You are on page 1of 13

Steel wall-mounting enclosures

Spacial S3D

Accessories

PB500454-43

PB501821-18

PB500339

Fixing

PB500453-37

800 mm

[PP

Characteristics Support pillar

7KHVXSSRUWSLOODULV[HGGLUHFWO\WRWKH
bottom face of the Spacial steel
enclosure by means of an adapter plate.
The latter, to be ordered in addition to the
pillar, replaces the cable-gland plate.
2YHUDOOKHLJKWRIWKHVXSSRUWIRRWPP
0RXQWLQJSRVVLEOHRQDOOHQFORVXUHVZLWK
GLPHQVLRQVXSWR[[PP
H[FHSW[[DQG[[
150 enclosures).

Support bracket for


enclosure with anti-tilt kit
and reinforcement

Floor Stand Kit for wall-mounting


enclosure
6HWRIIHHWHOHYDWLQJZDOOPRXQWLQJHQFORVXUHV
Cut-outs needed on enclosure drilling template
SURYLGHGZLWKWKHNLW

Material
Finish
Colour
Thickness

([WUXGHGDOXPLQLXP
3RO\HVWHUSRZGHU
RAL 7035 grey
-

The support bracket for Spacial S3D and


Spacial CRN steel enclosures is used
ZKHQWKHHQFORVXUHFDQQRWEHKXQJIURP
DZDOORUDSRVW
Suitable for outdoor use.
&RPSDWLEOHZLWKRWKHUHQFORVXUHUDQJHV
b S3X (stainless-steel),
b 6+) (0& 
b Thalassa (polyester).
0D[LPXPHQFORVXUHGLPHQVLRQV
[[PP
Floor attachment by standard M12
fastenings.
Steel
Painted
RAL 7035 grey
-

0D[LPXPORDG
Supply

120 kg
-

Steel
3RO\HVWHUSRZGHU
RAL 7035 grey
b 6LGHVPP
b %DVHPP
250 kg
SODWIRUPIHHW ULJKWDQGOHIW DQG[LQJHOHPHQWV

Reference

References

Enclosure depth Foot height

Height (mm)

mm
NSYCOCN80
-

NSYCOCNS1400
NSYCOCNS1800
-

55

50
160
250

798

DB300084-22

800
1400
1800
-

75
330
370

Support pillar adaptation plate


PB500331-21

Description: SODWHIRU[LQJWKHVXSSRUW
pillar on the enclosure.
This plate replaces the cable-gland plate
GHOLYHUHGZLWKWKHHQFORVXUH
Material: steel
Finish:SRO\HVWHUSRZGHU
Colour: RAL 7035 grey

For enclosure (mm) References


Width
300-400
300
400

60

Depth
150
200
200-250

NSYAEFP315S3D
NSYAEFP32S3D
NSYAEFP42S3D

Inches

mm

References

Inches

300*
12
300
12
NSYWMK33
400**
16
300
12
NSYWMK43
300*
12
450
18
NSYWMK34
400**
16
450
18
NSYWMK44
* When enclosures are equipped with a cable gland
SODWHLWRQO\WVZLWKHQFORVXUHVRIZLGWK 
1200 mm, except model H 600 x W 800 x D 300 mm.
** When enclosures are equipped with a cable gland
SODWHLWGRHVQRWWZLWKHQFORVXUHVRIZLGWKPP
&RPSDWLEOHZLWK6SDFLDO6'6'& &51*
enclosures.

Steel wall-mounting enclosures

Spacial S3D

Accessories

Floor

Material
Finish
Colour
Ingress protection rating
Mechanical protection rating
Installation
Supply

PB502580-17
PB502579-30

PB502578-30

Characteristics

PB502581-18

For more information, see page 98.

