ENERGY MANAGERS AND ENERGY AUDITORS
PAPER 3 : ENERGY EFFICIENCY IN ELECTRICAL UTILITIES
Duration: 3 Hrs.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
The overall efficiency for the coal based power plants in India ranges from -- %
a) 40 to 50 b) 52-65 c) 28-35 d) 15-25
The standard technical losses in India are around - %
a) 17 b) 23 c) 27 d) 50
The designed power transformers efficiency is in the range of
a) 96-99 % b) 80-90% c) 90-95.5% d) 92.5- 93.5%
The primary purpose of a Capacitor is to reduce
a) power factor b) maximum demand c) voltage d) none
A.C. Motors are
a) capacitive loads b) inductive loads c) resistive loads d) none of the above
For a given mains frequency of 50Hz and number of poles being 6, its synchronous speed is
--- rpm.
a) 3000 b) 1500 c) 1000 d) 375
The actual value of stray losses of motors up to 200 HP is likely to be -- %
a) 0.5 b) 1-3 c) 5 d) 7.5
AC induction motor is a --- motor
a) synchronous b) asynchronous c) highly expensive d) none of the above
An induction motor with 4 poles operating at 50Hz, has a slip of 2%. Its actual speed will be
--- rpm.
a) 1485 b) 1500 c) 1470 d) 1440
According to BIS standards, a motor will deliver its rated output, if --a) voltage variation is 6% and frequency variation of 3%
b) voltage variation is 10% and frequency variation is 5%
c) voltage variation is 12% and frequency variation is 7%
d) none of the above
The volumetric efficiency of a compressor --- with increase in altitude of place, where the
compressor is installed
a) increases b) decreases c) does not change d) none of the above
The percentage increase in power consumption of a compressor with suction side air filter and
with pressure drop across the filter of 200 mm Wc is -- %
a) 1 b) 3 c) 2.4 d) 1.6
The compressor capacity of a reciprocating type is directly proportional to --a) pressure b) volume c) speed d) all
Which of the parameter indicated below is not required to evaluate the volumetric efficiency
of the compressor?
a) FAD b) stroke length c) power d) cylinder bore diameter
Multi-step control is employed for --- compressors
a) medium b) large c) small d) none
COP of absorption refrigeration system is --a) between 4 -- 5 b) less than 1.1 c) above 1.1 d) always around 2.75
For a living room of 12 feet x 12 feet at residence, the required A/C size for comfort-
40.
41.
42.
43.
44.
45.
46.
47.
48.
49.
50.
Section ii
(i)
(ii)
5. Why variable torque loads offer greatest energy savings? Explain electronic methods of
speed controllers.