You are on page 1of 94
| at | SHREENATHJI-UDAIPUR TOLLWAY PRIVATE LIMITED Ref. No: SUTPLUDRNH-SAEr14/1478 Date: 11" February 2014 To, The Team Leader Mis Aarvee Associates Architects Engineers & Consultants Pvt. Ltd., . House No. 52, Jain Colony, New Bhopalpura, Behind Mataji Temple, Udaipur - 313 001, Rajasathan Project: Four Laning of Gomati Chauraha - Udaipur Section of NH-8 (from Km. 177/000 to Km, 260/100) in the State of Rajasthan under NHDP Phase {V on Design, Built, Finance, Operate and Transfer (Toll) basis. x Sub: Compliance-Typical Drain Section Drawing Ref: Your Office Letter No. AA/UDRINH-8/SUTPL/14/760 dtd. 16.01.2014 | Dear Sir, | dian letence to the above subject, Please find the compliance report towards your comments on typical i drain section drawing for review. Thanking you, Yours faithfully, For Shreenathji - Udaipur Tollway Private Limited Manager i: asabove Copy to 1. The Project Director(NHAN) Udaipur 2. Shri P.K. Desi, Director, HO — For favour of information please. 3. Mis CEG, Jaipur 4. Office File 7 commer Sadbhav Sormpntne Ade: } "TODAY FOR TOMORROW ‘Shreenathji-Udaipur Toll-Way (P) Ltd, | eye oftes :"Sadshay Hows", Op, Law Garten Poles Chow, Ke Sar tn Notes NH sbridge, Aymedsbad- 380006, Dia. Releamand (Rajasthan) Pin-o1202 i "1: #81 79 28463384 F +91 78 26400210 &: sel@sadbnaveng.com Mob. +91 a003082821 (Otte) oO COMPLIANCE NOTE FOR TYPICAL DRAIN SECTION IE LETTER No AA/UDR/NH- 8/SUPTL/14/760 Dated 16.01.14 S.No. | Observation from IE eply /Compliance from Concessionaire 1 | Design report for RCC and Stone | Enclosed. masonry drains (Un mountable and Mountable including cover) has not been submitted. Please submit design report for RCC and Stone masonry drains. 2 _ | Stone masonry details have not been | Enclosed. shown, Stone masonry details shall be incorporated in drawings. 3 | Distribution reinforcement has not | complied been shown at top face of mountable drain covers. Provide _the"| distribution reinforcement at top face of mountable drain covers. | Udaipur Section of NH —8 from | 260.100 in the State of Rajasthan on FEBRUARY - 2014 CONSULTING Engineers Group Ltd. CEG Tower, B-11 (G), Malviya Industrial Area, Jaipur-302017, Rajasthan, India Tel. No: +91 141-2751801, 802, 803, 804 Fax No: +91 141-2751806 Email : hgjpr@cegindia.com Website : wuw.cegindia.com Four laning of Gomati Chaursha - Udsipur Section of NH-R ftom Drainage Report Km 177/000 to Km 260/100) in the state of Rajasthan under NHDP. Phase IV on Design, Build, Finance, Operate and Transfer (Tell) basis TABLE OF CONTENTS 1.0 OBJECTIVE wu. 2.0 Hydrologic Desig 2.1.1 Design Storm 2.4.2 Peak Runoff.. 2.13 Coefficient of Runoff. 2.1.4 Time of Concentration .. 2.1.5 Rainfall Intensity. 2.1.6 Minimum Width of drai 2.1.7 Minimum free board 2.1.8 Manning's Coefficient. 2.1.9 Velocity of flow 2.1.10 Capacity of longitudinal Drai 3.0 COLLECTION OF DATA AND DESIGN ASSUMPTIONS: 4.0 DESIGN OF LONGITUDINAL DRAINS & TYPE OF DRAIN: 5.0 ROAD SIDE DRAIN. 6.0 DESIGN RAINFALL: 7.0 DESIGN CALCULATIONS. @ Pollan olan ae 1 Four Janing of Gomati Chaucaha - Udaipur Section of NH-8 (fom Drainage Report ‘km 177/000 so Km 260/100) in the state of Rajasthan under NHDP Phase 1V on Design, Build, Finance, Operate and Transfer (Coll) basis LIST OF FIGURES Figure 1: Super elevation drain in Main Carriageway.. Figure 2: Super elevation drain in Service Road Figure 3: Drainage Schematic for Cutting Sections... LIST OF TABLES Table 1; Coefficient of runofi(C) for Various Surface ‘Table 2: Minimum Free Board Required for Different Drain Width Table 3: Stretches for RCC/Stone masonry Drain. ‘Table 4: Design Procedure for Drain Section Calculation, @ Gaugebiecn ea : i | | Four laning of Gomati Chavraha - Ussipur Seotion of NH-E (from Km 177/000 to Km 260/100) inthe state of Rajasthan under NEDP Phase IV on Design, Build, Finance, Operate and Transfer (Tall basis Desinage Report 10 2.0 OBJECTIVE Road drainage design has as its basie objective the reduction and/or elimination of energy generated by flowing water. Provision of adequate drainage is @ primary requirement for maintaining the structural soundness and functional efficiency ofa road. Pavement structure including subgrade must be protected from any ingress of water; otherwise over a period of time it may weaken the subgrade by saturating it and cause distress in the pavement structure. Also, quick drainage takes away the water from pavement’s surface and reduces chances of skidding of vehicles, The project highway is Gomati Chauraha — Udaipur section of NH-8 between Kin177/000 to 260/100 in the state of Rajasthan has been considered for design of comprehensive drainage system to meet the rainfall characteristics of the area ‘The National Highway No.8 connects Delhi, Gurgaon, Jaipur, Ajmer, Udaipur, Ahemdabad, Vadodara and Mumbai and is about 1450 km long, It passes through states like Delhi, Haryana, Rajasthan, Gujarat and Maharashtra ‘The design of road side drainage system consists of provision of covered RCC/stone Masonry dr sections of the highway. The longitudinal drains have been designed towards ROW sides so as to cater the storm water from both main carriageway and roads, The width of catchment area equal to the width of ROW has been, mostly in urban sections while earthen drains in rural s considered for design. The drains have been provided throughout the project highway. The design has been carried out as per provisions of IRC SP-42:1994 and IRC SP-50:1999. HYDROLOGIC DESIGN Hydrologic analysis is an important step prior to the hydraulic design of road drainage system. Such analysis is necessary to determine the magnitude & on of flow. Hydrological data required for design include drainage area ni of flow, outfalls, other “app Water shed delineation, arrow indicating direct @ Conating Engines Group Ld Four laning of Gomati Chauraha - Udaipur Section of NH-8 (from Drainage Report Km 177/000 to Km 260/100) in he sate of Rejastien vider NDP Phase IV on Desig, Bil, Fiance, Operate an Transfer (Toll) bs Rational inethod is universally accepted empirical formula relating rainfall to runoff and is applicable for small catchment area not exceeding 50 square ‘| Kilometres. The various parameters and the procedures to derive the runoff by rational method! are described below. 