You are on page 1of 4

singla motors

karnal
SUBMERSIBLE MOTOR TEST REPORT AS PER IS 9283 : 1995

1 Insulation resistance t Before & After HV test one megohm.Mi

More than 1
MegaOhm

2 High Voltage Test

Withstood

V
A
Watts
rpm
Hz

:
:
:
:
:

415
12.61
1042
2943
49.22

V
A
Watts
160

:
:
:
:

246
73.26
18708
51.02

1.40

:
:
:
:
:
:
:
:
:
:

415
23.50
13145
2860
49.92
4.68
82.96
0.78
0.65
14.54

7 Temperature rise Test Current


A :
at rated voltage
Temp. Rise 35centigrade Max.
:
Cooling water temp. 45 centigrade Ma :

88.20
7.54
29.00

8 Temperature rise Test aCurrent


A :
85 % of rated voltage Temp. Rise 45centigrade Max.
:
Cooling water temp. 45 centigrade Ma :

24.62
14.98
29.00

9 Leakage Current Test aDeclaredmA Max.


Rated Voltage.

15.90

Motor should able to withstand 1.2 KV


for 5 sec.

3 No load running of motVoltage


Current
Power
Speed
Frequency
4 Locked rotor reading

Voltage
Current
Power input
Starting Torque in % of
Full Load Torque

5 Measurement of StatorStator resistance per phase at 26


degree centigrade
Resistance
6 Full load test

10 Vibration test :

Voltage
V
Current
A
Input Power
Watts
Speed at 50 Hz
rpm
Frequency
Hz
Slip
%
Nominal Efficienc
%
Power Factor Minimum
Product of P.F.& Effici. Min.
Loading Percenta
%

415
95.00
---2910
50.00
3.00
69.10
---------

29

N.A.

M/s SU PUMPS AMBALA CITY


PUMP PERFORMANCE TEST AS PER IS 8034 : 2002
Testing Date

Bore Size

Sr. No.

: 19315

Head

100.0 m

250.0 mm

Model

: SU9AB

Discharge

33.34 lps

Stage

: 5

Overall Effi.(%)

64.38 %

: S/D

Head Range

90.00 to

Volt
Motor No.

: 415
: 19315

Motor Rating
Current Max.

:
:

75.00 HP
95.00 A

Motor Eff.

: 87.0%
: 74%

Leakge Current

28.6

04/27/16

Delivery size

150.0 mm

Rated Speed

2910

CT ratio

rev/min Conn.

55.00 KW

Dawn draw

HEAD

V Head .

Total Head,

Head Over Vee Notch,

Dis.in lps.

Watt meter reading

Pumpset input

Frequency

Current,

Pumpset output

Discharge

Head

Pumpset Input

Overall Efficiency

Slip

Voltage

mA

Speed of Pump,

Sl No

Pump Eff.

110.0

rev/min

mm

l/s

KW

kW

Hz

kW

l/s

kW

1 3004 2.130

1.0

Corrected at Rated
Frequency 50 Hz

0.398 3.53 ### ###

44.100

### ###

72.58

2 2970 2.100 ### 0.214 95.31 ### ###

57.800

### ###

93.18

34.12 ### 91.51 ### 62.76

3.00

415

3 2974 2.080 ### 0.185 ### ### ###

56.400

### ###

90.90

34.00 ### 98.14 ### 64.12

2.89

415

4 2977 2.030 ### 0.162 ### ### ###

54.600

### ###

88.20

33.09 ### ### ### 64.47

2.79

415

5 2978 2.000 ### 0.145 ### ### ###

53.810

### ###

86.86

32.19 ### ### ### 63.63

2.76

415

6 2983 1.900 ### 0.116 ### ### ###

51.400

### ###

83.00

30.10 ### ### ### 62.34

2.61

415

7 3030 1.500 ### 0.000 ###

30.000

### ###

52.00

1.39

415

0.0

0.00

1.71 ### 3.37 ###

0.00 0.00 ### ###

4.15

2.12

415

0.00

Signature.

SUB.MOTOR TEST AS PER IS 9283 : 1995


Date
kW
Speed

42487
75.00
2910

Sl. No.
Voltage
Conn.

19315
415
S/D

Resistance Measurment
RR
YY
BB
1.39
1.4
1.42
Star : Avg. x 0.5
No Load
V
R
415
12.61
353
7.75

R/Phase
1.403
0.000
Delta : Avg. Resi.
Current Amp
Y
B
12.61
12.61
7.75
7.75

SPEED AT REDUCED VOLTAGE

240

Locked Rotor Test


CTR
1
Volts
Current
Power
V
A
W1
246
73.26
18708
123.59 Current @ 415 V
Full Load Test
Volts
Current
V
A
415
23.50
353
24.62

CTR

1
Power
W1
13145
12711

Min. Bore
Max. A
Lkg. mA

250
95.00
29

Model
Motor Eff.
Torque

300

Temp. T1
26

DELTA

Avg.
12.61
7.75

CTR
W1
1042
849

1
W2
0
0

Input kW
1042
849

Freq. Hz
49.22
49.02

CLOCK

2922

ANTI

2920

Hz

Current A
Input
kg.
0.300

73.26
Ini. Wt.
kg.
4.800

FLT
Final Wt.
kg.
4.500

1.788
Current A,41523.50
Input
Freq.
kW
Hz
13145
49.92
12711
49.89

@ 350
Speed
rpm
2855
2792

25.103
1
Load
Torque
kgm
Load Trq.
12.807
51.02
% of Full Load Current
24.62
OutPut
kW
10905
10207

Slip
Slip
%
4.68
6.73

Power
Factor
0.78
0.84

Prod. of
P.F. & Eff.
0.646
0.678

mega Ohm b) Phase to Phase More Than

High Voltage Test

Performed at 1200 Volts for 30 secs. and found :

Leakage Current :

15.90

mA

Cable Size :

4.00

Sq. mm

(1) Fix Loss


No Load I^2R50
No Load I^2R50
Fix Loss
Fix Loss
Full Load Cu Loss
Full Load I^2R50
Full Load I^2R50
Rotor Input :

% Minimum

Resistance R50
@ 50C
1.532

Comparesion
Time
DurationTemp.Amb.R_Hot (Avg.)Temp.Rise 35.00 Motor Eff.
hrs.
hrs.
T2 C
ohms
C
45.00
%
12.30 TO 14.30
2
29
1.46
7.54
45.00
82.96
14.30 TO 15.30
1
29
1.50
14.98
45.00
80.30
Insulation Resistance Test
a) Phase to Phase : More Than

SU9AB
69.10
160.0

3 m Long

300

O. K. / NOT O.K.

3 core flat cable

NLW - I^2R50
(3) Slip Loss
@ 415 243.63
@ 350 91.97
@ 415 798.37
(4) Stray Loss
@ 350 757.03R50 @415
I^2R50 1.576
@ 415 846.25
Total Losses
@ 350 955.52
FLW - (1) + (2)
@ 415 ###
Actual Output
@ 350 ###

Rotor Input x Slip


@ 415 538.31
@ 350 739.99
Rotor Input x 0.005
@ 415 57.50
@ 350 51.29
(1)+(2)+(3)+(4)
@ 415 ###
@ 350 ###
FLW - Total Losses
@ 415 10904.56
@ 350 10207.16

Speed
2943
2938
49.04
m Arm Lth.
% of Full

130.10
3.00
Loading
%
14.54
Speed @
50 Hz
rpm
2860
2798
mega Ohms

Rotor Input x Slip

Rotor Input x 0.005

FLW - Total Losses


10904.56
10207.16

You might also like