Professional Documents
Culture Documents
3/2
direct operated
core disc
1/4
Series
NC
320
NO
FEATURES
s
s
s
s
Three way solenoid valves with orifice and pipe connections in valve body
Valves are designed to handle relatively high pressure 3-way applications
Valves do not require a minimum operating pressure
The solenoid valves satisfy all relevant EC Directives
GENERAL
Differential pressure
Maximum viscosity
Response times
fluids ()
seal materials ()
-20 to + 90C
-20 to + 40C
NBR (nitrile)
UR (urethane)
Brass body
Brass
Stainless steel
Stainless steel
Stainless steel
NBR
NBR or UR
CA
Copper
\1
BP
MP
RP
LP
Not
Available
Not
Available
Not
Available
10,5W-16,7W
Low
power
Reduced
power
Medium
power
Basic
power
SPECIFICATIONS
operating pressure
differential (bar)
max. (PS)
min. air/water()
~
=
(mm) (m3/h) (l/m)
flow
pipe orifice
coefficient
size size
Kv
NPT
power
level
BP
~/=
EF
ATEX / IECEx
IP65
Ex d Ex e mb Ex mb EEx nA
NF
EM
PV
ZN
SC
brass
stainless st.
U - Universal
1/4
0,8
1,6
2,4
0,02
0,08
0,10
0,3
1,3
1,7
0
0
0
27
9
7
19
5
4
16,7/11,2
10,5/11,2
16,7/11,2
l
l
l
l
l
l
m
l
m
l
l
l
l
l
l
l
l
l
8320A170
8320A172
8320B174
(1)
8320A200
0
0
0
0
50
15
10
6
35
11
8
4
16,7/11,2
16,7/11,2
10,5/11,2
10,5/11,2
l
l
l
l
l
l
l
l
m
m
l
l
l
l
l
l
l
l
l
l
l
l
l
l
8320A180
8320A182
8320A184
8320A186
(1)
8320A202
8320A203
0
0
0
0
55
17
10
5
40
11
7
4
16,7/11,2
16,7/11,2
10,5/11,2
10,5/11,2
l
l
l
l
l
l
l
l
m
m
l
l
l
l
l
l
l
l
l
l
l
l
l
l
8320A190
8320A192
8320A194
8320A196
(1)
8320A204
8320A205
NC - Normally closed
1/4
0,8
1,6
2,4
3,2
0,02
0,08
0,10
0,21
0,3
1,3
1,7
3,5
1/4
0,8
1,6
2,4
3,2
0,02
0,08
0,10
0,21
L Available feature
0,3
1,3
1,7
3,5
- Not available
(1)
UR discs
2011/R\0\iINDIA
NO - Normally open
SERIES 320
PRODUCT SELECTION GUIDE
PREFIX TABLE
STEP 1
Select basic catalogue number,
including pipe thread indentification
letter. Refer to the specifications table
on page 1.
Example: B320A202
prefix
power level
description
LP RP MP BP
1 2 3 4 5 6 7
S C
D U
Dustproof (EN 50281-1-1)*
- - - l
E F
Explosionproof - NEMA 7, 9 - Zinc plated steel conduit
- - - l
E V
Explosionproof - NEMA 7, 9 - 316 SS conduit
- - - l
E M
Waterproof IP67 - Metal enclosure (EN/IEC 60079-7+18, 61241-1)*
- - - l
E T
Threaded conduit/hole (M20 x 1,5)
- - - l
I S
S C
Intrinsically safe with SC coil (EN/IEC 60079-11+26, 61241-11)*
- - - N F
Flameproof - Aluminium (EN/IEC 60079-1, 61241-1)*
- - - l
P V
Encapsulated epoxy moulded (EN/IEC 60079-18, 61241-18)*
- - - l
S C
Solenoid with spade plug connector (EN/IEC 60730)
- - - l
W P
Waterproof IP67 - Metal enclosure
- - - l
W P
D U
Waterproof IP67 - Metal enclosure, Dustproof (EN 50281-1-1)*
- - - l
W P
I S
I.S. with Metal IP67 enclosure (EN/IEC 60079-11+26, 61241-11)*
- - - W P
Z N
Waterproof IP67 - Metal enclosure (EN 50021, 50281-1-1)*
- - - l
W S
Waterproof IP67 - 316 SS enclosure
- - - l
W S
D U
Waterproof IP67 - 316 SS enclosure, Dustproof (EN 50281-1-1)*
- - - l
W S E M
Waterproof IP67 - 316 SS enclosure (EN/IEC 60079-7+18, 61241-1)* - - - l
W S
I S
I.S. with 316 SS IP67 enclosure (EN/IEC 60079-11+26, 61241-11)*
- - - W S N F
Flameproof - 316 SS (EN/IEC 60079-1, 61241-1)*
- - - l
W S Z N
Waterproof IP67 - 316 SS enclosure (EN 50021, 50281-1-1)*
- - - l
T
Threaded conduit (1/2" NPT)
- - - l
H C
Class H - Battery charging circuit
- - - l
H T
Class H - High temperature
- - - l
Z N
Moulded enclosure (EN 50021, 50281-1-1)*
- - - l
X Other special constructions
- - - l
STEP 2
Select prefix (combination). Refer to
the specifications table on page 1 and
the prefix table on page 2, respect the
indicated power level.
Example: PV
STEP 3
Select suffix (combination) if required.
Refer to the suffix table on page 2,
respect the indicated power level.
Example: T
STEP 4
Select voltage. Refer to standard
voltages on page 3.
