

EPDM

Type
Cable structure

Actuator Sensor Interface Actuator Sensor Interface


2x1.5 mm
2x1.5 mm

Inner conductor:
Core insulation:
Core colours:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Outer sheath colour:

Copper, tinned
Rubber compound
bu, bn
EPDM
Yellow similar to RAL 1023

Copper, tinned
Rubber compound
bu, bn
EPDM
Black similar to RAL 9005

13,7 Ohm/km
1 GOhm x km
27 Ohm/km max.
32 V
1 kV at 15 min.

13,7 Ohm/km
1 GOhm x km
27 Ohm/km max.
48 V
1 kV at 15 min.

approx. 70 kg/km
30 mm
-40C
+85C
0,975 MJ/m
31,00 kg/km

approx. 70 kg/km
30 mm
-40C
+85C
0,975 MJ/m
31,00 kg/km

ASI standard

ASI standard

Electrical data
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Nominal voltage:
Test voltage:

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

Norms
Applicable standards:

Application
AS components are interconnected with this special system cable. With the AS interface, the cable assembly from the control system to the
sensor/actuator is not needed. The AS interface is the field bus system that transmitts both data and power in one single cable. With fast
contacting in penetration technique, the possibility of errors in cabling is largely reduced. The special outer jacket provides protection against
bio-oil, grease, and refrigerant lubricants, and the cable is therefore even suitable for applications in wet surroundings, in machinery and
plant construction, as well as in the machine tool and automotive industry.

Part no.

80824, A-BUS EPDM

80825, A-BUS EPDM

Dimensions and specifications may be changed without prior notice.

R 147
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
A-BUS

PUR, UL/CSA

Type
Cable structure

Actuator Sensor Interface Actuator Sensor Interface


2x1.5 mm
2x1.5 mm

Inner conductor:
Core insulation:
Core colours:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Outer sheath colour:

Copper, tinned
PO
bu, bn
PUR
Yellow similar to RAL 1023

Copper, tinned
PO
bu, bn
PUR
Black similar to RAL 9005

13,7 Ohm/km
1 GOhm x km
27 Ohm/km max.
32 V
1 kV at 15 min.

13,7 Ohm/km
1 GOhm x km
27 Ohm/km max.
48 V
1 kV at 15 min.

approx. 64 kg/km
30 mm
-40C
+80C
0,965 MJ/m
31,00 kg/km

approx. 64 kg/km
30 mm
-40C
+80C
0,965 MJ/m
31,00 kg/km

ASI standard
AWM Style 20549/10493
CSA FT2

ASI standard
AWM Style 20549/10493
CSA FT2

Electrical data
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Nominal voltage:
Test voltage:

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

Norms
Applicable standards:
UL Style:
CSA standard:

Application
AS components are interconnected with this special system cable. With the AS interface, the cable assembly from the control system to the
sensor/actuator is not needed. The AS interface is the field bus system that transmitts both data and power in one single cable. With fast
contacting in penetration technique, the possibility of errors in cabling is largely reduced. The special outer jacket provides protection against
oil, grease, and refrigerant lubricants, and the cable is therefore even suitable for applications in wet surroundings, in machinery and plant
construction, as well as in the machine tool and automotive industry. The PUR variant is suitable for heavy-duty industrial environments.
These types are certified for the American market (UL 1581, FT2) through the use of special materials.

Part no.

82434, A-BUS PUR

82822, A-BUS PUR

Dimensions and specifications may be changed without prior notice.

R 148
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
A-BUS

TPE

Type
Cable structure

Actuator Sensor Interface Mobile use


2x1.5 mm
2x1.5 mm

Inner conductor:
Core insulation:
Core colours:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Outer sheath colour:

Copper, tinned
TPE
bu, bn
TPE
Yellow

Copper, tinned
TPE
bu, bn
TPE
Black

13,7 Ohm/km
1 GOhm x km
27 Ohm/km max.
32 V
1,5 kV at 15 min.

13,7 Ohm/km
1 GOhm x km
27 Ohm/km max.
32 V
1,5 kV at 15 min.

approx. 70 kg/km
24 mm
-40C
+105C
1,10 MJ/m
31,00 kg/km

approx. 70 kg/km
24 mm
-40C
+105C
1,10 MJ/m
31,00 kg/km

ASI standard

ASI standard

Electrical data
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Nominal voltage:
Test voltage:

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

Norms
Applicable standards:

Application
AS components are interconnected with this special system cable. With the AS interface, the cable assembly from the control system to the
sensor/actuator is not needed. The AS interface is the field bus system that transmitts both data and power in one single cable. With fast
contacting in penetration technique, the possibility of errors in cabling is largely reduced. The special outer jacket provides protection against
many oils, grease, and refrigerant lubricants, and the cable is therefore even suitable for applications in wet surroundings, in machinery and
plant construction, as well as in the machine tool and automotive industry.

Part no.

801846, A-BUS TPE

801847, A-BUS TPE

Dimensions and specifications may be changed without prior notice.

R 149
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
A-BUS

TPE, UL/CSA

Type
Cable structure

Actuator Sensor Interface Mobile use


2x1.5 mm
2x1.5 mm

Inner conductor:
Core insulation:
Core colours:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Outer sheath colour:

Copper, tinned
TPE
bu, bn
TPE
Yellow

Copper, tinned
TPE
bu, bn
TPE
Black

13,7 Ohm/km
1 GOhm x km
27 Ohm/km max.
32 V
1,5 kV at 15 min.

13,7 Ohm/km
1 GOhm x km
27 Ohm/km max.
48 V
1,5 kV at 15 min.

approx. 70 kg/km
24 mm
-40C
+105C
1,10 MJ/m
31,00 kg/km

approx. 70 kg/km
24 mm
-40C
+105C
1,10 MJ/m
31,00 kg/km

ASI standard
21439 nach UL 758
CSA FT2

ASI standard
21439 nach UL 758
CSA FT2

Electrical data
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Nominal voltage:
Test voltage:

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

Norms
Applicable standards:
UL Style:
CSA standard:

Application
AS components are interconnected with this special system cable. With the AS interface, the cable assembly from the control system to the
sensor/actuator is not needed. The AS interface is the field bus system that transmitts both data and power in one single cable. With fast
contacting in penetration technique, the possibility of errors in cabling is largely reduced. The special outer jacket provides protection against
many oils, grease, and refrigerant lubricants, and the cable is therefore even suitable for applications in wet surroundings, in machinery and
plant construction, as well as in the machine tool and automotive industry. These variations are certified for the American market (UL 1581,
FT2) through the use of special materials.

Part no.

801954, A-BUS UL

801955, A-BUS UL

Dimensions and specifications may be changed without prior notice.

R 150
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
AS-Interface

Electrical Cabinet FLIH

Type
Cable structure

Fixed installation, indoor


2x0,86/ 2,5

Inner conductor:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Outer sheath colour:

Copper, tinned
FRNC
Yellow

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Nominal voltage:
Test voltage:

105 Ohm 35 Ohm


23 Ohm/km
0,01 GOhm x km
46 Ohm/km max.
300 V
2 kV at 15 min.

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 24 kg/km
15 mm
-25C
+70C
0,30 MJ/m
20,00 kg/km

Norms
Applicable standards:
UL Style:

ASI standard
UL-Style 2440 (80C/300V)

Application
AS components are interconnected with this special system cable. With the AS interface, the cable assembly from the control system to the
sensor/actuator is not needed. The AS interface is the field bus system that transmitts both data and power in one single cable. With fast
contacting in penetration technique, the possibility of errors in cabling is largely reduced. This type is especially constructed for cabling
inside electrical cabinets.

Part no.

802183, AS-Interface FLIH

Dimensions and specifications may be changed without prior notice.

R 151
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
SENSOR-AKTOR

TPM

Type
Cable structure

Sensor Actuator Cable


4x0.34 mm

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 22/43)


PP
wh, bu, bk, bn
Star quad
PETP fleece
TPM
approx. 4,7 mm 0,2 mm
Black

Electrical data
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Test voltage:

60 Ohm/km
1 GOhm x km
120 Ohm/km max.
1,5 kV

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 29 kg/km
75 mm
-25C
+60C
0,505 MJ/m
15,00 kg/km

Norms
UL Style:

AWM Style 21198/ 1049

Application
All Sensors and actuators (such as proximity switches, magnet valves) in a field are installed with these special cables, whereby particular
attention is paid to the corrosive environmental conditions. Due to the decentralisation of control and electro-technical function groups,
connected directly to the components in the field, significant savings potentials are realized. The main applications of these cables are in
machine construction.

Part no.

81712, sensor actuator

Dimensions and specifications may be changed without prior notice.

R 152
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
DeviceNet

PVC

Type
Cable structure

Fixed installation, indoor


1x2xAWG18 +
1x2xAWG15

Fixed installation, indoor


1x2xAWG24 +
1x2xAWG22

Inner conductor diameter 1:


Inner conductor diameter 2:
Core insulation 1:
Core insulation 2:
Core colours 1:
Core colours 2:
Stranding element 1:
Shielding 1:
Shielding 2:
Total shielding:
Drain wire:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, tinned (AWG 18/19)


Copper, tinned (AWG 15/19)
Foam-skin-PE
PVC
light bu, wh
rd, bk
Double core
Polyester foil, aluminium-lined
Cu braid, tinned
yes
PVC
approx. 12,2 mm 0,3 mm
Grey

Copper, tinned (AWG 24/19)


Copper, tinned (AWG 22/19)
Foam-skin-PE
PVC
light bu, wh
rd, bk
Double core
Polyester foil, aluminium-lined
Copper shifting, tinned
yes
PVC
approx. 6,9 mm 0,3 mm
Grey

120 Ohm 10 %
22,6 Ohm/km
0,2 GOhm x km
45 Ohm/km max.
39,8 nF/km nom.
2 kV
125 kHz < 0,42
500 kHz < 0,81

120 Ohm 10 %
90 Ohm/km
0,2 GOhm x km
180 Ohm/km max.
39,8 nF/km nom.
2 kV
125 kHz < 0.95
500 kHz < 1.64

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:
Attenuation:

dB/100m
dB/100m

dB/100m
dB/100m

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 192 kg/km


190 mm
-20C
+80C
2,92 MJ/m
85,00 kg/km

approx. 67 kg/km
110 mm
-20C
+80C
0,91 MJ/m
35,00 kg/km

ODVA DeviceNet
CMG 75C PLTC FT4
CEC: CMG FT4

ODVA DeviceNet
CMG 75C PLTC FT4
CSA FT 4

Norms
Applicable standards:
UL Style:
CSA standard:

Application
DeviceNet is a bus system developed by Allen Bradley (Rockwell Automation). These cables are used to interconnect various industrial
devices, such as SPS controls or limit switches. The special characteristic of this bus system is that a data pair and a power supply pair are
integrated in one cable. These cables with PVC sheath are designed for fixed installation.

Part no.

800683, DeviceNet PVC

800684, DeviceNet PVC

Dimensions and specifications may be changed without prior notice.

R 153
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
DeviceNet

FRNC

Type
Cable structure

Fixed installation, indoor


1x2xAWG18 +
1x2xAWG15

Fixed installation, indoor


1x2xAWG24 +
1x2xAWG22

Inner conductor diameter 1:


Inner conductor diameter 2:
Core insulation 1:
Core insulation 2:
Core colours 1:
Core colours 2:
Stranding element 1:
Shielding 1:
Shielding 2:
Total shielding:
Drain wire:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, tinned (AWG 18/19)


Copper, tinned (AWG 15/19)
Cell PE
Cell PE
light bu, wh
rd, bk
Double core
Polyester foil, aluminium-lined
Cu braid, tinned
yes
FRNC
approx. 12,2 mm 0,3 mm
Violet similar to RAL 4001

Copper, tinned (AWG 24/19)


Copper, tinned (AWG 22/19)
Cell PE
Cell PE
light bu, wh
rd, bk
Double core
Polyester foil, aluminium-lined
Cu braid, tinned
yes
FRNC
approx. 6,9 mm 0,3 mm
Violet similar to RAL 4001

120 Ohm 10 %
22,6 Ohm/km
0,2 GOhm x km
45 Ohm/km max.
39 nF/km nom.
2 kV
125 kHz < 0.42
500 kHz < 0.81

120 Ohm 10 %
90 Ohm/km
0,2 GOhm x km
180 Ohm/km max.
39,8 nF/km nom.
2 kV
125 kHz < 0.95
500 kHz < 1.64

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:
Attenuation:

dB/100m
dB/100m

dB/100m
dB/100m

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 195 kg/km


190 mm
-25C
+80C
2,73 MJ/m
85,00 kg/km

approx. 70 kg/km
110 mm
-25C
+80C
0,82 MJ/m
34,00 kg/km

ODVA DeviceNet
CL2 CMG
CEC: CMG FT4

ODVA DeviceNet
CL2 CMG
CEC: CMG FT4

Norms
Applicable standards:
UL Style:
CSA standard:

Application
DeviceNet is a bus system developed by Allen Bradley (Rockwell Automation). These cables are used to interconnect various industrial
devices, such as SPS controls or limit switches. The special characteristic of this bus system is that a data pair and a power supply pair are
integrated in one cable. These cables with FRNC sheath are designed for fixed installation.

Part no.

800681, DeviceNet FRNC

800682, DeviceNet FRNC

Dimensions and specifications may be changed without prior notice.

R 154
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
DeviceNet

CPE

Type
Cable structure

Fixed installation, indoor


1x2xAWG18 +
1x2xAWG15

Fixed installation, indoor


1x2xAWG24 +
1x2xAWG22

Inner conductor diameter 1:


Inner conductor diameter 2:
Core insulation 1:
Core insulation 2:
Core colours 1:
Core colours 2:
Stranding element 1:
Shielding 1:
Shielding 2:
Total shielding:
Drain wire:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, tinned (AWG 18/19)


Copper, tinned (AWG 15/19)
PE
PE
light bu, wh
rd, bk
Double core
Polyester foil, aluminium-lined
Cu braid, tinned
yes
CPE
approx. 12,0 mm 0,3 mm
Yellow

Copper, tinned (AWG 24/19)


Copper, tinned (AWG 22/19)
PE
PVC
light bu, wh
rd, bk
Double core
Polyester foil, aluminium-lined
Cu braid, tinned
yes
CPE
approx. 7,0 mm 0,3 mm
Yellow

120 Ohm 10 %
22,6 Ohm/km
0,2 GOhm x km
45 Ohm/km max.
39 nF/km nom.
2 kV
125 kHz < 0,43
500 kHz < 0,82

120 Ohm 10 %
90 Ohm/km
0,2 GOhm x km
180 Ohm/km max.
39 nF/km nom.
2 kV
125 kHz < 0,95
500 kHz < 1,64

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:
Attenuation:

dB/100m
dB/100m

dB/100m
dB/100m

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 195 kg/km


190 mm
-20C
+60C
2,73 MJ/m
71,20 kg/km

approx. 70 kg/km
110 mm
-20C
+60C
0,82 MJ/m
28,10 kg/km

ODVA DeviceNet
CMG PLTC
CEC: CMG FT4

ODVA DeviceNet
CL2 CMG
CEC: CMG FT4

Norms
Applicable standards:
UL Style:
CSA standard:

Application
DeviceNet is a bus system developed by Allen Bradley (Rockwell Automation). These cables are used to interconnect various industrial
devices, such as SPS controls or limit switches. The special characteristic of this bus system is that a data pair and a power supply pair are
integrated in one cable. These cables are designed for fixed installation.

Part no.

81907, DeviceNet CPE

81908, DeviceNet CPE

Dimensions and specifications may be changed without prior notice.

R 155
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
DeviceNet

PUR, flexible

Type
Cable structure

Drag chain applications


1x2xAWG18 +
1x2xAWG15

Drag chain applications


1x2xAWG24 +
1x2xAWG22

Inner conductor diameter 1:


Inner conductor diameter 2:
Core insulation 1:
Core insulation 2:
Core colours 1:
Core colours 2:
Stranding element 1:
Shielding 1:
Shielding 2:
Total shielding:
Drain wire:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, tinned (AWG 18/40)


Copper, tinned (AWG 15/84)
Cell PE
Cell PE
light bu, wh
rd, bk
Double core
Polyester foil, aluminium-lined
Cu braid, tinned
yes
PUR
approx. 12,0 mm 0,3 mm
Violet similar to RAL 4001

Copper, tinned (AWG 24/19)


Copper, tinned (AWG 22/19)
Cell PE
Cell PE
light bu, wh
rd, bk
Double core
Polyester foil, aluminium-lined
Cu braid, tinned
yes
PUR
approx. 7,0 mm 0,3 mm
Violet similar to RAL 4001

120 Ohm 10 %
22,6 Ohm/km
0,2 GOhm x km
45 Ohm/km max.
39,8 nF/km nom.
2 kV
125 kHz < 0,41
500 kHz < 0,82

120 Ohm 10 %
90 Ohm/km
0,2 GOhm x km
45 Ohm/km max.
39,8 nF/km nom.
2 kV
125 kHz < 0,95
500 kHz < 1,64

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:
Attenuation:

dB/100m
dB/100m

dB/100m
dB/100m

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 185 kg/km


61 mm
-40C
+80C
2,54 MJ/m
90,00 kg/km

approx. 68 kg/km
35 mm
-40C
+80C
0,76 MJ/m
35,00 kg/km

ODVA DeviceNet
CMX 75C CL2X

ODVA DeviceNet
CMX 75C CL2X

Norms
Applicable standards:
UL Style:

Application
DeviceNet is a bus system developed by Allen Bradley (Rockwell Automation). These cables are used to interconnect various industrial
devices, such as SPS controls or limit switches. The special characteristic of this bus system is that a data pair and a power supply pair are
integrated in one cable. These cables with PUR sheath are designed for highly flexible applications.

Part no.

81909, DeviceNet PUR

81910, DeviceNet PUR

Dimensions and specifications may be changed without prior notice.

R 156
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
CC-Link BUS

PVC

Type
Cable structure

Fixed installation, indoor


3x0.5 mm

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Drain wire:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 20/7)


Cell PE
wh, bu, ye
Triple core
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
Cu braid, tinned
yes
PVC
approx. 7,7 mm 0,3 mm
Red

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:
Attenuation:

110 Ohm 15 Ohm


37,8 Ohm/km
10 GOhm x km
75 Ohm/km max.
60 nF/km nom.
2 kV
1
MHz < 16,0
5
MHz < 35,0

dB/100m
dB/100m

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 77 kg/km
120 mm
-40C
+70C
1,10 MJ/m
40,00 kg/km

Norms
Applicable standards:
UL Style:

CC-Link Specification 1.10


CM 75C or PLTC

Application
The CC link (control and communication link) is a field bus system that is used in the area of testing, sensors and actuators. The main target
market is Asia, but the USA and Great Britain also rely more and more on CC link. As an option, a version with power supply cores is available.
It is used particularly in channels.

Part no.

800497, CC-Link communications cable

Dimensions and specifications may be changed without prior notice.

R 157
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
SafetyBUS

FRNC + PUR

Type
Cable structure

Fixed installation, indoor


3x0,75 mm (stranded)

Drag chain applications


3x0,75 mm (stranded)

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 18/24)


PP
wh, bn, gn
Triple core
Polyester foil over stranded bundle
Cu braid, tinned
FRNC
approx. 7,5 mm 0,3 mm
Yellow similar to RAL 1003

Copper, bare (AWG 18/24)


PP
wh, bn, gn
Triple core
Polyester foil over stranded bundle
Cu braid, tinned
PUR
approx. 7,5 mm 0,3 mm
Yellow similar to RAL 1003

110 Ohm 10 Ohm


26 Ohm/km
0,2 GOhm x km
52 Ohm/km max.
45 nF/km nom.
250 V
3 kV
1
MHz < 1,6
5
MHz < 3,4
10
MHz < 5,6
16
MHz < 7,5

110 Ohm 10 Ohm


26 Ohm/km
0,2 GOhm x km
52 Ohm/km max.
45 nF/km nom.
250 V
3 kV
1
MHz < 1,6
5
MHz < 3,4
10
MHz < 5,6
16
MHz < 7,5

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Nominal voltage:
Test voltage:
Attenuation:

dB/Km
dB/Km
dB/Km
dB/Km

dB/Km
dB/Km
dB/Km
dB/Km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 68 kg/km
60 mm
-25C
+80C
0,72 MJ/m
50,00 kg/km

approx. 65 kg/km
60 mm
-40C
+80C
0,76 MJ/m
50,00 kg/km

abutted at SafetyBUS p technical guidelines


copper wires 1.0

abutted at SafetyBUS p technical guidelines


copper wires 1.0

Norms
Applicable standards:

Application
SafetyBUS p is an open bus system for the serial transfer of safety-related data. It is based on the CAN (Controller Area Network) protocol.
From this technology benefit the users in several areas like the automotive industry or the process automation. The above mentioned types
are suitable for fixed installations and as well as for drag chains (PUR).

Part no.

800651, SafetyBus p

800652, SafetyBus p

Dimensions and specifications may be changed without prior notice.

R 158
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
LON BUS

H112 + Y116

Type
Cable structure

Fixed installation, indoor


1x2xAWG 22/1

Mobile use
1x2xAWG 16/19

Inner conductor diameter:


Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Drain wire:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare (AWG 22/1)


PE
wh, bu
Double core
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
yes
FRNC
approx. 4,4 mm 0,3 mm
White

Copper, bare (AWG 16/19)


PVC
wh, bk
Double core
Polyester foil over stranded bundle
PVC
approx. 7,0 mm 0,4 mm
Grey

100 Ohm 10 %
57 Ohm/km
5 GOhm x km
114 Ohm/km max.
45 nF/km nom.
125 V
0,7 kV

85 Ohm 15 %
15,8 Ohm/km
0,02 GOhm x km
31 Ohm/km max.
10 nF/km nom.
300 V
2 kV

approx. 24 kg/km
35 mm
-20C
+75C
0,337 MJ/m
11,00 kg/km

approx. 71 kg/km
85 mm
-20C
+80C
1,25 MJ/m
30,00 kg/km

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Nominal voltage:
Test voltage:

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

Application
The LON bus (Local Operating Network) is a system used in building automation systems. It has the great advantage that it allows usage of
different transmission media. It is used in the interior as hard wiring (H122) and as patch cable (Y116) and must be made in accordance with
DIN EN 50090-2-2 (VDE 0892 Part 2-2:1997-06).

Part no.

802187, LON H122

802188, LON Y116

Dimensions and specifications may be changed without prior notice.

R 159
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
E-BUS

PVC

Type
Cable structure

2-pairs
2x2x0.8 mm

2-pairs
2x2x0.8 mm

Inner conductor:
Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Drain wire:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare
PVC
wh, ye, rd, bk
Star quad
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
yes
PVC
approx. 6,6 mm 0,3 mm
Blue Lilac similar to RAL 4005

Copper, bare
PVC
wh, ye, rd, bk
Star quad
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
yes
PVC
approx. 6,6 mm 0,3 mm
Green similar to RAL 6010

100 Ohm
73,2 Ohm/km
0,1 GOhm x km
146 Ohm/km max.
100 nF/km nom.

100 Ohm
73,2 Ohm/km
0,1 GOhm x km
146 Ohm/km max.
100 nF/km nom.

approx. 54 kg/km
95 mm
-30C
+70C
0,90 MJ/m
25,00 kg/km

approx. 54 kg/km
95 mm
-30C
+70C
0,90 MJ/m
25,00 kg/km

EIB standard

EIB standard

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

Norms
Applicable standards:

Application
The E-bus cable is used for the transmission of bus signals for intelligent systems in buildings. The cables ensure perfect communication in
accordance with EIB regulations (European installation bus). They can be layed over, in, or below the plaster, in pipes and pipe ducts, in dry,
moist, and wet areas, as well as outside, provided they are protected against direct exposure to the sun. Wiring together with high-power
supply cables is possible without limitation. The EIB bus can be used to control lighting, blinds, heating, ventilation, indicator boards, etc.

Part no.

81081, E-BUS

81663, E-BUS

Dimensions and specifications may be changed without prior notice.

R 160
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
E-BUS

FRNC + PVC

Type
Cable structure

2-pairs
2x2x0.8 mm

4-pairs
4x2x0.8 mm

Inner conductor:
Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Drain wire:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare
PE
wh, ye, rd, bk
Star quad
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
yes
FRNC
approx. 6,6 mm 0,3 mm
Blue Lilac similar to RAL 4005

Copper, bare
PVC
wh, ye, rd, gn, bu, bn, wh, wh
Double core
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
yes
PVC
approx. 8,2 mm 0,4 mm
Blue Lilac similar to RAL 4005

100 Ohm
73,2 Ohm/km
0,1 GOhm x km
146 Ohm/km max.
100 nF/km nom.

100 Ohm
73,2 Ohm/km
0,1 GOhm x km
146 Ohm/km max.
100 nF/km nom.

approx. 54 kg/km
95 mm
-30C
+70C
0,58 MJ/m
25,00 kg/km

approx. 92 kg/km
120 mm
-30C
+70C
1,37 MJ/m
41,00 kg/km

EIB standard

EIB standard

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

Norms
Applicable standards:

Application
The E-bus cable is used for the transmission of bus signals for intelligent systems in buildings. The cables ensure perfect communication in
accordance with EIB regulations (European installation bus). They can be layed over, in, or below the plaster, in pipes and pipe ducts, in dry,
moist, and wet areas, as well as outside, provided they are protected against direct exposure to the sun. Wiring together with high-power
supply cables is possible without limitation. The EIB bus can be used to control lighting, blinds, heating, ventilation, indicator boards, etc.

Part no.

80826, E-BUS

81077, E-BUS

Dimensions and specifications may be changed without prior notice.

R 161
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
E-BUS DIRECT BURIAL

PE, ERD

Type
Cable structure

Underground laying
2x2x0.8 mm

Inner conductor:
Core insulation:
Core colours:
Stranding element:
Shielding 1:
Shielding 2:
Total shielding:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare
PE
wh, ye, rd, bk
Star quad
Polyester foil over stranded bundle
Polyester foil, aluminium-lined
PE
approx. 8,8 mm 0,3 mm
Black similar to RAL 9005

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:
Loop resistance:
Mutual capacitance:
Test voltage:

100 Ohm
73,2 Ohm/km
5 GOhm x km
146 Ohm/km max.
55 nF/km nom.
0,8 kV

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

approx. 75 kg/km
130 mm
-20C
+70C
2,00 MJ/m
25,00 kg/km

Norms
Applicable standards:

EIB standard

Application
The E-bus cable is used for the transmission of bus signals for intelligent systems in buildings. The cables ensure perfect communication in
accordance with EIB regulations (European installation bus). They can be layed over, in, or below the plaster, in pipes and pipe ducts, in dry,
moist, and wet areas, as well as outside, provided they are protected against direct exposure to the sun. Wiring together with high-power
supply cables is possible without limitation. The EIB bus can be used to control lighting, blinds, heating, ventilation, indicator boards, etc.

Part no.

802800, E-BUS BURIAL

Dimensions and specifications may be changed without prior notice.

R 162
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BUS Cables
KH-BUS

PVC + FRNC

Type
Cable structure

Hospital-Bus
2x1.5mm (stranded) +
2x2x0.60 mm (solid)

Hospital-Bus
2x1.5mm (stranded) +
2x2x0.60 mm (solid)

Inner conductor, power core:


Inner conductor, data core:
Core insulation, power core:
Core insulation, data core:
Core colours, power core:
Core colours, data core:
Stranding element, data core:
Shielding, data pair:
Drain wire:
Outer sheath material:
Cable external diameter:
Outer sheath colour:

Copper, bare
Copper, tinned
PVC
PE
rd, bu
gn/ye, gy/pk
Double core
PP foil + aluminium-lined foil + PP foil
yes
PVC
approx. 8,0 mm 0,3 mm
Green similar to RAL 6001

Copper, bare
Copper, tinned
PVC
PE
rd, bu
gn/ye, gy/pk
Double core
PP foil + aluminium-lined foil + PP foil
yes
FRNC
approx. 8,0 mm 0,3 mm
Green similar to RAL 6001

0,02 GOhm x km
70 nF/km nom.
2 kV

0,02 GOhm x km
70 nF/km nom.
2 kV

approx. 90 kg/km
120 mm
-30C
+80C
1,01 MJ/m
53,00 kg/km

approx. 93 kg/km
120 mm
-30C
+80C
0,86 MJ/m
53,00 kg/km

Electrical data
Insulation resistance, min.:
Mutual capacitance:
Test voltage:

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Caloric load, approx. value:
Copper weight:

Application
For computer-based patient calling systems, easy and quick installation is an important factor. Therefore a 6-core bus cable is used to connect
the components of the calling system. This cable is used for the transmission of power, data, and voice.

Part no.

81085, KH-BUS

81447, KH-BUS

Dimensions and specifications may be changed without prior notice.

R 163
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Media Technology

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Media Technology
The product range for media equipment
encompasses cables for both indoor and outdoor
use. It guarantees high transmission quality for
xed installations or for mobile use. The diverse
range of products in detail comprises HELUSOUND

audio cables for analogue and digital transmission,


HELULIGHT for the DMX light controller, video
cables, Triax camera cables and special cables as per
your requirements.

S1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description

Page

Audio,

Audio cables with braided shielding

.....................................................................................................................................................

S3

Audio,

Audio cables, multicore, with braided shielding

Audio,

Audio cables with foil shielding, single pair

Audio,

Audio cables, multipaired, pairs with foil shielding

Audio,

Audio cables, multipaired, spirally screened pairs and overall braided shielding

Audio,

AES/EBU digital audio cables, single pair, with spiral screen

Audio,

AES/EBU digital audio cables, single pair, foil/braided shielding

...................................................................................................................

S9

Audio,

AES/EBU digital audio cables, multipaired, pairs with foil shielding and overall foil shielding

.................................................................................

S 10

Audio,

AES/EBU digital audio cables, multipaired, spirally screened pairs and overall foil shielding

......................................................................................................................................

S4

............................................................................................................................................

S5

...................................................................................................................................

S6

................................................................................................

S7

........................................................................................................................

S8

..................................................................................

S 11

.................................................................................................................................................

S 12

........................................................................................................................................................

S 13

..........................................................................................................................................................

S 14

..................................................................................................................................

S 15

Audio & Light,

AES/EBU & DMX patch cable

Audio & Light,

AES/EBU & DMX cables

Audio & Light,

AES/EBU TP DMX 512

Audio & Light,

DMX cables, multicore with spiral screen

Light+Power,

.....................................................................................................................................................................

S 16

HELUSOUND DMX+POWER ................................................................................................................................................................

S 17

Audio,

Instrument cables with spiral screen

....................................................................................................................................................

S 18

Audio,

Microphone cables with spiral screen, paired

Audio,

Microphone cables with braided shielding

Audio,

Microphone cables with braided shielding, star quads

DMX-POWER

.........................................................................................................................................

S 19

.............................................................................................................................................

S 20

..............................................................................................................................

S 21

Loudspeaker Cables ............................................................................................................................................................................

S 22

HELUSOUND 400 PVC,

..........................................................................................................................................

S 23

Audio,

Speaker cables, round

......................................................................................................................................................................

S 24

HELUSOUND 500 PUR ........................................................................................................................................................................

S 25

HELUSOUND 600 FRNC, halogen-free ..............................................................................................................................................

S 26

Audio,

....................................................................................................................................................................

S 27

Loadcable 300/500V + 600/1000V .....................................................................................................................................................

S 28

Video Cables .......................................................................................................................................................................................

S 29

Video,

Video cables, multicore

....................................................................................................................................................................

S 30

Video,

Camera cables

...............................................................................................................................................................................

S 31

Speaker cable, round

Speaker cables, coaxial

S2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Audio
Audio cables with braided shielding

Type
Cable structure

HELUSOUND audio cable analog


2x0,25 + 0,25

Conductor material:
Core insulation:
Core colours:
Stranding element:
Drain wire:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, bare
PVC
rd, wh
2 cores with 1 filler and 1 earth conductor stranded
yes
PVC
approx. 3,4 mm
black

Electrical data
Conductor resistance, max.:
Insulation resistance, min.:

75 Ohm/km
5 MOhm x km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 20 kg/km
35 mm
-25C
+70C
13,5 kg/km

Norms

Halogen-free acc. to EN 50267-2-3


Part no.

Cable structure

400000
400001
400002

2x0,25 + 0,25
2x0,33+0,33
2x0,5+0,33

Conductor
resistance
Ohm / km
< 75,0
< 60,0
< 36,8

Outer diameter
approx. mm
3,4
4,0
5,6

Cop.
weight
kg/km
13,5
16,3
26,1

Weight
approx. kg/km
20,0
26,0
49,0

Dimensions and specifications may be changed without prior notice.

Application
The HELUSOUND audio cable is a 2-core, shielded multipurpose cable with earth conductor. It is particularly suitable for use in microphone,
radio, studio and transmission systems.

S3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Audio
Audio cables, multicore, with braided shielding

Type
Cable structure

HELUSOUND audio cable analog


2x0,26

Conductor material:
Core insulation:
Stranding element:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, bare
PE
pairs stranded
PVC
approx. 5,2 mm
black

Electrical data
Conductor resistance, max.:
Insulation resistance, min.:

73,9 Ohm/km
1 GOhm x km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 37 kg/km
52 mm
-25C
+70C
16,8 kg/km

Norms

Halogen-free acc. to EN 50267-2-3


Part no.

Cable structure

400003
400004
400005
400006
400007
400008
400009
400010

2x0,26
2x0,33
4x0,33
2x0,50
2x0,75
3x0,75
4x0,75
5x0,75

Conductor
resistance
Ohm / km
< 73,9
< 61,6
< 61,6
< 39,0
< 26,0
< 26,0
< 26,0
< 26,0

Outer diameter
approx. mm
5,2
5,3
5,9
5,7
7,2
7,7
8,3
8,9

Cop.
weight
kg/km
16,8
18,2
27,2
22,0
30,0
50,0
60,0
72,0

Weight
approx. kg/km
37,0
38,0
52,0
46,0
70,0
90,0
102,0
120,0

Dimensions and specifications may be changed without prior notice.

Application
The 2-5-core shielded HELUSOUND audio cable with a common PE core insulation, braided shielding and PVC outer sheath is especially well
suited for use in microphone, loudspeaker, radio and transmission systems.

S4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Audio
Audio cables with foil shielding, single pair

Type
Cable structure

Analog audio cables


2x0,22

Conductor material:
Core insulation:
Core colours:
Stranding element:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, tinned
PE
rd, bu
pairs stranded
PVC
approx. 3,4 mm
black

Electrical data
Conductor resistance, max.:
Insulation resistance, min.:

86 Ohm/km
1 GOhm x km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 17 kg/km
35 mm
-25C
+70C
6,6 kg/km

Norms

Halogen-free acc. to EN 50267-2-3

Part no.

400011

Dimensions and specifications may be changed without prior notice.

Application
The 2-core HELUSOUND audio cable is a foil shielded cable with earth conductor. This symmetrical cable is suitable for use in racks and for
studio cabling.

S5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Audio
Audio cables, multipaired, pairs with foil shielding

Type
Cable structure

Analog audio cables


2x2x0,22

Conductor material:
Core insulation:
Core colours:
Stranding element:
Drain wire:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, bare
PE
rd, bu
pairs stranded
yes
PVC
approx. 7,6 mm
black

Electrical data
Conductor resistance, max.:
Insulation resistance, min.:

86 Ohm/km
1 GOhm x km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 72 kg/km
76 mm
-25C
+70C
13,2 kg/km

Norms

Halogen-free acc. to EN 50267-2-3


Part no.

Cable structure

Outer diameter
approx. mm

400012
400013
400014
400015
400016
400017
400018
400019
400020

2x2x0,22
4x2x0,22
8x2x0,22
12x2x0,22
16x2x0,22
20x2x0,22
24x2x0,22
32x2x0,22
40x2x0,22

7,6
9,2
12,2
14,2
16,4
18,4
20,4
22,4
24,6

Cop.
weight
kg/km
13,2
26,0
53,0
79,0
106,0
132,0
158,0
211,0
264,0

Weight
approx. kg/km
72,0
100,0
179,0
248,0
337,0
421,0
493,0
620,0
759,0

Dimensions and specifications may be changed without prior notice.

Application
The HELUSOUND audio cable is an insulated, multi-core audio cable which is screened symmetrically and in pairs. The cable is particularly
suitable for permanent laying in public buildings, such as, e.g. theatres or music stages and for permanent studio installation.

S6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Audio
Audio cables, multipaired, spirally screened pairs and overall braided
shielding

Type
Cable structure

Analog audio cables


12x2x0,14

Analog audio cables


16x2x0,14

Conductor material:
Core insulation:
Stranding element:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, tinned
TPE
pairs stranded
PUR
approx. 12,7 mm
black

Copper, tinned
TPE
pairs stranded
PUR
approx. 14,1 mm
black

150 Ohm/km
100 MOhm x km

150 Ohm/km
100 MOhm x km

Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 190 kg/km


127 mm
-25C
+70C
118,0 kg/km

approx. 247 kg/km


142 mm
-25C
+70C
165,0 kg/km

Norms

Halogen-free acc. to 60754-2

Halogen-free acc. to 60754-2

Part no.

400042

400043

Electrical data
Conductor resistance, max.:
Insulation resistance, min.:

Technical data

Dimensions and specifications may be changed without prior notice.

Application
The multipaired HELUSOUND special sound audio cable has individually shielded pairs and is protected by an additional braided shielding
and ribbed PUR sheath. This cable is particularly suitable for use in mobile radio and transmission systems.

S7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Audio
AES/EBU digital audio cables, single pair, with spiral screen

Type
Cable structure

Digital audio cables


2x0,22

Conductor material:
Core insulation:
Core colours:
Stranding element:
Drain wire:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, bare
PE
rd, bu
2 cores with 1 earth conductor
yes
PVC
approx. 5,0 mm
black

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:

110 Ohm
86 Ohm/km
1 GOhm x km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 35 kg/km
50 mm
-25C
+70C
14,7 kg/km

Norms

Halogen-free acc. to EN 50267-2-3

Part no.

400021

Dimensions and specifications may be changed without prior notice.

Application
The HELUSOUND AES/EBU audio cable is a 2-core, symmetrical and shielded digital sound cable with flexible spiral screen and PVC outer
sheath. The cable is suitable for the transmission of digital audio signals and can therefore, for example, be used for connecting audio
amplifiers, digital mixers, DAT recorders etc.
The cable is also available with PUR outer sheath.

S8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Audio
AES/EBU digital audio cables, single pair, foil/braided shielding

Type
Cable structure

Digital audio cables


2x0,22

Conductor material:
Core insulation:
Core colours:
Stranding element:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, tinned
Cell PE
rd, bu
2 cores with 1 earth conductor
PVC
approx. 6,0 mm
black

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:

110 Ohm
86 Ohm/km
1 GOhm x km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 43 kg/km
60 mm
-25C
+70C
15,7 kg/km

Norms

Halogen-free acc. to EN 50267-2-3


Part no.

Cable structure

Screen

400022
400023
400024

2x0,22
2x0,22
2x0,22

Foil + braid
Foil + braid
Foil

Conductor
resistance
Ohm / km
< 86,0
< 86,0
< 86,0

Outer diameter
approx. mm
6,0
4,5
4,2

Cop.
weight
kg/km
15,7
15,7
7,3

Weight
approx. kg/km
43,0
25,0
18,0

Dimensions and specifications may be changed without prior notice.

Application
The HELUSOUND AES/EBU audio cable is a 2-core, symmetrical and shielded digital sound cable. The cable is available in three different
versions. The standard version is characterised by double shielding; the patch variant has reduced outside diameter and the foil shielded
variant is suitable for the permanent wiring of digital devices. All three versions are suitable for the transmission of digital audio signals.

S9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Audio
AES/EBU digital audio cables, multipaired, pairs with foil shielding and
overall foil shielding

Type
Cable structure

Digital audio cables


2x2x0,22

Conductor material:
Core insulation:
Core colours:
Stranding element:
Drain wire:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, tinned
Cell PE
rd, bu
2 cores with 1 earth conductor
yes
PVC
approx. 9,9 mm
black

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:

110 Ohm
86 Ohm/km
1 GOhm x km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 85 kg/km
100 mm
-25C
+70C
15,4 kg/km

Norms

Halogen-free acc. to EN 50267-2-3


Part no.

Cable structure

Outer diameter
approx. mm

400025
400026
400027
400028
400029

2x2x0,22
4x2x0,22
6x2x0,22
8x2x0,22
12x2x0,22

9,9
11,8
14,9
16,1
19,1

Cop.
weight
kg/km
15,4
29,0
42,0
55,0
81,0

Weight
approx. kg/km
85,0
119,0
195,0
232,0
330,0

Dimensions and specifications may be changed without prior notice.

Application
The multipaired, digital HELUSOUND AES/EBU audio cable is characterised by its shielding in pairs, its element sheaths and by the additional
overall sheath. This cable is suitable for the transmission of digital audio signals.

S 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Audio
AES/EBU digital audio cables, multipaired, spirally screened pairs and overall
foil shielding

Type
Cable structure

Digital audio cables


12x2x0,22

Conductor material:
Core insulation:
Core colours:
Stranding element:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, bare
Cell PE
rd, bu
2 cores with 1 earth conductor
PVC
approx. 17,0 mm
black

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:

110 Ohm
86 Ohm/km
1 GOhm x km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 320 kg/km


170 mm
-20C
+70C
171,0 kg/km

Norms

Halogen-free acc. to EN 50267-2-3

Part no.

400030

Dimensions and specifications may be changed without prior notice.

Application
The multipaired, digital HELUSOUND AES/EBU audio cable is characterised by its shielding in pairs, its element sheaths and by the additional
overall sheath. This cable is suitable for the transmission of digital audio signals.

S 11
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Audio & Light


AES/EBU & DMX patch cable

Type
Cable structure

DMX cables
2x0,22

Conductor material:
Core insulation:
Core colours:
Stranding element:
Drain wire:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, tinned
Cell PE
rd, bu
2 cores with textile filler stranded
yes
PVC
approx. 5,0 mm
blue

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:

110 Ohm
80 Ohm/km
5 GOhm x km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 33 kg/km
50 mm
-30C
+70C
14,0 kg/km

Part no.

400031

Dimensions and specifications may be changed without prior notice.

Application
The 2-core HELUSOUND AES/EBU & DMX patch cable is foil shielded and optimally protected against external interference by its copper
spiral screen. This cable is suitable for indoor use for permanent laying for the control of lighting systems or for patching in studio technology.

S 12
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Audio & Light


AES/EBU & DMX cables

Type
Cable structure

DMX cables
2x0,34

DMX cables
4x0,34

Conductor material:
Core insulation:
Core colours:
Stranding element:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, bare
Cell PE
rd, wh
2 cores with textile filler stranded
PVC
approx. 6,4 mm
black

Copper, bare
PE
wh,gn,bn,ye
Star quad
PVC
approx. 7,0 mm
black

110 Ohm
53 Ohm/km
10 GOhm x km

110 Ohm
53 Ohm/km
5 GOhm x km

Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 50 kg/km
64 mm
-30C
+70C
18,0 kg/km

approx. 65 kg/km
70 mm
-30C
+70C
29,0 kg/km

Part no.

400032

400033

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:

Technical data

Dimensions and specifications may be changed without prior notice.

Application
The 2-core HELUSOUND AES/EBU & DMX patch cable is protected against external interference by its copper spiral screen. This cable is
suitable for permanent laying for the control of lighting systems or for connecting digital audio amplifiers. It can be installed indoors and
outdoors.

S 13
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Audio & Light


AES/EBU TP DMX 512

Type
Cable structure

DMX cables
2x2x0,22

Conductor material:
Core insulation:
Core colours:
Stranding element:
Drain wire:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, tinned
Cell PE
or/wh, bu/wh
pairs stranded
yes
PVC
approx. 8,0 mm
black

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:

110 Ohm
85 Ohm/km
100 GOhm x km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 76 kg/km
80 mm
-25C
+70C
38,0 kg/km

Part no.

400034

Dimensions and specifications may be changed without prior notice.

Application
The 4-core HELUSOUND AES/EBU & DMX cable is protected against external interference by its AL/PT foil, its copper spiral screen and its
PVC outer sheath. This cable is suitable for controlling all types of digital equipment.

S 14
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Audio & Light


DMX cables, multicore with spiral screen

Type
Cable structure

DMX cables
2x0,22+0,22

Conductor material:
Core insulation:
Core colours:
Stranding element:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, tinned
PE spumed
wh,bu+rd
pair and core stranded together
PVC
approx. 6,4 mm
black

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:

110 Ohm
86 Ohm/km
1 MOhm x km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 79 kg/km
64 mm
-25C
+70C
66,0 kg/km

Norms

Halogen-free acc. to EN 50267-2-3

Part no.

400035

Dimensions and specifications may be changed without prior notice.

Application
The 3-core, shielded HELUSOUND digital sound cable consists of a symmetrical pair and an additional third core. A double spiral screen and
the PVC outer sheath protect the cable against electrical interference. This AES/EBU and DMX compliant (110 Ohm) special cable is suitable
for the transmission of digital audio signals and can therefore, for example, be used for connecting digital mixers, audio amplifiers, DAT
recorders, light and scanner systems etc.

S 15
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Light+Power
DMX-POWER

Type
Cable structure

DMX cables
(1x2x0,24)+2x1,0

Conductor material:
Core insulation:
Stranding element:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, bare
Foam-skin-PE
Double core
PVC
approx. 7,4 mm
black

Electrical data
Characteristic impedance:

110 Ohm

Technical data
Weight:
Copper weight:

approx. 74 kg/km
35,0 kg/km

Part no.

400081

Dimensions and specifications may be changed without prior notice.

Application
The hybrid DMX Power cable is used in the professional DMX light controller. It transmits power for the light and control signals for the
movement. The cable is compact, flexible and easy to process.

S 16
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUSOUND DMX+POWER

Type
Cable structure

DMX cables


Conductor material:
Core insulation:
Core insulation 2:
Core colours:
Stranding element:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, bare
Foam-Skin-PE (DMX), PVC (Power)
PVC
red, white (DMX); brown, blue, green/yellow (Power)
DMX-Element together with Power-Element and filler stranded
PVC flexible at low temperatures
approx. 13,2 mm
black

Electrical data
Characteristic impedance:
Conductor resistance, max.:
Insulation resistance, min.:

110 Ohm
53 Ohm/km
10 GOhm x km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 50 kg/km
64 mm
-30C
+70C
60,5 kg/km

Part no.

400151

Dimensions and specifications may be changed without prior notice.

Application
The HELUSOUND DMX+POWER hybrid cable combines a shielded light control wire and the power supply wire. The DMX-cable, which is
shielded by a tin-coated copper braiding is perfectly suited for the control of light systems and mixing boards (110 Ohm characteristic
intrinsic impedance). It highlights a soft PVC insulation and it is qualified for the use at indoor and outdoor installations. The DMX cable can
also be used for the transmission of audio signals such as a microphone wire or as a power supply wire for active loudspeaker systems.

S 17
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Audio
Instrument cables with spiral screen

Type
Cable structure

Instrument cables
1x0,22

Instrument cables
1x0,38

Conductor material:
Core insulation:
Drain wire:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, bare
Foam-skin-PE
PVC
approx. 5,9 mm
black

Copper, bare
Cell PE
yes
PVC
approx. 7,0 mm
black

86 Ohm/km
1 GOhm x km

55 Ohm/km
1 GOhm x km

Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 44 kg/km
60 mm
-25C
+70C
7,9 kg/km

approx. 55 kg/km
70 mm
-25C
+70C
29,0 kg/km

Norms

Halogen-free acc. to EN 50267-2-3

Halogen-free acc. to EN 50267-2-3

Part no.

400036

400037

Electrical data
Conductor resistance, max.:
Insulation resistance, min.:

Technical data

Dimensions and specifications may be changed without prior notice.

Application
The HELUSOUND instrument cable with spiral screen is a non-symmetrical, double shielded cable. This cable is specially suitable for connecting
high ohmic components such as synthesisers, keyboards or guitars in professional stage and studio operation. The high-quality 1x0.38 special
cable has an increased cross-section, a semi-conductor layer and a double spiral screen, which makes it suitable for the most stringent
requirements of professional stages and studios.

S 18
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Audio
Microphone cables with spiral screen, paired

Type
Cable structure

Microphone cable
2x0,22

Microphone cable
2x0,15

Conductor material:
Core insulation:
Core colours:
Stranding element:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, bare
PE
rd, bu
pairs stranded
PVC
approx. 6,0 mm
black

Copper, bare
PVC
rd, wh
pairs stranded
PVC
approx. 4,2 mm
black

86 Ohm/km
1 GOhm x km

120 Ohm/km
1 GOhm x km

Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 55 kg/km
60 mm
-25C
+70C
12,1 kg/km

approx. 27 kg/km
42 mm
-25C
+70C
14,0 kg/km

Norms

Halogen-free acc. to EN 50267-2-3

Halogen-free acc. to EN 50267-2-3

Part no.

400038

400039

Electrical data
Conductor resistance, max.:
Insulation resistance, min.:

Technical data

Dimensions and specifications may be changed without prior notice.

Application
The 2-core HELUSOUND microphone cable with spiral screen is suitable for use in professional stage and studio operation. The microphone
cable 2x0.15 has a double spiral screen made of bare copper wires.

S 19
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Audio
Microphone cables with braided shielding

Type
Cable structure

Microphone cable
2x0,34

Microphone cable
2x0,50

Conductor material:
Core insulation:
Core colours:
Stranding element:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, bare
PE
rd, bu
2 cores with textile filler stranded
PVC
approx. 6,5 mm
black

Copper, bare
PE
rd, wh
2 cores with textile filler stranded
PVC
approx. 6,7 mm
black

53 Ohm/km
1 GOhm x km

37 Ohm/km
1 GOhm x km

Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 30 kg/km
65 mm
-30C
+70C
15,2 kg/km

approx. 59 kg/km
67 mm
-30C
+70C
37,0 kg/km

Part no.

400040

400080

Electrical data
Conductor resistance, max.:
Insulation resistance, min.:

Technical data

Dimensions and specifications may be changed without prior notice.

Application
The 2-core HELUSOUND microphone cable with copper braided shield is suitable for use in professional stage and studio operation and for
permanent installation. The cable is distinguished by its very flexible PVC sheath.

S 20
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Audio
Microphone cables with braided shielding, star quads

Type
Cable structure

Microphone cable
4x0,22

Conductor material:
Core insulation:
Core colours:
Stranding element:
Drain wire:
Inner sheath material:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, bare
PE
rd,bu,gn,bk
Star quad
AWG 26/7, Kupfer verzinnt
PE
PVC
approx. 6,1 mm
black

Electrical data
Conductor resistance, max.:
Insulation resistance, min.:

86 Ohm/km
1 GOhm x km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 50 kg/km
62 mm
-25C
+70C
25,0 kg/km

Norms

Halogen-free acc. to EN 50267-2-3

Part no.

400041

Dimensions and specifications may be changed without prior notice.

Application
The 4-core HELUSOUND microphone cable is stranded in star quads and suitable for special application due to its earth conductor and
braided shielding. Among other things, it is used as a stereo cable in the area of professional studio and microphone technology.

S 21
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Loudspeaker Cables


Cross section (mm)
Part no.

2 x 0,5
40180

2 x 0,5
40023

2 x 0,75
40181

2 x 0,75
40024

2 x 1,5
40182

2 x 1,5
40025

2 x 2,5
40183

2 x 2,5
40026

2x4
40184

2x4
40027

16 x 0,20
2,1 x 4,7
PVC
black/red
15

24 x 0,20
2,2 x 4,9
PVC
transparent
20

24 x 0,20
2,2 x 4,9
PVC
black/red
20

28 x 0,25
2,6 x 5,5
PVC
transparent
37

28 x 0,25
2,6 x 5,5
PVC
black/red
37

48 x 0,25
3,3 x 7,0
PVC
transparent
63

48 x 0,25
3,3 x 7,0
PVC
black/red
63

55 x 0,30
4,3 x 8,2
PVC
transparent
80

55 x 0,30
4,3 x 8,2
PVC
black/red
80

70
47

70
47

47
60

47
60

23
67

23
67

14
67

14
67

9
64

9
64

0,67
0,79
0,85
0,8

0,67
0,79
0,85
0,8

0,61
0,73
0,73
0,67

0,61
0,73
0,73
0,67

0,54
0,59
0,59
0,52

0,54
0,59
0,59
0,52

0,54
0,62
0,62
0,56

0,54
0,62
0,62
0,56

0,58
0,65
0,65
0,59

0,58
0,65
0,65
0,59

9,6

9,6

14,4

14,4

28,8

28,8

48,0

48,0

76,8

76,8

Cable structure
Conductor material: Copper litz wire, bare
Identification: Grooves
Cond. make-up
16 x 0,20
Insulation h x w mm
2,1 x 4,7
Jacket material
PVC
Jacket colour
transparent
Weight approx. kg / km
15
Electrical characteristics
Loop resistance
max. (Ohm/km)
Capacitance pF/m
Inductance H/m at
1 kHz
10 kHz
100 kHz
1000 kHz
Copper weight kg/km


Cross section (mm)
Part no.

2 x 1,5
40185

2 x 2,5
40186

2x4
40187

2x6
40188

2 x 10
40189

322 x 0,10
3,6 x 7,5
PVC
transparent
60

511 x 0,10
5 x 10,2
PVC
transparent
79

777 x 0,10
6,1 x 12,5
PVC
transparent
136

1273 x 0,10
7,0 x 15,0
PVC
transparent
254

23
67

14
53

9
50

6
54

3
59

0,54
0,61
0,62
0,55

0,48
0,55
0,59
0,54

0,49
0,56
0,6
0,56

0,46
0,54
0,56
0,53

0,45
0,53
0,56
0,52

28,8

48,0

76,8

115,2

192,0

Cable structure
Conductor material: Bare copper litz wire, highly flexible
Identification: Stripes
Cond. make-up
189 x 0,10
Insulation h x w mm
3,1 x 6,5
Jacket material
PVC
Jacket colour
transparent
Weight approx. kg / km
41
Electrical characteristics
Loop resistance
max. (Ohm/km)
Capacitance pF/m
Inductance H/m at
1 kHz
10 kHz
100 kHz
1000 kHz
Copper weight kg/km

Dimensions and specifications may be changed without prior notice. (RM01)

Note
The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties
of lacquers.

S 22
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUSOUND 400 PVC


Speaker cables, round

Type
Cable structure

Speaker cable HELUSOUND 400


2x1,5

Conductor material:
Core insulation:
Core colours:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, bare
PVC
rd, bk
PVC
approx. 6,6 mm
Black

Electrical data
Conductor resistance, max.:

12,7 Ohm/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 73,4 kg/km


33 mm
-10C
+70C
28,8 kg/km


Part no.

Cable structure

400089
400090
400091
400092
400093
400060
400094

2x1,5
2x2,5
2x4,0
4x2,5
4x4,0
8x2,5
8x4,0

Conductor
resistance
Ohm / km
< 12,7
< 7,9
< 4,9
< 7,9
< 4,9
< 7,9
< 4,9

Outer diameter
approx. mm
6,6
7,5
9,4
8,8
11,6
13,5
16,8

Cop.
weight
kg/km
28,8
48,0
76,8
96,0
153,6
192,0
307,2

Weight
approx. kg/km
73,4
106,9
163,7
169,3
272,4
349,0
541,6

Dimensions and specifications may be changed without prior notice.

Application
All products of the HELUSOUND 400 LOUDSPEAKER series impress with their extremely high flexibility. 0.15 strands and a very soft PVC outer
sheath make this possible. These cables are particularly used in mobile applications, in studios and in conference technology.

S 23
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Audio
Speaker cable, round

Type
Cable structure

Speaker cable
2x1,5

Conductor material:
Core insulation:
Core colours:
Stranding element:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, bare
PVC
rd, bu
pairs stranded
PVC
approx. 7,0 mm
Black

Electrical data
Conductor resistance, max.:
Insulation resistance, min.:

13,3 Ohm/km
5 MOhm x km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 74 kg/km
70 mm
-25C
+70C
30,0 kg/km

Norms

Halogen-free acc. to EN 50267-2-3


Part no.

Cable structure

400056
400057
400058
400059

2x1,5
2x2,5
2x4,0
4x2,5

Conductor
resistance
Ohm / km
< 13,3
< 7,98
< 4,95
< 7,98

Outer diameter
approx. mm
7,0
7,6
11,0
10,0

Cop.
weight
kg/km
30,0
50,0
80,0
100,0

Weight
approx. kg/km
74,0
97,0
187,0
176,0

Dimensions and specifications may be changed without prior notice.

Application
The HELUSOUND loudspeaker cable suits for outdoor application as well as fixed installation. Due to its robustness and reeling characteristic,
it is in use in all kind of acoustic irradiation systems, also in stage and building control systems.

S 24
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUSOUND 500 PUR

Type
Cable structure

Speaker cable HELUSOUND 500 PUR


2x1,5

Conductor material:
Core insulation:
Core colours:
Stranding element:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, bare
PVC
rd, bk
Double core
PUR
approx. 6,6 mm
Black

Electrical data
Conductor resistance, max.:

12,7 Ohm/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 66,9 kg/km


33 mm
-25C
+80C
28,8 kg/km


Part no.

Cable structure

400109
400110
400111
400112
400113
400114
400115

2x1,5
2x2,5
2x4,0
4x2,5
4x4,0
8x2,5
8x4,0

Conductor
resistance
Ohm / km
< 12,7
< 7,9
< 4,9
< 7,9
< 4,9
< 7,9
< 4,9

Outer diameter
approx. mm
6,6
7,5
9,4
8,8
11,6
13,5
16,8

Cop.
weight
kg/km
28,8
48,0
76,8
96,0
153,6
192,0
307,2

Weight
approx. kg/km
66,9
98,5
150,2
159,1
253,0
332,1
499,5

Dimensions and specifications may be changed without prior notice.

Application
All products of the HELUSOUND 400 LOUDSPEAKER series impress with their extremely high flexibility. 0.15 strands and a very soft PVC outer
sheath make this possible. These cables are particularly used in mobile applications, in studios and in conference technology.

S 25
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUSOUND 600 FRNC, halogen-free

Type
Cable structure

Speaker cable HELUSOUND 600 FRNC


2x1,5

Conductor material:
Core insulation:
Core colours:
Stranding element:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, bare
FRNC
rd, bk
Double core
FRNC
approx. 6,6 mm
Black

Electrical data
Conductor resistance, max.:

12,7 Ohm/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 77 kg/km
33 mm
-5C
+70C
28,8 kg/km


Part no.

Cable structure

400116
400117
400118
400119
400120
400121
400122

2x1,5
2x2,5
2x4,0
4x2,5
4x4,0
8x2,5
8x4,0

Conductor
resistance
Ohm / km
< 12,7
< 7,9
< 4,9
< 7,9
< 4,9
< 7,9
< 4,9

Outer diameter
approx. mm
6,6
7,5
9,4
8,8
11,6
13,5
16,8

Cop.
weight
kg/km
28,8
48,0
76,8
96,0
153,6
192,0
307,2

Weight
approx. kg/km
77,0
105,6
166,9
161,5
271,6
338,6
531,5

Dimensions and specifications may be changed without prior notice.

S 26
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Audio
Speaker cables, coaxial

Type
Cable structure

Speaker cable
1x2,5

Speaker cable
1x4,0

Conductor material:
Core insulation:
Core colours:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, bare
PVC
Black
PVC
approx. 6,8 mm
Black

Copper, bare
PVC
Black
PVC
approx. 7,9 mm
Black

7,98 Ohm/km
5 MOhm x km

4,95 Ohm/km
5 MOhm x km

Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 84 kg/km
68 mm
-25C
+70C
52,0 kg/km

approx. 129 kg/km


80 mm
-25C
+70C
87,0 kg/km

Norms

Halogen-free acc. to EN 50267-2-3

Halogen-free acc. to EN 50267-2-3

Part no.

400061

400062

Electrical data
Conductor resistance, max.:
Insulation resistance, min.:

Technical data

Dimensions and specifications may be changed without prior notice.

Application
The coaxial HELUSOUND speaker cable is protected by dual spiral screens in opposite directions and outer sheath. As well as robustness and
good winding capability its design is particularly distinguished by high flexibility and small dimensions.

S 27
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Loadcable 300/500V + 600/1000V

Type
Cable structure

Loadcable 300V/500V/0,6kV/1kV


Conductor material:
Core insulation:
Core colours:
Stranding element:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, bare
PVC flexible at low temperatures
black number coded + gn/ye
14 cores stranded
PVC flexible at low temperatures
approx. 13,4 mm
black

Electrical data
Conductor resistance, max.:

13,3 Ohm/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 322 kg/km


53,6 mm
-40C
+80C
201,6 kg/km

Loadcable 300/500V
Part no.

Cable structure

400143
400144
400145
400146

14 G 1,5
18 G 1,5
14 G 2,5
18 G 2,5

Conductor
resistance
Ohm / km
< 13,3
< 13,3
< 7,98
< 7,98

Outer diameter
approx. mm

Conductor
resistance
Ohm / km
< 13,3
< 13,3
< 7,98
< 7,98

Outer diameter
approx. mm

13,4
15,2
16,6
19,0

Cop.
weight
kg/km
201,6
259,2
336,0
432,0

Weight
approx. kg/km

Cop.
weight
kg/km
201,6
259,2
336,0
432,0

Weight
approx. kg/km

322,0
422,0
487,0
634,0

Loadcable 600/1000V
Part no.

Cable structure

400147
400148
400149
400150

14 G 1,5
18 G 1,5
14 G 2,5
18 G 2,5

17,7
20,2
20,0
22,6

430,0
560,0
604,0
778,0

Dimensions and specifications may be changed without prior notice.

Application
The extremely flexible load cables U0/U 300/500V and load cables U0/U 600/1000V are used for common mechanical demands for professional
stage light systems and other elecrical load circuits from 500V to 1000V. The flexibility is archieved by very fine wire stranding design with
0.15mm flexible strands. The core and sheath insulation are made of cold-flexible PVC; this is also available as a customized product.

S 28
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Video Cables


used as

Indoors

Type
Part no.

0,6/2,8
40022

Cable structure
Inner conductor diameter mm
Insulation mm
1st Outer conductor

approx. mm
Inner steath/Foil
approx. mm
2nd Outer conductor
approx. mm
Outer jacket
Jacket colour
Outer approx. mm
Min. bending radius approx. mm
Weight approx. kg / km
Electrical characteristics
Impedance (Ohm)
Attenuation at 20C
(dB/100m)
1 MHz
5 MHz
7 MHz
10 MHz
50 MHz
100 MHz
Propagation velocity v/c
DC resistanceat 20C
Inner conductor max. Ohm/km
Outer conductor max. Ohm/km
Capacitance pF/m
Test voltage (50 Hz, kV eff.)
Working voltageat (kV)
Pulse operation
HF-operation (peak value)
DC operation
Screening efficiency (dB)
50 and 900 MHz
Copper weight kg/km

Indoors,
Indoors
underground
1,0/6,6
1.0/6.6 2YD
40056
40175

Indoors

Indoors

Indoors

1,0/6,6
40173

Indoors,
Indoors
underground
1.0/6.6D
0.6L/3.7
40073
40170

0,6/3,7
40171

1.0/6.6D
40174

Indoors,
outdoors
0,6L/3,7+2x0,75
40028

0,6
Copper, bare
2,8 Cell PE
Polyester foil
coated with
aluminium on
both sides
Tinned copper
braid
FRNC
green
4,3
25
24

1
Copper, bare
6,4 PE
Bare copper
braid

1
Copper, bare
6,4 PE
Bare copper
braid

1
Copper, bare
6,4 PE
Bare copper
braid

1
Copper, bare
6,4 PE
Bare copper
braid

0,2
Copper, bare
3,7 PE
Bare copper
braid

0,6
Copper, bare
3,7 PE
Bare copper
braid

1
Copper, bare
6,4 PE
Bare copper
braid

0,6
Copper, bare
3,7 PE
Bare copper
braid

7
no

7
no

4,3
no

PVC
green
6,1
30
48

PVC
green
6,1
30
48

7
Foil
Bare copper
braid
7,6
PVC
green
9,0
50
128

PVC
green
8,8
45
95

7
Foil
Bare copper
braid
7,6
PE
black
9,0
50
125

4,2
no

PE
black
8,8
45
93

7
PE
8,5
Bare copper
braid
9,1
PVC
green
11,0
55
151

75 2

75 1

75 1

75 1

75 1

75 1

75 1

75 1

75 3

0,9
2,2
2,6
3,2
7,5
10,2
0,8

0,6
1,3
2
0,66

0,6
1,4
2
0,66

0,6
1,3
2
0,66

0,6
1,4
2
0,66

1,2
2,6
3,6
0,66

1,1
2,5
3,5
0,66

0,6
1,4
2
0,66

1,1
2,5
3,5
0

63
21
54
3,5

22
7,5
67
7

24
6,5
67
7

22
7,5
67
7

24
3,5
67
7

83
12,5
67
4,2

63
13
67
4,2

24
3,5
67
7

63
13
67
4

6
3
14

6
3
14

6
3
14

6
3
14

3,6
1,8
8

3,6
1,8
8

6
3
14

90
11,0

32,0

78,0

32,0

78,0

22,0

22,0

78,0

38,0

PVC
black
11,8
50
0

Dimensions and specifications may be changed without prior notice. (RM01)

Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties
of lacquers.
ALPR=Polyesterfoil coated with Aluminium on both sides
bl=Bare, bk=Black, Cu=Copper, D=2xbraiding, FRNC=Flame Retardant Non-Corrosive, G=Braid, gn=Green, PE=Polyethylene, PEE=Cell-PE,
PVC=Polyvinylchloride

S 29
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Video
Video cables, multicore

Type
Cable structure

Video Cables
3x(0,6/2,8)

Conductor material:
Core insulation:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, bare
Cell PE
PVC
approx. 12,9 mm
Black

Electrical data
Characteristic impedance:
Inner conductor resistance, max.:

75 Ohm
65 Ohm/km

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 178 kg/km


130 mm
-25C
+70C
49,0 kg/km

Norms

Halogen-free acc. to EN 50267-2-3


Part no.

Cable structure

Outer diameter
approx. mm

400068
400069
400070
400071
400072

3x(0,6/2,8)
4x(0,6/2,8)
5x(0,6/2,8)
6x(0,6/2,8)
7x(0,6/2,8)

12,9
14,1
15,3
16,7
16,7

Cop.
weight
kg/km
49,0
65,0
81,0
97,0
113,0

Weight
approx. kg/km
178,0
214,0
259,0
295,0
310,0

Dimensions and specifications may be changed without prior notice.

Application
The multi-core, coaxial HELUKABEL video cable is distinguished by 75 Ohm, cell PE insulation, AL foil and braided shielding, PVC element
sheath and outer sheath. Alternative we also offer a halogen-free and flame-resistant version. As example it is suitable for the parallel
transmission of signals (e.g. RGB).

S 30
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Video
Camera cables

Type
Cable structure

Camera Cables
Triax 8

Conductor material:
Core insulation:
Sheath material:
Cable external diameter:
Sheath colour:

Copper, silvered
PE
PUR
approx. 8,5 mm
Red

Electrical data
Characteristic impedance:

75 Ohm

Technical data
Weight:
Min. bending radius for laying:
Operating temperature range min.:
Operating temperature range max.:
Copper weight:

approx. 95 kg/km
80 mm
-30C
+80C
55,0 kg/km


Part no.

Cable structure

400073
400074
400075
400076
400077
400078

Triax 8
Triax 11
Triax 14
Triax 8 flex
Triax 11 flex
Triax 14 flex

Conductor
insulation
mm
4,5
6,5
9,7
4,5
6,1
9,7

Outer diameter
approx. mm
8,5
11,0
14,4
8,5
11,2
14,4

Cop.
weight
kg/km
55,0
80,0
128,0
55,0
80,0
133,0

Weight
approx. kg/km
95,0
150,0
235,0
105,0
160,0
250,0

Dimensions and specifications may be changed without prior notice.

Application
The HELUKABEL Triax cable ensures the optimal transmission of image signals. This is possible because of the low attenuation values, thick
cross-braided shielding and an especially rugged outer sheath. For the Flex variant, the PVC inner and outer sheath are replaced by TPE to
guarantee greater flexibility. The Triax cables are primarily used to connect video cameras and image transmission systems and are suitable
for mobile use.

S 31
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Special Cables

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Special Cables

T1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Special Cables
The name HELUKABEL stands for standard
cables and lines, cables for data technology, preassembled cables, cable accessories and also
special cables such as system cables and all types
of customised special solutions. And weve been
doing it for 30 years.
We design, construct, and produce insulation
and sheath materials for standard to high tech
applications, including PVC, PE, PP, TPE-E, TPE-O,
PUR, silicon, uoro-plastics, halogen-free polymers,
to name just a few. Our cables meet requirements
in terms of reelability, suitability for drag chains,
increasingly high speed and acceleration, as
well as extreme alternating bending cycles for a
minimum bending radius, and resistance to rough
environmental conditions regarding high and low
temperatures, humidity, oils, petrol and other
chemicals.
Our qualied staff in the Special Cables department
would be happy to advise you on an individual
basis and develop and design your leads. We set
great store by providing the right line for the right
purpose. Depending on the type of cable, we can
deliver in as fast as 4 6 weeks for a minimum
quantity of 100 m.
Just ask us. Our tailor-made range of products will
win you over.

T2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description

Page

Single Conductors
TOPFLEX 303 X07V-K-Y,double insulation 0,6/1kV flexible PVC single core, oil resistant....................................................................................
TOPFLEX 300,high flexible PVC single core, 0,6/1kV for drag chain and free move application.............................................................................
TOPFLEX 1002,flexible double insulated single core 1000V...................................................................................................................
TOPFLEX 302 / 302-UL,very high flexible PVC single core double insulated 0,6/1kV.................................................................................
TOPFLEX 301 / 301-C,unscreened(double insulated)/ screened high flexible PUR single core 0,6/1kV for drag chain application......................
TOPFLEX 304 / 304-C,unscreened(double insulated)/ screened high flexible PVC single core 0,6/1kV for drag chain application......................
GALVANICABLE ,high-current cable, high flexible and halogen-free..................................................................................................................

T 10
T 11

Trailing Cables
Flugzeugheber-T,trailing, PUR..............................................................................................................................................................
BAULIFTKABEL B101 / B102 / B103,to be used at plant elevators...............................................................................................................

T 13
T 14

Cables for Photovoltaic Installations


SOLARFLEX -X PV1-F.................................................................................................................................................................
SOLARFLEX -X PV1-F TWIN.............................................................................................................................................................

T 18
T 19

Cables for Wind Power Stations


HELUWIND WK 103w-T, WK 103w EMC D-T,UV-resistant, UL/CSA-Style 10678/21179 Single-/Multicore...................................................
HELUWIND WK 103k-T, WK 103k EMC D-T,UV-resistant, UL/CSA-Style 10269/2570 Single-/Multicore, screened/unscreened,.........................
HELUWIND WK 135-T, WK 135 D-EMC T,UV-resistant, UL/CSA-Style** 10553 / 20234, Single-/Multicore 90C (80C acc. to UL), suitable for offshore.
HELUWIND WK 137-T / WK 137 EMV D-T ,UV-resistant, suitable for offshore, UL/CSA-Style 10553/20234, Single-/Multicore,
90C, (80C according to UL) ...............................................................................................................................................................
HELUWIND WK 300w-Torsion 1,8/3kV,UV-resistant............................................................................................................................
HELUWIND WK 305-Torsion 1,8/3kV,UV-resistant, suitable for offshore....................................................................................................
HELUWIND WK H07BN4-F WIND-Torsion,Torsion +/- 150/1m, UV-resistant, 750V/90C...............................................................................
HELUWIND WK 101 H,0,6/1kV halogen-free............................................................................................................................................
HELUWIND WK Fire Alarm Cable-Torsion,halogen-free, FT1, 24V...........................................................................................................
HELUWIND WK-NTSCGEWOEU-Torsion,3,6 / 6kV................................................................................................................................
HELUWIND WK DLO 2kV,FT4, UV-resistant, UL44 1kV, 90C, VW-1, LS, MSHA.....................................................................................................
HELUWIND WK Powerline ALU 105C robust,0,6/1kV or 1,8/3kV..........................................................................................................
HELUWIND WK THERMFLEX 145,halogen-free, +145C...........................................................................................................................
HELUWIND WK (N)A2XH,0,6/1kV, halogen-free.......................................................................................................................................

FT4

Sensor actuator and distributor Cables


SENSORFLEX,sensor actuator cable, PVC, PUR, PVC/PUR............................................................................................................................
VERTEILERFLEX two-approvals,sensor actuator and distributor cables PVC, PUR, PVC/PUR.......................................................................
VERTEILERFLEX, for sensor actuator distributor boxes, PVC, PUR or PVC/PUR......................................................................................................
SENSORFLEX-H,sensor actuator cables, halogen-free, high flexible drag chain cable, PUR, mantle EVA +125C..........................................................
Cables for airport 400 Hz

AIRPORT 400 Hz,trailing, PUR, halogen-free, flame retardant..........................................................................................................................


AIRPORT 400 Hz,trailing, PUR, halogen-free, flame retardant..........................................................................................................................

Truck Cables

HELUTRUCK 270,with ADR-approval, PVC low voltage cable for commercial vehicles............................................................................................

HELUTRUCK 271,with ADR-approval, PUR low voltage cable for commercial vehicles............................................................................................
HELUTRUCK 272 / 273,Flat cable for the sideways lighting with GGVS-authorization, Battery cable, battery charging cable............................................

T 5
T 6
T 7
T 8
T 9

T 27
T 28
T 29
T 30
T 31
T 32
T 33
T 34
T 35
T 36
T 37
T 38
T 39
T 40
T 42
T 43
T 45
T 46
T 49
T 50
T 52
T 53
T 54

T3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX 303 X07V-K-Y


TOPFLEX 300
TOPFLEX 1002
TOPFLEX 302 / 302-UL
TOPFLEX 301 / 301-C
TOPFLEX 304 / 304-C
GALVANICABLE
Photo: HELUKABEL

Single Conductors
These lines are specially designed for use as
connecting cables in energy supply chains,
handling equipment, robots, machine tools, and
manufacturing and processing machines, and in
almost all areas of exible use with free movement.

Optimised insulation materials ensure resistance


to oil, greases, coolants, hydraulic liquids, as
well as countless alkalis and solvents. Optimised
exterior diameters, reduced weights, and outstanding torsion characteristics are the standout
features of many of the single cores listed here.

T4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX 303 X07V-K-Y double insulation 0,6/1kV flexible PVC


single core, oil resistant


Technical data

Cable structure

Properties

Special PVC single-core cable with double


insulation and oil-resistant sheath
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage
U0/U 600/1000 V
A.C. test voltage, 50 Hz
3000 V
Insulation resistance
min. 20 MOhm/km
Minimum bending radius
for flexible installation
approx. 12 cable

Bare copper, fine wire conductor to


DINVDE0295 cl.5 and IEC60228 cl.5
Special PVC core insulation, cold-resistant
colour black / green-yellow
Special PVC sheath, TM5 acc. to
HD21.1S2/A16
Sheath colour grey


These cables have been tested according


to VDE207 and VDE0473 and found to be
totally oil resistant
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Improved mechanical protection due the
double insulation

Application
This cable is used for conditions of increased mechanical stress. For flexible use with free movement without tensile stress or forced
movements in dry, moist and wet environments, but not suitable for use outdoors.
The cable may be laid in trays, troughs and channels.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


core-/sheath-color black/grey
Part no.
75460
75461
75462
75463
75464
75465
75466
75467
72184
72185
75468
74221
72082

No.cores x
cross-sec.
mm
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300

Outer
Cop.
approx. mm weight
kg/km
8,5
58,0
9,5
96,0
11,5
154,0
14,0
240,0
15,0
336,0
17,5
480,0
20,0
672,0
22,0
912,0
23,5
1152,0
26,5
1440,0
29,0
1776,0
31,0
2304,0
35,0
2880,0

Weight
approx.
kg/km
94,0
143,0
209,0
308,0
440,0
572,0
792,0
1155,0
1267,0
1650,0
2134,0
2943,0
3600,0

AWG-No.
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil

core-/sheath-color green-yellow/grey
Part no.
75449
75469
73859
75470
75471
75472
75473
75474
75475
75476
75477
75478
75479

No.cores x
cross-sec.
mm
1G6
1G10
1G16
1G25
1G35
1G50
1G70
1G95
1G120
1G150
1G185
1G240
1G300

Outer
Cop.
approx. mm weight
kg/km
8,5
57,6
9,5
96,0
11,5
154,0
14,0
240,0
15,0
336,0
17,5
480,0
20,0
672,0
22,0
912,0
23,5
1152,0
26,5
1440,0
29,0
1776,0
31,0
2304,0
35,0
2280,0

Weight
approx.
kg/km
94,0
143,0
209,0
308,0
440,0
572,0
792,0
1155,0
1267,0
1650,0
2134,0
2943,0
3600,0

AWG-No.
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil

Dimensions and specifications may be changed without prior notice.

T5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX 300 high flexible PVC single core, 0,6/1kV for drag chain and free
move application


Technical data

Cable structure

Properties

Special PVC single-core cable with


oil-resistant insulation based on
DINVDE0281 part13 and in accordance
with HD21.13S1
Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage
U0/U 600/1000 V
A.C. test voltage, 50 Hz
3000 V
Insulation resistance
min. 20 MOhm/km
Minimum bending radius
for flexible installation
approx. 7,5 cable

Bare copper, extra fine wire conductor to


DINVDE0295 cl.6 and IEC60228 cl.6
Oil-resistant special PVC insulation
Colour see table, or as desired
If this cable is to be double-insulated, then
its external diameter and weight must be
adapted.
Caution with existing cables.


PVC self-extinguishing and flame retardant,


test method B according to VDE0472
part804 and IEC60332-1
Chemical resistance see table Technical
Information

Application
Thanks to their outstanding alternating bending stress characteristics, these cables are ideally suited for use in drag chains, and also for use
in handling devices, robots, and nearly any area requiring flexible used and free motion. Due to its resistance to mineral oils these cables
are well suited for use in mechanical engineering, tool making, and systems engineering, and in steel mills and rolling mills in particularly
critical areas.
Suitable for installation in dry, damp and wet environments. With the black sheath, can also be used outdoors.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


TOPFLEX 300 black


Part no.
79623
79624
79625
79626
75431
75432
75433
70519
75434
73714
75435
75436
72872
75437

No.cores x
cross-sec.
mm
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240

Outer
Cop.
approx. mm weight
kg/km
4,2
24,0
5,1
38,4
6,0
57,6
7,4
96,0
8,8
154,0
10,7
240,0
12,1
336,0
14,0
480,0
16,3
672,0
18,3
912,0
20,0
1152,0
23,0
1440,0
24,8
1776,0
28,7
2304,0

Weight
approx.
kg/km
42,0
58,0
85,0
130,0
210,0
300,0
420,0
580,0
780,0
1010,0
1200,0
1600,0
2030,0
2600,0

AWG-No.
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil

79631
79632
79633
79634
78106
78107
78108
70518
78109
78110
78111

Part no.
79627
79628
79629
79630
75438
75439
75440
70536
75441
75442
73885
75443
75444
75445

No.cores x
cross-sec.
mm
1G2,5
1G4
1G6
1G10
1G16
1G25
1G35
1G50
1G70
1G95
1G120
1G150
1G185
1G240

Outer
Cop.
approx. mm weight
kg/km
4,2
24,0
5,1
38,4
6,0
57,6
7,4
96,0
8,8
154,0
10,7
240,0
12,1
336,0
14,0
480,0
16,3
672,0
18,3
912,0
20,0
1152,0
23,0
1440,0
24,8
1776,0
28,7
2304,0

Weight
approx.
kg/km
42,0
58,0
85,0
130,0
210,0
300,0
420,0
580,0
780,0
1010,0
1200,0
1600,0
2030,0
2600,0

AWG-No.

Outer
Cop.
approx. mm weight
kg/km
4,2
24,0
5,1
38,4
6,0
57,6
7,4
96,0
8,8
154,0
10,7
240,0
12,1
336,0
14,0
480,0
16,3
672,0
18,3
912,0
20,0
1152,0

Weight
approx.
kg/km
42,0
58,0
85,0
130,0
210,0
300,0
420,0
580,0
780,0
1010,0
1200,0

AWG-No.

14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil

TOPFLEX 300 red


Part no.

TOPFLEX 300 green-yellow

No.cores x
cross-sec.
mm
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120

TOPFLEX 300 blue


Outer
Cop.
approx. mm weight
kg/km
4,2
24,0
5,1
38,4
6,0
57,6
7,4
96,0
8,8
154,0
10,7
240,0
12,1
336,0
14,0
480,0
16,3
672,0
18,3
912,0
20,0
1152,0

Weight
approx.
kg/km
42,0
58,0
85,0
130,0
210,0
300,0
420,0
580,0
780,0
1010,0
1200,0

AWG-No.
14
12
10
8
6
4
2
1
2/0
3/0
4/0

Part no.
79635
79636
79637
79638
78112
78113
78114
78115
78116
78117
73884

No.cores x
cross-sec.
mm
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120

14
12
10
8
6
4
2
1
2/0
3/0
4/0

Dimensions and specifications may be changed without prior notice.

T6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX 1002 flexible double insulated single core 1000V




Technical data

Cable structure

Special PVC single-core cable with double


insulation approved to ULAWM Style1032
Temperature range
flexing -5 C to +90 C
fixed installation -40 C to +90 C
Nominal voltage
acc. to VDE U0/U 600/1000 V
acc. to UL 1000 V
A.C. test voltage, 50 Hz
4000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
for flexible installation
approx. 7,5x cable
for fixed installation
approx. 3x cable

Properties

Bare copper conductor, fine wire stranded


1st insulation: special PVC, black colour
2nd insulation: special PVC
Sheath colour black

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)

Application
PVC single-core cable suitable for medium mechanical stresses with free movement without tensile stress or forced movements in dry,
moist and wet rooms, and in open air (fixed installation).
Must not be installed directly in the ground or water.
This two-approvals single-core cable is preferred for use in export-oriented mechanical engineering, in machine tools, production lines and
systems engineering.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
701377
701378
701379
700160
701380
700159

No.cores x
cross-sec.
mm
1x1,5
1x2,5
1x4
1x6
1x10
1x16

AWG-No. Outer
approx.
mm
16
4,5
14
5,0
12
6,1
10
7,2
8
9,0
6
10,2

Cop.
weight
kg/km
14,4
24,0
38,4
57,6
96,0
154,0

Weight
approx.
kg/km
30,0
49,0
75,0
118,0
180,0
250,0


Part no.
701381
701382
701383
701384
701387
701388

No.cores x
cross-sec.
mm
1x25
1x35
1x50
1x70
1x95
1x120

AWG-No. Outer
approx.
mm
4
11,6
2
13,0
1
16,0
2/0
17,1
3/0
19,5
4/0
22,3

Cop.
weight
kg/km
240,0
336,0
480,0
672,0
912,0
1152,0

Weight
approx.
kg/km
370,0
490,0
665,0
910,0
1195,0
1545,0

Dimensions and specifications may be changed without prior notice.

T7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX 302 / 302-UL very high flexible PVC single core double
insulated 0,6/1kV


Technical data

Cable structure

Properties

TOPFLEX 302
Special PVC single-core cable with double
insulation flexible at low temperatures
Temperature range
flexing -15 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 600/1000 V
A.C. test voltage, 50 Hz
3000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
for flexible installation
approx. 5x cable diameters
TOPFLEX 302-UL
Technical data as above, but
with additional UL Approval Style 10107
Nominal voltage UL 1000 V

Bare copper, extra fine wire conductor to


DINVDE0295 cl.6 and IEC60228 cl.6
PVC insulation flexible at low temperatures,
natural colour
PVC sheath compound TM2 flexible at low
temperatures
Sheath colour black, UV-resistant


Sheath UV-resistant
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Chemical resistance see table Technical
Information
The cable is permissible for overvoltage
category II

Application
These cables are specially designed for use as connecting cables on sliding contacts for current collectors, and also for use in energy supply
chains, automatic handling devices, robots, machine tools, machining and processing equipment, and nearly any area requiring flexible used
and free motion.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


TOPFLEX 302 without UL-approval


Part no.
72946
73924
72950
72945
75450
72947
75451
75452
75453
72944
75454
75455
75456
75457
75458

No.cores x
cross-sec.
mm
1x1,5
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240

Outer
Cop.
approx. mm weight
kg/km
4,0
14,4
4,5
24,0
5,6
38,4
6,1
57,6
8,0
96,0
9,8
153,6
11,8
240,0
12,9
336,0
14,6
480,0
17,5
672,0
20,2
912,0
21,6
1152,0
23,5
1440,0
25,7
1776,0
29,5
2304,0

Weight
approx.
kg/km
25,0
42,0
58,0
85,0
130,0
190,0
280,0
400,0
520,0
720,0
1050,0
1220,0
1500,0
1940,0
2675,0

AWG-No.
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil

TOPFLEX 302 with UL-approval


Part no.
700231
700232
700233
700234
701351
700114
701352
701353
701354
700235
701355
701356
701357
701358
701359

No.cores x
cross-sec.
mm
1x1,5
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240

AWG-No. Outer
approx.
mm
16
5,2
14
6,4
12
7,0
10
7,5
8
9,1
6
10,8
4
13,1
2
14,1
1
15,8
2/0
19,0
3/0
21,5
4/0
23,2
300 kcmil
25,2
350 kcmil
27,0
500 kcmil
31,5

Cop.
weight
kg/km
14,4
24,0
38,4
57,6
96,0
153,6
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0
1776,0
2304,0

Weight
approx.
kg/km
25,0
42,0
58,0
85,0
130,0
190,0
280,0
400,0
520,0
720,0
1050,0
1220,0
1500,0
1940,0
2675,0

Dimensions and specifications may be changed without prior notice.

T8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX 301 / 301-C unscreened(double insulated)/


screened high flexible PUR single core 0,6/1kV for drag chain application


Technical data

Cable structure

Properties

TOPFLEX 301 (unscreened)


Special PUR single-core cable acc. to
ULAWM Style10553
Temperature range
flexing -15 C to +80 C
Nominal voltage
acc. to VDE U0/U 600/1000 V
acc. to UL 1000 V
A.C. test voltage 3000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
approx. 7,5 cable
TOPFLEX 301C (screened)
Tech. data as per TOPFLEX 301
Coupling resistance
max. 250 Ohm/km

TOPFLEX 301 (unscreened)


Bare copper, extra fine wire conductor to
DINVDE0295 cl.6 and IEC60228 cl.6
PVC core insulation flexible at low
temperatures, grey
PUR sheath
Colour black or green-yellow
TOPFLEX 301C (screened)
Structure as per TOPFLEX 301, but
additionally
Fleece wrapping between screen and
sheath
Tinned copper braided screening, approx.
85% coverage
Sheath colour black


PUR outer sheath: low adhesion, flame


retardant, extremely abrasion resistant,
resistant to UV, oil, hydrolysis and microbial
attack
Optimised insulation materials ensure
resistance to oils (including mineral oils),
greases, coolants, hydraulic fluids as well
as many alkalis and solvents
The optimised external diameter and the
reduced weight facilitate use in multi-shift
operation with extreme alternating
bending stress cycles
Thanks to its excellent mechanical
characteristics, the wear-resistant,
notch-resistant, flame-retardant PUR
sheath provides high functional reliability
over long periods

Application
TOPFLEX 301 (unscreened)
These cables are specially designed for use in energy supply chains, automated handling equipment, robots, machine tools, processing and
manufacturing machinery.
TOPFLEX 301C (screened)
Applications as described above, additionally optimal compliance with electromagnetic compatibility (EMC) requirements on account of the
approx. 85% coverage by the braided screening.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


TOPFLEX 301 double insulated, black unscreened


Part no.
75375
75376
75377
75378
75379
75380
75381
75382
75383
75384
75385
75386

No.cores x
cross-sec.
mm
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240

Outer
Cop.
approx. mm weight
kg/km
7,1
58,0
8,8
96,0
10,5
154,0
11,2
240,0
13,5
336,0
15,8
480,0
18,0
672,0
20,4
912,0
22,2
1152,0
25,0
1440,0
28,0
1776,0
32,5
2304,0

Weight
approx.
kg/km
85,0
130,0
190,0
280,0
400,0
520,0
720,0
1050,0
1220,0
1500,0
1940,0
2645,0

AWG-No.
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil

TOPFLEX 301C black screened EMC


Part no.
75399
75400
75401
75402
75403
75404
75405
75406
75407
75408
75409
75410

No.cores x
cross-sec.
mm
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240

Outer
Cop.
approx. mm weight
kg/km
7,8
95,0
9,5
124,0
10,8
186,0
12,2
278,0
13,7
384,0
15,4
530,0
17,6
753,0
21,7
1006,0
22,4
1257,0
24,3
1562,0
26,5
1895,0
30,3
2704,0

Weight
approx.
kg/km
144,0
170,0
220,0
340,0
460,0
580,0
820,0
1200,0
1350,0
1680,0
2100,0
3100,0

AWG-No.
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil

TOPFLEX 301 double insulated, green-yellow unscreened


Part no.
75387
75388
75389
75390
75391
75392
75393
75394
75395
75396
75397
75398

No.cores x
cross-sec.
mm
1G6
1G10
1G16
1G25
1G35
1G50
1G70
1G95
1G120
1G150
1G185
1G240

Outer
Cop.
approx. mm weight
kg/km
7,1
58,0
8,8
96,0
10,5
154,0
11,2
240,0
13,5
336,0
15,8
480,0
18,0
672,0
20,4
912,0
22,2
1152,0
25,0
1440,0
28,0
1776,0
32,5
2304,0

Weight
approx.
kg/km
85,0
130,0
190,0
280,0
400,0
520,0
720,0
1050,0
1220,0
1500,0
1940,0
2645,0

AWG-No.
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil

Dimensions and specifications may be changed without prior notice.

T9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

TOPFLEX 304 / 304-C unscreened(double insulated)/


screened high flexible PVC single core 0,6/1kV for drag chain application


Technical data

Cable structure

Properties

Special PVC single-core cable


Temperature range
flexing -5 C to +80 C
fixed installation -40 C to +80 C
Nominal voltage U0/U 600/1000 V
A.c. test voltage, 50 Hz
3000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
for flexible installation
approx. 5x cable

TOPFLEX 304
Bare copper, extra fine wire conductor to
DINVDE0295 cl.6 and IEC60228 cl.6
PVC insulation, green-yellow
PVC sheath compound TM2
Sheath colour grey
TOPFLEX 304C
Construction as above, but
Tinned copper braid, coverage approx. 85%


PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Chemical resistance see table Technical
Information

Application
Thanks to their outstanding alternating bending stress characteristics, these cables are ideally suited for use in drag chains, and also for use
in handling devices, robots, and nearly any area requiring flexible used and free motion.
TOPFLEX 304C
Optimum compliance with requirements for electromagnetic compatibility (EMC) by approx. 85% coverage from the braided screen.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


TOPFLEX 304
Part no.
79639
79640
79641
71544
79642
79643
79644
79645
79646
79647
79648
79649
79650
79651
79652

No.cores x
cross-sec.
mm
1G2,5
1G4
1G6
1G10
1G16
1G25
1G35
1G50
1G70
1G95
1G120
1G150
1G185
1G240
1G300

Outer
Cop.
approx. mm weight
kg/km
4,5
24,0
5,6
38,4
6,1
57,6
8,0
96,0
9,8
154,0
11,8
240,0
12,9
336,0
14,6
480,0
17,5
672,0
20,0
912,0
21,6
1152,0
23,5
1440,0
25,7
1776,0
29,5
2304,0
32,5
2880,0

Weight
approx.
kg/km
42,0
58,0
85,0
130,0
190,0
280,0
400,0
520,0
720,0
1050,0
1220,0
1500,0
1940,0
2675,0
3300,0

AWG-No.
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil

TOPFLEX 304C
Part no.
79653
79654
79655
79656
79657
79658
79659
79660
79661
79662
79685
79663
79664
79665
79666

No.cores x
cross-sec.
mm
1G2,5
1G4
1G6
1G10
1G16
1G25
1G35
1G50
1G70
1G95
1G120
1G150
1G185
1G240
1G300

Outer
Cop.
approx. mm weight
kg/km
5,9
40,0
6,5
50,0
8,3
88,0
8,7
124,0
10,3
190,0
12,4
260,0
13,7
405,0
15,4
560,0
17,5
780,0
21,0
1030,0
22,4
1311,0
24,3
1527,0
26,5
1940,0
30,3
2530,0
35,0
3050,0

Weight
approx.
kg/km
55,0
75,0
125,0
170,0
300,0
420,0
620,0
825,0
1090,0
1395,0
1770,0
1930,0
2635,0
3380,0
3500,0

AWG-No.
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil

Dimensions and specifications may be changed without prior notice.

T 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

GALVANICABLE high-current cable, high flexible and halogen-free




Technical data

Cable structure

Properties

Temperature range
flexing -40 C to +80 C
fixed installation -50 C to +80 C
Operating voltage
U0/U 600/1000 V
Test voltage
3500 V
Insulation resistance
min. 20 MOhm/km
Minimum bending radius
approx. 15x cable

Bare copper, ultra-fine wire conductors


acc. to DINVDE0295 cl.6 and IEC60228
cl.6
Extremely thick PUR wearing sheath
Natural colour, smooth, glossy


PUR wearing sheath: extremely abrasion


resistant, halogen-free, resistant to UV, oil,
hydrolysis and microbial attack
Chemical resistance:
PUR demonstrates significantly better
chemical resistance when compared with
other materials, e.g. rubber or PVC
The extremely thick PUR sheath means
longer service life

Application
This cable is employed as a highly-flexible high-current cathode cable for electroplating drum systems and as a wearing cable in the chemical
industry.
Special feature:
Despite the extremely thick wearing sheath, the highly flexible conductor enables good contact when installing the pear push. Good flexibility
is likewise ensured when the pear push comes into contact with the parts to be electroplated.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
700768
75497
75498
75499

No.cores x
cross-sec.
mm
1x35
1x50
1x70
1x95

Outer
Cop.
approx. mm weight
kg/km
17,2
336,0
19,0
480,0
21,5
672,0
24,0
912,0

Weight
approx.
kg/km
548,0
686,0
950,0
1386,0

AWG-No.
2
1
2/0
3/0


Part no.
74749
700769
700770
700771

No.cores x
cross-sec.
mm
1x120
1x150
1x185
1x240

Outer
Cop.
approx. mm weight
kg/km
27,0
1152,0
28,0
1440,0
30,5
1776,0
36,0
2304,0

Weight
approx.
kg/km
1520,0
2002,0
2610,0
3820,0

AWG-No.
4/0
300 kcmil
350 kcmil
500 kcmil

Dimensions and specifications may be changed without prior notice.

T 11
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Flugzeugheber-T
BAULIFTKABEL B101 / B102 / B103
Photo: HELUKABEL

Trailing Cables
Trailing cables are used for high mechanical
stress, especially for applications with frequent
winding and unwinding with simultaneous
tensile and torsional stress.

Trailing cables are frequently used in building


machinery, conveyors and lifting systems, and
cranes.

T 12
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Flugzeugheber-T trailing, PUR




Technical data

Cable structure

Properties

Temperature range
flexing -20 C to +80 C
Nominal voltage
control cores 300/500 V
power supply cores 0,6/1 kV
A.C. test voltage, 50 Hz
control cores 1500 V
power supply cores 4000 V
Minimum bending radius
for flexible installation
approx. 15x cable

Part no. 70736


Bare copper, extra fine wire conductor to
DINVDE0295 cl.6 and IEC60228 cl.6
Polyethylene core insulation DIN
47100/0.34 mm
Core insulation: special PVC, flexible at low
temperatures, black with number 6-20/0,75
mm and number 1-5/4 mm
0,34 mm cores stranded in pairs and
screened with doubled copper braid
Inner sheath of special PVC flexible at low
temperatures
Cores stranded with elements
Inner sheath of special PVC flexible at low
temperatures over cores
PUR outer sheath with embedded support
braiding
Sheath colour grey RAL 7001
Part no. 77548
Bare copper, extra fine wire conductor to
DINVDE0295 cl.6 and IEC60228 cl.6
Core insulation TPE-E, black with number
+gnye/1 mm and 2,5 mm
Polypropylene core insulation, colour code
DIN 47100/0,34 mm
0,34 mm cores stranded in a pair
Pairs screened with aluminium-coated
polyester foil and tinned copper braiding
Cores and pairs stranded
PUR outer sheath with embedded support
braiding
Sheath colour orange RAL 2003


PUR outer sheath: low adhesion, flame


retardant, extremely abrasion resistant,
halogen-free, resistant to UV, oil, hydrolysis
and microbial attack
PUR-jacket flame retardant according to
DINVDE0482 part265-2-1/ EN50265-2-1/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)

Application
This hybrid cable is designed for the aircraft industry, and contains cores for power supply, control cores, and cores for a positioning laser.
The cable is used to control and position a support robot, which absorbs loads at specific points when loading extremely heavy items, for
example during loading of aircraft assemblies in large transport aircraft of the Airbus industry. The cable is trailing, UV and weather-resistant,
and is provided with an extremely wear-resistant and petrol-resistant special sheath.
Part no. 77548
is designed for similar applications, as a load-reducing lifter in aircraft assembly.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.cores x


cross-sec.
mm
70736
5 x 4 + 5 x 3G0,75 + 2 x 2 x 0,34

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
25,6
390,0
600,0

AWG-No.
12


Part no. No.cores x
Outer Cop.
Weight
cross-sec.
approx. weight approx.
mm
mm
kg/km kg/km
77548
5 x 2,5 + 18G1,0 + 4 x 2 x 0,34 27,0
461,0
750,0

AWG-No.
14

Dimensions and specifications may be changed without prior notice.

T 13
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

BAULIFTKABEL B101 / B102 / B103 to be used at plant elevators




Technical data

Cable structure

Properties

Temperature range
flexing -10 C to +80 C
Nominal voltage
control cores 300/500 V
power supply cores 0,6/1 kV
A.c. test voltage, 50 Hz
control cores 1500 V
power supply cores 3000 V
Minimum bending radius
approx. 10x cable diameters

Bare copper wire, highly flexible


Core insulation of plastic, flexible at low
temperatures, with number and gnye
Sheath of special plastic, flexible at low
temperatures, black
Optional separate copper screening of the
control cores


Sheath UV-resistant
In carriage version with special support
braiding and with PUR sheath particularly
resistant to wear, oil, hydrolysis and
microbial attack

Application
These hybrid cables are used for power supply and control of vertical lifts in the construction industry. There are 3 cable versions.
B101: Here the cable is drawn vertically from a drum as a drag cable via the load platform. The load platform pulls the cable along as it moves
up. During the downwards motion the cable returns to the drum automatically. Our special versions are used at heights of up to about
150 m.
B102: For greater heights, a so-called carriage version is employed, in which the cable is fed at the centre of the tower, i.e. half the way up.
B103: Here the cable is guided via a spring-loaded drum.
These vertical construction lifts are used during new construction and renovation work on high buildings. The rack lattice elements are
fastened at intervals to the exterior facade.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


BAULIFTKABEL B101
Part no. No.cores x
cross-sec.
mm
73519
5 x 2,5 + 10G1,0
73913
5 x 2,5 + 11G1,0
70402
3 x 4 + 7G1,0
70931
4 x 6 + 9G1,0
70377
4 x 6 + 10G1,0
71901
4 x 6 + 15G1,0
71369
4 x 10 + 10G1,0
78123
4 x 16 + 6G1,0
78124
4 x 16 + 10G1,0
78125
4 x 16 + 15G1,0
73726
4 x 16 + 1G2,5 + 4 x 1,0

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
20,0
220,0
306,0
20,0
225,6
320,0
17,4
184,0
360,0
20,5
330,0
555,0
21,0
340,0
575,0
22,0
388,0
625,0
25,0
480,0
870,0
26,1
700,0
1250,0
29,0
710,0
1300,0
31,5
760,0
1380,0
28,5
830,0
1460,0

AWG-No.
14
12
10
10
10
8
6
6
6
6

BAULIFTKABEL B102
Part no. No.cores x
cross-sec.
mm
74293
4 x 16 + 1G2,5 + 2 x 2 x 1,0
74670
4 x 16 + 1G2,5 + 2 x 2 x 1,0
74297
4 x 25 + 1G2,5 + 2 x 2 x 1,0
78122
4 x 35 + 4G2,5 + 2 x 2 x 1,0 + 1
x 1,0

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
28,5
830,0
1080,0
28,5
787,0
1080,0
33,4
1176,0
1500,0
38,0
1500,0
1850,0

AWG-No.

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
13,0
125,0
230,0
15,3
125,0
280,0

AWG-No.

6
6
4
2

BAULIFTKABEL B103
Part no. No.cores x
cross-sec.
mm
77532
4 x 2,5 + 3G1,0
77538
4 x 2,5 + 3G1,0

14
14

Dimensions and specifications may be changed without prior notice.

T 14
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Cables & Wires for


Renewable Energies

T 15
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SOLARFLEX-X PV1-F
SOLARFLEX-X PV1-F Twin
Photo: HELUKABEL

Cables for
Photovoltaic Installations
T

T 16
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description

Page

SOLARFLEX-X PV1-F ...................................................................................................................................................................

T 18

SOLARFLEX-X PV1-F TWIN ..............................................................................................................................................................

T 19

T 17
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SOLARFLEX-X PV1-F


Technical data

Temperature range
-40 C to +90 C
Max.Temp. at conductor +120 C
Nominal voltage
According to VDE 600/1000 V AC
1800 V DC conductor/conductor
AC test voltage
10000 V
Minimum bending radius
fixed installation approx. 4 x outer
diameters
flexing 10 x cable diameter

Cable structure

Properties

Bare copper, tinned, finely stranded


according to DIN VDE 0295 class 5 and IEC
60228 cl. 5
Double-insulated
Insulation cross-linked Polyolefin
Outer sheath cross-linked Polyolefin
Sheath colour black, red or blue
Approvals
According to PV1-F requirement profile for
PV cable DKE/VDE AK 411.2.3
VDE (Reg. 8266)
TV (2 PfG 1169/08.2007, R60025298)
RoHS and CE compliant
UL certification in progress (UL Subject
4703)

Ozone resistant acc. to EN 50396


Weather und UV resistant acc. to HD 605/A1
Halogen-free acc. to EN 50267-2-1, EN
60684-2
Resistant to acid and bases acc. to EN
60811-2-1
Flame-resistant acc. to VDE 0482-332-1-2,
DIN EN 60332-1-2, IEC 60332-1
Very robust and abraison-resistant sheath
acc. to DIN EN 53516
Resistant to short-circuits up to 200 C
thanks to their double insulation;
short-circuits temperature 200 C / 5sec.
Anticipated service life - 25 years
Hydrolysis and ammoniac resistant


Note

Not for direct installation in ground 


Version with rodent protection available:
Solarflex-X PV1-F NTS (V2A braiding)
All types with metre marking


Application
The SOLARFLEX-X PV1-F is used for cabling solar modules.



