HIGH EFFICIENCY

Full DC Inverter Heat Pump Modular


& Mini VRF

YORK Variable Refrigerant Flow Systems


Efficiency and comfort for your customers.

New growth opportunities for your business.


Building climate control is about comfort and efficiency delivering
just the right heating and cooling to every space using no more energy
than necessary. YORK variable refrigerant flow (VRF) technology lets
you do that for customers in innovative ways that present new growth
opportunities for your business.

2 WHY VRF?

VRF technology gives building owners, architects, consulting engineers,


and mechanical contractors an innovative solution to address the
common challenge of reducing operating costs in buildings with varied
loads and occupancy rates while delivering comfort to all areas. The
systems can offer:

Introducing YORK VRF

2-4

What is VRF?

Why Partner with


Johnson Controls?

7-9

Summary of Features
and Benefits

10-11

12 INDOOR UNITS
Overview 12-14
Ductless Units
15-20
Ducted Units
21-29

E xceptional efficiency, delivering more energy savings than


conventional HVAC systems.
A modular system that can be customized to the exact requirements
of each project, with options that include heat pump and fan coil
options.

35 OUTDOOR UNITS
Overview 35-37
380V Heat Pump
38-50

Freedom for designers to choose ducted systems with short or


long runs, or ductless systems that allow for much lower clearance
between building floors and therefore lower overall construction costs.

51 OPTIONAL PARTS
& ACCESSORIES

Impressively quiet, with controls to deliver precisely the correct


amount of heating or cooling to each zone.

Optional Parts
& Accessories

51-52

53 CONTROLLERS
Controllers 53

The information contained in this catalog is for illustration purposes only and is subject to change at the sole discretion
of Johnson Controls. Statements, figures, calculations, plans, images and representations are only examples. Johnson
Controls encourages you, as the purchaser, to analyze your HVAC requirements and to work with Johnson Controls to
determine the exact VRF System to fulfill your needs.

JOHNSON CONTROLS | YORK VRF SYSTEMS

JOHNSON CONTROLS | YORK VRF SYSTEMS

Introducing YORK VRF from Johnson Controls


YORK VRF systems are modular and controlled
solutions that include models with capability to
heat or cool different zones.
The technology brings an array of advantages over conventional
systems.
S
 ave on energy. Systems essentially eliminate duct losses. In addition,
variable-speed compressors in outdoor units provide extremely high
part-load efficiency.

Gain control flexibility


Users can deploy from three basic control options:
Indoor fan coil units come with a selection of thermostats, from simple
units with on/off, setpoint, load and speed settings, to programmable
units that enable scheduling. Wireless units are available to provide
remote control of zone space conditions.
C
 entral station controllers for larger projects provide remote control
and scheduling of the entire system from one or more control points.

K
 eep occupants comfortable. Users can set individual temperature
set points for multiple zones. Variable-speed compressors with
wide capacity and precise modulation help maintain each zones
temperature within a narrow range. Indoor units also operate quietly.

Adapters (gateways) enable control of large buildings or campuses


through building automation systems such as Metasys.

Go green. VRF technology can help users attain LEED certification
points for resource efficiency.

YORK VRF systems suit a wide range of buildings in new construction


and retrofits. Prime candidates include:

Enjoy design freedom


A variety of standard modular components let you customize and
size equipment to meet specific project requirements. Because
ductwork is generally needed for ventilation, ducts can be smaller,
reducing capital cost. Systems can be easily adapted as space is
reconfigured. Unlike conventional HVAC systems, VRF systems allow for
the addition of capacity to accommodate expansion simply by adding
modular units (capacities 8-54 HP). There is no need to remove and
replace the original unit or reconfigure ductwork.

Choose multiple applications

B
 uildings with multiple zones that have different comfort needs
such as hotels, schools, medical office buildings, commercial office
buildings and others.
H
 istorical building renovations in which ducted HVAC options are
severely limited and the basic building structure must not be disturbed.
B
 uildings in climate zones favorable for heat pump technology.

Install with ease


YORK VRF systems are designed for quick and simple installation,
since piping from the outdoor units can be connected from the front,
back, or underneath. Indoor units are small and light and easy to
transport and handle; outdoor units can be brought into a building
for installation on a rooftop via a service elevator no crane or other
heavy equipment is needed. Service is simple, too: Systems need little
maintenance beyond changing filters and cleaning coils.

JOHNSON CONTROLS | YORK VRF SYSTEMS

JOHNSON CONTROLS | YORK VRF SYSTEMS

Advanced compressor technology yields the highest efficiency


ratings, resulting in energy savings
Rated highest for energy efficiency
The YORK VRF Systems boast
efficiencies up to:
4.1 COP

YORK systems rank impressively high in the ratings that matter most for
VRF technology. The traditional measure of HVAC equipment, Coefficient
of Performance (COP), measures system efficiency at full load. While this
may be appropriate for equipment that operates in a traditional cycle (fully
on or fully off), it is not appropriate for properly sized VRF systems, which
spend the vast majority of time at part load, reaching full load only on the
hottest or coldest days. YORK VRF systems excel against truer measures
of efficiency:

How VRF works


A VRF system typically consists of one or more outdoor condensing
units from which refrigerant is piped to a series of indoor fan coil units
serving individual zones within building spaces. The system conditions
the spaces by delivering to the indoor fan coil units only the volume
of refrigerant required to meet the heating or cooling needs of each
zone (see Figure 1).
The basic types of YORK VRF systems, ranging from
4-54HP capacity:
Heat pump VRF systems are two-pipe systems

Exclusive Hitachi compressor


results in high efficiency ratings
The core technology of YORK VRF systems is the exclusive Hitachidesigned high-efficiency scroll compressor. Hitachi invented the first air
conditioning scroll compressor in 1983 and in 2008 applied a cuttingedge large-capacity scroll compressor to VRF technology. Its advantages
include a high compression ratio, excellent reliability and efficiency, and
lower compressor noise level.

