01.01.01.

010
2011
DSSY-X Series

Diko Elektrikli Cihazlar San. ve Tic. A.


www.diko.com.tr

DSSY-X SERIES

INDUSTRIAL TYPE
ELECTRIC WATER HEATERS
WITH ELECTRIC COMMAND PANEL
STANDART SPECIFICATIONS
OPTIONAL EQUIPMENTS AND REQUEST OPTIONS
PRODUCT DESCRIPTION
PLACE OF USAGE
CONNECTION DIAMETERS
DIMENSIONS AND CONNECTION HEIGHTS (DRAWING)
INSTALLATION HEIGHTS
PRODUCT DIMENSIONS AND WEIGHT SCHEDULE
EXAMPLE PRODUCT SPECIFICATION CHART
HEATING TIMES
MODEL CHART
ADVISED INSTALLATION SCHEMATIC

DSSY-X Serie
Industrial Type
Electric Water Heaters
Electric Command Panel
STANDART SPECIFICATIONS

Vertical
Capacity range between 125 5000 liters
Power rate between 10 600 KW
220-380-400-415-440 V
Temperature adjustment thermostat (090) C
Stainless steel heating elements Cr/Ni304
Thermometer
Safety thermostat
Heater group switches and signal lamps
Circulation pump switch and signal lamp
Heater contactor group /groups
Heater group fuse / fuses
Thermic magnetic main breaker and 24V.AC reduced command voltage (for 45 KW or more)
Leakage current relay (human life protection)
Power steps control
Electrical command panel with polyurethane cast gasket cover
Flap gate command panel (Facility to remove heating elements easily)
Temperature and pressure T&P relief valve
Max. Operating pressure : 8 bar
Electrostatic powder paint coated body
Magnesium Anode
Drain valve
2 years product guarantee
10 years spare part supply guarantee

up

OPTIONAL EQUIPMENTS and REQUEST OPTIONS

Horizontal
Special production between 5000 10.000 liter capacity range
Special production between 600 1000 KW power range
Incolloy type heating elements
Protection system against waterless operation
Audible and visual warning system against waterless operation
Protection system against overheating
Digital thermostat thermometer with contact
PLC control panel
Phase protective relay
Digital process control & command for electric circuit
(Microprocessor, protector & multimeter)
Safety switch for electric command panel
Rated temperature control system
Daily programmable time clock
Rock wool / Polyurethane (CFC Free) inner tank insulation
Hand-hole cleaning cover
Vacuum safety valve
Pressure reducer with manometer
Manometer on tank or manometer with contact
Expansion tank
Thermal surface preventive system
Dissinfective and preventive system against Legionella bacterium

up

STANDART EQUIPMENTS

___Temperature Adjustment Thermostat (090) C


Adjusting desired temperature value between (0-90)C is possible via this adjustment thermostat.
up

___ Stainless Steel Cr/Ni304 Quality or Incolloy Heating Elements


Single phase or 3Phase stainless steel water heaters with 6-8-9,5mm diameter, U pipe, MgO
isolation, Cr-Ni material and with various power rates.
Nicel_Chrom_Minco American alloy (Magnezyum Oksit) specially designed considering corrosive
surroundings. This incoloy heating elements are much more everlasting for areas with mildy water.
Operation life is being extenden and malfunction risk is being reduced with its low density between
(7,7511,63) Watt/cm2.
up

___Temperature Display : Thermometer


Placed on tank body or panel cover. Displays tank water temperature value. With capilary tube gas,
52mm diameter, pointer type and can read between 0-120C (tolerance between %+/-1C).
up

___Safety Thermostat
Provides tank protection via breaking electric circuit of the heaters unless tank water temperature
level passes over operating temperature value. Factory adjusted and sealed. This adjustment is
inconvertible.
up

___Heater Group Switches and Signal Lamps


Heater group switches placed on cover and being command manually.Operates as ON/OFF. 1
each for every heater group. Purpose of use is to take the groups into/out of the circuit .
Heater group signal lamps are placed on the group switches.Red light will be on incase the swithc is
in ON position. Thermostat will shut all the group lamps when tank water level reaches desired
temperature. This means hot water is ready for consumption.
up

___Circulation Pump Switch and Signal Lamp


Via this switch it is possible to command the pump from panel cover. Singlephase 220V command
output passes through pump fuse. There is one piece og signal lamp on the out-put of the switch
and phase and neutral is connected to connector.
up
5

___Heater Group Fuses


There are 3 pieces fuses for each heater exists in every heater group. These fuses breaks the
circuit to eliminate the faulty heater incase heater malfunctions
up

