Technical Unit

Sand Control Tools- Gravel Pack and Frac Pack Packers

Unit No. TU 5632


September 13, 2011
Rev. I
Page 1 of 12

SC-2 Packer
Product Family H48807

Table of Contents
Description ..............................................................................1
Dimensional Data, Sizes 66-32 - 70-40 ............................... 8
Features and Benefits ............................................................2
Dimensional Data, Sizes 76-32, 76-40, and 96-47 .............. 8
Conversion To Bridge Plug .....................................................3
Dimensional Data Drawing K00-299TUP01,
Operating Procedure ..............................................................3
Sizes 96-40 and 107-60 ...................................................... 9
Setting on Tubing ...................................................................3
Dimensional Data Drawing 641-493-1TU,
Setting Procedure ...................................................................3
Sizes 86-40 and 96-60 ...................................................... 10
Setting on Electric Line ...........................................................4
Dimensional Data, Size 86-40 ........................................... 11
Retrieving Instructions ............................................................5
Dimensional Data, Size 96-60 ........................................... 11
SC-2 Packer (Product Family H48807)
CK Components for SC-2 Packer (Product Family H48807)
Dimensional Data Drawing 662-476-1TU,
Dimensional Data Drawing 641-141TU ............................. 12
Sizes 45-25 thru 76-40, and 96-47 ......................................7
Dimensional Data, Sizes 50-26 - 107-60 ........................... 12
Dimensional Data, Sizes 45-25 - 55-26 ...............................7

Description
The SC-2 packer is a fully retrievable, high-performance retainer production packer. Although the
packer was originally designed for premium gravel pack applications, it may also be used as a standard
completion packer in wells where a premium retrievable production packer is required.
The SC-2 packer is fully compatible with standard Baker Hughes sealing accessories, including retrievable and expendable plugs.
Refer to the specifications guide in the unit 5750, for packer/accessory size and packer size/model
availability.

This document is and contains unpublished, copyrighted and confidential information of Baker Hughes, and is revealed for limited purposes only. This document is the property
of Baker Hughes and is to be returned to Baker Hughes on request and may not be reproduced, used or disclosed to persons not having a need to know consistent with the
purpose of the document, without the written consent of Baker Hughes. This document is not rented, loaned or sold, either alone or in conjunction with equipment or product.
9/13/11 Baker Hughes Incorporated.

WARNING
Use of Baker Hughes equipment contrary to
manufacturers specifications may result in
property damage, serious injury or fatality.

Features and Benefits

All components, with the exceptions shown in


the chart below, satisfy NACE standard
MR-0175 for H2S service. Rated in standard
service to withstand pressures from above and
below to 7,500 psi and bottomhole
temperatures to 350F (maximum 300F with
nitrile packing element)
Size
Non H2S Parts *
45-25
Body Bottom Sub Lower Cone
50-26
Bottom Sub
66-32
Lower Cone
70-40
Upper Cone
86-40
Bottom Sub
96-60
Bottom Sub
*These parts must be replaced with highstrength CRA
parts when an H2S packer is required or packer
ratings decrease.

NOTE: 110 MYS material is recommended for use on


any SC-2 packer body used in CK fraq applications.
NOTE: The SC-2 packer is furnished with a 90 hard
nitrile packing element (non-H2S). Specify or indicate
well conditions expected if other than nitrile is required.

Short overall length facilitates easy running and


retrieving through doglegs and tight spots
Single, self-energizing, cup-forming packing
element for repeated low and high differential
pressure reversals
Packing element totally enclosed by chemically
resistant, zero extrusion, backup system to
ensure extended downhole life
Hydraulically operated, mechanical interlock
incorporated into the setting sleeve, preventing
the setting of the packer during retrieval should
it be impossible to reach setting depth (refer to
illustrations in the back of this unit)
Cast iron construction above the slips to
enhance emergency milling of the packer
should it be impossible to retrieve by
conventional methods
Drawing 662-476-1

Unit No. TU 5632


September 13, 2011
Page 2 of 12

Rev. I

This document is and contains unpublished, copyrighted and confidential information of Baker Hughes, and is
revealed for limited purposes only. This document is the property of Baker Hughes and is to be returned to Baker
Hughes on request and may not be reproduced, used or disclosed to persons not having a need to know consistent
with the purpose of the document, without the written consent of Baker Hughes. This document is not rented, loaned
or sold, either alone or in conjunction with equipment or product. 9/13/11 Baker Hughes Incorporated.

