Industrial Wireless

Wireless from the sensor


to the network

Our Industrial Wireless products


for your automation infrastructure
Phoenix Contact is a leading international
supplier for automation infrastructure.
Industrial Wireless products from Phoenix
Contact provide reliability and security for
the transmission of data and signals.
Wireless systems enable you to easily and
efficiently negotiate the many challenges
faced in an industrial communication
infrastructure.
Wireless systems for all
interfaces
Our comprehensive product range
offers flexible options for implementing
wireless industrial communication
solutions. Suitable wireless systems
are available for a wide range of
interfaces.

The advantages of industrial wireless


systems at a glance:
Flexibility, easy installation, and
cost savings compared to cable-based
installations
Bypassing of obstacles
Alternative to slip rings that are prone to wear
and cable lines on mobile devices
Reduced maintenance costs
Monitoring and control of remote
stations with no cable access

Wireless I/O
Digital signals
0 ... 250 V AC/DC
Analog signals
0 ... 20 mA, 4 ... 20 mA
0 ... 10 V, HART

PHoeNIX CoNTACT

Table of contents
Areas of application
4/5
Wireless technologies
6/7
Wireless I/O
Trusted Wireless I/O
Bluetooth I/O

8 11
12 15

WirelessHART

16/17

Mobile phone I/O

18 / 19

Wireless Serial
Trusted Wireless Serial

20/21

Bluetooth Serial

22/23

WLAN Serial

24/25

Mobile phone Serial

26 / 27

Wireless Ethernet
Industrial Bluetooth

28/29

Industrial WLAN

30 / 31

Mobile phone Ethernet

32 / 33

Accessories
34 43

Wireless Serial
Wireless Ethernet

PHoeNIX CoNTACT

Industrial Wireless in

Process technology
Process technology systems often
feature widely distributed outdoor
system structures. Therefore it is often
only possible to acquire I/O data such
as temperatures and fill levels at great
effort, since the distance to be covered is
so great or the terrain is inaccessible.
For the implementation of such systems,
it is therefore systems with integrated
repeater functions,

System expansion
and post installation
Acquisition of data from distributed
or difficult to access sensors

PHoeNIX CoNTACT

which are particularly suitable for


creating linear or tree structures,
that are primarily used. The devices
that are used feature extended ambient
temperature ranges and approvals for
use in potentially explosive areas. Since
the values of sensors only ever change
slowly, low transmission speeds are
used, thereby enabling long distances
to be covered. With modern wireless

technology, fieldbus systems can also be


transmitted in addition to I/O signals,
e.g., to replace slip rings in wastewater
technology.

... production automation


In contrast to process technology
systems, systems used in production
automation are often physically restricted
in terms of space.
The distances to be covered are usually
several hundred meters. The applications
are highly dynamic and fast roaming
methods must be supported so that it
is possible to switch between various
system parts.

The controllers and floor conveyor


vehicles that are connected wirelessly
require large volumes of data in a short
amount of time, which is why WLAN
technology is used for these applications.
Another field of application is the
replacement of hose packs that are
susceptible to interference on robots
or drag chains. The necessary I/O
information, for example from proximity

switches, is transmitted by means of


wireless technology. At the fixed part
of the system, the wireless signals are
either converted back into discrete I/O
signals or converted into data packets
for an established fieldbus system. As a
result, fast and wear-free transmission
of I/O information in the space of a few
milliseconds is ensured in IP20 and IP65
environments.

Dynamic applications
Fast transmission of large amounts of
data and replacement of components
that are susceptible to interference

PHoeNIX CoNTACT

Wireless technologies

The key requirement for the use of


wireless technologies in industrial
applications is that the technology
must be as robust and reliable as
a cable connection, even under
harsh conditions. With wireless
communication, the data is transmitted
by means of electromagnetic waves

through free space that is not available


exclusively. The wireless connection is
therefore subjected to interference, such
as electromagnetic interference fields,
which can adversely affect transmission.
In addition, reflections, fading,
interference, and shadowing can occur.

Despite the influences described,


Bluetooth, Trusted Wireless,
WirelessHART, and WLAN 802.11
are interference-free thanks to their
particular method of operation.

868 MHz
900 MHz
2.4 GHz
Trusted Wireless 2.0 technology is
specifically designed for the reliable
transmission of data and signals over long
distances.

2.4 GHz

2.4 GHz

Bluetooth wireless technology is standardized


according to IEEE 802.15.1.

WirelessHART technology is standardized


according to IEEE 802.15.4 and is used
for the wireless networking of HART field
devices in the process industry.

Extremely reliable transmission thanks to


redundant transmission channels

Extremely secure transmission protected


against manipulation

High coexistence capability in unfamiliar


wireless environments, parallel operation
of several Bluetooth systems at one
location thanks to efficient frequency usage

High degree of reliability, thanks to fullmesh routing

Properties
High degree of reliability thanks to AES
encryption, frequency hopping method,
and coexistence management
Range of several kilometers thanks to
adjustable data rates
Mesh networks with up to 250 nodes

Very low energy consumption thanks to


time-synchronized communication

Range of up to 200 m
Short delay times

Applications
Wireless I/O:
Analog, digital I/O signals (support
modular expansion)
Wireless Serial:
Serial RS-232, RS-485 data

PHoeNIX CoNTACT

Wireless I/O:
Analog, digital I/O signals
Wireless Serial:
Serial RS-232, RS-422/485 data
Wireless Ethernet:
Ethernet data

Wireless I/O:
Analog HART signals

WLAN IEEE 802.11


2.4 GHz

Mobile phone
3G

5 GHz

WLAN is a wireless standard according to


IEEE 802.11 a/b/g/n for creating wireless
local area networks.

Communication takes place via the mobile


phone networks of the telecommunications
provider.

High data rates of up to 54 Mbps or


300 Mbps

Available in over 200 countries

Fast roaming
Device mobility in wide area networks

2.4 GHz and 5 GHz


worldwide
900 MHz
America
868 MHz
Europe

Use of international mobile phone


standards (GPRS, EDGE, UMTS, HSPA,
etc.)

High degree of reliability, thanks to MiMo


technology

Range: national and global

Wireless Ethernet:
High-speed Ethernet transmission

Wireless I/O:
Analog, digital I/O signals
Wireless Serial:
Serial RS-232 data
Wireless Ethernet:
Ethernet data
Alarm generation:
SMS, e-mail
PHoeNIX CoNTACT

Wireless I/O
Radioline easy startup
with I/O mapping
Radioline is the wireless system for large
systems and networks. Special features
include extremely easy assignment of
inputs and outputs by simply turning the
thumbwheel - without any programming.
Radioline transmits I/O signals as well as
serial data and is therefore very versatile.
In addition, you can implement various
network structures: from a simple point-topoint connection to complex networks.

I/O mapping
I/O mapping simplifies signal distribution
in your system. Assign inputs and outputs
quickly by simply turning the thumbwheel.
In this way you can distribute and multiply I/O
signals freely in your network without the
need for any complex programming.

International
Ex approval
The modules are certified
according to 94/9/EC (ATEX)
directives and can therefore
be used internationally in
potentially explosive areas.

PHoeNIX CoNTACT

868 MHz wireless module

900 MHz wireless module

2.4 GHz wireless module

RAD-868-IFS
Order No. 2904909

RAD-900-IFS
Order No. 2901540

RAD-2400-IFS
Order No. 2901541

Supply voltage:
19.2 30.5 V DC

Supply voltage:
10.8 30.5 V DC

Supply voltage:
19.2 30.5 V DC

Adjustable transmission power of up to


500 mW

Adjustable transmission power of up to


1000 mW

Adjustable transmission power of up to


100 mW

Can be extended with I/O modules via


T-BUS

Can be extended with I/O modules via T-BUS

Can be extended with I/O modules via T-BUS

Extended temperature range:


-40C +70C

Extended temperature range:


-40C +70C

Extended temperature range:


-40C +70C

Antenna connection: RSMA (female)

Antenna connection: RSMA (female)

Antenna connection: RSMA (female)

