You are on page 1of 32

Model S

Model SX

Model V

Model MSR

Variable Air Volume (VAV) Terminal Units


Single Duct

Dual Duct

Low Prole

Bypass Air

Tailor Your Atmosphere

About Us
Heating & Air Conditioning Enterprises have recently grouped the names of its divisions
(HACE Royal Temp Golden Star) into (HACE), while preserving the companys good
reputation and expertise acquired in the past 30 years for providing high quality HVAC
products, supplies and services.
HACE took the advantage of the strongly increasing demand on its high quality products
and launched numerous expansion plans to increase the production capacity by double,
increase the working staff by 30%, provide totally new products with wider range of
choice, release new HVAC products series with new specifications and develop the
existing products and services. HACE is based on a production facility of 30000 m along
with a storage area of 5750 m. HACE team consists of more than 500 highly skillful
technical and senior engineers.
In 1976 HACE started the manufacturing of HVAC products and supplies in the Kingdom of
Saudi Arabia. In 1980, the primary manufacturing plant was built in the Second Industrial
City in Riyadh and from that point, HACE started the manufacture of air conditioning
equipment, air devices, heavy duty centrifugal blowers, and pre-insulated pipes under
the trade name Goldenstar. In 2004, the company trade name was changed to Royal
Temp and to be used for all products. In 2012, the name HACE was chosen to replace the
old trade names and declare a new milestone in the companys history.
In continuation of its growth pursuit, HACE is eagerly following the recent HVAC
technologies and developments by providing its employees with the best training
sessions coupled with its wide knowledge of HVAC sciences and products. HACE high
quality equipment has acquired various international certifications like AHRI, ETL, UL, CE,
and ISO 9001 along with many vendor approvals from the governmental sector, semigovernmental and leading private companies.

www.hace.com.sa

Today, HACE is producing a huge variety of HVAC products, supplies and services that
will grant all of its customers air comfort requirements to the least detail, Tailor Your
Atmosphere.

Our Vision
Become customers first choice regionally and be recognized globally for providing high
quality air comfort solutions.

Our Mission
Ensure total customer satisfaction for Air Comfort requirements by providing high quality,
tailored, affordable, energy efficient and eco-friendly products and services.

Table of
Contents
Contents

Introduction & Description Of Unit Operation............................................................ 2


HACE VAV models....................................................................................................... 3
Model - (S)
general specification.......................................................................................... 3
sound power data.............................................................................................. 4
Dimensional data .............................................................................................. 6
Model - (SX)
general specification.......................................................................................... 7
sound power data.............................................................................................. 8
Dimensional data ............................................................................................... 10
Model - (V)
general specification.......................................................................................... 11
sound power data.............................................................................................. 12
Dimensional data ............................................................................................... 14
Model - (MSR)
general specification.......................................................................................... 15
sound power data.............................................................................................. 16
Dimensional data ............................................................................................... 17
Optional Features........................................................................................................ 18
Optional Electric resistance heater ........................................................................... 19
Hot water heating coil option................................................................................... 22
Arrangement codes for (s & msr models) ................................................................ 28

INTRODuCTION & DESCRIPTION OF UNIT OPERATION

INTRODuCTION
The variable air volume (vav) system is applicable to the most building in which may be successfully applied to all-air
types of air conditioning system. the objective of heating, ventilating and air conditioning (hvac) system is to satisfy
users when it comes to health, indoor air quality (iaq), and thermal comfort. air conditioning systems employed to
provide thermal comfort and indoor air quality consume a significant part of the building energy requirement. compared
with other all air systems, such as double duct & multi-zone, the variable air volume system offers inherent savings in
both installation and operating costs. a variable air volume (vav) system enables 24% to 20% energy savings in the
chiller and 20% to 48% for the fan system.

APPLICATION
Variable air volume systems are widely used where individual zone control is desired, such as commercial buildings,
hospitals and schools. Where simultaneous heating and cooling of different areas within a structure are required, the
variable air volume system can be coupled with a supplementary heating system. This system may be simply a hot water
coil or an electric radiation type for perimeter heating, and may be coupled with a sound attenuator, a multiple-outlet
attenuator, a multiple-outlet octopus, etc.
A variable air volume system can be installed in an existing high energy air system for system energy conservation.

DESCRIPTION OF UNIT OPERATION


HACE variable air volume terminal units are controlled to provide varying amounts of conditioned air to a space in
response to a room thermostat.
When used in a cooling application, cold air is supplied to the terminal unit; as the room temperature increases above
the set point of the thermostat, a signal is sent to open the terminal unit damper. This allows more cold air to be
delivered to the space.
When the room temperature falls less than the thermostat set point, a signal is sent to close the terminal unit damper,
decreasing the amount of cold air delivered to the space.
When used in a heating application, warm air is supplied to the terminal unit; as the room temperature increases above
the set point of the thermostat, a signal is sent to close the terminal unit damper. This decreases the amount of warm
air delivered to the space.
When the temperature falls less than the thermostat set point, a signal is sent to open the terminal unit damper,
increasing the amount of warm air delivered to the space.
The terminal units may also be used for constant volume control. When used in constant air volume systems, a manually
adjustable damper quadrant may be provided to lock the damper in the position necessary to deliver the required air
flow, based on the actual entering static pressure. When constant air volume to a specific zone is required in a variable
air volume system, controls must be provided that will maintain that constant volume, regardless of changes in the duct
static pressure.
Since certain zones in commercial buildings may require simultaneous cooling and heating (even during winter) VAV
boxes can also include reheat coils (either electric or hot water), to provide heat as a secondary simultaneous process
to the primary air or re-circulated room air to meet the space set point.

p a g e

HACE VAV - MODELS / single Duct Terminal Unit - Model (S)

DAMPER CONTROL METHODS


VAV boxes typically operate in two basic methods of controlling the unit damper. They are referred to as pressure-dependent
and pressure-independent.

Pressure-dependent
Thermostat directly controls the position of the damper. The volume of air is determined by the damper actuator position
and VAV inlet static pressure.

Pressure-independent (independent of static pressure entering VAV)


The quantity of airflow to the space is measured at the VAV based on feedback from an airflow-measuring device in the box.
The thermostat controls the volume of air to the zone space. A minimum and maximum airflow are calibrated for each VAV
and the thermostat will control the air volume within this range. The thermostat does not directly control the position of the
damper actuator.

HACE VAV - MODELS *


-

MODEL (S): SINGLE DUCT TERMINAL, SINGLE OUTLET; AIRFLOW UP TO 10,000 CFM.
MODEL (SX): DUAL DUCT TERMINAL ; AIRFLOW UP TO 2,400 CFM.
MODEL (V): LOW PROFILE TERMINAL, AIRFLOW UP TO 5,000 CFM.
MODEL (MSR): BYPASS TERMINAL ; AIRFLOW UP TO 2,400 CFM ; CUSTOM MADE UP TO 3,000 CFM.