Conversion To Bridge Plug


The B expendable plug (product family no.
H65640) can be used to convert the SC-2 packer
to a temporary bridge plug, except 96-40 and 10760.
NOTE: B expendable plug, (product family H66540) is
limited to 7,500 psi.

Expendable Plug Installation


For complete information, refer to the units
from Baker Hughes on expendable plugs.
1. Remove bottom sub.
2. Remove brass shear screws and slide collet
support from inside collet.
3. Insert expendable plug (latch release end first)
through bottom end of collet.
4. Slide collet support into collet and install brass
shear screws.
5. Replace bottom sub.
NOTE: The expendable plug must be pushed out of
the packer bore before the packer can be retrieved
from the well. The retrieving tool can be used for this
purpose if the packer is to be retrieved at the same
time the plug is to be pushed out.

Operating Procedure
Setting on Tubing
When used in a one-trip gravel pack application, the SC-2 packer is run with the setting and
cross-over tool listed in the tubing setting compatibility and force analysis table. When setting the
SC-2 packer on tubing in standard applications,
the setting tool shown in the table is used with a hydro-set adapter kit.

Setting Procedure
1. Packers should be set as close to neutral
weight as possible. Maximum recommended
set-down weight is 2,000 lb for sizes 45-25 and
50-26, and 5,000 lb for larger sizes.
2. Raise pressure to P1 (refer to table footnote )
and hold for 5 minutes.
3. Bleed pressure to zero.
4. Raise pressure to P2 and hold for 5 minutes.
5. Bleed pressure to zero.
6. Establish neutral weight at the packer, if not already in this condition.
7. Raise pressure to P3 and hold for 15 minutes.
CAUTION!
P3 is a minimum pressure. If the ball seat
shears at a lower pressure, drop the backup
ball and pressure to P3 .
NOTE: In low bottomhole pressure wells, the
differential pressure between tubing hydrostatic
pressure and pressure below the packer will stress
the ball seat shear system. However, it will not
cause differential pressure and setting force in the
setting tool. In such situations, instances of early
ball seat shearing can be minimized between the
time the setting ball reaches the ball seat and the
time the setting procedure is completed. In severe
fluid loss situations, it may be advisable to drop the
backup ball without first using the primary ball.
However, in this instance, it is necessary to have a
system with positive control over fluid loss while in
the reverse circulation mode in order to be able to
reverse out the backup ball.

This document is and contains unpublished, copyrighted and confidential information of Baker Hughes, and is
revealed for limited purposes only. This document is the property of Baker Hughes and is to be returned to Baker
Hughes on request and may not be reproduced, used or disclosed to persons not having a need to know consistent
with the purpose of the document, without the written consent of Baker Hughes. This document is not rented, loaned
or sold, either alone or in conjunction with equipment or product. 9/13/11 Baker Hughes Incorporated.

Unit No. TU 5632


September 13, 2011
Rev. I

Page 3 of 12

Tubing Setting Compatibility and Force Analysis


Packer
Size

Crossover
Tool Size

Hydro-Set
Adapter Kit
Size

45-25

20-25

20SCA-30

Hydraulic
Setting Tool
Size

Model

20

B-1

Setting Pressure (psi)


P1

P2

P3

900

1,200
2,000
1,900
2,100
2,000
2,200
2,300
2,000
2,300
2,000
2,300

1,500
2,500
2,400
2,600
2,500
2,800
3,000
2,500
3,000
2,500
3,000

Absolute
Max.
2,000
3,000
2,900
3,100
3,500
3,800
4,200
3,500
4,200
3,500
4,200
5,500
5,400
4,200
5,500
5,400
Max.

