Professional Documents
Culture Documents
MODEL
VOLUME
SIGN
Low
2.6
550
800
222
960
880
0
-
60
60
62
40
39
37
41
40
38
Under 9.0A
10M1 or more (DC500V megger)
AC 1500V 1 minute
Non-woven fabrics filter Efficiency: ASHRAE colorimetric method 65%
Starting current
Insulation resistance
Dielectric strength
HE filter (Option)
Characteristic curve
500
400
Extra High
*Attention
300
High
Low
200
100
200
400
600
800
1000
1200
(m3/h)
0
50
100
150
200
Air volume (L/s)
250
300
350
SPECIFICATIONS
DATE
15-May-05
TYPE
MODEL
NUMBER
P. 11/19
1/4
EA outlet
OA intake
250
250
Duct attachment
250
250
150
155
RA
(return air)
Damper plate
50
660
25
Heat exchanger
(Lossnay core)
HE FILTER
(Option)
1480
Cable
SA
(supply air)
638
250
445
256
SA outret
Air filters
30
155
Control box
RA duct cover
Cable
Maintenance panel
610
95
137 161
30
OA
(outside air)
800
EA
(exhaust air)
*Attention
UNIT
SCALE
mm
N.T.S
1. If condensation is expected to dorm, the insulated ducts should be used dor OA/EA pipes.
2. Effective area od SA opening : 990cm2
3. Effective area od RA opening : 595cm2
DATE
15-May-05
TYPE
MODEL
NUMBER
P. 12/19
2/4
Schematic
Power source
-50Hz 220V
TM1
L
CN8-2
RED
CN8-1
BROWN
BLACK
GREY
YELLOW
CN10
N
BLACK
Breaker
TR
High
SW4
RED
(Supply fan)
ORANGE
BLUE
M2
WHITE
E. High
WHITE
WHITE
CN1
High
SW3
YELLOW
RED
(Exhaust fan)
ORANGE
BLUE
M1
WHITE
E. High
CN7
RED
GM
RED
ORANGE
BLUE
WHITE
CN9
C
BROWN
LS
CN2
BROWN
SW2
SW1
TM3
10
X7
TH1
(OA)
TH2
(RA)
BLACK
CN5
GREY
BLACK
GREY
BLACK
BLUE
BLACK
BLUE
ORANGE
ORANGE
Control box
8
X8
7
CN6
TM2
Transmission
line
12V, 24VDC
Mr.SLIM
(non-polar)
1
Transmission line
(non-polar)
External
control input
1
Tr
an
sm
iss
ion
lin
Timer control
(a-contact)
*Attention
Main unit
(second)
Remote control switch
Mark explanation
MARK
M1
M2
C
GM
LS
TH1
TH2
SW1
SW2
SW3
SW4
NAME
MARK
NAME
TM1
Terminal block (power source single phase 220V)
TM2
Terminal block (Transmission line and external
control input of the Lossnay)
TM3
Terminal block (Monitor output)
TR
Control circuit transformer
X7
Relay contact (For operation monitor output)
X8
Relay contact (For malfunction monitor output)
Exhaust fan
Supply fan
Capacitor
Motor for Bypass movement
Microswitch
Thermistor for outside air
Thermistor for return air
Switch (main/sub change)
Switch (test-movement)
E. High-High select switch (exhaust fan)
E. High-High select switch (supply fan)
SCHEMATIC
DATE
15-May-05
TYPE
MODEL
NUMBER
P. 13/19
3/4
NC Curves
50Hz
Background noise : 25dB or less (A range)
Measurement site : Anechoic chamber
Operation conditions : Lossnay ventilation
1.5m
Measurement
point
90
Extra-high
High
Low
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
10
NC-20
NC-10
63
125
250
500
1k
2k
4k
8k
NC CURVES
DATE
15-May-05
TYPE
MODEL
NUMBER
P. 14/19
4/4