2.1.1 Design Storm Storm drains are designed to route peak runoff generated by rainfall of IRC specified duration and recurrence interval. As per Section 10.11 of IRC SP: 42, | design storm shall be taken for 25 years return period for National Highway, ‘One hout rainfall data for 25 years return period in the project area has been considered as 80 mm as given in Fig 6.(b) of IRC SP: 42. 2.1.2 Peak Runoff ‘The peak runoff or the peak discharge for the given area is found out by using the following formula as per Section 10.4 of IRC SP 42: Q=0.028 PAL Where Q = Peak runoff rate cum/see P= Coefficient of runoff for catchment characteristics A= Catchment area in hectares Te = Average rainfall intensity in em/hr from intensity-duration frequency relationship for a specific return period and duration t in minutes, on | od 2.1.3 Coefficient of Runoff | Coefficient of runoff (P) for the given catchment area is not constant and it ' depends on large number of factors. Factors affecting the coefficient of runoff are porosity of soil, type of ground cover, catchment area, slope and initial state of wetness and duration of storm, The suggested values of ‘P” used in Rational Formula as given in Table 2 of RC SP: 42 are presented below in Table 1. @ elite Get oe ; Four laning of Gomati Chauraha- Udaipur Section of NH (fiom ‘Kim 177/000 to Km 260/100) in tho state of Rajathan under NDP Phase 1V on Design, Build, Finance, Operate and Transfer (Toll basis Drainage Report 2.1.5 Rainfall Intensity Once the time of concentration has been fixed, the next step is to estimate the rainfall intensity for the given time of concentration. As per Section 10.10 of IRC SP: 42, the rainfall intensity for shorter durations of sinall catchments is estimated using the following equation: T= F (T#1)/(T (Tc#1)) 21.6 Minimum Width of drain ‘Minimum width for lined drains as per IRC is given as below: . ‘Minimum width — 0.25 m (As per section 4.9.3.c of IRC SP: 50) 2.1.7 Minimum free board Minimum free board required as given in the Section 4.9.3 of IRC SP: 50 are presented in Table 2. Table 2: Minimum Free Board Required for Different Drain Width 21.8 @ Drain width Minimum Free Board required Less than 300 mm bed width 10cm Beyond 300 mm and up to 900mm |.15 cm bed width Beyond 900 mm and up to 1500 mm_ | 30 em bed width For Larger Drains Upto 90 em Manning’s Coefficient ‘Manning’s coefficient (n) depends longitudinal drain section, It varies for Manning's coefficient for various types “Wprdevonding to this table the ‘n’ value Ne ‘ ‘Trapezoidal stone pitched drain - 0.028 } Random tone in mortar - 0.017 / “ed RCC drain -0.013 Consulting Engineers Group Ltd Jaipur upon the surface characteristics of the different type of drain. The value of of drain is given in Table 6 of IRC SP: adopted are given below Four lsning of Gomati Chauraha - Udaipur Section of. NH (om Drainage Report ‘Kin 177/000 to Km 260/100) in te state of Rejasthan ‘under NDP Phase LV on Design, Build, Finance, Operate and Transfer (Toll basis 2.1.9 Velocity of flow 21 3.0 @ *. 4. Required data for hydrautic design As per Section 4.9.1 of IRC SP: 50, the velocity of drain is calculated using Manning's equation as vert xp ge Where, V = Velocity of drain m/sec ‘n= Manning’s roughness coefficient R= Hydraulic mean radius (A/P) in m S= longitudinal gradient of drain Minimum self cleaning velocity and allowable velocity for different drains are considered as given in section 4.9.3 of IRC SP: 50 and Table 6 of IRC SP: 42 as presented below: (0 Capacity of longitudinal Drain Capacity ofthe longitudinal box and trapezoidal open drain is normally designed using Manning's equation as given in Section 11,2 of IRC SP: 42. Q=AxV, ‘Where Q= Capacity of drain cum/sec Area of drain cross section m* V= Velocity of drain flow m/sec ‘The capacity ofthe drain is designed in such a way that it can carry the surface runoff generated from the given stretch COLLECTION OF DATA AND DESIGN ASSUMPTIONS: 2) Collection of Data 1. To design drainage system following parameters will be studied in detail 2 Alignment plan, L section, Cross section, & contour map of existing topography 5. All the existing CD works on the existing two lane highway are proposed for widening, reconstruction, restoration as per Concession Agreement k the characteristics of the existing sections unaltered, Consulting Engineers Group Ltd. sipur | Four laning of Gomati Chauraha - Udaipur Section of NH-6 ftom Drainage Report Km 177000 to Km 260/100) in the state of Rajasthan under NHDP Phase IV on Design, Bull, Finance, Operate and Transir (Toll basis 4.0 b) Assumptions 1, Rainfall data is taken for 25 years as per IRC SP-42 2. Drain section is designed for proposed right of way. 3. In super elevated section for service road, drain is to be proposed towards main carriageway of 600 mm half dia soccer type or 300x300 mm PCC drain and sorvice road water is to be restored at the end of super elevated section in a chamber: and discharge drain using 450 mm NP4 pipe in ROW side drain or culvert. DESIGN OF LONGITUDINAL DRAINS & TYPE OF DRAIN: ‘To cater the storm water from main carriageway and service roads the longitudinal drain has been provided along both sides of the Project Highway towards ROW side, The storm water from main carriageway has been designed to be drained out to side longitudinal drains. The drainage chutes has been proposed to be constructed where ever required and matching with existing locations of the same. The design of storm water drainage system has been done as per provisions and guide lines of IRC SP-42:1994. The efforts have been made to utilize existing open drains wherever feasible to achieve economy in designs. RCC/Stone masonry Drain RCC/Stone masonry drain is proposed in built-up areas. The general section of L~ drain consist a rectangular section of internal size 600 mm deep and 900 mm wide made up. Median Drain In super elevated section wherever NIB is proposed, storm water will be drain out from main carriageway through cut towards to other side carriageway. In Raised Median section median drain is proposed in super elevated section. The typical schematic in super elevated section is shown in Figure 1 é& 2 for raised median and NIB case respectively. @ fd gla canal ae exsTIg CENTER LIne PRIAGEWAY qt 95% iad Les m IARRIAGEWAY NEDIAN DRAWN SELECTED FLL Figure 1: Super elevation