Setting Force (lb)


Min.
26,000

Absolute
Max.
35,000

Max.

1,500
HT
43,000
52,000
HP
1,800
B-1
1,500
40
55-26*
40-26
HT
1,700
HP
1,800
49,000
69,000
B-1
1,500
66A2-32
66
HP
1,800
40
B-1
1,500
66A4-32
80-32
HP
1,800
70-32
SC
76-32
70
HP
1,900
2,500
3,100
50,000 68,000 88,000
70-40
SC
80-40
76-40
HP
SC
86-40
120-40
86
1,900
2,500
3,100
3,500
5,500
70,000 78,000 123,000
HP
SC
96-40
190-40
HP
1,300
1,800
2,900
3,500
5,500
65,000 78,000 123,000
SC
86
96-47
190-47
HP
SC
5,500
78,000 90,000 123,000
96-60**
198-60
190-60
HP
1,500
2,500
3,500
4,000
107-60
218-60
210-60
107
SC
4,100
125,000 143,000 147,000
When using setting tools other than those listed, P1, P2, and P3 should be the pressures required to yield 60%, 80%, and 100% of the
minimum setting force required. Other than the compression recommended in step 1 in the operating procedures section, pressure alone
should be used to set the SC-2 packers. Do not exceed absolute maximum setting force for the packer.
* 55A2-26: use size 20 B-1 hydraulic setting tool and follow the size 40 setting pressure Specifications, or use size 40 HT hydraulic setting
tool as specified.
** Also 96-47 SC-2FT PZM packer.
50-26

20-26

8. Bleed pressure to zero. Pressure test and anchor test packer as necessary. The setting tool
should be released and pulled from the packer
at this point to prevent pressure surges to the
formation when the ball seat shears.
9. Slowly increase pressure to shear ball seat. Do
not exceed absolute maximum setting pressure
before releasing setting tool from packer.
CAUTION!
Exceeding absolute maximum setting pressure
with the setting tool still connected to the
packer may exceed limitations of the packer or
the casing in certain applications.

Setting on Electric Line


NOTE: It is recommended that the SC-2 packer be set
on tubing at temperatures below 175F.

Unit No. TU 5632


September 13, 2011
Page 4 of 12

Rev. I

The SC-2 can be run and set on electric line


only under certain conditions using the B wireline adapter kit (product family H43809) and the E4 wireline pressure setting assembly (product
family H43702). Contact tech services and/or refer
to field bulletin ENG-HOU-004-01 for specific information.
NOTE: Any packer with a minimum setting force greater
than 50,000 lb cannot be set on electric line. The 86-40,
96-40, 96-47, 96-60, and 107-60 SC-2 packers cannot
be set on electric line.

CAUTION!
When setting the SC-2 packer with the E-4
pressure setting assembly, the slow set power
charge (product family no. H43766) must be
used.

This document is and contains unpublished, copyrighted and confidential information of Baker Hughes, and is
revealed for limited purposes only. This document is the property of Baker Hughes and is to be returned to Baker
Hughes on request and may not be reproduced, used or disclosed to persons not having a need to know consistent
with the purpose of the document, without the written consent of Baker Hughes. This document is not rented, loaned
or sold, either alone or in conjunction with equipment or product. 9/13/11 Baker Hughes Incorporated.

The assembly, running and setting procedures


on electric line are essentially identical to those
used when running the D or DA retainer production packer. Refer to unit on B wireline adapter
kit for the wireline setting tools required to set the
SC-2 packer.

the packing element. The pickup shoulder on the


body then contacts the lower gage ring, picking up
the upper cone and slip cage and pulling the slips
off the lower cone. Finally, the upper end of the collet contacts the lower cone and picks up the bottom
of the packer.

NOTE: At no time should anything be run through the


SC-2 packer that has a square upfacing shoulder.
Pulling this back up through the packer could
inadvertently shear the collet support, thus releasing the
packer.

