You are on page 1of 52

Cat Electronic Technician 2013C v1.

0
Product Status Report
8/20/2014 10:24 AM
Product Status Report
Parameter
Engine Serial Number
Equipment ID
Comments

Value
1HZ03948
NBR00416
CO1 BEFORE
WHITE SMOKE

EMCP 4.2
Parameter
ECM Part Number
ECM Serial Number
Software Group Part Number
Software Group Release Date
Software Group Description

Value
3518758-02
0312B066TX
3911270-00
NOV2011
A5L1_1_1_1_Prod_Complex English, 4.1.1c
PROD, 08November2011

Logged Diagnostic Codes [Diagnostic Clock = 4973 hours] - EMCP 4.2


Code
3543- 9

Description
Engine Operating State :
Abnormal Update Rate

Occ.
2

SMH First SMH Last RTC First RTC Last


4640:16:33 4950:40:33 6/23/2014 7/15/2014
2:36:51 AM 10:34:40
AM

Logged Event Codes [Diagnostic Clock = 4973 hours] - EMCP 4.2


Code
110- 0

Description
Engine Coolant
Temperature : High most severe (3)
Engine Coolant
Temperature : High - least
severe (1)
Engine Speed : Low most severe (3)

Occ.
4

190-17

Engine Speed : Low least severe (1)

702-31

Auxiliary I/O #02

15

703-31

Auxiliary I/O #03

970-31

Engine Auxiliary Engine


Shutdown Switch

110-15
190- 1

4
2

SMH First SMH Last RTC First RTC Last


4764:24:25 4950:41:54 7/5/2014
7/15/2014
3:10:05 AM 10:32:35
AM
4764:24:25 4950:41:54 7/5/2014
7/15/2014
3:09:07 AM 10:31:09
AM
4927:19:37 4950:41:34 7/14/2014 7/15/2014
1:15:28 AM 10:28:59
AM
4927:19:33 4950:41:30 7/14/2014 7/15/2014
1:15:24 AM 10:28:55
AM
4640:01:33 4802:49:25 6/22/2014 7/7/2014
7:47:46 PM 7:15:07 PM
4693:49:03 4972:38:41 6/28/2014 7/19/2014
1:10:25 AM 5:34:42 AM
4640:01:33 4972:40:33 6/22/2014 7/19/2014
11:47:56
7:36:53 PM
PM

2448-15
2456-15
2648-31
4007-31
4256-17

Generator Average AC
2
RMS Current : High least severe (1)
Generator Total Reactive 1
Power : High - least
severe (1)
Maintenance Lamp
99
Generator Control not in
Automatic
Cranking Voltage : Low least severe (1)

54
2

4850:59:56 4851:01:31 7/10/2014 7/10/2014


5:01:01 PM 5:02:36 PM
4676:12:36 4676:12:36 6/24/2014 6/24/2014
8:02:43 PM 8:02:43 PM
500:00:02

4640:01:33 6/17/2012
4:20:44 AM
4640:01:33 4972:40:33 6/22/2014
7:20:15 PM
4972:37:33 4972:37:33 7/19/2014
4:29:58 AM

6/22/2014
7:44:10 PM
7/19/2014
8:05:07 PM
7/19/2014
4:30:18 AM

Active Diagnostic Codes - EMCP 4.2


Code
No Active
Codes

Description

Active Event Codes - EMCP 4.2


Code
4007-31

Description
Generator Control not in Automatic

Current Totals - EMCP 4.2


Description
Total Operating Hours
Generator Total kW Hours
Export

Value
4972.7
6858763

Unit
hours
KW-hr

Configuration - EMCP 4.2


Description
Analog Input #1 Signal Type
Analog Input #1 Signal Range
Analog Input #1 Configuration Code
Analog Input #1 Data Identification
Analog Input #1 Minimum Data Range
Analog Input #1 Maximum Data Range
Analog Input #1 High Warning Event
Threshold
Analog Input #1 High Warning Event Delay
Time
Analog Input #1 High Shutdown Event
Threshold
Analog Input #1 High Shutdown Event
Delay Time
Analog Input #1 Low Warning Event
Threshold
Analog Input #1 Low Warning Event Delay
Time
Analog Input #1 Low Shutdown Event
Threshold
Analog Input #1 Low Shutdown Event
Delay Time

Value
Disabled
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed

Unit

Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed

sec

Analog Input #2 Signal Type


Analog Input #2 Signal Range
Analog Input #2 Configuration Code
Analog Input #2 Data Identification
Analog Input #2 Minimum Data Range
Analog Input #2 Maximum Data Range
Analog Input #2 High Warning Event
Threshold
Analog Input #2 High Warning Event Delay
Time
Analog Input #2 High Shutdown Event
Threshold
Analog Input #2 High Shutdown Event
Delay Time
Analog Input #2 Low Warning Event
Threshold
Analog Input #2 Low Warning Event Delay
Time
Analog Input #2 Low Shutdown Event
Threshold
Analog Input #2 Low Shutdown Event
Delay Time
Analog Input #3 Signal Type
Analog Input #3 Signal Range
Analog Input #3 Configuration Code
Analog Input #3 Data Identification
Analog Input #3 Minimum Data Range
Analog Input #3 Maximum Data Range
Analog Input #3 High Warning Event
Threshold
Analog Input #3 High Warning Event Delay
Time
Analog Input #3 High Shutdown Event
Threshold
Analog Input #3 High Shutdown Event
Delay Time
Analog Input #3 Low Warning Event
Threshold
Analog Input #3 Low Warning Event Delay
Time
Analog Input #3 Low Shutdown Event
Threshold
Analog Input #3 Low Shutdown Event
Delay Time
Analog Input Supply Voltage
Engine Start Fault Protection Activation
Delay Time
Crank Duration
Crank Cycle Rest Interval
Engine Purge Cycle Time
Maximum Number of Crank Cycles
Cooldown Duration

Disabled
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed

sec

Disabled
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed

sec

5 Volt
30

sec

10
10
0
5
0

sec
sec
sec
min

Start Aid Activation Time


Crank Alert Activation Time
Crank Terminate RPM
Engine Fuel Type Configuration
Fuel Shutoff Solenoid Type Configuration
Engine Cooldown Speed Configuration
Engine Operating State Input Configuration
Fuel Priming Feature Enable Status
Engine Forced Idle Feature Enable Status
Emergency Stop Switch Active State
Configuration
High Battery Voltage Warning Event
Threshold
High Battery Voltage Warning Event
Notification Delay Time
High Battery Voltage Shutdown Event
Threshold
High Battery Voltage Shutdown Event
Notification Delay Time
Low Battery Voltage Warning Event
Threshold
Low Battery Voltage Warning Event
Notification Delay Time
Low Battery Charging System Voltage
Warning Event Threshold
Low Battery Charging System Voltage
Warning Event Notification Delay Time
Low Cranking Voltage Warning Event
Threshold
Low Cranking Voltage Warning Event
Notification Delay Time
Customer Password Security Level to
Reset Crank/Start Counters
SCADA Data Link Baud Rate
SCADA Data Link Parity
SCADA Data Link Slave Address
SCADA Data Link Access Password
RS-485 Bias Resistor Enable Status
Digital Input #1 Usage Type
Digital Input #1 Active State Configuration
Digital Input #1 Command/Status
Parameter Data Identification
Event Input Function #1 Event Notification
Delay Time
Event Input Function #1 Suspect
Parameter Number
Event Input Function #1 Failure Mode
Identifier
Digital Input #2 Usage Type
Digital Input #2 Active State Configuration
Digital Input #2 Command/Status
Parameter Data Identification

0
0
400
Diesel
Energized to Run
Rated Speed
Hardwired Input
Disabled
Enabled
High

sec
sec
rpm

29.4

Volts

30

sec

32.0

Volts

sec

18.0

Volts

10

sec

23.0

Volts

30

sec

20.0

Volts

sec

3-Factory, Single Use


19200 baud
None
1
00000000
Enabled
Command/Status Parameter
Low
Idle Mode Command
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
System Event
Low
Disabled or Not Installed

sec

Event Input Function #2 Event Notification


Delay Time
Event Input Function #2 Suspect
Parameter Number
Event Input Function #2 Failure Mode
Identifier
Digital Input #3 Usage Type
Digital Input #3 Active State Configuration
Digital Input #3 Command/Status
Parameter Data Identification
Event Input Function #3 Event Notification
Delay Time
Event Input Function #3 Suspect
Parameter Number
Event Input Function #3 Failure Mode
Identifier
Digital Input #4 Usage Type
Digital Input #4 Active State Configuration
Digital Input #4 Command/Status
Parameter Data Identification
Event Input Function #4 Event Notification
Delay Time
Event Input Function #4 Suspect
Parameter Number
Event Input Function #4 Failure Mode
Identifier
Digital Input #5 Usage Type
Digital Input #5 Active State Configuration
Digital Input #5 Command/Status
Parameter Data Identification
Event Input Function #5 Event Notification
Delay Time
Event Input Function #5 Suspect
Parameter Number
Event Input Function #5 Failure Mode
Identifier
Digital Input #6 Usage Type
Digital Input #6 Active State Configuration
Digital Input #6 Command/Status
Parameter Data Identification
Event Input Function #6 Event Notification
Delay Time
Event Input Function #6 Suspect
Parameter Number
Event Input Function #6 Failure Mode
Identifier
Digital Output #1 Usage Type
Digital Output #1 Command/Status
Parameter Data Identification
Digital Output #1 Event Suspect Parameter
Number
Digital Output #1 Event Trigger Condition
Digital Output #2 Usage Type

sec

Custom Event
Condition Exists
System Event
Low
Disabled or Not Installed
0

sec

Custom Event
Condition Exists
Disabled
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Command/Status Parameter
Low
Nominal Frequency Selection is Low
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Command/Status Parameter
Disable Aux AC Supply
Disabled or Not Installed
Disabled or Not Installed
Command/Status Parameter

sec

Digital Output #2 Command/Status


Parameter Data Identification
Digital Output #2 Event Suspect Parameter
Number
Digital Output #2 Event Trigger Condition
Engine Coolant Temperature Sensor
Configuration
High Engine Coolant Temperature Warning
Event Threshold
High Engine Coolant Temperature Warning
Event Notification Delay Time
High Engine Coolant Temperature
Shutdown Event Threshold
High Engine Coolant Temperature
Shutdown Event Notification Delay Time
Low Engine Coolant Temperature Warning
Event Threshold
Low Engine Coolant Temperature Warning
Event Notification Delay Time
Engine Oil Pressure Sensor Configuration
Low Engine Oil Pressure Warning Event
Threshold
Low Idle Low Engine Oil Pressure Warning
Event Threshold
Low Engine Oil Pressure Warning Event
Notification Delay Time
Low Engine Oil Pressure Shutdown Event
Threshold
Low Idle Low Engine Oil Pressure
Shutdown Event Threshold
Low Engine Oil Pressure Shutdown Event
Notification Delay Time
Low Engine Oil Pressure Step Speed
Flywheel Teeth
Engine Overspeed Setpoint
Engine Underspeed Warning Event
Threshold
Engine Underspeed Warning Event
Notification Delay Time
Engine Underspeed Shutdown Event
Threshold
Engine Underspeed Shutdown Event
Notification Delay Time
Engine Speed Sensor Configuration
Generator Drive Ratio
Engine Cylinder Temperature Sensor
Installation Status
Number of Engine Cylinders
Generator Winding Temperature Sensor
Installation Status
Generator Bearing Temperature Sensor
Installation Configuration

Run Mode
Disabled or Not Installed
Disabled or Not Installed
Data Link
216

Deg F

sec

225

Deg F

10

sec

70

Deg F

sec

Data Link
35

psi

15

psi

sec

30

psi

10

psi

sec

1200
183
1770
1290

rpm

2.0

sec

1230

rpm

5.0

sec

Sensor
1.000
Not Installed

Ratio

16
Not Installed
Not Installed

rpm
rpm

Accessory Data Link Diagnostic Response


Configuration
Accessory Data Link Diagnostic Audible
Alert
Accessory Data Link Diagnostic Breaker #1
Trip
Accessory Data Link Diagnostic Breaker #2
Trip
Engine Speed Sensor Diagnostic
Response Configuration
Engine Speed Sensor Diagnostic Audible
Alert
Engine Speed Sensor Diagnostic Breaker
#1 Trip
Engine Speed Sensor Diagnostic Breaker
#2 Trip
Primary Data Link Diagnostic Response
Configuration
Primary Data Link Diagnostic Audible Alert
Primary Data Link Diagnostic Breaker #1
Trip
Primary Data Link Diagnostic Breaker #2
Trip
RS-485 SCADA Data Link Diagnostic
Response Configuration
RS-485 SCADA Data Link Diagnostic
Audible Alert
RS-485 SCADA Data Link Diagnostic
Breaker #1 Trip
RS-485 SCADA Data Link Diagnostic
Breaker #2 Trip
RS-485 SCADA Data Link Diagnostic Fault
Protection Timer
RS-485 Annunciator Data Link Diagnostic
Response Configuration
RS-485 Annunciator Data Link Diagnostic
Audible Alert
RS-485 Annunciator Data Link Diagnostic
Breaker #1 Trip
RS-485 Annunciator Data Link Diagnostic
Breaker #2 Trip
RS-485 Annunciator Data Link Diagnostic
Fault Protection Timer
Battery Charger Failure Diagnostic
Response Configuration
Battery Charger Failure Diagnostic Audible
Alert
Engine Controller Not Responding
Diagnostic Response Configuration
Engine Controller Not Responding
Diagnostic Audible Alert
Engine Controller Not Responding
Diagnostic Breaker #1 Trip