drain in Main Carriageway Drainage Report CENTER LINE KS ane TAIL -& L ei Figure2: Super clevation drain in Service Road Cutting Sections Catoh water drain is to be provided suitably on the hill slope above cutting to collect and remove the storm water runoff from upper reaches, Four laning of Gomati Chaurahs - Udaipar Section of NH-8 (from Drainage Report ‘Ka 177/000 to Km 260/100) inthe state of Rajasthan under NHDP hese IV on Design, Build, Finance, Operate and Traasfer (Tol) bass Figure 3: Drainage Schematic for Cutting Sections 5.0 ROAD SIDE DRAIN ‘The stone masonry drain is proposed as given following stretches. ‘Table 3: Stretches for RCC/Stone masonry Drain $. | Design Chainage(m)_| Length ‘Type of Drai Remarks No. From To (an) Service Road Side Drain 1 181750 182150 400 Stone Masonry Drain } Both Side 191900 205793 13893 | Stone Masonry Drain | Both Side 208360 | 209790 1430. | Stone Masonry Drain | Both Side 4 | 219503 | 219775 182 | Stone Masonry Drain | Both Side 5 | 21oi7s | 220180 | 1005 | Stone Masonry Drain LHS 6 | 220180 | 220900 720 | Stone Masonry Drain) Both side 7 | 221550 | 222410 860 | Stone Masonry Drain | Both Side 8 | 222410 | 223393 983 | Stone Masonry Drain | Both Side : @ SE aerer a er Karraitng of Comati Chauraha Usaipur Section of NE8 (om Drainage Report in the state of Rajasthan under NHDP. inance, Operate and Transfer (Tol) basis Kim 177/000 to Km 260/100) i Phase IV on Design, Build, i 9 | 224270 225270 Service Road Side Drain 1000 | Stone Masonry Drain | oth sie 231720 232720 1000 J Stone Masonry Drain | oth sige 240956 241360 404 | Stone Masonry Drain Both Side Main Carriageway Side Drain 205793 207793 2000 RCC Drain Both Side 218493 219593 1100 RCC Drain Both Side 221100 221820 720 | Stone Masonry Drain Lus 221820 E 6.0 DESIGN RAINFALL: An average #0 mm houtly rain fall fora retum period of 25 years as er provision and guidelines of IRC $P-42:1994 has been adopted for design, 800 | Stone Masonry Drain RHS 7.0 DESIGN CALCULATIONS Design Calculation for drain section is described as under. Detailed calculation is briefed in Tabular and normal format. Table 4: Design Procedure for Drain Section Calculation Data Type Value Reference | 80MM per hour 1 | Design Rainfall for 25 years retum | AS PerIRC $9,{2 Fie B page period Value of Co-efifcient of 2 ran on aie oF a sper Table Page 20 of RC bituminous/paved sufsce ‘Value of Co-efficient of Run Off P2 for sandy 0.20 As per Table 2 Page 20 of IRC ground with ight ; SP42 Vegetation @ Cong Ene Cp Lt gr Four taning of Gomati Chauraha - Udaipur Section of NH-8 (ftom ‘Kam 177/000 to Km 260/100) inthe stace of Rajasthan under NHDP. Phase 1V on Design, Build, Finance, Operate and Transfer (Toll) basis, Drainage Report ——_——_ ne Data Type Value Reference Width of aod BT /paved Surface-10 (7 m Bituminous/Paved 7 4 | surfaced catchment area pony och ate ee 7 including kerb shy) either side 5 | Width of Paved surface in 12.50 30 m in either side from center Built-up area ling -width of catchment area is taken in which 22.5m is paved Width of Earthen Surface surface and 7.5 m is earthen 6 | with light vegetative cover 7.30 surface. Ws Te of catchment area) 458.79 Culvert to Culvert Distance i Catchment area is calculated 8 | Catchment area in SQM 13763.70 ee widths 458:79°30 9. | Catchment area in Hectare 138 10000 sqm is equal to | Ha (p1*C1+p2*C24p3*C3V 10 | coefficient of Run Off Pyy 0.73 (pl+p2+p3)= (10 x0.9+12.5%0.9+7.5*0.2)/30 11 | Manning Co- efficient "n" 0.017 for Stone drain Proposed Road Level at 12th ee a0 sen 587.473 L Proposed road Level at Ch 3 12.060 586.42257 14 | Level Difference (H) 1.05 Te= (0.87 xL°/ Hy" L- Length of water travel which is i m ‘the total of carriageway width , Sol ae, gr gonventration 1 0.012 separator and service road width), set ls To ‘H-Level difference between at median edge and drain edge L= 18m, He 2.5*18/100m 16 [Assumed Size 0.90.6 bxd @ ae tote cad er Four laning of Gomati Chauruhs -Udeiput Section of NH-$ (om Drainage Report Km 177/000 to Kim 260/100) in the stare of Rajasthan Under NDP. Phase 1V on Design, Build, Finance, Operate and Transfer (Tol) bess Reference 17_| Wetted perimeter in M 2.10 full condition (0.940.6*2) Area of cross section of i 18 | txechannel i SOME 0.540 full condition (.9*.6) 19 | Hydraulic radius R 0.257 R=AP 20 | R*? 0.404 “Level Difference/Total length of drain section,, if this value is 21 | Slope bata lower than 0.005, itis taken as 0.005 22 | 805 0.071 23 | Mean Velocity of flow in 1.682 nx S05 x RS drain M/seo ce In this n is manning coefficient “| 2g | Time of Concentration for 0.076 | =Length of Drain section/ mean | disposal point_T; in hr velocity of flow/3600 Max inteiisity of rainfall as | Ge) in CM per hour for ia FFX(T+YT(¢+1), T =one hour, duration of 0.5 Hrs during E tis sum of Tot Tr 80 MM per hour storm 26 | Peak discharge run off Q 040 =W/a xAx $40.5.x R*? in CUM per second “ 27 | Qa(cumisee) 0.615 OK Safe Max Allowable Velooly 7 [25 [Misee 6 | As per IRC SP 42, ct ining of Goi n hi Udaipur Section of NH~8 from Km. 17 000 to Km. 260.100 in the State of Rajasth: BFOT(Toll) Basis FEBRUARY-2014 CONSULTING Engineers Group Ltd. CEG Tower, B-11 (G), Malviya Industrial Area, Jaipar- 302017, Rajasthan, India Tel, No: +91 141-2751801, 802, 803, 804 Fax No: 491 141-2751806 Email : hgjpr@cegindia.com Website : www.cegingia.com ENGINEERS GROUP LTD ‘nso 0 as cose | @sonsuerine eslgn of Oran & Drain Cover for Mountable end Unmountabe Drain POREERS GReue if Design of Drain 1600mm x 160mm Concrete grace = 2000 kant ‘Stee Gree = 50000 Nim Dens of back at 2000 Nim? Unit weight of RoC = 2500 kN? Unk weight of PoC. 25.00. kN? ‘Safe bearing capecty of sot = 200.00 kN? ‘Angle of intemateton of 04 fr acne Earth pressute (9) 20.00 Degree (@art80's.14%6) = 052 Redan ‘Arle of intemal ction of 0 tr passive Earth pressuie (6) 30.00 Degree For Component:3, Heine = 45m ‘S* SosFecoatiey (\V Seay cost +e0sh 4) were ANGLE OF INTERNAL FRICTION OF EARTH 8 ANGLE OF INCLINATION OF BACK OF WALL, 3 ANGLE OF INTERNAL FRICTION BETWEEN WALL & EARTH ‘9 ANOLE OF INCLINATION OF BACKELL ‘$5 30.000 deg, 0524 Radian 85 0.000 deg, = 0.000 Radian 32 20000 deg. = 0349 Radian e= 0000 eg 0.000 Radian Ke" Teo x 00x ade k=” o2are ‘Thetfore, Hosni coeclent of Avo eath pressure» KCOS\644) Kiet 02784 Fer component 4 Folnt = a5 