Heat pump VRF systems are two-pipe systems that


enable design for ductless or ducted applications. Precise
heating or cooling is delivered to multiple zones.

Profit from quality and innovation


The YORK VRF line includes a wide selection of products and
control options. Numerous innovative features enhance performance,
energy efficiency, quiet operation and service life. Quality is built-in,
from design through manufacturing in state-of-the-art, ISO-certified
facilities.

Figure 1

JOHNSON CONTROLS | YORK VRF SYSTEMS

JOHNSON CONTROLS | YORK VRF SYSTEMS

Get expert advice at every step: select, design, specify, install


Your Johnson Controls account team supports you as no one else
can, at every step of every project. Effective training, intuitive design
and specification software, advanced logistics and delivery, and easily
accessible documentation form a powerful support package that adds
substantial value to YORK VRF systems.

Get your team up to speed fast.


Efficient performance, quality installations.

Right-size systems with intuitive selection software


The YORK VRF selection software intuitively guides you step by
step through equipment selection, so you can quickly and accurately
choose an appropriate and cost-effective equipment package for
each project.

PC-based program

Comprehensive training programs provide knowledge and skills


necessary to effectively and efficiently deploy YORK VRF
technology. Our world-class VRF training center offers a multitude of
classes with specialized modules and topics that help:

The PC-based program gives you mobility and flexibility. The software
helps you:

Salespeople submit competitive bids and close deals.

Accurately select systems using a System Sizing Analysis. The process


starts with the indoor fan coil units, so that outdoor units are optimally
sized. Proprietary algorithms help determine system size using data
input on the indoor units, load, and measurements, so your system
does not include capacity that will go unutilized.

Designers select and configure the right equipment easily


and accurately.
Installers learn the proper procedures and complete jobs
accurately, on time and on budget.
Service technicians maintain, troubleshoot and repair systems
efficiently.
The training center includes a dedicated VRF laboratory to provide
hands-on experience with the various systems, components and
controls. YORK VRF training programs help deliver peace of mind that
your staff is prepared to support your business with the knowledge to
compete in a growing industry.

Get the tools that give you an edge

JOHNSON CONTROLS | YORK VRF SYSTEMS

Design accurate final system drawings including piping and wiring


diagrams in an easy, quick, step-by-step process.

Use intuitively designed features and functionality that make the


design process easy, fast, and accurate. You can select options and
accessories without referring to additional information or performing
additional calculations.
Gain an edge by confidently designing VRF systems that are rightsized, and include the right equipment for each project.

JOHNSON CONTROLS | YORK VRF SYSTEMS

Get winning advice to make the best decisions


Consistent delivery:
Get the right equipment to the jobsite on time
Ample inventory and advanced order management and logistics
systems can help you complete installations in a timely manner.
Consistent service and predictable deliveries help you prevent delays
arising from the wait for essential components and enable you to set
a project timeline and schedule labor efficiently. Fast and accurate
parts delivery from our main distribution center is our assurance to
customers.

YORK VRF systems bring exciting new possibilities in building space


air-conditioning, enabling you to satisfy customers, win more business,
and enhance your reputation. When you work with Johnson Controls
as your partner, our experts can guide you through a thorough analysis
to select the system that best delivers exceptional energy efficiency,
increased occupant comfort, and a lower life-cycle cost. You can choose
from a wide portfolio of HVAC solutions including:
Y
 ORK VRF systems
YORK chillers
YORK rooftop units

Lets go to work together


YORK VRF systems can be configured to meet your project
requirements and deliver exceptional performance. Select heat pump
or cooling only outdoor units with DC inverter-driven compressors
offering energy savings and the ability to scale to size. Multiple
ventilation options help make sure your systems introduce the right
volume of outside air. A host of options and accessories help ensure a
custom fit for your project. And users benefit from our variety of control
technology options.

YORK VRF systems

YORK custom built-up air handlers


Metasys building automation systems
Our analysis will provide data that helps you appropriately compare all
options, so you can make the best-informed decision on every project.

YORK Chillers

Lets explore the many advantages of VRF systems together so you


can put them to work for your customers. On these pages, you can
explore detailed information on the full range of YORK VRF systems.

YORK Rooftop units

YORK Custom built-up air handlers

JOHNSON CONTROLS | YORK VRF SYSTEMS

JOHNSON CONTROLS | YORK VRF SYSTEMS

YORK VRF Systems: Summary of Features and Benefits


BENEFITS

Compact footprint

Requires less indoor space than conventional


systems

Expands options for positioning outdoor units

Modular components

Provides flexibility to customize systems to each


projects needs

Simplifies design process


Allows easy updates as space is reconfigured or expanded

Ductless systems

Ultimate in design flexibility


Reduces clearance between building floors

Reduces system costs


Ideal for historic renovations

Ducted systems

Accommodates retrofits by making use of


existing duct infrastructure
Suits unique buildings that include ducted and
ductless areas

Reduces overall construction costs

Heat pump VRF systems

Precisely heats or cools multiple zones

Provides extreme system design flexibility

Comprehensive training

Modules tailored to specific job functions

Enables effective equipment selection and specification

Installation simplicity

Outdoor unit piping can be connected from the


front, back or underneath.
Small and light indoor units are easy to handle
without heavy equipment

Reduces installation time and cost

Modules tailored to specific job functions

Enables professional, high-quality, timely installation

Consistent, reliable product


delivery

Ensures correct components are delivered to


job sites on time

Enhances installation efficiency


Allows efficient labor scheduling

Easy maintenance access

All components accessible via removal of one


panel

Speeds up time spent on maintenance, repair,


and troubleshooting

Refrigerant check

Checks to make sure system is charged with


the correct amount of refrigerant to meet
requirements.