Approvals: UL 508, HazLoc

Certified according to ATEX directive

For use in North and South America and


Canada

Approvals: ATEX, UL 508, HazLoc, IECEx,


FCC

3.2

2.1

2.2

2.3

3.1

3.2

3.3

+I1
+I2

-I1
-I2

Pwr
Dat

I1
I2

3 3

0 2

Dat

1 3

Dat

7 7

8 8
9 9

DIP-1
P1

Pwr
Dat

Dat
Err

0 3

1 4
2 5

3.2

3.3

+I1
+I2

-I1
-I2

OFF

ON

1
2
3
4

0 5

Pwr

1 6

Dat

2 7

Err

2.1

2.2

2.3

2.1

+24V 0V
+24

2.2

2.3

3.1

DI1L DI1H DI1


DI2L DI2H DI2

RSSI+ RSSI

ANT

DI4

RX TX

D(A)
( ) D(B)
( )
RX TX GND
CO1 NO1 NC1

Pwr3
Pwwr4
r4

DI3L DI3H DI3


DI4L DI4H DI4

+I3
+I4

-II3
-I4

4.2

4.3

9 4

Pwr

*1 56

Dat
Err

1 1

2 2
3 3

Pwr1
Pwr2

3.2

3.3

+I1
+I2

-I1
-I2

OFF

ON

1
2
3
4
1
DIP-1

Pwr
Dat
Err

R
Reset
4.1

4.2

4.3

5.1

5.3

5.2

4.1

0 6

1 7
2 8

0 7

Pwr

1 8

Dat

2 9

Err

DI1
DI2
DI3

DI3

2.1

2.2

2.3

+24V 0V
+24

2.1

2.2

Pwr
Dat
Err

9 1

*1 23

2.3

DI1L DI1H DI1


DI2L DI2H D
DII2

S-P
S-PORT

Pwr

Err

3.1

Pwr1
Pwr2

3.2

3.3

+II1
+I2

-I1
-I2

OFF

ON

1
2
3
4

4.1

RX TX

DI4

D(A)
( ) D(B)
( )
RX TX GND
CO1 NO1 NC1

4.2

4.3

DI3L DI3H DI3


DI4L DI4H DI4

5.1

5.2

5.3

Pwr3
Pwr4

4.1

+I3
+I4

-II3
-I4

4.2

4.3

DI4

D(A)
( ) D(B)
( )
RX TX GND
CO1 NO1 NC1

4.1

4.2

Pwr3
Pwr4

DI3L DI3H DI3


DI4L DI4H DI4

5.1

4.3

5.2

5.3

4.1

+I3
+I4

-II3
-I4

4.2

4.3

2.1

2.2

2.3

+24V 0V
+24

Dat
Err

0 0

1 1
2 2

Pwr
Dat
Err

0 1

1 2
2 3

ANT

Pwr
Dat
Err

9 5

*1 67

DI1

Re
Reset

+II3
+I4

-I3
-I4

4.1

DO3

Dat

3.3

-I1
-I2

ON

1 9

2 0
3 1

4.2

4.3

+I3
+I4

-I3
-I4

4.2

4.3

5.1

5.2

5.3

4.1

4.1

4.1

4.2

4.3

5.1

5.2

5.3

4.1

4.2

4.3

Pwr
Dat

9 0

*1 12

1 1

Dat

2 2

Err

2 3

Err

Point-to-point connection

3.2

U1
U2

RAD-DI4-IFS
Dat
Err

0 2

1 3
2 4

3.3

I1
I2
OFF

Dat
Err

0 8

1 9
2 0

2.1

2.2

OFF

DIP-1

Dat
Err

1 9

2 0
3 1

2.1

2.2

2.3

RSSI+ RSSI

I3
I4

4.1

4.2

COM3 NO3 NC3


COM4 NO4 NC4

2.2

2.3

2.1

2.2

2.3

3.1

3.2

3.3

+I1
+I2

-I1
-I2

Pwr
Dat

5.3

Err

Pwr
Dat
Err

2.2

2.3

2.1

2.2

2.3

3.1

3.2

3.3

+I1
+I2

-I1
-I2

1 6

Pwr1
Pwr2

OFF

ON

1
2
3
4

9 1

0 2
1 3

Dat

0 4

1 5
2 6

Pwr
Dat
Err

0 6

1 7
2 8

2.2

2.3

Err

0 3

1 4

2 5

2.3

DIP-1
1

Pwr
Dat
Err

0 4

1 5

2 6

3.1

3.2

U1
U2

I1
I2
OFF

DIP-1

Pwr
Dat
Err

3.3

ON

1
2
3
4

0 5

1 6

2 7

U3
U4

I3
I4

4.1

4.2

3
4

4.3

DIP-1

Pwr
Dat

0 6

1 7
2 8

3.1

3.2

U1
U2

I1
I2
OFF

DIP-1

Pwr
Dat
Err

3.3

ON

1
2
3
4

0 7

1 8
2 9

5.2

5.3

U3
U4

I3
I4

4.1

4.2

3
4

4.3

2.2

OFF

ON

1
2
3
4

2.3

DIP-1

Pwr
Dat

0 8

1 9
2 0

3.1

3.2

U1
U2

I1
I2
OFF

4.3

2.2

2.3

5.1

5.2

5.3

2.2

2.3

4.1

4.2

4.3

DIP-1

Pwr
Dat
Err

3.3

ON

1
2
3
4

1 9

2 0
3 1

DO1
DO2
DO3
DO4

COM3 NO3 NC3


COM4 NO4 NC4

5.1

2.1

COM1 NO1 NC1


COM2 NO
O2 N
NC
C2

Err

DO4

COM3 NO3 NC3


COM4 NO4 NC4

5.1

2.3

DO3

DO4

5.3

ON

DO2

DO3

5.2

2.2

OFF
1
2
3
4

DO1

DO2

5.1

2.1

COM1 NO1 NC1


COM2 NO
O2 N
NC
C2

Err

DO1

COM3 NO3 NC3


COM4 NO4 NC4

4.3

ON

5.2

5.3

U3
U4

I3
I4

4.1

4.2

3
4

4.3

COM3 NO3 NC3


COM4 NO4 NC4

5.1

5.2

5.3

U3
U4

I3
I4

4.1

4.2

3
4

4.3

3.1

Pwr1
Pwr2

3.2

3.3

+I1
+I2

-I1
-I2

OFF

ON

1
2
3
4
DIP-1

0 0

Pwr

1 1

Dat

2 2

Err

0 1

Pwr

1 2

Dat

2 3

Err

DI1
DI2

DIP-1

Pwr

Err

Reset

2.1

9 4

0 5

RAD-ID

S-PORT

ANT

RAD-2400-IFS

RSSI+ RSSI

Reset

DI1L DI1H DI1


DI2L DI2H DI2

+24V 0V

RAD-AI4-IFS

5.2

RAD-DI4-IFS

5.1

DI3

IO-MAP

4.3

IO-MAP

5.3

5.2

2.1

S-PORT

DO4

U3
U4

2.1

5.1

4.2

RAD-2400-IFS

DO3

DI3L DI3H DI3


DI4L DI4H DI4

RAD-ID

Reset

ANT

DO2

DI4

4.3

I3
I4

4.1

DI1L DI1H DI1


DI2L DI2H DI2

+24V 0V

DO1

DI3

4.2

U3
U4

2.2

OFF
1
2
3
4

2.3

ON

1
2
3
4

Pwr

DI2

4.1

5.3

2.1

COM1 NO1 NC1


COM2 NO
O2 N
NC
C2

COM1 NO1 NC1


COM2 NO2 NC2

1
2

ON

1
2
3
4

Pwr

DI1

D(A) D(B)
RX TX GND
CO1 NO1 NC1

Dat

DO4

5.2

RAD-DI4-IFS

3.1

2.3

RAD-2400-IFS

1 5

RX TX

DIP-1

Pwr

3.3

ON

DO3

5.1

IO-MAP

2.2

DIP-1

Pwr

RAD-ID

9 3

0 4

RAD-AO4-IFS

2.1

DI1L DI1H DI1


DI2L DI2H DI2

S-PORT
Err

IO-MAP

Dat

RAD-DOR4-IFS

2.3

ANT

Pwr

IO-MAP

2.2

RSSI+ RSSI

I1
I2

Star network

IO-MAP

2.1

+24V 0V

3.2

OFF
1
2
3
4

RAD-AO4-IFS
D-

DIP-1
1

3.1

U1
U2

DO2

COM3 NO3 NC3


COM4 NO4 NC4

4.3

2.3

DO1

DO4

4.2

2 4

Err

DO3

4.1

1 3

Dat

DO2

D(A)
( ) D(B)
( )
RX TX GND
CO1 NO1 NC1

ON

0 3

Pwr

DO1

RX TX

2.2

OFF
1
2
3
4

RAD-AO4-IFS
D-

DIP-1
1

1 2

Dat

2.1

COM1 NO1 NC1


COM2 NO
O2 N
NC
C2

0 1

Pwr

3.3

ON

RAD-AO4-IFS
D-

I1
I2

RAD-DOR4-IFS
AD-DOR4-IFS
-D

DIP-1

0 0

Pwr

Re
Reset

Err

3.2

OFF
1
2
3
4

IO-MAP
IO-M
MAP
P

4.3

4.2

3.1

U1
U2

IO-MAP
IO-M
MAP
P

4.1

2.3

ON

RAD-AO4-IFS
D-

RAD-2400-IFS
D-2

S-P
S-PORT

5.3

2.2

OFF
1
2
3
4

RAD-DOR4-IFS
AD-DOR4-IFS
-D

2.1

COM1 NO1 NC1


COM2 NO
O2 N
NC
C2

RAD-DOR4-IFS
AD-DOR4-IFS
D

2.3

RAD-DOR4-IFS
AD-DOR4-IFS
-D

2.2

IO-MAP
IO-M
MAP
P

2.1

RAD
D-ID
D
RAD-ID

5.2

4.2

ANT

5.1

3.2

+II1
+I2
OFF

1
2
3
4

Pwr

Pwr3
Pwwr4
r4

IO-MAP
IO-M
MAP
P

I3
I4

IO-MAP
IO-M
MAP
P

U3
U4

IO-MAP
IO-M
MAP
P

NC3
NC4

IO-MAP
IO-M
MAP
P

COM3 NO3
COM4 NO4

IO-MAP
IO-M
MAP
P

DO4

D(A) D(B)
RX
TX GND
CO1 NO1 NC1

RAD-AO4-IFS
D-

RX TX

RAD-DOR4-IFS
AD-DOR4-IFS
D

-I3
-I4

IO-MAP
IO-M
MAP
P

+I3
+I4

RSSI+ RSSI
SSI

4.3

3.1

Pwr1
Pwr2

Err

DI3L DI3H DI3


DI4L DI4H DII4

RAD-AI4-IFS

Pwr3
Pwr4

DI3H DI3
DI4H DI4

IO-MAP
IO-M
MAP
P

DI4

4.2

2.3

DI4

D(A)
( ) D(B)
( )
RX TX GND
CO1 NO1 NC1

IO-MAP

Re
Reset

Pwr3
Pwr4

+24V 0V
+24

4.1

1 9

2 0

DI3

DI3L DI3H DI3


DI4L DI4H DI4

DO2

DI3

DI3L
DI4L

0 8

DI2

RX TX

DI4

D(A)
( ) D(B)
( )
RX TX GND
CO1 NO1 NC1

DO1

DI2

D(A) D(B)
RX
TX GND
CO1 NO1 NC1

Dat

DI1

DI3

RX TX

2.2

DIP-1

Pwr

Err

DI2

RX TX

DI1

2.1

DI1L DI1H DI1


DI2L DI2H D
DII2

RSSI+ RSSI
SSI

DIP-1

Pwr

Err
R
Reset

Err

Pwr

3.1

Pwr1
Pwr2

DI3

DI2

RAD-2400-IFS
D-2

9 1

Pwr

Err

2 4

2 6

DI2

R
Reset

2 2

Dat

0 2

1 3

2.3

0 4

1 5

DI1

S-P
S-PORT

DIP-1
P1

1 1

Pwr

Err

DI1

RX TX

RAD-ID
RAD
D-ID
D

8 8
9 9

IO-MAP
IO-M
MAP

7 7

Err

RAD
RAD-ID
D-ID

Dat

IO-MAP
IO-M
MAP

Pwr

IO-MAP
IO-M
MAP

RAD-ID
RAD
D-ID

0 1
1 2

IO-MAP
IO-M
MAP

9 0

Err

Dat
Err

R
Reset

ANT

Dat

Pwr

Dat

ON

1
2
3
4

RSSI+ RSSI
SSI

Pwr

9 2

*1 34

2.2

1
DIP-1

Pwr

RAD-AI4-IFS
AD
S

OFF

9 3

*1 45
Re
Reset

RAD-DI4-IFS
AD
S

RAD-2400-IFS
D-2

S-P
S-PORT

DIP-1
1

Err

U1
U2

Err

RAD-AI4-IFS
AD
S

ON

RAD-DI4-IFS
AD
S

S-P
S-PORT

OFF
1
2
3
4

ON

IO-MAP
IO-M
MAP
P

NC1
