Air Cooled Heat Exchanger


1.0Introduction to Air Cooled Heat Exchanger

3rd Annual Global Forum


prosperoevents.com

Pipeline Maintenance and Integrity. Management, 23-25 Sep 2015, Berlin

DesignCalcs
API 5L Tube supplier
Prestiti Inpdap 2015
Thermal Flow Sensor Die
2015 Oil Price Forecast
Prestiti fino a 80.000
Ekstrms Vrmetekniska AB
AltonaLab SCADA 49
trace heating tapes
This kind of heat exchanger are used in petrochemical and refineries to utilize the
atmospheric air to cool the hydrocarbon, process and utility fluids by means of indirect
heat transfer from fluid (within the tube) to be cooled by air being circulated by means
of forces / induced draft fan. In order to increase the heat transfer area, fins are also
attached to the periphery of tubes. These heat exchangers are generally designed,
inspected and tested as per API661 standard.
These exchangers are similar to the radiator of a motor car. The air cooled heat
exchangers are mainly used where the heat load is very high and conventional heat
exchanger becomes extremely big with large water requirement. By using air cooled
heat exchanger, water requirement reduces drastically and cooling tower size comes
down. The air coolers are of very large size as the heat transfer co-efficient with air is
very low. Due to the large size, they are mounted on top of the pipe rack to save space.

tosearchtypeandhitenter

FOLLOW US ON GOOGLE+

BEX GmbH
bex-europe.eu

Sprhdsen, Nozzles, Buses,


Boquillas,Ugelli

Heat transfer software


Pneumatic air tube
system
Chiller City Corporation
Camps Bay Hotel
Hydraulic Air Oil Cooler
Thermal Break Pads
Arlon SFT
Geothermal Installation
The best pin bone
remover

Piping engineering
Segui

2.0Types of Air Cooled Heat Exchanger


There are three types of air cooled heat exchanger:

+1

+ 416

a) Forces Draft
b) Induced Draft
c) Natural Draft (used for applications like transformer oil cooling)
The outline sketch and components are as identified in figure 1A & B.

SUBSCRIBE UPDATES. IT'S FREE!


Your email:
Enteremailaddress...

Subscribe

3.0Definitions used forAir Cooled Heat Exchanger


The general terms used for air cooled heat exchangers are defined below:
a) Bank
A bank is one or more bays including one or more items arranged on a continuous
http://www.pipingengineering.com/aircooledheatexchanger.html

RELATED READING
Design Guide For Heat Exchanger
Piping Table of contents: 1. General 2.
Types 3. Definitions a)
1/15

18/7/2015

AirCooledHeatExchanger

structure.
b) Bare tube surface
Total area of the outside surface of the tubes in sq. meter.
c) Bay

Nozzle loads Part 2 <<Nozzle loads


part 1 1.1 Proprietary Equipment
Various Mechanical equipments
Nozzle Loads Part 1 Nozzle Loads
1.0Introduction to Nozzle Loads This
post specifies the

A bay is one or more tube bundles serviced by two or more fans and that include
structure, plenum and other attendant equipment.
d) Finned Surface

Pipingengineering

The finned surface of a tube is the total area of the outside surface of fins exposed to
air.
e) Forced Draft exchanger
This is the one designed with the tube bundles located in the discharge side of the fan.

7,485likes

LikePage

Share

Bethefirstofyourfriendstolikethis

f) Induced Draft exchanger


This is the one designed with the tube bundles located on the suction side of the fan.
g) Tube bundle

Or reach me on aj@pipingengineering.com

This is an assembly of headers, tubes and frames.


Refer figure 1A, 1B, 2, 3, 4, 5 and 6 to understand the above definition.

4.0Content of Enquiry Documents (Special Requirements)


The enquiry documents shall specify any special requirements concerning location of
airflow, any obstruction to airflow and other heat sources.

5.0 Vendors Responsibilties


The vendors proposal shall include the following:
a) A proposal drawing showing major dimensions in plan, elevation, nozzle size and
orientation
b) The proposal shall state whether the vertically mounted electric motors are to be
shaft up or shaft down.
c) It should show the supporting arrangement of the tube bundle / plenum, fan and
fan drive assembly.
d) It should show the relation of the tube bundle part of the bay with respect to the
plenum to depict the movement of the nozzle installed on inlet and outlet headers.