Front and rear plinth

Plinth side panels

7KHIURQWDQGUHDURIWKHSOLQWKFRQVLVWVRIFRUQHUVZLWK
7KH\DUH[HGWRWKHFRUQHURIWKHSOLQWKE\[LQJVFUHZV
2 or 4 panels.
)ROGHGVKHHWVWHHOFRUQHUZLWKDWKLFNQHVVRIPP
Folded sheet steel
3DLQWHGZLWKHSR[\SRO\HVWHUUHVLQ
3DLQWHGZLWKHSR[\SRO\HVWHUUHVLQ
RAL 7022 grey
RAL 7022 grey
IP30
IP30
IK10
IK10
,WLVQHFHVVDU\WRRUGHUVHSDUDWHO\WKHSOLQWK[LQJNLW UHINSYAPFWM FRPSRVHGE\[LQJKDUGZDUHDQGGULOOLQJMLJ
b +HLJKWPPFRUQHUVSDQHOV IURQWDQGUHDU 
b +HLJKWPPVLGHSDQHOVFRUQHUFRYHUVDQG[LQJ
FRUQHUFRYHUVDQG[LQJHOHPHQWV
elements
b +HLJKWPPFRUQHUVSDQHOV IURQWDQGUHDU 
b +HLJKWPPVLGHSDQHOV KHLJKWRIPP
FRUQHUFRYHUVDQG[LQJHOHPHQWV
IRUHDFKVLGH FRUQHUFRYHUVDQG[LQJHOHPHQWV

References
NSYSPF6100
NSYSPF8100
NSYSPF10100
NSYSPF12100
-

Characteristics

800
1000
1200

800
800
1000
800
1000

200 mm
NSYSPS3200SD
NSYSPS4200SD

Plinth height 100 mm


(Set of 2 side panels)

Plinth height 200 mm


(4 corners + front and back)

Plinth height 200 mm


(Set of 2 side panels)

Stainless-steel plinths
Stainless-steel, AISI 304L
Stainless-steel, AISI 316L
Scotch-BriteEUXVKLQJWRJXDUDQWHHWKHGXUDELOLW\LQDSSOLFDWLRQZKHUHWKHFRQWDFWZLWKWKHRRULQFUHDVHWKHULVNRIFRUURVLRQ
,WLVQHFHVVDU\WRRUGHUVHSDUDWHO\WKHSOLQWK[LQJNLW UHI16<$3);:0 FRPSRVHGE\[LQJKDUGZDUHDQGGULOOLQJMLJ

External dimensions (mm) Plinth height 100 mm


Height Width
(A)
(B)

100 mm
NSYSPS3100SD
NSYSPS4100SD

PB502590-30

PB502589-30

Plinth height 100 mm


(4 corners + front and back)

Material
Finish
Installation

200 mm
NSYSPF6200
NSYSPF8200
NSYSPF10200
NSYSPF12200
-

PB502592-21

Depth (mm) 100 mm


300
400

PB502591-18

Width (mm)
600
800
1000
1200
-

Plinth height 200 mm

Plinth height 100 mm

Plinth height 200 mm

Depth
(C)

Kit (4 corners + Set of 2 side


front and back) panels

Kit (4 corners + Set of 2 side


front and back) panels (x2)

Kit (4 corners + Set of


front and back) 2 side panels

Kit (4 corners + Set of 2 side


front and back) panels (x2)

300
300
300
300
300

16<63);
16<63);
16<63);
16<63);
16<63);

16<63);
16<63);
16<63);
16<63);
16<63);

16<63);+
16<63);+
16<63);+
16<63);+
16<63);+

16<63);+
16<63);+
16<63);+
16<63);+
16<63);+

16<636;
16<636;
16<636;
16<636;
16<636;

16<636;
16<636;
16<636;
16<636;
16<636;

16<636;+
16<636;+
16<636;+
16<636;+
16<636;+

16<636;+
16<636;+
16<636;+
16<636;+
16<636;+

61

Steel wall-mounting enclosures

Spacial S3D

Accessories

PB500335-62

PB500336-34

Coupling

PB500337-26

Version without cable entry.

Installation example.

Characteristics

Material
Ingress protection rating
Supply

Version with cable entry.