Single Duct Terminal Unit - Model (S)


generl specification
The Model S offers a wide range of unit sizes in airflow capacities to
10,000 CFM in a low profile VAV terminal. The units are designed to
control with minimum static pressure requirements and low noise
operation. Units are certified incompliance with the requirements of
AHRI Standard 880 for air terminals and are Intertek listed complying
with the requirement of UL-429.The Model S unit is provided with
inlets suitable for round duct installations at the discharge, the units
are formed to provide for easy S & Drive connection to down stream
ducts.
The standard model S terminal unit is constructed of heavy 22 gauge zinc-coated steel (galvanized steel), internally lined
with 1 glass fiber material faced with black, strong, durable, and stable woven glass fabric having UL 181 approval against
air erosion and meeting NFPA-90A. The unit damper is constructed of exactly dimensioned extruded anodized aluminum,
mechanically keyed and fastened to a damper shaft which rotates in maintenance free nylon bearings for noiseless operation.
The average damper leakage of all units does not exceed 2% of rated air flow at 3 inlet static pressure.
The Model S terminal unit is available with optional hot water reheat (Model HSW) or electric resistance heat (Model HSE).
The hot water coils are available in one row or two rows configuration. The coils are constructed from 1/2 OD seamless
copper tubes mechanically bonded to aluminum fins. The electric resistance heaters meet the requirement of UL-1996
and National Electric Code (NEC) requirements. Coils are provided with S & Drive connections on the inlet side and flange
connections on the discharge. Standard heater options include automatic primary thermal reset, manual secondary thermal
reset, control line terminal blocks, magnetic contactors or P/E switches as required by heater construction, 80-20 Ni-Ch
heater element, and airflow proving switch with probe.
Note:

*Specifications are subject to change without notice in accordance with our policy of continuos research product development .

p a g e

SOUND POWER DATA - MODEL (S)

SOUND POWER DATA - MODEL (S)


Airflow
CFM

Size

A(5)

B(6)

C(7)

D(8)

E(10)

F(12)

p a g e

Min.
Operating
Pressure, in.

125

250

100
200
250
300
400

0.06
0.06
0.06
0.06
0.06

50
59
64
67
71

56
62
65
67
71

100
200
250
300
400

0.06
0.06
0.06
0.06
0.06

49
56
55
55
62

37
50
53
55
57

200
300
400
450
600

0.05
0.05
0.05
0.06
0.06

56
60
62
64
67

59
63
66
67
71

200
300
400
450
600

0.05
0.05
0.05
0.06
0.06

51
56
60
64
67

46
51
54
56
60

200
400
550
600
800

0.05
0.05
0.05
0.05
0.05

47
52
64
58
61

39
49
66
54
58

200
400
550
600
800

0.05
0.05
0.05
0.05
0.05

46
55
58
61
64

42
52
55
57
61

300
500
700
750
1000

0.09
0.10
0.12
0.13
0.15

59
64
68
69
74

57
63
66
67
71

300
500
700
750
1000

0.09
0.10
0.12
0.13
0.15

51
57
61
62
65

48
55
58
59
62

450
750
1100
1125
1500

0.13
0.15
0.17
0.18
0.20

59
65
69
71
74

61
66
69
70
73

450
750
1100
1125
1500

0.13
0.15
0.17
0.18
0.20

52
58
61
62
65

52
57
60
61
64

800
1200
1600
2000

0.07
0.14
0.20
0.32

65
70
74
75

65
69
72
74

800
1200
1600
2000

0.07
0.14
0.20
0.32

57
62
65
68

54
59
61
63

Discharge

Radiated

Discharge

Radiated

Discharge

Radiated

Discharge

Radiated

Discharge

Radiated

Discharge

Radiated

Intel @ 1.50 Ps
Octave Bands
500
1000

2000

4000

51
57
59
61
65

46
49
52
54
57

39
43
45
47
50

38
41
43
45
48

39
51
51
54
55

41
47
49
50
53

30
36
38
39
41

21
24
26
28
33

55
58
60
62
66

47
50
52
53
57

40
44
46
47
50

40
44
47
49
53

45
48
51
53
55

44
45
49
49
52

33
34
37
40
42

27
29
31
32
35

35
43
60
47
51

31
36
53
39
43

35
30
51
33
36

37
25
52
27
30

42
50
52
54
58

42
60
49
50
54

32
33
35
36
39

25
40
29
30
33

54
58
60
61
65

49
52
54
55
59

45
49
52
53
55

45
50
54
55
57

46
51
54
55
58

43
48
49
51
54

31
35
37
38
71

28
30
32
33
37

56
60
63
64
67

52
54
58
57
60

49
51
53
54
56

49
52
54
55
57

49
53
55
57
61

45
51
53
54
56

32
37
39
40
43

27
31
34
35
39

60
63
66
69

55
57
60
63

52
54
56
59

53
55
57
60

53
56
59
62

59
56
55
58

35
41
41
43

27
31
33
37

SOUND POWER DATA - MODEL (S)

CONTINUING SOUND POWER DATA - MODEL (S)


Airflow
CFM

Size

Min.
Operating
Pressure, in.

125

250

Intel @ 1.50 Ps
Octave Bands
500
1000

2000

4000

Discharge

G(14)

1000
1500
2100
2250
3000

0.07
0.10
0.14
0.17
0.29

64
69
71
73
77

1000
1500
2100
2250
3000

0.07
0.10
0.14
0.17
0.29

59
63
64
66
70

1000
2000
2800
3000
4000

0.06
0.16
0.24
0.32
0.55

62
73
75
76
78

1000
2000
2800
3000
4000

0.06
0.16
0.24
0.32
0.55

58
69
72
74
77

1250
2500
3500
3750
5000

0.06
0.17
0.29
0.35
0.59

64
74
76
77
80

1250
2500
3500
3750
5000

0.06
0.17
0.29
0.35
0.59

59
70
73
75
78

1750
3500
4400
5200
7000

0.05
0.12
0.15
0.25
0.38

71
76
77
78
80

1750
3500
4400
5200
7000

0.05
0.12
0.15
0.25
0.38

63
70
71
72
76

2500
5000
6300
7500
10000

0.07
0.17
0.23
0.35
0.59

74
80
81
81
84

2500
5000
6300
7500
10000

0.07
0.17
0.23
0.35
0.59

68
74
76
77
80

65
69
71
73
76

61
64
68
68
72

56
58
60
62
66

53
55
57
58
61

55
56
57
58
62

54
57
58
61
65

50
53
54
56
61

37
40
41
43
48

31
34
35
37
42

57
69
71
72
75

54
61
65
65
68

48
56
57
58
61

47
56
58
59
61

53
61
63
65
69

53
58
60
61
66

41
46
49
50
55

31
40
43
45
50

59
72
74
75
77

57
64
67
68
71

50
58
59
60
62

47
57
58
59
61

53
63
65
67
71

56
60
62
66
68

44
49
51
53
56

34
42
45
47
53

66
71
71
72
73

56
62
65
66
70

51
57
59
60
64

57
60
60
61
66

55
61
62
64
69

54
57
58
60
65

40
48
46
47
51

29
37
41
42
49

70
74
75
76
79

60
67
69
70
75

56
62
64
65
69

63
64
66
67
71

59
65
68
68
73

58
61
64
64
69

44
48
51
52
55

35
42
47
48
54

Radiated
57
61
62
64
68

Discharge

H(16)

59
73
76
77
79

Radiated
53
64
66
68
72

Discharge

J(18)

61
76
79
80
82

Radiated
55
66
68
70
74

Discharge

K(20)