Part no.
704225
705892
705891
704226
705776
705775
704227
705778
705777
704228
705894
705893
704229
706840
706839
704230
704231
704232
704233
704234
705738
705739
706288
706289

No.cores x
cross-sec.
mm
1x2,5
1x2,5
1x2,5
1x4
1x4
1x4
1x6
1x6
1x6
1x10
1x10
1x10
1x16
1x16
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240

Jacket
colour
black
blue
red
black
blue
red
black
blue
red
black
blue
red
black
blue
red
black
black
black
black
black
black
black
black
black

Outer
approx. mm
4,5
4,5
4,5
5,2
5,2
5,2
5,9
5,9
5,9
6,9
6,9
6,9
8,3
8,3
8,3
10,0
11,0
13,0
15,3
17,0
19,1
22,7
25,5
28,3

Cop.
weight
kg/km
24,0
24,0
24,0
38,4
38,5
38,4
57,6
57,6
57,6
96,0
96,0
96,0
153,6
153,6
153,6
240,0
336,0
480,0
672,0
912,0
1152,0
1440,0
1776,0
2304,0

Weight
approx. kg/km
42,0
42,0
42,0
60,0
60,0
60,0
82,0
82,0
82,0
123,0
123,0
123,0
190,0
190,0
190,0
285,0
376,0
530,0
745,0
960,0
1220,0
1550,0
1930,0
2550,0

AWG-No.
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14

Dimensions and specifications may be changed without prior notice.

T 18
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SOLARFLEX-X PV1-F TWIN




Technical data

Cable structure

Properties

Temperature range
-40 C to +90 C
Max. temp. at conductor +120 C
Nominal voltage
According to VDE U0/U 600/1000 V AC
1800 V DC conductor/conductor
AC test voltage
6500 V, 50 Hz, 15 kV DC
Minimum bending radius
Single 1,5 cable diameters
Multiple 10 cable diameters

Bare copper, Class 5, tinned, finely stranded


according to DIN VDE 0295 class 5 and IEC
60228 cl. 5
Double-insulated
Insulation cross-linked special Polyolefin
Outer sheath cross-linked special Polyolefin
Sheath colour: black

Approval: TV 2Pfg 1169/08.2007


UV-, ozone-resistant, weather-resistant
Halogen-free
Abrasion and cut resistant
Relatively flexible
Easy to strip
Flame-resistant according to VDE 0482 Part
332-1-2, IEC 60332-1-2
Resistant to short circuits up to 200 C
thanks to double insulation, short circuit
temperature 200 C/5 sec.
Anticipated service life 25 years


Note

Cross-sections up to 2 x 16 mm are
available on request


Application
The SOLARFLEX-X PV1-F TWINis used for cabling solar modules.


Part no.
707234
707235

No.cores x
cross-sec.
mm
2x2,5
2x4

Outer
Cop.
min. - max. weight
mm
kg/km
5,4 - 11,0
50,0
5,8 - 11,8
80,0

Weight
approx.
kg/km
106,0
142,0

AWG-No.
14
12


Part no.
705769
707236

No.cores x
cross-sec.
mm
2x6
2x10

Outer
Cop.
min. - max. weight
mm
kg/km
6,8 - 13,6
120,0
7,8 - 15,8
200,0

Weight
approx.
kg/km
182,0
254,0

AWG-No.
10
8

Dimensions and specifications may be changed without prior notice.

T 19
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUWIND WK 103w
HELUWIND WK 103k
HELUWIND WK 135-Torsion
HELUWIND WK 137-Torsion
HELUWIND WK 300w-Torsion
HELUWIND WK 305-Torsion
HELUWIND WK H07BN4N4-F WIND-Torison
HELUWIND WK 101 H
HELUWIND WK re warning cable Torsion
HELUWIND WK-NTSCGEWOEU-Torsion
HELUWIND WK DLO 2kV
HELUWIND WK Powerline ALU
HELUWIND Thermex 145
HELUWIND WK (N)A2XH
Photo: HELUKABEL

Cables for Wind Power Stations


T

T 20
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description

Page

Functional view of Wind Power Station ..............................................................................................................................................

T 22

Selection table Cables & Wires ............................................................................................................................................................

T 23

HELUWIND WK 103w-T, WK 103w EMV D-T UV-resistant, UL/CSA-Style 10678/21179 Single-/Multicore.......................................................

T 27

HELUWIND WK 103k-T, WK 103k EMV D-T UV-resistant, UL/CSA-Style 10269/2570 Single-/Multicore, screened/unscreened .............................

T 28

HELUWIND WK 135-T, WK 135 D-EMV T UV-resistant, UL/CSA-Style** 10553 / 20234, Single-/Multicore 90C (80C nach UL), suitable for offshore....

T 29

HELUWIND WK 137-T / WK 137 EMV D-T FT4 UV-resistant, suitable for offshore, UL/CSA-Style 10553/20234, Single-/Multicore, 90C (80C according to UL)

T 30

HELUWIND WK 300w-Torsion 1,8/3kV UV-resistant ...............................................................................................................................

T 31

HELUWIND WK 305-Torsion 1,8/3kV UV-resistant, suitable for offshore .........................................................................................................

T 32

HELUWIND WK H07BN4-F WIND-Torsion Torsion +/- 150/1m, UV-resistant, 750V/ 90C .................................................................................

T 33

HELUWIND WK 101 H 0,6/1kV halogen-free ..............................................................................................................................................

T 34

HELUWIND WK Fire Alarm Cable-Torsion halogen-free, FT1, 24V ..............................................................................................................

T 35

HELUWIND WK NTSCGEWOEU-Torsion 3,6 / 6kV ...................................................................................................................................

T 36

HELUWIND WK DLO 2kV FT4, UV-resistant, UL44 1kV, 90C, VW-1, LS, MSHA ........................................................................................................

T 37

HELUWIND WK Powerline ALU 105C robust 0,6/1kV oder 1,8/3kV ..........................................................................................................

T 38

HELUWIND WK THERMFLEX 145 halogen-free, +145C..............................................................................................................................

T 39

HELUWIND WK (N)A2XH 0,6/1kV halogen-free...........................................................................................................................................

T 40

T 21
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Functional view of Wind Power Station

Rotor blade

Pod

Gearbox
Brake

Generator

Wind-direction tracking

Rotor hub &


blade adjustment

Tower

Cables and wires


for use in:
Pod
Cable loop
Tower
Tower control / transformer
Base of tower

Tower control / transformer

Medium-high voltage level

Base

T 22
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

0,6/
1kV

X (*)

-40 +90 -35 +90

WK 103k-T

10269
cRUus
2570

1000V

0,6/
1kV

-40 +80 -40 +80

WK 103k EMV D-T

10269
cRUus
2570

1000V

0,6/
1kV

-40 +80 -40 +80

WK 135-T

10553
cRUus
20234

60332
-3

1000V

0,6/
1kV

-40 +90 -40 +90

T 29

WK 135 EMV D-T

10553
cRUus
20234

60332
-3

1000V

0,6/
1kV

-40 +90 -40 +90

T 29

WK 137-T FT4

10553
cRUus
20234

Xc


1000V

0,6/
1kV

-40 +90 -40 +90

T 30

WK 137 EMV D-T

10553
cRUus
20234

Xc

1000V

0,6/
1kV

-40 +90 -40 +90

T 30

1,8/
3kV

WK 300w-T

WK 305-T

WK H07BN4-F WIND-T

450/
750V

WK 101 H

0,6/
1kV

WK Fire Alarm Cable-T

24V

WK NTSCGEWOEU-T

WK DLO 2kV

UL 44

WK (N)A2XH

3,6/
6kV

60332
-3

WK Thermex 145

1,8/
3kV

WK Powerline ALU

*in preparation

60332
-3

60332
-3

** in accordance with UL 1277, Table 11.2

0,6/
1kV

T 27

T 28

T 28

-40 +90 -35 +90

-40 +90 -40 +90

T 32

-45 +90 -35 +90

T 33

-50 +100 -40 +90

-50 +90 -40 +80

2000V

T 27

can be found on page

1000V

twistable +/- 90 per meter

twistable +/- 140 per meter

twistable +/- 150 per meter

10678
cRUus
21179

temp. exing to (in C)

WK 103w EMV D-T

temp. exing from (in C)

UV-resistant

-40 +90 -35 +90

temp. non-exing to (in C)

oil resistant I

temp. non-exing from (in C)

oil resistant II**

offshore employment

nominal voltage according to VDE

X (*)

halogen-free

nominal voltage according to UL

0,6/
1kV

re tests FT4

1000V

VDE*

CE
X

CSA

10678
cRUus
21179

Torsion Cables

UL-Style

WK 103w-T

Usage, see chart on page T 22

re tests FT1 (with FT2)

Selection table Cables & Wires

T 31

T 34

+/215

T 35

+/100

-40 +90 -40 +90

-40 +90

T 37

-40 +105 -20 +105

T 38

T 36

0,6/
1kV

-55 +145 -20 +120

T 39

0,6/
1kV

-30 +90

T 40

-5

+50

cfor multi-core types

T 23
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

temp. exing to (in C)


+80

A6

F-CY-JZ

300/
500V

-40

+80

-40

+80

A 27

Y-CY-JZ

300/
500V

-40

+80

-5

+80

A 32

JZ-500 HMH
JZ-500 HMH-C

60332-3

300/
500V

-40

+70

-15

+70

A 62
A 71

60332-3

60332-3

MEGAFLEX 500
MEGAFLEX 500-C

JZ-600
JZ-600-Y-CY
Single 600-J/-O
Single 600-CY -J/-O

JZ-600 HMH
JZ-600 HMH-C

300/
600V

300/
500V

600 V

0,6/
1kV

1kV

JZ-602
JZ-602-CY

600V

JZ-603
JZ-603-CY

600V

300/
500V

600V

450/
750V

60332-3

-40

+80

-30

+90

A 64
A 73

-40

+80

-5

+80

A 16
A 36

-40

+90

-5

+90

N 120
N 121

-40

+70

-15
-5

+70

A 66
A 75

black

-40

+80

-5

+80

N 10
N 20

-40

+90

-5

+90

N7
N 17

-40

+70

-5

+70

N9
N 19

-40

+90

-55

+145

0,6/
1kV

HELUTHERM 145 MULTI


HELUTHERM 145 MULTI-C

0,6/
1kV

JZ-600-UL/CSA
JZ-600-Y-CY-UL/CSA

H07RN-F
H07RN-F/SOOW

0,6/
1kV

300/500V
to 1,0 mm2
450/750V
from 1,5 mm2

can be found on page

temp. exing from (in C)


-15

Cu-Shield

temp. non-exing to (in C)


+80

UV-resistant

-40

oil resistant II

halogen-free

temp. non-exing from (in C)

nominal voltage according to VDE

FT1 equivalent to IEC 60332-1

300/
500V

HAR

CE

CSA

UL-Style

JZ-500

Control Cables

Usage, see chart on page T 22

with VDE Reg.-No.

nominal voltage according to UL

Selection table Cables & Wires

F6
N 80

-35

+120

E5
E 14

T 24
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

DATAFLAMM
DATAFLAMM-C

350/
500V

DATAFLAMM-C-PAAR

350/
500V

LiYY-UL
LiYY-TP-UL

SUPERTRONIC-PUR
SUPERTRONIC-C-PUR

300V

-40

-40

350V

-20

-40

+80

-5

+80

B9
B 11

+70

-5

+70

B8
B 23

+70

-5

+70

B 24

+80

-10

+80

N 65
N 67

+70

-5

+70

C 33
C 34

+80

-40

+80

N 102
N 103

+70

-40

+70

C 35
N 104

can be found on page

temp. non-exing from (in C)

UV-resistant

-40
-30

Cu-Shield

350/
500V

temp. exing to (in C)

temp. exing from (in C)

temp. non-exing to (in C)

TRONIC-CY
PAAR-TRONIC-CY

oil resistant II

halogen-free

nominal voltage according to VDE

nominal voltage according to UL

FT1 equivalent to IEC 60332-1

with VDE Reg.-No.

HAR

CE

CSA

UL-Style

Data Cables

Usage, see chart on page T 22

Selection table Cables & Wires

SUPERTRONIC-330 PUR
SUPERTRONIC-330-C-PUR

300V

300V

SUPER-PAAR-TRONIC-C-PUR
SUPER-PAAR-TRONIC 340-C-PUR

300V

350V

-30
-40

+80
+90

-5

+70

K8
K 16

-40
-55

+90
+145

-5
-35

+90
+120

N 113

-55

+125

-35

+120

K 22
N 118

N 38

-50

-50

Single Conductors
H07 V-K/(H)07 V-K
H05Z-K/H07Z-K
FIVENORM

HELUTHERM 145 600V


HELUTHERM 145 600V UL

TRAYCONTROL 300

FT4

300

-25

+105

-25

+105

TRAYCONTROL 300-C

FT4

300

-25

+105

-25

+105

N 40

TRAYCONTROL
300-C TP

FT4

300

-25

+105

-25

+105

N 44

TRAYCONTROL 500

1277

FT4

1000

-40

+90

-5

+90

TRAYCONTROL 500-C

1277

FT4

1000

-40

+90

-5

+90

JZ-604 TC TRAY CABLE

1277

FT4

600

-25

+90

-5

+90

JZ-604-YCY TC
TRAY CABLE

1277

FT4

600

-25

+90

-5

+90

TC TRAY CABLES UL/CSA

N 27

N 35

N 25

N 34

T 25
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

temp. non-exing to (in C)

temp. exing from (in C)

temp. exing to (in C)

+90

-5

+90

-40

+105

-40

+105

R 94

100V

-20

+80

-20

+80

R 99

600V

100V

-40

+105

-20

+60

R 133

X
_

600V
_

100V
100V

X
X

-40
-40

+70
+70

-5
-5

+60
+60

X
X

R 118

X
X

300V
_

100V
100V

X
X

X
X

X
X

-40
-40

+75
+70

-25
-5

+75
+60

X
X

R 114

X
X

X
X

-40
-40

+90
+90

-40
-40

+90
+90

R 36

60332-1

-30

+70

-20

+70

R 34

Industrial Ethernet
105C

60332-1 300V

100V

Industrial Ethernet
S-FTP TORDIERFLEX

60332-1 300V

BUS Cable HELUWIND


WK CAN BUS 105C

BUS Cable
indoor
Probus SK outdoor

X
_

X
_

X
X

BUS Cable
Torsion
Probus L2 industry

X
_

CMX
_

X
X

HAR

can be found on page

temp. non-exing from (in C)


-40

TRAYCONTROL 600

Cu-Shield

UV-resistant
X

1277

TC TRAY CABLES
UL/CSA

halogen-free

CE

oil resistant II

nominal voltage according to UL

nominal voltage according to VDE

FT1 equivalent to IEC 60332-1

1000

CSA

with VDE Reg.-No.

FT4

UL-Style

Usage, see chart on page T 22

Selection table Cables & Wires

N 30

Communication Cables

AT-V(ZN)Y(ZN)Y
AT-V(ZN)H(ZN)11Y

submitted submitted

Fibre Optic Cable mobile,


trailing A-V(ZN)11Y

FT4
submitted

Fibre Optic Cable mobile


A-V(ZN)Y

FT4

-30

+80

-20

+80

R 35

Fibre Optic Breakoutcable


Industry HCS I-V(ZN)YY

FT4

-30

+85

-20

+85

R 44

-20

+80

-20

+80

R 41

LWL-Breakoutkabel
Industrie HCS I-V(ZN)Y11Y

Plastic-bre Optic cable industry


POF/PE I-V2Y, I-V2Y(ZN)11Y

60332-1

Fibre Optic Indoor/Outdoor Cable


A/I-DQ(ZN)BH

60332-1

-20

+80

-20

+80

R 46

-20

+60

-5

+50

R 14

Fibre Optic Outdoor Cable


A-DQ(ZN)B2Y (central)

-20

+60

-5

+50

R 20

Fibre Optic Outdoor Cable


A-DQ(ZN)B2Y (stranded)

-20

+60

-5

+50

R 22

Fibre Optic Outdoor Cable


A-DQ(ZN)B2Y (stranded, Multi-bre)

-20

+60

-5

+50

R 23

T 26
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUWIND WK 103w-T, WK 103w EMC D-T


UV-resistant, UL/CSA-Style 10678/21179 Single-/Multicore


Technical data

Cable structure

Properties

Temperature range
flexing -35 C up tp +90 C
fixed installation -40 C up tp +90 C
installation -20 C up tp +90 C
Operating temperature at conductor
max. +90 C
Nominal voltage
acc. to VDE U0/U 0,6/1kV
also for 1500V DC capable
acc. to UL 1000V
Test voltage 50 Hz
3000 V
Min. bending radius
flexing 10 x cable diameter
fixed installation 4 x cable diameter
Torsion application
+/-140 per 1 m for unshielded types
+/- 90 per 1 m for shielded types
Approvals
UL/CSA-Style 10678/21179
cRUus*, CE compliant
Flame test
FT1

Special stranded bare copper wires


according to IEC 60228
Special insulation heat-resistant
Core identification black with numbers +
gnye
or colour code DIN 47100
Multicore cores stranded
Tinned copper wrapped at EMV-shielded
types
Sheath Special compound heat-resistant
Sheath colour black

UV-resistant
multi-climate operation
torsion tested
flame-retardant
oil-resistant
recyclable
easy to tailor

Note
Available cross sections, part no. and prices
on request.
Please contact us with your individual
requirements via
fax +49 7150 9209-5135.

Application
The HELUWIND WK series was specifically designed for wind power applications.
We supply the leading wind turbine manufacturers with our cables. No reduction factor for ambient temperature up to +30 C.
= The product conforms to the EC low-voltage directive 2006/95/EG.


Dimensions and specifications may be changed without prior notice.

T 27
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUWIND WK 103k-T, WK 103k EMC D-T


UV-resistant, UL/CSA-Style 10269/2570 Single-/Multicore, screened/unscreened,


Technical data

Temperature range
flexing -40 C up tp +80 C
fixed installation -40 C up tp +80 C
installation -40 C up tp +80 C
Operating temperature at conductor
max. +90 C
Nominal voltage
acc. to VDE U0/U 0,6/1kV
also for 1500V DC capable
acc. to UL 1000V
Test voltage 50 Hz
3000 V
Min. bending radius
flexing 10 x cable diameter
fixed installation 4 x cable diameter
Torsion application
+/-140 per 1 m for unshielded types
+/- 90 per 1 m for shielded types
Approvals
UL-Style 10269/2570
cRUus*, CE compliant
Flame test
FT1

Cable structure

Properties

Special stranded bare copper wires


according to IEC 60228
Special insulation cold flexing
Core identification black with numbers +
gnye
or colour code DIN 47100
Multicore cores stranded
Tinned copper wrapped at EMV-shielded
types
Sheath Special compound heat-resistant
Sheath colour black

UV-resistant
multi-climate operation
torsion tested
flame-retardant
oil-resistant
recyclable
easy to tailor

Note
Available cross sections, part no.
and prices on request.
Please contact us with your individual
requirements via
fax +49 7150 9209-5135.

Application
The HELUWIND WK series was specifically designed for wind power applications.
We supply the leading wind turbine manufacturers with our cables. No reduction factor for ambient temperature up to +30 C.
= The product conforms to the EC low-voltage directive 2006/95/EG.


Dimensions and specifications may be changed without prior notice.

T 28
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUWIND WK 135-T, WK 135 D-EMV T


UV-resistant, UL/CSA-Style** 10553 / 20234, Single-/Multicore 90C (80C acc. to UL),
suitable for offshore


Technical data

Temperature range
flexing -40 C up tp +90 C
fixed installation -40 C up tp +90 C
acc. UL up to +80 C
Operating temperature at conductor
max. +90 C
Nominal voltage
acc. to VDE U0/U 0,6/1kV
also for 1500V DC capable
acc. to UL 1000V
Test voltage 50 Hz
3000 V
Min. bending radius
flexing 10 x cable diameter
fixed installation 4 x cable diameter
Torsion application
+/-150 per 1m
Approvals
UL-Style10553/20234
cRUus, CE compliant
Flame test
FT1
IEC 60332-3-24
Halogen free
IEC 60754-1
Smoke density
IEC 61034-1+2

Cable structure

Properties

Special stranded bare copper wires


according to IEC 60228
Special insulation
Core identification black with numbers +
gnye
or colour code DIN 47100
Multicore cores stranded
Tinned copper wrapped at EMV-shielded
types
Sheath Special compound heat-resistant
Sheath colour black

halogen-free
Extrem abrasion resistant
high flame-retardant
torsion testet
suitable for Offshroe
extremely oil resistant
UV resistant
recyclable
Multi climate operation
CCV non-adhesive

Note
The listed part numbers show only a small list
of our production range. All types can be
produced as Single- or Multicore, screened
or unscreened versions. Please contact us
with your individual requirements via
fax +497150 9209-5135.

Application
The HELUWIND WK series was specifically designed for wind power applications.
We supply the leading wind turbine manufacturers with our cables. No reduction factor for ambient temperature up to +50 C.
= The product conforms to the EC low-voltage directive 2006/95/EG.
Advantages of WK135-T over H07BN4-F:
Burning behavior as per FT1 and IEC 60332-3-24
increased wear-resistance
Recyclable


Dimensions and specifications may be changed without prior notice.

T 29
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUWIND WK 137-T / WK 137 EMV D-TFT4


UV-resistant, suitable for offshore, UL/CSA-Style 10553/20234, Single-/Multicore, 90C,
(80C according to UL)


Technical data

Temperature range
flexing -40 C up tp +90 C
fixed installation -40 C up tp +90 C
acc. UL up to +80 C
Operating temperature at conductor
max. +90 C
Nominal voltage
acc. to VDE U0/U 0,6/1kV
also for 1500V DC capable
acc. to UL 1000V
Test voltage 50 Hz
3000 V
Min. bending radius
flexing 10 x cable diameter
fixed installation 4 x cable diameter
Torsion application
+/-150 per 1m
Approvals
UL-Style10553/20234
cRUus, CE compliant
Flame test
FT4
IEC 60332-3-24
Halogen free
IEC 60754-1
Smoke density
IEC 61034-1+2

Cable structure

Properties

Special stranded bare copper wires


according to IEC 60228
Special insulation
Core identification black with numbers +
gnye
or colour code DIN 47100
Multicore cores stranded
Tinned copper wrapped at EMV-shielded
types
Sheath Special compound heat-resistant
Sheath colour black

halogen-free
Extrem abrasion resistant
high flame-retardant
torsion testet
suitable for Offshroe
extremely oil resistant
UV resistant
recyclable
Multi climate operation
CCV non-adhesive

Note
Available cross sections, part no. and
prices on request.
Please contact us with your
individual requirements via
fax +49 7150 9209-5135.

Application
The HELUWIND WK series was specifically designed for wind power applications.
We supply the leading wind turbine manufacturers with our cables. No reduction factor for ambient temperature up to +30 C.
= The product conforms to the EC low-voltage directive 2006/95/EG.
Advantages of WK137-T over H07BN4-F:
Burning behaviorCSA FT4 + IEC 60332-3-24
increased wear-resistance
Recyclable


Dimensions and specifications may be changed without prior notice.

T 30
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUWIND WK 300w-Torsion 1,8/3kV UV-resistant




Technical data

Cable structure

Properties

Temperatur range
flexing -35 C to +90 C
fixed instal. -40 C to +90 C
assemgly -20 C to +90 C
Operating temperature
max. +90 C
Nominal voltage
according VDE U0/U 1,8/3kV
Test voltage 50 Hz
9000 V
Min. bending radius
flexing 10 x Leitungsdurchmesser
fixed instal. 5 x Leitungsdurchmesser
Torsion application
+/-90 per 1m

Special stranded bare copper wires


according to IEC 60228
Special insulation
Core identification black
Sheath Special compound
Sheath colour black

UV resistant
Multi climate operation
torsion testet
flame retardant
oil resistant
recyclable
easy to tailor

Note
Available cross sections, part no. and
prices on request.
Please contact us with your
individual requirements via
fax +49 7150 9209-5135.

Application
The HELUWIND WK series was specifically designed for wind power applications.
We supply the leading wind turbine manufacturers with our cables.
No reduction factor for ambient temperature up to +30 C.
= The product conforms to the EC low-voltage directive 73/23EWG bzw. 93/68EWG.


Dimensions and specifications may be changed without prior notice.

T 31
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUWIND WK 305-Torsion 1,8/3kV UV-resistant, suitable


for offshore


Technical data

Temperature range
flexing -35 C up tp +90 C
fixed installation -40 C up tp +90 C
Operating temperature at conductor
max. +90 C
Nominal voltage
U0/U 1,8/3kV
Test voltage 50 Hz
9000 V
Min. bending radius
flexing 10 x cable diameter
fixed installation5 x cable diameter
Flame retardant
IEC 60332
Halogen free
IEC 60754-1
Smoke density
IEC 61034-1+2
Torsion application
+/-150 per 1m

Cable structure

Properties

Special stranded bare copper wires


according to IEC 60228
Special insulation
Core identification black
Sheath Special compound
Sheath colour black

halogen free
extremely abrasion resistant
Offshore suitable
UV resistant
Multi climate operation
torsion testet
flame retardant
oil resistant
recyclable
easy to tailor

Note
Available cross sections, part no. and prices
on request.
Please contact us with your individual
requirements via
fax +49 7150 9209-5135.

Application
The HELUWIND WK series was specifically designed for wind power applications.
We supply the leading wind turbine manufacturers with our cables. No reduction factor for ambient temperature up to +50 C.
= The product conforms to the EC low-voltage directive 73/23EWG bzw. 93/68EWG.


Dimensions and specifications may be changed without prior notice.

T 32
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUWIND WK H07BN4-F WIND-Torsion


Torsion +/- 150/1m, UV-resistant, 750V/90C


Technical data

Cable structure

Properties

Temperature range:
Ambient temperature at least -45 C
+90 C at the conductor
Nominal voltage:
450/750V
Test voltage:
3000V
Min. bending radius:
6 x cable diameter
Torsion application:
+/-150 per 1m
Approvals:
CE conformed

Special bare stranded copper wire, as IEC


60228
Special EPR insulation black
Special EPR Sheath compound
Sheath colour black

UV-resistant


Note

Available cross sections, part no. and prices


on request.
Please contact us with your individual
requirements via
fax +4971509209-5135.

Application
The HELUWIND WK series was specifically designed for wind power applications.
We supply the leading wind turbine manufacturers with our cables.
= The product conforms to the EC low-voltage directive 2006/95/EG.
Dimensions and specifications may be changed without prior notice.

T 33
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUWIND WK 101 H 0,6/1kV halogen-free




Technical data

Cable structure

Properties

Temperature range:
flexing -40 C to +9 0 C
fixed installation acc. to UL -40 C to
+90 C
assembly -40 C to +90 C
Operation temperature on conductor
max. +90 C
Nominal voltage:
according to VDE U0/U 0.6/1kV,
according to UL 1000V
Test voltage 50 Hz:
3000 V
Min. bending radius:
10 x cable diameter
Torsion application:
WK135-Torsion up to +/-150 per 1m
Approvals:
UL-style** 10553 singlecore types
UL-style** 20234 multicore types
cRUus, CE conformed
Flame test:
FT4* in preparation

Special bare stranded copper wire, as. per


DIN VDE 0295
Special conductor insulation
Conductor colours, black with numbers +
gnye
Cores cabled together by multicore types
() = Screened version optional (EMC)
Special SSH jacket compound, non-adhesive
colour: black

UV-resistant
oil-resistant in accordance with UL 1277,
Table 11.2 oil resistant II
non-adhesive
high flame-retardant
halogen-free
Multi climate operation
Torsion elastic (WK 135-T)
Extrem abrasion-proof sheath
Sea water resistant
recyclable


Note

Available cross sections, part no.


and prices on request.
Please contact us with your
individual requirements via
fax +49 7150 9209-5135.

Application
The HELUWIND WK 125 and WK 135-Torsion series of cables were specifically designed for use in wind turbines.
We supply the leading wind turbines manufacturers with our cables.
Advantages of WK 125 and 135-T over H07BN4-F:
Burning behavior as per FT4 and IEC 60332-3-24
increased wear-resistance. Recyclable
= The product conforms to the EC low-voltage directive 2006/95/EG


Dimensions and specifications may be changed without prior notice.

T 34
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUWIND WK Fire Alarm Cable-Torsion


halogen-free, FT1, 24V


Technical data

Temperature range:
flexing -40 C to +80 C
fixed installation -50 C to +90 C
Nominal voltage:
24V
Test voltage:
Conductor/conductor 1500V
conductor/shield 800V
Minimum bending radius:
10 x cable diameter
Torsion application:
3 x 360 on 5m
Approvals:
IEC 60332-1, test type B acc. to VDE 0472
Part 804,
CE-conformed
Flame test:
FT1

Cable structure

Properties

Special stranded bare copper wires


according to IEC 60228 cl. 6
Special Polyester insulation
Core identification black with numbers 1_
cores stranded
tinned copper helically wound for EMC
screening
Sheath PUR
Sheath colour red RAL 3000

very good oil and petrol-resistance acc. to


DIN VDE 0250 and 0472
very resistant to acids, alkali and solvents
extremely abrasion resistant
halogen free


Note

Available cross sections, part no. and prices


on request.
Please contact us with your individual
requirements via
fax +4971509209-5135.

Application
The HELUWIND WK series was specifically designed for wind power applications.
We supply the leading wind turbine manufacturers with our cables.
= The product conforms to the EC low-voltage directive 2006/95/EG.


Dimensions and specifications may be changed without prior notice.

T 35
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUWIND WK-NTSCGEWOEU-Torsion 3,6 / 6kV




Technical data

Cable structure

Properties

Temperature range
flexingmin. -40 C
+90 C atconductor
Nominal voltage
U0/U 1,8/3kV
Test voltage
10kV
Torsion application
+/-100 per 1m free hanging
Approvals
acc. to DIN VDE 0250-813
CE compliant
Minimum bending radius
\ GEFPI HMEQIXIV

Special stranded tinned copper wires


according to IEC 60228
Special EPR insulation
Core identification black
conduction layer
MC or CRSheath
Sheathcolour black

for torsion application


UV resistant
Ozon resistant
Oil resistant

Note
Available cross sections, part no. and prices
on request.
Please contact us with your individual
requirements via
fax+4971509209-5135.

Application
The HELUWIND WK series was specifically designed for wind power applications.
We supply the leading wind turbine manufacturers with our cables.
= The product conforms to the EC low-voltage directive 2006/95/EG.


Dimensions and specifications may be changed without prior notice.

T 36
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUWIND WK DLO 2kV FT4, UV-resistant, UL44 1kV, 90C, VW-1, LS, MSHA


Technical data

Cable structure

Properties

Temperature range:
flexing -40 C to +90 C
Nominal voltage:
DLO 2000V
Approvals:
UL44, CSA, ICEA S-68-516/NEMA WC-8,
MSHA, VW-1, FOR CT USE. LS CERTIFIED
Flame test:
FT4, FT1

Special tinned stranded copper wire, acc.


to ASTM B-172, ASTM B-33
Special wrapping
Special EPR insulation
Special CPE jacket compound, non-adhesive
Jacket colour: black

UV-resistant


Note

Available cross sections, part no. and prices


on request.
Please contact us with your individual
requirements via
fax+4971509209-5135.

Application
The HELUWIND WK DLO was specifically designed for wind power applications for nominal voltageup tp 2kV.
We supply the leading wind turbine manufacturers with our cables.
= The product conforms to the EC low-voltage directive 2006/95/EG.


Dimensions and specifications may be changed without prior notice.

T 37
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUWIND WK Powerline ALU 105C robust


0,6/1kV or 1,8/3kV


Technical data

Cable structure

Temperature range
flexing -20 C up tp +105 C
fixed installation -40 C up tp +105 C
Nominal voltage
acc. to VDE U0/U 0,6/1kV
or 1,8/3kV
Test voltage 50 Hz
2500 V or 9kV
Min. bending radius
flexing 10 x cable diameter
fixed installation4 x cable diameter
Approvals
in acc. to DIN VDE 0250-813
CE compliant
Flame test
IEC 60332-1

Special stranded bare copper wires


Special insulation heat-resistant
Core identification black
Sheath Special compound heat-resistant
Sheath colour black

Properties

UV resistant
flame retardant
oil resistant
rexycable
easy to tailor

Note
Our WK Powerline robust with the special
shielding ist especially for flexing using or for
heavy conditions.
Pleasse ask for more notes and informations
about the properties and the assembly.
Available cross sections, part no. and prices
on request.
Please contact us with your individual
requirements via
fax +49 7150 9209-5135.

Application
The HELUWIND WK series was specifically designed for wind power applications.
We supply the leading wind turbine manufacturers with our cables.
= The product conforms to the EC low-voltage directive 2006/95/EG.


Dimensions and specifications may be changed without prior notice.

HELUWIND WK Powerline ALU 0,6/1 kV


HELUWIND WK Powerline ALU 1,8/3 kV
HELUWIND WK Powerline ALU robust 0,6/1 kV
HELUWIND WK Powerline ALU robust 1,8/3 kV
HELUWIND WK Powerline ALU robust halogen free 0,6/1 kV

All options in burial design possible.

T 38
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUWIND WK THERMFLEX 145 halogen-free, +145C




Technical data

Cable structure

Properties

Temperature range
flexing -20 C to +120 C
non-flexing -55 C to +145 C
Nominal voltage
U0/U 0,6/1 kV
Test voltage
3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexiing 12,5-15x cable diameter
fixed installation 4x cable diameter
flame retardant
IEC 60332-3-24 Cat. C

Tinned stranded copper wire, acc. toIEC


60228 cl.5
Special insulation, polyolefin-copolymer
halogen-free, flame retardant
Jacket colour black

Halogen-free, no release of corrosive or


toxic gases
Reduced propagation of fire
Minimal smoke generation
Good abrasion-resistance
Goodoil and weathering resistance
Resistant to UV radiation and ozone
Thermal class B
The materials used are silicone and
cadmium-free and free of substances
harmful to paint adhesion


Note

Available cross sections, part no. and prices


on request.
Please contact us with your individual
requirements via
fax+4971509209-5135.

Application
This special cable is used for example as a generator connecting cable in wind-turbines installations.
Other installation uses:
Connection cable for Heating Class B (130 C) installations for motors, transformers, relays, coils, electro-magnets, etc.
Aggregate connections in the automobile industry.
Halogen-free wiring of switchgear and control cabinets
Connections for heating equipment.
Supplies for high power lighting for industry, sports centres and street lighting.
The HELUWIND WK series was specifically designed for wind power applications.
We supply the leading wind turbine manufacturers with our cables.
= The product conforms to the EC low-voltage directive 2006/95/EG.


Dimensions and specifications may be changed without prior notice.

T 39
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUWIND WK (N)A2XH 0,6/1kV, halogen-free




Technical data

Temperature range
fixed installation -40 C to +90 C
during assembly -5 C to +50 C
max. +90 C at conductor
Nominal voltage
Uo/U 0,6/1kV
also for 1500V DC capable
Test voltage 50 Hz
4kV
Approvals
acc. to VDE
CE compliant
Min. bending radius
15 x cable diameter
Flame test
acc. to DIN VDE 0482 part 266-2, BS 4066,
part 3 / EN 50266-2 /
IEC 60332-3-24 (acc.DIN VDE 0472
Teil 804 cat. C)
Smoke density
acc. DIN VDE 0482 part 268, HD 606,
EN 50268-12 / IEC 61034-12,
BS 7622 Teil 12 (acc. DIN VDE 0472 Teil 816)
Corrosivity
acc. VDE 0482 Teil 267 /
DIN EN 50267-2-2 / IEC 60754-2
(acc. DIN VDE 0472 part 813)
Halogen free
acc. DIN VDE 0482 part 267 / EN 50267-2-1 /
IEC 60754-1
(acc. DIN VDE 0472 part 815)

Cable structure

ALU Conductor acc. IEC60228cl.2


Special insulation VPE
Core identification black
Sheath Polymer compoun
Sheathcolour black

Properties
Halogen-free
UV resistant


Note

Available cross sections, part no. and prices


on request.
Please contact us with your individual
requirements via
fax+4971509209-5135.

Application
The HELUWIND WK series was specifically designed for wind power applications.
We supply the leading wind turbine manufacturers with our cables.
= The product conforms to the EC low-voltage directive 2006/95/EG.


Dimensions and specifications may be changed without prior notice.

T 40
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SENSORFLEX
VERTEILERFLEX 2-Approvals
VERTEILERFLEX
SENSORFLEX-H
Photo: HELUKABEL

Sensor actuator and distributor Cables


These cables for decentralised installation and
control technology are used in plug systems,
sensors and actuators.
They constitute an important connecting element between the periphery and the PLC in
production systems.
While previously it was necessary to carry out
timeconsuming wiring of switchgear cabinets

and machines, now eld bus technology has


made it possible to move the periphery interfaces from the switchgear cabinets to the machines and systems. The assembled cables offer
attractive opportunities for reducing costs, not
only in the eld of automation technology, but
also in the entire manufacturing industry.

T 41
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SENSORFLEX sensor actuator cable, PVC, PUR, PVC/PUR




Technical data

Cable structure

Properties

Temperature range
flexing -5 C to +80 C
fixed installation -30 C to +80 C
Peak operating voltage
to 0,25 mm 350 V
from 0,34 mm 500 V
A.c. test voltage, 50 Hz
to 0,25 mm 1200 V
from 0,34 mm 2000 V
Minimum bending radius
Sensorflex PUR
approx. 7,5x cable
Sensorflex PVC/PUR
approx. 7,5x cable
Sensorflex PVC
approx. 15x cable

Sensorflex PVC
Bare copper, fine wire conductors in acc.
with DINVDE0295 cl.5 and/or cl.6 and
IEC60228 cl.5 and cl.6
PVC core insulation, core colours see below
Special PVC sheath
Sensorflex PUR
Bare copper, ultra-fine wire conductors
acc. to DINVDE0295 cl.6 and/or IEC60228
cl.6
PVC core insulation, core colours see below
PUR sheath
Sensorflex PVC/PUR
Construction as above, except
PVC inner sheath, with PUR sheath applied
over it by means of coextrusion


Sensorflex PVC
Extensively oil resistant.
Chemical Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Sensorflex PUR
PUR sheath: low adhesion, extremely
abrasion resistant, resistant to hydrolysis
and microbial attack
Sensorflex PVC/PUR
The cables with the highly flexible stranded
conductor, cl. 6, are suitable for drag chain
applications
These cables are produced to high quality
specifications and conform with a yellow
sheath to the
DESINA-standard
Sheath colour yellow (RAL1021)
according to DESINA


Note

All cables can be delivered with UL/CSA


approval and Cu shield.
Desina: Explanation: see introduction.


Application

For decentralised installation and control technology.


These cables are used in connector systems for sensors and actuators.
In combination with injected circular connectors and installed actuator-sensor boxes, they constitute an important connecting element
between the periphery and the PLC in production systems. The assembled cables offer attractive opportunities for reducing costs, not only
in the field of automation technology, but also in the entire manufacturing industry.
While previously it was necessary to carry out time-consuming wiring of switchgear cabinets and machines, now field bus technology has
made it possible to move the periphery interfaces from the switchgear cabinets to the machines and systems.
Moving the I/O points to the system periphery enables significant reductions in installation costs.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
yellow

orange

grey

76061
76062
76063
76064
76065
76066
76071
76070
73485
73484
78240
76072
73870

76076
76077
76078
76079
76080
76081
76086
76085
76087
76088
78241
76089
76090

73473
73466
73474
73471
76094
76095
73472
76099
73368
72973
73728
73657
73548

Cable structure
No.cores x
Jacket
cross-sec.
material
mm
3x0,25
PVC
3x0,25
PUR
4x0,25
PVC
4x0,25
PUR
5G0,25
PVC
5G0,25
PVC/PUR
3G0,34
PVC/PUR
3x0,34
PVC
4x0,34
PVC
4x0,34
PVC/PUR
5x0,34
PVC
5G0,34
PVC
5G0,34
PVC/PUR

Core colours
brown, blue, black
brown, blue, black
brown, blue, black, white
brown, blue, black, white
brown, blue, black, white, green-yellow
brown, blue, black, white, green-yellow
brown, blue, green-yellow
brown, blue, black
brown, blue, black, white
brown, blue, black, white
brown, blue, black, white, grey
brown, blue, black, white, green-yellow
brown, blue, black, white, green-yellow

Fine
wire

X
X
X

High
Outer
flex ** approx.
mm
X
4,4
X
4,4
X
4,7
X
4,7
X
4,8
X
4,8
X
4,9
X
4,9
5,2
X
5,2
5,9
5,9
X
5,9

Cop.
weight
kg/km
7,2
7,2
9,6
9,6
12,0
12,0
9,8
9,8
13,1
13,1
16,4
16,4
16,4

Weight
approx.
kg/km
22,0
22,0
26,0
26,0
30,0
30,0
30,0
30,0
43,0
43,0
54,0
54,0
54,0

AWG-No.

24
24
24
24
24
24
22
22
22
22
22
22
22

Dimensions and specifications may be changed without prior notice.

T 42
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

VERTEILERFLEX two-approvals sensor actuator and


distributor cables PVC, PUR, PVC/PUR


Technical data

Cable structure

Properties

Special PVC or PUR sheath acc. to


UL Style 2464 for PVC, or
UL Style 20233 for PUR
Temperature range
flexing -5 C to +80 C
fixed installation -30 C to +80 C
Nominal voltage 300/500 V
A.c. test voltage, 50 Hz
to 0,25 mm 1200 V
from 0,34 mm 2000 V
Minimum bending radius
Sensorflex Two approvals PVC
approx. 7,5x cable
Sensorflex Two approvals PUR
approx. 15x cable

PVC cables
Bare copper, fine wire in acc. with
DINVDE0295 cl.5 or IEC60228 cl.5
PVC core insulation, core colours see below
Special PVC
PUR cables
Bare copper, ultra-fine wire conductors
acc. to DINVDE0295 cl.6 and/or IEC60228
cl.6
PVC core insulation
Core colours see below
PUR sheath
Part Nos. 79907, 75642, 79850
Construction like SENSORFLEX
two-approvals, except
with polypropylene core insulation


PVC cables
Extensively oil resistant.
Chemical Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
PUR cables
Low adhesion, extremely abrasion resistant,
resistant to hydrolysis and microbial attack
Special feature
The cables with the highly flexible stranded
conductor, cl. 6, are suitable for drag chain
applications
The types with PVC/PUR sheath material
have a PVC inner sheath, with a PUR sheath
applied over it by means of coextrusion


Note

All additional cross-sections, also with


UL/CSA approval, are available on request.


Application
For decentralised installation and control technology.
These cables are used in connector systems for sensors and actuators.
In combination with injected circular connectors and installed actuator-sensor boxes, they constitute an important connecting element
between the periphery and the PLC in production systems.
The assembled cables offer attractive opportunities for reducing costs, not only in the field of automation technology, but also in the entire
manufacturing industry.
While previously it was necessary to carry out time-consuming wiring of switchgear cabinets and machines, now field bus technology has
made it possible to move the periphery interfaces from the switchgear cabinets to the machines and systems.
Moving the I/O points to the system periphery enables significant reductions in installation costs.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


SENSORFLEX 2-APPROVALS
Part no.

78284
79907
78286
76345
76347
76348
76349
79850
78287
78288
76351
73571
75642

Jacket colour
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Black RAL9005

Cable structure
No.cores x
cross-sec.
mm
3x0,25
4x0,25
6x0,25
3x0,34
4x0,34
5G0,34
5G0,34
5G0,34
5G0,34
3G0,75
3G0,75
3G0,75
3G0,75

Jacket
material

Core colours

PUR
PUR
PVC
PVC
PVC
PVC/PUR
PVC/PUR
PUR
PVC/PUR
PUR
PVC
PVC
PUR

brown, blue, black


brown, blue, black, white
brown, blue, black, white, grey, pink
brown, blue, black
brown, blue, black, white
brown, blue, black, white, green-yellow
brown, blue, black, white, green-yellow
brown, blue, black, white, green-yellow
JZ, black with numbering + greenyellow
JZ, black with numbering + greenyellow
brown, blue, green-yellow
JZ, black with numbering + greenyellow
JZ, black with numbering + greenyellow

Fine
wire

X
X
X

X
X

High
flex **
X
X
X
X
X
X
X
X

Outer
approx.
mm
4,4
4,7
5,2
4,9
5,2
5,9
5,9
5,9
5,9
5,9
6,7
6,7
5,9

Cop.
weight
kg/km
7,2
9,6
14,4
9,8
13,1
16,4
16,4
16,4
16,4
21,6
28,8
21,6
21,6

Weight
approx.
kg/km
18,0
18,0
36,0
30,0
43,0
54,0
54,0
54,0
54,0
58,0
88,0
58,0
58,0

AWG-No.

24
24
24
22
22
22
22
22
22
18
18
18
18

Continuation

T 43
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

VERTEILERFLEX two-approvals sensor actuator and


distributor cables PVC, PUR, PVC/PUR
SENSORFLEX 2-APPROVALS
Part no.

74551
78289
78290
77352
76350
78291
73587

Jacket colour
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Black RAL9005
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001

Cable structure
No.cores x
cross-sec.
mm
4G0,75
4G0,75
2x1
2x1
11G1
2x1,5
3G1,5

Jacket
material

Core colours

PUR
PVC/PUR
PVC
PVC
PVC/PUR
PVC
PVC

JZ, black with numbering + greenyellow


JZ, black with numbering + greenyellow
black with number 1-2
black with number 1-2
black with number 1-8, bn, bu, gn, ye
brown, blue
brown, blue, green-yellow

Jacket
material

Core colours

PVC/PUR

brown, blue, green-yellow, white, green,


yellow, grey
brown, blue, green-yellow, white, green,
yellow, grey, pink, red
white, red-blue, green, wh-green, yellow,
brown-green, gy-pink, brown, blue,
green-yellow
brown, blue, green-yellow, white, green,
yellow, grey, pink, red, black, violet
brown, blue, gnye, gnwh, white, rdbu, green,
whgn, yellow, bngn, grey, whye, pink, yebn,
red
bn, bu, gnye, gnwh, wh, rdbu, gn, whgn, ye,
bngn, gy, whye, pk, yebn, rd, whgy, bk, gybn,
vt

Fine
wire
X
X
X
X
X
X

High
flex **
X

Outer
approx.
mm
6,9
7,0
7,2
7,2
12,0
6,8
6,9

Cop.
weight
kg/km
29,0
29,0
19,2
19,2
105,6
29,0
44,0

Weight
approx.
kg/km
66,0
66,0
56,0
56,0
225,0
75,0
94,0

Outer
approx.
mm
8,7

Cop.
weight
kg/km
35,0

Weight
approx.
kg/km
82,0

AWG-No.

18
18
17
17
17
16
16

Verteilerflex 2-APPROVALS
Part no.

Jacket colour

Cable structure
No.cores x
cross-sec.
mm
4G0,34

76352

Grey RAL 7001

76353

Grey RAL 7001

6G0,34

PVC/PUR

75614

Grey RAL 7001

8G0,34

PUR

76354

Grey RAL 7001

8G0,34

PVC/PUR

76355

Grey RAL 7001

12G0,34

PVC/PUR

76356

Grey RAL 7001

16G0,34

PVC/PUR

Fine
wire

High
flex **
X
X

AWG-No.

22

9,1

42,0

106,0

22

10,0

65,0

143,0

22

9,1

48,0

110,0

22

10,3

61,0

138,0

22

10,5

74,0

170,0

22

Dimensions and specifications may be changed without prior notice.

T 44
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

VERTEILERFLEX for sensor actuator distributor boxes, PVC, PUR or PVC/PUR




Technical data

Cable structure

Properties

Temperature range
flexing -5 C to +80 C
fixed installation -30 C to +80 C
Operating voltage
U0/U 300/500 V
A.c. test voltage, 50 Hz
2000 V
Minimum bending radius
highly flexible approx. 7,5x cable
flexibel approx. 15x cable

PVC cables
Bare copper, fine wire conductors in acc.
with DINVDE0295 cl.5 and/or cl.6 and/or
IEC60228 cl.5 and cl.6
PVC core insulation
Core colours see below
Special PVC sheath
PUR cables
Bare copper, extra fine wire conductor to
DINVDE0295 cl.6 and IEC60228 cl.6
PVC core insulation
Core colours see below
PUR sheath


PVC cables
Extensively oil resistant.
Chemical Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
PUR cables
Low adhesion, extremely abrasion resistant,
resistant to hydrolysis and microbial attack
Special feature
The cables with the highly flexible stranded
conductor, cl. 6, are suitable for drag chain
applications
The types with PVC/PUR sheath material
have a PVC inner sheath, with a PUR sheath
applied over it by means of coextrusion


Note

All cables can be delivered with UL/CSA


approbation and Cu shield.
Further core numbers, cross-sections an
sheath colours available on request.


Application
These cables are used in connector systems for sensors an actuators.
In combination with injected circular connectors and installed actuator-sensor boxes, they constitute an important connecting element
between the periphery and the PLC in production systems.
The assembled cables offer attractive opportunities for reducing costs, not only in the field of automation technology, but also in the entire
manufacturing industry.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
black

grey

76105
76639

76115


Cable structure
No.cores x
cross-sec.
mm
4G0,34
4G0,34

Jacket
material

Core colours

PVC
PVC/PUR

brown, blue, black, white, green-yellow


yellow, white, green, grey, green-yellow, brown,
blue
white, green, yellow, grey, pink, red, brown, blue,
green-yellow
grey. pink, red, black, violet, white, green, yellow,
brown, blue, green-yellow
white, green, yellow, grey, pink, red, black, violet,
blue, brown
white, green, yellow, grey, pink, red, black, violet,
blue, brown
white, green, yellow, grey, pink, red, black, violet,
blue, brown
black with number 1-2+DIN 47100
pink, yebn, red, gypk, white, rdbu, green, whgn,
yellow, bngn, gy, whye
blue with no.1-2 + gnye, gypk, wh, rdbu, gn,
whgy, ye, bngy, whye, pk, yebn, rd, whgy, bk,
gybn, vt
bn, gypk, rdbu, whgn, bngn, whye, yebn, gybn,
bu, wh, gn, ye, gy, pk, rd, bk, vt, gnye
brown, blue, green-yellow, grey-pink, red-blue,
white-green, brown-green, white, green, yellow,
grey
gypk. rdbu, whgn, bngn, whye, yebn, white,
green, yellow, grey, pink, red, brown, blue, gnye
Black, with printing BR1, BR2, BL1, BL, numbers
1-14
gy, bngn, gn, rdbu, gypk, wh, whgn, whgy, bk,
whye, pk, ye, rd, yebn, vt, gybn, gnye, bn, bu
gypk, wh, rdbu, gn, whgn, ye, bngn, gy, whye,
pk, yebn, rd, whgn, bk, vt, bn, bu, gnye

76107

73574

6G0,34

PVC/PUR

72961

73993

8G0,34

PVC/PUR

76109

74729

8x0,34

PVC

76110

72951

8x0,34

PUR

76108

76117

8x0,34

PVC/PUR

71254
76111

76118
76119

11x0,34
12x0,34

PVC
PVC/PUR

77642

16G0,34

PVC/PUR

76112

76120

16G0,34

PVC/PUR

76113

76121

8G0,5

76114

76122

12G0,5

PUR

79921

14x0,5

PVC

PUR

76640

16G0,5

PVC/PUR

74034

76123

16G0,5

PUR

Fine
wire
X

High
Outer
flex ** approx.
mm
5,8
X
8,7

Weight
approx.
kg/km
58,0
82,0

AWG-No.

22
22

9,1

42,0

106,0

22

9,1

48,0

110,0

22

9,1

41,0

107,0

22

9,1

41,0

107,0

22

8,8

36,0

102,0

22

10,0
10,3

65,0
61,0

143,0
138,0

22
22

12,5

89,0

193,0

22

10,5

74,0

170,0

22

9,9

68,0

136,0

20

Cop.
weight
kg/km
18,0
36,0

X
X

10,4

87,0

160,0

20

12,3

125,0

201,0

20

11,6

106,0

183,0

20

11,6

106,0

183,0

20

Dimensions and specifications may be changed without prior notice.

T 45
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SENSORFLEX-H sensor actuator cables, halogen-free, high flexible drag chain


cable, PUR, mantle EVA +125C


Technical data

Cable structure

Properties

Temperature range
Li12Y11Y/Li9Y11Y
flexing -30 C to +80 C
fixed installation -40 C to +80 C
Li4G4G
flexing -25 C to +125 C
fixed installation -40 C to +125 C
Operating voltage
up to 0,25 mm 350 V
0,34 mm and greater 500 V
A.c. test voltage, 50 Hz
up to 0,25 mm 1200 V
0,34 mm and greater 2000 V
Minimum bending radius
Sensorflex-H Li12Y11Y
Approx. 5x cable
Sensorflex-H Li9Y11Y
Approx. 7,5x cable
Sensorflex-H Li4G4G
Approx. 15x cable

Sensorflex-H (Li12Y11Y-HF)
Bare copper, extra-fine wire conductor
according to DINVDE0295 cl.6 and
IEC60228 cl.6
TPE core insulation, core colours see below
PUR sheath
Sensorflex-H (Li9Y11Y-HF)
Bare copper, extra-fine wire conductor
according to DINVDE0295 cl.6 and
IEC60228 cl.6
PP core insulation, core colours see below
PUR sheath
Sensorflex-H (Li4G4G)
Tinned copper, fine wire conductor
according to DINVDE0295 cl.5 and
IEC60228 cl.5
EVA-based compound for core and sheath
Sheath red/brown (approx. RAL8016)


Sensorflex-H (Li12Y11Y-HF)
Sensorflex-H (Li9Y11Y-HF)
PUR sheath, low adhesion, extremely
abrasion resistant, resistant to hydrolysis
and microbial attack
Highly flexible drag chain cable
Sensorflex-H (Li4G4G)
Heat-resistant
Not suitable for use with drag chains

Application
For decentralised installation and control technology.
These cables are used in connector systems for sensors and actuators.
In combination with injected circular connectors and installed actuator-sensor boxes, they constitute an important connecting element
between the periphery and the PLC in production systems.
The assembled cables offer attractive opportunities for reducing costs, not only in the field of automation technology, but also in the entire
manufacturing industry.
While previously it was necessary to carry out time-consuming wiring of switchgear cabinets and machines, now field bus technology has
made it possible to move the periphery interfaces from the switchgear cabinets to the machines and systems.
Moving the I/O points to the system periphery enables significant reductions in installation costs.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


SENSORFLEX-H (Li12Y11Y) high flexible drag chain cable, PUR


Part no.
black

grey

76283
76284
76285
76286
76287
76288
76289
76290
78265
76291
78267
76292
76293
76294

76299
76300
76301
76302
76303
76304
76305
76306
78266
76307
78268
76308
76309
76310

Cable structure
No.cores x
cross-sec.
mm
2x0,25
3x0,25
4x0,25
5x0,25
2x0,34
3x0,34
4x0,34
5x0,34
5G0,34
2x0,5
3G0,5
3x0,5
4x0,5
5x0,5

Jacket
material

Core colours

PUR
PUR
PUR
PUR
PUR
PUR
PUR
PUR
PUR
PUR
PUR
PUR
PUR
PUR

brown, blue
brown, blue, black
brown, blue, black, white
brown, blue, black, white, grey
brown, blue
brown, blue, black
brown, blue, black, white
brown, blue, black, white, grey
brown, blue, black, white, green-yellow
brown, blue
JZ, black with numbering + greenyellow
brown, blue, black
brown, blue, black, white
brown, blue, black, white, grey

Fine
wire

High
Outer
flex ** approx.
mm
X
4,4
X
4,4
X
4,7
X
4,8
X
4,9
X
4,9
X
5,2
X
5,9
X
5,9
X
5,0
X
5,7
X
5,0
X
5,5
X
6,0

Cop.
weight
kg/km
4,8
7,2
9,6
12,0
6,5
9,8
13,1
16,4
16,4
9,6
14,4
14,4
19,2
24,0

Weight
approx.
kg/km
22,0
22,0
26,0
30,0
30,0
30,0
43,0
54,0
54,0
40,0
43,0
40,0
47,0
55,0

AWG-No.

24
24
24
24
22
22
22
22
22
20
20
20
20
20

Continuation

T 46
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SENSORFLEX-H sensor actuator cables, halogen-free, high flexible drag chain


cable, PUR, mantle EVA +125C
SENSORFLEX-H (Li12Y11Y) high flexible drag chain cable, PUR
Part no.
black

grey

76295
78269
76296
78271
76297
78273
76298

76311
78270
76312
78272
76313
78274
76314

Cable structure
No.cores x
cross-sec.
mm
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75

Jacket
material

Core colours

PUR
PUR
PUR
PUR
PUR
PUR
PUR

brown, blue
brown, blue, green-yellow
brown, blue, black
brown, blue, black, green-yellow
brown, blue, black, white
JZ, black with numbering + greenyellow
brown, blue, black, white, grey

Fine
wire

High
Outer
flex ** approx.
mm
X
5,7
X
5,9
X
5,9
X
6,2
X
6,0
X
7,0
X
7,0

Cop.
weight
kg/km
14,4
21,6
21,6
28,8
28,8
36,0
36,0

Weight
approx.
kg/km
47,0
54,0
54,0
67,0
66,0
80,0
80,0

AWG-No.

18
18
18
18
18
18
18

SENSORFLEX-H (Li9Y11Y) high flexible drag chain cable, PUR


Part no.

75801
77468
76705
77427
77428
78275
77429

Jacket colour
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001
Grey RAL 7001

Cable structure
No.cores x
cross-sec.
mm
3x0,25
4x0,25
8x0,25
4x0,34
3G0,75
3x0,75
4G0,75

Jacket
material

Core colours

PUR
PUR
PUR
PUR
PUR
PUR
PUR

brown, blue, black


brown, blue, black, white
DIN 47100
brown, blue, black, white
JZ, black with numbering + greenyellow
JZ, black with numbering + greenyellow
JZ, black with numbering + greenyellow

Fine
wire

High
flex **
X
X
X
X
X
X
X

Outer
approx.
mm
4,5
4,7
6,0
4,9
6,2
6,2
6,2

Cop.
weight
kg/km
7,2
9,6
19,2
13,1
21,6
21,6
28,8

Weight
approx.
kg/km
22,0
26,0
49,0
43,0
54,0
54,0
66,0

Outer
approx.
mm
7,0

Cop.
weight
kg/km
28,8

Weight
approx.
kg/km
65,0

AWG-No.

24
24
24
22
18
18
18

SENSORFLEX-H (Li4G4G) unqualified for drag chain cable, sheath EVA


Part no.

78359
73575

Jacket colour
Red-brown RAL
8016
Red-brown RAL
8016

Cable structure
No.cores x
cross-sec.
mm
4G0,75
3G1

Jacket
material

Core colours

Fine
wire

EVA

brown, blue, black, green-yellow

EVA

brown, blue, green-yellow

High
flex **

7,0

29,0

60,0

AWG-No.

18
17

Dimensions and specifications may be changed without prior notice.

T 47
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

AIRPORT 400 Hz
Photo: HELUKABEL

Cables for airport 400 Hz


Special cable for drum reeling purpose meeting
the highest mechanical stresses. Mobile cable
in exible feeds in 400 Hz units, especially as
aircraft feeder line on airports.
The qualied employees of our special cable
department will give individual advice and
assistance to develop and construct your cable.

Your personal advice is important to us in order


that we can offer you the right cable for your
purpose. Depending on the cable type these
special cables can be offered with a minimum
length of 100 m, with short delivery periods.

T 48
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

AIRPORT 400 Hz trailing, PUR, halogen-free, flame retardant




Technical data

Cable structure

Properties

Temperature range
-40 C to +90 C
Nominal voltage
115/200 V
Operating voltage
U0/U 0,6/1 kV
Test voltage
4000 V
Bending radius
flexing 7x cable
fixed installation 4x cable

Fine copper wire in acc. with DINVDE0295


and IEC60228
Core insulation TPE, black
with number 1-6 + blue/...,
with number 7-30/1 mm
4 cores each 1 mm twisted to a quad
Cores and 6 bundles laid-up together
PUR inner sheath
Support braiding
PUR outer sheath, orange (RAL 2003)
Part No. 75992
Bare copper conductor, 7 strands
Core insulation cross-linked polyethylene,
black with number 1-6 + gnye
Polyethylene inner sheath
Concentric conductor of plain Cu wires,
cross-section 35 mm
Black polyehtylene outer sheath


Low adhesion, abrasion resistant,


halogen-free, resistant to UV-, oil-,
hydrolysis and microbial attack
Special feature:
The use of four-core cables to transmit large
amounts of power in a 400 Hz grid results in
voltage asymmetries and larger inductive
voltage losses. These unfavourable cable
characteristics can be improved through the
employment of seven-core cables. In this
case the central core is used as a protective
or earth conductor (green/yellow or blue)
and six cores with the same cross-section
(black with imprint) stranded in a single layer
around the central core. Each pair of two
opposite cores is connected in parallel to a
phase conductor.


Note

Distribution only over authorised partner

Application
400 Hz cables are used to supply power to aircraft (on-board power), data processing systems, radar stations, radio stations, etc. For safety
reasons, 400 Hz cables are used to connect data processing systems, radar systems and communications systems to uninterruptible power
supplies. Such power supplies prevent a total failure of power and compensate for frequency and voltage fluctuations. Suitable for installation
indoors, outdoors.
Applications:
Below floor level cable dispensers (drums), attached to jetways and retractable articulated cable carries.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.cores x


cross-sec.
mm
700573 7 x 25 + 6 x 4x1,0
770009 7 x 35 + 6 x 4x1,0
700574 7 x 50 + 6 x 4x1,0

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
41,0
1910,0
2140,0
45,5
2625,0
2950,0
51,0
3590,0
4030,0

AWG-No.
4
2
1


Part no. No.cores x
cross-sec.
mm
75992
7G35

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
35,8
2746,0
3050,0

AWG-No.
2

Dimensions and specifications may be changed without prior notice.

T 49
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

AIRPORT 400 Hz trailing, PUR, halogen-free, flame retardant




Technical data

Cable structure

Properties

Temperature range
-40 C to +90 C
Nominal voltage
115/200 V
Operating voltage
U0/U 0,6/1 kV
Test voltage
4000 V
Bending radius
approx. 6x cable

Part Nos. 700566-700569


Fine copper wire in acc. with DINVDE0295
and IEC60228
Special plastic core insulation
Sheath colour yellow (RAL1021)
Part Nos. 700570, 770001-770003
Fine copper wire in acc. with DINVDE0295
and IEC60228
Core insulation TPE, grey with number
1-4/1 mm
Core 1 mm stranded with bundle
conductor
Double-sheath TPE/PUR
Sheath colour yellow (RAL1021)
Part Nos. 700571, 770005, 770004,
700572
Each set of 4 parts, 700570,
770001-770003, is stranded


Part Nos. 700570, 770001-770003


Low adhesion, abrasion resistant,
halogen-free, resistant to UV-, oil-,
hydrolysis and microbial attack


Note

Distribution only over authorised partner

Application
400 Hz cables are used to supply power to aircraft (on-board power), data processing systems, radar stations, radio stations, etc. For safety
reasons, 400 Hz cables are used to connect data processing systems, radar systems and communications systems to uninterruptible power
supplies. Such power supplies prevent a total failure of power and compensate for frequency and voltage fluctuations. Suitable for installation
indoors, outdoors. Highly flexible, and can thus be plugged directly into the connector in the aircraft without an adapter, and without
endangering the contacts.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
700566 1 x 35
700570 1 x 35 + 4 x 1,0
770001 1 x 50 + 4 x 1,0
700567 1 x 50
700568 1 x 70
770002 1 x 70 + 4 x 1,0
770003 1 x 120 + 4 x 1,0
700569 1 x 120

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
11,5
336,0
430,0
14,0
375,0
490,0
17,0
519,0
600,0
12,6
480,0
665,0
14,0
672,0
910,0
18,7
711,0
800,0
25,0
1191,0
1400,0
23,0
1152,0
1545,0

AWG-No.
2
2
1
1
2/0
2/0
4/0
4/0


Part no. No.cores x
cross-sec.
mm
700571 4 x 1 x 35 + 4 x 1,0
770005 4 x 1 x 50 + 4 x 1,0
770004 4 x 1 x 70 + 4 x 1,0
700572 4 x 1 x 120 + 4 x 1,0

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
33,0
1498,0
2600,0
40,0
2074,0
3900,0
50,0
2844,0
4300,0
56,0
4765,0
7400,0

AWG-No.
2
1
2/0
4/0

Dimensions and specifications may be changed without prior notice.

T 50
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTRUCK 270
HELUTRUCK 271
HELUTRUCK 272 / 273
Photo: HELUKABEL

Truck Cables
These low-voltage cables are designed for
the wiring of electrical installations in the
manufacture of commercial vehicles.

T 51
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTRUCK 270 with ADR-approval, PVC low voltage cable for commercial
vehicles


Technical data

Cable structure

Properties

Temperature range
-40 C to +85 C
Test voltage
2000 V min. 5 minutes
Capacitance
max. 50 pF/m for the data pair
max. 100 pF/m between data pair cores
and the other cores
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
approx.12x cable

Bare copper, fine wire in acc. with


DINVDE0295 cl.5 or IEC60228 cl.5
Cold-resistant special PVC core insulation
Core coding:
up to 9 cores by colour,
10 cores and above white with numbers
(see below)
Special PVC sheath
Colour black


Cold-resistant special PVC sheath,


UV-resistant
Largely resistant to oil, weather, and
chemicals;
Chemical resistance see table Technical
Information
PVC self-extinguishing and flame retardant,
test methodB according to VDE0472
part804 and IEC60332-1
These cables conform to the national
standard ISO4141 and the
international standard DIN/ISO6722
Component codes T.EGG.073-03
Special feature:
Complies with GGVS regulations
Approved and tested by the TV technical
inspectorate

Application
These low-voltage cables are designed for the wiring of electrical installations in the manufacture of commercial vehicles.
Especially suitable for trailers and semitrailers.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
700016 2 x 0,5
700575 2 x 0,75 + 2 x 1,5
700582 7 x 0,75
75255
2x1
75254
2x1
75256
3x1
700578 3 x 1
75257
4x1
75260
5 x 1 + 1 x 2,5
75258
5x1
700580 5 x 1 + 1 x 2,5
75259
5 x 1 + 1 x 2,5
700581 5 x 1 + 1 x 2,5
700576 2 x 1,5

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
4,8
9,6
40,0
7,0
43,2
91,0
7,3
50,4
101,0
6,0
19,2
56,0
6,0
19,2
56,0
6,3
28,8
66,0
6,6
28,8
66,0
6,8
38,4
80,0
9,0
72,0
132,0
7,5
48,0
98,0
9,0
72,0
132,0
9,0
72,0
132,0
9,0
72,0
132,0
6,6
28,8
66,0

AWG-No.
20
18
18
17
17
17
17
17
17
17
17
17
17
16


Part no. No.cores x
cross-sec.
mm
700577 2 x 1,5
700579 4 x 1,5
75262
6 x 1,5 + 1 x 2,5
700032 7 x 1,5
75261
7 x 1,5
75263
8 x 1,5 + 1 x 2,5
700583 8 x 1,5 + 5 x 2,5
75267
9 x 1,5 + 4 x 2,5
75265
10 x 1,5 + 3 x 2,5
75319
10 x 1,5 + 3 x 2,5 + 2 x 1,5
700017 10 x 1,5 + 3 x 2,5 + 2 x 1,5
75266
10 x 1,5 + 3 x 2,5
700018 11 x 1,5 + 3 x 2,5
700142 3 x 2,5 + 4 x 1,5

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
6,6
28,8
66,0
7,5
57,6
106,0
10,3
110,5
187,0
10,3
100,8
185,0
8,9
100,2
165,0
11,7
139,2
238,0
14,8
235,2
360,0
14,8
200,0
350,0
14,4
215,0
366,0
14,4
244,8
393,0
14,3
244,8
391,0
13,0
216,0
345,0
13,5
230,4
365,0
10,3
129,6
221,0

AWG-No.
16
16
16
16
16
16
16
16
16
16
16
16
16
14

Dimensions and specifications may be changed without prior notice.

T 52
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTRUCK 271 with ADR-approval, PUR low voltage cable for commercial
vehicles


Technical data

Cable structure

Properties

Temperature range
-40 C to +85 C
Test voltage
2000 V min. 5 minutes
Capacitance
max. 50 pF/m for the data pair
max. 100 pF/m between data pair
cores and the other cores
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
approx. 12x cable

Bare copper, fine wire in acc. with


DINVDE0295 cl.5 or IEC60228 cl.5
Cold-resistant special PVC core insulation
Core coding:
up to 9 cores by colour,
10 cores and above white with numbers
(see below)
Inner sheath from special PVC
PUR outer sheath
Colour black
Also available with PVC sheath


PUR outer sheath, low adhesion, abrasion


resistant, halogen-free, resistant to UV-,
oil-, hydrolysis and microbial attack
These cables conform to the national
standard ISO4141 and the
international standard DIN/ISO6722
Component codes T.EGG.074-03
Special feature:
Complies with GGVS regulations
Approved and tested by the TV technical
inspectorate
PUR sheath provides high resistance to
abrasion, UV and wear

Application
These low-voltage cables are designed for the wiring of electrical installations in the manufacture of commercial vehicles. Especially suitable
for trailers and semitrailers manufactured for the transport of GGVS hazardous substances.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.cores x


cross-sec.
mm
75528
2x1
700585 2 x 0,75 + 2 x 1,5
75529
2x1
700586 2 x 1,5
700587 2 x 1,5
75932
2 x 4 + 3 x 1,5 + 2 x 1,5
75541
2 x 6 + 3 x 1,5 + 2 x 1,5
75540
2 x 6 + 3 x 1,5
75530
3x1
700588 3 x 1
75531
4x1
700589 4 x 1,5
75532
5x1

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
6,0
19,0
56,0
7,0
43,2
91,0
6,0
19,0
56,0
6,6
28,8
67,0
6,6
28,8
67,0
12,0
148,8
230,0
12,0
187,2
320,0
12,0
158,6
270,0
6,3
28,8
66,0
6,3
28,8
66,0
6,8
38,5
80,0
7,5
57,6
105,0
7,5
48,1
98,0

AWG-No.
17
18
17
16
16
12
10
10
17
17
17
16
17


Part no. No.cores x
cross-sec.
mm
700591 5 x 1 + 1 x 0,25
75533
5 x 1 + 1 x 2,5
700590 5 x 1 + 1 x 2,5
75534
5 x 1 + 1 x 2,5
75536
6 x 1,5 + 1 x 2,5
700592 7 x 0,75
75535
7 x 1,5
75537
8 x 1,5 + 1 x 2,5
75539
10 x 1,5 + 3 x 2,5
700594 10 x 1,5 + 3 x 2,5
75538
10 x 1,5 + 3 x 2,5 + 2 x 1,5
700595 18 x 1,5
700596 25 x 1,5

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
9,0
72,0
132,0
9,0
72,0
132,0
9,0
72,0
132,0
9,0
72,0
132,0
10,3
110,4
187,0
7,9
50,4
100,0
8,9
100,8
165,0
11,7
139,2
238,0
14,4
214,0
366,0
14,4
214,0
366,0
14,4
244,8
393,0
17,0
259,2
520,0
19,9
360,0
730,0

AWG-No.
17
17
17
17
16
18
16
16
16
16
16
16
16

Dimensions and specifications may be changed without prior notice.

T 53
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUTRUCK 272 / 273 Flat cable for the sideways lighting with
GGVS-authorization, Battery cable, battery charging cable


Technical data

Cable structure

Properties

HELUTRUCK 272
Temperature range
-40 C to +85 C
Test voltage
2000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
fixed installation 5x cable
HELUTRUCK 273
Temperature range
-40 C to +85 C
Nominal voltage
75 V DC
Test voltage
3000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
fixed installation 15x cable

HELUTRUCK 272
Bare copper wire conductors in acc. with
DINVDE0295 cl.5 or IEC60228 cl.5
Special PVC core insulation, cold-resistant
Core colours white, brown (Part No.76706),
white, black (Part No.78983, 700035)
Cold-resistant special PVC sheath
Colour black
HELUTRUCK 273
Bare copper, fine wire in acc. with
DINVDE0295 cl.5 or IEC60228 cl.5
Special PVC core insulation, cold-resistant
Core colours red and black
Cold-resistant special PVC sheath
Colour black
Also available with PUR sheath


UV-resistant, largely resistant to oil,


weather, and chemicals, self-extinguishing
and flame retardant, test method B
according to VDE0472 part804 and
IEC60332-1
Chemical resistance see table Technical
Information
HELUTRUCK 272
Polarity easy to determine by a white line
on the sheath above the white core
HELUTRUCK 273
Complies with GGVS regulations
Approved and tested by the TV technical
inspectorate
The additional sheath means that the cable
is very robust, and can be installed without
a corrugated conduit
Installation time is shorter due to twin
design
Polarity is easy to determine even without
stripping thanks to an imprint with the type
designation and on the sheath over the
positive core. This helps prevent wrong
connections
The special construction of the conductor
enables optimal crimping
Easy mechanical separation of the sheath
web

Application
HELUTRUCK 272
This low-voltage cable is designed for the wiring of electrical installations in the manufacture of commercial vehicles. Especially suitable for
trailers and semitrailers. This flat cable can be used for simple and quick contacting of sidelights by means of core penetration. Its flat
construction and the special contacting method eliminate the need for time-consuming assembly of cables. This facilitates quick installation,
making it possible to save a great deal of time.
HELUTRUCK 273
This battery cable can be used between the battery and the ultimate consumer (e.g. DC motor of the tail-lift).
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


HELUTRUCK 272
Part no.
76706
78983
700035

No.cores x
cross-sec.
mm
2x1,5
2x1,5
2x1,5

Outer
Cop.
approx. mm weight
kg/km
6,8
28,8
6,8
28,8
6,8
28,8

Weight
approx.
kg/km
90,0
90,0
90,0

AWG-No.
16
16
16

HELUTRUCK 273
Part no.
75507
75508
75509
75510
75511
75512
75513
75514
75515

No.cores x
cross-sec.
mm
2x2,5
2x4
2x6
2x10
2x16
2x25
2x35
2x50
2x70

Outer
Cop.
approx. mm weight
kg/km
9,4
48,0
11,5
77,0
15,2
116,0
18,8
192,0
21,0
308,0
25,6
480,0
28,0
672,0
33,0
960,0
36,0
16,8

Weight
approx.
kg/km
87,0
125,0
175,0
270,0
390,0
575,0
820,0
1065,0
1475,0

AWG-No.
14
12
10
8
6
4
2
1
2/0

Dimensions and specifications may be changed without prior notice.

T 54
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Inquiry Special Cable


Please send inquiry to:
MARYLAND METRICS
P.O. Box 261
Owings Mills, MD 21117 USA
ph: (410)358-3130 (800)638-1830
fx: (410)358-3142 (800)872-9329
email: sales@mdmetric.com
web: http://mdmetric.com

Sender

Contact
Phone

Enquiry

Fax

Requirement

No.

Date

once

continuous

yearly requirement approx.

Coil
 Drum

Make-up

Delivery
required

m


m

Size
Type of Cable
Application

a.)
b.)

c.)

Construction
1. Conductor

 indoor  outdoor
 stationary
 for exing
 with reversed bending / torsion
 Drag chain: speed
m/s
Acceleration
m/s2
Tracing range
load  cyclic
 non-cyclic
Temperatures ambient

 Copper
 bare

 St-Cu
 tinned

continuous

 solid
 silvered

No. of cores x cross section


No. of cores x cross section
No. of cores x cross section

intermitted

 Stranded wire (
 nickel-plated 

x
x
x

 PE  Zell-PE
 FEP  PTFE

mm2
mm2
mm2

 PUR


 PETP

m
C for

Min/Std

mm)

No. of wires x diam.


No. of wires x diam.
No. of wires x diam.

 Rubber

x
x
x

mm
mm
mm

2. Insulation

 PVC
 ETFE

 Thermopl. rubber

 Silicone

3. Colourcode

 black with white numbers  with protected conductor green-yellow  colours to DIN 47100  colours to VDE


4. Screening

 Single core
 Pairs
 Cu-bare
 Cu-tinned
as  Braiding
 Serving

which core/pair

 Cu-silvered
 Alu-Foile (St)

Covering approx.
%
Drain wire bare/tinned
mm
Stranded drain wire bare/tinned
mm
with/without protection against elec. shock, hazard under screen, with/without foil/insulation over screen

5. Support
Element

 Hemp

 Polypropylen

 galv. Steel

Tensile load

 Polypropylen

 PVC

mm

6. Centre

 Kevlar

7. Stranding

 Cores in layer stranding

8. Inner sheath

 yes:

 PVC

9. Overall
Screen

 yes:

 Cu-bare
 braiding

 twisted in pair

 Rubber

 Silicone

 all

 Fleece

 Foil

 Cu-tinned
 Serving

 Cu-silvered
 Alu-Foil

with/without drain wire/stranded drain wire


10. Armouring

 Steel wire galv.

11. Outer sheath

 PVC
 Silicon

 PUR
 ETFE

 PETP
 FEP

 PE
 PTFE

Outer

 Rubber

mm

mm /mm2

Covering
bare/tinned

 Thermopl. Rubber

 Neoprene

Colour

 Outerprinting /text)
Operating voltage
Test Voltage

V
V

Capacity Cond./Cond.
Capacity Cond./shield.

pF/m
pF/m

T 55
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Electrical
Characters
Additional
details

Pre-assembled Cables

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Pre-assembled Cables

U1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled Cables
Today, more and more users are installing preassembled and pre-mounted cables and wires.
Many years ago HELUKABEL recognised this trend
and consequently we can offer a complete range
of pre-assembled cables and wires. Other assembly
variations according to your special requirements
are available.
The versatility of possible uses and combinations of
plugs and connection types which we can provide
can offer an economical and easy solution to your
problems. You will benet from our wealth of
experience and from the advantage of an easy
and effective installation.
Questions to connection techniques?
HELUKABEL has the answer.
Phone: +49 7150 9209-0

U2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description

Page

Servo motor, feedback, and fan cables


Base line for use on SIEMENS drive systems
Pre-assembled servo motor cables for xed laying ...................................................................................

U5

Extensions on request

Pre-assembled servo motor cables for mobile use....................................................................................

U6

Extensions on request

Pre-assembled feedback cables for xed laying ............................................................................................

U7

Extensions on request

Pre-assembled feedback cables for mobile use .............................................................................................

U8

Extensions on request

Pre-assembled servo motor cables for xed laying (Drive-Cliq) .................................................................

U9

Extensions on request

Pre-assembled servo motor cables for mobile use (Drive-Cliq) ......................................................................

U 10

Extensions on request

Pre-assembled feedback cables for xed laying (Drive-Cliq)............................................................................

U 11

Extensions on request

Pre-assembled feedback cables for mobile use (Drive-Cliq) ............................................................................

U 12

Extensions on request

Base line for use on REXROTH drive systems


Pre-assembled servo motor cables for mobile use (PVC) .............................................................................

U 13

Links on request

Pre-assembled servo motor cables for mobile use (PUR) .............................................................................

U 14

Links on request

Pre-assembled feedback cables for mobile use (PVC) ......................................................................................

U 16

Links on request

Pre-assembled feedback cables for mobile use (PUR) .....................................................................................

U 17

Links on request

Base line for use on LENZE drive systems


Pre-assembled servo motor cables for xed laying (Global Drive) ............................................................

U 18

Extensions on request

Pre-assembled servo motor cables for mobile use (Global Drive) .................................................................

U 19

Extensions on request

Pre-assembled feedback cables for xed laying (Global Drive) ......................................................................

U 20

Extensions on request

Pre-assembled feedback cables for mobile use (Global Drive) .......................................................................

U 21

Extensions on request

Pre-assembled fan cables for xed laying (Global Drive) .................................................................................

U 22

Extensions on request

Pre-assembled fan cables for mobile use (Global Drive) ...................................................................................

U 23

Extensions on request

Pre-assembled servo motor cables for xed laying (L-Force) ...................................................................

U 24

Extensions on request

Pre-assembled servo motor cables for mobile use (L-Force) ........................................................................

U 25

Extensions on request

Pre-assembled feedback cables for xed laying (L-Force) .............................................................................

U 26

Extensions on request

Pre-assembled feedback cables for mobile use (L-Force) ..............................................................................

U 27

Extensions on request

Pre-assembled fan cables for xed laying (L-Force) .........................................................................................

U 28

Extensions on request

Pre-assembled fan cables for mobile use (L-Force) ..........................................................................................

U 29

Extensions on request

U3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description

Page

Servo motor, feedback, and fan cables


Base line for use on SEW drive systems
Pre-assembled servo motor cables for xed laying .......................................................................................

U 30

Pre-assembled servo motor cables for mobile use........................................................................................

U 31

Pre-assembled feedback cables for xed laying ............................................................................................

U 32

Pre-assembled feedback cables for mobile use .............................................................................................

U 33

Pre-assembled servo motor cables for xed laying .......................................................................................

U 34

Extensions on request

Pre-assembled servo motor cables for mobile use........................................................................................

U 35

Extensions on request

For use on HEIDENHAIN measurement systems/hand wheels


Pre-assembled feedback cables .................................................................................................................................

U 36

Pre-assembled adapter cables....................................................................................................................................

U 37

Upon request we are able to offer you the appropriate changes and
customized assemblies in all lengths.
Of course, you can also get our connectors and cables separately
please see HELUTEC configurator at www.helutec.de

Robot cables
ROBOFLEX-recycle, M12 femal one end pre-assembled 3-, 4- and 5-pin ....................................................................................

U 41

ROBOFLEX-recycle, M12 sensor cable 4-pin + PE one end pre-assembled ..................................................................................

U 43

ROBOFLEX-recycle, M12 both ends pre-assembled ..............................................................................................................

U 44

ROBOFLEX-recycle, M12 5-pin + PE both ends pre-assembled ................................................................................................

U 46

ROBOFLEX-recycle, M12 plug straight or angled, pre-assembled on one end, 3-pin, 4-pin and 5-pin ................................................

U 47

ROBOFLEX-recycle, M8 femal one end pre-assembled ..........................................................................................................

U 48

ROBOFLEX-recycle, M8 pre-assembled on both ends ...........................................................................................................

U 49

ROBOFLEX-recycle, M8 plug, straight or angled, pre-assembled on one side, 3-pin and 4-pin.........................................................

U 51

ROBOFLEX-recycle, M12 sensor cable screened one end pre-assembled ...................................................................................

U 52

ROBOFLEX-recycle, M12 sensor cable screened both ends pre-assembled .................................................................................

U 54

ROBOFLEX-recycle, Twin cables M12 to M12 .......................................................................................................................

U 56

ROBOFLEX-recycle, Twin cables M12 to M12 .......................................................................................................................

U 57

Connecting cables
PVC connecting cables................................................................................................................................................

U 58

Rubber connecting cables ..........................................................................................................................................

U 59

YELLOWFLEX connecting cable meter marking ............................................................................................................

U 60

PUR connecting cables, orange..................................................................................................................................

U 61

Extensions / Supply cables


Extensions / Supply cables, CEE-Extensions / Cold equipment / PVC-Extensions .....................................................................

U 62

Front connecting cables for Simatic S7 ....................................................................................................................

U 63

U4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled servo motor cables


for fixed laying

Base line for use on SIEMENS drive systems




Technical data

Temperature range
moving 0 C to +60 C
not moving -20 C to +80 C
Bending radius
moving 20 x cable diameter
not moving 5 x cable diameter
Max. acceleration
2 m/s2
Bending cycles
100,000 for 20x cable diameter
Nominal voltage
(UL/CSA) 1000 V
(power + signal)
Nominal voltage
(VDE) U0/U 0.6/1kV (power)
24 V (signal)
Test voltage, power cores 4 kV
Test voltage, signal cores 2 kV
Insulation resistance 20 MOhm x km


Cable structure

Power supply cores


Bare copper, according to IEC60228CL.6
PVC core insulation
Core identification U/L1/C/L+
V/L2
W/L3/D/L Earth core KVIIR]IPPS[
Signal cores
Copper conductors, bare
TPE-E core insulation
Core identification black
white
Cores twisted in pairs
Shield, tin-plated copper braiding
Complete shield made of tin-plated
copper braiding
Coverage approx. 80%
PVC outer jacket
Sheath colour, orange (RAL 2003)

Application
This high quality pre-assembled motor
connection cable is specially manufactured
for applications with static installation. The
special PVC outer jacket allows use in many
industrial environments of general machine
and plant construction.


Characteristic

Economical alternatives to the cable carrier


compatible cable types which otherwise meet
all requirements of the servo drive
manufacturers. These pre-assembled cables
can be produced in any lengths and also with
customer-specific modifications.


Note

Please observe the drive or controller


manufacturer's information about maximum
permitted cable length.

Approbations
Desina (ISO 23570)
VDE
UL/CSA


Manufacturer
Designation
6FX5002-5CA01
6FX5002-5CA11
6FX5002-5CA21
6FX5002-5CA31
6FX5002-5CA41
6FX5002-5CA51
6FX5002-5CA61
6FX5002-5CA13
6FX5002-5CA23
6FX5002-5DA01
6FX5002-5DA11

Helukabel
Designation
5CA01 DESINA PVC
5CA11 DESINA PVC
5CA21 DESINA PVC
5CA31 DESINA PVC
5CA41 DESINA PVC
5CA51 DESINA PVC
5CA61 DESINA PVC
5CA13 DESINA PVC
5CA23 DESINA PVC
5DA01 DESINA PVC
5DA11 DESINA PVC

Helukabel
Part no.
660224
660227
660230
660234
660237
660238
660239
660229
660232
660241
660244


Manufacturer
Designation
6FX5002-5DA21
6FX5002-5DA31
6FX5002-5DA41
6FX5002-5DA51
6FX5002-5DA61
6FX5002-5DA13
6FX5002-5DA23
6FX5002-5DA33
6FX5002-5DA43
6FX5002-5DA53

Helukabel
Designation
5DA21 DESINA PVC
5DA31 DESINA PVC
5DA41 DESINA PVC
5DA51 DESINA PVC
5DA61 DESINA PVC
5DA13 DESINA PVC
5DA23 DESINA PVC
5DA33 DESINA PVC
5DA43 DESINA PVC
5DA53 DESINA PVC

Helukabel
Part no.
660247
660250
660254
660257
660259
660666
660249
660252
660255
660667

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled servo motor cables


for mobile use

Base line for use on SIEMENS drive systems




Technical data

Temperature range
moving -20 C to +60 C
not moving -50 C to +80 C
Bending radius
moving 10 x cable diameter
not moving 7 x cable diameter
Max. acceleration
5 m/s2
Bending cycles
10 million for 12x cable diameter
Operating voltage U0/U 600/1000 V (VDE)
1000 V (UL)
Test voltage, power cores 4 kV
Test voltage, control cores 2 kV
Insulation resistance 500 MOhm x km


Approbations

Desina (ISO 23570)


VDE
UL/CSA

Cable structure

Power supply cores


Bare copper, extra fine wire conductor
according to DINVDE0295CL.6
high quality PP core insulation
Core identification U/L1/C/L+
V/L2
W/L3/D/L Earth core KVIIR]IPPS[
Signal cores
Copper conductors, bare
High quality PP core insulation
Core identification black
white
Cores twisted in pairs
Shielding screened with tin-plated copper
wires
Complete shield made of tin-plated
copper braiding
Coverage approx. 80%
PUR outer sheath
Sheath colour, orange (RAL 2003)

Application
This high quality pre-assembled motor
connection cable is specially manufactured
for applications with mobile use. The special
PUR outer jacket allows use in many industrial
environments of general machine and plant
construction.


Characteristic

These pre-assembled cables can be produced


in any lengths and also with
customer-specific modifications.


Note

Please observe the installation instructions


for laying cables in cable carriers on Page 36
and the drive or controller manufacturer's
information about maximum permitted
cable length.


Manufacturer
Designation
6FX8002-5CA01
6FX8002-5CA11
6FX8002-5CA21
6FX8002-5CA31
6FX8002-5CA41
6FX8002-5CA51
6FX8002-5CA61
6FX8002-5CA13
6FX8002-5CA23
6FX8002-5DA01
6FX8002-5DA11

Helukabel
Designation
5CA01 DESINA PUR
5CA11 DESINA PUR
5CA21 DESINA PUR
5CA31 DESINA PUR
5CA41 DESINA PUR
5CA51 DESINA PUR
5CA61 DESINA PUR
5CA13 DESINA PUR
5CA23 DESINA PUR
5DA01 DESINA PUR
5DA11 DESINA PUR

Helukabel
Part no.
660053
660056
660059
660063
660066
660067
660068
660058
660061
660070
660073


Manufacturer
Designation
6FX8002-5DA21
6FX8002-5DA31
6FX8002-5DA41
6FX8002-5DA51
6FX8002-5DA61
6FX8002-5DA13
6FX8002-5DA23
6FX8002-5DA33
6FX8002-5DA43
6FX8002-5DA53

Helukabel
Designation
5DA21 DESINA PUR
5DA31 DESINA PUR
5DA41 DESINA PUR
5DA51 DESINA PUR
5DA61 DESINA PUR
5DA13 DESINA PUR
5DA23 DESINA PUR
5DA33 DESINA PUR
5DA43 DESINA PUR
5DA53 DESINA PUR

Helukabel
Part no.
660076
660080
660084
660088
660089
89800
89802
660082
660085
660668

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled feedback cables


for fixed laying

Base line for use on SIEMENS drive systems




Technical data

Temperature range
-20 C to +80 C
Bending radius
18 x cable diameter
Max. acceleration
2 m/s2
Bending cycles
100,000
Max. operating voltage 30 V AC
Test voltage 500 V
Insulation resistance 100 MOhm x km


Approbations
Desina (ISO 23570)
UL/CSA

Cable structure

Application

Tinned copper conductors


Polyolefin polymer core insulation
Complete shield, tin-plated copper
braiding
Coverage approx. 80%
PVC outer jacket
Sheath colour green
Structure(3x(2x0.14)+4x0.14+2x0.5)
3 pairs with tin-plated copper wires,
coverage approx. 90%
Colour code
Pair 1: yellow + green
Pair 2: black + brown
Pair 3: red + orange
Quad 1: grey + blue + white/yellow +
black/white Pair 4: brown/red +
brown/blue
Structure(3x(2x0.14)+4x0.14+4x0.22+2x0.5)
3 pairs with tin-plated copper wires,
coverage approx. 90%
Colour code
Pair 1: yellow + green
Pair 2: black + brown
Pair 3: red + orange
Quad 1: grey + blue + white/yellow +
black/white Quad 2: brown/yellow +
brown/grey + green/black + red/green
Pair 4: brown/red + brown/blue
Structure(3x2x0.34+4x0.5)
Colour code
Pair 1: brown + violet
Pair 2: brown + black
Pair 3: red + orange
Pair 4: yellow + green
Quad: yellow/white + red/white +
blue/white + black/white


This high quality pre-assembled sensor


connection cable is specially manufactured
for applications with static installation. The
special PVC outer jacket allows use in many
industrial environments of general machine
and plant construction.


Characteristic

Economical alternatives to the cable carrier


compatible cable types which otherwise meet
all requirements of the servo drive
manufacturers. These pre-assembled cables
can be produced in any lengths and also with
customer-specific modifications.


Note

Please observe the drive or controller


manufacturer's information about maximum
permitted cable length.

Manufacturer
Designation
6FX5002-2AD00
6FX5002-2AH00
6FX5002-2CA11
6FX5002-2CA15
6FX5002-2CA31
6FX5002-2CA51
6FX5002-2CA61
6FX5002-2CA72
6FX5002-2CB51

Helukabel
Designation
2AD00 DESINA PVC
2AH00 DESINA PVC
2CA11 DESINA PVC
2CA15 DESINA PVC
2CA31 DESINA PVC
2CA51 DESINA PVC
2CA61 DESINA PVC
2CA72 DESINA PVC
2CB51 DESINA PVC

Helukabel
Part no.
660207
660209
660210
660211
660212
660214
660215
660669
660217


Manufacturer
Designation
6FX5002-2CC11
6FX5002-2CD01
6FX5002-2CF02
6FX5002-2CG00
6FX5002-2CH00
6FX5002-2EQ10
6FX5002-2CE02
6FX5002-2CM00
6FX5002-2CE07

Helukabel
Designation
2CC11 DESINA PVC
2CD01 DESINA PVC
2CF02 DESINA PVC
2CG00 DESINA PVC
2CH00 DESINA PVC
2EQ10 DESINA PVC
2CE02 DESINA PVC
2CM00 DESINA PVC
2CE07 DESINA PVC

Helukabel
Part no.
660670
660671
660219
660672
660220
660222
660673
660674
660675

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled feedback cables


for mobile use

Base line for use on SIEMENS drive systems




Technical data

Temperature range
moving -20 C to +60 C
not moving -50 C to +80 C
Bending radius
moving 11 x cable diameter
not moving 7 x cable diameter
Max. acceleration
5 m/s2
Bending cycles
10 million for 12x cable diameter
Operating voltage 30 V
Test voltage 500 V
Insulation resistance 10 MOhm x km


Approbations

Desina (ISO 23570)


UL/CSA

Cable structure

Application

Tinned copper conductors


high quality PP core insulation
Complete shield, tin-plated copper
braiding
Coverage approx. 80%
PUR outer sheath
Sheath colour orange
Structure/colour code
(2x2x0.18) bl, bn, rd, or
(4x2x0.18) bl+bn, rd+or, ye+gn, bu+vio
(8x2x0.18) bl+bn, rd+or, ye+gn, bu+vio,
gy+wh, wh/bl+wh/bn, wh/rd+wh/or,
wh/ye+wh/gy
(12x0,22) bl, bn, rd, or, ye, gn, bu, vio, gy,
wh, wh/bl, wh/bn
(4x2x0.34+4x0.5) rd+or, ye+gn, bu+vio,
bl+bn, wh/rd, wh/ye, wh/bu, wh/bl
(3x(2x0.14)+2x(0.5)) rd+or, ye+gn, bl+bn,
bl, rd
(3x(2x0.14)+2x0.5+4x0.14) rd+or, ye+gn,
bl+bn, bn/rd, bn/bu, gy, bu, wh/ye, wh/bl
(3x(2x0.14)+2x0.5+4x0.14+4x0.22)
rd+or, ye+gn, bl+bn, bn/rd, bn/bu, gy, bu,
wh/ye, wh/bl, bn/ye, bn/gy/gn/bl, gn/rd

This high quality pre-assembled sensor


connection cable is specially manufactured
for applications with mobile use. The special
PUR outer jacket allows use in many industrial
environments of general machine and plant
construction.


Characteristic

These pre-assembled cables can be produced


in any lengths and also with
customer-specific modifications.


Note

Please observe the installation instructions


for laying cables in cable carriers on Page 36
and the drive or controller manufacturers
information about maximum permitted
cable length.


Manufacturer
Designation
6FX8002-2AD00
6FX8002-2AH00
6FX8002-2CA11
6FX8002-2CA15
6FX8002-2CA31
6FX8002-2CA51
6FX8002-2CA61
6FX8002-2CA72
6FX8002-2CB31
6FX8002-2CB51

Helukabel
Designation
2AD00 DESINA PUR
2AH00 DESINA PUR
2CA11 DESINA PUR
2CA15 DESINA PUR
2CA31 DESINA PUR
2CA51 DESINA PUR
2CA61 DESINA PUR
2CA72 DESINA PUR
2CB31 DESINA PUR
2CB51 DESINA PUR

Helukabel
Part no.
660014
87328
660018
660019
660021
660023
660024
660676
650122
660031


Manufacturer
Designation
6FX8002-2CC11
6FX8002-2CD01
6FX8002-2CF02
6FX8002-2CG00
6FX8002-2CH00
6FX8002-2EQ10
6FX8002-2CA21
6FX8002-2CE02
6FX8002-2CM00
6FX8002-2CE07

Helukabel
Designation
2CC11 DESINA PUR
2CD01 DESINA PUR
2CF02 DESINA PUR
2CG00 DESINA PUR
2CH00 DESINA PUR
2EQ10 PUR DESINA
2CA21 DESINA PUR
2CE02 DESINA PUR
2CM00 DESINA PUR
2CE07 DESINA PUR

Helukabel
Part no.
660032
660033
89293
660034
660035
660038
660020
660677
660678
660679

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled servo motor cables


for fixed laying

Base line for use on SIEMENS drive systems (Drive Cliq*)




Technical data

Temperature range
moving 0 C to +60 C
not moving -20 C to +80 C
Bending radius
moving 20 x cable diameter
not moving 5 x cable diameter
Max. acceleration
2 m/s2
Bending cycles
100,000 for 20x cable diameter
Nominal voltage
(UL/CSA) 1000 V
(power + signal)
Nominal voltage
(VDE) U0/U 0.6/1kV (power)
24 V (signal)
Test voltage, power cores 4 kV
Test voltage, signal cores 1 kV
Insulation resistance 20 MOhm x km


Cable structure

Power supply cores


Bare copper, according to IEC60228CL.6
PVC core insulation
Core identification U/L1/C/L+
V/L2
W/L3/D/L Earth core KVIIR]IPPS[
Signal cores
Copper conductors, bare
TPE-E core insulation
Core identification black
white
Cores twisted in pairs
Shield, tin-plated copper braiding
Complete shield made of tin-plated
copper braiding
Coverage approx. 80%
PVC outer jacket
Sheath colour, orange (RAL 2003)

Application
This high quality pre-assembled motor
connection cable is specially manufactured
for applications with static installation. The
special PVC outer jacket allows use in many
industrial environments of general machine
and plant construction.


Characteristic

Economical alternatives to the cable carrier


compatible cable types which otherwise meet
all requirements of the servo drive
manufacturers. These pre-assembled cables
can be produced in any lengths and also with
customer-specific modifications.


Note

Please observe the drive or controller


manufacturer's information about maximum
permitted cable length.

Approbations
Desina (ISO 23570)
VDE
UL/CSA


Manufacturer
Designation
6FX5002-5CS01
6FX5002-5CS11
6FX5002-5CS21
6FX5002-5CS31
6FX5002-5CS41
6FX5002-5CS51
6FX5002-5CS61
6FX5002-5CS13

Helukabel
Designation
5CS01 DESINA PVC
5CS11 DESINA PVC
5CS21 DESINA PVC
5CS31 DESINA PVC
5CS41 DESINA PVC
5CS51 DESINA PVC
5CS61 DESINA PVC
5CS13 DESINA PVC

Helukabel
Part no.
660855
660856
660857
660858
660859
660860
660861
660862


Manufacturer
Designation
6FX5002-5DS01
6FX5002-5DS11
6FX5002-5DS21
6FX5002-5DS31
6FX5002-5DS41
6FX5002-5DS51
6FX5002-5DS61
6FX5002-5DS13

Helukabel
Designation
5DS01 DESINA PVC
5DS11 DESINA PVC
5DS21 DESINA PVC
5DS31 DESINA PVC
5DS41 DESINA PVC
5DS51 DESINA PVC
5DS61 DESINA PVC
5DS13 DESINA PVC

Helukabel
Part no.
660863
660864
660865
660866
660867
660868
660869
660870

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.
* Drive Cliq is registered trademark from Siemens AG.

U9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled servo motor cables


for mobile use

Base line for use on SIEMENS drive systems (Drive Cliq*)




Technical data

Temperature range
moving -20 C to +60 C
not moving -50 C to +80 C
Bending radius
moving 10 x cable diameter
not moving 7 x cable diameter
Max. acceleration
5 m/s2
Bending cycles
10 million for 12x cable diameter
Operating voltage /U 600/1000 V (VDE)
1000V (UL)
Test voltage, power cores 4 kV
Test voltage, signal cores 2 kV
Insulation resistance 500 MOhm x km


Approbations

Desina (ISO 23570)


UL/CSA

Cable structure

Power supply cores


Bare copper, extra fine wire conductor
according to DINVDE0295CL.6
high quality PP core insulation
Core identification U/L1/C/L+
V/L2
W/L3/D/L Earth core KVIIR]IPPS[
Signal cores
Copper conductors, bare
High quality PP core insulation
Core identification black
white
Cores twisted in pairs
Shielding screened with tin-plated copper
wires
Complete shield made of tin-plated
copper braiding
Coverage approx. 80%
PUR outer sheath
Sheath colour, orange (RAL 2003)

Application
This high quality pre-assembled motor
connection cable is specially manufactured
for applications with mobile use. The special
PUR outer jacket allows use in many industrial
environments of general machine and plant
construction.


Characteristic

These pre-assembled cables can be produced


in any lengths and also with
customer-specific modifications.


Note

Please observe the installation instructions


for laying cables in cable carriers on Page 36
and the drive or controller manufacturers
information about maximum permitted
cable length.


Manufacturer
Designation
6FX8002-5CS01
6FX8002-5CS11
6FX8002-5CS21
6FX8002-5CS31
6FX8002-5CS41
6FX8002-5CS51
6FX8002-5CS61
6FX8002-5CS13

Helukabel
Designation
5CS01 DESINA PUR
5CS11 DESINA PUR
5CS21 DESINA PUR
5CS31 DESINA PUR
5CS41 DESINA PUR
5CS51 DESINA PUR
5CS61 DESINA PUR
5CS13 DESINA PUR

Helukabel
Part no.
660871
660872
660873
660874
660875
660876
660877
660878


Manufacturer
Designation
6FX8002-5DS01
6FX8002-5DS11
6FX8002-5DS21
6FX8002-5DS31
6FX8002-5DS41
6FX8002-5DS51
6FX8002-5DS61
6FX8002-5DS13

Helukabel
Designation
5DS01 DESINA PUR
5DS11 DESINA PUR
5DS21 DESINA PUR
5DS31 DESINA PUR
5DS41 DESINA PUR
5DS51 DESINA PUR
5DS61 DESINA PUR
5DS13 DESINA PUR

Helukabel
Part no.
660879
660880
660881
660882
660883
660884
660885
660886

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.
* Drive Cliq is registered trademark from Siemens AG.

U 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled feedback cables


for fixed laying

Base line for use on SIEMENS drive systems (Drive Cliq*)




Technical data

Temperature range
moving -20 C to +60 C
not moving -20 C to +80 C
Bending radius
moving 10 x cable diameter
not moving 5 x cable diameter
Max. acceleration
2 m/s2
Bending cycles
100000 for 10x cable diameter
max. operating voltage 30 V AC (UL)
Test voltage 500 V / 50 Hz / 1min
Insulation resistance 1 GOhm x km
Conductor resistance
Core AWG26 135 ohms/km
Core AWG22 62 ohms/km
Characteristic impedance AWG26 pairs
from 1 MHz to 100 MHz 100+/-15O hm
Operating capacitance AWG26 pairs
for 800 Hz rated 50 nF/km


Approbations
UL/CSA

Cable structure

Application

Bare copper conductor, 7 strands


Polyolefin core insulation
Complete shield aluminium foil coated
with plastic, braiding made of tin-plated
copper wires
Coverage approx. 85%
PUR outer sheath
Sheath colour green
Structure/colour code
(2xAWG22+2x2xAWG26)
Colour code
Pair AWG22: red + black Pair 1 AWG26:
green + yellow Pair 2 AWG26: pink + blue
Connector data
RJ45 connector CAT5
Material: nickel-plated PBT/brass
Contacts 30u" Au/Ni
Rated voltage: 50 V DC/35 V AC
Operating temperature: -20 C to + 120 C
Mating cycles: 1000
Cover
zinc die-cast
zinc die-cast / PBT, blue
PBT blue
PBT black

This high quality pre-assembled sensor


connection cable is specially manufactured
for applications with static installation. The
special PVC outer jacket allows use in many
industrial environments of general machine
and plant construction.