Coupling of Spacial steel enclosures


$YDLODEOHLQYHUVLRQV
b &RXSOLQJYHUVLRQZLWKRXWFDEOHHQWU\
b 9HUVLRQZLWKFRXSOLQJIUDPHDOORZLQJWKHHQWU\RIFDEOHV
b 6HSDUDWLRQRIPPEHWZHHQFRXSOHGHQFORVXUHV
DOORZLQJIXOORSHQLQJRIWKHGRRUV
$OORZVODWHUDOFRXSOLQJRIHQFORVXUHV
7KHVHIUDPHVDOORZWKHGRRUWRRSHQWR
3RO\HVWHUFKDUJHGZLWKEUHJODVVVHOIH[WLQJXLVKLQJ
IP66
b .LWPDGHXSRIVSDFHUVDQGWKHLU[LQJV
b 0RXQWLQJE\VFUHZVLQFOXGHG

References

DB300078-27

NSYAEUBUSC
NSYAEUBU41SC
NSYAEUBU61SC
DB300077-27

Batch of 4 coupling spacers


&RXSOLQJIUDPH[PP
&RXSOLQJIUDPH[PP

Version without cable entry.

399/599***

DB300079-37

Version with
cable entry.

14

.5
19

62

25

Steel wall-mounting enclosures

Spacial S3D

Accessories

PB500338-29

Hoisting

Characteristics

6HWRIWZR0H\HEROWV7KH\DUH[HGGLUHFWO\WRWKHERG\RIWKHRRUVWDQGLQJHQFORVXUH&DQQRWEHLQVWDOOHGZLWKWKHFDQRS\LQSODFH
Zinc-coated moulded steel
NJSHUHQFORVXUHZKHQVOLQJLQJDW
Reinforcing brackets attached to the rings (these brackets also act as a drilling template)
NSYAELYTCRG8
DB300081-20

Material
0D[LPXPORDG
Supply
Reference
Batch of 2 M8 eyebolts

Eyebolts

PB500329-40

Protection

DB300083-21

'LUHFW[LQJWRWKHERG\RIWKHHQFORVXUHE\0VFUHZV7REHXVHGIRUDOORXWGRRULQVWDOODWLRQV
Sheet steel
3DLQWHGJDOYDQLVHGVWHHOVWUXFWXUHGQLVK
RAL 7035 grey
'HOLYHUHGZLWKWKH[LQJVUHTXLUHGIRULQVWDOODWLRQ
F (mm)
G (mm) H (mm)
References
36
75
23
NSYTJ2015
36
75
23
NSYTJ2515
36
75
23
NSYTJ3015
36
75
23
NSYTJ4015
36
75
23
NSYTJ5015
36
130
23
NSYTJ5020
36
130
23
NSYTJ6020
36
130
23
NSYTJ2520
36
130
23
NSYTJ3020
36
130
23
NSYTJ4020
36
130
23
NSYTJ8020
42
150
48
NSYTJ4025
42
150
48
NSYTJ5025
42
150
48
NSYTJ6025
42
150
48
NSYTJ8025
42
200
48
NSYTJ6030
42
200
48
NSYTJ8030
42
200
48
NSYTJ10030
42
200
48
NSYTJ12030
42
300
48
NSYTJ6040
42
300
48
NSYTJ8040
42
300
48
NSYTJ10040
42
300
48
NSYTJ12040

15

15
H

Material
Finish
Colour
Supply
Depth (mm) Width (mm)
150
200
250
300
400
500
200
500
600
250
300
400
800
250
400
500
600
800
300
600
800
1000
1200
400
600
800
1000
1200

Protection canopy

DB300082-29

Characteristics

H
G

3
12

63

Steel wall-mounting enclosures

Spacial S3D

Accessories

Characteristics

Supply

PB500347-35

PB500343-19

DB300179-9

PB500346-14

Handles

Standard handle

Standard handles with keys

Handle lock operated using


screwdriver insert

2SHUDWLQJKDQGOHGHOLYHUHGZLWK
the enclosure.
b It can be attached to the locking
V\VWHPE\PHDQVRID[LQJHOHPHQW
b It can also be used to loosen
the caps protecting the studs
ZKHQSDLQWLQJ

$WWUDFWLYHDQGHUJRQRPLFELPDWHULDO
handle.
b /DUJHUDQJHRIEDUUHOVFRYHULQJ
all the most common needs.
b 6WDQGDUGFDP VHHGLDJUDPDERYH 
b The installation of the standard handle
GRHVQRWUHTXLUHWKHHVFXWFKHRQ
WREHUHPRYHG
'HOLYHUHGZLWKNH\V