Popular

Recent

Comments

Nozzle Orientation Drawing


August 12, 2014

Tank farm: Types, Design Considerations,


Plot Plan Arrangement, Dyke EnclosurePart 1
August 6, 2013

Piping Layout Drawings Abbreviations and


Legends
February 21, 2013

Elbow: Component for Piping Direction


Change
January 29, 2014

Guide to Level Instruments Principles &


Application
October 19, 2014

Google+

e) It should show the platform and ladder for accessibility, operatibility and
maintenance of fan, drive assembly and piping hooked up to the nozzles located on the
inlet and outlet header.
f) It should show the weight of components, part of fan and drive assembly to derive
the lifting beams, monorail and hoist arrangement to be permanently installed for
maintenance of such components.
g) The supporting column shall be located such that it matches the supporting
structure to house the air cooled heat exchanger e.g. pipe rack or building structure.
h) Allowable nozzle loading standard or data must be furnished to meet the same
during detailed engineering.
i) The fixed point of the tube bundle shall be defined such that the inlet nozzles (hot
fluid side) experience minimum movements in comparison to (cold fluid side) outlet
nozzle to maintain the nozzle loading within allowable limits.
j) In order to achieve the smooth movement of the tube bundle headers and
nozzles over plenum, a friction between the tube bundle and plenum must be means
of providing smooth surface such as Teflon pads, stainless steel plate, graphite pads or
similar material which can withstand the system temperature and compressive load of
component at support.

http://www.pipingengineering.com/aircooledheatexchanger.html

2/15

18/7/2015

AirCooledHeatExchanger

6.0Approvers Responsibilities
The approver shall approve following information received from vendor :
1. Maximum and minimum design temperature.
2. Overall dimensions.
3. Dimension and location of supports.
4. Nozzle size, rating, facing, location, projection, allowable movements and loading on
nozzle (forces and moments).
5. Weight of components for erection and maintenance.
6. Drive mounting details.
7. Screen platform and ladders.

7.0Design
a) Tube bundle design
i) A tube bundle shall be rigid, self contained and designed for handling as a
complete assembly.
ii) Provision is required to be made by vendor to accommodate thermal expansion
of tubes.
iii) All tubes are supported by vendor to prevent sagging or deformation of fins.
iv) A hold-down member (tube keeper) is provided at each tube support, hold-down
members are attached to side frame by bolting.
v) Tubes of single pass cooler are sloped towards the outlet header.
vi) Tubes of multiple pass coolers may not be sloped.
vii) The exchanger may be designed for an internal steam out operation at the
temperature / pressure specified by the process licensor.
b) Heating coils
i) Heating coils are provided to protect the process tube bundle against freeze up
and are provided in the bundle separate from the process bundle.
ii) Heating coils to cover the full width of process tube bundle.
iii) Heating coils are normally single pass type.
c) Headers
i) Provisions are made in the design of header, to prevent excessive warpage of
tube sheets and leakage at tube joints. Any alternative operating conditions including
low process flow at low ambient air temperature, freezing of fluids in tubes, steamout,
stoppage of fan due to power failure, any cyclic conditions must be included by the
vendor in the analysis if specified by the designer.
ii) When the fluid temperature differential between inlet of one tube pass and the
outlet of adjacent tube pass is higher than 110degC then split header construction with
U tubes or other method of restraint relief shall be employed.
iii) If the fluid temperature difference between inlet and outlet of multipass bundle
exceed 110degC, the need of restraint relief shall be insisted.
iv) The cover plate header designer shall permit removal of cover without disturbing
header piping connections. This helps in providing access to tubes during maintenance
http://www.pipingengineering.com/aircooledheatexchanger.html