Characteristic

Economical alternatives to the cable carrier


compatible cable types which otherwise meet
all requirements of the servo drive
manufacturers. These pre-assembled cables
can be produced in any lengths and also with
customer-specific modifications.


Note

Please observe the drive or controller


manufacturer's information about maximum
permitted cable length.

Manufacturer
Designation
6FX5002-2DC00
6FX5002-2DC10

Helukabel
Designation
2DC00 DESINA PUR
2DC10 DESINA PUR

Helukabel
Part no.
660887
660888


Manufacturer
Designation
6FX5002-2DC20

Helukabel
Designation
2DC20 DESINA PUR

Helukabel
Part no.
660889

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.
* Drive Cliq is registered trademark from Siemens AG.

U 11
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled feedback cables


for mobile use

Base line for use on SIEMENS drive systems (Drive Cliq*)




Technical data

Temperature range
moving -20 C to +60 C
not moving -20 C to +80 C
Bending radius
moving 15 x cable diameter
not moving 5 x cable diameter
Max. acceleration
5 m/s2
Bending cycles
2 million for 15x cable diameter
max. operating voltage 30 V
Test voltage 500 V / 50 Hz / 1min
Insulation resistance 1 GOhm x km
Conductor resistance
Core AWG26 135 ohms/km
Core AWG22 62 ohms/km
Characteristic impedance 0.15mm2
pairs
from 1 MHz to 100 MHz 100+/-15O hm
Operating capacitance 0.15mm2 pairs
for 800 Hz rated 50 nF/km


Approbations
UL/CSA

Cable structure

Application

0.15 mm2 Bare copper conductor, 19


strands
0.38 mm2 Tin-plated copper conductor, 19
strands
Polyolefin core insulation
Complete shield aluminium foil coated
with plastic, braiding made of tin-plated
copper wires
Coverage approx. 85%
PUR outer sheath
Sheath colour green
Structure/colour code
(2x0.38mm2)+2x(2x0.15mm2)
Colour code
Pair 0.38mm2: red + black Pair 1 0.15mm2:
green + yellow Pair 2 0.15mm2: pink + blue
Connector data
RJ45 connector CAT5
Material: nickel-plated PBT/brass
Contacts 30u" Au/Ni
Rated voltage: 50 V DC/35 V AC
Operating temperature: -20 C to + 120 C
Mating cycles: 1000
Cover
zinc die-cast
zinc die-cast / PBT, blue
PBT blue
PBT black

This high quality pre-assembled sensor


connection cable is specially manufactured
for applications with mobile use. The special
PUR outer jacket allows use in many industrial
environments of general machine and plant
construction.


Characteristic

These pre-assembled cables can be produced


in any lengths and also with
customer-specific modifications.


Note

Please observe the installation instructions


for laying cables in cable carriers on Page 36
and the drive or controller manufacturers
information about maximum permitted
cable length.


Manufacturer
Designation
6FX8002-2DC00
6FX8002-2DC10

Helukabel
Designation
2DC00 DESINA PUR
2DC10 DESINA PUR

Helukabel
Part no.
660890
660891


Manufacturer
Designation
6FX8002-2DC20

Helukabel
Designation
2DC20 DESINA PUR

Helukabel
Part no.
660892

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.
* Drive Cliq is registered trademark from Siemens AG.

U 12
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled servo motor cables


for mobile use (PVC)

Base line for use on REXROTH drive systems




Technical data

Wire temperature range


moving -30 C to +80 C
not moving -50 C to +90 C
Bending radius
moving 10 x cable diameter
not moving 7 x cable diameter
Max. acceleration
4 m/s2
Bending cycles
5 million for 10x cable diameter
Nominal voltage
(UL/CSA) 1000 V
Test voltage, power cores 4 kV
Test voltage, signal cores 2 kV
Insulation resistance 20 MOhm x km


Approbations
Desina (ISO 23570)
UL/CSA

Cable structure

Power supply cores


Bare copper, extra fine wire conductor
according to DINVDE0295CL.6
PETP core insulation
Core identification 1, 2, 3
Earth core KVIIR]IPPS[
Signal cores
Bare copper, extra fine wire conductor
according to DINVDE0295CL.6
Core insulation PETP
Core identification
Pair 1: 5.6
Pair 2: 7.8
Cores twisted in pairs
Shielding aluminium/polyester foil
Drain wire
tin-plated copper braiding
Complete shield made of tin-plated
copper braiding
Coverage approx. 85%
PVC outer jacket
Sheath colour, orange (RAL 2003)

Application
This high quality pre-assembled motor
connection cable is specially manufactured
for applications with high mechanical stress.
The special PVC outer jacket allows use in
many industrial environments of general
machine and plant construction.


Characteristic

Particularly suitable for use with small


bending radii and high acceleration. These
pre-assembled cables can be produced in any
lengths and also with customer-specific
modifications.


Note

Please observe the installation instructions


for laying cables in cable carriers on Page 36
and the drive or controller manufacturers
information about maximum permitted
cable length.

Helukabel
Designation
motor cable 4009 PVC
motor cable 4017 PVC
motor cable 4039 PVC
motor cable 4060 PVC
motor cable 4055 PVC

Helukabel
Part no.
660680
660681
660682
660683
660684


Helukabel
Designation
motor cable 4020 PVC
motor cable 4018 PVC
motor cable 4016 PVC
motor cable 4119 PVC

Helukabel
Part no.
660685
660686
660687
660688

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 13
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled servo motor cables


for mobile use (PUR)

Base line for use on REXROTH drive systems




Technical data

Wire temperature range


moving -20 C to +60 C
not moving -50 C to +80 C
Bending radius
moving 10 x cable diameter
not moving 7 x cable diameter
Max. acceleration
5 m/s2
Bending cycles
5 million for 10x cable diameter
Nominal voltage
(UL/CSA) 1000 V
Test voltage, power cores 4 kV
Test voltage, signal cores 2 kV
Insulation resistance 10 MOhm x km


Approbations

Desina (ISO 23570)


UL/CSA

Cable structure

Power supply cores


Bare copper, extra fine wire conductor
according to DINVDE0295CL.6
PETP core insulation or high quality
PP core insulation
Core identification 1, 2, 3
Earth core KVIIR]IPPS[
Signal cores
Bare copper, extra fine wire conductor
according to DINVDE0295CL.6
PETP or high quality PP core insulation
Core identification
Pair 1: 5,6
Pair 2: 7,8
Cores twisted in pairs
Shielding aluminium/polyester foil
Drain wire
tin-plated copper braiding
Complete shield made of tin-plated
copper braiding
Coverage approx. 80%
PUR outer sheath
Sheath colour, orange (RAL 2003)

Application
This high quality pre-assembled motor
connection cable is specially manufactured
for applications with high mechanical stress.
The special PUR outer jacket allows use in
many industrial environments of general
machine and plant construction.


Characteristic

Particularly suitable for use with small


bending radii and high acceleration. These
pre-assembled cables can be produced in any
lengths and also with customer-specific
modifications.


Note
Please observe the installation instructions
for laying cables in cable carriers on Page 36
and the drive or controller manufacturers
information about maximum permitted
cable length.


Manufacturer
Designation
IKG4008
IKG4009
IKG4017
IKG4077
IKG4029
IKG4039
IKG4028
IKG4073
IKG4071
IKG4072
IKG4053
IKG4060
IKG4055
IKG4063
IKG4070
IKG4068
IKG4067
IKG4083
IKG4090
IKG4087
IKG4103
IKG4110
IKG4107
IKG4123

Helukabel
Designation
motor cable 4008 PUR
Motorleitung 4009 PUR
Motorleitung 4017 PUR
Motorleitung 4077 PUR
Motorleitung 4029 PUR
Motorleitung 4039 PUR
Motorleitung 4028 PUR
Motorleitung 4073 PUR
motor cable 4071 PUR
Motorleitung 4072 PUR
motor cable 4053 PUR
motor cable 4060 PUR
motor cable 4055 PUR
motor cable 4063 PUR
motor cable 4070 PUR
motor cable 4068 PUR
motor cable 4067 PUR
motor cable 4083 PUR
motor cable 4090 PUR
motor cable 4087 PUR
motor cable 4103 PUR
motor cable 4110 PUR
motor cable 4107 PUR
motor cable 4123 PUR

Helukabel
Part no.
660090
660091
660092
660093
660095
660096
660097
660099
660100
660101
660103
660104
660105
660108
660109
660110
660111
660114
660115
660116
660119
660120
660121
660124


Manufacturer
Designation
IKG4130
IKG4127
IKG4143
IKG4150
IKG4147
IKG4163
IKG4170
IKG4167
IKG4183
IKG4200
IKG4186
IKG4203
IKG4210
IKG4204
IKG4223
IKG4224
IKG4013
IKG4020
IKG4018
IKG4016
IKG4033
IKG4050
IKG4035
IKG4037

Helukabel
Designation
motor cable 4130 PUR
motor cable 4127 PUR
motor cable 4143 PUR
motor cable 4150 PUR
motor cable 4147 PUR
motor cable 4163 PUR
motor cable 4170 PUR
motor cable 4167 PUR
motor cable 4183 PUR
motor cable 4200 PUR
Motorleitung 4186 PUR
motor cable 4203 PUR
motor cable 4210 PUR
motor cable 4204 PUR
motor cable 4223 PUR
motor cable 4224 PUR
motor cable 4013 PUR
motor cable 4020 PUR
motor cable 4018 PUR
motor cable 4016 PUR
motor cable 4033 PUR
motor cable 4050 PUR
motor cable 4035 PUR
motor cable 4037 PUR

Helukabel
Part no.
660125
660126
660129
660130
660131
660134
660135
660136
660139
660140
660141
660144
660145
660146
660149
660150
660153
660154
660155
660156
660157
660158
660159
660160

Continuation

U 14
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled servo motor cables


for mobile use (PUR)

Base line for use on REXROTH drive systems




Manufacturer
Designation
IKG4136
IKG4155
IKG4176
IKG4186
IKG4172
IKG4173
IKG4174
IKG4115
IKG4140
IKG4116
RKL4421
IKG4117
IKG4177
IKG4118
IKG4215
IKG4175
IKG4169
IKG4138
IKG4134
IKG4119
IKG4120
IKG4137
RKL4302
RKL4303
RKL4300
RKL4301
RKL4306
RKL4307
RKL4308
RKL4309
RKL4310

Helukabel
Designation
motor cable 4136 PUR
motor cable 4155 PUR
Motorleitung 4176
motor cable 4186
motor cable 4172
motor cable 4173 PUR
motor cable 4174
motor cable 4115
motor cable 4140
motor cable 4116 PUR
motor cable 4421 PUR
motor cable 4117 PUR
motor cable 4177 PUR
motor cable 4118 PUR
motor cable 4215 PUR
motor cable 4175 PUR
motor cable 4169 PUR
motor cable 4138 PUR
motor cable 4134 PUR
motor cable 4119 PUR
motor cable 4120 PUR
motor cable 4137 PUR
motor cable 4302 PUR
motor cable 4303 PUR
motor cable 4300 PUR
motor cable 4301 PUR
motor cable 4306 PUR
motor cable 4307 PUR
motor cable 4308 PUR
motor cable 4309 PUR
motor cable 4310 PUR

Helukabel
Part no.
660689
660690
660691
660692
660693
660694
660695
660696
660697
660698
660699
660700
660701
660702
660703
660704
660705
660706
660707
660708
660709
660710
660627
660711
660712
660713
660714
660715
660716
660717
660718


Manufacturer
Designation
RKL4313
RKL4314
RKL4315
RKL4317
RKL4318
RKL4401
RKL4421
RKL4431
RKL4441
RKL4421
RKL4421
RKL4421
RKL4421
RKL4421
RKL4421
RKL4421
RKL4421
RKL4421
RKL4421
RKL4421
RKL4421
RKL4421
RKL4421
RKL4421
RKL4421
RKL4421
RKL4421
RKL4421
RKL4421
RKL4421
RKL4421

Helukabel
Designation
motor cable 4313 PUR
motor cable 4314 PUR
motor cable 4315 PUR
motor cable 4317 PUR
motor cable 4318 PUR
motor cable 4401 PUR
motor cable 4421 PUR
motor cable 4431 PUR
motor cable 4441 PUR
motor cable 4421 PUR
motor cable 4421 PUR
motor cable 4421 PUR
motor cable 4421 PUR
motor cable 4421 PUR
motor cable 4421 PUR
motor cable 4421 PUR
motor cable 4421 PUR
motor cable 4421 PUR
motor cable 4421 PUR
motor cable 4421 PUR
motor cable 4421 PUR
motor cable 4421 PUR
motor cable 4421 PUR
motor cable 4421 PUR
motor cable 4421 PUR
motor cable 4421 PUR
motor cable 4421 PUR
motor cable 4421 PUR
motor cable 4421 PUR
motor cable 4421 PUR
motor cable 4421 PUR

Helukabel
Part no.
660719
660720
660721
660722
660723
660724
660725
660726
660727
660728
660729
660730
660732
660733
660734
660735
660736
660737
660739
660740
660741
660742
660743
660744
660745
660746
660747
660748
660749
660750
660751

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 15
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled feedback cables


for mobile use (PVC)

Base line for use on REXROTH drive systems




Technical data

Temperature range
moving -10 C to +80 C
not moving -40 C to +80 C
Bending radius
moving 12 x cable diameter
not moving 8 x cable diameter
Max. acceleration
4 m/s2
Bending cycles
5 million for 12x cable diameter
Operating voltage 30 V
Test voltage 1500 V
Insulation resistance 100 MOhm x km


Cable structure

Application

Copper conductors
Polyolefin core insulation
Complete shield, tin-plated copper
braiding
Coverage approx. 85%
PVC outer jacket
Sheath colour orange
Structure/colour code
(2x0.5+4x2x0.25) wh, bn, bn+gn, rd+bl,
bu+vio, gy+pk
(2x1.0+4x2x0.25) wh, bn, bn+gn, rd+bl,
bu+vio, gy+pk

This high quality pre-assembled sensor


connection cable is specially manufactured
for applications with high mechanical stress.
The special PVC outer jacket allows use in
many industrial environments of general
machine and plant construction.


Approbations

Note

UL/CSA

Please observe the installation instructions


for laying cables in cable carriers on Page 36
and the drive or controller manufacturers
information about maximum permitted
cable length.


Helukabel
Designation
feedback cables 4374 PVC
feedback cables 4042 PVC
feedback cables 4375 PVC

Characteristic

Particularly suitable for use with small


bending radii and high acceleration. These
pre-assembled cables can be produced in any
lengths and also with customer-specific
modifications.

Helukabel
Part no.
660752
660753
660754


Helukabel
Designation
feedback cables 4103 PVC
feedback cables 4200 PVC

Helukabel
Part no.
660755
660756

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 16
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled feedback cables


for mobile use (PUR)

Base line for use on REXROTH drive systems




Technical data

Cable structure

Application
This high quality pre-assembled sensor
connection cable is specially manufactured
for applications with high mechanical stress.
The special PUR outer jacket allows use in
many industrial environments of general
machine and plant construction.


Approbations

Copper conductors
high quality PP core insulation / polyolefin
core insulation
Complete shield, tin-plated copper
braiding
Coverage approx. 80%
PUR outer sheath
Sheath colour orange
(for (2x0.5+4x2x0.25) green also possible)
Structure/colour code
(2x0.5+4x2x0.25) wh, bn, bn+gn, rd+bl,
bu+vio, gy+pk
(2x1.0+4x2x0.25) wh, bn, bn+gn, rd+bl,
bu+vio, gy+pk
(4x2x0.14+4x1.0+(4x0.14)) gy+pk,
ye+vio, gn+bn, rd+bl, bu, wh/gn, bn/gn,
wh, gn/bl, bu/bl,ye/bl, rd/bl

Temperature range
moving 0 C to +60 C
not moving -40 C to +60 C
Bending radius
moving 10 x cable diameter
not moving 8 x cable diameter
Max. acceleration
5 m/s2
Bending cycles
10 million for 12x cable diameter
Operating voltage
300 V AC according to VDE
30 V according to UL/CSA
Test voltage 1000 V (0.14 mm 2 0.5 kV)
Insulation resistance 100 MOhm x km

UL/CSA

Characteristic

Particularly suitable for use with small


bending radii and high acceleration. These
pre-assembled cables can be produced in any
lengths and also with customer-specific
modifications.


Note

Please observe the installation instructions


for laying cables in cable carriers on Page 36
and the drive or controller manufacturers
information about maximum permitted
cable length.

Manufacturer
Designation
IKS4374
IKS4042
IKS4375
IKS4040
IKS4041
IKS4020
IKS4043
IKS4103

Helukabel
Designation
feedback cables 4374 PUR
feedback cables 4042 PUR
feedback cables 4375 PUR
feedback cables 4040 PUR
feedback cables 4041 PUR
feedback cables 4020 PUR
feedback cables 4043 PUR
feedback cables 4103 PUR

Helukabel
Part no.
660260
660757
660263
660758
660759
660266
660760
660272


Manufacturer
Designation
IKS0205
IKS0204
IKS0206
IKS4142
IKS4038
IKS4001
IKS4019
RKG4200

Helukabel
Designation
feedback cables 0205 PUR
feedback cables 0204 PUR
feedback cables 0206 PUR
feedback cables 4142 PUR
feedback cables 4038 PUR
feedback cables 4001 PUR
feedback cables 4019 PUR
feedback cables 4200 PUR

Helukabel
Part no.
660275
660276
660277
660283
660761
660313
660314
660628

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 17
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled servo motor cables


for fixed laying

Base line for use on LENZE drive systems of the type Global Drive


Technical data

Temperature range
moving -20 C to +70 C
not moving -20 C to +80 C
Bending radius
moving 18 x cable diameter
not moving 9 x cable diameter
Max. acceleration
5 m/s2
Bending cycles
50,000 for 18x cable diameter
Nominal voltage U0/U 0.6/1kV
Test voltage 4 kV
Insulation resistance 500 MOhm x km


Approbations

Desina (ISO 23570)


VDE
UL/CSA

Cable structure

Power supply cores


Copper conductors, bare
high quality PP core insulation
Core identification 1, 2, 3
Earth core KVIIR]IPPS[
Signal cores
Copper conductors, bare
High quality PP core insulation
Core identification black
white
Shielding aluminium/polyester foil
screened with tin-plated copper wires
Complete shield made of tin-plated
copper braiding
Coverage approx. 80%
PVC outer jacket
Sheath colour, orange (RAL 2003)

Application
This high quality pre-assembled motor
connection cable is specially manufactured
for applications with static installation. The
special PVC outer jacket allows use in many
industrial environments of general machine
and plant construction.


Characteristic

Economical alternatives to the cable carrier


compatible cable types which otherwise meet
all requirements of the servo drive
manufacturers. These pre-assembled cables
can be produced in any lengths and also with
customer-specific modifications.


Note

Please observe the drive or controller


manufacturer's information about maximum
permitted cable length.


Manufacturer
Designation
EWLMxxxGM-015C
EWLMxxxGM-015C
EWLMxxxGM-040
-

Helukabel
Designation
motor cable GM 015
motor cable GM 015
motor cable GM 040
motor cable GM 060

Helukabel
Part no.
660334
660482
660350
660731


Manufacturer
Designation
EWLMxxxGM-100
EWLMxxxGM-040I
EWLMxxxGM-100I

Helukabel
Designation
motor cable GM 100
motor cable GM 040I
motor cable GM 060I
motor cable GM 100I

Helukabel
Part no.
660738
660762
660763
660764

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 18
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled servo motor cables


for mobile use

Base line for use on LENZE drive systems of the type Global Drive


Technical data

Wire temperature range


moving 0 C to +60 C
not moving -30 C to +80 C
Bending radius
moving 12 x cable diameter
not moving 7 x cable diameter
Max. acceleration
4 m/s2
Bending cycles
10 million for 12x cable diameter
Operating voltage 1,000 V
Test voltage, power cores 3 kV
Test voltage, control cores 1.5 kV
Insulation resistance, power cores
5000 MOhm x km
Insulation resistance, signal cores
20 MOhm x km


Approbations

Cable structure

Power supply cores


Bare copper conductor according to
DINVDE0295CL.6
Polyolefin polymer core insulation
Core identification 1, 2, 3
Earth core KVIIR]IPPS[
Signal cores
Copper conductors, bare
Polyolefin/polymer core insulation
Core identification black
white
Cores twisted in pairs
Shield, tin-plated copper braiding
Complete shield made of tin-plated
copper braiding
Coverage approx. 85%
PUR outer sheath
Sheath colour, orange (RAL 2003)

Desina (ISO 23570)


UL/CSA

Application
This high quality pre-assembled motor
connection cable is specially manufactured
for applications with high mechanical stress.
The special PUR outer jacket allows use in
many industrial environments of general
machine and plant construction.


Characteristic

Particularly suitable for use with small


bending radii and high acceleration. These
pre-assembled cables can be produced in any
lengths and also with customer-specific
modifications.


Note

Please observe the installation instructions


for laying cables in cable carriers on Page 36
and the drive or controller manufacturers
information about maximum permitted
cable length.

Manufacturer
Designation
EWLMxxxGMS-025
EWLMxxxGMS-040
-

Helukabel
Designation
motor cable GMS 015
motor cable GMS 025
motor cable GMS 040
motor cable GMS 060

Helukabel
Part no.
660500
660648
660766
660767


Manufacturer
Designation
-

Helukabel
Designation
motor cable GMS 100
motor cable GMS 040I
motor cable GMS 060I
motor cable GMS 100I

Helukabel
Part no.
660768
660769
660770
660771

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 19
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled feedback cables


for fixed laying

Base line for use on LENZE drive systems of the type Global Drive


Technical data

Temperature range
not moving -25 C to +80 C
Bending radius
not moving 8 x outer
Operating voltage 30 V
Test voltage 1000 V
Insulation resistance 10 MOhm x km


Approbations

Desina (ISO 23570)


UL/CSA

Cable structure

Application

Tinned copper conductors


PVC or PE core insulation
Shield, tin-plated copper braiding
Coverage approx. 75%
PVC outer jacket
Sheath colour green
Structure/colour code
(3x(2x0.14)+2x(0.5))
ye+bl, gn+bl, rd+bl, wh, bl
(4x(2x0.14)+2x(1,0)
ye+gn, pk+gy, rd+bu, bl+vio, wh, bn

This high quality pre-assembled sensor


connection cable is specially manufactured
for applications with static installation. The
special PVC outer jacket allows use in many
industrial environments of general machine
and plant construction.


Characteristic

Economical alternatives to the cable carrier


compatible cable types which otherwise meet
all requirements of the servo drive
manufacturers. These pre-assembled cables
can be produced in any lengths and also with
customer-specific modifications.


Note

Please observe the drive or controller


manufacturers information about maximum
permitted cable length.



Manufacturer
Designation
EWLRxxxGM-T
EWLRxxxGM-T

Helukabel
Designation
feedback cables GM-T
encoder cables GM-T

Helukabel
Part no.
660335
660772


Manufacturer
Designation
EWLDxxxGGBS93

Helukabel
Designation
system cable GGBS 93

Helukabel
Part no.
660773

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 20
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled feedback cables


for mobile use

Base line for use on LENZE drive systems of the type Global Drive


Technical data

Temperature range
moving -5 C to +70 C
not moving -40 C to +80 C
Bending radius
moving 15 x cable diameter
not moving 8 x cable diameter
Max. acceleration
3 m/s2
Bending cycles
2 million for 15x cable diameter
Operating voltage 30 V
Test voltage 1000 V


Approbations
Desina (ISO 23570)
UL/CSA

Cable structure

Application

Tinned copper conductors


Polyester/polyolefin core insulation
Shield, tin-plated copper braiding
Coverage approx. 80%
PUR outer sheath
Sheath colour green
(0-000000-02866 orange)
Structure/colour code
(3x(2x0.14)+2x(0.5))
ye+bl, gn+bl, rd+bl, wh, bl
(3x(2x0.14)+2x(0.5))
ye+gn, rd+gy, rd+bu, wh, bn
(4x(2x0.14)+2x(1.0)
ye+gn, pk+gy, rd+bu, bl+vio, wh, bn
(4x(2x0.14)+2x(0.5)
ye+gn, pk+gy, rd+bu, bl+vio, wh, bn

This high quality pre-assembled sensor


connection cable is specially manufactured
for applications with mobile use. The special
PUR outer jacket allows use in many industrial
environments of general machine and plant
construction.


Helukabel
Designation
feedback cables GMS-T

Helukabel
Part no.
660445

Characteristic

These pre-assembled cables can be produced


in any lengths and also with
customer-specific modifications.


Note

Please observe the installation instructions


for laying cables in cable carriers on Page 36
and the drive or controller manufacturers
information about maximum permitted
cable length.


Helukabel
Designation
encoder cables GMS-T

Helukabel
Part no.
660774

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 21
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled fan cables


for fixed laying

Base line for use on LENZE drive systems of the type Global Drive


Technical data

Wire temperature range


moving -5 C to +70 C
not moving -40 C to +70 C
Bending radius
moving 8 x outer
not moving 4 x outer
Nominal voltage (HAR) U0/U 300/500V
Nominal voltage (UL/CSA) U 600V
Test voltage, power cores 3 kV
Insulation resistance 20 MOhm x km


Cable structure

Application

Bare copper conductor, fine wire stranded


PVC core insulation
Core identification 1, 2, 3
Earth core KVIIR]IPPS[
PVC outer jacket
Sheath colour grey

This high quality pre-assembled fan cable is


specially manufactured for applications with
static installation. The special PUR outer jacket
allows use in many industrial environments
of general machine and plant construction.


Characteristic

These pre-assembled cables can be produced


in any lengths and also with
customer-specific modifications.


Approbations

Note

UL/CSA

Please observe the drive or controller


manufacturer's information about maximum
permitted cable length.


Manufacturer
Designation
EWLLxxxGM

Helukabel
Designation
fan cables GM

Helukabel
Part no.
660351

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 22
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled fan cables


for mobile use

Base line for use on LENZE drive systems of the type Global Drive


Technical data

Wire temperature range


moving -5 C to +80 C
not moving -40 C to +80 C
Bending radius
moving 8 x outer
not moving 4 x outer
Nominal voltage (UL/CSA) U 600V
Test voltage, power cores 4 kV
Insulation resistance 20 MOhm x km


Cable structure

Application

Copper conductors, bare, fine wire


stranded
PVC core insulation
Core identification 1, 2, 3
Earth core KVIIR]IPPS[
PUR outer sheath
Sheath colour grey

This high quality pre-assembled fan cable is


specially manufactured for applications with
high mechanical stress. The special PUR outer
jacket allows use in many industrial
environments of general machine and plant
construction.


Characteristic

Particularly suitable for use with small


bending radii and high acceleration. These
pre-assembled cables can be produced in any
lengths and also with customer-specific
modifications.


Approbations

UL/CSA

Note

Please observe the installation instructions


for laying cables in cable carriers on Page 36
and the drive or controller manufacturers
information about maximum permitted
cable length.


Manufacturer
Designation
EWLLxxxGMS

Helukabel
Designation
fan cables GMS

Helukabel
Part no.
660850

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 23
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled servo motor cables


for fixed laying

Base line for use on LENZE drive systems of the type L-force


Technical data

Wire temperature range


moving -20 C to +70 C
not moving -20 C to +80 C
Bending radius
moving 18 x cable diameter
not moving 9 x cable diameter
Max. acceleration
5 m/s2
Bending cycles
50,000 for 18x cable diameter
Operating voltage
(VDE) U0/U 0.6/1kV
Test voltage 4 kV
Insulation resistance 500 MOhm x km


Approbations

Desina (ISO 23570)


VDE
UL/CSA

Cable structure

Power supply cores


Copper conductors, bare
high quality PP core insulation
Core identification 1, 2, 3
Earth core KVIIR]IPPS[
Signal cores
Copper conductors, bare
High quality PP core insulation
Core identification black
white
Shielding aluminium/polyester foil
screened with tin-plated copper wires
Complete shield made of tin-plated
copper braiding
Coverage approx. 80%
PVC outer jacket
Sheath colour, orange (RAL 2003)


Application
This high quality pre-assembled motor
connection cable is specially manufactured
for applications with static installation. The
special PVC outer jacket allows use in many
industrial environments of general machine
and plant construction.


Characteristic

Economical alternatives to the cable carrier


compatible cable types which otherwise meet
all requirements of the servo drive
manufacturers. These pre-assembled cables
can be produced in any lengths and also with
customer-specific modifications.


Note

Please observe the drive or controller


manufacturer's information about maximum
permitted cable length.


Manufacturer
Designation
EYP 0006 A xxxx C01 A00
EYP 0008 A xxxx C02 A00
EYP 0005 A xxxx M02 A00
EYP 0006 A xxxx M02 A00
EYP 0007 A xxxx M03 A00

Helukabel
Designation
motor cable 0006AC01A00 PVC
motor cable 0008AC02A00 PVC
motor cable 0005AM02A00 PVC
motor cable 0006AM02A00 PVC
motor cable 0007AM03A00 PVC

Helukabel
Part no.
660776
660777
660778
660779
660780


Manufacturer
Designation
EYP 0008 A xxxx M03 A00
EYP 0009 A xxxx M03 A00
EYP 0003 A xxxx M01 A00
EYP 0004 A xxxx M01 A00
EYP 0005 A xxxx M01 A00

Helukabel
Designation
motor cable 0008AM03A00 PVC
motor cable 0009AM03A00 PVC
motor cable 0003AM01A00 PVC
motor cable 0004AM01A00 PVC
motor cable 0005AM01A00 PVC

Helukabel
Part no.
660781
660782
660783
660784
660785

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 24
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled servo motor cables


for mobile use

Base line for use on LENZE drive systems of the type L-force


Technical data

Wire temperature range


moving 0 C to +60 C
not moving -30 C to +80 C
Bending radius
moving 12 x cable diameter
not moving 7 x cable diameter
Max. acceleration
4 m/s2
Bending cycles
10 million for 12x cable diameter
Operating voltage 1,000V
Test voltage, power cores 3 kV
Test voltage, control cores 1.5 kV
Insulation resistance, power cores
5000 MOhm x km
Insulation resistance, signal cores
20 MOhm x km


Approbations

Cable structure

Power supply cores


Bare copper conductor according to
DINVDE0295CL.6
Polyolefin polymer core insulation
Core identification 1, 2, 3
Earth core KVIIR]IPPS[
Signal cores
Copper conductors, bare
Polyolefin/polymer core insulation
Core identification black
white
Cores twisted in pairs
Shielding screened with tin-plated copper
wires
Complete shield made of tin-plated
copper braiding
Coverage approx. 85%
PUR outer sheath
Sheath colour, orange (RAL 2003)

Application
This high quality pre-assembled motor
connection cable is specially manufactured
for applications with high mechanical stress.
The special PUR outer jacket allows use in
many industrial environments of general
machine and plant construction.


Characteristic

Particularly suitable for use with small


bending radii and high acceleration. These
pre-assembled cables can be produced in any
lengths and also with customer-specific
modifications.


Note

Please observe the installation instructions


for laying cables in cable carriers on Page 36

Desina (ISO 23570)


UL/CSA


Manufacturer
Designation
EYP 0013 A xxxx C01 A00
EYP 0015 A xxxx C02 A00
EYP 0012 A xxxx M02 A00
EYP 0013 A xxxx M02 A00
EYP 0014 A xxxx M03 A00

Helukabel
Designation
motor cable 0013AC01A00 PUR
motor cable 0015AC02A00 PUR
motor cable 0012AM02A00 PUR
motor cable 0013AM02A00 PUR
motor cable 0014AM03A00 PUR

Helukabel
Part no.
660786
660787
660788
660789
660790


Manufacturer
Designation
EYP 0015 A xxxx M03 A00
EYP 0016 A xxxx M03 A00
EYP 0010 A xxxx M01 A00
EYP 0011 A xxxx M01 A00
EYP 0012 A xxxx M01 A00

Helukabel
Designation
motor cable 0015AM03A00 PUR
motor cable 0016AM03A00 PUR
motor cable 0010AM01A00 PUR
motor cable 0011AM01A00 PUR
motor cable 0012AM01A00 PUR

Helukabel
Part no.
660791
660792
660793
660510
660794

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 25
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled feedback cables


for fixed laying

Base line for use on LENZE drive systems of the type L-force


Technical data

Temperature range
not moving -25 C to +80 C
Bending radius
not moving 8 x outer
Operating voltage 30 V
Test voltage 1000V
Insulation resistance 10 MOhm x km


Approbations

Desina (ISO 23570)


UL/CSA

Cable structure

Application

Tinned copper conductors


PVC/polyolefin core insulation
Shield, tin-plated copper braiding
Coverage approx. 75%
PVC outer jacket
Sheath colour green
Structure/colour code
(3x(2x0.14)+2x(0.5))
ye+bl, gn+bl, rd+bl, wh, bl
(4x(2x0.14)+2x(1.0)
ye+gn, pk+gy, rd+bu, bl+vio, wh, bn


This high quality pre-assembled sensor


connection cable is specially manufactured
for applications with static installation. The
special PVC outer jacket allows use in many
industrial environments of general machine
and plant construction.


Characteristic

Economical alternatives to the cable carrier


compatible cable types which otherwise meet
all requirements of the servo drive
manufacturers. These pre-assembled cables
can be produced in any lengths and also with
customer-specific modifications.


Note

Please observe the drive or controller


manufacturer's information about maximum
permitted cable length.



Manufacturer
Designation
EYD 0017 A xxxx W01 S01
EYD 0017 A xxxx W01 S02
EYD 0017 A xxxx W01 W01
EYD 0017 A xxxx W03 S01
EYD 0017 A xxxx W03 S02
EYD 0017 A xxxx W03 W01
EYF 0017 A xxxx A00 S01
EYF 0017 A xxxx A00 S02
EYF 0017 A xxxx F01 A00
EYF 0017 A xxxx F01 S01
EYF 0017 A xxxx F01 S02

Helukabel
Designation
feedback cables 0017AW01S01 PVC
feedback cables 0017AW01S02 PVC
feedback cables 0017AW01W01 PVC
feedback cables 0017AW03S01 PVC
feedback cables 0017AW03S02 PVC
feedback cables 0017AW03W01 PVC
feedback cables 0017AA00S01 PVC
feedback cables 0017AA00S02 PVC
feedback cables 0017AF01A00 PVC
feedback cables 0017AF01S01 PVC
feedback cables 0017AF01S02 PVC

Helukabel
Part no.
660795
660796
660797
660798
660799
660800
660801
660802
660803
660630
660804


Manufacturer
Designation
EYF 0028 A xxxx A00 G02
EYF 0018 A xxxx A00 S03
EYF 0018 A xxxx A00 W02
EYF 0018 A xxxx F02 A00
EYF 0028 A xxxx F02 G02
EYF 0018 A xxxx F02 S03
EYF 0018 A xxxx F02 W02
EYF 0021 A xxxx A00 S03
EYF 0021 A xxxx F03 A00
EYF 0021 A xxxx F03 S03

Helukabel
Designation
feedback cables 0028AA00G02 PVC
feedback cables 0018AA00S03 PVC
feedback cables 0018AA00W02 PVC
feedback cables 0018AF02A00 PVC
feedback cables 0028AF02G02 PVC
feedback cables 0018AF02S03 PVC
feedback cables 0018AF02W02 PVC
feedback cables 0021AA00S03 PVC
feedback cables 0021AF03A00 PVC
feedback cables 0021AF03S03 PVC

Helukabel
Part no.
660805
660806
660807
660808
660809
660810
660811
660812
660813
660814

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 26
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled feedback cables


for mobile use

Base line for use on LENZE drive systems of the type L-force


Technical data

Temperature range
moving -5 C to +70 C
not moving -40 C to +80 C
Bending radius
moving 15 x cable diameter
not moving 8 x cable diameter
Max. acceleration
3 m/s2
Bending cycles
2 million for 15x cable diameter
Operating voltage 30 V
Test voltage 1000 V


Approbations

Desina (ISO 23570) (except 0-000000-02866)


UL/CSA

Cable structure

Application

Tinned copper conductors


Polyester/polyolefin core insulation
Shield, tin-plated copper braiding
Coverage approx. 80%
PUR outer sheath
Sheath colour green
(0-000000-02866 orange)
Structure/colour code
(3x(2x0.14)+2x(0.5))
ye+bl, gn+bl, rd+bl, wh, bl
(3x(2x0.14)+2x(0.5))
ye+gn, rd+gy, rd+bu, wh, bn
(4x(2x0.14)+2x(1.0)
ye+gn, pk+gy, rd+bu, bl+vio, wh, bn
(4x(2x0.14)+2x(0.5)
ye+gn, pk+gy, rd+bu, bl+vio, wh, bn

This high quality pre-assembled sensor


connection cable is specially manufactured
for applications with mobile use. The special
PUR outer jacket allows use in many industrial
environments of general machine and plant
construction.


Manufacturer
Designation
EYD 0019 A xxxx F02 A00
EYD 0020 A xxxx A00 S04
EYF 0020 A xxxx A00 S05
EYF 0020 A xxxx F01 A00

Helukabel
Designation
feedback cables 0019AF02A00 PUR
feedback cables 0020AA00S04 PUR
feedback cables 0020AA00S05 PUR
feedback cables 0020AF01A00 PUR

Helukabel
Part no.
660815
660816
660817
660818

Characteristic

These pre-assembled cables can be produced


in any lengths and also with
customer-specific modifications.


Note

Please observe the installation instructions


for laying cables in cable carriers on Page 36
and the drive or controller manufacturers
information about maximum permitted
cable length.


Manufacturer
Designation
EYF 0020 A xxxx F01 S01
EYF 0020 A xxxx F01 S02
EYF 0022 A xxxx F03 A00

Helukabel
Designation
feedback cables 0020AF01S01 PUR
feedback cables 0020AF01S02 PUR
feedback cables 0022AF03A00 PUR

Helukabel
Part no.
660819
660820
660821

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 27
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled fan cables


for fixed laying

Base line for use on LENZE drive systems of the type L-force


Technical data

Wire temperature range


moving -5 C to +70 C
not moving -40 C to +70 C
Bending radius
moving 8 x cable diameter
not moving 4 x cable diameter
Nominal voltage (HAR) U0/U 300/500 V
Nominal voltage (UL/CSA) U 600 V
Test voltage, power cores 3 kV
Insulation resistance 20 MOhm x km


Cable structure

Power supply cores


Bare copper conductor, fine wire stranded
PVC core insulation
Core identification numbers
Earth core KVIIR]IPPS[
PVC outer jacket
Sheath colour grey

Application
This high quality pre-assembled fan cable is
specially manufactured for applications with
static installation. The special PVC outer jacket
allows use in many industrial environments
of general machine and plant construction.


Characteristic

These pre-assembled cables can be produced


in any lengths and also with
customer-specific modifications.


Approbations

Note

UL/CSA

Please observe the drive or controller


manufacturer's information about maximum
permitted cable length.


Manufacturer
Designation
EYL 0001 A xxxx L01 A00

Helukabel
Designation
fan cables 0001AL01A00 PVC

Helukabel
Part no.
660851


Manufacturer
Designation
EYL 0001 A xxxx L02 A00

Helukabel
Designation
fan cables 0001AL02A00 PVC

Helukabel
Part no.
660852

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 28
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled fan cables


for mobile use

Base line for use on LENZE drive systems of the type L-force


Technical data

Wire temperature range


moving -5 C to +80 C
not moving -40 C to +80 C
Bending radius
moving 8 x outer
not moving 4 x outer
Nominal voltage (UL/CSA) U 600V
Test voltage, power cores 4 kV
Insulation resistance 20 MOhm x km


Cable structure

Application

Copper conductors, bare, fine wire


stranded
TPE/PVC core insulation
Core identification 1, 2, 3
Earth core KVIIR]IPPS[
PUR outer sheath
Sheath colour grey

This high quality pre-assembled fan cable is


specially manufactured for applications with
high mechanical stress. The special PUR outer
jacket allows use in many industrial
environments of general machine and plant
construction.


Characteristic

Particularly suitable for use with small


bending radii and high acceleration. These
pre-assembled cables can be produced in any
lengths and also with customer-specific
modifications.


Approbations

UL/CSA

Note

Please observe the installation instructions


for laying cables in cable carriers on Page 36
and the drive or controller manufacturers
information about maximum permitted
cable length.


Manufacturer
Designation
EYL 0002 A xxxx L01 A00

Helukabel
Designation
fan cables 0001AL01A00 PVC

Helukabel
Part no.
660853


Manufacturer
Designation
EYL 0002 A xxxx L02 A00

Helukabel
Designation
fan cables 0002AL02A00 PVC

Helukabel
Part no.
660854

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 29
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled servo motor cables


for fixed laying

Base line for use on SEW drive systems




Technical data

Wire temperature range


not moving -40 C to +80 C
Bending radius
not moving 20 x cable diameter
Nominal voltage (UL) 1000 V
Nominal voltage (VDE) 0.6/1kV
Test voltage 4 kV
Insulation resistance 20 MOhm x km


Approbations

Desina (ISO 23570)


UL/CSA

Cable structure

Power supply cores


Copper conductors, bare
PP core insulation
Core identification U1, V2, W3
Earth core KVIIR]IPPS[
Signal cores
Copper conductors, bare
PP core insulation
Core identification 1, 2, 3
Cores twisted to triple
Shielding aluminium coated polyester foil
with drain wire + copper screen
Complete shield made of tin-plated
copper braiding
Coverage approx. 85%
PVC outer jacket
Sheath colour, orange (RAL 2003)

Application
This high quality pre-assembled motor
connection cable is specially manufactured
for applications with static installation. The
special PVC outer jacket allows use in many
industrial environments of general machine
and plant construction.


Characteristic

Economical alternatives to the cable carrier


compatible cable types which otherwise meet
all requirements of the servo drive
manufacturers. These pre-assembled cables
can be produced in any lengths and also with
customer-specific modifications.


Note

Please observe the drive or controller


manufacturer's information about maximum
permitted cable length.


Helukabel
Designation
motor cable 1991795 PVC 4x1,5
motor cable 1991892 PVC 4x1,5+3x1

Helukabel
Part no.
660822
660823


Helukabel
Designation
Motorleitung 1991914 PVC 4x2,5+3x1

Helukabel
Part no.
660897

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 30
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled servo motor cables


for mobile use

Base line for use on SEW drive systems




Technical data

Temperature range
moving -20 C to +60 C
not moving -50 C to +80 C
Bending radius
moving 10 x cable diameter
not moving 3 x cable diameter
Max. acceleration
20 m/s2 for 4 m horizontal traverse path
Bending cycles
5 million for 10x cable diameter
Operating voltage U0/U 600/1000 V
power cores
Operating voltage U 1000 V AC control
cores
Test voltage, power cores 4 kV
Test voltage, control cores 4 kV
Insulation resistance 100 MOhm x km


Approbations
Desina (ISO 23570)
UL/CSA

Cable structure

Power supply cores


Bare copper, extra fine wire conductor
according to DINVDE0295CL.6
high quality PP core insulation
Core identification U/L1/C/L+
V/L2
W/L3/D/L Earth core KVIIR]IPPS[
Signal cores
Copper conductors, bare, fine wire
stranded
High quality PP core insulation
Core identification 1, 2, 3
Cores twisted to triple
Shield, tin-plated copper braiding
Complete shield made of tin-plated
copper braiding
Coverage approx. 85%
PUR outer sheath
Sheath colour orange (RAL 2003)

Application
This high quality pre-assembled motor
connection cable is specially manufactured
for applications with mobile use. The special
PUR outer jacket allows use in many industrial
environments of general machine and plant
construction.


Characteristic

These pre-assembled cables can be produced


in any lengths and also with
customer-specific modifications.


Note

Please observe the installation instructions


for laying cables in cable carriers on Page 36
and the drive or controller manufacturers
information about maximum permitted
cable length.

Helukabel
Designation
motor cable 1991809 PUR 4x1,5
motor cable 1991825 PUR 4x2,5
motor cable 1991841 PUR 4x4
motor cable 1991868 PUR 4x6
motor cable 1991884 PUR 4x10

Helukabel
Part no.
660824
660825
660826
660827
660828


Helukabel
Designation
motor cable 1991906 PUR 4x1,5+3x1
motor cable 1991922 PUR 4x2,5+3x1
motor cable 1991949 PUR 4x4+3x1
motor cable 1991965 PUR 4x6+3x1
motor cable 1991981 PUR 4x10+3x1

Helukabel
Part no.
660829
660830
660831
660832
660833

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 31
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled feedback cables


for fixed laying

Base line for use on SEW drive systems




Technical data

Temperature range
not moving -40 C to +80 C
Bending radius
not moving 20 x cable diameter
Nominal voltage max. 350 V, 300 V
according to UL
Test voltage, core/core 1.5 kV
Test voltage, core/shield 1 kV


Approbations

Cable structure

Power supply cores


Copper conductors, bare
PP core insulation
Core identification colours according to
DIN47100
Complete shield made of tin-plated
copper braiding with drain wire
Coverage approx. 85%
PVC outer jacket
Sheath colour green

Desina (ISO 23570)


UL/CSA

Application
This high quality pre-assembled sensor
connection cable is specially manufactured
for applications with static installation. The
special PVC outer jacket allows use in many
industrial environments of general machine
and plant construction.


Characteristic

Economical alternatives to the cable carrier


compatible cable types which otherwise meet
all requirements of the servo drive
manufacturers. These pre-assembled cables
can be produced in any lengths and also with
customer-specific modifications.


Note

Please observe the drive or controller


manufacturer's information about maximum
permitted cable length.



Helukabel
Designation
feedback cables HF 13324535 PVC 6x2x0,25
feedback extension HF 1995391 PVC 6x2x0,25

Helukabel
Part no.
660834
660835


Helukabel
Designation
feedback cables 1994875 PVC 5x2x0,25
feedback extension 1995421 PVC 5x2x0,25

Helukabel
Part no.
660836
660837

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 32
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled feedback cables


for mobile use

Base line for use on SEW drive systems




Technical data

Temperature range
moving -20 C to +60 C
not moving -50 C to +80 C
Bending radius
moving 10 x cable diameter
not moving 5 x cable diameter
Max. acceleration
20 m/s2
Bending cycles
10 million for 10x cable diameter
Nominal voltage 300 V
Test voltage 1.5 kV


Cable structure

Application

Copper conductors, bare


PP core insulation
TPE inner sheath
Complete shield made of tin-plated
copper braiding
Coverage approx. 80%
PUR outer sheath
Sheath colour green
Core identification colours according to
DIN47100

Characteristic

These pre-assembled cables can be produced


in any lengths and also with
customer-specific modifications.


Note

Approbations

Please observe the installation instructions


for laying cables in cable carriers on Page 36
and the drive or controller manufacturers
information about maximum permitted
cable length.

Desina (ISO 23570)


UL/CSA

Helukabel
Designation
feedback cables HF 13324551 PUR 6x2x0,25
feedback extension HF 1995405 PUR 6x2x0,25

This high quality pre-assembled sensor


connection cable is specially manufactured
for applications with mobile use. The special
PUR outer jacket allows use in many industrial
environments of general machine and plant
construction.


Helukabel
Part no.
660838
660839


Helukabel
Designation
feedback cables 1994875 PVC 5x2x0,25
feedback extension 1995421 PVC 5x2x0,25

Helukabel
Part no.
660840
660841

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 33
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled servo motor cables


for fixed laying

Base line for use on SEW drive systems




Technical data

Temperature range
moving 0 C to +60 C
not moving -20 C to +80 C
Bending radius
moving 20 x cable diameter
not moving 9 x cable diameter
Max. acceleration
2 m/s2
Bending cycles
50,000 for 20x cable diameter
Operating voltage, power supply
cores 600/1000 V
Test voltage, power cores 4 kV
Insulation resistance 20 MOhm x km


Approbations

Desina (ISO 23570)


UL/CSA

Cable structure

Brake motor cable


Power supply cores
Bare copper, extra fine wire conductor
according to DINVDE0295CL.5
high quality PP core insulation
Core identification 1, 2, 3
Earth core K
KVIIR]IPPS[
VIIR]IPPS[
Brake cores
Copper conductors, bare
Core insulation LMKLUYEPMX]44
Core identification black
white
Shielding aluminium/polyester foil,
screened with tin-plated copper wires
Motor cable
Power supply cores
Bare copper, according to IEC60228Cl.6
Core Insulation PVC
Core identification U/L1/C/L+
V/L2
W/L3/D/L Earth core KVIIR]IPPS[
Complete shield made of tin-plated
copper braiding
Coverage approx. 80%
PVC outer jacket
Sheath colour, orange (RAL 2003)

Application
This high quality pre-assembled motor
connection cable is specially manufactured
for applications with static installation. The
special PVC outer jacket allows use in many
industrial environments of general machine
and plant construction.


Characteristic

Economical alternatives to the cable carrier


compatible cable types which otherwise meet
all requirements of the servo drive
manufacturers. These pre-assembled cables
can be produced in any lengths and also with
customer-specific modifications.


Note

Please observe the drive or controller


manufacturer's information about maximum
permitted cable length.


Helukabel
Designation
motor cable 1995502 PVC 4x1,5
motor cable 05904552 PVC 4x2,5

Helukabel
Part no.
660842
660843


Helukabel
Designation
motor cable 13324853 PVC 4x1,5+2x1
motor cable 13332139 PVC 4x2,5+2x1

Helukabel
Part no.
660844
660845

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 34
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled servo motor cables


for mobile use

Base line for use on SEW drive systems




Technical data

Temperature range
moving 0 C to +60 C
not moving -30 C to +80 C
Bending radius
moving 12 x cable diameter
not moving 7 x cable diameter
Max. acceleration
4 m/s2
Bending cycles
10 million for 12x cable diameter
Operating voltage, power supply
cores 600/1000 V
Test voltage, power cores 3 kV
Test voltage, control cores 1.5 kV
Insulation resistance 500 MOhm x km


Approbations
Desina (ISO 23570)
UL/CSA

Cable structure

For brake motor cables


Power supply cores
Copper conductors, bare
Polyolefin polymer core insulation
Core identification 1, 2, 3
Earth core KVIIR]IPPS[
Brake cores
Copper conductors, bare, fine wire
stranded
Core insulation polyester
Core identification black
white
Shielding screened with tin-plated copper
wires
For motor cables
Power supply cores
Copper conductors, bare, fine wire
stranded
Core insulation polyester
Core identification U/L1/C/L+
V/L2
W/L3/D/L Earth core KVIIR]IPPS[
Complete shield made of tin-plated
copper braiding
Coverage approx. 80%
PUR outer sheath
Sheath colour, orange (RAL 2003)

Application
This high quality pre-assembled motor
connection cable is specially manufactured
for applications with mobile use. The special
PUR outer jacket allows use in many industrial
environments of general machine and plant
construction.


Characteristic

These pre-assembled cables can be produced


in any lengths and also with
customer-specific modifications.


Note

Please observe the installation instructions


for laying cables in cable carriers on Page 36
and the drive or controller manufacturers
information about maximum permitted
cable length.

Helukabel
Designation
motor cable 05906245 PUR 4x1,5
motor cable 05906253 PUR 4x2,5

Helukabel
Part no.
660846
660847


Helukabel
Designation
motor cable 13331221 PUR 4x1,5+2x1
motor cable 13332155 PUR 4x2,5+2x1

Helukabel
Part no.
660848
660849

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 35
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled feedback cables


For use on Heidenhain measurement systems


Technical data

Temperature range
-20 C to +70 C
Max. operating voltage 50 V

Cable structure

Application

Tinned copper conductor, fine wire


stranded
PVC/PP core insulation
Shielding
Internal shield: tinned copper winding
External shield: tinned copper winding
PUR outer sheath
Sheath colour black
Structure/colour code
((5x0.14)+4x0.25+2x0.25+1x0.5) ((wh,
bn, gn, ye, gy) bu, bk, rd, rd/bu, wh/bu,
wh/gn, bn/gn, gy/pk)

This pre-assembled sensor cable is suitable


for use on Heiderhain measurement systems
(hand wheels).


Characteristic

These pre-assembled cables can be produced


in any lengths and with customer-specific
modifications.


Note

Please observe the drive or controller


manufacturer's information about maximum
permitted cable length.


Helukabel
Designation
spiral cable 312879 PUR sw

Helukabel
Part no.
660893

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 36
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pre-assembled adapter cables


For use on Heidenhain measurement systems (hand wheels)


Technical data

Temperature range
moving -15 C to +60 C
not moving -30 C to +80 C
Bending radius
moving 15 x cable diameter
not moving 8 x cable diameter
Max. operating voltage 300 V
Test voltage 1.5 kV
Insulation resistance 100 MOhm x km

Cable structure

Application

Tinned copper conductors


SR PVC core insulation
Complete shield made of tin-plated
copper braiding
PVC outer jacket
Sheath colour black
Structure/colour code
internal code for UL/CSA cables bl, bn,
rd, or, ye, gn

This pre-assembled sensor cable is suitable


for use on Heiderhain measurement systems
(hand wheels).


Characteristic

These pre-assembled cables can be produced


in any lengths and with customer-specific
modifications.


Note

Please observe the drive or controller


manufacturer's information about maximum
permitted cable length.


Helukabel
Designation
adapter cables 296466 PVC sw

Helukabel
Part no.
660894

Dimensions and specifications may be changed without prior notice.


The prefabricated cables listed here are not original parts, but accessories manufactured by the company HELUKABEL GmbH. The data, standards and approvals relate solely
to the bulk goods used.

U 37
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Project planning sheet for pre-assembled cables


Description of the pre-assembled cable
Male connector description

Connection diagram

 R Mating face view

 PIN

 R Working side view

Assignment
Core No./
colour

PIN

Connection diagram

Core No./  R Mating face view


colour  R Working side view

Cores not used

Cores not used

 R insulate

 R insulate

 R cut off

 R cut off

Cable outlet

Cable outlet

 R straight

 R straight

 R angled in PIN direction

 R angled in PIN direction

Coding setting

 R in direction

 R in direction

Screen machining
 outer

inner

 R

 R

Coding setting

Screen machining
 outer

inner

cut off

 R

cut off

on case

 R

on case

 R

on PIN

 R

on PIN

 R

implement with core

 R

implement with core

 R insulate outer screen against inner screen

 R insulate outer screen against inner screen

 R connect inner screens

 R connect inner screens

 R insulate inner screens against each other

 R insulate inner screens against each other

 R cut off outer screen, encase with sheath

 R cut off outer screen, encase with sheath

 R screen window

 R screen window

Width

Width

Position

Position

Special features

Special features

U 38
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Project planning sheet for pre-assembled cables


Customer data
Company name
Address

Tel

Post code, Town/City

Fax

Contact

Email

Data for the pre-assembled cable


Designation

Batch sizes/
scale quantities

Annual requirement

Delivery time/
date

Sold by the metre


Designation/
description/design

Usage
conditions

Sheath material

Lengths (n)

Sheath colour

Supplier

Approvals

Supplier
article number

Side A

Side B

R Male connector

R Male connector

Designation/
Description

Designation/
Description

Quality class

Quality class

Supplier

Supplier

Supplier
article number

Supplier
article number

R Machined open end

R Machined open end

Designation/
Description

Designation/
Description

Stripping dimensions/
core lengths

Stripping dimensions/
core lengths

Contacts/
Male connector

Contacts/
Male connector

Supplier

Supplier

Supplier
article number

Supplier
article number

R cut ush

R labelled

R not labelled

R cut ush

Lettering
system

Lettering
system

Supplier

Supplier

Supplier
article number

Supplier
article number

Special
test parameters

Special
test parameters

Packaging

Packaging

R labelled

R not labelled

U 39
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

ROBOFLEX-recycle
The cables with this new sheath material cover all
requirements for very large mechanical stresses
for abrasion, tear resistance, torsion, exing,
exibility and oil resistance. Using for automation
technology, plant and machine construction,
xture construction for handling devices,
welding devices and welding tongs, assembly and
handling devices, machining production, welding
robots and tool machines, blast furnaces and
rolling mills. The completely new feature of this
cable is the weld splatter resistance without the
required cross-linking process.

Our newly developed non-cross-linked


thermoplastic elastomer is fully recyclable.
In contrast to this, the usual, cross-linked,
thermoplastic elastomers cannot be recycled
and put a not insignicant stress on our
environment.
A signicantly longer service life than that of
existing cables on the market, because it can be
used in highly exible applications, for example
on robots (torsion) and in drag chains (dynamic
load).

U 40
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX-recycle M12 femal one end pre-assembled 3-, 4- and 5-pin




Technical data

Approval:
UL/cUL approved
Production
in accordance with VDE standards
Temperature range:
fixed installation -40 C to +120 C
flexible -30 C to +120 C
Nominal voltage:
300 V
Test voltage:
2000V
Minimum bending radius:
approx. 7.5 x cable diameter (for flexible
installation)
Traversing speed:
max. 3.3 m/s for 5 m of horizontal traverse
path length
Acceleration:
max. 5 m/s
Flexing and torsion cycles:
min. 10 million.
Torsional stress:
+/- 360 /m

Cable structure

Properties

Bare copper litz wire, 42 x 0.10 mm


Core insulation polyester, black, blue,
brown
Cores stranded in layers
Sheath, special mix
weld splatter resistant, dull, low adhesion,
flame retardant and self-extinguishing (as
per VDE 0472 Part 804 Test method B, IEC
60332-1)
Sheath colour: black
Assembly (3-pin)
colour of cores brown, blue, black
AD 5,2 +/-0,2 mm
Assembly (4-pin)
colour of cores brown, blue, black, white
AD 5,5 +/-0,2 mm
Assembly (5-pin)
colour of cores brown, blue, black, white,
grey
AD 6,0 +/-0,2 mm

very good resistance to oil


as per VDE 0473 Part 811-2-1
good resistance to acids, alkalis and
solvents
not cross-linked
weld splatter resistant
recyclable
halogen-free
Silicone and cadmium-free
Free of substances harmful to paint
adhesion Substances
very high mechanical load capacity
abrasion resistant
wear-resistant
Highly flexible
UV-resistant
ROHS conformant
CE conformant


Note

* Design for the standard 2 LEDs in the


colours: yellow, green.
3 LEDs in the colours: white, yellow, green available upon request.
** Sensor cable ROBOFLEX-recycle M12 socket,
angled, preassembled on one side, 5 pins.
Available on request.
IP67
A-coded

socket with LED


Part no.
670742
670743
670744
670745
670746
670747
670748
670749
671543
671544
671546
671547
671548
671557
671550
671551
671552
671553
671473
671474
671476
671477
671478

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34

Length
m

Plug type

1,5
3,0
5,0
10,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0

socket angled with 2 LED


socket angled with 2 LED
socket angled with 2 LED
socket angled with 2 LED
socket angled with 2 LED
socket angled with 2 LED
socket angled with 2 LED
socket angled with 2 LED
socket straight with LED
socket straight with LED
socket straight with LED
socket straight with LED
socket straight with LED
socket straight with LED
socket straight with LED
socket straight with LED
socket straight with LED
socket straight with LED
socket straight with LED
socket straight with LED
socket straight with LED
socket straight with LED
socket straight with LED

Cop.
weight
kg / 1000 pcs.
14,7
29,4
49,0
98,0
19,7
39,3
65,5
131,0
9,8
14,7
29,4
49,0
98,0
13,1
19,7
39,3
65,5
131,0
16,5
24,8
49,5
82,5
165,0

Continuation

U 41
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX-recycle M12 femal one end pre-assembled 3-, 4- and 5-pin


socket without LED
Part no.
670722
670723
670724
670725
670738
670739
670740
670741
671438
671439
671440
671441
670718
670719
671720
670721
670734
670735
670736
670737
671434
671435
671436
671437

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34

Length
m

Plug type

1,5
3,0
5,0
10,0
1,5
3,0
5,0
10,0
1,5
3,0
5,0
10,0
1,5
3,0
5,0
10,0
1,5
3,0
5,0
10,0
1,5
3,0
5,0
10,0

socket angled without LED


socket angled without LED
socket angled without LED
socket angled without LED
socket angled without LED
socket angled without LED
socket angled without LED
socket angled without LED
socket angled without LED
socket angled without LED
socket angled without LED
socket angled without LED
socket straight without LED
socket straight without LED
socket straight without LED
socket straight without LED
socket straight without LED
socket straight without LED
socket straight without LED
socket straight without LED
socket straight without LED
socket straight without LED
socket straight without LED
socket straight without LED

Cop.
weight
kg / 1000 pcs.
14,7
29,4
49,0
98,0
19,7
39,3
65,5
131,0
24,8
49,5
82,5
165,0
14,7
29,4
49,0
98,0
19,7
39,3
65,5
131,0
24,8
49,5
82,5
165,0

Dimensions and specifications may be changed without prior notice.

U 42
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX-recycle M12 sensor cable 4-pin + PE one end pre-assembled




Technical data

Approval:
UL/cUL approved
Production
in accordance with VDE standards
Temperature range:
fixed installation -40 C to +120 C
flexible -30 C to +120 C
Nominal voltage:
300 V
Test voltage:
2000V
Minimum bending radius:
approx. 7.5 x cable diameter (for flexible
installation)
Traversing speed:
max. 3.3 m/s for 5 m of horizontal traverse
path length
Acceleration:
max. 5 m/s
Flexing and torsion cycles:
min. 10 million.
Torsional stress:
+/- 360 /m

Cable structure

Properties

Bare copper litz wire, 42 x 0.10 mm


Core insulation polyester, black, blue,
brown
Cores stranded in layers
Sheath, special mix
weld splatter resistant, dull, low adhesion,
flame retardant and self-extinguishing (as
per VDE 0472 Part 804 Test method B, IEC
60332-1)
Sheath colour: black
Assembly (5-pin)
colour of cores brown, blue, black, white,
green/yellow
AD 6,0 +/-0,2 mm

very good resistance to oil


as per VDE 0473 Part 811-2-1
good resistance to acids, alkalis and
solvents
not cross-linked
weld splatter resistant
recyclable
halogen-free
Silicone and cadmium-free
Free of substances harmful to paint
adhesion Substances
very high mechanical load capacity
abrasion resistant
wear-resistant
Highly flexible
UV-resistant
ROHS conformant
CE conformant


Note

IP67
A-coded

socket one end pre-assembled with LED


Part no.
672393
672394
672396
672397
672399
672403
672404
672406
672407
672409
672343
672344
672346
672347
672349
672353
672354
672356
672357
672359

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34

Length
m

Plug type

1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0

plug, straight
plug, straight
plug, straight
plug, straight
plug, straight
plug, angled
plug, angled
plug, angled
plug, angled
plug, angled
socket straight
socket straight
socket straight
socket straight
socket straight
socket angled
socket angled
socket angled
socket angled
socket angled

Cop.
weight
kg / 1000 pcs.
16,5
24,8
49,5
82,5
165,0
16,5
24,8
49,5
82,5
165,0
16,5
24,8
49,5
82,5
165,0
16,5
24,8
49,5
82,5
165,0

socket one end pre-assembled, 3 LED (gn, rd, ye)


Part no.
672413
672414
672416
672417
672419
672363
672364
672366
672367
672369

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34

Length
m

Plug type

1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0

socket straight with LED


socket straight with LED
socket straight with LED
socket straight with LED
socket straight with LED
socket angled with LED
socket angled with LED
socket angled with LED
socket angled with LED
socket angled with LED

Cop.
weight
kg / 1000 pcs.
16,5
24,8
49,5
82,5
165,0
16,5
24,8
49,5
82,5
165,0

Dimensions and specifications may be changed without prior notice.

U 43
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX-recycle M12 both ends pre-assembled




Technical data

Approval:
UL/cUL approved
Production
in accordance with VDE standards
Temperature range:
fixed installation -40 C to +120 C
flexible -30 C to +120 C
Nominal voltage:
300 V
Test voltage:
2000V
Minimum bending radius:
approx. 7.5 x cable diameter (for flexible
installation)
Traversing speed:
max. 3.3 m/s for 5 m of horizontal traverse
path length
Acceleration:
max. 5 m/s
Flexing and torsion cycles:
min. 10 million.
Torsional stress:
+/- 360 /m

Cable structure

Properties

Bare copper litz wire, 42 x 0.10 mm


Core insulation polyester, black, blue,
brown
Cores stranded in layers
Sheath, special mix
weld splatter resistant, dull, low adhesion,
flame retardant and self-extinguishing (as
per VDE 0472 Part 804 Test method B, IEC
60332-1)
Sheath colour: black
Assembly (3-pin)
colour in cores brown, blue, black
AD 5,2 +/-0,2 mm
Assembly (4-pin)
colour of cores brown, blue, black, white
AD 5,5 +/-0,2 mm
Assembly (5-pin)
colour of cores brown, blue, black, white,
grey
AD 6,0 +/-0,2 mm

very good resistance to oil


as per VDE 0473 Part 811-2-1
good resistance to acids, alkalis and
solvents
not cross-linked
weld splatter resistant
recyclable
halogen-free
Silicone and cadmium-free
Free of substances harmful to paint
adhesion Substances
very high mechanical load capacity
abrasion resistant
wear-resistant
Highly flexible
UV-resistant
ROHS conformant
CE conformant


Note

*Design for the standard 2 LEDs in the


colours: yellow, green.
3 LEDs in the colours: white, yellow ,green available upon request.
** Sensor cable ROBOFLEX-recycle M12 plug,
straight and socket, angled, pre-assembled
on both side, 5-pin. Available on request.
IP67
A-coded

plug straight / socket angled with LED


Part no.
670866
670802
670803
670804
670805
670867
670814
670815
670816
670817

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34

Length
m

Plug type

1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0

plug straight / socket, angled with 2 LED


plug straight / socket, angled with 2 LED
plug straight / socket, angled with 2 LED
plug straight / socket, angled with 2 LED
plug straight / socket, angled with 2 LED
plug straight / socket, angled with 2 LED
plug straight / socket, angled with 2 LED
plug straight / socket, angled with 2 LED
plug straight / socket, angled with 2 LED
plug straight / socket, angled with 2 LED

Cop.
weight
kg / 1000 pcs.
9,8
14,7
29,4
49,0
98,0
13,1
19,7
39,3
65,5
131,0

plug straight / socket straight without LED


Part no.
671341
670750
670751
670752
670753
670771
670774
670775
670776
670777
671493
671494
671496
671497
671499

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34

Length
m

Plug type

1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0

plug straight / socket straight without LED


plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED

Cop.
weight
kg / 1000 pcs.
9,8
14,7
29,4
49,0
98,0
13,1
19,7
39,3
65,5
131,0
16,5
24,8
49,5
82,5
165,0

Continuation

U 44
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX-recycle M12 both ends pre-assembled


plug straight / socket angled without LED
Part no.
670757
670758
670759
670760
670761
670781
670782
670783
670784
670785
671483
671484
671486
671487
671489

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34

Length
m

Plug type

1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0

plug straight / socket angled without LED


plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED

Cop.
weight
kg / 1000 pcs.
9,8
14,7
29,4
49,0
98,0
13,1
19,7
39,3
65,5
131,0
16,5
24,8
49,5
82,5
165,0

plug angled / socket angled without LED


Part no.
670766
670767
670768
670769
670790
670791
670792
670793
671533
671534
671536
671537

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34

Length
m

Plug type

1,5
3,0
5,0
10,0
1,5
3,0
5,0
10,0
1,5
3,0
5,0
10,0

plug angled / socket angled without LED


plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED

Cop.
weight
kg / 1000 pcs.
14,7
29,4
49,0
98,0
19,7
39,3
65,5
131,0
24,8
49,5
82,5
165,0

Dimensions and specifications may be changed without prior notice.

U 45
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX-recycle M12 5-pin + PE both ends pre-assembled




Technical data

Approval:
UL/cUL approved
Production
in accordance with VDE standards
Temperature range:
fixed installation -40 C to +120 C
flexible -30 C to +120 C
Nominal voltage:
300 V
Test voltage:
2000V
Minimum bending radius:
approx. 7.5 x cable diameter (for flexible
installation)
Traversing speed:
max. 3.3 m/s for 5 m of horizontal traverse
path length
Acceleration:
max. 5 m/s
Flexing and torsion cycles:
min. 10 million.
Torsional stress:
+/- 360 /m

Cable structure

Properties

Bare copper litz wire, 42 x 0.10 mm


Core insulation polyester, black, blue,
brown
Cores stranded in layers
Sheath, special mix
weld splatter resistant, dull, low adhesion,
flame retardant and self-extinguishing (as
per VDE 0472 Part 804 Test method B, IEC
60332-1)
Sheath colour: black
Assembly (5-pin)
colour of cores brown, blue, black, white,
green/yellow
AD 6,0 +/-0,2 mm

very good resistance to oil


as per VDE 0473 Part 811-2-1
good resistance to acids, alkalis and
solvents
not cross-linked
weld splatter resistant
recyclable
halogen-free
Silicone and cadmium-free
Free of substances harmful to paint
adhesion Substances
very high mechanical load capacity
abrasion resistant
wear-resistant
Highly flexible
UV-resistant
ROHS conformant
CE conformant


Note

IP67
A-codiert

both ends pre-assembled without LED


Part no.
672303
672304
672306
672307
672309
672443
672444
672446
672447
672449
672313
672314
672316
672317
672319

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34

Length
m

Plug type

1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0

plug straight / socket straight


plug straight / socket straight
plug straight / socket straight
plug straight / socket straight
plug straight / socket straight
plug angled / socket angled
plug angled / socket angled
plug angled / socket angled
plug angled / socket angled
plug angled / socket angled
plug straight / socket angled
plug straight / socket angled
plug straight / socket angled
plug straight / socket angled
plug straight / socket angled

Cop.
weight
kg / 1000 pcs.
16,5
24,8
49,5
82,5
165,0
16,5
24,8
49,5
82,5
165,0
16,5
24,8
49,5
82,5
165,0

both ends pre-assembled, 3 LED (gn, rd, ye)


Part no.
672333
672334
672336
672337
672339
672373
672374
672376
672377
672379
672323
672324
672326
672327
672329

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34

Length
m

Plug type

1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0

plug straight / socket straight


plug straight / socket straight
plug straight / socket straight
plug straight / socket straight
plug straight / socket straight
socket angled / socket angled
socket angled / socket angled
socket angled / socket angled
socket angled / socket angled
socket angled / socket angled
plug straight / socket angled
plug straight / socket angled
plug straight / socket angled
plug straight / socket angled
plug straight / socket angled

Cop.
weight
kg / 1000 pcs.
16,5
24,8
49,5
82,5
165,0
16,5
24,8
49,5
82,5
165,0
16,5
24,8
49,5
82,5
165,0

Dimensions and specifications may be changed without prior notice.

U 46
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX-recycle M12 plug straight or angled, pre-assembled on one end,


3-pin, 4-pin and 5-pin


Technical data

Approval:
UL/cUL approved
Production
in accordance with VDE standards
Temperature range:
fixed installation -40 C to +120 C
flexible -30 C to +120 C
Nominal voltage:
300 V
Test voltage:
2000V
Minimum bending radius:
approx. 7.5 x cable diameter (for flexible
installation)
Traversing speed:
max. 3.3 m/s for 5 m of horizontal traverse
path length
Acceleration:
max. 5 m/s
Flexing and torsion cycles:
min. 10 million.
Torsional stress:
+/- 360 /m

Cable structure

Assembly (3-pin)
Bare copper litz wire, 42 x 0.10 mm
Core insulation polyester, black, blue,
brown
Cores stranded in layers
Sheath, special mix
weld splatter resistant, dull, low adhesion,
flame retardant and self-extinguishing (as
per VDE 0472 Part 804 Test method B, IEC
60332-1)
Sheath colour: black
Outer diameter 4.9 +/-0.2 mm
Assembly (4-pin)
Bare copper litz wire, 42 x 0.10 mm
Core insulation polyester, black, brown,
white, blue
Cores stranded in layers
Sheath, special mix
weld splatter resistant, dull, low adhesion,
flame retardant and self-extinguishing (as
per VDE 0472 Part 804 Test method B, IEC
60332-1)
Sheath colour: black
Outer diameter 4.9 +/-0.2 mm


Properties
very good resistance to oil
as per VDE 0473 Part 811-2-1
good resistance to acids, alkalis and
solvents
not cross-linked
weld splatter resistant
recyclable
halogen-free
Silicone and cadmium-free
Free of substances harmful to paint
adhesion Substances
very high mechanical load capacity
abrasion resistant
wear-resistant
Highly flexible
UV-resistant
ROHS conformant
CE conformant


Note

IP67
A-coded


Part no.
670710
670711
670712
670713
670714
670715
670716
670717
670726
670727
670728
670729
670730
670731
670732
670733
671426
671427
671428
671429
671430
671431
671432
671433

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34

Length
m

Plug type

1,5
3,0
5,0
10,0
1,5
3,0
5,0
10,0
1,5
3,0
5,0
10,0
1,5
3,0
5,0
10,0
1,5
3,0
5,0
10,0
1,5
3,0
5,0
10,0

plug, straight
plug, straight
plug, straight
plug, straight
plug, angled
plug, angled
plug, angled
plug, angled
plug, straight
plug, straight
plug, straight
plug, straight
plug, angled
plug, angled
plug, angled
plug, angled
plug, straight
plug, straight
plug, straight
plug, straight
plug, angled
plug, angled
plug, angled
plug, angled

Cop.
weight
kg / 1000 pcs.
14,7
29,4
49,0
98,0
14,7
29,4
49,0
98,0
19,7
39,3
65,5
131,0
19,7
39,3
65,5
131,0
24,8
49,5
82,5
165,0
24,8
49,5
82,5
165,0

Dimensions and specifications may be changed without prior notice.

U 47
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX-recycle M8 femal one end pre-assembled




Technical data

Cable structure

Properties

Approval:
UL/cUL approved
Production
in accordance with VDE standards
Temperature range:
fixed installation -40 C to +120 C
flexible -30 C to +120 C
Nominal voltage:
300 V
Test voltage:
2000V
Minimum bending radius:
approx. 7.5 x cable diameter (for flexible
installation)
Traversing speed:
max. 3.3 m/s for 5 m of horizontal traverse
path length
Acceleration:
max. 5 m/s
Flexing and torsion cycles:
min. 10 million.
Torsional stress:
+/- 360 /m

Bare copper litz wire, 42 x 0.10 mm


Core insulation polyester, black, blue,
brown
Cores stranded in layers
Sheath, special mix
weld splatter resistant, dull, low adhesion,
flame retardant and self-extinguishing (as
per VDE 0472 Part 804 Test method B, IEC
60332-1)
Sheath colour: black
Assembly (3-pin)
colour of cores brown, blue, black
AD 5,2 +/-0,2 mm
Assembly (4-pin)
colour of cores brown, blue, black, white
AD 5,5 +/-0,2 mm

very good resistance to oil


as per VDE 0473 Part 811-2-1
good resistance to acids, alkalis and
solvents
not cross-linked
weld splatter resistant
recyclable
halogen-free
Silicone and cadmium-free
Free of substances harmful to paint
adhesion Substances
very high mechanical load capacity
abrasion resistant
wear-resistant
Highly flexible
UV-resistant
ROHS conformant
CE conformant


Note

IP67
A-coded

socket angled with 2 LED


Part no.
670672
670673
670674
670675
670688
670689
670690
670691

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34

Length
m

Plug type

1,5
3,0
5,0
10,0
1,5
3,0
5,0
10,0

socket angled with 2 LED


socket angled with 2 LED
socket angled with 2 LED
socket angled with 2 LED
socket angled with 2 LED
socket angled with 2 LED
socket angled with 2 LED
socket angled with 2 LED

Length
m

Plug type

1,5
3,0
5,0
10,0
1,5
3,0
5,0
10,0
1,5
3,0
5,0
10,0
1,5
3,0
5,0
10,0

socket straight without LED


socket straight without LED
socket straight without LED
socket straight without LED
socket angled without LED
socket angled without LED
socket angled without LED
socket angled without LED
socket straight without LED
socket straight without LED
socket straight without LED
socket straight without LED
socket angled without LED
socket angled without LED
socket angled without LED
socket angled without LED

Cop.
weight
kg / 1000 pcs.
14,7
29,4
49,0
98,0
19,7
39,3
65,5
131,0

socket straight without LED


Part no.
670668
670669
670670
670671
670656
670657
670658
670659
670684
670685
670686
670687
670693
670694
670695
670696

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34

Cop.
weight
kg / 1000 pcs.
14,7
29,4
49,0
98,0
14,7
29,4
49,0
98,0
19,7
39,3
65,5
131,0
19,7
39,3
65,5
131,0

Dimensions and specifications may be changed without prior notice.

U 48
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX-recycle M8 pre-assembled on both ends




Technical data

Cable structure

Properties

Approval:
UL/cUL approved
Production
in accordance with VDE standards
Temperature range:
fixed installation -40 C to +120 C
flexible -30 C to +120 C
Nominal voltage:
300 V
Test voltage:
2000V
Minimum bending radius:
approx. 7.5 x cable diameter (for flexible
installation)
Traversing speed:
max. 3.3 m/s for 5 m of horizontal traverse
path length
Acceleration:
max. 5 m/s
Flexing and torsion cycles:
min. 10 million.
Torsional stress:
+/- 360 /m

Assembly (3-pin)
Bare copper litz wire, 42 x 0.10 mm
Core insulation polyester, black, blue,
brown
Cores stranded in layers
Sheath, special mix
weld splatter resistant, dull, low adhesion,
flame retardant and self-extinguishing (as
per VDE 0472 Part 804 Test method B, IEC
60332-1)
Sheath colour: black
Outer diameter 4.9 +/-0.2 mm
Assembly (4-pin)
Bare copper litz wire, 42 x 0.10 mm
Core insulation polyester, black, brown,
white, blue
Cores stranded in layers
Sheath, special mix
weld splatter resistant, dull, low adhesion,
flame retardant and self-extinguishing (as
per VDE 0472 Part 804 Test method B, IEC
60332-1)
Sheath colour: black
Outer diameter 4.9 +/-0.2 mm

very good resistance to oil


as per VDE 0473 Part 811-2-1
good resistance to acids, alkalis and
solvents
not cross-linked
weld splatter resistant
recyclable
halogen-free
Silicone and cadmium-free
Free of substances harmful to paint
adhesion Substances
very high mechanical load capacity
abrasion resistant
wear-resistant
Highly flexible
UV-resistant
ROHS conformant
CE conformant


Note

* Design for the standard 2 LEDs in the


colours: yellow, green.
IP67, A-coded

plug straight / socket angled with 2 LED


Part no.
670849
670850
670851
670852
670853
670861
670862
670863
670864
670865

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34

Length
m

Plug type

1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0

plug straight / socket, angled with 2 LED


plug straight / socket, angled with 2 LED
plug straight / socket, angled with 2 LED
plug straight / socket, angled with 2 LED
plug straight / socket, angled with 2 LED
plug straight / socket, angled with 2 LED
plug straight / socket, angled with 2 LED
plug straight / socket, angled with 2 LED
plug straight / socket, angled with 2 LED
plug straight / socket, angled with 2 LED

Cop.
weight
kg / 1000 pcs.
9,8
14,7
29,4
49,0
98,0
13,1
19,7
39,3
65,5
131,0

plug straight / socket straight without LED


Part no.
671356
670822
670823
670824
670825
671351
670834
670835
670836
670837

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34

Length
m

Plug type

1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0

plug straight / socket straight without LED


plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED

Cop.
weight
kg / 1000 pcs.
9,8
14,7
29,4
49,0
98,0
13,1
19,7
39,3
65,5
131,0

Continuation

U 49
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX-recycle M8 pre-assembled on both ends


plug straight / socket angled without LED
Part no.
671332
670826
670827
670828
670829
671333
670838
670839
670840
670841

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34

Length
m

Plug type

1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0

plug straight / socket angled without LED


plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED

Cop.
weight
kg / 1000 pcs.
9,8
14,7
29,4
49,0
98,0
13,1
19,7
39,3
65,5
131,0

plug angled / socket angled without LED


Part no.
671334
670830
670831
670832
670833
671335
670842
670843
670844
670845

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34

Length
m

Plug type

1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0

plug angled / socket angled without LED


plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED

Cop.
weight
kg / 1000 pcs.
9,8
14,7
29,4
49,0
98,0
13,1
19,7
39,3
65,5
131,0

Dimensions and specifications may be changed without prior notice.

Cable Glands
Cable glands for standard applications
Plastic Glands
Cable Glands of Brass
Accessories
Cable glands for special application conditions
for electromagnetic compatibility EMC
for rugged applications and special chemical resistance
for high temperature use
for explosive areas
for special mounting conditions
for special pressure conditions

You can nd cable glands in our catalogue Cable Accessories.

U 50
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX-recycle M8 plug, straight or angled, pre-assembled on one side,


3-pin and 4-pin


Technical data

Cable structure

Properties

Approval:
UL/cUL approved
Production
in accordance with VDE standards
Temperature range:
fixed installation -40 C to +120 C
flexible -30 C to +120 C
Nominal voltage:
300 V
Test voltage:
2000V
Minimum bending radius:
approx. 7.5 x cable diameter (for flexible
installation)
Traversing speed:
max. 3.3 m/s for 5 m of horizontal traverse
path length
Acceleration:
max. 5 m/s
Flexing and torsion cycles:
min. 10 million.
Torsional stress:
+/- 360 /m

Bare copper litz wire, 42 x 0.10 mm


Core insulation polyester, black, blue,
brown
Cores stranded in layers
Sheath, special mix
weld splatter resistant, dull, low adhesion,
flame retardant and self-extinguishing (as
per VDE 0472 Part 804 Test method B, IEC
60332-1)
Sheath colour: black
Assembly (3-pin)
colour of cores brown, blue, black
AD 5,2 +/-0,2 mm
Assembly (4-pin)
colour of cores brown, blue, black, white
AD 5,5 +/-0,2 mm

very good resistance to oil


as per VDE 0473 Part 811-2-1
good resistance to acids, alkalis and
solvents
not cross-linked
weld splatter resistant
recyclable
halogen-free
Silicone and cadmium-free
Free of substances harmful to paint
adhesion Substances
very high mechanical load capacity
abrasion resistant
wear-resistant
Highly flexible
UV-resistant
ROHS conformant
CE conformant


Note

IP67
A-coded


Part no.
670660
670661
670662
670663
670664
670665
670666
670667
670676
670677
670678
670679
670680
670681
670682
670683

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34

Length
m

Plug type

1,5
3,0
5,0
10,0
1,5
3,0
5,0
10,0
1,5
3,0
5,0
10,0
1,5
3,0
5,0
10,0

plug, straight
plug, straight
plug, straight
plug, straight
plug, angled
plug, angled
plug, angled
plug, angled
plug, straight
plug, straight
plug, straight
plug, straight
plug, angled
plug, angled
plug, angled
plug, angled

Cop.
weight
kg / 1000 pcs.
14,7
29,4
49,0
98,0
14,7
29,4
29,4
98,0
19,7
39,3
65,5
131,0
19,7
39,3
65,5
131,0

Dimensions and specifications may be changed without prior notice.

U 51
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX-recycle M12 sensor cable screened one end pre-assembled




Technical data

Approval:
UL/cUL approved
Production
in accordance with VDE standards
Temperature range:
fixed installation -40 C to +120 C
flexible -30 C to +120 C
Nominal voltage:
300 V
Test voltage:
2000V
Minimum bending radius:
approx. 7.5 x cable diameter (for flexible
installation)
Traversing speed:
max. 3.3 m/s for 5 m of horizontal traverse
path length
Acceleration:
max. 5 m/s
Flexing and torsion cycles:
min. 10 million.
Torsional stress:
+/- 360 /m

Cable structure

Properties

Bare copperstranded wire, 42 x 0.10 mm


Cores stranded in layers
Polyester foil taping
Screening of tinned copper braid, coverage
approx. 85%, D-screen for robot
applications
Special compound sheath, weld-splatter
resistant, recyclable, matt, low-adhesion,
flame retardant and self-extinguishing (in
accordance with VDE0472 Part804 Test
Method B, IEC60332-1)
Sheath colour: black
Assembly (3-pin)
Core insulation polyester, black,
brown,blue, black
Outer diameter5,2 +/-0.2 mm
Assembly (4-pin)
Core insulation polyester,brown,blue,
black, white
Outer diameter 5.5 +/-0.2 mm
Assembly (5-pin)
Core insulation polyester,brown,blue,
black, white, green
Outer diameter 4.9 +/-0.2 mm

very good resistance to oil


as per VDE 0473 Part 811-2-1
good resistance to acids, alkalis and
solvents
not cross-linked
weld splatter resistant
recyclable
halogen-free
Silicone and cadmium-free
Free of substances harmful to paint
adhesion Substances
very high mechanical load capacity
abrasion resistant
wear-resistant
Highly flexible
UV-resistant
ROHS conformant
CE conformant


Note

IP67
A-coded

plug straight pre-assembled


Part no.
671893
671894
671896
671897
671899
671903
671904
671906
671907
671909
671913
671914
671916
671917
671919
671923
671924
671926
671927
671929
671933
671934
671936
671937
671939
671943
671944
671946
671947
671949

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34

Length
m

Plug type

1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0

plug, straight
plug, straight
plug, straight
plug, straight
plug, straight
plug, angled
plug, angled
plug, angled
plug, angled
plug, angled
plug, straight
plug, straight
plug, straight
plug, straight
plug, straight
plug, angled
plug, angled
plug, angled
plug, angled
plug, angled
plug, straight
plug, straight
plug, straight
plug, straight
plug, straight
plug, angled
plug, angled
plug, angled
plug, angled
plug, angled

Cop.
weight
kg / 1000 pcs.
19,6
29,4
58,8
98,0
196,0
19,6
29,4
58,8
98,0
196,0
24,2
36,3
72,6
121,0
242,0
24,2
36,3
72,6
121,0
242,0
30,0
45,0
90,0
150,0
300,0
30,0
45,0
90,0
150,0
300,0

Continuation

U 52
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX-recycle M12 sensor cable screened one end pre-assembled


socket one end pre-assembled
Part no.
671873
671874
671876
671877
671879
671883
671884
671886
671887
671889
671833
671834
671836
671837
671839
671843
671844
671846
671847
671849
671854
671850
671851
671852
671853
671859
671855
671856
671857
671858

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34

Length
m

Plug type

1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0

socket straight
socket straight
socket straight
socket straight
socket straight
socket angled
socket angled
socket angled
socket angled
socket angled
socket straight
socket straight
socket straight
socket straight
socket straight
socket angled
socket angled
socket angled
socket angled
socket angled
socket straight
socket straight
socket straight
socket straight
socket straight
socket angled
socket angled
socket angled
socket angled
socket angled

Cop.
weight
kg / 1000 pcs.
19,6
29,4
58,8
98,0
196,0
19,6
29,4
58,8
98,0
196,0
24,2
36,3
72,6
121,0
242,0
24,2
36,3
72,6
121,0
242,0
30,0
45,0
90,0
150,0
300,0
30,0
45,0
90,0
150,0
300,0

Dimensions and specifications may be changed without prior notice.

U 53
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX-recycle M12 sensor cable screened both ends pre-assembled




Technical data

Approval:
UL/cUL approved
Production
in accordance with VDE standards
Temperature range:
fixed installation -40 C to +120 C
flexible -30 C to +120 C
Nominal voltage:
300 V
Test voltage:
2000V
Minimum bending radius:
approx. 7.5 x cable diameter (for flexible
installation)
Traversing speed:
max. 3.3 m/s for 5 m of horizontal traverse
path length
Acceleration:
max. 5 m/s
Flexing and torsion cycles:
min. 10 million.
Torsional stress:
+/- 360 /m

Cable structure

Properties

Bare copperstranded wire, 42 x 0.10 mm


Cores stranded in layers
Polyester foil taping
Screening of tinned copper braid, coverage
approx. 85%, D-screen for robot
applications
Special compound sheath, weld-splatter
resistant, recyclable, matt, low-adhesion,
flame retardant and self-extinguishing (in
accordance with VDE0472 Part804 Test
Method B, IEC60332-1)
Sheath colour: black
Assembly (3-pin)
Core insulation polyester, black,
brown,blue, black
Outer diameter5,2 +/-0.2 mm
Assembly (4-pin)
Core insulation polyester,brown,blue,
black, white
Outer diameter 5.5 +/-0.2 mm
Assembly (5-pin)
Core insulation polyester,brown,blue,
black, white, green
Outer diameter 4.9 +/-0.2 mm

very good resistance to oil


as per VDE 0473 Part 811-2-1
good resistance to acids, alkalis and
solvents
not cross-linked
weld splatter resistant
recyclable
halogen-free
Silicone and cadmium-free
Free of substances harmful to paint
adhesion Substances
very high mechanical load capacity
abrasion resistant
wear-resistant
Highly flexible
UV-resistant
ROHS conformant
CE conformant


Note

IP67
A-coded

plug / socket without LED


Part no.
671953
671954
671956
671957
671759
671963
671964
671966
671967
671969
671973
671974
671976
671977
671979
671983
671984
671986
671988
671989
671993
671994
671996
671997
671999
672003
672004
672006
672007
672009
672013
672014
672016
672017
672019

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34
ROBOFLEX-recycle  3x0,34

Length
m

Plug type

1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0
1,5
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0

plug straight / socket straight without LED


plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket straight without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug straight / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED

Cop.
weight
kg / 1000 pcs.
19,6
29,4
58,8
98,0
196,0
24,2
36,3
72,6
121,0
242,0
30,0
45,0
90,0
150,0
300,0
19,6
29,4
58,8
98,0
196,0
24,2
36,3
72,6
121,0
242,0
30,0
45,0
90,0
150,0
300,0
19,6
29,4
58,8
98,0
196,0

Continuation

U 54
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX-recycle M12 sensor cable screened both ends pre-assembled


plug / socket without LED
Part no.
672023
672024
672026
672027
672029
672033
672034
672036
672037
672039

Cable type /
cross-sec.
mm
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  4x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34
ROBOFLEX-recycle  5x0,34

Length
m

Plug type

1,0
1,5
3,0
5,0
10,0
1,0
1,5
3,0
5,0
10,0

plug angled / socket angled without LED


plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED
plug angled / socket angled without LED

Cop.
weight
kg / 1000 pcs.
24,2
36,3
72,6
121,0
242,0
30,0
45,0
90,0
150,0
300,0

Dimensions and specifications may be changed without prior notice.

Conduits
Corrugated tubes
for standard applications
for lager sizes
scissile corrugated tubes
conduit glands
High exible conduits
plastic conduits with spiral spring
metal conduits
conduits glands
Conduit for heavy mechanical duty
metal conduits with plastic sheat
plastic conduits
conduits glands for metal conduits

You can nd conduits in our catalogue Cable Accessories.

U 55
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX-recycle Twin cables M12 to M12




Technical data

Cable structure

Properties

Approval:
UL/cUL approved
Production
in accordance with VDE standards
Temperature range:
fixed installation -40 C to +120 C
flexible -30 C to +120 C
Nominal voltage:
300 V
Test voltage:
2000V
Minimum bending radius:
approx. 7.5 x cable diameter (for flexible
installation)
Traversing speed:
max. 3.3 m/s for 5 m of horizontal traverse
path length
Acceleration:
max. 5 m/s
Flexing and torsion cycles:
min. 10 million.
Torsional stress:
+/- 360 /m

Assembly (3-pin)
Bare copper litz wire, 42 x 0.10 mm
Core insulation polyester, black, blue,
brown
Cores stranded in layers
Sheath, special mix
weld splatter resistant, dull, low adhesion,
flame retardant and self-extinguishing (as
per VDE 0472 Part 804 Test method B, IEC
60332-1)
Sheath colour: black
Outer diameter 4.9 +/-0.2 mm
Assembly (4-pin)
Bare copper litz wire, 42 x 0.10 mm
Core insulation polyester, black, brown,
white, blue
Cores stranded in layers
Sheath, special mix
weld splatter resistant, dull, low adhesion,
flame retardant and self-extinguishing (as
per VDE 0472 Part 804 Test method B, IEC
60332-1)
Sheath colour: black
Outer diameter 4.9 +/-0.2 mm

very good resistance to oil


as per VDE 0473 Part 811-2-1
good resistance to acids, alkalis and
solvents
not cross-linked
weld splatter resistant
recyclable
halogen-free
Silicone and cadmium-free
Free of substances harmful to paint
adhesion Substances
very high mechanical load capacity
abrasion resistant
wear-resistant
Highly flexible
UV-resistant
ROHS conformant
CE conformant


Note

* Twin cables with sensor cable ROBOFLEX


recycle M12 to M8 and other configurations
and lengths - available on request.

Dimensions and specifications may be changed without prior notice.

U 56
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ROBOFLEX-recycle Twin cables M12 to M12




Technical data

Cable structure

Properties

Approval:
UL/cUL approved
Production
in accordance with VDE standards
Temperature range:
fixed installation -40 C to +120 C
flexible -30 C to +120 C
Nominal voltage:
300 V
Test voltage:
2000V
Minimum bending radius:
approx. 7.5 x cable diameter (for flexible
installation)
Traversing speed:
max. 3.3 m/s for 5 m of horizontal traverse
path length
Acceleration:
max. 5 m/s
Flexing and torsion cycles:
min. 10 million.
Torsional stress:
+/- 360 /m

Assembly (3-pin)
Bare copper litz wire, 42 x 0.10 mm
Core insulation polyester, black, blue,
brown
Cores stranded in layers
Sheath, special mix
weld splatter resistant, dull, low adhesion,
flame retardant and self-extinguishing (as
per VDE 0472 Part 804 Test method B, IEC
60332-1)
Sheath colour: black
Outer diameter 4.9 +/-0.2 mm
Assembly (4-pin)
Bare copper litz wire, 42 x 0.10 mm
Core insulation polyester, black, brown,
white, blue
Cores stranded in layers
Sheath, special mix
weld splatter resistant, dull, low adhesion,
flame retardant and self-extinguishing (as
per VDE 0472 Part 804 Test method B, IEC
60332-1)
Sheath colour: black
Outer diameter 4.9 +/-0.2 mm

very good resistance to oil


as per VDE 0473 Part 811-2-1
good resistance to acids, alkalis and
solvents
not cross-linked
weld splatter resistant
recyclable
halogen-free
Silicone and cadmium-free
Free of substances harmful to paint
adhesion Substances
very high mechanical load capacity
abrasion resistant
wear-resistant
Highly flexible
UV-resistant
ROHS conformant
CE conformant


Note

* Design for the standard 2 LEDs in the


colours: yellow, green; 3 LEDs in the colours:
white, yellow, green - available upon request.
** Twin cables with sensor cable ROBOFLEX
recycle M12 to M8 and other configurations
and lengths - available on request.

Dimensions and specifications may be changed without prior notice.

U 57
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PVC connecting cables




Technical data

Temperature range
flexing -5 C to +70 C
Nominal voltage
H03VV-F 300/700 V
H03VV-F 300/700 V
Test voltage 2000 V
End 1: Connector
End 2: 25 respectively 30 mm stripped with
wire end ferrule

Cable structure

Note

Plain copper conductor, fine wire stranded


to DINVDE0295 cl.5, IEC60228 cl.5 and
HD383
PVC core insulation
Core identification acc. to VDE colour code
Cores stranded in layers
Green/yellow earth core (3 or more cores)
PVC outer sheath

G = with green-yellow earth core;


x = without green-yellow earth core.
On request also with international approval.

Application

H03VV-F
This cable is highly suitable as a hand tool connection for lightweight applications. It is often used as a connecting cable for household
appliances.
H05VV-F
This cable is highly suitable as a hand tool connection for medium-weight applications. It can also be used in wet rooms. As a connecting
cable: for machine installation.




Part no.
black

white

grey

84412
84413
84420
84414
84415
84422
84424
84426
86870
87127
86765
86867
86764
84437
84440
84400
84401
87748
87137
87138
84453
84402
84403
87074
84464
84467
84470
84404
84405
87142

84416
84417
84421
84418
84419
84423
84425
84427
84430
87128
87130
84434
87575
84438
84441
84406
84407
84447
87139
87140
84454
84408
84409
87141
84465
84468
84471
84410
84411
87143







84428
84429
84431
84432
84433
84435
84436
84439
84442
87725
84446
87277
84451
84452
84455
84459
87410
84460
84466
84469
84472
84475
87503
84476

Cable type /
cross-sec.
mm
H03VVH2-F  2x0,75
H03VVH2-F  2x0,75
H03VVH2-F  2x0,75
H03VV-F  2x0,75
H03VV-F  2x0,75
H03VV-F  2x0,75
H03VV-F  2x0,75
H03VV-F  2x0,75
H03VV-F  2x0,75
H05VV-F  2x1,0
H05VV-F  2x1,0
H05VV-F  2x1,0
H03VV-F  3G0,75
H03VV-F  3G0,75
H03VV-F  3G0,75
H03VV-F  3G0,75
H03VV-F  3G0,75
H03VV-F  3G0,75
H05VV-F  3G1,0
H05VV-F  3G1,0
H05VV-F  3G1,0
H05VV-F  3G1,0
H05VV-F  3G1,0
H05VV-F  3G1,0
H05VV-F  3G1,5
H05VV-F  3G1,5
H05VV-F  3G1,5
H05VV-F  3G1,5
H05VV-F  3G1,5
H05VV-F  3G1,5

Length
m
2,0
3,0
5,0
2,0
3,0
5,0
2,0
3,0
5,0
2,0
3,0
5,0
2,0
3,0
5,0
2,0
3,0
5,0
2,0
3,0
5,0
2,0
3,0
5,0
2,0
3,0
5,0
2,0
3,0
5,0

Plug type
Euro plug
Euro plug
Euro plug
Euro plug
Euro plug
Euro plug
Central contour connector
Central contour connector
Central contour connector
Central contour connector
Central contour connector
Central contour connector
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, angled
PROTECTED PLUG, angled
PROTECTED PLUG, angled
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, angled
PROTECTED PLUG, angled
PROTECTED PLUG, angled
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, angled
PROTECTED PLUG, angled
PROTECTED PLUG, angled

Cop.
weight
kg / 1000 pcs.
28,8
43,2
72,0
28,8
43,2
72,0
28,8
43,2
72,0
38,0
57,0
95,0
43,2
64,8
108,0
43,2
64,8
108,0
58,0
87,0
145,0
58,0
87,0
145,0
86,0
129,0
215,0
86,0
129,0
215,0

AWG-No.
18
18
18
18
18
18
18
18
18
17
17
17
18
18
18
18
18
18
17
17
17
17
17
17
16
16
16
16
16
16

Dimensions and specifications may be changed without prior notice.

U 58
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Rubber connecting cables




Technical data
Temperature range
flexing -30 C to +80 C
Nominal voltage
H05RR-F/H05RN-F 300/500 V
H07RN-F 450/750 V
Test voltage 3000 V
End 1: Connector
End 2: 25 respectively 30 mm stripped with
wire end ferrule

Cable structure

Note

Plain copper conductor, fine wire stranded


to DINVDE0295 cl.5, IEC60228 cl.5 and
HD383
Rubber core insulation
Core identification to VDE0293 and HD186
Cores stranded in layers
Rubber outer sheath

G = with green-yellow earth core;


x = without green-yellow earth core.
On request also with international approval.

Application

H05RR-F
Lightweight rubber-sheathed cable for use as a hand tool connection and lightweight workshop tools for light to medium-weight applications
in dry and wet rooms.
H05RN-F
Medium-weight rubber-sheathed cable for use as a hand tool connection and lightweight workshop equipment for light to medium-weight
applications in dry rooms, wet rooms outdoors and in industrial water.
H07RN-F
Heavyweight rubber-sheathed cable for use on heavy equipment and tools (agricultural, construction industry). For heavyweight applications
in dry rooms, wet rooms, outdoors and in industrial water.



Part no.
black
84481
84482
84483
87738
86961
84485
86960
87406
84487
87690
84489
84490
84492
84493
84494
86740
87145
87604
84496
84497
84498
86741
87084
84499
84653
84654
84655

Cable type /
cross-sec.
mm
H05RR-F  2x0,75
H05RR-F  2x0,75
H05RR-F  2x0,75
H05RR-F  2x1,0
H05RR-F  2x1,0
H05RR-F  2x1,0
H05RR-F  2x1,5
H05RR-F  2x1,5
H05RR-F  2x1,5
H05RR-F  3G0,75
H05RR-F  3G0,75
H05RR-F  3G0,75
H05RR-F  3G0,75
H05RR-F  3G0,75
H05RR-F  3G0,75
H07RN-F  3G1,0
H07RN-F  3G1,0
H07RN-F  3G1,0
H07RN-F  3G1,0
H07RN-F  3G1,0
H07RN-F  3G1,0
H07RN-F  3G1,5
H07RN-F  3G1,5
H07RN-F  3G1,5
H07RN-F  3G1,5
H07RN-F  3G1,5
H07RN-F  3G1,5

Length
m

Plug type

3,0
5,0
10,0
3,0
5,0
10,0
3,0
5,0
10,0
3,0
5,0
10,0
3,0
5,0
10,0
3,0
5,0
10,0
3,0
5,0
10,0
3,0
5,0
10,0
3,0
5,0
10,0

Central contour connector


Central contour connector
Central contour connector
Central contour connector
Central contour connector
Central contour connector
Central contour connector
Central contour connector
Central contour connector
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, angled
PROTECTED PLUG, angled
PROTECTED PLUG, angled
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, angled
PROTECTED PLUG, angled
PROTECTED PLUG, angled
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, angled
PROTECTED PLUG, angled
PROTECTED PLUG, angled

Cop.
weight
kg / 1000 pcs.
43,2
72,0
144,0
57,6
96,0
192,0
86,4
144,0
288,0
64,8
108,0
216,0
64,8
108,0
216,0
86,4
144,0
288,0
86,4
144,0
288,0
129,6
216,0
432,0
129,6
216,0
432,0

AWG-No.
18
18
18
17
17
17
16
16
16
18
18
18
18
18
18
17
17
17
17
17
17
16
16
16
16
16
16

Dimensions and specifications may be changed without prior notice.

U 59
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

YELLOWFLEX - connecting cable meter marking




Technical data

Cable structure

Special rubber sheathed cable acc. to


DINVDE0282 Part4, HD22.4S4
Temperature range
flexing -25 C to +60 C
fixed installation -50 C to +60 C
Permissible operating temperature
at conductor +60 C
Nominal voltage U0/U 450/750 V
with protected fixed installation
U0/U 600/1000 V
Highest permissible operating voltage
in three-phase and one-phase
a.c. systems U0/U 476/825 V
in d.c. systems U0/U 619/1238 V
Test voltage 2500 V
Minimum bending radius
flexible
up to 12 mm cable : 3x cable
greater than 12 mm cable : 4 x 6 cable
End 1: Plug
End 2: 30 mm stripped with wire end
ferrule

Bare copper conductor, fine wire to


DINVDE0295 cl.5, BS6360 cl.5, IEC60228
cl.5 and/or HD383
Rubber core insulation, EI4 to DIN VDE 0282
part4
Core colours according DIN VDE 0293-308
Core colour:
 - up to 5 cores one-coloured
 - up 6 and more cores, black with white
numbering
 - 3 and above, with green-yellow earth
core
 - 2 cores without green-yellow earth
core
Cores stranded in layers with optimal
lay-length
Special outer sheath, EM2 to DIN VDE 0282
part 1
Sheath colour Yellow (RAL 1021)
with meter marking, change-over in 2011

Properties
Tests
Flame-retardant acc. to VDE 0482-332-1-2,
DIN EN 60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Increased stability
Tear-resistant
Resistant to
Atmospheric influences
Hydrolysis
UV-radiation
Largely resistant to
Oils and fats 
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Note

G = with green-yellow earth core;


x = without green-yellow earth core.