NC2

ANT

IO-MAP
IO-M
MAP
P

RSSI+ RSSI
SSI

RAD-AO4-IFS
RAD-AO4AD
IFSS

-I1
-I2

ON

1
2
3
4

RAD-2400-IFS
RAD-2400
AD
-IFSS

+I1
+I2

OFF

RAD-AI4-IFS
RA
RAD-AI4IFSS

RAD-DI4-IFS
RA
RAD-DI4IFSS

S-P
S-PORT

RAD-2400-IFS
RAD-2400
AD
-IFSS

COM1 NO1
CO
COM2 NO2

+24V 0V
+2
Pwr1
Pwr2

RAD-DOR4-IFS
RAD-DOR4
R
D-IFSS

DI1H DI1
DI2H DI2

ANT

RAD-ID
RAD
D-ID
D

Dat

RSSI+ RSSI
SSI

OFF
1
2
3
4

IO-MAP
IO-M
MAP
P

Pwr

DII1L
D
DI2L

+24V 0V
+2

Pwr1
Pwr2

1
DIP-1

IO-MAP
IO-M
MAP
P

ANT

RAD-AI4-IFS
AD

DI1L DI1H DI1


DI2L DI2H DI2

RSSI+ RSSI

2.1

DI1L DI1H DI1


DI2L DI2H D
DII2

S-P
S-PORT

2.3

+24V 0V
+24

RAD-2400-IFS
D-2

2.2

3.3

RAD-DI4-IFS
AD
S

3.1

RAD-2400-IFS
D-2

2.3

RAD
D-ID
D
RAD-ID

2.2

IO-MAP
IO-M
MAP
P

2.1

IO-MAP
IO-M
MAP
P

2.3

S-P
S-PORT

2.2

RAD-AI4-IFS
AD

2.1

RAD-DI4-IFS
AD
S

3.3

RAD-2400-IFS
D-2

3.2

RAD
D-ID
D
RAD-ID

3.1

IO-MAP
IO-M
MAP
P

2.3

IO-MAP
IO-M
MAP
P

2.2

RAD
D-ID
D
RAD-ID

2.1

RAD-AI4-IFS
AD
S

2.3

ANT

2.3

RAD-DI4-IFS
AD

2.2

RSSI+ RSSI

2.2

IO-MAP
IO-M
MAP
P

2.1

+24V 0V
+24

2.1

2.1

IO-MAP
IO-M
MAP
P

For use throughout Europe

DI4

RX TX

D(A) D(B)
RX TX GND
CO1 NO1 NC1

Pwr3
Pwr4

DI3L DI3H DI3


DI4L DI4H DI4

+I3
+I4

-I3
-I4

4.2

4.3

3.2

3.3

DI1
DI2

DI1L DI1H DI1


DI2L DI2H DI2

RAD-DI4-IFS

Pwr1
Pwr2

OFF

ON

1
2
3
4

DI4

RX TX

2.1

2.2

2.3

2.1

2.2

2.3

3.1

3.2

3.3

+I1
+I2

-I1
-I2

D(A) D(B)
RX TX GND
CO1 NO1 NC1

DI3L DI3H DI3


DI4L DI4H DI4

Pwr3
Pwr4

+I3
+I4

-I3
-I4

4.2

4.3

4.1

4.2

4.3

2.2

2.3

5.1

5.2

5.3

3.2

3.3

4.1

DIP-1

Pwr
Dat
Err

0 3

1 4
2 5

+24V 0V

DI1L DI1H DI1


DI2L DI2H DI2

RSSI+ RSSI

ANT

S-PORT

2 2

Pwr1
Pwr2

OFF

4.1

4.2

4.3

5.1

5.2

5.3

4.1

RAD-AI4-IFS

0 0

1 1

RAD-DI4-IFS

Dat

RAD-2400-IFS

Pwr

Err

ON

1
2
3
4
DIP-1

DI2

Pwr

DI3

Dat

DI4

Err

Pwr3
Pwr4

+I3
+I4

-I3
-I4

4.2

4.3

9 2

0 3
1 4

Pwr
Dat
Err

Reset

DI3L DI3H DI3


DI4L DI4H DI4

RAD-ID

DI1

D(A) D(B)
RX TX GND
CO1 NO1 NC1

0 1

1 2
2 3

0 5

Pwr

1 6

Dat

2 7

Err

IO-MAP

1 3

RX TX

IO-MAP

9 1

0 2

Reset

Err

IO-MAP

Dat

IO-MAP

Pwr

RAD-ID

S-PORT

ANT

RAD-2400-IFS

RSSI+ RSSI

RAD-AI4-IFS

DI3

+24V 0V

DI1
DI2
DI3
DI4

2.3

2.2

RAD-2400-IFS

9 5

0 6
1 7

2.3

3.1

Pwr1
Pwr2

3.2

3.3

+I1
+I2

-I1
-I2

OFF

ON

1
2
3
4
DIP-1

Pwr
Dat
Err

Reset

Err

0 4

1 5
2 6

Pwr
Dat
Err

0 7

1 8
2 9

2.2

2.3

+24V 0V

DI2

ANT

DI4

4.2

4.3

DI3L DI3H DI3


DI4L DI4H DI4

5.1

2.1

+24V 0V

RSSI+ RSSI

DI3

D(A) D(B)
RX TX GND
CO1 NO1 NC1

4.1

2.1

5.2

5.3

Pwr3
Pwr4

4.1

+I3
+I4

-I3
-I4

4.2

4.3

Pwr
Dat

9 0

0 1
1 2

RSSI+ RSSI

ANT

Pwr
Dat
Err

9 4

0 5
1 6

2.2

2.3

2.1

2.2

2.3

2.1

2.2

2.3

2.1

2.2

2.3

2.1

2.2

2.3

3.1

3.2

3.3

3.1

3.2

3.3

3.1

3.2

3.3

3.1

3.2

3.3

3.1

3.2

3.3

+I1
+I2

-I1
-I2

2.1

2.2

5.1

0 3

1 3
2 4

0 4

1 5
2 6

I1
I2
OFF

1
2

ON

1
2
3
4
DIP-1

Dat
Err

0 3

1 4
2 5

U1
U2

I1
I2
OFF

1
2

ON

1
2
3
4
DIP-1

Pwr
Dat
Err

0 5

1 6
2 7

U1
U2

I1
I2
OFF

1
2

ON

1
2
3
4
DIP-1

Pwr
Dat
Err

0 6

1 7
2 8

U1
U2

I1
I2
OFF

1
2

ON

1
2
3
4
DIP-1

Pwr
Dat
Err

0 7

1 8
2 9

Pwr1
Pwr2

OFF

ON

1
2
3
4

Dat
Err

0 8

1 9
2 0

3.1

OFF

ON

1
2
3
4
DIP-1

Dat
Err

0 4

1 5
2 6

2.1

2.1

RSSI+ RSSI

ANT

Pwr
Dat
Err

9 3

0 4
1 5

3.1

U3
U4

I3
I4

4.1

4.2

3
4

Dat
Err

0 2

1 3
2 4

3.2

3.3

+I1
+I2

-I1
-I2

OFF

ON

1
2
3
4

Pwr
Dat
Err

0 3

1 4
2 5

DI1
DI2

DO1

DI3
DI4

RX TX

U1
I1
1
COM1 NO1 NC1
COM2 NO2 NC2

Pwr1
Pwr2

DIP-1

Pwr

DI2

DO2

D(A) D(B)
RX TX GND
CO1 NO1 NC1

DI1L DI1H DI1


DI2L DI2H DI2

+24V 0V

DI1

RX TX

D(A) D(B)
RX TX GND
CO1 NO1 NC1

DI1L DI1H DI1


DI2L DI2H DI2
UL1 +I1
-I1

Pwr

Dat

1 9

2 0
3 1

4.1

4.2

4.3

4.1

4.2

4.3

4.3

4.1

4.2

4.3

D(A) D(B)
RX TX GND
CO1 NO1 NC1

4.1

4.2

4.3

DI3L DI3H DI3


DI4L DI4H DI4

5.1

5.2

5.3

Pwr3
Pwr4

4.1

+I3
+I4

-I3
-I4

4.2

4.3

DI2
DI3
DI4

COM3 NO3 NC3


COM4 NO4 NC4

5.1

2 5

DI1

DO4

5.3

Pwr

Err

DO3

5.2

0 3

1 4

DIP-1

Pwr

DO2

DO4

DI1L DI1H DI1


DI2L DI2H DI2

RAD-AI4-IFS

U1
U2

Pwr

DO1

DO3

1
2

ON

DIP-1

Err

RAD-DI4-IFS

ON

DIP-1

Dat

RAD-AO4-IFS

OFF
1
2
3
4

Pwr

RAD-AO4-IFS

COM1 NO1 NC1


COM2 NO2 NC2

Err

DO2

COM3 NO3 NC3


COM4 NO4 NC4

5.1

RAD-AO4-IFS

ON

DIP-1

Dat

RAD-AO4-IFS

OFF
1
2
3
4

Pwr

Err

5.3

IO-MAP

COM1 NO1 NC1


COM2 NO2 NC2

DO1

5.2

IO-MAP

2 3

DO4

COM3 NO3 NC3


COM4 NO4 NC4

IO-MAP

0 1

1 2

DO3

5.3

IO-MAP

ON

DIP-1

Dat

DO2

5.2

RAD-DOR4-IFS

S-PORT

Mesh network

OFF
1
2
3
4

Pwr

DO1

COM3 NO3 NC3


COM4 NO4 NC4

5.1

COM1 NO1 NC1


COM2 NO2 NC2

Err

DO4

4.3

IO-MAP

2 2

DO3

4.2

IO-MAP

0 0

1 1

DO1
DO2

4.1

RAD-DOR4-IFS

ON

DIP-1

Dat

RAD-DOR4-IFS

OFF
1
2
3
4

Pwr

Err

D(A) D(B)
RX TX GND
CO1 NO1 NC1

RAD-DOR4-IFS

RAD-2400-IFS

RAD-ID

1 2

RX TX

IO-MAP

9 0

0 1

Reset

Err

IO-MAP

Dat

IO-MAP

ANT

Pwr

IO-MAP

COM1 NO1 NC1


COM2 NO2 NC2

RSSI+ RSSI

I1
I2
OFF
1
2
3
4

Dat

2.3

RX TX

+24V 0V

U1
U2

Pwr

Reset

Reset

Err

2.1

3.1

DI1

RX TX

S-PORT

Dat

RAD-AI4-IFS

Pwr

RAD-ID

S-PORT

ANT

2.1

DI1L DI1H DI1


DI2L DI2H DI2

RSSI+ RSSI

RAD-DI4-IFS

2.2

+24V 0V

RAD-2400-IFS

4.3

4.1

RAD-ID

5.3

5.2

IO-MAP

5.1

IO-MAP

4.3

Reset

4.2

S-PORT

4.2

2.1
4.1

RAD-AO4-IFS

-I3
-I4

RAD-2400-IFS

+I3
+I4

RAD-DAIO6-IFS

Pwr3
Pwr4

RAD-ID

DI3L DI3H DI3


DI4L DI4H DI4

IO-MAP

D(A) D(B)
RX TX GND
CO1 NO1 NC1

IO-MAP

RX TX

S-PORT

4.1

RAD-2400-IFS

5.3

RAD-ID

5.2

RAD-AI4-IFS

5.1

RAD-DI4-IFS

4.3

IO-MAP

4.2

IO-MAP

4.1

5.2

5.3

U3
U4

I3
I4

4.1

4.2

3
4

4.3

U3
U4

I3
I4

4.1

4.2

3
4

4.3

U3
U4

I3
I4

4.1

4.2

3
4

4.3

U3
U4

I3
I4

4.1

4.2

Pwr3
Pwr4

4.3

4.1

+I3
+I4

-I3
-I4

4.2

4.3

DI3L DI3H DI3


DI4L DI4H DI4

5.1

5.2

Universal use

The Radioline wireless system


features:
Quick and easy startup
without programming
Can be extended with up to
32 I/O modules per station via
T-BUS (hot-swappable)
Applications: I/O to I/O,
I/O to serial, serial to serial
Integrated RS-232 and RS-485
interface
Trusted Wireless 2.0 technology
Adjustable data rates for the
wireless interface (16 500 kbps)
128-bit data encryption (AES)

5.3

I/O integration in the control level

Flexible network construction


You can implement various network structures with up to 250 devices quickly and easily with
Radioline. I/O modules can be connected to the controller via the integrated RS-232 and
RS-485 interface by means of wireless communication using the Modbus protocol.