3/15

18/7/2015

AirCooledHeatExchanger

and repairs.
v) The bonnet header design shall permit removal of bonnet with minimum
dismantling of header piping. This helps in access to the tubes during maintenance and
repairs.
vi) Plug header are equipped with threaded plug holes provided opposite to the ends
of each tube for access. This helps in providing access to the tubes during maintenance
and repairs without disturbing the header as well as piping.
d) Nozzle and other connections
i) All connection 1 and larger shall be flanged
ii) In hydrogen service all connections shall be flanged and slip on flange shall not be
used.
iii) Where design conditions require class 900 or higher flange rating, all connections
shall be flanged.
e) Maximum allowable moments and forces for nozzle and headers
i) In corroded condition each nozzle shall be capable of withstanding the
simultaneous application of the forces of the forces and moments as defined in
Annexure A.
Annexure-A
ii) The sum of nozzle on a single header will consist of components that do not
exceed Mx of 4500 ft.lbs, My of 6000 ft.lbs, Mz of 3000 ft.lbs and Fx of 2250 lbs, Fy of
4500 lbs and Fz of 3750 lbs. The application of the forces and moments as per
Annexure A will cause movement that will tend to reduce the loads to the values given
above.
iii) The total of all nozzle loads on one multi bundle bay shall not exceed 3 times
allowed for a single header.
f) Air side design
The environmental factors such as weather, terrain, adjacent building and equipment
will influence the air flow and hence performance of an air cooled heat exchanger for
fan dispersion angle refer figure 3.
g) Drive arrangements
Refer figure 3 and 7 for typical drive arrangement for air cooled heat exchanger.
h) Design loads
i) Thermal forces shall include all forces due to partial or complete anchorage of
piping or equipment, friction from sliding or rolling of equipment, and forces from
expansion or contraction of structure.
ii) Nozzle load shall include all forces and moment applied to the nozzle face
including the dead weight of pipe, thermal forces and the weight of fluid in the piping.
i) Mechanical Access facilities
i) The number and location of header access platform interconnecting walkways
and ladder shall be specified in enquiry specification during detailed engineering.
ii) Maintenance platform shall be provided beneath each drive assembly for easy
access to drive and for removal and replacement during maintenance of all drive
components. The platform shall be provided all around the drive assembly.
iii) Ladder, Railings, toe plates and safety chains with safety bolts etc. shall be
provided for platform as per good engineering practice.
iv) Header shall be provided with toe bone or knee railing on the side next to the
exchanger.

http://www.pipingengineering.com/aircooledheatexchanger.html

4/15

18/7/2015

AirCooledHeatExchanger

8.0Design Features ofAir Cooled Heat Exchanger


Air cooler consist of tubes, header boxes, fan, motor and sometimes louvers. Tubes are
all placed in number of horizontal layers and both ends of the tubes are welded in the
rectangular header box. This is similar to tube sheet of conventional heat exchanger.
The piping gets connected to nozzles of this header box. Typical drawing of above
arrangement is attached here with (refer fig. 2, 5, 6) these header boxes are supported
on steel frame. The fan is provided below the tube bundles in force draft arrangement.
The fan is provided above tubes in induced draft arrangement.
Following different type of constructions are generally available:
a) Singlepass Cooler.
b) Multipass Cooler.
c) U tube Coolers
In a single pass and multipass cooler with odd number of passes, the fluid enters from
one end of the header box and leaves at the other end of the header box.
In multipass with even number of passes and U tube, the fluid enters and leaves from
the same end of the header box.
The following general design featured shall be taken into account from equipment
layout/piping layout point of view.
8.1 The tube bundle has a provision to move in lateral direction + 6 mm or 13mm in
one direction. This movement is required for accommodating piping header
movement. In case additional movement is required due to piping, needs to be
specified during enquiring stage. This is shown in figure 1.
8.2 The tube expands in longitudinal direction and normally a provision is made
such that the inlet header side is a fixed side and tube expands in the other direction.
http://www.pipingengineering.com/aircooledheatexchanger.html