72
77
77
78
81

Radiated
56
64
65
67
72

Discharge

M(24)

76
80
81
82
85

Radiated

60
68
71
72
76

p a g e

Dimensional Data - MODEL (S)

Dimensional Data - MODEL (S)

PA

Size

A
24
24
24
24
24
24
24
24
24
24
24

A
B
C
D
E
F
G
H
J
K
M

B
9
9
12
12
14
17
22
27
36
27
36

V
10
10
10
10
10
10
10
10
10
18
18

Dimension, inches
D
OVAL SIZE
5
N/A
6
N/A
7
N/A
8
N/A
10*
7.88 x 11.02
12*
7.88 x 14.16
14*
7.88 x 17.30
16*
7.88 x 20.44
18*
7.88 x 23.58
20*
15.88 x 22.16
24*
15.88 x 28.44

E
8
8
8
8
8
8
8
8
8
16
16

F
8
8
11
11
13
16
21
26
35
26
35

S
15
16
17
18
19
23
29
35
40
48
60

Weight (lbs) **
HSW
20
21
23
24
26
31
39
47
55
79
105

legends:
PA: primary airflow.
SA: Supply airflow.
* Supplied with flat ovel collar; all other collars are round.
** Wieghts are average; actual weights may vary depending on unit and control options.

p a g e

HSE
33
34
35
36
39
45
54
62
72
86
106

Dual Duct Terminal Unit - Model (SX)

Dual Duct Terminal Unit - Model (SX)


general specification
The Model SX offers a wide range of unit sizes in airflow capacities to 2,400
CFM in a low profile VAV terminal. The units are designed to control with
minimum static pressure requirements with extremely low noise operation
due to smooth mixing of the hot and cold airflows and internal acoustical
treatment in the attenuator mixing section. Units are certified in compliance
with the requirements of AHRI Standard 880 for air terminals. The Model
SX unit is provided with inlets suitable for round duct installations. at the
discharge, the units are formed to provide for easy S & Drive connection to
down stream ducts.

The standard model SX terminal unit is constructed of heavy 22 gauge zinc-coated steel (galvanized steel), mixer/attenuator
section, internally lined with 1 glass fiber material faced with black, strong, durable, and stable woven glass fabric having
UL 181 approval against air erosion and meeting NFPA-90A. The unit dampers are constructed of exactly dimensioned
extruded anodized aluminum, mechanically keyed and fastened to a damper shaft which rotates in maintenance free
nylon bearings for noiseless operation.
The Model SX double duct terminal unit is a versatile product that can be adapted to numerous control schemes to suit
job requirements. It can provide constant volume for those special cases requiring constant airflow in the space, it can
provide constant volume on one duct and variable on the other or it can provide variable volume on both ducts with
or without mixing of hot and cold airflows. Selecting an airflow sequence that minimizes airflow mixing reduces energy
consumption.

p a g e

SOUND POWER DATA - MODEL (SX)

SOUND POWER DATA - MODEL (SX)


Size

Airflow
CFM

Min.
Operating
Pressure, in.

125

Inlet @ 1.50Ps
Octave Bands
500
1000

250

2000

4000

Discharge

A(5)

120

0.04

51

53

49

45

46

41

160

0.05

56

58

53

49

50

45

200

0.06

60

61

55

51

52

47

240

0.07

63

63

57

53

54

49

250

0.08

63

63

57

53

54

49

Radiated
120

0.04

48

43

42

36

31

29

160

0.05

54

48

46

41

34

32

200

0.06

58

52

49

43

36

33

240

0.07

61

54

51

45

37

34

250

0.08

61

54

51

45

37

34

Discharge

B(6)

240

0.08

59

61

57

52

52

48

320

0.11

64

65

59

55

54

51

400

0.14

67

67

61

56

56

52

480

0.18

69

68

61

57

57

53

240

0.08

58

52

50

44

38

36

320

0.11

63

57

53

47

40

38

Radiated

400

0.14

66

59

56

48

41

38

480

0.18

67

61

57

48

41

39

360

0.10

63

65

60

56

54

51

480

0.15

67

68

63

58

56

54

Discharge

C(7)

550

0.20

70

70

64

59

57

55

600

0.21

70

70

64

59

57

55

720

0.28

72

71

64

60

58

56

Radiated
360

0.10

62

57

54

48

42

40

480

0.15

66

61

57

50

43

41

550

0.20

69

63

59

50

44

41

600

0.21

69

63

59

50

44

41

720

0.28

71

65

60

51

45

42

Discharge

D(8)

480

0.13

65

67

63

58

55

53

640

0.20

69

70

65

60

57

56

700

0.25

72

71

66

61

58

56

800

0.28

72

71

66

61

58

56

960

0.38

74

73

66

62

59

57

Radiated

p a g e

480

0.13

64

60

56

50

44

42

640

0.20

68

63

59

52

46

44

700

0.25

71

66

61

52

46

44

800

0.28

71

66

61

52

46

44

960

0.38

73

67

63

53

47

45

SOUND POWER DATA - MODEL (SX)

continiuing SOUND POWER DATA - MODEL (SX)


Airflow
CFM

Size

Min.
Operating
Pressure, in.

Inlel @ 1.50Ps
Octave Bands
125

250

500

1000

2000

4000

Discharge

E(10)

720

0.17

67

71

66

62

56

56

960

0.26

71

73

68

64

59

58

1100

0.31

74

74

69

64

60

59

1200

0.38

74

74

69

64

60

59

1400

0.52

76

75

69

65

60

59

60

53

48

46

Radiated
720

0.17

67

63

960

0.26

71

67

63

55

49

48

1100

0.31

73

69

64

55

50

48

1200

0.38

73

69

64

55

50

48

1400

0.52

75

71

66

55

50

49

960

0.18

68

71

69

64

57

58

Discharge

F(12)

1280

0.30

72

74

71

66

60

60

1600

0.14

75

76

71

67

61

61

1920

0.59

76

76

71

67

61

61

Radiated
960

0.18

68

66

62

55

51

49

1280

0.30

72

70

65

57

52

51

1600

0.41

75

71

66

57

52

51

1920

0.59

76

73

68

57

53

51

1200

0.19

69

72

70

66

57

59

Discharge

G(14)

1600

0.31

73

76

73

68

60

62

2000

0.46

76

77

74

69

61

62

2100

0.48

77

78

73

68

62

62

2400

0.63

77

78

73

68

62

62

1200

0.19

68

67

63

56

53

52

Radiated

1600

0.31

73

71

67

59

55

53

2000

0.46

76

73

68

60

55

54

2100

0.48

77

75

69

60

55

54

2400

0.63

77

75

69

59

55

54

p a g e

Dimensional Data - MODEL (SX)

Dimensional Data - MODEL (SX)

OPTIONAL CONTROL
ENCLOSRES
D * 6 LONG
INLET COLLAR
Pa

5.5
Pa

3
8

Pa

k
sa

S & DRNE
OPTIONAL BOTTOM
ASSESS PANEL

Pa

j
c

f
b

INLET CONNECTINS

MODEL SX
TERMINAL UNTT

Dimensions, inches
A

OVAL SIZE

Weight
(lbs) **

24

16

10

N/A

10

4.5

29

24

20

10

N/A

14

5.5

44

24

23

10

N/A

3.5

16

54

24

26

10

N/A

18

12

69

24

32

10

10*

7.88x11.02

22

8.5

15

79

24

42

10

12*

7.88x14.16

30

11

20

98

24

52

10

14*

7.88x17.30

38

13.5

25

119

Size

legends:
PA: primary airflow.
SA: Supply airflow.
* Supplied with flat oval collar; all other collars are round.
** Weights are average; actual weights may vary depending on unit and control options.