Application
These robust special rubber sheathed cables can be used where high demands are placed, flexibility and mechanical stress. For application
on construction sites, in steel works and rolling mills in heating and air-conditioning systems, in the bottling industry, in machinery and plant
construction, in the chemical industry and painting systems, as well as for the professional and the hobby enthusiast. The choice of yellow
as the sheath colour ensures additional safety. Can be used in potentially explosive areas acc. to DINVDE0165.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
orange
650950
650951
650952
650953
650958
650959
650960
650961
650954
650955
650956
650957
650962
650963
650964
650965

Cable type /
cross-sec.
mm
YELLOWFLEX  2x1,0
YELLOWFLEX  2x1,0
YELLOWFLEX  2x1,0
YELLOWFLEX  2x1,0
YELLOWFLEX  2x1,5
YELLOWFLEX  2x1,5
YELLOWFLEX  2x1,5
YELLOWFLEX  2G1,5
YELLOWFLEX  3G1,0
YELLOWFLEX  3G1,0
YELLOWFLEX  3G1,0
YELLOWFLEX  3G1,0
YELLOWFLEX  3G1,5
YELLOWFLEX  3G1,5
YELLOWFLEX  3G1,5
YELLOWFLEX  3G1,5

Length
m

Plug type

2,0
3,0
5,0
10,0
2,0
3,0
5,0
10,0
2,0
3,0
5,0
10,0
2,0
3,0
5,0
10,0

Central contour connector


Central contour connector
Central contour connector
Central contour connector
Central contour connector
Central contour connector
Central contour connector
Central contour connector
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight

Cop.
weight
kg / 1000 pcs.
38,0
57,0
95,0
190,0
58,0
87,0
145,0
290,0
58,0
87,0
145,0
290,0
86,0
129,0
215,0
430,0

AWG-No.
17
17
17
17
16
16
16
16
17
17
17
17
16
16
16
16

Dimensions and specifications may be changed without prior notice.

U 60
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR connecting cables, orange




Technical data

Temperature range
-40 C to +90 C
Nominal voltage
H05BQ-F 300/500 V
H07BQ-F 450/750 V
Test voltage 3000 V
End 1: Plug
End 2: 30 mm stripped with wire end
ferrule

Cable structure

Note

Tinned copper conductor, fine wire


stranded
Rubber core insulation
Cores stranded
Cores colour coded to VDE0293
PUR outer sheath orange

G = with green-yellow earth core


x = without green-yellow earth core
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
These cables can be used for medium mechanical loads in dry, damp or wet environments, e.g. for connecting agricultural and commercial
equipment and heaters provided there is no danger of contact with the hot parts or by radiation of heat. These robust and flexible cables
are used for electrical tools such as drills and hand-held circular saws, as well as for portable motors and machinery in agriculture, at building
sites, docks and refrigeration plants.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
orange
84656
87802
84657
84658
84663
84664
84665
84666
84669
84670
86989
84671
84659
84660
84661
84662
84667
86775
86774
84668
84672
86782
87548
84673

Cable type /
cross-sec.
mm
H05BQ-F  2x0,75
H05BQ-F  2x0,75
H05BQ-F  2x0,75
H05BQ-F  2x0,75
H05BQ-F  2x1,0
H05BQ-F  2x1,0
H05BQ-F  2x1,0
H05BQ-F  2x1,0
H07BQ-F  2x1,5
H07BQ-F  2x1,5
H07BQ-F  2x1,5
H07BQ-F  2x1,5
H05BQ-F  3G0,75
H05BQ-F  3G0,75
H05BQ-F  3G0,75
H05BQ-F  3G0,75
H05BQ-F  3G1,0
H05BQ-F  3G1,0
H05BQ-F  3G1,0
H05BQ-F  3G1,0
H07BQ-F  3G1,5
H07BQ-F  3G1,5
H07BQ-F  3G1,5
H07BQ-F  3G1,5

Length
m

Plug type

2,0
3,0
5,0
10,0
2,0
3,0
5,0
10,0
2,0
3,0
5,0
10,0
2,0
3,0
5,0
10,0
2,0
3,0
5,0
10,0
2,0
3,0
5,0
10,0

Central contour connector


Central contour connector
Central contour connector
Central contour connector
Central contour connector
Central contour connector
Central contour connector
Central contour connector
Central contour connector
Central contour connector
Central contour connector
Central contour connector
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight
PROTECTED PLUG, straight

Cop.
weight
kg / 1000 pcs.
28,8
43,2
72,0
144,0
38,4
57,6
96,0
192,0
58,0
87,0
145,0
290,0
43,2
64,8
108,0
216,0
58,0
87,0
145,0
290,0
86,0
129,0
215,0
430,0

AWG-No.
18
18
18
18
17
17
17
17
16
16
16
16
18
18
18
18
17
17
17
17
16
16
16
16

Dimensions and specifications may be changed without prior notice.

U 61
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Extensions / Supply cables

CEE-Extensions / Cold equipment /

PVC-Extensions


CEE-Extensions
Part no.
84688
84689
87164
84690
84691
87416

Cable type /
cross-sec.
mm
H07RN-F  5G1,5
H07RN-F  5G1,5
H07RN-F  5G1,5
H07RN-F  5G2,5
H07RN-F  5G2,5
H07RN-F  5G2,5

Length
m

Cable colour

Plug 1

Plug 2

AWG-No.

5,0
10,0
25,0
5,0
10,0
25,0

black
black
black
black
black
black

CEE connector 16A


CEE connector 16A
CEE connector 16A
CEE connector 32A
CEE connector 32A
CEE connector 32A

CEE coupling 16A


CEE coupling 16A
CEE coupling 16A
CEE coupling 32A
CEE coupling 32A
CEE coupling 32A

16
16
16
14
14
14

Cable colour

Plug 1

Plug 2

AWG-No.

black
grey
black
grey
black
grey
black
grey

PROTECTED PLUG, angled


PROTECTED PLUG, angled
PROTECTED PLUG, angled
PROTECTED PLUG, angled
PROTECTED PLUG, angled
PROTECTED PLUG, angled
PROTECTED PLUG, angled
PROTECTED PLUG, angled

Cold device socket


Cold device socket
Cold device socket
Cold device socket
Cold device socket
Cold device socket
Cold device socket
Cold device socket

18
18
18
18
17
17
17
17

Cable colour

Plug 1

Plug 2

AWG-No.

white
white
white

PROTECTED PLUG, straight


PROTECTED PLUG, straight
PROTECTED PLUG, straight

PROTECTED PLUG coupling


PROTECTED PLUG coupling
PROTECTED PLUG coupling

16
16
16

Cold
equipments + PVC-Extensions

Part no.
87476
86762
84674
87845
87196
84675
87549
84676

Cable type /
cross-sec.
mm
H05VV-F  3G0,75
H05VV-F  3G0,75
H05VV-F  3G0,75
H05VV-F  3G0,75
H05VV-F  3G1,0
H05VV-F  3G1,0
H05VV-F  3G1,0
H05VV-F  3G1,0

Length
m

Cable type /
cross-sec.
mm
H05VV-F  3G1,5
H05VV-F  3G1,5
H05VV-F  3G1,5

Length
m

2,0
2,0
3,0
3,0
2,0
2,0
3,0
3,0


Part no.
87445
87919
84178

2,0
3,0
5,0

Dimensions and specifications may be changed without prior notice.

U 62
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Front connecting cables for Simatic S7




Cable structure

Properties

Cable cores 0,75 mm in dark blue (RAL


5010)
Printed characters in white
Numbers according to allocation in the
plug
Original front connector can be completely
allocated
Cores cut flush
Customised pre-assembly possible

Other lengths, dimensions, colours and


specials conditions possible on request

Advantages
Tremendous time savings
Quick wiring
Considerably easier troubleshooting
Customised pre-assembled cable


Note

Application
These pre-assembled cables with pre-wired front connectors are highly suitable for Simatic S7 programmable logic controllers (PLC).
As opposed to past days when you had to cut to length, strip, crimp, screw in and mark, pre-wired front connectors offer the customer a
host of advantages for the Simatic S7 system.



Part no.
Front connector,
650091
650200
650201
84867
84868
84869
650202
650203
650088
Front connector,
650092
650204
650205
84870
84871
84872
650206
650207
650086
Front connector,
650208
650209
650210
650211
650212
650213
84873
84874
84875

Connection type
20-pole
Screw fitting version
Screw fitting version
Screw fitting version
Spring version
Spring version
Spring version
Crimp version
Crimp version
Crimp version
40-pole
Screw fitting version
Screw fitting version
Screw fitting version
Spring version
Spring version
Spring version
Crimp version
Crimp version
Crimp version
48-pole
Screw fitting version
Screw fitting version
Screw fitting version
Spring version
Spring version
Spring version
Crimp version
Crimp version
Crimp version

Length
m

Cop.
weight
kg / 1000 pcs.

AWG-No.

2,0
3,0
5,0
2,0
3,0
5,0
2,0
3,0
5,0

324,0
468,0
756,0
324,0
468,0
756,0
324,0
468,0
756,0

18
18
18
18
18
18
18
18
18

2,0
3,0
5,0
2,0
3,0
5,0
2,0
3,0
5,0

648,0
936,0
1512,0
648,0
936,0
1512,0
648,0
936,0
1512,0

18
18
18
18
18
18
18
18
18

2,0
3,0
5,0
2,0
3,0
5,0
2,0
3,0
5,0

746,0
1077,0
1739,0
746,0
1077,0
1739,0
746,0
1077,0
1739,0

18
18
18
18
18
18
18
18
18

Dimensions and specifications may be changed without prior notice.

U 63
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Spiral Cables

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Spiral Cables

V1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Spiral Cables
The use of spiral cables is necessary in nearly all
market segments.
Whether in the communications sector, medical
engineering, the automotive industry, mechanical
and plant engineering, etc. or as supply wires
for the lamp industry - spiral cables are used
everywhere.
Along with the electrical/mechanical uses, spiral
cables are frequently also an excellent solution for
designing the optical appearance.
When using PVC or PUR spiral cables, it is often
possible to match the supply wire to the object.
Copper-shielded spiral cables can also be supplied.
PVC spiral cable:
Low mechanical and chemical tolerance, medium
recoil strength, appearance (various colors
possible).
PUR spiral cable:
The ideal solution in most cases. Excellent
chemically, mechanically, thermally and in
appearance (various colors possible). Very good
recoil strength.

V2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description
PVC spiral cables.................................................................................................................................................................................
PUR spiral cables black.......................................................................................................................................................................
PUR spiral cables orange....................................................................................................................................................................
PUR electronic spiral cables unscreened...........................................................................................................................................

PUR electronic spiral cables screened...............................................................................................................................................

Page
V 4
V 5
V 7
V 9

V 11

V3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PVC spiral cables




Technical data

Cable structure

Note

Temperature range
-5 C to +70 C
Nominal voltage
H03VV-F 300/300 V (up to 1mm2)
H05VV-F 300/500 V (from 1,5mm2)
Test voltage
2000 V
Expansion ratio 1:3
straight ends
200/200 mm

Bare copper, fine wire conductors to


VDE0295 cl.5
PVC core insulation
Cores stranded
Cores colour coded to VDE0293
PVC outer sheath

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
As well in axial construction
On request closed spiral lengths up to max.
5000 mm possible.

Application
Lighting industry
Data installations
Shops



Part no.
black

white

Cross-section
mm

84500
84502
84504
84506
84508
84509
84510
84517
84519
84521
84523
84525
84526
84527
84534
84536
84538
84540
84542
84543
84544
84585
84587
84589
84591
84593
84594
84595
84602
84604
84606
84608
84610
84611
84612

84700
84702
84704
84706
84708
84709
84710
84717
84719
84721
84723
84725
84726
84727
84734
84736
84738
84740
84742
84743
84744
84785
84787
84789
84791
84793
84794
84795
84802
84804
84806
84808
84810
84811
84812

2x0,75
2x0,75
2x0,75
2x0,75
2x0,75
2x0,75
2x0,75
3G0,75
3G0,75
3G0,75
3G0,75
3G0,75
3G0,75
3G0,75
2x1,0
2x1,0
2x1,0
2x1,0
2x1,0
2x1,0
2x1,0
2x1,5
2x1,5
2x1,5
2x1,5
2x1,5
2x1,5
2x1,5
3G1,5
3G1,5
3G1,5
3G1,5
3G1,5
3G1,5
3G1,5

Spiral length
unexpanded
(WL in mm)
200
400
600
800
1000
1200
1400
200
400
600
800
1000
1200
1400
200
400
600
800
1000
1200
1400
200
400
600
800
1000
1200
1400
200
400
600
800
1000
1200
1400

Cable
approx. mm
6,2
6,2
6,2
6,2
6,2
6,2
6,2
6,6
6,6
6,6
6,6
6,6
6,6
6,6
6,6
6,6
6,6
6,6
6,6
6,6
6,6
7,7
7,7
7,7
7,7
7,7
7,7
7,7
8,5
8,5
8,5
8,5
8,5
8,5
8,5

Spiralouter
approx. mm
21,4
21,4
21,4
21,4
21,4
21,4
21,4
22,2
22,2
22,2
22,2
22,2
22,2
22,2
22,2
22,2
22,2
22,2
22,2
22,2
22,2
26,4
26,4
26,4
26,4
26,4
26,4
26,4
29,0
29,0
29,0
29,0
29,0
29,0
29,0

Cop.
weight
kg / 1000 pcs.
34,6
63,4
92,2
121,0
149,8
178,6
207,4
51,9
95,1
138,3
181,5
224,7
267,8
311,1
43,2
65,3
122,8
161,3
199,7
238,1
276,5
69,6
127,0
185,6
243,6
301,6
359,6
417,6
103,2
189,2
275,2
361,2
447,2
533,2
619,2

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16

Dimensions and specifications may be changed without prior notice.

V4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR spiral cables black




Technical data

Cable structure

Note

Temperature range
-25 C to +70 C
Nominal voltage
H05BQ-F 300/500 V (up to 1mm2)
H07BQ-F 450/750 V (from 1,5mm2)
Test voltage
2000/2500 V
Expansion ratio 1:4
straight ends
200/200 mm

Plain copper conductor, fine wire stranded


to DINVDE0295 cl.5
EPDM core insulation
VDE-approved cable
PUR outer sheath
Colour black

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
As well in axial construction
On request closed spiral lengths up to max.
5000 mm possible.

Application

Machine Construction
Electrical Tools
Building Industry
Handling Equipment
Entertainment Equipment


Part no.
black

Cross-section
mm

86303
86306
86308
86311
86315
86319
86322
86324
86327
86331
86335
86338
86340
86343
86347
86351
86354
86356
86359
86363
86367
86370
86372
86375
86379
84903
84906
84908
84911
84915
86383
86386
86388
86391
86395
86399
86402
86404
86407
86411

2x0,75
2x0,75
2x0,75
2x0,75
2x0,75
3G0,75
3G0,75
3G0,75
3G0,75
3G0,75
4G0,75
4G0,75
4G0,75
4G0,75
4G0,75
5G0,75
5G0,75
5G0,75
5G0,75
5G0,75
2x1,0
2x1,0
2x1,0
2x1,0
2x1,0
3G1,0
3G1,0
3G1,0
3G1,0
3G1,0
4G1,0
4G1,0
4G1,0
4G1,0
4G1,0
5G1,0
5G1,0
5G1,0
5G1,0
5G1,0

Spiral length
unexpanded
(WL in mm)
500
1000
1400
2000
3000
500
1000
1400
2000
3000
500
1000
1400
2000
3000
500
1000
1400
2000
3000
500
1000
1400
2000
3000
500
1000
1400
2000
3000
500
1000
1400
2000
3000
500
1000
1400
2000
3000

Cable
approx. mm
6,5
6,5
6,5
6,5
6,5
7,1
7,1
7,1
7,1
7,1
7,9
7,9
7,9
7,9
7,9
8,6
8,6
8,6
8,6
8,6
6,8
6,8
6,8
6,8
6,8
7,2
7,2
7,2
7,2
7,2
7,8
7,8
7,8
7,8
7,8
9,0
9,0
9,0
9,0
9,0

Spiralouter
approx. mm
23,0
23,0
23,0
23,0
23,0
25,2
25,2
25,2
25,2
25,2
28,8
28,8
28,8
28,8
28,8
31,2
31,2
31,2
31,2
31,2
24,6
24,6
24,6
24,6
24,6
26,4
26,4
26,4
26,4
26,4
28,6
28,6
28,6
28,6
28,6
32,0
32,0
32,0
32,0
32,0

Cop.
weight
kg / 1000 pcs.
77,8
149,8
207,4
293,8
437,8
116,7
224,7
311,1
440,6
656,6
156,6
301,6
417,6
591,6
881,6
194,4
374,4
518,4
734,4
1094,4
103,7
199,7
276,5
391,7
583,7
156,6
301,6
417,6
591,6
881,6
207,4
399,4
553,0
783,4
1167,4
259,2
499,2
691,2
979,2
1459,2

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17

Continuation

V5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR spiral cables black



Part no.
black

Cross-section
mm

86415
86418
86420
86423
86427
86463
86466
86468
86471
86475
84919
84922
84924
84927
84931
84951
84954
84956
84959
84963
84967
84970
84972
84975
84979
86479
86482
86484
86487
86491

7G1,0
7G1,0
7G1,0
7G1,0
7G1,0
2x1,5
2x1,5
2x1,5
2x1,5
2x1,5
3G1,5
3G1,5
3G1,5
3G1,5
3G1,5
5G1,5
5G1,5
5G1,5
5G1,5
5G1,5
7G1,5
7G1,5
7G1,5
7G1,5
7G1,5
3G2,5
3G2,5
3G2,5
3G2,5
3G2,5

Spiral length
unexpanded
(WL in mm)
500
1000
1400
2000
3000
500
1000
1400
2000
3000
500
1000
1400
2000
3000
500
1000
1400
2000
3000
500
1000
1400
2000
3000
500
1000
1400
2000
3000

Cable
approx. mm
11,1
11,1
11,1
11,1
11,1
8,5
8,5
8,5
8,5
8,5
8,9
8,9
8,9
8,9
8,9
10,9
10,9
10,9
10,9
10,9
12,2
12,2
12,2
12,2
12,2
10,6
10,6
10,6
10,6
10,6

Spiralouter
approx. mm
39,0
39,0
39,0
39,0
39,0
30,0
30,0
30,0
30,0
30,0
32,8
32,8
32,8
32,8
32,8
38,8
38,8
38,8
38,8
38,8
46,4
46,4
46,4
46,4
46,4
38,2
38,2
38,2
38,2
38,2

Cop.
weight
kg / 1000 pcs.
361,8
696,8
964,8
1366,8
2036,8
156,6
301,6
417,6
591,6
881,6
232,2
447,2
619,2
877,2
1307,2
388,8
748,8
1036,8
1468,8
2188,8
545,4
1050,4
1454,1
2060,4
3070,4
388,8
748,8
1036,8
1468,8
2188,8

AWG-No.
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14

Dimensions and specifications may be changed without prior notice.

V6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR spiral cables orange




Technical data

Cable structure

Temperature range
-25 C to +70 C
Nominal voltage
H05BQ-F 300/500 V (up to 1mm2)
H07BQ-F 450/750 V (from 1,5mm2)
Test voltage
2000/2500 V
Expansion ratio 1:4
straight ends
200/200 mm

Note

Plain copper conductor, fine wire stranded


EPDM core insulation
VDE-approved cable
PUR outer sheath
Sheath colour orange

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
As well in axial construction
On request closed spiral lengths up to max.
5000 mm possible.

Application

Machine Construction
Electrical Tools
Building Industry
Handling Equipment
Entertainment Equipment


Part no.
orange

Cross-section
mm

85221
85223
85226
85229
85236
85238
85240
85243
85246
85253
85255
85257
85260
85263
85270
85272
85274
85277
85280
85287
85289
85291
85294
85297
85304
85306
85308
85311
85314
85321
85323
85325
85328
85331
85338
85340
85342
85345
85348
85355

2x0,75
2x0,75
2x0,75
2x0,75
2x0,75
3G0,75
3G0,75
3G0,75
3G0,75
3G0,75
4G0,75
4G0,75
4G0,75
4G0,75
4G0,75
5G0,75
5G0,75
5G0,75
5G0,75
5G0,75
2x1,0
2x1,0
2x1,0
2x1,0
2x1,0
3G1,0
3G1,0
3G1,0
3G1,0
3G1,0
4G1,0
4G1,0
4G1,0
4G1,0
4G1,0
5G1,0
5G1,0
5G1,0
5G1,0
5G1,0

Spiral length
unexpanded
(WL in mm)
300
500
1000
1500
3000
300
500
1000
1500
3000
300
500
1000
1500
3000
300
500
1000
1500
3000
300
500
1000
1500
3000
300
500
1000
1500
3000
300
500
1000
1500
3000
300
500
1000
1500
3000

Cable
approx. mm
6,5
6,5
6,5
6,5
6,5
7,1
7,1
7,1
7,1
7,1
7,9
7,9
7,9
7,9
7,9
8,6
8,6
8,6
8,6
8,6
6,8
6,8
6,8
6,8
6,8
7,2
7,2
7,2
7,2
7,2
7,8
7,8
7,8
7,8
7,8
9,0
9,0
9,0
9,0
9,0

Spiralouter
approx. mm
23,0
23,0
23,0
23,0
23,0
25,2
25,2
25,2
25,2
25,2
28,8
28,8
28,8
28,8
28,8
31,2
31,2
31,2
31,2
31,2
24,6
24,6
24,6
24,6
24,6
26,4
26,4
26,4
26,4
26,4
28,6
28,6
28,6
28,6
28,6
32,0
32,0
32,0
32,0
32,0

Cop.
weight
kg / 1000 pcs.
59,0
77,8
149,8
221,8
437,8
73,5
116,7
224,7
332,6
656,6
98,6
156,6
301,6
446,6
881,6
122,4
194,4
374,4
554,4
1094,4
65,3
103,7
199,7
295,7
583,7
98,6
156,6
301,6
446,6
881,6
130,6
207,4
399,4
591,4
1167,4
163,2
259,2
499,2
739,2
1459,2

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17

Continuation

V7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR spiral cables orange



Part no.
orange

Cross-section
mm

85357
85359
85362
85365
85372
85374
85376
85379
85382
85389
85408
85410
85413
85416
85423
85425
85427
85430
85433
85440
85442
85444
85447
85450
85457
85459
85461
85464
85467
85474
85493
85495
85498
85501
85508

2x1,5
2x1,5
2x1,5
2x1,5
2x1,5
3G1,5
3G1,5
3G1,5
3G1,5
3G1,5
5G1,5
5G1,5
5G1,5
5G1,5
5G1,5
7G1,5
7G1,5
7G1,5
7G1,5
7G1,5
12G1,5
12G1,5
12G1,5
12G1,5
12G1,5
3G2,5
3G2,5
3G2,5
3G2,5
3G2,5
5G2,5
5G2,5
5G2,5
5G2,5
5G2,5

Spiral length
unexpanded
(WL in mm)
300
500
1000
1500
3000
300
500
1000
1500
3000
300
500
1000
1500
3000
300
500
1000
1500
3000
300
500
1000
1500
3000
300
500
1000
1500
3000
300
500
1000
1500
3000

Cable
approx. mm
8,5
8,5
8,5
8,5
8,5
8,9
8,9
8,9
8,9
8,9
10,9
10,9
10,9
10,9
10,9
12,6
12,6
12,6
12,6
12,6
16,6
16,6
16,6
16,6
16,6
10,6
10,6
10,6
10,6
10,6
13,2
13,2
13,2
13,2
13,2

Spiralouter
approx. mm
30,0
30,0
30,0
30,0
30,0
32,8
32,8
32,8
32,8
32,8
38,8
38,8
38,8
38,8
38,8
46,4
46,4
46,4
46,4
46,4
65,2
65,2
65,2
65,2
65,2
38,2
38,2
38,2
38,2
38,2
48,4
48,4
48,4
48,4
48,4

Cop.
weight
kg / 1000 pcs.
98,6
156,6
301,6
446,6
881,6
146,2
232,2
447,2
662,2
1307,2
244,8
388,8
748,8
1108,8
2188,8
343,4
545,4
1050,4
1555,4
3070,4
588,2
934,2
1799,2
2664,2
5259,2
244,8
388,8
748,8
1108,8
2188,8
408,0
648,0
1248,0
1848,0
3648,0

AWG-No.
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14
14
14

Dimensions and specifications may be changed without prior notice.

V8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR electronic spiral cables unscreened




Technical data

Cable structure

Note

Temperature range
-25 C to +70 C
Nominal voltage
300 V (up to 0,14 mm)
500 V (from 0,25 mm)
Test voltage
1000 V
Expansion ratio 1:4
straight ends
200/200 mm

Bare copper, fine wire conductor to


VDE0295 cl.6, IEC 60228 cl. 6
TPE-E core insulation
Core identification to DIN47100
Cores stranded in layers
PUR outer sheath
Colour black

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
As well in axial construction
On request closed spiral lengths up to max.
5000 mm possible.

Application
Control technology use



Part no.
black

Cross-section
mm

85550
85551
85552
85555
85566
85567
85568
85571
85574
85575
85576
85579
85582
85583
85584
85587
85590
85591
85592
85595
85598
85599
85600
85603
85638
85639
85640
85643
85654
85655
85656
85659
85662
85663
85664
85667
85670
85671
85672
85675

2x0,14
2x0,14
2x0,14
2x0,14
4x0,14
4x0,14
4x0,14
4x0,14
5x0,14
5x0,14
5x0,14
5x0,14
6x0,14
6x0,14
6x0,14
6x0,14
7x0,14
7x0,14
7x0,14
7x0,14
8x0,14
8x0,14
8x0,14
8x0,14
2x0,25
2x0,25
2x0,25
2x0,25
4x0,25
4x0,25
4x0,25
4x0,25
5x0,25
5x0,25
5x0,25
5x0,25
6x0,25
6x0,25
6x0,25
6x0,25

Spiral length
unexpanded
(WL in mm)
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000

Cable
approx. mm
3,5
3,5
3,5
3,5
4,0
4,0
4,0
4,0
4,4
4,4
4,4
4,4
4,9
4,9
4,9
4,9
5,2
5,2
5,2
5,2
5,4
5,4
5,4
5,4
3,9
3,9
3,9
3,9
4,6
4,6
4,6
4,6
5,4
5,4
5,4
5,4
5,5
5,5
5,5
5,5

Spiralouter
approx. mm
13,0
13,0
13,0
13,0
14,0
14,0
14,0
14,0
15,8
15,8
15,8
15,8
17,8
17,8
17,8
17,8
18,4
18,4
18,4
18,4
19,8
19,8
19,8
19,8
13,8
13,8
13,8
13,8
17,2
17,2
17,2
17,2
19,8
19,8
19,8
19,8
20,0
20,0
20,0
20,0

Cop.
weight
kg / 1000 pcs.
9,2
11,9
15,6
28,1
18,4
23,8
29,2
56,2
22,8
29,5
36,2
69,7
27,5
36,7
43,8
84,2
32,0
42,4
50,8
97,8
36,7
47,5
58,3
112,3
16,3
21,1
25,9
49,9
36,7
42,2
51,8
99,8
40,8
52,8
64,8
124,8
48,9
63,4
77,8
149,8

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24

Continuation

V9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR electronic spiral cables unscreened



Part no.
black

Cross-section
mm

85686
85687
85688
85691
85702
85703
85704
85707
85726
85727
85728
85731
85742
85743
85744
85747
85758
85759
85760
85763
85774
85775
85776
85779
85790
85791
85792
85795

8x0,25
8x0,25
8x0,25
8x0,25
12x0,25
12x0,25
12x0,25
12x0,25
2x0,5
2x0,5
2x0,5
2x0,5
4x0,5
4x0,5
4x0,5
4x0,5
6x0,5
6x0,5
6x0,5
6x0,5
8x0,5
8x0,5
8x0,5
8x0,5
12x0,5
12x0,5
12x0,5
12x0,5

Spiral length
unexpanded
(WL in mm)
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000

Cable
approx. mm
6,4
6,4
6,4
6,4
6,9
6,9
6,9
6,9
4,6
4,6
4,6
4,6
5,0
5,0
5,0
5,0
6,2
6,2
6,2
6,2
7,4
7,4
7,4
7,4
8,2
8,2
8,2
8,2

Spiralouter
approx. mm
23,8
23,8
23,8
23,8
24,8
24,8
24,8
24,8
16,2
16,2
16,2
16,2
18,0
18,0
18,0
18,0
22,4
22,4
22,4
22,4
26,8
26,8
26,8
26,8
29,4
29,4
29,4
29,4

Cop.
weight
kg / 1000 pcs.
65,3
84,5
103,7
199,7
97,9
126,7
155,5
299,5
32,6
42,3
51,8
99,8
65,3
84,5
103,7
201,8
97,9
126,7
155,5
299,5
130,6
169,0
207,4
399,4
195,8
254,3
311,1
599,1

AWG-No.
24
24
24
24
24
24
24
24
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

Dimensions and specifications may be changed without prior notice.

V 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR electronic spiral cables screened




Technical data

Cable structure

Note

Temperature range
-25 C to +70 C
Nominal voltage
300 V (up to 0,14 mm)
500 V (from 0,25 mm)
Test voltage
2000 V
Expansion ratio 1:4
straight ends
200/200 mm

Bare copper, fine wire conductor to


VDE0295 cl.6 and IEC60228 cl.6
TPE-E core insulation
Core identification to DIN47100
Cores stranded in layers
Overall screening
PUR sheath
Colour black

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
As well in axial construction
On request closed spiral lengths up to max.
5000 mm possible.

Application
Control technology use



Part no.
black

Cross-section
mm

85900
85901
85902
85905
600154
600155
600156
600157
85916
85917
85918
85921
85924
85925
85926
85929
85932
85933
85934
85937
85940
85941
85942
85945
85948
85949
85950
85953
85980
85981
85982
85985
85988
85989
85990
85993
85996
85997
85998
86001

2x0,14
2x0,14
2x0,14
2x0,14
3x0,14
3x0,14
3x0,14
3x0,14
4x0,14
4x0,14
4x0,14
4x0,14
5x0,14
5x0,14
5x0,14
5x0,14
6x0,14
6x0,14
6x0,14
6x0,14
7x0,14
7x0,14
7x0,14
7x0,14
8x0,14
8x0,14
8x0,14
8x0,14
2x0,25
2x0,25
2x0,25
2x0,25
4x0,25
4x0,25
4x0,25
4x0,25
5x0,25
5x0,25
5x0,25
5x0,25

Spiral length
unexpanded
(WL in mm)
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000

Cable
approx. mm
3,8
3,8
3,8
3,8
4,1
4,1
4,1
4,1
4,6
4,6
4,6
4,6
4,6
4,6
4,6
4,6
5,2
5,2
5,2
5,2
5,5
5,5
5,5
5,5
5,6
5,6
5,6
5,6
4,5
4,5
4,5
4,5
5,0
5,0
5,0
5,0
5,4
5,4
5,4
5,4

Spiralouter
approx. mm
13,6
13,6
13,6
13,6
15,2
15,2
15,2
15,2
16,2
16,2
16,2
16,2
17,2
17,2
17,2
17,2
19,4
19,4
19,4
19,4
20,0
20,0
20,0
20,0
20,2
20,2
20,2
20,2
16,0
16,0
16,0
16,0
18,0
18,0
18,0
18,0
19,8
19,8
19,8
19,8

Cop.
weight
kg / 1000 pcs.
30,6
39,6
48,6
93,6
44,2
55,8
67,5
135,0
47,6
61,6
75,6
145,6
54,4
70,4
86,4
166,4
64,6
83,6
102,6
197,6
68,0
88,0
108,0
208,0
74,8
96,8
118,8
228,8
51,0
66,0
81,0
156,0
74,8
96,8
118,8
228,8
85,0
110,0
135,0
260,0

AWG-No.
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
24
24
24
24
24
24
24
24
24
24
24
24

Continuation

V 11
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

PUR electronic spiral cables screened



Part no.
black

Cross-section
mm

86004
86005
86006
86009
86012
86013
86014
86017
86020
86021
86022
86025
86036
86037
86038
86041
86044
86045
86046
86049
86052
86053
86054
86057
86060
86061
86062
86065
86068
86069
86070
86073

6x0,25
6x0,25
6x0,25
6x0,25
8x0,25
8x0,25
8x0,25
8x0,25
12x0,25
12x0,25
12x0,25
12x0,25
2x0,5
2x0,5
2x0,5
2x0,5
4x0,5
4x0,5
4x0,5
4x0,5
6x0,5
6x0,5
6x0,5
6x0,5
8x0,5
8x0,5
8x0,5
8x0,5
12x0,5
12x0,5
12x0,5
12x0,5

Spiral length
unexpanded
(WL in mm)
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000
300
400
500
1000

Cable
approx. mm
5,7
5,7
5,7
5,7
6,5
6,5
6,5
6,5
7,1
7,1
7,1
7,1
5,5
5,5
5,5
5,5
5,8
5,8
5,8
5,8
7,0
7,0
7,0
7,0
8,0
8,0
8,0
8,0
8,8
8,8
8,8
8,8

Spiralouter
approx. mm
20,4
20,4
20,4
20,4
23,0
23,0
23,0
23,0
26,2
26,2
26,2
26,2
20,0
20,0
20,0
20,0
21,6
21,6
21,6
21,6
26,0
26,0
26,0
26,0
29,0
29,0
29,0
29,0
31,6
31,6
31,6
31,6

Cop.
weight
kg / 1000 pcs.
102,0
132,0
162,0
312,0
119,0
154,0
189,0
364,0
170,0
220,0
270,0
520,0
78,2
101,2
124,2
239,2
153,0
198,0
243,0
648,0
231,2
299,2
367,2
707,2
289,0
374,0
459,0
884,0
380,8
492,8
604,8
1164,8

AWG-No.
24
24
24
24
24
24
24
24
24
24
24
24
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

Dimensions and specifications may be changed without prior notice.

V 12
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Inquiry Spiral Cable


Please send inquiry to:
MARYLAND METRICS
P.O. Box 261
Owings Mills, MD 21117 USA
ph: (410)358-3130 (800)638-1830
fx: (410)358-3142 (800)872-9329
email: sales@mdmetric.com
web: http://mdmetric.com

Sender (stamp)

Contact
Phone

Enquiry

Fax

No.

Requirement

pcs

Date

yearly requirement approx.

once

continuous
pcs

... also available with


ready moulded or
mounted plugs

1/
:/
:'
D[LDO

.'
WDQJHQWLDO
6

/

/

/

6

If you should require a special design please


enclose a sketch

/

1. Sheath type

PVC

PUR

2. Outer sheath colour


3. Type

No. of cores x cross section

4. Screen

mm

yes:

5. Spiral length

(WL closed)

6. Max. elongation

(extended spiral)

7. Spiral outer diameter

WD

8. Internal diameter

KD

9. End lengths

(axial or tangential)
S1

mm

S2

mm

Comments

Characteristics PVC (Polyvinylchlorid)


PVC spiral cables offer a high degree of economy. They are suitable for installation wherever a light duty cable is required.

Characteristics PUR (Polyurethan)


Good resistance to chemicals and cold conditions. Good performance characteristics in all weather conditions, excellent
mechanical properties such as tear and abrasion resistance, excellent oil resistance.

V 13
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Shipwiring and Marine Cables

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: HELUKABEL

Shipwiring
and Marine Cables

W1
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Shipwiring and Marine Cables


We offer shipwiring and marine cables with
approvals of the Germanischer Lloyd, Lloyds
Register of Shipping, American Bureau of
Shipping, Det Norske Veritas, Bureau Veritas, USSR
Register of Shipping and the Verband Deutscher
Elektrotechniker.
Great parts of the programm are available within
a short time from our stock. Cutting lengths are
available for an additional charge. On request we
send with each order a corresponding production
or company certicate.

W2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents
Description

Page

Ships Power Cables MGSGO,halogen-free, copper screened.......................................................................................................................


Light Marine Power Cables XLFMKK,Cu-screened.................................................................................................................................

Marine Power Cables LMGSGO,halogen-free, Cu-screened........................................................................................................................


Ships Telephone Cables FMGCH 250 V (FMGCG*),halogen-free according to DIN 89 159/99.........................................................................

Marine Telecommunication Cables FMGSGO,halogen-free, Cu-screened.................................................................................................


Marine Telecommunication Cables FMSGSGO 250 V,with a single screen, higher cross-talk atttenuation, halogen-free......................................

Light Marine Telekommunication Cables LFMGSSGO,halogen-free, 2x Cu-screened.................................................................................


Light Marine Telecommunication Cables LFMSGSSGO,halogen-free, 2x Cu-screened...............................................................................
Ships Wiring Cables-SY single cores...................................................................................................................................................
Ships Wiring Cables-SY stranded type...............................................................................................................................................

Ships Power Cables MPRX 0,6/1kV,according to IEC 60092-353, halogen-free..............................................................................................


Ships Power Cables MPRXCX 0,6/1kV,according to IEC 60092-353, halogen-free..........................................................................................
SHIPFLEX 512,cable for drag chain, halogen-free,

........................................................................
SHIPFLEX 330,cable for drag chain, halogen-free, EMC prefered type, meter marking........................................................................
SHIPFLEX 340,cable for drag chain, halogen-free, EMC prefered type, meter marking........................................................................
SHIPFLEX 109,cable for drag chain, halogen-free, EMC prefered type (-C-Type), meter marking...........................................................
SHIPFLEX 109,cable for drag chain, halogen-free, EMC prefered type, meter marking........................................................................
SHIPFLEX 113,cable for drag chain, halogen-free, EMC prefered type, meter marking........................................................................
SHIPFLEX 121,cable for drag chain, halogen-free, EMC prefered type, meter marking........................................................................
EMC prefered type, meter marking

W 4
W 5
W 6
W 7
W 8
W 9

W 10
W 11
W 12
W 13
W 14
W 15
W 17
W 18
W 19
W 20
W 21
W 22
W 23

W3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Ships Power Cables MGSGO halogen-free, copper screened




Technical data

Cable structure

Properties

According to VG95218 part60, screened.


The core insulation continues to function
during a fire without the need for extra
flame-proof taping
Conductor operating temperature
max. +85 C
Nominal voltage U0/U 0,6/1 kV
Minimum bending radius
approx. 5x cable

Stranded copper conductors


Heat-resistant EPR-insulation 3GI3, to
DINVDE0207 part20
Cores stranded in layers with optimal
lay-length
Filling compound covering all cores
Foil screen
Plain copper braided screen
Polyester tape
Chloroprene based outer sheath 5GM3, to
DINVDE0207 part21
Jacket colour black

halogen-free and flame retardant


Colour code
1 core: black
2 cores: brown/blue
3 cores: brown/black/grey
4 cores: blue/brown/black/grey
Approved by
BWB (Bundesamt fr Wehrtechnik und
Beschaffung), i.e. German Federal Office
for Defence and Procurement


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.


Application
Halogen-free power cables for marine craft are used for permanent installation on ships in all rooms and open decks as control and power
cables.



Part no.
59270
59271
59272
59273
59274
59275
59276
59277
59278
59279
59280
59281
59282
59283
59284
59285
59286
59287
59288
59289
59290

No.cores x
cross-sec.
mm
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
2x1,5
2x2,5
2x4
2x6
2x10
2x16
2x25

Outer
Cop.
approx. mm weight
kg/km
7,5
81,0
8,4
104,0
9,5
149,0
10,0
214,0
12,0
311,0
13,0
416,0
15,0
572,0
17,0
779,0
19,5
1034,0
21,0
1316,0
23,0
1615,0
25,5
1968,0
29,0
2506,0
31,5
3345,0
11,5
105,0
12,4
132,0
13,4
170,0
14,7
217,0
16,2
307,0
19,0
471,0
22,5
670,0

Weight
approx.
kg/km
170,0
200,0
260,0
340,0
480,0
590,0
760,0
980,0
1300,0
1550,0
1850,0
2300,0
2950,0
3600,0
340,0
400,0
460,0
570,0
720,0
940,0
1300,0

AWG-No.
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
16
14
12
10
8
6
4


Part no.
59291
59292
59293
59294
59295
59296
59297
59298
59299
59300
59301
59302
59303
59304
59305
59306
59307
59308
59309
59310
59311

No.cores x
cross-sec.
mm
3x1,5
3x2,5
3x4
3x6
3x10
3x16
3x25
3x35
3x50
3x70
3x95
3x120
4x4
4x6
4x10
4x16
4x25
4x35
4x50
4x70
4x95

Outer
Cop.
approx. mm weight
kg/km
12,0
125,0
13,0
161,0
14,0
215,0
15,5
282,0
17,6
417,0
20,0
636,0
24,0
924,0
26,0
1233,0
30,0
1703,0
34,5
2413,0
39,7
3191,0
43,0
3975,0
15,2
284,0
17,0
371,0
19,4
545,0
22,0
796,0
26,4
1170,0
29,2
1578,0
33,5
2278,0
38,2
3090,0
44,2
4110,0

Weight
approx.
kg/km
380,0
440,0
520,0
640,0
840,0
1110,0
1610,0
2020,0
2610,0
3450,0
4710,0
5680,0
620,0
750,0
1010,0
1400,0
2000,0
2530,0
3280,0
4450,0
5930,0

AWG-No.
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
12
10
8
6
4
2
1
2/0
3/0

Dimensions and specifications may be changed without prior notice. (RW01)

W4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Light Marine Power Cables XLFMKK Cu-screened




Technical data

Cable structure

Properties

According to VG88778/66
Conductor operating temperature
max. +85 C
Min. installation temperature
-10 C
Nominal voltage 250 V
Minimum bending radius
approx. 5x cable

Stranded copper conductors to


DINVDE0295 cl.2, BS6360 cl.2 and
IEC60228 cl.2
PVC core insulation with polyamid coating
Cores laid up in pairs
Pairs copper screened
Separating foil
PVC inner sheath
Plain copper braided screen, waterproofed
PVC outer sheath, colour green

Colour code
All sizes are colour coded
Approved by
German ministry of defense

Application
For fixed installation on marine craft above and below deck.


Part no.
59336
59337

No.pairs x
cross-sec.
mm
2 x 2 x 0,75
4 x 2 x 0,75

Outer
Cop.
approx. mm weight
kg/km
16,0
160,0
18,1
277,0

Weight
approx.
kg/km
370,0
490,0

AWG-No.
18
18


Part no.
59338

No.pairs x
cross-sec.
mm
11 x 2 x 0,75

Outer
Cop.
approx. mm weight
kg/km
26,2
658,0

Weight
approx.
kg/km
1080,0

AWG-No.
18

Dimensions and specifications may be changed without prior notice. (RW01)

W5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Marine Power Cables LMGSGO halogen-free, Cu-screened




Technical data

Cable structure

Properties

According to VG95281 part61 screened.


No loss of insulation if directly exposed to
fire.
No special fire-proofed layer necessary
Conductor operating temperature
max. +85 C
Nominal voltage 500 V
Minimum bending radius
approx. 5x cable

Stranded copper conductor


Heat resistant EPR-insulation 3GI3, to
DINVDE0207 part20
Core stranded in layers with optimal
lay-length
Halogen-free inner filling sheath
Copper braided screening
Polyester foil taping
Chloroprene based outer sheath
Sheath colour black

Halogen-free and flame retardant


Colour code
2 cores: brown/blue
3 cores: brown/schwarz/grey
4 cores: blue/brown/black/grey
5 cores: blue/brown/black/grey/black
7-33 cores: all cores black, number coded,
core 1 placed centrally.
Approved by
BWB (Bundesamt fr Wehrtechnik und
Beschaffung), i.e. German Federal Office
for Defence and Procurement


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.


Application
For fixed installation on marine craft above and below deck.



Part no.
59360
59361
59362
59363
59364
59365
59366
59367
59368
59369
59370
59371
59372

No.cores x
cross-sec.
mm
2x1,5
3x1,5
4x1,5
5x1,5
7x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5
27x1,5
33x1,5

Outer
Cop.
approx. mm weight
kg/km
7,0
89,0
7,2
105,0
7,8
131,0
8,3
146,0
9,3
180,0
10,8
244,0
12,0
276,0
12,7
310,0
13,2
342,0
13,9
401,0
15,5
494,0
16,6
539,0
17,5
633,0

Weight
approx.
kg/km
110,0
140,0
170,0
180,0
230,0
310,0
350,0
400,0
450,0
510,0
620,0
680,0
810,0

AWG-No.
16
16
16
16
16
16
16
16
16
16
16
16
16


Part no.
59373
59374
59375
59376
59377

No.cores x
cross-sec.
mm
2x2,5
3x2,5
4x2,5
6x2,5
7x2,5

Outer
Cop.
approx. mm weight
kg/km
7,7
114,0
8,0
144,0
8,7
171,0
10,3
242,0
10,3
266,0

Weight
approx.
kg/km
160,0
190,0
230,0
300,0
320,0

AWG-No.
14
14
14
14
14

Dimensions and specifications may be changed without prior notice. (RW01)

W6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Ships Telephone Cables FMGCH 250 V (FMGCG*)


halogen-free according to DIN 89 159/99


Technical data

Cable structure

Properties

As per DIN89159/ edition 1998 and


IEC60092-375
Temperature range
max. +85 C conductor temperature
Nominal voltage 250 V
Insulation resistance
1400 MOhm x km
Minimum bending radius
approx. 5x cable

Stranded, bare copper conductors to


DINVDE0295 cl.2, BS6360 cl.2 and
IEC60228 cl.2
HEPR core insulation (Hard grade EPR)
Cores per pair, printed with numbers,
starting in center with number 1
Cores stranded in pairs with optimal
lay-length
Pairs stranded in layers with optimal
lay-length
Separator-foil
Bare copper braided screen
Separator-foil
Outher sheath, Polyolefin basis-compound
Sheath colour green

Flame retardant according to SOLAS


definition (according to IEC60332-3
categoryA)
Approved by
Association of German Electrical Engineers
Germanischer Lloyd, Lloyds Register of
Shipping, American Bureau of Shipping,
Det Norske Veritas, Bureau Veritas, Russian
Maritime Register of Shipping and Registro
Italiano Navale are in preparation


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application
For measurement, control , regulation , control and alarm systems ; radio , positioning and messaging systems . For fixed installation on
ships in rooms and on open decks.


Part no.
59138
59139
59140
59141

No.pairs x
cross-sec.
mm
1 x 2 x 0,75
2 x 2 x 0,75
4 x 2 x 0,75
7 x 2 x 0,75

Outer
Cop.
approx. mm weight
kg/km
8,5
62,0
9,0
87,0
13,0
153,0
15,5
230,0

Weight
approx.
kg/km
90,0
130,0
230,0
340,0

AWG-No.
18
18
18
18


Part no.
59142
59143
59144
59145

No.pairs x
cross-sec.
mm
10 x 2 x 0,75
14 x 2 x 0,75
19 x 2 x 0,75
24 x 2 x 0,75

Outer
Cop.
approx. mm weight
kg/km
18,5
319,0
21,0
445,0
24,0
525,0
27,0
663,0

Weight
approx.
kg/km
470,0
610,0
770,0
950,0

AWG-No.
18
18
18
18

Dimensions and specifications may be changed without prior notice. (RW01)

W7
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Marine Telecommunication Cables FMGSGO


halogen-free, Cu-screened


Technical data

Cable structure

Properties

According to VG 95218 part 62 with screen


and sustaining natural isolation in the case
of fire without a flame retardant barrier
Conductor operating temperature
max. +85 C
Nominal voltage 250 V
Minimum bending radius
approx. 5x cable

Bare copper conductor, stranded


Heat resistant EPR-insulation 3GI3, to
DINVDE0207 part20
To four wires twisted
Filling compound covering all cores,
halogen-free
Screening of copper braid
Sheet of polyester
Outer sheath of elastomer compound to
olefin - based copolymer
Sheath colour black

Halogen-free and flame retardant


Colour code
All sizes and dimensions are colour coded
Approved by
BWB (Bundesamt fr Wehrtechnik und
Beschaffung), i.e. German Federal Office
for Defence and Procurement

Application
For fixed installation on Navy ships in locations and on open decks.



Part no.
59380
59381
59382
59383

No.pairs x
cross-sec.
mm
2 x 2 x 0,75
4 x 2 x 0,75
6 x 2 x 0,75
8 x 2 x 0,75

Outer
Cop.
approx. mm weight
kg/km
6,7
89,0
9,6
142,0
10,8
189,0
11,9
225,0

Weight
approx.
kg/km
110,0
190,0
260,0
310,0

AWG-No.
18
18
18
18


Part no.
59384
59385
59386

No.pairs x
cross-sec.
mm
10 x 2 x 0,75
14 x 2 x 0,75
16 x 2 x 0,75

Outer
Cop.
approx. mm weight
kg/km
13,7
272,0
14,9
338,0
16,1
373,0

Weight
approx.
kg/km
380,0
465,0
520,0

AWG-No.
18
18
18

Dimensions and specifications may be changed without prior notice. (RW01)

W8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Marine Telecommunication Cables FMSGSGO


250 V with a single screen, higher cross-talk atttenuation, halogen-free


Technical data

Cable structure

According to VG95218 part63


Conductor operating temperature
max. +85 C
Min. installation temperature
-10 C
Nominal voltage 250 V
Minimum bending radius
approx. 3-5x cable

Properties

Bare copper conductor, stranded


Cross-linked polyolefin-insulation
Cores laid up in pairs
Separation foil
Each pair plain copper wire screened
Each pair with separation foil
Pairs laid up concentrically
Separation foil
Overall foil wrap
Plain, copper wire, braided screen
Separation foil
Elastomere based outer sheath
Sheath colour black

Oil resistant and flame retardant


Colour code for cores
Pair/counting pair: black/blue
Pair/counting direction pair: black/brown
Subsequent pairs: black/grey
Approved by
BWB (Bundesamt fr Wehrtechnik und
Beschaffung), i.e. German Federal Office
for Defence and Procurement


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application
For fixed installation on marine craft above and below deck.


Part no.
59150
59151
59152
59153

No.pairs x
cross-sec.
mm
2 x 2 x 0,75
4 x 2 x 0,75
7 x 2 x 0,75
11 x 2 x 0,75

Outer
Cop.
approx. mm weight
kg/km
11,1
149,0
12,9
277,0
14,9
489,0
19,6
658,0

Weight
approx.
kg/km
220,0
340,0
500,0
780,0

AWG-No.
18
18
18
18


Part no.
59154
59155
59156

No.pairs x
cross-sec.
mm
14 x 2 x 0,75
19 x 2 x 0,75
24 x 2 x 0,75

Outer
Cop.
approx. mm weight
kg/km
20,8
731,0
23,4
951,0
25,3
1181,0

Weight
approx.
kg/km
950,0
1300,0
1600,0

AWG-No.
18
18
18

Dimensions and specifications may be changed without prior notice. (RW01)

W9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Light Marine Telekommunication Cables


LFMGSSGO halogen-free, 2x Cu-screened


Technical data

Cable structure

Properties

According to VG95218 part64,


2x copper screening.
No loss of insulation if directly exposed to
open flame.
No special flame proof layer neccessary
Conductor operating temperature
max. +85 C
Min. installation temperature
-10 C
Nominal voltage 250 V
Minimum bending radius
approx. 6x cable

Stranded (7) tinned copper conductor to


DINVDE0295 cl.2, BS6360 cl.2 and
IEC60228 cl.2
Cross-linked polyolefin-insulation
Core stranded to pairs with optimal
lay-length
Overall halogen-free inner filling
Tinned copper, braided double screening
Polyester foil taping
Elastomere based outer sheath
Sheath colour black

Oil resistant and flame retardant


Colour code for cores
Pair/counting pair: black/blue
Pair/counting direction pair: black/brown
Subsequent pairs: black/grey
Approved by
BWB (Bundesamt fr Wehrtechnik und
Beschaffung), i.e. German Federal Office
for Defence and Procurement

Application
For fixed installation on marine craft above and below decks.



Part no.
59390
59391
59392

No.pairs x
cross-sec.
mm
2 x 2 x 0,4
4 x 2 x 0,4
7 x 2 x 0,4

Outer
Cop.
approx. mm weight
kg/km
8,0
60,0
10,5
95,0
12,5
146,0

Weight
approx.
kg/km
95,0
145,0
220,0


Part no.

59393
59394
59395

No.pairs x
cross-sec.
mm
12 x 2 x 0,4
19 x 2 x 0,4
27 x 2 x 0,4

Outer
Cop.
approx. mm weight
kg/km
15,5
235,0
18,0
320,0
20,0
414,0

Weight
approx.
kg/km
320,0
415,0
540,0

Dimensions and specifications may be changed without prior notice. (RW01)

W 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Light Marine Telecommunication Cables


LFMSGSSGO halogen-free, 2x Cu-screened


Technical data

Cable structure

Properties

According to VG95218 part66,


2x copper screening with improved
cross-talk protection.
No loss of insulation if directly exposed to
open flame.
No special flame proof layer necessary
Conductor operating temperature
max. +85 C
Min. installation temperature
-10 C
Nominal voltage 250 V
Minimum bending radius
approx. 6x cable

Stranded (7) tinned copper conductor


Cross-linked polyolefin-insulation
Core stranded to pairs with optimal
lay-length
Tinned copper, braided screening over each
pair
Polyester foil seperator
Overall polyester taped inner covering
Tinned copper, braided overall screen
Halogen-free insulating layer
Overall tinned copper, braided screen
Polyester foil separator
Elastomere based outer sheath
Sheath colour black

Oil resistant and flame retardant


Colour code
All sizes and dimensions are colour coded
Approved by
BWB (Bundesamt fr Wehrtechnik und
Beschaffung), i.e. German Federal Office
for Defence and Procurement

Application
For fixed installation on marine craft above and below decks.


Part no.
59396

No.pairs x
cross-sec.
mm
5 x 3 x 0,4

Outer
Cop.
approx. mm weight
kg/km
16,0
248,0

Weight
approx.
kg/km
420,0


Part no.

59397

No.pairs x
cross-sec.
mm
12 x 3 x 0,4

Outer
Cop.
approx. mm weight
kg/km
23,0
500,0

Weight
approx.
kg/km
740,0

Dimensions and specifications may be changed without prior notice. (RW01)

W 11
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Ships Wiring Cables-SY single cores




Technical data

Cable structure

Properties

Special PVC single cores according to


DINVDE0250
Temperature range
flexing +5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage 250 V
Test voltage 1500 V
Minimum bending radius
approx. 7,5x cable

Fine wire stranded, plain copper


conductors according to DINVDE0295 cl.5,
BS6360 cl.5 and IEC60228 cl.5
PVC core insulation
Tinned steel-wire braided screening
PVC outer sheath (RAL7001)
Sheath colour black

Flame resistant and self-extinguishing as


per VDE0472, part804, testB and
IEC60332-1
Oil resistant according DINVDE0250
Approved by
Germanischer Lloyd

Application
A connection and a connection cable for measuring and control devices for communication systems , production lines , conveyor systems
for fixed and variable connection in humid, wet and dry areas. These PVC single cores are also suitable for use in ship building.



Part no.
59450
59451
59452
59453

No.cores x
cross-sec.
mm
1x6
1x10
1x16
1x25

Outer
Cop.
approx. mm weight
kg/km
8,3
57,4
10,3
95,8
10,3
153,4
13,7
239,5

Weight
approx.
kg/km
148,0
221,0
293,0
447,0

AWG-No.
10
8
6
4


Part no.
59454
59455
59456
59457

No.cores x
cross-sec.
mm
1x35
1x50
1x70
1x95

Outer
Cop.
approx. mm weight
kg/km
15,2
335,0
18,1
479,5
21,1
671,0
22,8
910,0

Weight
approx.
kg/km
565,0
788,0
1061,0
1355,0

AWG-No.
2
1
2/0
3/0

Dimensions and specifications may be changed without prior notice. (RW01)

W 12
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Ships Wiring Cables-SY stranded type




Technical data

Cable structure

Properties

Special PVC cables


Temperature range
flexing +5 C to +70 C
fixed installation -40 C to +70 C
Nominal voltage 250 V
Test voltage 3000 V
Minimum bending radius
approx. 7,5x cable

Fine stranded, plain copper conductors


according to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
PVC-based core insulation YI2 according to
DINVDE0207
Cores colour coded to DINVDE0293 or
black cores with continuous white
numbering
Core stranded in layers with optimal
lay-length
PVC inner sheath
Galvanized steel-wire braided overall
screening
Outer sheath according to DINVDE0207
part5
Sheath colour grey (RAL7001)

Extensively oil resistant.


Chemical Resistance - see table Technical
Informations
Flame resistant and self-extinguishing as
per VDE0472, part804, testB and
IEC60332-1
Approved by
Germanischer Lloyd


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application
Ideally suited for for fixed installation but also for the variable use of manufacturing lines, machine tools , conveyor systems and robotic
assembly lines. A line that can also be used in shipbuilding. Thegalvanized steel braid protects against mechanical stress and simultaneously
effective against electrical interference .


Part no.
59460
59461
59462
59463
59464
59465

No.cores x
cross-sec.
mm
2x1,5
3x1,5
4x1,5
5x1,5
7x1,5
3x2,5

Outer
Cop.
approx. mm weight
kg/km
9,7
28,7
10,1
43,1
10,8
57,5
11,6
71,9
13,3
100,6
11,6
72,1

Weight
approx.
kg/km
146,0
166,0
198,0
230,0
299,0
231,0

AWG-No.
16
16
16
16
16
14


Part no.
59466
59467
59468
59469
59470
59471

No.cores x
cross-sec.
mm
4x2,5
5x2,5
4x4
5x4
4x6
5x6

Outer
Cop.
approx. mm weight
kg/km
13,3
95,8
14,3
120,0
16,2
153,5
17,5
193,0
18,4
230,3
19,7
288,0

Weight
approx.
kg/km
298,0
355,0
358,0
535,0
595,0
714,0

AWG-No.
14
14
12
12
10
10

Dimensions and specifications may be changed without prior notice. (RW01)

W 13
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Ships Power Cables MPRX 0,6/1kV


according to IEC 60092-353, halogen-free


Technical data

Cable structure

Properties

As per IEC60092-353
Temperature range
max. +85 C conductor temperature
Min. installation temperature
-10 C
Nominal voltage
U0/U 0,6/1 kV
Minimum bending radius
approx. 4x cable

Stranded, bare copper conductors to


DINVDE0295 cl.2, BS6360 cl.2 and
IEC60228 cl.2
Core insulation of cross-linked polyethylene
Cores stranded in layers with optimal
lay-length
Outer sheath, Polyolefin basis-compound
Jacket colour black


Colour code
1 core: black
2 cores: brown/blue
3 cores: brown/black/grey
4 cores: blue/brown/black/grey
5 to 24 core cable: all cores black coloured,
printed with numbers, starting in center
with number 1
Approved by
Germanischer Lloyd, Lloyds Register of
Shipping, American Bureau of Shipping,
Det Norske Veritas, Bureau Veritas, Russian
Maritime Register of Shipping and Registro
Italiano Navale
Tests
Flame-test to VDE0472 part804, test
methodC, IEC60332-3 cat.A and
IEEE45-18.13
Smoke density to IEC61034 Halogen-free
to 60754-1
Corrosiveness of combustion gases to
IEC60754-2
Flame retardant according to SOLAS
definition (according to IEC60332-3
categoryA and IEEE45-18.13)


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.


Application
For fixed installation on ships and offshore-units in all locations below the upper metallic deck.
Particularly suitable for installation on passenger ships.



Part no.
59654
59655
59656
59657
59658
59659
59660
59661
59662
59663
59664
59665
59666
59667
59668
59669
59670
59671
59672
59673
59674
59675
59676
59677
59678
59679
59680

No.cores x
cross-sec.
mm
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
2x1,5
2x2,5
2x4
2x6
2x10
2x16
2x25
3x1,5
3x2,5
3x4
3x6
3x10
3x16

Outer
Cop.
approx. mm weight
kg/km
27,5
38,0
7,0
58,0
8,0
96,0
9,0
154,0
10,0
240,0
12,5
336,0
14,5
480,0
18,0
672,0
8,0
912,0
9,0
1152,0
10,0
1440,0
11,0
1776,0
13,0
2304,0
15,5
2880,0
19,0
29,0
20,5
48,0
24,0
77,0
26,5
115,0
30,5
192,0
33,5
307,0
8,5
480,0
10,0
43,0
11,0
72,0
12,0
115,0
14,5
173,0
17,0
288,0
21,0
461,0

Weight
approx.
kg/km
70,0
95,0
140,0
200,0
320,0
420,0
560,0
780,0
1030,0
1290,0
1590,0
1960,0
2560,0
3200,0
80,0
105,0
145,0
190,0
290,0
430,0
680,0
100,0
140,0
190,0
260,0
410,0
600,0

AWG-No.
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
16
14
12
10
8
6
4
16
14
12
10
8
6


Part no.
59681
59682
59683
59684
59685
59686
59687
59688
59689
59690
59691
59692
59693
59694
59695
59696
59697
59698
59699
59700
59701
59702
59703
59704
59705
59706

No.cores x
cross-sec.
mm
3x25
3x35
3x50
3x70
3x95
3x120
4x1,5
4x2,5
4x4
4x6
4x10
4x16
4x25
4x35
4x50
4x70
4x95
5x1,5
5x2,5
7x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5

Outer
Cop.
approx. mm weight
kg/km
23,0
720,0
27,0
1008,0
31,0
1440,0
35,5
2016,0
9,5
2736,0
10,5
3456,0
10,5
58,0
13,5
96,0
14,0
154,0
14,5
230,0
16,5
384,0
16,5
614,0
19,5
960,0
23,9
1344,0
27,8
1920,0
32,9
2688,0
36,1
3648,0
10,1
72,0
11,2
120,0
11,0
101,0
14,1
144,0
14,7
173,0
15,5
202,0
16,3
230,0
17,4
274,0
20,5
346,0

Weight
approx.
kg/km
970,0
1290,0
1720,0
2450,0
3305,0
4140,0
130,0
180,0
245,0
345,0
535,0
795,0
1300,0
1725,0
2310,0
3275,0
4445,0
165,0
225,0
205,0
290,0
330,0
375,0
440,0
500,0
630,0

AWG-No.
4
2
1
2/0
3/0
4/0
16
14
12
10
8
6
4
2
1
2/0
3/0
16
14
16
16
16
16
16
16
16

Dimensions and specifications may be changed without prior notice. (RW01)

W 14
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Ships Power Cables MPRXCX 0,6/1kV


according to IEC 60092-353, halogen-free


Technical data

Cable structure

Properties

As per IEC60092-353
Temperature range
max. +85 C conductor temperature
Min. installation temperature
-10 C
Nominal voltage
U0/U 0,6/1 kV
Minimum bending radius
approx. 4x cable
Tests
Flame-test to VDE0472 part804, test
methodC, IEC60332-3 cat.A and
IEEE45-18.13
Smoke density to IEC61034
Halogen-free to 60754-1
Corrosiveness of combustion gases to
IEC60754-2

Stranded, bare copper conductors to


DINVDE0295 cl.2, BS6360 cl.2 and
IEC60228 cl.2
Core insulation of cross-linked polyethylene
Cores stranded in layers with optimal
lay-length
Cores wrapping with fail
Copper screened braiding
Outer sheath, Polyolefin basis-compound
Jacket colour black


Colour code
1 core: black
2 cores: brown/blue
3 cores: brown/black/grey
4 cores: blue/brown/black/grey
5- to 24 core cable: all cores black coloured,
printed with numbers, starting in center
with number 1
Approved by
Germanischer Lloyd, Lloyds Register of
Shipping, American Bureau of Shipping,
Det Norske Veritas, Bureau Veritas,Russian
Maritime Register of Shipping and Registro
Italiano Navale
Flame retardant according to SOLAS
definition (according to IEC60332-3
categoryA and IEEE45-18.13)


Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.
3-core cables with green-yellow marked
core and/or as MPRXCX 331 (insulation
integrity to IEC60331) also available.


Application
For fixed installation on ships and offshore-units in all locations below the upper metallic deck. Particularly suitable for installation on
passenger ships. The good screening qualities of the copper braid also reduce radio interferences and electrical influences to electronic
installations.


Part no.
59707
59708
59709
59710
59711
59712
59713
59714
59715
59716
59717
59718
59719
59720
59721
59722
59723
59724
59725
59726
59727
59728
59729
59730
59731
59732
59733

No.cores x
cross-sec.
mm
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
2x1,5
2x2,5
2x4
2x6
2x10
2x16
2x25
3x1,5
3x2,5
3x4
3x6
3x10
3x16

Outer
Cop.
approx. mm weight
kg/km
7,3
81,0
7,8
104,0
8,9
149,0
9,8
214,0
11,7
311,0
12,7
416,0
14,8
572,0
16,9
779,0
18,7
1034,0
20,6
1316,0
22,7
1615,0
24,9
1968,0
27,2
2506,0
30,4
3345,0
3,9
105,0
10,2
132,0
11,4
170,0
12,6
217,0
14,8
400,0
16,9
471,0
20,4
670,0
9,9
125,0
10,8
161,0
12,0
215,0
13,2
282,0
15,7
417,0
18,0
636,0

Weight
approx.
kg/km
105,0
130,0
180,0
250,0
380,0
480,0
660,0
900,0
1170,0
1410,0
1750,0
2160,0
2770,0
3440,0
130,0
160,0
205,0
290,0
307,0
560,0
840,0
160,0
200,0
250,0
360,0
520,0
750,0

AWG-No.
12
10
8
6
4
2
1
2/0
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
16
14
12
10
8
6
4
16
14
12
10
8
6


Part no.
59734
59735
59736
59737
59738
59739
59740
59741
59742
59743
59744
59745
59746
59747
59748
59749
59750
59751
59752
59753
59754
59755
59756
59757
59758
59759

No.cores x
cross-sec.
mm
3x25
3x35
3x50
3x70
3x95
3x120
4x1,5
4x2,5
4x4
4x6
4x10
4x16
4x25
4x35
4x50
4x70
4x95
5x1,5
5x2,5
7x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5

Outer
Cop.
approx. mm weight
kg/km
21,7
924,0
23,1
1233,0
26,5
1703,0
29,1
2413,0
32,9
3192,0
36,7
3975,0
10,6
147,0
11,9
190,0
13,0
284,0
14,6
371,0
17,3
545,0
19,8
796,0
23,9
1170,0
25,7
1578,0
29,6
2278,0
33,7
3090,0
38,3
4110,0
11,7
171,0
12,8
220,0
12,5
209,0
16,0
318,0
16,6
353,0
17,4
394,0
18,2
432,0
19,3
486,0
22,4
601,0

Weight
approx.
kg/km
950,0
1470,0
1870,0
2650,0
3500,0
4300,0
200,0
240,0
350,0
450,0
670,0
950,0
1470,0
1930,0
2500,0
3550,0
4600,0
225,0
330,0
310,0
400,0
440,0
500,0
550,0
620,0
770,0

AWG-No.
4
2
1
2/0
3/0
4/0
16
14
12
10
8
6
4
2
1
2/0
3/0
16
14
16
16
16
16
16
16
16

Dimensions and specifications may be changed without prior notice. (RW01)

W 15
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SHIPFLEX
SHIPFLEX
SHIPFLEX
SHIPFLEX
SHIPFLEX
SHIPFLEX
SHIPFLEX

512
330
340
109
109
113
121

Photo: fotolia.com

Lloyd`s Register

W 16
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SHIPFLEX 512 cable for drag chain, halogen-free,


EMC prefered type, meter marking


Technical data

Cable structure

Properties

Special screened drag chain cable


UL-Style 20234
Temperature range
flexing -40 C to +80 C
fixed -40 C to +80 C
Installation temperature
minimum -25 C
Nominal voltage
UL 1000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
for permanent bending
7,5x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, ultra-fine wire conductors


acc. to DINVDE0295 cl.6, BS 6360 cl. 6, IEC
60228 cl.6
Special core insulation
Black cores with continuous white
numbering
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
selected lay-length
Braided screening of tinned copper wires,
coverage approx. 85 %, optional aluminium
foil under the braid 
Full polyurethane outer sheat to
ULstd.1581 Tab.50227
Sheath colourgrey (RAL 7001)
with meter marking

Flame retardant according to VDE


0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Halogen free to VDE 0482 part 267/ DIN EN
50267-2-1/ IEC 60754-1 (conforms to DIN
VDE 0472 part 815)
Oil resistant to IEC 60092-350, appendix F
Behaviour at low temperature at -40 C to
IEC 60092-350, appendix E
Weather, ozon and UV-resistant
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers


Application
HELUKABEL SHIPFLEX512 is a new developed and successfully tested screened special drag chain cable which meets the requirements of
the strict standards for application in offshore-areas. For this two - line standard there is a Lloyds Register approval .
The outer sheath insulation of non-adhesive Polyurethan allows the application in extremely oily and rough environmental conditions.
For applications which go beyond standard solutions we recommend that you fill out our especially developed questionnaire for drag chains.
Before installation in cable drag chains please read the installation instructions.
EMC = Electromagnetic compatibility
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
19864
19865
19866
19867
19868
19869
19870
19871
19872
19873
19874
19875
19876
19877
19878
19879
19880
19881
19882
19883
19884
19885
19886
19887
19888
19889
19890
19891
19892
19893
19894
19895

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5
36G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75
36G0,75
2x1
3G1
4G1
5G1
7G1
12G1
18G1
25G1
36G1
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5

AWG-No. Outer
approx.
mm
20
6,3
20
6,5
20
7,0
20
7,5
20
8,5
20
10,0
20
11,5
20
13,5
20
15,2
19
7,0
19
7,2
19
7,8
19
8,5
19
9,6
19
11,5
19
13,0
19
15,8
19
17,5
18
7,4
18
7,7
18
8,5
18
9,0
18
10,4
18
12,4
18
14,3
18
17,0
18
19,0
16
8,0
16
8,3
16
9,2
16
10,0
16
11,6

Cop.
weight
kg/km
35,0
42,0
47,0
56,0
69,0
108,0
145,0
240,0
318,0
40,0
52,0
60,0
71,0
91,0
142,0
212,0
281,0
350,0
50,0
60,0
71,0
88,0
111,0
184,0
260,0
349,0
510,0
63,0
80,0
97,0
119,0
147,0

Weight
approx.
kg/km
50,0
60,0
64,0
79,0
101,0
164,0
227,0
331,0
457,0
65,0
71,0
82,0
97,0
141,0
217,0
304,0
420,0
535,0
69,0
84,0
104,0
130,0
160,0
270,0
391,0
547,0
790,0
90,0
109,0
132,0
169,0
219,0


Part no.
19896
19897
19898
19899
19900
19901
19902
19903
19904
19905
19906
19907
19908
19909
19910
19911
19912
19913
19914
19915
19916
19917
19918
19919
19920
19921
19922
19923
19924
19925
19926

No.cores x
cross-sec.
mm
12G1,5
18G1,5
25G1,5
36G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5
36G2,5
3G4
4G4
5G4
6G4
7G4
3G6
4G6
5G6
6G6
7G6
3G10
4G10
5G10
6G10
7G10
3G16
4G16
5G16

AWG-No. Outer
approx.
mm
16
13,8
16
16,2
16
19,0
16
21,5
14
9,5
14
10,3
14
11,3
14
12,4
14
14,4
14
17,5
14
20,3
14
24,2
14
27,2
12
11,5
12
12,4
12
13,5
12
15,2
12
16,3
10
13,5
10
15,2
10
16,5
10
17,8
10
19,5
8
17,1
8
19,0
8
20,7
8
22,0
8
24,0
6
19,8
6
21,8
6
24,0

Cop.
weight
kg/km
267,0
374,0
526,0
702,0
96,0
144,0
149,0
181,0
255,0
441,0
604,0
793,0
1034,0
174,0
230,0
274,0
295,0
316,0
240,0
305,0
442,0
471,0
505,0
367,0
549,0
607,0
711,0
820,0
692,0
840,0
1050,0

Weight
approx.
kg/km
363,0
496,0
724,0
1190,0
136,0
179,0
201,0
232,0
357,0
586,0
1064,0
1411,0
1623,0
257,0
324,0
401,0
456,0
511,0
343,0
427,0
562,0
628,0
692,0
731,0
992,0
1014,0
1241,0
1491,0
1004,0
1296,0
1658,0

Dimensions and specifications may be changed without prior notice. (RC02)

W 17
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SHIPFLEX 330 cable for drag chain, halogen-free,


EMC prefered type, meter marking


Technical data

Cable structure

Properties

Special screened drag chain cable


UL-Style 20233
Temperature range
flexing -40 C to +80 C
fixed -40 C to +80 C
Installation temperature
minimum -25 C
Nominal voltage
VDE U0/U 300/500 V
UL 300 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
for permanent bending 7,5x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper conductor, extra fine wire to


DINVDE0295 cl.6, BS6360 cl.6 and IEC
60228 cl. 6
Special core insulation
Colored coresto DIN47100
Cores stranded in layers with optimal
lay-length
Core wrapping between the layers of
stranding
Braided screening of tinned copper wires,
coverage approx. 85 % optional aluminium
foil under the screen
Full polyurethane outer sheat to
ULstd.1581 Tab.50227
Sheath colour grey (RAL7001)
with meter marking

Flame retardant according to VDE


0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Halogen free to VDE 0482 part 267/ DIN EN
50267-2-1/ IEC 60754-1 (conforms to DIN
VDE 0472 part 815)
Oil resistant to IEC 60092-350, appendix F
Behaviour at low temperature at -40 to
IEC 60092-350, appendix E
Weather, ozon and UV-resistant
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Application
HELUKABEL SHIPFLEX330 is a new developed and successfully tested special drag chain cable with overall screening which meets the
requirements of the strict standards for application in offshore-areas. For this two-line standard there is a Lloyds Register approval. The
outer sheath insulation of non-adhesive Polyurethan allows the application in extremely oily and rough environmental conditions.For
applications which go beyond standard solutions we recommend that you fill out our especially developed questionnaire for drag chains.Before
installation in cable drag chains please read the installation instructions.
EMC=Electromagnetic compatibility
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no.
19846
19847
19848
19849
19850
19851
19852
19853
19854

No.cores x
cross-sec.
mm
2x0,25
3x0,25
4x0,25
5x0,25
7x0,25
12x0,25
18x0,25
25x0,25
36x0,25

AWG-No. Outer
approx.
mm
24
5,0
24
5,2
24
5,5
24
5,8
24
6,7
24
8,0
24
9,0
24
10,8
24
11,5

Cop.
weight
kg/km
14,9
18,8
21,3
31,0
39,6
59,1
78,4
101,0
126,4

Weight
approx.
kg/km
38,0
44,0
51,0
68,0
82,0
124,0
150,0
204,0
230,0


Part no.
19855
19856
19857
19858
19859
19860
19861
19862
19863

No.cores x
cross-sec.
mm
2x0,34
3x0,34
4x0,34
5x0,34
7x0,34
12x0,34
18x0,34
25x0,34
36x0,34

AWG-No. Outer
approx.
mm
22
5,2
22
5,5
22
5,8
22
6,5
22
7,2
22
8,5
22
10,0
22
12,0
22
13,0

Cop.
weight
kg/km
18,1
28,7
35,7
39,1
52,7
76,4
99,7
155,0
188,0

Weight
approx.
kg/km
45,0
60,0
76,0
82,0
110,0
166,0
216,0
305,0
340,0

Dimensions and specifications may be changed without prior notice. (RN05)

W 18
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SHIPFLEX 340 cable for drag chain, halogen-free,


EMC prefered type, meter marking


Technical data

Cable structure

Properties

Special screeneddrag chain cable, stranded


in pairs
UL-Style 20233
Temperature range
flexing -40 C to +80 C
fixed -40 C to +80 C
Installation temperature
minimum -25 C
Nominal voltage
VDE U0/U 300/500 V
UL 300 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius for permanent
bending
7,5x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper conductor, extrafine wire to


DINVDE0295 cl.6, BS6360 cl.6, IEC 60228
cl. 6
Special coreinsulation
Colour coded to DIN47100
Cores stranded in pairs, pairs stranded
torsion-free in layers with optimal
lay-length
Core wrapping between the layers of
stranding
Braided screening of tinned copper wires,
coverage approx. 85 %
optional aluminium foil under the screen
Full polyurethane outer sheat to
ULstd.1581 Tab.50227
Sheath colour grey (RAL7001)
with meter marking

Flame retardant according to VDE


0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Halogen free to VDE 0482 part 267/ DIN EN
50267-2-1/ IEC 60754-1 (conforms to DIN
VDE 0472 part 815)
Oil resistant to IEC 60092-350, appendix F
Behaviour at low temperature at -40 C to
IEC 60092-350, appendix E
Weather, ozon and UV-resistant
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Application
HELUKABEL SHIPFLEX340 is a new developed and successfully tested special drag chain cable with overall screening which meets the
requirements of the strict standards for application in offshore-areas.
For this two - line standard there is a Lloyds Register approval .
The outer sheath insulation of non-adhesive Polyurethan allows the application in extremely oily and rough environmental conditions.
For applications which go beyond standard solutions we recommend that you fill out our especially developed questionnaire for drag chains.
Before installation in cable drag chains please read the installation instructions.
EMC=Electromagnetic compatibility
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.pairs x


no.cores x
cross-sec.
mm
19927
2x2x0,25
19928
3x2x0,25
19929
4x2x0,25
19930
5x2x0,25
19931
6x2x0,25
19932
7x2x0,25
19933
12x2x0,25
19934
18x2x0,25
19935
25x2x0,25
19936
2x2x0,34
19937
3x2x0,34
19938
4x2x0,34
19939
5x2x0,34
19940
6x2x0,34
19941
7x2x0,34
19942
12x2x0,34
19943
18x2x0,34
19944
25x2x0,34
19945
2x2x0,5
19946
3x2x0,5
19947
4x2x0,5

AWG-No.

24
24
24
24
24
24
24
24
24
22
22
22
22
22
22
22
22
22
20
20
20

Outer
Cop.
approx. mm weight
kg/km
6,8
7,1
7,5
8,0
8,5
9,2
11,4
13,5
15,0
7,4
7,7
8,4
9,1
10,0
10,5
12,2
14,4
16,5
8,0
8,4
9,0

32,0
38,0
43,0
51,0
72,0
75,0
117,0
148,0
233,0
41,0
52,0
59,0
67,0
86,0
94,0
122,0
197,0
238,0
53,0
73,0
77,0

Weight
approx.
kg/km
60,0
70,0
82,0
99,0
126,0
135,0
189,0
248,0
343,0
81,0
100,0
119,0
135,0
163,0
170,0
220,0
277,0
400,0
100,0
131,0
149,0


Part no. No.pairs x
no.cores x
cross-sec.
mm
19948
5x2x0,5
19949
6x2x0,5
19950
7x2x0,5
19951
12x2x0,5
19952
18x2x0,5
19953
25x2x0,5
19954
2x2x0,75
19955
3x2x0,75
19956
4x2x0,75
19957
5x2x0,75
19958
6x2x0,75
19959
7x2x0,75
19960
12x2x0,75
19961
18x2x0,75
19962
2x2x1
19963
3x2x1
19964
4x2x1
19965
5x2x1
19966
6x2x1
19967
7x2x1
19968
12x2x1

AWG-No.

20
20
20
20
20
20
19
19
19
19
19
19
19
19
18
18
18
18
18
18
18

Outer
Cop.
approx. mm weight
kg/km
9,7
10,6
11,5
13,5
15,7
18,2
9,0
9,5
10,3
11,2
12,1
13,0
16,0
18,0
10,0
10,4
11,8
12,6
13,6
14,8
18,0

86,0
103,0
117,0
199,0
265,0
344,0
61,0
87,0
95,0
115,0
137,0
153,0
261,0
374,0
73,0
94,0
118,0
139,0
188,0
204,0
324,0

Weight
approx.
kg/km
160,0
170,0
191,0
361,0
427,0
740,0
102,0
144,0
160,0
193,0
218,0
298,0
406,0
519,0
120,0
161,0
184,0
217,0
295,0
311,0
602,0

Dimensions and specifications may be changed without prior notice. (RN05)

W 19
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SHIPFLEX 109 cable for drag chain, halogen-free,


EMC prefered type (-C-Type), meter marking


Technical data

Cable structure

Properties

Special drag chain cable


UL-Style 20234
Temperature range
flexing -40 C to +80 C
fixed -40 C to +80 C
Installation temperature
minimum -25 C
Nominal voltage
to VDE U0/U 0,6/1 kV
UL 1000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius for permanent
bending
7,5x cable 
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, ultra-fine wire acc. to


DINVDE0295 cl.6, BS 6360 cl. 6, IEC60228
cl.6
Special core insulation
Colour black or green-yellow
Full polyurethane outer sheat to
ULstd.1581 Tab.50227
Sheath colour orange (RAL 2003)
Screen Type
screen off tinned Cu-braid, coverage
approx. 85%
with meter marking

Flame retardant according to VDE


0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Halogen free to VDE 0482 part 267/ DIN EN
50267-2-1/ IEC 60754-1 (conforms to DIN
VDE 0472 part 815)
Oil resistant to IEC 60092-350, appendixF
Behaviour at low temperature at -40 C to
IEC 60092-350, appendixE
Weather, ozon and UV-resistant
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Application
HELUKABEL SHIPFLEX109 Single is a new developed and successfully tested non screened special drag chain cable which meets the
requirements of the strict standards for application in offshore-areas. For this two - line standard there is a Lloyds Register approval .
The outer sheath insulation of non-adhesive Polyurethan allows the application in extremely oily and rough environmental conditions.
For applications which go beyond standard solutions we recommend that you fill out our especially developed questionnaire for drag chains.
Before installation in cable drag chains please read the installation instructions.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


SHIPFLEX 109 unscreened


Part no. No.cores x
cross-sec.
mm
21388
1x6
21374
1G6
21389
1x10
21375
1G10
21390
1x16
21376
1G16
21391
1x25
21377
1G25
21392
1x35
21378
1G35
21393
1x50
21379
1G50
21394
1x70
21380
1G70
21395
1x95
21381
1G95
21396
1x120
21382
1G120
21397
1x150
21383
1G150
21398
1x185
21384
1G185
21399
1x240
21404
1G240

AWG-No. Core
colour
10
10
8
8
6
6
4
4
2
2
1
1
2/0
2/0
3/0
3/0
4/0
4/0
300 kcmil
300 kcmil
350 kcmil
350 kcmil
500 kcmil
500 kcmil

Outer
approx.
mm
black
6,9
Green-yellow
6,9
black
8,3
Green-yellow
8,3
black
9,5
Green-yellow
9,5
black
11,3
Green-yellow 11,3
black
12,7
Green-yellow 12,7
black
15,0
Green-yellow 15,0
black
16,3
Green-yellow 16,3
black
18,8
Green-yellow 18,8
black
20,9
Green-yellow 20,9
black
23,2
Green-yellow 23,2
black
25,7
Green-yellow 25,7
black
28,2
Green-yellow 28,2

Cop.
weight
kg/km
58,0
58,0
96,0
96,0
154,0
154,0
240,0
240,0
336,0
336,0
480,0
480,0
672,0
672,0
912,0
912,0
1152,0
1152,0
1440,0
1440,0
1776,0
1776,0
2304,0
2304,0

Weight
approx.
kg/km
108,0
108,0
170,0
170,0
240,0
240,0
370,0
370,0
490,0
490,0
665,0
665,0
910,0
910,0
1190,0
1190,0
1530,0
1530,0
1720,0
1720,0
2280,0
2280,0
2895,0
2895,0

SHIPFLEX 109 screened


Part no. No.cores x
cross-sec.
mm
19798
1x6
21330
1G6
19799
1x10
21331
1G10
19800
1x16
21332
1G16
19801
1x25
21333
1G25
19802
1x35
21334
1G35
19803
1x50
21335
1G50
19804
1x70
21336
1G70
19805
1x95
21337
1G95
19806
1x120
21338
1G120
19807
1x150
21339
1G150
19808
1x185
21406
1G185
19809
1x240
21410
1G240

AWG-No. Core
colour
10
10
8
8
6
6
4
4
2
2
1
1
2/0
2/0
3/0
3/0
4/0
4/0
300 kcmil
300 kcmil
350 kcmil
350 kcmil
500 kcmil
500 kcmil

Outer
approx.
mm
black
7,6
Green-yellow
7,6
black
9,1
Green-yellow
9,1
black
10,2
Green-yellow 10,2
black
12,1
Green-yellow 12,1
black
13,5
Green-yellow 13,5
black
15,9
Green-yellow 15,9
black
17,3
Green-yellow 17,3
black
19,5
Green-yellow 19,5
black
21,8
Green-yellow 21,8
black
24,1
Green-yellow 24,1
black
26,5
Green-yellow 29,2
black
29,2
Green-yellow 29,2

Cop.
weight
kg/km
72,0
72,0
130,0
130,0
190,0
190,0
260,0
260,0
405,0
405,0
560,0
560,0
780,0
780,0
1030,0
1030,0
1285,0
1285,0
1430,0
1430,0
1940,0
1940,0
2530,0
2530,0

Weight
approx.
kg/km
140,0
140,0
225,0
225,0
295,0
295,0
415,0
415,0
610,0
610,0
817,0
817,0
1065,0
1065,0
1340,0
1340,0
1735,0
1735,0
1910,0
1910,0
2610,0
2610,0
3274,0
3274,0

Dimensions and specifications may be changed without prior notice. (RN07)

W 20
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SHIPFLEX 109 cable for drag chain, halogen-free,


EMC prefered type, meter marking


Technical data

Cable structure

Properties

Special screened drag chain cable


UL-Style 20234
Temperature range
flexing -40 C to +80 C
fixed -40 C to +80 C
Installation temperature
minimum -25 C
Nominal voltage
to VDE U0/U 0,6/1 kV
UL 1000 V
Insulation resistance
min. 200 MOhm x km
Minimum bending radius for permanent
bending
7,5x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, ultra-fine wire acc. to


DINVDE0295 cl.6, BS 6360 cl. 6, IEC60228
cl.6
Special core insulation
Black cores imprinted with U1, V2, W3
Green-yellow earth core depends on
conductor cross-section may cut into thirds
Cores stranded together with optimal
lay-length
Core wrapping between the layers of
stranding
Braided screening of tinned copper wires,
coverage approx. 85%
Full polyurethane outer sheat to
ULstd.1581 Tab.50227
Sheath colour orange (RAL 2003)
with meter marking


Flame retardant according to VDE


0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Halogen free to VDE 0482 part 267/ DIN EN
50267-2-1/ IEC 60754-1 (conforms to DIN
VDE 0472 part 815)
Oil resistant to IEC 60092-350, appendix F
Behaviour at low temperature at -40 C to
IEC 60092-350, appendixE
Weather, ozon and UV-resistant
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Application
HELUKABEL SHIPFLEX109 is a new developed and successfully tested special drag chain cable with overall screening which meets the
requirements of the strict standards for application in offshore-areas. For this two - line standard there is a Lloyds Register approval.
The outer sheath insulation of non-adhesive Polyurethan allows the application in extremely oily and rough environmental conditions.
For applications which go beyond standard solutions we recommend that you fill out our especially developed questionnaire for drag chains.
Before installation in cable drag chains please read the installation instructions.
EMC = Electromagnetic compatibility
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no.
19810
19811
19812
19813
19814
19815
19816

No.cores x
cross-sec.
mm
4G1
4G1,5
4G2,5
4G4
4G6
4G10
4G16

AWG-No. Outer
approx.
mm
18
9,0
16
10,5
14
11,7
12
13,4
10
15,6
8
19,2
6
23,9

Cop.
weight
kg/km
84,0
105,0
157,0
231,0
332,0
527,0
794,0

Weight
approx.
kg/km
124,0
175,0
265,0
390,0
570,0
804,0
1450,0


Part no.
19817
19818
19819
19820
19969
19821

No.cores x
cross-sec.
mm
4G25
4G35
4G50
4G70
3G95
4G95

AWG-No. Outer
approx.
mm
4
27,6
2
32,7
1
37,0
2/0
43,0
3/0
41,0
3/0
48,0

Cop.
weight
kg/km
1180,0
1600,0
2165,0
3196,0
3090,0
4606,0

Weight
approx.
kg/km
1660,0
2400,0
2600,0
4600,0
4480,0
5350,0

Dimensions and specifications may be changed without prior notice. (RN07)

W 21
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SHIPFLEX 113 cable for drag chain, halogen-free,


EMC prefered type, meter marking


Technical data

Cable structure

Properties

Special screened drag chain cable


UL-Style 20234
Temperature range
flexing -40 C to +80 C
fixed -40 C to +80 C
Installation temperature
minimum -25 C
Nominal voltage
to VDE U0/U 0,6/1 kV
UL 1000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius for permanent
bending
7,5x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, ultra-fine wire conductors


acc. to DINVDE0295 cl.6, BS 6360 cl. 6, IEC
60228 cl.6
Special core insulation
Black power supply cores with imprint U1,
V2, W3
Green-yellow earth core, dependsof the
diameter of the conductor
Black control cores with white numbers 5,6
Screening of the control cores in pairs
wrapped with plastic aluminium foil, and
tinned copper braided screening, approx.
coverage 85%
Control cores stranded in pairs and laid up
in layers together with the power supply
cores with optimal lay length and stabilising
filler
Core wrapping between the layers of
stranding
Braided screening of tinned copper wires,
coverage approx. 85 %
Full polyurethane outer sheat to
ULstd.1581 Tab.50227
Sheath colour orange (RAL 2003)
with meter marking


Flame retardant according to VDE


0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Halogen free to VDE 0482 part 267/ DIN EN
50267-2-1/ IEC 60754-1 (conforms to DIN
VDE 0472 part 815)
Oil resistant to IEC 60092-350, appendix F
Behaviour at low temperature at -40 C to
IEC 60092-350, appendix E
Weather, ozon and UV-resistant
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Application
HELUKABEL SHIPFLEX 113 is a new developed and successfully tested screened special drag chain cable which meets the requirements of
the strict standards for application in offshore-areas. This kind of cable combines the feeding cores with the control cores. For this two line standard there is a Lloyds Register approval .
The outer sheath insulation of non-adhesive Polyurethan allows the application in extremely oily and rough environmental conditions.
For applications which go beyond standard solutions we recommend that you fill out our especially developed questionnaire for drag chains.
Before installation in cable drag chains please read the installation instructions.
EMC = Electromagnetic compatibility
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.



Part no. No.cores x
cross-sec.
mm
19822
( 4G1,5 + (2 x 1,0))
19827
( 4G1,5 + (2 x 1,5))
19823
( 4G2,5 + (2 x 1,0))
19828
( 4G2,5 + (2 x 1,5))
19824
( 4G4 + (2 x 1,0))
19829
( 4G4 + (2 x 1,5))
19825
( 4G6 + (2 x 1,0))

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
11,5
138,0
254,0
12,0
148,0
265,0
13,0
176,0
328,0
14,0
187,0
339,0
14,5
258,0
460,0
15,0
268,0
475,0
17,0
348,0
596,0

AWG-No.
-


Part no. No.cores x
cross-sec.
mm
19830
( 4G6 + (2 x 1,5))
19826
( 4G10 + (2 x 1,0))
19831
( 4G10 + (2 x 1,5))
19832
( 4G16 + (2 x 1,5))
19833
( 4G25 + (2 x 1,5))
19834
( 4G35 + (2 x 1,5))
19835
( 4G50 + (2 x 1,5))

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
17,0
358,0
607,0
20,0
574,0
912,0
20,5
584,0
924,0
24,0
825,0
1205,0
28,5
1283,0
1510,0
32,0
1850,0
2005,0
37,0
2540,0
2890,0

AWG-No.
-

Dimensions and specifications may be changed without prior notice. (RN07)

W 22
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

SHIPFLEX 121 cable for drag chain, halogen-free,


EMC prefered type, meter marking


Technical data

Cable structure

Properties

Special screened drag chain cable


UL-Style 20234
Temperature range
flexing -40 C to +80 C
fixed -40 C to +80 C
Installation temperature
minimum -25 C
Nominal voltage
to VDE U0/U 0,6/1 kV
UL 1000 V
Insulation resistance
min. 200 MOhm x km
Minimum bending radius for permanent
bending
7,5x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, ultra-fine wire conductors


acc. to DINVDE0295 cl.6, BS 6360 cl. 6, IEC
60228 cl.6
Special core insulation
Black power supply cores with imprint U1,
V2, W3
Green-yellow earth core, depends of the
diameter of the conductor
Black control cores with white numbers 5,6
and 7,8
Screening of the control cores in pairs
wrapped with plastic aluminium foil, and
tinned copper braided screening, approx.
coverage 85%
Control cores stranded in pairs and laid up
in layers together with the power supply
cores with optimal lay length and stabilising
filler
Core wrapping between the layers of
stranding
Braided screening of tinned copper wires,
coverage approx. 85 %
Full polyurethane outer sheat to
ULstd.1581 Tab.50227
Sheath colour orange (RAL 2003)
with meter marking


Flame retardant according to VDE


0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Halogen free to VDE 0482 part 267/ DIN EN
50267-2-1/ IEC 60754-1 (conforms to DIN
VDE 0472 part 815)
Oil resistant to IEC 60092-350, appendix F
Behaviour at low temperature at -40 C to
IEC 60092-350, appendix E
Weather, ozon and UV-resistant
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Application
HELUKABEL SHIPFLEX121 is a new developed and successfully tested screened special drag chain cable which meets the requirements of
the strict standards for application in offshore-areas. This kind of cable combines the feeding cores with the control cores. For this two line standard there is a Lloyds Register Approval .
The outer sheath insulation of non-adhesive Polyurethan allows the application in extremely oily and rough environmental conditions.
For applications which go beyond standard solutions we recommend that you fill out our especially developed questionnaire for drag chains.
Before installation in cable drag chains please read the installation instructions.
EMC = Electromagnetic compatibility
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.


Part no. No.cores x


cross-sec.
mm
19836
( 4G1 + 2 x (2 x 0,75))
19837
( 4G1,5 + 2 x (2 x 0,75))
19838
( 4G2,5 + 2 x (2 x 1,0))
19839
( 4G4 + (2 x 1,5) + (2 x 1,0))
19840
( 4G6 + (2 x 1,5) + (2 x 1,0))

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
12,5
148,0
254,0
13,0
170,0
290,0
15,0
229,0
336,0
17,0
318,0
485,0
18,5
445,0
615,0

AWG-No.
-


Part no. No.cores x
cross-sec.
mm
19841
( 4G10 + (2 x 1,5) + (2 x 1,0))
19842
( 4G16 + 2 x (2 x 1,5))
19843
( 4G25 + 2 x (2 x 1,5))
19844
( 4G35 + 2 x (2 x 1,5))
19845
( 4G50 + 2 x (2 x 1,5))

Outer Cop.
Weight
approx. weight approx.
mm
kg/km kg/km
22,0
610,0
915,0
25,0
904,0
1226,0
29,0
1323,0
1595,0
33,0
1621,0
2196,0
37,0
2585,0
2995,0

AWG-No.
-

Dimensions and specifications may be changed without prior notice. (RN07)

W 23
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Technical Information

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Contents and Index


Subject

Page

X Technical Information
AWG-Wires and AWG-stranded conductors, Conductor make-up, cross-section, resistance and weight ........................................................ X 81 X 82
Cable lengths (m) to KTG-Drums capacity of pool drums .............................................................................................................................................X 110
Caloric load values of halogenated cables and insulated wires ....................................................................................................................................... X 76
Caloric load values of halogen-free and halogenated cables and insulated wires ......................................................................................................... X 77
Caloric load values of halogen-free Security Cables and insulated wires ................................................................................... X 73 X 75 + X 78 X 79
Caloric load values (heat of combustion) ......................................................................................................................................................................... X 72
Capacity of KTG-Pool drums............................................................................................................................................................................................X 109
Characteristics of insulating and sheath materials............................................................................................................................................... X 90 X 91
Chemical Resistance Table ..................................................................................................................................................................................... X 64 X 65
Chemical Resistance of Fluorinated polymeric materials ............................................................................................................................................... X 66
Chemical Resistance of PUR (Polyurethane)..................................................................................................................................................................... X 63
Chemical Resistance of Silicone ........................................................................................................................................................................................ X 68
Code-designation for harmonized cables and exible cords to DIN VDE 0292 and HD 361 S2/S3 ...................................................................... X 9 X 10
Code-designation-explanations for cables and insulated wire ........................................................................................................................................ X 14
Colour Abbreviations according to DIN VDE and IEC ....................................................................................................................................................... X 60
Colour code according to DIN 47100 with/ without colour repetition from core no. 45. and above........................................................................... X 49
Colour code according to DIN VDE 0293 .......................................................................................................................................................................... X 47
Colour code according to DIN VDE 0813 .......................................................................................................................................................................... X 57
Colour code according to DIN VDE 0815 .......................................................................................................................................................................... X 58
Colour code according to DIN VDE 0816 and extended .................................................................................................................................................. X 59
Colour code according to E DIN VDE 0245 part 1 ............................................................................................................................................................ X 48
Colour code according to international standard ................................................................................................................................................X 51 + X 52
Colour code for single wire vehicle cables ....................................................................................................................................................................... X 54
Colour code HELUKABEL-JB ............................................................................................................................................................................................. X 55
Colour code HELUKABEL-OB ............................................................................................................................................................................................ X 56
Comparison of harmonized cables with IEC, DIN VDE and HD ........................................................................................................................................ X 11
Conductor resistance (extracted from DIN VDE 0295, IEC 228 and HD 383) ................................................................................................................... X 16
Conductor-diameters according to DIN VDE 0295 ........................................................................................................................................................... X 15
Conversion factor for Medium Voltage Power Cables, 6 30 kV .................................................................................................................................... X 46
Copper and Alu-Price Calculation ............................................................................................................................................................................. X 3 X 4
Current carrying capacity and indications for calculation of Power Cables and Wires ................................................................................................... X 19
Current carrying capacity for NYKY 0,6/1 kV .................................................................................................................................................................... X 33
Current ratings Conversion factors for deviating ambient temperature ...................................................................................................................... X 35
Current ratings Conversion factors for grouping of multicore cables or cables on troughs and trays ....................................................................... X 37
Current ratings Conversion factors for grouping of single core cables or cables on troughs and trays ..................................................................... X 36
Current ratings Conversion factors for grouping on the wall, on the oor, in insulation tubes or in conduit and under the ceiling ....................... X 34
Current ratings (general) for exible cables, for non-existing cable types in the previous tables ................................................................................ X 28
Current ratings for cables 0,6/1 kV, Special rubber-insulated single core cables, multicore rubber cables and trailing cables ................................ X 27
Current ratings for cables and insulated wires up to 1000 V and heat resistant cables ................................................................................................ X 26
Current ratings for HELUTHERM 145 ...............................................................................................................................................................................X 29
Current ratings for installation A1, A2, B1 and B2, Cables for xed installation within buildings .................................................................................. X 22
Current ratings for installation conditions A1, A2, B1 and B2, Cables for xed installation within buildings................................................................ X 24
Current ratings for installation conditions C, E, F and G, Cables for xed installation within buildings ........................................................................ X 23
Current ratings for installation conditions C, E, F and G, Cables for xed installation within buildings ........................................................................ X 25
Current ratings for NYY, NAYY, NYCY, NYCWY, NAYCWY 0,6/1 kV and N2XY, NA2XY, N2XCY, NA2XCY 0,6/1 kV .................................................. X 31 X 32
Current ratings for silicone cables and wires ................................................................................................................................................................... X 30
Current ratings for UL-CSA cables ..................................................................................................................................................................................... X 84
Denitions: Classes of Stress (Duty) in Flexible Cables and Insulated Wires .................................................................................................................... X 92
Designation code for harmonized cables according to DIN VDE 0281/DIN VDE0282/DIN VDE 0292 .............................................................................. X 8
Designation code for power cables according to DIN VDE0271/0276 ............................................................................................................................ X 12
Designation code for telephone cables, jumper wires and stranded hook-up wires .................................................................................................... X 13
Electrical characteristics of XLPE-insulated Medium Voltage Power Cables, 6 30 kV ...................................................................................... X 39 X 43
European Directives WEEE, RoHS and ElektroG ..............................................................................................................................................................X 113
Explanatory notes on CE marking.....................................................................................................................................................................X 111 X 112
Fluorinated polymeric materials: PTFE, FEP, PFA, ETFE ............................................................................................................................................................X 67
Formulas of electrotechnic and electronic, Formulas of power engineering ................................................................................................X 107 X 108
Glossary of Terms: Cables and Wires ...................................................................................................................................................................X 98 X 105
Halogen-free Security Cables and Wires ............................................................................................................................................................... X 69 X 71
Harmonized Identication................................................................................................................................................................................................... X 7
Heat-resistance classes as per VDE 0530 part1 ................................................................................................................................................................ X 72
Identication of insulated wires by colours according to DIN 40705 and CEI/IEC 60446 ............................................................................................... X 61
Index British Standard .......................................................................................................................................................................................... X 87 X 88
Information and Installation Instructions for UL and CSA cables ..................................................................................................................................... X 80
Installation Methods and Operating Conditions Power cables and insulated wires for xed installation .................................................................... X 20
International abbreviations ............................................................................................................................................................................................... X 89
International Certication Marks and Testing Institute ..................................................................................................................................................X 106
Laying Conditions for Power Cables ................................................................................................................................................................................. X 21
List of UL-Styles (Multicore cables) .................................................................................................................................................................................... X 86
List of UL-Styles (Single core cables) ................................................................................................................................................................................. X 85
Nominal voltage and Operating voltage ........................................................................................................................................................................... X 18
Pair-Colour code according to DIN 47100 with colour repetition from pair no. 45 and above ..................................................................................... X 50
Pair-Colour code according to international standard.........................................................................................................................................X 51 + X 53
Permissible minimum bending radius according to DIN VDE specications .................................................................................................................. X 62
Power ratings for XLPE-insulated Medium Voltage Power Cables 6/10 kV, 12/20 kV, 18/30 kV .................................................................................... X 38
Rating conversion factors for installation of Medium Voltage Cables, 6 30 kV ............................................................................................... X 44 X 45
Reference to DIN VDE Standards .............................................................................................................................................................................. X 5 X 6
Resistance of substances against solvents, oils and fats ................................................................................................................................................. X 68
Safety Requirements in the Use of Cables and Insulated Wires .......................................................................................................................... X 93 X 97
Strand make-up according to DIN VDE 0295, IEC 60228 and HD 383................................................................................................................................................ X 17
US-American and British units, Conversion of usual measuring units ............................................................................................................................ X 83

X2
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Copper and Alu-Price Calculation


The material price for cables and wires is usually based on a copper price of 150,00 EUR/100 kg.
For invoicing, as copper surcharge the difference to the daily copper rate will be calculated.

The Formula for calculating the copper surcharge:


Copper surcharge in EUR/km = Copper value (kg/km) x

(DEL+1% delivery charge) copper basis


100

DEL
The DEL (German electrolytic copper for guiding purpose) is the Stock Exchange Quotation for 99,5% pure
copper. The value is given per EUR/100 kg in the economic part of daily newspapers.
Example:

DEL quotation = 194,29 i. e.,


100 kg copper cost 194,29 EUR and
1% delivery charge is added to the daily quotation for cables and wires.