___Thermic Magnetic Main Breaker and 24V.AC Reduced Command Voltage


A thermic magnetic breaker which is suitable with the heater power of the panel placed to provide
protection for cable feed line and panel. This main breaker breaks the circuit incase short circuits
and excessive currents. It can operate manually with its latch. Diameter and isolation values of
command cables are lower according to energy cables. This disadvantage is being eliminated via
using devices with low voltage.
up

___Leakage Current Relay (Human Life Protection)


Heaters leaks current as miliamper as time goes by. This leakage current relay protects system and
human life against short circuits and touchings.
up

___Power Steps Control


Generally total power diveded in to 3 equal power value as 3 groups via switches placed on panel
cover. If all the switches are in ON position, tank will operate with maximum power. In summer
season this power will not be necessary, thus it is possible to control the heating power via shutting
down some of the switches.
up

___Temperature and Pressure T&P Relief Valve


T&P valve is a mechanical safety accessory against excessive heat and pressure. It discharges at
max. 99C and/or at max. 10,4bars.
up

OPTIONAL EQUIPMENTS and REQUEST OPTIONS

___Protection System Against Waterless Operation


This system stops the operation and starts to warn the operator with light and voice to protect the
heating elements incase the tank is empty or water level of the tank is low
up
___Audible and Visual Warning System Against Over Heating
Safety Thermostat will break the circuit incase the tank water temperature level will pass over the
limits, thus heating will stop. In this case this warning system will warn the operator with light and
voice.
up
___Digital Thermostat - Thermometer
Usage purpose of this digital thermostatic thermometer is to adjust the desired water temperature
value. nteger or decimal temperature value can be read directly from the screen.
up
___PLC Control Panel
Usage purpose of this programmable logic control panel is to provide easy function follow up of
the heating system. User can easily control and adjust the heating functions and follow function
faults from the control panel with digital thermostat-thermometer. Data adjustment access is
password locked.
up
___Microprocessor Based Digital Process Protector & Multimeter with Voltage and
Frequency Protection
Password locked device is being settled according to panel power and commence operation after
being locked via password. (DIKO AG-05)
up
___Safety Switch for Electric Command Panel
This switch provides energy cut-off before opening the tank panel cover in purpose of maintenance ,
test or malfunction. The panel cover can not be open unless the switch is being turned.
up

___Rated Temperature Control System


Provides the operation of the heater via temperature control instead of power control . t adjusts the
necessary power itself to stable the desired temperature value. System controls the circuit as to be
tristor and as to be with contactor.
up

___Hand-Hole Cleaning Cover


This cleaning cover permits the operator to access to the inner tank for periodical maintanences
up

___Vacuum Safety Valve


This is a mechanical safety valve which provides protection for system and installation pipes against
negative pressure (inner vacuum).
up

___Pressure Reducer With Manometer


This is an installation accessory which reduces the high installation input pressure to a suitable
value and shows the reduced pressure.
up

___Manometer on Tank _ Manometer with Contact


This installation accessory displays the inner tank pressure of the operating electrical water heater.
The models with contactor eleminates the heating operation at the adjusted pressure value.
up

___Expansion Tank
This is an installation accessory which absorbes expanded water and provide system protection.
up

___Thermal Surface Preventive System


This system is specially designed to prevent or at least to minimize the thermal sediments placed
bottom of the water heater. This thermal sediments come into being in areas with mildy and
agressive water and this factor negativelly effects the tank life. Thermal sediments are being
prevented and tank life is being extended via this system.
up

___Dissinfective and Preventive System Against Legionella Bacterium


Water storage systems, fresh water and waste water systems are ideal places for micro-organizms.
Among these micro-organizms, specially Legionella bacterium can pullulate easily in the water with
35-45C temperature. Also these bacteriums can live in 60C and can be re-active for pullulation
when the ambient circumstances will turn suitable. An additional preventive system against such
bacteriums and microorganizms is necessary for all hot water store systems and according to this
our specially developped additional preventive system will protect you and your product
automatically.
up