p a g e

10

LOW PROFILE Terminal Unit - Model (V)

LOW PROFILE Terminal Unit - Model (V)


general specification
The Model V offers a wide range of unit sizes in airflow capacities
to 5,000 CFM in a low profile VAV terminal. The units are designed
to control with minimum static pressure requirements and
low noise operation. Units are certified in compliance with the
requirements of AHRI Standard 880 for air terminals. The Model
V unit is provided with inlets suitable for round duct installations.
at the discharge, the units are formed to provide easy S & Drive
connection to down stream ducts.
The standard model V terminal unit is constructed of heavy 22 gauge zinc-coated steel (galvanized steel), internally lined
with 1 glass fiber material faced with black, strong, durable, and stable woven glass fabric having UL 181 approval against
air erosion and meeting NFPA-90A. The unit damper is constructed of exactly dimensioned extruded anodized aluminum,
mechanically keyed and fastened to a damper shaft which rotates in maintenance free nylon bearings for noiseless
operation. The average damper leakage of all units does not exceed 2% of rated airflow at 3 inlet static pressure.
The Model V terminal unit is available with optional hot water reheat (Model HVW). The hot water coils are available in
one row or two rows configuration. The coils are constructed from 1/2 OD seamless copper tubes mechanically bonded
to aluminum fins. Coils are provided with S & Drive connections on the inlet side and flange connections on the discharge.

The Model V terminal units can be paired together (Model VX) for perimeter applications in a dual duct system where
mixing is not required. The wide open pressure characteristic of the Model VX makes it ideal for installation in existing low
pressure constant volume dual duct systems to achieve variable volume energy savings.

p a g e

11

Sound Power Data - Model (V)

Sound Power Data - Model (V)


Size

A(5)

B(6)

C(7)

D(8)

E(10)

F(12)

p a g e

12

Min.
Operating
Pressure, in.

125

250

100
200
250
300
400

0.07
0.08
0.09
0.10
0.11

51
61
69
69
74

58
68
73
73
77

100
200
250
300
400

0.07
0.08
0.09
0.10
0.11

57
62
62
63

59
61
61
62

200
300
400
450
600

0.06
0.07
0.08
0.09
0.10

59
63
69
69
73

65
70
74
74
77

200
300
400
450
600

0.06
0.07
0.08
0.09
0.10

51
57
63
63
66

48
55
59
59
62

200
400
550
600
800

0.06
0.07
0.08
0.09
0.10

53
66
68
68
70

51
69
71
71
71

200
400
550
600
800

0.06
0.07
0.08
0.09
0.10

45
57
62
62
64

42
55
60
60
62

300
500
700
750
1000

0.07
0.09
0.12
0.13
0.17

62
66
69
69
71

68
72
75
75
76

300
500
700
750
1000

0.07
0.09
0.12
0.13
0.17

50
57
60
60
62

48
56
59
59
61

450
750
1000
1125
1500

0.06
0.09
0.14
0.15
0.19

61
67
72
72
73

67
71
75
75
77

450
750
1000
1125
1500

0.06
0.09
0.14
0.15
0.19

55
59
62
62
64

57
61
64
64
65

800
1200
1600
2000

0.11
0.17
0.25
0.38

65
67
71
74

68
71
73
76

800
1200
1600
2000

0.11
0.17
0.25
0.38

58
61
64
67

57
59
61
63

Air flow
CFM

Discharge

Intel @ 1.50 Ps
Octave Bands
500
1000

2000

4000

53
66
69
69
72

56
61
65
65
67

52
58
61
61
64

49
54
57
57
59

30
53
57
57
58

24
47
51
51
51

27
44
47
47
47

35
43
44
44
46

65
68
70
70
71

59
65
66
66
68

56
60
61
61
63

53
56
57
57
60

44
50
53
53
56

39
45
49
49
52

35
40
44
44
47

32
33
37
37
41

53
67
68
68
68

53
62
62
62
64

38
58
60
60
60

38
55
57
57
57

39
51
56
56
56

40
47
51
51
50

33
42
46
46
45

25
37
41
41
40

66
59
68
68
70

63
64
63
63
66

59
60
60
60
63

55
56
58
58
60

44
54
56
56
58

40
49
51
51
52

36
46
50
50
51

30
40
45
45
46

66
68
72
72
73

64
65
68
68
70

61
62
64
64
66

57
58
61
61
63

54
57
58
58
60

49
52
52
52
53

45
48
47
47
48

41
45
42
42
44

68
69
72
74

66
67
69
71

62
62
65
67

57
59
62
64

52
54
56
58

44
47
49
51

38
41
43
46

33
36
42
43

Radiated

Discharge

Radiated

Discharge

Radiated

Discharge

Radiated

Discharge

Radiated

Discharge

Radiated

Sound Power Data - Model (V)

continiuing Sound Power Data - Model (V)


Air flow
CFM

Size

Min.
Operating
Pressure, in.

Inlet @ 1.50Ps
Octave Bands
125

250

500

1000

2000

4000

Discharge

G(14)

1000

0.11

66

68

67

66

62

58

1500

0.13

69

72

71

68

64

60

2100

0.21

73

76

73

70

66

63

2250

0.23

73

76

73

70

66

63

3000

0.34

77

79

76

73

70

66

1000

0.11

59

61

60

56

52

50

Radiated
1500

0.13

62

62

57

52

47

44

2100

0.21

66

65

60

53

48

43

2250

0.23

66

65

60

53

48

43

3000

0.34

70

68

62

55

50

44

1000

0.10

60

59

69

64

54

48

Discharge

H(16)

2000

0.21

66

69

71

65

63

57

2800

0.42

70

71

71

66

64

59

3000

0.44

70

71

71

66

64

59

4000

0.70

72

72

73

68

66

61

1000

0.10

53

53

57

52

52

44

Radiated
2000

0.21

68

68

68

61

61

56

2800

0.42

67

71

69

60

60

56

3000

0.44

67

71

69

60

60

56

4000

0.70

68

69

70

59

60

56

1250

0.10

59

58

70

64

54

47

Discharge

J(18)

2500

0.21

67

68

71

64

63

56

3500

0.41

70

70

72

68

64

58

3750

0.43

70

70

72

68

64

58

5000

0.69

72

71

73

68

66

60

Radiated

1250

0.10

53

54

60

53

54

44

2500

0.21

65

69

71

62

63

56

3500

0.41

67

72

72

61

62

57

3750

0.43

67

72

72

61

62

57

5000

0.69

68

73

73

61

62

56

p a g e

13

Dimensional Data - MODELS (v)

Dimensional Data - MODELS (v)