Example: 24V / DC
SUFFIX TABLE
description
EPDM (ethylene-propylene)
CR (chloroprene)
Oxygen service (CR (chloroprene))
FPM (fluoroelastomer) and parts cleaned for oxygen service
PTFE (polytetrafluoroethylene)
FPM (fluoroelastomer)
UR (urethane)
Epoxy coating on all external surfaces
Mounting bracket
Dry gas, non-lubricated air construction
Long life, quiet operation construction
Push type manual operator
Screw type manual operator
L Available feature
t Standard feature for B320A170, B320A180 and B320A190
- Not available
* ATEX solenoids are also approved according to EN 13463-1 (non electrical valves)
8
8
8
8
8
8
8
EF 8
8 320A170
8 320A172
8 320B174
8 320A180
8 320A182
8 320A184
8 320A186
8 320A190
8 320A192
8 320A194
8 320A196
8 320A200
8 320A202
8 320A203
8 320A204
8 320A205
C302112
C302114
C302116
C302140
C302141
C302142
C302143
C302182
C302183
C302184
C302184
C312189
C312191
C312191
C312193
C312193
C302200
C302201
C302201
C302226
C302227
C302227
C302228
C302254
C302255
C302255
C302255
C312190
C312192
C312192
C312194
C312194
mouting
bracket no.
160800 (2)
160800 (2)
160800 (2)
160800 (2)
160800 (2)
160800 (2)
160800 (2)
160800 (2)
160800 (2)
160800 (2)
160800 (2)
162950-001(3)
162950-001(3)
162950-001(3)
162950-001(3)
162950-001(3)
STEP 5
Final catalogue / ordering number.
Example:
PV8320A202 T 24V / DC
power level
LP RP MP BP
- - - l
- - - l
- - - l
- - - l
- - - l
- - - l
- - - t
- - - l
- - - l
- - - l
- - - l
- - - l
- - - l
320 A192
320 A184
320 A194
320 A170
320 A182
320 B174
320 A190
320 G200
V
MB
MS
VP
Q
CO
MO
230V / 50 Hz
230V / 50 Hz
24V / DC
24V / DC
24V / DC
230V / 50 Hz
230V / 50 Hz
240V / 60 Hz
prefix (4)
pipe thread
basic number (4)
voltage
suffix
(5)
suffix
2011/R0\INDIA
suffix
1 2 3 4 5
E
J
N
N V
T
V
W
C O
M B
P
Q
M O
M S
SERIES 320
EXPLANATION OF TEMPERATURE RANGES OF SOLENOID VALVES
Valve temperature range
Operator ambient temperature range
Total temperature range
The valve temperature range (TS) is determined by the selected seal material, the temperature
range for proper operation of the valve and sometimes by the fluid (e.g. steam)
The operator ambient temperature range is determined by the selected power level and the
safety code
The temperature range of the complete solenoid valve is determined by the limitations of both
temperature ranges above
ELECTRICAL CHARACTERISTICS
Coil insulation class
Electrical safety
Standard voltages
F
IEC 335
DC (=) 24V - 48V
AC (~) 24V - 48V - 115V - 230V/50Hz; other voltages and 60Hz are available on request
(VA)
Basic power (BP)
(VA)
(W)
(W)
operator
ambient
temperature
range
(C)(1)
SC
SC
WP/WS
WP/WS
NF/WSNF
NF/WSNF
NF/WSNF
EM/WSEM
PV
EF
EF
ZN
ZN
WPZN/WSZN
WPZN/WSZN
WPZN/WSZN
23,0
35,0
23,0
35,0
23,0
35,0
23,0
23,0
25,0
40,0
23,0
35,0
23,0
35,0
10,5
16,7
10,5
16,7
10,5
16,7
10,5
10,5
10,1
17,1
10,5
16,7
10,5
16,7
9,0/11,2
9,0/11,2
9,0/11,2
9,0/11,2
9,0/11,2
9,0/11,6
9,0/11,2
9,0/11,2
-
-40 to +75
-40 to +50
-40 to +75
-40 to +50
-60 to+25/40/60
-60 to+40/60/75
-60 to +40
-40 to +40
-40 to +65
-40 to +52/40
-40 to +52
-20 to +50
-20 to +50
-40 to +60/75
-40 to +75
-40 to +40
power ratings
prefix
option
(1)
(2)
inrush
~
55,0
78,0
55,0
78,0
55,0
78,0
55,0
55,0
50,0
70,0
55,0
78,0
55,0
78,0
holding
~
hot/cold
=
safety code
EN 60730
EN 60730
EN 60730
EN 60730
II2G Ex d IIC T6/T5/T4, II2D Ex tD
II2G Ex d IIC T6/T5/T4, II2D Ex tD
II2G Ex d IIC T4, II2D Ex tD
II2G Ex e mb II T3, II2D Ex tD
II 2G/D Ex mb II T3(~)/T4(=)/Ex mD
NEMA type 7 and 9
NEMA type 7 and 9
II3GD EEx nA II T3
II3GD EEx nA II T3
II3GD EEx nA II T4/T3
II3GD EEx nA II T3
II3GD EEx nA II T3
electrical
enclosure
protection
(EN 60529)
230V/50 Hz
24V/DC
type(2)
(3)
Multiple coil kits are available under ATEX/IECEx, contact us
- Not available
ELECTRICAL CONNECTIONS
prefix
SC, ZN
WP, WS, EM, WSEM,
WPDU, WSDU
NF, WSNF
PV
connection
Spade plug connector with cable gland EN175301-803A (ISO 4400) for cables with an outer diameter
from 6 to 10 mm.
M22 cable gland for cables with an outer diameter from 7 to 12 mm. With an internal and external
facility for an earthing or bonding conductor.
1/2" NPT threaded cable entry. Enclosures are supplied without cable gland.
Moulded-in cable, standard length 2 m
ADDITIONAL OPTIONS