General Notes (Architectural):

FLOOR FINISHES:
FF1- Polished Concrete Finish
FF2- Laminated Wood Flooring Finish
FF3- 300X300 Vitrified Floor Tiles (Maskara White)
FF4- Plain Concrete Finish
WALL FINISHES:
Dining Area
Kitchen
Toilet
Mezzanine Floor

- White Bricks
- White Bricks, Brown Paint Finish
- 300x300 Vitrified Floor Tiles
- 300x300 Vitrified Floor Tiles

CEILING FINISHES:
Dining Area
Kitchen

- Polished Concrete in Black Paint Finish


- 600x600mm Mineral Fiber Board in Square Edge
Connection
Toilet
- Marine Plywood in Gray Flat Paint Finish
Mezzanine Floor
- Marine Plywood in Gray Flat Paint Finish

DOORS AND WINDOWS


D-1: DOUBLE ACTION DOUBLE DOOR (6mm TEMPERED GLASS PANEL)
D-2: DOUBLE ACTION DOOR (6mm TEMPERED GLASS PANEL)
D-3: SOLID WOOD DOOR
D-4: DOUBLE ACTION SINGLE DOOR
D-5: LOUVERED DOOR

W-1: 6mm TEMPERED GLASS FIXED WINDOW


W-2: 6mm TEMPERED GLASS FIXED WINDOW
W-3: AWNING WINDOW
W-4: 12mm TEMPERED GLASS FIXED WINDOW
W-5: 6mm TEMPERED GLASS FIXED WINDOW
W-6: 12mm TEMPERED GLASS FIXED WINDOW
W-7: 6mm TEMPERED GLASS FIXED WINDOW

KITCHEN
1 - 2000X700mm PREPARATION TABLE
1 4 LAYER UTILITY RACK
1 PREPARATION SINK
1 2760X700mm PREPARATION TABLE WITH DISH RACK
2 GRILLER
1 HP BURNER (FOUR OPEN TOP)
1 GAS RANGE
1 40 CU.FT CHILLER
7 PREFABRICATED JEEPNEY LOOK FOOD TRAY
3 DISHWASHING LAVATORY
1 60 CU.FT CHILLER
3 STORAGE FOR CANS
2 VEGATABLE STORAGE WITH MIST SPRINKLER
2 RICE COOKER
3 RANGE HOOD
1 2.5HP SPLIT TYPE AIR CONDITIONER
DINING AREA
20 1000x840mm STAINLESS STEEL DINING TABLE
40 UPHOLSTERED DINING CHAIRS
4 PREFABRICATED JEEPNEY DINING SET
9 WASHING LAVATORY
3 LAVATORY TABLES
3 HAND BLOWER
9 HAND SANITIZER STEEL CABINET
1 RECEPTION TABLE
2 UPHOLSTERED SOFA

COMFORT ROOM
4 LAVATORY
4 LAVATORY TABLE
4 WATER CLOSET
2 URINAL
4 BAR HANDLE (FOR PWD)
4 FRAMELESS MIRROR (1.2mx1m)
4 HAND BIDET SPRAY
4 TISSUE HOLDER
4 HAND BLOWER
4 HAND SANITIZER STEEL CABINET
4 EXHAUST HOOD

MANAGERS OFFICE
OFFICE PROPER
1 MANAGERIAL TABLE
3 CLERICAL TABLES
1 MANAGERIAL CHAIR
3 COMPUTER CHAIR
PRINTER

4 COMPUTER SETS (MONITOR, CPU, SPEAKER, KEYBOARD, MOUSE, UTS,


4 DESK LAMP
4 TELEPHONE SET
2 1HP AIRCONDITION

TOILET AND BATH


1 LAVATORY
1 LAVATORY TABLE
1 WATER CLOSET
1 URINAL

1 BAR HANDLE (FOR PWD)


1 SHOWER
1 HAND BIDET SPRAY
1 TOWEL HOLDER
1 TISSUE HOLDER
1 EMERGENCY KIT
1 HAND BLOWER
1 HAND SANITIZER STEEL CABINET

GENERAL EQUIPMENT

6 2.5HP CASSETE TYPE AIR CONDITIONER


26 - SMOKE VACUUM FUNNEL
1 AIR CURTAIN (Door)

GENERAL PLUMBING NOTES:


1. ALL PLUMBING WORKS INDICATED HEREIN SHALL MEET THE PROVISION OF THE
PLUMBING CODE OF THE PHILIPPINES, THE NATIONAL PLUMBING CODE, and
LOCAL CITY ORDINANCE RULES & REGULATIONS.
2. PLUMBING CONTRACTOR TO COORDINATE WITH OTHER RELATED DRAWINGS
AND SPECIFICATIONS, AND NOTIFY THE CONSULTING ENGINEER OF ANY
DISCREPANCY FOUND THEREIN.
3. ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS. ANY RELOCATION
REQUIRED FOR PROPER EXECUTION OF OTHER TRADE SHALL BE WITH PRIOR
APPROVAL OF THE ARCHITECT OR ENGINEER.
4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL SITE
CONDITION, DEPTH AND INVERT ELEVATION OF ALL EXISTING PIPES AND
STRUCTURES AS VERIFIED BY THE CONTRACTOR.
5. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 1% UNLESS
OTHERWISE SPECIFIED.
6. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS.
7. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE, TAPPING POINT
AND WATER LINE SERVICE CONNECTING POINT UNLESS OTHERWISE SPECIFIED.
8. ALL FIXTURES SHALL BE INDIVIDUALLY VENTED.
9. ALL PIPE SIZE AND DIMENSION ARE IN MILLIMETERS, UNLESS OTHERWISE