PHoeNIX CoNTACT

Wireless I/O
Radioline extension modules
Various extension modules are available
for expanding the Radioline wireless
system quickly and easily. They enable the
transmission of digital and analog signals as
well as temperature signals.

Temperature
extension module
RAD-PT100-4-IFS
Order No. 2904035
Four Pt 100 inputs
Temperature measuring range:
-50C +250C
2/3-wire connection

International
Ex approval
All extension modules are
certified according to 94/9/
EC (ATEX) directives and
can therefore be used
internationally in potentially
explosive areas.

Easy installation
Create a modular wireless
station in the control cabinet
and extend or replace it easily
during operation.

10

PHoeNIX CoNTACT

Analog/digital
extension module

Analog
extension modules

Digital
extension modules

RAD-DAIO6-IFS
Order No. 2901533

RAD-AI4-IFS
Order No. 2901537

RAD-DI4-IFS, Order No. 2901535


RAD-DOR4-IFS, Order No. 2901536

One analog input:


alternatively 0/4 20 mA

RAD-AO4-IFS
Order No. 2901538

Four digital wide range inputs:


0 250 V AC/DC

One analog output:


alternatively 0/4 20 mA, 0 10 V DC

Four analog inputs:


alternatively 0/4 20 mA

Four digital relay outputs:


24 V DC / 250 V AC / 6 A

Two digital wide range inputs/outputs:


0 250 V AC/DC

Four analog outputs:


alternatively 0/4 20 mA, 0 10 V DC

Channel-to-channel electrical isolation

Channel-to-channel electrical isolation

Channel-to-channel electrical isolation

RAD-DI8-IFS, Order No. 2901539


RAD-DO8-IFS, Order No. 2902811
Eight digital inputs: 0 30.5 V DC
Two pulse inputs: 100 Hz, 32 bit
Eight digital transistor outputs:
30.5 V DC / 200 mA

Properties:
Extended temperature range:
-40C +70C
Easy module replacement
even during operation
(hot-swappable)

Easy addressing
Set the address on the
wireless module by simply
turning the thumbwheel without the need for tools.

Easy distribution
On the I/O module, the
thumbwheel is also used to
assign the inputs and outputs,
thereby easily distributing the
I/O signals in the system.

PHoeNIX CoNTACT

11

Wireless I/O
Fieldline Modular for wireless
fieldbus extension
The Bluetooth I/O system integrates
I/O signals into a fieldbus or an Ethernet
network via Bluetooth. Up to three
Wireless I/O modules can be connected
wirelessly to the base station.
Device configuration is easy: the base
station writes the connection data to
an ID plug that is then attached to the
wireless modules. The base station can be
integrated into all common fieldbus systems
using various bus couplers.
Possible areas of application
The Fieldline Modular Wireless I/O system
is particularly suitable for use in moving,
temporarily installed or difficult to access
machine units in all industrial applications
where time-critical process signals are to be
transmitted:
Fast data transmission in typically 10 ms
per module
Short range* of 20 to 50 m in
industrial halls as well as over 100 m
outdoors
* The range may be significantly above or below
that stated and depends on the environment, antenna
technology, and the product used.

12

PHoeNIX CoNTACT

Fieldline Modular
Wireless I/O base station

Fieldline Modular
Wireless I/O module

Inline Block
Wireless I/O module

FLM BT BS 3
Order No. 2736770

FLM BT DIO 8/8 M12


Order No. 2736767

ILB BT ADIO 2/2/16/16


Order No. 2884282

Base station for up to three Fieldline


Modular Wireless I/O modules

Eight digital inputs and outputs


Degree of protection: IP65

16 digital inputs and outputs,


two analog inputs and outputs

Degree of protection: IP65

Antenna connection: SMA (female)

Degree of protection: IP20

Antenna connection: SMA (female)

Antenna connection: SMA (female)


FLM BT DI 16 M12
Order No. 2693208
16 digital inputs
Degree of protection: IP65
Antenna connection: SMA (female)

Wireless I/O
base station
PLC

Bus coupler

Wireless
I/O module

Wireless
I/O module

Properties of Fieldline
Modular:
Communication is established
automatically
Communication interruptions are
detected and indicated
Extremely robust and reliable
Quick and easy startup
Can be operated alongside
WLAN without any interference,
thanks to Black Channel Listing,
Low Emission Mode (LEM), and
Adaptive Frequency Hopping
(AFH)
Parallel operation of numerous
Bluetooth systems
Protected against manipulation
and tapping

Installation close to the machine


The Wireless I/O modules can be mounted directly in the machine or system. The
last meter to the sensors and actuators is conventionally wired in a star formation, e.g.,
using pre-assembled M12 connectors.

PHoeNIX CoNTACT

13

Wireless I/O
Wireless MUX
the wireless signal cable
The Wireless MUX transmits 16 digital
and two analog signals bidirectionally, i.e.,
in both directions, which means that it
can replace a 40-wire signal cable. The
connection is continuously monitored. If
there is gross interference in the link or it
is interrupted, the outputs are reset to the
defined LOW state. This is indicated on the
module by a diagnostic LED.
The link quality display provides the user
with constant information on the quality of
the link.

Possible areas of application


The Wireless MUX is used wherever a small
number of digital or analog input and output
signals need to be exchanged wirelessly with a
remote or movable station.

14

PHoeNIX CoNTACT

Omnidirectional wireless set

Panel wireless set

Marine omnidirectional
wireless set

ILB BT ADIO MUX-OMNI


Order No. 2884208

ILB BT ADIO MUX-PANEL


Order No. 2884509

ILB BT ADIO MUX-OMNI 8/M


Order No. 2693185

Standard package consisting of two


permanently paired modules, two
omnidirectional antennas with 1.5 m cable,
and a DIN rail adapter

Package consisting of two permanently


paired modules, two panel directional
wireless antennas each with 1 m cable,
and a DIN rail adapter

Wireless MUX set with marine approvals,


consisting of two permanently paired
modules, two omnidirectional antennas
with 1.5 m cable, and a DIN rail adapter

Ranges* between 50 and 100 m in halls


and over 200 m outdoors

Distances* of over 400 m outdoors with a


free line of sight

Antenna connection: MCX (female)

Antenna connection: MCX (female)

Antenna connection: MCX (female)

Ranges* between 50 and 100 m in halls


and over 200 m outdoors

Technical data: supply voltage: 19.2 V DC 30 V DC, 16 digital/two analog inputs, 16 digital outputs up to 500 mA, two analog outputs
0 mA 20 mA or 0 V 10 V

Wireless MUX, the wireless signal cable


Connection to the controller is quick and easy using existing
input and output channels.

* The range may be significantly above or below that stated and depends on the
environment, antenna technology, and the product used.

2 analog actuators
2 analog sensors

16 digital actuators
16 digital sensors

PLC

Properties of the
Wireless MUX system:
Connections established and
signals transmitted automatically
based on fixed pairing
No configuration or settings
required
Typical transmission time of less
than 10 ms
Extremely robust and reliable
Interference-free operation
alongside WLAN
Parallel operation of numerous
Bluetooth systems
Protected against manipulation
and tapping

PHoeNIX CoNTACT

15

Wireless I/O
Expanding HART systems and
establishing new applications
By using a WirelessHART adapter and the
gateway, it is possible to adapt existing systems
to new regulations, optimize maintenance
schedules or acquire standard data.
The gateway can communicate with the
control system via Modbus/TCP, HART-IP,
and FDT/DTM. Thanks to the use of HART-IP
or FDT/DTM framework structures, remote
devices can be fully configured via the wireless
network.
Possible areas of application
Conventional analog field devices in the process
industry which are connected to non-HARTcompatible control systems can be expanded
easily in terms of their function without needing
to replace the existing controller hardware by
using WirelessHART networks. A wide range
of parameterization and diagnostic functions
are integrated into the existing system without
having to stop the process.

16

PHoeNIX CoNTACT

WirelessHART
gateway
RAD-WHG/WLAN-XD
Order No. 2900178

RAD-WHA-1/2NPT
Order No. 2900100

Enables HART data from field devices to


be accessed via Modbus/TCP or HART-IP

Up to four HART devices or one


420mA non-HART device can be
connected to one adapter

Supports up to 250 WirelessHART field


devices
Easy programming and diagnostics by
means of integrated web server

Retrofit installation

Control system

New installations

RAD-WHG/W
RAD-WHG/WLAN-XD
WLA
AN-XD

4 20 mA

4 20 mA

WLAN

ST
MESH
LINK
DATA

RF Link
RF Data

RESE
ESET
T
RESET

ERR

RSSI
+24V GND
Po
Power

WirelessHART
adapter

RF Link

Loop-powered or 24 V DC power supply


Removable antenna for connecting a
coaxial cable and a high-gain antenna

Your advantages:
Use of the same maintenance
and diagnostic tools as wired
HART devices
Integrated WLAN client enables
the gateways to be installed
directly in the field, thereby
establishing a reliable network
Lower material and installation
costs compared to wired
solutions
Labor costs saved

WirelessHART the solution for retrofit and new installations

PHoeNIX CoNTACT

17

Wireless I/O
TC Mobile for monitoring sensors via
the mobile phone network
Monitor analog and digital values easily and
securely via the mobile phone network
and switch relays remotely. TC Mobile I/O
transmits data securely via SMS, e-mail, and
GPRS. Thanks to the large voltage range
and the various inputs, the signaling system
can be used in a wide range of applications.