om ($= ANGLE OF INTERNAL FRICTION OF EARTH “°° ANGLE OF INCLINATION OF BACK OF WALL, WNGLE OF INTERNAL FRICTION BETWEEN WALL & EARTH "=~ ANGLE OF INCLINATION OF BACKFLL Ge" ss000 “aes = 0524" Raion i 0.000. ees, 2.000 Raden 20,600, og = 0349 Redan a 0600 5, = 0000 Raden - en "a" Tom x o8s0x Bae : k= ozo ‘Thotetoe, Horeona oetientof Ave eat pressure = iKicostiué) °°" Kus 02704 Passive earth pressure CONSULTING Design of bran & Drain Cover for Mountable and Unmountable Drain ENGHEERS GROUPED . — 270 Ke —Tee0 x osdox 0.88 ie = 6.1054 “Thotfore, Herzntl coeficent of passive eathpressuro= K,COS(Si4) Kip 87572 ‘AdkSenal ereberge Height duet bad on embarkrrent = 1200 Meer arth Pressure (Component 4 clive ath pressure oerkNn® = 097 uma Ince fore acing = 820KN . eae (Overkening Moment = eosin = Ost tn jsurcharge [atv eats preseure = ook: == 0.00 m2 lacve force acing = ‘0.00 sn : anot |Qverturning Moment 00 ki 200 tm [Components lacive earth pressure 967 kiln? 097 uma [Ace fore acing = asekN : Deet loverting Moment eorkm = ost tm [surcharge [active earn pressure 74 stun? 087 ima ve orc ating 4.60 kN > ust loveruming Moment 1003 ktm = $100 bn [Paveive Bash Proscure on Componont Jconskerngpsssive earth pressuce acting on component 1 Jcoorient ofrassve arth pressum> = a" sr7 |nereore passive earth pressure = 19851 Hv? = 19201 ta Jeeta o satty orpassive pressure = 2000 lpacane tore ating = 05.054 KN asest [zossing Worent = 62.381 kn 6230 tm Maximum Overurning Moment : session = 461 tm “Weight of Components and moments of components about ey LET BL HT Weight [coo [Moment a a a a Zoo ass | 023 [azo 0.98 is Sp eae] ir] aes Ps [a STOEL 8 27280 | o.9s as weit ot Precast sab 2438 “07 Toto Resting Moment . s86t7 um = 3662 tm Noteenedang he weight of precast ab Stability of Drain “Toe dean i stable against overtuing 2s well esting Overtuning Resisting Moment . 26.017 km (vertring Moment 40.04 kth Factor of safety against overturning Resisting moment Overtuaing moment : 2m = Safe'against Overturning “Theefore the caleton of passive moment roqued for etabieng he crn —e ke = #607 = Sliding @ CONSULTING ENOREERS choUeLID Design of Drain & Drain Cove for Mountable and Unmountale Bain Honaonttfecestam-@ = 19.95 1a Resstng erce * 05x Veta fc + Pease force 23.344 18) Cheek for Sling Resisting free /Heraonal Force 1200 ‘Safe against Stiding Pressure at Bottom Net Moment 33.47 kun Vera tre 44.305 iN Dist of point of appeation of resutant rom a o7em Ecoentnty . 023m Pressure at toe = Wi t+ 6) 86 km? Pressure aloo = Witt ei) = 3832 wnt Design of Foundatior BM at we functon Constants e Ketittstine) pea etre opts oaured Toll depth povided Ettectve Depth provided coer fom ‘Area of tool riquired (ate) Minimum ares of steel 2 per RC Minimum are of tet eauied Provide rein for bending Bart are a 10 spacing requred 294 spacing provees $0 \otalarea provided 523.590 Detoenage cf tense rent provided "Not conierng he weight of precast ead Considering the governing moment 38.322 ‘The eaurement of reifrcementin refernse to lute 707.28 of IRC:78.2000 Reinforcement ontop face Minimum retercement = 455 300 ‘0752 Provide rit te bending da spacing roquea ‘spacing proviced (otal aes provided Distribution reinforcement ‘Averagaaepth ‘Area of istibuonrelvorcement Beth sie (026 x Provided mal stel a spacing requred spacing provid 453 300 York 207 24000 10.00 022 099 os? 18482 am 25000 mm 18500 am 15482 mm Hence ok 20147 mt on 22800 mm? 2060 mnt 28 20197 mnt Hence ok 111.000 mn? 185.450 mi | b | | | | CONSULTING Design of rain & Oran Cover for Mountable and Unmountable Drain | EXGNEERE GAGUPLIO Beslan forshearforee ‘Shea ce at stance & perm wn = 6a kW Eecbve hickress of base ea at datanco = 48800 mm Design shear sess = 008 Nin? : Pereange of tense rein Provides = 028 Pemiasble shew sess = 028 Nim te om table 128 of RC 21-2000, = 023 Ninn? > Opt Ok fan of | u 1 ean focbending moment ertcal relforcement: Outerfearh face, Bit atite base 608 Nm BM due to fton o tas t200/2 05x 1s 495 iN ‘eng att = oe Ccoratants = esr = 24000 = tooo 093 oer Depth requires 12014 mm “Tela depth provided 23000 mm Eecve Deph provides 43500 mm omer “om > 2006 mm Henao ok ‘Area of si rogure (iis) 29000 an? ‘Minium ave o stool 2 perIRC = ow ® ‘Minmam area of steel oqured 22200 nat Provide lr banging rom base rt ‘sa 0 spacng equred 288 Spang provided 10200 tol area povited 238 0 = 2080 ant percentage of sla en proved > one > 28000 am® Hence ok Hor nt Both f Deatibuonremercement = 012% “Toknese of wat at boro = 18500 i -Avea of tition eeorement 22200 rt { 100.25 x Provided mn sts! = ¥8000 \ Diameter ofters ® mm spacing equred on both so of etsining wal = 45208 spacng proves ce = 00m ontcal celforcament: nner foo, Wimimum vera refocament= = 194000 mt o 5460 mn Prowige rite banging bert ‘aa 2 | spacing eaured 453 spacing povided 300 | ‘ola ares provided 107552 = 167882 nt | > 111000 mn? Hence ok : Design of vertical wall 2 Basin for bering manent ‘Yotcs relforcement; Oulereart face, Bathe osse | 18M ave o freon of sad ta2s0/2 x05 x 18 so Design aM consuttine of Drain & Drain Cover for Mountable and Unmmountable Drain Suonensarate Design of Dratn & Drain Cover for Mountable and Unmountable Dal Covaterts ° = ear t = 2d00 m = foo Keirceme) = one jee = ba Orta) = be Dei equres 17708 wm ola pe provides = 23000 tm {ectve Dep provided 18500 cover somm > 17708 am Hones ok ‘Aten tte! egret tn) = sit6 ant esa area tao as per RC = on ® irmum atea of ste roqued = 2200 amt | Provide rein for bending fom base fart | a 0 aco egued to spacing proved 4500 | (oa eroa provided me} = 52200 mt? eroanage of tne en povided = 028 > st16 mm? ones ok | ovtzontal enforcement: Both face, Disrbutonrntscement 012% | “hikes of wala oto 42500 eum | ‘re of disbtoneitroment 72200 mnt | 210.25 xProvsed main see 4090 iameterotbas & mm ‘paving requred ‘on both side ofretsining was = 45286 | spacing provides lo 300m | ‘Sta provided on bot aco 886408 mm? | Mimi vera! eocermert= = 111.000 an? | vor = 654500 nn? Prove efor boning Bont ‘da 2 recog reaued 35 acg provided 00 {oa era provided serss2 = 197852 annt vearageofesie ret provided 087 > Stneco mt | Hence ot | Ghecktorstess | Settoasel Sab : 177040 | toad on Sige ot 820 Masimum Vericl Load on ede walt 200 ia | Moxmun wath ef spelen aces oan 1.3843 m | ‘Thomess of veal wat 023m | ‘xia Compresabe Svess = 67581 kNsg | 0.58 ha Permissible ec compressive svese (R21) MPa | Hence OF | Bending Stross due to arts Pressure (EP) . ne 178 Pa | {omined Asses (due overeat Li) & Bending sess (ue OEP) = Pays = 248 wea Permissbe feral compressive sess (RC 21) : S67 Wea | ence Ok | CONSULTING Bvoncens cour UD Design of Drain 1600mm x 1200mm 24 ity condor | 200 | 200 | Serves Read concata grade "i" ‘Stes Grae Fer Density of back Unt weight of RoC Unt woight of oC Safe Bearing capacty of st ‘Angle interact ol for acive Earth pressure (6) ‘porte0'. 