Should the packer have trouble moving up the


hole, release the retrieving tool by pulling a slight
upstrain and rotating fifteen [15] turns to the right.
This simultaneously releases the safety sub and
latch of the retrieving tool, allowing it to be pulled
from the packer.

Retrieving Instructions
The packer is retrieved with a S-1 retrieving
tool (product family H48853). Refer to the unit on
retrieving tool for the correct size.
CAUTION!
For proper retrieving operation, the S-1
retrieving tool must pass through and extend
below the packer. When running accessory
equipment on the packer, the ID immediately
below the packer must be able to accept the
retrieving tool. Refer to the unit on retrieving
tool for complete dimensional information.
Locate the retrieving tool in the packer with
10,000 lb set-down weight to ensure that the catch
sleeve and latch of the retrieving tool are in their
appropriate positions. Pick up 14,000- to
15,000-lb to engage the catch sleeve and shear
the collet support, allowing it to move up. Continued upward movement is transmitted to the collet
and packer body, causing the collet fingers to deflect inward and releasing the body and collet.
As the body moves upward, the shoulder on the
top sub picks up the setting sleeve and releases

The area above the packer should be thoroughly washed and the retrieving tool restabbed into the
packer. The entire pickup load is then transmitted
to the top of the packer. jarring can then be applied.
Once the packer is fully released, it should be
pulled slowly for the first few stands to give the
packing element an opportunity to decompress.
If the packer cannot be retrieved with the retrieving tool, the CJ milling tool (product family
H75706) with the correct shoe size may be run to
recover the packer.
NOTE: If the CJ milling tool is run into the well, an
attempt should be made to release the packer with the
CJ milling tool. If the packer does release when the
attempt is made with the CJ milling tool, the packer and
the gravel pack extension or other tailpipe may be
retrieved on the CJ milling tool. If normal releasing of
the packer cannot be carried out, the new SC-2 packer
may be milled up in approximately the same time as a
comparably sized permanent packer.

This document is and contains unpublished, copyrighted and confidential information of Baker Hughes, and is
revealed for limited purposes only. This document is the property of Baker Hughes and is to be returned to Baker
Hughes on request and may not be reproduced, used or disclosed to persons not having a need to know consistent
with the purpose of the document, without the written consent of Baker Hughes. This document is not rented, loaned
or sold, either alone or in conjunction with equipment or product. 9/13/11 Baker Hughes Incorporated.

Unit No. TU 5632


September 13, 2011
Rev. I

Page 5 of 12

Performance Chart
Packer
Rating Size

Pressure Rating (psi)


Standard and H2S Service
Floating Seals Floating Seals in
Packer Plug
in Packer
Seal Bore Ext.
in Packer
Above Below Above Below Above Below
7,500
8,000
7,800
7,200
7,000
8,000
6,600
5,400
8,000
7,200
5,600
8,000
8,000
6,700
7,700
6,400
7,100
6,000
6,400
7,300
7,300
5,500
5,900
8,000
6,700
7,700
8,000
8,000
6,400
7,100
6,000
6,400
7,300
7,300
5,500
7,800
8,000
8,000
8,000
7,500
7,500
8,000
7,300
7,200
7,800
7,200
7,000
8,000
7,500
8,000
7,300
7,000
6,600
6,900
6,800
6,300
7,000
5,400
6,500
4,800
5,300
6,200
7,900
7,900
4,800
6,100
7,700
7,700
4,800
7,500
7,000
7,400
6,800
7,300
7,500
6,700
7,100
6,500
6,900
6,300
7,500
6,200
7,400
6,800
7,300
5,900
5,100
7,100
5,800
6,800
5,600