Activate Warning Condition


No
No
No
Activate Hard Shutdown Condition
No
No
No
Activate Warning Condition
No
No
No
Activate Warning Condition
No
No
No
No
Activate Warning Condition
No
No
No
No
Activate Warning Condition
No
Activate Warning Condition
No
No

Engine Controller Not Responding


Diagnostic Breaker #2 Trip
Analog Input #1 Diagnostic Response
Configuration
Analog Input #1 Diagnostic Audible Alert
Analog Input #1 Diagnostic Breaker #1 Trip
Analog Input #1 Diagnostic Breaker #2 Trip
Analog Input #2 Diagnostic Response
Configuration
Analog Input #2 Diagnostic Audible Alert
Analog Input #2 Diagnostic Breaker #1 Trip
Analog Input #2 Diagnostic Breaker #2 Trip
Analog Input #3 Diagnostic Response
Configuration
Analog Input #3 Diagnostic Audible Alert
Analog Input #3 Diagnostic Breaker #1 Trip
Analog Input #3 Diagnostic Breaker #2 Trip
Air Damper Closed Event Response
Configuration
Air Damper Closed Event Audible Alert
Emergency Stop Activated Event
Response Configuration
Emergency Stop Activated Event Audible
Alert
Emergency Stop Activated Event Breaker
#1 Trip
Emergency Stop Activated Event Breaker
#2 Trip
High Engine Coolant Level Warning Event
Response Configuration
High Engine Coolant Level Warning Event
Audible Alert
High Engine Coolant Level Warning Event
Breaker #1 Trip
High Engine Coolant Level Warning Event
Breaker #2 Trip
High Engine Coolant Level Shutdown
Event Response Configuration
High Engine Coolant Level Shutdown
Event Audible Alert
High Engine Coolant Level Shutdown
Event Breaker #1 Trip
High Engine Coolant Level Shutdown
Event Breaker #2 Trip
Low Engine Coolant Level Warning Event
Response Configuration
Low Engine Coolant Level Warning Event
Audible Alert
Low Engine Coolant Level Warning Event
Breaker #1 Trip
Low Engine Coolant Level Warning Event
Breaker #2 Trip

No
Activate Warning Condition
No
No
No
Activate Warning Condition
No
No
No
Activate Warning Condition
No
No
No
Disable Condition
No
Activate Hard Shutdown Condition
No
No
No
Activate Warning Condition
No
No
No
Activate Hard Shutdown Condition
No
No
No
Activate Warning Condition
No
No
No

Low Engine Coolant Level Shutdown Event


Response Configuration
Low Engine Coolant Level Shutdown Event
Audible Alert
Low Engine Coolant Level Shutdown Event
Breaker #1 Trip
Low Engine Coolant Level Shutdown Event
Breaker #2 Trip
High Engine Coolant Temperature Warning
Event Response Configuration
High Engine Coolant Temperature Warning
Event Audible Alert
High Engine Coolant Temperature Warning
Event Breaker #1 Trip
High Engine Coolant Temperature Warning
Event Breaker #2 Trip
High Engine Coolant Temperature Warning
Event Fault Protection Timer
High Engine Coolant Temperature
Shutdown Event Response Configuration
High Engine Coolant Temperature
Shutdown Event Audible Alert
High Engine Coolant Temperature
Shutdown Event Breaker #1 Trip
High Engine Coolant Temperature
Shutdown Event Breaker #2 Trip
High Engine Coolant Temperature
Shutdown Event Fault Protection Timer
Low Engine Coolant Temperature Warning
Event Response Configuration
Low Engine Coolant Temperature Warning
Event Audible Alert
Low Engine Coolant Temperature Warning
Event Breaker #1 Trip
Low Engine Coolant Temperature Warning
Event Breaker #2 Trip
Low Engine Coolant Temperature Warning
Event Fault Protection Timer
Engine Failure To Start Shutdown Event
Response Configuration
Engine Failure To Start Shutdown Event
Audible Alert
Engine Failure To Start Shutdown Event
Breaker #1 Trip
Engine Failure To Start Shutdown Event
Breaker #2 Trip
High Engine Oil Level Warning Event
Response Configuration
High Engine Oil Level Warning Event
Audible Alert
High Engine Oil Level Warning Event
Breaker #1 Trip
High Engine Oil Level Warning Event
Breaker #2 Trip

Activate Hard Shutdown Condition


No
No
No
Activate Warning Condition
No
No
No
No
Activate Hard Shutdown Condition
No
No
No
No
Activate Warning Condition
No
No
No
No
Activate Hard Shutdown Condition
No
No
No
Activate Warning Condition
No
No
No

High Engine Oil Level Shutdown Event


Response Configuration
High Engine Oil Level Shutdown Event
Audible Alert
High Engine Oil Level Shutdown Event
Breaker #1 Trip
High Engine Oil Level Shutdown Event
Breaker #2 Trip
Low Engine Oil Level Warning Event
Response Configuration
Low Engine Oil Level Warning Event
Audible Alert
Low Engine Oil Level Warning Event
Breaker #1 Trip
Low Engine Oil Level Warning Event
Breaker #2 Trip
Low Engine Oil Level Shutdown Event
Response Configuration
Low Engine Oil Level Shutdown Event
Audible Alert
Low Engine Oil Level Shutdown Event
Breaker #1 Trip
Low Engine Oil Level Shutdown Event
Breaker #2 Trip
Low Engine Oil Pressure Warning Event
Response Configuration
Low Engine Oil Pressure Warning Event
Audible Alert
Low Engine Oil Pressure Warning Event
Breaker #1 Trip
Low Engine Oil Pressure Warning Event
Breaker #2 Trip
Low Engine Oil Pressure Warning Event
Fault Protection Timer
Low Engine Oil Pressure Shutdown Event
Response Configuration
Low Engine Oil Pressure Shutdown Event
Audible Alert
Low Engine Oil Pressure Shutdown Event
Breaker #1 Trip
Low Engine Oil Pressure Shutdown Event
Breaker #2 Trip
Low Engine Oil Pressure Shutdown Event
Fault Protection Timer
High Engine Oil Temperature Warning
Event Response Configuration
High Engine Oil Temperature Warning
Event Audible Alert
High Engine Oil Temperature Warning
Event Breaker #1 Trip
High Engine Oil Temperature Warning
Event Breaker #2 Trip
High Engine Oil Temperature Warning
Event Fault Protection Timer

Activate Hard Shutdown Condition


No
No
No
Activate Warning Condition
No
No
No
Activate Hard Shutdown Condition
No
No
No
Activate Warning Condition
No
No
No
Yes
Activate Hard Shutdown Condition
No
No
No
Yes
Activate Warning Condition
No
No
No
No

High Engine Oil Temperature Shutdown


Event Response Configuration
High Engine Oil Temperature Shutdown
Event Audible Alert
High Engine Oil Temperature Shutdown
Event Breaker #1 Trip
High Engine Oil Temperature Shutdown
Event Breaker #2 Trip
High Engine Oil Temperature Shutdown
Event Fault Protection Timer
Low Engine Oil Temperature Warning
Event Response Configuration
Low Engine Oil Temperature Warning
Event Audible Alert
Low Engine Oil Temperature Warning
Event Breaker #1 Trip
Low Engine Oil Temperature Warning
Event Breaker #2 Trip
Low Engine Oil Temperature Warning
Event Fault Protection Timer
Low Engine Oil Temperature Shutdown
Event Response Configuration
Low Engine Oil Temperature Shutdown
Event Audible Alert
Low Engine Oil Temperature Shutdown
Event Breaker #1 Trip
Low Engine Oil Temperature Shutdown
Event Breaker #2 Trip
Low Engine Oil Temperature Shutdown
Event Fault Protection Timer
Unexpected Engine Shutdown Event
Response Configuration
Unexpected Engine Shutdown Event
Audible Alert
Unexpected Engine Shutdown Event
Breaker #1 Trip
Unexpected Engine Shutdown Event
Breaker #2 Trip
Engine Overspeed Shutdown Event
Response Configuration
Engine Overspeed Shutdown Event
Audible Alert
Engine Overspeed Shutdown Event
Breaker #1 Trip
Engine Overspeed Shutdown Event
Breaker #2 Trip
Engine Underspeed Warning Event
Response Configuration
Engine Underspeed Warning Event Audible
Alert
Engine Underspeed Warning Event
Breaker #1 Trip
Engine Underspeed Warning Event
Breaker #2 Trip

Activate Hard Shutdown Condition


No
No
No
No
Activate Warning Condition
No
No
No
Yes
Disable Condition
No
No
No
Yes
Activate Hard Shutdown Condition
No
No
No
Activate Hard Shutdown Condition
No
No
No
Activate Warning Condition
No
No
No

Engine Underspeed Warning Event Fault


Protection Timer
Engine Underspeed Shutdown Event
Response Configuration
Engine Underspeed Shutdown Event
Audible Alert
Engine Underspeed Shutdown Event
Breaker #1 Trip
Engine Underspeed Shutdown Event
Breaker #2 Trip
Engine Underspeed Shutdown Event Fault
Protection Timer
High Exhaust Temperature Warning Event
Response Configuration
High Exhaust Temperature Warning Event
Audible Alert
High Exhaust Temperature Warning Event
Breaker #1 Trip
High Exhaust Temperature Warning Event
Breaker #2 Trip
High Exhaust Temperature Warning Event
Fault Protection Timer
High Exhaust Temperature Shutdown
Event Response Configuration
High Exhaust Temperature Shutdown
Event Audible Alert
High Exhaust Temperature Shutdown
Event Breaker #1 Trip
High Exhaust Temperature Shutdown
Event Breaker #2 Trip
High Exhaust Temperature Shutdown
Event Fault Protection Timer
Low Exhaust Temperature Warning Event
Response Configuration
Low Exhaust Temperature Warning Event
Audible Alert
Low Exhaust Temperature Warning Event
Breaker #1 Trip
Low Exhaust Temperature Warning Event
Breaker #2 Trip
Low Exhaust Temperature Warning Event
Fault Protection Timer
Low Exhaust Temperature Shutdown Event
Response Configuration
Low Exhaust Temperature Shutdown Event
Audible Alert
Low Exhaust Temperature Shutdown Event
Breaker #1 Trip
Low Exhaust Temperature Shutdown Event
Breaker #2 Trip
Low Exhaust Temperature Shutdown Event
Fault Protection Timer
High Fuel Level Warning Event Response
Configuration

Yes
Activate Hard Shutdown Condition
No
No
No
Yes
Activate Warning Condition
No
No
No
No
Activate Hard Shutdown Condition
No
No
No
No
Activate Warning Condition
No
No
No
No
Disable Condition
No
No
No
No
Activate Warning Condition

High Fuel Level Warning Event Audible


Alert
High Fuel Level Warning Event Breaker #1
Trip
High Fuel Level Warning Event Breaker #2
Trip
High Fuel Level Shutdown Event Response
Configuration
High Fuel Level Shutdown Event Audible
Alert
High Fuel Level Shutdown Event Breaker
#1 Trip
High Fuel Level Shutdown Event Breaker
#2 Trip
Low Fuel Level Warning Event Response
Configuration
Low Fuel Level Warning Event Audible
Alert
Low Fuel Level Warning Event Breaker #1
Trip
Low Fuel Level Warning Event Breaker #2
Trip
Low Fuel Level Shutdown Event Response
Configuration
Low Fuel Level Shutdown Event Audible
Alert
Low Fuel Level Shutdown Event Breaker
#1 Trip
Low Fuel Level Shutdown Event Breaker
#2 Trip
External Tank High Fuel Level Warning
Event Response Configuration
External Tank High Fuel Level Warning
Event Audible Alert
External Tank High Fuel Level Warning
Event Breaker #1 Trip
External Tank High Fuel Level Warning
Event Breaker #2 Trip
External Tank High Fuel Level Shutdown
Event Response Configuration
External Tank High Fuel Level Shutdown
Event Audible Alert
External Tank High Fuel Level Shutdown
Event Breaker #1 Trip
External Tank High Fuel Level Shutdown
Event Breaker #2 Trip
External Tank Low Fuel Level Warning
Event Response Configuration
External Tank Low Fuel Level Warning
Event Audible Alert
External Tank Low Fuel Level Warning
Event Breaker #1 Trip
External Tank Low Fuel Level Warning
Event Breaker #2 Trip

No
No
No
Disable Condition
No
No
No
Activate Warning Condition
No
No
No
Activate Hard Shutdown Condition
No
No
No
Disable Condition
No
No
No
Disable Condition
No
No
No
Disable Condition
No
No
No