PRODUCT DESCRIPTION
DSSY-X Serie electric water heaters are monoblock units with their electric command panel
and inner tank. Generally, electric command panel of these units developped inorder to heat
the water inside of the inner tank, in one hour. It will be enough to inform us incase of a shorter
heating time request.
Electric command panel of DSSY-X Serie equipped with first quality electric components. The
product will be ready to operate after performing the energy supply connections. Command
panel electric installation and design is user friendy and easily accessable.
Authorized technician can easily operate and follow up the functions of the system. Functions
like water temperature value, operation of the heater groups, water level and over heating
status (if requested) can be obserbed from the panel.
DSSY-X Serie vertical round, floor standing electrical water heaters can achive a capacity of
10.000L and 600KW. This valuable serie is specially developped according to users special
requirements to provide the desired hot water within the shortest time and via most reliable
way.
up

PLACE OF USAGE
Industrial Type Applicatioons
Hospitals
Hotels
Factories
Construction Sites
GYMs
Textile
Chemistry
Army Bases

up

10

DSSY-X SERIE
CONNECTION DIAMETERS
MODEL

CAPACITY
(liter)

DSSY-125X.___

HEATER POWER
(KW)

N1

N2

N3

N4

125

DSSY-150X.___

150

DSSY-200X.___

200

DSSY-250X.___

250

DSSY-300X.___

300

DSSY-400X.___

400

P <= 45

DSSY-500X.___

500

P <= 45

DSSY-750X.___

750

DSSY-1000X.___

1000

DSSY-1250X.___

1250

DSSY-1500X.___

1500

DSSY-2000X.___

2000

DSSY-2500X.___

2500

DSSY-3000X.___

3000

DSSY-4000X.___

4000

DSSY-5000X.___

5000

P <= 120

P <= 120

P <= 120

up

11

DSSY-X SERIE INDUSTRIAL TYPE ELECTRIC WATER HEATERS


DIMENSIONS AND CONNECTION HEIGHTS

SYMBOLS
D1
D2
HN1
HN2
HN3
HN5
H
NOTE: N6 not exists on Stainless Steel Products.

up

12

: Outer Body Diameter


: Inner Body Diameter
: Cold Water Input Height
: Drain Valve Height
: Re-Circulation Height
: T&P Safety Valve Height
: Product Height

DSSY-X SERIE
INDUSTRIAL TYPE ELECTRIC WATER HEATERS
INSTALLATION HEIGHTS
MODEL

Capacity
(litre)

D1
(mm)

D2
(mm)

HN1=HN2
(mm)

HN3
(mm)

HN5
(mm)

H
(mm)

DSSY-125X.___

125

480

400

200

555

920

1110

DSSY-150X.___

150

480

400

200

655

1120

1310

DSSY-200X.___

200

580

500

205

570

945

1140

DSSY-250X.___

250

580

500

205

700

1205

1400

DSSY-300X.___

300

580

500

205

825

1455

1650

DSSY-400X.___

400

700

640

229

699

1179

1398

DSSY-500X.___

500

700

640

229

854

1489

1708

DSSY-750X.___

750

830

750

325

950

1585

1900

DSSY-1000X.___

1000

980

900

330

900

1480

1800

DSSY-1250X.___

1250

1038

958

315

965

1625

1930

DSSY-1500X.___

1500

1038

958

315

1140

1975

2280

DSSY-2000X.___

2000

1300

1200

360

1000

1650

2000

DSSY-2500X.___

2500

1450

1350

360

1025

1700

2050

DSSY-3000X.___

3000

1450

1350

360

1200

2050

2400

DSSY-4000X.___

4000

1800

1700

155

980

1815

1960

DSSY-5000X.___

5000

1800

1700

155

1200

2255

2400

Diko reserves the right of changing the models and dimensions without announcing.

up
13

DSSY-X SERIE
INDUSTRIAL TYPE ELECTRIC WATER HEATERS
DIMENSION AND WEIGHT SCHEDULE
MODEL

PG
(mm)

PD
(mm)

PY
(mm)

Net Weight
(kg)

Gross Weight
(kg)

Packing Dims.
(cm)

DSSY-125X.___

300

300

700

66

90

60x90x125

DSSY-150X.___

300

300

700

75

103

60x90x145

DSSY-200X.___

300

300

700

82

114

70x100x128

DSSY-250X.___

300

300

700

97

133

70x100x154

DSSY-300X.___

300

300

700

112

150

70x100x179

DSSY-400X.___

300

300

700

127

190

82x112x154

DSSY-500X.___

450

300

900

151

199

82x112x185

DSSY-750X.___

450

300

900

229

299

95x125x209

DSSY-1000X.___

450

390

900

350

442

110x149x199

DSSY-1250X.___

450

390

1200

404

505

116x155x212

DSSY-1500X.___

450

390

1200

482

591

116x155x247

DSSY-2000X.___

450

390

1200

610

737

142x181x219

DSSY-2500X.___

700

450

1400

739

884

157x202x224

DSSY-3000X.___

700

450

1400

826

1003

157x202x259

DSSY-4000X.___

800

450

1400

1210

1419

192x237x215

DSSY-5000X.___

800

450

1800

1338

1629

192x237x259

Diko reserves the right of changing the models and dimensions without announcing.