Copper basis
In our catalogue, for almost all cables and wires, a certain portion of copper price is already included.
Standard cables

copper basis = EUR 150,0/100 kg

Telephone cables

copper basis = EUR 100,0/100 kg

Power cables

copper basis = EUR

0, /100 kg (copper base = 0)

Copper value
The copper value is stated in our catalogue. It is the copper weight of a cable or a wire.
Example:

JZ-500 8 x 0,75 mm2, Part-No. 10040


Copper value 58 kg/km

Calculation example: for


JZ-500

8 x 0,75 mm2

DEL

194,29 EUR/100 kg (assuming value)

Copper basis

150,0 EUR/100 kg

Copper value

58 kg/km

Copper surcharge =

(194,29 + 1,9429) 150,0


x 58 kg/km
100

(calculated value 1,9429 = 1% of 194,29)

= 26,82 EUR/km

The net price including copper is calculated as follows:


Gross price
. /. individual discount
+ Copper surcharge

Note: The copper surcharge is indicated separately in our invoices.

Continuation 

X3
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Copper and Alu-Price Calculation


Calculation examples:
Assumption:

DEL-Quotation 194,29 EUR/100 kg for copper


Daily rate
173,84 EUR/100 kg for aluminium
Individual discount, e. g. 20%

1. NYY-J 3 x 70/35 sm,

0,6/1 kV, Part no. 32038

Quantity ordered 1000 m


Copper base = 0
minus 20% (discount)

9300,00 EUR/km
1860,00 EUR/km
7440,00 EUR/km

+ Copper surcharge:
(194,29 + 1,9429) 0
x Copper value
100
equal, 1,962 EUR/kg x 2352 kg/km =

2. NYCWY 3 x 70/35 sm,

4614,62 EUR/km
12054,62 EUR/km

0,6/1 kV, Part No. 32268

Quantity ordered 1000 m


Copper base = 0
minus 20% (discount)

14780,00 EUR/km
2956,00 EUR/km
11824,00 EUR/km

+ Copper surcharge (Conductor + screen):


(194,29 + 1,9429) 0
x Copper value
100
equal, 1,962 EUR/kg x 2410 kg/km =

3. NA2XSY 1 x 70 sm/16,

4728,42 EUR/km
16552,42 EUR/km

12/20 kV, Part No. 32454

Quantity ordered 1000 m


Aluminium conductor
Copper screen
Copper base = 0
minus 20% (discount)

9500,00 EUR/km
1900,00 EUR/km
7600,00 EUR/km

+ Copper surcharge (screen):


(194,29 + 1,9429) 0
x Copper value
100
equal, 1,962 EUR/kg x 182 kg/km =
+ Aluminium (Conductor):
Aluminium value x daily rate
203 kg/km x 1,74 EUR/kg

357,08 EUR/km

353,22 EUR/km
8310,30 EUR/km

X4
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Reference to DIN VDE Standards


Power Installations

DIN VDE 0100


DIN VDE 0100 part 100
DIN VDE 0100 part 410
DIN VDE 0100 part 430
DIN VDE 0100 part 482
DIN VDE 0100 part 520/part 530

Erection of power installations with rated voltages below 1000


General requirements, scope
Protective measures and protection against electric shock
Protection of cables against overcurrent
Choice of protective measures, protection against re
Selection and erection of equipment cable, wires and wiring systems
Erection electrical equipment switch- and controlgear
DIN VDE 0100 part 559
Luminiaries and lighting equipment
DIN VDE 0100 part 701
Rooms containing a bath tub or shower basin
to part 705
Roofed swimming pools (swimming baths) and open
air swimming baths
Rooms containing electrical sauna-heaters Installations site
Agricultural and horticultural premises
DIN VDE 0100 part 720
Fire-hazards locations
DIN VDE 0100 part 726
Lifting and hoisting devices
up to 0 part 737
Laying of cables in hollow walls and in buildings made up mainly
ammable building materials
Cable entries into buildings in public cable network
Humid and wet areas, outdoor installation
DIN VDE 0101
Erection of power installations with rated voltages above 1 kV
DIN VDE 0105
Operation of power installations
DIN VDE 0107
Electrical installations in hospitals and locations for medical
use outside hospitals
DIN VDE 0108 part 1
Power installations and safety power supply
up to part 100
in comunal facilities, stores and shops and exhibition rooms,
multi-storey buildings, Restaurants, closed car parks and working
or business premises
DIN VDE 0113
Electrical equipment of industrial machines
DIN VDE 0118
Erection of electrical installations in mines
DIN VDE 0165
Installation of electrical apparatus in hazardous areas
DIN VDE 0166
Electrical installations and apparatus thereof for use in atmospheres
potentially endangered by explosive material
DIN VDE 0168
Erection of electrical installation in open cast mines quarries
and similar plants
DIN VDE 0170/0171
Electrical apparaturs for potentially explosive atmospheres
DIN VDE 0185
Lightning protection system, protection of structures against lightning
DIN VDE 0207 part 1 up to part 24 Insulating and sheathing compounds for cables and exible cords
DIN VDE 0245 part 1
Cables and cords for electrical and electronic equipment
in power installations
DIN VDE 0245 part 101
Flexible PVC-insulated control cable
up to part 202
DIN VDE 0250 part 1
Cables, wires and exible cords for power installation
up to part 819
DIN VDE 0253
Heating cables

Power guides
DIN VDE 0262
DIN VDE 0265
DIN VDE 0266 part 3 and part 4

XLPE (cross linked PE) insulated and PVC sheathed installationscable


up to 0,6/1 kV
Cables with plastic-insulated lead-sheat for power installation
Halogen-free cables with improved characteristics in the case of re,
with reduced re propagation and continuance of isolation for use
in the containment of nuclear power plants

X
X5
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Reference to DIN VDE Standards


Power guides
DIN VDE 0271
DIN VDE 0276 part 603
DIN VDE 0276 part 604

DIN VDE 0276 part 604/605


DIN VDE 0276 part 620
DIN VDE 0276 part 1000
DIN VDE 0276 part 1001

DIN VDE 0277


DIN VDE 0281 part 1 to part 404
DIN VDE 0282 part 1 to part 808

DIN VDE 0284


DIN VDE 0289 part 1 to part 101
DIN VDE 0292
DIN VDE 0293
DIN VDE 0295
DIN VDE 0298 part 1 to part 300

PVC-insulated cables and sheathed power cables for rated voltages


up to and including 3,6/6 (7,2) kV
Distribution cables of nominal voltages U0 /U 0,6/1 kV
Power cables of nominal voltages U0 /U 0,6/1 kV with special re
performance for use in power stations
Additional test methods
Distribution cables of nominal voltages U0 /U 3,6 kV to 20,8/36 kV
Current-carrying capacity, general; conversion factors
Tests on cables laid with nominal voltages U0 /U 6/10 kV,
12/20 kV and 18/30 kV with PVC-insulation, VPE-insulation
or paper insulation.
Primary cables for airport lighting
PVC-cables, wires and exible cords for power installation
Rubber cables and exible cords for power installation, heat-resistant
silicon rubber insulated cable, halogen-free insulated cable arc
welding cable, rubber insulated lift cable, rubber-sheathed
exible cables
Mineral insulated cables with a rated voltages not exeeding 750 V
Denations for cables, wires and exible cords for power installation
Code designation for harmonized cables and exible cords for power
installations
Core identication for cables and exible cords used in power
installation
Conductors of cables, wires and exible cords for power installation
Application of cables and exible cords in power installations

Testing, measurement
DIN VDE 0472 part 1 to part 818 Testing of cables, wires and exible cords
DIN VDE 0473 up to part 811
Insulating and sheating materials of electric cables;
Common test methods
DIN VDE 0482 up to part 268
Measurement of smoke density of cables
Telecommunications, Switchboard and Installations-cable
DIN VDE 0800 part 1 to part 10
Telecommunications
DIN VDE 0811
Ribbon cables with round conductors, with a pitch of 1,27 mm
DIN VDE 0812
Equipment wires and stranded equipment wires of
telecommunications system
DIN VDE 0813
Switchboard cables for telecommunications system
DIN VDE 0814
Cords for telecommunications system
DIN VDE 0815
Wiring cables for telecommunications system (indoor cable)
DIN VDE 0816 part 1 to part 3
Outdoor cables for telecommunications system
DIN VDE 0817
Cables with stranded conductors for increased mechanical stress
for telecommunications system
DIN VDE 0818
Self-supporting telecommunication aerial cables on overhead
power lines above 1 kV
DIN VDE 0839
Electromagnetic compatibility
DIN VDE 0881

Equipment wires and exible equipment wires with extended


temperature
DIN VDE 0891 part 1 to part 10
Special directions and guidings principles of cables and insulated wires
DIN VDE 0899 part 1 up to part 5 Special specication for optical ber, single cores, indoor and
outdoor cables

X6
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Harmonized Identication
The harmonized identications for cables and wires come to an agreement with the CENELEC-structure
(HAR-agreement) are determined by the certication institute. These identications conform the
harmonized standards.
The harmonized identication must be visible on the core or the sheath in form of an imprint or embossing, or contained with a three-coloured black-red-yellow protected identication thread of different
colour lengths (dimension in cm).

Harmonized identication
Kind of imprint
or
embossing

Colour of identication thread


black red yellow
(dimension in cm)

Country

Certication institute
Name

Designation

CEBEC HAR

Belgium

Comite Electrotechnique Belge

CEBEC

VDE HAR

Germany

Verband Deutscher Elektrotechniker e.V.


VDE Prf- und Zertizierungsinstitut

VDE

USE HAR

France

Union Technique de lElectricit

UTE

IEMMEQU HAR

Italy

Instituto Italiano de Marchio Qualit

IMQ

BASEC HAR

Great Britain
and North Ireland

British Approvals Service for Cables

BASEC

KEMA-KEUR HAR

Netherlands

N.V. tot Keuring van Elektrotechnische


Materialien

KEMA

SEMKO HAR

Sweden

Svenska Elektriska
Materielkontrollanstalten

SEMKO

VE HAR

Austria

sterreichischer Verband
fr Elektrotechnik

VE

DEMKO HAR

Denmark

Danmarks Elektriske Materialkontroll

DEMKO

NSAI HAR
IIRS HAR

Ireland

National Standards Authority of


Ireland old: Institute for Industrial
Research and Standards

NSAI
(IIRS)

NEMKO HAR

Norway

Norges Elektriske Materiellkontroll

NEMKO

<>UNE<> HAR
((<>UNE<>))

Spain

up to 31. 12. 1992: Asociacin Electrotcnica


y Electrnica Espaola

AEE

AENOR HAR

from 01.01.1993: Asociacin Espaola de


Normalizacin y Certicacin

AENOR

ELOT HAR

Greece

Hellenic Organization for Standardization

ELOT

IPQ HAR

Portugal

Instituto Portugus da Qualidade

IPQ

SEV HAR

Switzerland

Schweizerischer Elektrotechnischer Verein

SEV

FIMKO

Finnland

FIMKO LTD

FIMKO

MEEI HAR

Hungarian

Magyar Elektrotechnikai Ellenrz Intzet

MEEI

X
X7

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Designation code for harmonized cables


according to DIN VDE 0281/DIN VDE 0282/DIN VDE 0292
Construction reference

H 05 V

V5

25 G 0,75

Identications of destignation
A
authorised national standards
H
harmonized standards
Nominal voltage U
01
100 V
03
300/300 V
05
300/500 V
07
450/750 V
Insulation material
B
(EPR) Ethylene-propylene-rubber
G
(EVA) Ethylene-Vinylacetat-Copolymer
N2
(CR) Chloroprene rubber for welding cables
R
(NR a./o. SR) Natural a./o. synthetic rubber
S
(SiR) Silicone rubber
V
(PVC) Polyvinyl chloride
V2
(PVC) Polyvinyl chloride heat-resistant
V3
(PVC) Polyvinyl chloride low-temperature
V4
(PVC) Polyvinyl chloride cross-linked
Z
(PE) Polyethylene cross-linked
Structural elements
C4
Cooper-Screen braiding over laid-up cores
Q4
(PA) Additional polyimide core jacket
T
Additional textile braiding over laid-up cores
T6
Additional textile braiding over individual cores
Sheath/jacket material
B
(EPR) Ethylene-propylene rubber
J
Glass bre braid
N
(CR) Chloroprene rubber
N2
(CR) Chloroprene rubber for welding cables
N4
(CR) Chloroprene rubber heat-resistant
Q
(PUR) Polyurethane
R
(NR a./o. SR) Natural- a./o. synthetic rubber
T
Textile braid
T2
Textile braid with ame retardant compound
V
(PVC) Polyvinyl chloride
V2
(PVC) Polyvinyl chloride heat-resistant
V3
(PVC) Polyvinyl chloride low-temperature
V4
(PVC) Polyvinyl chloride cross-linked
V5
(PVC) Polyvinyl chloride oil resistant
Special structural features
D3
Stress-relieving elements (support wire)
D5
Centre core (no supporting element)
FM
Telecommunications cores integrated in power cables
H
Flat, separable cable (twin cable)
H2
Flat, non-separable cable (two-core sheathed cable)
H6
Flat, non-separable cable (multi- and multiple sheathed cable)
H7
Two-layer insulating jacket
H8
Spiral cables
Conductor type
D
Finely stranded, for welding cables
E
(very) nely stranded, for welding cables
F
Finely stranded, for cables for exible installation
H
(Very) nely stranded, for exible cables
K
Finely stranded, for cables for xed installation
R
Multiple-wire, round, class 2
Single-wire, round, class 1
U
Y
Tinsel wire, DIN 47104
Number of cores
Earth core
G
X

With earth core


Without earth core

Conductor nominal cross section in mm2


Examples:
H07V-U 2,5 black (according to DIN VDE 0281)
Harmonized PVC-insulated single-core sheathed cable, 2,5 mm2
single-core, nominal voltage 750 V

H07RN-F 3G 1,5 (according to DIN VDE 0282)


Harmonized rubber-sheathed-cable for medium tensile loads,
three-core 1,5 mm2, nely stranded, green-yellow earth core, nominal voltage 750 V

X8
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Code-designation for harmonized cables and


exible cords to DIN VDE 0292 and HD 361 S2/S3
This system of code-designation is prepared by CENELEC for harmonized cables as exible cords for power installations and published
in Harmonization Document 361 S3.

Kind of Standards

Insulation and sheath materials

CodeClassied to
designation Standards

Codedesignation Materials

H
A

cables and wires to harmonized documents


authorised national standards
Conductor material

without
designation Copper
A
Aluminium
Z
Conductor of special material and/or
special shape

G
J
J2
M
N
N2
N4
N5
N6
N7
N8

Type and shape of conductor


P

D
E
F
H
K

M
R
S
U
W
Y
Z

ne wire stranded conductor for welding cables


extra ne wire stranded conductor for welding cables
ne wire stranded conductor for exible
cables according to DIN VDE 0295, class 5
extra ne wire stranded conductor for exible
cables according to DIN VDE 0295, class 6
ne wire stranded conductor for xed
installation (if not specied, equivalent to
DIN VDE 0295, classe 5)
Milliken conductor
conductor of multistranded wires
sector-shaped conductor of multistranded wires
round conductor of single wire
sector-shaped conductor of single wire
tinsel conductor
conductor of special material and/or special
shape
Core numbers and cross-section of
conductor

Number
X
G
Y

number of cores n
Multiplication sign without green-yellow core
Multiplication sign for green-yellow core
tinsel conductor, whereby the cross-section is
not specied
Insulation and sheath materials

B
B2
B3
E
E2
E4
E5
E6
E7

Ethylene-propylene-rubber for Temp. of +90C


Ethylene-propylene rubber, hardend
Butyl rubber (isobutylene-isoprene rubber)
Polyethelene
Polyethelene, high density
Polytetrauorethylene
Peruor (Ethylene-propylene copolymers)
Ethylene-tetrauorethylene copolymers
Polypropylene

Q
Q2
Q3
Q4
Q5
Q6
R

S
T
T2
T3
T4
T5
T6

V
V2
V3
V4
V5
X
Z

Z1

Ethylene-vinylacetate copolymers
braiding of glass bre
wrapping of glass bre
mineral insulation
chloroprene-rubber (or equivalent material)
special compound of chloroprene-rubber
Sulfonated chlor or chlorinated polyethelene
Nitril-rubber
Florinated rubber
PVC-Nitril-rubber compound
Special-polychloroprene-rubber,
water resistant
Cables with impregnated paper insulation for
multicore belted cable
Polyurethane
Polyethyleneterephthalate
Polystyrole
Polyamide
Polyimide
Polyvinylidene uoride
Ethylene-propylene rubber or equivalent
synthetic elastomer for +60C temperature of
+60C, for permanent temperature of +60C
Silicon-rubber
textile braiding over twisted cores,
impregnated/unimpregnated
textile braiding with amme retardant
impregnated composition
layer of textile as core wrapping or tape
layer of textile as core wrapping or tape with
ame retardant impregnated composition
corrosion protection
textile braiding over individual core or
multicore
cable, impregnated/unimpregnated
PVC soft
PVC soft, resistant to increased temperature,
+90C
PVC soft, for low temperatures
PVC soft, cross-linked
PVC soft, oil resistant
cross-linked polyethylene
cross-linked compound to a basis of
polyolene,
for low corrosiv gas and low smoke emission in
case of re
Thermoplastic compound to a basis of
polyole-ne, for low corrosiv gas and low
smoke emission in case of re
Continuation 

X9
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Code-designation for harmonized cables and


exible cords to DIN VDE 0292 and HD 361 S2/S3
Metal sheath, concentric conductor and screens

Armouring

Codedesignation

Codedesignation

A2
A3
A4
A5
C2
C3
F
F3
K
L
L2
L4
L5
L6

Metal sheath

Aluminium sheath, pressed or welded, smooth


Aluminium sheath, pressed or welded,
corrugated
Aluminium sheath over individual core
Aluminium sheath of Band
Copper sheath
Copper sheath, corrugated
Steel sheath
Steel sheath, corrugated
Zinc sheath
Alloyed lead sheath for general use
non-alloyed lead sheath, normal pure lead
alloyed lead sheath over individual core
non-alloyed lead sheath over individual core
alloyed lead sheath, but other composition
than above

Z2
Z3
Z4
Z5
Z6
Z7
Y2
Y3
Y5
Y6

Armouring**

Armouring of round steel wires*, galvanized/


ungalvanized
Armouring of at steel wires*, galvanized/
ungalvanized
Armouring of steel tape, galvanized/
ungalvanized
Braiding of steel wires, galvanized,
ungalvanized
Supporting braid of steel wires
Armouring of sectional steel wires
Armouring of round aluminium wires*
Armouring of at aluminium wires*
Armouring of special materials
Armouring of steel wires and/or steel tape and
copper wires
* counter helix, if specied
** see remarks DIN VDE 0292

Concentric conductors
Special constructive supporting elements
A
A6
C
C6
C9

concentric aluminium conductor


concentric aluminium conductor,
meander-shaped
concentric copper-conductor
concentric copper-conductor,
meander-shaped
divided concentric copper conductor

D2
D3

D4

Screens
D5
A7
A8
C4
C5
C7
C8
D

Aluminium screen
Aluminium screen of individual core
Copper screen as braid over the
stranded cores
Copper screen braiding over individual core
Copper screen of tape, round or prole-wires
over twisted cores
Copper screen as C7, over individual core
screen of one or more thin steel tapes, laying
direkt over twisted cores, in contact with a
stranded plain conductor

D7
D8

Supporting elements of textile or steel wires


over cable core
Textil supporting elements of one or more
elements, stranded in the core of circular cable
or placed in a at cable
self-supporting cables and wires, where the
conductor permits the strain-relieving
function
central core element (not as supporting
element), used for lift cable
as D3, the supporting element however is
connected externally
as D7, however a section horizontal to the axis
of the cable forming the number 8

Special versions
without
designation round cable construction
H
at type as seperable cables with or without
sheath
H2
at type of cables unseperable
H3
building cable, at webbed
H4
multicore at cable with one plain conductor
H5
two or more single core stranded,
non-sheathed cables
H6
at cables according to HD 359 or EN 50214
with 3 or more cores
H7
Cable with two-sheathed extruded insulation
H8
Coiled conductor

X 10
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Comparison of harmonized cables


with IEC, DIN VDE and HD
PVC-insulated cables according to DIN VDE 0281 in comparison with IEC and HD
Designation

accord.
to VDE
part . . .

short
short desig- nominal
nominal
designation nation old
cross-sec- voltage
new
VDE 0250
tion (mm2) U0/U (V)

according comparative
to HD
design
to IEC

PVC-wiring cables
single wire
ne wires

0281 part 3
0281 part 3

H 05V-U
H 05V-K

NYFA, NYA
NYFAF, NYAF

0,5 to 1,0

300/500

HD 21.3 S3

227 IEC 01
227 IEC 01

PVC-insulated cables
single wire
multi-stranded wires
ne wires

0281 part 3
0281 part 3
0281 part 3

H 07V-U
H 07V-R
H 07V-K

NYA
NYA
NYAF

1,5 to 10
1,5 to 400
1,5 to 240

450/750

HD 21.3 S3

227 IEC 01
227 IEC 01
227 IEC 02

Light PVC-Twin cables

0281 part 5

H 03VH-Y

NLYZ

0,1

300/300

HD 21.5 S3

227 IEC 41

Twin cables

0281 part 5

H 03VH-H

NYZ

0,5+0,75

300/300

HD 21.5 S3

227 IEC 42

PVC-sheathed cables 03VV-F


round
at

0281 part 5
0281 part 5

H 03VV-F
H 03VVH2-F

NYLHY rund
NYLHY ach

0,5+0,75
0,5+0,75

300/300

HD 21.5 S3

227 IEC 43
227 IEC 43

PVC-sheathed cables 05 VV-F


round

0281 part 5

H 05VV-F

NYMHY rund
NYMHY rund
NYMHY ach

0,75 to 2,5
1 to 2,5
0,75

300/500

NYFLY
NYFLY

0,75 to 1
1,5 to 25

300/500
450/750

at

0281 part 5

H 05VVH2-F

PVC-Flat-cable 05VV-H6
PVC-Flat-cable 07VV-H6

0281 part 403 H 05VVH6-F


0281 part 404 H 07VVH6-F

227 IEC 53
HD 21.5 S3

300/500

227 IEC 53

Rubber insulated power cables according to DIN VDE 0282 in comparison with IEC and HD
Designation

according
to VDE

short
short desig- nominal
nominal
designation nation old
cross-sec- voltage
new
VDE 0250
tion (mm2) U0/U (V)

according comparative
to HD
design
to IEC

Heat-resistant rubberinsulated
cable H 07G

0282 part 7
0282 part 7

H 07G-U
H 07G-K

N4GA
N4GAF

1,5+2,5
0,5 to 95

450/750

HD 22.7 S2

Heat-resistant siliconerubber
cable

0282 part 3

H 05SJ-K

N2GAFU

0,5 to 95

300/500

HD 22.3 S2

245 IEC 03

Braided exible cord

0282 part 4

H 03RT-F

NSA

0,75 to 1,5

300/500

HD 22.4 S3

245 IEC 51

Rubber sheathed exible


cord 05RR

0282 part 4

H 05RR-F

NLH, NMH

0,75 to 2,5

300/500

HD 22.4 S3

245 IEC 53

Polychloroprene sheathed
exible cable 05RN

0282 part 4

H 05RN-F

NYMHu
NYMHu
NYMHu

0,75+1
0,75+1
0,75

300/500

HD 22.4 S3

245 IEC 57
245 IEC 57
245 IEC 57

Polychloroprene sheathed
exible cable 07RN

0282 part 4

H 07RN-F

NMHu
NSHu

1,5 to 500
1 to 25
1 to 300
1,5+2,5

450/750

HD 22.4 S3

245 IEC 65
245 IEC 66

Rubber insulated lift cable


with textile braid
05RT2D5
Rubber insulated lift cable
with polychloroprene
sheath 05RND5

0282 part 807 H 05RT2D5-F

NFLG

0,75

300/500

0282 part 807 H 05RND5-F

NFLGC

0,75

300/500

Rubber insulated lift cable


with textile braid
07RT2D5
Rubber insulated lift cable
with polychloroprene
sheath 07RND5

0282 part 808 H 07RT2D5-F

NFLG

450/750

0282 part 808 H 07RND5-F

NFLGC

450/750

IEC-denation
IEC 227: Polyvinylchloride insulated exible cables and cords with circular conductors and a rated voltage not exceeding 750 V
IEC 245: Rubber insulated exible cables and cords with circular conductors and a rated voltage not exceeding 750 V

X
X 11

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Designation code for power cables


according to DIN VDE 0271/0276
Construction reference

Identications of designation
N
DIN VDE standard
(N)
similar to DIN VDE standard
Conductor material
A
aluminium conductor

copper conductor
Insulating materials
Y
PVC
2X
cross-linked PE (XLPE)

impregnated paper
Concentric conductor (screen)
C
concentric conductor of copper
CW
concentric conductor of copper in waveconal formation
CE
concentric conductor of copper over each individual core
S
screen of copper wires
SE
screen of copper wires over each individual core
H
conductive layers
(F)
longitudinally water-proof screen
Armouring
B
F
G
R

steel tape armouring


armour of galvanized at steel wires
counter helix of galvanized steel tape
armour of galvanized round steel wires

Sheath Material
A
oversheath made of brous material
K
ead sheath
KL
aluminium sheath

Y
2Y

PVC
PE

..m
..h
/V

stranded conductor
hollow circular conductor
compact conductor

Protective Conductor
I
with protective conductor
O
without protective conductor
Number of cores
Conductor cross section in mm2
Conductor type
r ...
circular conductor
s ...
sector conductor
o ...
oval conductor
e ...
circular, solid conductor
Rating Voltage
0,6/1 kV
3,6/6 kV
6,0/10 kV
12/20 kV
18/30 kV

Examples
NA2XS2Y 1x 35 RM/16 6/10 kV
Single core XLPE-insulated cable with PE-sheath according to standard, circular, stranded aluminium conductor with nominal
cross-section 35 mm2, covered with copper-screen 16 mm2 and rating voltage (U0 /U) 6/10 kV
NYY-J 12x 1,5 RE 0,6/1 kV
Cable according to standard, PVC-insulated, sheath PVC, with green-yellow marked core, 12 cores with nominal cross-section
1,5 mm2, circular conductor, solid, rating voltage 0,6/1 kV

X 12
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Designation code for telephone cables,


jumper wires and stranded hook-up wires
Construction reference

Basic cable type with additional information


A
outdoor cable
IE
AB
outdoor cable with lightning
protection requirements
IE-H
AJ
outdoor cable with induction
protection requirements
G
mining cable
S
I
installation cable
T
YV/Li...
Insulation
P
dry paper
Y
PVC (Polyvinylchloride)
2Y
PE (Polyethylene)
02Y
foamed PE (cellular)
02YS
foam-skin insulation

3Y
5Y
6Y
7Y

Screening
C
screen of braided copper wires (ms)
D
copper screen, helically stranded (St)
F
lling of cable core with petrol-jelly (Z)
(K)
screen of copper tape with
PE-inner sheath
(L)
aluminium tape

installation cable for


industrial electronic
installation cable for
industrial electronic,
halogen-free
switchboard cable
distribution cable
jumper wires/hook-up wires

Styroex
PTFE
FEP
ETFE

magnetic screen steel tape


screen of plastic coated metallic foil
high tensile steel wire braiding

Sheath Material
L
smooth aluminium sheath
M
(L)2Y
copolymer coated aluminium Mz
moisture barrier sheath
W
LD
corrugated aluminium sheath

lead sheath
lead alloy sheath
corrugated steel sheath

Protective coating
Y
PVC sheath
Yv
reinforced protective sheath
of PVC
Yw
PVC sheath heat-resistant
Yu
PVC ame resistant (non-ammable)

2Y
2Yv
E
C

PE sheath
reinforced protective PE sheath
compound with embeded plastic tape
protective covering of jute and compound

Number of stranding elements


.. x1x
single core
.. x2x
pair (double cores)
.. x3x
triple

.. x4x
.. x5x

quad
ve-core

Conductor diameter in mm
Type of stranding components
F
star quad with phantom
circuit in railway cables
S
signal core in railway signal cable
StO
star quad general
St
star quad with phantom
circuit for long distance
St I
star quad without phantom circuit
St II
star quad like St III, but with
increased capacitance unbalances
St III
star quad in local (Subscriber) cable
St IV
star quad for transmission of
f = 120 kHz

St V
St VI
DM
TF
P
PiMF
ViMF
BdiMF
Kx

star quad for transmission of f = 550 kHz


star quad for transmission of f = 17 MHz
Dieselhorst-Martin quad
carrier frequency star quad
twisted pair
pair in metal foil
quad in metal foil
unit in metal foil
coaxial cable

Stranding layout
Lg
ayer stranding concentric
Bd
unit stranding
Armouring wire
A
layer of Al-wires for
inductive protection
b
armouring
B
armouring of steel band for
inductive protection
1B 0,3
1 layer steel tape,
thickness 0,3 mm

2B 0,5
D
(T)

2 layers steel tape, thickness 0,5 mm


layer of copper wires for inductive protection
strain bearing of steel wires for
aerial cable

X
X 13

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Code-designation-explanations for cables and


insulated wire
AA
AB
AD
AJASLH
B
B
b
(1B...)
(2B...)
BD
BLK
BZ
C
C
C
Cu
(-Cu)
D
(D)
DM
Dreier
E
E(e)
e
F
F
F
F
F
(F...)
OF
FR
f
ff
G
GGJ
GS
2G
3G
4G
5G
6G
7G
8G
9G
53G
H
H
(H...)
(HS)
HX
...IMF
IMF
-J
-JZ
K
(K)
LA
LD
Lg
Li
(L)Y
(L)2Y
2L
M
M
Mz
(mS)
N
(N)
NC
NF
-O

Outdoor cable
approved national design
Outdoor cable with lighting protection
Outdoor cable with differential protection
Outdoor cable with induction protection
self-supporting communication cables for high voltage
overhead lines
armouring
spinning of textile yarn
armouring
one layer of steel tape... thickness of the steel tape in mm
two layers of steel tape... thickness of the steel tape in mm
unit-type stranding
bare copper-conductor without insulation
bronze conductor
screen of copper wire braiding
screen of copper wire spinning
outer protection of jute and viscous compound
copper wire
total cross-section of copper screens (mm2)
screen of copper wires
screen of helically applied copper wires
Dieselhorst-Martin quad
three cores in triple stranded
copper drain wire
protective covering of viscous compound with
embedded layer of plastic tape
single wire, solid
cable cores assembly with petrol-jelly
foil wrapping
at cable
star quad for railway cable
star quad for phantom circuits
at wire armouring... thickness in mm
jelly lled cable core, lling compound of hard substances
ame retardant
exible, ne wire stranding
extra ne wire stranding
insulation or sheath material of rubber (NR) or (SBR)
Mining cable
Mining cable with induction protection
glass bre whipping or braiding
insulation or jacket of silicone rubber, (SIR)
insulation or jacket of ethylene propylene rubber, (EPR)
insulation or jacket of ethylene vinylacetate rubber (EVA)
insulation or jacket of chloroprene rubber (CR)
insulation or jacket of chlorosulphonated polyethylene
(CSM), Hypalon
insulation or jacket of Flouroelastomer (FKM)
insulation or jacket of Nitrile rubber (NBR)
PE-C rubber (CM)
CM, chlorinated Polyethylene
insulation or jacket of halogen-free compound
Harmonized Documents
maximal value of mutual capacitance (nF /km)
semi-conducting tape of layer
cross-linked, halogen-free polymer compound
individual stranding element (pairs or single cores etc.)
in metal foil and drain wire
several stranding elements in metalfoil and drain wire
cable with green-yellow earth core
cable with green-yellow earth core and cores with
inprinted numbers
copper-tape
inner sheath and longitudinally folded copper tape
tinsel conductor (at copper wire stranded over the
thread of synthetic bres)
corrugated aluminium sheath
in layers stranding
stranded wires conductor
laminated sheath AI-tape and PVC-jacket
laminated sheath AI-tape and PE-jacketl
double enamel coating as insulation
plastic-sheath cable
lead sheath
alloyed lead sheath
magnetic shield
VDE standard
in adapted to VDE standard
non-corrosiv, smoke-gase
natural colour
cable without green-yellow earth core

-OZ

cable without green-yellow earth core and cores with


imprinted numbers

oil-resistant
02Y
Foam-PE, insulation (cellular PE)
Q
Steel wire braiding
(R...)
round wire, diameter in mm
RAGLCompensating cable for thermocoupling
RDRhenomatic cable
RE
Computer cable
RGCoaxial cable according MIL specication
re
round, single wire
rm
round, multiwire
RScomputer switchboard cable
S
silk whipping
S
signal cables for railways
(S...)
nominal value of mutual capacitance (nF /km)
-S
signal cable for German Railway
SSwitchboard cable
SL
exible sheathed cable
2S
two layers of silk whipping
St
star quad for phantom circuits
St I
star quad in telephone cables for lager distance
St III
star quad in local cables
(St)
static screen
Staku
copper clad steel wire
Staku-Li copper clad steel stranded wires
...t
termite protection
T
supporting element for overhead cable
Tfan out cable
TF
carrier frequency of pairs or quads triple
TiC
triple in copper wire braid
TiMF
triple in metal foil
U
braiding of textile bres
VGD
gold-plated
VN
ickel-plated;
VS
silver-plated
VZK
galvanized;
VZN
tinned
W
corrugated steel sheath
W
high heat resistant
W
corrugated steel sheath
X
cross-linked polyvinylchlorid (X-PVC) or other materials
XPE
cross-linked polyethylene (X-PE)
2X
cross-linked polyethylene
7X
cross-linked Ethylentetrauorethylen (X-ETFE)
10X
cross-linked Polyvinylidenuorid (X-PVDF)
Y
PVC, polyvinylchloride
Yu
PVC, polyvinylchloride, non-ammable, ame-retardant
Yv
PVC, polyvinylchloride, with reinforced sheath
YV
Equipment wires with tinned conductor
Yw
PVC, polyvinylchlorid, heat resistant upto 90C
2Y
Polyethylene (PE)
2Yv
Polyethylene, reinforced sheath
02Y
Cellular polyethylene
02YS
insulation of cellular polyethylene with outer PE-skin
2YHO
insulation of air-spaced polyethylene
3Y
insulation polystyrene (PS), Styroex
4Y
insulation or jacket of polyamide (PA)
5Y
insulation or jacket of polytetrauorethylene (PTFE),
HELUFLON
5YX
Peruoralkoxy (PFA)
6Y
Peruoroethylene-propylene (FEP), HELUFLON
7Y
insulation or jacket of ethylentetrauorethylen (ETFE)
8Y
insulation of polyimid (PI), Kapton
9Y
polypropylen (PP)
10Y
PVDF, Polyvinylidene uoride
11Y
polyurethan (PUR)
12Y
TPE-E, TPE
13Y
TPE-EE, TPE on base of Polyester-Ester
31Y
TPE-S, TPE on base of Polystyrol
41Y
TPE-A, TPE on base of Polyamide
51Y
PFA, Peruor-Alkoxylalkane
71Y
ECTFE, Monochlortriuorethylene
91Y
TPE-O, TPE on base of Polyester-Ester
-Z
core imprinted with numbers
Z
twin cable
(Z)
high-tensile braid of steel wires
(ZG)
high-tensile element of glass bre yarn
(ZN)
high-tensile of non-metallic elements

X 14
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Conductor-diameters according
to VDE 0295 (DIN EN 60228)
The indicated values are stated in the following table containing the conductor diameters according to the
dimension of cross-sections and conductor classes in VDE 0295 (DIN EN 60228).

Single-wire round (Cu und Alu)


class 1
Nominal-crossmin-3)
section
mm2
mm

Multi stranded
wires, round
compacted (Cu)
class 2

Fine and extra-ne


copper wires

max-

max-

max-

mm

mm

mm

class 5 and 6

0,5

0,9

1,1

1,1

0,75

1,0

1,2

1,3

1,2

1,4

1,5

1,5

1,5

1,7

1,8

2,5

1,9

2,2

2,4

2,4

2,7

3,0

2,9

3,3

3,9

10

3,7

4,2

5,1

16

4,6

5,3

6,3

25

5,21)

5,72)

6,6

7,8

35

6,11)

6,72)

7,9

9,2

50

7,21)

7,82)

9,1

11,0

70

8,71)

9,42)

11,0

13,1

95

10,31)

11,02)

12,9

15,1

120

11,61)

12,42)

14,5

17,0

150

12,91)

13,82)

16,2

19,0

185

15,4

18,0

21,0

240

17,6

20,6

24,0

300

19,8

23,1

27,0

400

22,2

26,1

31,0

500

29,2

35,0

630

33,2

39,0

800

37,6

1000

42,2

1)

only for Aluminium round conductor


for mineral-insulated round conductor, only for copper
3)
min- for round Cu-conductor are not scheduled
2)

X
X 15

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Conductor resistance

(extracted from DIN VDE 0295, IEC 60228 and HD 383)

The values are extracted from DIN VDE 0295 (equivalent with the international standard IEC 60228 and HD
383), according to cross-sections and conductor classes, beginning with nominal cross-section of 0.5 mm2.
The diameters of the single wires of each bunched conductor are not permitted to exceed the maximum
stated values (ref. DIN VDE 0295), which are required to conform the maximum resistance value of the
bunched conductors at 20 C.
Nominal
cross-section

Copper conductor plain wires


(Ohm/km)

Copper conductor tinned wires


(Ohm/km)

Aluminium conductor
(Ohm/km)

mm2

Class 1 and 2

Class 5 and 6

Class 1 and 2

Class 5 and 6

Class 1 and 2

0.05

~380

~392

0.08

~237

244

0.11

~170

~175

0.126

~150

~155

0.14

~134

~138

0.22

~ 96

~ 99

0.25

~ 76

~ 79

0.34

~ 53

~ 56

0.5

36.0

39.0

36.7

40.1

0.75

24.5

26.0

24.8

26.7

1.0

18.1

19.5

18.2

20.0

1.5

12.1

13.3

12.2

13.7

2.5

7.41

7.98

7.56

8.21

4.0

4.61

4.95

4.70

5.09

6.0

3.08

3.30

3.11

3.39

10.0

1.83

1.91

1.84

1.95

3.08

16.0

1.15

1.21

1.16

1.24

1.91

25.0

0.727*

0.780

0.734

0.795

1.20

35.0

0.524*

0.554

0.529

0.565

0.868

50.0

0.387*

0.386

0.391

0.393

0.641

70.0

0.268*

0.272

0.270

0.277

0.443

95.0

0.193*

0.206

0.195

0.210

0.320

120.0

0.153*

0.161

0.154

0.164

0.253

150.0

0.124*

0.129

0.126

0.132

0.206

185.0

0.0991

0.106

0.100

0.108

0.164

240.0

0.0754

0.0801

0.0762

0.0817

0.125

300.0

0.0601

0.0641

0.0607

0.0654

0.100

400.0

0.0470

0.0486

0.0475

0.0495

0.0778

500.0

0.0366

0.0384

0.0369

0.0391

0.0605

630.0

0.0283

0.0287

0.0286

0.0292

0.0469

class 1 = single core conductor for single and multi core cables
class 2 = multi core conductors for single and multi core cables
class 5 = ne wire copper conductors for single and multi core cables
class 6 = extra ne wire copper conductors for single and multi core cables
* for mineral-insulated cables (class 1 up to 150 mm2)

X 16
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Strand make-up

(acc. to DIN VDE 0295, IEC 60228 and HD 383)

The number of wires in columns 3-7 is not binding. According to DIN VDE 0295 is the maximum single wire diameter for the
construction of the conductor cross section and the maximum conductor resistance value shall prevail.
stranded
wires

multistranded ne
wires
wires

class 2
DIN VDE 0295
column 1

extra-ne wires

class 5
DIN VDE 0295
column 2

class 6
DIN VDE 0295

column 3

3)

column 4

1)

2)

1)

2)

cross
Number sngle Number single Number single Number single
section of wires x wire of wires x wire of wires x wire of wires x wire
mm2
mm
mm
mm
mm

column 5

column 6

1)

1)

Number single Number single


of wires x wire of wires x wire
mm
mm
14 x 0,07

0,05
0,08
0,09
0,14
0,25
0,34
0,38
0,5
0,75
1,0
1,5
2,5
4

7 x 0,30
7 x 0,37
7 x 0,43
7 x 0,52
7 x 0,67
7 x 0,85

6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

7 x 1,05
7 x 1,35
7 x 1,70
7 x 2,13
7 x 2,52
19 x 1,83
19 x 2,17
19 x 2,52
37 x 2,03
37 x 2,27
37 x 2,52
37 x 2,87
61 x 2,50
61 x 2,89
61 x 3,23
91 x 2,97

7 x 0,25
7 x 0,27
7 x 0,30
7 x 0,37
7 x 0,43
7 x 0,52
19 x 0,41
19 x 0,52
19 x 0,64
49 x 0,51
49 x 0,65
84 x 0,62
133 x 0,58
133 x 0,69
189 x 0,69
259 x 0,69
336 x 0,67
392 x 0,69
494 x 0,69
627 x 0,70
790 x 0,70

18 x 0,1
14 x 0,15
19 x 0,15
12 x 0,2
16 x 0,2
24 x 0,2
32 x 0,2
30 x 0,25
50 x 0,25
56 x 0,3
84 x 0,3
80 x 0,4
128 x 0,4
200 x 0,4
280 x 0,4
400 x 0,4
356 x 0,5
485 x 0,5
614 x 0,5
765 x 0,5
944 x 0,5
1225 x 0,5
1530 x 0,5
2035 x 0,5
1768 x 0,6
2228 x 0,6

* Alternative: 19x0,08
1)
The number of individual wires are without obligation.
2)
The diameters of the single wires for each conductor are
not allowed to exceed the values stated to DIN VDE 0295.
The single wires of a stranded conductor must have all
the same nominal diameters.
3)
Minimum-number of single wires of stranded conductor
(up to 35 mm2). The single wires of a stranded conductor must
have all the same nominal diameters.

18 x 0,1
32 x 0,1
42 x 0,1
21 x 0,15
28 x 0,15
42 x 0,15
56 x 0,15
84 x 0,15
140 x 0,15
224 x 0,15
192 x 0,2
320 x 0,2
512 x 0,2
800 x 0,2
1120 x 0,2
705 x 0,3
990 x 0,3
1340 x 0,3
1690 x 0,3
2123 x 0,3
1470 x 0,4
1905 x 0,4
2385 x 0,4

2)

24 x 0,07*
36 x 0,07
65 x 0,07
88 x 0,07
100 x 0,07
131 x 0,07
195 x 0,07
260 x 0,07
392 x 0,07
651 x 0,07

18 x 0,1
32 x 0,1
42 x 0,1
48 x 0,1
64 x 0,1
96 x 0,1
128 x 0,1
192 x 0,1
320 x 0,1
512 x 0,1
768 x 0,1
1280 x 0,1
2048 x 0,1
3200 x 0,1

column 7
Number1) single
of wires x wire
mm
26 x 0,05
40 x 0,05
72 x 0,05
128 x 0,05
174 x 0,05
194 x 0,05
256 x 0,05
384 x 0,05
512 x 0,05
768 x 0,05
1280 x 0,05

1040 x 0,07
1560 x 0,07
2600 x 0,07

permissible maximal diameter of single wires:


nominal value
maximal value
mm
mm

Note:

0,2
0,25
0,3
0,4
0,5
0,6

0,21
0,26
0,31
0,41
0,51
0,61

Conversion AWG to (mm2)


AWG

mm2

AWG

mm2

AWG

mm2

kcmil

mm2

30
28
26
24
22
21
20

0,05
0,08
0,14
0,25
0,34
0,38
0,50

18
17
16
14
12
10
8

0,75
1,00
1,50
2,50
4
6
10

6
4
2
1
2/0
3/0
4/0

16
25
35
50
70
95
120

300 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil

150
185
240
300
400
500

This cross reference list shows equivalent nominal values. Actual cross sections may vary. The AWG values are approximate, if the cables
are made to European Standards (mm2) and vice versa. In critical applications, where the current reaches upper limits. The deviating
operation conditions for installation and laying according to standards are to be taken into consideration.

X 17
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Nominal voltage and Operating voltage


Nominal voltage
Voltage of cables and wires, by which the construction and the tests in respect of electrical characteristics
are to be refered.
According to DIN VDE 0298 and IEC 183 the cables are specied U0/U, where
U0 = cable nominal voltage between the conductor and the metal covering or earth and
U = cable nominal voltage between the phase conductors, for 3-phase U = 3 U0.
According to IEC regulations, the maximum permissible voltage Um is given in brackets. The identication is:
U0/U (Um).
As the insulation of plastic insulated cables are measured with a nominal voltage U0/U = 0,6/1 kV and all
radial eld cables for the voltage U0, these cables are suitable for installation:
in single phase systems, in which the both phase conductors are insulated, with nominal voltage UN = 2 U0
in single phase systems, in which one phase conductor is earthed, with the nominal voltage UN = U0

Operating voltage
Voltage between conductors of a power system or between a conductor and earth under specied
condition in a given time during an undisturbed operation.
Coordination of cable-Nominal voltages
Nominalvoltages
U0/U
kV

for
3-phase
system
kV

for 1-phase alternating current


both phase conductors
one phase conductor
insulated
earthed
kV
kV

0,6/1

1,2

0,6

3,6/6

7,2

3,6

6/10

10

12

12/20

20

24

12

18/30

30

36

18

Coordination of maximum permissible Operating voltages


Nominal
voltages
U0/U
kV

maximum
voltage
for 3-phase system
kV

maximum voltage for 1-phase alternating current


both phase conductors
one phase conductor
insulated
earthed
kV
kV

0,6/1

1,2

1,4

0,7

3,6/6

7,2

8,3

4,1

6/10

12

14

12/20

24

28

14

18/30

36

42

21

Note:
Cable with U0/U 0,6/1 kV is allowed for Direct Current Systems, of those the maximum operating voltage
conductor/conductor 1,8 kV or conductor/earth 0,9 kV not to be exceeded.

X 18
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Current carrying capacity and indications


for calculation of Power Cables and Wires
The guidelines for current carrying capacities of copper and aluminium are valid DIN VDE 0298 part 4 as
well as DIN VDE 0276 part 603 and for the conversion factors DIN VDE 0276 part 1000.
The current carrying capacity of a cable should limited in such a degree that at all locations in a cable
system which causes the generated heats under given proportions to lead safely in the environment.
The heat ow depends on the inner heat-resistance between conductor and outer surface of the cable and
as well as from the heat emission to the surroundings.
The following recommended values are the current carrying capacity of cables for laying in earth and in air
at normal operating conditions. Hints for the deviated operating conditions, see DIN VDE 0298 table 4 and
DIN VDE 0276 part 603 and part 1000.

Indications for Calculation


For laying in earth
Deviating operating conditions with both conversion factors are to be considered, as these depend on
both of specic heat-resistance and the grade of load.
EVU-load (load grade) is the maximum load factor of 0,7. The conversion factors for the load grades 0,5,
0,6, 0,85 and 1,0 are to be taken in tables DIN VDE 0276 part 603 and part 1000. Intermediate values can
be interpolate (1,0 used for permanent load).
Laying depth 0,7 m. The load capacity decreases with increasing of the laying depth. Usual depth of laying
is 0,7 to 1,2 m.
As normal value of the specic ground thermal resistivity in moist areas is selected with 1,0 K m/W . For
dry areas the choiced value is 2,5 K m/W, under consideration of the applied usual bedding materials of
sands.
For favourable ground conditions or with thermal resisted bedding materials, lower value under well
consolidation can be achieved. For individual case, the values and upon that the resulted current carrying
loads are to be determined.
For laying in air
The values stated in the tables for outdoor laying in the air are dened for permanent operation.
The arrangement of the cables is corresponded the presentation in table 3, DIN VDE 0276 part 1000.
Conversion factors for other laying conditions and the heaping of cables are shown in table 10 and 11,
DIN VDE 0276 part 1000.
The current carrying capacities of multi-core cables can be calculated by using the current load value for
3-core cables according to table 13 with help of the conversion factors.
By using the cable channels or cable board underlays etc. the air temperature will be increased. In this
case the conversion factors according to table 12 for deviating air temperature should be used.
For outdoor installation in air, the ambient temperature is based on 30 C.
Radiation of heats and solar inuence must be taken into consideration, where a good air circulation is
needed.
A sufcient large distance is to retain between the cables and the heating elements, because badly
insulated heating elements often raise additionally the temperature of the cable.
Distance between the cable from the wall, oor or ceiling

= 2 cm

Distance between the cables being laid one above the other

= 2xD

Distance between the cable systems being laid one above the other

= 20 cm

Distance between the cables being laid side by side

= 2xD

Specic ground
very moist area
moist area
dry area
very dry area

thermal resistivity
= 0,7 K m/W
= 1,0 K m/W
= 2,0 K m/W
= 3,0 K m/W

X
X 19
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Installation Methods and Operating Conditions


Power cables and insulated wires for xed installation
Installation method type A1
Single core cables in insulation tube in a thermally insulated wall.

Installation method A2
Multicore cables or multicore plastic sheathed cables in the insulation tube in a thermally insulated wall,
whereby the walls for the methods of installation employed comprise an outer weatherproof board,
thermal insulation and an inner board of wood or materials similar to wood, having a temperature lag
of 0,1 m2 K/W. The plastic or metal insulation tube is mounted such that this is very close to the inner
wall without actually being in conduct with the wall.

Installation method B1
Single core cables in insulation tube on a wooden wall.

Installation method B2
Multicore cables or multicore plastic-sheathed cables in insulation tube on a wooden wall.
For both installation methods, the insulation tube must be secured such that the space between conduit
and the wall surface is less than 0,3 times the diameter of the insulation tube. The plastic or metal
insulation tube can be installed directly on the masonry construction or plastered surface, whereby the
current carrying capacity of the cables or wires can then be higher.
This problem is still being investigated by CENELEC.

Installation method C
Single core or multicore cables, or single core or multicore plastic-sheathed cables, on a wooden wall.
The cables or insulated wires shall be mounted such that the space from the wall surface is less than 0,3
times the outer diameter of the cable or insulated wire. The current carrying capacity can be increased
when installed directly on or in the masonry construction as well as underneath the plaster.
This problem is still being investigated by CENELEC.

Installation methods E, F and G


Single core or multicore cables, or single core or multicore plastic-sheathed cables, installed in the open air.
The cable or insulated wire shall be installed such that the dissipation of heat is not impeded, whereby
allowance shall be made for heating by other sources and for irradiation by sunshine. Natural convection
shall not be obstructed. The space from the cable or insulated wire by each bordering surface shall be
0,3 times that of the outside diameter. A space equal to that of the outside diameter is sufcient for
single core cables and plastic-sheathed wires in order to meet the current carrying requirements for an
installation in the open-air.

X 20
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Laying Conditions for Power Cables


As laying depth, the mathematical distance to the cable axis for tringular bunched laying the distance of
the bundle axis to the earth surface with 70 cm is choised. With increased laying depth the load ratings will
be mathematically reduced. Hereby the same temperature and the same thermal earth resistances are to
be presumed.
Normal operation conditions and indications for deviating operation conditions.

Normal operation conditions


Laid in Earth

Laid in Air

Indications

1 Multicore cable

1 Multicore cable

Conversions factors see


the following tables

1 Single core cable


in direct currentsystem

1 Single core cable


in direct current system

as of collective laying conditions


see the following tables

3 Single core cables


in 3-phase system,
side by side, with a
space of 7cm

3 Single core cables


in 3-phase system,
side by side, with a
space of a cable

3 Single core cables


in 3-phase system,
in bundle form1)

3 Single core cables in


3-phase system
in bundle form1)

Bedding in sand or
earth shove and if
necessary covering
with bricks, cement
plates or with at to
light curved thin
covering of plastic

Laid in open air, i.e. unhindered heat radiation will


be ensured at:
Distance of cable from wall,
oor or ceiling  2 cm

Conversion factors
for laying in earth:
covering hood with air
cavat y = 0,9
laid in conduit = 0,85

For cables laying


side by side:
Space at least two
times of the cable

Conversion factors
for laying in air:
alternating ambient
temperatures
as of collecting laying
conditions
for laying in conduits
see tables and
indications according
to DIN VDE 0298

Ambient conditions
Ground temperature at
installation depth: 20C
Soil-thermal resistivity
of moist area: 1,0 K m/W
Soil-thermal resistivity
of dry area: 2,5 K m/W

Connecting and earthing


of metal sheaths or screens
on both ends

For cables laying one above the


other:
Vertical space of the cable
atleast two times of the cable
cable length at least 30 cm
Consideration of thermal
loss in cable, the increased
air temperature of sufcient
big and ventilated
rooms
Protection against direct
heatradiation of sunlight etc.
Air temperature 30C
Adequate big or ventilated rooms,
due to that the power loss of
the cable not be noticeable
increased
Connecting and earthing of
metal sheaths or screens on
both sides

1)

in bunched or triangle touching


arrangement

X
X 21

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Current ratings for installation

A1, A2, B1 and B2

Cables for xed installation within buildings


Operating temperature at conductor 70C; Ambient temperature 30C
Type Designation

H07V-U, -R, -K
H07V3-U, -R, -K

NYM, NYMZ, NYMT


NHYRUZY, NYBUY
NYDY
N05VV-U, N05VV-R
NHXMH
NYY, NYCY 1)

H07V-U, -R, -K
H07V3-U, -R, -K

NYM, NYMZ, NYMT


NHYRUZY, NYBUY
NYDY
N05VV-U, N05VV-R
NHXMH
NYY, NYCY 1)

Installation:
in thermally
insulated walls
in insulating tubes

Single core cables


in insulating tubes,
in a thermally insulated
walls

Multicore sheathed
cables in insulating
tubes, in a thermally
insulated walls

Single core cables


in insulating tubes
on a wall

Multicore cables or
multicore sheathed
cables in insulating
tubes oa a wall

Installation in thermally insulated walls

Installation in insulating tubes

Installation method2)

A1

B1

Nuber of loaded cores

A2
3

Cross-section, mm2

B2
3

Current ratings in Ampere (A)

1,5

15,53)

13,5

15,53)

13,0

17,5

15,5

16,5

15,0

2,5

19,5

18,0

18,5

17,5

24

21

23

20

26

24

25

23

32

28

30

27

34

31

32

29

41

36

38

34

10

46

42

43

39

57

50

52

46

10

47,174)

16

61

56

57

52

76

68

69

62

25

80

73

75

68

101

89

90

80

35

99

89

92

83

125

110

111

99

50

119

108

110

99

151

134

133

118

70

151

136

139

125

192

171

168

149

95

182

164

167

150

232

207

201

179

120

210

188

192

172

269

239

232

206

150

240

216

219

196

185

273

245

248

223

240

320

286

291

261

300

367

328

334

298

Conversion factors for deviating ambient temperature, grouping, installation under the ceiling, multicore cables and insulated wires
see DIN VDE 0298 part 4.

1)
2)
3)
4)

The current ratings are valid for cables with concentric conductor, only for multicore versions
for further installation methods see DIN VDE 0298 part 4
see DIN VDE 0298 part 4
not permitted for the installation on a wooden wall and not for application of the conversion factors, see DIN VDE 0298 part 4

X 22
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Current ratings for installation conditions C, E, F and G


Cabel for xed installation within buildings
Operating temperature at conductor 70C; Ambient temperature 30C
Type designation

NYM, NYMZ, NYMT, NYIF, NYIFY


NHYRUZY, NYBUY, NYDY
N05VV-U, N05VV-R
NHXMH, NYY, NYCY 1)

NYY

Installation:
directly
in open air

Singlecore or multicore
cables or single or
multicore sheathed
cables on a wall

Single core cables or single core sheathed cables with a


space of minimum 1 x diameter d to wall

Multicore cables or
multicore sheathed
cables with a space of
minimum 0,3 x diameter d to wall

with contact

or

or

direct installation
2)

installation method

Number of loaded
cores

with gap d

installation in open air


E

F
3

Cross-section, mm2

Current ratings in Ampere (A)

1,5

19,5

17,5

22

18,5

2,5

27

24

30

25

36

32

40

34

33,023)

46

41

51

43

10

63

57

70

60

10

59,433)

16

85

76

94

80

25

112

96

119

101

131

114

110

146

130

35

138

119

148

126

162

143

137

181

162

50

168

144

180

153

196

174

167

219

197

70

213

184

232

196

251

225

216

281

254

95

258

223

282

238

304

275

264

341

311

120

299

259

328

276

352

321

308

396

362

150

344

299

379

319

406

372

356

456

419

185

392

341

434

364

463

427

409

521

480

240

461

403

514

430

546

507

485

615

569

300

530

464

593

497

629

587

561

709

659

400

754

689

656

852

795

500

868

789

749

982

920

630

1005

905

855

1138

1070

Conversion factors for deviating ambient temperature, grouping, installation under the ceiling, multicore cables and insulated wires see
DIN VDE 0298 part 4.

1)
2)
3)

The current ratings are valid for cables with concentric conductor, only for multicore versions
for further installation methods see DIN VDE 0298 part 4
see DIN VDE 0298 part 4

X
X 23

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Current ratings for installation conditions


Cables for xed installation within buildings

A1, A2, B1 and B2

Operating temperature at Conductor 90C; Ambient temperature 30C


Type designation

H07V2-U, -K
NHXA, NHXAF
H07Z-U, -R, -K

NI2XY, N2XY, N2X2Y


N2XH, N2XCH
NHXHX FE180
NHXCHX FE180
NHXH FE180
NHXCH FE180
NHXHX, NHXCHX

H07V2-U, -K
NHXA, NHXAF
H07Z-U, -R, -K

NI2XY, N2XY, N2X2Y


N2XH, N2XCH
NHXHX FE180
NHXCHX FE180
NHXH FE180
NHXCH FE180
NHXHX, NHXCHX

Installation:
in thermally
insulated walls
in insulating tubes

Single core cables


in insulating tubes
in a thermally insulated
walls

Multicore sheathed
cables in insulating
tubes, in a thermally
insulated walls

Single core cables


in insulating tubes
on a wall

Multicore cables or
multicore sheathed
cables in insulating
tubes on a wall

Installation in thermally insulated walls

Installation in insulating tubes

Installation method1)

A1

B1

Number of loaded cores

A2
3

Cross-section, mm2

B2
3

Current ratings in Ampere (A)

1,5

19,0

17,0

18,5

16,5

23

20

22

19,5

2,5

26

23

25

22

31

28

30

26

35

31

33

30

42

37

40

35

45

40

42

38

54

48

51

44

10

61

54

57

51

75

66

69

60

16

81

73

76

68

100

88

91

80

25

106

95

99

89

133

117

119

105

35

131

117

121

109

164

144

146

128

50

158

141

145

130

198

175

175

154

70

200

179

183

164

253

222

221

194

95

241

216

220

197

306

269

265

233

120

278

249

253

227

354

312

305

268

150

318

285

290

259

185

362

324

329

295

240

424

380

386

346

300

486

435

442

396

Conversion factors for devating ambient temperature, grouping, installation under the ceiling, multicore cables and insulated wires
see DIN VDE 0298 part 4 .

1)

for further installation conditions see DIN VDE 0298 part 4

X 24
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Current ratings for installation conditions


Cables for xed installation within buildings

C, E, F and G

Operating temperature at conductor 90C; Ambient temperature 30C


Type designation

NI2XY, N2XY, N2X2Y


N2XH, N2XCH1)
NHXH FE180, NHXCH FE1801)
NHXHX FE180, NHXCHX FE1801)
NHXHX, NHXCHX1)

Installation:
directy
in open air

Singlecore or multicore
cables or single or
multicore sheathed
cables on a wall

NI2XY, N2XY, N2X2Y


N2XH
NHXH FE180
NHXHX FE180
NHXHX

Multicore cables or
Single core cables or single core sheathed cables with a
multicore sheathed
space of minimum 1 x diameter d to wall
cables with a space of
with gap d
minimum 0,3 x diameter with contact
d to wall

or
or

direct installation
Instalation method2)

Number of loaded
cores

installation in open air


E

F
3

Cross-section, mm2

G
3

Current ratings in Ampere (A)

1,5

24

22

26

23

2,5

33

30

36

32

45

40

49

42

58

52

63

54

10

80

71

86

75

16

107

96

115

100

25

138

119

149

127

161

141

135

182

161

35

171

147

185

158

200

176

169

226

201

50

209

179

225

192

242

216

207

275

246

70

269

229

289

246

310

279

268

353

318

95

328

278

352

298

377

342

328

430

389

120

382

322

410

346

437

400

383

500

454

150

441

371

473

399

504

464

444

577

527

185

506

424

542

456

575

533

510

661

605

240

599

500

641

538

679

634

607

781

719

300

693

576

741

621

783

736

703

902

833

400

940

868

823

1085

1008

500

1083

998

946

1253

1169

630

1254

1151

1088

1454

1362

Conversion factors for deviating ambient temperature, grouping, installation under the ceiling, multicore cables and insulated wires
see DIN VDE 0298 part 4.

1)
2)

The current ratings are valid for cables with concentric conductor, only for multicore versions
for further installation methods see DIN VDE 0298 part 4

X
X 25

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Current ratings for cables and insulated wires


up to 1000 V and heat resistant cables
Permissible operating temperature at conductor 40C to 180C as
per type Ambient temperature 30C to 150C, as per type
Type designation

H05V-U, -K
H07V-U, -R, -K
H07V3-U, -R, -K
N05XAFX, N07XAFX
NFYW
H05RN-F, H07RN-F

H03RT-F, A03RT-F
H05RR-F, A05RR-F,
A05RRT-F
H05RN-F, A05RN-F
H05RNH2-F
H07RN-F, A07RN-F

H05V2-U, H05V2-K
H07V2-U, H07V2-K
H05Z-U
H07Z-U, -R, -K
NHXA, NHXAF
H05G-U, H05G-K
H07G-U, -R, -K
N7YA, N7YAF
N2GFA, N2GFAF
H05S-U, H05S-K
H05SJ-K, A05SJ-U, -K
H07ZZ-F

H03VH-Y1), H03VH-H
H03VV-F, A03VV-F,
H03VVH2-F
H05VV-F, A05VV-F,
H05VVH2-F
H03VVH8-F
H03VVH2H8-F
H05VVH8-F
H05VVH2H8-F
H07ZZ-F

Installation:
in open air
upon or on surface

in open air

Number of loaded
cores

2)

JZ-500, -JB, -OZ, -OB


JZ-600, -CY, JZ-750
SY-JZ, -JB
JZ-602, -CY, -RC, -RC-CY
JZ-HF, -CY, PUR -JZ
F-C-PUR-JZ, Y-C-PUR-JZ
PUR-750, PUR-JZ-HF, -CY
MULTIFLEX 512 PUR, C-PUR
PUR-ORANGE, YELLOW
PUR-C-PUR
TRONIC () 0,5mm2)
TRONIC-CY () 0,5mm2)
F-CY-JZ, -OZ, Y-CY-JZ
THERM 120
JZ-500 HMH, -C
BAUFLEX, MULTIFLEX-PLUS
Lift-Hoist cable
Lift-2S, PVC-Flat, -CY
NEO-Flat, -CY
TOPSERV, TOPFLEX

upon or on surface

Cross-section, mm2
0,5

NPL, NMHCU, NYMHYV


NSHCU, NGFLGU,
NSHTU
H05RTD5-F, H05RND5-F
H05RTD3-F, H05RND3-F
H07RTD5-F, H07RND5-F
H07RTD3-F, H07RND3-F
H07RN-F, A07RN-F
NYMH11Y, NGMH11Y
H05VVH6-F, H05VVD3H6-F
H07VVH6-F, H07VVD3H6-F
A07VVH6-F, A07VVD3H6-F
NXMHX
H05VV5-F, H05VVC4V5-K
NYSLY, NYSLYCY
NLSY, NLSCY
NSY, NSCY
NYPLYW, NYFAZW
N2GSA, N2GMH2G

2 or 3

Current ratings in Ampere (A)

0,75

15

12

12

19

10

10

15

15

1,5

24

16

16

18

18

2,5

32

25

20

26

26

42

32

25

34

34

54

40

44

44

10

73

63

61

61

16

98

82

82

25

129

108

108

35

158

135

135

50

198

168

168

70

245

207

207

95

292

250

250

120

344

292

292

150

391

335

335

185

448

382

382

240

528

453

453

300

608

523

523

400

726

500

830

Conversion factors for deviating ambient temperature, grouping, installation under the ceiling, multicore cables and insulated
wires see DIN VDE 0298 part 4.
1)
2)

Nominal cross-sectional area 0,1 mm2, loadable with 0,2 A, independent of the ambient temperature
The current ratings are valid for the application of household equipment conductor cross-section 0,34 mm2 see table page X 28

X 26
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Current ratings for cables  0,6/1kV

Special rubber-insulated single core cables, multicore rubber cables


and trailing cables
Operating temperature at conductor 90C (80C); Ambient temperature 30C
Type designation

NSGAU, NSGAFU
NSHXA, NSHXAF1)

NSGAU, NSGAFU
NSGAFCMU
NSHXA, NSHXAF
NSHXAFCM1)
3,6/6 kV

NSSHU
NT...

NT...

up to 6/10 kV

 6/10 kV

Nominal voltage

0,6/1 kV and 1,8/3 kV

Permissible operating
temperature at conductor

90C

Recommended operating
temperature

80C

Installation in open air

Installation upon or on surface

Installation::
in open air
upon or on surface

Number of loaded cores


Cross-section, mm

Current ratings in Ampere (A)

1,5

30

32

2,5

41

43

30

55

56

41

70

71

53

10

98

99

74

16

132

133

99

105

25

176

174

131

139

35

218

215

162

172

50

276

270

202

215

70

347

338

250

265

95

416

403

301

319

120

488

473

352

371

150

566

546

404

428

185

644

622

461

488

240

775

540

300

898

Conversion factors for deviating ambient temperature, grouping, installation under the ceiling, multicore cables and insulated wires
see DIN VDE 0298 part 4.

1)

when a bunched installation with single cores or multi-cored cables are used on oor the conversion factors for the rating values should be considered see table page X 34
factor 0,76 for one-phase a.c. and direct current circuits or
factor 0,67 for three-phase circuits, is to be multiplied.
when a bunched installation with single cores or multi-cored cables are used in open air, or cable trays, the conversion factors for the rating values should be considered
see table in page X 36
factor 0,8 for one-phase a.c. and direct current circuits or
factor 0,7 for three-phase circuits, is to be multiplied.
when a bunched installation with single cores or multi-cored cables are used in insulating tubes or conduits, the conversion factors for the rating values should be considered
see table page X 34
factor 0,61 for one-phase a.c. and direct current circuits or
factor 0,54 for three-phase circuits, is to be multiplied.

X 27
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Current ratings (general)

for exible cables,


for non-existing cable types in the previous tables
The indicated values stated in the following table considered as guiding values in an abbreviate form, extracted from DIN VDE 0298
part 4 and DIN VDE 0100 part 430. In critical situation the DIN VDE recommendations should be considered.
For industrial machines the DIN VDE 0113, part 1 (EN 60204 part 1/IEC 204-1) is valid; for telephone and information systems
DIN VDE 0891 part 1; for telephone aerial cables DIN VDE 0891 part 8 and for at cables DIN VDE 0891 part 10. General terms and
recommendated values are contained in DIN VDE 0298 part 2 and part 4.
Power rating values for 1,5120 mm2 (group 3 up to 35 mm2) according to DIN VDE 0100 part 430 at an

Ambient temperature up to 30C


Nominal
crosssection

Group 1
power rating

mm2
0,05
0,14
0,25
0,34
0,5
0,75
1
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
group 1

group 2

A
1
2
4
6
9
12
15
18
26
34
44
61
82
108
135
168
207
250
292
335
382

Group 2
protective fuse

Group 3

power rating

10
16
25
25
35
50
80
100
125
160
200
250
250
315
355

A
1
2
4,5
6
9
12
15
18
26
34
44
61
82
108
135
168
207
250
292
335
382
453
523

protective fuse
A

10
10
16
25
25
35
50
63
80
100
125
160
200
250
315
355
425
500

One or more single core cables and insulated wires laid in


group 3
duct i. e. PVC-sheathed single cores H 03V. ./H 05V. ./H 07V. .
according to VDE 0281.
Multi core cables, i. e. light PVC-sheathed cables, exible
cables, metal-clad wiring cables in open or ventilated conduits.

power rating
A
2
3,5
6
9
12
15
19
24
32
42
54
73
98
129
158
198
245
292
344
391
448
528
608
726

protective fuse
A

10
16
20
25
35
50
63
80
100
125
160
200
250
315
355
400
500
600
630

Single core cables, laid open in air with a


spacing at least equal to cable diameter,
such as single core wirings for switch- and
distribution cabinets and rail line distributors.

Conversion factors*) for deviating ambient temperatures:


Ambient temperature over 30C

Ambient
temperature
C
over 30 bis 35
over 35 bis 40
over 40 bis 45
over 45 bis 50
over 50 bis 55
over 55 bis 60
over 60 bis 65

Conversion factors, applied to


the above current ratings table
Rubber insulation PVC insulation
Permissible operating Permissible operating
temp. at conductor
temp. at conductor
Conversion factors
Conversion factors
up to 60C
up to 70C
0,91
0,94
0,82
0,87
0,71
0,79
0,58
0,71
0,41
0,61

0,50

0,35

* Further informations see page X 35.

Ambient temperature over 50C (heat-resistant)


Conversion factors, applied to
the above current ratings table
Permissible operating temperture Permissible operating temperture
at conductor
at conductor
Conversion factors up to 90C
Conversion factors up to 110C
over 50 bis 55
0,94
over 50 bis 55
1,00
over 55 bis 60
0,87
over 55 bis 60
1,00
over 60 bis 65
0,79
over 60 bis 65
1,00
over 65 bis 70
0,71
over 65 bis 70
1,00
over 70 bis 75
0,61
over 70 bis 75
1,00
over 75 bis 80
0,50
over 75 bis 80
1,00
over 80 bis 85
0,35
over 80 bis 85
0,91
over 85 bis 90

over 85 bis 90
0,82
over 90 bis 95
0,71
over 95 bis 100
0,58
over 100 bis 105
0,41
over 105 bis 110

X 28
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Current ratings for HELUTHERM 145


For permanent operating to the ambient temperature of 30 C. Conversion factors for the deviating site
operation conditions see tables below.
Sufciently large or ventilated rooms in which the ambient temperature is not noticeably increased by the
heat losses from the cables. Protection should be taken from the solar radiation etc.
Installation

Conversion factors
for grouping

in open air

on face without
inter-contact

on surface with
inter-contact

in tubes, conduites,
cabinets

to table 1

to table 2

to table 3

Cross-section, mm2

Current ratings in Ampere (A) up to 30 C ambient temperature

0,25

13

12

0,33

17

15

11

0,50

19

18

12

10

0,75

24

23

17

13

1,0

31

30

20

17

1,5

39

36

25

20

2,5

51

48

33

26

68

65

45

36

88

84

58

46

10

121

116

80

64

16

160

152

106

85

25

211

200

140

111

35

261

248

172

138

50

320

304

211

169

70

411

391

272

217

95

502

476

331

265

120

587

558

387

310

150

680

646

449

359

185

781

743

516

413

240

931

884

614

492

Conversion factors for grouping


Number of single core cables
for 2-phase or 3-phase systems

10

12

Table 1

Factor

1,00

0,94

0,90

0,90

0,90

0,90

0,90

0,90

0,90

0,90

0,90

Table 2

Factor

1,00

0,85

0,79

0,75

0,73

0,72

0,72

0,71

0,70

Table 3

Factor

1,00

0,80

0,70

0,65

0,60

0,57

0,54

0,52

0,50

0,48

0,45

Conversion factors for deviating ambient temperatures


Temperature in C

20

30

40

50

60

70

80

90

95

100

105

110

115

Factor

1,05

1,00

0,94

0,88

0,82

0,75

0,67

0,58

0,53

0,47

0,41

0,35

0,24

X 29
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Current ratings for silicone cables and wires


The indicated values stated in the following table are considered as guiding values. These are to be
selected each particularly for the individual application.
Heat-resistance at an ambient temperature up to 150C
Group 1
Nominalcrosssection

current-carrying
capacity
A

Group 2

protective
fuse
A

current-carrying
capacity
A

Group 3

protective
fuse
A

current-carrying
capacity
A

protective
fuse
A

0,25

2,8

0,5

10

0,75

12

15

10

1,0

12

10

15

10

19

20

1,5

16

16

18

16

24

25

2,5

21

20

26

25

32

35

28

25

34

35

42

50

36

35

44

50

54

63

10

49

50

61

63

73

80

16

65

63

82

80

98

100

25

85

83

108

100

129

125

35

105

100

135

158

160

50

140

125

168

198

200

70

175

160

207

245

250

95

210

200

250

292

300

120

250

250

292

344

335

150

335

391

185

382

448

240

453

528

300

523

608

Group 1: One or more single core cables laid in duct.


Group 2: Multicore cables, exible cables laid in open or ventilated conduits.
Group 3: Single core cables laid in open air with a spacing at least equal to cable diameter.

Power ratings for


ambient temperature over 150C
The following conversion factors are valid:
Temperature
C

current-carrying
capacity values in %

up to 150

100

over 150 to 155

91

over 155 to 160

82

over 160 to 165

71

over 165 to 170

58

over 170 to 175

41

X 30
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Current ratings for NYY, NAYY, NYCY, NYCWY,


NAYCWY 0,6/1 kV
Current carrying capacity in Ampere (A), laying in ground (20C) according to DIN VDE 0276 part 603, cyclic loading, load factor 0,7 2)

Nominal
Crosssection
mm2

Copper conductor
NYY

NYCWY

NAYY

NAYCWY

1)

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
1)

Aluminium conductor

30
39
50
62
83
107
138
164
195
238
286
325
365
413
479
541
614
693
777
859
936

27
36
47
59
79
102
133
159
188
232
280
318
359
406
473
535
613
687

41
55
71
90
124
160
208
250
296
365
438
501
563
639
746
848
975
1125
1304
1507
1715

1)

31
40
51
63
84
108
139
166
196
238
281
315
347
385
432
473
521
574
636

27
36
47
59
79
102
133
160
190
234
280
319
357
402
463
518
579
624

106
127
151
185
222
253
284
322
375
425
487
558
635
716
796

102
123
144
179
215
245
275
313
364
419
484
553

160
193
230
283
340
389
436
496
578
656
756
873
1011
1166
1332

108
129
153
187
223
252
280
314
358
397
441
489
539

103
123
145
180
216
246
276
313
362
415
474
528

Rated current for direct current systems with a far-distanced return conductor

Current carrying capacity in Ampere (A), laying in air (30C)

Nominal
Crosssection,
mm2

Copper conductor
NYY

NYCWY

NAYY

NAYCWY

1)

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
1)

Aluminium conductor

21
28
37
47
64
84
114
139
169
213
264
307
352
406
483
557
646
747
858
971
1078

19,5
25
34
43
59
79
106
129
157
199
246
285
326
374
445
511
597
669

27
35
47
59
81
107
144
176
214
270
334
389
446
516
618
717
843
994
1180
1396
1620

1)

22
29
39
49
67
89
119
146
177
221
270
310
350
399
462
519
583
657
744

Rated current for direct current systems with a far-distanced return conductor

19,5
26
34
44
60
80
108
132
160
202
249
289
329
377
443
504
577
626

2)

87
107
131
166
205
239
273
317
378
437
513
600
701
809
916

82
100
119
152
186
216
246
285
338
400
472
539

110
135
166
210
259
302
345
401
479
555
653
772
915
1080
1258

91
112
137
173
212
247
280
321
374
426
488
556
628

83
101
121
155
189
220
249
287
339
401
468
524

Denition of load factor s. DIN VDE 0276 part 603, table 16

Conversion factors for multicore cable ( 5 cores)


The conversion factors are to be used for laying the cables in ground or in air, to the values given in above tables.

Number of
loaded cores
n

laying
in ground
f

laying
in air
f

5
7
10
14
19
24
40
61

0,70
0,60
0,50
0,45
0,40
0,35
0,30
0,25

0,75
0,65
0,55
0,50
0,45
0,40
0,35
0,30

Note: valid for cross-section 1,5 to 10 mm2

X 31
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Current ratings for N2XY, NA2XY, N2XCY,


NA2XCY 0,6/1 kV
Current carrying capacity in Ampere (A), laying in ground (20C), cyclical movement load factor 0,7.

Insulation material
Permissible operating
temperature

VPE
90 C
N2XY

N2XCY

NA2XY

NA2XCY

1)

Nominal-Cross-section
in mm
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
1)

33
42
54
67
89
115
148
177
209
256
307
349
393
445
517
583
663
749
843
935
1023

Copper conductor, rated current in A


31
48
33
40
63
43
52
82
55
64
102
68
86
136
91
112
176
117
145
229
150
174
275
179
206
326
211
254
400
257
305
480
304
348
548
341
392
616
377
444
698
418
517
815
469
585
927
514
671
1064
565
758
1227
623

1421
690

1638

1869

Aluminium conductor, rated current in A

114
112
177
116
113
136
135
212
138
136
162
158
252
164
159
199
196
310
201
197
238
234
372
240
236
272
268
425
272
269
305
300
476
303
302
347
342
541
340
342
404
398
631
387
397
457
457
716
430
454
525
529
825
479
520
601
609
952
531
584
687

1102
587

776

1267

865

1448

31
40
52
65
87
113
146
176
208
256
307
349
391
442
509
569
637
691

2)

Rated current in direct current systems with remote return conductor

Denition of load factor DIN VDE 0276 part 603.

Current carrying capacity in Ampere (A), laying in air (30C)

Insulation material
Permissible operating
temperature

VPE
90 C
N2XY

N2XCY

NA2XY

NA2XCY

1)

Nominal-Cross-section
in mm
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
1)

26
34
44
56
77
102
138
170
207
263
325
380
437
507
604
697
811
940
1083
1228
1368

Copper conductor, rated current in A


25
33
27
32
43
36
42
57
47
53
72
59
74
99
81
98
131
109
133
177
146
162
217
179
197
265
218
250
336
275
308
415
336
359
485
388
412
557
438
475
646
501
564
774
580
649
901
654
761
1060
733
866
1252
825

1486
934

1751

2039

25
33
43
54
75
100
136
165
201
255
314
364
416
480
565
643
737
807

Aluminium conductor, rated current in A

106
102
136
112
104
130
126
166
137
128
161
149
205
169
152
204
191
260
214
194
252
234
321
263
239
295
273
376
308
278
339
311
431
349
316
395
360
501
401
365
472
427
600
469
430
547
507
696
535
506
643
600
821
615
575
754
695
971
700
682
882

1151
790

1019

1355

1157

1580

Rated current in direct current systems with remote return conductor

X 32
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Current carrying capacity for NYKY 0,6/1 kV


The guidelines for current carrying capacities of copper and aluminium are valid DIN VDE 0265 and 0276
part 1000.
The current carrying capacity of a cable should be limited in such a degree that at all locations in a cable
system which causes the generated heats under given proportions to lead safely in the environment.
The heat ow depends on the inner heat-resistance between conductor and outer surface of the cable
and as well as from the heat emission to the surroundings.
For cables laid in earth, the assumption for the calculation are chosen in a way that the given values for
current loading at normal operation can be used in most of the cases without conversion.
For single cables laid directly in earth at EVU-Loading and a specic earth heat-resistance of 100 K cm/W,
mostly of the soil conditions are to be taken into consideration.

Calculation basis

Current loading for multicore cables


(5 cores and more)

EVU-load (current loading grade)

0,7 (1,0 for air)

Specic
earth heat-resistance

100 K cm/W

Specic heat-resistance of the


insulation and sheath

600 K cm/W

Bedding depth in earth

0,7 m

Earth temperature

20 C

Ambient temperature in the air

30 C

Current carrying capacity in ampere (A):

section
mm2
1,5
2,5
4
6

10
16
25
35
50
70
95
120
150
185
240
300
400

3- and 4-core cable


Earth
A
28
37
48
60

80
103
134
162
192
235
283
323
363
412
478
542
615

Air
A
18,5
27
36
45

62
81
110
134
163
205
253
294
334
386
457
529
610

5- to 61-core cable
Earth
A

The conversion factors according to the number of


loaded cores are to be multiplied with the loading
values of the above table.

Number of
loading
conductors

Current carrying capacity of 3-, 4- and multicore


(5 cores and more) cables at ambient temperature
of 20C in earth, 30C for the air.

cross-

The current loading of each core for cables with a


conductor cross-section of 1,5 to 10 mm2, depends
on the number of cores and the number of loaded
cores respectively and is calculated by means of the
following conversion factors.

Air
A

Number of loading
cores and the conver
sion factors from
1,5 to 10 mm2 see the
following table

Conversion factors for the value


to 1,5 to 10 mm2 of the above table
Earth

Air

0,70

0,75

0,60

0,65

10

0,50

0,55

14

0,45

0,50

19

0,40

0,45

24

0,35

0,40

40

0,30

0,35

61

0,25

0,30

Note
During the installation in earth or in the air, for the
operation and the laying performance occur any
deviations or unfavourable relations (e. g. bundling
of cables, in the wall, under plaster, on the wall or
on trays, on cable troughs or on cable racks), the
specied conversion factors to DIN VDE 0276 part
1000 table 12 and 13 must be taken into consideration.

X
X 33

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Current ratings Conversion factors


for grouping on the wall, on the oor, in insulation tubes or in conduit and
under the ceiling
Number of multicore cables or number
of a.c. or 3-phase circuits of single
core cables

10

12

14

16

18

20

Installation method

Conversion factors

One layer under the ceiling with contact

0,95 0,81 0,72 0,68 0,66 0,64 0,63 0,62 0,61 0,61 0,61 0,61 0,61 0,61 0,61

One layer under the ceiling, with a space


equal to the outer diameter d

0,95 0,85 0,85 0,85 0,85 0,85 0,85 0,85 0,85 0,85 0,85 0,85 0,85 0,85 0,85

One layer on the wall or on the oor


with a space equal to the
outer diameter d

1,00 0,94 0,90 0,90 0,90 0,90 0,90 0,90 0,90 0,90 0,90 0,90 0,90 0,90 0,90

One layer on the wall or on the


floor with contact

1,00 0,85 0,79 0,75 0,73 0,72 0,72 0,71 0,70 0,70 0,70 0,70 0,70 0,70 0,70

Bunched directly on the wall, on


the oor, in insulating tubes or
trunking or in the wall

1,00 0,80 0,70 0,65 0,60 0,57 0,54 0,52 0,50 0,48 0,45 0,43 0,41 0,39 0,38

 Symbol for one single core or one multicore cable

*Conversion factors for multicore cables ( 5 cores), Conductor


cross-section from 1,5 to 10 mm2
Conversion factors for the values of 1,5 to 10 mm2 to the
belonging table
Earth

Number of
loaded cores
5
7
10
14
19
24
40
61

0,7
0,6
0,5
0,45
0,4
0,35
0,3
0,25

Air
0,75
0,65
0,55
0,5
0,45
0,4
0,35
0,3

*For other conditions e.g. ground temperature, grouping, load factor, thermal resistance, the rating factors should be calculated according to DIN VDE 0276 part1000.
Notes:
when these factors are to be applied for the calculation of power ratings, the same type of cables and with equal loaded cores in the same installation method shall correspond.
At the same time the cross-section are permitted to differ maximum one grade of cross-section.
If the actual horizontal-space between the adjacent cables is more than double of the outer diameter, no reduction factor is necessary.
The same reduction factors are to be applied for grouping of two or three-core or multicore cables. For a system consisting of two or as well as three-core cables, rstly the
total number of cables will be assumed as the number of circuits. For that the applicable factor is to be used either in the tables for two-cores loaded cables or the tables for
three-cores loaded cables.
If the grouping of single core cables consist of n loaded single core cables, the rating factor shall be determinated for n/2 or n/3 circuits and applied to the current carrying
capacity of two or three loaded cores.

X 34
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Current ratings Conversion factors


for deviating ambient temperature
Conversion factors for
deviating ambient temperature
Permissible
40C
operating
temperature

60C

70C

Conversion temperature for


heat-resistant cables

80C

85C

90C

Permissible
operating
temperature

80C

90C

110C

135C

180C

Ambient
temperature C

Conversion factors,
used to the current ratings data for heat-resistant
cables in the tables of the following pages

Ambient
temperature C

Conversion factors,
used to the current ratings data in tables
of the following pages

10

1,73

1,29

1,22

1,18

1,17

1,15

bis 50

1,00

1,00

1,00

1,00

1,00

15

1,58

1,22

1,17

1,14

1,13

1,12

55

0,91

0,94

1,00

1,00

1,00

20

1,41

1,15

1,12

1,10

1,09

1,08

60

0,82

0,87

1,00

1,00

1,00

25

1,22

1,08

1,06

1,05

1,04

1,04

65

0,71

0,79

1,00

1,00

1,00

30

1,00

1,00

1,00

1,00

1,00

1,00

70

0,58

0,71

1,00

1,00

1,00

35

0,71

0,91

0,94

0,95

0,95

0,96

75

0,41

0,61

1,00

1,00

1,00

40

0,82

0,87

0,89

0,90

0,91

80

0,50

1,00

1,00

1,00

45

0,71

0,79

0,84

0,85

0,87

85

0,35

0,91

1,00

1,00

50

0,58

0,71

0,77

0,82

90

0,82

1,00

1,00

55

0,41

0,61

0,71

0,76

95

0,71

1,00

1,00

60

0,50

0,63

0,71

100

0,58

0,94

1,00

65

0,35

0,55

0,65

105

0,41

0,87

1,00

70

0,45

0,58

110

0,79

1,00

75

0,32

0,50

115

0,71

1,00

80

0,41

120

0,61

1,00

85

0,29

125

0,50

1,00

130

0,35

1,00

135

1,00

140

1,00

145

1,00

150

1,00

Conversion factors for


multicore cables with
cross-section up to 10 mm2
Number of
loaded cores

Conversion factors

0,75

155

0,91

0,65

160

0,82

10

0,55

165

0,71

14

0,50

170

0,58

19

0,45

175

0,41

24

0,40

40

0,35

61

0,30

Conversion factors for


reeled cables
Number of layers on drums

Conversion factors

0,80

0,61

0,49

0,42

0,38

Note: For spiral-reeling the conversion factor 0,80.

X
X 35
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Current ratings Conversion factors


for grouping of single core cables or cables on troughs and trays
Number of three-phase systems with
single core cables

Used as multiplier
for the ratings
value for

Number of
throughs or
trays

Three-cores cable in
horizontal-surface
arrangement

0,98

0,91

0,87

0,96

0,87

0,81

0,95

0,85

0,78

0,96

0,86

0,95

0,84

1,00

0,97

0,96

0,98

0,93

0,89

0,97

0,90

0,86

1,00

0,98

0,96

0,97

0,93

0,89

0,96

0,92

0,86

1,00

0,91

0,89

1,00

0,90

0,86

1,00

1,00

1,00

0,97

0,95

0,93

0,96

0,94

0,90

Conversion factors

Installation method
Perforated cable
troughs

with contact

with contact

Cable trays

with contact

Three-cores cable
vertical-surface
arrangement

Three-cores cable in
horizontal-surface
arrangement

Perforated cable
troughs

Three-core cables in
vertical-surface triangle
arrangement

Cable trays

Note:
The conversion factors are used only for cables of one layer grouping arrangement. These are not valied when the cables are installed with contact one upon another or the
given sprees between the cable toughs or cable trays are not followed. In such cases the conversion factors can be reduced.
To parallel current circuits each group of three conductors of the parallel circuit is regarded as single circuit.

X 36
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Current ratings Conversion factors


for grouping of multicore cables or cables on troughs and trays
Number of multicore cables
Installation method
Non-perforted
cable troughs

Perforated cable
troughs

with contact

with contact

with space

Number of troughs
and trays

Conversion factors

0,97

0,84

0,78

0,75

0,71

0,68

0,97

0,83

0,76

0,72

0,68

0,63

0,97

0,82

0,75

0,71

0,66

0,61

0,97

0,81

0,73

0,69

0,63

0,58

1,00

0,88

0,82

0,79

0,76

0,73

1,00

0,87

0,80

0,77

0,73

0,68

1,00

0,86

0,79

0,76

0,71

0,66

1,00

0,84

0,77

0,73

0,68

0,64

1,00

1,00

0,98

0,95

0,91

1,00

0,99

0,96

0,92

0,87

1,00

0,98

0,95

0,91

0,85

1,00

0,88

0,82

0,78

0,73

0,72

1,00

0,88

0,81

0,76

0,71

0,70

1,00

0,91

0,89

0,88

0,87

1,00

0,91

0,88

0,87

0,85

1,00

0,87

0,82

0,80

0,79

0,78

1,00

0,86

0,81

0,78

0,76

0,73

1,00

0,85

0,79

0,76

0,73

0,70

1,00

0,83

0,76

0,73

0,69

0,66

1,00

1,00

1,00

1,00

1,00

1,00

0,99

0,98

0,97

0,96

1,00

0,98

0,97

0,96

0,93

with contact

with space

Cable trays

with contact

with space

Note:
The conversion factor are used for cables of one layer grouping arrangement. These are not valid when the cables are installed with contact one upon another or the given spaces
between the cable troughs or cable trays can not meet. In such cases the conversion factor can be reduced.

X 37
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Power ratings for XLPE-insulated Medium


Voltage Power Cables single core 6/10 kV, 12/20 kV, 18/30 kV
N2XSY
NA2XSY

N2XS2Y
NA2XS2Y

N2XS(F)2Y
NA2XS(F)2Y

Current carrying capacity* in Amperes (A) in ground (20C)


Conductor material Copper conductor

Aluminium conductor

Arrangement
U0/U

6/10 kV

12/20 kV

cross section mm2


25
35
50
70
95
120
150
185
240
300
400
500

18/30 kV

6/10 kV

12/20 kV

18/30 kV

Current ratings in Ampere (A)


157
187
220
268
320
363
405
456
526
591
662
744

179
212
249
302
359
405
442
493
563
626
675
748

189
222
271
323
367
409
461
532
599
671
754

213
250
303
360
407
445
498
568
633
685
760

225
274
327
371
414
466
539
606
680
765

251
304
362
409
449
502
574
640
695
773

145
171
208
248
283
315
357
413
466
529
602

165
194
236
281
318
350
394
452
506
558
627

172
210
251
285
319
361
417
471
535
609

195
237
282
319
352
396
455
510
564
634

174
213
254
289
322
364
422
476
541
616

195
238
283
321
354
399
458
514
570
642

*This factors are also valid for longitudinally water-tight cable

Current carrying capacity* in Amperes (A) in air (30C)


Conductor material Copper conductor

Aluminium conductor

Arrangement
U0/U

6/10 kV

cross section mm
25
35
50
70
95
120
150
185
240
300
400
500

12/20 kV

18/30 kV

6/10 kV

12/20 kV

18/30 kV

Current ratings in Ampere (A)


163
197
236
294
358
413
468
535
631
722
827
949

194
235
282
350
426
491
549
625
731
831
920
1043

200
239
297
361
416
470
538
634
724
829
953

235
282
351
426
491
549
625
731
830
923
1045

241
299
363
418
472
539
635
725
831
953

282
350
425
488
548
624
728
828
922
1045

153
183
228
278
321
364
418
494
568
660
767

182
219
273
333
384
432
496
583
666
755
868

185
231
280
323
366
420
496
569
660
766

219
273
332
384
432
494
581
663
753
866

187
232
282
325
367
421
496
568
650
764

219
273
331
382
429
492
578
659
750
861

*This factors are also valid for longitudinally water-tight cable

X 38
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Electrical characteristics of XLPE-insulated


Medium Voltage Power Cables, 6 30 kV
Conductor resistance 20C
maximum value
cross-section
mm2

Cu-conductor
Ohm/km

Alu-conductor
Ohm/km

25
35

0,727
0,524

1,20
0,868

50
70
95
120

0,387
0,268
0,193
0,153

0,641
0,443
0,320
0,253

150
185
240
300

0,124
0,0991
0,0754
0,0601

0,206
0,164
0,125
0,100

400
500

0,0470
0,0366

0,0778
0,0605

Conversion factors for the conductor temperatures


Temperature at C

60

65

70

80

90

Cu-conductor

1,157

1,177

1,196

1,236

1,275

Alu-conductor

1,161

1,181

1,202

1,242

1,282

Conversion formula:
R = R20

234,5 + 
254,5

for Cu-conductor

R = R20

228 + 
248

for Alu-conductor

Conductor temperature at C
=
Conductor resistance at  C in Ohm/km = R
Conductor resistance at 20 C in Ohm/km = R20

X
X 39
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Electrical characteristics of XLPE-insulated


Medium Voltage Power Cables, 6 30 kV
Effective resistance at 50 Hz (Alternating-current resistance)
Copper conductor
Nominal voltage

6/10 kV

12/20 kV

Cross-section

18/30 kV

approx Ohm/km

mm2
35
50
70
95
120
150
185
240
300
400
500

0,671
0,497
0,345
0,249
0,198
0,163
0,132
0,102
0,082
0,068
0,055

0,673
0,498
0,346
0,251
0,200
0,165
0,134
0,104
0,085
0,071
0,058

0,671
0,496
0,345
0,249
0,198
0,163
0,131
0,101
0,082
0,067
0,055

0,672
0,498
0,346
0,250
0,200
0,165
0,133
0,103
0,084
0,070
0,058

0,496
0,344
0,249
0,198
0,162
0,131
0,101
0,082
0,067
0,054

0,497
0,346
0,250
0,199
0,164
0,133
0,103
0,084
0,069
0,057

Aluminium conductor
Nominal voltage

6/10 kV

12/20 kV

Cross-section

18/30 kV

approx Ohm/km

mm2
35
50
70
95
120
150
185
240
300
400
500

1,12
0,825
0,571
0,413
0,327
0,269
0,215
0,165
0,133
0,106
0,085

1,12
0,826
0,572
0,415
0,329
0,271
0,217
0,167
0,135
0,109
0,088

1,12
0,825
0,571
0,413
0,327
0,268
0,215
0,165
0,133
0,106
0,084

1,12
0,826
0,572
0,414
0,329
0,270
0,217
0,167
0,135
0,109
0,087

0,824
0,571
0,413
0,327
0,268
0,214
0,164
0,133
0,106
0,084

0,826
0,572
0,414
0,328
0,270
0,216
0,166
0,135
0,108
0,087

Inductive resistance at 50 Hz
Nominal voltage

6/10 kV

12/20 kV

Cross-section

18/30 kV

Ohm/km

mm2
35
50
70
95
120
150
185
240
300
400
500

0,144
0,136
0,129
0,123
0,118
0,114
0,110
0,105
0,102
0,097
0,094

0,158
0,150
0,143
0,137
0,132
0,128
0,124
0,120
0,116
0,111
0,108

0,153
0,145
0,138
0,131
0,126
0,121
0,117
0,112
0,108
0,103
0,100

0,168
0,159
0,152
0,145
0,140
0,135
0,131
0,126
0,123
0,117
0,114

0,154
0,147
0,139
0,134
0,129
0,125
0,120
0,115
0,110
0,106

0,169
0,161
0,154
0,148
0,143
0,139
0,134
0,130
0,124
0,120

X 40
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Electrical characteristics of XLPE-insulated


Medium Voltage Power Cables, 6 30 kV
Mutual capacitance
Nominal voltage

6/10 kV

12/20 kV

18/30 kV

mm2

F/km

F/km

F/km

35
50
70
95
120
150
185
240
300
400
500

0,22
0,25
0,28
0,31
0,34
0,37
0,40
0,44
0,48
0,55
0,60

0,16
0,18
0,20
0,22
0,23
0,25
0,27
0,30
0,32
0,36
0,40

0,14
0,15
0,17
0,18
0,19
0,20
0,22
0,24
0,27
0,29

Cross-section

Inductance
Nominal voltage
Cross-section
mm2
35
50
70
95
120
150
185
240
300
400
500

6/10 kV

12/20 kV

mH/km

mH/km

0,45
0,42
0,39
0,38
0,36
0,35
0,34
0,32
0,31
0,30
0,29

0,76
0,73
0,70
0,67
0,65
0,63
0,61
0,59
0,57
0,55
0,53

mH/km
0,48
0,45
0,43
0,41
0,39
0,38
0,36
0,35
0,33
0,33
0,31

18/30 kV

mH/km
0,76
0,74
0,70
0,68
0,65
0,63
0,62
0,59
0,58
0,55
0,53

mH/km

0,48
0,45
0,43
0,42
0,41
0,39
0,37
0,36
0,34
0,33

mH/km

0,75
0,71
0,68
0,66
0,64
0,63
0,60
0,59
0,56
0,54

X
X 41
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Electrical characteristics of XLPE-insulated


Medium Voltage Power Cables, 6 30 kV
Short-circuit current carrying capacity up to 30 kV
Conductor temperature: 90 C
Short-circuit temperature: 250 C
Cable with Cu-conductors
cross-

short-circuit time in s (seconds)

section
0,1

0,2

0,3

0,4

0,5

mm

0,6

0,7

0,8

0,9

1,0

1,5

2,0

3,0

4,0

5,0

permissible short-circuit in kA

25

11,3

8,0

6,5

5,7

5,1

4,6

4,3

4,0

3,8

3,6

2,9

2,5

2,1

1,8

1,6

35

15,8

11,2

9,1

7,9

7,1

6,5

6,0

5,6

5,3

5,0

4,1

3,5

2,9

2,5

2,2

50

22,6

16,0

13,1

11,3

10,1

9,2

8,5

8,0

7,5

7,2

5,8

5,1

4,1

3,6

3,2

70

31,7

22,4

18,3

15,8

14,2

12,9

12,0

11,2

10,6

10,0

8,2

7,1

5,8

5,0

4,5

95

43,0

30,4

24,8

21,5

19,2

17,5

16,2

15,2

14,3

13,6

11,1

9,6

7,8

6,8

6,1

120

54,3

38,4

31,3

27,1

24,3

22,2

20,5

19,2

18,1

17,2

14,0

12,1

9,9

8,6

7,7

150

67,8

48,0

39,2

33,9

30,3

27,7

25,6

24,0

22,6

21,5

17,5

15,2

12,4

10,7

9,6

185

83,7

59,2

48,3

41,8

37,4

34,2

31,6

29,6

27,9

26,5

21,6

18,7

15,3

13,2

11,8

240

108,5

76,7

62,7

54,3

48,5

44,3

41,0

38,4

36,2

34,3

28,0

24,3

19,8

17,2

15,3

300

135,7

95,9

78,3

67,8

60,7

55,4

51,3

48,0

45,2

42,9

35,0

30,3

24,8

21,5

19,2

400

180,9

127,9

104,4

90,4

80,9

73,8

68,4

64,0

60,3

57,2

46,7

40,4

33,0

28,6

25,6

500

226,1

159,9

130,5

113,1

101,1

92,3

85,5

79,9

75,4

71,5

58,4

50,6

41,3

35,8

32,0

1,0

1,5

2,0

3,0

4,0

5,0

Cable with Alu-conductors


cross-

short-circuit time in s (seconds)

section
0,1

0,2

0,3

0,4

0,5

mm

0,6

0,7

0,8

0,9

permissible short-circuit in kA

25

7,4

5,3

4,3

3,7

3,3

3,0

2,8

2,6

2,5

2,4

1,9

1,7

1,4

1,2

1,1

35

10,4

7,4

6,0

5,2

4,7

4,2

3,9

3,7

3,5

3,3

2,7

2,3

1,9

1,6

1,5

50

14,9

10,5

8,6

7,4

6,6

6,1

5,6

5,3

5,0

4,7

3,8

3,3

2,7

2,4

2,1

70

20,8

14,7

12,0

10,4

9,3

8,5

7,9

7,4

6,9

6,6

5,4

4,7

3,8

3,3

2,9

95

28,2

20,0

16,3

14,1

12,6

11,5

10,7

10,0

9,4

8,9

7,3

6,3

5,2

4,5

4,0

120

35,7

25,2

20,6

17,8

16,0

14,6

13,5

12,6

11,9

11,3

9,2

8,0

6,5

5,6

5,0

150

44,6

31,5

25,7

22,3

19,9

18,2

16,9

15,8

14,9

14,1

11,5

10,0

8,1

7,1

6,3

185

55,0

38,9

31,7

27,5

24,6

22,5

20,8

19,4

18,3

17,4

14,2

12,3

10,0

8,7

7,8

240

71,3

50,4

41,2

35,7

31,9

29,1

27,0

25,2

23,8

22,6

18,4

16,0

13,0

11,3

10,1

300

89,2

63,1

51,5

44,6

39,9

36,4

33,7

31,5

29,7

28,2

23,0

19,9

16,3

14,1

12,6

400

118,9

84,1

68,6

59,5

53,2

48,5

44,9

42,0

39,6

37,6

30,7

26,6

21,7

18,8

16,8

500

148,6

105,1

85,8

74,3

66,5

60,7

56,2

52,5

49,5

47,0

38,4

33,2

27,1

23,5

21,0

X 42
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Electrical characteristics of XLPE-insulated


Medium Voltage Power Cables, 6 30 kV
Short-circuit to ground
Nominal voltage

6/10 kV

12/20 kV

18/30 kV

cross-section
mm2

A/km

A/km

A/km

35

1,2

1,7

50

1,4

1,9

2,3

70

1,5

2,1

2,5

95

1,7

2,4

2,7

120

1,9

2,6

2,9

150

2,0

2,7

3,1

185

2,2

3,0

3,3

240

2,4

3,3

3,7

300

2,6

3,5

4,0

400

3,0

4,0

4,4

500

3,3

4,3

4,8

Short-circuit current carrying capacity of copper screens Short-circuit temperature: 350C


short-circuit time
in seconds

load of short-circuit current in kA


2

up to 16 mm

25 mm2

35 mm2

kA

kA

kA

0,1

9,7

15,1

21,2

0,2

6,9

10,7

15,1

0,3

5,7

8,9

12,5

0,4

5,0

7,7

10,9

0,5

4,5

7,0

9,8

0,6

4,2

6,4

9,0

0,7

3,9

6,0

8,4

0,8

3,5

5,6

7,9

0,9

3,4

5,3

7,5

1,0

3,3

5,1

7,2

1,5

2,7

4,2

5,9

2,0

2,3

3,6

5,1

3,0

1,9

2,9

4,2

4,0

1,7

2,6

3,6

5,0

1,5

2,3

3,2

Coordination of screen-cross-section
conductor cross-section
mm2

screen-cross-section
mm2

35 to 120

16

150 to 300

25

400 and 500

35

X
X 43

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Rating conversion factors for installation of


Medium Voltage Cables, 6 30 kV
Rating conversion factors for laying in air*)
Single core cables in 3-phase systems
Arrangement
of cables
in laying
condition

Number For laying on plain surface


of cables Space = cable d
troughs
Distance from wall  2 cm
or trays
Number of systems
on top of
each other
Installation method
1
2
3

For installation in grouping


Space = 2 x cable d
Distance from wall  2 cm
Number of systems
Installation method

on the
ground

on nonperforated
cable
troughs
(restricted
air circulation)

on
perforated
cable
troughs

on cable
trays or
on cable
ladders
(unrestricted air
circulation)

on
platform
or
on the wall

0,92

0,89

0,88

0,98

0,96

0,94

0,92

0,89

0,88

0,98

0,96

0,94

0,87

0,84

0,83

0,95

0,91

0,87

0,84

0,82

0,81

0,94

0,90

0,85

0,82

0,80

0,79

0,93

0,88

0,82

1,00

0,93

0,90

1,00

0,98

0,96

0,97

0,89

0,85

0,97

0,93

0,89

0,96

0,88

0,82

0,96

0,92

0,85

0,94

0,84

0,80

0,95

0,90

0,83

1,00

0,97

0,96

1,00

1,00

1,00

0,97

0,94

0,93

0,97

0,95

0,93

0,96

0,93

0,92

0,96

0,94

0,90

0,94

0,91

0,90

0,95

0,93

0,87

0,94

0,91

0,89

1,00

0,91

0,89

0,94

0,90

0,86

1,00

0,90

0,86

Arrangements,
for which a
reduction not
necessary1)

For the installation on plain surface with greater


distance, the muntual heating is lower, for this
occur the additional sheath or screen-losses.
Because of that no particulars can be made for
reduction-free arrangements.
.

