LEARNING FROM INCIDENTS
ACTION ALERT
GRP-AC-201203 CUT Deed
Retrieval of Corrosion Coupons from Pressurised Lines
Target audience for this alert
t= Personnel responsible for and managing corrosion inspection work
= Maintenance and Inspection Managers
= Assot Managers
What happened
On May 3" 2012, in a non-Shell operated joint venture, a team was removing @
corrosion monitoring instrument (corrosion coupon installed at the bottom of «
{905 pipeline ("6 o'clock" positon). At the time of this operation the line was
pressurised and operating at 74 ber.
The corrosion coupon retrieval operation was nearing completion when a sudden a
unbalanced release of pressure resulted in an uncontrolled outward movement of _Piue 1: Siveton before the incident
the outer barrel (piston) with the rotation handles cttached. Person 3 was hit on
the helmet/head by one of handles and fall injured
Why it happened
The investigation ofthis incident is not yet complete.
Lessons learned
Insight gained to date: tis understood that for botiom-oF ine applications
("6.0'¢ock') the assembly con be vlnerable to fouling due to corrosion product
seiling in low poins/ the botom- Fine and can drop down int the corrosion
coupon balancing path. This cn lood fo pressure imbalance within the rival
tool rosutng in an uncoirlled outward movement ofthe over bere (piston)
upon disengagement of he coupon threads Fae ME sos cer he nile
Adas Cel ede pr
‘While the incident investigetion is ongoing, itis recommended hat the following ‘Bun yar ce
ccion be considered os precautionary measures:
1. Stop all corrosion coupon relrivel operations on pressurised lines. When the investigation of this incident is
complete, subsequen' LF Alert [expected end May) wll communicate the learnings andl advise if his type of work
Prior tothe start of werk Contract Holders, with he support of Shell maintenance and inspection personne, are fo assess
‘whether contactors wh perform corosion coupon retrieval operajions on pressurised ines have a Competence
‘Assurance process for thar personnel and essure they are competent. This type of work sa specait operaion
normally corrected ou fo Orginal Equipment Mangfactrer (OEM approved contractors with cerified personnal
(Refer Shell HSSE & SP Control Framework Contractor HSSE Management Manval (requirement 3.3)}.