External Tank Low Fuel Level Shutdown


Event Response Configuration
External Tank Low Fuel Level Shutdown
Event Audible Alert
External Tank Low Fuel Level Shutdown
Event Breaker #1 Trip
External Tank Low Fuel Level Shutdown
Event Breaker #2 Trip
Fuel Leak Event Response Configuration
Fuel Leak Event Audible Alert
Fuel Leak Event Breaker #1 Trip
Fuel Leak Event Breaker #2 Trip
Service Maintenance Interval Warning
Event Response Configuration
Service Maintenance Interval Warning
Event Audible Alert
High Gas Pressure Warning Event
Response Configuration
High Gas Pressure Warning Event Audible
Alert
High Gas Pressure Warning Event Breaker
#1 Trip
High Gas Pressure Warning Event Breaker
#2 Trip
High Gas Pressure Shutdown Event
Response Configuration
High Gas Pressure Shutdown Event
Audible Alert
High Gas Pressure Shutdown Event
Breaker #1 Trip
High Gas Pressure Shutdown Event
Breaker #2 Trip
Low Gas Pressure Warning Event
Response Configuration
Low Gas Pressure Warning Event Audible
Alert
Low Gas Pressure Warning Event Breaker
#1 Trip
Low Gas Pressure Warning Event Breaker
#2 Trip
Low Gas Pressure Shutdown Event
Response Configuration
Low Gas Pressure Shutdown Event
Audible Alert
Low Gas Pressure Shutdown Event
Breaker #1 Trip
Low Gas Pressure Shutdown Event
Breaker #2 Trip
Engine Intake Manifold Charge
Combustion Event Response Configuration
Engine Intake Manifold Charge
Combustion Event Audible Alert
Engine Intake Manifold Charge
Combustion Event Breaker #1 Trip

Disable Condition
No
No
No
Activate Warning Condition
No
No
No
Activate Warning Condition
No
Disable Condition
No
No
No
Disable Condition
No
No
No
Disable Condition
No
No
No
Disable Condition
No
No
No
Activate Hard Shutdown Condition
No
No

Engine Intake Manifold Charge


Combustion Event Breaker #2 Trip
Engine Intake Manifold Charge
Combustion Event Fault Protection Timer
Remote Emergency Stop Activated
Shutdown Event Response Configuration
Remote Emergency Stop Activated
Shutdown Event Audible Alert
Remote Emergency Stop Activated
Shutdown Event Breaker #1 Trip
Remote Emergency Stop Activated
Shutdown Event Breaker #2 Trip
High Generator Bearing #1 Temperature
Warning Event Response Configuration
High Generator Bearing #1 Temperature
Warning Event Audible Alert
High Generator Bearing #1 Temperature
Warning Event Breaker #1 Trip
High Generator Bearing #1 Temperature
Warning Event Breaker #2 Trip
High Generator Bearing #1 Temperature
Warning Event Fault Protection Timer
High Generator Bearing #1 Temperature
Shutdown Event Response Configuration
High Generator Bearing #1 Temperature
Shutdown Event Audible Alert
High Generator Bearing #1 Temperature
Shutdown Event Breaker #1 Trip
High Generator Bearing #1 Temperature
Shutdown Event Breaker #2 Trip
High Generator Bearing #1 Temperature
Shutdown Event Fault Protection Timer
Low Generator Bearing #1 Temperature
Warning Event Response Configuration
Low Generator Bearing #1 Temperature
Warning Event Audible Alert
Low Generator Bearing #1 Temperature
Warning Event Breaker #1 Trip
Low Generator Bearing #1 Temperature
Warning Event Breaker #2 Trip
Low Generator Bearing #1 Temperature
Warning Event Fault Protection Timer
Low Generator Bearing #1 Temperature
Shutdown Event Response Configuration
Low Generator Bearing #1 Temperature
Shutdown Event Audible Alert
Low Generator Bearing #1 Temperature
Shutdown Event Breaker #1 Trip
Low Generator Bearing #1 Temperature
Shutdown Event Breaker #2 Trip
Low Generator Bearing #1 Temperature
Shutdown Event Fault Protection Timer
Generator Overcurrent Warning Event
Response Configuration

No
No
Activate Hard Shutdown Condition
Yes
Yes
Yes
Disable Condition
No
No
No
No
Disable Condition
No
No
No
No
Disable Condition
No
No
No
No
Disable Condition
No
No
No
No
Activate Warning Condition

Generator Overcurrent Warning Event


Audible Alert
Generator Overcurrent Warning Event
Breaker #1 Trip
Generator Overcurrent Warning Event
Breaker #2 Trip
Generator Overcurrent Shutdown Event
Response Configuration
Generator Overcurrent Shutdown Event
Audible Alert
Generator Overcurrent Shutdown Event
Breaker #1 Trip
Generator Overcurrent Shutdown Event
Breaker #2 Trip
Generator Over Frequency Warning Event
Response Configuration
Generator Over Frequency Warning Event
Audible Alert
Generator Over Frequency Warning Event
Breaker #1 Trip
Generator Over Frequency Warning Event
Breaker #2 Trip
Generator Over Frequency Shutdown
Event Response Configuration
Generator Over Frequency Shutdown
Event Audible Alert
Generator Over Frequency Shutdown
Event Breaker #1 Trip
Generator Over Frequency Shutdown
Event Breaker #2 Trip
Generator Under Frequency Warning
Event Response Configuration
Generator Under Frequency Warning
Event Audible Alert
Generator Under Frequency Warning
Event Breaker #1 Trip
Generator Under Frequency Warning
Event Breaker #2 Trip
Generator Under Frequency Warning
Event Fault Protection Timer
Generator Under Frequency Shutdown
Event Response Configuration
Generator Under Frequency Shutdown
Event Audible Alert
Generator Under Frequency Shutdown
Event Breaker #1 Trip
Generator Under Frequency Shutdown
Event Breaker #2 Trip
Generator Under Frequency Shutdown
Event Fault Protection Timer
Generator Reverse Power Warning Event
Response Configuration
Generator Reverse Power Warning Event
Audible Alert

No
No
No
Activate Hard Shutdown Condition
No
No
No
Activate Warning Condition
No
No
No
Activate Soft Shutdown Condition
No
No
No
Activate Warning Condition
No
No
No
Yes
Activate Hard Shutdown Condition
No
No
No
Yes
Activate Warning Condition
No

Generator Reverse Power Warning Event


Breaker #1 Trip
Generator Reverse Power Warning Event
Breaker #2 Trip
Generator Reverse Power Shutdown Event
Response Configuration
Generator Reverse Power Shutdown Event
Audible Alert
Generator Reverse Power Shutdown Event
Breaker #1 Trip
Generator Reverse Power Shutdown Event
Breaker #2 Trip
Generator Over Voltage Warning Event
Response Configuration
Generator Over Voltage Warning Event
Audible Alert
Generator Over Voltage Warning Event
Breaker #1 Trip
Generator Over Voltage Warning Event
Breaker #2 Trip
Generator Over Voltage Shutdown Event
Response Configuration
Generator Over Voltage Shutdown Event
Audible Alert
Generator Over Voltage Shutdown Event
Breaker #1 Trip
Generator Over Voltage Shutdown Event
Breaker #2 Trip
Generator Under Voltage Warning Event
Response Configuration
Generator Under Voltage Warning Event
Audible Alert
Generator Under Voltage Warning Event
Breaker #1 Trip
Generator Under Voltage Warning Event
Breaker #2 Trip
Generator Under Voltage Warning Event
Fault Protection Timer
Generator Under Voltage Shutdown Event
Response Configuration
Generator Under Voltage Shutdown Event
Audible Alert
Generator Under Voltage Shutdown Event
Breaker #1 Trip
Generator Under Voltage Shutdown Event
Breaker #2 Trip
Generator Under Voltage Shutdown Event
Fault Protection Timer
Earth Fault Event Response Configuration
Earth Fault Event Audible Alert
Earth Fault Event Breaker #1 Trip
Earth Fault Event Breaker #2 Trip
Generator Winding #1 High Temperature
Warning Event Response Configuration

No
No
Activate Soft Shutdown Condition
No
No
No
Activate Warning Condition
No
No
No
Activate Soft Shutdown Condition
No
No
No
Activate Warning Condition
No
No
No
Yes
Activate Hard Shutdown Condition
No
No
No
Yes
Activate Hard Shutdown Condition
No
No
No
Disable Condition

Generator Winding #1 High Temperature


Warning Event Audible Alert
Generator Winding #1 High Temperature
Warning Event Breaker #1 Trip
Generator Winding #1 High Temperature
Warning Event Breaker #2 Trip
Generator Winding #1 High Temperature
Warning Event Fault Protection Timer
Generator Winding #1 High Temperature
Shutdown Event Response Configuration
Generator Winding #1 High Temperature
Shutdown Event Audible Alert
Generator Winding #1 High Temperature
Shutdown Event Breaker #1 Trip
Generator Winding #1 High Temperature
Shutdown Event Breaker #2 Trip
Generator Winding #1 High Temperature
Shutdown Event Fault Protection Timer
Generator High Power Warning Event
Response Configuration
Generator High Power Warning Event
Audible Alert
Generator High Power Warning Event
Breaker #1 Trip
Generator High Power Warning Event
Breaker #2 Trip
Generator Reverse Reactive Power
Warning Event Response Configuration
Generator Reverse Reactive Power
Warning Event Audible Alert
Generator Reverse Reactive Power
Warning Event Breaker #1 Trip
Generator Reverse Reactive Power
Warning Event Breaker #2 Trip
Generator Reverse Reactive Power
Shutdown Event Response Configuration
Generator Reverse Reactive Power
Shutdown Event Audible Alert
Generator Reverse Reactive Power
Shutdown Event Breaker #1 Trip
Generator Reverse Reactive Power
Shutdown Event Breaker #2 Trip
High Battery Voltage Warning Event
Response Configuration
High Battery Voltage Warning Event
Audible Alert
High Battery Voltage Warning Event
Breaker #1 Trip
High Battery Voltage Warning Event
Breaker #2 Trip
High Battery Voltage Shutdown Event
Response Configuration
High Battery Voltage Shutdown Event
Audible Alert

No
No
No
No
Activate Hard Shutdown Condition
No
No
No
No
Activate Warning Condition
No
No
No
Activate Warning Condition
No
No
No
Disable Condition
No
No
No
Activate Warning Condition
No
No
No
Activate Soft Shutdown Condition
No

High Battery Voltage Shutdown Event


Breaker #1 Trip
High Battery Voltage Shutdown Event
Breaker #2 Trip
Low Battery Voltage Warning Event
Response Configuration
Low Battery Voltage Warning Event
Audible Alert
Low Battery Voltage Warning Event
Breaker #1 Trip
Low Battery Voltage Warning Event
Breaker #2 Trip
Low Battery Voltage Warning Event Fault
Protection Timer
Low Battery Charging System Voltage
Warning Event Response Configuration
Low Battery Charging System Voltage
Warning Event Audible Alert
Low Battery Charging System Voltage
Warning Event Breaker #1 Trip
Low Battery Charging System Voltage
Warning Event Breaker #2 Trip
Low Battery Charging System Voltage
Warning Event Fault Protection Timer
Generator Breaker Open Event Response
Configuration
Generator Breaker Open Event Audible
Alert
Generator Breaker Closed Event Response
Configuration
Generator Breaker Closed Event Audible
Alert
Engine In Cooldown Event Response
Configuration
Engine In Cooldown Event Audible Alert
Engine Speed-Generator Output Freq
Mismatch Warning Event Response Config
Engine Speed-Generator Output Freq
Mismatch Warning Event Audible Alert
Engine Speed-Generator Output Freq
Mismatch Warning Event Breaker #1 Trip
Engine Speed-Generator Output Freq
Mismatch Warning Event Breaker #2 Trip
Generator Control Not in Automatic
Warning Event Response Configuration
Generator Control Not in Automatic
Warning Event Audible Alert
Emergency Power System Supplying Load
Event Response Configuration
Emergency Power System Supplying Load
Event Audible Alert
Low Cranking Voltage Warning Event
Response Configuration

No
No
Activate Warning Condition
No
No
No
No
Activate Warning Condition
No
No
No
No
Active Only Condition
No
Active Only Condition
No
Active Only Condition
No
Activate Warning Condition
No
No
No
Activate Warning Condition
No
Warning & Active Only Condition
No
Activate Warning Condition