Possible areas of application


Machine, building, and system monitoring
Pumps, wastewater treatment plants, and
water supply
Lighting control systems and remote
switchgear
Street lighting
Elevators and gates
Alarm technology and building services
HVAC technology
Battery monitoring up to 60 V
Railway applications according to EN 50121-4

18

PHoeNIX CoNTACT

Mobile radio module, DC

Mobile radio module, AC

TC MOBILE I/O X200


Order No. 2903805
Remote signaling system, SMS/e-mail (client)

TC MOBILE I/O X200 AC


Order No. 2903806
Remote signaling system, SMS/e-mail (client)

TC MOBILE I/O X300


Order No. 2903807
Remote control system, GPRS (ODP client)

TC MOBILE I/O X300 AC


Order No. 2903808
Remote control system, GPRS (ODP client)

Four digital inputs

Four digital inputs

Two relay outputs

Two relay outputs

Two analog inputs for voltage or current

Voltage range: 93 V AC 250 V DC

Voltage range: 10 V DC 60 V DC

E-mail
SMS

Mobile radio
module

Unbeatably versatile use:


Suitable for buildings and harsh
industrial environments
Monitoring of connected sensors
(0 20 mA)
Monitoring of voltages up to 60 V
Relay switching via the mobile
phone network
SMS, e-mail, and OPD
communication
Large supply voltage range
(AC or DC)

Monitoring sensors via the mobile phone network


The TC Mobile I/O product range allows you to monitor analog current levels (20 mA) and
analog voltage values (up to 60 V) and switch relays remotely. Communication takes place via
SMS, e-mail or with an ODP server.

PHoeNIX CoNTACT

19

Wireless Serial
Radioline for wireless networking of
serial interfaces
The wireless module can be used to
wirelessly network multiple controllers
or serial I/O devices quickly and easily via
RS-232 and RS-485 serial interfaces. Data
transmission is transparent, which means
that any protocols, such as Modbus, can
be forwarded. In addition, various network
structures can be implemented: from
a simple point-to-point connection to
complex mesh networks.
Convenient software diagnostics
All network devices can be monitored
conveniently via the master:
Online diagnostics:
- Network structure
- Signal quality of each network station (RSSI)
- Recording of RSSI signal and
I/O status of each network station
Exclusion of up to two frequency bands
(WLAN channels)
Extended network settings

International Ex approval
The modules are certified according
to 94/9/EC (ATEX) directives and can
therefore be used internationally in
potentially explosive areas.

20

PHoeNIX CoNTACT

Wireless module

I/O extension modules

RAD-868-IFS
Order No. 2904909

RAD-DI4-IFS
Order No. 2901535

Digital IN

RAD-DAIO6-IFS
Order No. 2901533

Analog/Digital IN/OUT

RAD-900-IFS
Order No. 2901540

RAD-DOR4-IFS
Order No. 2901536

Digital OUT

RAD-AI4-IFS
Order No. 2901537

Analog IN

RAD-2400-IFS
Order No. 2901541

RAD-DI8-IFS
Order No. 2901539

Digital IN

RAD-AO4-IFS
Order No. 2901538

Analog OUT

Can be extended with I/O modules via


T-BUS

RAD-DO8-IFS
Order No. 2902811

Digital OUT

RAD-PT100-4-IFS
Order No. 2904035

Temperature module

Extended temperature range:


-40C +70C

For configuration sticks and configuration cables see page 43.

Integrated RS-232 and RS-485 interface

2.1

2.2

2.3

+24V 0V

RSSI+ RSSI

S-PORT

RAD-2400-IFS

ANT

Dat

9 1

0 2
1 3

Reset

Err

RAD-ID

Pwr

RX TX

D(A) D(B)
RX TX GND
CO1 NO1 NC1

2.2

2.3

0 1
1 2

Pwr
Dat
Err

9 4

0 5
1 6

Pwr
Dat
Err

9 3

0 4
1 5

Reset

9 0

Reset

Err

2.3

ANT

Reset

S-PORT
Dat

RAD-ID

Pwr

2.2

RSSI+ RSSI

S-PORT

RAD-2400-IFS

ANT

2.1

+24V 0V

RSSI+ RSSI

S-PORT

2.1

+24V 0V

RAD-2400-IFS

2.3

RSSI+ RSSI

RAD-2400-IFS

2.2

+24V 0V

ANT

4.3

RAD-ID

2.1

4.2

RAD-ID

4.1

RX TX

RX TX

RX TX

D(A) D(B)
RX TX GND
CO1 NO1 NC1

D(A) D(B)
RX TX GND
CO1 NO1 NC1

D(A) D(B)
RX TX GND
CO1 NO1 NC1

4.1

4.2

4.3

4.1

4.2

4.3

4.1

4.2

4.3

The Radioline wireless system


features:
Quick and easy startup
without programming
Easy point-to-point or
network connections (star, mesh)
Can be extended with up to 32
I/O modules per station via
T-BUS (hot-swappable)
Applications: I/O to I/O,
I/O to serial, serial to serial
Trusted Wireless 2.0 technology
Adjustable data rates for the
wireless interface (16 500 kbps)
128-bit data encryption (AES)

Replacement for serial cabling


Connect your controller to serial field devices using wireless technology. The slaves are
connected directly or via repeater slave intermediate stations. Up to 250 repeater slaves
can be connected one after the other to extend the wireless path. Serial I/O devices and I/O
extension modules can be connected to the intermediate stations.

PHoeNIX CoNTACT

21

Wireless Serial
Interface converters for
RS-232,RS-422, and RS-485
The Bluetooth converter can be used to
convert RS-232, RS-422, RS-485 2-wire
serial interfaces, and USB to the licensefree Bluetooth wireless standard. It serves
as a flexible and easy replacement for
cabling in order, for example, to perform
programming and diagnostics tasks via a
notebook or as an inexpensive alternative
to slip rings, drag chains, and fieldbus
cables, such as Modbus and PROFIBUS.

Possible areas of application


Wireless programming access between
a notebook and a controller
Data link between a third-party device
with integrated Bluetooth interface and
a controller
Networking of mobile devices
Integration of a bus device into an
existing bus system, e. g ., Modbus or
PROFIBUS

Integrated USB interface


for device configuration
without power supply.
The current signal quality can be read via
digital outputs DO1/DO2.

22

PHoeNIX CoNTACT

Bluetooth converter

Bluetooth PROFIBUS set

PSI-WL-RS232-RS485/BT/2DO
Order No. 2313805

PSI-WL-PROFIB/BT-SET/2DO
Order No. 2313876

Universal Bluetooth converter for RS-232,


RS-422, RS-485 2-wire

Preconfigured for an invisible,


password-protected point-to-point
PROFIBUS connection

PSI-WL-RS232-RS485/BT/HL
Order No. 2313795

Transmission speed:
187.5 kbps

Bluetooth converter with hazardous


location approval

Consisting of two permanently


paired Bluetooth converters and two
omnidirectional antennas

Point-to-point and multipoint


connections (up to seven slaves)

Antenna connection: MCX (female)

Antenna connection: MCX (female)

Flexible parameterization
options and possible
applications:
Suitable for worldwide use,
thanks to adjustable transmission
power (-28 20 dBm)
Can be used for RS-232/422/485
2-wire interfaces up to
187.5 kbps
Transceiver for distances of up
to 150 m

PSI-WL-RS232RS485/BT/2DO
Ord.-No. 23 13 805

Vcc
TD

ANT

RD
USB
D01
D02
SER ERR

PSI-WL-RS232RS485/BT/2DO
Ord.-No.. 23 13 805

Vcc
TD

ANT

RD
USB
D01
D02
SER ERR

PSI-WL-RS232RS485/BT/2DO
Ord.-No.. 23 13 805

Vcc
TD

PSI-WL-RS232RS485/BT/2DO
Ord.-No.. 23 13 805

Vcc

ANT

TD

RD

ANT

RD
USB

USB

D01

D01

D02
SER ERR

D02
PSI-WL-RS232RS485/BT/2DO
Ord.-No.. 23 13 805

Vcc
TD

SER ERR

ANT

RD
USB
D01
D02
SER ERR

High transmission reliability:


Secure and tamper-proof data
transmission, thanks to password
protection, 128-bitencryption,
and invisible,fixed device pairing
Coexistence with other wireless
systems due to the adaptive
frequency hopping (AFH) method

Transmit and request serial data securely


Use the Bluetooth converter as an access point and call control data via your noteboook.

PHoeNIX CoNTACT

23

Wireless Serial
COM server integration of serial
devices into the Ethernet network
The COM server for WLAN closes the gap
between serial interfaces on automation
devices and mobile industrial applications
with an Ethernet interface.
By using the device server, non-networkcapable components can also be accessed
via local networks or the Internet. This
enables you, for example, to request
system states, perform software updates,
carry out remote maintenance or
transmit visualization data.
Redirector software
The redirector software, which is supplied as
standard with the COM server, redirects the
serial data of the application software to the
LAN interface of the PC using a virtual COM
port. This allows data to be transmitted in an
existing Ethernet network without any range
restrictions or additional cable costs. At the
automation devices in the field, a COM server
converts the Ethernet data back into serial
data. It is therefore possible to access remote
serial devices via the network just as easily as
if these devices were connected directly to
the PC.

24

PHoeNIX CoNTACT

LAN network

Serial device server


for 802.11 WLAN

Serial
device

FL COMSERVER WLAN 232/422/485


Order No. 2313559

FL COMSERVER
WLAN 232/422/485
Ord.-No. 23 13 559

Vccc
TTD
D

ANT

RD
R
D
USB

Access
point

D01
D02
SER ERR

WLAN
COM server

Converts RS-232, RS-422, RS-485 serial


interfaces to Wireless LAN
Protocols: TCP, UDP

WLAN infrastructure
network

54 Mbps WLAN according to IEEE 802.11 b/g

WLAN ad hoc
network

Transmission speed can be adjusted via


configuration software
LEDs for status and diagnostics indicators
LED bar graph for WLAN link quality

FL WLAN EPA

PWR

Bluetooth Ethernet Port Adapter


Ord. No.: 2692791

)))
LAN

FL WLAN 802.11 b/g

FL COMSERVER
WLAN 232/422/485
Ord.-No. 23 13 559

WLAN Ethernet
adapter

Vccc
TTD
D

ANT

RD
R
D

FL COMSERVER
WLAN 232/422/485
Ord.-No. 23 13 559

Vccc
TTD
D

TTD
D

USB

D01

D01

D02

Serial
device

Infrastructure mode
Integration of devices in an Ethernet network
via WLAN access point.

D02

Link quality can be checked via digital


outputs

D02

SER ERR

SER ERR

Serial
device

Serial
device

Ad hoc mode
Direct connection between up to seven
devices for constructing small networks.