up
14

DSSY-X SERIE
4000 Liter (1057 US Gallon) & 5000 Liter (1321 US Gallon)
MODEL

CAPACITY
(liter)

POWER
(KW)

HEATER
QUANTITY (pcs)

HEATER
POWER (KW)

HOT WATER
FLOW
(Liter/Hour)
18C-55C
(64F-131F)

DSSY-4000X.60

4000

60

10

1395

172,1

380-400-415-440

50-60

DSSY-4000X.72
DSSY-4000X.90
DSSY-4000X.108
DSSY-4000X.120
DSSY-4000X.160
DSSY-4000X.180
DSSY-4000X.210
DSSY-4000X.240

4000
4000
4000
4000
4000
4000
4000
4000

72
90
108
120
160
180
210
240

9
9
12
12
16
18
21
24

8
10
9
10
10
10
10
10

1674
2092
2510
2789
3719
4184
4881
5578

143,4
114,7
95,6
86,0
64,5
57,4
49,2
43,0

380-400-415-440
380-400-415-440
380-400-415-440
380-400-415-440
380-400-415-440
380-400-415-440
380-400-415-440
380-400-415-440

50-60
50-60
50-60
50-60
50-60
50-60
50-60
50-60

HEATING TIME
(minutes)

VOLTAGE
OPTIONS (V)

FREQUENCY
(Hz)

179,3
143,4
119,5
107,6
80,7
71,7
61,5
53,8

380-400-415-440
380-400-415-440
380-400-415-440
380-400-415-440
380-400-415-440
380-400-415-440
380-400-415-440
380-400-415-440

50-60
50-60
50-60
50-60
50-60
50-60
50-60
50-60

MODEL

CAPACITY
(liter)

POWER
(KW)

HEATER
QUANTITY (pcs)

HEATER
POWER (KW)

HOT WATER
FLOW
(Liter/Hour)
18C-55C
(64F-131F)

DSSY-5000X.72
DSSY-5000X.90
DSSY-5000X.108
DSSY-5000X.120
DSSY-5000X.160
DSSY-5000X.180
DSSY-5000X.210
DSSY-5000X.240

5000
5000
5000
5000
5000
5000
5000
5000

72
90
108
120
160
180
210
240

9
9
12
12
16
18
21
24

8
10
9
10
10
10
10
10

1674
2092
2510
2789
3719
4184
4881
5578

HEATING TIME
(minutes)

VOLTAGE
OPTIONS (V)

FREQUENCY
(Hz)

Diko reserves the right of changing the models and dimensions without announcing.

up
15

DSSY-X SERIE
HEATING TIMES
MODEL

10 KW

15 KW

20 KW

22.5 KW

30 KW

45 KW

60 KW

75 KW

DSSY-125X
DSSY-150X
DSSY-200X
DSSY-250X
DSSY-300X
DSSY-400X
DSSY-500X
DSSY-750X
DSSY-1000X
DSSY-1250X
DSSY-1500X
DSSY-2000X
DSSY-2500X
DSSY-3000X
DSSY-4000X
DSSY-5000X

32.3
38.7
51.6
64.5
77.4
103.3
129.1
-

21.5
25.8
34.4
43.0
51.6
68.8
86.0
129.1
-

25.8
32.2
38.7
51.6
64.5
96.8
129.1
-

28.7
34.4
45.9
57.4
86.0
114.7
143.4
-

25.8
34.4
43.0
64.5
86.0
107.6
129.1
172.1
-

22.9
28.7
43.0
57.4
71.7
86.0
114.7
143.4
172.1
-

21.5
32.3
43.0
53.8
64.5
86.0
107.6
129.1
172.1
215.1

25.8
34.4
43.0
51.6
68.8
86.0
103.3
137.7
172.1

MODEL

90 KW

120 KW

150 KW

180 KW

200 KW

240 KW

260 KW

300 KW

DSSY-750X

21.5
28.7
35.9
43.0
57.4
71.7
86.0
114.7
143.4

21.5
26.9
32.3
43.0
53.8
64.5
86.0
107.6

21.5
25.8
34.4
43.0
51.6
68.8
86.0

21.5
28.7
35.9
43.0
57.4
71.7

25.8
32.3
38.7
51.6
64.5

21.5
26.9
32.3
43.0
53.8

24.8
29.8
39.7
49.6

21.5
25.8
34.4
43.0

DSSY-1000X
DSSY-1250X
DSSY-1500X
DSSY-2000X
DSSY-2500X
DSSY-3000X
DSSY-4000X
DSSY-5000X

Mentioned heating times are calculated consedering 37C temperature difference between input&output and without consumption. Heating times are valid only for mentioned Total Heater Power. Fort his
chart, different KW values will efect only the heating time. Please ask for information with regard to different capacity and KW requests.

