CUMMINS INC.

Charleston, SC 29405
Marine Generator Set Installation Data
Heat exchanger/Keel cooled

C-POWER
Generator Output
Prime Rating Output (V)
Prime Rating Output Power (kWe)

Generator Set Model:


6C-CP170DM/6
Engine Configuration:
D413045MX02

416
160

440
170

Engine Data
Engine model........
Cylinders/Configuration..... ....
Displacement...........litres [in]
Aspiration
.
Exhaust type
...
Engine speed ....rpm

Curve Number:
MG-90724a
Date:
3-Jul-06

460
170

480
170

6CTA8.3-D(M)
6/Inline
8.3 [506]
Turbocharged/Aftercooled
Wet
1800

Alternator Data
Alternator model... Newage Stamford UCM274H
Protection
IP23
.
3 phase 4 wire
Connection ...
Rated Power Factor.
0.8
Temperature Rise Class
...
F
Insulation Class....
H
60
Frequency....Hz
Fuel System
Fuel consumption @ 100% Prime Power.....l/hr [gal/hr]

46.6 [12.31]

Exhaust System
Exhaust gas flow....l/sec [cfm]
Exhaust gas turbine outlet temperature....C [F]
Heat rejection to exhaust.....kW [Btu/min]
Maximum exhaust gas back pressure.mm Hg [in Hg]

545
405
125
76.0

[1154.8]
[761.0]
[7113.4]
[3.0]

Ventilation System
Combustion air flow...l/sec [cfm]
Alternator cooling air flow.. ..l/sec [cfm]
Engine casing heat rejection... ...kW [Btu/min]
Alternator heat rejection... ...kW [Btu/min]

227
617
18
11.2

[481]
[1307]
[1024]
[637]

Cooling System
Heat exchanger sea water flow (@ 10 psi pump pressure) ....l/min [gal/min]
Heat exchanger expansion tank pressure cap rating.....kPa [psi]

170 [45]
103 [15]

Main Cooler
Main coolant flow to heat exchanger...l/min [gal/min]
Main coolant flow to keel cooler (@ 5 psi external friction head) ...l/min [gal/min]
Main coolant thermostat start open temperature.. ..........................C [F]
Main coolant thermostat full open temperature............................C [F]
Heat rejection to main cooling system. ..............................kW [Btu/min]

TBD= To Be Determined

N/A = Not Applicable

208
208
82
95
160

[55]
[55]
[180]
[203]
[9105]

N.A. = Not Available

CUMMINS ENGINE COMPANY, INC


COLUMBUS, INDIANA
All Data is Subject to Change Without Notice - Consult the following Cummins intranet site for most recent data:

http://marine.cummins.com

Marine Generator Set Installation Data


Curve No.
DS :
DATE:
Emissions in accordance with ISO 8178 Cycle D2
NOx (Oxides of nitrogen)..............g/kwhr [g/hphr]
HC (Hydrocarbons)..........................g/kwhr [g/hphr]
CO (Carbon monoxide)...........................g/kwhr [g/hphr]
PM (Particulate matter)...........................g/kwhr [g/hphr]
CO2 (Carbon dioxide)..........................g/kwhr [g/hphr]

8.86
0.76
0.68
0.20
N.A.

Generator Set Dimensions


Genset Weight Dry: Heat exchanger cooled... .kg [lb]
Length....mm [in]
Width.
..mm [in]
Height.
..mm [in]
Genset Weight Dry: Keel cooled........kg [lb]
Length....mm [in]
Width.
..mm [in]
Height.
..mm [in]

1800.00
2400
1150
1245
1720.00
2400
1150
1245

MG-90724a
DS-5010
3-Jul-06

[6.61]
[0.57]
[0.51]
[0.15]

[3,968.3]
[94.5]
[45.3]
[49.0]
[3,791.9]
[94.5]
[45.3]
[49.0]

Data Sheet References


Engine Performance Curve....
D(M)-90724
Base Engine Data Sheet....
DS-5010
Alternator Data Sheet..... UCM274H Tech Data Sheet
3170654
Installation Drawings: Heat Exchanger.......
3170652
Keel Cooled......
3978352
Wiring Diagrams:
Classed generator set.....
4081998
Standard generator set. ..
3976554
Classed control panel..
Standard control panel....
3974732

Rating Conditions: Ratings are in accordance with ISO 3046 reference conditions; air pressure at 100 kPa (29.61 in Hg), air
temperature 25C (77F), and 30% relative humidity. The fuel consumption data is based on No. 2 diesel fuel weight at 0.85 kg/liter
(7.1 lb/U.S. gal).
Prime Power Rating is applicable for supplying continual electrical power at varied load, conforming to ISO 8525 guidelines. The
following are the Prime Rating parameters:
* Prime Power is available for an unlimited number of hours per year in a variable load application. Variable load should not exceed a
70% average of the Prime Power rating during any operating period of 250 hours.
* The total operating time at 100% Prime Power shall not exceed 500 hours per year.
* There is a 10% overload capability for a period of 1 hour within a 12 hour period of operation. Total operating time at 10% overload
shall not exceed 25 hours per year.
Note.
1. All data is at Prime Power rated conditions.
2. Heat rejection to coolant values are based on 50%water/50% ethylene glycol mix and do NOT include fouling factors. If sourcing
you own cooler, a service fouling factor should be applied according to the cooler manufacturers recommendation.
3. All data is subject to a +/- 3% tolerance.