Producto: TRACK-TYPE TRACTOR
Modelo: D6N TRACK-TYPE TRACTOR ALY
Configuracin: D6N XL, D/S, LGP TRACK-TYPE TRACTOR ALY00001-UP (MACHINE) POWERED BY 3126B Engine
Operacin de Sistemas
561N, 572R and 572R Series II Pipelayers and D10R, D11R, D5M, D5N, D6M, D6N,
D6R, D6R Series II, D7R, D7R Series II and D8R Series II Track-Type Tractors
Power Train Electronic Control System
Nmero de medio -SENR8367-17
i02005138
Illustration 1
g00279578
The electronic control module (ECM) is the main component of the Power Train Electronic
Control system. The ECM makes decisions based on input information and memory information.
Then, the corresponding response is made through the outputs. The inputs of the ECM and the
outputs of the ECM are connected to the machine harness by two connectors. Both connectors
have 40 contacts. The ECM is located on the bottom of the left console near the operator seat.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 21/11/2014
Pgina 2 de 8
There are no visual indicators on the ECM. Information for the Power Train Electronic Control
System is shown on the Caterpillar Monitoring System. The ECM sends the information to the
Caterpillar Monitoring System on the CAT data link.
Table 1
Contact Description Of Connector J1 (1)
For The Electronic Control Module (Power Train)
Active (2)
State
No.
Type
Function
Power
+Battery
+Battery
Power
+Battery
+Battery
Power
+Battery
40
Ground
Ground
Ground
Ground
Ground
Ground
Ground
Switch/Sensor Return
Ground
15
Ground
Switch/Sensor Return
Ground
16
Ground
Solenoid Return
Ground
Input/Output
Input/Output
Input
Harness Code 0
Input
Harness Code 1
Input
Harness Code 2
Input
Harness Code 3
Input
Harness Code 4
Input
Ground
30
Input
Floating
24
Input
Ground
20
Input
Floating
29
Input
Ground
23
Input
Floating
35
Input
Ground
21
Input
Floating
38
25
Varies by
machine:
See Table 1
26
32
36
14
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 21/11/2014
Pgina 3 de 8
Input
Ground
19
Input
Floating
13
Input
Ground
37
Input
+Battery
34
Input
Floating
22
Output
On/Off
Output
Proportional (3)
Output
Proportional (3)
10
Output
Proportional (3)
17
Output
Proportional (3)
11
Output
Proportional
12
Output
Proportional
18
Not Used
Not Used
27
Not Used
Not Used
28
Not Used
Not Used
31
Not Used
Not Used
33
Not Used
Not Used
39
(1)
The actual usage of a connector contact depends on the machine. For Example, on the D10R and the D11R, there
is not an Auto Kickdown Switch. Therefore, J1-37 is not connected to a component.
(2)
The ECM responds to an active input only when all the necessary conditions are satisfied.
(3)
This output can be the proportional or the On/Off type. For the D5M, D6M, D6R Series II, D7R Series II, 572R
Series IIand the (D8R Series II) the output is the proportional type. For the D10R and the D11R, the output is the
On/Off type.
Table 2
Contact Description Of Connector J2 (1)
For The Electronic Control Module (Power Train)
Active (2)
State
No.
Type
Function
Ground
Solenoid Return
Ground
Input
PWM
11
Input
PWM
Input
PWM
18
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 21/11/2014
Pgina 4 de 8
Input
PWM
Input
PWM
Input
PWM
10
Input
Engine Speed
Freq
38
Input
Freq
29
Input
Freq
23
Input
Freq
24
Input
Freq
35
Input
Freq
36
Input
Freq
30
Input
Freq
20
Input
Freq
14
Input
Freq
25
Input
Freq
31
Output
On/Off
Output
+8V
12
Output
Backup Alarm
On/Off
37
Output
On/Off (3)
Output
Output
Output
Output
Ground
34
Output
Ground
22
Output
Ground
40
Output
Ground
28
On/Off
17
Output
Proportional (4)
Proportional (5)
Proportional (5)
2
19
13
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 21/11/2014
Pgina 5 de 8
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
21
Not Used
15
Not Used
26
Not Used
27
Not Used
32
Not Used
33
Not Used
Not Used
39
Not Used
16
(1)
The actual usage of a connector contact is machine dependant. For Example, on the D10R and the D11R, there is
not a solenoid valve on the priority valve. Therefore, J2-7 is not connected to a component.