Low Cranking Voltage Warning Event


Audible Alert
Low Cranking Voltage Warning Event
Breaker #1 Trip
Low Cranking Voltage Warning Event
Breaker #2 Trip
Analog Input #1 Custom Parameter High
Warning Event Response Configuration
Analog Input #1 Custom Parameter High
Warning Event Audible Alert
Analog Input #1 Custom Parameter High
Warning Event Breaker #1 Trip
Analog Input #1 Custom Parameter High
Warning Event Breaker #2 Trip
Analog Input #1 Custom Parameter High
Warning Event Fault Protection Timer
Analog Input #1 Custom Parameter High
Shutdown Event Response Configuration
Analog Input #1 Custom Parameter High
Shutdown Event Audible Alert
Analog Input #1 Custom Parameter High
Shutdown Event Breaker #1 Trip
Analog Input #1 Custom Parameter High
Shutdown Event Breaker #2 Trip
Analog Input #1 Custom Parameter High
Shutdown Event Fault Protection Timer
Analog Input #1 Custom Parameter Low
Warning Event Response Configuration
Analog Input #1 Custom Parameter Low
Warning Event Audible Alert
Analog Input #1 Custom Parameter Low
Warning Event Breaker #1 Trip
Analog Input #1 Custom Parameter Low
Warning Event Breaker #2 Trip
Analog Input #1 Custom Parameter Low
Warning Event Fault Protection Timer
Analog Input #1 Custom Parameter Low
Shutdown Event Response Configuration
Analog Input #1 Custom Parameter Low
Shutdown Event Audible Alert
Analog Input #1 Custom Parameter Low
Shutdown Event Breaker #1 Trip
Analog Input #1 Custom Parameter Low
Shutdown Event Breaker #2 Trip
Analog Input #1 Custom Parameter Low
Shutdown Event Fault Protection Timer
Analog Input #2 Custom Parameter High
Warning Event Response Configuration
Analog Input #2 Custom Parameter High
Warning Event Audible Alert
Analog Input #2 Custom Parameter High
Warning Event Breaker #1 Trip
Analog Input #2 Custom Parameter High
Warning Event Breaker #2 Trip

No
No
No
Activate Warning Condition
Yes
No
No
No
Activate Hard Shutdown Condition
Yes
No
No
No
Activate Warning Condition
Yes
No
No
No
Activate Hard Shutdown Condition
Yes
No
No
No
Activate Warning Condition
Yes
No
No

Analog Input #2 Custom Parameter High


Warning Event Fault Protection Timer
Analog Input #2 Custom Parameter High
Shutdown Event Response Configuration
Analog Input #2 Custom Parameter High
Shutdown Event Audible Alert
Analog Input #2 Custom Parameter High
Shutdown Event Breaker #1 Trip
Analog Input #2 Custom Parameter High
Shutdown Event Breaker #2 Trip
Analog Input #2 Custom Parameter High
Shutdown Event Fault Protection Timer
Analog Input #2 Custom Parameter Low
Warning Event Response Configuration
Analog Input #2 Custom Parameter Low
Warning Event Audible Alert
Analog Input #2 Custom Parameter Low
Warning Event Breaker #1 Trip
Analog Input #2 Custom Parameter Low
Warning Event Breaker #2 Trip
Analog Input #2 Custom Parameter Low
Warning Event Fault Protection Timer
Analog Input #2 Custom Parameter Low
Shutdown Event Response Configuration
Analog Input #2 Custom Parameter Low
Shutdown Event Audible Alert
Analog Input #2 Custom Parameter Low
Shutdown Event Breaker #1 Trip
Analog Input #2 Custom Parameter Low
Shutdown Event Breaker #2 Trip
Analog Input #2 Custom Parameter Low
Shutdown Event Fault Protection Timer
Analog Input #3 Custom Parameter High
Warning Event Response Configuration
Analog Input #3 Custom Parameter High
Warning Event Audible Alert
Analog Input #3 Custom Parameter High
Warning Event Breaker #1 Trip
Analog Input #3 Custom Parameter High
Warning Event Breaker #2 Trip
Analog Input #3 Custom Parameter High
Warning Event Fault Protection Timer
Analog Input #3 Custom Parameter High
Shutdown Event Response Configuration
Analog Input #3 Custom Parameter High
Shutdown Event Audible Alert
Analog Input #3 Custom Parameter High
Shutdown Event Breaker #1 Trip
Analog Input #3 Custom Parameter High
Shutdown Event Breaker #2 Trip
Analog Input #3 Custom Parameter High
Shutdown Event Fault Protection Timer
Analog Input #3 Custom Parameter Low
Warning Event Response Configuration

No
Activate Hard Shutdown Condition
Yes
No
No
No
Activate Warning Condition
Yes
No
No
No
Activate Hard Shutdown Condition
Yes
No
No
No
Activate Warning Condition
Yes
No
No
No
Activate Hard Shutdown Condition
Yes
No
No
No
Activate Warning Condition

Analog Input #3 Custom Parameter Low


Warning Event Audible Alert
Analog Input #3 Custom Parameter Low
Warning Event Breaker #1 Trip
Analog Input #3 Custom Parameter Low
Warning Event Breaker #2 Trip
Analog Input #3 Custom Parameter Low
Warning Event Fault Protection Timer
Analog Input #3 Custom Parameter Low
Shutdown Event Response Configuration
Analog Input #3 Custom Parameter Low
Shutdown Event Audible Alert
Analog Input #3 Custom Parameter Low
Shutdown Event Breaker #1 Trip
Analog Input #3 Custom Parameter Low
Shutdown Event Breaker #2 Trip
Analog Input #3 Custom Parameter Low
Shutdown Event Fault Protection Timer
Custom Event #1 Condition Exists Event
Response Configuration
Custom Event #1 Condition Exists Event
Audible Alert
Custom Event #1 Condition Exists Event
Breaker #1 Trip
Custom Event #1 Condition Exists Event
Breaker #2 Trip
Custom Event #1 Condition Exists Event
Fault Protection Timer
Custom Event #2 Condition Exists Event
Response Configuration
Custom Event #2 Condition Exists Event
Audible Alert
Custom Event #2 Condition Exists Event
Breaker #1 Trip
Custom Event #2 Condition Exists Event
Breaker #2 Trip
Custom Event #2 Condition Exists Event
Fault Protection Timer
Custom Event #3 Condition Exists Event
Response Configuration
Custom Event #3 Condition Exists Event
Audible Alert
Custom Event #3 Condition Exists Event
Breaker #1 Trip
Custom Event #3 Condition Exists Event
Breaker #2 Trip
Custom Event #3 Condition Exists Event
Fault Protection Timer
Custom Event #4 Condition Exists Event
Response Configuration
Custom Event #4 Condition Exists Event
Audible Alert
Custom Event #4 Condition Exists Event
Breaker #1 Trip

Yes
No
No
No
Activate Hard Shutdown Condition
Yes
No
No
No
Disable Condition
No
No
No
No
Activate Hard Shutdown Condition
No
No
No
No
Activate Soft Shutdown Condition
No
No
No
No
Disable Condition
No
No

Custom Event #4 Condition Exists Event


Breaker #2 Trip
Custom Event #4 Condition Exists Event
Fault Protection Timer
Custom Event #5 Condition Exists Event
Response Configuration
Custom Event #5 Condition Exists Event
Audible Alert
Custom Event #5 Condition Exists Event
Breaker #1 Trip
Custom Event #5 Condition Exists Event
Breaker #2 Trip
Custom Event #5 Condition Exists Event
Fault Protection Timer
Custom Event #6 Condition Exists Event
Response Configuration
Custom Event #6 Condition Exists Event
Audible Alert
Custom Event #6 Condition Exists Event
Breaker #1 Trip
Custom Event #6 Condition Exists Event
Breaker #2 Trip
Custom Event #6 Condition Exists Event
Fault Protection Timer
DIO #1 Custom Event # 1 Condition Exists
Event Response Configuration
DIO #1 Custom Event # 1 Condition Exists
Event Audible Alert
DIO #1 Custom Event # 1 Condition Exists
Event Breaker #1 Trip
DIO #1 Custom Event # 1 Condition Exists
Event Breaker #2 Trip
DIO #1 Custom Event # 1 Condition Exists
Event Fault Protection Timer
DIO #1 Custom Event # 2 Condition Exists
Event Response Configuration
DIO #1 Custom Event # 2 Condition Exists
Event Audible Alert
DIO #1 Custom Event # 2 Condition Exists
Event Breaker #1 Trip
DIO #1 Custom Event # 2 Condition Exists
Event Breaker #2 Trip
DIO #1 Custom Event # 2 Condition Exists
Event Fault Protection Timer
DIO #1 Custom Event # 3 Condition Exists
Event Response Configuration
DIO #1 Custom Event # 3 Condition Exists
Event Audible Alert
DIO #1 Custom Event # 3 Condition Exists
Event Breaker #1 Trip
DIO #1 Custom Event # 3 Condition Exists
Event Breaker #2 Trip
DIO #1 Custom Event # 3 Condition Exists
Event Fault Protection Timer

No
No
Disable Condition
No
No
No
No
Disable Condition
No
No
No
No
Disable Condition
No
No
No
No
Disable Condition
No
No
No
No
Disable Condition
No
No
No
No

DIO #1 Custom Event # 4 Condition Exists


Event Response Configuration
DIO #1 Custom Event # 4 Condition Exists
Event Audible Alert
DIO #1 Custom Event # 4 Condition Exists
Event Breaker #1 Trip
DIO #1 Custom Event # 4 Condition Exists
Event Breaker #2 Trip
DIO #1 Custom Event # 4 Condition Exists
Event Fault Protection Timer
DIO #1 Custom Event # 5 Condition Exists
Event Response Configuration
DIO #1 Custom Event # 5 Condition Exists
Event Audible Alert
DIO #1 Custom Event # 5 Condition Exists
Event Breaker #1 Trip
DIO #1 Custom Event # 5 Condition Exists
Event Breaker #2 Trip
DIO #1 Custom Event # 5 Condition Exists
Event Fault Protection Timer
DIO #1 Custom Event # 6 Condition Exists
Event Response Configuration
DIO #1 Custom Event # 6 Condition Exists
Event Audible Alert
DIO #1 Custom Event # 6 Condition Exists
Event Breaker #1 Trip
DIO #1 Custom Event # 6 Condition Exists
Event Breaker #2 Trip
DIO #1 Custom Event # 6 Condition Exists
Event Fault Protection Timer
DIO #1 Custom Event # 7 Condition Exists
Event Response Configuration
DIO #1 Custom Event # 7 Condition Exists
Event Audible Alert
DIO #1 Custom Event # 7 Condition Exists
Event Breaker #1 Trip
DIO #1 Custom Event # 7 Condition Exists
Event Breaker #2 Trip
DIO #1 Custom Event # 7 Condition Exists
Event Fault Protection Timer
DIO #1 Custom Event # 8 Condition Exists
Event Response Configuration
DIO #1 Custom Event # 8 Condition Exists
Event Audible Alert
DIO #1 Custom Event # 8 Condition Exists
Event Breaker #1 Trip
DIO #1 Custom Event # 8 Condition Exists
Event Breaker #2 Trip
DIO #1 Custom Event # 8 Condition Exists
Event Fault Protection Timer
DIO #1 Custom Event # 9 Condition Exists
Event Response Configuration
DIO #1 Custom Event # 9 Condition Exists
Event Audible Alert

Disable Condition
No
No
No
No
Disable Condition
No
No
No
No
Disable Condition
No
No
No
No
Activate Warning Condition
No
No
No
No
Activate Hard Shutdown Condition
No
No
Yes
No
Active Only Condition
No

DIO #1 Custom Event # 9 Condition Exists


Event Breaker #1 Trip
DIO #1 Custom Event # 9 Condition Exists
Event Breaker #2 Trip
DIO #1 Custom Event # 9 Condition Exists
Event Fault Protection Timer
DIO #1 Custom Event #10 Condition Exists
Event Response Configuration
DIO #1 Custom Event #10 Condition Exists
Event Audible Alert
DIO #1 Custom Event #10 Condition Exists
Event Breaker #1 Trip
DIO #1 Custom Event #10 Condition Exists
Event Breaker #2 Trip
DIO #1 Custom Event #10 Condition Exists
Event Fault Protection Timer
DIO #1 Custom Event #11 Condition Exists
Event Response Configuration
DIO #1 Custom Event #11 Condition Exists
Event Audible Alert
DIO #1 Custom Event #11 Condition Exists
Event Breaker #1 Trip
DIO #1 Custom Event #11 Condition Exists
Event Breaker #2 Trip
DIO #1 Custom Event #11 Condition Exists
Event Fault Protection Timer
DIO #1 Custom Event #12 Condition Exists
Event Response Configuration
DIO #1 Custom Event #12 Condition Exists
Event Audible Alert
DIO #1 Custom Event #12 Condition Exists
Event Breaker #1 Trip
DIO #1 Custom Event #12 Condition Exists
Event Breaker #2 Trip
DIO #1 Custom Event #12 Condition Exists
Event Fault Protection Timer
DIO #2 Custom Event # 1 Condition Exists
Event Response Configuration
DIO #2 Custom Event # 1 Condition Exists
Event Audible Alert
DIO #2 Custom Event # 1 Condition Exists
Event Breaker #1 Trip
DIO #2 Custom Event # 1 Condition Exists
Event Breaker #2 Trip
DIO #2 Custom Event # 1 Condition Exists
Event Fault Protection Timer
DIO #2 Custom Event # 2 Condition Exists
Event Response Configuration
DIO #2 Custom Event # 2 Condition Exists
Event Audible Alert
DIO #2 Custom Event # 2 Condition Exists
Event Breaker #1 Trip
DIO #2 Custom Event # 2 Condition Exists
Event Breaker #2 Trip

No
No
No
Active Only Condition
No
No
No
No
Disable Condition
No
No
No
No
Activate Warning Condition
No
No
No
No
Active Only Condition
No
No
No
No
Active Only Condition
No
No
No