FL COMSERVER
WLAN 232/422/485
Ord.-No. 23 13 559

Vcc
cc
TD

ANT

RD
R
D
USB

D01

SER ERR

Ethernet
device

FL COMSERVER
WLAN 232/422/485
Ord.-No. 23 13 559

Vccc

ANT

RD
R
D
USB

FL COMSERVER
WLAN 232/422/485
Ord.-No. 23 13 559

Vcc
cc

ANT

TD

RD

ANT

RD

USB

USB

D01

D01

D02

D02

SER ERR

SER ERR

FL COMSERVER
WLAN 232/422/485
Ord.-No. 23 13 559

Vcc
cc
TD

ANT

RD
USB
D01
D02

WLAN

WLAN

SER ERR

FL COMSERVER
WLAN 232/422/485
Ord.-No. 23 13 559

Vcc
cc
TD

ANT

FL COMSERVER
WLAN 232/422/485
Ord.-No. 23 13 559

Vcc
cc
TD

RD
USB

USB
D01

D02

Serial tunneling
COM servers replace serial cables by using
existing Ethernet networks.

ANT

RD

D01

SER ERR

D02
SER ERR

Virtual COM ports


Virtual COM ports redirect serial PC
applications to Ethernet. The COM servers
create new COM ports in the field.

PHoeNIX CoNTACT

25

Wireless Serial
Mobile phone modem for worldwide
communication via GSM
The GSM/GPRS modem can be used in
all GSM networks and enables worldwide
access to machines and systems. Using
wireless remote maintenance it is therefore
possible to avoid downtimes and minimize
costs.
The configurable warning or alarm inputs
are useful for remote monitoring. When
they are activated, the modem automatically
dials a freely definable phone number and
sends stored text messages as a fax, SMS or
e-mail. The integrated sleep function rounds
off the range of features offered by the
modem.

Possible areas of application


Process data acquisition
Alarm generation
Remote maintenance of systems and
machines
Remote programming

Compact GSM/GPRS modem


The serial GSM/GPRS modem can be used
to easily establish a secure point-to-point
connection. Direct communication with
the machine controller is via the RS-232
interface.

26

PHoeNIX CoNTACT

Secure dial-up connection establishment

PSI-GPRS/GSMMODEM/RS232-QB
Ord.-No.: 23 13 106

VCC
RD
ANT

Analog
phone network

ALR
10/100 BASE-T

NET
DCD
SIM

GSM
mobile phone network
(GPRS/EDGE)
PSI-DATA/BASICMODEM/RS232
Ord.-No. 23 13 067

LINE

OH
DTR

GSM/GPRS modem with


RS-232 interface
PSI-GPRS/GSM-MODEM/RS232-QB
Order No. 2313106
Can be used in all 850 MHz, 900 MHz,
1800 MHz, and 1900 MHz GSM networks
Integrated TCP/IP stack
Password protection, selective call
acceptance, callback function
PIN stored in modem is encrypted
Supply voltage:
10.8 V DC 30 V DC

DCD
AA

Mobile machines or remote systems often


do not offer the option of connecting to
a fixed-line network. GSM networks are a
universal alternative here. The connection
is established by directly dialing a phone
number and can be made secure by
means of password protection, as an
option. Thanks to easy handling and the
constant signal runtime, the CSD dialup connection is a popular method used
for the global remote maintenance of
machines and systems.

The GPRS functionality is ideal for


process data acquisition where permanent
communication is required. GPRS
connections are not billed according to
the connection time, but based on the
volume of data.

Automatic alarm generation


SMS
E-mail
Fax
PSI-GPRS/GSMMODEM/RS232-QB
Ord.-No.: 23 13 106

VCC
RD
ANT

Phone
network

ALR
NET
DCD
SIM

VCC

Switching output

RD
ANT
ALR
NET
DCD
SIM

GPRS functionality always online


PSI-GPRS/GSMMODEM/RS232-QB
Ord.-No.: 23 13 106

VCC
RD
ANT

The industrial modems


offer the following features:
Easy startup by means of plug
and play
User-friendly configuration
software
Tried-and-tested interaction with
controllers and industrial PCs
from many manufacturers

PSI-GPRS/GSMMODEM/RS232-QB
Ord.-No.: 23 13 106

ALR
NET
10/100 BASE-T

DCD
SIM

PSI-GPRS/GSMMODEM/RS232-QB
Ord.-No.: 23 13 106

VCC
RD

GPRS

ANT

Internet

ALR
NET
DCD
SIM

Remote control connection


PSI-GPRS/GSMMODEM/RS232-QB
Ord.-No.: 23 13 106

VCC
RD
ANT
ALR
NET
10/100 BASE-T

DCD

PSI-GPRS/GSMMODEM/RS232-QB
Ord.-No.: 23 13 106

SIM

VCC
RD
ANT
ALR
NET
10/100 BASE-T

DCD
SIM

PSI-GPRS/GSMMODEM/RS232-QB
Ord.-No.: 23 13 106

VCC
RD
ANT
ALR
NET
DCD
SIM

PSI-GPRS/GSMMODEM/RS232-QB
Ord.-No.: 23 13 106

VCC

GPRS

RD
ANT

Internet

ALR
NET
DCD
SIM

PHoeNIX CoNTACT

27

Wireless Ethernet
Industrial Bluetooth
The industrial Bluetooth modules allow
you to wirelessly transmit control data to
mobile or difficult to access automation
devices quickly and easily. Bluetooth
communication is characterized by
particularly robust transmission under
difficult ambient conditions. This allows you
to establish functionally safe communication
via PROFIsafe or SafetyBridge technology.

Possible areas of application


Bluetooth enables mobile devices to be
integrated into industrial control networks
wirelessly, thereby eliminating the need for
expensive cable runs.
Robots and traveling robots
Handling machines, packaging machines,
pallet wrapping machines
Moving machine parts
Cranes and lifting equipment

28

PHoeNIX CoNTACT

Bluetooth Ethernet
adapter

Bluetooth Ethernet
adapter set

Bluetooth access point

FL BT EPA
Order No. 2692788

FL BT EPA AIR SET


Order No. 2693091

FL BT EPA MP
Order No. 2701416

Internal antenna

Solution set consisting of:


2 x FL BT EPA, cable, and plug

External, replaceable antenna (supplied)

Maximum of one wireless connection

Connection: RSMA (male)


Maximum of seven wireless connections

Technical features: Bluetooth V2.1+EDR, frequency band 2.4 GHz, WLAN Black Channel List, Low Emission Mode (LEM), IP65 protection,
M12 connections for voltage and LAN, power supply 9 30 V DC, autocrossing, PROFINET prioritizing, LLDP, 128-bit data encryption,
ambient temperature -40C +65C, web interface, SNMP, AT commands, UL/cUL Class 1 Div 2 Hazardous location
Accessories: assembly adapter (Order No. 2701134), DIN rail adapter (Order No. 2701133)

S-MAX

PLC

Safety
DI

SYS

ILC 170 ETH 2TX


Order-No.: 2916532

AUTOMATIONWORX
MRESET
STOP
RUN/PROG

RESET

PRG

FL BT EPA

Bluetooth Ethernet Port Adapter


Ord. No.: 2692788

LINK

ACT

LINK

ACT

1.1

2.1

1.1

2.1

1.1

2.1

1.1

2.1

1.1

2.1

1.1

2.1

1.1

2.1

1.1

2.1

1.2

2.2

1.2

2.2

1.2

2.2

1.2

2.2

1.2

2.2

1.2

2.2

1.2

2.2

1.2

2.2

1.3

2.3

1.3

2.3

1.3

2.3

1.3

2.3

1.3

2.3

1.3

2.3

1.3

2.3

1.3

2.3

1.4

2.4

1.4

2.4

1.4

2.4

1.4

2.4

1.4

2.4

1.4

2.4

1.4

2.4

1.4

2.4

PWR

)))
LAN

FL BT EPA

Bluetooth Ethernet Port Adapter


Ord. No.: 2692788

PWR

)))
LAN

FL BT EPA

Bluetooth Ethernet Port Adapter


Ord. No.: 2692788

Safety
DO

PWR

)))
LAN

ILC 150 ETH


Order-No.: 2985330
HW/FW: 00/100
MAC Addr.: 00.A0.48.04.09.C0

AUTOMATIONWORX
MRESET
STOP
RUN/PROG

RESET

PRG

FL BT EPA

Ethernet via
Bluetooth network
FL BT EPA

Bluetooth Ethernet Port Adapter


Ord. No.: 2692788

PWR

)))
LAN

PWR

Bluetooth Ethernet Port Adapter


Ord. No.: 2692788

)))
LAN

FL BT EPA

Bluetooth Ethernet Port Adapter


Ord. No.: 2692788

PWR

1.1

2.1

1.1

2.1

1.1

2.1

1.1

2.1

1.1

2.1

1.1

2.1

1.1

2.1

1.1

2.1

1.2

2.2

1.2

2.2

1.2

2.2

1.2

2.2

1.2

2.2

1.2

2.2

1.2

2.2

1.2

2.2

)))
LAN

1.3

2.3

1.3

2.3

1.3

2.3

1.3

2.3

1.3

2.3

1.3

2.3

1.3

2.3

1.3

2.3

1.4

2.4

1.4

2.4

1.4

2.4

1.4

2.4

1.4

2.4

1.4

2.4

1.4

2.4

1.4

2.4

LINK

Ethernet/PROFINET

Bluetooth applications
The Bluetooth BT EPA modules replace
individual Ethernet or PROFINET cables
leading to automation devices with a
reliable wireless connection.
The BT EPA MP enables up to seven
Bluetooth modules to be connected to the
Ethernet network at the same time.

Safety via
Bluetooth network

PHoeNIX CoNTACT

29

Wireless Ethernet
Industrial WLAN
The latest generation of WLAN modules
is characterized by robust industrial
technology combined with high performance
and modern MIMO technology. The central
cluster management at the WLAN 5100
access point makes the configuration and
maintenance of larger WLAN networks
considerably easier. Using the Ethernet
adapters, you can integrate automation
components such as controllers or I/O
modules into the WLAN network quickly
and easily.