NSYAEDL1242S3D
NSYAEDL405S3D
NSYAEDL421S3D
NSYAEDL455S3D
NSYAEDL2331S3D
NSYAEDL2433S3D
NSYAEDL3113S3D
NSYAEDL3524S3D

NSYTSMLS3D
-

References
1242
405
421
455
2331A
2433A
3113A
3524E

64

Steel wall-mounting enclosures

Spacial S3D

Accessories

Characteristics

Material
Mechanical protection rating
Supply

PB500351-15

PB500350-16

PB500461-13

PB500460-13

PB500459-23

PB500345-21

PB500344-22

PB500352

Locks

Standard
locks

Other lock with Double lock


screwdriver
insert and
metal latch

Other locks
with keys

"Push-close"
locking system

Spacial S3D
ZDOOPRXQWLQJ
enclosures are
VXSSOLHGZLWKD
3 mm double-bar
lock as standard.
b 6SDUHORFN
order ref.
NSYAEDLS3DRL
(escutcheon + cam
ZDVKHU 
b Large range
of standardised
LQVHUWVFRYHULQJDOO
the most common
needs.
b Installation and
UHPRYDOZLWKD
VLQJOHVFUHZ

Easy mounting instead of the


standard lock.

Easy mounting
instead of the
standard lock.

'HOLYHUHGZLWK
1 plastic key

Zamack
'HOLYHUHGZLWKPPGRXEOHEDU
metal key

Metal cam supplied

The Spacial S3D


enclosures can be
transformed into pushclose enclosures.
b The push-close
enclosure is used in
YDULRXVDSSOLFDWLRQV
and fully meets the
security demands
of the market.
b Locking system
ZLWKDPP
push-close system
LQDFFRUGDQFHZLWK
CNOMO standards.
b This system
DOORZVWKHGRRU
to be closed and
locked by simply
pushing it.
b System made up
of a lock and a
closure plate.
b It is only installed
RQHQFORVXUHVZLWK
1 locking point
+PP 
b 2WKHUGLPHQVLRQV
contact us.
IP55
-

NSYAEDLEDF9S3D
NSYAEDLEDF13S3D
NSYAEDLEDF14S3D

NSYAEDLPSS3D
-

References
DIN half-cylinder Padlockable (2)
(1)
NSYAEDLS6S3D
NSYAEDLS7S3D
NSYAEDLS8S3D
NSYAEDLB3S3D
NSYAEDLB5S3D
NSYAEDLT6S3D
NSYAEDLT8S3D
-

NSYAEDLSDS3D
-

NSYAEDLDINS3D
-

NSYAEDLPADS3D
-

DB300095-38

PPVTXDUH
PPVTXDUH
PPVTXDUH
3 mm double bar
5 mm double bar
CNOMO 6.5 mm triangular
8 mm triangular
EDF 900
EDF 1300
EDF 1400

(1) Delivered without barrel. Please consult us.


(2) Diameter 8 mm.

65

Spacial S3D

Steel wall-mounting enclosures


Accessories

PB500354-30

PB500353-30

Door accessories

180 hinge.

Characteristics
Material
0D[LPXPORDG

Supply
Models

Door hinges
&DSWLYHSLQLQGH[HGE\DVSULQJ
Zamack body for ref. NSYAEDH180S3D, treated sheet-steel
body for ref. NSYAEDH120S3D, aluminium pin
b )RUWKHKLQJHWKHPD[LPXPDGPLVVLEOHORDG
RQWKHGRRULVNJP2
b )RUWKHKLQJHWKHPD[LPXPDGPLVVLEOHORDG
RQWKHGRRULVNJP2
%DWFKRIKLQJHGHOLYHUHGZLWK[LQJV
References
NSYAEDH180S3D
NSYAEDH120S3D
DB300096-48

180 hinge for S3D enclosure


Standard 120 hinge for S3D

66

120 hinge.