*Conversion factors for deviating ambient temperature


Temperature C

10

15

20

25

30

35

40

45

50

VPE-cable

1,15

1,12

1,08

1,04

1,0

0,96

0,91

0,87

0,82

PVC-cable

1,22

1,17

1,12

1,06

1,0

0,94

0,87

0,79

0,71

1)

In narrow rooms or for bigger grouping, the air temperature is increased due to energy losses of cable, so the additional conversion factors for deviating air-temperatures are to
be taken in the given table.

X 44
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Rating conversion factors for installation of


Medium Voltage Cables 6 30 kV
Rating conversion factors for laying in air*)
Multicore cable and single core direct current cable
Arrangement
of cables
in laying
condition

Number
of cables
troughs
or trays

Without inter-contact
Space = cable d
Distance from wall  2cm

With inter-contact
contact with wall

Number of cables
Installation method

Number of cables
6

Installation method

on the
ground

on nonperforated
cable
troughs
(restricted
air
circulation)
on
perforated
cable
troughs

on
cable trays
or
on cable
ladders
(unrestricted
air
circulation)

0,97 0,96 0,94 0,93 0,90

0,97 0,85 0,78 0,75 0,71 0,68

0,97 0,96 0,94 0,93 0,90

0,97 0,85 0,78 0,75 0,71 0,68

0,97 0,95 0,92 0,90 0,86

0,97 0,84 0,76 0,73 0,68 0,63

0,97 0,94 0,91 0,89 0,84

0,97 0,83 0,75 0,72 0,66 0,61

0,97 0,93 0,90 0,88 0,83

0,97 0,81 0,73 0,69 0,63 0,58

1,00 1,00 0,98 0,95 0,91

1,00 0,88 0,82 0,79 0,76 0,73

1,00 0,99 0,96 0,92 0,87

1,00 0,87 0,80 0,77 0,73 0,68

1,00 0,98 0,95 0,91 0,85

1,00 0,86 0,79 0,76 0,71 0,66

1,00 0,97 0,94 0,90 0,84

1,00 0,84 0,77 0,73 0,68 0,64

1,00 1,00 1,00 1,00 1,00

1,00 0,87 0,82 0,80 0,79 0,78

1,00 0,99 0,98 0,97 0,96

1,00 0,86 0,80 0,78 0,76 0,73

1,00 0,94 0,97 0,96 0,93

1,00 0,85 0,79 0,76 0,73 0,70

1,00 0,97 0,96 0,94 0,91

1,00 0,83 0,76 0,73 0,69 0,66

1,00 0,91 0,89 0,88 0,87

1,00 0,88 0,82 0,78 0,73 0,72

1,00 0,91 0,88 0,87 0,85

1,00 0,88 0,81 0,76 0,71 0,70

0,95 0,78 0,73 0,72 0,68 0,66

on platform
or
1
on wall
or
on perfo2
rated cabletray
laid on
platform
or
on the wall

Arrangements,
for which a
reduction not
necessary1)

Number of cable
arranged one over
another is optional

Number of cable
arranged sideby-side is optional

Note
Conversion factors for deviating ambient temperature see page X 40

1)
In narrow rooms or for bigger grouping, the air temperature is increased due to energy losses of cable, so the additional conversion factors for deviating
air temperatures are to be taken in the given table.

X
X 45

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Conversion factor for


Medium Voltage Power Cables, 6 30 kV
Load rating for cables laid in ground
Load factor 0,7 and 1,0
Fundamental conditions*
Ground temperature
20 C
Thermal resistivity
1,0 K m/W
Distance between cables or systems
7 cm
Single core cables laid in trefoil touching arrangement
Load factor 0,7
Type of
insulation

Cable
design

PVC

VPE

Nominal
voltage

Multicore cables
Three-core cables
Single core cables
Single core cables

0,6/1

Multicore cables
Three-core cables

0,6/1
0,6/1

0,6/1

to
to
to
to

Number of cables or systems


4
6
8
10

3,6/6 kV
6/10 kV
3,6/6 kV
6/10 kV

0,86
0,87
0,85
0,83

0,71
0,71
0,70
0,66

0,64
0,63
0,63
0,57

0,60
0,59
0,59
0,53

0,57
0,54
0,56
0,49

to 18/30 kV
to 18/30 kV

0,85
0,85

0,70
0,70

0,63
0,63

0,59
0,58

0,56
0,56

Load factor 1,0


Type of
insulation
PVC

VPE

Cable
design

Nominal
voltage

Multicore cables
Three-core cables
Single core cables
Single core cables

0,6/1

Multicore cables
Single core cables

0,6/1
0,6/1

0,6/1

Number of cables or systems


2
4
6
8

10

to
to
to
to

3,6/6 kV
6/10 kV
3,6/6 kV
6/10 kV

0,81
0,82
0,79
0,78

0,66
0,67
0,65
0,62

0,52
0,51
0,51
0,47

0,46
0,45
0,46
0,40

0,43
0,41
0,42
0,36

0,40
0,37
0,40
0,33

to
to

18/30 kV
18/30 kV

0,83
0,81

0,67
0,66

0,53
0,52

0,47
0,47

0,44
0,43

0,41
0,41

Build-up of systems:

for single core cables

for multicore cables

X 46
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Colour code according to DIN VDE 02931) (old)


Multicore exible cables
Number
of cores

Cores with
green-yellow protective conductor

brown/blue

green-yellow/brown/blue

black/blue/brown

green-yellow/black/blue/brown

black/blue/brown/black

green-yellow/black/blue/brown/black

black/blue/brown/black/black

6 and more

green-yellow/others black with white numbering black with white numbering

(J)

Cores without
green-yellow protective conductor (O)

Multicore cables for xed installation


Number
of cores

Cores with
green-yellow protective conductor

Cores without
green-yellow protective conductor (O)

with protective
conductor

green-yellow/black*

black/blue

black/blue

green-yellow/black/blue

black/blue/brown

black/blue/brown

green-yellow/black/blue/brown

black/blue/brown/black

black/blue/brown/black

green-yellow/black/blue/brown/black

black/blue/brown/black/black

6 and more

green-yellow/others black with white numbering black with white numbering

(J)

black with white numbering

* This type is according to DIN VDE 0100 part 540, table 2 valid only for copper cross-section of 10 mm2 and more or Alu 16 mm2.

Colour code according to DIN VDE 0293-3082) (new)


Number
of cores

Cores with
green-yellow protective conductor

brown/blue

green-yellow/brown/blue

brown/black/grey

33)

blue/brown/black

green-yellow/brown/black/grey

blue/brown/black/grey

43)

green-yellow/blue/brown/black

green-yellow/blue/brown/black/grey

blue/brown/black/grey/black

6 and more

green-yellow/others black with white numbering black with white numbering

(J)

Cores without
green-yellow protective conductor

(O)

1)

Coding in accordance with VDE 0293: 1990-01 / transitional periods until 1 April 2006, beyond that only the coding for 6 or more
conductors will continue to exist.
2)
Coding in accordance with VDE 0293-308 (valid as of 1 January 2003).
3)
Only for certain applications.

Core marking with numbering (in direction to longitudinal axis)


Height and gap of numbers
Core-nominal-
mm

e*)
mm

h
mm

i
mm

d
mm

D ) 2,4

* 0,6

* 2,3

ca. 2

) 50

2,4 < D ) 5,0

* 1,2

* 3,2

ca. 3

) 50

5,0 < D

* 1,6

* 4,6

ca. 4

) 50

e:
h:
i:
d:

breadth of number
height of number
gap between two successive numbers and between number and dash
gap between two successive numbers

*) when the number in only 1, the smallest breadth is half of the


given dimension to this column.

X
X 47

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Colour code according to E DIN VDE 0245 part 1


Application for types:

NLSY
NLSCY

NSY
NSYCY

According to DIN-Norm 0245 series, the core identication is stated whether the code is to be marked with
colours or with numberings.
Identication with colours
The core colour is given in basic colour and ring colour. For the identication of two or three colours, the
rst underlined colour is the basic colour.
The identication of the basic colours must be followed through colouring of the insulation or the
oversurface of insulation cores.
The second and the third colour is printed over the basic colour as a form of ring.
Counting
The cores are to be counted continuously through all layers at the same direction, beginning with core 1 in
inner layer towards outside. Measures of rings and distances are given in mm.
coloured

without printing

basic colour + ring colour


to

basic colour + ring colour


to

Core
No.

Basic- and
ring colour

Core
No.

Basic- and
ring colour

Core
No.

Basic- and
ring colour

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

white
brown
green
yellow
grey
pink
blue
red
black
violet
greypink
redblue
whitegreen
browngreen
whiteyellow
yellowbrown
whitegrey
greybrown
whitepink
pinkbrown
whiteblue

22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42

brownblue
whitered
brownred
whiteblack
brownblack
greygreen
yellowgrey
pinkgreen
yellowpink
greenblue
yellowblue
greenred
yellowred
greenblack
yellowblack
greyblue
pinkblue
greyred
pinkred
greyblack
pinkblack

43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60

blueblack
redblack
whitebrownblack
yellowgreenblack
greypinkblack
redblueblack
whitegreenblack
browngreenblack
whiteyellowblack
yellowbrownblack
whitegreyblack
greybrownblack
whitepinkblack
pinkbrownblack
whiteblueblack
brownblueblack
whiteredblack
brownredblack

Example: Core 21 whiteblue


basic colour

ring colour

The given colours are corresponded to DIN IEC 60304 and HD 402.S2.
Identication through numberings as per DIN VDE 0293.
X 48
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Colour code according to DIN 47100


with colour repetition from core no. 45 and above
Electronic control and computer cable: single cores stranding
The insulation of the conductor gives the rst basic colour. The codes of the multi-coloured identication
are combined with a basic colour and colour rings. The second and third colour is printed on the basic
colour as a form of ring.
The ring width is 23 mm. A less unsharpness on the edge of the identication colour and a minor pledging
of both half-rings are permitted.
The cores are to be counted continuously through all layers at the same direction, beginning with the outer
layer towards inside.
No. Basic-Ring-colours

No. Basic-Ring-colours

No. Basic-Ring-colours

No. Basic-Ring-colours

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

33
34
35
36
37
38
39
40
41
42
43
44

45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61

white
brown
green
yellow
grey
pink
blue
red
black
violet
grey-pink
red-blue
white-green
brown-green
white-yellow
yellow-brown

white-grey
grey-brown
white-pink
pink-brown
white-blue
brown-blue
white-red
brown-red
white-black
brown-black
grey-green
yellow-grey
pink-green
yellow-pink
green-blue
yellow-blue

green-red
yellow-red
green-black
yellow-black
grey-blue
pink-blue
grey-red
pink-red
grey-black
pink-black
blue-black
red-black

white
brown
green
yellow
grey
pink
blue
red
black
violet
grey-pink
red-blue
white-green
brown-green
white-yellow
yellow-brown
white-grey

Colour code adapted* to DIN 47100


without colour repetition
No. Basic-Ring-colours

No. Basic-Ring-colours

No. Basic-Ring-colours

No. Basic-Ring-colours

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

33
34
35
36
37
38
39
40
41
42
43
44

45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61

white
brown
green
yellow
grey
pink
blue
red
black
violet
grey-pink
red-blue
white-green
brown-green
white-yellow
yellow-brown

white-grey
grey-brown
white-pink
pink-brown
white-blue
brown-blue
white-red
brown-red
white-black
brown-black
grey-green
yellow-grey
pink-green
yellow-pink
green-blue
yellow-blue

green-red
yellow-red
green-black
yellow-black
grey-blue
pink-blue
grey-red
pink-red
grey-black
pink-black
blue-black
red-black

white-brown-black
yellow-green-black
grey-pink-black
red-blue-black
white-green-black
brown-green-black
white-yellow-black
yellow-brown-black
white-grey-black
grey-brown-black
white-pink-black
pink-brown-black
white-blue-black
brown-blue-black
white-red-black
brown-red-black
black-white

* deviation to DIN, without colour repetition, from core no. 45 and above

X 49
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pair-Colour code according to DIN 47100


with colour repetition
Electronic control and computer cable: pair stranding
The insulation of the conductor gives the rst basic colour. The codes of the multi-coloured identication
are combined with a basic colour and colour rings. The second colour is printed on the basic colour as a
form of ring.
The ring width is 23 mm. A less unsharpness on the edge of the identication colour and a minor pledging
of both half-rings are permitted.
The cores are to be counted continuously through all layers at the same direction, beginning with the outer
layer towards inside.
Pair-stranding
Pair-no.

a
1

23

45

24

46

25

47

26

48

27

49

28

50

29

51

30

52

31

53

10

32

54

11

33

Pair-no.

55

brown

green

yellow

grey

pink

blue

red

black

violet

grey-pink

red-blue

white-green

brown-green

white-yellow

yellow-brown

white-grey

grey-brown

white-pink

pink-brown

white-blue

brown-blue

YV-Equipment wires
(for twin colour cables, the base colour is underlined)
white
green
grey
blue
black
white-brown
white-yellow
white-red
brown-green
brown-blue
green-yellow
green-black
yellow-red
grey-red
pink-black
blue-red
violet-red

br
ge
rs
rt
vi
wsgn
wsbl
wssw
brge
brsw
gnrt
gebl
gesw
grsw
rsvi
rtsw

brown
yellow
pink
red
violet
white-green
white-blue
white-black
brown-yellow
brown-black
green-red
yellow-blue
yellow-black
grey-black
pink-violet
red-black

12

34

56

13

35

57

14

36

58

15

37

59

16

38

60

17

39

61

18

40

62

19

41

63

20

42

64

21

43

65

22

44

colour
core

white

Colour code as per DIN 47002

ws
gn
gr
bl
sw
wsbr
wsge
wsrt
brgn
brbl
gnge
gnsw
gert
grrt
rssw
blrt
virt

Pair-stranding

colour
core

66

white-red

brown-red

white-black

brown-black

grey-green

yellow-grey

pink-green

yellow-pink

green-blue

yellow-blue

green-red

yellow-red

green-black

yellow-black

grey-blue

pink-blue

grey-red

pink-red

grey-black

pink-black

blue-black

red-black

Colour code for YR-Bell Sheathed Cables


2 x 0,8:
3 x 0,8:
4 x 0,8:
5 x 0,8:
6 x 0,8:
8 x 0,8:
10 x 0,8:
12 x 0,8:
14 x 0,8:
16 x 0,8:

bk, bu
bk, bu, bn
bk, bu, bn, ye
bk, bu, bn, ye, gn
bk, bu, bn, ye, gn, vt
bk, bu, bn, ye, gn, vt, wh, og
bk, bu, bn, ye, gn, vt, wh, og, tr, gy
bk, bu, bn, ye, gn, vt, wh, og, tr, gy, rd, lbu
bk, bu, bn, ye, gn, vt, wh, og, tr, gy, rd, lbu, cog, lgn
bk, bu, bn, ye, gn, vt, wh, og, tr, gy, rd, lbu, cog, lgn,
lrd, lye

X 50
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Colour code according to


international standard
Electronic control UL-version: single cores stranding
The insulation of the conductor gives the rst basic colour. The codes of the multi-coloured identication
are combined with a basic colour and colour rings. The second colour is printed on the basic colour as a
form of ring.
The ring width is 23 mm. A less unsharpness on the edge of the identication colour and a minor pledging
of both half-rings are permitted.
The cores are to be counted continuously through all layers at the same direction, beginning with the inside
layer towards outer.
No. Basic-Ring-colours

No. Basic-Ring-colours

No. Basic-Ring-colours

No. Basic-Ring-colours

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

31
32
33
34
35
36
37
38
39
40
41
42
43
44
45

46
47
48
49
50
51
52
53
54
55
56
57
58
59
60

black
brown
red
orange
yellow
green
blue
violet
grey
white
white-black
white-brown
white-red
white-orange
white-yellow

white-green
white-blue
white-violet
white-grey
brown-black
brown-red
brown-orange
brown-yellow
brown-green
brown-blue
brown-violet
brown-grey
brown-white
green-black
green-brown

green-red
green-orange
green-blue
green-violet
green-grey
green-white
yellow-black
yellow-brown
yellow-red
yellow-orange
yellow-blue
yellow-violet
yellow-grey
yellow-white
grey-black

grey-brown
grey-red
grey-orange
grey-yellow
grey-green
grey-blue
grey-violet
grey-white
orange-black
orange-brown
orange-red
orange-yellow
orange-green
orange-blue
orange-violet

Pair-colour code according to


international standard
Electronic control UL-version: pair stranding
The insulation of the conductor gives the rst basic colour. The codes of the multi-coloured identication
are combined with a basic colour and colour rings. The second colour is printed on the basic colour as a
form of ring.
The ring width is 23 mm. A less unsharpness on the edge of the identication colour and a minor pledging
of both half-rings are permitted.
The cores are to be counted continuously through all layers at the same direction, beginning with the inside
layer towards outer.
Pair-stranding
Pair-no.

Pair-stranding
co

Pair-no.

10

3
4
5
6
7
8

b
a
b
a
b
a
b

k
ange
black
yellow
black
green
black
blue
black
violet
black
grey

11
12
13
14
15
16

Pair-stranding
core

colour

a
b
a
b
a
b
a
b
a
b
a
b
a
b
a
b

black
white
brown
red
brown
orange
brown
yellow
brown
green
brown
blue
brown
violet
brown
grey

Pair-no.
17
18
19
20
21
22
23
24

core

colour

a
b
a
b
a
b
a
b
a
b
a
b
a
b
a
b

brown
white
red
orange
red
yellowz
red
green
red
blue
red
violet
red
grey
red
white

X
X 51
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Colour codes according to


international standards
TRAYCONTROL 300 / TRAYCONTROL 300-C (AWG 28-22)
No.

Basic-ring-colour

No.

Basic-ring-colour

No.

Basic-ring-colour

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

black
brown
red
orange
yellow
green
blue
violet
grey
white
white/black
white/brown
white/red
white/orange
white/yellow
white/green
white/blue

18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34

white/violet
white/grey
white/black/brown
white/black/red
white/black/orange
white/black/yellow
white/black/green
white/black/blue
white/black/violet
white/black/grey
white/brown/red
white/brown/orange
white/brown/yellow
white/brown/green
white/brown/blue
white/brown/violet
white/brown/grey

35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50

white/red/orange
white/red/yellow
white/red/green
white/red/blue
white/red/violet
white/red/grey
white/orange/yellow
white/orange/green
white/orange/blue
white/orange/violet
white/orange/grey
white/yellow/green
white/yellow/blue
white/yellow/violet
white/yellow/grey
white/green/blue

TRAYCONTROL 300 / TRAYCONTROL 300-C (AWG 20-16)


No.

Basic-ring-colour

No.

Basic-ring-colour

No.

Basic-ring-colour

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

black
red
white
green
orange
blue
brown
yellow
violet
grey
pink
hellbrown
red/green
red/yellow
red/black
white/black
white/red

18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34

white/green
white/yellow
white/blue
white/brown
white/orange
white/grey
white/violet
white/black/red
white/black/green
white/black/yellow
white/black/blue
white/black/brown
white/black/orange
white/black/grey
white/black/violet
white/black/black
white/red/black

35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50

white/red/red
white/red/green
white/red/blue
white/red/brown
white/red/violet
white/green/black
white/green/red
white/green/green
white/green/blue
white/green/brown
white/green/violet
white/blue/black
white/blue/red
white/blue/green
white/blue/blue
white/blue/brown

X 52
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Pair-colour codes according to


international standards
TRAYCONTROL 300 TP / TRAYCONTROL 300 TP-C (AWG 26-22)
Pair-stranding
Pair-no.
core
1
2
3
4
5
6
7
8
9

a
b
a
b
a
b
a
b
a
b
a
b
a
b
a
b
a
b

colour
black
red
black
white
black
green
black
blue
black
brown
black
yellow
black
orange
red
green
red
white

Pair-stranding
Pair-no.
core
10
11
12
13
14
15
16
17
18

a
b
a
b
a
b
a
b
a
b
a
b
a
b
a
b
a
b

colour
red
blue
red
yellow
red
brown
red
orange
green
blue
green
white
green
brown
green
orange
green
yellow

Pair-stranding
Pair-no.
core
19
20
21
22
23
24
25

a
b
a
b
a
b
a
b
a
b
a
b
a
b

colour
white
blue
white
brown
white
orange
white
yellow
blue
brown
blue
orange
blue
yellow

TRAYCONTROL 300 TP / TRAYCONTROL 300 TP-C (AWG 20-18)


Pair-stranding
Pair-no.
core
1
2
3
4
5
6
7
8
9

a
b
a
b
a
b
a
b
a
b
a
b
a
b
a
b
a
b

colour
white
black
white
brown
white
red
white
orange
white
yellow
white
green
white
blue
white
violet
white
grey

Pair-stranding
Pair-no.
core
10
11
12
13
14
15
16
17
18

a
b
a
b
a
b
a
b
a
b
a
b
a
b
a
b
a
b

colour
black
brown
black
red
black
orange
black
yellow
black
green
black
blue
black
violet
black
grey
brown
red

Pair-stranding
Pair-no.
core
19
20
21
22
23
24
25

a
b
a
b
a
b
a
b
a
b
a
b
a
b

colour
brown
orange
brown
yellow
brown
green
brown
blue
brown
violet
brown
grey
red
orange

X
X 53
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Colour code for single wire vehicle cables


one-colour
black, white, blue, orange, brown, green, violet, red,
pink, yellow, grey
base colour
longitudinal stripe
ring marking

two-colours
preferred colours

further colour combinations

base colour

marking colour
longitudinal stripe

base colour

marking colour
longitudinal stripe

base colour

marking colour
longitudinal stripe

base colour

marking colour
longitudinal stripe

white
white
white
white
white

grey
red
brown
blue
black

red
red
red
red
red
red

white
yellow
grey
green
blue
black

white
white
white

yellow
green
violet

brown
brown
brown

grey
violet
blue

yellow
yellow
yellow
yellow
yellow

grey
red
brown
blue
black

yellow
yellow
yellow

white
green
violet

blue
blue
blue

grey
violet
brown

brown
brown
brown
brown

white
yellow
green
black

grey
grey
grey

white
yellow
violet

black
black
black

grey
violet
brown

grey
grey
grey

green
red
brown

blue
blue
blue
blue

white
yellow
green
red

green
green
green

yellow
red
violet

green
green
green
green
green

white
grey
brown
blue
black

red

brown

black
black
black
black

white
yellow
green
red

violet
violet
violet
violet
violet
violet
violet

white
yellow
grey
green
brown
blue
black

orange
orange
orange
orange
orange
orange
orange

white
yellow
grey
green
violet
blue
black

three-colours
preferred colours

further colour combinations

base colour

1. marking colour
longitudinal stripe

2. marking colour
longitudinal stripe

base colour

1. marking colour
longitudinal stripe

2. marking colour
longitudinal stripe

grey
grey
grey

green
red
brown

yellow
yellow
yellow

grey
grey
grey

white
yellow
violet

yellow
yellow
yellow

red
red
red
red
red
red

white
yellow
grey
green
blue
black

yellow
yellow
yellow
yellow
yellow
yellow

red

brown

yellow

brown
brown
brown
brown

white
yellow
green
black

yellow
yellow
yellow
yellow

violet
violet
violet
violet
violet
violet
violet

white
yellow
grey
green
brown
blue
black

yellow
yellow
yellow
yellow
yellow
yellow
yellow

blue
blue
blue
blue

white
yellow
green
red

yellow
yellow
yellow
yellow

brown
brown
brown

grey
violet
blue

yellow
yellow
yellow

blue
blue
blue

grey
violet
brown

yellow
yellow
yellow

black
black
black
black

white
yellow
green
red

yellow
yellow
yellow
yellow

black
black
black

grey
violet
brown

yellow
yellow
yellow

orange
orange
orange
orange
orange
orange
orange

white
yellow
grey
green
violet
blue
black

yellow
yellow
yellow
yellow
yellow
yellow
yellow

Minimum quantities for one or two-coloured combinations per


cross-section and colour combination:
0,5 to 2,5 mm2 = 3 km
4,0 to 25,0 mm2 = 1 km. Remaining cross-sections on request
For three-coloured combination we manufacture only on request.
Minimum quantities per cross-sections and colour combinations:
0,5 to 2,5 mm2 = 5 km
4,0 to 25,0 mm2 = 3 km. Remaining cross-sections on request.

X 54
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Colour code HELUKABEL-JB


Colour coded Control Cables JB and SY-JB with green-yellow protective
conductor
The combination of colour identication up to 102 cores consists of 11 basic colours. For core-no. 12 and
more, one or two additional colour rings or longitudinal stripes are printed on the basic colour. The ring
width is approximately 2 mm.

3- to 5-core cables
Colour identication according to VDE 0293 for exible cables
3 cores = green-yellow/brown/blue
4 cores = green-yellow/brown/black/grey
5 cores = green-yellow/blue/brown/black/grey

6- and more core cables


Colour identication as per following table.
The insulation of the conductor gives the rst basic colour. The second and the third colour is printed on
the basic colour as a form of ring or longitudinal stripe. The cores are to be counted continuously through
all layers at the same direction, beginning with inner layer towards outside.
No. Basic-Ring-Colour

No. Basic-Ring-Colour

0
1
2
3
4
5
6
7
8
9
10
11

green-yellow
white
black
blue
brown
grey
red
violet
pink
orange
transparent
beige

36 transparent-blue
37 beige-blue

69 transparent-white-black
70 beige-white-black

38
39
40
41
42
43
44

grey-brown
red-brown
violet-brown
pink-brown
orange-brown
transparent-brown
beige-brown

black-white
blue-white
brown-white
grey-white
red-white
violet-white
pink-white
orange-white
transparent-white
beige-white

red-grey
violet-grey
pink-grey
orange-grey
transparent-grey
beige-grey

brown-white-blue
grey-white-blue
red-white-blue
violet-white-blue
pink-white-blue
orange-white-blue
transparent-white-blue
beige-white-blue

12
13
14
15
16
17
18
19
20
21

45
46
47
48
49
50

71
72
73
74
75
76
77
78
79
80
81
82
83
84
85

grey-white-brown
red-white-brown
violet-white-brown
pink-white-brown
orange-white-brown
transparent-white-brown
beige-white-brown

22
23
24
25
26
27
28
29
30

blue-black
brown-black
grey-black
red-black
violet-black
pink-black
orange-black
transparent-black
beige-scwarz

86
87
88
89
90
91

red-white-grey
violet-white-grey
pink-white-grey
orange-white-grey
transparent-white-grey
beige-white-grey

92
93
94
95
96

blue-white-red
brown-white-red
violet-white-red
pink-white-red
orange-white-red

31
32
33
34
35

brown-blue
grey-blue
red-blue
pink-blue
orange-blue

51 orange-red
52 transparent-red
53 beige-red
54
55
56
57

pink-violet
orange-violet
transparent-violet
beige-violet

58 transparent-pink
59 beige-pink
60 transparent-orange
61 beige-orange
62
63
64
65
66
67
68

blue-white-black
brown-white-black
grey-white-black
red-white-black
violet-white-black
pink-white-black
orange-white-black

No. Basic-Ring-Colour

97 brown-white-violet
98 orange-white-violet
99 brown-black-blue
100 grey-black-blue
101 red-black-blue

X
X 55

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Colour code HELUKABEL-OB


Colour coded Control Cables OB and SY-OB without green-yellow protective
conductor
The combination of colour identication up to 101 cores consists of 11 basic colours. For core-no. 12 and
more, one or two additional colour rings or longitudinal stripes are printed on the basic colour. The ring
width is approximately 2 mm.

2- to 5-core cables
Colour identication according to VDE 0293 for exible cables
2 cores = brown/blue
3 cores = brown/black/grey
4 cores = blue/brown/black/grey
5 cores = blue/brown/black/grey/black

6- and more core cables


Colour identication as per following table. The insulation of the conductor gives the rst basic colour. The
second and the third colour is printed on the basic colour as a form of ring or longitudinal stripe.
The cores are to be counted continuously through all layers at the same direction, beginning with inner
layer towards outside.
No. Basic-Ring-colour

No. Basic-Ring-colour

1
2
3
4
5
6
7
8
9
10
11

white
black
blue
brown
grey
red
violet
pink
orange
transparent
beige

36 transparent-blue
37 beige-blue

69 transparent-white-black
70 beige-white-black

38
39
40
41
42
43
44

grey-brown
red-brown
violet-brown
pink-brown
orange-brown
transparent-brown
beige-brown

black-white
blue-white
brown-white
grey-white
red-white
violet-white
pink-white
orange-white
transparent-white
beige-white

red-grey
violet-grey
pink-grey
orange-grey
transparent-grey
beige-grey

brown-white-blue
grey-white-blue
red-white-blue
violet-white-blue
pink-white-blue
orange-white-blue
transparent-white-blue
beige-white-blue

12
13
14
15
16
17
18
19
20
21

45
46
47
48
49
50

71
72
73
74
75
76
77
78
79
80
81
82
83
84
85

grey-white-brown
red-white-brown
violet-white-brown
pink-white-brown
orange-white-brown
transparent-white-brown
beige-white-brown

22
23
24
25
26
27
28
29
30

blue-black
brown-black
grey-black
red-black
violet-black
pink-black
orange-black
transparent-black
beige-black

86
87
88
89
90
91

red-white-grey
violet-white-grey
pink-white-grey
orange-white-grey
transparent-white-grey
beige-white-grey

92
93
94
95
96

blue-white-red
brown-white-red
violet-white-red
pink-white-red
orange-white-red

31
32
33
34
35

brown-blue
grey-blue
red-blue
pink-blue
orange-blue

51 orange-red
52 tranparent-red
53 beige-red
54
55
56
57

pink-violet
orange-violet
tranparent-violet
beige-violet

58 transparent-pink
59 beige-pink
60 transparent-orange
61 beige-orange
62
63
64
65
66
67
68

blue-white-black
brown-white-black
grey-white-black
red-white-black
violet-white-black
pink-white-black
orange-white-black

No. Basic-Ring-colour

97 brown-white-violet
98 orange-white-violet
99 brown-black-blue
100 grey-black-blue
101 red-black-blue

X 56
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Colour code according to DIN VDE 0813


Switchboard cable S-YY Lg

Switchboard cable S-Y(St)Y Bd

Core identication

Core identication

Dimensions in mm

Dimensions in mm
single coloured
no ring marking

a-core

with ring marking,


ring width and ring
distance
b-core

The cores are identied in colour-groups with each


4, 5, 6, 10 different core colour combinations which
is repeate continuously according to the following
scheme:

blue, red, grey, green, brown, black

10

blue, red, grey, green, brown, black,


yellow, white, pink, violet

Example
S-YY 30 (5 x6) x1x 0,6 Lg
= 5x colour-groups with 6 different core colours.
The colour-groups of same identication codes are
only permitted to apply in a cable. In each layer, the
blue core of the rst completed colour-group is
identied with red colour ring markings.
The remaining cores of the previous colour-group
are laying before the blue cores with red markings.
Counting: from outside towards inside.
The cores of the switchboard cable are stranded in
layers. The cores are to be counted continuously
through all layers at the same direction, beginning
with outer layer towards inside.

Identication of ring- and basic colours


No. of
Unit
1
2
3
4
5
6
7
8
9
10

Serial no. of
twistet elements

Ring-colours GBasic colour


a-core
a- and b-core

1
6
11
16
21
26
31
36
41
46

2
7
12
17
22
27
32
37
42
47

3
8
13
18
23
28
33
38
43
48

4
9
14
19
24
29
34
39
44
49

5
10
15
20
25
30
35
40
45
50
black

blue, red, grey, green, brown

brown

blue, red, grey, green

green

The colour identications of the a- and b-cores of


switchboard cables are coded with a basic colour
and colour rings.

yellow

Core colours

blue

No. of cores
in each colour-group

blue
yellow
green
brown
black
blue
yellow
green
brown
black

white

grey

Ring-colours b-core
all c-cores: red;
all d-cores: pink;
all e-cores: black

Cables with more than 50 twisted elements, the


identications code of 51 and above elements are to
be counted again from serial no. 1.
The twisted elements are pairs, triples, ve-core
units
Pairs a- and b-cores
triple a-, b- and c-ores
ve-core units a-, b-, c-, d- and e-cores
The cores of 5 twisted elements with same ring
markings of a-cores are bunched to a unit.
Counting: from outside towards inside.
The units are to be counted continuously through
all layers at the same direction with correct colour
countings, beginning with outer layer towards
inside.
X 57

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Colour code according to DIN VDE 0815


Installation Cables

Installation Cables

J-YY . . . Bd, J-HH . . . Bd, J-Y(St)Y . . . Bd,


J-H(St)H . . . Bd and J-2Y(St)Y . . . Bd

JE-Y(St)Y . . . Bd, JE-LiYCY . . . Bd, JE-H(St) . . . and


JE-HCH...Bd
Pair-colour-identication
The insulating cores are identied with different
basic colours which are repeated sequencely in
each unit.

The Insulating coverings of single cores of a star


quad are marked with black rings:

without printing

a-core
b-core
a-core
b-core

side circuit 1

side circuit 2

The cores of 5 star quads of a sub unit are counted


according to the sequence of basic colours:
Quad 1: basic colour of all cores red
Quad 2: basic colour of all cores green
Quad 3: basic colour of all cores grey
Quad 4: basic colour of all cores yellow
Quad 5: basic colour of all cores white
The marker of units are identied with a red helix,
the others with white or uncoloured.
The quads of sub units are counted according to
the sequence of basic colours. The units are
counted continuously through all layers beginning
in the inner layer.

Basic colours of pairs


Pair

a-core
b-core

blue
red

grey
yellow

green
brown

white
black

2-paired cables: the cores are stranded to a


star quad:
circuit 1: a-core blue
circuit 2: a-core grey
b-core red
b-core yellow
Each unit is assigned to one group of ring. All cores
in each unit are marked with coloured rings and
ring-groups.
Counting direction in all units is from inside to
outside.

Ring-colour and Ring-group


Ring-group 1
Ring-group 2
Ring-group 3
Ring-group 4

Installation Cables
J-Y(St)Y . . . Lg
2-paired installation cables are stranded to a
star quad.
circuit 1 a-core red, b-core black
circuit 2 a-core white, b-core yellow

3- and multi-paired installation cables


a-core of 1. pair in each layer is red
other pairs are white
b-core blue, yellow, green, brown, black in
continuous repeat
Counting: from outside to inside

Unit-identication
UnitNo.

Ringcolour

Ringgroup

Colouridentication tape

1
2
3
4

pink

I
II
III
IIII

5
6
7
8

orange

I
II
III
IIII

9
10
11
12

violet

I
II
III
IIII

13
14
15
16

pink

I
II
III
IIII

blue

17
18
19
20

orange

I
II
III
IIII

red

Cables with more


than 12 units
contain coloured
plastic helix in
addition to ring
code.

X 58
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Colour code according to DIN VDE 0816 and extended


Outdoor Telephone Cables
A-2Y(L)2Y...Bd and A-2YF(L)2Y...Bd
A-02Y(L)2Y . . . Bd, A-02YSF(L)2Y . . Bd and A-2Y0F(L)2Y . . . Bd
The Insulating coverings of single cores of a
quad are to be marked with black rings:
without printing

a-core
b-core
a-core
b-core

Desing of a main-unit:
Consist of 10 sub-units = 100 pairs (DA)
1 star quad

side circuit 1

side circuit 2

1 sub-unit of
5 star quads (10 DA)

The insulating cores of ve star quads of a sub-unit


must have the following colours:
Quad 1: basic colours of all conductors red
Quad 2: basic colours of all conductors green
Quad 3: basic colours of all conductors grey
Quad 4: basic colours of all conductors yellow
Quad 5: basic colours of all conductors white
The rst sub- or main-unit in each layer is to be marked by an open helix of plastic tape of red (marker).
All other sub- or main-units must be whipped with
an open helix of white or uncoloured plastic tape.
The quads of a sub-unit are to be counted according
to the sequence of basic colours.
In cables with more than 5 star quads, the sub- and
main-units must be counted continuously beginning
with maker-unit at inner layer towards outside.

Design of a 300-pairs cable:


Consist of 6 main-units, each of 50 pairs (DA)
1 sub-unit of
5 star quads (10 DA)

1 main-unit of
5 sub-units

Design of a sub-unit:
Consist of 5 star quads = 10 pairs (DA)
(DA = double core or pair)

1 star quad

Design of a 1500-pairs cable:


Consist of 15 main-units, each of 100 pairs (DA)
1 sub-unit of
5 star quads (10 DA)

Design of a main-unit:
Consist of 5 sub-units = 50 pairs (DA)

1 main-unit of
10 sub-units

1 star quad

X
X 59
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Colour Abbreviations according to VDE and IEC


It is planned to use in future an uniform common colour abbreviations according to IEC 60757 (identical to
CENELEC-harmonized document HD 457).
The following table shows the comparison of German and IEC colour abbreviations:
colour

German abbreviation
new
old

Abbreviation
according to IEC 60757

black

SW

sw

BK

brown

BR

br

BN

red

RT

rt

RD
OG

orange

OR

or

yellow

GE

ge

YE

green

GN

gn

GN
BU

blue

BL

bl

violet

VI

vi

VT

grey

GR

gr

GY

white

WS

ws

WH

pink

RS

rs

PK

turquoise

TK

tk

TQ

IEC = International Electredechnical Commission

Identication of the core according to DIN VDE 0293 and core colour to DIN 47002 and IEC 60304
Wiring cable with a nominal voltage U0/U 300/500 V
The following colours have been recommended: black, white, blue, grey, brown, red, orange, turquoise,
violet and pink.
Exceptions are green and yellow which are only admitted to be used, if the safety regulations permit.
The colour green is allowed to use for illuminations and light decorations.
All two-colour combinations of the above single colours are allowed to be used.
Single core cables with a nominal voltage U0/U 450/750 V
The following single colours have been recommended (only of one colour)
black, white, blue, grey, brown, red, orange, turquoise, violet and pink.
Two-colour combinations are not allowed to be used, with the exception of green-yellow.
Single core cables and single core sheathed cables
The colour is black or green-yellow.
The exception is for illumination and light decorations where the core colour brown is permitted.
Identication of the cores through colours
are allowed:
a) through colouring the whole insulation compound or
b) through colouring the outer surface or
c) through coloured tapes, so far it is specied in the standards
By identication through colouring only on outer surface (item b) but not allowed to have any colour
additives beneath the insulation with an exception by double colour coding.
By core identication with green-yellow, one of the colours have to cover not less than 30% and the other
not more than 70% of the surface.
Identication through number coding
The printing of numberings on cores consists of repeating codes (with number and dashes), printed
longitudinally on core (for coordination and dimensions see DIN VDE 0293)
Note
The following core identications are valid for power cables with nominal voltage up to 1000 V. Scopes for
valid DIN VDE prescription:

DIN VDE 0250 Insulated power cables


DIN VDE 0255 Cables with paper-insulation and metal sheath
DIN VDE 0265 Cables with PVC-insulation and lead sheath
DIN VDE 0266 Halogene-free cable with improved characteristics in case of re
DIN VDE 0271 Cable with PVC-insulation and PVC outer jacket 0,6/1 kV
DIN VDE 0272 XLPE-insulated cable
DIN VDE 0281 PVC-insulated power cable
DIN VDE 0282 Rubber-insulated power cable

X 60
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Identication of insulated wires by colours


according to DIN 40705 and CEI/IEC 60446
Core identication
The core identication of different conductors such as Phase conductor, Mid-point conductor, PENconductor and Predective conductor are distinguished by the indicating letters and colours of the core.
An universal international norm exists only for the green-yellow earthing (grounding) conductor.
For new installation it is not allowed to use the old core colours.
Conductor designation

Alphanumerical type

Colour identication

Symbol

Alternating current

old

new

old

new

Phase conductor 1

L1

black

not dened
(preferred colour black1)

Phase conductor 2

L2

red

not dened
(e. g. brown1)

Phase conductor 3

L3

blue

not dened

Mid-point conductor

MP

grey

light blue2)

Positive

L+

not dened

Negative

not dened

Mid-point conductor

Direct current

light blue2)

Protective conductor

PE

green-yellow3)

Neutral conductor
with protection

PEN

green-yellow3)

Earth (ground)

not dened

Earth for
external voltage

TE

not dened

Load-Connecting
clamps

to L1
to L2
to L3
to N

U
V
W
N

1)

Application of conductors by colours black or brown for internal wiring of single core cables
For the internal wiring of apparatus, distributor boards and equipment with the insulated single cores, only the black-colour is preferred. Application of other colours or
combinations of two other colours are also provided, if these for the purpose of manufacturing or services are necessary.
If only an additional colour for the individual identication of separated conductor group is necessary, the colour brown is preferred.
2)
Application of the colour light blue
Where a circuit includes a neutral or mid-point conductor identied by colour, the colour used for this purpose shall be blue. In order to avoid confusion with other colours it is
recommended to use an unsaturated colour blue, called here light blue. Light blue shall not be used for identifying any other conductor where confusion is possible.
In the absence of a neutral or mid-point conductor, a conductor identied by light blue within the whole wiring system may also be used for any other purposes, except as a
predective conductor.
If identication by colour is used, bare conductors used as neutral or mid-wire conductors shall be either coloured by a light blue stripe, 15 mm to 100 mm wide in each unit or
enclosure and each accessible position, or coloured light blue throughout their length.
3)
Application of bi-colour combination green-yellow
The bi-colour combination green-and-yellow shall be used for identifying the predective conductor and for no other purposes. Green-and-yellow is the only colour combination
recognised for identifying the predective conductor, according to DIN VDE 0293. The combination of the colours green-and-yellow shall be such that, on any 15 mm length of
the conductor where colour coding is applied, one of these colours cover at least 30% and not more than 70% of the surface of the conductor, the other colour covering the
remainder of that surface.
If bare conductors, used as predective conductors, are provided with colouring they shall be coloured green-and-yellow, either throughout the whole length of each conductor
or in each compartment or unit or at each accessible position. If adhesive tape is used, only bi-coloured tape shall be applied.

X
X 61
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Permissible minimum bending radius


according to DIN VDE specications
The indicated values for bending radius stated in the following table are not permitted to fall below the
value. For non-complience of the values a short longevity is to be expected.
Permissible minimum bending radius for power cables according to DIN VDE 0298 part 3
Nominal voltage 0,6/1 kV
Cables for xed installation
method of laying

Outer of cables or thickness of at cable in mm (D)


up to 10 mm
> 10 to 25 mm

> 25 mm

for permanent laying

4xD

4xD

4xD

to form out

1xD

2xD

3xD

for exible cables

up to 8 mm

> 8 bis 12 mm

> 12 to 20 mm

> 20 mm

for xed installation

3xD

3xD

4xD

4xD

for free movement

3xD

4xD

5xD

5xD

to the inlet

3xD

4xD

5xD

5xD

for forced guiding operation


(such as trailing)

5xD

5xD

5xD

6xD

operation for trolly cable

3xD

4xD

5xD

5xD

operation in power drag chain


operation for return sheave

4xD

4xD

5xD

5xD

7,5 x D

7,5 x D

7,5 x D

7,5 x D

D = outer of cables or thickness of at cable

Permissible minimum bending radius according to DIN VDE 0891 part 5


for installation cable and wires according to DIN VDE 0815
Type

for transport

repeated bending
under stress

J-Y(St)Y . . . Lg

bending for one


time without stres
5xD

JE-Y(St)Y . . . Bd
JE-H(St)H . . . Bd
JE-H(St)H . . . Bd FE
JE-YCY . . . Bd
JE-HCH . . . Bd
JE-LiYCY . . . Bd

7,5 x D

7,5 x D

2,5 x D

JE-LiHCH . . . Bd
JE-LiYY . . . Bd
JE-LiHH . . . Bd
J-YY . . . Bd
J-HH . . . Bd
J-Y(St)Y . . . Bd
J-H(St)H . . . Bd
D = outer of cable
Note: For the individual application above the range of specication, the indications in respect of cable recommendations should be
considered.

X 62
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Chemical Resistance of PUR (Polyurethane)


Substance
Aceton
Alums
Aluminium chloride
Formic acid
Ammonia
Ammonium carbonate
Ammonium chloride
Aniline
ASTM-Oil I
ASTM-Oil II
ASTM-Oil III
ASTM-Fuel No. I
ASTM-Fuel No. II
ASTM-Fuel No. III

Concentration
(%)



10
30
10
















Benzene
Brake uid ATE
Butanol
Butyl acetate
Calcium chloride
Chlorobenzene
Chloroform
Chloroprene
Chromic acid
Cyclohexan
Cyclohexanon

Classication
of
requirement

40







Substance
Magnesium chloride
Methanol
Mythyl acetate
Mythyl chloride
Methylethylketon
Mythylglycol
Mythylglycolacetate
Lactic acid
Mineral oil
Motor oil

Concentration
(%)
30
<5

10

Classication
of
requirement







*


Sodium chloride
10
Sodium perchlorate solut.
Soda lye
10




Olive oil
Ozone




Parafn oil
Perchlore ethylene
Petroleum ether
Petroleum
Vegetable oils
Vegetable fats
Phosphoric acid





50





Nitric acid
30
Hydrochlorid acid, concen.
Cutting oil
Carbon disulde
Sulfuric acid
30
Sea water
Silver salts
20



*










Tetrachloroethylene
Carbon tetrachloride
Tetrahydrofuran
Toluene
Trichlorethylene







Freon 12
Freon 22




Tataric acid

Hydraulic oil SAE 90


Glycerin
Glycol

*






Diethylether
Diethylprestone
Diesel oil
Dimethylformamide
Ferric-III-chloride
Acetic acid 2080
Ethanol
Ethyl ether
Ethylacetate
Ethylencloride


10
10
100

Xylon

Isopropanol

Potash lye
10
Bichromate of potash
Potassium nitrate
Potassium permanganate
Kerosene





100

< 10




resistant

vastly resistant
conditionally resistant

not resistant

*for individual case, please verify

The information mentioned in this summary is given to the best of our own knowledge
and based upon our long standing experience. But we would like to direct your
attention to the fact, that the information is given without obligation. A nal judgement can only be made in practice.

X 63
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Silicone

J-H(St)H, Security Cable ..E 30/E 90, HELUCOM-H


JZ-500-HMH/MXMHX, N2XH, H072-K, RG-H

SiHF, SiHF/GL-P, SiF, SiD, SiFF, SiF/GL, SiD/GL,


SiHF-C-Si, FZ-LS, FZ-LSi, N2GMH2G

Neoprene-Round/Flat, NSHTU, AIRPORT 400 Hz


H01N2-D/E, H 05/H 07-, A 05/A 07 RN-F

FEP-6Y, PTFE-5Y, Compensating cables-FEP

PUR

PUR-JZ, PUR-JZ-HF, TOPFLEX-PUR, ROBOFLEX,


SUPERTRONIC-PUR, MULTIFLEX-PUR, TOPSERV

Neoprene HELURubber FLON

PE

Coaxial-cable (PE), L2-BUS-cable (PE)


A-2Y(L)2Y, A-2YF(L)2Y, HELUCOM ... 2Y

THERM 120, THERM 105, H05V2-K, H07V2-K

H 05 V-K, H 07 V-K, H 03 W-F, H05 W-F

ESUY, LifY, PVC-Single cores, EDV-PiMF-CY


ESY, LiFDY, TUBEFLEX/-CY

F-CY-JZ, Y-CY-JZ, JZ-HF-CY, J-Y(St)Y, J-YY, JE-Y(St)Y


S-YY, S-Y(St)Y, TOPFLEX-PVC

JZ-602, JZ-602-CY, TGRONIC-CY, LiYCY, JZ-602 RC,


PAAR-TRONIC-CY, SY-JZ, SY-JB, JZ-602 RC-CY

Lify, Trago, Lift-2S, BAUFLEX


BUS-cables-PVC, DAT-cables-PVC

H05W5-F, H 05WC4V5-K

JZ-603, JZ 603-CY, Li-TPC-Y,


PAAR-CY-OZ, N05W5-F, CEI 20-22

Temperature up to --- C

Concentration (%)

Chemical
Resistance

JZ-500/600/750, JB, OZ-BL, JZ-HF


PVC-Flach, TRONIC (LiYY), SUPERTRONIC-PVC

PVC

Substance
Inorganic chemicals
Alums

colts.

20

Aluminium salts

each

20

Ammonia, wat.
Ammonium acetate, wat.

10

20

each

20










Ammonium carbonate, wat.

each

20

Ammonium chloride, wat.

each

20

Barium salts

each

20

Boric acid

100

20

Calcium chloride, wat.

colts.

20

Calcium chloride, wat.

10 40

20

Calcium nitrate, wat

colts.

20

Chromium salts, wat.

colts.

20

20

Potassium carbonate, wat.




Potassium chlorate, wat.

colts.

20

Potassium chloride, wat.

colts.

20

Potassium dicromate, wat.

20

Potassium iodie, wat.

20

Potassium nitrate, wat.

colts.

Potassium permanganate, wat.


Potassium sulphate, wat.
Copper salts

colts.

Megnesium salts

colts.

Sodium bicarbonate (Natron), wat.





20

20




20

20

20

20

Sodium thiosulfat, wat.

20

Nitrobenzene




20

Sodium bisulphite (Soda), wat.

Soda Lye




20

Sodium chloride (Cook salt), wat.

Nickel salts, wat.




50

50

colts.

20

100

50




Phosphoric acid

50

20

Mercury

100

20

colts.

20

Mercury salts
Nitric acid
Hydrochlorid acid

30

20

conc.

20

Sulfur dioxide

20

Carbon disulde

20

50

Sulfuric acid

50




Hydrogen sulde

20

Sea water

20

Silver salts, wat.

20

Cleaning uid lye


Water (dest.)

100

20

Hydrogen peroxide, wat.

20

Zinc salts, wat.

20

Stannous chloride

20




*

resistant
each = each concentration
conditionally resistant
colts. = cold saturated
not resistant
wat. = watery, liquid
for individual case, please verify





The information mentioned in this summary is given to the best of our own knowledge and based
upon our long standing experience. But we would like to direct your attention to the fact, that the
information is given without obligation. A nal judgement can only be made in practice.

X 64
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Aniline

50

Petrol

20

Benzene

50

HELURubber FLON

Neoprene

FEP-6Y, PTFE-5Y, Compensating cables-FEP

Silicone

Neopren-Round/Flat, NSHTU, AIRPORT 400 Hz


H01N2-D/E, H 05/H 07-, A 05/A 07 RN-F

SiHF, SiHF/GL-P, SiF, SiD, SiFF, SiF/GL, SiD/GL,


SiHF-C-Si, FZ-LS, FZ-LSi, N2GMH2G

PUR

J-H(St)H, Security Cable ..E 30/E 90, HELUCOM-H


JZ-500-HMH/MXMHX, N2XH, H072-K, RG-H

20

PE

PUR-JZ, PUR-JZ-HF, TOPFLEX-PUR, ROBOFLEX,


SUPERTRONIC-PUR, MULTIFLEX-PUR, TOPSERV

THERM 120, THERM 105, H05V2-K, H07V2-K

H 05 V-K, H 07 V-K, H 03 W-F, H 05 W-F

ESUY, LifY, PVC-Single cores, EDV-PiMF-CY


ESY, LiFDY, TUBEFLEX/-CY

F-CY-JZ, Y-CY-JZ, JZ-HF-CY, J-Y(St)Y, J-YY, JE-Y(St)Y


S-YY, S-Y(St)Y, TOPFLEX-PVC

Lify, Trago, Lift-2S, BAUFLEX


BUS-cables-PVC, DAT-cables-PVC

20
30

H05W5-F, H05WC4V5-K

Temperature up to ...C

JZ-603, JZ 603-CY, Li-TPC-Y,


PAAR-CY-OZ, N05W5-F, CEI 20-22

Concentration (%)

JZ-500/600/750, JB, OZ-BL, JZ-HF


PVC-Flat, TRONIC (LiYY), SUPERTRONIC-PVC

Chemical
Resistance

JZ-602, JZ-602-CY, TGRONIC-CY, LiYCY, JZ-602 RC,


PAAR-TRONIC-CY, SY-JZ, SY-JB, JZ-602 RC-CY

PVC

Coaxial-Cable (PE), L2-BUS-cable (PE)


A-2Y(L)2Y, A-2YF(L)2Y, HELUCOM ... 2Y

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Substance
Organic chemicals
Aceton
Formic acid

Succinic acid, wat.

colds.

Brake uid

20

100







1)

20

Chlorobenze

30

Chloroprene

20

Diethylether

20

Diethylprestone

50

50

20

Ethyl chloride

50

Ethylene glycol

100

Freon

20

Acetic acid

20

Ethyl alcohol

100







20

100

20

*


20

20

10

*

20
100

20

Methylen chloride

Machine oil




*

Mineral oil
Motor oil

120

Olive oil

50

20

Oxal acid

Methanol

Lactic acid




50

Kerosene

Methyl alcohol




100

Hydraulic oil
Isopropyl alcohol




each

Gear oil
Glycerin

50

20

Butane

Glacial acetic acid




Butter

Diesel oil




colds.










Parafn oil
Vegetable oils

Vegetable fats

*

20

100

20

100

20

Tartaric acid, wat.

Citric acid

Cutting oil
Tar acid
Carbon tetrachloride




Toluene
Trichloroethylene




*
1)

resistant
each = each concentration
conditionally resistant
colds. = cold saturated
not resistant
wat. = watery, liquid
for individual case, please verify
PUR-material is resitant

The information mentioned in this summary is given to the best of our own knowledge and based
upon our long standing experience. But we would like to direct your attention to the fact, that the
information is given without obligation. A nal judgement can only be made in practice.

X
X 65

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Chemical Resistance of Fluorinated


polymeric materials
The Fluorinated polymeric is resistent against following chemical materials
Abietin acid
Acetone
Acetone phenon
Acetic anhydride
Acetic acid
Acryl hydride
Allylic acetate
Allylic metacrylacid
Aluminium chloride
Ammonia, liquid
Ammonium chloride
Aniline

Ethyl ether
Ethyl alcohol
Ethyl acetate
Ethylene bromide
Ethylene glycol

Benzene chloride
Benzonitrile
Benzyl alcohol
Borax
Bromine
Butyl acetate
Butyl

Hexane hydrazine
Hydrochlorid acid
Hydrogen superoxide

Calcium chloride
Carbon bisulde
Cetane
Chlorine
Chloroform
Chlorosulfonic acid
Chromic acid
Cyclohexan
Cyclohexanon

Magnesium chloride
Mercury
Metacryl acid
Methanol
Methyl ethyl keton
Methyl metacryl acid

Diethyl Carbonate
Dibutyl-Phthalide
Dibutyl-Sebacat
Di-isobutyl Adipt
Dimethyl ether
Dimethyl Formamide
Dimethyl hydrazine
Dioxane
Esachloroethane
Ethyl Exoate

Ferric chloride
Fluoride naphthalene
Fluoride nitrobenzene
Fomaldehyde
Formic acid
Furan

Iron phosphide
Lead

Naphtalene
Naphthole
N-Butylamine
Nitric acid
Nitromethane
Nitrogen tetroxyde
not synthetic nitrobenze
N-octadecyal alcohol
2-Nitro butanol
2-Nitro-Methyl propanol

Pentachloro benzamide
Perchloro ethylene
Permanganate
Petrol Phenol
Phosphorus pentachloride
Phosphoric acid
Phthalic acid
Pinene
Piperidine
Potassium
Potassium acetate
Potassium hydroxide
Polyacryonitril
Pyridine
Stannous chloride
Sodium hydroxide
Sodium hydochloride
Sodium peroxide
Solvents
Soaps
Sulfur
Sulfuric acid
Tetra bromothane
Tetrachlorethane
Triethanolamine
Trichloracetic acid
Trichloroethylene
Tricresylic phosphate
Vinylmetracrylate
Washing mediums
Water
Xylol
Zinc chloride

Oils, from vegetables


Oils, from animals
Ozone

The following chemical substance attack no Fluorinated polymeric


Ethyl alcohol
Vapour
Hydrouoric acid
Aviation gasoline
Hydraulic liquid-Skydrol
Isopropyl alcohol
Carbon chlorid

Soda
Crude petroleum
Nitric acid concentr.
Sea water
Sulfuric acid (30%)
Transformer Oil
Turbine fuel JP 4

The information mentioned in this summary is given to the best of our own knowledge and based upon
our longstanding experience. But we would like to direct your attention to the fact, that the information is
given without obligation. A nal judgement can only be made in practice.
X 66
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fluorinated polymeric materials:


PTFE, FEP, PFA, ETFE
The chemical resistance of polymers with a high uorine content is exceptionally high. The electrical insulating and dielectric properties of these materials are also very good.
Fluorpolymere Werkstoffe sind: HELUFLON-PTFE, HELUFLON-FEP, HELUFLON-PFA, HELUFLON-ETFE

HELUFLON-PTFE
HELUFLON-FEP
HELUFLON-PFA
HELUFLON-ETFE

Polytetrauoroethylene (5Y)
Tetrauoroethylene peruoropropylene copolymer (6Y)
Tetrauoroethylene peruoroalkoxy copolymer (51Y)
Ethylenetetrauoroethylene copolymer (7Y)

Fluorpolymere is resistant against nearly all known chemical compounds.


Fluorpolymere has a smooth surface of extremely low surface tension which is why virtually nothing
adheres to this material.
Fluorpolymere is moisture rejecting, doesnt swell and is not be damaged by welding.
Fluorpolymere is used, where conventional material wouldnt resist the environmental conditions.
Fluorpolymere is applied in the civil and military sector as well as in the aviation- and astronautics
technology.
Fluorcarbonresins have following important characteristics::
high heat-resistance during permanent operation
HELUFLON-FEP
up to 205 C
HELUFLON-PTFE
up to 260 C
outstanding resistant against dielectric strength
constant dielectric characteristics
no moisture absorption
resistant against nearly all chemical products
insensitive to environmental inuences, weatherproof and resistant to irradiation from the sun and
temperature uctuations
good mechanical characteristics, no formation of cracks, wear-resistant
low coefcient of friction
no action of light (also uv)

1)

Breaking point
%( 20C)

Porosity
%( 20C)

Environmental resistance

Flammability

Resistance
to
chemicals

Radiation
resistance 1)
x104 GY

51Y

Tension
MPa (20C)

PFA

Break-down resistance
kV/ mm (20C)

5Y

Specic
resistance
Ohm cm (20C)

PTFE

Density
103 kg/ m3 (20C)

6Y

Dielectric number
at 60 Hz (20C)

FEP

Break-down
temperature, melting
point (C)

7Y

Nominal temperature
temporary (C)
(hours)

ETFE

Nominal temperature
permanent (C)
approx. 25000 h

Material initial code

Insulation material

Characteristics

100
+150
100
+205
190
+260
190
+260

+180

+270

2,6

1,70

1016

36

45

150 300

0,02

very good

n.e.f.

very good

200

+230

+290

2,1

2,15

1018

25

20 25

250 300

0,01

very good

n.e.f.

very good

0,02

+300

+327

2,0

2,18

1018

20

35 45

350 400

0,01

very good

n.e.f.

very good

0,02

2,20

16

25

30

300

0,01

very good

n.e.f.

very good

0,02

+280

Values shown include high dosage


and ca. 50% rest smoldering values

+310

2,1

10

n.e.f. = no ammable

Insulation and jacket type abbreviations


DIN/VDE
7Y
6Y
5Y
51Y

Material
ETFE
FEP
PTFE
PFA

X
X 67
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Chemical Resistance of Silicone


Substance
Acetamide
Acetone
Aniline
Petrol
Brake uid AT
Butanol
Butylacetate
Calcium hydroxide, (saturated)
Chlorbenzene
Cloroform
Clophene
Vapour up to 2,5 at
Diphenyl
Diesel oil
Dinamo oil
Mineral oil
Acetic acid
Hydrouor acid 5%
Gear oil DTE BB
Gear oil DTE HH
Gear oil DTE extra heavy
Gear oil Type SEA 90
Prestone
Glycerin
Hexa ethoxydisiloxane
High pressure compressor oil
Isopropyl alcohol
Potassium 20%
Potassium hydroxide 50%
Potassium permanganate solution
Carbolineum
Cooking salt solution 10%
Carbon tetrachloride
Compressor oil, light
Ball bearing fat
Linseed oil

Test period
7 days
Temperature C
150
20
100
20
100
117
20
20
20
20
150
138
150
20
150
20
20
20
150
150
150
150
20
100
20
150
82
20
20
20
20
20
20
150
150
100

 lresistant
 conditionally resistant
 not resistant

Classication
of
requirement





































Test period
7 days
Temperature C
65
20
150
150
150
150
150
150
20
20
20
150
150
20
20
20
60
20
20
150
150
20
20
20
20
20
20
20
20
20
150
20
20
150
100

Substance
Methanol
Methylen chloride
Mineral oil ASTM No. 1
Mineral oil ASTM No. 3
Mineral oil SEA 10
Mineral oil SEA 20
Mineral oil SEA 30
Motor oil viscose static
Sodium 20%
Soda 50%
Nitrobenzene
Oleic acid
Olive oil
Perchlor
Petroleum ether
Petroleum
Phenol
Phosphoric acid 30%
Pyridine
Regulator oil
Castor oil
Hydrochlorid acid 10%
Nitric acid conc.
Nitric acid 10%
Sulfuric acid, conc.
Sulfuric acid, 10%
Shock absorber oil
Styrol
Turbentine oil
Toluene
Transformer oil
Tri
Tri glycol
Vaseline
Water

Classication
of
requirement




































The information mentioned in this summary is given to the best of our own knowledge
and based upon our long standing experience. But we would like to direct your attention
to the fact, that the information is given without obligation. A nal judgement can only
be made in practice.

Resistance of substances against solvents,


oils and fats
Substance

PVC
Y

















Alcohol, methylated spirit


Brake uid for vehicles
Bromide chloriduormethane
Jet gasoline IP4
de-icing and icing protective agent
Aircraft lubricating grease
Hydraulic oil on bas of mineral oil
Hydraulic liquid (chlor-free silicone liquid)
Hydraulic liquid (synthetic)
Methylethylketon
Otto-gasoline, diesel gasoline
Lubricating oil for recebrocating engine SAE 10 W
Lubricating oil for jet engine (synthetic)
Toluene-Isooctane (Toluene 30%, Isooctane 70%)
Trichlorethane
Urine
 lresistant
 conditionally resistant
 not resistant

PVC = Polyvinylchloride Y
PA
= Polyamid 4 Y
PTFE = Polytetrauorethylene 5 Y

PA
4Y

















PTFE
5Y

















FEP
6Y

















ETFE
7Y

















FEP = Fluorethylenepropylene 6 Y
ETFE = Tetrauorethylene 7 Y

X 68
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Halogen-free Security Cables and Wires


What are halogens?
Halogens formation of salt are the elements as
uorine, chlorine, bromine and iodine.
Fluorine and chlorine are important for cables and
wires as atoms in the plastic molecules, for example
uorine plastics or PVC (polyvinyl chloride) are of
signicance; and bromine as component of ame
protection additives.
When is a cable halogen-free ?
The burning behaviour of cables and wires is very
important for the installation in buildings and also
in control plants.
Thereby the following points are very
important:
Behaviour under ame inuence i. e. the inammability as well as the propagation of re
Subsequent damage by formation of corrosive
and toxic gases
Development of smoke density (darkening of
emergency exits hindered the re extinguishing
works)
Cables produced of not halogen-free (halogenated)
materials such as mainly the materials with chlorine
in the molecule-chain: Polyvinyl chloride (PVC),chloroprene rubber (CR), chlorinated polyethylene (CM),
chlorsulfonated polyethylene (CSM) and uorhydrocarbons.
Polytetrauorethylene (PTFE)
Fluorethylenepropylene (FEP)
Peruoralkoxypolymeric (PFA)
These materials have a better behaviour in case of
re.

hydrocarbons. By burning such kind of materials,


produce no corrosive and toxic gases but only water
vapour and carbondioxide.
Polymers like polyethelene (PE) or polypropylene
(PP) are halogen-free. These materials are easy
ammable and not self-extinguishing.
Halogen-free cables for the security requirements
must be hardly ammable and self-extinguishing.
This happens by using the special polymer
compounds, containing the considerable
percentage of ame protective materials.
Such kind of protective materials consist for
example, of an aluminium hydroxide which on one
side cools the re location by setting free of crystal
water and on the other side the released water
vapour hinders the admittance of oxygen and
thereby this suffocates the ame. By using of additional supporting tapes and lling yarns of glass
web, mica and similar materials the functionallity for
example of E 90 can be realised with the suitable
cable accessories.
Application
The application of halogen-free security cables and
wires are specied more and more with increasing
numbers for the buildings where people gather or
everywhere, where safety conciousness to protect
the human life and valuable materials take a special
signicance. For example,
Hospitals, airports, in multi-storey buildings, stores
and shops, hotels, theaters, cinemas, schools etc.
Fire warning plants, alarm systems, ventilation systems, escalators, lifts, safety lights, operation and
intensive stations, maintenance equipment
Underground railways and other railway plants

These are hardly combustible or not ammable and


vastly self-extinguishing. Due to this effect and in
case of re the released molecules constituents
chlorine and uorine, which hinder the admittance
of oxygen to the re location and suffocate the
ame.

Data processing installations

The remarkable disadvantages of these materials


are existing in the fact that the released chlorine
and orine atoms composite themselves with
hydrogen which is decomposed from plastic material as well as with hydraulic acid or hydrooric acid
from the existing air.

Shipbuilding and offshore plants

These compositions are extremely corrosive and


also toxic. In consequence the damages by corrosion are often higher than the actual damage
caused by re.
Halogen-free cables contain no halogens, i. e. the
insulation and sheath materials of these cables are
composed with polymers on the basis of pure

Power stations and industrial plants with high


valuable machines and materials or risky potentials
Mining works

Emergency power supply works


HELUKABEL-Security Cables and
Wires and the advantages
Flame retardant and hardly combustibility so
that no ame propagation in case of re can be
resulted
Halogen-free; no evolution of corrosive gases
In case of burning, the halogen-free cables emits
low smokeG
X 69

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Halogen-free Security Cables and Wires


The danger of toxic gases caused by re is far
inferior

Test method A test on single cable


IEC 60332-2

Low caloric load

Test sample of 600 mm cable length shall be in a


position vertically hanging. A propane gas burner
( 8 mm) shall be at an angle of 45 to the axis
and the ame of approx. 100 mm below the lower
edge of the sample. Flame inuence max. 20 s.

Remarkable longer electrical functionallity and


ame inuence
Insulation integrity for at least 30 minutes as well
as 180 minutes at 800C under re condition
Suitable for emergency service up to 180 minutes
Radiation resistance up to 200 x 106 cJ/kg (up to 200 Mrad)
These characteristics are obtained by using of a exible halogen-free basis material aluminium hydroxide Al (OH)3 .
Caloric load values
(heat of combustion)
For designing a building the criterions of the caloric
load values are very important. The caloric load
values of the modern halogen-free cables are
reduced by corresponding additives.
The specic heating values of the non-metallic raw
materials for cables are specied to DIN 51900. The
values of the caloric load or heat of combustion for
electrical cables are given per running meter in the
following tables.
Combustible cable insulations or open building
materials of class B1 are regarded as harmless so
far as the resulted caloric load is distributed as
proportionale as possible and is valid  7 kWh/m2
The conversion of the values:
1 MJ/m2
1 kWh/m2

 0,278 kWh/m2
 3,6 MJ/m2

Regulations
According to DIN VDE 0108 supplement 1:
The total caloric load of the cables are allowed up
to 14 kWh per m2 of the eld areas if only halogen-free cables with improved characteristics in
the case of re are used.
If you use PVC cables the total caloric load is only up
to 7 kWh per m2
Tests
The characteristics of the security cables are tested
according to DIN VDE specications:
Behaviour in re
According to DIN VDE 0472 part 804, test method A,
test method B and test method C.

The test is passed, if the sample has not burned


or the ame extinguished by itselfs and the
damage by re doesnt reach the remotest upper
side of the sample.
PVC self-extinguishing and ame retardant
according to VDE 0482-332-1-2 DIN EN
60332-1-2 7 / IEC 60332-1 (equivalent to DIN
VDE 0472 Teil 804 test method B).
Test sample of 600 mm cable length shall be in a
position vertically hanging. A propane gas burner
( 8 mm) shall be at an angle of 45 to the axis
and the ame of approx. 100 mm below the lower
edge of the sample. Flame inuence, depending
on cable weight, 1 to 2 minutes.
The test is passed, if the sample has not burned
or the ame extinguished by itselfs and the
damage by re doesnt reach the remotest upper
side of the sample.
Test method C test on bunched cables
similar IEC 60332-3, HD 405.3, DIN EN
60332-3, VDE 0482-332-3
Test samples of 360 cm cable length are laying
parallel side-by-side attached to a test-ladder,
which is hanging vertically with a distance of
150 mm to the furnace. The sample should be
amed with a ame length of 60 cm on the test
sample at approx. temperature 800C by a burner
width of approx. 250 mm. The test duration
should be 20 minutes.
The test is passed, if the sample has not burned
or the ame extinguished by itself and the
damage by re does not reach the remotest
upper side of the sample.
Corrosivity of cumbustion gases
According to VDE 0482 part 267/DIN EN 50267-2-2 /
IEC 60754-2 (is equivalent to DIN VDE 0472 part 813).
For the performance of the test procedure the
insulation and sheath materials are to be put in the
moveable furnace, preheated to 750 to 800C. The
burning gas is conducted through two gas-washing
bottles.
The test shall be regarded as passed when the
measured pH-value is  4,3 and the electrical
conductivity  100 S.cm-1.
During this test all the not desired components of
the materials are precipitated such as all halogens, sulphur and nitrogen.

X 70
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Halogen-free Security Cables and Wires


Continuance of insulation effect
under direct re conditions
According to DIN VDE 0472 partl 814 IEC 60331
Test sample of 1200 mm cable length is xed in a
horizontal position, 75 mm over the gas brenner.
The rated voltage of 3 A fuse is xed between the
core groups. The burner ame is so to regulate that
the temperature on cable should be 800 50C. The
measuring can be effected until the fuse is blown.
Test voltage 400 V for power cables and wires
Test voltage 110 V for telecommunication cables
The test shall be regarded as passed when no 3 A
fuse has blown during the test period between
20 to 180 minutes.
Non-Halogen verication
According to VDE 0482 part 267/DIN EN 50267-2-1/
IEC 60754-1 (is equivalent to DIN VDE 0472 part 815).
The corrosion test of gases caused by re is carried
out to the test materials, not of complete cable
samples. The proof of halogen is effected by
chemical analysis.
Materials with a content of:
 0,2% chlorine and
 0,1% uorine
are regarded as halogen-free.
Smoke density
According to VDE 0482 part 1034-1+2 / IEC 610341+2 / DIN EN 61034-1+2 / BS 7622 Teil 1+2
(is equivalent to DIN VDE 0472 part 816).
The test of smoke density is effected to a single
cable, laid in a horizontal position within a room of
3 meter cube. The photometrically measured
absorption of light is a measuring unit (in %) of light
transmittance for the smoke density.
The test is regarded as passed when the light absorbtion appears within 40 minutes and the following values shall be obtained for light transmission.
Cable

Transmission of Light

> 3 5 mm
> 510 mm
> 1020 mm
> 2040 mm
> 40

40%
50%
60%
60%
70%

Functionality of electric cable systems


According to DIN 4102 part 12 (system test)
DIN 4102 part 12 describes the requirements and
measurements necessary in achieving circuit integrity of a complete electric cable system in case of
re.

Cable systems
Regarded as cable systems are power cables, insulated power cables and wires, telecommunication
installation cables for telephone and data transmission and rail-distributors including their corresponding connecting devices such as the necessary ducts
and conduits, coatings and coverings, connecting
elements, supporting devices, cable trays and
clamps.
Functionality
According to DIN VDE 4102 part 12
The functionality is given, when during the test
under re no short circuit and no interruption of
current ow occure in the tested electrical cable
system.
According to this standard, the security cables are
always to be tested together with the corresponding supporting devices, clamps, holder and mounting accessories.
Note: The above dened functionality has no relationship with the continuance of insulation effect
under re conditions according to DIN VDE 0472
part 814.
Test
During this test under re a complete cable installation will be tested in a large combustion chamber,
i. e. cables and wires including clamps, supporting
devices, holders, dowels etc.
Test voltage for power cables:
Test voltage for telecommunication cables:
Current load:

380 V
110 V
3A

The combustion chamber is to be heated up


according to ETK (Standard temperature curve).
The test period is distinguished in 3 classes:
E30 for the functionality  30 minutes
E60 for the functionality  60 minutes
E90 for the functionality  90 minutes
Raise of temperature in combustion chamber:
For E30 to approx. 820C
For E60 to approx. 870C
For E90 to approx. 980C
After passing the functionality test, this will be certied with the class identication as E30, E60 or E90.
Note: At the moment the class E60, which is specied in DIN-VDE standards, is not applied for
economical and technical reasons.
G

X
X 71
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Heat-resistance classes as per VDE 0530 part 1


Class

Insulating material

Impregnation material

max. continuous
temperature

Cable type

Cotton, Synthetic and natural silk,

Polyamide bres, Paper,


Polyvinylchloride (PVC), Polyethylene (PE),
Vulkanised rubber

90C

HELUKABEL
PVC + Neoprene
cables

Cotton, Synthetic and natural silk,


Polyamide, Paper, heat-resistant
impregnated textiles, Polyester resin

Bitumous varnish Synthetic resin


varnish Insulating oil and
synthetic dielectrical uids

105C

HELUTHERM
single cores, control cables
UL + CSA-approved

(E)

Special wire enamel,


Special synthetic foils,
Compressed material with cellulose llers,
Paper and cotton tapes

Synthetic resin varnish and


Polyester resin, both with a
permissible continuous withstand temperature of > 120C

105C
(short time
operation 120C)

HELUTHERM 120

Glass bre, Micaproducts,


As under E but with a permisSpecial synthetic foils,
sible continuous withstand
Compressed materials with mineral llers temperature of > 130C

145C

HELUTHERM 145

Glass bre, Micaproducts,


Aromatic polyamides,
Impregnated glass bre braides

Resins with a permissible


continuous withstand
temperature of > 155C

155C

HELUTHERM 145

Glass bre, Micaproducts,


Aromatic polyamides, Silicone rubber,
Polyamide foils, PTFE

Silicone resins with a


permissible continuous withstand
temperature of > 180C

180C

Silicone + HELUFLON
tinned conductors

Mica, Porcelain, Glass, Quartz,


and similar re resistant materials

As under H but with a permissible continuous withstand


temperature of > 225C

> 180C

HELUFLON PTFE+FEP with


tinned or nickel plated
conductors, HELUTHERM
400/600/800/1200

Caloric load values (heat of combustion)


For designing a building the criterions of the
caloric load values are very important. The caloric
load values of the modern halogen-free cables are
reduced by corresponding additives.
The specic heating values of the non-metallic raw
materials for cables are specied to DIN 51900. The
values of the caloric load or heat of combustion for
electrical cables are given per running meter in the
following tables.
The tables are subdivided according to the different
cable designs, with halogen-free or halogenated
insulation, number of cores with different crosssections.
With these tables of the caloric load values of our
cables we will give you the possibility to accomodate
your calculations for the application of these cables.

in the case of re are used. If you use PVC cables


the total caloric load is only up to 7 kWh per m2.
Cables are according to
DIN VDE 0250 part 214 halogen-free installation cable with improved re behaviour.
DIN VDE 0266 halogen-free cables with
improved characteristics in the case of re.
DIN VDE 0815 wiring cables for telecommunication and data processing systems.

Regulations:
According to DIN VDE 108 supplement 1:

The caloric load values Hu (calculated value):


PVC-core insulation Hu
6,3 kWh/kg
PVC-sheath material Hu
5,7 kWh/kg
PVC (lower limint)
Hu
5,6 kWh/kg
H-core insulation
Hu
4,8 kWh/kg
H-sheath material
Hu
4,2 kWh/kg
PE in general Hu
12,2 kWh/kg
PP in general Hu
12,8 kWh/kg

The total caloric load of the cables are allowed


up to 14 kWh per m2 of the eld areas if only
halogen-free cables with improved characteristics

The conversion of the values:


1 MJ/m2  0,278 kWh/m2, 1 kWh/m2  3,6 MJ/m2

X 72
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Caloric load values of halogen-free


Security Cables and insulated wires
Type

NHXAF

NHXMH

dimension
n x mm2

caloric load
kWh/m

Type

1 x 0,75
1 x 1,0
1 x 1,5
1 x 2,5
1x 4
1x 6
1 x 10
1 x 16
1 x 25
1 x 35
1 x 50
1 x 70
1 x 95
2 x 1,5 re
2 x 2,5 re

0,031
0,033
0,049
0,059
0,074
0,090
0,112
0,137
0,204
0,235
0,323
0,381
0,504
0,30
0,35

N2XH

3 x 1,5
3 x 2,5
3x 4
3x 6
3 x 10

re
re
re
re
re

0,33
0,38
0,49
0,60
0,78

4 x 1,5
4 x 2,5
4x 4
4x 6
4 x 10

re
re
re
re
re

0,37
0,42
0,49
0,68
0,90

5 x 1,5
5 x 2,5
5x 4
5x 6
5 x 10

re
re
re
re
re

0,42
0,49
0,70
0,79
1,04

re
re
re
re
re

0,48
0,64
0,61
0,69
1,14

7x
7x
10 x
12 x
24 x
N2XH

1,5
2,5
1,5
1,5
1,5

1 x 2,5 re
1x
4 re
1x
6 re
1 x 10 re
1 x 16 rm
1 x 25 rm
2 x 35 rm
1 x 50 rm
1 x 70 rm
1 x 95 rm
1 x 120 rm
1 x 150 rm
1 x 185 rm
1 x 240 rm
1 x 300 rm

0,14
0,17
0,18
0,21
0,29
0,39
0,46
0,53
0,55
0,63
0,72
0,90
1,08
1,22
1,32

2x
2x
2x
2x
2x
2x
2x
2x
2x

0,45
0,50
0,59
0,67
0,81
1,19
1,53
1,79
2,13

1,5 re
2,5 re
4 re
6 re
10 re
16 rm
25 rm
35 rm
50 rm

dimension
n x mm2
3 x 1,5
3 x 2,5
3x 4
3x 6
3 x 10
3 x 16
3 x 25
3 x 35
3 x 50

re
re
re
re
re
rm
rm
rm
rm

4 x 1,5
4 x 2,5
4x 4
4x 6
4 x 10
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
4 x 95
4 x 120
4 x 150
5 x 1,5
5 x 2,5
5x 4
5x 6
5 x 10
5 x 16
5 x 25
5 x 35
5 x 50

N2XCH

re
re
re
re
re
rm
rm
rm
rm
rm
rm
rm
rm

re
re
re
re
re
rm
rm
rm
rm

caloric load
kWh/m

Type

dimension
n x mm2

BrandlastkWh/m

0,48
0,56
0,65
0,73
0,86
1,19
1,65
1,95
2,31

N2XCH

4 x 25/rm 16
4 x 35/rm 16
4 x 50/rm 25
7 x 1,5/re 1,5
7 x 2,5/re 2,5
10 x 1,5/re 2,5
10 x 2,5/re 4
12 x 1,5/re 2,5
12 x 2,5/re 4
14 x 1,5/re 2,5
14 x 2,5/re 4
19 x 1,5/re 4
19 x 2,5/re 6
24 x 1,5/re 6
24 x 2,5/re 10
30 x 1,5/re 6
30 x 2,5/re 10
40 x 1,5/re 10
40 x 2,5/re 10
1 x 2,5 re
1 x 4 re
1 x 6 re
1 x 10 re
1 x 16 rm
1 x 25 rm
1 x 35 rm
1 x 50 rm
1 x 70 rm
1 x 95 rm
1 x 120 rm
1 x 150 rm
1 x 185 rm
1 x 240 rm
1 x 300 rm

1,94
2,27
2,77
0,50
0,57
0,66
0,77
0,74
0,86
0,81
0,95
1,02
1,19
1,25
1,47
1,47
1,77
1,90
2,23
0,22
0,35
0,38
0,43
0,50
0,68
0,76
0,90
1,09
1,29
1,49
1,84
2,24
2,67
3,67

0,54
0,63
0,73
0,82
0,99
1,43
1,97
2,31
2,89
3,00
3,90
4,77
6,81
0,62
0,70
0,82
0,91
1,11
1,68
2,35
2,81
3,42

7 x 1,5 re
7 x 2,5 re
10 x 1,5 re
10 x 2,5 re
12 x 1,5 re
12 x 2,5 re
14 x 1,5 re
14 x 2,5 re
19 x 1,5 re
19 x 2,5 re
24 x 1,5 re
24 x 2,5 re
30 x 1,5 re
30 x 2,5 re
2 x 1,5/re 1,5
2 x 2,5/re 2,5
2 x 4/re 4
2 x 6/re 6
2 x 10/re 10

0,51
0,58
0,68
0,78
0,76
0,88
0,84
0,97
1,05
1,21
1,31
1,53
1,54
1,80
0,44
0,49
0,59
0,66
0,80

3 x 1,5/re 1,5
3 x 2,5/re 2,5
3 x 4/re 4
3 x 6/re 6
3 x 10/re 10
3 x 16/rm 16
3 x 25/rm 16
3 x 35/rm 16
3 x 50/rm 25

0,48
0,55
0,64
0,72
0,85
1,18
1,59
1,91
2,27

4 x 1,5/re 1,5
4 x 2,5/re 2,5
4 x 4/re 4
4 x 6/re 6
4 x 10/re 10
4 x 16/rm 16

0,54
0,62
0,72
0,82
1,00
1,37

(N)HXH-E30
orange

2 x 1,5
2 x 2,5
2x 4
2x 6
2 x 10
2 x 16
2 x 25
2 x 35

re
re
re
re
re
rm
rm
rm

0,68
0,74
0,84
0,95
1,13
1,34
1,94
2,16

3 x 1,5 re
3 x 2,5 re
3 x 4 re
3 x 6 re
3 x 10 re
3 x 16 rm
3 x 25 rm
3 x 35 rm
3 x 50 rm
3 x 70 rm
3 x 95 rm
3 x 120 rm
3 x 150 rm
3 x 185 rm
3 x 240 rm

0,72
0,79
0,90
1,03
1,23
1,47
1,92
2,47
3,03
3,90
4,76
4,63
5,67
6,94
8,84

4 x 1,5
4 x 2,5
4x 4
4x 6
4 x 10
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
4 x 95

0,85
0,94
1,07
1,22
1,46
1,74
2,57
2,96
3,72
4,85
5,83

re
re
re
re
re
rm
rm
rm
rm
rm
rm

X
X 73

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Caloric load values of halogen-free


Security Cables and insulated wires
Type

(N)HXH-E 30
orange

(N)HXCH-E 30
orange

dimension
n x mm2
4 x 120
4 x 150
4 x 185
4 x 240

caloric load
kWh/m
rm
rm
rm
rm

7,26
8,92
10,38
11,76

5 x 1,5 re
5 x 2,5 re
5 x 4 re
5 x 6 re
5 x 10 re
5 x 16 rm
5 x 25 rm

0,99
1,09
1,25
1,43
1,72
2,05
3,05

7x
7x

1,5 re
2,5 re

1,16
1,29

10 x
10 x
12 x
12 x
14 x
14 x
19 x
19 x
24 x
24 x
30 x
30 x

1,5 re
2,5 re
1,5 re
2,5 re
1,5 re
2,5 re
1,5 re
2,5 re
1,5 re
2,5 re
1,5 re
2,5 re

1,47
1,63
1,84
2,05
2,09
2,42
2,52
2,79
3,30
3,66
3,77
4,19

2 x 1,5/ 1,5
2 x 2,5/ 2,5
2x 4 / 4
2x 6 / 6
2 x 10 /10

re
re
re
re
re

0,58
0,64
0,75
0,85
1,00

3 x 1,5/ 1,5
3 x 2,5/ 2,5
3x 4 / 4
3x 6 / 6
3 x 10 / 10
3 x 16 / 16
3 x 25 / 16
3 x 35 / 16
3 x 50 / 25
3 x 70 / 35
3 x 95 / 50
3 x 120 / 70
3 x 150 / 70
3 x 185 / 95
3 x 240 /120

re
re
re
re
re
re
rm
rm
rm
rm
rm
rm
rm
rm
rm

0,63
0,71
0,84
0,95
1,12
1,35
2,09
2,74
3,04
3,90
4,62
5,66
7,19
8,71
10,57

4 x 1,5/ 1,5 re
4 x 2,5/ 2,5 re
4 x 4 / 4 re
4 x 6 / 6 re
4 x 10 / 10 re
4 x 16 / 16 rm
4 x 25 / 16 rm
4 x 35 / 16 rm
4 x 50 / 25 rm
4 x 70 / 35 rm
4 x 95 / 50 rm
4 x 120 / 70 rm
4 x 150 / 70 rm
4 x 185 / 95 rm
4 X 240 /120 rm

0,78
0,82
0,96
1,09
1,30
1,56
2,40
2,74
3,50
4,49
5,35
6,51
8,35
10,13
12,32

Type

dimension
n x mm2

(N)HXCH-E 30 7 x
orange
7x
7x
10 x
10 x
10 x
12 x
12 x
12 x
16 x
16 x
21 x
21 x
24 x
24 x
30 x
30 x
40 x
40 x
(N)HXH-E 90
orange

caloric load
kWh/m

1,5/ 2,5
2,5/ 2,5
4 / 4
1,5/ 2,5
2,5/ 4
4 / 6
1,5/ 2,5
2,5/ 4
4 / 6
1,5/ 4
2,5/ 6
1,5/ 6
2,5/ 6
1,5/ 6
2,5/10
1,5/ 6
2,5/10
1,5/10
2,5/10

re
re
re
re
re
re
re
re
re
re
re
re
re
re
re
re
re
re
re

1,04
1,33
1,49
1,55
1,71
1,92
1,72
1,90
2,14
2,22
2,41
2,58
2,74
2,80
3,19
3,26
3,69
4,17
4,68

3 x 1,5 re
3 x 2,5 re
3 x 4 re
3 x 6 re
3 x 10 re
3 x 16 rm
3 x 25 rm
3 x 35 rm
3 x 50 rm
3 x 70 rm
3 x 95 rm
3 x 120 rm
3 x 150 rm
3 x 185 rm
3 x 240 rm

0,55
0,61
0,67
0,85
0,99
1,23
1,60
1,83
2,30
3,03
3,98
4,70
5,63
6,95
8,44

4 x 1,5 re
4 x 2,5 re
4 x 4 re
4 x 6 re
4 x 10 re
4 x 16 rm
4 x 25 rm
4 x 35 rm
4 x 50 rm
4 x 70 rm
4 x 95 rm
4 x 120 rm
4 x 150 rm
4 x 185 rm

0,67
0,73
0,82
0,91
1,06
1,49
1,95
2,30
2,88
3,80
4,96
5,74
6,97
8,58

5x
5x
5x
5x
5x
5x
5x
5x
7x

1,5 re
2,5 re
4 re
6 re
10 re
16 rm
25 rm
35 rm
1,5 re

0,79
0,88
0,99
1,10
1,29
1,59
2,42
2,84
0,92

1,5
1,5
1,5
1,5
1,5

1,25
1,40
1,96
2,47
2,69

10 x
12 x
19 x
24 x
27 x

re
re
re
re
re

Type

dimension
n x mm2

caloric load
kWh/m

(N)HXCH-E 90 3 x 1,5/re 1,5


0,86
orange
3 x 2,5/re
0,95
3 x 4 /re 4
1,06
3 x 6 /re
1,17
3 x 10 /re 10
1,36
3 x 16 /rm 16
1,68
3 x 25 /rm 16
2,18
3 x 35 /rm 16
2,53
3 x 50 /rm 25
3,19
3 x 70 /rm 35
4,04
3 x 95 /rm 50
4,73
3 x 120 /rm 70
5,69
3 x 150 /rm 70
6,80
3 x 185 /rm 95
8,44
3 x 240 /rm 120 10,04
4 x 1,5/ 1,5
4 x 2,5/ 2,5
4x 4 / 4
4x 6 / 6
4 x 10 / 10
4 x 16 / 16
4 x 25 / 16
4 x 35 / 16
4 x 50 / 25
4 x 70 / 35
4 x 95 / 50
4 x 120 / 70
4 x 150 / 70
4 x 185 / 95
4 x 240 /120

re 0,99
re 1,08
re 1,22
re 1,36
re 1,58
rm 1,96
rm 2,60
rm 3,11
rm 3,81
rm 4,92
rm 6,02
rm 6,90
rm 8,39
rm 10,20
rm 13,00

7 x 1,5/1,5
10 x 1,5/2,5
12 x 1,5/2,5
16 x 1,5/4
21 x 1,5/6
24 x 1,5/6

1,29
1,71
1,86
2,26
2,74
3,42

3 x 35/16
3 x 50/16
3 x 70/16
3 x 95/16
3 x 120/16

10,56
11,67
12,78
14,72
16,12

NA2XSEY 6/10 kV 3 x 35/16

10,28
11,67
13,06
14,72
16,68

NYSEY 6/10 kV

3 x 50/16
3 x 70/16
3 x 95/16
3 x 120/16

X 74
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Caloric load values of halogen-free


Security Cables and insulated wires
Type

NHXHX
black

dimension
n x mm2

caloric load
kWh/m

Type

dimension
n x mm2

caloric load
kWh/m

Type

1 x 2,5
1x 4
1x
6
1 x 10
1 x 16
1 x 25
1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
1 x 150

0,22
0,28
0,28
0,28
0,39
0,53
0,58
0,69
0,81
1,03
1,14
1,39

NHXHX
black

37 x
37 x
37 x

1,5
2,5
4

3,92
4,69
5,53

(N)HMH-O/J

HXSLHXOE

0,69
0,78
0,89
1,00
1,19

3x
3x
3x
3x

0,75
1,0
1,5
2,5

0,29
0,30
0,33
0,47

4x
4x
4x
4x

0,75
1,0
1,5
2,5

0,34
0,35
0,38
0,54

3 x 1,5
3 x 2,5
3x 4
3x 6
3 x 10
3 x 16
3 x 25
3 x 35
3 x 50
3 x 70
3 x 95
3 x 120
3 x 150

0,78
0,86
1,00
1,08
1,28
1,53
2,25
2,56
3,19
3,94
5,14
5,89
7,25

0,78
1,00
1,11
1,33
1,58
1,58
2,31
2,31
2,61
2,61
3,33
3,33
4,11
4,11
5,33
5,33
6,11
6,11
7,50
7,50

0,45
0,52
0,77
0,89
1,15
1,67
2,40
0,55
0,68

2 x 1,5
2 x 2,5
2x 4
2x 6
2 x 10

3 x 1,5/ 1,5
3x 4 / 4
3x 6 / 6
3 x 10 / 10
3 x 16 / 10
3 x 16 / 16
3 x 25 / 16
3 x 25 / 25
3 x 35 / 16
3 x 35 / 35
3 x 50 / 25
3 x 50 / 50
3 x 70 / 35
3 x 70 / 70
3 x 95 / 50
3 x 95 / 95
3 x 120 / 70
3 x 120 /120
3 x 150 / 70
3 x 150 /150

5 x 1,5
5 x 2,5
5x 4
5x 6
5 x 10
5 x 16
5 x 25
7 x 1,5
7 x 2,5

5x
5x
5x
5x

0,75
1,0
1,5
2,5

0,39
0,40
0,47
0,63

4 x 1,5
4 x 2,5
4x 4
4x 6
4 x 10
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
4 x 95
4 x 120
4 x 150

0,89
1,00
1,14
1,28
1,50
1,86
2,64
3,00
3,92
4,81
6,25
7,14
7,14

4 x 1,5/ 1,5
4 x 2,5/ 2,5
4x 4 / 4
4x 6 / 6
4 x 10 /10
4 x 16 /16
4 x 25 /16
4 x 35 /16
4 x 50 /25
4 x 70 /35
4 x 95 /50
4 x 120 /70
4 x 150 /70

0,89
1,03
1,17
1,31
1,53
1,89
2,69
3,06
4,00
4,89
6,44
7,36
8,97

1 x 1,5
1 x 2,5
1x 4
1x 6
1 x 10
1 x 16

0,16
0,19
0,23
0,26
0,33
0,41

7x
7x
7x
7x
12 x
12 x
12 x
12 x
16 x
16 x
16 x
16 x
19 x
19 x
19 x
19 x
24 x
24 x
24 x
24 x

0,75
1,0
1,5
2,5
0,75
1,0
1,5
2,5
0,75
1,0
1,5
2,5
0,75
1,0
1,5
2,5
0,75
1,0
1,5
2,5

0,48
0,50
0,54
0,72
0,77
0,80
0,88
1,37
1,02
1,06
1,15
1,65
1,26
1,32
1,43
2,02
1,50
1,57
1,70
2,42

5 x 1,5
5 x 2,5
5x 4
5x 6
5 x 10
5 x 16
5 x 25

1,03
1,14
1,31
1,47
1,83
2,17
3,14

2 x 1,5
2 x 2,5
2x 4
2x 6
2 x 10

0,30
0,34
0,43
0,51
0,74

7x
7x
7x

1,5
2,5
4

1,17
1,31
1,50

3 x 1,5
3 x 2,5
3x 4
3x 6
3 x 10

0,33
0,40
0,52
0,64
0,87

12 x
12 x
12 x
19 x
19 x
19 x
24 x
24 x
24 x

1,5
2,5
4
1,5
2,5
4
1,5
2,5
4

1,69
2,00
2,31
2,36
2,69
3,14
2,86
3,28
3,97

4x
4x
4x
4x
4x
4x
4x
4x

0,41
0,48
0,67
0,77
1,02
1,37
1,98
2,35

NHXCHX
black

(N)HMH-O/J

1,5
2,5
4
6
10
16
25
35

dimension
n x mm2

caloric load
kWh/m

X
X 75
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Caloric load values of halogenated


Cables and insulated wires
Type

dimension
n x mm2

caloric load
kWh/m

Type

NYY

1 x 2,5
1x 4
1x
6
1 x 10
1 x 16
1 x 25
1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
1 x 150

0,22
0,33
0,33
0,33
0,42
0,58
0,67
0,81
0,92
1,17
1,31
1,58

NYCY,
NYCWY

2 x 1,5
2 x 2,5
2x 4
2x 6
2 x 10

0,69
0,78
1,00
1,11
1,31

3 x 1,5
3 x 2,5
3x 4
3x 6
3 x 10
3 x 16
3 x 25
3 x 35
3 x 50
3 x 70
3 x 95
3 x 120
3 x 150

0,75
0,83
1,08
1,22
1,42
1,69
2,14
2,47
2,60
3,08
4,06
4,47
5,42

4 x 1,5
4 x 2,5
4x 4
4x 6
4 x 10
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
4 x 95
4 x 120
4 x 150

0,83
0,94
1,25
1,42
1,67
2,03
2,89
2,61
3,31
4,08
5,11
5,69
6,97

5 x 1,5
5 x 2,5
5x 4
5x 6
5 x 10
5 x 16
5 x 25

0,94
1,08
1,44
1,64
2,00
2,39
3,42

7x
7x
7x
12 x
12 x
12 x
19 x
19 x
19 x
24 x
24 x
24 x
37 x
37 x
37 x

1,5
2,5
4
1,5
2,5
4
1,5
2,5
4
1,5
2,5
4
1,5
2,5
4

1,08
1,22
1,67
1,56
1,78
2,53
2,06
2,44
3,42
2,56
2,94
4,33
3,39
4,00
6,03

A-2Y(L)2Y Bd

dimension
n x mm2

caloric load
kWh/m

3 x 1,5/ 1,5
3 x 2,5/ 2,5
3x 4 / 4
3x 6 / 6
3 x 10 / 10
3 x 16 / 10
3 x 16 / 16
3 x 25 / 16
3 x 25 / 25
3 x 35 / 16
3 x 35 / 35
3 x 50 / 25
3 x 50 / 50
3 x 70 / 35
3 x 70 / 70
3 x 95 / 50
3 x 95 / 95
3 x 120 / 70
3 x 120 /120
3 x 150 / 70
3 x 150 /150

0,78
0,86
1,11
1,25
1,47
1,75
1,75
2,53
2,53
2,22
2,22
2,78
2,78
3,28
3,28
4,28
4,28
4,72
4,72
5,72
5,72

4 x 1,5/
4 x 2,5/
4x 4 /
4x 6 /
4 x 10 /
4 x 16 /
4 x 25 /
4 x 35 /
4 x 50 /
4 x 70 /
4 x 95 /
4 x 120 /
4 x 150 /

0,86
0,97
1,28
1,44
1,69
2,08
2,92
2,67
3,44
4,17
5,33
5,94
7,22

1,5
2,5
4
6
10
16
16
16
25
35
50
70
70

2 x 2 x 0,6
4 x 2 x 0,6
6 x 2 x 0,6
10 x 2 x 0,6
20 x 2 x 0,6
30 x 2 x 0,6
40 x 2 x 0,6
50 x 2 x 0,6
100 x 2 x 0,6
150 x 2 x 0,6
200 x 2 x 0,6
250 x 2 x 0,6
300 x 2 x 0,6
350 x 2 x 0,6
400 x 2 x 0,6
500 x 2 x 0,6
600 x 2 x 0,6
700 x 2 x 0,6
800 x 2 x 0,6
1000 x 2 x 0,6

0,84
1,17
1,25
1,38
1,92
2,32
2,62
3,02
4,71
6,17
7,69
8,88
10,20
11,88
13,19
15,45
18,57
20,82
24,18
28,33

Type

dimension
n x mm2

caloric load
kWh/m

NYM

1 x 1,5
1 x 2,5
1x 4
1x 6
1 x 10
1 x 16
1 x 25

0,17
0,22
0,25
0,28
0,36
0,42
0,58

2 x 1,5
2 x 2,5
2x 4
2x 6
2 x 10

0,42
0,53
0,67
0,75
1,17

3x
3x
3x
3x
3x
3x
3x
3x

1,5
2,5
4
6
10
16
25
35

0,44
0,58
0,72
0,92
1,28
1,53
2,39
2,78

4x
4x
4x
4x
4x
4x
4x
4x

1,5
2,5
4
6
10
16
25
35

0,53
0,67
0,92
1,08
1,50
1,86
2,89
3,28

5 x 1,5
5 x 2,5
5x 4
5x 6
5 x 10
5 x 16
5 x 25

0,58
0,75
1,11
1,28
1,83
2,31
3,42

6x

1,5

0,67

7x

1,5

0,67

X 76
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Caloric load values of halogen-free and


halogenated Cables and insulated wires
Type

dimension
n x mm2

caloric load
kWh/m

Type

dimension
n x mm2

caloric load
kWh/m

Type

dimension
n x mm2

caloric load
kWh/m

JE-H (St) H Bd

2 x 2 x 0,6
4 x 2 x 0,6
6 x 2 x 0,6
10 x 2 x 0,6
20 x 2 x 0,6
30 x 2 x 0,6
40 x 2 x 0,6
50 x 2 x 0,6
60 x 2 x 0,6
80 x 2 x 0,6
100 x 2 x 0,6

0,12
0,18
0,23
0,33
0,64
0,81
1,05
1,34
1,50
2,01
2,53

J-HH Bd

2 x 2 x 0,8
4 x 2 x 0,8
8 x 2 x 0,8
12 x 2 x 0,8
20 x 2 x 0,8
32 x 2 x 0,8
40 x 2 x 0,8

0,28
0,39
0,58
0,86
1,17
1,78
2,08

0,22
0,33
0,39
0,53
0,81
0,97
1,11
1,36
1,72
2,00
2,39
3,06
3,72

J-YY Bd

JE-H (St) H Bd

2 x 2 x 0,6
4 x 2 x 0,6
6 x 2 x 0,6
10 x 2 x 0,6
16 x 2 x 0,6
20 x 2 x 0,6
24 x 2 x 0,6
30 x 2 x 0,6
40 x 2 x 0,6
50 x 2 x 0,6
60 x 2 x 0,6
80 x 2 x 0,6
100 x 2 x 0,6

2 x 2 x 0,6
4 x 2 x 0,6
6 x 2 x 0,6
10 x 2 x 0,6
16 x 2 x 0,6
20 x 2 x 0,6
24 x 2 x 0,6
30 x 2 x 0,6
40 x 2 x 0,6
50 x 2 x 0,6
60 x 2 x 0,6
80 x 2 x 0,6
100 x 2 x 0,6

0,11
0,17
0,22
0,28
0,39
0,44
0,50
0,67
0,81
0,94
1,17
1,42
1,69

0,28
0,45
0,78
1,08
1,36
1,64

J-Y(St)Y,
JE-Y(St)Y

2 x 2 x 0,6
4 x 2 x 0,6
6 x 2 x 0,6
10 x 2 x 0,6
20 x 2 x 0,6
30 x 2 x 0,6
40 x 2 x 0,6
50 x 2 x 0,6
60 x 2 x 0,6
80 x 2 x 0,6
100 x 2 x 0,6

0,12
0,18
0,23
0,33
0,72
0,81
1,05
1,34
1,50
2,01
2,53

2 x 2 x 0,8
4 x 2 x 0,8
6 x 2 x 0,8
10 x 2 x 0,8
20 x 2 x 0,8
30 x 2 x 0,8
40 x 2 x 0,8
50 x 2 x 0,8
60 x 2 x 0,8
80 x 2 x 0,8
100 x 2 x 0,8

0,16
0,29
0,35
0,55
1,21
1,36
1,67
2,19
2,44
3,18
4,07

1 x 2 x 0,6
2 x 2 x 0,6
3 x 2 x 0,6
4 x 2 x 0,6
5 x 2 x 0,6
6 x 2 x 0,6
8 x 2 x 0,6
10 x 2 x 0,6
12 x 2 x 0,6
14 x 2 x 0,6
16 x 2 x 0,6
20 x 2 x 0,6
24 x 2 x 0,6
30 x 2 x 0,6
40 x 2 x 0,6
50 x 2 x 0,6
60 x 2 x 0,6
80 x 2 x 0,6
100 x 2 x 0,6

0,15
0,17
0,20
0,23
0,26
0,28
0,29
0,33
0,38
0,40
0,43
0,47
0,52
0,69
0,77
0,92
1,20
1,41
1,83

J-Y(St)Y,
JE-Y(St)Y

1 x 2 x 0,8
2 x 2 x 0,8
3 x 2 x 0,8
4 x 2 x 0,8
5 x 2 x 0,8
6 x 2 x 0,8
8 x 2 x 0,8
10 x 2 x 0,8
12 x 2 x 0,8
14 x 2 x 0,8
16 x 2 x 0,8
20 x 2 x 0,8
24 x 2 x 0,8
30 x 2 x 0,8
40 x 2 x 0,8
50 x 2 x 0,8
60 x 2 x 0,8
80 x 2 x 0,8
100 x 2 x 0,8

0,19
0,25
0,31
0,38
0,43
0,50
0,56
0,75
0,81
0,87
1,00
1,13
1,45
1,70
2,08
2,65
2,84
3,92
4,94

J-H(St)H Bd

J-H (St) H Bd

J-HLiHCH Bd

2 x 2 x 0,5 mm2
4 x 2 x 0,5 mm2
8 x 2 x 0,5 mm2
12 x 2 x 0,5 mm2
20 x 2 x 0,5 mm2
32 x 2 x 0,5 mm2
40 x 2 x 0,5 mm2

1,0
1,4
2,1
3,1
4,2
6,4
7,5

J-H (St) H Bd
2 x 2 x 0,8
E 30 bis E 90
4 x 2 x 0,8
red
8 x 2 x 0,8
Fire warning 12 x 2 x 0,8
installation
16 x 2 x 0,8
cable
20 x 2 x 0,8
32 x 2 x 0,8
40 x 2 x 0,8
52 x 2 x 0,8

0,20
0,34
0,72
0,89
1,08
1,36
2,03
2,59
3,06

J-H (St) HRH Bd 2 x 2 x 0,8


E 30 bis E 90
4 x 2 x 0,8
red
8 x 2 x 0,8
Fire warning 12 x 2 x 0,8
installation
16 x 2 x 0,8
cable
20 x 2 x 0,8
32 x 2 x 0,8
40 x 2 x 0,8
52 x 2 x 0,8

0,39
0,66
1,27
1,56
1,81
2,26
3,23
4,15
4,68

JE-LiHH Bd

I-YY Bd

JE-Y (St) Y Bd

4 x 1 x 0,5 mm2
8 x 1 x 0,5 mm2
16 x 1 x 0,5 mm2
24 x 1 x 0,5 mm2
32 x 1 x 0,5 mm2
40 x 1 x 0,5 mm2
2 x 2 x 0,6
4 x 2 x 0,6
6 x 2 x 0,6
10 x 2 x 0,6
16 x 2 x 0,6
20 x 2 x 0,6
24 x 2 x 0,6
30 x 2 x 0,6
40 x 2 x 0,6
50 x 2 x 0,6
60 x 2 x 0,6
80 x 2 x 0,6
100 x 2 x 0,6

0,11
0,17
0,22
0,28
0,39
0,44
0,50
0,67
0,81
0,94
1,17
1,42
1,69

2 x 2 x 0,8
4 x 2 x 0,8
8 x 2 x 0,8
12 x 2 x 0,8
16 x 2 x 0,8
20 x 2 x 0,8
24 x 2 x 0,8
28 x 2 x 0,8
32 x 2 x 0,8
36 x 2 x 0,8
40 x 2 x 0,8
44 x 2 x 0,8
48 x 2 x 0,8
52 x 2 x 0,8
56 x 2 x 0,8
60 x 2 x 0,8
64 x 2 x 0,8
68 x 2 x 0,8
72 x 2 x 0,8
76 x 2 x 0,8
80 x 2 x 0,8

0,19
0,28
0,42
0,58
0,72
0,83
0,94
1,17
1,28
1,39
1,50
1,61
1,83
1,94
2,06
2,14
2,25
2,36
2,47
2,72
2,83

X
X 77

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Caloric load values of halogen-free


Security Cables and insulated wires
Type

dimension
n x mm2

caloric load
kWh/m

Type

dimension
n x mm2

caloric load
kWh/m

Type

HELUTHERM 1 x 0,25
145
1 x 0,33
1 x 0,50
1 x 0,75
1 x 1,0
1 x 1,5
1 x 2,5
1x 4
1x 6
1 x 10
1 x 16
1 x 25
1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
1 x 150
1 x 185
1 x 240

0,00884
0,00973
0,01231
0,01600
0,01958
0,02931
0,04157
0,05014
0,05952
0,10655
0,13120
0,21506
0,25086
0,33443
0,40502
0,53553
0,61629
0,77025
0,94133
1,18313

HELUTHERM 1 x
MULTI 145
2x
3x
4x
5x
6x
7x
8x
10 x
12 x
14 x
16 x
19 x
21 x
24 x
25 x
27 x
30 x
33 x
37 x

HELUTHERM 1 x
MULTI 145
2x
3x
4x
5x
6x
7x
8x
10 x
12 x
14 x
16 x
19 x
21 x
24 x
25 x
27 x
30 x
33 x
37 x

0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50

0,04
0,08
0,09
0,11
0,14
0,16
0,19
0,24
0,27
0,25
0,28
0,32
0,41
0,45
0,48
0,48
0,46
0,51
0,57
0,68

1x
2x
3x
4x
5x
6x
7x
8x
10 x
12 x
14 x
16 x
19 x
21 x
24 x
25 x
27 x
30 x
33 x
37 x

0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75

0,05
0,09
0,11
0,13
0,17
0,20
0,22
0,29
0,32
0,30
0,34
0,38
0,48
0,54
0,59
0,58
0,55
0,61
0,66
0,85

dimension
n x mm2

caloric load
kWh/m

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

0,05
0,11
0,13
0,16
0,19
0,23
0,29
0,34
0,38
0,35
0,40
0,44
0,59
0,66
0,70
0,69
0,66
0,70
0,83
1,03

HELUTHERM 1 x
MULTI 145
2x
3x
4x
5x
6x
7x
8x
10 x
12 x
14 x

4
4
4
4
4
4
4
4
4
4
4

0,10
0,29
0,27
0,35
0,45
0,54
0,68
0,80
0,90
0,81
0,94

1x
2x
3x
4x
5x
6x
7x

6
6
6
6
6
6
6

0,16
0,46
0,52
0,57
0,71
0,88
1,02

1x
2x
3x
4x
5x
6x
7x
8x
10 x
12 x
14 x
16 x
19 x
21 x
24 x
25 x
27 x
30 x
33 x
37 x

1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5

0,06
0,14
0,16
0,20
0,25
0,32
0,38
0,47
0,51
0,46
0,52
0,60
0,83
0,92
1,01
0,98
0,93
1,00
1,12
1,37

1 x 10
2 x 10
3 x 10
4 x 10
5 x 10
6 x 10
7 x 10

0,15
0,53
0,58
0,74
0,87
1,00
1,25

1 x 16
2 x 16
3 x 16
4 x 16
5 x 16
6 x 16
7 x 16

0,17
0,64
0,73
0,89
1,07
1,23
1,58

1x
2x
3x
4x
5x
6x
7x
8x
10 x
12 x
14 x
16 x
19 x
21 x
24 x
25 x
27 x
30 x
33 x
37 x

2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5

0,07
0,17
0,21
0,27
0,34
0,41
0,51
0,63
0,65
0,59
0,72
0,80
1,04
1,24
1,32
1,29
1,22
1,31
1,47
1,88

1 x 25
2 x 25
3 x 25
4 x 25
5 x 25
6 x 25
7 x 25

0,24
1,01
1,08
1,30
1,64
2,04
2,46

1 x 35
2 x 35
3 x 35
4 x 35
5 x 35

0,29
1,28
1,32
1,64
2,04

1 x 50
2 x 50
3 x 50
4 x 50
5 x 50

0,36
1,76
1,81
2,15
2,53

1 x 70
2 x 70
3 x 70
4 x 70
5 x 70

0,42
2,28
2,25
2,77
3,36

1 x 95
2 x 95
3 x 95
4 x 95
5 x 95

0,55
2,72
2,81
3,42
4,11

X 78
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Caloric load values of halogen-free


Security Cables and insulated wires
Type

dimension
n x mm2

caloric load
kWh/m

Type

dimension
n x mm2

caloric load
kWh/m

HELUKABEL
MULTI-C 145

1x
2x
3x
4x
5x
6x
7x
8x
10 x
12 x
14 x
16 x
19 x
21 x

0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50
0,50

0,05
0,12
0,12
0,15
0,18
0,21
0,24
0,27
0,31
0,30
0,35
0,39
0,48
0,54

HELUKABEL
MULTI-C 145

1x
2x
3x
4x
5x
6x
7x
8x
10 x
12 x
14 x
16 x
19 x
21 x

2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5

0,11
0,29
0,32
0,36
0,45
0,55
0,69
0,82
0,87
0,83
1,01
1,17
1,47
1,61

1x
2x
3x
4x
5x
6x
7x
8x
10 x
12 x
14 x
16 x
19 x
21 x

0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75

0,05
0,14
0,15
0,18
0,21
0,25
0,31
0,35
0,39
0,38
0,43
0,49
0,62
0,69

1x
2x
3x
4x
5x
6x
7x
8x
10 x
12 x
14 x
16 x

4
4
4
4
4
4
4
4
4
4
4
4

0,13
0,36
0,39
0,49
0,56
0,66
0,84
1,04
1,16
1,10
1,23
1,42

1x
2x
3x
4x
5x
6x
7x
8x
10 x
12 x
14 x
16 x
19 x
21 x

1
1
1
1
1
1
1
1
1
1
1
1
1
1

0,07
0,16
0,17
0,20
0,24
0,30
0,36
0,41
0,46
0,44
0,50
0,57
0,74
0,82

1x
2x
3x
4x
5x
6x
7x

6
6
6
6
6
6
6

0,15
0,43
0,48
0,60
0,71
0,82
1,06

1 x 10
2 x 10
3 x 10
4 x 10
5 x 10
6 x 10
7 x 10

0,22
0,67
0,77
0,99
1,21
1,41
1,68

1 x 16

0,28

1x
2x
3x
4x
5x
6x
7x
8x
10 x
12 x
14 x
16 x
19 x
21 x
24 x
25 x
27 x
30 x
33 x
36 x
37 x

1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5

0,08
0,22
0,21
0,28
0,33
0,41
0,48
0,58
0,66
0,63
0,72
0,80
1,08
1,19
1,32
1,30
1,27
1,37
1,53
1,71
1,85

1 x 25

0,35

X
X 79
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Information and Installation Instructions


for UL and CSA cables
UL/CSA cables must be protected against
mechanical, thermal and chemical damages.
Installation in switchboards and control
boards
Inside switchboards, exible single core cables
must be installed in cable channels of plastics
As american cables are not so exible, the minimum bending radius must be taken into consideration during exible installation.
For connections on machinery and equipment
Permissible tube and conduit :
minimum- = 1/2 (inch)
maximum- = 4 (inch)
Minimum wall-thickness of the conduit = 1,9 mm
Normal steel armoured tubes with transition
socket PG-NPT is used. Further metal cable
channels must also be used.
The cables are permitted to be lled with only
max. 50% cross-section of the cable channel.
Flexible single cores must be installed in PVC
tubes inside the conduits.
If connectors are used, both the main and the
control cables should be installed separately.
Delivery program:
PVC tubes
Metal tubes and glands
Fixing material
Steel armoured tubes.
Cable Channels
Cable channels in switchboards must be made
out of a ame resistant PVC and must have
enough spare space.
Cable channels on machineries and equipment
must be made out of metal. They must also be
closed and oil resistant.
Cable identication
Cable identication is achieved through continuous numbers, letters or number/letter combination. The beginning and end of the cable have
the same identication system.