Possible areas of application


Wireless LAN is particularly suitable for
implementing a system-wide wireless
infrastructure:
Mobile maintenance
Electric monorail systems
Automated guided vehicle systems and
forklift trucks
Storage and retrieval machines and
warehouse shuttles
Video monitoring

30

PHoeNIX CoNTACT

WLAN 5100
access point

WLAN Ethernet
adapter

Control box sets

FL WLAN 5100
Order No. 2700718
not for the USA or Japan

FL WLAN EPA
Order No. 2692791
Integrated antenna IEEE 802.11b/g/n, 2.4 GHz

FL RUGGED BOX OMNI-1


Order No.. 2701430
with omnidirectional antennas

FL WLAN 5101
Order No. 2701093
for the USA and Canada

FL WLAN EPA 5N
Order No. 2700488
Integrated antenna IEEE 802.11a/n, 5 GHz

FL WLAN 5102
Order No. 2701850
for Japan

FL WLAN EPA RSMA


Order No. 2701169
IEEE 802.11a/b/g/n, 2.4 GHz and 5GHz,
external antenna, RSMA

FL RUGGED BOX OMNI-2


Order No. 2701439
with omnidirectional antennas and power
supply unit

SD-FLASH 2 GB
Order No. 2988162
IEEE 802.11 a/b/g/n, WLAN access point,
client, repeater, frequency band 2.4 GHz
and 5 GHz, MIMO technology 3 x 3:2, up
to 300 Mbps, cluster management

WLAN client, IEEE 802.11n, MIMO


technology 1 x 1:1, IP65 protection,
M12 connections for voltage and LAN,
power supply 9 30VDC, operating
modes: single-client and multi-client

FL RUGGED BOX DIR-1


Order No. 2701440
with panel antenna
FL RUGGED BOX
Order No. 2701204
without antenna accessories
Set for constructing wireless systems for
industrial applications, IP65, with DIN rail,
plugs, and screw connections,
100 240 V power supply unit, without
devices

Industrial Ethernet / PROFINET


WLAN 5100
access point
Configuration

WLAN network
Production 1
Seamless
roaming

Industrial Ethernet
WLAN EPA
client

Cluster management makes things easier


Cluster management, a feature of WLAN 5100, enables the quick
configuration and startup of all access points via a single web
interface.

WLAN 5100
client/repeater

Typical WLAN network structure


The WLAN EPA enables interruption-free roaming in duo mode.

PHoeNIX CoNTACT

31

Wireless Ethernet
Mobile phone routers for worldwide
network access
Mobile phone routers support highperformance remote connections to
industrial Ethernet networks, which
can be used to transmit sensitive data
securely over mobile phone networks. The
integrated firewall and VPN (Virtual Private
Network) support protect the application
against unauthorized access.
The Ethernet connection can be used for
system-wide remote maintenance of all
connected components in the network,
such as drives, controllers, control panels,
and visualization PCs.

32

PHoeNIX CoNTACT

Possible areas of application


Efficient remote maintenance of machines
and systems
Continuous data acquisition from stations
throughout the world
Integration of remote stations into
IP networks via the mobile phone network
Alarm generation by SMS and e-mail

Mobile phone router


GPRS/EDGE

Mobile phone router


UMTS/HSPA

UMTS/HSPA/CDMA
mobile phone router

PSI-MODEM-GSM/ETH
Order No. 2313355

PSI-MODEM-3G-ROUTER
Order No. 2314008

TC MGUARD RS2000 3G VPN


Order No. 2903441

Worldwide data links to small applications

Worldwide high-speed data links and alarm


generation via 3G mobile phone networks

TC MGUARD RS4000 3G VPN


Order No. 2903440

UMTS/HSPA tri band (850 MHz/900 MHz/


2100 MHz) with GPRS/EDGE fallback

Integrated four-port switch

GSM quad band (850 MHz/900 MHz/


1800 MHz/1900 MHz)
Alarm generation by SMS and e-mail
Support for IPsec and OpenVPN

Two SIM card slots for maximum network


availability

American CDMA mobile phone networks


are now supported in addition to UMTS/
HSPA

Support for IPsec and OpenVPN

Two SIM card slots


Up to ten IPsec VPN tunnels
SD memory cards as replaceable
configuration memory

Mobile
phone
router
Machine
Service control
center
P1

Stat Mod Info2

P2

Err

LAN 4
LAN 3

Mobile
phone
router

Configuration

ANT

LAN 2

LAN 1

Fault Info1

SIM 1
SIM
M2

GPS

VPN

Machine
Security
router
P1

Stat Mod Info2

P2

Err

LAN 4
LAN 3
ANT

Mobile
phone
router

SIM 1
SIM
M2

GPS

Configuration

LAN 2

LAN 1

DMZ

WAN 1

Fault Info1

Machine and
customer network

Data links
Worldwide Internet data link via mobile phone networks at up to 14.4 Mbps
Flexible use in small machines to larger system networks
Secure VPN communication

Industrial mobile phone data


transmission
Modern mobile phone technology
offers efficient, high-performance
communication for many industrial
applications. The mobile phone
quick start guide answers the
most frequently asked customer
questions in terms that are as
brief and easily comprehensible as
possible and provides practical tips.

PHoeNIX CoNTACT

33

Accessories
Systems for autonomous power supply
With the solar and battery systems, it
is possible to acquire data from remote
sensors independently of the power supply
network. A charge controller, solar battery,
surge protection, and fuses are supplied
prewired in a robust control cabinet. The
systems are designed in such a way that
sufficient solar power is provided even on
short, dark winter days.
The solar modules generate
sufficient power to supply
wireless modules, GSM
modems, distributed measuring
sensors or other devices and
to recharge the solar batteries.
The required power depends
on the connected load and
the sunlight in the installation
location.

Criteria for yield calculations


Location:
Unobstructed sunlight throughout the year
Alignment:
Solar modules facing south
(locations in the Northern Hemisphere)
Tilt angle of the solar modules:
Optimum tilt angle in winter: 60
Shading:
Consideration of shading caused by
buildings or trees in future
Season:
The solar systems have been configured
for the month with the poorest weather
(winter). During this time, the solar panels
only provide around 1/4 of the daily yield
that they provide in the summer months

Your advantages:
Ideal for all distributed applications with low
energy consumption
Easy startup: the control cabinet is prewired
Worldwide use, thanks to the universal
module mounting bracket with a tilt angle
that can be adjusted in increments

34

PHoeNIX CoNTACT

The map shows the intensity of


solar radiation around the world

Low

24 V/200 Wp solar set

High

24 V/100 Wp solar set

RAD-SOL-SET-24-200
Order No. 2917722

RAD-SOL-SET-24-100
Order No. 2885472

Nominal voltage: 24 V

Nominal voltage: 24 V

Max. power: 200 Wp

Max. power: 100 Wp

Battery capacity: 100 Ah

Battery capacity: 40 Ah

Ambient temperature range: -20C +50C

Ambient temperature range: -20C +55C

Max. load approx. 3 8.5 W *

Max. load approx. 1 3.8 W *

Scope of supply: solar modules, prewired control cabinet with charge controller, two solar batteries, surge protection, and mounting
material incl. mast mount
* Maximum connected load for year-round constant load according to power reserve and installation location.

PHoeNIX CoNTACT

35

Accessories
Antennas
The single most important item affecting
radio performance is the antenna system.
Careful attention must be given to this part
of an installation or the performance of the
entire system will be compromised.
The antennas are specially designed for
industrial use at the intended frequency
of operation. Select an antenna with an
appropriate gain for the intended field of
application.

36

PHoeNIX CoNTACT

Possible areas of application


Omnidirectional antennas
For short to medium distances
Numerous devices in different directions
Versatile applications
Panel antennas
Bridging large distances
Point-to-point connections
Stationary or linear applications
Decoupling due to directivity in the case of
multiple point-to-point paths

Indoor applications
Access points for
extensive hall lighting

Vehicles
moving in a line

Freely moving vehicles,


e.g., automated guided vehicle
system

Slip ring replacement on


rotating machine parts

Outdoor applications
Permanently installed
stations across larger
distances

Devices moving in a line


across medium and large
distances

Rotating parts across medium distances

Omnidirectional antenna
Omnidirectional antennas are used when the wireless modules
are facing different directions or are mobile. As a result of
their lower gain, they are more suitable for short to medium
distances.
In reflective indoor environments where there is no line of
sight, the signal may be reflected from the sender to the
receiver. In such cases it is important to ensure that the
omnidirectional antenna is not mounted immediately in front
of reflective (metallic) surfaces.
The ideal installation location is the top of a mast or on
a control cabinet so that the antenna has the greatest
possible free space in all directions. In the case of multiple
omnidirectional antennas, these should be installed with
sufficient spacing.

Meshed networks

Panel antenna
The use of panel antennas is recommended at permanently
installed, remote stations when large distances need to be
covered with a line of sight.
Panel antennas emit the transmission power in a preferred
direction. This increases the range and reduces the chances of
interference from other users outside the pattern.
The higher the gain of a panel antenna, the smaller its pattern
(opening angle). This means that the antennas need to be
precisely aligned with one another.

PHoeNIX CoNTACT

37

Accessories
Cables and adapters
It goes without saying that we also offer
the necessary accessories for using our
Wireless product range indoors and
outdoors.
All components are designed for industrial
use and therefore operate just as safely and
reliably as the wireless modules.

Control
cabinet/
control box
For antennas
with extension
cable

1
2
3
4
5
6

Simplified antenna connection


All devices with RSMA connection are
connected directly to the N connection of the
antennas via a cable. Various cable lengths
between 50 cm and 5 m are available.

N connection

RSMA
connection

38

PHoeNIX CoNTACT

Control box
Wireless module
Pigtail
Surge protection
Antenna cable
Antenna

Planning a radio link

Fresnel zone
d
r

The radius of
the Fresnel zone
corresponds to the
desired antenna height.
It depends on the radio
frequency and the
distance between the
antennas.

There should be a line of sight, especially


in the event of longer distances,
between the antennas of the wireless
devices.
To keep the Fresnel zone free from any
obstacles, it may be necessary to mount
the antennas a few meters high. This
area should also be free from any other
obstacles.

Obstacles outside or inside


buildings
The wireless path may also work if
obstacles are within the Fresnel zone
(house, tree, etc.). The decisive factor
is the number of obstacles and the area
they occupy in this zone. In this case it
is recommended that you perform test
measurements.

Inside buildings, in conventional


automation environments, there is a
predominance of reflections, which do
not occur outdoors. They contribute to
a good wireless connection even if the
Fresnel zone is not free from obstacles.

Wireless path distance (d)

Antenna height (r)


868/900 MHz

Antenna height (r)


2.4 GHz

Antenna height (r)


5 GHz

200 m

4m

2.5 m

1.5 m

500 m

6.5 m

4m

2.5 m

1000 m

9m

5.5 m

4m

2000 m

13 m

8m

5.5 m

4000 m

18.5 m

11 m

8m

10,000 m

29 m

20,000 m

41.5 m

30,000 m

50 m (900 MHz only)

Radius of the Fresnel zone depending on the frequency and distance. This gives the mounting height for wireless devices (antennas).