DIO #2 Custom Event # 2 Condition Exists


Event Fault Protection Timer
DIO #2 Custom Event # 3 Condition Exists
Event Response Configuration
DIO #2 Custom Event # 3 Condition Exists
Event Audible Alert
DIO #2 Custom Event # 3 Condition Exists
Event Breaker #1 Trip
DIO #2 Custom Event # 3 Condition Exists
Event Breaker #2 Trip
DIO #2 Custom Event # 3 Condition Exists
Event Fault Protection Timer
DIO #2 Custom Event # 4 Condition Exists
Event Response Configuration
DIO #2 Custom Event # 4 Condition Exists
Event Audible Alert
DIO #2 Custom Event # 4 Condition Exists
Event Breaker #1 Trip
DIO #2 Custom Event # 4 Condition Exists
Event Breaker #2 Trip
DIO #2 Custom Event # 4 Condition Exists
Event Fault Protection Timer
DIO #2 Custom Event # 5 Condition Exists
Event Response Configuration
DIO #2 Custom Event # 5 Condition Exists
Event Audible Alert
DIO #2 Custom Event # 5 Condition Exists
Event Breaker #1 Trip
DIO #2 Custom Event # 5 Condition Exists
Event Breaker #2 Trip
DIO #2 Custom Event # 5 Condition Exists
Event Fault Protection Timer
DIO #2 Custom Event # 6 Condition Exists
Event Response Configuration
DIO #2 Custom Event # 6 Condition Exists
Event Audible Alert
DIO #2 Custom Event # 6 Condition Exists
Event Breaker #1 Trip
DIO #2 Custom Event # 6 Condition Exists
Event Breaker #2 Trip
DIO #2 Custom Event # 6 Condition Exists
Event Fault Protection Timer
DIO #2 Custom Event # 7 Condition Exists
Event Response Configuration
DIO #2 Custom Event # 7 Condition Exists
Event Audible Alert
DIO #2 Custom Event # 7 Condition Exists
Event Breaker #1 Trip
DIO #2 Custom Event # 7 Condition Exists
Event Breaker #2 Trip
DIO #2 Custom Event # 7 Condition Exists
Event Fault Protection Timer
DIO #2 Custom Event # 8 Condition Exists
Event Response Configuration

No
Active Only Condition
No
No
No
No
Active Only Condition
No
No
No
No
Active Only Condition
No
No
No
No
Active Only Condition
No
No
No
No
Active Only Condition
No
No
No
No
Active Only Condition

DIO #2 Custom Event # 8 Condition Exists


Event Audible Alert
DIO #2 Custom Event # 8 Condition Exists
Event Breaker #1 Trip
DIO #2 Custom Event # 8 Condition Exists
Event Breaker #2 Trip
DIO #2 Custom Event # 8 Condition Exists
Event Fault Protection Timer
DIO #2 Custom Event # 9 Condition Exists
Event Response Configuration
DIO #2 Custom Event # 9 Condition Exists
Event Audible Alert
DIO #2 Custom Event # 9 Condition Exists
Event Breaker #1 Trip
DIO #2 Custom Event # 9 Condition Exists
Event Breaker #2 Trip
DIO #2 Custom Event # 9 Condition Exists
Event Fault Protection Timer
DIO #2 Custom Event #10 Condition Exists
Event Response Configuration
DIO #2 Custom Event #10 Condition Exists
Event Audible Alert
DIO #2 Custom Event #10 Condition Exists
Event Breaker #1 Trip
DIO #2 Custom Event #10 Condition Exists
Event Breaker #2 Trip
DIO #2 Custom Event #10 Condition Exists
Event Fault Protection Timer
DIO #2 Custom Event #11 Condition Exists
Event Response Configuration
DIO #2 Custom Event #11 Condition Exists
Event Audible Alert
DIO #2 Custom Event #11 Condition Exists
Event Breaker #1 Trip
DIO #2 Custom Event #11 Condition Exists
Event Breaker #2 Trip
DIO #2 Custom Event #11 Condition Exists
Event Fault Protection Timer
DIO #2 Custom Event #12 Condition Exists
Event Response Configuration
DIO #2 Custom Event #12 Condition Exists
Event Audible Alert
DIO #2 Custom Event #12 Condition Exists
Event Breaker #1 Trip
DIO #2 Custom Event #12 Condition Exists
Event Breaker #2 Trip
DIO #2 Custom Event #12 Condition Exists
Event Fault Protection Timer
DIO #3 Custom Event # 1 Condition Exists
Event Response Configuration
DIO #3 Custom Event # 1 Condition Exists
Event Audible Alert
DIO #3 Custom Event # 1 Condition Exists
Event Breaker #1 Trip

No
No
No
No
Active Only Condition
No
No
No
No
Active Only Condition
No
No
No
No
Active Only Condition
No
No
No
No
Active Only Condition
No
No
No
No
Active Only Condition
No
No

DIO #3 Custom Event # 1 Condition Exists


Event Breaker #2 Trip
DIO #3 Custom Event # 1 Condition Exists
Event Fault Protection Timer
DIO #3 Custom Event # 2 Condition Exists
Event Response Configuration
DIO #3 Custom Event # 2 Condition Exists
Event Audible Alert
DIO #3 Custom Event # 2 Condition Exists
Event Breaker #1 Trip
DIO #3 Custom Event # 2 Condition Exists
Event Breaker #2 Trip
DIO #3 Custom Event # 2 Condition Exists
Event Fault Protection Timer
DIO #3 Custom Event # 3 Condition Exists
Event Response Configuration
DIO #3 Custom Event # 3 Condition Exists
Event Audible Alert
DIO #3 Custom Event # 3 Condition Exists
Event Breaker #1 Trip
DIO #3 Custom Event # 3 Condition Exists
Event Breaker #2 Trip
DIO #3 Custom Event # 3 Condition Exists
Event Fault Protection Timer
DIO #3 Custom Event # 4 Condition Exists
Event Response Configuration
DIO #3 Custom Event # 4 Condition Exists
Event Audible Alert
DIO #3 Custom Event # 4 Condition Exists
Event Breaker #1 Trip
DIO #3 Custom Event # 4 Condition Exists
Event Breaker #2 Trip
DIO #3 Custom Event # 4 Condition Exists
Event Fault Protection Timer
DIO #3 Custom Event # 5 Condition Exists
Event Response Configuration
DIO #3 Custom Event # 5 Condition Exists
Event Audible Alert
DIO #3 Custom Event # 5 Condition Exists
Event Breaker #1 Trip
DIO #3 Custom Event # 5 Condition Exists
Event Breaker #2 Trip
DIO #3 Custom Event # 5 Condition Exists
Event Fault Protection Timer
DIO #3 Custom Event # 6 Condition Exists
Event Response Configuration
DIO #3 Custom Event # 6 Condition Exists
Event Audible Alert
DIO #3 Custom Event # 6 Condition Exists
Event Breaker #1 Trip
DIO #3 Custom Event # 6 Condition Exists
Event Breaker #2 Trip
DIO #3 Custom Event # 6 Condition Exists
Event Fault Protection Timer

No
No
Active Only Condition
No
No
No
No
Active Only Condition
No
No
No
No
Active Only Condition
No
No
No
No
Active Only Condition
No
No
No
No
Active Only Condition
No
No
No
No

DIO #3 Custom Event # 7 Condition Exists


Event Response Configuration
DIO #3 Custom Event # 7 Condition Exists
Event Audible Alert
DIO #3 Custom Event # 7 Condition Exists
Event Breaker #1 Trip
DIO #3 Custom Event # 7 Condition Exists
Event Breaker #2 Trip
DIO #3 Custom Event # 7 Condition Exists
Event Fault Protection Timer
DIO #3 Custom Event # 8 Condition Exists
Event Response Configuration
DIO #3 Custom Event # 8 Condition Exists
Event Audible Alert
DIO #3 Custom Event # 8 Condition Exists
Event Breaker #1 Trip
DIO #3 Custom Event # 8 Condition Exists
Event Breaker #2 Trip
DIO #3 Custom Event # 8 Condition Exists
Event Fault Protection Timer
DIO #3 Custom Event # 9 Condition Exists
Event Response Configuration
DIO #3 Custom Event # 9 Condition Exists
Event Audible Alert
DIO #3 Custom Event # 9 Condition Exists
Event Breaker #1 Trip
DIO #3 Custom Event # 9 Condition Exists
Event Breaker #2 Trip
DIO #3 Custom Event # 9 Condition Exists
Event Fault Protection Timer
DIO #3 Custom Event #10 Condition Exists
Event Response Configuration
DIO #3 Custom Event #10 Condition Exists
Event Audible Alert
DIO #3 Custom Event #10 Condition Exists
Event Breaker #1 Trip
DIO #3 Custom Event #10 Condition Exists
Event Breaker #2 Trip
DIO #3 Custom Event #10 Condition Exists
Event Fault Protection Timer
DIO #3 Custom Event #11 Condition Exists
Event Response Configuration
DIO #3 Custom Event #11 Condition Exists
Event Audible Alert
DIO #3 Custom Event #11 Condition Exists
Event Breaker #1 Trip
DIO #3 Custom Event #11 Condition Exists
Event Breaker #2 Trip
DIO #3 Custom Event #11 Condition Exists
Event Fault Protection Timer
DIO #3 Custom Event #12 Condition Exists
Event Response Configuration
DIO #3 Custom Event #12 Condition Exists
Event Audible Alert

Active Only Condition


No
No
No
No
Active Only Condition
No
No
No
No
Active Only Condition
No
No
No
No
Active Only Condition
No
No
No
No
Active Only Condition
No
No
No
No
Active Only Condition
No

DIO #3 Custom Event #12 Condition Exists


Event Breaker #1 Trip
DIO #3 Custom Event #12 Condition Exists
Event Breaker #2 Trip
DIO #3 Custom Event #12 Condition Exists
Event Fault Protection Timer
Fuel Fill/Drain Feature Enable Status
Fuel Fill Activation Tank Level Percentage
Threshold
Fuel Fill Deactivation Tank Level
Percentage Threshold
Fuel Drain Deactivation Tank Level
Percentage Threshold
Generator Connection Configuration
Generator Potential Transformer Primary
Winding Rating
Generator Potential Transformer
Secondary Winding Rating
Generator Current Transformer Primary
Winding Rating
Generator Current Transformer Secondary
Winding Rating
Number of Generator Poles
Generator Rated Frequency
Generator Rated Voltage
Generator Rated Power
Generator Rated Apparent Power
Generator Rated Frequency #1
Generator Rated Voltage #1
Generator Rated Power #1
Generator Rated Apparent Power #1
Generator Rated Frequency #2
Generator Rated Voltage #2
Generator Rated Power #2
Generator Rated Apparent Power #2
Generator Rated Frequency #3
Generator Rated Voltage #3
Generator Rated Power #3
Generator Rated Apparent Power #3
Generator Rated Frequency #4
Generator Rated Voltage #4
Generator Rated Power #4
Generator Rated Apparent Power #4
Maximum Generator Voltage Output Bias
Percentage
Customer Password Security Level to
Reset Generator Energy Meters
Generator Definite Time Overcurrent
Warning Event Percentage Threshold
Generator Inverse Time Overcurrent
Shutdown Event Time Multiplier

No
No
No
Disabled
5.0

5.0

5.0

Wye (or Star) Connection


1

Volts

Volts

3000

Amps

Amps

4
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
60.00
480
1825
2282
45.00
100
2
1
50.00
400
1600
2000
45.00
100
4
1
15

Poles
Volts
kW
kVA
Hz
Volts
kW
kVA
Hz
Volts
kW
kVA
Hz
Volts
kW
kVA
Hz
Volts
kW
kVA
%

3-Factory, Single Use


105

10.00

sec

Generator Definite Time Overcurrent


Shutdown Event Percentage Threshold
Generator Definite Time Overcurrent
Shutdown Event Notification Delay Time
Generator Over Frequency Warning Event
Percentage Threshold
Generator Over Frequency Warning Event
Notification Delay Time
Generator Over Frequency Shutdown
Event Percentage Threshold
Generator Over Frequency Shutdown
Event Notification Delay Time
Generator Under Frequency Warning
Event Percentage Threshold
Generator Under Frequency Warning
Event Notification Delay Time
Generator Under Frequency Shutdown
Event Percentage Threshold
Generator Under Frequency Shutdown
Event Notification Delay Time
Generator Over Voltage Warning Event
Percentage Threshold
Generator Over Voltage Warning Event
Notification Delay Time
Generator Over Voltage Shutdown Event
Percentage Threshold
Generator Over Voltage Shutdown Event
Notification Delay Time
Generator Under Voltage Warning Event
Percentage Threshold
Generator Under Voltage Warning Event
Notification Delay Time
Generator Under Voltage Shutdown Event
Percentage Threshold
Generator Under Voltage Shutdown Event
Notification Delay Time
Generator Reverse Power Warning Event
Percentage Threshold
Generator Reverse Power Warning Event
Notification Delay Time
Generator Reverse Power Shutdown Event
Percentage Threshold
Generator Reverse Power Shutdown Event
Notification Delay Time
Generator Reverse Reactive Power
Warning Event Percentage Threshold
Generator Reverse Reactive Power
Warning Event Notification Delay Time
Generator Reverse Reactive Power
Shutdown Event Percentage Threshold
Generator Reverse Reactive Power
Shutdown Event Notification Delay Time
Programmable Cycle Timer #1 Activation
Day - Sunday