Cable connections to apparatus


Main and Control cables
It is depending on the type of connection to the
apparatus if screw or press clamps are used.
In USA, it is normal to install cables without using
cable lugs or cable crushing socket. The connection is only possible with the UL-wires sizes. These
sizes are not designed with ne wire stranding
make-up.
Conductor cross-section
General rules
Motor Cables
Control Cables
in switchboards
in the installed system

minimum
cross-section for
AWG 14
AWG 18
AWG 16

This rule does not apply to electronic devices and


systems.
In case, the electronic cables and other circuits are
installed together, all cables must be set for
maximum voltage.
Colour identication
Black
For main circuits, control- and subcircuits, direct
connected to main voltage.
Blue
For direct voltage- (d. c.), control- and subcircuits,
which are connected to the main circuit.
Red
For alternating voltage (a. c.), control and
subcircuits.
Yellow or brown
For interlock circuits from an external power
source.
White or grey
For current conveying earthed conductors at
main, control and subcircuits.
Green or green-yellow
For insulated earth-connectors as protective
conductor.
Motor-driving voltages
200 / 230 / 460 / 575 V, 60 Hz
Driving voltage
Normally the driving voltage is 120 V, 60 Hz or lower.
Transformers must be operated with separate
windings.

X 80
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

AWG-Wires and AWG-stranded conductors


Conductor make-up, cross-section, resistance and weight
AWG
No.

AWGmake-up
n x AWG

conductor
make-up
mm

crosssection
mm2

conductor
outer-
mm

conductor
resistance
Ohm/km

conductor
weight
kg/km

36
36

solid
7/44

solid
7 x 0,05

0,013
0,014

0,127
0,152

1460,0
1271,0

0,116
0,125

34
34

solid
7/42

solid
7 x 0,064

0,020
0,022

0,160
0,192

918,0
777,0

0,178
0,196

32
32
32

solid
7/40
19/44

solid
7 x 0,078
19 x 0,05

0,032
0,034
0,037

0,203
0,203
0,229

571,0
538,0
448,0

0,284
0,302
0,329

30
30
30

solid
7/38
19/42

solid
7 x 0,102
19 x 0,064

0,051
0,057
0,061

0,254
0,305
0,305

365,0
339,0
286,7

0,45
0,507
0,543

28
28
28

solid
7/36
19/40

solid
7 x 0,127
19 x 0,078

0,080
0,087
0,091

0,330
0,381
0,406

232,0
213,0
186,0

0,71
0,774
0,81

27

7/35

7 x 0,142

0,111

0,457

179,0

0,988

26
26
26
26

solid
10/36
19/38
7/34

solid
10 x 0,127
19 x 0,102
7 x 0,160

0,128
0,127
0,155
0,141

0,409
0,533
0,508
0,483

143,0
137,0
113,0
122,0

1,14
1,13
1,38
1,25

24
24
24
24
24

solid
7/32
10/34
19/36
41/40

solid
7 x 0,203
10 x 0,160
19 x 0,127
41 x 0,078

0,205
0,227
0,201
0,241
0,196

0,511
0,610
0,582
0,610
0,582

89,4
76,4
85,6
69,2
84,0

1,82
2,02
1,79
2,14
1,74

22
22
22
22

solid
7/30
19/34
26/36

solid
7 x 0,254
19 x 0,160
26 x 0,127

0,324
0,355
0,382
0,330

0,643
0,762
0,787
0,762

55,3
48,4
45,1
52,3

2,88
3,16
3,4
2,94

20
20
20
20
20
20

solid
7/28
10/30
19/32
26/34
41/36

solid
7 x 0,320
10 x 0,254
19 x 0,203
26 x 0,160
41 x 0,127

0,519
0,562
0,507
0,615
0,523
0,520

0,813
0,965
0,889
0,940
0,914
0,914

34,6
33,8
33,9
28,3
33,0
32,9

4,61
5,0
4,51
5,47
4,65
4,63

18
18
18
18
18
18

solid
7/26
16/30
19/30
41/34
65/36

solid
7 x 0,404
16 x 0,254
19 x 0,254
41 x 0,160
65 x 0,127

0,823
0,897
0,811
0,963
0,824
0,823

1,020
1,219
1,194
1,245
1,194
1,194

21,8
19,2
21,3
17,9
20,9
21,0

7,32
7,98
7,22
8,57
7,33
7,32

16
16
16
16
16
16

solid
7/24
65/34
26/30
19/29
105/36

solid
7 x 0,511
65 x 0,160
26 x 0,254
19 x 0,287
105 x 0,127

1,310
1,440
1,310
1,317
1,229
1,330

1,290
1,524
1,499
1,499
1,473
1,499

13,7
12,0
13,2
13,1
14,0
13,1

11,66
12,81
11,65
11,72
10,94
11,84

14
14
14
14
14

solid
7/22
19/27
41/30
105/34

solid
7 x 0,643
19 x 0,361
41 x 0,254
105 x 0,160

2,080
2,238
1,945
2,078
2,111

1,630
1,854
1,854
1,854
1,854

8,6
7,6
8,9
8,3
8,2

18,51
19,92
17,31
18,49
18,79
Continuation 

X
X 81
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

AWG-Wires and AWG-stranded conductors


Conductor make-up, cross-section, resistance and weight
AWG
No.

AWGmake-up
n x AWG

conductor
make-up
mm

12
12
12
12
12

solid
7/20
19/25
65/30
165/34

solid
7 x 0,813
19 x 0,455
65 x 0,254
165 x 0,160

10
10
10
10

solid
37/26
49/27
105/30

8
8
8

crosssection
mm2

conductor
outer-
mm

conductor
resistance
Ohm/km

conductor
weight
kg/km

3,31
3,63
3,09
3,292
3,316

2,05
2,438
2,369
2,413
2,413

5,4
4,8
5,6
5,7
5,2

29,46
32,30
27,50
29,29
29,51

solid
37 x 0,404
49 x 0,363
105 x 0,254

5,26
4,74
5,068
5,317

2,59
2,921
2,946
2,946

3,4
3,6
3,6
3,2

46,81
42,18
45,10
47,32

49/25
133/29
655/36

49 x 0,455
133 x 0,287
655 x 0,127

7,963
8,604
8,297

3,734
3,734
3,734

2,2
2,0
2,0

70,87
76,57
73,84

6
6
6

133/27
259/30
1050/36

133 x 0,363
259 x 0,254
1050 x 0,127

13,764
13,123
13,316

4,676
4,674
4,674

1,5
1,3
1,3

122,49
116,79
118,51

4
4
4

133/25
259/27
1666/36

133 x 0,455
259 x 0,363
1666 x 0,127

21,625
26,804
21,104

5,898
5,898
5,898

0,80
0,66
0,82

192,46
238,55
187,82

2
2
2
2

133/23
259/26
665/30
2646/36

133 x 0,574
259 x 0,404
665 x 0,254
2646 x 0,127

34,416
33,201
33,696
33,518

7,417
7,417
7,417
7,417

0,50
0,52
0,52
0,52

306,30
295,49
299,89
298,31

1
1
1
1

133/22
259/25
817/30
2109/34

133 x 0,643
259 x 0,455
817 x 0,254
2109 x 0,160

43,187
42,112
41,397
42,403

8,331
8,331
8,331
8,331

0,40
0,41
0,42
0,41

384,37
374,80
368,43
377,39

1/0
1/0

133/21
259/24

133 x 0,724
259 x 0,511

54,75
53,116

9,347
9,347

0,31
0,32

487,28
472,73

2/0
2/0

133/20
259/23

133 x 0,813
259 x 0,574

69,043
67,021

10,516
10,516

0,25
0,25

614,48
596,49

3/0
3/0

259/22
427/24

259 x 0,643
427 x 0,511

84,102
87,570

11,786
11,786

0,20
0,19

748,51
779,37

4/0
4/0

259/21
427/23

259 x 0,724
427 x 0,574

106,626
110,494

13,259
13,259

0,16
0,15

948,97
983,39

AWG-Wires (Solid-conductor)
AWG
No.
44
41
40
39
38
37
36
35
34
33
32
31
30
29

Wire-
mm
0,050
0,070
0,079
0,089
0,102
0,114
0,127
0,142
0,160
0,180
0,203
0,226
0,254
0,287

AWG
No.
28
27
26
25
24
23
22
21
20
19
18
17
16
15

Wire-
mm
0,320
0,363
0,404
0,455
0,511
0,574
0,643
0,724
0,813
0,912
1,024
1,151
1,290
1,450

AWG
No.
14
13
12
11
10
9
8
7
6
5
4
3
2
1

Wire-
mm
1,628
1,829
2,052
2,304
2,588
2,906
3,268
3,665
4,115
4,620
5,189
5,827
6,543
7,348

AWG
No.
1/0
2/0
3/0
4/0

Wire-
mm
8,252
9,266
10,404
11,684

X 82
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

US-American and British units


Conversion of usual measuring units
Units for cables and wires
In the US the measurements are mainly used in AWG-numbers (AWG = American Wire Gauge).
The AWG-numbers conform the british B&S-numbers (B&S = Brown & Sharp)
AWG
No.

Crosssection
mm2

Diameter
mm

Conductor
resistance
Ohm/km

AWG
No.

Crosssection
mm2

Diameter
mm

Conductor
resistance
Ohm/km

1000 MCM*
750
600
500
400
350
300
250
4/0
3/0
2/0
0
1
2
3
4
5
6
7
8
9
10
11
12
13

507
380
304
254
203
178
152
127
107,20
85,00
67,50
53,40
42,40
33,60
26,70
21,20
16,80
13,30
10,60
8,366
6,63
5,26
4,15
3,30
2,62

25,4
22,0
19,7
20,7
18,9
17,3
16,0
14,6
11,68
10,40
9,27
8,25
7,35
6,54
5,83
5,19
4,62
4,11
3,67
3,26
2,91
2,59
2,30
2,05
1,83

0,035
0,047
0,059
0,07
0,09
0,10
0,12
0,14
0,18
0,23
0,29
0,37
0,47
0,57
0,71
0,91
1,12
1,44
1,78
2,36
2,77
3,64
4,44
5,41
7,02

14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39

2,08
1,65
1,31
1,04
0,8230
0,6530
0,5190
0,4120
0,3250
0,2590
0,2050
0,1630
0,1280
0,1020
0,0804
0,0646
0,0503
0,0400
0,0320
0,0252
0,0200
0,0161
0,0123
0,0100
0,00795
0,00632

1,63
1,45
1,29
1,15
1,0240
0,9120
0,8120
0,7230
0,6440
0,5730
0,5110
0,4550
0,4050
0,3610
0,3210
0,2860
0,2550
0,2270
0,2020
0,1800
0,1600
0,1430
0,1270
0,1130
0,1010
0,0897

8,79
11,20
14,70
17,80
23,0
28,3
34,5
44,0
54,8
70,1
89,2
111,0
146,0
176,0
232,0
282,0
350,0
446,0
578,0
710,0
899,0
1125,0
1426,0
1800,0
2255,0
2860,0

4/0 is also stated: 0000; 1 mil = 0,001 inch = 0,0254 mm


* for bigger cross-section the sizes in MCM (circular mils)

1 CM = 1 Circ. mil. = 0,0005067 mm2


1 MCM = 1000 Circ. mils = 0,5067 mm2

General measuring units


Length
1 mil
1 in (inch)
1 ft (foot)
1 yd (yard)
1 ch (chain)
1 mile (land mile)
1 mile (nautic mile)
1 mm
1m
Area
1 CM (circ. mil)
1 MCM
1 sq. inch (sq. inch)
1 sq. ft. (sq. foot)
1 square yard
1 acre
1 square mile
Density
1 cu. in. (cubic inch)
1 cu. ft. (cubic foot)
1 cu. yd. (cubic yard)
1 gal. (US gallon)
1 gal. (brit gallon)
1 US pint
1 US quart
1 US barrel
Temperature
F (Fahrenheit)
C (Celsius)
Weight
1 grain
1 dram

= 0,0254 mm
= 25,4 mm
= 0,3048 m
= 0,9144 m
= 20,1 m
= 1,609 km
= 1760 yards
= 1,852 km
= 0,039370 inches
= 39,370079 inches
= 0,507 103 mm2
= 0,5067 mm2
= 645,16 mm2
= 0,0929 m2
= 0,836 m2
= 4047 m2
= 2,59 km2
= 16,39 cm3
= 0,0283 m3
= 0,7646 m3
= 3,785 l
= 4,546 l
= 0,473 l
= 0,946 l
= 158,8 l
= (1,8 C) + 3
= 0,5556 (F32)
= 64,8 mg
= 1,77 g

1 oz (ounce)
= 28,35 g
1 lb (pound)
= 0,4536 Kp
1 stone
= 6,35 Kp
1 qu (quarter)
= 12,7 Kp
1 US-cwt (hundredweight)
= 45,36 Kp
1 US ton (short ton) = 0,907 t
1 brit. ton (long ton) = 1,016 t
Force
1 lb
= 4,448 N
1 brit. ton
= 9954 N
1 pdl (Poundal)
= 0,1383 N
1 kp
= 9,81 N
1N
= 0,102 kp
Velocity
1 mile/h
= 1,609 km/h
1 Knoten
= 1,852 km/h
1 ft/s
= 0,305 m/s
1 ft/min
= 5,08 103 m/s
Energy
1 lb/mile
= 0,282 kg/m
1 lb/yard
= 0,496 kg/m
1 lb/foot
= 1,488 kg/m
Radiation absorbed dose
1 Gray
= 1 J/kg
1 rad
= 10 2J/kg = 1 Centi Gy
= 0,01 Gy
1 Centi
= 100 Joule
1 rad
= cJ/kg = 0,01Gy
1 Mrad
= 1 106 cJ/kg
Pressure
1 psi (lb/sq.)
= 68,95 mbar
= 6,895 103 Nmm2

1 lb/sq. ft.
1 pdl/sq. ft.
1 in Hg
1 ft H2 O
1 in H2 O
1 N/mm2
1 kp/mm2
1 at
1 Torr
1 bar
1 Pa
Density
1 lb/cu. ft.
1 lb/cu. in.
Horse power
1 hp h

= 0,478 mbar
= 1,489 N/m2
= 33,86 mbar
= 29,89 mbar
= 2,491 mbar
= 145 psi
= 10 bar
= 1422 psi
= 736 Torr
= 1 kp/cm2
= 1 mm Hg
= 0,1 H Pa
= 1 N/m2
= 16,02 kg/m3
= 27,68 t/m3

= 1,0139 PS h
= 2,684 106 Joule
= 746 W h
1 BTU (brit. therm. unit) = 1055 Joule
Electrical units
1 ohm/1000 yd
= 1,0936 /km
1 ohm/1000 ft
= 3,28 /km
1 F/mile
= 0,62 F/km
1 megohm/mile
= 1,61 M/km
1 f/foot
= 3,28 pF/m
1 decibel/mile
= 71,5 mN/m
Power rate
1 PS
= 0,736 kW
1 kW
= 1,36 PS
1 hp
= 0,7457 kW
1 kW
= 1,31 hp

X 83
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Current ratings for UL-CSA cables


Ambient temperature 30 C
Abstract of NEC Tabelle 310-17
Allowable ampacity (in Ampere) of conductors, rated 0 2000 Volts,
in free air.

Conductor
size

Temperature Rating of Conductor

Abstract of NEC Tabelle 310-16


Allowable ampacity (in Ampere) of insulated conductors, rated 0
2000 Volts. NOT MORE THAN three Conductors in raceway or
cable ore Earth (direct burial).
Conductor
size

Temperature Rating of Conductor

AWG or
kcmil (MCM)

60 C
(140 F)

75 C
(167 F)

90 C
(194 F)

AWG or
kcmil (MCM)

60 C
(140 F)

75 C
(167 F)

90 C
(194 F)

18

18

18

14

16

24

16

18

14

25

30

35

14*

20

20

25

12

30

35

40

12*

25

25

30

10

40

50

55

10*

30

35

40

60

70

80

40

50

55

80

95

105

55

65

75

105

125

140

70

85

95

120

145

165

85

100

110

140

170

190

95

115

130

165

195

220

110

130

150

1/0

195

230

260

1/0

125

150

170

2/0

225

265

300

2/0

145

175

195

3/0

260

310

350

3/0

165

200

225

4/0

300

360

405

4/0

195

230

260

250

340

405

455

250

215

255

290

300

375

445

505

300

240

285

320

350

420

505

570

350

260

310

350

400

455

545

615

400

280

355

380

500

515

620

700

500

320

380

430

600

575

690

780

600

355

420

475

* Note Unless otherwise specically permitted elsewhere in the NEC, the overcurrent protection for conductor types market with an * shall not exceed
15 amperes for AWG 14, 20 amperes for AWG 12 and 30 amperes for AWG 10, after any correction factors for ambient temperature and numbers of
conductros have been applied.

Correction factors for ambient temperatures


other than 30 C

Correction factors for more than three currentcarrying conductors in a raceway or cable.

Ambient
temperature in C

60 C
(140 F)

75 C
(167 F)

90 C
(194 F)

Number of current-carrying
conductors

Correction factor

21 25

1,08

1,05

1,04

4 up to 6

0,80

26 30

1,00

1,00

1,00

7 up to 9

0,70

31 35

0,91

0,94

0,96

10 up to 20

0,50

36 40

0,82

0,88

0,91

21 up to 30

0,45

41 45

0,71

0,82

0,87

31 up to 40

0,40

46 50

0,58

0,75

0,82

41 and more

0,35

51 55

0,41

0,67

0,76

56 60

0,58

0,71

61 70

0,33

0,58

71 80

0,41

X 84
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

List of UL-Styles
UL-Style
No.

Insulation
Material

Voltage

Temp.
C

Volt
1001
1002
1003
1004
1005
1006
1007
1011
1013
1015
1017
1019
1020
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1037
1039
1040
1041
1043
1045
1049
1053
1054
1055
1056
1060
1061
1063
1095
1096
1098
1099
1107
1108
1109
1110
1113
1115
1116
1118
1119
1120
1122
1123
1124
1158
1159
1160
1161
1162
1164
1180
1181
1185
1195
1198
1199
1206
1208
1227
1228
1229
1230
1231
1232
1233
1235
1237
1239
1270
1271
1272
1279
1280
1283
1284
1287
1306
1308

PVC/Nylon
PVC
PE, FRPE
PVC/Nylon
PVC/Nylon
PVC/Nylon
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC/Nylon
PVC
PVC
PVC
PVC/Nylon
PVC
PVC/Nylon
PVC
PVC/Nylon
PVC
PVC
P/B
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
SR PVC
PVC
PVC
PVC/Nylon
PE
PVC
PE, FRPE
PVC
PVC, XPVC
PVC; XPVC
PE
PVC
PVC/Nylon
PVC
PVC
PVC
SR PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PTFE
PTFE
PVC/Nylon
PVC
PVC
PTFE
PTFE
PVC
PVC
FEP
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC

* not specied

300
600
300

300
600
600
600
600
600
600
600
600
600
600
600
600
600
600
1000
1000
1000
1000
300
300
300
300
300
300
300
600
600
600
600
600
300
300
300
300
2000
300
300
300
300
300
600
300/600
600
300
600
600
300
300
300
300
300
300
600
600
300
300
600
300
300
600
600
300
300
not specied*
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600

80
60
60
80
90
105
80
80
90
105
80
80
80
80
80
90
90
90
90
105
105
80
80
90
90
60
80
80
60
80
90
80
60
80
90
105
105
80
60
80
80
60
80
60
80
90
105
60
80
80
90
90
105
80
80
80
60
60
60
60
60
150
200
60
80
80
150
200
80
80
105
90
90
105
105
105
80
105
80
105
90
90
90
80
80
105
105
105
80
105

(single core cables)

Insulation
thickness
mm

AWG
Size

0,23
0,76
0,76
0,20
0,20
0,20
0,38
0,76
0,76
0,76
1,14
1,52
2,05
2,78
3,17
1,14
1,14
1,52
1,91
1,14
1,14
0,76
0,76
0,76
0,76
0,30
0,38

0,76
0,76
0,76
1,14
1,52
1,52
1,52
1,52
1,91
0,23

0,30

0,86
0,38
0,38

0,38
0,38

0,38

0,38
0,76
0,76
0,23
0,76
0,76
0,76
1,14
0,38
0,76
1,14
0,33
0,38
0,76
0,38
0,38
0,51
0,51
0,33
0,33
0,20
1,14
1,52
0,76
1,14
1,52/2,03
1,52
1,52
1,14
1,14
1,14
1,52
1,91
1,52
1,14
1,52
1,91
1,91
2,29
2,29

30 16
26 16
26 16
30 16
26 16
26 16
32 16
28 9
28 9
28 9
22 8
8 2
1 4/0

18 8
8 6
8 6
1 4/0
22 8
8 6
26 10
26 10
26 10
26 10
24 20
22 16
22 16
20 16
20 16
20 16
20 16
18 10
18 10
20 10
20 10
10 10
30 16
20 18
30 16
26 10
18
28
30 16
26 16
26 16
26 16
26 16
30 16
22 8
26 16
26 16
30 4/0
30
22 20
22 20
22 9
8
22 16
22 9
22 9
32 10
28 10
18 16
30 4/0
26 14
26 10
26 10
30 16
26 16
32 14
18 8
8 2
26 8
18 8
8 4/0
18 8
18 8
22 19
22 19
18 9
8 2
1 4/0
7 2
18 8
8 2
1 4/0
18 12
8
8

UL-Style
No.
1316
1317
1318
1319
1320
1321
1322
1327
1329
1330
1331
1332
1333
1335
1336
1337
1338
1366
1394
1400
1401
1402
1405
1408
1409
1410
1411
1412
1413
1414
1429
1430
1435
1436
1437
1438
1439
1444
1452
1453
1498
1499
1500
1508
1517
1523
1533
1536
1538
1542
1546
1558
1568
1569
1570
1575
1581
1586
1591
1592
1605
1609
1610
1612
1618
1624
1662
1680
1683
1692
17107
1708
1722
1729
1792
1847
1848
1860
1888
1908
1909
1926
1948
1967
1968
1986
1990
1999
10009
10011
10030
10032
10050

Insulation
Material
PVC/Nylon
PVC/Nylon
PVC/Nylon
PVC/Nylon
PVC/Nylon
PVC/Nylon
PVC
PVDF
PVC
FEP
FEP
FEP
FEP
PVC
PVC
PVC
PVC
PVC/PVC
PTFE
PVC
PVC
PVC/Nylon
PVC/Nylon
PVC/Nylon
PVC/Nylon
PVC/Nylon
PVC/Nylon
PVC/Nylon
PVC/Nylon
PVC/Nylon
XPVC
XPVC
PE
PE
PE
PE
PE
PVC
PVC/Nylon
PVC/Nylon
PCV
PVC
PVC
ETFE
ETFE
ETFE
PVC
XPVC
FEP
PE-PVC
PE-PVC
ETFE
PVC
PVC
ETFE
PVC
PVC
ETFE
FEP
FEP
PVC
ETFE
ETFE
PVDF
PVC
PVC
PVC
PVC
PVC
PVC
PFA
PFA
TPR
PVC
PE, PVC
FEP
FEP
PFA
TPR
PVC
PVC
PE o. FRPE
PVC
PVC
PVC
FEP
ETFE
Zell. FEP
Zell. FEP
PFA
PFA
PFA
FEP

Insulation
thickness
mm

AWG
Size

Volt

Voltage

Temp.
C

600
105
600
105
600
105
600
105
600
105
600
105
600
90

105
600
105
600
200
600
105
300
200
300
150
600
90
600
90
600
90
600
90
600
90

200
600
90
600
90
600
90
600
90
600
90
600
90
600
90
600
90
600
90
600
90
600
90
150
80
300
105
300
80
300
80
300
80
300
80
300
80
1000
90
1000
90
1000
90
600
80
600
90
600
105
30
105

105

105

80

80
125
105
10000
80
600

125
150
80
300
105
600
250
48
60
300
80

105
300
150
300
200
30
60
125
105
not specied** 105
125
150
300
80
160
80
300
80

105

80
30
80
30
200
not specied** 200
600
125
300
80
30
80
30
105
300
150 o. 200
150
200
300
125
300
80
600
80
300
60+80
60
60
30
60+80

60+80
30
80
600
105
300
150
300
150
30
80
300
250
600
250
600
150

0,38
0,51
0,76
1,02
1,27
1,78
1,91
0,25
1,91
variable
variable
0,38
0,38
0,76
1,14
1,52
1,98
variable
0,15
1,14
1,52
0,76
1,98
0,38
0,51
0,76
1,02
1,27
1,52
1,78
0,25
0,38
0,41
0,79
1,63
1,14
0,81
1,14
0,38
0,51
0,76
0,76
0,76
0,15
0,15
0,13
0,23
0,25
0,15

0,10
0,23
0,38

0,76
0,38
0,20
0,41
0,41
0,10
0,13
0,25

0,38
0,25
variable

2,54
0,127
0,127
VAR
0,22
0,05
0,08
0,38
0,25
0,41
0,38
0,76
0,17
0,10
0,38
0,38
0,05
0,50
0,45
0,45
0,0254
0,025
0,38
0,457

26 12
10
8 6
4 2
1 4/10
250 1000
14 10
30 16
14 10
30 4/0
30 4/0
30 10
30 10
22 10
8
6 2
8 4/0
26 9
32 20
14 10
8
22 10
1 4/10
22 12
10
8 6
4 2
1 4/10
250 500
600 1000
32 16
30 16
26 16
26 16
26 16
26 16
26 16
18 10
18 12
10
22 9
22 9
22 9
32 20
32 20
32 20
30 10
30 10
32 20
24 10
20
32 20
30 16
28 10
24 8
18 8
14
32 6
26 16
26 16
min. 46
32 6
32 10

30 16
18 1/10
18 1/10
3/0
min. 42
32 20
32 20
22 4/0
32 16
min. 40
min. 40
min. 24
32 16

26 4/0
26 4/0
30 16
min. 46
20 4/0
20 4/0
min. 50
30 4/0
min. 36
min. 36
min. 40
30 10
30 10
30 4/0

X 85
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

List of UL-Styles
UL-Style
No.

Insulation
Material

Voltage

Temp.
C

Insulation
thickness
mm

AWG
Size

80
90
80
80
80
90
105
60
60
60
60
60
60
90
80
80
90
90
90
105
105
105
60
60
60
80
80
80
80
80
80
90
90
90
90
90
90
105
105
105
105
105
60

1,14
1,14
1,52
1,52
1,91
1,91
1,91

0,38

0,38

0,38
0,38
0,38

0,38
0,38
0,38
0,76
0,76
0,76
0,76
0,76
0,76
1,14
0,76
0,76

20 16
20 16
18 16
18 16
14 10
14 10
14 10
20 18
20 18
20 18
26 16
26 16
26 16
32 16
30 16
30 18
26 16
26 16
26 16
30 16
30 16
30 16
26 12
26 12
26 12
26 16
26 16
26 16
26 16
26 16
26 16
26 16
26 16
26 16
28 9
28 9
28 9
28 9
29 9
28 9
20 16
18
26 16

60

0,76

26 16

60

0,76

26 16

0,38

as for SVT
as for SVT
as for SVT
as for SVT
as for SVT
as for SVT
as for SVT
as for SVT
as for SVT
as for SVT

26 16
26 16
36 30
26 16
26 16
26 16
26 16
26 16
26 16
26 16
26 16
26 16
26 16
26 16
26 16
26 16
26 16
26 16
26 16
26 16
26 16
26 16

30
30
30
30

30 16
26 16
30
26 16

26 10

Volt
2006
2007
2012
2015
2030
2031
2032
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2106
2107
2108
2112
2113
2114
2115
2116
2117
2121
2122
2123
2124
2125
2126
2127
2128
2129
2243
2261
2262

PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PE
PE
PE
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PE
PE
PE
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PE

2263

PE

2264

PE

2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2317
2351
2352
2353
2354
2355
2376
2384
2385
2386
2387
2388
2405
2439
2448
2461
2462
2463

PVC
PVC
PVC
PVC
PVC
PVC
as for SVT
as for SVT
as for SVT
as for SVT
as for SVT
as for SVT
as for SVT
as for SVT
as for SVT
as for SVT
PE
PE
PE
PE
PE
PE
PVC
variable
VAR
VAR
VAR
PVC
PVC
PE
variable
PVC
PVC
PVC

300
300
300
300
600
600
600
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
600
600
600
300
300
300
600
600
600
300/600
300/600
300/600
600
600
600
600
600
600
300
300
600 (isol.)
300 (Jacket)
600 (isol.)
300 (Jacket)
600 (isol.)
300 (Jacket)
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
600
600
300
300
600
600
300
30
30
30
30
30
300
600
30
30
300
600

(Multicore cables)

80
80
80
80
80
80
60
60
60
60
60
60
60
60
60
60
60
80
80
80
80
80
105
60
60
60
60
60
80
80
60
60
60
80

UL-Style
No.

Insulation
Material

Voltage

Temp.
C

Insulation
thickness
mm

300
600
30
600
600
600
300
30
30
300
300
600
30
30
125
600
600

30
150
150
125
600
600
30

80
80
105
60
105
60
60
60
80
105
80
105
60
105
105
60
80
80
90
90
105
60
75
60
80
80
105
80
60
80
105
90
105

0,38

AWM

AWM
AWM

AWM

AWM

300
300
300

60
60
80

Volt
2464
2468
2474
2477
2483
2489
2490
2493
2498
2501
2502
2504
2507
2516
2517
2532
2535
2548
2549
2550
2551
2560
2564
2567
2570
2571
2574
2576
2582
2584
2586
2587
2589

variable
PVC
PVC
PVC
PVC
PVC
AWM
PP
PE
PVC
variable
PVC
PVC
PVC
PVC
PVC
PVC
PE
PVC
AWM
AWM
PVC
PVC
PVC
PVC
PVC
AWM
PVC
PE
PVC
PVC
PVC
AWM

2598
2606
2610

VAR
PE
labeled Style
1007
AWM
PE
AWM
PE
AWM
AWM
AWM
AWM
AWM
PVC
AWM
AWM
AWM
PVC
AWM
PVC
PVC
AWM
AWM
AWM
PP
PP
AWM
AWM
AWM
AWM
AWM
S/GB
S/GB
XLPE
XLPE
SiR
SiR
SiR
SiR
XLPE
XLPE
XLPE
XLPE
XPVC
PE
PE
AWM

2614
2623
2626
2629
2630
2631
2637
2653
2654
2655
2656
2660
2661
2662
2668
2678
2704
2778
2789
2833
2835
2919
2920
2921
2930
2931
2937
3071
3075
3173
3199
3212
3213
3214
3239
3265
3266
3271
3272
3291
20063
20083
20601

300
300
600
600
600
not specied*

30
30
30
300
125
not specied*
30
600
300
300
600
not specied*
300
600
30
30
30
150
30
30
30
30
30
30
not specied*
125
300
600
600
600
300
600
600
600
VAR
150
300
600
600
300
300
300
300

105
80
80
80
90
90
90
90
90
80
80
60
105
105
60
105
60
60
60
60
80
80
60
60
105
105
80
200
200
125
105
150
150
150
150
125
125
125
125
105
80
80
80

AWG
Size

32 16
26 16
33 16
26 16
18
min. 36
30 16
28 16
30

20 14
26 16
30 9
32 16
30 16
30 16

30 16
min. 40
min. 40
30
22

30 9
30 16
min. 40
30 9
30 16
30 9
30 9
30 9
see AWM
Requirements

30 16

30
labeled Style see 1007
Requirements
1007
AWM
min. 40

30 20
not specied*
AWM

30 16
AWM
30 9
AWM
min. 40
AWM
min. 40
AWM
36 6
AWM
36 6

33 10
AWM
36 6
AWM

AWM
36 6

33 10
AWM
min. 40

30
AWM
30 16
AWM
see AWM
AWM

22

28 18
AWM
min. 40
AWM
min. 40
AWM
min. 40
AWM
min. 40
AWM
AWM
0,76
18 14
0,76
10 2
0,76
26 9
0,38
22 16
1,14
26 10
1,52
8 2
1,91
1 4/0
VAR
24 10
0,25
28 20
0,38
26 16
VAR
24 12
VAR
22 4

26 16
0,5
28 16
AWM
various AWG
AWM
AWM

* not specied

X 86
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Index British Standard


91
125
215
801
1441
1442
1791
1843
1990
2316
2848
3242
3573
3858
3988
4066
4553
4565
4579
4653
4799
4801
4808
4927
50266
5055
5099
5308
5372
5425
5467
5593
5819
6004
6007
6116
6141
6195
6207
6231
6234
6346
6360
6387
6425
6469
6480
6485
6500
6622
6708
6724
6726
6746

Electric cables, soldering buckets


Electric conductors, copper & copper-cadmium, for overhead transmission
Electric conductors, aluminium & steel-cored aluminium
Cable sheaths, lead and lead alloy
Galvanised steel wire, for submarine cables
Galvanised steel wire, for land cables
Electric conductors, copper, cotton-covered
Insulated cables, twin compensating cables, thermocouples, colour codes
Communication transmission lines, wood poles
Coaxial cables, radio frequency
Cable sheaths, exible
Electric conductors, aluminium alloy, stranded, for power transmission
Communication cables, polyolen insulated & sheathed copper-conductor cables
Electric cables, sleeves, binding & identication
Electric conductors, aluminium solid conductors, for insulated cables
Superseded by BSEN 50266-1:2001
Insulated cables, PVC-insulated, split concentric copper
Electric conductors, steal wire for reinforcing aluminium conductors
Electric cables, mechanical & compression joints in connectors
Electric conductors, copper, paper covered
Electric conductors, copper glass bre lapped
Electric conductors, copper, glass bre braided
Communication cables, LE, PVC insulated & sheathed
Electric conductors, copper, textile covered
Test methods for cables under re conditions
Insulated cables, PVC & elastomer-insulated, for discharge-tube installations
Cable sheaths, spark testing
Insulated cables, instrumentation, intrinsically safe
Electric cables, terminations for 3 & 4 core insulated cables, dimensions
Communication cables, coaxial
Power cables, armoured thermosetting-polymer insulated, for electricity supply
Sheathed cables, aluminium-sheathed CONSAC cables
Communication cables for interconnection between video recorder and television receivers
Insulated cables, PVC insulated, non-armoured
Insulated cables, rubber-insulated, non-armoured
Flexible cables, elastomer-insulated exible trailing cables, for mines and quarries
Flexible conductors, for high temperature zones
Flexible cables, insulated, for coil leads
Mineral-insulated cables, copper sheathed, with copper conductors
Single-core cables, PVC insulated, for switchgear and controlgear
Insulated cables, polyethylene
Power cables, PVC-insulated, for electricity supply
Electric conductors, insulated cables
Electric cables, re-resistant, tests
Electric cables, combustion gases, test methods
Insulated cables, insulation and sheaths, test methods
Power cables, impregnated paper-insulated, lead or lead alloy sheathed electric cables
Electric conductors, PVC covered overhead power line conductors
Flexible cables, insulated cords and cables
Power cables, thermosetting-polymer insulated, high voltage
Flexible cables, trailing cables, mining equipment
Thermosetting polymer insulated, for electricity supply, low smoke
Flexible conductors, for festoon and temporary lighting
Cable sheaths, PVC

X
X 87
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Index British Standard


6862
6883
6899
6946
6977
7211
7365
7919
9530
4737
5425
638
6746C
Aero 2E21
Aero G177
Aero G189
Aero G192
Aero G195
Aero G206
Aero G210
Aero G212
Aero G215
Aero G221
Aero G222
Aero G227
Aero G230
Aero G231
Aero G232
Aero G233
Aero G235
Aero G236
Aero G237
Aero G238
Aero G241
Aero G242
Aero G243
Aero G291
AU231
AU237
AU7
AU88
AU88a
PD2379

Electric cables, road vehicles


Insulated cables, elastomer insulated cables, for ships
Cable sheaths, rubber
Electric cables, metal channel support systems
Multicore cables, insulated exible cables, for lifts
Power cables, thermosetting polymer insulated, non-armoured, low smoke
Electric conductors, hard drawn aluminium wire, for overhead lines
Electric cables, exible cables rated up to 450/750v for use with appliances and equipment
intended for indutrial and similar environments
Electric cables, cable tting accessories, assessed quality, for circular electrical connectors
Insulated cables, PVC-insulated, for intruder alarm systems
Coaxial cables, for wideband distribution systems
Flexible cables, arc welding
Insulated cables, PVC insulation, colour chart
Pren type electric cables, for aircraft
Insulated cables, Nyvin type for aircraft
Tersil electric cables, for aircraft, imperial units
Specication for Efglas type electric cables with copper conductors, for aircraft
Insulated cables, Minyvin type, for aircraft, imperial units
Fepsil-type cables, for aircraft
Specication for PTFE insulated equipment wires (with silver plated copper conductors)
Electric cables, for aircraft
Insulated cables, thermocouple extension cables, for aircraft
Insulated cables, Minyvin-type, for aircraft, metric units
Insulated cables, Efglas-type, for aircraft, metric units
Tersil electric cables, for aircraft, metric units
Specication for general requirements for aircraft electrical cables (second series)
Electric conductors, copper and copper alloy, for aircraft cables
Insulated cables, lightweight thin-wall, wrapped for aircraft
Insulated cables, lightweight thin-wall, extruded for aircraft
Insulated cables, lightweight thin-wall, wrapped, silver plated copper conductors for aircraft
Insulated cables, lightweight thin-wall, wrapped, nickel plated copper conductors for aircraft
Insulated cables, lightweight thin-wall, extruded, nickel plated copper conductors for aircraft
Insulated cables, lightweight thin-wall, wrapped, nickel plated copper conductors for aircraft
Electric cables, re-proof, for aircraft
Communication cables, for aircraft data bus interconnecting systems
Electric cables, ignition, for aircraft engines
Insulated cables, Efglas-type, for aircraft, imperial units
Specication for seven-core connecting cable for road vehicles
Flexible conductors, jumper lead sets, for automotive starting
Electric cables, automotive, colour codes
Electric cables, automobile, light duty, ratings
Recommendations for ratings for light duty cables for automobile use
Electric cables, manufacturers identication threads, Commonwealth, South Africa, colour
register

X 88
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

International abbreviations
Association Franaise de NORmalisation
(France)
ANSI
American National Standards Institute
(USA)
AS
Australian Standard (Australia)
ASTM
American Standard of Testing Materials
(USA)
BS
British Standard (Great Britain)
BSI
British Standard Institution (Great Britain)
BV
Bureau Veritas (France)
CATV
Community Antenna Television
(International)
CEBEC
Comit Electrotechnique Belge (Belgium)
CEE
International Commission on Ruls for the
Approval of Electrical Equipment
(International Commission)
CEI
Commission Electrotechnique Internationale (International)
CEMP
Centre dEtude des Matires Plastiques
(France)
CEN
Comit Europen de Normalisation Electrotechniques
CENELEC Comit Europen de Normalisation Electrotechniques
CNET
Centre National dEtude de Tlcommunication (France)
CNOMO Comit de Normalisation des Moyens de
Production
CSA
Canadian Standards Association (Canada)
CSTB
Centre Scientique et Technique du
Btiment (France)
DEMKO Danmarks Elektriske Materielkontrol
(Denmark)
DIN
Deutsches Institut fr Normung
(Germany)
DKE
Deutsche Elektrotechnische Kommission
im DIN und VDE (Germany)
EN
European Standards (Germany)
FAR
Federal Air Regulation (USA)
FTZ
Fernmeldetechnisches Zentralamt
(Germany)
GOST
USSR-Standards
HD
Harmonisierungs-Dokumente (International)
HN
Harmonisation des Normes (France)
IEC
International Electrotechnical Commission
(International)
IEE
Institution of Electrical Engineers
(Great Britain)
AFNOR

IEEE
ISDN
ISO
KEMA
LCIE
MIL
NEC
NEMA
NEMKO
NEN
NF
NFC
VE
SAE
SEK
SEMKO
SETI
SEV
SNV
TGL

UL
UNI
UTE
VDE
VDEW
ZVEH
ZVEI

Institute of Electrical and Electronics


Engineers
Integrated Services Digital Network
(International)
International Organization for Standardization (International)
Keuring van Elektrotechnische Materialien
(Netherlands)
Laboratoire Central des Industries Electriques (France)
Military Specication (USA)
National Electrical Code (USA)
National Electrical Manufacturers Association (USA)
Norges Elektriske Materiellkontroll
(Norway)
Nederlands Normalisatie-Instituut
(Netherlands)
Normes Franaises (France)
Normes Franaises Class C (France)
sterreichischer Verband fr Elektrotechnik (Austria)
Society of Automotive Engineers
Svenska Elektriska Kommissionen
(Sweden)
Svenska Elektriska Materielkontrollanstalten (Sweden)
Shktarkastuslatios (Finland)
Schweizerischer Elektrotechnischer Verein
(Swizerland)
Schweizerischer Normenverband
(Swizerland)
DDR-Standards: Technische Normen,
Gtevorschriften und Lieferbedingungen
(ehemalige GDR)
Underwriters Laboratories Inc. (USA)
Unicazione Nationale Italiana (Italy)
Union Technique de lElectricit
(France)
Verein Deutscher Elektroingenieure
(Germany)
Vereinigung Deutscher Elektrizittswerke
e. V. (Germany)
Zentralverband der Deutschen Elektrohandwerke e. V. (Germany)
Zentralverband der Elektrotechnik- und
Elektronik Industrie e. V. (Germany)

X
X 89
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Characteristics* of insulating and sheath materials


Designation
VDE
Initialcode

Thermoplastic

Yw

Abbreviations

PVC

PVC

Materials

Electrical
Density

Breakdownvoltage-

g/m3

Spezic
volume
resistivty
Ohm cm
KV/mm (20C) 20C

Polyvinylchloride
compounds

1,351,5

25

Heat-resistant
90C

1,31,5

25

10131015

10121015

Dielectric
constant

Thermic
Dielectric
lossfactor
tan

50 Hz/20C
3,66

46,5
4 x 10-2
to
1 x 10-1

+100

20
+ 90

+120

20
+105

+120

>140

40
+ 70

+100

>140

(% O2)

MJ kg-1
1725

>140

10121015

4,56,5

Yk

PVC

Cold resistant

1,21,4

25

10121015

4,5 6,5

2Y

LDPE

Low density
Polyethylene

0,920,94 70

1017

2,3

2 x 104

50
+ 70

+100

105110

2Y

HDPE High density


Polyethylene

0,940,98 85

1017

2,3

3 x 104

50
+100

+120

130

2X

VPE

Cross-linked
Polyethylene

0,92

50

10121016

46

2 x 103

35
+ 90

+100

Foamed
Polyethylene

0,65

30

1017

1,55

5 x 104

40
+ 70

+100

105

Polystrole

1,05

30

1016

2,5

1 x 104

50
+ 80

+100

>120

PS

Heating value
H0

2342

25

3Y

Oxygen
index
LOI

>140

1,31,5

1622
self-extinguishing

2442

1620

1724

22
42-44

1830

22

4043

22

2731

ammable

4Y

PA

Polyamide

1,02 1,1

30

1015

2 x 102 bis 60
+105
1 x 103

+125

210

9Y

PP

Polypropylene

0,91

75

1016

2,3 2,4

4 x 104

10
+ 90

+140

160

11Y

PUR

Polyurethane

1,15 1,2

20

1010 1012

47

2,3 x 102

55
+ 80

+100

150

2026

2026

Polyester
Elastomer

1,2 1,4

40

>1010

3,7 5,1
1,8 x 10

TPE-O

Elastomere

30
+ 70

Heat-resistant
105C

O2Y

Flameresistance

+C

PVC

High temp. materials

permanent short time


C
C

Melttemperrature

Yw

TPE-E
(12Y)

halogen-free
compouns

Working temperature

Polyolene
Elastomer

0,891,0

30

>1014

2,73,6

4244

+140

190

29

2025

50
+100

+130

150

25

2328

65
+ 60

+120

ammable

22

2125

high ash
point

2535

1719

NR
SBR

Natural rubber
Styrol-butadienerubber-compounds

1,51,7

20

10121015

35

1,9 x 102

2G

SiR

Silicone rubber

1,2 1,3

20

1015

34

6 x 103

60
+180

+260

3G

EPR

Ethylen-propylene
rubber-compounds

1,31,55

20

1014

33,8

3,4 x 103

30
+ 90

+160

4G

EVA

Ethylen-vinylacetat
copolymer-compunds

1,31,5

30

1012

56,5

2 x 102

30
+125

+200

5G

CR

Polychloroprene
compounds

1,41,65

20

1010

68,5

5 x 102

40
+100

+140

2125
ammable

3035

1012

69

2,8 x 102

30
+ 80

+140

+160

1,71,9

25

1014

97

1,4 x 102

40
+135

+160

>170

self-extinguishing

4045

15

Ethylene-Tetrauor
ethylene

1,61,8

36

1016

2,6

8 x 104

100
+150

+180

>265

self-extinguishing

3035

14

FEP

Fluorine ethylene
propylene

2,02,3

25

1018

2,1

3 x 104

100
+205

+230

>225

self-extinguishing

>95

PFA

Peruoralkoxypolimeric

2,02,3

25

1018

2,1

3 x 104

190
+260

+280

>290

self-extinguishing

>95

20

18

2,1

190
+260

+300

self-extinguishing

>95

10Y

PVDF Polyvinylidene uoride


Kynar/Dyor

7Y

ETFE

6Y

5YX

HX

1419
self-extinguishing

25

CSM

1923

1,31,6

6G

5Y

22

PTFE

Chlorsulfonated
Polyethylene compunds

Polytetrauorethylene

not
halogen-free
crosspolymer-compounds
linked
cross- halogen-free
linked polymer-compounds

2,02,3

10

3 x 10

>325

1923

1,41,6

25

10121014

3,45

103

30
+ 70

+100

>130

self-extinguishing

40

17-22

1,41,6

25

10131014

3,45

102103

30
+ 90

+150

self-extinguishing

40

1625

=
* The characteristics valid for unprocessed material

X 90
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Characteristics* of insulating and sheath materials

Hydrogen
chloride

N/mm2

Shorehardness

Corrosion
behaviour

Halogen
Abrasion
resistance

halogenfree

Weather
Weather
resistance

Cold
resistance

Abbreviat
ions

Material

PVC

Polyvinylchloridecompounds

Yw

PVC Heat-resistant
90C

Yw

PVC Heat-resistant
105C

YK

PVC

2Y

LDPE Low density


Polyethylene

2Y

HDPE High density


Polyethylene

good

2X

VPE

O2Y

moderategood
80

1025

130350

7095 (A)

medium

0,4

no
medium
in black
very good

0,3

0,4

1020

400600

4350 (D)

medium

2030

5001000

6063 (D)

good
0,1

no

300400

4045 (D)

medium

0,25

812

350450

5565

300400

3550 (D)

good

0,4

5060

50170

very good

1,01,5

2035

300

5560 (D)

medium

0,1

100 (500)

3045

500700

70100 (A) very good

0,5

10

30

1,5

10

20

100

0,22

50

80

0,23

conditional1)

medium good

yes

0,25

no

Cross-linked
Polyethylene
Foamed
Polyethylene

3Y

PS

Polystrole

4Y

PA

Polyamide

9Y

PP

Polypropylene

11Y

PUR

Polyurethane

good

1,5

moderate
yes2)

85 (A)
70 (D)
>300

very good
good

1,5

very good

6070 (A)

510

TPE-E
(12Y)

Polyester
Elastomer

TPE-O

Polyolene
Elastomer

yes

55 (A)
70 (D)

no

NR
SBR

Natural rubber
Styrol-butadienerubber-compounds

good

2G

SiR

Silicone rubber

very good

3G

EPR

Ethylen-Propylene
rubber-compounds

4G

EVA

Ethylen-vinylacetat
copolymer-compunds

moderate good

5G

CR

Polychloroprene
compounds

moderate

6G

CSM

Chlorsulfonated
Polyethylene compunds

moderate

300600

very good
4080 (A)
moderate

no

moderate good

good

10
0,19

Cold resistant

good
12,520

no

yes

100

0,3

0,25

Designation
VDEInitialcode

200

200400

6585 (A)
1,0

yes
good

100

812

50

1020

Hydrogen
chloride

250350

7080 (A)

400700

5570 (A

good

medium
350600

6070 (A)

no

very good

1,5

0,17

Hydrouoric

10

5080

150

7580 (D)

very good

0,01

very good

very good

10Y

PVDF Polyvinylidene uoride


Kynar/Dyor

0,24

yes

10

4050

150

7075 (D)

very good

0,02

very good

very good

7Y

ETFE Ethylene-Tetrauor
ethylene

0,26

yes

1525

250

5560 (D)

very good

0,01

very good

very good

6Y

FEP

Fluorine ethylene
propylene

0,21

yes

0,1

2530

250

5560 (D)

very good

0,01

very good

very good

5YX

PFA

Peruoralkoxypolimeric

0,26

yes

0,1

80

50

5560 (D)

very good

0,01

very good

very good

5Y

PTFE Polytetrauorethylene

0,17

no

100

813

150250

H
0,21,5

medium
in black:
good

not
cross- halogen-free
linked polymer-compounds

medium
6595 (A)

0,20

1)

no

200

813

150250

The propellent may be e.g. Fluor-Chlor-Hydrcarbon

no

medium

2)

yes

Elastomere

0,17

Mrad

Elongation
at break

average
HX

cross- halogen-free
linked polymer-compounds

High temp. materials

WK-1m-1

Mechanical
tensile
strength

halogen-free
compouns

Corrosive
Radiationgases in
resistancecase of re max

Thermoplastic

Thermic
Thermalconductivity

depend on the type compound

X
X 91

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Denitions: Classes of Stress (Duty) in Flexible


Cables and Insulated Wires
The application of a exible cable in certain areas as, or in, operating materials as well as for certain combinations of external inuences that can occur in these areas, is described by the collective term stress or
duty. Suitable exible cables and insulated wires are dened in the applicable equipment standards for the
devices in question. On the basis of mechanical inuences, as well the general expressions used, the term
stress or duty is divided into the following categories.
Normal stress / Ordinary duty
Normal stress is present when the cables are subject to low mechanical stresses in the areas of application, and the risk of mechanical damage is low, as is the case to be expected in the normal use of small to
medium size equipment in domestic and commercial as well as in light industrial premises.
Such equipment includes amongst others, vacuum cleaners, toasters, washing machines, refrigerators.
Low stress / Light duty
Low stress is then present when the risk of mechanical damage and mechanical stress is low in the
areas of application, as is the case to be expected for normal use of lightweight hand-held devices and
lightweight operating materials in domestic households.
Included in such equipment are radios, oor lamps, hairdryers, small desktop ofce equipment.
Very low stress / Extra light duty
Very low stress is then present when the risk of mechanical damage and mechanical stress is very low
and can be considered negligible, i.e. under those inuences that are to be expected for lightweight
appliances in households and ofces; Cases of applications where the cables having a greater mechanical
protection would restrict the freedom of movement by the appliance. Included in such types of
appliances are electric clocks and electric shavers.
High stress / Heavy duty
High stress is then present when the risk of mechanical damage or a mechanical stress is of medium
severity appreciable, e.g. for normal use of equipment in moderately heavy branches of industry or agricultural workshops, and the temporary use of such at building sites.
Included in such equipment are, amongst others, moderately heavy portable machinery and motors at a
building site or in agricultural workings, large hot-water boiling installations, hand-held lamps, hoists, and
xed installations in temporary buildings.
High stress (Heavy duty) in multi-core cables
Applications as for high stress, though primarily for use in areas of manufacturing facilities including toolmaking machinery, or mechanical handling equipment. The cables can be used inside or outside buildings for an ambient temperatures ranging from between 25C and +50C and the stabilised conductor
temperatures do not exceed +60C Examples are for connecting a control unit to a production machine,
connections between a control unit and a machine, e.g. in hoists or cranes where the cable length does
not normally exceed 10 m. Longer cable lengths are permissible for xed inter-connections.

Application: Indoor and outdoor use


The terms are in conjunction with the limiting conditions, such as for example, minimum and maximum
operating temperatures, or the inuence of the ambient temperatures, understood as being limited by the
design and intended usage. This context is dened by the intended environment.
Indoor use
The cables are installed or connected to an apparatus device and can be used permanently in the
building at all times, namely in the intended environment. The building can be used for commercial,
industrial or residential purposes.
Outdoor use for a limited period
The cables may be used outdoors as the intended environment for short periods of time, e.g.
connected to electric lawnmowers or drills.
Permanent outdoor use
The cables are designed to resist the various stresses that can occur outdoors in the intended environment (including weather conditions).
X 92
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Safety Requirements in the Use of Cables and


Insulated Wires
Fundamental requirements
The cables and insulated wires shall be of adequate safety for proper use in the intended manner such
that these do not constitute any unacceptable risk to life or damage to property. The prevention of danger
to persons and property during usage and storage of operating equipment means safety to include the
detection of stress, risk and potential faults, as well as their rectication or a limitation to a minimum risk
level.
Unless otherwise specied, cables and insulated wires should only be used for the conductance and distribution of electricity.

General requirements
The choice in the selection of cables and insulated wires should be such that the voltages and currents
prevailing in the operating equipment, a system or device used shall meet all operating conditions to be
expected.
The cables shall be constructed, installed, protected, used and maintained to prevent danger as far as its
reasonably practical.

Limiting conditions
The limiting conditions in the DIN VDE and HD specications shall be taken into account. An acceptable
service life will be attained by compliance with the limiting conditions, depending on the circuit designed
under dened conditions for use. The usable life of a permanently installed cable for power distribution is
longer than that of a exible cable.
The inuence by all of the factors given in the following sections must be considered as an interrelationship
and not on an individual basis.

Selection of cables and insulated wires


The choice in the selection of cables and insulated wires shall be made such that these are suitable for the
operating conditions as well as for all other external inuences and compliance with the respective protection class.
a) Operating conditions are, for example:
voltage
protective measures
grouping of cables
current
method of installation
accessibility
b) External inuences are, for example:
ambient temperature
presence of rain, water vapour or the accumulation of water
presence of corrosive, contaminating or other chemical substances
mechanical stresses (such as holes or sharp edges from metal constructions for example)
animal world (such as rodents)
plant world (such as fungal growths)
irradiation (such as sunlight).
Note: The colour black provides a higher degree of protection than other colours.

X
X 93
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Safety Requirements in the Use of Cables and


Insulated Wires
Requirements for cables
for permanent installation, and
for exible applications

Requirements for xed installation


In the normal case, cables for permanent installation have solid single wire or stranded conductors. In
certain circumstances, e.g. for greater ease of installation, the conductor may be Class 5 according to HD
383 or DIN VDE 0295.
Cables should not be in contact with, or close to, hot surfaces if the cables are not intended for such
conditions.
Cables should not be buried directly in the earth and should be fastened by a suitable means while making
allowance for the maximum spacing between xing points.
The cable should not be damaged by any mechanical restraint used for its support . Cables which have been
in use over longer periods of time may become damaged by movement. This can be caused by the natural
effects of ageing on the physical properties of the materials used for the insulation sheath and jacket which
can become brittle with time.

For exible applications


Flexible cables are made up conductors consisting of multiplicity of small wires and are either stranded or
bunched. These cables meet either Class 5 or Class 6 of HD 383 and DIN VDE 0295.
Flexible cables should be used for connections to mobile operating equipment. The length of the
connecting cable must be chosen such that response by the short-circuit protecting device is assured.
The cable length should be as short as is needed for the practical application so as to reduce the risk of
mechanical damage. In cases of applications where exible PVC-sheathed cables are permissible, the use of
spiral cables can be considered for shortening the effective length.
Flexible PVC-sheathed cables are not necessarily suitable for processing further to spiral cables. Multicore
control cables shall be protected against permanent bending stress. Abrasion, notches and sharp bends are
to be avoided.
Except for cables for connections to permanently installed operating equipment, exible cables should
not be permanently xed (with the exception of heavy-duty cable designs for permanent installation in
temporary facilities) unless these are contained in an enclosure affording mechanical protection. For a xed
installation, at least one cable should be used for normal stress.
Flexible cables should not be subjected to excessive straining from tensile forces, compression, twisting
or kicking. This applies in particular at the point of entry into the device, and strain relief or the point of
connection to the xed wiring. These should not be damaged by any strain relief or clamping device at
points to the permanent installation.
Flexible cables should not be placed under oorcoverings or carpets because there is the danger that this
can cause thermal insulating effects, leading to increased temperatures, or that the weight of furniture
from trafc can damage the cables.
Flexible cables should neither be in contact with, or close to, hot surfaces nor extend into the immediate
vicinity of such, as they are not suitable for this purpose.
On account of their characteristics, this also applies in particular for PVC-sheathed and/or jacketed cables.
The suitability of exible cables for outdoor applications, either for short periods or continuous operation,
is dened in the tables of the HD 516 and in DIN VDE Part 300.
Flexible PVC-sheathed cables are not suitable for permanent use in outdoor applications.
The types of structures for PVC-sheathed cables for short-term use in outdoor applications should not
however be operated in conditions others than these, e.g. at temperatures lower than the specied
temperature.

X 94
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Safety Requirements in the Use of Cables and


Insulated Wires
Cables without a jacket may neither be used as a substitute for a jacketed cable nor as an extension cable.
These shall principally not be used for connecting Class 2 equipment unless the cable in the constructional
standard has been dened as a cable for extra light duty and the equipment standard explicitly permits this
cable type.
The corresponding VDE and HD regulations shall be observed for the cables used in deep mining operations, in quarrying as well as for moveable equipment, such as in cranes with spring-loaded reeling devices
for example.

Voltage
The rated voltage for a cable is the reference voltage for which the cable is designed and which serves to
dene the electrical testing requirements.
The rated voltage is expressed as the ratio of two values, U0 /U, whereby U0 is the effective value (r.m.s.)
of the voltage between any insulated conductor and the earth (metal covering of the cable or
surrounding medium)
U is the effective value (r.m.s.) between any two phase conductors of a multicore cable or of a system of
single core cables. In an alternating current system, the rated voltage of a cable shall be at least equal to the
nominal voltage to the value U0 and U. In direct current system, the rated voltage of the system shall not be
higher than 1,5 times that of the nominal voltage of the cable.
Note: The operating voltage of a system may permanently exceed the rated voltage for the cable by 10 %.

Current carrying capacity


The nominal cross-section of each conductor should be selected such that the current carrying capacity is
not less than the maximum continuous current that ows through the conductor under normal conditions
of operation. The limiting temperature with respect to the current carrying capacity should not be
exceeded for the cable insulation and sheath concerned.
Included in the dened conditions is also the method of installation for the cable used. The regulations for
the permissible current rating shall be observed here for the current.
Correction factors may also be included in the values given for the load rating to allow for other conditions,
such as for example:
1. cable grouping
2. type of overcurrent protection
3. ambient temperature
4. reeled / drummed cables
5. thermal insulation
6. frequency of the current (if other than 50 Hz)
7. effects of harmonic waves
Serious damage can be caused if cables are operated for longer periods of time above those limits given in
the tables and can lead to early failure or considerable deterioration in the cable characteristics.

Thermal inuences
Cables should be selected, located and installed so that the intended heat dissipation is not inhibited and
they do not present a re hazard to adjacent materials.
The limiting temperatures for the individual cables are given separately in our catalogue. Under no circumstances may these values be exceeded by an interaction of internal joulean heat (to the material of the
cable, connections and terminals) by the ambient conditions.

X
X 95
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Safety Requirements in the Use of Cables and


Insulated Wires
Mechanical stress
Allowance shall be made for all possible mechanical stress that can arise during a normal installation
process for laying cable in order to assess the risk of mechanical damage to cables.

Tension
The following values for tension should not be exceeded for each conductor in use. This applies up to a
maximum value of 1000 N for the tensile stress of all conductors unless HELUKABEL has approved limits
deviating from this value.
50 N/mm2 by permanent operation for xed installation.
15 N/mm2 for exible cables under static tension for xed installation that are used in current circuits.
It is recommended for those cases where the above values are exceeded, that a separate strain-relieving
element or similar protection should be used. The connection of such a strain-relieving element to the
cable shall be made such that the cable is not damaged.
If exible cables are subjected to dynamic tensile stress (including those due to the mass inertia, e.g.
for reeling drums), the permissible tension or the fatigue life should be agreed between the user and
HELUKABEL.
Notes for cables which are installed vertically, without any intermediate support, can be found in DIN VDE
0298 part 300 and HD 516 S2, item 5.4.1, and Table 6.

Bending stress
The internal bending radius of a cable should be chosen such that the cable is not damaged by this.
The internal bending radii are given in Table 6 of HD 516 S2 and DIN VDE 0298 part 300.
The choice of bending radii smaller than specied shall be concurred with HELUKABEL.
Attention shall be given when stripping the insulation that the conductor is not damaged by this as the
bending characteristics will otherwise seriously deteriorate.
The bending radii given apply for ambient temperatures of (20 10)C. The recommendations from
HELUKABEL shall be enquired for ambient temperatures other than those given.
For exible cables and cords, particularly at terminations and at the point of entry of moveable appliances,
it may be necessary to use a device which ensures that the cable is not bent to an internal bending radius
less than that specied in Table 6 of HD 516 S2 and DIN VDE 0298 part 300.
Bending too close to any internal and/or external anchorage shall be avoided.
Kink-protection sleeves or other devices shall not impede the movement of the cores within the cable.

Compression
Cables shall not be compressed to an extent that this will damage the cable.

Torsional stress
In general, exible cables are not designed for torsional stress. In those cases where such torsional stress
cannot be avoided, then the design of the cable and the installation arrangements should be agreed
between user and HELUKABEL.

X 96
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Safety Requirements in the Use of Cables and


Insulated Wires
Compatibility
The following points shall be considered in the selection and installation of cables:
The avoidance of interference mechanical and electrical inuences between adjacent circuits.
Dissipation of heat from cables, or the chemical/physical inuences from the materials used for the cables
on bordering materials, such as for example, constructional and decorative materials, insulation tubes,
supports, etc.
Mutual interference by adjacent materials and the materials used for the cables. This applies for instance,
for an absorption of plasticiser from PVC-sheathed cables by certain materials that are used for thermal
insulation purposes, for strapping materials or for the equipment.

Dynamic stress
The possibility should be taken into consideration of damage to cables and fastenings for these, by the
dynamic forces that can be caused by any current including short-circuit currents.

Storage/Handling/Transportation
Cables that are not intended for outdoor applications should be stored in dry indoor environments.
A number of constructional types of exible cables are particularly susceptible to moisture, such as
screened cables for example.
The ends of the cables should be sealed for the application and the expected duration of outdoor storage
in order to prevent the penetration of moisture. The temperatures given in the tables in HD 516 S2 for
storage shall be taken into account.
If the temperature of the cable falls below recommended values, then all types of mechanical stresses, in
particular vibrations, shock, impact, bending and torsional twist shall be avoided.

X
X 97
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Glossary of Terms: Cables and Wires


Standard Wire Gauge (SWG), New British Standard
(NBS), English Legal Standard, and Imperial Wire Guide.

A
Acceptance angle - The half-angle of the cone
within which incident light is totally internally
reected by the ber core. It is equal to arcsin (NA).
 = arc sin

n n
2
1

2
2

Aerial cable - A cable suspended in the air on poles


or other overhead structure.
Appliance Wire and Cable - A classication
covering insulated wire and cable for internal wiring
of appliances and equipment.
Armoured Cable - A cable provided with a
wrapping of metal for mechanical protection.

Building Wire - Insulated wires used in building for


light and power, 600 volts or less, usually not
exposed to outdoor environment.
Buffer - A protective coating over an optical bre. A
soft material extruded tightly over the bre coating,
mechanically isolates individual bres.
BUS - A network which functions like a signal line
and is shared by a number of nodes.

ASA - Abbreviation for American Standards


Association. Former name of ANSI.

Cable - Multicore stranded insulated wires under


protective sheath to conduct electrical energy e.g.
power cable, telecommunication cable, installation
cable, data cable etc.

ASME - Abbreviation for American Society of


Mechanical Engineers.

Cable Core - The portion of an insulated cable lying


under the protective covering.

ASTM - Abbreviation for the American Society for


Testing and Materials.

Cable Sheath - A protecting covering over the


cable core to prevent outer damages.

ATM (Asynchronous Transfer Mode) - A new


emerging data standard that uses many of the same
data rates as Fiber Channel and SONET.

Capacitance (Capacity) - That property of a


system of conductors and a dielectric which permits
the storage of electricity when potential difference
exists between the conductors. A capacitance value
is always positive.

Attenuation - The power drop or signal loss


in a circuit, expressed in decibels (db). Generally
attenuation increases (signal level decreases) with
both frequency and cable length.

Capacitive Coupling - Electrical interaction


between two conductors caused by the capacitance
between them.

AWG - Abbreviation for American Wire Gauge. A


standard measurement of the size of a conductor.

CATV - Acronym for Community Antenna Television.

AWM - Designation for Appliance Wiring Material.

CEBEC - Belgium approval agency; Comite


Electrotechnique Belge Service de la Marque.

CEE - European standards agency; International


Commission on Rules for the Approval of Electrical
Equipment.

Bit - A binary digit, smallest element of information


in binary system.
Bit (Binary Digit) - A basic unit for the datas of a
digital transmitting system. A group of 8 Bit is usually
expressed as one Byte.
Bit rate - The number of bits of data transmitted
over a phone line per second.
B & S Gauge - Standard for Brown & Sharpe Gauge.
The wire diameter standard is same as AWG.
Breakdown Voltage - The voltage at which the
insulation between two conductors will break down.
Performed as a type test in the laboratory.
British Standard Wire Gauge - A modication of
the Birmingham Wire Gauge and the legal standard
of Great Britain for all wires. It is variously known as

Cellular insulation - Insulating material in


foamed or sponge form with the cells closed or
interconnected.
CENELEC - European standards agency; European
Committee for Electrotechnical Norms.
Chromatic dispersion - The speed of an optical
pulse travelling in a ber changes if its wavelength
changes. Chromatic dispersion can be measured
by the measurement of travel time at different
wavelength.
Circuit - The entire route of an electrical current. A
complete path over which electrons can ow from
the negative terminals of a voltage source through
parts and wires to the positive terminals of the same
voltage source.

X 98
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Glossary of Terms: Cables and Wires


C
Circuit Sizes - A popular term for building wire
sizes 14 through 10 AWG.
Circular Mil (CM) - Used to dene cross-sectional
areas of conductors. Area of a circle 1/1000 inches in
a diameter. 1 mil (0,001 inch) is equal to square
mil x 0,78540.
Cladding - A low-refractive index, glass or
plastic that surrounds the core of a ber. Optical
cladding promotes total internal reection for the
propagation of light in a ber.
Coaxial Cable - A cable consisting of two cylindrical
conductors with a common axis, separated by
a dielectric. The outer conductor or shield is
commonly used to prevent external radiation from
affecting the current owing in the inner conductor.
Coherent waves - The phenomenon related to
the existence of a correlation between the phases
of the corresponding components of two waves
or between the values of the phase of a given
component of one wave at two instants in time or
two points in space.

Corona - A discharge due to ionization of air


around a conductor with a potential gradient
exceeding a certain critical value. A high voltage
electrical discharge that attacks insulation.
Crimp - Act of compressing a connector barrel
around a cable in order to make an electrical
connection.
Cross-linked - Setting up the chemical links
between the molecular chains. A form of
polyethylen material whose moleculars are
more closely linked to produce a greater
balance of physical and electrical properties.
(XLPE - compound)
Crosstalk - Interference caused by audio
frequencies. Undesired electrical currents in
conductors caused by electromagnetic or
electrostatic coupling from other conductors or
from external sources. Also, leakage of optical power
from one optical conductor to another.
CSA - Abbreviation for Canadian Standards
Association, a non-prot independent organization
which operates a listing service for electrical and
electronic materials and equipment. The Canadian
counterpart of the Underwriters Laboratories.

Colour Code - A system of identifying different


insulated cores by means of colours, numbers,
printing etc.

Current - Flow of electricity measured in amperes.


Practical unit is the ampere which represents the
transfer of one coulomb per second.

Concentric lay - Cable core composed of a central


core surrounded by one or more layers of helically
laid insulated wires or cores.

Current rating - The maximum continuous


electrical ow of current recommended by a given
wire in a given situation, expressed in amperes.

Conductor - A material capable of easily carrying


an electrical conductivity. A wire or combination of
wires not insulated from one another, suitable for
carrying electric current.

Cut off wavelength - For a singlemode ber,


the wavelength above which the ber exhibits
singlemode operation.

Control Cable - A multi-conductor cable made for


operation in control of signal circuits.
Copolymer - A compound resulting from the
polymerization of two different monomers.
Copperweld - Copper covered steel wire. Copper
and steel welded together. The trade name of Flexo
Wire Division (Copperweld Steel Corp.) for their
copper-clad steel conductors.
Cord - A small, exible insulated cable.
Cord Set - Portable cords tted with a wiring device
at one or both ends. Cord is a small exible insulated
conductor or group of conductors, normally not
larger than AWG 10 - up to 4 cores.
Core - In cables, a component or assembly of
components over which other materials are applied,
such as additional components, shield, sheath, or
armour.

D
dB - see decibel
D. C. - Abbreviation for direct current (D C),
Electricity that ows in one direction only.
Decibel (dB) - One-tenth of a bel. Unit to express
differences of power level. Example: The decibel is
10 times the common logarithm of the power ratio.
It is used to express power gain in ampliers or
power loss in passive circuits or cables.
DEMKO - Approval agency of Denmark. Denmarks
Elektriske Material Kontrol.
Dielectric Breakdown - The voltage required to
cause an electrical failure or breakthrough of the
insulation.
X 99

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Glossary of Terms: Cables and Wires


Dielectric Strength - The maximum voltage
insulation can withstand without rapture. Usually
expressed as a voltage gradient, e. g. volts per mil.

Ferrule - A component of a connector that holds


ber in place and aids in its alignment, usually
cylindrical in shape with a hole through the center.

Dispersion - A general term for those phenomena


that cause a broadening or spreading of light as it
propagates through an optical ber. The three types
are modal, material, and waveguide

Filled Cable - A telephone cable construction in


which the cable core is lled with a material that will
prevent moisture from entering or passing through
the cable.

Drain Wire - An uninsulated wire used as an


earth connection. This is generally laid over the
component or under the screening, braiding etc.

Fine Stranded Wire - Stranded wire with


component strands of 36 AWG or smaller.

Duct - An underground or overhead tube or conduit


for carrying electrical cables.

E
EIA - Abbreviation for Electronic Industries
Association.
Elastomer - Any material that will return to its
original size after stretching. Elastomer is a rubber or
rubber-like material which will stretch repeatedly to
200 percent or more and return rapidly with force to
its approximate original shape.
Electromagnetic Coupling - Energy transfer by
means of a varying magnetic eld.
Electromagnetic Induction - The production of
a voltage in a coil due to a change in the number
of magnetic lines of force (ux linkages) passing
through the coil.

Flame Resistance - The ability of a material not to


propagate ame once the heat source is removed.
Flammability - The measure of the materials
ability to support combustion.
Flat Cable - A cable in at form, where the cores
lying parallel longitudinally but essentially with at
surfaces.
Foamed Plastics - Insulations having a cellular
structure.
Foils - A thin supporting lm of continuous sheet
such as plastic foil, metal foil, laminated foil etc.
for static shielding, contacts and other electrical
applications.
FR-1 - A ammability rating established by
Underwriters Laboratories for wires and cables that
pass a specially designed vertical ame test. This
designation has been replaced by VW-1.
FRNC - Flame Retardant Non Corrosive

Elongation - The fractional increase in the length of


a material stressed in tension.

EMC - Electromagnetic Compatibility (EMV).

Gauge - A term used to denote the physical size of


a wire.

EMF - Abbreviation for Electro Motive Force force


determinating ow of electricity (voltage).
EMI - Any electrical or electromagnetic interference
that causes undesirable response, degradation, or
failure in electronic equipment. Optical bers neither
emit or receive EMI.

Graded-index ber - An optical ber whose core


has a nonuniform index of refraction. The core
is composed of concentric rings of glass whose
refractive indices decrease from the center axis. The
purpose is to reduce modal dispersion and thereby
increase ber bandwidth.

EMV - Designation for electromagnetic compatibility


(EMC).

Ground Conductor - An electrical conductor for


the connection to the earth, making a complete
electrical circuit.

EPR - Ethylene-propylene copolymer rubber. The


copolymer is chemically cross-linked.

ETFE - Ethylene tetrauoroethylene

Helix - A continuous spiral winding.


Henry - The unit of inductance (H).

F
FDDI - Fiber Distributed Data Interface. Very high
speed Computer Network working with ber optics.
FEP - Fluorinated ethylene propylene

Hertz (Hz) - A unit of measurements of the


frequency equal to one cycle per second.
High Temperature Wire and Cable - Electrical
wire and cables having thermal operating
characteristics of 150C and higher.

X 100
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Glossary of Terms: Cables and Wires


Hi-Pot - A test designed to determine the highest
voltage that can be applied to a conductor without
electrically breaking down the insulation.
High Voltage - Generally, a wire or cable with an
operating voltage of 600 volts and above.
Hook-up Wire - Single conductor used to hook-up
electrical parts of instruments for low current and
voltage (under 1000 volts).
Hybrid Cable - Multi-conductor cable containing
two or more types of components.
Hypalon - Du Ponts trade name for their
chlorosulfonated polyethylene, an ozone resistant
synthetic rubber (90C).
Hz - Abbreviation for Hertz.

Jumper - A short length of conductor used to make


a temporary connection between terminals, around
a break in a circuit, or around an instrument.

K
KEMA KEUR - Approval agency of Netherlands.
Keuring van Elektrotechnische Materialien.
KV - Abbreviation for kilovolt = 1000 volts.
KVA - Abbreviation for kilovolt
ampere = 1000 volts x amperes.
KW - Abbreviation for kilowatt = 1000 watt.
Kynar - Fluorocarbon insulation rated -65C
to +135C, typically used as insulation for wire
wrapwire. A Pennwalt trade name for polyvinylidene
oride.

ICEA - Abbreviation for Insulated Cable Engineers


Association.
IEC - European Standardization agency; International
Electrotechnical Commission.
IEEE - Abbreviation for Institute of Electrical and
Electronics Engineers.
Impedance - Resistance to ow of an alternating
current at a particular frequency, expressed in ohms.
It is a combination of resistance R and reactance X,
measured in ohms.
Index prole - A graded-index optical ber, the
refractive index as a function of radius.
Induction - An inuence exerted by a charged body
or by a magnetic eld on adjacent bodies without
apparent communication.
Inductive Coupling - Crosstalk resulting from the
action of the electromagnetic eld of one conductor
on the other.
Insulation - A non-conducting substance, named
as dielectric, surrounding the conductor.
Interface - The two surfaces on the contact side of
both halves of a multiple-contact connector which
face each other when the connector is assembled.
Common interconnection point for devices, e.g.
RS232 Interface: Mouse-Personalcomputer.
ISDN - Integrated Services Digital Network. A
standard protocol for digital telecommunications
transmissions.

J
Jacket - An overall covering of a cable, called also
sheath which protects against the environment
and stress.

L
Laser - Light Amplication by Stimulated Emission
of Radiation. An electro-optic device that produces
coherent light with a narrow range of wavelengths,
typically centered around 780 nm, 1310 nm,
or 1550 nm.
Laminated Tape - A tape consisting of two or more
layers of different materials bonded together.
LAN = Local Area Network - A network located in
a localised area e.g. in an ofce, building, complex
buildings whose communication technology
provides a high-bandwidth, low-cost medium to
which many nodes can be connected.
LED - Light Emitting Diode.
LOCA - Abbreviation for Loss of Coolant Accident,
a system malfunction associated with nuclear
generating stations.
Loop Resistance - The total resistance of two
conductors in a closed circuit, measured round trip
from one end.
Loss Factor - The loss factor of an insulating
material is equal to the product of its dissipation and
dielectric constant.

M
MCM - Cross-section of greater AWG-sizes. 1 MCM=
1000 circular mils = 0,5067 mm2.
Meg or Mega Prex meaning 1 million = 1.000000 = 106.

X
X 101

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Glossary of Terms: Cables and Wires


M
Megarad - A unit for measuring radiation dosage.
1 megarad = one million rads = 106 rad or 106 cJ/kg.
Mho - The unit of conductivity. The reciprocal of an
ohm.
MHz - One million cycles per second =
megahertz = 106 Hz.
Modem - Abbreviation for Modulator/Demodulator.
Device which allows to transmit electrical data
via analogues transmission paths with limited
bandwidth, e. g. Computer data via telephone lines.
MTW - An acronym for thermoplastic insulated
Machine Tool Wire.
Multi-conductor - A combination of two or more
conductors in a cable under jacket.
Multimode-Fiber - A type of optical ber that
supports more than one propagation mode.
Mutal Capacitance - Capacitance between
two conductors when all other conductors are
connected together to shield and ground.
Mylar - Du Pont trademark for polyester material.

NFPA - Abbreviation for National Fire Protection


Association. Administrative Sponsor of the National
Electric Code (ANSI Standards Committee CI).
Numerical Aperture NA - The light-gathering
ability of a ber, dening the maximum angle to
the ber axis at which light will be accepted and
propagated through the ber. NA = sin , where is
the acceptance angle.
NA = sin -max =

n n
2
1

2
2

Nylon - A group of polyamide polymers, used for


wire and cable jacketings with good chemical and
abrasion resistance.

O
Ohm - The electrical unit of resistance. The value of
resistance through which a potential difference of
one volt will maintain a current of one ampere.
Optical Fiber - Any lament or ber, made of
dielectric materials, that guides light, whether or
not it is used to transmit signals. Synonym: optical
waveguide.
OSHA - Abbreviation for Occupational Safety and
Health Act. Specically the Williams-Steiger law
passed in 1970 covering all factors relating to safety
in places of employment.

N
National Electric Code Article 725 - The NEC
Article which covers remote control, signal and
communication power limited circuits that are not
an integral part of the device or appliance.
National Electric Code Article 760 - The NEC
Article which covers the re and burglar alarms
installation of wire and equipment operating at
600 Volts or less.
National Electric Code (NEC) - A set of
regulations governing construction and installation
of electrical wiring and apparatus in the United
States, established by the American National Board
of Fire Underwriters.
NEMA - National Electrical Manufacturers
Association.
NEMKO - Approval agency of Norway. Norges
Elektriske Materiellkontroll.
Neoprene - A synthetic rubber of thermosetting
material with good resistance to oil, chemical, and
ame, known as polychloroprene - mostly used as
jacketing.
Neper - An electrical unit similar to decibel, used to
express the ratio between two amount of power
existing at two distinct points. 1 Neper = 8,686
decibels.

OVE - Approval agency of Austria.


Overlap - A certain portion of a foil or band
which laps over the leading edge of a helical or
longitudinally wrapping tape.
Ozone - A faintly blue gasious, reactive form
of oxygen, obtained by the silent discharge of
electricity in ordinary oxygen or in air.
Ozone Index - Percentage of oxygen necessary to
support combustion in gas mixture.

P
Pair - 2 insulated wires twisted together in a certain
lay-length to built a single circuit of transmission
line.
Patch Cable - A cable with plugs or terminals
on each end of the conductors to temporarily
connect circuits of equipment together. In the IBM
Cabling System, a length of Type 6 cable with data
connectors on both ends.
Patch Cord - A exible piece of electrical cord
terminated at both ends with plugs, used for
interconnecting circuits on a pasteboard.
Patch Panel - Distribution area to rearrange ber
connections and circuits.

X 102
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Glossary of Terms: Cables and Wires


pH - The measure of acidity or alkalinity of a
substance. PH values are described from 0 to 14.
Value 7 indicate the neutrality. Numbers below 7
result increasing acidity and number greater than 7
increasing alkalinity.
Pick - Distance between two adjacent crossover
points of braiding wires or laments, measured in
picks per inch.
Pigtail - A short length of optical ber, permanently
xed to a component, used to couple power
between the component and a transmission ber.
Plenum - The air return way of a central air handling
system, either ductwork or open space over a
dropped ceiling.
Plenum Cable - Cable approved by Underwriters
Laboratories for installation in plenums without the
need for conduit.
Plug - The part of the two mating halves of a
connector which is movable when not fastened to
the other mating half.

Polyvinyl Chloride (PVC) - This is a group of


thermoplastic compounds composed of polymers
of polyvinyl chloride or its polymer, vinylacetate,
in combination with certain stabilizers, llers,
plasticizers, pigments etc., widely used for wire and
cable insulations and several jackets.
Power Cables - Cables of several sizes,
construction, and insulation, single or multiconductor, designed to distribute primary power
to various types of equipment, such as cables
 0,6/1 kV.
Power Factor - The ratio between the true power
in watts and the apparent power in volts amperes.
Primary Coating - The plastic coating applied
directly to the cladding surface of the ber during
manufacture to preserve the integrity of the
surface.
Printed Wiring - A printed circuit intended to
provide point-to-point electrical connections.
Propagation - Delay time required for an electrical
wave to travel between two points on a transmission
line.

Polychloroprene - Chemical name of neoprene.


A rubber-like compound for jacketing and also for
insulating where cables are subject to rough usage,
oils, moisture, solvents, greases and chemicals.
Polyester (PETP) - A resin formed by the reaction
between a dibasic acid and a dithydroxy alcohol.
Polyethylene terephthalate, used extensively as a
moisture resistant cable core wrap.
Polyethylene (PE) - This material is basically
pure hydrocarbon resins with excellent dielectric
properties, i. e. low dielectric constant, low dielectric
loss across the frequency spectrum, mechanically
rugged and resists abrasion and cold ow. The
insulating materials derived from polymerization of
ethylene gas.
Polyerm - A material of high molecular weight
formed by polymerization of lower molecular weight
molecules.
Polyolen - A group of thermoplastics based upon
the unsaturated hydrocarbons, known as olens.
When combined with butylene or styrene polymers,
the form compounds such as polyethylene and
polypropylene.
Polypropylene (PP) - A thermoplastic similar to
polyethylene but stiffer and having higher softening
point (temperature); excellent electrical properties.
Polyurethane (PUR) - Class of polymers known for
good abrasion and solvent resistance. A copolymer
of urethane is similar in properties to neoprene,
usually used as a coldcuring moulding compound.

R
Rayleigh Scattering - The scattering of light that
results of from small inhomogeneities in material
density or composition.
Reel - A revolvable anged device made of wood or
metal, used for winding of wires or cables.
Refractive index - The ratio of the velocity of light
in a vacuum to its velocity in the medium. Synonym:
Index of Refraction.
Resistance - Property of an electric circuit which
determines for a given current the rate at which
electric energy is converted into a heat and has a
value, is measured in ohms.
RG/U - Abbreviation for Radio Government,
Universal. RG is the military designation for coaxial
cable in Mil-C-17. R = Radio, G = Guide, U = Utility.
Ribbon Cable - A at cable consisting of two or
more insulated conductors laid parallel in one plane
and held together by means of adhesive or woven
textile yarns.
RMS (Root Mean Square) - The effektive value of
an alternating current or voltage.
Rubber (Wire Insulation) - Term used to describe
wire insulations made of thermosetting elastomers,
occur naturally or may be made synthetically.
X 103

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Glossary of Terms: Cables and Wires


S
S - Rubber insulated heavy duty exible cable,
stranded copper wires with separator. Two or more
colour coded, stranding with ller, wrapped with
separator, rubber jacket. 600 V.
Semi-Rigid - A cable containing a exible inner core
and a relatively inexible sheathing.
Semi-Rigid PVC - A hard semi-exible
polyvinylchloride compound with low plasticizer
content, (shore A 97), for Termi-Point connecting
technique.
Semi-Solid - An insulation cross-section having a
partially open space between the conductor and the
insulation perimeter.
SEMKO - Approval agency of Sweden.
Separator - A layer of insulating material which
is placed between a conductor and its dielectric,
between a cable jacket and the component it covers,
or between various components of a multipleconductor cable.
Silicone - A thermosetting elastomer with excellent
heat-resistant. Polymeric materials in which the
recuring chemical groups contain silicon and oxygen
atoms at links in the main chain.
Simplex - Transmission only in one direction.
Singlemode-Fiber - A small-core optical ber that
supports only one mode of light propagation above
the cutoff wavelength. Typical diameter is 9 10 mm,
the dispersion very low. Singlemode bers are
proper for long distance transmissions.
SJ - Junior hard service, rubber-insulated pendant
or portable cord. Same construction as type S, but
300 V. Jacket thickness different.
SJO - Same as SJ, but neoprene, oil resistant
compound outer jacket. Can also be made
waterresistant 300 V, 60C.
SJT - Junior hard service thermoplastic or
rubberinsulated conductors with overall
thermoplastic jacket. 300 V, 60C to 105C.
SJTO - Same as SJT but oil resistant thermoplastic
outer jacket. 60C.
SO - Hard service cord, same construction as type S
except oil resistant neoprene jacket. 600 V, 60C to
90C.
SOOW like SO, but oil and water-resistant.
Solid Conductor - A conductor consisting of a
single wire.

SONET - Synchronous Optical Network.


SP-1 - All rubber, parallel-jacketed, two-conductor
light duty cord for pendant or portable use in damp
locations. 300 V.
SP-2 - Same as SP-1, but heavier construction,
with or without third conductor for grounding
purposes. 300 V.
SP-3 - Same as SP-2, but heavier construction for
refrigerators or room air conditioners. 300 V.
SPT-1 - Same as SP-1, except all-thermoplastic. 300
V. With or without third conductor for grounding.
SPT-2 - Same as SP-2, except all-thermoplastic. 300
V. With or without third conductor for grounding.
SPT-3 - Same as SP-3, except all-thermoplastic. 300
V. With or without third conductor for grounding.
Spark Test - A test designed to locate pinholes in an
insulated wire by application of an electrical potential
across the material for a very short period of time
while the wire is drawn through an electrode eld.
Splice - An interconnection method for joining
the ends of two optical bers in a permanent or
semipermanent fashion. Maybe thermally fused or
mechanically applied.
ST - Hard service cord, jacketed, same as type S,
except all-plastic design. 600 V, 60C to 105C.
Step index Fiber - An optical ber, either multimode or singlemode, in which the core refractive
index is uniform throughout so that a sharp step
in refractive index occurs at the core-to-cladding
interface.
STO - Same as ST but with oil resistant thermoplastic
outer jacket. 600 V, 60C.
SV - Vacuum cleaner cord, two or three-conductor,
rubber-insulated. Overall rubber jacket. For light
duty in damp locations. 300 V, 60C.
SVO - Same as SV except neoprene jacket. 300 V, 60C.
SVT - Same as SV except all-plastic, construction.
With or without third conductor for grounding
purposes only. 300 V, 60C to 90C.

T
Tape Wrap - A spirally applied tape over an insulated
or uninsulated wire.
Tear Strength - The force required to initiate
or continue a tear in a material under specied
conditions.
Temperature Rating - The maximum temperature
at which an insulating material may be used in continuous operation without loss of its basic properties.

X 104
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Glossary of Terms: Cables and Wires


TEW - Canadian Standard Association type appliance
wires. Solid or stranded single conductor, plasticinsulated. 600 V, 105C.

Velocity of light - The velocity of light is 300.000


km/s in vacuum. In a medium it depends on the
refractive index and the wavelength.

TF - Fixture wire, thermoplastic-covered solid or 7


strands. 60C.
TFE - Tetrauoroethylene.

Velocity of Propagation - Ratio of speed of ow


of electric current in an insulated cable to the speed
of light. Usually expressed in percentage.

TFF - Same as TF but exible stranding. 60C.

Volt - A unit of electromotive force.

THHN - 90C, 600 V nylon jacketed building wire.

Voltage - The term most often used in place of


electromotive force, potential difference, or voltage
drop to designate the electric pressure that exists
between two points and is capable of producing a
current when a closed circuit is connected between
two points.

Thermocouple Lead Wire - An insulated pair of


wires used from the couple to a junction box.
Thermoplastic - A material which softens when
heated and becomes rm on cooling.
THW - Thermoplastic vinyl insulated building wire.
Flame-retardant, moisture and heat-resistant 75C.
Dry and wet locations.

Voltage Drop - The amount of voltage loss from


original input to point of electrical device.

THWN - Same as THW but with nylon jacket overall.


75C.

Voltage Rating - The highest voltage that may be


continuously applied to a wire in comformance with
standards.

Transmission - Transfer of electric energy from one


location to another through conductors or by
radiation or induction elds.
Tray Cable - A factory-assembled multi-conductor
or multipair control cable approved under the
National Electrical Code for installation in cable trays.
Triaxial Cable - A three-conductor cable
constructed in three coincident axes, of which one
conductor in the centre, second circular conductor
concentric with the rst and the third circular
conductor insulated from the concentric with the
rst and second, usually with insulation, a braiding
and a outer jacket.

VW-1 - A ammability rating established by


Underwriters Laboratories for wires and cables
that pass a specially designed vertical ame test,
(formerly designated FR-1).

W
Wall Thickness - The thickness of the applied
insulation or jacket.
WAN - Wide Area Network. A network of connected
computers that covers a great geographical area.

TW - Thermoplastic vinyl-jacketed building wire,


moisture resistant 60C.

Water Absorption - A test to determine the water


absorbed by a material after a given immersion
period.

Twisted Pairs - A cable composed of two small


insulated conductors twisted together without a
common covering.

Wire - A conductor, either bare or insulated. A


slender rod of metal usually referring to a single
conductor, such as size 9 AWG and smaller.

Wire Gauge - A system of numerical designation of


wire sizes.

UL - Abbreviation for Underwriters Laboratories, Inc.


Ultraviolet - Optical radiation for which the
wavelengths are shorter than those for visible
radiation, that is approximately between 1 nm and
400 nm.

Unilay Stranding - A conductor constructed


in bunch form having more than one layer in a
concentric stranding with a common length and
direction of lay and contains 19, 27, 37 and any
number of strands.

VDE - West Germany approval agency.

Zytel - Du Ponts trade name for nylon resins.

XLPE - Cross-linked polyethylene.

Yield Strength - The minimum stress at which


a material will start to physically deform without
further increase in load.

X
X 105

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

International Certication Marks and


Testing Institute
Country

Certication marks

Testing Institutes/
Registration Agency

Belgien

Comit Electrotechnique Belge


Belgisch Elektrotechnisch Comit
(CEBEC)

China

Chinesische Zwangsluge Zertikation


(China Compulsory Certication)

Denmark

Danmarks Elektriske Materielkontrol


(DEMKO)

Germany

VDE-Prfstelle
(Verband Deutscher Elektrotechniker e. V.

Germany

VDE-Prfstelle
(Verband Deutscher Elektrotechniker e. V.