PHoeNIX CoNTACT

39

Omnidirectional antenna
2.4 GHz

RAD-ISM-2400-ANT-OMNI-2-1
Order No. 2867461 (MCX, male m, 1.5)
RAD-ISM-2400-ANT-OMNI-2-1-RSMA
Order No. 2701362 (RSMA, male, 1.5 m)
Temperature: -20C +65C
Degree of protection: IP65
Gain: 2 dBi

RAD-ISM-2400-ANT-VAN-3-0-SMA
Order No. 2885867 (SMA, male, 1.5 m)
RAD-ISM-2400-ANT-VAN-3-1-MCX
Order No. 2885702 (MCX, male, 1.5 m)
RAD-ISM-2400-ANT-VAN-3-0-RSMA
Order No. 2701358 (RSMA, male, 1.5 m)
RAD-ANT-VAN-MKT
Order No. 2885870 (bracket for wall mounting)

RAD-ISM-2400-ANT-OMNI-5-0
Order No. 2884923

Temperature: -20C +65C


Degree of protection: IP55
Gain: 5 dBi
Connection: SMA (male)

Gain: 3 dBi
Vandal-proof

Omnidirectional antenna
5 GHz

Panel antenna
2.4 and 5 GHz

2.4 GHz and 5 GHz

ANT-OMNI-5900-01
Order No. 2701347

RAD-ISM-2459-ANT-FOOD-6-0
Order No. 2692526

ANT-DIR-2459-01
Order No. 2701186

Temperature: -40C +70C


Degree of protection: IP55
Gain: 5 dBi
Connection: N (female)
Including mounting bracket

Panel antenna
2.4 GHz

RAD-ISM-2400-ANT-PAN-8-0*
Order No. 2867610 (linear polarized)
RAD-ISM-2400-ANT-CIR-8-0
Order No. 2884936 (circular polarized)

40

Temperature: -40C +80C


Degree of protection: IP55
Gain: 8 dBi
Connection: SMA (female)
Including mounting bracket

PHoeNIX CoNTACT

Temperature: -40C +80C


Degree of protection: IP67
Gain: 6 dBi @ 2.4 GHz/8 dBi @ 5.6 GHz
Connection: N (female)
Including 1 m N(m) - SMA(m) cable

Temperature: -40C +80C


Degree of protection: IP67
Gain: 9 dBi
Connection: N (female)
Including mounting bracket

Parabolic panel antenna


2.4 GHz

5 GHz

RAD-ISM-5000-ANT-PAR-18-N
Order No. 5606613

RAD-ISM-2400-ANT-PAR-19-0
Order No. 2867885

5 GHz WLAN
Gain: 18 dBi
Connection: n (female)

Temperature: -40C +70C


Degree of protection: IP65
Gain: 19 dBi
Connection: N (female)

868 MHz

RAD-ISM-2400-ANT-OMNI-6-0*
Order No. 2885919 (degree of protection: IP55)
RAD-2400-ANT-OMNI-6-0-SW
Order No. 2903219 (resistant to salt water, degree of
protection: IP65)

Temperature: -40C +80C


Gain: 6 dBi
Connection: N (female)
Including mounting bracket

5 GHz

ANT-OMNI-868-01
Order No. 2702136

Resistant to salt water


Temperature: -40C +80C
Degree of protection: IP65
Gain: 6 dBi
Connection: N (female)
Including mounting bracket

Yagi panel antenna


868 MHz and 900 MHz

900 MHz

RAD-ISM-900-ANT-OMNI-5
Order No. 2867199 (gain: 7 dBi)
RAD-ISM-900-ANT-OMNI-FG-3-N
Order No. 2867791 (gain: 5 dBi)
RAD-ISM-900-ANT-OMNI-FG-6-N
Order No. 2885579 (gain: 8 dBi)
Degree of protection: IP65
Connection: N (female)

Adapter

1)
ANT-DIR-5900-01
Order No. 2701348 (dual-slant antenna)

Temperature: -40C +80C


Degree of protection: IP67
Gain: 9 dBi
Connection: N (female)
Including mounting bracket

RAD-ISM-900-ANT-YAGI-6.5-N
Order No. 2867814 (gain: 8.5 dBi, 1.5 m cable)
RAD-ISM-900-ANT-YAGI-3-N
Order No. 2867801 (gain: 5 dBi, 0.6 m cable)
Temperature: -40C +80C
Degree of protection: IP65
Connection: N (female)

2)

3)

4)

5)

1) RAD-ADP-N/F-N/F
Order No. 2867843 (N (female) > N (female))
2) RAD-ADP-N/M-SMA/F
Order No. 2917036 (N (male) > SMA (female))
3) RAD-ADP-SMA/F-SMA/F
Order No. 2884541 (SMA (female) > SMA (female))
4) RAD-ADP-RSMA/F-SMA/F
Order No. 2884538 (RSMA (male) > SMA (female))
5) RAD-ADP-RSMA/M-RSMA/F-90
Order No. 2904790 (RSMA (male) > RSMA (female) 90)

Antenna splitter
5 GHz

RAD-ISM-5000-ANT-PAR-22-N
Order No. 5606174

RAD-ISM-2400-SPL-2-SMA
Order No. 2885595

RAD-ISM-2400-SPL-4-SMA
Order No. 2867856

5 GHz WLAN
Gain: 22 dBi
Connection: N (female)

For connecting up to four receivers


to an antenna
Accessories: 2 x termination resistor,
SMA (female) > N (male) adapter
Degree of protection: IP20

Vulcanizing
For external protection of adapters, splitters or
cable connections; watertight
Length: 3 m

* For use in the Ex area with the RAD-PIG-RSMA-N-EX/ATEX 2904788 adapter cable (see page 43).
PHoeNIX CoNTACT

41

Antenna cable
RSMA-N

RAD-PIG-RSMA/N-
Order No. 2903263 (0.5 m length)
Order No. 2903264 (1.0 m length)
Order No. 2903265 (2.0 m length)
Order No. 2903266 (3.0 m length)
Order No. 2702140 (5.0 m length)

Type EF 393

RAD-CAB-EF393-..M
Order No. 2867649 (3 m length)
Order No. 2867652 (5 m length)
Order No. 2867665 (10 m length)
Order No. 2885634 (15 m length)

Type EF 142

RAD-CAB-EF142-.. M
Order No. 2884512 (3 m length)
Order No. 2884525 (5 m length)
Connection: SMA (male) at both ends

Connection: N (male) at both ends

Connection: N (male) > RSMA (male)

Leaky cable (LCX)


2.4 GHz

Assembly tool (LCX)

Accessories (LCX)

FL LCX CABLE METER


Order No. 2884774

FL LCX TOOL
Order No. 2884981

Temperature: -40 +85C


Longitudinal attenuation: 19.8 dB/100 m
Coupling attenuation 95%: 89 dB

Planing tool

FL LCX CON-N-F
Order No. 2884965 (connector, N (female))
FL LCX 50-OHM
Order No. 2884978 (termination resistor, N (male))
FL LCX CLAMP
Order No. 2884994 (cable tie)

PSI-GSM/UMTS-ANT-OMNI-2-5
Order No. 2900982

PSI-GSM-STUB-ANT
Order No. 2313342

GSM/UMTS omnidirectional antenna for wall or


mast mounting
Gain: 2 dBi
5 m antenna cable with SMA round plug

Direct mounting on the device


Angled antenna plug
Installation in plastic control cabinets not visible
from the outside
Connection: SMA round plug

Mobile phone
Antennas

PSI-GSM/UMTS-QB-ANT
Order No. 2313371
TC ANT MOBILE/GPS
Order No. 2903590
GSM/UMTS antenna for mounting on a control
cabinet
With omnidirectional characteristics
2 m antenna cable with SMA round plug

42

PHoeNIX CoNTACT

Configuration stick

Configuration cable

Type EF 316

RAD-PIG-EF316-
Order No. 2867678 (1 m, MCX(m) > SMA(m))
Order No. 2867681 (50 cm, MCX(m) > N(m))
Order No. 2867694 (30 cm, N(f ) > SMA(m))
Order No. 2867704 (50 cm, N (f ) > N (m))
Order No. 2885618 (50 cm, SMA(m) > SMA(m))

Antenna barrier
for the Ex area

RAD-PIG-RSMA-N-EX/ATEX
Order No. 2904788
Thread: M25; zone 1 and 2; N (female) >
RSMA(male)
RAD-PIG-RSMA-N-EX/US
Order No. 2904789
Thread: 3/4" NPT; Class I, Div. 1, Grps. A, B,
C& D; Class II, Div.1, Grps. F & G;
N (female) > RSMA (male)

RAD-CONF-RF...
Order No. 2702122 (RF band 1, 900 MHz)
Order No. 2902814 (RF band 3, 2.4 GHz)
Order No. 2902815 (RF band 5, 2.4 GHz)
Order No. 2902816 (RF band 7, 2.4 GHz)
RAD-MEMORY
Order No. 2902828 (freely congurable)
Unique network addressing via plug-in
configuration memory for secure,
parallel operation of multiple networks

Sealing tape

RAD-TAPE-SV-19-3
Order No. 2903182
Vulcanizing
For external protection of adapters, splitters or
cable connections; watertight
Length: 3 m

RAD-CABLE-USB
Order No. 2903447
USB cable for diagnostics and configuration

Surge protection
2.4 and 5 GHz

CN-UB-70DC-6-SB (868/900 MHz)


Order No. 2803153
Connection: N (male) > N (female)
CN-UB-70DC-6-BB (868/900 MHz)
Order No. 2803166
Connection: N (female) at both ends
CN-LAMBDA/4-5.9-BB (2.4/5.2/5.8 GHz)
Order No. 2838490
Connection: N (female) at both ends

This adapter cable allows you to use selected


antennas in zone 2.

Antenna cable

PSI-CAB-GSM/UMTS
Order No. 2900980 (5 m)
Order No. 2900981 (10 m)
GSM/UMTS antenna extension cable, 10m length;
SMA (male) > SMA (female), impedance: 50Ohm

Angled adapter

Surge protection set

RAD-ADP-SMA/F-SMA/M-90
Order No. 2917324

CSMA-LAMBDA/4-2.0-BS-SET
Order No. 2800491

90 adapter for connecting the GSM/UMTS


antenna cable where space is restricted
SMA (female) > SMA (male)

Consisting of attachment plug with LAMBDA/4


technology as surge protection for coaxial signal
interfaces
Connection: SMA connector plug/socket

PHoeNIX CoNTACT

43

Always up-to-date, always available to you. Here


you'll find everything on our products, solutions
and service:

phoenixcontact.com

Product range

Printed in Germany

PHOENIX CONTACT 2014

Power supply units and UPS


Protective devices
Relay modules
Sensor/actuator cabling
Software
Surge protection and interference filters
System cabling for controllers
Tools
Wireless data communication

MNR 52001683/2014-03-05/05

PHOENIX CONTACT GmbH & Co. KG


32825 Blomberg, Germany
Phone: +49 (0) 52 35 3-00
Fax:
+49 (0) 52 35 3-4 12 00
phoenixcontact.com

Industrial communication technology


Industrial Ethernet
Installation and mounting material
Lighting and signaling
Marking and labeling
Measurement and control technology
Modular terminal blocks
Monitoring
PCB terminal blocks and
PCB connectors

ION02-14.004.L3

Cables and wires


Connectors
Controllers
Electronics housing
Electronic switchgear and
motor control
Fieldbus components and systems
Functional safety
HMIs and industrial PCs
I/O systems

You might also like