110

10.0

sec

105.0

10

sec

110.0

10

sec

95.0

10

sec

90.0

10

sec

108

10

sec

111

10

sec

92

10

sec

89

10

sec

10

10

sec

15

10

sec

5.00

sec

15.00

10

sec

Deactivate

Programmable Cycle Timer #1 Activation


Day - Monday
Programmable Cycle Timer #1 Activation
Day - Tuesday
Programmable Cycle Timer #1 Activation
Day - Wednesday
Programmable Cycle Timer #1 Activation
Day - Thursday
Programmable Cycle Timer #1 Activation
Day - Friday
Programmable Cycle Timer #1 Activation
Day - Saturday
Programmable Cycle Timer #1 Activation
Start Time
Programmable Cycle Timer #1 Active Time
Programmable Cycle Timer #1 Output #1
Activation Configuration
Programmable Cycle Timer #1 Output #2
Activation Configuration
Programmable Cycle Timer #2 Activation
Day - Sunday
Programmable Cycle Timer #2 Activation
Day - Monday
Programmable Cycle Timer #2 Activation
Day - Tuesday
Programmable Cycle Timer #2 Activation
Day - Wednesday
Programmable Cycle Timer #2 Activation
Day - Thursday
Programmable Cycle Timer #2 Activation
Day - Friday
Programmable Cycle Timer #2 Activation
Day - Saturday
Programmable Cycle Timer #2 Activation
Start Time
Programmable Cycle Timer #2 Active Time
Programmable Cycle Timer #2 Output #1
Activation Configuration
Programmable Cycle Timer #2 Output #2
Activation Configuration
Programmable Cycle Timer #3 Activation
Day - Sunday
Programmable Cycle Timer #3 Activation
Day - Monday
Programmable Cycle Timer #3 Activation
Day - Tuesday
Programmable Cycle Timer #3 Activation
Day - Wednesday
Programmable Cycle Timer #3 Activation
Day - Thursday
Programmable Cycle Timer #3 Activation
Day - Friday
Programmable Cycle Timer #3 Activation
Day - Saturday

Deactivate
Deactivate
Deactivate
Deactivate
Deactivate
Deactivate
0

min

1
Inactive

min

Inactive
Deactivate
Deactivate
Deactivate
Deactivate
Deactivate
Deactivate
Deactivate
0

min

1
Inactive

min

Inactive
Deactivate
Deactivate
Deactivate
Deactivate
Deactivate
Deactivate
Deactivate

Programmable Cycle Timer #3 Activation


Start Time
Programmable Cycle Timer #3 Active Time
Programmable Cycle Timer #3 Output #1
Activation Configuration
Programmable Cycle Timer #3 Output #2
Activation Configuration
Programmable Cycle Timer #4 Activation
Day - Sunday
Programmable Cycle Timer #4 Activation
Day - Monday
Programmable Cycle Timer #4 Activation
Day - Tuesday
Programmable Cycle Timer #4 Activation
Day - Wednesday
Programmable Cycle Timer #4 Activation
Day - Thursday
Programmable Cycle Timer #4 Activation
Day - Friday
Programmable Cycle Timer #4 Activation
Day - Saturday
Programmable Cycle Timer #4 Activation
Start Time
Programmable Cycle Timer #4 Active Time
Programmable Cycle Timer #4 Output #1
Activation Configuration
Programmable Cycle Timer #4 Output #2
Activation Configuration
Programmable Cycle Timer #5 Activation
Day - Sunday
Programmable Cycle Timer #5 Activation
Day - Monday
Programmable Cycle Timer #5 Activation
Day - Tuesday
Programmable Cycle Timer #5 Activation
Day - Wednesday
Programmable Cycle Timer #5 Activation
Day - Thursday
Programmable Cycle Timer #5 Activation
Day - Friday
Programmable Cycle Timer #5 Activation
Day - Saturday
Programmable Cycle Timer #5 Activation
Start Time
Programmable Cycle Timer #5 Active Time
Programmable Cycle Timer #5 Output #1
Activation Configuration
Programmable Cycle Timer #5 Output #2
Activation Configuration
Programmable Cycle Timer #6 Activation
Day - Sunday
Programmable Cycle Timer #6 Activation
Day - Monday

min

1
Inactive

min

Inactive
Deactivate
Deactivate
Deactivate
Deactivate
Deactivate
Deactivate
Deactivate
0

min

1
Inactive

min

Inactive
Deactivate
Deactivate
Deactivate
Deactivate
Deactivate
Deactivate
Deactivate
0

min

1
Inactive

min

Inactive
Deactivate
Deactivate

Programmable Cycle Timer #6 Activation


Day - Tuesday
Programmable Cycle Timer #6 Activation
Day - Wednesday
Programmable Cycle Timer #6 Activation
Day - Thursday
Programmable Cycle Timer #6 Activation
Day - Friday
Programmable Cycle Timer #6 Activation
Day - Saturday
Programmable Cycle Timer #6 Activation
Start Time
Programmable Cycle Timer #6 Active Time
Programmable Cycle Timer #6 Output #1
Activation Configuration
Programmable Cycle Timer #6 Output #2
Activation Configuration
Programmable Cycle Timer #7 Activation
Day - Sunday
Programmable Cycle Timer #7 Activation
Day - Monday
Programmable Cycle Timer #7 Activation
Day - Tuesday
Programmable Cycle Timer #7 Activation
Day - Wednesday
Programmable Cycle Timer #7 Activation
Day - Thursday
Programmable Cycle Timer #7 Activation
Day - Friday
Programmable Cycle Timer #7 Activation
Day - Saturday
Programmable Cycle Timer #7 Activation
Start Time
Programmable Cycle Timer #7 Active Time
Programmable Cycle Timer #7 Output #1
Activation Configuration
Programmable Cycle Timer #7 Output #2
Activation Configuration
Electronic Control Module Reduced Power
Mode Enable Status
Electronic Control Module Reduced Power
Mode Delay Time
Relay Output #1 Usage Type
Relay Output #1 Command/Status
Parameter Data Identification
Relay Output #1 Event Suspect Parameter
Number
Relay Output #1 Event Trigger Condition
Relay Output #2 Usage Type
Relay Output #2 Command/Status
Parameter Data Identification
Relay Output #2 Event Suspect Parameter
Number
Relay Output #2 Event Trigger Condition

Deactivate
Deactivate
Deactivate
Deactivate
Deactivate
0

min

1
Inactive

min

Inactive
Deactivate
Deactivate
Deactivate
Deactivate
Deactivate
Deactivate
Deactivate
0

min

1
Inactive

min

Inactive
Disabled
30
Command/Status Parameter
Starter Motor Relay
Disabled or Not Installed
Disabled or Not Installed
Command/Status Parameter
Fuel Control Relay
Disabled or Not Installed
Disabled or Not Installed

min

Relay Output #3 Usage Type


Relay Output #3 Command/Status
Parameter Data Identification
Relay Output #3 Event Suspect Parameter
Number
Relay Output #3 Event Trigger Condition
Relay Output #4 Usage Type
Relay Output #4 Command/Status
Parameter Data Identification
Relay Output #4 Event Suspect Parameter
Number
Relay Output #4 Event Trigger Condition
Relay Output #5 Usage Type
Relay Output #5 Command/Status
Parameter Data Identification
Relay Output #5 Event Suspect Parameter
Number
Relay Output #5 Event Trigger Condition
Relay Output #6 Usage Type
Relay Output #6 Command/Status
Parameter Data Identification
Relay Output #6 Event Suspect Parameter
Number
Relay Output #6 Event Trigger Condition
Relay Output #7 Usage Type
Relay Output #7 Command/Status
Parameter Data Identification
Relay Output #7 Event Suspect Parameter
Number
Relay Output #7 Event Trigger Condition
Relay Output #8 Usage Type
Relay Output #8 Command/Status
Parameter Data Identification
Relay Output #8 Event Suspect Parameter
Number
Relay Output #8 Event Trigger Condition
Maintenance Level 1 Cycle Interval Hours
Maintenance Level 1 Cycle Interval Days
Customer Password Security Level to
Reset Service Maintenance Interval
Programmable Trip Point Function #1
Trigger Condition
Programmable Trip Point Function #1
Percentage Threshold
Programmable Trip Point Function #1
Hysteresis Percentage
Programmable Trip Point Function #1 Trip
Activation Delay Time
Programmable Trip Point Function #1 Trip
Deactivation Delay Time
Programmable Trip Point Function #2
Trigger Condition

Command/Status Parameter
Common Alarm
Disabled or Not Installed
Disabled or Not Installed
Command/Status Parameter
Common Shutdown
Disabled or Not Installed
Disabled or Not Installed
Command/Status Parameter
Engine Started
Disabled or Not Installed
Disabled or Not Installed
Command/Status Parameter
Rated Speed
Disabled or Not Installed
Disabled or Not Installed
Command/Status Parameter
Auto Mode
Disabled or Not Installed
Disabled or Not Installed
Disabled
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
500
180
1-Operator

hours

Disabled
90

10

sec

sec

Trip Below Threshold

Programmable Trip Point Function #2


Percentage Threshold
Programmable Trip Point Function #2
Hysteresis Percentage
Programmable Trip Point Function #2 Trip
Activation Delay Time
Programmable Trip Point Function #2 Trip
Deactivation Delay Time
DIO #1 Event Input Function # 1
Notification Delay Time
DIO #1 Event Input Function # 1 Failure
Mode Identifier
DIO #1 Event Input Function # 1 Suspect
Parameter Number
DIO #1 Event Input Function # 2
Notification Delay Time
DIO #1 Event Input Function # 2 Failure
Mode Identifier
DIO #1 Event Input Function # 2 Suspect
Parameter Number
DIO #1 Event Input Function # 3
Notification Delay Time
DIO #1 Event Input Function # 3 Failure
Mode Identifier
DIO #1 Event Input Function # 3 Suspect
Parameter Number
DIO #1 Event Input Function # 4
Notification Delay Time
DIO #1 Event Input Function # 4 Failure
Mode Identifier
DIO #1 Event Input Function # 4 Suspect
Parameter Number
DIO #1 Event Input Function # 5
Notification Delay Time
DIO #1 Event Input Function # 5 Failure
Mode Identifier
DIO #1 Event Input Function # 5 Suspect
Parameter Number
DIO #1 Event Input Function # 6
Notification Delay Time
DIO #1 Event Input Function # 6 Failure
Mode Identifier
DIO #1 Event Input Function # 6 Suspect
Parameter Number
DIO #1 Event Input Function # 7
Notification Delay Time
DIO #1 Event Input Function # 7 Failure
Mode Identifier
DIO #1 Event Input Function # 7 Suspect
Parameter Number
DIO #1 Event Input Function # 8
Notification Delay Time
DIO #1 Event Input Function # 8 Failure
Mode Identifier

51

33

sec

sec

Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed

sec

DIO #1 Event Input Function # 8 Suspect


Parameter Number
DIO #1 Event Input Function # 9
Notification Delay Time
DIO #1 Event Input Function # 9 Failure
Mode Identifier
DIO #1 Event Input Function # 9 Suspect
Parameter Number
DIO #1 Event Input Function #10
Notification Delay Time
DIO #1 Event Input Function #10 Failure
Mode Identifier
DIO #1 Event Input Function #10 Suspect
Parameter Number
DIO #1 Event Input Function #11
Notification Delay Time
DIO #1 Event Input Function #11 Failure
Mode Identifier
DIO #1 Event Input Function #11 Suspect
Parameter Number
DIO #1 Event Input Function #12
Notification Delay Time
DIO #1 Event Input Function #12 Failure
Mode Identifier
DIO #1 Event Input Function #12 Suspect
Parameter Number
DIO #2 Event Input Function # 1
Notification Delay Time
DIO #2 Event Input Function # 1 Failure
Mode Identifier
DIO #2 Event Input Function # 1 Suspect
Parameter Number
DIO #2 Event Input Function # 2
Notification Delay Time
DIO #2 Event Input Function # 2 Failure
Mode Identifier
DIO #2 Event Input Function # 2 Suspect
Parameter Number
DIO #2 Event Input Function # 3
Notification Delay Time
DIO #2 Event Input Function # 3 Failure
Mode Identifier
DIO #2 Event Input Function # 3 Suspect
Parameter Number
DIO #2 Event Input Function # 4
Notification Delay Time
DIO #2 Event Input Function # 4 Failure
Mode Identifier
DIO #2 Event Input Function # 4 Suspect
Parameter Number
DIO #2 Event Input Function # 5
Notification Delay Time
DIO #2 Event Input Function # 5 Failure
Mode Identifier