Germany

Fraunhofer Institut
Produktionstechnik und Automatisierung

Europe

Communaut Europenne

Finland

FIMKO LTD

France

Union Technique de lElectricit (UTE)

Great Britain

BSI
British Standards Institution
(Zeichenvergabestelle)

Italy

IMQ
Instituto Italiano de Marchio Qualit

Canada

Canadian Standards
Association (CSA)

Netherlands

Naamloze Vennootschap tot Keuring


van Electrotechnische Materialen
(KEMA)

Norway

Norges Elektriske Materiellkontroll


(NEMKO)

Austria

sterreichischer Verband fr
Elektrotechnik (Registration Agency)

Russia

GOST-R Certication
(SGS)

Sweden

Svenska
Elektriska Materielkontrollanstalten
(SEMKO)

Switzerland

Schweizerischer
Elektrotechnischer Verein
(SEV)

USA

Underwriters
Laboratories (UL)

X 106
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Formulas of electrotechnic and electronic


Cross-section for single wire round
2
D2 0,7854
q = D or
4
Cross-section for bunched wire
2
q = d n or d2 0,7854 n
4
Diameter for
single wires cross-section
D =

q 4

or

q 1,2732

Diameter for bunched wires


D =

 1,34 n d

q = cross-section (mm2)
D = conductor diameter (mm)
d = single wire diameter (mm)
n = number of wires

Ohms Law
The current intensity (I) is proportional to voltage (U) and inversely
proportional to resistance (R)
I = U R = U
U = I R
R
l
I = current intensity (Amps - A)
R = electrical resistance (1)
U = electrical voltage (V)
Conductance
1
1
G = 1
1S =
or 1 S =
1M1
R
1 1
S (Siemens) = reziprocal value of a resistance
is used as conductance
1 Siemens = 1/Ohm
G = electrical conductance
Capacitance
Single core against earth
r 103
CB =
(nF/km or pF/m)
18 ln Did

Conductor Resistance
O

O
R
=
oder
q
q
2

O
2
O p
=
oder
R Schleife
q
q
R
= Electrical direct-current resistant (Ohm)
R Schleife
= Resistance of a complete circuit
q
= cross-section (mm2 or q mm)
(Kappa)
= Conductivity
1 )

(Rho)
= Specic resistance (
=
I
= Conductor length (m)

Unshielded symmetrical twisted pair


r 103
CB =
2a (nF/km or pF/m)
36 ln d
Coaxial pair
r 103
CB =
Di (nF/km or pF/m)
18 ln d
Shielded symmetrical twistet pair
r 103
CB =
(nF/km or pF/m)
2a (Da2 a2)
36 ln d (Da2 a2)

Materials

Di = outer diameter over single core (mm)


Da = outer diameter of multicores (mm)
d = conductor diamete (mm)
a = distance between two conductors mid to mid of both conductors
Inductance of parallel cores
at low frequencies
L = 0,4 (In Da
r + 0,25) mH/km

Copper

Conductivity

Spec. resistance

m
1 mm2

1 mm2
m

58,00

0,01724

Aluminium

33,00

0,0303

Silver

62,00

0,0161

Iron

7,70

0,1299

Constantan

2,00

0,50

Serial connection
Resistance:
R = R1 + R2 + R3 + ... + Rn
1
Capacitance:
+ 1 + 1 + 1 + ... + 1
Cn
C
C 1 C2 C3
Inductance:
L = L1 + L2 + L3 + ... + Ln
Parallel connection
Resistance:
R = 1 + 1 + 1 + ... 1
Rn
R1 R2 R3
Capacitance:
C = C1 + C2 + C3 + ... Cn
L = 1 + 1 + 1 + ... 1
L 1 L2 L3
Ln
Equivalent resistance of 2 parallel connected resistance
R = R1 R2
R1 + R2
Mutual capacity (C)
r 103
C=
coaxial cable
18 ln Da (nF/km)
Inductance:

C=

parallel core

r 103
36 ln Da (nF/km)
d

shielded twisted pair


r 103
CB =
(Da2 a2)
2a
36 ln d 2 2

(nF/km)

(Da a )

Da =
Ds =
d =
a =
=

Outer diameter over insulation


diameter over shield
diameter of conductor
distance - mid to mid of both
conductors
dielectric constant

at high frequencies
L = 0,4 (In Da
r + 0) mH/km
Inductance of coaxial cable
at high frequencies
L = 0,2 (In Da
r + 0) mH/km
Da = distance between two conductors mid to mid of both conductors
r = radius of a conductor
r = dielectric constant
Impedance (Z)
for coaxial cable
Z = 60 In D (1)
d
 r
D = diameter over insulation
d = conductor diameter
for communication cable
at low frequencies
Z=




R (1) tan = 1, = 45
C

L (1)
at high frequencies
Z=
C
R = Resistance (1/km)
L = Inductance (mH/km)
C = Capacitance (nF/km)
 = 2f
Wave length  = v
f
 = wave length
V = propagation velocity
(velocity of light: 300 000 km/s)
f = frequency
units of attenuation - Neper (N), decibel (dB) and Bel (B)
1 Np = 8,686 dB
1
1 dB = 0,1151 Np = 10 Bel
1 Bel = 10 dB = 1,1513 Np

X
X 107

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Formulas of power engineering


Cross section
for direct current and single
2 ,O(mm2
phase alternative current
q=
)
u
one-phase current

of known current
q = 1,732 ,cos O(mm2)
for three-phase current
u
for direct current and single
2 OP(mm2)
phase alternative current
q=
uU
of known power
for three-phase current
O P(mm2)
q=
u U
Voltage drop
For low voltage cable network of normal operation, it is
advisable of a voltage drop of 3-5%.
On exceptional case, higher values (up to 7%) can be permitted
in case of network-extension or in short-circuit.

for direct current


of known current
for single phase
alternative current
for three-phase current

for direct current


of known power

u
U
P
Rw
L
L

2 ,O(v)
q
2 ,FRV O
u=
(v)
q

u = 1,732 ,FRV O(v)
q

u=

u=

2 OP(v)
qU
2 OP
(v)
qU
OP(v)
qU

for single phase


alternative current

u=

for three-phase current

u=

= voltage drop(V)
= operating voltage (V)
= power (W)
= effective resistance ()/km)
= Inductance (mH/km)
= induktiver Widerstand
(1)/km) ( = 2 f
at 50 Hz = 314)

q = cross-section (mm2)
, = working current (A = Ampere)
O = length of the line
in m
(Kappa) = electrical conductivity
of conductors (m/1 mm2)
-copper : 58
-Alu
: 33

Nominal voltage
The nominal voltage is to be expressed with two values of
alternative current U0/U in V (Volt).
U0 /U = phase-to-earth voltage
: Voltage between conductor and earth or metallic
U0
covering (shields, armouring, concentric conductor)
U
: Voltage between two outer conductors
U0
: U/
3 for three-phase current systems
U0
: U/2 for single-phase and direct current systems
U0/U0 : an outer conductor is earth-connected for A. C.- and
Nominal current

Phase angle
is a phase angle between voltage and current
cos = 1,0 0,9 0,8 0,7 0,6 0,5
sin = 0 0,44 0,6 0,71 0,8 0,87
Insulation resistance
Siso In Da 10 8 (M1 km)
Riso =
O
d
Specic Insulation resistance
O 108
Rs
= R 2 Da
In di
Da
d
di
l
Siso

=
=
=
=
=

outer diameter over insulation (mm)


conductor diameter (mm)
inner diameter of insulation (mm)
length of the line (m)
Spec. resistance of insulation materials (1 cm)

Mutual capacity (CB) for single-core,


three-core and H-cable)
r 103
CB =
(nF/km)
18 In Da
d
Inductance
Single-phase
three-phase

0,4 (In Da + 0,25) mH/km


r
Da
0,2 (In
+ 0,25) mH/km
r

Da

= distance - mid to mid


of both conductors
r
= radius of conductor (mm)
r
= dielectric constant
0,25 = factor for low frequency
Earth capacitance
EC = 0,6 CB
Charging current (only for three-phase current)
,Lad = U 2 f CB 106 A/km je Ader bei 50 Hz
Charging power
PLad = ,Lad U
Leakage and loss factor
G
= tan  C (S)
tan =

G
C


=
C
=
tan =
S
=

2f
Capacity
loss factor
Siemens = 1
11

Dielectric loss
Dv
= U2 2 f CB tan 106 (W/km)
f on 50 Hz
tan PE/VPE cables
0,0005
EPR
0,005
Paper-single core, three-core, H-cable 0,003
Oil-lled and pressure cable
0,003
PVC-cable
0,05

Active current
, in (A)
Reactive current
,w = , cos
Blindstrom
,0 = , sin
Apparent power (VA)
S=U,
S = 1,732 U ,

for single phase current (A. C.)


for three-phase current

Active power (W)


P = U , cos
P = 1,732 U , cos
P=U,

for single phase current (A. C.)


for three-phase current
for direct current

Reactive power (var)


Q = U , sin
Q = 1,732 U , sin
(Voltampere reactiv)

for single phase current (A. C.)


for three-phase current
Q = P tan

It should be noted that for the current load of the insulated


cables and wires of selected cross-section, the power ratings
table is also be considered.
To estimate the voltage drop of insulated wires and cables for
heavy (big) cross-sections of single- and three-phase-overhead
line, the active resistance as well as the inductive resistance
must be considered.
The formula for single-phase (A. C.):
U = 2 O , (Rw cos + L sin ) 103 (V)
Three-phase:
U = 1,732 O , (Rw cos + L sin ) 103 (V)

X 108
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Capacity of KTG-Pool drums


Flange-
Drum Barrel-
Bore-
Width over all
Width for windings

Wooden drums (standard)


Drumcode
numbers

Drumsize

Flange

Drum-Barrel

Bore

Width
over all

Width
for windings

Fd

Kd

Bd

I1

I2

mm

mm

mm

mm

mm

Load bearing Drum


capacity
weight
max.
kg

kg

051

05

500

150

56

470

410

100

061

06

630

315

56

415

315

250

17

071

07

710

355

80

520

400

250

25

081

08

800

400

80

520

400

400

31

091

09

900

450

80

690

560

750

47

101

10

1000

500

80

710

560

900

71

121

12

1250

630

80

890

670

1700

144

141

14

1400

710

80

890

670

2000

175

161

16/8

1600

800

80

1100

850

3000

280

181

18/10

1800

1000

100

1100

840

4000

380

201

20/12

2000

1250

100

1350

1045

5000

550

221

22/12

2240

1400

125

1450

1140

6000

710

250

25/14

2500

1400

125

1450

1140

7500

875

251

25/16

2500

1600

125

1450

1130

7500

900

281

28/18

2800

1800

140

1635

1280

10000

1175

Plastic drums
Drumcode
numbers

Flange

Fd
mm

Drum-Barrel

Kd

Width
over all
I1

Widthfor windings
I2

Load bearing
capacity
max.

Drum
weight
kg

mm

mm

mm

kg

050

500

150

456

404

100

070

710

355

510

400

250

15

080

800

400

510

400

350

16

090

900

450

680

560

400

23

100

1000

500

704

560

500

32

Bore

max.
Bd

Drum
weight

One-way wooden drums


Drumcode
numbers

Flange

Drum-Barrel

Width
over all

Widthfor windings

Fd

Kd

I1

I2

mm
HE 350

350

mm

mm

mm

mm

kg

150

320

300

56

1,8

HE 400

400

150

320

300

56

2,1

HE 401

400

150

425

405

56

2,3

HE 501

500

150

320

300

56

3,0

HE 500

500

150

425

405

56

3,3

HE 600

600

150

425

405

56

4,5

HE 760

760

300

425

400

80

8,0

X
X 109

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Cable lengths (m) to KTG-Drums

capacity of pool drums

Drum sizes and code numbers


Cable 1

D
mm
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92

051
05

061
06

071
07

081
08

1130
815
630
460
390
320
260
220
190
170
150
130
110
105
100
80

1110
840
640
470
388
315
254
238
190
180
140
134
102
96
92
90
65
62
60
58
56

2024
1480
1064
890
680
564
470
385
360
300
239
228
218
172
165
159
122
117
113
110
80
78
76
73
70

2755
2340
1463
1152
980
760
643
542
454
430
358
294
280
228
220
210
167
160
156
150
116
113
109
106
103
76
74
72

min. Drum-Barrel-  40 D
min. Drum-Barrel-  30 D
min. Drum-Barrel-  25 D
min. Drum-Barrel-  20 D
min. Drum-Barrel-  15 D

091
09
2730
2202
1768
1404
1206
1032
880
749
632
603
505
485
402
387
315
304
294
285
226
220
215
209
162
157
153
150
146
108
105
103

101
10

2866
2349
1910
1540
1339
1159
1000
860
736
705
599
576
485
468
389
377
365
299
290
282
226
220
214
209
204
158
154
150
148
144
110
105
102
100

121
12

2727
2265
1990
1756
1545
1355
1184
1139
990
856
827
709
688
668
567
550
462
450
438
428
352
344
336
329
265
259
254
249
244
190
187
183
180
177
174
130
127
125
123
120

141
14

2967
2480
2205
1960
1737
1535
1352
1304
1145
999
967
839
814
700
680
663
564
550
537
450
440
430
422
348
340
334
327
264
259
254
249
245
240
187
184
180
178
175
172
170
126
124
122
121
119
117

161
16/8

2722
2435
2172
1930
1870
1657
1608
1420
1244
1210
1180
1028
1003
866
846
828
710
692
678
664
560
549
539
529
437
430
422
415
408
330
325
319
314
310
305
230
235
232
228
225
222
220
216
160
158
156
154
152
150

181
18/10

2830
2527
2248
2172
1927
1867
1650
1450
1410
1370
1200
1166
1009
985
962
824
806
788
772
653
640
627
615
510
502
492
484
475
386
380
373
367
360
356
280
276
270
267
263
260
256
252
190
187
184
182
180
178
174
172
170
168
166
164
162
160
112
110
109
108
107
106
105
103

201
20/12

2954
2608
2522
2218
2150
1880
1826
1583
1540
1500
1289
1257
1227
1040
1017
994
972
812
795
779
763
750
610
600
589
578
568
558
442
435
428
420
414
408
400
304
300
295
290
287
282
280
275
270
266
264
186
184
182
180
177
175
173
170
168
166
164
163
161
158
156
155
154
152
150
149
147
146
144
90

221
22/14

2860
2777
2450
2383
2089
2035
1984
1726
1685
1646
1418
1386
1356
1328
1130
1107
1085
1065
890
874
858
842
828
878
666
655
644
634
624
614
488
480
473
466
460
453
448
440
335
330
326
320
317
313
310
305
300
297
294
291
287
284
281
278
196
194
192
190
188
186
184
182
180
178
176
175

250
25/14

2978
2908
2605
2547
2270
2223
1969
1930
1892
1664
1633
1603
1574
1373
1349
1326
1144
1125
1107
1089
1072
912
898
885
872
860
720
710
700
690
680
670
662
640
534
528
520
515
510
502
498
490
486
480
380
375
370
367
363
360
356
352
349
345
342
338
335
332
329
248
245

251
25/16

2976
2893
2558
2490
2428
2134
2083
2035
1774
1735
1697
1486
1435
1406
1199
1175
1153
1130
1110
930
914
898
883
869
715
700
690
680
668
658
649
640
610
500
494
487
480
474
468
462
456
450
342
338
334
330
326
322
318
314
310
306
304
300
297
294
290
288
285
202
200
198
196
194

281
28/18

2890
2820
2760
2432
2380
2330
2036
1995
1956
1692
1660
1630
1600
1366
1342
1320
1298
1276
1072
1056
1040
1022
1006
990
815
803
790
780
770
760
748
738
588
580
574
566
558
552
545
540
532
526
520
514
508
502
382
378
375
370
367
363
359
355
352
348
345
340

Cable 1

D
mm
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92

Kd = Drum-Barrel-
D = Cable-

X 110
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Explanatory notes on CE marking


Low Voltage Directive (NSR), EMC Legislation
The Manufacturers must have to identify those
products by the CE marking which fall within the
applicability of certain EC (European Community)
directives.
This applies to products which are covered by these
directives in accordance with the new concept to
include particular requirements on the technical
characteristics of products.
The realization of these requirements is the condition for marketing the products in Europe. Then
these CE directives constitute binding legislation for
the European Union.
The inclusion of the CE marking conrms the
compliance by the products with the basic requirements of all specications applicable to that product.
This means that CE marking is thus the compelling
requirement in order of placing the products on the
market within the EU. This also applies in the country
of manufacture.
These directives are only then binding when these
have been implemented in the national legislation
of individual EU member states. An implementation
in the national legislation of individual members
states does not always occurs at the same time and
is not always accomplished within the foreseen
period.
Furthermore, certain transition rules may apply. If
the obligation for implementation of these directives
is not met, then these directives can still be directly
applicable in certain circumstances.
The validity for these directives are not always
clearly formulated and are sometimes abstract and
not differentiated such that it cannot always be
unambiguously established whether a product is
covered by one or more directives and thus requires
the CE marking.
The CE marking serves as evidence to the supervisory authorities of compliance with these directives.
It is however often misinterpreted as being a
symbol for safety or quality which is why it is often
requested from customers without any legal justication.

EC Low Voltage Directive (NSR)


The EC Low Voltage Directive (NSR) is one of these
CE Designation Directives (Article 13 of the CE
Marking Directive). This means that electrical equipment used in low voltage range applications must
also be identied by the CE marking. The CE
marking is afxed on these products since
01.01.1997.

The CE Marking Directive will apply to a large


number of electrical products, alone on account of
the extensive range of applicability of the Low
Voltage (NSR) and Electromagnetic Compatibility
(EMC) Directives.
The following directives are of particular
signicance for the electrical industry:
2006/95/EG
73/23/EEC and 93/68/EEC
Electrical equipment for use within specied
voltage limits (Low Voltage Directive)
89/106/EEC
Construction products
89/336/EEC
Electromagnetic compatibility (EMC Directive)
89/392/EEC
Safety of machinery
91/263/EEC
Telecommunications terminal equipment
For HELUKABEL as manufacturer and supplier of
cables and wires, only the Low Voltage Directive is of
signicance. The EMC directive is of indirect applicability for customer enquiries in that queries
could arise regarding the immunity of cables to
interference, capacitance unbalance values and
similar characteristics.

The EMC Directive


The EMC Directive, which applies for the electromagnetic compatibility of electrical and electronic
equipment in their environments, can only be
applied in complete systems.
For example, systems which are made up of several
units, whereby each individual unit alone meet EMC
requirements, are tested as a system for EMC together with the interconnecting cables.
EMC testing of a single cable or a single wire cannot
be specied.
Title:
73/23/EEC and 93/68/EEC: Directive of the Council
dated February 19, 1973, for harmonisation of the
legislation in member states regarding electrical
equipment for use within specied voltage ranges
with amendments dated July 22, 1993.

Continuation 

X 111
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Explanatory notes on CE marking


Low Voltage Directive (NSR), EMC Legislation
Important information regarding the Low
Voltage Directive (NSR):

1. General Conditions:
a) The major characteristics required for knowledge and observance, for use in accordance
with the intended application, are given on the
electrical equipment, or, if this is not possible,
in the accompanying instructions.
b) The manufacturers symbol or trade mark shall
be clearly visible on the electrical equipment,
or, where this is not possible, shall be afxed
on the packaging.
c) The electrical devices as well as the components for these, shall be procured such that
these can be connected safely and properly.
d) The electrical equipment shall be designed
and constructed such that protection from the
hazards listed in item 2 and 3, is assured
during use and proper maintenance in accordance with the intended application.

2. Protection against hazards which may arise


from electrical equipment technical
measures shall be foreseen in accordance
with item 1, such that:
a) Humans and working animals are protected
from injury or other harm which can be caused
by either direct or indirect contact.
b) No high temperatures, arcs or radiation are
generated from which hazards could arise.
c) Humans, working animals and property are
adequately protected against non-electrical
hazards which, from experience, can arise from
electrical equipment.
d) The insulation complies to the property
requirements.

c) cannot endanger humans, working animals or


property in any way by the foreseen overloads.

Equipment and areas which do not fall within the


Directive.
Electrical equipment for use in explosive
atmospheres
Electrical-radiological and electrical medical
equipment
Electrical components of passenger and goods
lifts
Electricity meters, household plug-in xtures,
radio interference suppression devices
Installation for supplying power to electried
pasture fencing
Specied electrical equipment intended for use
on ships, in aircraft or railways and which comply
with the safety regulations of member states for
international installations.
Electrical equipment within the context of the Low
Voltage Directive is electrical equipment for applications with a rated voltage between 50 and 1000 V
alternating current and between 75 and 1500 V
direct current.
For a more exact interpretation of the Directive,
cables and wires are covered by the regulation, not
however cables with a rated voltage exceeding
1000 V alternating current or 1500 V direct current.
HELUKABEL as manufacturer and supplier must act
in accordance with the Low Voltage Directive, that is
to say:
Cables and wires up to 1000 V nominal voltage
must be identied by the CE marking, refer to
page X 111.
The identication can be attached either to the
product or on the label.

3. Protection against hazards which can arise


from external inuences on electrical equipment technical measures are foreseen in
accordance with item 1, such that the electrical equipment:
a) can withstand the mechanical loads such that
humans, working animals or property are not
endangered.
b) can withstand the non-mechanical effects
under foreseen environmental conditions such
that humans, working animals or property are
not endangered.
X 112
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

European Directives WEEE, RoHS and ElektroG


The European Union has approved directives with
a view to protecting man and environment. The
member states have made these directives into
national law.

Directives and Laws


WEEE
Waste Electrical and Electronic Equipment
Directive 2002/96/EC of the European Parliament and
the Council on used electrical and electronic devices
dated January 27, 2003
Aim:
To attain a consistent level of health and
environmental protection throughout the member
states.
To harmonise the responsibility held by the
manufacturers.
To attain equivalent participation by the traders.
The member states are to employ suitable measures
for ensuring that used electrical and electronic devices
are treated in such a way as to prevent their entry
into the waste stream. They are to set out regulations
for the dismantling, reuse and recycling of these
devices.

Scope:
This Act applies for all electrical and electronic devices
that fall under certain categories, insofar as they are
not part of another device not covered by the scope
of this Act.
Orientation aid
Requires electrical current to full
its primary function?

No

Product is not governed


by the ElektroG

Yes

Product is not governed


by the ElektroG

Yes

Product is not governed


by the ElektroG

No

Product is not governed


by the ElektroG

Yes

Product is not governed


by the ElektroG

Yes
Working voltage greater than 1000 VAC
or greater than 1500 VDC
No
Does the component have an
independent function?
No
Does the device fall under one of the
10 categories of the ElektroG?
Yes
Is the device used for military purposes
or to protect signicant safety
interests?
(Are the components lamps in
households or lament bulbs?)
Is the component a xed-location,
large-scale industrial tool or part of
a xed-location system?
Is it a medical product that is
implanted or infectious?
Do other legal regulations
(e.g. used vehicle regulation nor
battery provision) apply?
No

RoHS
Restriction of Hazardous Substances in electric and
electronic equipment
Directive 2002/95/EC of the European Parliament and
the Council on restriction of use of certain hazardous
substances in electrical and electronic equipment
dated January 27, 2003.
Aim:
To reconcile the legal regulations of the member
states on restriction of use of hazardous substances
and electrical and electronic equipment.
Substance bans and restrictions.
The member states guarantee that from July 1, 2006, use
of the following substances in electrical and electronic
equipment will be restricted:
Lead, Mercury, Cadmium, Chromium VI
Polybrominated biphenyl (PBB)
Polybrominated diphenylether (PBDE)
Law on the use, return and environmentallycompatible disposal of electrical and electronic
equipment.
ElektroG (Electrical and Electronic Equipment Act) of
March 16, 2005.
This Act enforces the EU Directives 2002/96/EC and
2002/95/EC.
Aims:
To avoid electrical and electronic equipment
waste.
To reuse and/or recycle the materials from this
waste.

Product is governed by the ElektroG!

Substance bans
5 from ElektroG (RoHS)
It is forbidden to bring into circulation new
electrical and electronic devices containing more
than 0.1 percent by weight of lead, mercury,
hexavalent chromium, polybrominated biphenyl
(PBB) or polybrominated diphenylether (PBDE) for
each homogenous material or more than 0.01
percentage by weight of cadmium per homogenous
material. Clause 1 does not apply for category 8 and 9
electrical and electronic devices nor for electrical and
electronic devices brought into a member state of
the European Union for the rst time before July 1,
2006. Nor does it apply for spare parts for the repair
or reuse of electrical and electronic devices brought
into circulation for the rst time before July 1, 2006.
Denition
The majority of our products are not governed by the
ElektroG (WEEE/RoHS), as they do not have an
independent function. As the possibility of our
customers using our products in devices that are
governed by the ElektroG, and as such are declarable,
cannot be ruled out, we have decided to mark in this
catalogue the products that either comply with the
limit values indicated in accordance with ElektroG
(WEEE/RoHS) 5 and/or do not infringe provisions of
the ElektroG (WEEE/RoHS).
X 113

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Glossary of Therms: Cables and Wires


Types

Page

Types

Page

2YSLCY-J (TOPFLEX-EMV)

D 21 - D 22

Breakout-Cable (LWL)

R 7, R 41 - R 44

2YSLCYK-J (TOPFLEX-EMV-UV)

D 23 - D 24

British Standard

N 154 - N 157

400 Hz

T 49 - T 50

BUS Cables
DESINA-HYBRID-BUS

R 114

A
F8

BUS Cables
Multibus-Cable

R 145 - R 146

A07 RN-F
A-2Y(L)2Y

P4

BUS Cables A-BUS EPDM

R 147

A-2YF(L)2Y

P5

BUS Cables AS-Interface

R 151

A-DF(ZN) 2Y

R 24

R 155

A-DF(ZN)2Y4Y

R 26

BUS Cables Belden


DeviceNetTM CPE

A-DF(ZN)B2Y

R 25

BUS Cables CAN Bus

R 132 - R 141

A-DQ(ZN)2Y

R 17 - R 18

BUS Cables CC-Link BUS

R 157

A-DQ(ZN)B2Y

R 19

BUS Cables DeviceNetTM

R 153 - R 154,
R 156

A-DQ(ZN)B2Y,
brecombi MM+SM

R 23

BUS Cables E-BUS

R 160 - R 162

A-DSF(L)(ZN)2Y

R 32

BUS Cables FOUNDATION

R 122 - R 125

Aerial Fibre Optic Cable (LWL)

R 33

BUS Cables HMCB

R 126 - R 129

Aircraft lifter-T

T 13

BUS Cables I-Bus

R 142 - R 144

AIRPORT 400 Hz

T 49 - T 50

BUS Cables KH-BUS

R 163

A-LiY(StE)Y

Q 20

BUS Cables LON BUS

R 159

ASI-Bus

R 147 - R 150

BUS Cables Probus


ET200X + ECOFAST

R 112

Audio-Cable, analogue

S4-S8

BUS Cables Probus L2

Audio-Cable, digital

S 9 - S 12

R 107 - R 111,
R 115

BUS Cables Probus PA

R 116 - R 118

B
BAM

Q 19 - Q 20

BUS Cables Probus SHIPLINE

R 113

BAULIFTKABEL B101 / B102 / B103

T 14

BUS Cables Probus SK

R 119 - R 121

Bell Sheathed Cables

O4

BUS Cables SafetyBUS

R 158

BIOFLEX-500 -JZ

A 84

BUS Cables SENSOR-AKTOR

R 152

BIOFLEX-500 -JZ-C

A 85 - A 86

BUS Cables USB

R 130 - R131

BIOFLEX-500-JZ-HF

C 26

BUS Cables WK CAN Bus 105

R 134

BIOFLEX-500-JZ-HF-C

C 27 - C 28

Bio-oil-resistant

A 84 - A 86
C 26 - C 27

C.N.O.M.O

N 16

Cables CAN

R 132 - R 141

Blue outer jacket

A 49 - A 50,
A 58 - A 59,
A 80 - A 82, B 26,
B 28 - B 29,
B 31 - B 32

Cables for AS-INTERFACE

R 151

Cables for Bussystems

R 89 - R 163

Cables for EIB

R 160 - R 162

Cables for INTERBUS

R 142 - R 144

Cables for PROFIBUS

R 107 - R 121

Breakout-Cable (LWL)

R 9, R 12 - R 33,
R 45

X 114
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Glossary of Therms: Cables and Wires


Types

Page

Types

Page

CAN (Controller Area Network)

R 132 - R 141

DeviceNet PUR

R 156

CAN-Bus 0,22 mm2

R 132

DeviceNet PVC

R 153

CAN-Bus 0,25 mm2

R 140

DMX + Power

S 17

CAN-Bus 0,34 mm2

R 135

DMX Cable

S 13 - S 17

CAN-Bus 0,50 mm2

R 137

Drag chain Cables

CAT.5 100 MHz

R 54 - R 64,
R 91 - R 97

C 5 - C 35, D 9,
D 11, D 15, D 17,
N 82 - N 106,
T 46 - T 47

CAT.6 250 MHz

R 66 - R 67

DREINORM

N 111 - N 112

CAT.7 600 MHz

R 71 - R 76, R 89

Drinking water

I4-I5

CATV-Cables

M8

CCC

prex page 18

CC-Link-Bus

R 157

CEE-Extensions

U 62

CEI 20-22

N 15

Cheapernet

R 85

Clean Room Qualied Cable

prex page 19

COAXIAL-Cable

M 4 - M 12, S 27

COAXIAL-Cable RG

M4-M7

COAXIAL-Cable RGB
transmission cables

M 12

COAXIAL-Cable SAT

E
E 30

Q 31 - Q 38

E 90

Q 39 - Q 46

Earth Conductors

Q 6 - Q 22

Earth Conductors ESUY and ESY

K 33

EDV-PiMF-CY

B 25

EIB-Bus

R 160 - R 161

EIB-Bus 4-pairs PVC

R 161

ETHERNET LAN-Cable

R 54 - R 85

EWKF

E 9, E 19

M9

Extensions / Supply Cables

U 59, U 62

Command Cable UL (LiYCY)

N 69 - N 71

Command Cable UL (LiYCY-TP)

N 72 - N 73

F-C-PUR-JZ

A 54 - A 55

Command Cable UL (LiYY)

N 65 - N 66

F-CY-JZ

A 27 - A 28

Command Cable UL (LiYY-TP))

N 67 - N 69

F-CY-OZ (LiY-CY)

A 25 - A 26

Compensating Cables

L 2 - L 12

Feedback Cable

Compensating Cables for


thermo elements

D 13 - D 16,
N 135 - N 136

L 6 - L 12

FEP 6Y (HELUFLON)

E 11 - E 12

Computer Cable

B 28 - B 29

Fibre Optic Cables (LWL)

R 6 - R 47

CSA, see selection table

prex page 28

Fire warning Cable

P8

Fire warning Cable halogen-free

P 11, Q 29 - Q 30,
T 35

FIVENORM

N 113 - N 114

Flat Cables

J 4 - J 10

FLRY (Vehicle Cable)

K 44

FLY (Vehicle Cable)

K 41 - K 43

FMGCG (Ships Telephone Cables)

W7

FMGCH (Ships Telephone Cables)

W7

D
DATAFLAMM

B8

DATAFLAMM-C

B 23

DATAFLAMM-C-PAAR

B 24

DATAPUR-C

B 22

DESINA, see selection table

prex page 21

DeviceNet Belden

R 155

DeviceNet FRNC

R 154

X
X 115
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Glossary of Therms: Cables and Wires


Types

Page

Types

Page

FOUNDATION Fieldbus FF Type A

R 123 - R 125

H07 V-R

K 11

Frequency converters

D 17 - D 24

H07ZZ-F

F 12 - F 13

Front connecting Cables


for Simatic S7

U 63

halogen-free

prex page 27

Heavy duty Cable

S 28

FROR CEI 20-22 II

N 15

Heavy duty rubber Cable

F 14

Functionality E30/E90

Q 31 - Q 46
K 26

HELUCOM pact LWL-outside Cable


A-DQ(ZN)B2Y, central

R 19

FZ-LSi / FZ-LS / Neon Light Cables

HELUCOM pact LWL-universal Cable


A/IDQ(ZN)BH

R 11

HELUCOM pact LWL-universal Cable


A/IDQ(ZN)BH OM3

R 12

HELUFLON -FEP-6Y

E 11 - E 12,
K 27

G
GALVANICABLE

T 11

GOST

prex page 28

H
H01N2-D/-E

K 34

H03VV-F

A 18

HELUFLON -PTEF-5Y

K 28

H05 BQ-F / H07 BQ-F (NGMH11Y)

A 48

HELUKABEL BS 5308-1

N 154

H05 RR-F / H05 RN-F

F5

HELUKABEL BS 5308-2

N 155

H05 V2-K

K 19

HELUKABEL BS 5467

N 156

H05 V-K

K6-K7

HELUKABEL BS 6724

N 157

H05 V-K / (H)07 V-K**

K 12

HELUKAT 100 FTP ex

R 59

H05 V-K, H07 V-K

K 13

HELUKAT 100 UTP ex

R 57

H05 V-U / (H)05 V-U / (H)07 V-U

K 10

HELUKAT 1200 S-STP duplex massive

R 80

H05G-U / -K/ H07G-U / -R / -K

K 18

HELUKAT 1200 S-STP massive

R 79

H05SS-F / H05SST-F

E 10

HELUKAT 155 FTP massive

R 58

H05VV5-F (NYSLY-JZ)

A 11 - A 12

HELUKAT 155 UTP massive

R 54

H05VVC4V5-K (NYSLYCY-JZ)

A 29 - A 30

HELUKAT 200 S-FTP duplex massive

R 63

H05VV-F

A 19 - A 20

HELUKAT 200 S-FTP ex

R 64

H05VV-F/SJT

N 12 - N 13

HELUKAT 200 S-FTP massive

R 62

H05VV-F/UL

N 14
HELUKAT 450 S-STP duplex massive

R 67

(H)03 Z1Z1-F

A 69

(H)05 Z1Z1-F

A 70

HELUKAT 450 S-STP massive

R 66

(H)05VV5-F ((N) YSLY-JZ)

A 13 - A 14

HELUKAT 600 S-STP duplex massive

R 72

(H)05VVC4V5-K ((N)YSLYCY-JZ

A 31

HELUKAT 600 S-STP ex

R 73

H05VVH6-F

J4

HELUKAT 600 S-STP massive

R 71

H05Z-K / H07Z-K

K 16 - K 17

HELUKAT 600A S-STP massive out

R 74

H07 RN8-F

I6-I7

HELULIGHT

S 1 - S 31

H07 RN-F

F6-F7

HELUSOUND

S 1 - S 31

H07 V2-K

K 21

HELUSOUND 500 PUR

S 25

H07 V-K / (H)07 V-K

K8-K9

HELUSOUND 600 FRNC

S 26

X 116
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Glossary of Therms: Cables and Wires


Types

Page

Types

Page

HELUSPEADER

G8

R 99

HELUTHERM 120

E4

Industrial Ethernet 100T S-FTP


TORDIERFLEX

HELUTHERM 1200 / 1200-ES

K 32

Industrial Ethernet 200IND S-FTP


MEGAFLEX

R 94

HELUTHERM 125-J/-O

K 20

R 98

HELUTHERM 145

K 22 - K 23,
N 117 - N 118

Industrial Ethernet 200S S-FTP


4-CORE Drag Chain
Industrial Ethernet 200S S-FTP
4-PAIR Drag Chain

R 100

Industrial Ethernet 250S S-FTP


Drag Chain

R 93

Industrial Ethernet 600IND S-STP


Shipline

R 90

Industrial Ethernet 600IND S-SPT


ROBUST

R 89

Industrial Ethernet 600IND S-SPT


ROBUST UL

R 91

Industrial Ethernet PROFinet B


SHIPLINE

R 104

Industrial Ethernet PROFinet C


Torsion

R 106

HELUTHERM 145 MULTI

E5-E6

HELUTHERM 145 MULTI-C

E 14 - E 15

HELUTHERM 400

K 29

HELUTHERM 600 / 600-ES

K 30

HELUTHERM 800 / 800-ES

K 31

HELUTRAIN 3GKW

K 39

HELUTRAIN 4GKW

K 40

HELUTRUCK 270

T 52

HELUTRUCK 271

T 53

HELUTRUCK 272 / 273

T 54

HELUWIND Thermex 145

T 39
T 35

Industrial Ethernet PROFInet type A


Cat. 6a

R 92

HELUWIND WK
re warning Cable Torsion

T 34

Industrial Ethernet PROFlnet


type B + C

R 105

HELUWIND WK 101 H
HELUWIND WK 103k EMV D-T

T 28

R 102

HELUWIND WK 103w EMV D-T

T 27

Industrial Ethernet PROFlnet type A,


radiation resistant + sheated

HELUWIND WK 135-Torsion

T 29

Industrial Ethernet PROFlnet type A,


standard und robust

R 101

HELUWIND WK 137-Torsion

T 30
T 31

Industrial Ethernet PROFlnet type B


hybride

R 103

HELUWIND WK 300w-Torsion
HELUWIND WK 305-Torsion

T 32

Industrial Ethernet WK 105

R 95

HELUWIND WK DLO 2kV

T 37

Industrial electronic

B 31 - B 33

HELUWIND WK H07BN4N4-F
WIND-Torison

T 33

Industrial Cable (LWL)

R 39 - R 45

Installation Cable halogen-free

HELUWIND WK Powerline ALU

T 38

P 10 - P 11,
O7-O9

HELUWIND WK-NTSCGEWOEU-Torsion T 36

Installation Cable J-2Y(ST)Y...ST III BD

P 12

High voltage igniton Cables

Installation Cable/re warning Cable


halogen-free

P 10 - P 11,
Q 29 - Q 30, T 35

Installation manual

prex page 36

Instrument Cable

S 18,
N 156 - N 157

Instrumentation Cable

B 26 - B 27, B 34

Insulation integrity FE180

Q 28 - Q 46

K 26

I
IBM Typ 1A

R 83

Industrial Ethernet 100S S-FTP


4-CORE Drag Chain ECO

R 96

Industrial Ethernet 100S S-FTP


4-PAIR Drag Chain ECO

R 97

X
X 117
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Glossary of Therms: Cables and Wires


Types

Page

Types

Page

INTERBUS

R 142 - R 144

JZ-600 HMH

A 66 - A 67

Interbus drag chain

R 144

JZ-600 HMH-C

A 75 - A 76

Interbus xed installation

R 142 - R 144

JZ-600 PUR

N 49 - N 50

Intrinsically safe circuits,


data Cables

B 26, B 28 - B 29,
B 31 - B 32

JZ-600 UL/CSA

N 10 - N 11

JZ-600-YC-PUR

N 52 - N 53

Intrinsically safe circuits,


exible Cables

A 49 - A 50
A 58 - A 59
A 80 - A 82

JZ-600-Y-CY

A 36 - A 37

JZ-600-Y-CY UL/CSA

N 20 - N 21

JZ-602

N7-N8

J
J-2Y(St)H

P 12

JZ-602 RC*

N3

J-2Y(St)Y

B 30

JZ-602 RC* -C-PUR

N 91

JB-500

A 21

JZ-602 RC* -CY

N 85

JB-750

A 22

JZ-602 RC* -PUR

N 86

JB-750 HMH

A 68

JZ-602-C-PUR

N 51

JB-750 HMH-C

A 77 - A 78

JZ-602-CY

N 17 - N 18

JB-750 yellow

A 23

JZ-602-PUR

N 46 - N 47

JE-H(St)H

Q 28 - Q 29

JZ-602-PUR DC/AC

N 48

JE-H(St)HRH

Q 30

JZ-603

N9

JE-LiHCH

B 33

JZ-603-CY

N 19

JE-LiYCY

B 32

JZ-HF

C5-C6

JE-Y(St)Y

B 31

JZ-HF-CY

C8-C9

J-H(St)H

P 10 - P 11

Jumper wire

O4

KH-Bus

R 163

J-Y(St)Y Lg

P7-P8

KOMPOFLEX JZ-500

A 87

J-YY Bd

P6

KOMPOFLEX JZ-500-C

A 88

JZ 500-FC-PUR

A 52 - A 53

KOMPOSPEED 600 / 600-C

K 37

JZ 604 TC TRAY Cable

N 25 - N 26

KOMPOSPEED JZ-HF-500

C 29

JZ 604-FCY TC TRAY Cable

N 33

KOMPOSPEED JZ-HF-500-C

C 30

JZ 604-YCY TC TRAY Cable

N 34

JZ-500

A6-A7

LAN-Cable for structured cabling

R 54 - R 85

JZ-500 black

A9

LAN-Cable 100 UPT ex

R 57

JZ-500 C black

A 24

LAN-Cable 1000 S-STP

R 77

JZ-500 COLD

A8

LAN-Cable 1000 S-STP duplex

R 78

JZ-500 HMH

A 62 - A 63

LAN-Cable 1200 S-STP

R 79

JZ-500 HMH-C

A 71 - A 72

LAN-Cable 1200 S-STP duplex

R 80

JZ-500 orange

A 10

LAN-Cable 155 FTP

R 58

JZ-500 PUR

A 43

LAN-Cable 155 UPT

R 54

JZ-600

A 16 - A 17

LAN-Cable 155 UPT UL

R 55

X 118
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Glossary of Therms: Cables and Wires


Types

Page

Types

Page

LAN-Cable 200 FTP ex UL

R 61

W 10

LAN-Cable 200 S-FPT ex

R 64

Light Marine Telecommunication


Cables LFMGSSGO

LAN-Cable 200 S-FTP

R 62

Light Marine Telecommunication


Cables XLFMKK

W5

LAN-Cable 200 S-FTP duplex

R 63

W 11

LAN-Cable 300 UPT UL

R 56

Light Marine Telecommunication


Cables LFMSGSSGO

LAN-Cable 300 U-SPT UL

R 65

LiY

K4

LAN-Cable 450 S-STP

R 66

LiYCY (F-CY-OZ)

A 25 - A 26

LAN-Cable 450 S-STP duplex

R 67

LiYCY (TRONIC-CY)

B 9 - B 10

LAN-Cable 500 S-STP duplex

R 69

LiYCY (UL)

N 69 - N 71

LAN-Cable 500 S-STP ex

R 70

LiYCY-CY (PAAR-TRONIC-CY-CY)

B 14 - B 15

LAN-Cable 500 S-STP simplex

R 68

LiYCY-TP (UL)

N 72 - N 73

LAN-Cable 600 S-STP

R 71

LiY-TPC-Y

B 21

LAN-Cable 600 S-STP duplex

R 72

LiYW / H05 V2-K

K 19

LAN-Cable 600 S-STP ex

R 73

LiYY (TRONIC)

B4-B5

LAN-Cable ETHERNET Cheapernet


Cable, Yellow Cable, Transceiver Cable

R 85

LiYY (UL)

N 65 - N 66

LiYY-TP (UL)

N 67 - N 68

LAN-Cable for outdoor use


600A S-STP PVC/PVC

R 74

LMGSGO (Marine Power Cables)

W6

Loudspeaker Cables

S 22 - S 27

LAN-Cable for outdoor use


600AE S-STP FRNC/PE

R 76

LAN-Cable for outdoor use


600E S-STP PVC

R 75

LAN-Cable IVS IBM P/N 33G2772,


IBM P/N 33G8224, IBM P/N 33G2775

R 84

LAN-Cable TWINAX IBM P/N 7 362 211

R 83

LAN-Cable 100 FE 60 F-FTP

R 60

LAN-Cable 100 FTP ex

R 59

LAN-Cable for ETHERNET-systems

R 54 - R 85

LAN-Cable for IBM-systems

R 83 - R 84

LAN type 1A

R 84

LAN type Twinax

R 83

Li-2YCYv

B 16

LIFT- 2S

F 11

Lift hoist control Cable

F 10 - F 11, T 14

LIFT-TRAGO-30 / -60

F 10

LifY Single Core

K 14

LifYCY

B 18

Light + Power

S 16

Loudspeaker Cables HELUSOUND 400 S 23


Loudspeaker Cables round

S 24

Low torsion

C 7, C 10, C 16,
C 21 - C 24, N 82,
N 84, N 89 - N 90,
N 94 - N 99

LWL-Aerial Fibre Optic Cable


metall free, ADSS

R 33

LWL-Cable outdoor, A-DQ(ZN)B2Y,


bre combi, stranded

R 23

LWL-Cable outdoor, A-DQ(ZN)SR2Y

R 29

LWL-Cable outdoor, A-DSQ(ZN)B2Y

R 31

LWL-Cable

R 6 - R 47

LWL-Cable bundle core, I-D(ZN)H

R9

LWL-Cable outdoor, divisible


AT-V(ZN)HH(BN)2Y

R 38

LWL-Fibre Optic Breakout Cable exible R 43


HCS AT-V(ZN)HH
LWL-Fibre Optic Breakout Cable robust R 42
HCS AT-VQH(ZN)B2Y
LWL-Fibre Optic Breakout Cable robust R 44
HCS A/IDQ(ZN)BH, exible

X
X 119
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Glossary of Therms: Cables and Wires


Types

Page

Types

Page

LWL-Fibre Optic Breakout Cable robust, R 44


exible, HCS I-V(ZN)YY

LWL-Fibre Optic Outdoor Cable


A-DF(ZN)2Y4Y

R 26

LWL-Fibre Optic Breakout Cable robust, R 41


exible, HCS I-V(ZN)Y11Y

LWL-Fibre Optic Outdoor Cable


A-DF(ZN)B2Y

R 25

LWL-Fibre Optic Breakout-Cable


I-V(ZN)HH

R7

LWL-Fibre Optic Outdoor Cable


acc DIN VDE 0888

R 22

LWL-Fibre Optic Cable


mobile, exible A-V(ZN)YY

R 35

LWL-Fibre Optic Outdoor Cable


A-DQ(ZN)2Y, stranded

R 18

LWL-Fibre Optic Cable exible


WK - mobile A-V(ZN)11Y

R 34

LWL-Fibre Optic Outdoor Cable


A-DQ(ZN)B2Y, stranded

R 21

LWL-Fibre Optic Cable exible


AT-V(ZN)H(ZN)11Y, AT-V(ZN)Y(ZN)Y

R 36

LWL-Fibre Optic Outdoor Cable


Microduct, A-DQ2Y, stranded

R 28

LWL-Fibre Optic Cable exible


AT-V(ZN)YY

R 37

LWL-Fibre Optic Outdoor Cable Hybrid R 32


A-DSF(L)(ZN)2Y

LWL-Fibre Optic Cable exible HCS


I-VH, I-VHH

R 40

LWL-Fibre Optic Cable Industry

R 40 - R 45

LWL-Fibre Optic Cable robust AT-VYY

R 39

LWL-Fibre Optic Cable with


AI-D(ZN)BH(SR)H E90

R 16

LWL-Fibre Optic Cable with


Functionality, A-DQ(ZN)BH E30

R 15

LWL-Fibre Optic Indoor Cable

R9

LWL-Fibre Optic Indoor Cable


I-VH, I-V11Y, I-VHH, I-V11Y11Y

R6

Marine Cables

W 4 - W 6,
W 8 - W 11

Marine Power Cables LMGSGO

W6

Marine Power Cables MGSGO

W4

Marine Telecommunication
Cables FMGSGO

W8

Marine Telecommunication
Cables FMSGSGO 250 V

W9

Marine Telecommunication

W 8 - W 11

MAXI-TERMI-POINT

B 17, B 26 - B 27

MCHU (NEO-at-C)

J7

Medium voltage power Cables

Q 47 - Q 62

LWL-Fibre Optic Indoor/Outdoor Cable R 14


A/IDQ(ZN)BH, stranded

MEGAFLEX 500

A 64 - A 65,
N 54 - N 55

LWL-Fibre Optic Indoor/Outdoor Cable R 13


A/IDQ(ZN)B, central

MEGAFLEX 500-C

A 73 - A 74,
N 56 - N 57

LWL-Fibre Optic Minibreakout Cable


I-V(ZN)H

R8

MEGAFLEX 600

N 58 - N 59

LWL-Fibre Optic Outdoor Cable

R 17 - R 32

MEGAFLEX 600-C

N 60 -N 61

LWL-Fibre Optic Outdoor Cable


A-DQ(ZN)2Y, central

R 17

MGSGO (Marine Power Cables)

W4

Microphone Cable

S 19 - S 21

LWL-Fibre Optic Outdoor Cable


A-DQ(ZN)B2Y, central

R 20

Minibreakout-Cable (LWL)

R 8, R 10

Mobile Cable (LWL)

R 34 - R 35

LWL-Fibre Optic Outdoor Cable


Microduct, A-DQ2Y, central

R 27

MPRX (Ships Power Cables)

W 14

LWL-Fibre Optic Outdoor Cable


A-DF(ZN)2Y

R 24

MPRXCX (Ships Power Cables)

W 15

MULTIFLEX 512-C-PUR

C 19 - C 20

LWL-Fibre Optic Outdoor Cable


A-DF(ZN)2Y(SR)2Y

R 30

MULTIFLEX 512-C-PUR UL/CSA

N 92 - N 93

MULTIFLEX 512-PUR

C 14 - C 15

LWL-Fibre Optic Indoor/Outdoor Cable R 10


A/I-VQ(ZN)BH

X 120
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Glossary of Therms: Cables and Wires


Types

Page

Types

Page

MULTIFLEX 512-PUR UL/CSA

N 87 - N 88

N2XS(F)2Y 6/10kV, 12/20kV, 18/30kV

Q 58 - Q 59

MULTIFLEX 600

N 62

N2XS2Y 6/10kV, 12/20kV, 18/30kV

Q 54 - Q 55

MULTIFLEX 600-C

N 63

N2XSEY 3 x 6/10kV

Q 62

Multimedia-Coaxial-Cable

M 10

N2XSY 6/10kV, 12/20kV, 18/30kV

Q 50 - Q 51

Multimedia-Kabel 1500 S-STP

R 81

N2XY

Q8

Multimedia-Kabel 1500 S-STP


duplex

R 82

NA2XS(F)2Y 6/10kV, 12/20kV, 18/30kV

Q 60 - Q 61

NA2XS2Y 6/10kV, 12/20kV, 18/30kV

Q 56 - Q 57

MULTISPEED 500-C-PUR

C 21

MULTISPEED 500-C-PUR UL/CSA

N 94 - N 95

NA2XSY 6/10kV, 12/20kV, 18/30kV

Q 52 - Q 53

MULTISPEED 500-C-PVC

C 10

NA2XY

Q 11

MULTISPEED 500-C-PVC UL/CSA

N 84

NANOFLEX HC 500

A 91

MULTISPEED 500-C-TPE

C 24

NANOFLEX HC 500-C

A 92

MULTISPEED 500-C-TPE UL/CSA

N 98 - N 99

NANOFLEX HC TRONIC

A 93

MULTISPEED 500-PUR

C 16

NANOFLEX HC TRONIC-C

A 95 - A 96

MULTISPEED 500-PUR UL/CSA

N 89 - N 90

NAYCWY

Q 18

MULTISPEED 500-PVC

C7

NAYY-J

Q 9 - Q 10

MULTISPEED 500-PVC UL/CSA

N 82

NEO-at

J5

MULTISPEED 500-TPE

C 22 - C 23

NEO-at-C

J7

MULTISPEED 500-TPE UL/CSA

N 96 - N 97

Neon Light Cables

K 26

MULTISPEED 600-C-PUR -J/-O

N 125

NEOPREN Command Cable

F9

MULTISPEED 600-PUR -J/-O

N 124

NFPA 79

N 25 ff

MULTISPEED TRONIC-C-PUR

N 106

NGFLGU (NEO-at)

J5

MULTISPEED TRONIC-PUR

N 105

NHMH-J

O8

MULTITHERM 400 -ES

E 20

NHMH-O

O7

MULTITHERM 400

E 13

NHXCH-FE 180/E 30

Q 37 - Q 38

NHXCH-FE 180/E 90

Q 45 - Q 46

NHXH-FE 180/E 30

Q 35 - Q 36

NHXH-FE 180/E 90

Q 43 - Q 44

N
(N)SHTU-V

G7

(N)TSCGEWu

G9

(N)YM(St)-J PVC-Sheathed Cable

O6

NHXHM-O/-J

O9

(N)YY-J (Petrol Station Cable)

Q 20

NSGAFU 3kV

K 35

N07RN-F/SOOW

N 80

NSHTU

G6

N2HX

Q 24 - Q 25

NSHXAF 3kV

K 36

N2XCH

Q 26 - Q 27

NSSHU

F 14

N2XCH-FE 180/E 30

Q 33 - Q 34

NYCWY

Q 16 - Q 17

N2XCH-FE 180/E 90

Q 41 - Q 42

NYCY

Q 12 - Q 13

N2XCY

Q 14 - Q 15

NYKY-J 0,6/1kV

Q 21 - Q 22

N2XH-FE 180/E 30

Q 31 - Q 32

NYM-J/-O PVC-Sheated Cable

O5

N2XH-FE 180/E 90

Q 39 - Q 40

NYY-J und NYY-O

Q6-Q7

X
X 121

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Glossary of Therms: Cables and Wires


Types

Page

Types

Page

PUR-spiral Cables orange

V7-V8

OB-BL-PAAR-CY

A 82

PUR-YELLOW

A 47

OZ-BL

A 80

PVC-Connecting Cables

U 58

OZ-BL-CY

A 81

PVC-at
(H05 VVH6-F/H07 VVH6-F)

J4

PVC-at-CY

J6

PVC-Single Core

K 6 - K 11, K 19,
K 21, N 116

PVC-Spiral Cable

V4

P
PAAR-CY-OZ

B 13

PAAR-TRONIC

B6-B7

PAAR-TRONIC-CY

B 11 - B 12

PAAR-TRONIC-CY-CY (LiYCY-CY)

B 14 - B 15

PAAR-TRONIC-Li-2YCY / -Li-2YCYv

B 16

Patch Cable: preassembled

Catalogue DNB

Petrol Station Cable

Q 20

Petrol-resistant

Q 19 - Q 22

PiMF

B 25, B 29

Pitch

J 9 - J 10

Plastic-bre Cable industry

R 46 - R 47

Power Cables

N 25 - N 26
N 33 - N 34
N 156 - N 157
Q 24 - Q 27

Pre-assembled Cables

chapter U

Probus ET200X

R 112

Probus Hybrid

R 103

Probus L2

R 107 - R 111

Probus PA

R 116 - R 118

Probus SK

R 119 - R 121

PTFE 5Y (HELUFLON)

K 28

PUR-750

A 51

PUR-connecting Cables orange

U 61

PUR-C-PUR

A 60

PUR-electronic spiral Cables

V 9 - V 10

PUR-electronic spiral Cables screened

V 11 - V 12

PUR-JZ

A 44 - A 45

PUR-JZ-HF

C 12 - C 13

PUR-JZ-HF-YCP

C 17 - C 18

PUR-ORANGE

A 46

PUR-Single Core
PUR-spiral Cables black

Q
Questionnaire

prex page 37

R
RD-H(St)H

B 34

RD-Y(St)Y

B 26

RD-Y(St)Yv / RD-Y(St)YY

B 27

RE-2Y(St)Yv

B 28

RE-2Y(St)Yv PiMF

B 29

Reg.-No.

A 6 - A 10, A 13,
A 25 - A 28,
A 31 - A 35,
A 38 - A 41,
A 80 - A 81,
C 5 - C 6, C 8 - C 9

Resistant to microbial attack

A 48 - A 49, A 51,
A 58 - A 59,
A 84 - A 89,
C 29 - C 30

RGB-KOAX-CY / RGB-KOAX-(St) Y

M 12

RG-Coaxial Cables halogen-free

M7

RG-Coaxial-Cable

M4-M6

Ribbon Cables

J8

ROBOFLEX 150, 151, 152, 153

H7-H8

ROBOFLEX 156-at

H9

ROBOFLEX 2001 / 2001-C

H6

ROBOFLEX recycle

H4-H5

ROBOFLEX robot Cable

H 10

ROBOFLEX-recycle

U 41 - U 57

Rubber Cable for use in water

I4-I7

Rubber Cable with strain bearing


element

F9

K 15
V5-V6

Rubber connecting Cables

U 59

X 122
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Glossary of Therms: Cables and Wires


Types

Page

Types

Page

Rubber-/Neoprene Control Cable

N 79

SiHF-C-Si

E 17 - E 18

Rubber-sheathed Cable
harmonized type

I 4 - I 5,
F5-F 7

SiHF-C-Si UL/CSA

N 77

Silicone Cables

Rubber-sheathed Cable
harmonized type

I 6 - I 7,
F5-F7

E 7 - E 9,
E 16 - E 19,
N 75 - N 77, N 119

Rubber-sheathed Cable (SO, SJO)

N 79

Silicone single cores

K 24 - K 25, N 119

Rupper insulated single core

K 16 - K 17, K 35

Simatic S7 front connecting Cable

U 60

Rupper insulated single core


halogen-free

K 16 - K 17

Single 600-CY-J/-O

N 121

Single 600-J/-O

N 120

Single 602-RC* -CY -J/O

N 123

Single 602-RC* -J/O

N 122

Single cores, halogen-free

K 15 - K 17,
K 22 - K 25,
K 30 - K 32, K 37,
N 117 - N 119,
N 124 - N 125

Single cores, HELUFLON-insulated

E 11 - E 12,
K 27 - K 28

S
SafetyBUS

R 158

SAT-Coaxial Cable

M 9 + M 11

Sensor-Aktuator-Cable

N 151 - N 152
T 42 - T 47

SENSORFLEX

T 42

Sensorex-H

T 46 - T 47

Servo-Cables

D9

Sheated Cables

O5-O9

Single cores, highly exible

K 14, T 5 - T 11

SHIPFLEX 109

W 20 - W 21

Single cores, PUR

K 15, T 9

SHIPFLEX 113

W 22

Single cores, PVC

SHIPFLEX 121

W 23

SHIPFLEX 330

W 18

K 4 - K 15,
K 19 - K 21,
N 108 - N 114,
N 116, T 5 - T 6, T 8

SHIPFLEX 340

W 19

Single cores, silicone-insulated

N 119, K 24 - K 25

SHIPFLEX 512

W 17

Single cores, temperature-resistant

K 19 - K 32,
N 117 - N 119

Ships Power Cables


MPRX 0,6/1kV

W 14

SJT

N 12 - N 13

Ships Power Cables


MPRXCX 0,6/1kV

W 15

SOLARFLEX-X PV1-F

T 18

SOLARFLEX-X PV1-F Twin

T 19

Ships Telephone Cables FMGCH


250 V (FMGCG*)

W7

Spiral Cable

V4-V5

Steel wire braiding

Ships Wiring Cables-SY single cores

W 12

A 34 - A 35,
A 40 - A 41

Ships Wiring Cables-SY stranded type

W 13

Short-circuit-proof installation

K 35 - K 36

Structured cabling
100 MHz CAT.5 Class D

R 54 - R 58
R 94 - R 100

SID

K 25

Structured cabling
250 MHz CAT.6 Class E

R 66 - R 67

SiF / SiFF

K 24

SiF/GL, SiD, SiD/GL

K 25

Structured cabling
600 MHz CAT.7 Class F

R 71 - R 76
R 81

SiHF

E7-E8

SUPER-PAAR-TRONIC 340-C-PUR

N 104

SiHF UL/CSA

N 75 - N 76

SUPER-PAAR-TRONIC-C-PUR

C 35

SiHF/GL-P

E 16

SUPERTRONIC 330 C-PUR

N 103

X
X 123
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Glossary of Therms: Cables and Wires


Types

Page

Types

Page

SUPERTRONIC-310-C-PVC

N 101

TOPFLEX 302 / 302-UL

T8

SUPERTRONIC-310-PVC

N 100

TOPFLEX 303 X07V-K-Y

T5

SUPERTRONIC-330 PUR

N 102

TOPFLEX 304 / 304-C

T 10

SUPERTRONIC-C-PUR

C 34

TOPFLEX 304 / 304-C

T 10

SUPERTRONIC-C-PVC

C 32

TOPFLEX 600 VFD

N 137

SUPERTRONIC-PUR

C 33

TOPFLEX 600-PVC, 600-C-PVC

D4+D6

SUPERTRONIC-PVC

C 31

TOPFLEX 611 PUR / C-PUR

D5+D7

SY-JB

A 40 - A 41

TOPFLEX 611-C-PUR

D7

SY-JZ

A 34 - A 35

TOPFLEX 650 VFD

N 138

S-YY Lg

P9

TOPFLEX MOTOR 103

N 150

TOPFLEX MOTOR 109

D 25 - D 26

Tachofeedback-Cable-C-PUR

D 11

TOPFLEX MOTOR EMV 1/1

N 147

Tachofeedback-Cable-C-PVC

D 10

TOPFLEX MOTOR EMV 3/3

N 148 - N 149

Tauchex-FL

I5

TOPFLEX-PUR

D 14 + D 16

Tauchex-R

I4

TOPFLEX-PVC

D 13 + D 15

Telephone indoor Cable

P6-P7

TOPGEBER 511 PVC

N 130

Telephone outdoor Cable

P4-P5

TOPGEBER 512 PUR

N 135 - N 136

Temperature up to +105C

E 4, K 19,
N 66, N 71,
N 108 - N 109,
N 113 - N 114

TOPSERV 510

N 136 - N 137

TOPSERV 600 VFD

N 139

TOPSERV 650 VFD

N 140

Temperature up to +400C

Chapter E

TOPSERV 108 PVC

N 127

TERMI-POINT-technic

B 16, B 25 - B 26

TOPSERV 109 PUR

N 131

THERMFLEX 145

T 39

TOPSERV 110 / 120 Feedback-Cable

D9

THERMFLEX 180 EWKF

E9

TOPSERV 112 PVC

N 128

THERMFLEX 180 EWKF-C

E 19

TOPSERV 113 PUR

N 132 - N 133

THHN/THWN

N 115

TOPSERV 119 PVC

N 129

N 145 - N 146

TOPSERV 121

N 135

TOPFLEX - EMV-2YSLCYK-J

D 17 - D 18

TOPSERV 121 PUR

N 134

TOPFLEX - EMV-3 PLUS 2YSLCY-J

D 21 - D 22

TOPSERV 130

D8

TOPFLEX - EMV-UV-2YSLCYK-J

D 19 + N 141

TRAGO / Lift-2S

F 11

TOPFLEX - EMV-UV-3 PLUS 2YSLCYK-J

D 23 + N 143

Trailing Cables

T 13 - T 14

TOPFLEX 1002

T7

TRAY-Cable

N 33 - N 34

TOPFLEX 240-PVC / 240-PUR

D 12

TRAYCONTROL 300

N 382 - N 39

TOPFLEX 240-PVC / 240-PUR

D 12

TRAYCONTROL 300 TP

N 42 - N 43

TOPFLEX 300

T6

TRAYCONTROL 300-C

N 40 - N 41

TOPFLEX 301 / 301-C

T9

TRAYCONTROL 300-C TP

N 44 - N 45

TOPFLEX 301 / 301-C

T9

TRAYCONTROL 500

N 27 - N 28

TOPFLEX

- EMV UV 2YSLC11Y-J

X 124
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Glossary of Therms: Cables and Wires


Types

Page

Types

Page

TRAYCONTROL 500-C

N 35 - N 36

UNIPUR-CP

A 58 - A 59

TRAYCONTROL 530

N 29

Use in water

I4-I6

TRAYCONTROL 600

N 30 - N 31

TRAYCONTROL 600-C

N 37

Vehicle Cable FLRY

K 44

TRAYCONTROL 670 HDP / 670-C HDP

N 32

Vehicle Cable FLY

K 41 - K 43

TRIAX Camera Cable

S 31

VERTEILERFLEX

T 45

TROMM-PUR

G5

VERTEILERFLEX two-approvals

TROMM-PUR-H

G4

N 151 - N 152,
T 43 - T 44

TRONIC (LiYY)

B4-B5

Video

S 29 - S 31

TRONIC 1-CY

B 18

TRONIC 2-CY

B 19

TRONIC-CY (LiY-CY)

B 9 - B 10

Truck Cables

T 52 - T 54

TUBEFLEX -(St)-CY

J 10

TUBEFLEX -Y

J9

Twin Cables

S 22

Twinaxial Cable

R 83

Two approvals control Cables

N 17 - N 18,
N 46 - N 48, N 51,
N 83, N 85 - N 88,
N 91 - N 93

U
UL (LiYCY)

N 69 - N 71

UL (LiYCY-TP)

N 72 - N 73

UL (LiYY)

N 65 - N 66

UL (LiYY-TP)

N 67 - N 68

UL/CSA JZ-600

N 10 - N 11

UL/CSA JZ-600-Y-CY

N 20 - N 21

UL/H05 VV-F

N 12 - N 13

UL-CSA-approved

prex page 28

UL-Style 1007, CSA TR 65

N 108

UL-Style 1011

N 115 - N 116

UL-Style 1015

N 110

UL-Style 1569, CSA TR 64

N 109

UL-Style 2464

N 65, N 67 - N 70,
N 72 - N 73

UL-Style 3135

N 119

UNIPUR

A 49 - A 50

W
Warning indication

A 23

Welding Cables

K 34

Wind Power Cable

T 27 - T 40

WK (N)A2XH

T 40

Y
Y-CY-JB

A 38 - A 39

Y-CY-JZ

A 32 - A 33

YELLOWFLEX

F4

YELLOWFLEX - Connecting Cables

U 60

Y-C-PUR-JZ

A 56 - A 57

YV-Equipment Wires/
YR-Bell Sheathed Cables

O4

X
X 125
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

From Part No.


10001 13360

Part No. index


Part No.

Page

Part No.

Page

Part No.

Page

10001 10047

A6

11700 11813

A 72

12680 12722

N 91

10048 10168

A7

11815 11846

N 10

12723 12746

A 66

10169

A6

11847 11876

N 11

12747 12804

A 67

10170

A7

11880 11911

N 10

12805 12846

N 48

10172 10173

A6

11912 11941

N 11

12850 12877

A 75

10174 10176

A7

11942 11952

A 77

12878 12907

A 76

10177

A6

11953 11964

A 78

10178 10182

A7

11965 11987

A 68

13001 13024

A 11

10183

A6

13025 13059

A 12

10184 10333

A7

12001 12056

A 34

13060 13083

A 29

10334 10339

A 23

12057 12111

A 35

13084 13118

A 30

10340 10387

A9

12112 12114

A 34

13119 13121

A 12

10533 10536

A7

12115 12119

A 35

13122 13123

A 11

10537 10547

A 10

12188

A 34

13124

A 12

10550 10615

A 16

12200 12310

A 40

13125 13126

A 11

10616 10746

A 17

12311

A 41

13127 13128

A 12

10747 10749

A 10

12312 12315

A 40

13129 13130

A 29

10750 10797

A8

12316 12317

A 41

13131 13132

A 30

10934 10980

A 24

12318 12324

A 40

13133 13136

A 13

12325 12326

A 41

13137

A 37

11001 11112

A 21

12327

A 35

13138

A 13

11121 11169

A 22

12328

A 41

13139 13140

A7

11201 11220

A 62

12345 12371

N 20

13141 13146

A 13

11221 11331

A 63

12372 12405

N 21

13147

A 37

11332 11334

A 62

12410 12436

N 20

13148 13166

A 13

11335 11341

A 63

12437 12470

N 21

13170 13199

A 31

11342 11347

A 71

12471 12517

N 46

13200 13215

N 58

11348 11350

A 72

12518 12543

N 47

13216 13343

N 59

11574 11629

A 37

12550 12620

N 51

13344 13367

A 64

11656 11689

A 71

12630 12671

N 86

13344 13360

N 54

X 126
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

From Part No.


13361 19968

Part No. index


Part No.

Page

Part No.

Page

Part No.

Page

13361 13489

N 55

15876 15894

C8

16491 16493

A 28

13368 13489

A 65

15925 15929

C9

16500 16530

B 10

13500 13515

A 73

15930 15952

C8

16531 16556

A 25

13500 13515

N 56

15961 15983

C9

16557 16585

A 26

13520 13597

A 74

15987 16000

B 18

13520 13597

N 57

17001 17022

B 12

13920 13930

A 11

16001 16049

B 10

17023 17044

B 13

13931 13949

A 12

16050 16118

A 26

17047 17056

B 12

13951 13962

A 29

16119

A 39

17172

A 32

13963 13985

A 30

16120

B 10

16121 16152

A 38

18001 18054

B4

14001 14027

A 80

16153 16156

A 39

18055 18113

B5

14028 14059

A 81

16157 16160

A 33

18114 18115

B4

14075 14076

A 80

16161

C 12

18116

B5

14077 14099

A 82

16163 16164

B 10

18117 18118

B4

14100 14102

A 80

16165

A 27

1812_ 1832_

A 49

16166

A 28

1833_ 1876_

A 50

15001 15036

C5

16167 16168

A 33

15037 15089

C6

16169 16175

A 32

19001 19033

B6

15090 15091

C5

16176 16183

A 33

19034 19078

B7

15092

C6

16196 16239

A 32

19101 19141

C 35

15093 15141

K 14

16240 16318

A 33

1915_ 1935_

A 58

151xx 159xx

K 14

16319

A 39

1936_ 1979_

A 59

15142 15150

C6

16320 16343

A 27

19798 19809

W 20

15152 15163

C9

16344 16452

A 28

19810 19821

W 21

15214 15216

C6

16453

A 32

19822 19835

W 22

15217 15232

N 60

16454 16468

A 33

19836 19845

W 23

15233 15283

N 61

16469 16474

A 39

19846 19863

W 18

15520 15589

C 12

16475 16489

B 10

19864 19926

W 17

15590 15656

C 13

16490

A 27

19927 19968

W 19

X
X 127

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

From Part No.


19969 22827

Part No. index


Part No.

Page

Part No.

Page

Part No.

Page

19969

W 21

21323 21329

B 21

22343 22362

E 10

19970 19995

B 12

21330 21410

W 20

22364 22367

A 60

21340 21373

B 21

22368 22374

D 21

20001 20028

B9

21385 21387

B 21

22375 22382

D 22

20029 20090

B 10

21400 21447

A 56

22385 22388

A 60

20091

B9

21451 21534

A 57

22389 22393

N 145

20092 20093

B 10

21535 21554

B 29

22394 22399

N 146

20099 20109

B 28

21559 21580

N 87

22400 22433

C 17

20115 20124

B 29

21581 21629

N 88

22434 22494

C 18

20125 20132

B 28

21630 21640

N 92

22501 22522

C 14

20133 20138

B 29

21641 21699

N 93

22523 22565

C 15

20139

B9

22566 22568

N 146

20140 20148

B 26

22001 22046

A 46

22571 22581

C 19

20149 20159

B 28

22050 22083

A 48

22582 22634

C 20

20160 20168

B 27

22084 22087

D 17

22637 22667

N 77

20169 20179

B 28

22088 22097

D 18

22673 22687

D 24

20180 20188

B 27

22100 22163

A 44

22689 22706

N 150

20189 20197

B 26

22164 22192

A 45

22707 22717

D 25

20200 20232

B 34

22193 22199

N 144

22718 22723

D 26

20233 20255

B 28

22200 22222

A 47

22724

D 25

2026_ 2037_

K 27

22223 22230

N 144

22800

D 15

22233

A 47

22801

D 12

21001 21010

B 11

22234 22239

D 19

22802

D 15

21011 21064

B 12

22240 22247

D 20

22803

D 15

21065 21076

B 14

22250 22273

A 46

22806

D 15

21077 21110

B 15

22290 22309

E 10

22818

D 11

21111 21127

B 17

22315 22319

A 60

22820

D 13

21129 21150

B 16

22320 22327

N 141

22823

D 11

21200 21251

A 54

22328 22333

N 142

22824 22825

D 10

21253 21322

A 55

22339 22342

A 60

22827

D 12

X 128
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

From Part No.


22828 25990

Part No. index


Part No.

Page

Part No.

Page

Part No.

Page

22828 22833

A 48

23147 23149

K 26

24333 24334

N 95

22834

D 14

23150

E 18

24335 24367

N 84

22835 22843

A 48

23151 23168

E 17

24370 24386

N 89

22845 22846

D 13

23169 23198

E 18

24387 24406

N 90

22847

D 16

232xx 248xx

K 24

24410 24426

N 94

22848 22849

D 14

23214 23237

N 75

24427 24444

N 95

22850 22854

D 16

23238 23290

N 76

24450 24467

N 96

22854 22855

D4

23291 23292

E 17

24468 24488

N 97

22856 22859

D6

23293 23294

E 18

24567 24582

N 105

22860 22869

D4

23314 23388

A 43

24614 24629

N 106

22870 22877

D5

23414 23443

A 52

2490_ 2499_

K 27

22878 22883

C 15

23444 23488

A 53

22884 22889

C 20

23914 23930

N 98

25001 25075

F9

22890 22892

D 12

23931 23949

N 99

25080 25101

F 11

22940 22943

E7

23953 23959

K 24

2511x 2545x

K 28

22944 22949

E8

25259 25268

F 10

22960 22967

D6

24002 24042

E4

25269 25281

N 124

22970 22977

D7

24043

C 23

25282 25294

N 125

22978

D5

24044 24046

E4

25439 25559

H6

22979

D5

24050 24085

C7

2551x 2561x

K 27

22980 22981

D5

24086 24118

C 10

25620 25690

A 84

22982 22985

D7

24119 24155

C 16

25691 25734

A 85

22989 23008

E7

24156 24190

C 21

25735 25760

A 86

24191 24208

C 22

25761 25825

C 26

23009 23059

E8

24209 24235

C 23

25826 25871

C 27

23062 23103

E 16

24236 24272

C 24

25872 25887

C 28

23104 23105

E7

24273 24285

E 11

25888 25900

N 124

23106 23110

K 26

24291 24292

E4

25901 25913

N 125

23127 23132

E7

24295 24330

N 82

25914

E 12

23133 23146

E8

24331 24332

N 90

25989 25990

E 12

X
X 129

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

From Part No.


26001 32429

Part No. index


Part No.

Page

Part No.

Page

Part No.

Page

26001 26032

G6

28034 28081

N 12

29800 29812

K 41

26035 26059

G5

28100 28104

J7

29813 29819

K9

26060 26119

K9

28145 28184

K 10

29825 29826

A 19

26125 26216

A 87

28185 28237

K 11

29840 29933

K9

26217 26272

A 88

28240 28271

N 49

29942 29968

K 19

26273 26306

A 89

28272 28301

N 50

29970 30104

K 21

26307 26346

C 29

28302

J7

26347 26385

C 30

28305 28336

N 49

3011_ 3026_

A 20

26386 26391

K6

28337 28366

N 50

3027_ 3047_

A 70

26392 26394

K7

28370 28396

N 52

26395 26402

K8

28397 28423

N 53

31001 31039

K 34

26403 26404

K9

28430 28456

N 52

31040 31096

G7

26405 26500

K4

28457 28483

N 53

3110_ 3125_

N 13

26505 26584

K5

28484 28571

K 44

26590 26637

K6

28761 28824

K 10

32001 32015

Q6

26640 26687

K7

28825 28877

K 11

32016 32088

Q7

26690 26753

K8

28900 28928

O4

32089 32103

Q6

26755 26936

K9

28930 28947

K 33

32104 32176

Q7

26937 26960

K 10

32177 32199

Q9

26980 27030

J4

29081 29128

K6

32200 32223

Q 12

29129 29192

K8

32224 32255

Q 13

27031 27089

A 91

29193 29368

K9

32256 32257

Q7

27090 27104

J6

29400 29417

A 18

32258

Q9

27105 27163

A 92

29418 29449

K9

32260 32283

Q 16

27164 27196

A 93

29450 29493

A 19

32284 32292

Q 17

27197 27234

A 94

29494 29499

K9

32293 32300

Q7

27235 27268

A 95

29500 29526

K 19

32301 32310

Q9

27269 27321

A 96

29590 29599

K9

32311 32399

Q 10

29600 29735

N 116

3233_ 3238_

A 69

29736 29744

A 18

32400 32429

Q 50

28001 28033

J5

X 130
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

From Part No.


32430 40151

Part No. index


Part No.

Page

Part No.

Page

Part No.

Page

32430 32437

Q 51

33240 33274

Q 15

37219 37258

F 13

32440 32467

Q 52

33275 33290

Q 10

37259 37286

F4

32468 32478

Q 53

37287 37332

I6

32480 32509

Q 54

34007 34040

P5

37333 37358

I7

32510 32517

Q 55

34050 34071

P 10

32520 32547

Q 56

34072 34080

Q 30

38001 38040

F 14

32548 32555

Q 57

34081 34089

Q 28

38501 38516

K 35

32556 32559

Q6

34090

F7

38517 38532

K 36

32560 32583

Q 58

34091 34099

Q 29

38533 38547

G9

32584 32591

Q 59

34100 34115

P4

32592 32596

Q 20

34116 34126

P 11

39001 39024

O5

32597 32599

Q 19

34130 34147

P4

39025 39039

N 80

32600 32622

Q 60

34148 34156

Q 28

39040 39048

G9

32623 32630

Q 61

34157 34165

Q 29

39050 39079

O5

32633 32634

Q 19

34166 34177

P 12

32640 32652

Q 21

34300 34311

P9

40001 40005

M4

32653 32685

Q 22

34339 34348

Q 62

40006 40010

M5

32686

Q 21

34349

F7

40011

M6

32687 32689

Q 22

34350 34356

B 33

40012

M5

3269_ 3283_

N 14

40013

M4

32840 32849

Q 18

40015 40021

M 11

32850 32893

Q8

40022

S 29

35001 36008

F5

37001 37028

F6

40023 40027

S 22

33001 33034

P7

37029 37068

F7

40028

S 29

33035 33053

P8

37069 37090

F8

40056

S 29

33100

P6

37091 37099

F7

40073

S 29

33101 33112

P6

37100 37153

I4

40085

M 11

33113 33156

Q 11

37154

F7

40135 40144

M8

33200 33211

B 30

37155 37175

I5

40145 40149

M 12

33212 33239

Q 14

37176 37218

F 12

40150 40151

M9

X
X 131

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

From Part No.


40159 52808

Part No. index


Part No.

Page

Part No.

Page

Part No.

Page

40159

M9

48510 48518

B 32

51716 51728

K 31

40160 40167

G8

48519 48528

B 31

51729 51740

K 32

40168 40169

M9

48529 48537

B 32

51741 51767

E 13

40170 40175

S 29

51768 51848

K 16

40176 40178

M 10

49501 49520

B 19

51849 51902

K 17

40179

M8

49521 49535

B 20

51970 51991

O7

40180 40189

S 22

49550 49582

C 31

51992 52017

O8

40190 40196

M7

49583 49615

C 33

40197

M5

49620 49652

C 32

52018 52057

E 20

40198 40203

M6

49653 49685

C 34

52058 52067

Q 31

40204 40333

K 41

49700 49763

A 51

52068 52097

Q 32

40334 40567

K 42

49764 49796

N 102

52098 52103

Q 33

40568 40801

K 43

49797 49829

N 103

52104 52134

Q 34

40802 40814

K 42

49830 49870

N 104

52194 52197

E 14

49885 49917

N 100

52198 52292

E 15

43050 43065

O6

49918

A 51

52300 52361

B8

43524 43564

B 25

49920 49952

N 101

52365 52382

B 23

52383

Q 32

44001 44058

J8

50060 50072

E 13

52384 52429

B 23

50209

K 29

52430 52431

B8

451xx 459xx

K 24

50475 50486

K 30

52432 52434

Q 32

45130 45145

J9

50488 50499

K 31

52435 52484

B 24

45150 45165

J 10

50635 50646

K 32

52490 52533

B 22

50650 50889

K 15

52534 52541

Q 39

50890 50997

K 29

52542 52612

Q 40

50998 51391

K 22

52614 52629

Q 32

52700 52714

Q 35

461xx 469xx

K 25

47001 47020

K 25

47021 47076

N 119

48500 48509

B 31

51419 51558

K 23

52715 52770

Q 36

51559 51702

K 29

52771 52780

Q 41

51703 51715

K 30

52781 52808

Q 42

X 132
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

From Part No.


52809 62875

Part No. index


Part No.

Page

Part No.

Page

Part No.

Page

52809 52867

K 17

53350 53375

O9

60000 60051

N 16

52872 52898

K 16

53376 53387

E5

601xx 618xx

N 110

52899

Q 40

53388 53389

E6

60216 60226

K 37

52900 52921

Q 37

53390

Q 44

60250 60287

N 15

52922 52944

Q 38

53391 53549

E6

60288 60298

K 37

52945 52968

K 16

53758 53761

Q 26

52969 52980

K 17

53762 53777

K 39

61816 61927

N 117

52990 52999

Q 44

61928 61980

N 42

61981 61998

N 43

61999

N 44

541_ 564_

K 18

53000 53003

Q 43

53004 53031

Q 44

59114 59135

K 39

53032 53047

Q 45

59138 59145

W7

620xx 624xx

N 108

53048 53069

Q 46

59150 59156

W9

62500

K 37

53070

Q 44

59212 59219

D8

62501

N 110

53071 53082

K 16

59262 59269

K 40

62502 62554

N 62

53083 53088

K 17

59270 59311

W4

62556 62600

N 63

53100 53135

Q 24

59312 59318

K 40

62601

N 110

53136 53142

Q 25

59336 59338

W5

62602 62605

N 63

53143 53151

Q 24

59360 59377

W6

62607 62624

N 139

53152 53179

Q 25

59380 59386

W8

62625 62684

N 38

53180 53191

Q 43

59390 59395

W 10

62685 62700

N 39

53200 53235

Q 26

59396 59397

W 11

62701

N 110

53236 53238

Q 27

59450 59457

W 12

62702 62709

N 39

53239 53242

Q 26

59460 59471

W 13

62710 62765

N 40

53243 53245

Q 27

59472 59653

N 118

62766 62793

N 41

53246 53247

Q 26

59654 59706

W 14

62794 62800

N 42

53248 53292

Q 24

59707 59758

W 15

62801

N 110

53293 53299

Q 25

59760 59810

N 44

62802 62812

N 28

53300 53308

O9

59811 59836

N 45

62813 62868

N 35

53309 53336

Q 25

59837 59854

N 140

62869 62875

N 36

X
X 133

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

From Part No.


62876 73726

Part No. index


Part No.

Page

Part No.

Page

Part No.

Page

62876 62884

N 138

65243 65285

N 68

71789

H8

62901

N 110

65286 65313

K 20

71820

H8

62902 62942

N 30

65314 65349

N 72

71901

T 14

62943 62969

N 31

65350 65385

N 73

71990 71997

D9

62970 62988

N 30

62989 62996

N 31

660xx 668xx

N 109

72042 72043

D9

62997

N 37

66820 66837

N 32

72082

T5

66840 66883

N 29

72106

D9

72184 72185

T5

63010 63048

N 79

63049 63078

N 37

69601 69624

N 122

72214

H8

63079 63133

N 27

69631 69654

N 123

72872

T6

63136

N 62

69661 69714

N 25

72944 72950

T8

63137

N 137

69715 69737

N 26

72951

T 45

63138

N 138

69750 69803

N 33

72961

T 45

63139 63155

N 137

69804 69826

N 34

72973

T 42

63156 63163

N 138

63164

N 27

70116

H8

73368

T 42

63165 63199

N 28

70377

T 14

73466 73485

T 42

6320x 6332x

N 115

70402

T 14

73519

T 14

63331 63401

N 115

70518 70519

T6

73548

T 42

635xx 638xx

N 108

70536

T6

73571

N 151

63815 63862

N 111

70561

H8

73571

T 43

63863 64070

N 112

70736

T 13

73574

T 45

70931

T 14

73575

T 47

73579 73580

N 134

64075 64122

N 113

64123 64330

N 114

71254

T 45

73587

N 152

71369

T 14

73587

T 44

65044 65087

N 70

71491 71493

D9

73657

T 42

65114 65133

N 71

71544

T 10

73714

T6

65214 65242

N 67

71705 71711

D9

73726

T 14

X 134
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

From Part No.


73728 77469

Part No. index


Part No.

Page

Part No.

Page

Part No.

Page

73728

T 42

75450 75458

T8

76348

T 43

73774

N 134

75460 75479

T5

76349

N 151

73859

T5

75497 75499

T 11

76349

T 43

73870

T 42

75507 75515

T 54

76350

N 152

73884 73885

T6

75528 75541

T 53

76350

T 44

73913

T 14

75614

N 152

76351

N 151

73924

T8

75614

T 44

76351

T 43

73993

T 45

75642

N 151

76352

N 152

75642

T 43

76352

T 44

74034

T 45

75801

T 47

76353

N 152

74094 74096

N 134

75932

T 53

76353

T 44

74221

T5

75940

H8

76354

N 152

74293

T 14

75943 75951

N 131

76354

T 44

74297

T 14

75956 75959

N 133

76355

N 152

74506 74514

N 133

75978 75980

N 134

76355

T 44

74551

N 152

75992

T 49

76356

N 152

74551

T 44

76356

T 44

74658

H8

76061 76099

T 42

76639 76640

T 45

74670

T 14

76103

N 134

76705

T 47

74729

T 45

76105 76123

T 45

76706

T 54

74749

T 11

76157 76175

H8

74992 75019

E9

76283 76294

T 46

77144 77175

G4

76295 76298

T 47

77261 77270

H8

75167

H8

76299 76310

T 46

77352

N 152

75251 75253

H8

76311 76314

T 47

77352

T 44

75254 75319

T 52

76345

N 151

77376

N 133

75375 75410

T9

76345

T 43

77424

H8

75415 75418

H8

76347

N 151

77427 77429

T 47

75431 75445

T6

76347

T 43

77468

T 47

75449

T5

76348

N 151

77469

H8

X
X 135

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

From Part No.


77532 80450

Part No. index


Part No.

Page

Part No.

Page

Part No.

Page

77532

T 14

78499

H9

80072 80073

R 83

77538

T 14

78614 78626

N 149

80074 80076

R 85

77548

T 13

78828

N 136

80084 80116

R 25

77642

T 45

78948 78952

N 133

80120 80130

R 25

77741 77753

N 136

78955 78958

N 134

80131 80138

R 17

78963

N 136

80139 80146

R 18

78983

T 54

80148 80155

R 17

80156 80162

R 18

78079 78081

N 136

78106 78117

T6

78122 78125

T 14

79513

N 136

80164 80171

R 17

78240 78241

T 42

79613

N 136

80172

R 18

78265 78268

T 46

79623 79638

T6

80175 80178

R 18

78269 78275

T 47

79639 79666

T 10

80180 80187

R 20

78284

N 151

79685

T 10

80188 80195

R 21

78284

T 43

79804 79830

E 19

80196 80204

R 20

78286

N 151

79850

N 151

80207 80211

R 21

78286

T 43

79850

T 43

80212 80218

R 20

78287

N 151

79907

N 151

80219

R 21

78287

T 43

79907

T 43

80220

R 20

78288

N 151

79921

T 45

80223 80227

R 21

78288

T 43

80264 80265

R 13

78289

N 152

80000 80028

R 24

80267

R 111

78289

T 44

80031

R 25

80270 80281

R 13

78290

N 152

80032 80041

R 24

80294

R 73

78290

T 44

80043

R 58

80316

R6

78291

N 152

80044

R 85

80363

R 34

78291

T 44

80045

R9

80382

R 34

78359

T 47

80046 80051

R 24

80384

R 107

78372

N 136

80053

R 54

80388

R 46

78377 78388

N 147

80055

R 57

80418 80435

R8

78479

N 147

80068 80071

R 84

80436 80450

R 18

X 136
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

From Part No.


80473 82431

Part No. index


Part No.

Page

Part No.

Page

Part No.

Page

80473 80475

R 24

80810

R 71

81278

R 59

80495 80518

R 32

80813 80821

R7

81286 81287

R 132

80532

R 46

80824 80825

R 147

81382

R 21

80534

R 34

80826

R 161

81446

R 72

80576 80578

R 26

80846

R 14

81447

R 163

80627

R 26

80851

R 13

81448

R 107

80629 80630

R 46

80868 80894

R9

81478

R 23

80631

R9

80895

R 26

81495

R 14

80672

R 26

80896 80908

R9

81501

R 120

80681

R 13

80912 80914

R 24

81557

R 143

80688

R7

80915 80959

R 26

81609 81610

R 62

80691

R 26

81611

R 46

80699

R6

81003

R 111

81663

R 160

80725

R 13

81036 81038

R 34

81699

R 79

80732

R 26

81077

R 161

81712

R 152

80735

R 26

81081

R 160

81713

R 114

80743

R7

81085

R 163

81882

R 46

80753 80754

R7

81108 81121

R 21

81900

R6

80759

R 25

81123

R 63

81903 81904

R 119

80764

R 24

81133 81136

R 21

81905

R 120

80769

R7

81137 81149

R 25

81906

R 121

80771

R 25

81155

R 99

81907 81908

R 155

80774

R 24

81186

R 108

81909 81910

R 156

80777

R 24

81202

R 142

81911 81912

R 140

80778

R 142

81203

R 144

80782 80791

R6

81209

R 31

82032 82033

R 46

80792

R 108

81238

R 40

82190

R 30

80793

R9

81246

R9

82390 82407

R 33

80795 80806

R7

81254

R 64

82408 82412

R6

80809

R 26

81255 81260

R 31

82431

R 13

X
X 137

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

From Part No.


82434 87919

Part No. index


Part No.

Page

Part No.

Page

Part No.

Page

82434

R 148

83233 83253

N 66

85686 85795

V 10

82488

N 18

83254 83280

N 69

85900 86001

V 11

82501

R 66

83286 83344

N 70

82502

R 67

83350 83370

N 71

86004 86073

V 12

82509

R 133

83371 83498

N 65

86303 86411

V5

82561

R 31

83565

N7

86415 86491

V6

82648

R 21

83624 83644

N 66

86740 86741

U 59

82696

R 144

83650 83708

N9

86762

U 62

82780 82783

N 18

83709 83773

N 19

86764 86765

U 58

82786

R 31

83774 83809

N 72

86774 86782

U 61

82792 82803

R 11

83810 83845

N 73

86867 86870

U 58

82804 82818

R 10

83904 83932

N 67

86960 86961

U 59

82822

R 148

83933 83975

N 68

86989

U 61

82824

R 109

83976 83997

N 69

82835 82836

R 116

87074

U 58

82838

R 96

84178

U 62

87084

U 59

82839

R 97

84400 84476

U 58

87127 87143

U 58

82913

R 112

84481 84499

U 59

87145

U 59

82914 82940

N 18

84500 84612

V4

87164, 87196

U 62

82941 82942

N 17

84653 84655

U 59

87277

U 58

82943 82944

N 18

84656 84673

U 61

87328

U8

82945 83000

N 17

84674 84691

U 62

87406

U 59

84700 84812

V4

87410

U 58

83001 83024

N8

84867 84875

U 63

87416, 87445

U 62

83031 83044

N7

84903 84915

V5

87503

U 58

83045 83050

N 65

84919 84979

V6

87549

U 62

83051 83054

N7

87604

U 59

83055 83059

N 65

85221 85355

V7

87725, 87748

U 58

83060 83104

N7

85357 85508

V8

87845, 87919

U 62

83130 83227

N 65

85550 85675

V9

X 138
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

From Part No.


89293 660870

Part No. index


Part No.

Page

Part No.

Page

Part No.

Page

89293

U8

400109 400115

S 25

660666 660667

U5

89800 89802

U6

400116 400122

S 26

660668

U6

89900 89941

N 83

400143 400150

S 28

660669 660675

U7

89950 89992

N 85

400151

S 17

660676 660679

U8

660680 660688

U 13

660689 660730

U 15

660731

U 18

400000 400002

S3

600154 600157

V 11

400003 400010

S4

400011

S5

650086 650092

U 63

660732 660737

U 15

400012 400020

S6

650122

U8

660738

U 18

400021

S8

650200 650213

U 63

660739 660751

U 15

400022 400024

S9

650950 650965

U 60

660752 660756

U 16

400025 400029

S 10

660757 660761

U 17

400030

S 11

660014 660038

U8

660762 660764

U 18

400031

S 12

660053 660089

U6

660766 660771

U 19

400032 400033

S 13

660090 660160

U 14

660772 660773

U 20

400034

S 14

660207 660222

U7

660774

U 21

400035

S 15

660224 660259

U5

660776 660785

U 24

400036 400037

S 18

660260 660314

U 17

660786 660794

U 25

400038 400039

S 19

660334

U 18

660795 660814

U 26

400040

S 20

660335

U 20

660815 660821

U 27

400041

S 21

660350

U 18

660822 660823

U 30

400042 400043

S7

660351

U 22

660824 660833

U 31

400056 400059

S 24

660445

U 21

660834 660837

U 32

400060

S 23

660482

U 18

660838 660841

U 33

400061 400062

S 27

660500

U 19

660842 660845

U 34

400068 400072

S 30

660510

U 25

660846 660849

U 35

400073 400078

S 31

660627

U 15

660850

U 23

400080

S 20

660628

U 17

660851 660852

U 28

400081

S 16

660630

U 26

660853 660854

U 29

400089 400094

S 23

660648

U 19

660855 660870

U9

X
X 139

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

From Part No.


660871 702808

Part No. index


Part No.

Page

Part No.

Page

Part No.

Page

660871 660886

U 10

671341

U 44

700035

T 54

660887 660889

U 11

671351

U 49

700114

T8

660890 660892

U 12

671356

U 49

700142

T 52

660893

U 36

671426 671433

U 47

700159 700160

T7

660894

U 37

671434 671441

U 42

700199

N 133

660897

U 30

671473 671478

U 41

700231 700235

T8

671483 671489

U 45

700437

N 131

670656 670659

U 48

671493 671499

U 44

700540

N 136

670660 670667

U 51

671533 671537

U 45

700560

N 136

670668 670675

U 48

671543 671557

U 41

700561 700565

N 134

670676 670683

U 51

671720

U 42

700566 700572

T 50

670684 670696

U 48

671759

U 54

700573 700754

T 49

670710 670717

U 47

671833 671889

U 53

700575

T 52

670718 670725

U 42

671893 671949

U 52

700576 700583

T 52

670726 670733

U 47

671953 672019

U 54

700585 700596

T 53

670734 670741

U 42

700653 700657

N 136

670742 670749

U 41

672023 672039

U 55

700768 700771

T 11

670750 670753

U 44

672303 672339

U 46

700897

N 131

670757 670769

U 45

672343 672369

U 43

670771 670777

U 44

672373 672379

U 46

701219

E 19

670781 670793

U 45

672393 672409

U 43

701308

N 147

670802 670817

U 44

672413 672414

U 43

701351 701359

T8

670822 670825

U 49

672416 672417

U 43

701377 701388

T7

670826 670833

U 50

672419

U 43

701889 701900

H4

670834 670837

U 49

672443 672444

U 46

701901 701913

H5

670838 670845

U 50

672446 672447

U 46

670849 670865

U 49

672449

U 46

702050

N 136

670866 670867

U 44

702803 702805

H4

702806 702808

H5

671332 671335

U 50

700016 700018

T 52

700032

T 52

X 140
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

From Part No.


703843 802145

Part No. index


Part No.

Page

Part No.

Page

Part No.

Page

703843 703902

H5

707417

N 130

800980

R 41

707418

N 136

707738 707740

N 136

801147

R 74

707746 707747

N 133

801182

R 32

801183

R 23

801190

R 15

801191

R 123

704225 704234

T 18

705221

N 136

705413

N 136

705461

N 130

705462

H6

800044

R 112

801192

R 124

705738 705739

T 18

800067

R 100

801193

R 125

705769

T 19

800068

R 94

801194

R 101

705775 705778

T 18

800088

R 98

801195

R 102

705891 705894

T 18

800109

R 115

801196

R 42

800126

R 39

801197

R 89

770001 770005

T 50

706003

N 134

800497

R 157

801198

R 45

706288 706289

T 18

800571

R 137

801200 801202

R 47

706333

N 136

800579

R 40

801217 801221

R 15

706839 706840

T 18

800647

R 80

801352

R 38

800648

R 110

801572 801573

R 135

707077

N 130

800649

R 115

801650

R 102

707221 707225

N 128

800650

R 118

801651

R 103

707228 707232

N 133

800651 800652

R 158

801659

R 121

707234 707236

T 19

800653

R 101

801727

R 34

707250 707258

N 127

800654 800655

R 105

801733

R 44

707280 707288

N 128

800681 800682

R 154

801846 801847

R 149

707290 707296

N 129

800683 800684

R 153

801954 801955

R 150

707389 707390

N 130

800685

R 137

801982

R 134

707392

N 130

800708 800710

R 30

707394

N 130

800715

R 118

802001 802004

R 45

707397 707398

N 130

800753

R 32

802131 802142

R 19

707400 707410

N 136

800754 800762

R 19

802143 802145

R 11

X
X 141

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

From Part No.


802167 804045

Part No. index


Part No.

Page

Part No.

Page

Part No.

Page

802167

R 75

802473

R 129

804043

R 70

802168

R 76

802792

R 35

804045

R 60

802169

R 81

802800

R 162

802170

R 82

802917 802918

R 29

802171

R 55

802172

R 56

803037 803038

R 22

802173

R 61

803295

R 104

802174

R 65

803344

R 136

802177

R 109

803346 803349

R 36

802178 802179

R 113

803354

R 122

802180 802181

R 117

803364

R 37

802182

R 141

803378

R 68

802183

R 151

803379

R 69

802184

R 91

803380

R 77

802185

R 104

803381

R 78

802186

R 106

803382

R 90

802187 802188

R 159

803383 803384

R 139

802247 802249

R 12

803387

R 93

802260

R 43

803658 803661

R 28

802261 802276

R 14

803664

R 27

802277 802278

R 12

803668

R 28

802281

R 14

803672

N 130

802293

R 95

803672

R 128

802339

R 141

803693

R 92

802469

R 130

803722

R 138

802470

R 131

803917 803920

R 16

802471

N 130

803923 803924

R 22

802471

R 126

803925 803928

R 29

802472

R 127

803930 803932

R 28

802473

N 136

803934 803935

R 35

X 142
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Notes

X 143
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Notes

X 144
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Notes

X 145
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Notes

X 146
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Fax response to
(410)358-3142 (800)872-9329

co

S
ple imp
te ly
an
df

Please send me the following documents:


Cables & Wires catalogue

Robotics brochure

Cable Accessories catalogue

Wind power brochure

Data, Network & Bus Technology catalogue

Photovoltaic brochure

Media Technology catalogue

Flyer - The system supplier

Sender (stamp)
We would like:
General documentation
Visit from a sales representative
A quotation for:

Contacts

Contact
HELUKABEL GmbH . Headquarters
Dieselstrae 8-12 . 71282 Hemmingen
Ph. +49 7150 9209-0 . Fax +49 7150 81786

HELUKABEL AB
Spjutvgen 1 . S - 175 61 Jrflla
Ph. +46 8 7617805 . Fax +46 8 6210059
info@helukabel.se

HELUKABEL AG

Grabckerstrasse 60 . CH - 8957 Spreitenbach HELUKABEL CZ s.r.o.


Arel dolu MAX . CZ - 27306 Libun/Kladno
Ph. +41 56 4181515 . Fax +41 56 4181516
Ph. +42 0312 672620 . Fax +42 0312 672621
info@helukabel.ch
info@helukabel.cz
HELUKABEL ITALIA S.R.L.

Via delle Rovedine, 23 . I - 23899 Robbiate (LC) OOO HELUKABEL Russia


Ph. +39 039 9515450 . Fax +39 039 9281579 St. Petersburg
Ph. +7 981 7691474
info@helukabel.it
info@helukabel.ru
HELUKABEL Polska Sp.z o.o.
HELUKABEL Kablo San.veTic.Ltd.Sti
Krze Duze 2 . PL - 96325 Radziejowice
Siyavuspasa Cad. Cevizlik Sok. Birlik Ap. 19/1
.
Ph. +48 46 8580100 Fax + 48 46 8580117
TR - 34182 Bahcelievler/Istanbul
info@helukabel.pl
Ph. +90 212 5024195 . Fax +90 212 5024198
HELUKABEL B.V.
info@helukabel.com.tr
De Kempen 4 . NL - 6021 PZ Budel/Eindhoven

Ph. +31 495 499049 . Fax +31 495 499048 in- HELUKABEL USA, Inc..
1355
Bowes
Rd, Unit C USA - Elgin, IL 60123
fo@helukabel.nl
Ph. +1 847 9305118 . Fax + 1 847 6228766
info@helukabel.com
HELUKABEL France SARL
3, rue DMC-B.P. 30 Z.A. du Pont dAspach
HELUKABEL Intl Trading
F - 68520 Burnhaupt le haut
(Shanghai) Co., Ltd.
Ph. +33 389 627562 . Fax +33 389 627700
1st Floor, Bldg No. 4, 668 HengAn Rd., Puinfo@helukabel.fr
dong New Dist. Shanghai
PRC - 200137 Shanghai
HELUKABEL BELGIUM BVBA
Ph. +86 21 58693999 . Fax +86 21 58693666
Z.1 Researchpark 310 . B - 1731 ZELLIK
.
info@helukabel.com.cn
Ph. +32 24 810020 Fax +32 24 810022
info@helukabel.be

HELUKABEL Singapore Pte. Ltd.


No. 3, New Industrial Road #01-01 Kimly Building SGP - Singapur 536197
Ph. +65 64 880170 . Fax +65 62 851513
info@helukabel.sg
HELUKABEL KOREA Co., Ltd.
521-17 Daejeo 2 Dong Gang-seo Gu
ROK - Busan Korea
Ph. +82 51 9728646 . Fax +82 51 9728649
info@helukabel.co.kr
HELUKABEL (Thailand) Co. Ltd
73/4 Moo.1 Bangkruay-Sainoi Rd.
Banglane, Bangyai . T - 11140 Nonthaburi
Ph. +66 2927 35703 . Fax +66 2927 35745
info@helukabel.co.th
HELUKABEL INDIA PVT. LTD.
F-305 Kailash Complex, Hiranandani Gardens
Link Road, Vikhroli West
IND - Mumbai 400 079
Ph. +91 22 25185841. Fax +91 22 25185839
info@helukabel.in

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

ax

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

Photo: Helukabel Research, development and production Windsbach/Nuremberg

Note
Technical alternations
HELUKABEL GmbH Hemmingen
Subject to technical alternations. All illustrations, symbolic, inscriptions, markings, numbering etc., on the outer jacket are therefore without guarantee. Differences in colour between
photos and deliverot goods cannot be avoided. All rights for reprinting or reproduction of text and illustrations, in whole or in part, reserved. The transfer or copyrights principally
requires the written permission of HELUKABEL GmbH. Our general terms and conditions of sale and payment are valid, visible at www.helukabel.de.
The length marking
The length marking, which is not calibratable, represents a tool, e.g. for a simple material allowance determination or for the specications of the residual length that remains on the
drum. The deviation of the wire length represented by the length marking can be up to 1%. Incomplete length markings, length markings missing on sections or deviations of the wire
length represented by the length marking do not establish a statutory duty. Only calibrated measuring devices must be used to determine the wire length.
Safety instructions
The cables and wires described in the catalog are manufactured in accordance with domestic and international standards as well as in-house standards. Adherence to the then valid
safety guidelines, standards and legal regulations is provided for application safety. Product specic dangers can be excluded assumed a proper and professional installation and usage
is guaranteed. For each product, this catalog describes general information for usage. Independent of the above, the specications of the appropriate DIN VDE specications are valid.
However, the installation and processing can only be performed by professional electricians.

Our general terms and conditions of sale and payment for non-north american customers are valid, visible at www.helukabel.de

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

The Logistic Centre Hemmingen

HELUKABEL Products
are available from

MARYLAND METRICS
P.O. Box 261
Owings Mills, MD 21117 USA
ph: (410)358-3130 (800)638-1830
fx: (410)358-3142 (800)872-9329
email: sales@mdmetric.com
web: http://mdmetric.com

SDZeCOM/1211/7EN/Koe

RFQ form: http://mdmetric.com/rfq.htm

HELUKABEL GmbH
Headquarters
Diesel-strae 8-12
71282 Hemmingen Germany
Phone +49 7150 9209-0
Fax
+49 7150 81786

Other branches:
France Italy Switzerland Netherlands
Belgium Sweden Czech Republic Poland
Turkey South Africa China India
Malaysia Singapore South Korea Thailand
Russia USA

Also click here to access the Helukabel Cable Accessories catalog


copyright 2012 maryland metrics/helukabel gmbh

HELUKABEL Products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA web: http://mdmetric.com
ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
How to order: Please preface each HELUKABEL part number with 'R955K-' Example (using the part number): R955K-14078

You might also like