1416) Ange of internal faton of ofr passive Eath pressure (6) Enrtn Pressure coetclnt For Component-3 Meignt 42m Ree cos’ cose CORE) (a “SNGTarsINCe==) 2 GOS + ACOs =<) ANGLE OF INTERNAL FRICTION OF EARTH ‘ANGLE OF INCLINATION OF BACK OF WALL ‘3 ANGLE OF INTERNAL FRICTION BETWEEN WALL & EARTH 47 ANGLE OF INCLINATION OF BACKFLL were $= 20.000 og, 0524 Radian 2 9.000 ag 0.000 Radian B= 20.000 oop. 0.349 Radian a 0.000 og, © 00 Radian a ‘Therefore, Horeonlacoeicert of Active cath proseue= K,COS{64®) Kin 02704 For Component 4 Height = 12m {4= ANGLE OF INTERNAL FRICTION OF EARTH 1b = ANGLE OF INCLINATION OF BACK OF Watt '5= ANGLE OF INTERNAL FRICTION BETWEEN WALL & EARTH {47 ANGLE OF INCLINATION OF BACKFILL 4= 30.000 dep 0828 Redan = 0.000 ee 0400 Redan B= 20.000 dep S o42 Resan a= 0000 eg. 000 Regan — 21a Kan Taine osaox 260 ke 02ers ‘Thereoye, Horizontal ecefclet of Acve earth pressure = KCOS(610) 7 Kus 02784 Passive earth prigsure = 2090 = 500.00 20.00 25.00 = 200.00 20.00 = 0B 30.00 = 082 of Dra & Drain Cover for Mountabie and Unmountble Drala hake Nn? Nn eum? i? ei ey Degree Regane Degree Resans @ Consutting Peston of Bran & orn Cover for Mountable and Uemcunable Dain EGWEERS cROUPLID ee OM TOT ko = rose ‘Thertor, Horzantalcosfcent of passive earth pressure: racos(0) Ke? arse ‘Aéaioral surcharge Height de to load on embankment Earth Pressure [empenen re crt pressure = 7e2kwn® = 278 oma [Acve ree acing = 54 ka : asst loveruning Moment = 220k = 032 Isurenarge fact earh pratsure = 9.00 ng 2.00 ume [ctve ores acing = 2.00 kN : uot lovenuning Moment = 200i = 2.00 ten [Femponent [Active earth pressure © 2a2 Wm? 078 ume [Active toes acting = sae un . vase [Qverturing Moment 822 by 232 tem [Surcharge Iactve esrh presse e7thWm® = 087 Una [cave toro acting = 939 6N : aot lOverueg Rment “= Ssrkm 2.68 tay [Fest Ein iss os Copaneney |Corsceing passive eat pressure ating on component + (Cousot ot passive cart pressure = a= err {hertore passive extn pressure = 100.54 kan? : 16.084 ume Factrotsatetyroasshe pressure = "og Passive foes aca 55.224 4a : sexe [Resisting Nement = 28.0604 = 3308 ty ‘Maximum Overturiag Moment . Sram Weight of Components and momonts of components about Wee a amar * im cm m KN mn cal Po ea ro aan a pe Soa a Fa ts SET 0ar Tatas not ot Pecan sap SE 3208 “Tota Resting tomont = ps0 Stabitty of Dain The dain stati gant ovate as vod a ing Overturning Restrgtomeat : 2555 thn Ovetumimgomet 79 4am Facorofssety againet overturning ™ Resiting moment Ovetuilng moment ri 2.509 * Safe against overturning ‘Treefrethe catelaton of passive moment sequel for tb the ain eee mene = 34800 Sliding Horizont eee stom 1485 48 = 1200 098 tm 2558 tm Meter Not consaoing he weightof precast sab | CONSULTING Desig ofa. Drain Cover for Mountable and Uemountale Dat biel Resting force = OSxverca face + Pasavetorce Noord te weigh of roast eab ‘rae mt hesk er tng * Resting foc / Herta! Fores - 7 ‘160 = Safe against stising Pressure at Bottom Netoment 21.9430 Conierg he govering moment Vertes eco 28525 1 Dike port of aptiasonfcesulanttoma = O77 m Eroennty : 2ibm — 159090 nm Proteus at ton = Wits 6a) 820 sein? Pressure att = WU 6) = 2004 faim? oH a2 2aas ‘Desian of Foundation Cal Desf: bina moment [BM at the junction = are km Conatans ° = oer ” {000 | Resqrstme toa is > oa | esi =o | Depth ered 2089 mm | “ata op provided 000 Etecve Depth povides ‘seo am cove ann i088 am | Hence ot | ‘Aron tel eguired A) = Lt an ‘Mimo area ota or pe" Zoo ‘Mrimum ares Sea equred = ti720 amt | Prove renter bendeg fant ose eo 2 Spacing requees 170 | acm proves 120 i ‘eaeres proves osre since an? | arcanage of ens ran prevced + oar | moist an? i ‘Hence ok | “ne reqrement ot enecament in seteenc to lt 707.28 fC 78.2000 Reintorcementon op 68 Mem torment = = ssmnt on = seam? Prose eto bering eat ia 2 Sacra equed or Specie reoies 00 | ‘ia res proved 7882 = 197882 ot > 93.600 mm? vince ok Dittbuten reinforcement ox verage seh ‘e000 im, ‘eael detbuionecforcement Soh side e720 om : 0.25 x Proved ai oe outa me | sy die a Spacingrequed 5a i Spacing ronns 300 CONSULTING esi of Drain & rain Cover fr Mountable and Unmount in Sousurtine Design of Drain & Bran Cover for Mountable and Unmountabe Dra SSeS Sr . ‘Shee ce at astance 9 parm ksh Sas aw Etectve thickness of bae lay at catanca¢ = $8600 am Design shear sass 203 tin? Fercentge of tnsie rit, Provides = oar Peimissibe shear srese = 023 Nim? “e ffom able 128 of 21-2000 223 Ninn? > 003 on not} rm 1 eta entorcoment«Outerearth taco Binet dace 2322 ktm ‘8M dueo ftom of ia t2938/2 x05 12 = 3a5 im 30.Desgn a = Tori Constants ° = eer : t = 000 nm = i900 keqaoume) oz pra = 089 =t7204j = oe? Depth require 10254 mn Tol depth provided 20000 nm EEtlecve Depth proviced 188.00 tam cover 40mm > 10254 im ence ‘cea of tet roquied (aia) 20351 mn? Mix area of tol es per RC on wl ‘Mumm area fees requed = 18720 am? Prowse rent for bending from bese Bert ‘da eo spacing oqued 27 spacing proviieg 2 00 ‘etal aes provized ey = 41888 mn? Percentage of terse ren pevded = on > 20951 mn? Hence ok DSorauien eeemant: ota ce = asm, ‘Thickness of wal at ote = 15000 mm ‘20a of dsttenrtetoroment = 10720 mt 00.28 Provided ai 10472 Diameter o bars a am spacing requed ‘en both ste of eaning wall = sero spacing povided le 7 0am Mnimurn vetcarefrceme 98600. mm? o = 960 mnt Provider er bending ar a 3 secing reqs esr spacing proves 300 ‘eal tea proved 87.82 "187552 mn? * $9800 mm? Hence ok nof ve 1 2 22st forbendna memant Siratpeeiements urn ace “976 Me fet of slab 2008/2 x05 12 30 Deson Bl constants € = eer ENGHIEERS GROUP LID | | CONSULTING Desig of Drain & Drain Gover for Mountable and Uamountabie Oran ‘ = 24000 ™ = i000 Ketisovme) = om 3 = om aire) = 087 . Depth routed = 24s om Teal pth provides = 200mm fective pth provides {2800 mm cover 50 0 > 24s nm ere ok ‘rea sal equred qu) imum area of steal as por RC ® Saco ae Dose ll < ai aes S inona, ets Soe, au re trot os ae ) ae fees aan ot ene a =, “ ee 22 | ole am emt reer arldscure | eee et ee ee | parties o “ ; leas - Sagem & {otal area provided 167.552 = 167552 mm? | er sae Re > $3,600 mm? ects Hall ee “a seceneess sesh 2 eee eh onan sn ctl Peimissble Direct compresswve stress (RC 21) Bendy Sess due to Eath Pressure) . tn = ‘Combines All stoss (due ovetal L)& Bending sess due fo EP) = PIM = | | | Mista | sraacratroaeaereegets : | @sousuarins ENGNEERS cRQUALID Design of Drain 1500mm x 900mm Lilly Conidor | 460 J Density of back fi Us weit of Re. Unit eign or Po Sete beating capac of 08 ‘Angle finer teton esl for acve Earth pressure (4) 3000 Dagrae (eor80%3.1416) O52 Ragne ‘nal fintemalfc8on oso for paste Earth pressure (4) 2000 Degree Earth Pressure coeticient For Component-3 Hoge Ose CORE) vere = ANGLE OF INCLINATION OF ‘30.000 deg, a = 0.00 dog : = 20.000 ep, c= 0.000) deg : ee ke estan of Draln & Oran Cover for Mountable and Unmncuntabe Drain os so ‘Service Road = 2000 km? 500.00 Niner = 2000 kN 2500 kN? = 2600, kN? = 20006 kin? (7) TREE (Vee > ANGLE OF INTERNAL FRICTION OF EARTH 8 ANGLE OF INCLINATION OF BACK OF ACL, = ANGLE OF INTERNAL FRICTION BETWEEN WALL & EARTH BACKFILL Therefore, Horizontal coffe of Active earth prseure = For Component 4 Hen S7ANGLE OF INTERNAL FRICTION OF EARTH 8 ANGLE OF INCUNATION OF BACK OF WALL. = ANGLE OF INTERNAL FRICTION .&= ANGLE OF INCLINATION OF BACKEG $= 20.00 eg. : 85 0.000. dos = B= 20.000 dog, = = 0000 dog : Ke" ee ke ‘Theos, Hodunta consent of Active eat presue K,cOS(e\6) Passive arn pressing ‘0524 Redan 0.000 asian 0369 Raden 0.000 Ratan Ooox 28m 20a Kcosess) Kies “0.2784 08 om BETWEEN WALL a EARTH: 0824 Radian 2000 Radian 0.349 Raden 0.000 Regan ‘090x268 2073 Ku oars CONSULTING Decigt of Drain & Drain Cover for Mountable and Unmountable Drain WGNEERS gROUPLO a) Ko Tho ootox oat ip 61084 “Tereore, Herzortal coolant! passive ear prossire = K,COS(Gs2) . Kee S7O72 Addon] surcharge Height uot oad on emberkeent 1200, Meter arth Proseura [Componont Jace exh pressure = 92 bet? os uma lacve ree acing 24 IN ostt loveruring Moment = S40 = O14 tm lsurenarge brave ean prossue oom = 0.00 va Jace toes ting 90 aN : 2008 lovee tement Qookin = 0.09 tn (Companants [rcv corn pressure = seam? = 058 uma Ince foes acing = 4 : oatt lovertuning Moment a0 en edt fsurcnargo lace eat prossuce = 57 aN? 0.97 ume Tact tees acting 744 one [overing Moment arm = 0.23 ten aaa Banh Press on Component 7 \ceneteing passive each pressure actng on comsonent 1 |coutcert of passive cart pressure = Kon = srs etre passive earth pressure 421.99 tin? 42168 m2 Iretorof aot fr passive pressure 200 [ress fore acing = 32201 kN : s2at Resin omer 14249 iN = 1495 tm tasximum Overtuning Moment . SABA = 052 tm “Weight of Components and moments of components shout oy eB] #1 Went [ oce_|wonent a a Pope ie 7280 foot [eees Fe a SET aT zas [0TH Weight o Procast ab 20 25821 Total Resisting Moment . ssr99 4m = 4.574 tm Notconsoetng the ight of recat ‘Stabilty of Drain “Tho stalni tale opairst overuring at wel a cing overturning Resisting Moment = 15750 480m veruring Moment . 513m Factor of aafetyagainet overturning = Resting moment /Ovorturning moment on : 3.088 Safe against Overturning ‘Thetlee the cleat of padsve moments requtd for stabising th ran, iv ese 2 BRL Sliding Novara! forte sted 7 1925.40 @ CONSULTING Pence ‘Design of Draln & Oran Cover for Mountable and Unnountabo Drain Resting force Oona! faces Pash ore’ Netcong wight of recat lab Worse heck ig = Resting tc Hrzona Face ‘ore Safe against siding Pressure at Bottom NetMorant 2175 thm Considering te governing manant Vera ce = aus Dot att peteaton crest tom 8 78m Eccentieny asm — 118.09 my Press atoa = Wnt 68) = 87 tnt Pressure at toe = Wik 80 Hence ok Are of st! regio 20000" nm Wiimote et perc > aw yf Misra are ft eqred = 13020 ant Prove ror bending ent Ba a * SDicng readied 28) Sac pevced jap teal are provced 33509 = 93510 mn? clas of ens toed = on > 200.00 mun? ene Th regan’ of recent in efecto cow 7072 Bot IRC-7e.000 Roiforcementon top face Mirae = eee mn? fa 2 ates mm? rove rt for beng ea ‘ie ‘ soc eae we Stacia rte eo tate roves verse Distouten reinforcement average depth ‘Aa ol dtioutoneefocement th sida 27025, Proved maa te > dia 8 Secng roused ho sp20rG proies 300 | | consuLtin ‘Design of Brain & Drain Cover for Mountable and Unmountabte Drain ‘peslanforshear force Shear fre at satance d poem width Efecve thekness of baa eb at stance & Design shear sess Percentage of tens et. Prov Permisuible shear sess “rar able 128 of RC 24-2000 Design of vertical wall 1 Basin banion nat BBM atte base BM duet feo of ab yams/2 x08 x os 0 Desln BM ‘constants t « sit) KS e172) Depinreqates “Total dep provided Efcve Dpth provided ‘rea of steel requires WD) ‘Minmm aes of ta! as parC Min area of see reues Provide rent for bonding tom base Bart aa sO spacing equred 32 spacing povses 10200 total area provides sssie 0 poreatape of ese en rowed Horizont. ta Datbuton rontrcerarn “richness of wal at tlm ‘es of etd enoremert "01026 x Provided mal stew! Diameter of bars space requed ono se ofrtaining wa spacirgprovided oc f a Mmieum vrial toresment = Provide ref for bending bart ‘da 3 spacing rogues ra teaone provided 300. ‘etl ea proved 167.882 Design of vertical wall 2 Dash for bending memiet Yertclseifoccement: OuterfEanth face Ba ato ose BN dietothetonof ead s2205/2 x05 x 09 0 Deegn aM 253 KW {1600 mn 092 Niet 028 02 Ninn ozs Ninn? oa2 Ok 140 kim 278k a him oor 240.00 {0.00 az oe 087 yess wm oncom 11600 mm wees am. Hence ok ye130 ant oe 19620 ent *ms40 ont 029 16119 mt Heron ok 012% 116.00 nm, 3920 eo e370 8 om raat 0mm 9600 mt 41800 167882 et 69800 mnt ence ok CONSULTING n of Dra ver for Mount @sousyzne Design of Braln& Drain Cover for Mountable Ind Unmourtable Drain = 24000 = 1000 Kenreve) oz a) 093 aire) O87 Depth requtes = 10861 mm Toll dept proves = 16000 tom EecbveOepin provides 11600 fim cover om > 10881 im Hence ok ‘Ares of tel rqured (arg) 207.04 ran? Minium area of steel as pos IRC ‘Mumm area of eee! recred son y = 139.20 mn? rove rent or banding rom base Sart a ar) ‘spacing requred 14 spacing povided 150 200 {otal aoa povided 25104 “9 335.10 mm? Petcontage cf terse ent prowdee 02 > 30708 ment Hence ok