Packing
Element
Temp. Anchored Seals
Rating
in Packer
(oF)
Above Below

45A-25
45B-25
45C-25
50A-26
50B-26
55A2-26
55A4-26
55B-26
55C-26
55A2-32x26
55A4-32x26
55B-32x26
55C-32x26
66A2-32
66A4-32
70A2-32
70A4-32
70B-32
70C-32
70A4-40
70B-40
70B2-40
70C-40
76A2-32
76A3-32
Ambient76A4-32
350
76B2-32
76B4-32
76A2-40
76A3-32
76A4-40
76B2-40
76B4-40
86A-40
86B-40
96A-40
96A2-40
96A4-40
96B-40
96A-47
96A2-47
96A4-47
96B-47
96A-60
96B-60
96B2-60
96C-60
96C2-60
96C4-60
107A2-60
107A4-60

8,000

7,300

8,000

7,900
7,700

7,500

7,500
7,500

7,400
7,000

7,500
7,300

7,500
7,400
7,000

7,500

6,800
6,700
6,600
6,500
6,800
6,700
6,600
6,500

5,400
7,500

6,800

5,900

7,500

7,500

6,900
6,700
6,500
6,300
6,900
6,700
6,500
6,300
6,100
6,000
5,800
5,700
5,600
5,500

Tailpipe (lb)
Expendable
Plug in Tail Pipe
Plug in Packer
Above Below Above Below
7,500
7,500
7,800 7,200 7,800
7,200
7,000
7,000
5,400

6,600

8,000

7,500

5,300

7,500

6,600
6,400
6,000
5,500
6,600
6,400
6,000
5,500
8,000
7,500
7,200
7,000
6,600
6,300
5,300
5,000
4,800
4,800
7,000
6,800
6,700
6,500
6,300

5,900

5,500

8,000

7,500

5,300

7,500

5,500
7,800
7,500
7,200
7,000
6,600
6,300
5,300
5,000
4,800
4,800
7,000
6,800
6,700
6,500
6,300

7,500

7,500

7,500

7,300

7,500

6,800
6,700
6,500
6,300
6,800
6,700
6,500
6,300

5,400

6,500

71,000

55,000

93,000

40,000

115,000

50,000

167,000

140,000

211,000

122,000

162,000

72,000

5,900

5,100

7,300

Net

5,900

5,100

6,900
6,700
6,500
6,300
6,900
6,700
6,500
6,300

Run in
Max.

5,900

162,000

183,000

132,000

373,000

295,000

400,000

277,000

291,000

227,000

477,000

328,000

NOTE: While running in the top sub, body, collet, and bottom sub are subjected to, and will support, this tensile load; however, the joint strength of the running/setting
tools and companion equipment must also be taken into consideration when running long liners below the packer.
NOTE: The run in maximum tailpipe rating may be carried in the hole on the packer but prior to setting the packer any tailpipe weight in excess of the net tailpipe
rating must be relieved through slack-off on sump packer, horizontal positioning, etc.

Unit No. TU 5632


September 13, 2011
Page 6 of 12

Rev. I

This document is and contains unpublished, copyrighted and confidential information of Baker Hughes, and is
revealed for limited purposes only. This document is the property of Baker Hughes and is to be returned to Baker
Hughes on request and may not be reproduced, used or disclosed to persons not having a need to know consistent
with the purpose of the document, without the written consent of Baker Hughes. This document is not rented, loaned
or sold, either alone or in conjunction with equipment or product. 9/13/11 Baker Hughes Incorporated.

Dimensional Data Drawing 662-476-1TU, Sizes 45-25 thru 76-40, and 96-47

Dimensional Data, Sizes 45-25 - 55-26


Refer to Drawing 662-476-1TU.

4-in. NU Tbg Thd


3-5/8 Stub Acme

4.765

4.945
4.485
4.223
4.093
3.947

4.475
10.49
31.84
54.72
4.073
10.06
31.56
51.97

55C-26
4.593

55B-26
55A4-26
55A2-26
Size
50B-26
50A-26
45C-25

4.475
4.073

2.687
2.750

3-1/4 LH Sq Thd

Rev. I

Page 7 of 12

Unit No. TU 5632


September 13, 2011

A
B
C
D
E
F
G
H
X
Y

3.817

45B-25
3.812
3.870
2.500
2.562
3.812
8.61
28.31
53.95
2-7/8 LH Sq Thd
3-7/16 Stub Acme
45A-25
Dim.