5/15

18/7/2015

AirCooledHeatExchanger

9.0Consideration from Equipment Layout Point of View


9.1 This equipment requires smooth air flow for cooling purpose hence the
location of the equipment should be such that it is not closely surrounded by
equipment or structure which blocks the air flow path.
9.2 To give a better air flow, this is installed on the top of the pipe rack, or
structure so that there is no obstruction to reduce air flow. At the same time by
installing on top of the rack, the space on the ground can also be saved and the plant
becomes more compact.
9.3 Normally tube bundle length is fixed based on the width of the piperack or
structure so that the supporting legs of air cooler bundle comes on the main beams,
which can simplify the pipe rack design. Also it is preferable to adjust piperack /
structure longitudinal column spacing based on the width of the air cooler bundle so
that legs of bundle straight away sit on top of the column. This may not be possible to
adjust some times as each tube bundle may have varied width depending on service
condition and adjusting piperack columns for different width may not be feasible from
structural design and detailing point of view.
9.4 It is required to provide walkways between two sets of air coolers. This
means say one cooler may consist of 10 bundles and other one of 5 bundles then
walkways should be provided between, after tenth bundle and before starting of next
five bundles. This walkway shall be minimum 1.5 to 2.0 m wide as this will be the only
place at that elevation to store tools and parts during maintenance.
9.5 The air coolers on the piperack shall be located such a way that at least from
one side the bundles are accessible with crane.
9.6 Air cooler should have access platform mounted on the air cooler structure
at least on the operating side. Platform all around is better for maintenance.
9.7 Air coolers have motors hanging at the bottom of the cooler. It is required to
provide access platform underneath the cooler for motor & for maintenance. This
platform can be a localized also.
9.8 To access the air cooler platforms or motor maintenance platform, a regular
staircase is required to be provided.
9.9 Inlet piping of air cooler has a symmetrical distribution and loops as
explained later in this article. This is required to be supported hence either air cooler
structural columns need to be extended upwards to support piping or piperack /
structure columns. This data is required to be given very early in the project as it is to
be considered in piperack design.

10.0Consideration from Piping Point of View


The air coolers are mainly used where very large quantity of vapor is required to get
condensed or very large quantity of gas/ liquid is required to be cooled. The application
is very common in case of column overhead vapor condensation. Following points need
to be taken care while laying air cooler piping.
10.1 Piping distribution to air cooler should be symmetrical from centre line of
complete air cooler assembly.
The typical configuration of inlet piping is shown in Figure 8, 9, 10, 11.
10.2 In case of supply line having very low pressure, care shall be taken to keep
no. of bends to minimum without sacrificing functional and stress requirement. Line
sizing during the distribution should be sufficient, if required check with process
department.
10.3 Length of each branch pipe for all bundles from its header shall be more or
less same to keep pressure drop same and equal distribution of fluids to all bundles.
10.4 Inlet side header box shall be considered as a fixed point (in tube direction)
for piping connection. But the bundle can move in transverse direction of tubes + 6 mm
or if it is fixed at one edge then it can move by 13 mm in the other direction. This
movement is required for piping header expansion compensation. If air cooler is
required to be mounted in eccentric position i.e. to get 13 mm movement in one
direction, vendor shall be informed early enough.
http://www.pipingengineering.com/aircooledheatexchanger.html