Size
A
B
C
D
E
F
G
H
J

A
12
12
12
12
12
12
12
12
12

B
9
9
12
12
14
17
22
27
36

Dimension, inches
C
D
10
5
10
6
10
7
10
8
10
10*
10
12*
10
14*
10
16*
10
18*

OVAL SIZE
N/A
N/A
N/A
N/A
7.88 x 11.02
7.88 x 14.16
7.88 x 17.30
7.88 x 20.44
7.88 x 23.58

Weight (lbs) **
V
HVW
10
15
10
15
12
18
12
18
14
21
15
23
19
28
22
33
27
42

legends:
PA: primary Airflow.
SA: Supply Airflow.
* Supplied with flat oval collar; all other collars are round.
** Weights are average; actual weights may vary depending on unit and control options.

p a g e

14

Bypass Terminal Unit - Model (MSR)

Bypass Terminal Unit - Model (MSR)


GENERAL SPECIFICATION
The Model MSR relief type VAV terminal offers a wide range of unit sizes
in airflow capacities to 2,400 CFM. The units are designed to control
low to medium velocity, constant volume air distribution systems. Units
are certified in compliance with the requirements of AHRI Standard 880
for air terminals. Because of the unique field adjustable air balancing
damper included in the bypass section of the MSR terminal unit, the
static pressure loss through the unit can be matched at the bypass to
the return air plenum.

The Model MSR unit is provided with inlets suitable for round duct installations. At the discharge, the units are formed to
provide easy S & Drive connection to down stream ducts.
The standard Model MSR terminal unit is constructed of heavy 22 gauge zinc-coated steel (galvanized steel), internally
lined with 1 glass fiber material faced with black, strong, durable, and stable woven glass fabric having UL 181 approval
against air erosion and meeting NFPA-90A. The unit dampers are constructed of exactly dimensioned extruded anodized
aluminum, mechanically keyed and fastened to a damper shaft which rotates in maintenance free nylon bearings for
noiseless operation.
The Model MSR terminal unit is available with optional hot water reheat (Model HMSRW) or electric resistance heat
(Model HMSRE). The hot water coils are available in a 1 row or a 2 row configuration. The coils are constructed from 1/2
OD seamless copper tubes mechanically bonded to aluminum fins. The electric resistance heaters meet the requirement
of UL-1996 and National Electric Code (NEC) requirements.
Coils are provided with S & Drive connections on the inlet side and flange connections on the discharge. Standard heater
options include automatic primary thermal reset, manual secondary thermal reset, control line terminal blocks, magnetic
contactors or P/E switches as required by heater construction, 80-20 Ni-Ch heater element, and airflow proving switch
with probe.

p a g e

15

SOUND POWER DATA - MODEL (MSR)

SOUND POWER DATA - MODEL (MSR)


Size

Airflow
CFM

Min
Operating
Pressure, in.

125

Inlet@ 1.50Ps
Octave Bands
500
1000

250

2000

4000

Discharge

B(6)

120
150
180

0.02
0.04
0.06

41
44
45

34
37
38

120
150
180

0.02
0.04
0.06

41
44
45

34
37
38

240
300
360

0.03
0.05
0.07

42
44
46

35
39
43

240
300
360

0.03
0.05
0.07

42
44
46

35
39
43

400
500
600

0.03
0.05
0.07

43
45
48

39
44
46

400
500
600

0.03
0.05
0.07

43
45
48

39
44
46

600
750
900

0.04
0.06
0.09

48
51
55

46
50
54

600
750
900

0.04
0.06
0.09

48
51
55

46
50
54

800
1000
1200

0.04
0.07
0.10

48
50
57

46
51
55

800
1000
1200

0.04
0.07
0.10

48
50
57

46
51
55

1200
1500
1800

0.04
0.06
0.08

49
52
59

47
53
57

1200
1500
1800

0.04
0.06
0.08

49
52
59

47
53
57

1600
2000
2400

0.05
0.08
0.12

51
54
60

48
55
59

1600
2000
2400

0.05
0.08
0.12

51
54
60

48
55
59

27
31
32

23
27
28

20
24
25

18
22
23

27
31
32

23
27
28

20
24
25

18
22
23

28
32
38

24
28
34

21
26
29

19
23
25

28
32
38

24
28
34

21
26
29

19
23
25

35
39
41

31
35
38

27
31
32

24
28
29

35
39
41

31
35
38

27
31
32

24
28
29

43
45
49

40
41
46

37
37
40

34
34
37

43
45
49

40
41
46

37
37
40

34
34
37

43
47
53

40
44
50

38
43
43

34
40
43

43
47
53

40
44
50

38
43
43

34
40
43

44
49
54

42
47
52

40
45
49

36
42
46

44
49
54

42
47
52

40
45
49

36
42
46

48
53
57

45
50
55

42
47
51

38
44
48

48
53
57

45
50
55

42
47
51

38
44
48

Radiated

Discharge

C(7)

Radiated

Discharge

D(8)

Radiated

Discharge

E(10)

Radiated

Discharge

F(12)

Radiated

Discharge

G(14)

Radiated

Discharge

H(16)

p a g e

16

Radiated

Dimensional Data - MODELS (MSR)

Dimensional Data - MODELS (MSR)

DIMENSIONS ; inches

SIZE

WEIGHT ( lbs )

OVAL SIZE

MSR

HMSRW

HMSRE

24

12

10

N/A

11

14

21

27

39

24

12

10

N/A

11

14

21

27

39

24

12

10

9*

7.88 X 9.45

11

14

21

27

39

30

17

10

10*

7.88 X 11.02

16

14

28

36

50

30

17

10

12*

7.88 X 14.16

16

14

28

36

50

36

27

10

14*

7.88 X 17.30

26

14.5

40

52

67

36

34

10

16*

7.88 X 20.44

33

14.5

42

57

74

legends:
PA: primary airflow.
SA: Supply airflow
* Supplied with flat oval collar; all other collars are round.

p a g e

17

Dimensional Data ( Round and Oval Collar ) / OPTIONAL FEATURES

Dimensional Data ( Round and Oval Collar )

NEW COLLER
4
5
6
7
8
*9
* 10
* 12
* 14
* 16
* 18
*
20
* 24

A
3.88
4.88
5.88
6.88
7.88
7.88
7.88
7.88
7.88
7.88
7.88
7.88
7.88

B
9.45
11.02
14.16
17.30
20.44
23.59
26.72
33.01

L
3.5
4.5
5.5
6.5
7.5
8.5
10.5
13.5
16.5
19.5
19.5
19.5
19.5

FLOW SENSOR

ROUNO COLLAR

FLOW SENSOR

ONAL COLLAR
* Supplied with flat oval collar; all other collars are round.

OPTIONAL FEATURES

Electric Resistance Heater.


Hot Water Heating Coil.
Control Valve (on/off or modulating).
Room Thermostat.
DDC (Direct Digital Controller) suitable to connect for BMS.
Sound Attennator.
For more options please contact us.

p a g e

18

Optional Electric Resistance Heater

Optional Electric Resistance Heater


The optional electric resistance heaters are available on single duct terminal unit (model HSE) and bypass type terminal
unit (model HMSRE). Heater casings are provided with S & Drive connections on the inlet side and flange connections
on the discharge. Electric heater frames are constructed of not less than 20 gauge galvanized steel. Heaters are factory
mounted to terminal unit discharge.
Heater construction includes automatic primary disc type thermal reset, manual secondary thermal reset, control
terminal blocks, magnetic contactors, fuses, 80-20% Ni-Ch wire, airflow proving switch with total pressure pick-up probe,
and a control transformer in heaters with electric or electronic control options. Other heater component options include
pilot lamps & disconnect switches.