This document is and contains unpublished, copyrighted and confidential information of Baker Hughes, and is
revealed for limited purposes only. This document is the property of Baker Hughes and is to be returned to Baker
Hughes on request and may not be reproduced, used or disclosed to persons not having a need to know consistent
with the purpose of the document, without the written consent of Baker Hughes. This document is not rented, loaned
or sold, either alone or in conjunction with equipment or product. 9/13/11 Baker Hughes Incorporated.

SC-2 Packer (Product Family H48807)

Unit No. TU 5632


September 13, 2011

Page 8 of 12

SC-2 Packer (Product Family H48807)


Dimensional Data, Sizes 66-32 - 70-40
Refer to Drawing 662-476-1TU.
Dim.

Size
66A2-32

Rev. I

A
B
C
D
E
F
G
H
X
Y

66A4-32

70A2-32

70A4-32

5.312
5.355

70B-32

70C-32

70A4-40

70B-40

5.687
5.562

5.735

5.820

6.000

6.250

5.820

70C-40

6.000

This document is and contains unpublished, copyrighted and confidential information of Baker Hughes, and is
revealed for limited purposes only. This document is the property of Baker Hughes and is to be returned to Baker
Hughes on request and may not be reproduced, used or disclosed to persons not having a need to know consistent
with the purpose of the document, without the written consent of Baker Hughes. This document is not rented, loaned
or sold, either alone or in conjunction with equipment or product. 9/13/11 Baker Hughes Incorporated.

6.190
4.000
4.062
5.800
9.72
32.16
56.57
4-1/2 LH Sq Thd
5-1/2 Sht Csg Thd

3.250
3.312
5.312
11.06
33.56
56.62

70B2-40
5.750

5.687
10.94
34.48
56.50
4 LH Sq Thd
4-1/2 Sht Csg Thd

6.250

Dimensional Data, Sizes 76-32, 76-40, and 96-47


Refer to Drawing 662-476-1TU.
Dim.

76A2-32

76A3-32

A
B
C
D
E
F
G
H
X
Y

76A4-32

76B2-32

76B4-32

76A2-40

Size
76A3-40
76A4-40

6.437
6.440

6.490

6.580
6.690
3.250
3.312
6.375
10.66
33.39
56.22
4 LH Sq Thd
4-1/2 Sht Csg Thd

76B2-40

76B4-40

96A-47

96A2-47

6.375
6.784

6.440

6.490

6.580
6.690
4.000
4.062
6.375
10.42
33.40
57.26
4-1/2 LH Sq Thd
5-1/2 Sht Csg Thd

96A4-47

96B-47

8.125
6.784

8.191

8.319

8.465
4.750
4.812
8.125
12.13
40.19
68.01
5-1/4 LH Sq Thd
6-5/8 Rd Sht Thd

8.619

Dimensional Data Drawing K00-299TUP01, Sizes 96-40 and 107-60

Dimensional Data, Sizes 96-40 and 107-60

This document is and contains unpublished, copyrighted and confidential information of Baker Hughes, and is
revealed for limited purposes only. This document is the property of Baker Hughes and is to be returned to Baker
Hughes on request and may not be reproduced, used or disclosed to persons not having a need to know consistent
with the purpose of the document, without the written consent of Baker Hughes. This document is not rented, loaned
or sold, either alone or in conjunction with equipment or product. 9/13/11 Baker Hughes Incorporated.

SC-2 Packer (Product Family H48807)

107A4-60
107A2-60

9.125

9.400
9.330

6.000

6.062

8.585

12.76

41.85

6.500 Baker LH Sq Thd


74.19

7.625 Sht Csg Thd

Page 9 of 12

Unit No. TU 5632


September 13, 2011

A
B
C
D
E
F
G
H
X
Y

8.191

Size
96A2-40 96A4-40
96B-40
8.125
8.319
8.465
8.619
4.000
4.062
8.125
12.13
40.19
68.01
4.500 Baker LH Sq Thd
5-1/2 Sht Csg Thd
96A-40
DIm.