6/15

18/7/2015

AirCooledHeatExchanger

10.5 The transverse movement of bundle can occur only when piping connected
to nozzles generate enough force to overcome friction at the bundle support point.
That is why normally at the support point vendor provides S.S plate, PTFE plate or ball
bearings to ease the movement.
10.6 The force due to thermal expansion of piping created on the bundle nozzle
shall be less than the limits given by API 661.
10.7 While doing stress analysis, the following considerations shall be given.
10.7.1 It is ideal to simulate the complete air cooler with tubes, header boxes and
support points in computer program. But most of the time it is difficult, then model air
cooler bundle as a rigid element with total weight of bundle with supports and friction
co-efficient depending on type of supports.
10.7.2 After modeling piping along with each bundle as explained above, the piping
stress analysis to be carried out. During this analysis all the nozzles in longitudinal &
transverse direction to be considered as rigid i.e. anchor. After the analysis, check the
loading on each nozzle. If these loading are within the limits of API 661 there is no
problem. By modeling the air cooler either as rigid element or as a normal equipment,
with weight & support friction, the nozzle loads shown by computer in operating
condition will be taking care of bundle movement. In case nozzle loads on some nozzles
exceed API 661 limits, the configuration of such pipe needs to be modified to reduce
nozzle loads.
10.7.3 In case it is difficult to model air cooler due to some reason, the following
method should be adopted.
Consider all nozzles as anchor points and model complete piping system as usual. Now
do the analysis & find out which all nozzle loads exceeds, the nozzle where load is
exceeding the values of API 661, feed 1 mm nozzle movement to that nozzle and carry
out analysis. This 1 mm movement shall be fed in the direction in which header will try
to move the bundle. If it still does not meet go on adding movement of 1 mm & check
till results are satisfactory. In the first case where nozzle is considered as anchor point,
find out the difference between actual loads & API loads, that will tell whether the
differential loading will allow bundle to move or not with friction factor on support
point. Of course this is a very crude method of analysis and as far as possible should be
avoided unless it is a very small air cooler and nozzle load is not governing the design.
10.7.4 The outlet piping when analyzed, the bundle movement due to inlet piping
should be modeled if analysis for inlet & outlet is not done together. Again nozzle
loading criteria for outlet piping to be met as per API 661.

http://www.pipingengineering.com/aircooledheatexchanger.html

7/15

18/7/2015

AirCooledHeatExchanger

Fig1A Typical Air Cooler Arrangement

http://www.pipingengineering.com/aircooledheatexchanger.html

8/15

18/7/2015

AirCooledHeatExchanger

Fig 1B: Air Cooler Section

Fig 2: Typical Bay Arrangement

http://www.pipingengineering.com/aircooledheatexchanger.html

9/15

18/7/2015

AirCooledHeatExchanger

Fig 3: Fan Dispersion Angle

Fig 4: Typical Plenum Arrangements

http://www.pipingengineering.com/aircooledheatexchanger.html

10/15

18/7/2015

AirCooledHeatExchanger

Fig 5: Typical Construction of Tube bundles with Removable Cover Plate and
Removable Bonnet Headers

Fig 6: Typical Construction of a Tube Bundle with Plug Headers

http://www.pipingengineering.com/aircooledheatexchanger.html

11/15

18/7/2015

AirCooledHeatExchanger

Fig 7: Typical Drive Arrangements

11
Mipiace

Tweet

Fig 8: Air Cooler Inlet Piping Various options

http://www.pipingengineering.com/aircooledheatexchanger.html

12/15

18/7/2015

AirCooledHeatExchanger

Sign up to get latest FREE articles right to your inbox!

Your email:
Enteremailaddress...

Subscribe Unsubscribe

Fig 9: Air Cooler Outlet Piping Various Options

Fig 10: Air Cooler Pigtail Configurations Various Options

http://www.pipingengineering.com/aircooledheatexchanger.html

13/15

18/7/2015

AirCooledHeatExchanger

Fig 11: Air Cooler Pigtail Configurations Various Options


Related Posts:

Design Guide For Heat Exchanger Piping Table of contents: 1. General 2. Types 3.
Definitions a)
Nozzle loads Part 2 <<Nozzle loads part 1 1.1 Proprietary Equipment Various
Mechanical equipments
Nozzle Loads Part 1 Nozzle Loads 1.0Introduction to Nozzle Loads This post
specifies the
Cooling Tower: Heat Transfer Equipment in Process Industry 1.0Introduction to
Cooling Tower: Cooling Tower is the most common
Check List (Piping) Project Start/ Kick-Off Meeting Sr. No. List REVIEW/ QUERIES
ON DOCUMENTS RECEIVED FROM CLIENT/
SharethisonWhatsApp

LEAVE A REPLY
Your email address will not be published. Required fields are marked *
Name *

Email *

Check here to Subscribe to notifications for new


posts

PostComment

Confirm you are NOT a spammer

http://www.pipingengineering.com/aircooledheatexchanger.html

14/15

18/7/2015

AirCooledHeatExchanger

copyright Piping-engineering 2015 All Rights Reserved. Privacy Policy | About Us

http://www.pipingengineering.com/aircooledheatexchanger.html

15/15

You might also like