Hetzontl reinforcement: Both ace Distieutonreniorcement = ora ‘Thickness of wal at bot = 11800 mm, ‘Are2 of dtibutonreerement 13820, mn? ££ 0.26 x Provided main steel = 8570 Diameter of bars = xm specingrequea ‘on both side of rearing wa = rea spacing preided ale a ay Stel provided on tet ace 236.106? Mirieum vera refocement = 99000 mm? or = 41808 tome Provigo ret or tening art ‘da 3 spacing requred re pacing revced 300 (otal area posed 17852 107852 mn? eentage of ens ref provded 2.029 > 99600 mnt Hence ok ‘Sheek tor Stee Se Loud of Sab 16.51 Wy Load on Single wat ‘826 KN ‘Moxsnur Verteal Lead on side wa 200 kN Maximum wath of eapersion across span 19843 m “Ticks ofveteal wat 036m ‘ail Compressive Sess 908.24 sNveqmy 97 MPa Permissibie Dvect compressive sess (RC 21) : ‘MPs once O€ ‘Benaing Stress due to Each Pressure (EP) tyne 1.38 MPa Sonined tal seas (uo vera LL & Beng sess (ue to EP) Pianyn 295 MPa Pesmssibe Renal compresshe sues GRO oth : 807 MPa Hence Ok CONSULTING Design of Brain & Drain Gover fo Mountable and Uneountable Oran NONEERS gTCUPLTD Design of Drain 120mm x 4200min a ‘usny Comisor | 200 | | 200! ‘Service Road 1700 . Concrete grade tt = 7000 Nin? Steel Grade"Fo" = 50000 Ninn Densty of back = 2000 Kin? Lunt weight of ROC = 2500 Kim ‘niteigt of 2500 kN? ete bearing capacty of sot = 20000 AN? ‘page otinteal con of efor active Earth presse (4) S000 Degee (oorters.xat6) ose Ragans ‘ale of intra rtion of ol foc passive Eats pressure (+) 3000 Degee = 082 Radians arth Pressure coetftont For Component 3 Mout = = 12 peariee x ToS Toomee) [i+ / SETNSTMA=a) (COS + 3]COS-«). WHERE i= ANOLE OF INTERNAL FRICTION OF EARTH 87 ANOLE OF INCLINATION OF BACK OF WALL ST ANGLE OF INTERNAL FRICTION BETWEEN WALL 8 EARTH {27 ANGLE OF INCLINATION OF BACKFILL ‘= 30.000 des, ese Ran 82 0.000 ep, 0.000 Redan = 20.00 cep. 0349 Radan = 0000 cg === .000Rasan - so __ Ken Savy asdox 264 kon 02073 “Therefore, Moran coetilento Acve ear pressure = K,COS(62) Kus 02784 For Component Hetgnt 12m ANGLE OF INTERNAL FRICTION OF EARTH TANGLE OF INCUNATION OF BACK OF WALL SS” ANOLE OF INTERNAL FRICTION BETWEEN WALL & EARTH (TANGLE OF INCLINATION OF BACKFILL $c'sp000 dep 52K Radian 32 oo cep = = 0.000 Ratan $2 20000 dee = 0a Radan 13.00 dee = 900 Redan 840K 26a ozs oizontal oaticient of Active eathpressue = K,COS(G¥0) Kae 02TH @ CONSULTING neo Design of Drain & Drain Cover or Mountable and Unmountabe Drala a 18° 00 ao aT we ‘Theroore, Horzonilcosicont of passive ‘Adidorl surcharge Height due to cad on emt Earth Pressure 7 [Component + lac ear pressure = TerkNn® 078 ume 1068 earth pressuce= Kycosiero) Kes 87972 banknent = 1200 Meter face tere acing = a8 ka ose lovernening Moment “= 3.22 Kiem 232 ten fourcnargo ve eet presture = ocoKwme = 0.90 uma facive oce acting = 00aN ooo [Overwmieg Moment = 200 Km 2.0 tn [Pempenent $$$ lace care prassure = Taekwn® = 076 ume lactve ore ating = 548 in oss t foverurning Moment = S2km = 032 tn fsurcnarge WAcve earn pressure = 71 bh? lAcive eco acting = ea0an loveruning Moment 857 Kil [PassW Each Pressure oa Conponaatt [Sonsiterng passive eat pressure acting on component 1 [coeticiontot passive contipressure = a= 5797, herotere passive earth pressure = 100.84 kN? 4 16.084 ving [Facororsatey torpasshe pressure = ‘S'909, Passive ree setng = 98.224 a : ss22t Iesising Momont = 8.060 Km 3306 em Maximum overturning Moment . areiem = 298 em /Helatot Components and moments ot componente abouta Ten mgt | see omen Sa Bn Poe eee BP e192 aoc oe So acco Fs EE CC To 323007 220 Total Ressting Moment . 20820 im = 20826 Net considering the enh of precast ob ‘Stabitty of Drain ‘Te rain is stale ago ovetuing as we a8 sing Overturning Resleting Mement : 20.820 e8-m Overtaring Moment : 70 kum actor of sofey against overturning = Resisting moment /Overurning moment = Safe against overturning ‘Therefore te caeuaton of passive moments 8 Sliding Hevlaona tore stems 7 2126 require for tabilsing the dain ex 8 25240 6.558 kN 143s CONSULTING ‘Desig of Bran & Drain Cover for Mountable and Unriountable Drain EHOMEERS GROUP LTO Resieting force = asVertealfore + Passive fxco Not consdorng the weight of precast sab 18aTS AN ‘neck or cing = Resisting force / Horizon Feice F - 109 = Safe against Sliding Pressure at Bottom so {20 en omen een nema aac Bry seer aletncrestmitons = “aaa Ee 2 ame —= pried pessutto = hi) sie st Petes cw Si ime an s se ‘Design of Foundation Schild aia ein an tim cet os Sun Er 022 | Ea | oe oop aes nee om | ee Se & etsetape oie ae ae om See a Anon maxes cae a scioceettsit ee Daeg Sno ences Date at rote en tet ont e ‘ Sensnina 1 Saence : Soneperis ane Sa ETc 1 ee en “ieee deena cn sa 70128eR6 76200 Aeron ontop ‘Seman 5 eat = 1 BSc ‘Provide rein tor bencing Bart | % : ‘pena & ‘Segoe = Compo wre nto tran : | Rea : | Micon scant sana : ee ; ossxroseaes : y o : : Serowngs feeong provided 300 CONSULTING Desi of Oran & Oran Cover for Mountabe and Uninountabe Dain ‘Shear free st stance d per m wise) = 537 Kw fectve thickness of base slab at datance = 16800 ham Desimn snearstaes = 003 Nm? Percentage of ters rein. Provided = om Permissibie shar atess = 023 Nit “from able 128 of 21-2000, = 023 Nn? > 003 om Pestn fo bendina moment ‘tle roforcement: Outer face Baath oace = aa kum EM duo feton estab 1090/2 x05 12 = 32 itm so Design Bit 2 38m constants © ear t 240.00 m ‘0.00 Keettoume 02 ints oa Genk) = oe Depth regued = 9806 mm “ola sop provsed = 20000 fam Eflectve Depth provided $86.00 im cover 40mm > 9808 iam Hence ok ota of tcl eared (i) 18602 mn? nino area of teat es per IRC on ‘Wnimum area of let requrea = 16720 mt Provident or bending om base Bart de @ apacig requed 259 spacing proved 20 200 41880 = 41888 mn? ereentage of tense int provided = oz > 18720 mt Hence of so Disinaonrltorcomont ax2% “Tienes wat at Btiom = 15600 mm, ‘ie8 often riforcment 38720 mnt 00.25 x Proved mai tel = jee Dlamoter obars = 8 mm ‘spacing rowed ‘on bath seo tang wa! sore spacing provided ce "300mm Mima vena refecemont = 98800 aan? s2380 mm? Provide rit or baning Bert a ° sacngrequres 7 spac proves 300 ‘wal area provides 161.852 = 187852 ant > 95.800 ant Henze ian of ve Hh asian focbencina cront Sirens: ara ce BM dua febon of ab 1080012 x08 12 s0Dotign BM Constante e CONSULTING ‘Design of Bran Drain Gover for Mountable and Unmountable Drala sega \ = aus * 2 ie eta es 103 Desens