Professional Documents
Culture Documents
Terumo
Terufusion Infusion Pump
TE-171/TE-172
MIDPRESS system
Tube doesn't open
completely.
Tube is pressed
halfway to closure.
D
E
Inflow
Inflow stops
Outflow
Outflow
Outflow stops
Pulse flow
A certain
outflow starts as
outflow continues
adjustment
amount of solution
as part C presses
tube fully.
Part e presses
D is closed.
accumulates in
the tube.
tube.
presses against
the tube.
High accuracy
High flow rate accuracy is achieved: within 3% using the specified
TeruFuSIoN infusion sets type e and within 5% using conventional
TeruFuSIoN infusion sets.
The mIDPreSS method succeeds in minimizing flow rate changes
even over long periods, particularly for the delivery of vasopressor
or depressor drugs.
Wide range of flow rate settings is possible, from very low to high
Flow rates can be set within a wide range (from 0.1 mL/h to 1,200
mL/h). This makes it possible to perform infusions in a wide variety
of situations and applications, such as small infusions for neonates,
rapid infusion for emergency care and the delivery of parenteral
nutrition.
Transfusion
Since the mIDPreSS system doesn't flatten the tube completely,
damage to hemocytes is reduced. This means that the Te-171/Te-172
can be used for blood transfusions in pediatric or ICu cases with the
specified SAFeeD extension tube for pumps.
The
TERUFUSION
Infusion
Pump
TE171/TE172 has a revolutionary
MIDPRESS system that provides highly
accurate infusions. With other user
friendly and advanced safety features,
the TE171/TE172 fully meets the
demands of modern infusion therapy.
History function
Historical data of infusion records: warnings, settings, starts
and stops of infusion, etc.
connection
enables
connection
to
Specifications
Product name and model
Special functions
Keep vein open function (After the delivery limit has been reached,
delivery continues at 1 mL/h for a set flow rate of 1mL/h: or at the delivery
rate setting < 1 mL/h.)
Tubing clamp function (When the door is opened, tubing is automaticallly
clamped.)
Volume delivered clear function
Time remaining display
Battery capacity indicator (3 levels)
Adjustable display brightness (Can be switched to 2 levels)
Adjustable buzzer volume (3 levels)
operation history function (Storage/display of operation history)
Standby function
repeat alarm function
Start reminder function
The following functions can be selected via internal switches:
Volume memory function
Delivery rate 1 mL/h step
Operating conditions
Temperature: +5 to +40 C, humidity: 20 to 90%
Delivery limit
Storage conditions
Volume delivered
Power supply
0.0 9,999 mL (0.0 99.9 mL: 0.1 mL step, 100 9,999 mL: 1 mL step).
The volume delivered reading is in 1 mL step from 1 to 9,999 mL by the internal
mode select switch.
Purging
Higher than 500 mL/h
Alarms
AIr/oCCLuSIoN/FLoW err./Door/LoW BATT.
* operation indicator flashes red, and the alarm message comes on.
Pump stops except during the LoW BATT. alarm.
Power consumption
28 VA (AC 100 240 V), 11 W (DC power)
Classification
Class I & internal power supply: Type CF/IPX1 Continuous operation
Occlusion detection
Dimensions
Pressure
Weight
The detection pressure can be adjusted in 3 levels (L, m, H) within the above
range.
Completion function
TE172
When the total volume delivered reaches the preset delivery limit, the
indicator and buzzer notify the operator.
outputs an alarm relay contact. (Can be connected to the nurse call system)
Contact rating: DC12 V 1.0 A
Computer interface*
Memory function
rS-232C/rS-485
The latest five patterns of the above four parameters are automatically saved
and can be displayed.
Every day,
as healthcare
professionals,
you are working
to ensure life and
to contribute
to the well-being
of your patients.
Every day,
Terumo Europe
provides you
with the clinical
systems, means
and solutions
to keep life flowing.
TERUMO
CORPORATION
44-1, 2-chome
Hatagaya
Shibuya-ku
Tokyo 151-0072
JAPAN
Tel. +81/3 3374.8111
Fax +81/3 3374.8196
TERUMO EUROPE N.V.
Researchpark Zone 2
Haasrode
Interleuvenlaan 40
B-3001 Leuven
BELGIUM
Tel. +32/16.38.12.11
Fax +32/16.40.02.49
TERUMO EUROPE N.V.
BENELUX SALES
DIVISION
Researchpark Zone 2
Haasrode
Interleuvenlaan 40
B-3001 Leuven
BELGIUM
Tel. +32/16.39.25.80
Fax +32/16.39.25.99
THE NETHERLANDS
Tel. 0800/022.03.96
Fax 0800/022.04.14
LABORATOIRES
TERUMO
FRANCE S.A.
1, Parc Ariane
Btiment Uranus
Rue Hlne Boucher
78284 Guyancourt Cedex
FRANCE
Tel. +33/1 30.96.13.00
Fax +33/1 30.43.60.85
TERUMO
DEUTSCHLAND GmbH
Hauptstrasse 87
65760 Eschborn
GERMANY
Tel. +49/61.96.80.230
Fax +49/61.96.80.23.200
TERUMO
DEUTSCHLAND GmbH
Zweigniederlassung
Wettingen
Bahnhofstrasse 88
CH-5430 Wettingen
SWITZERLAND
Tel. +41/56.419.10.10
Fax +41/56.419.10.11
TERUMO EUROPE
ESPAA SL
Avda. Juan Carlos I,
N 13 - 7 Planta
Edificio Torre La Garena
28806 Alcal de Henares
(Madrid)
SPAIN
Tel. general:
+34/902.10.12.98
Tel. cust. serv.:
+34/902.20.31.40
Fax general:
+34/902.10.13.58
Fax cust. serv.:
+34/902.10.17.57
TERUMO ITALIA SRL
Via Simone Martini
143/145
I-00142 Roma
ITALY
Tel. +39/06.519.61.420
Fax +39/06.503.04.07
TERUMO SWEDEN AB
Nya Varvet, Byggnad 90
Sven Kllfelts Gata 18
SE-426 71 Vstra
Frlunda
SWEDEN
Tel. +46/31.748.58.80
Fax +46/31.748.58.90
www.terumo.com
www.terumo-europe.com
TERUMO DENMARK
Filial af TERUMO
SWEDEN AB
Tel. +45/7020.93.80
Fax +45/7020.94.80
TERUMO UK Ltd.
Tamesis
The Causeway
Egham
Surrey
TW20 9AW
UNITED KINGDOM
Tel. +44/1784.476.200
Fax +44/1784.476.201
TERUMO EUROPE N.V.
Moscow Representative
office
4, Ivana Franko St
121108 Moscow
RUSSIA
Tel. +7/495.234.3303
Fax. +7/495.234.3303
: Registered Trademark
Published by Terumo
Europe N.V.
HO 79GB-0504NEL-III1(10.08)E
Pumping system