Helps contractor and installer adjust for optimum


efficiency and performance

Controls

Comprehensive training

System

Allows design freedom

Compressor

Suitable for short or long runs; accommodates


nearly all projects

Outdoor Units

Piping flexibility: Design


systems with pipe runs up to
1,000 m

FEATURES

Indoor Units

ADVANTAGES

BUILDING OWNER

MECHANICAL CONTRACTOR /
INSTALLER

ARCHITECT / SYSTEM DESIGNER

FEATURES

10

JOHNSON CONTROLS | YORK VRF SYSTEMS

ADVANTAGES

BENEFITS

Rotational operation

In multiple-unit applications at partial load, outdoor


units operate alternately so that operating hours are
shared equally.

Optimizes efficiency
Extends service life
Increases reliability

Backup operation function

Allows one outdoor unit to be taken off-line for


maintenance while remaining units keep operating.

Avoids system downtime


Protects occupant comfort

Efficiency optimized for


part-load operation

Part Load efficiency among industrys highest for


VRF systems

Saves energy

Noise reduction preference


mode

Lets users choose from three settings


for a not to exceed sound level

Extremely quiet (sound ratings as low as 50


dBA for outdoor units; 27 dBA for indoor units)
Ideal where outdoor units are positioned on
side of building or in locations where there are
noise restrictions

DC inverter-driven scroll
compressor

Engineered to deliver the optimum efficiency


at normal load conditions

Among industrys most efficient VRF systems:

Compressor modulation
in 1 Hz increments

Smoothly delivers only the exact amount of


refrigerant needed for the load

Allows fine control for optimum comfort


Saves energy

Demand control

Users can select from a wide variety of power


settings from 100% to 60% and program not to
exceed a given power level

Limits electric demand charges


Limits equipment wear and tear
Reduces noise

Load shedding

Allows programming to turn units on/off in rotation


at 10- to 20-minute intervals

Saves energy
Limits demand charges

Double-blade fan

Longer fan blades increase airflow quantity by 25%,


resulting in higher static pressure

Reduces noise
Extends motor life

As high as 80 Pa static
pressure in ducted systems

Offers adjustable speeds to match the static pressure


requirement

Flexibility to accommodate long or short


ductwork runs

Optional motion and


radiant sensors

Sets back temperature when space is unoccupied,


increasing efficiency even further

Saves energy

H-Link II Protocol

Controls multiple indoor and outdoor units from one


control point
Adds versatility to connect various central control
options

Maximizes indoor comfort


Saves energy
Improves system management

Temperature control

Adjusts in 1 degree F/C increments


Adjustable fan speeds

Auto-adjusts for daylight saving time


Provides options to satisfy multiple projects/
buildings

H-LINK II BACnet adapter


for integration into BMS

Enables control of VRF systems by way of a building


management system (e.g. Metasys) for almost
unlimited control in a building of campus enterprise.

Optimizes comfort
Saves energy
Unified interface for all HVAC systems

JOHNSON CONTROLS | YORK VRF SYSTEMS

11

YORK VRF INDOOR UNITS

Indoor Units Overview


Choose the style and size from the wide selection of indoor units
to meet your requirements for layout and design.

Ductless Indoor unit MODEL NUMBERS

4-Way Cassette
JTKF028H0PN-0AQ1
JTKF036H0PN-0AQ1
JTKF045H0PN-0AQ1
JTKF050H0PN-0AQ1
JTKF056H0PN-0AQ1
JTKF063H0PN-0AQ1

JTKF071H0PN-0AQ1
JTKF080H0PN-0AQ1
JTKF090H0PN-0AQ1
JTKF112H0PN-0AQ1
JTKF140H0PN-0AQ1
JTKF160H0PN-0AQ1

Wall Mount

Floor Concealed

Floor Ceiling

JTHW022H0NN-0AQ1
JTHW028H0NN-0AQ1
JTHW036H0NN-0AQ1
JTHW045H0NN-0AQ1
JTHW050H0NN-0AQ1
JTHW056H0NN-0AQ1
JTHW063H0NN-0AQ1

JTFC028H0NN-0AQ1
JTFC045H0NN-0AQ1
JTFC056H0NN-0AQ1
JTFC071H0NN-0AQ1

JTFE050H0NN-0AQ1
JTFE056H0NN-0AQ1
JTFE063H0NN-0AQ1
JTFE071H0NN-0AQ1
JTFE084H0NN-0AQ1
JTFE090H0NN-0AQ1
JTFE112H0NN-0AQ1
JTFE142H0NN-0AQ1

Ducted Indoor unit MODEL NUMBERS

Ducted High Static


JTDH022H0NN-0AQ1
JTDH028H0NN-0AQ1
JTDH036H0NN-0AQ1
JTDH045H0NN-0AQ1
JTDH050H0NN-0AQ1
JTDH056H0NN-0AQ1
JTDH063H0NN-0AQ1
JTDH071H0NN-0AQ1

Indoor Units
YORK VRF indoor units operate quietly
and are easy to install, service and
maintain. A wide variety of ductless and
ducted units are available in styles and
capacities to fit multiple applications. Units
operate quietly with sound ratings as low as
27 dBA.