Electric Heating Capacities


BUH

= HeatER KILOWATT (KW)X3414


CFM
X AIR TEMPERATURE RISE
___________________________
3160

1 Kilowatt (kw)

AIR TEMPERA TURE RISE (DTA)

KW X 3160
___________
CFM

WATTS

(VOLTS)2
___________
RESISTANCE

Electric HeatER AMPERAGE, 1PHASE

WATTS
___________
VOLTS

Electric HeatER AMPERAGE, 3PHASE

WATTS
______________
VOLTS X 1.73

HeatER AIR PRESSURE DROP (in.wg.)

KW/FT2
_________
760

VOLTS X AMPS

(VELOCITY IN FPM)2
X __________________
(500)2

Electric resistance duct heaters output a constant BTU as long as the heater is energized. Therefore, it is important to
maintain proper airflow at minimum required air velocities to prevent nuisance tripping and preclude premature heating
element failure due to over-temperature. The velocity in feet per minute (fpm) is determined by taking the volume of air
(cfm) divided by the duct area:
FPM = CFM/AREA

p a g e

19

OPTIONAL ELECTRIC RESISTANCE HEATER

MINIMUM AIR VELOCITIES


The minimum uniform airflow in a duct heater is directly
related to the inlet air temperature. Consideration must be
given to both the airflow across the heater and the inlet air
temperature.
To calculate the watts per square foot of duct area, divide
the total watts by the square footage of the duct area. Use
the adjacent chart to determine the minimum air velocity
in feet per minute (FPM) based on the inlet entering air
temperature.

notes:
1. label 1,2,3 and 4 are number of rows of heater coil.
2. when number of rows of heater coil is unknown, assume.

p a g e

20

OPTIONAL ELECTRIC RESISTAncE HEATER

HEATING ELEMENT WIRING CONFIGURATIONS

TYPICAL CONTACTOR POWER CIRCUITRY

p a g e

21

HOT WATER HEATING COIL OPTION

SELECTION AND RATING CONDITIONS

SELECTION AND RATING CONDITIONS

Coils for HACE throttling reheat terminals are available


in one (1) or two (2) rows. Data is based on 200f entering water temperature (EWT) and 75 entering air
temperature (eat)For other conditions, use the correction tables or formulas at the bottom of this page
as necessary. GPM below 0.5 is not recommended because it produces laminar flow. Standard coils are not
recommended for steam.

HACE hot water heating coils for throttling reheat


VAV terminals are constructed of 1/2 O.D SEAMLESS
COPPER TUBING. 0.016 thick. The core is entirely
of straight tube construction and the casing is fabricated from 20 gauge galvanized steel. Coils have 10
aluminum corrugated fins per inch, 0.006 thick. Tube
headers are extended for 5/8 or 7/8 O.D field sweat
connection.

COIL DISCHARGE
CONNECTIONS

MODELS
S

MSR

A, B

A, B

C, D

C, D

NUMBER OF CIRCUITS

COIL
CONN O.D

CFM RANGE

1 ROW

2 ROW

10

5/8

100 - 600

10

12

5/8

200 - 1000

10

14

5/8

400 - 1500

10

17

5/8

200 - 2000

10

22

5/8

400 - 3000

10

27

5/8

400 - 4000

10

36

5/8

1500 - 5000

18

27

7/8

1000 - 7000

18

36

7/8

4000 - 10,000

B, C, D
E, F
G

Temperature (Degrees F) Difference Correction Factor


Tempreture
Difference
Correction
Factor

p a g e

22

60

70

80

90

100

110

120

130

140

150

0.48

0.56

0.64

0.72

0.80

0.88

0.96

1.04

1.12

1.20

GPM

Gallons Per Minute

MBH

1,000 BTUH (British Thermal Units/Hour)

EWT

Entering Water Temperature F

EAT

Entering Air Temperature F

HOT WATER HEATING COIL OPTION

HOT WATER HEATING PERFORMANCE

1 Row, 1 CIRCUIT, 10 x9

1 Row, 1 CIRCUIT, 10 x9
1.0

1.5

0.33

0.67

5,669
6,879
7,788
8,518
9,130
9,657
10,120
10,533
10,906
11,247
11,559

5,896
7,221
8,233
9,056
9,753
10,359
10,895
11,377
11,815
12,217
12,588

BTUH
(Thousands)

CFM

100
150
200
250
300
350
400
450
500
550
600

2 Row, 1 CIRCUIT, 10 x9

1.0

1.5

0.68

1.38

BTUH
(Thousands)

100
150
200
250
300
350
400
450
500
550
600

9,068
11,572
13,479
15,009
16,283
17,371
18,317
19,154
19,903
20,580
21,197

9,442
12,212
14,373
19,142
17,638
18,933
20,074
21,094
22,015
22,856
23,627

CFM
0.39
200
300
400
500
600
700
800
900
1,000

BTUH
(Thousands)

2.25
6,155
7,619
8,757
9,698
10,504
11,211
11,844
12,417
12,943
13,428
13,879

GPM
2.0
2.5
HEAD LOSS FEET
2.28
3.37
BTUH
9,644
9,770
12,563
12,786
14,871
15,190
16,780
17,192
18,409
18,910
19,830
20,417
21,092
21,759
22,225
22,971
23,256
24,076
24,200
25,091
25,071
26,032

3.0
4.64
9,857
12,941
15,413
17,481
19,263
20,831
22,232
23,501
24,660
25,729
26,720

1 Row, 1 CIRCUIT, 10 x 12
1.0

3.0

2 Row, 1 CIRCUIT, 10 x9

CFM

1 Row, 1 CIRCUIT, 10 x 12

GPM
2.0
2.5
HEAD LOSS FEET
1.11
1.64
BTUH
6,020
6,099
7,411
7,533
8,483
8,644
9,361
9,559
10,108
10,340
10,761
11,025
11.342
11,636
11,866
12,188
12,344
12,694
12,784
13,160
13,192
13,593

8,961
10,595
11,797
12,750
13,540
14,214
14,803
15,324
15,793

GPM
3.0
4.0
HEAD LOSS FEET
1.31
2.67
4.41
BTUH
9,761
10,073
10,242
11,745
12,205
12,456
13,252
13,843
14,169
14,475
15,186
15,580
15,509
16,330
16,787
16,407
17,331
17,847
17,202
18,222
18,795
17,917
19,028
19,654
18,567
19,764
20,442
2.0

5.0
6.52
10,349
12,616
14,376
15,832
17,081
18,180
19,165
20,059
20,881

p a g e

23

HOT WATER HEATING COIL OPTION

HOT WATER HEATING PERFORMANCE

2 Row, 1 CIRCUIT, 10 x 12

2 Row,1 CIRCUIT, 10 x 12
GPM
1.0

2.0

CFM

3.0

4.0

5.0

9.06

13.39

HEAD LOSS FEET


0.80

2.69

5.48

BTUH
(Thousands)