Disabled or Not Installed


Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed

sec

DIO #2 Event Input Function # 5 Suspect


Parameter Number
DIO #2 Event Input Function # 6
Notification Delay Time
DIO #2 Event Input Function # 6 Failure
Mode Identifier
DIO #2 Event Input Function # 6 Suspect
Parameter Number
DIO #2 Event Input Function # 7
Notification Delay Time
DIO #2 Event Input Function # 7 Failure
Mode Identifier
DIO #2 Event Input Function # 7 Suspect
Parameter Number
DIO #2 Event Input Function # 8
Notification Delay Time
DIO #2 Event Input Function # 8 Failure
Mode Identifier
DIO #2 Event Input Function # 8 Suspect
Parameter Number
DIO #2 Event Input Function # 9
Notification Delay Time
DIO #2 Event Input Function # 9 Failure
Mode Identifier
DIO #2 Event Input Function # 9 Suspect
Parameter Number
DIO #2 Event Input Function #10
Notification Delay Time
DIO #2 Event Input Function #10 Failure
Mode Identifier
DIO #2 Event Input Function #10 Suspect
Parameter Number
DIO #2 Event Input Function #11
Notification Delay Time
DIO #2 Event Input Function #11 Failure
Mode Identifier
DIO #2 Event Input Function #11 Suspect
Parameter Number
DIO #2 Event Input Function #12
Notification Delay Time
DIO #2 Event Input Function #12 Failure
Mode Identifier
DIO #2 Event Input Function #12 Suspect
Parameter Number
DIO #3 Event Input Function # 1
Notification Delay Time
DIO #3 Event Input Function # 1 Failure
Mode Identifier
DIO #3 Event Input Function # 1 Suspect
Parameter Number
DIO #3 Event Input Function # 2
Notification Delay Time
DIO #3 Event Input Function # 2 Failure
Mode Identifier

Disabled or Not Installed


Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed

sec

DIO #3 Event Input Function # 2 Suspect


Parameter Number
DIO #3 Event Input Function # 3
Notification Delay Time
DIO #3 Event Input Function # 3 Failure
Mode Identifier
DIO #3 Event Input Function # 3 Suspect
Parameter Number
DIO #3 Event Input Function # 4
Notification Delay Time
DIO #3 Event Input Function # 4 Failure
Mode Identifier
DIO #3 Event Input Function # 4 Suspect
Parameter Number
DIO #3 Event Input Function # 5
Notification Delay Time
DIO #3 Event Input Function # 5 Failure
Mode Identifier
DIO #3 Event Input Function # 5 Suspect
Parameter Number
DIO #3 Event Input Function # 6
Notification Delay Time
DIO #3 Event Input Function # 6 Failure
Mode Identifier
DIO #3 Event Input Function # 6 Suspect
Parameter Number
DIO #3 Event Input Function # 7
Notification Delay Time
DIO #3 Event Input Function # 7 Failure
Mode Identifier
DIO #3 Event Input Function # 7 Suspect
Parameter Number
DIO #3 Event Input Function # 8
Notification Delay Time
DIO #3 Event Input Function # 8 Failure
Mode Identifier
DIO #3 Event Input Function # 8 Suspect
Parameter Number
DIO #3 Event Input Function # 9
Notification Delay Time
DIO #3 Event Input Function # 9 Failure
Mode Identifier
DIO #3 Event Input Function # 9 Suspect
Parameter Number
DIO #3 Event Input Function #10
Notification Delay Time
DIO #3 Event Input Function #10 Failure
Mode Identifier
DIO #3 Event Input Function #10 Suspect
Parameter Number
DIO #3 Event Input Function #11
Notification Delay Time
DIO #3 Event Input Function #11 Failure
Mode Identifier

Disabled or Not Installed


Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed

sec

DIO #3 Event Input Function #11 Suspect


Parameter Number
DIO #3 Event Input Function #12
Notification Delay Time
DIO #3 Event Input Function #12 Failure
Mode Identifier
DIO #3 Event Input Function #12 Suspect
Parameter Number
DIO #4 Event Input Function # 1
Notification Delay Time
DIO #4 Event Input Function # 1 Failure
Mode Identifier
DIO #4 Event Input Function # 1 Suspect
Parameter Number
DIO #4 Event Input Function # 2
Notification Delay Time
DIO #4 Event Input Function # 2 Failure
Mode Identifier
DIO #4 Event Input Function # 2 Suspect
Parameter Number
DIO #4 Event Input Function # 3
Notification Delay Time
DIO #4 Event Input Function # 3 Failure
Mode Identifier
DIO #4 Event Input Function # 3 Suspect
Parameter Number
DIO #4 Event Input Function # 4
Notification Delay Time
DIO #4 Event Input Function # 4 Failure
Mode Identifier
DIO #4 Event Input Function # 4 Suspect
Parameter Number
DIO #4 Event Input Function # 5
Notification Delay Time
DIO #4 Event Input Function # 5 Failure
Mode Identifier
DIO #4 Event Input Function # 5 Suspect
Parameter Number
DIO #4 Event Input Function # 6
Notification Delay Time
DIO #4 Event Input Function # 6 Failure
Mode Identifier
DIO #4 Event Input Function # 6 Suspect
Parameter Number
DIO #4 Event Input Function # 7
Notification Delay Time
DIO #4 Event Input Function # 7 Failure
Mode Identifier
DIO #4 Event Input Function # 7 Suspect
Parameter Number
DIO #4 Event Input Function # 8
Notification Delay Time
DIO #4 Event Input Function # 8 Failure
Mode Identifier

Disabled or Not Installed


Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed

sec

DIO #4 Event Input Function # 8 Suspect


Parameter Number
DIO #4 Event Input Function # 9
Notification Delay Time
DIO #4 Event Input Function # 9 Failure
Mode Identifier
DIO #4 Event Input Function # 9 Suspect
Parameter Number
DIO #4 Event Input Function #10
Notification Delay Time
DIO #4 Event Input Function #10 Failure
Mode Identifier
DIO #4 Event Input Function #10 Suspect
Parameter Number
DIO #4 Event Input Function #11
Notification Delay Time
DIO #4 Event Input Function #11 Failure
Mode Identifier
DIO #4 Event Input Function #11 Suspect
Parameter Number
DIO #4 Event Input Function #12
Notification Delay Time
DIO #4 Event Input Function #12 Failure
Mode Identifier
DIO #4 Event Input Function #12 Suspect
Parameter Number
DIO #1 Event Output Function # 1 Suspect
Parameter Number
DIO #1 Event Output Function # 1 Trigger
Condition
DIO #1 Event Output Function # 2 Suspect
Parameter Number
DIO #1 Event Output Function # 2 Trigger
Condition
DIO #1 Event Output Function # 3 Suspect
Parameter Number
DIO #1 Event Output Function # 3 Trigger
Condition
DIO #1 Event Output Function # 4 Suspect
Parameter Number
DIO #1 Event Output Function # 4 Trigger
Condition
DIO #1 Event Output Function # 5 Suspect
Parameter Number
DIO #1 Event Output Function # 5 Trigger
Condition
DIO #1 Event Output Function # 6 Suspect
Parameter Number
DIO #1 Event Output Function # 6 Trigger
Condition
DIO #1 Event Output Function # 7 Suspect
Parameter Number
DIO #1 Event Output Function # 7 Trigger
Condition

Disabled or Not Installed


Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed

sec

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed

sec

DIO #1 Event Output Function # 8 Suspect


Parameter Number
DIO #1 Event Output Function # 8 Trigger
Condition
DIO #2 Event Output Function # 1 Suspect
Parameter Number
DIO #2 Event Output Function # 1 Trigger
Condition
DIO #2 Event Output Function # 2 Suspect
Parameter Number
DIO #2 Event Output Function # 2 Trigger
Condition
DIO #2 Event Output Function # 3 Suspect
Parameter Number
DIO #2 Event Output Function # 3 Trigger
Condition
DIO #2 Event Output Function # 4 Suspect
Parameter Number
DIO #2 Event Output Function # 4 Trigger
Condition
DIO #2 Event Output Function # 5 Suspect
Parameter Number
DIO #2 Event Output Function # 5 Trigger
Condition
DIO #2 Event Output Function # 6 Suspect
Parameter Number
DIO #2 Event Output Function # 6 Trigger
Condition
DIO #2 Event Output Function # 7 Suspect
Parameter Number
DIO #2 Event Output Function # 7 Trigger
Condition
DIO #2 Event Output Function # 8 Suspect
Parameter Number
DIO #2 Event Output Function # 8 Trigger
Condition
DIO #3 Event Output Function # 1 Suspect
Parameter Number
DIO #3 Event Output Function # 1 Trigger
Condition
DIO #3 Event Output Function # 2 Suspect
Parameter Number
DIO #3 Event Output Function # 2 Trigger
Condition
DIO #3 Event Output Function # 3 Suspect
Parameter Number
DIO #3 Event Output Function # 3 Trigger
Condition
DIO #3 Event Output Function # 4 Suspect
Parameter Number
DIO #3 Event Output Function # 4 Trigger
Condition
DIO #3 Event Output Function # 5 Suspect
Parameter Number

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed

DIO #3 Event Output Function # 5 Trigger


Condition
DIO #3 Event Output Function # 6 Suspect
Parameter Number
DIO #3 Event Output Function # 6 Trigger
Condition
DIO #3 Event Output Function # 7 Suspect
Parameter Number
DIO #3 Event Output Function # 7 Trigger
Condition
DIO #3 Event Output Function # 8 Suspect
Parameter Number
DIO #3 Event Output Function # 8 Trigger
Condition
DIO #4 Event Output Function # 1 Suspect
Parameter Number
DIO #4 Event Output Function # 1 Trigger
Condition
DIO #4 Event Output Function # 2 Suspect
Parameter Number
DIO #4 Event Output Function # 2 Trigger
Condition
DIO #4 Event Output Function # 3 Suspect
Parameter Number
DIO #4 Event Output Function # 3 Trigger
Condition
DIO #4 Event Output Function # 4 Suspect
Parameter Number
DIO #4 Event Output Function # 4 Trigger
Condition
DIO #4 Event Output Function # 5 Suspect
Parameter Number
DIO #4 Event Output Function # 5 Trigger
Condition
DIO #4 Event Output Function # 6 Suspect
Parameter Number
DIO #4 Event Output Function # 6 Trigger
Condition
DIO #4 Event Output Function # 7 Suspect
Parameter Number
DIO #4 Event Output Function # 7 Trigger
Condition
DIO #4 Event Output Function # 8 Suspect
Parameter Number
DIO #4 Event Output Function # 8 Trigger
Condition
Engine Serial Number
Display Pressure Units Configuration
Display Temperature Units Configuration
Display Volume Units Configuration

Disabled or Not Installed


Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
Not Programmed
psi
Degrees Centigrade (Celsius)
US gallons

3516B Engine - Genset #1 (1HZ03948)


Parameter
Equipment ID

Value
NBR00416

Engine Serial Number


ECM Serial Number
Personality Module Part Number
Personality Module Release Date
Personality Module Description

1HZ03948
0272B082JP
3985119-00
SEP12
GENSET

Logged Diagnostic Codes [Diagnostic Clock = 4973.7540 hours] - 3516B Engine - Genset #1
(1HZ03948)
Code
91- 8
168- 1
110- 3

Description
Throttle Position Sensor : Abnormal Frequency,
Pulse Width, or Period
Electrical System Voltage : Low
Engine Coolant Temperature Sensor : Voltage
Above Normal

Occ.
20

First
4951

Last
4973

1
1

4973
4951

4973
4951

Logged Event Codes [Diagnostic Clock = 4973.7540 hours] - 3516B Engine - Genset #1
(1HZ03948)
Code
E095 (1)
E198 (3)
E264 (3)

Description
Fuel Filter Restriction Warning
Low Fuel Pressure
Emergency Stop Activated

Occ.
6
2
6

First
4936
4928
4962

Last
4971
4951
4973

Active Diagnostic Codes - 3516B Engine - Genset #1 (1HZ03948)


Code
No Active
Codes

Description

Active Event Codes - 3516B Engine - Genset #1 (1HZ03948)


Code
No Active
Events

Description

Current Totals - 3516B Engine - Genset #1 (1HZ03948)


Description
Total Time
Total Fuel

Value
4973
413869

Unit
hours
gal

Configuration - 3516B Engine - Genset #1 (1HZ03948)


Description
Equipment ID
Engine Serial Number
ECM Serial Number
Personality Module Part Number
Personality Module Release Date
Rated Engine Speed
Fuel Ratio Control Offset
Acceleration Delay Time
Engine Acceleration Rate
Low Idle Speed

Value
NBR00416
1HZ03948
0272B082JP
3985119-00
SEP12
1500
0
0
250
900

Unit

rpm
sec
rpm/s
rpm

Cooldown Speed
Cooldown Duration
Engine Pre-Lube Duration
Engine Pre-Lube System Configuration
Engine Continuous Pre-Lube Interval
Crank Duration
Maximum Number of Crank Cycles
Crank Terminate RPM
Engine Speed Droop
Rated Fuel Position
Fuel Correction Factor
Governor Gain Factor #1
Governor Minimum Stability Factor #1
Governor Maximum Stability Factor #1
FLS
FTS
Air Shutoff
Air Intake Shutoff Detection Installation
Status
Ether Control
Engine Cooling System Config
Cold Cylinder Cutout
Direct Fuel Control Mode
Desired Speed Input Configuration
Throttle Air Pressure Sensor Installation
Status
Throttle Input Low Idle Duty Cycle Setpoint
Throttle Input High Idle Duty Cycle Setpoint
Secondary Desired Speed Input
Configuration
Fuel Enable Input Configuration
Secondary Fuel Enable Input Enable
Status
Coolant Level Sensor
Aftercooler Coolant Level Sensor
Installation Status
Cat Data Link #2 Identifier
Inlet Air Temperature Sensor
Engine Oil Temperature Sensor Installation
Status
Total Tattletale