12

4-Way Cassette
Wall Mounted
Ducted Low Static
Ducted High Static
Ducted Slim
Floor Concealed
Floor and Ceiling
AHU-Kit

JOHNSON CONTROLS | YORK VRF SYSTEMS

JTDH080H0NN-0AQ1
JTDH090H0NN-0AQ1
JTDH112H0NN-0AQ1
JTDH140H0NN-0AQ1
JTDH160H0NN-0AQ1
JTDH224H0NM-0AQ1
JTDH280H0NM-0AQ1

Ducted Slim
JTDS022H0PN-0AQ1
JTDS028H0PN-0AQ1
JTDS036H0PN-0AQ1
JTDS045H0PN-0AQ1
JTDS050H0PN-0AQ1
JTDS056H0PN-0AQ1

Ducted Low Static


JTDL022H0NN-0AQ1
JTDL028H0NN-0AQ1
JTDL036H0NN-0AQ1
JTDL045H0NN-0AQ1
JTDL050H0NN-0AQ1
JTDL056H0NN-0AQ1
JTDL063H0NN-0AQ1
JTDL071H0NN-0AQ1

JTDL080H0NN-0AQ1
JTDL090H0NN-0AQ1
JTDL112H0NN-0AQ1
JTDL140H0NN-0AQ1
JTDL160H0NN-0AQ1
JTDL224H0NM-0AQ1
JTDL280H0NM-0AQ1

AHU-Kit
JTDS063H0PN-0AQ1
JTDS071H0PN-0AQ1
JTDN022H0PN-0AQ1
JTDN028H0PN-0AQ1
JTDN036H0PN-0AQ1
JTDN045H0PN-0AQ1

JOHNSON CONTROLS | YORK VRF SYSTEMS

JDXF-2.0A
JDXF-4.0A

JDXF-6.0A
JDXF-10.0A

13

YORK VRF INDOOR UNITS

Indoor Unit Selection

kW
2.2 2.8 3.6 4.5 5 5.6 6.3 7.1 8 9 11.2 14 16 22.4 28
4-Way
Cassette

Wall
Mount

Ducted
High Static
Ducted
Low
Static

Ducted
Slim

Floor
Concealed

4-Way Cassette Indoor Unit


Ceiling mounted 4-way cassettes measuring 33 x 33 inch (84 x
84 cm) are offered with standard decorative panels. Compact,
thin and lightweight, they are easy to install even in tight spaces.

Floor
Ceiling

HP

10

Key Features
Optional motion and radiant heat sensors for shutoff and activation in
response to room occupancy

Capacities: 2.8 to 16kW

Multiple fan speed settings

AHU-Kit

Optional fresh air kit available


Four air volume settings including Ultra Hi for higher ceilings
4-way airflow standard but can be configured for 2-way or 3-way
Integrated condensate pumps included in all units
Uniform panel sizing
Optional lift mechanism allows panel to be lowered for convenient service
access

14

JOHNSON CONTROLS | YORK VRF SYSTEMS

JOHNSON CONTROLS | YORK VRF SYSTEMS

15

YORK VRF INDOOR UNITS

4-Way Cassette Indoor Unit

4-Way Cassette Indoor Unit

Indoor Unit Type


JTKF028H0PN-0AQ1

JTKF036H0PN-0AQ1

Sound Pressure Level (High/Medium/Low)

Outer Dimension

Btu/h

19,100

21,500

24,200

5.6

kW

6.5

7.5

8.5

9.6

Nominal Heating Capacity

kcal/h

5,600

6,500

7,300

8,300

Btu/h

22,200

25,600

29,000

32,800

Sound Pressure Level (High/Medium/Low)

dB (A)

32-30-28

32-30-28

32-30-28

32-30-28

3.3

4.9

4.2

kcal/h

2,800

3,600

4,200

4,800

Btu/h

11,100

14,300

16,700

19,100

dB (A)

32-30-28

32-30-28

32-30-28

248

248

248

32-30-28
248

(9-3/4)

(9-3/4)

(9-3/4)

(9-3/4)

840

840

840

840

(33-1/16)

(33-1/16)

(33-1/16)

(33-1/16)

840

840

840

840

(33-1/16)

(33-1/16)

(33-1/16)

(33-1/16)

23

23

23

24

(51)

(51)

(51)

(53)

13/12/11

15/13.5/12

15/13.5/12

16/14/12

(cfm)

(459/424/388)

(530/477/424)

(530/477/424)

(565/494/424)

56

56

56

56

Approximate Packing Measurement

Width

mm (in.)

Depth

mm (in.)

Net Weight

kg (Ibs.)

Air Flow Rate (Hi/Me/Lo)


Motor

6.35

6.35

(1/4)

(1/4)

(1/4)

(1/4)

mm

12.7

12.7

12.7

15.88

(in.)

(1/2)

(1/2)

(1/2)

(5/8)

VP25

VP25

VP25

VP25

Condensate Drain

0.22

Approximate Packing Measurement

0.22
P-N23NAQ

0.22

0.22

P-N23NAQ

P-N23NAQ

mm (in.)
mm (in.)
mm (in.)
kg (lbs.)
m3

248

248

298

(9-3/4)

(9-3/4)

(11-3/4)

840

840

840

840

(33-1/16)

(33-1/16)

(33-1/16)

(33-1/16)

840

840

840

840

(33-1/16)

(33-1/16)

(33-1/16)

(33-1/16)

24

24

24

26

(53)

(53)

(53)

(57)

P-N23NAQ

m3/min.

16/14/12

19/17/14

20/17/15

26/23/20

(cfm)

(565/494/424)

(671/600/494)

(706/600/530)

(918/812/706)

56

56

56

56

mm

Refrigerant Piping

6.35

m3

248
(9-3/4)

R410A (Nitrogen-Charged for Corrosion-Resistance)

Indoor Fan

6.35

Liquid Line
Gas Line

Flare-Nut Connection (with Flare Nuts)

(in.)

6.35

9.53

9.53

9.53

(1/4)

(3/8)

(3/8)

(3/8)

mm

15.88

15.88

15.88

15.88

(in.)