GENERAL ELECTRICAL NOTES:


1. ALL WORKS HEREIN SHALL COMPLY WITH THE APPLICABLE PROVISIONS OF THE
PHILIPPINE ELECTRICAL CODE, RULES AND REGULATIONS OF THE UTILITY COMPANY AND
THE IMPLEMENTING POLICIES OF THE LOCAL GOVERNMENT AUTHORITIES.
2. UTILIZATION VOLTAGE SHALL BE 220V, 1, 60HZ
3. WORKMANSHIP SHALL BE OF HIGHEST STANDARDS AND QUALITY. ALL MATERIALS TO BE
USED FOR INSTALLATION SHALL BE NEW AND SUITABLE FOR THE TYPE OF PURPOSE OF
APPLICATION.
4. VOLTAGE DROP FOR FEEDER CONDUCTORS SHALL NOT EXCEED 3% AT THE FARTHEST
OUTLET OF POWER/LOADS, AND MINIMUM TOTAL VOLTAGE DROP ON BOTH FEEDERS
AND BRANCH CIRCUITS TO THE FURTHEST OUTLET SHALL NOT EXCEED 5%
5. GROUNDING SYSTEM SHALL HAVE A RESISTANCE VALUE NOT EXCEEDING 5 OHMS. ALL
EQUIPMENT ENCLOSURES SHALL BE EFFECTIVELY GROUNDED.
6. PROVIDE PULLBOX OR JUNCTION BOX AS MAY BE REQUIRED BY ACTUAL FIELD
CONDITIONS AND SHOULD BE INSTALLED IN CONVENIENT AND INCONSPICUOUS
LOCATION. BOXES SHALL BE FILL WITH 50% OF WIRE SPACE.
7. EXPOSED CONDUIT WORKS SHALL RUN IN PARALLEL OR PERPENDICULAR TO THE
BUILDING STRUCTURES AND FINISHES.
8. GENERAL MOUNTING HEIGHT OF DEVICE AND EQUIPMENT ARE AS FOLLOWS:
WALL SWITCHES 1300 AFF ON CENTER
WALL RECEPTACLE, TEL. OUTLETS 300MM ON CENTER
PANELBOARDS 1800MM AFF @ TOP
DISCONNECTS, ENCLOSURES NOT EXCEED 1500MM AFF
REFER TO DRAWINGS FOR OTHER CASES OF INSTALLATIONS.
9. COORDINATE EXACT LOCATIONS FOR INSTALLATIONS WITH OTHER TRADES
10. THE CONTRACTOR SHALL BE RESPONSIBLE WITH THE SIGNED/SEALED OF
CERTIFICATE OF ELECTRICAL COMPLETION AND SUBMIT AS-BUILT PLANS DULY
SIGNED WITH SEAL OF SUPERVISING ENGINEER, AS-BUILT PLANS SHALL BE IN AUTOCAD
DRAWING .

11. MATERIAL SPECIFICATION


CONDUIT : IMC/RSC - SERVICE ENTRANCE AND EXPOSED CONDUIT WORK
IMC/RSC/EMT - POWER AND LIGHTING SYSTEM (EXPOSED)
PVC SCH. 40 - ALL AUXILIARY SYSTEM EMBEDDED CONDUIT
WIRES : PHELPS DODGE OR AMERICAN WIRE & CABLE BRAND
SWITCHES : NATIONAL/TOSHIBA BRAND
RECEPTACLES: LOCAL MANUFACTURERS
C.BREAKER : SQUARE-D OR GE BRAND
12. ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT SUPERVISION OF A
DULY LICENSED ELECTRICAL ENGINEER/ MASTER ELECTRICIAN.
13. ALL ELECTRICAL PIPES LAYOUT OUTSIDE BUILDING SHOULD HAVE A MINIMUM DEPTH
OF 40MM OR IF NOT MEET PROVIDE A CONCRETE ENCASEMENT ENVELOPE OF 50MM
14. ALL ELECTRICAL SERVICE ENTRANCE UNDERGROUND PIPES LAYOUT SHOULD HAVE A
MINIMUM DEPTH OF 600MM WITH A CONCRETE ENCASEMENT.
15. ALL FINAL LOCATION OF RECEPTACLES, LIGHTING OUTLETS, AND SWITCHES SHALL BE
APPROVED BY OWNER/ ARCHITECT/ CONSULTANT PRIOR TO INSTALLATION.
16. ALL CIRCUIT BREAKERS SHALL BE BRAND NEW BOLT-ON TYPE, PANELBOARDS SHOULD
BE PROVIDED WITH GROUND BUS BAR AND DIRECTORY.
17. IN GROUND ROD AND CABLE CONNECTION, USE CADWELD METHOD.