Steel wall-mounting enclosures


Accessories

PB500328-33

Door accessories

Characteristics

Material
Colour
0D[LPXPORDG
Dimensions (mm)
+[:
+[:
+[:
+[:
+[:
+[:
+[:
+[:
+[:

Internal door
b /RFNLQJZLWKPPGRXEOHEDUORFN
b The internal door can be installed directly on the front
face of the enclosure or on the step slides (not supplied
as standard).
b To mount an inner door and a mounting plate at the same
time on the step slides is possible as standard.
b ,QFRPSDWLEOHZLWKWKHLQVWDOODWLRQRIWKHGRRUVWRSDQGGRRU
VZLWFK)RUIXUWKHUGHWDLOVSOHDVHFRQVXOWXV
Sheet-steel
RAL 7035 grey
NJP2
References
NSYPIN43
NSYPIN54
NSYPIN64
NSYPIN75
NSYPIN86*
NSYPIN106*
NSYPIN108*
NSYPIN126
NSYPIN128*
Installation on the front of the enclosure (A)
or installation on step slides (B).
A

A - 51

DB300097-66

Spacial S3D

42

B - X (1)
B - 59

38.3

30.7

59

(TXLSSHGZLWKZHOGHGYHUWLFDOSUROHVLQRUGHUWRIDFLOLWDWHFDEOHPDQDJHPHQW
(1) Dimension resulting from installation on step slides: B-83 mm.
Dimension resulting from direct installation (without step slides): B-91 mm.

67

Steel wall-mounting enclosures

Spacial S3D

Accessories

PB500324-35

PB500326-37

Cable-gland plates

Characteristics

Standard cable-gland plate

Aluminium cable-gland plate

3ODWHGHOLYHUHGDVVWDQGDUGZLWKWKH
6SDFLDO6'XQLYHUVDOHQFORVXUH
6XUIDFHZLWKPDUNLQJVLQVWHSVRIPP
to facilitate drilling.

Suitable for non-magnetic applications.

Material
Thickness
Ingress protection rating
&HUWLFDWLRQV

Steel
1.5 mm
-

%UXVKHGQLVKDOXPLQLXP
3 mm
-

)L[LQJ
Other characteristics

)L[LQJE\RUVFUHZVDFFRUGLQJ
to the model
-

)L[LQJE\RUVFUHZVDFFRUGLQJ
to the model
-

Supply

For wall-mounting
enclosures (mm)
Width
200-250
300-400
300
400
500
600

Depth

Plate dimensions (mm) References


Width (A)

Depth (B)

No. of 6
holes

No. of
markings

No. of 6
holes

150
150
200
200-250
200-250
200-250

A
B
C
D
E
F

140
245
245
345
445
545

80
80
130
130
130
130

4
4
6
8
9
10

8
16
32
48
64
80

NSYTLA
NSYTLB
NSYTLC
NSYTLD
NSYTLE
NSYTLF

4
4
6
8
9
10

NSYTLAU
NSYTLBU
NSYTLCU
NSYTLDU
NSYTLEU
NSYTLFU

300-400

495

220

12

126

NSYTLG

12

NSYTLGU

250-300-400
300-400

D*
E*

345
445

130
130

[ NSYTLD
[ NSYTLE

[ NSYTLDU
[ NSYTLEU

DB300092-43

800
1000-1200

Type

6
P P

P = 25 mm
A

* Enclosure with 2 cable-gland plates.

68

Steel wall-mounting enclosures

Spacial S3D

Accessories

PB501865-38

PB500604-37

Cable-gland plates

Cable-gland plates with FL type cut-out for cable-gland


membranes

FlexiCable cable entries

Mounting instead of the Spacial S3D plate.


Cut-outs for installation of membranes type FL 21 (1), page 273.

)OH[L&DEOHLVDQLQQRYDWLYHFDEOHJODQGSODWHIRUVLPSOHDQGIDVWFDEOHHQWUDQFH
7KHUHLVQRQHHGWRGULOOKROHVWKHFUHDWLRQRIWKHFDEOHHQWUDQFHVWDNHVDIHZ
seconds.
b Installation possibilities: replaces cable-gland plate (S3D or CRN-G)
or directly on enclosure.
b Cable diameter: up to 26 mm.
IP55
b )LUHUHVLVWDQW&IROORZLQJ,(&
b 7HVWHGRQVKRUWFLUFXLWHIIHFW$N$IROORZLQJ,(&
-

6WHHOVWUXFWXUHGQLVK5$/
)L[LQJE\RUVFUHZVDFFRUGLQJWRWKHPRGHO

([LVWVLQVL]HVPDWFKLQJVL]HV PRGHOV RI6SDFLDO6'VWHHO


ZDOOPRXQWLQJHQFORVXUHV
b PHWDOOLFIUDPHZLWKSUHPRXQWHGPHPEUDQH
b 1 gasket
b +DUGZDUH

Effective cable entrance dimensions


(mm)
NSYTLCME
NSYTLDME
NSYTLEME
NSYTLFME

[

NSYTLGME

[ NSYTLDME
[ NSYTLEME

Mount FlexiCable on
your S3D enclosure.