(2)
The ECM responds to an active input only when all the necessary conditions are satisfied.
(3)
With the priority solenoid valve ON, the low pressure oil system is at NORMAL pressure. With the priority
solenoid valve OFF, the low pressure oil system is at HIGH pressure
(4)
This output can be the proportional or the On/Off type. For the D5M, D6M, D6R, D7R and the 572R, the output
is the proportional type. For the D10R and the D11R, the output is the On/Off type.
(5)
Inputs
Numerous inputs inform the ECM of the status of the conditions of the machine. Two types of
inputs exist. There are switch type inputs and sensor type inputs. Switches provide an open signal,
a grounded signal, or a +battery signal to the inputs of the ECM. Sensors provide a signal to the
ECM that changes in a proportional manner in order to reflect changing machine conditions. The
inputs are listed on the Contact Description charts.
Outputs
The power train ECM responds to decisions by sending electrical signals through the various
outputs. The outputs are pulse width modulated (PWM). The ECM operates the PWM outputs in
an on/off manner or in a proportional manner. This depends on the requirements of the output
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 21/11/2014
Pgina 6 de 8
device. The outputs either create an action or the outputs provide information. The outputs are
listed on the Contact Description charts.
Input/Output
The CAT data link is bidirectional. The ECM can receive information and the ECM can send
information. The data link communicates with other electronic control modules on the machine.
The data link also communicates with service tools. The communication permits information to be
shared. The data link is not a visible component. The data link consists of internal ECM circuits
and the connecting harness wiring. For more information, see System Operation, "CAT Data
Link".
Illustration 2
g00858662
Table 1
Power Train Configuration Harness Code
ECM Connector Contact
Wire Identification
Harness Code Plug Contact
(Pin #)
Harness Code Circuit Name
J1-14
J1-36
J1-32
J1-26
J1-25
J1-15, J1
-16
280BK
279BK
278BK
277BK
276BK
G939-PK
(Gnd)
6
Ground
Status
Open
Open
Open
Open
Ground
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 21/11/2014
Pgina 7 de 8
Ground
Open
Differential Steer
Electronic Clutch Pressure
Control
Power Shift Torque Converter
(Such as: DS D6R and D7R)
Differential Steer
Electronic Clutch Pressure
Control
Power Shift Torque Converter
(Such as: D6R Series II, D7R
Series II, D8R Series II)
Lever and Pedal
Electronic Clutch Pressure
Control
Power Shift Torque Converter
572R Pipelayer
Finger Tip Control and Pedal
Electronic Clutch Pressure
Control
Power Shift Torque Converter
572R Pipelayer
Ground
Open
Ground
Open
Ground
Ground
Ground
Ground
Open
Ground
Ground
Open
Open
Open
Open
Ground
Ground
Ground
Ground
Ground
Ground
Ground
Ground
Open
Open
Open
Open
Ground
The power train harness code plug informs the ECM of the configuration of the power train for the
machine. The harness code plug is connected to the five inputs to the ECM. The inputs are J1-25,
J1-26, J1-32, J1-36 and J1-14. The operation of the ECM corresponds to the state of the harness
code inputs. The harness code plug opens a combination of the harness code inputs and the
harness code plug grounds a combination of the harness code inputs. The ECM interprets the
status of the five inputs.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 21/11/2014
Pgina 8 de 8
Note: The ECM requires the identification of the machine in order to determine the application
number of the machine. The ECM receives a machine code from the Caterpillar Monitoring
System or the implement ECM through the CAT data link. A harness code plug that is connected
to the Caterpillar Monitoring System or the implement ECM defines the machine information for
identification. For more information, refer to System Operation, RENR2014, "Caterpillar
Monitoring System".