BTUH

1 Row, 1 CIRCUIT, 10 x 14

200

14,885

16,438

17,034

17,353

17,552

300

18,204

20,652

21,626

22,154

22,487

400

20,610

23,865

25,193

25,921

26,383

500

22,479

26,458

28,116

29,034

29,619

600

23,996

28,633

30,599

31,695

32,397

700

25,265

30,504

32,758

34,023

34,838

800

26,353

32,146

34,671

36,097

37,018

900

27,300

33,608

36,390

37,969

38,992

1,000

28,138

34,926

37,950

39,676

40,798

1 Row, 1 CIRCUIT, 10 x 14
1.0

2.0

0.43

1.45

12,756
13,808
14,679
15,421
16,067
16,639
17,153
17,618
18,044
18,435
18,798
19,136

14,356
15,713
16,860
18,856
18,737
19,528
20,247
20,906
21,515
22,081
22,611
23,108

BTUH
(Thousands)

CFM

400
500
600
700
800
900
1,000
1,100
1,200
1,300
1,400
1,500

2 Row, 1 CIRCUIT, 10 x 14

CFM
0.88

BTUH
(Thousands)

400
500
600
700
800
900
1,000
1,100
1,200
1,300
1,400
1,500

24

4.0

5.0

4.87

7.20

15,358
16,927
18,270
19,449
20,502
21,457
22,331
23,138
23,890
24,593
25,254
25,879

15,584
17,203
18,592
19,815
20,910
21,904
22,817
23,661
24,448
25,185
25,880
26,537

2 Row, 1 CIRCUIT, 10 x 14
1.0

p a g e

GPM
3.0
HEAD LOSS FEET
2.95
BTUH
15,003
16,495
17,767
18,878
19,868
20,762
21,579
22,332
23,030
23,682
24,294
24,870

21,836
23,865
25,507
26,878
28,048
29,064
29,961
30,759
31,478
32,130
32,726
33,273

GPM
4.0
6.0
HEAD LOSS FEET
2.97
9.98
20.30
BTUH
25,371
27,596
28,439
28,218
31,027
32,106
30,605
33,964
35,268
32,656
36,534
38,055
34,455
38,824
40,552
36,054
40,889
42,817
37,494
42,773
44,893
38,802
44,505
46,180
40,000
46,109
48,594
41,105
47,604
50,262
42,129
49,004
51,830
43,084
50,320
53,310
2.0

8.0
33.58
28,886
32,681
35,967
38,874
41,486
43,863
46,047
48,069
49,954
51,721
53,385
54,958

HOT WATER HEATING COIL OPTION

HOT WATER COIL PERFORMANCE

1 Row, 1 CIRCUIT, 10 x 17

1 Row, 1 CIRCUIT, 10 x 17
1.0
CFM
0.49

BTUH
(Thousands)

200
400
600
800
1,000
1,200
1,400
1,600
1,800
2,000

2 Row, 1 CIRCUIT, 10 x 17

10,461
14,015
16,182
17,738
18,951
19,942
20,778
21,500
22,136
22,702

CFM
1.00

BTUH
(Thousands)

200
400
600
800
1,000
1,200
1,400
1,600
1,800
2,000

16,463
23,354
27,397
30,171
32,242
33,871
35,201
36,316
37,269
38,098

GPM
4.0
6.0
HEAD LOSS FEET
3.38
11.37
23.11
BTUH
18,207
19,220
19,586
27,264
29,713
30,637
33,122
36,890
38,348
37,425
42,378
44,333
40,811
46,836
49,252
43,594
50,599
53,446
45,949
53,859
57,111
47,988
56,737
60,372
49,782
59,315
63,314
51,381
61,652
65,997
2.0

1.0

400
600
800
1,000
1,200
1,400
1,600
1,800
2,000
2,200
2,400
2,600
2,800
3,000

BTUH
(Thousands)

8.22
12,095
17,195
20,631
23,278
25,453
27,313
28,944
30,401
31,722
32,931

8.0
38.23
19,777
31,125
39,128
45,387
50,565
55,002
58,898
62,378
65,530
68,414

1 Row, 1 CIRCUIT, 10 x 22
2.0

CFM

5.0

2 Row, 1 CIRCUIT, 10 x 17
1.0

1 Row, 1 CIRCUIT, 10 x 22

GPM
3.0
4.0
HEAD LOSS FEET
1.65
3.36
5.57
BTUH
11,410
11,776
11,972
15,820
16,546
16,943
18,668
19,698
20,267
20,798
22,091
22,814
23,509
24,038
24,898
23,942
25,686
26,673
25,179
27,210
28,225
26,267
28,392
29,609
27,240
29,537
30,858
28,121
30,580
32,000
2.0

0.59

2.00

15,757
18,277
20,073
21,462
22,591
23,538
24,352
25,064
25,696
26,264
26,778
27,247
27,679
28,077

17,876
21,240
23,748
25,755
27,433
28,875
30,142
31,271
32,291
33,220
34,074
34,864
35,599
36,286

GPM
3.0
HEAD LOSS FEET
4.06
BTUH
18,725
22,462
25,298
27,599
29,544
31,232
32,728
34,072
35,294
36,415
37,451
38,415
39,317
40,164

4.0

5.0

6.72

9.93

19,186
23,136
26,161
28,634
30,737
32,573
34,207
35,681
37,027
38,266
39,415
40,488
41,493
42,441

19,478
23,566
26,714
29,300
31,508
33,442
35,169
36,731
38,161
39,480
40,706
41,853
42,930
43,947

p a g e

25

HOT WATER HEATING COIL OPTION

HOT WATER COIL PERFORMANCE

2 Row, 1 CIRCUIT, 10 x 22

2 Row, 1 CIRCUIT, 10 x 22
1.0

2.0

24,315
28,464
31,252
33,297
34,885
36,165
37,227
38,128
38,906
39,586
40,187
40,725
41,209
41,649

28,934
35,250
39,831
43,392
46,287
48,715
50,797
52,615
54,224
55,665
56,967
58,152
59,240
60,242

CFM

BTUH
(Thousands)

400
600
800
1,000
1,200
1,400
1,600
1,800
2,000
2,200
2,400
2,600
2,800
3,000

GPM
4.0
HEAD LOSS FEET
BTUH
31,941
39,946
46,036
50,952
55,074
58,623
61,738
64,514
67,017
69,296
71,387
73,319
75,113
76,789

6.0

8.0

33,101
41,819
48,574
54,106
58,802
62,888
66,508
69,761
72,716
75,425
77,926
80,251
82,423
84,462

33,722
42,836
49,967
55,854
60,883
65,284
69,204
72,742
75,969
78,939
81,692
84,258
86,663
88,927

CFM

1 Row, 1 CIRCUIT, 10 x 27

1 Row, 1 CIRCUIT, 10 x 27
1.0
CFM
0.10

BTUH
(Thousands)

400
800
1,200
1,600
2,000
2,400
2,800
3,200
3,600
4,000

16,311
20,586
23,001
24,656
25,900
26,890
27,706
28,398
28,996
29,521

GPM
2.0
3.0
4.0
HEAD LOSS FEET
0.34 0.69
1.13
BTUH
18,920 20,011 20,617
25,053 27,042 28,181
28,811 31,500 33,069
31,527 34,798 36,733
33,653 37,425 39,682
35,398 39,614 42,160
36,877 41,492 44,301
38,159 43,138 46,190
39,290 44,604 47,881
40,301 45,925 49,413