PB501867-37

PB501866-35

[
[
[
[

PB502035-31

80

5.37

245
122
120

34,5
34.5
30

DB300724EN-38

DB300094EN-46

NSYTLAFL (4)
NSYTLBFL (3)
NSYTLCFL
NSYTLDFL
NSYTLEFL
NSYTLFFL
NSYTLF2FL (2)
NSYTLGFL
NSYTLG2FL
NSYTLG4FL (2)
[ NSYTLDFL
[ NSYTLEFL

Create a hole with


a screw driver.

Push the cable through


)OH[L&DEOHDQGQLVKRII
your installation.

PB502597-40

FlexiCable repair kit


7ROOLQXQXVHGKROHV
Reference
NSYTLREP

(1) Cut-out FL13 for depth 150 mm; and cut-out FL21 for other depths.
(2) With 2 FL21 cut-outs: ref. NSYTLG2FL; with 4 FL21 cut-outs: ref. NSYTLG4FL.
(3) NSYTLBFL with FL13 cut-out.
(4) TLAFL cannot be mounted on enclosure width 200 and depth 150.

69

Steel wall-mounting enclosures

Spacial S3D

Accessories

Characteristics

Cable entry material


Cable glands
WREHWWHG

PB500945-17

DB300733-16

PB502492-17

PB500023-28

PB501700-17

PB500024-33

Cable entries overview

Multi-A

Multi-C

Multi-R

Multi-T

Prisma

FL13 & FL21 type


membranes.

Circular
connector-free
entries.

Rectangular
connector-free
entries.

FL21-type
membranes.

FL21 or rectangular. FL13 & FL21


SUHFRQJXUHG
DQJHV

Multi-F

Combined
2SWLRQDOVSHFLF
cable clamp ref.
NSYAECPFLACA
to be used
On cable gland plate
adapter or directly
on enclosure

Soft membrane cable entries


No
No

No

No

No

2QPRGLHGFDEOH On cable gland plate


gland plate or
ZLWKVSHFLDOFXWRXW
directly on enclosure or directly on
enclosure
Medium
Medium
Full
Full
IP65
IP65
Medium
Medium

Medium
Medium
IP65
/RZ

Medium
Medium
IP55
/RZ

Medium
Medium
IP65
/RZ

Cable diameter (mm)


Cable Installation time
Quantity of cables
WREHWWHGIRUDJLYHQ
surface
&DEOHHQWULHVIRUFDEOHVZLWK No
connectors
Cut-out
FL13 and FL21
dimensions (mm)
([WHUQDOGLPHQVLRQV PP
[

From 3 to 15.9
Fast
++

From 4.3 to 15.9


Fast
++

From 6 to 60
Fast
++

From 7 to 72
Fast
++

From 16 to 50
Fast
++

No

No

No

No

No



WR

[

FL21

FL21

[[

[

[

&HUWLFDWHV
Flame resistance

750C

UL94-V0
650C

UL94-V0
650C

UL94-V0
650C

)URP[
WR[
)URP[
WR[
8/+%
-

NSYAECPFLA7
NSYAECPFLA10
NSYAECPFLA25
NSYAECPFLA33

NSYTSAM504SE
NSYTSAM508SE
NSYTSAM638SE
NSYTSAM6313SE

NSYTSA2414SE
NSYTSA2417SE
NSYTSA2422SE
NSYTSA2423SE
NSYTSA2429SE

NSYAECPFLBP**
NSYAECPFLT7
NSYAECPFLT25
NSYAECPFLT35

08881
08892
08895
08897
08898
08899

Installation possibilities

)OH[LELOLW\RIWKHLQVWDOODWLRQ
5HYHUVLELOLW\
Ingress protection rating
Cable retention

Medium
Medium
IP65
+LJKZLWK
cable clamp,
(upto 18 daN)
From 13 to 30
Medium
++

On cable gland plate On cable gland plate On cable gland plate


adapter or directly
adapter or directly
adapter or directly
on enclosure
on enclosure
on enclosure

References*

* For details, type the reference in the search engine of www.schneider-electric.com.