(5/8)

(5/8)

(5/8)

(5/8)

VP25

VP25

VP25

VP25

Adaptable Panel Model

0.22

0.22

0.22

0.26

P-N23NAQ

P-N23NAQ

P-N23NAQ

P-N23NAQ

37

37

37

37

(1-7/16)

(1-7/16)

(1-7/16)

(1-7/16)

Neutral White

Color

37

37

37

37

(1-7/16)

(1-7/16)

(1-7/16)

(1-7/16)

950

950

950

950

(37-3/8)

(37-3/8)

(37-3/8)

(37-3/8)

950

950

950

950

(37-3/8)

(37-3/8)

(37-3/8)

(37-3/8)

(13)

(13)

(13)

(13)

0.08

0.08

0.08

0.08

Outer Dimension

Height

mm (in.)

Width

mm (in.)

Depth

mm (in.)

Net Weight
Approximate Packing Measurement

kg (lbs.)
m3

950

950

950

950

(37-3/8)

(37-3/8)

(37-3/8)

(37-3/8)

950

950

950

950

(37-3/8)

(37-3/8)

(37-3/8)

(37-3/8)

(13)

(13)

(13)

(13)

0.08

0.08

0.08

0.08

NOTES:
1. The nominal cooling capacity is the combined capacity of Johnson Controls standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Indoor Air Inlet Temperature:
27C DB (80F DB)

19.0C WB (66.2F WB)

Outdoor Air Inlet Temperature:
35C DB (95F DB)
Heating Operation Conditions

Indoor Air Inlet Temperature:
20C DB (68F DB)

Outdoor Air Inlet Temperature:
7C DB (45F DB)

6C WB (43F WB)
Piping Length: 7.5 Meters

Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions:
1.5 Meter Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected should be taken into consideration in the field.

NOTES:
1. The nominal cooling capacity is the combined capacity of Johnson Controls standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Indoor Air Inlet Temperature:
27C DB (80F DB)

19.0C WB (66.2F WB)
Outdoor Air Inlet Temperature:
35C DB (95F DB)
Heating Operation Conditions
Indoor Air Inlet Temperature:
20C DB (68F DB)
Outdoor Air Inlet Temperature:
7C DB (45F DB)

6C WB (43F WB)
Piping Length: 7.5 Meters

Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions:
1.5 Meter Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected should be taken into consideration in the field.

16

mm (in.)

(in.)

Neutral White

Net Weight

Outer Dimension

Height

Connections

Flare-Nut Connection (with Flare Nuts)

Color

Depth

Nominal Cooling Capacity

Refrigerant

m3/min.

Adaptable Panel Model

Width

28,700

4,300

Condensate Drain

Height

7,200

17,000

mm

Approximate Packing Measurement

6,100

3,700

R410A (Nitrogen-Charged for Corrosion-Resistance)

Gas Line

5,400

14,700

kg (Ibs.)

Liquid Line

8.4

4,800

3,100

mm (in.)

Refrigerant Piping

7.1

kcal/h

AC 1,220-240V/50Hz

12,300

Depth

Connections

6.3

9,500

mm (in.)

Air Flow Rate (Hi/Me/Lo)

5.6

2,400

Width

Motor

JTKF080H0PN-0AQ1

Btu/h

Refrigerant

Outer Dimension

5.0

JTKF071H0PN-0AQ1

kcal/h

mm (in.)

Indoor Fan

kW

Indoor Unit Power Supply


4.3

3.6

JTKF063H0PN-0AQ1

2.8

Height

Net Weight

JTKF050H0PN-0AQ1

JTKF056H0PN-0AQ1

kW

kW
Nominal Heating Capacity

JTKF045H0PN-0AQ1

4-Way Cassette Type

Model

AC 1,220-240V/50Hz

Indoor Unit Power Supply


Nominal Cooling Capacity

Indoor Unit Type

4-Way Cassette Type

Model

(continued)

JOHNSON CONTROLS | YORK VRF SYSTEMS

JOHNSON CONTROLS | YORK VRF SYSTEMS

17

YORK VRF INDOOR UNITS

4-Way Cassette Indoor Unit

(continued)

Indoor Unit Type

4-Way Cassette Type

Model

JTKF090H0PN-0AQ1

JTKF112H0PN-0AQ1

kW

9.0

11.2

14.2

16.0

kcal/h

7,700

9,600

12,200

13,800

Btu/h

30,700

38,000

48,400

54,600

kW

10.0

13.0

16.3

18.0

Nominal Heating Capacity

kcal/h

8,600

11,200

14,000

15,500

Btu/h

34,100

44,400

55,500

61,400

Sound Pressure Level (High/Medium/Low)

dB (A)

34-32-30

41-36-33

43-38-35

44-40-36

Outer Dimension

Height

mm (in.)

Width

mm (in.)

Depth

mm (in.)

Net Weight

kg (Ibs.)

298

298

298

298

(11-3/4)

(11-3/4)

(11-3/4)

(11-3/4)

840

840

840

840

(33-1/16)

(33-1/16)

(33-1/16)

(33-1/16)

840

840

840

840

(33-1/16)

(33-1/16)

(33-1/16)

(33-1/16)

26

29

29

29

(57)

(64)

(64)

(64)

R410A (Nitrogen-Charged for Corrosion-Resistance)

Refrigerant
Indoor Fan
Air Flow Rate (Hi/Me/Lo)
Motor
Connections

m3/min.

26/23/20

32/28/24

34/29/25

37/32/27

(cfm)

(918/812/706)

(1,130/989/847)

(1,201/1,024/883)

(1,307/1,130/954)

56

108

108

108

mm

Refrigerant Piping
Liquid Line
Gas Line

Approximate Packing Measurement

Flare-Nut Connection (with Flare Nuts)

(in.)

9.53

9.53

9.53

9.53

(3/8)

(3/8)

(3/8)

(3/8)

mm

15.88

15.88

15.88

15.88

(in.)