5.0
1.68
21,005
28,923
34,103
38,019
41,193
43,874
46,202
48,264
50,118
51,803

CFM

2 Row, 1 CIRCUIT, 10 x 27

2 Row, 1 CIRCUIT, 10 x 27
1.0
CFM

BTUH
(Thousands)

0.21

CFM

p a g e

26

400
800
1,200
1,600
2,000
2,400
2,800
3,200
3,600
4,000

25,863
33,493
37,409
39,886
41,633
42,948
43,984
44,827
45,530
46,128

GPM
4.0
6.0
8.0
HEAD LOSS FEET
0.70 2.34
4.76
7.87
BTUH
30,877 34,113 35,351 36,011
43,096 50,031 52,855 54,399
50,302 60,273 64,495 66,846
55,296 67,811 73,266 76,344
59,061 73,764 80,322 84,063
62,053 78,676 86,235 90,585
64,517 82,852 91,328 96,243
66,598 86,479 95,803 101,248
68,392 89,683 99,797 105,740
69,962 92,550 103,404 109,817
2.0

HOT WATER HEATING COIL OPTION

HOT WATER COIL OPTION PERFORMANCE

2 Row, 1 CIRCUIT, 17.5 x 27

2 Row, 1 CIRCUIT, 17.5 x 27

1.0
CFM
0.12

BTUH
(Thousands)

1,000
1,500
2,000
2,500
3,000
3,500
4,000
4,500
5,000
5,500
6,000
6,500
7,000

40,536
44,432
46,708
48,217
49,298
50,115
50,757
51,275
51,705
52,066
52,376
52,644
52,879

GPM
4.0
6.0
HEAD LOSS FEET
0.40
1.34
2.72
BTUH
55,606
67,355
72,324
64,292
81,189
88,718
70,028
91,120
100,883
74,184
98,789
110,525
77,377
104,992
118,491
79,930
110,172
125,266
82,033
114,600
131,152
83,805
118,454
136,347
85,324
121,856
140,993
86,645
124,895
145,190
87,808
127,634
149,014
88,843
130,123
152,524
89,771
132,401
155,765
2.0

8.0
4.50
75,082
92,998
106,534
117,415
126,514
134,330
141,181
147,278
152,769
157,762
162,341
166,566
170,490

CFM

1 Row, 1 CIRCUIT, 17.5 x 36

1 Row, 1 CIRCUIT, 17.5 x 36


1.0

2.0

0.07

0.25

38,935
39,523
40,026
40,464
40,850
41,193
41,501
41,779
42,032
42,264
42,477
42,674
42,857

57,665
59,125
60,408
61,548
62,573
63,501
64,348
65,126
65,844
66,510
67,130
67,710
68,254

CFM

BTUH
(Thousands)

4,000
4,500
5,000
5,500
6,000
6,500
7,000
7,500
8,000
8,500
9,000
9,500
10,000

GPM
3.0
HEAD LOSS FEET
0.51
BTUH
68,213
70,330
72,213
73,906
75,442
76,847
78,141
79,338
80,452
81,492
82,468
83,386
84,252

4.0

5.0

0.85

1.25

74,987
77,585
79,914
82,022
83,948
85,719
87,358
88,883
90,308
91,645
92,904
94,094
95,221

79,717
82,679
85,347
87,774
90,000
92,055
93,946
95,746
97,417
98,990
100,475
101,882
103,219

CFM

2 Row, 1 CIRCUIT, 17.5 x 36

2 Row, 1 CIRCUIT, 17.5 x 36


2.0
CFM
0.23

BTUH
(Thousands)

4,000
4,500
5,000
5,500
6,000
6,500
7,000
7,500
8,000
8,500
9,000
9,500
10,000

87,123
88,859
90,332
91,600
92,706
93,681
94,549
95,327
96,030
96,669
97,253
97,788
98,282

GPM
6.0
8.0
HEAD LOSS FEET
0.77
1.56
2.58
BTUH
125,392
145,555
157,988
129,516
151,318
164,888
133,129
156,443
171,075
136,333
161,049
176,679
139,204
165,227
181,796
141,797
169,043
186,502
144,157
172,552
190,856
146,317
175,796
194,904
148,307
178,810
198,685
150,146
181,622
202,231
151,856
184,255
205,568
153,450
186,730
208,718
154,941
189,063
211,700
4.0

10.0
3.81
166,437
174,162
181,127
187,467
193,283
198,656
203,645
208,303
212,668
216,776
220,654
224,326
227,812

CFM

p a g e

27

Arrangement Codes for (S & MSR Models)

Standard Outlet Arrangement Codes

1. Air inlet of unit is shown at top of outlet arrangement drawings.


2. Air outlet code is determined by the following: QTY. Left outlets -QTY. End outlets- QTY. right outlets. Code 000 is drive outlet

Minimum Dimensions All Outlets Arrangements


(Arrangement shows code 121

Typical Extended Plenum Arrangement Codes

Maximum size and quantity of discharge outlets on units and or extended plenums is determined by following
calculations:
A) Find the desired round outlet diameter or the oval dimension h x w from the outlet dimension table below for your
required outlets.
B) Add 2 to the round diameter or oval dimension width.
C) Multiply the result by the number of outlets required on 1 surface.
D) The result must be less than or equal to the available unit length (side outlets) or width (end outlets). Available unit
length without extended plenum is found by subtracting 12 from the standard unit length. Available unit width is the
full unit width. If side outlets chosen exceed the dimensions allowed, an extended plenum is required. Extended plenums
are available in 1 foot increments to a maximum of 4 feet.
E) The outlet diameter or oval dimension height, plus 2 must be less than or equal to the unit height.
Note:
If unit has optional control panel, side outlets on unit control panel side is not allowed without extended plenum.

Nom. size
Round dia.
Oval dim. H xW
Nom. size
Round dia.
Oval dim. H x W

p a g e

28

5
4.88
3.88 x 5.45
14
N/A
7.88 x 17.30

6
5.88
3.88 x 7.03
16
N/A
7.88 x 20.44

Outlet dimensions
7
8
6.88
7.88
5.88 x 7.45
N/a
18
20
N/A
N/A
7.88 x 23.58
7.88 x 26.87

9
N/a
7.88 x 9.45
22
N/A
7.88 x 29.87

10
N/a
7.88 x11.02
24
N/A
7.88 x 33.01

12
N/a
7.88 x 14.16
26
N/A
7.88 x 36.15

Products Range

Contact us
FACTORY
T| 966 11 265 1500
F| 966 11 265 1521
@|mkt@hace.com.sa
RIYADH OFFICE
T| 966 11 478 5147 - 477 2515
F| 966 11 477 1740
@|riyadh@hace.com.sa
AL - KHOBAR OFFICE
T| 966 13 894 3337
F| 966 13 894 1478
@|hace.kho@hace.com.sa
JEDDAH OFFICE
T| 966 12 665 5595
F| 966 12 665 5642
@|hace.jed@hace.com.sa
AMMAN OFFICE
T| 962 6 554 0353
F| 962 6 554 0352
@|hace.jordan@hace.com.sa

www.hace.com.sa
R-1311