** Metallic plate.

70

NSYAECPKFL11
NSYAECPKFL7A
NSYAECPKFL7B
NSYAECPKFL10

Steel wall-mounting enclosures

Spacial S3D

Accessories

Simple-1

Multi-CR

Multi-H

&DEOHHQWULHVZLWK
dies for cables
HTXLSSHGZLWK
connectors.

)/LQVXODWHGDQJH 0L[HGPHPEUDQH
ZLWK,62NQRFNRXWV entries for enclosure
thickness
2 - 3.2 mm.

+DUGSODVWLF
Yes, cable die
and
NSYDCE
NSYDCE

Yes

On cable gland plate


adapter or directly
on enclosure

On cable gland plate


adapter or directly
on enclosure

On cable gland plate or directly on enclosure

/RZ
Medium
IP54
+LJK
ZLWKIDVWHQHU

/RZ
Medium
IP65
+LJK
ZLWKFDEOHFODPS

/RZ
Medium
IP55
/RZ

IP55
/RZ

From 3 to 31
6ORZ
++

From 12 to 25
6ORZ
++

From 20 to 40
Fast
+

Yes

No

No

[

FL21

Various circular hole diameters according to cable diameter

[

[

)URPWR

650C

UL94-V1
750C

750C

NSYCEJD
NSYCEJD3
NSYCEJD5
NSYCEJD7
NSYCEJD9
NSYCEJD11
NSYCEJD13
NSYCEJD16
NSYCEJD18
NSYCEJD20
NSYCEJD22
NSYCEJD24
NSYCEJD26
NSYCEJD28
NSYCEJD30

NSYTSAKFL

ISM71071
ISM71072
ISM71073
ISM71074

PB500099-9

Simple-2

Simple-3

Simple-4

Simple-5

PVC adjustable
cone-shaped entries
for enclosure
thickness
3 - 3.2 mm.

Quick cable entries


for enclosure
thickness 1 - 4 mm.

PVC adjustable
cone-shaped entries
for PG tubes or for
enclosure thickness
1.2 to 1.5 mm.

ISO cable gland.

IP67
Medium

IP55
/RZ

IP68
+LJK

From 18 to 87
Fast
+

From 12 to 50
Fast
+

From 16 to 44
Fast
+

From 12 to 40
6ORZ
+

No

No

No

No

)URPWR

)URPWR

750C

750C

NSYECPC3
NSYECPC5
NSYECPC6
NSYECPC9
NSYECPC15

IMT36179
IMT36180
IMT36181
IMT36182
IMT36183
IMT36184
IMT36185

NSYEC1
NSYEC2
NSYEC3
NSYEC4
NSYEC5
NSYEC6
NSYEC7

ISM71501
ISM71502
ISM71503
ISM71504
ISM71505
ISM71506

Soft membrane
Not applicable

IMT36172
IMT36173

PB500976-11

PB500267-10

PB500975-15

PB500266-52

PB500944-17

PB500106

Cable entries overview

Combined

71

Steel wall-mounting enclosures

Spacial S3D

Additional information

PB500366-34

Installation of 2 mounting plates in the enclosures


with width of 1000 or 1200 mm and depth of 300 or 400 mm
Step slides, page 212.

1 - On the 6 backstuds

2 - Two offset mounting plates


DB300099-32

DB300098-32

with depthwise adjustment


(3)

(1)

(2)

(3)

(1)

(6)

(6)
(4)

(4)

(6)

(6)

(5)

(4)

DB300100

(1) Left mounting plate.


(2) 5LJKWPRXQWLQJSODWH
(3) Central backstud.
(4) Bracket ref. NSYCRNGSDR with 2 M8 x 20 mm screws.
(5) Step slide ref. NSYSDRSDCR300 (depth 300),
NSYSDRSDCR400 (depth 400).
(6) M8 x 20 mm screw.

(2)

See detail A

Detail A

PB500367-34

Installation of Telequick mounting plates

6SDFHUVIRUUDLVLQJWKHPRXQWLQJSODWHLQWKHHQFORVXUHVHTXLSSHGZLWKVWXGV
Reference

DB300101

NSYEMR

72

You might also like