(5/8)

(5/8)

(5/8)

(5/8)

VP25

VP25

VP25

VP25

0.26

0.26

0.26

0.26

P-N23NAQ

P-N23NAQ

P-N23NAQ

P-N23NAQ

Condensate Drain
m

Adaptable Panel Model

Neutral White

Color
Height
Outer Dimension

JTKF160H0PN-0AQ1

AC 1,220-240V/50Hz

Indoor Unit Power Supply


Nominal Cooling Capacity

JTKF140H0PN-0AQ1

mm (in.)

Width

mm (in.)

Depth

mm (in.)

Net Weight
Approximate Packing Measurement

kg (lbs.)
m3

37

37

37

37

(1-7/16)

(1-7/16)

(1-7/16)

(1-7/16)

950

950

950

950

(37-3/8)

(37-3/8)

(37-3/8)

(37-3/8)

950

950

950

950

(37-3/8)

(37-3/8)

(37-3/8)

(37-3/8)

(13)

(13)

(13)

(13)

0.08

0.08

0.08

0.08

Wall Indoor Unit


Wall-mount units include
wide-angle louvers that distribute airflow comfortably. An
auto-swing function ensures
efficient air distribution and
uniform temperature throughout the conditioned space.
Refrigerant and drain piping
can be connected at the right,
left or rear of the unit for ease
of installation.

Key Features
Removable front panel for
easy cleaning

Standard condensate pump

JTHW022H0NN-0AQ1

Nominal Cooling Capacity

Nominal Heating Capacity

Sound Pressure Level


(High/Medium/Low)
Outer Dimension(H)

Outer Dimension(W)

Net Weight

2.2

2.8

3.6

kcal/h

1,900

2,400

3,100

Btu/h

7,500

9,600

12,300

kw

2.5

3.3

kcal/h

2,150

2,800

3,450

Btu/h

8,500

11,100

13,600

dB(A)

38/36/32

38/36/32

40/36/34

mm

280

280

280

(in.)

11

11

11
780

mm

780

780

(in.)

31

31

31

mm

220

220

220

(in.)

kg

10

10

10

(lbs)

22

22

22

R410A (Nitrogen-charged for Corrosion-resistance)

lndoor Fan Air Flow Rate

m3/

(Cooling/Heating)

min
w

Gas Line

30

Approximate Packing

JOHNSON CONTROLS | YORK VRF SYSTEMS

510/450/390

550/450/400

30

30

Flare-nut Connection(with Flare Nuts)


mm

6.35

6.35

6.35

(in.)

(1/4)

(1/4)

(1/4)

mm

12.7

12.7

12.7

(in.)

(1/2)

(1/2)

(1/2)

VP16

VP16

VP16

0.12

0.12

0.12

Condensate Drain

JOHNSON CONTROLS | YORK VRF SYSTEMS

510/450/390

Connections Refrigerant Piping


Liquid Line

JTHW036H0NN-0AQ1

kw

Refrigerant

Motor Power

JTHW028H0NN-0AQ1
AC1.220V-240V/50HZ

Power Supply

Measurement

18

Wall Type

Model

Outer Dimension(D)

Standard wireless controller


and built-in wireless sensor

NOTES:
1. The nominal cooling capacity is the combined capacity of Johnson Controls standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions

Indoor Air Inlet Temperature:
27C DB (80F DB)

19.0C WB (66.2F WB)

Outdoor Air Inlet Temperature:
35C DB (95F DB)
Heating Operation Conditions

Indoor Air Inlet Temperature:
20C DB (68F DB)

Outdoor Air Inlet Temperature:
7C DB (45F DB)

6C WB (43F WB)
Piping Length: 7.5 Meters

Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions:
1.5 Meter Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected should be taken into consideration in the field.

lndoor

m3

19

YORK VRF INDOOR UNITS

Ducted Low Static Indoor Unit


Features
High-efficiency DC fan motor
Multiple fan speed settings
Capacities: 2.2 to 6.3 kW

Up to 30 pa static pressure
Bottom access for easy service and troubleshooting

Wall Indoor Unit (continued)


lndoor

Wall Type

Model

Capacity

Nominal Heating
Capacity
Sound Pressure Level
(High/Medium/Low)
Outer Dimension(H)

Outer Dimension(W)

Outer Dimension(D)

Net Weight

JTHW050H0NN-0AQ1

kw

Motor Power

5.6

6.3

kcal/h

3,450

4,300

4,800

5,400

Btu/h

13,600

17,000

19,100

21,500

Gas Line

4.5

5.6

6.3

7.1

3,900

4,800

5,400

6,100

Btu/h

15,300

19,100

21,500

24,200

dB (A)

41/38/35

41/38/35

41/38/35

44/41/38

mm

280

290

290

290

(in.)

11

12

12

12

mm

780

1050

1050

1050

(in.)

31

41

41

41

mm

220

220

220

220

(in.)

kg

10

13.5

13.5

13.5

(lbs)

22

30

30

30

R410A (Nitrogen-charged for Corrosion-resistance)


600/510/450

720/620/520

720/620/520

820/720/620

40

50

50

60

Flare-nut Connection(with Flare Nuts)


mm

6.35

6.35

6.35

(in.)

(1/4)

(1/4)

(1/4)

(1/4)

mm

12.7

15.88

15.88

15.88

(in.)

(1/2)

(5/8)

(5/8)

(5/8)

VP16

VP16

VP16

VP16

0.12

0.15

0.15

0.15

m3


NOTES: 1. The nominal cooling capacity is the combined capacity of Johnson Controls standard split system, and is based on the
JIS standard B8616.