1500
0
0
Automatic
0
0
0
400
0.0
24.700
0
26214
629
7864
0
0
Disabled
Unavailable

rpm
min
sec
min
sec
rpm
%
mm
%

Disabled
SCAC (Separate Circuit Aftercooled)
Disabled
Disabled
PWM
Unavailable
Unavailable
Unavailable
CAN Input

%
%

CAN Input
Disabled
Not Installed
Not Installed
Engine Control #1
Not Installed
Installed
15

Lifetime: Time vs Engine Speed - 3516B Engine - Genset #1 (1HZ03948)


Engine Speed( rpm )
<400
400-499
500-599
600-699
700-799

hours
1.90
0.45
0.40
0.35
0.35

%
0.04
0.01
0.01
0.01
0.01

800-899
900-999
1000-1099
1100-1199
1200-1299
1300-1399
1400-1499
1500-1599
1600-1699
1700-1799
1800-1899
1900-1999
>2000

0.85
0.75
0.25
0.40
0.35
0.20
969.40
4006.30
0.05
0.95
1.85
0.00
0.00

0.02
0.02
0.01
0.01
0.01
0.00
19.45
80.37
0.00
0.02
0.04
0.00
0.00

Lifetime: Time vs Engine Load Factor - 3516B Engine - Genset #1 (1HZ03948)


Engine Load Factor( % )
<5
5-9
10-14
15-19
20-24
25-29
30-34
35-39
40-44
45-49
50-54
55-59
60-64
65-69
70-74
75-79
80-84
85-89
90-94
95-99
>100

hours
5.05
0.60
0.10
0.20
28.35
12.60
5.25
4.30
3.65
4.70
5.80
6.05
9.30
20.25
241.60
2308.15
956.25
22.75
411.40
914.40
24.05

%
0.10
0.01
0.00
0.00
0.57
0.25
0.11
0.09
0.07
0.09
0.12
0.12
0.19
0.41
4.85
46.30
19.18
0.46
8.25
18.34
0.48

Lifetime: Time vs Right Exhaust Temperature - 3516B Engine - Genset #1 (1HZ03948)


Right Exhaust Temperature(
Deg F )
<842
842-868
869-895
896-922
923-949
950-976
977-1003

hours

62.20
2.15
2.95
4.00
5.70
8.15
10.60

1.25
0.04
0.06
0.08
0.11
0.16
0.21

1004-1030
1031-1057
1058-1084
1085-1111
1112-1138
1139-1165
1166-1192
1193-1219
1220-1246
1247-1273
1274-1300
1301-1327
1328-1354
1355-1381
1382-1408
>1409

27.30
544.90
2157.60
1772.05
374.70
11.05
1.05
0.45
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

0.55
10.93
43.28
35.55
7.52
0.22
0.02
0.01
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

Lifetime: Time vs Left Exhaust Temperature - 3516B Engine - Genset #1 (1HZ03948)


Left Exhaust Temperature( Deg
F)
<842
842-868
869-895
896-922
923-949
950-976
977-1003
1004-1030
1031-1057
1058-1084
1085-1111
1112-1138
1139-1165
1166-1192
1193-1219
1220-1246
1247-1273
1274-1300
1301-1327
1328-1354
1355-1381
1382-1408
>1409

hours

61.85
2.05
3.10
4.00
3.95
4.50
7.65
8.65
27.90
301.05
1729.50
1996.30
812.10
20.55
1.50
0.40
0.00
0.00
0.00
0.00
0.00
0.00
0.00

1.24
0.04
0.06
0.08
0.08
0.09
0.15
0.17
0.56
6.04
34.69
40.05
16.29
0.41
0.03
0.01
0.00
0.00
0.00
0.00
0.00
0.00
0.00

Monitoring System - 3516B Engine - Genset #1 (1HZ03948)


Description
Altitude (atmospheric
pressure)

State

Trip Point

Delay Time

Moderate Severity (2)


Engine Overspeed
Least Severe (1)
Most Severe (3)
High Aftercooler
Coolant Temperature
Least Severe (1)
Moderate Severity (2)
Most Severe (3)
High Air Filter
Restriction Pressure
Least Severe (1)
Moderate Severity (2)
High Boost Pressure
Least Severe (1)
Moderate Severity (2)
High Crankcase
Pressure
Least Severe (1)
Moderate Severity (2)
Most Severe (3)
High Engine Coolant
Temperature
Least Severe (1)
Moderate Severity (2)
Most Severe (3)
High Engine Oil Filter
Restriction Pressure
Least Severe (1)
High Exhaust
Temperature
Least Severe (1)
Moderate Severity (2)
High Fuel Filter
Restriction Pressure
Least Severe (1)
Low Aftercooler
Coolant Level
Least Severe (1)
Most Severe (3)
Low Coolant Level
Least Severe (1)
Most Severe (3)
Low Engine Coolant
Temperature
Least Severe (1)
Low Engine Oil
Pressure
Least Severe (1)
Most Severe (3)

On

13.5 psi

0 sec

On
On

1770 rpm
1770 rpm

0 sec
0 sec

On
On
On

216 Deg F
225 Deg F
225 Deg F

5 sec
5 sec
5 sec

On
On

28.1 " H2O


28.1 " H2O

5 sec
5 sec

Off
Off

58.0 psi
58.0 psi

0 sec
0 sec

On
On
On

8.0 " H2O


24.1 " H2O
14.1 " H2O

3 sec
10 sec
3 sec

On
On
On

216 Deg F
225 Deg F
225 Deg F

5 sec
30 sec
5 sec

On

15 psi

5 sec

On
On

1342 Deg F
1342 Deg F

5 sec
5 sec

On

15 psi

5 sec

On
Off

None
None

30 sec
30 sec

On
Off

None
None

30 sec
30 sec

On

176 Deg F

5 sec

On
On

None
None

4 sec
9 sec

Low Fuel Pressure


Most Severe (3)
Low System Voltage
Least Severe (1)

On

32 psi

20 sec

On

20 Volts

10 sec

Injector Codes Calibration - 3516B Engine - Genset #1 (1HZ03948)


Injector
Injector 1
Injector 2
Injector 3
Injector 4
Injector 5
Injector 6
Injector 7
Injector 8
Injector 9
Injector 10
Injector 11
Injector 12
Injector 13
Injector 14
Injector 15
Injector 16

Code
1327
1322
2105
6830
7952
5510
7930
6957
3101
5615
5940
7717
2762
1770
3420
2426

Digital Voltage Regulator


Parameter
ECM Part Number
ECM Serial Number
Software Group Part Number
Software Group Release Date
Software Group Description

Value
3147755-00
36116122GD
3611006-00
APR2011
Regulator Software

Logged Diagnostic Codes [Diagnostic Clock = 4973 hours] - Digital Voltage Regulator
Code
628-12

Description
Occ.
Program Memory : Failure 1

SMH First
0:00:00

SMH Last
0:00:00

RTC First
1/1/2000

RTC Last
1/1/2000

Logged Event Codes [Diagnostic Clock = 4973 hours] - Digital Voltage Regulator
Code
2456-17

Description
Occ.
Generator Total Reactive 99
Power : Low - least
severe (1)

SMH First
226:18:00

Active Diagnostic Codes - Digital Voltage Regulator


Code
No Active
Codes

Description

Active Event Codes - Digital Voltage Regulator


Code
Description

SMH Last RTC First RTC Last


4916:12:00 5/31/2012 7/13/2014
1:27:48 AM 2:08:36 PM

No Active
Events
Configuration - Digital Voltage Regulator
Description
Voltage Regulator Settings Support Type
Generator Rated Voltage #1
Generator Rated Frequency #1
Generator Rated Current #1
Generator Nominal Output Voltage #1
Voltage Regulator Corner Frequency #1
Voltage Regulator Minimum Frequency
Threshold #1
Voltage Regulator Power Input Frequency
Configuration #1
Generator Rated Voltage #2
Generator Rated Frequency #2
Generator Rated Current #2
Generator Nominal Output Voltage #2
Voltage Regulator Corner Frequency #2
Voltage Regulator Minimum Frequency
Threshold #2
Voltage Regulator Power Input Frequency
Configuration #2
Generator Rated Voltage #3
Generator Rated Frequency #3
Generator Rated Current #3
Generator Nominal Output Voltage #3
Voltage Regulator Corner Frequency #3
Voltage Regulator Minimum Frequency
Threshold #3
Voltage Regulator Power Input Frequency
Configuration #3
Generator Rated Voltage #4
Generator Rated Frequency #4
Generator Rated Current #4
Generator Nominal Output Voltage #4
Voltage Regulator Corner Frequency #4
Voltage Regulator Minimum Frequency
Threshold #4
Voltage Regulator Power Input Frequency
Configuration #4
Voltage Regulator Power Input Frequency
Configuration
Potential Transformer Primary Winding
Rating
Potential Transformer Secondary Winding
Rating
Current Transformer Primary Winding
Rating

Value
Multiple
480
60.00
2744
480
59.8
39.0

Unit

240.00

Hz

120
60.00
600
120
50.0
25.0

Volts
Hz
Amps
Volts
Hz
Hz

60.00

Hz

400
50.00
2310
400
49.8
23.0

Volts
Hz
Amps
Volts
Hz
Hz

200.00

Hz

120
60.00
600
120
50.0
25.0

Volts
Hz
Amps
Volts
Hz
Hz

60.00

Hz

Disabled or Not Installed

Hz

120

Volts

120

Volts

3000

Amps

Volts
Hz
Amps
Volts
Hz
Hz

Current Transformer Secondary Winding


Rating
Generator Connection Configuration
Generator Rated Frequency
Generator Rated Voltage
Generator Rated Current
Voltage Regulator Loss of Sensing
Shutdown Event Notification Delay Time
Generator Rotating Diode Monitor
Shutdown Event Current Threshold
Generator Reverse VAr Shutdown Event
Percentage Threshold
Generator Reverse VAr Shutdown Event
Notification Delay Time
Generator Reverse VAr Shutdown Event
Response Configuration
Generator Over Voltage Shutdown Event
Percentage Threshold
Generator Over Voltage Shutdown Event
Notification Delay Time
Generator Over Voltage Shutdown Event
Response Configuration
Generator Under Voltage Shutdown Event
Percentage Threshold
Generator Under Voltage Shutdown Event
Notification Delay Time
Generator Under Voltage Shutdown Event
Response Configuration
Voltage Regulator Over Excitation
Shutdown Event Threshold
Voltage Regulator Over Excitation
Shutdown Event Notification Delay Time
Voltage Regulator Over Excitation
Shutdown Event Notification Delay Type
Voltage Regulator Fault Reset Switch
Diagnostic Response Configuration
Generator Nominal Output Voltage
Voltage Regulator Corner (Knee)
Frequency
Voltage Regulator Deviation From Corner
(Knee) Frequency
Voltage Regulator Volts/Hz Slope 1
Voltage Regulator Volts/Hz Slope 2
Voltage Regulator Minimum Voltage
Setpoint Percentage
Voltage Regulator Minimum Frequency
Threshold
Voltage Regulator Maximum Droop
Percentage
Voltage Regulator Voltage (IR)
Compensation Percentage
Voltage Regulator Starting Time
Voltage Regulator Starting Voltage Percent

Amps

Three Phase
Disabled or Not Installed
Disabled or Not Installed
Disabled or Not Installed
2.0

Volts
Amps
sec

2.0

Amps

10

3.0

sec

Activate Warning Condition


135

sec

Activate Warning Condition


60

30

sec

Activate Warning Condition


12.0

Amps

10.0

sec

Definite Time
Activate Warning Condition
Disabled or Not Installed
Disabled or Not Installed

Volts
Hz

5.0

Hz

2.0
2.0
50.0

V/Hz
V/Hz
%

Disabled or Not Installed

Hz

0.0

0.0

5.0
10.0

sec
%

Voltage Regulator Noise Filter Time


Constant
Voltage Regulation Proportional Gain
Percentage
Voltage Regulation Integral Gain
Percentage
Voltage Regulation Derivative Gain
Percentage
Voltage Regulator Gain Setting Selection
Number
Voltage Regulator Gain Setting Type
Configuration
Voltage Regulator Loop Gain Percentage
Maximum Generator Voltage Output Bias
Percentage Setpoint
Desired Voltage Input Configuration
Voltage Regulator Programmable Digital
Input Function Configuration
Generator Nominal Output Power Factor
Voltage Regulator Nominal Reactive Power
Percentage
Generator Power Factor Controller Loop
Gain Percentage
Generator Power Factor Controller Integral
Gain Percentage
Voltage Regulator Load Compensation
Type Configuration
Voltage Regulator Power Factor/VAr
Controller Mode Selection
Voltage Regulator Desired Power Factor
Configuration
Generator VAr Controller Loop Gain
Percentage
Generator VAr Controller Integral Gain
Percentage
VAr / Power Factor Control Input
Configuration

0.08

sec

2.08

1.49

0.26

7
User Defined
5.00
15

%
%

CAN Input
Fault Reset
1.00
0.0

0.30

0.50

Voltage Droop
Reactive Power
Lagging
0.25

0.50

Hardwired Input