ETABS 2016 16.0.

License #*1ES7YK4AC6GBPC8

ETABS 2016 Concrete Frame Design


ACI 318-08 Column Section Design

Level

Element

2nd Floor

Column Element Details (Summary)


Section
Combo
Station
ID
ID
Loc

Unique
Name

C15

132

Envelope
All

C300X300

Length
(mm)

LLRF

Type

4650

Sway Special

4250

Section Properties
b (mm)

h (mm)

dc (mm)

Cover (Torsion) (mm)

300

300

56

27.3

Material Properties
Ec (MPa)

f'c (MPa)

Lt.Wt Factor (Unitless)

fy (MPa)

fys (MPa)

24855.58

21

275.79

275.79

Design Code Parameters


T

CTied

CSpiral

Vns

Vs

Vjoint

0.9

0.65

0.75

0.75

0.6

0.85

Design Pu

Axial Force and Biaxial Moment Design For Pu , Mu2 , Mu3


Design Mu2
Design Mu3
Minimum M2
Minimum M3
Rebar Area

Rebar %

kN

kN-m

kN-m

kN-m

kN-m

mm

105.0581

0.099

2.7573

2.5466

2.5466

900

Cm Factor

Axial Force and Biaxial Moment Factors


ns Factor
s Factor

K Factor

Effective Length

Unitless

Unitless

Unitless

Unitless

mm

Major Bend(M3)

1.082719

4250

Minor Bend(M2)

1.082719

4250

Shear Vu

Shear Design for Vu2 , Vu3


Shear Vc
Shear Vs

Shear Vp

Rebar Av /s

kN

kN

kN

kN

mm/m

Major, Vu2

1.874

47.2824

1.874

Minor, Vu3

15.6079

47.2824

15.6079

Joint Shear

Joint Shear Check/Design


Shear
Shear
Shear

Force

Vu,Top

Vu,Tot

Joint

Shear

Vc

Area

Ratio

kN

kN

kN

kN

cm

Unitless

Major Shear, Vu2

1.874

18.5903

349.3107

900

0.053

Minor Shear, Vu3

15.6079

160.1622

349.3107

900

0.459

Ermelita Residences Analyze 2016.EDB

Page 1 of 2

10/11/2016

ETABS 2016 16.0.0

License #*1ES7YK4AC6GBPC8

(6/5) Beam/Column Capacity Ratio


Major Ratio

Minor Ratio

0.093

0.783

Ermelita Residences Analyze 2016.EDB

Page 2 of 2