Cooling Operation Conditions
Indoor Air Inlet Temperature:
27C DB (80F DB)

19.0C WB (66.2F WB)

Outdoor Air Inlet Temperature:
35C DB (95F DB)
Heating Operation Conditions

Indoor Air Inlet Temperature:
20C DB (68F DB)

Outdoor Air Inlet Temperature:
7C DB (45F DB)

6C WB (43F WB)
Piping Length: 7.5 Meters

Piping Lift: 0 Meter

20

6.35

JTDL022H0NN-0AQ1

2. The sound pressure level is based on following conditions:


1.5 Meter Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected should be
taken into consideration in the field.

JTDL036H0NN-0AQ1

JTDL045H0NN-0AQ1

JTDL050H0NN-0AQ1

AC 1,220-240V/50Hz

Nominal Cooling Capacity

kW
kcal/h
Btu/h

2.2
1,900
7,500

2.8
2,400
9,500

3.6
3,100
12,300

4.3
3,700
14,700

5.0
4,300
17,000

Nominal Heating
Capacity

kW
kcal/h
Btu/h

2.8
2,400
9,600

3.3
2,800
11,100

4.2
3,600
14,300

4.9
4,200
16,700

5.6
4,800
19,100

dB (A)

29.5-26-24.5

29.5-26-24.5

34-32-30

34-32-30

34-32-30

Height

mm
(in.)

270
(10-5/8)

270
(10-5/8)

270
(10-5/8)

270
(10-5/8)

270
(10-5/8)

Width

mm
(in.)

650+75
(25-9/16+2-15/16)

650+75
(25-9/16+2-15/16)

650+75
(25-9/16+2-15/16)

650+75
(25-9/16+2-15/16)

650+75
(25-9/16+2-15/16)

Depth

mm
(in.)

720
(28-3/8)

720
(28-3/8)

720
(28-3/8)

720
(28-3/8)

720
(28-3/8)

kg
(Ibs.)

26
(57)

26
(57)

26
(57)

26
(57)

35
(77)

Sound Pressure Level


(High/Medium/Low)

Outer Dimension

Net Weight

Indoor Fan
Air Flow Rate
(Hi/Me/Lo)

R410A (Nitrogen-Charged for Corrosion-Resistance)


m3/min.
(cfm)

8/7/6
(283/247/212)

8/7/6
(283/247/212)

13/11/9
(459/388/212)

13/11/9
(459/388/212)

15/13/11
(530/459/358)

External Pressure

pa

30

30

30

30

30

Motor

20

20

40

40

45

Connections
Refrigerant Piping

Flare-Nut Connection (with Flare Nuts)

Liquid Line

mm
(in.)

6.35
(1/4)

6.35
(1/4)

6.35
(1/4)

6.35
(1/4)

6.35
(1/4)

Gas Line

mm
(in.)

12.7
(1/2)

12.7
(1/2)

12.7
(1/2)

12.7
(1/2)

15.88
(3/8)

VP25

VP25

VP25

VP25

VP25

0.21

0.21

0.21

0.21

0.27

Condensate Drain
Approximate
Packing Measurement

JOHNSON CONTROLS | YORK VRF SYSTEMS

JTDL028H0NN-0AQ1

Indoor Unit Power Supply

Refrigerant

m /min

Condensate Drain
Approximate Packing
Measurement

Model

kw

In-the-Ceiling Type (Low Static Pressure)

JTHW063H0NN-0AQ1

kcal/h

Connections Refrigerant Piping


Liquid Line

JTHW056H0NN-0AQ1

AC1.220V-240V/50HZ

Refrigerant
lndoor Fan Air Flow Rate
(Cooling/Heating)

Indoor Unit Type

JTHW045H0NN-0AQ1

Power Supply
Nominal Cooling

Capacities: 2.2 to 28 kW

Built-in condensate pump

m3

JOHNSON CONTROLS | YORK VRF SYSTEMS

21

YORK VRF INDOOR UNITS

Ducted Low Static Indoor Unit (continued)


Indoor Unit Type
JTDL056H0NN-0AQ1

JTDL063H0NN-0AQ1

kW

Capacity
Sound Pressure Level
(High/Medium/Low)
Height
Outer Dimension

Width
Depth

Net Weight

5.6

Air Flow Rate


(Hi/Me/Lo)
External Pressure
Motor

Packing Measurement

22

9.0

4,800

5,400

6,100

7,200

7,700

21,500

24,200

28,700

30,700

kW

6.5

7.5

8.5

9.6

10.0

kcal/h

5,600

6,500

7,300

8,300

8,600

Btu/h

22,200

25,600

29,000

32,800

34,100

dB(A)

34-32-30

35-33-31

35-33-31

40-37-33

40-37-33

mm

270

270

270

350

350

(in.)

(10-5/8)

(10-5/8)

(10-5/8)

(13-3/4)

(13-3/4)

mm

900+75

900+75

900+75

900+75

900+75

(in.)

(35-7/16+2-15/16)

(35-7/16+2-15/16)

(35-7/16+2-15/16)

(35-7/16+2-15/16)

(35-7/16+2-15/16)

mm

720

720

720

800

800

(in.)

(28-3/8)

(28-3/8)

(28-3/8)

(31-1/2)

(31-1/2)

kg

35

35

35

46

46

(Ibs.)

(77)

(77)

(77)

(101)

(101)

m3/min.

15/13/11

16/14/12

16/14/12

25/21/17

25/21/17

(cfm)

(530/459/388)

(565/494/424)

(565/494/424)

(883/741/600)

(883/741/600)

pa

30

30

30

60

60

45

45

45

100

100

JTDL140H0NN-0AQ1

AC 1,220-240V-50Hz

JTDL160H0NN-0AQ1

JTDL224H0NM-0AQ1

AC 1,220V/50Hz

JTDL280H0NM-0AQ1

AC 3,380-415V/50Hz

Nominal Cooling Capacity

kW
kcal/h
Btu/h

12.6
9,600
38,000

14.2
12,200
48,400

16.0
13,800
54,600

22.4
19,300
76,500

28.0
24,100
95,600

Nominal Heating
Capacity

kW
kcal/h
Btu/h

13.0
11,200
44,400

16.3
14,000
55,500

18.0
15,500
61,400

25.0
21,500
85,300

31.5
27,100
107,500

dB(A)

41.5-39-35

42-39-35

43-39-37

50

52

Height

mm
(in.)