up

16

DSSY-X SERIE
MODEL CHART
125
150
200
250
300
400
500
750
1000
1250
1500
2000
2500
3000
4000
5000

750
1000
1250
1500
2000
2500
3000
4000
5000

10 KW

15 KW

20 KW

22.5 KW

30 KW

45 KW

60 KW

75 KW

DSSY-125X.10
DSSY-150X.10
DSSY-200X.10
DSSY-250X.10
DSSY-300X.10
DSSY-400X.10
DSSY-500X.10
-

DSSY-150X.15
DSSY-200X.15
DSSY-250X.15
DSSY-300X.15
DSSY-400X.15
DSSY-500X.15
DSSY-750X.15
-

DSSY-200X.20
DSSY-250X.20
DSSY-300X.20
DSSY-400X.20
DSSY-500X.20
DSSY-750X.20
DSSY-1000X.20
-

DSSY-200X.22.5
DSSY-250X.22.5
DSSY-300X.22.5
DSSY-400X.22.5
DSSY-500X.22.5
DSSY-750X.22.5
DSSY-1000X.22.5
DSSY-1250X.22.5
-

DSSY-250X.30
DSSY-300X.30
DSSY-400X.30
DSSY-500X.30
DSSY-750X.30
DSSY-1000X.30
DSSY-1250X.30
DSSY-1500X.30
DSSY-2000X.30
-

DSSY-400X.45
DSSY-500X.45
DSSY-750X.45
DSSY-1000X.45
DSSY-1250X.45
DSSY-1500X.45
DSSY-2000X.45
DSSY-2500X.45
DSSY-3000X.45
-

DSSY-500X.60
DSSY-750X.60
DSSY-1000X.60
DSSY-1250X.60
DSSY-1500X.60
DSSY-2000X.60
DSSY-2500X.60
DSSY-3000X.60
DSSY-4000X.60
DSSY-5000X.60

DSSY-750X.75
DSSY-1000X.75
DSSY-1250X.75
DSSY-1500X.75
DSSY-2000X.75
DSSY-2500X.75
DSSY-3000X.75
DSSY-4000X.75
DSSY-5000X.75

90 KW

120 KW

150 KW

180 KW

200 KW

240 KW

260 KW

300 KW

DSSY-750X.90
DSSY-1000X.90
DSSY-1250X.90
DSSY-1500X.90
DSSY-2000X.90
DSSY-2500X.90
DSSY-3000X.90
DSSY-4000X.90
DSSY-5000X.90

DSSY-1000X.120
DSSY-1250X.120
DSSY-1500X.120
DSSY-2000X.120
DSSY-2500X.120
DSSY-3000X.120
DSSY-4000X.120
DSSY-5000X.120

DSSY-1250X.150
DSSY-1500X.150
DSSY-2000X.150
DSSY-2500X.150
DSSY-3000X.150
DSSY-4000X.150
DSSY-5000X.150

DSSY-1500X.180
DSSY-2000X.180
DSSY-2500X.180
DSSY-3000X.180
DSSY-4000X.180
DSSY-5000X.180

DSSY-2000X.200
DSSY-2500X.200
DSSY-3000X.200
DSSY-4000X.200
DSSY-5000X.200

DSSY-2000X.240
DSSY-2500X.240
DSSY-3000X.240
DSSY-4000X.240
DSSY-5000X.240

DSSY-2500X.260
DSSY-3000X.260
DSSY-4000X.260
DSSY-5000X.260

DSSY-2500X.300
DSSY-3000X.300
DSSY-4000X.300
DSSY-5000X.300

Diko reserves the right of changing the models without announcing. Please ask for information with regard to different capacity and KW requests.

up

17

up

18

Diko Elektrikli Cihazlar San. ve Tic. A..


mes San. Sitesi A Blok. 101 Sok. No:8
Y.Dudullu / stanbul
www.diko.com.tr

19