iat pierteuney oth tcc one mo mn ae 00m » Bem oneck ‘Aga of stee! requred (Mid) 975.24 mn Aisle sept tee ttarum acto eae fare Pork te bert Fa ve Ske an te ata ea Sieve ree an 7 ine ot ae et od of ee ek / : sears + ose Ter sar aan Se) om Nene camoneciocnnt wo S028 Pet an sd He Darts es Feit vba ect at farce ‘ee powoce Sam tp cath ie ct ot vate maine eevee icon ose mt ° se Protea te 2 : Ses nae sx Shapewse oo Sens pons vere = wee ot ‘ear ct poe ot Deo am? ‘ee ave orseee Sear v4aa ett 1a ies oson wnat et tent he denen 27 tae ane eae Sit itnee sat cone See ‘rea isan Poms ec iments 2) es veceoh bern hn dn Ea Pre = ae Continthossion Gitovtalleeréegsbn(iebE®) = PAM = aa Fema tonrsesve ee ORO) Die ores Ob cousutrine Daten ran ot Use @cceguasine einer " Design of Brain 1200mm x 900mm 7 a LUity Conidor | 160 | | seo! ‘Service Road — Se » Sorcrete grade Ne 2000 kevin? Steel Graso “Fi 500.00 Ninna Density of back ft = 2000 Nin Untweiht of Ree 2500 Nim? Unitweignt of Poo = 2500 ken? ‘Sle bearngcapscty ct so = 20000 ein? Angle final con of sol for sove Eat presse 4) 2000 Degree (oor. 1416) = 052 Radane ‘Anal ofiteralcton ot sol for passive Eat pressure (4) 20.00 252 Redians | | Earth Pressure eoefficont i Fer Component: Helgt = 09 4 : 40 | “* coseceanay 7 “SNES ay E 2086 + 81C08(0-<), | were SE ANGLE OF INTERNAL FRICTION OF EARTH = ANGLE OF INCLINATION OF BACK OF WALL. Sr ANGLE OF INTERNAL FRICTION BETWEEN WALL & EARTH = ANGLE OF INCLINATION OF BACKEILL | $= 30.0 eq =. 0824 Rafen 8= 0.000. tog = 0000 Raden B= 20000 og. = 0349 Raden = C000 dep = 0c Radian | Moy tba aaee we oaers Therefore, Horzontl cooteentof Ace earth pressure © K,COB(éi8) Kus “02704 ECANGLE OF INTERNAL FRICTION OF EARTH = ANGLE OF INCLINATION OF BACK OF WALL Sc ANGLE OF INTERNAL FRICTION BETWEEN WALL & EARTH (i= ANGLE OF INCLINATION OF BACKFILL . | | | For Component -1 Hot = as | $= 30.000 des, D824 Radian 8: 0.000 ae 9.000 Radian | B= 20.000 dep. 2.340 Redan a= 0.000 dey. = 0000 Reson Me" eee ono Baa : k= ozers ‘Tete. Hoos coetcent of Active eat pressure» K,COS(i8) Kus “027 8216 Ga possure CONSULTING ‘Desig of Drln & Drain over for Mountable an Unmountable Oran Seago vwelaiof recast slab "9-H ome OH lp =” 6.1084 ‘Tacelore, Hodoral coeticient of passive earth pressure = K,COS() Ke 87972 Aion surcharge Height due to oad on embark 4.200 Meter ceatn Pressure {Component t Lacie ear pressure soak? = 0.9 ve Iachie toca acing S16 aN : oat [overuming Moment savWim = Oi lsucarae Jacve ear pressure = 0.90 sume 0.00 uma Jace ree acing = 1.00 N oot loveruing Moment = 2.00 m= 00m [Components lacie ear pressure = Seek = 089 va facie tore acting = 54 KN : pate lowering Moment = S4okN = Oia to surcharge cve ear pressure ert nun? = 067 ma lacie force acing = te : ont loverurringbmont = arin = O86 tn [Pacave Earth Prassure on CoripoiontT kcensdenng passive earth presure sing on component t [cooiert of passive ert pressure = K™ 8737 erate passive eat pressure = 12189 KN? 42.163 ume Ircterof safety forgassive pressure = 2.000 passive force actng = seat ial : szzt Resisting Memert = $6240 km 1495 ton Maximum Overturning Moment : saskum 082 tm eight of Components and momonts of components about fy EL 8 TAT Wait [coe oman a a a ee A Poo [oie] 5080 Tore [aaa See aoe OTC oer to.z60 re T7 79 wit o Precast stab 24820. 6s ‘Tota Resisting Moment - 42.469 48 4248 tm ——Notconsdaing the ‘Stabilly of Drain “Te eaiis stable agar overuming 35 wel 2s stang overturning Resisting Moment 12483 kik (veruring Memert ‘48 km Facto of safety agalast overturalng = Resisting moment Overtuning moment . zat = Safe against Overturning nome is equiesfrsabising the dein mee kB 18008 = 254 wm stiaing Hodartatore stems : 102844 CONSULTING Desa trax Cover for Mounted Umea an @cousuzns so of rn & Oran Cover for Muna tia Resisting force ~ OSayrealiace * Pessvotoea’ Nt cnateing te walt pact aad 40.418 WN = Check ee sting Resisting fore Heron Force 1017 Safe against Sliding Pressure at Bottom et Momant . 15.30 km Goring te governing moment erica ree : 24820 4N | {isto pain of applostion ef resutant om a : 055 m | Eecentety = 215m — 118.000 me Pressure at toe = wits ee) = 655 Nin? Pressure at tog = Win'- ore) =a Wn? zeta 855 j ; nd ence BM ath ton a mn | Ccnstanie : oor ‘ oo = ‘ao Revie aa { peas = ae | Oey = oer | Deh egens 8720 an | Teal deo ponies 12000 om | Etec Dept proaed neon | cone stm > ates) on i eso i ‘Ao stetroqurnd yey 220000 nt | Mona ore ea 9 pe RC aa { Minune ose equ = 19020 at | Provide cen for au ; a 3 Sracgeque ——254 frac pevaes Hey Lalas proved asoans 5 3810 nt Porat f sero roves ah j > ato nt oe ok Te rHtonei of camer tne fo ceuse 7728 f RG 702000 | Runfercemont ontop face | “Mirnirwum reiforoement = 69.600 mm? / fs 1980 ma? | Prove ret vere oat ‘a 2 | facing raved me ‘Seca prone ES | tare pron erste i Distbution reinforcement _ ‘erage do ‘udol ttenetocamet sin de f : 025xPov le ; ' oe ae ° i oa Ssecrgrowies hp spacing pedes 309 cousuurine ‘Desian forshenc force ‘Shear fore tice per m wid fective ickness of baso lb tcetance Design shear sess Percentage of tense re. Provided Peimissle shear sess ‘rom abl 128 of RC 24-2000, estan. wall 1 Basin fer bsnding moment Nat th base ‘BM duo lo felon of lab s0200/2 x05x oe 50 Design BM Constants © t Revere jens eta} Depth rquted ‘ob dep provides Eecbve Dest provided ‘Ares of stot required (id) ner area of ste! 38 per RC Minimum aoa of sic raxueed Design of Dain & Draln Cover for Mounta roid ein fr bending om bate ‘de spacing roqured spacing roides total ea provided so 350 1 200 meio 0 percetage of tense ein provided Hot re Ditibvten reroicement “Tks of wal tbat ‘ea of dition setoronent 190.25 Proved man ste! lata of bars spacing requed spacrg rovices ce Vertes reiforcement: nar fa ‘mmm vercatrefocement= Provide ein for bending ao specing rogues spacing proves tot ares provided Design of vertical wall 2 Ossi forbending moment ves a Baa he bose BM due to totn of slab 0 Dosgr BM ‘constants e con beth ad ef retaing wel art 122 00: 167552 1020/2 x05x oe 204 Kw 41600 mm acs Nin? 026 Nine? 02 Nee? . 0a Ok 140m 201 aN anim | 907 240.00 ‘000 a2 , | 098 f os? 7428 am 9000 - mm 11800 mm 7428 nm Hence ok ase ont on % 19020 ment 206.10. ont 020 14382 nt Hence 0 ona 41600 om 19620 mn? a7 a em ram 200mm 69.500 mn? 41950 mnt | 67580 me 69600 mt Hence ok | 516 231 7a? ee

You might also like