Rev. I

Refer to Drawing K00-299TUP01.

Dimensional Data Drawing 641-493-1TU, Sizes 86-40 and 96-60

Page 10 of 12

Unit No. TU 5632


September 13, 2011

SC-2 Packer

Rev. I

This document is and contains unpublished, copyrighted and confidential information of Baker Hughes, and is
revealed for limited purposes only. This document is the property of Baker Hughes and is to be returned to Baker
Hughes on request and may not be reproduced, used or disclosed to persons not having a need to know consistent
with the purpose of the document, without the written consent of Baker Hughes. This document is not rented, loaned
or sold, either alone or in conjunction with equipment or product. 9/13/11 Baker Hughes Incorporated.

Dimensional Data, Size 86-40


Refer to Drawing 641-493-1TU.

8.598

8.680
8.522
6.000
6.062
8.175
12.23
41.17
69.66
6.500 LH Sq Thd
7-5/8 OD SH Csg Thd

96C4-60
8.452
8.313
8.219

96C-60

96C2-60
8.175

Rev. I

A
B
C
D
E
F
G
H
X
Y

96B2-60
96B-60
96A-60

Size
Dim.

86B-40
86A-40

6.750
6.935

7.060
4.000
4.067
6.060
10.44
33.81
59.43
4.500 Left-hand Square Thd,
5 1/2 OD Short Casing Thd,

Dim.
A
B
C
D
E
F
G
H
X
Y

Dimensional Data, Size 96-60


Refer to Drawing 641-493-1TU.

This document is and contains unpublished, copyrighted and confidential information of Baker Hughes, and is
revealed for limited purposes only. This document is the property of Baker Hughes and is to be returned to Baker
Hughes on request and may not be reproduced, used or disclosed to persons not having a need to know consistent
with the purpose of the document, without the written consent of Baker Hughes. This document is not rented, loaned
or sold, either alone or in conjunction with equipment or product. 9/13/11 Baker Hughes Incorporated.

SC-2 Packer

Unit No. TU 5632


September 13, 2011
Page 11 of 12

Dimensional Data Drawing 641-141TU

Page 12 of 12

Unit No. TU 5632


September 13, 2011

CK Components for SC-2 Packer (Product Family H48807)

Rev. I

Refer to Drawing 641-141TU.

4-1/2
LH Sq Thd
5.312
8 Stub Acme

96-47
96-60
107-60
67.66
69.66
71.69
5.200
6.310
6.500
5-1/4
6-1/2
6-1/2
LH Sq Thd LH Sq Thd LH Sq Thd
6.500
7.750
7.750
6 Stub Acme 6 Stub Acme 6 Stub Acme
96-40
68.69
4.500
76-40
56.70
4.430
A
B

3-1/4
LH Sq Thd
3.688
4.000
8 Stub Acme 6 Stub Acme

3.690
4
LH Sq Thd
4.500
8 Stub Acme

Size
70-40
76-32
56.00
57.67
4.310
3.690
4-1/2
4
LH Sq Thd LH Sq Thd
5.312
4.500
8 Stub Acme 8 Stub Acme
70-32
57.95
66-32
59.66

55-26
55.27
3.060
50-26
54.79
2.930
Dim.

This document is and contains unpublished, copyrighted and confidential information of Baker Hughes, and is
revealed for limited purposes only. This document is the property of Baker Hughes and is to be returned to Baker
Hughes on request and may not be reproduced, used or disclosed to persons not having a need to know consistent
with the purpose of the document, without the written consent of Baker Hughes. This document is not rented, loaned
or sold, either alone or in conjunction with equipment or product. 9/13/11 Baker Hughes Incorporated.

Dimensional Data, Sizes 50-26 - 107-60