350
(13-3/4)

350
(13-3/4)

350
(13-3/4)

470
(18-1/2)

470
(18-1/2)

Width

mm
(in.)

900+75
(35-7/16+2-15/16)

1,300+75
(51-3/16+2-15/16)

1,300+75
(51-3/16+2-15/16)

1,060
(41-3/4)

1,250
(49-1/4)

Depth

mm
(in.)

800
(31-1/2)

800
(31-1/2)

800
(31-1/2)

1,120
(44-1/12)

1,120
(44-1/12)

kg
(Ibs.)

46
(101)

58
(128)

58
(128)

94
(207)

106
(234)

Sound Pressure Level


(High/Medium/Low)

Outer Dimension

Net Weight

Indoor Fan
Air Flow Rate
(Hi/Me/Lo)

R410A (Nitrogen-Charged for Corrosion-Resistance)


m3/min.
(cfm)

27/23/19
(954/812/671)

37/31/25
(1,306/1,095/883)

38/35/29
(1,341/1,236/1,024)

58
(2,048)

72
(2,542)

External Pressure

pa

60

60

60

100

100

Motor

100

160

180

900

1,070

Connections
Refrigerant Piping

Flare-Nut Connection (with Flare Nuts)

Flare-Nut Connection (with Flare Nuts)

Liquid Line

mm
(in.)

9.53
(3/8)

9.53
(3/8)

9.53
(3/8)

9.53
(3/8)

9.53
(3/8)

Gas Line

mm
(in.)

15.88
(5/8)

15.88
(5/8)

15.88
(3/8)

19.05
(3/4)

22.2
(7/8)

VP25

VP25

VP25

VP25

VP25

0.38

0.52

0.52

0.90

1.06

mm

6.35

9.53

9.53

9.53

9.53

(in.)

(1/4)

(3/8)

(3/8)

(3/8)

(3/8)

mm

15.88

15.88

15.88

19.05

22.2

(in.)

(5/8)

(5/8)

(3/8)

(3/4)

(7/8)

Condensate Drain

VP25

VP25

VP25

VP25

VP25

Approximate
Packing Measurement

0.27

0.27

0.27

0.38

0.38

m3

JTDL112H0NN-0AQ1

Refrigerant
R410A (Nitrogen-Charged for Corrosion-Resistance)

Condensate Drain
Approximate

8.4

19,800

Refrigerant Piping

Gas Line

Model

JTDL090H0NN-0AQ1

Btu/h

In-the-Ceiling Type (Low Static Pressure)

Indoor Unit Power Supply

7.1

6.3

Connections

Liquid Line

JTDL080H0NN-0AQ1

kcal/h

Refrigerant
Indoor Fan

JTDL071H0NN-0AQ1
AC 1,220-240V/50Hz

Indoor Unit Power Supply

Nominal Heating

Indoor Unit Type

In-the-Ceiling Type (Low Static Pressure)

Model

Nominal Cooling Capacity

Ducted Low Static Indoor Unit (continued)

m3

NOTES:
1. The nominal cooling capacity is the combined capacity of Johnson Controls standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Indoor Air Inlet Temperature:
27C DB (80F DB)

19.0C WB (66.2F WB)

Outdoor Air Inlet Temperature:
35C DB (95F DB)
Heating Operation Conditions

Indoor Air Inlet Temperature:
20C DB (68F DB)

Outdoor Air Inlet Temperature:
7C DB (45F DB)

6C WB (43F WB)
Piping Length: 7.5 Meters

Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions:
1.5 Meter Beneath the Unit.
With Discharge Duct (2.0m) and Return Duct (1.0m).
Voltage of the power source for the indoor fan motor is 220V.
In case of the power source of 240V, the sound pressure level increases by about 1 dB.
The above data was measured in an anechoic chamber so that reflected should be taken into consideration in the field.
3. The data for external pressure indicates Standard Pressure Setting values when a filter is not used.

JOHNSON CONTROLS | YORK VRF SYSTEMS

JOHNSON CONTROLS | YORK VRF SYSTEMS

23

YORK VRF INDOOR UNITS

Ducted High Static Indoor Unit

Ducted High Static Indoor Unit (continued)

Features

Indoor Unit Type


Model

High-efficiency DC fan motor


Multiple fan speed settings

Nominal Cooling Capacity

Bottom access for easy service and troubleshooting


Capacities: 2.2 to 28 kW

Built-in condensate pump

Nominal Heating
Capacity

Indoor Unit Type

In-the-Ceiling Type (High Static Pressure)


JTDH022H0NN-0AQ1

JTDH028H0NN-0AQ1

JTDH036H0NN-0AQ1

Sound Pressure Level

JTDH045H0NN-0AQ1

JTDH050H0NN-0AQ1

(High/Medium/Low)
Height

AC 1,220-240V50Hz

Indoor Unit Power Supply

Nominal Cooling Capacity

Nominal Heating
Capacity
Sound Pressure Level
(High/Medium/Low)

Outer Dimension

Width
Depth

Net Weight

5.0

2.2

2.8

kcal/h

1,900

2,400

3,100

3,700

4,300

Btu/h

7,500

9,500

12,300

14,700

17,000

kW

2.8

3.3

4.2

4.9

5.6

kcal/h

2,400

2,800

3,600

4,200

4,800

Btu/h

9,600

11,100

14,300

16,700

19,100

dB(A)

35-33-31

35-33-31

35-33-31

35-33-31

35-33-31

mm

270

270

270

270

270

(in.)

(10-5/8)

(10-5/8)

(10-5/8)

(10-5/8)

(10-5/8)

mm

650+75

650+75

650+75

650+75

900+75

(in.)

(25-9/16+2-15/16)

(25-9/16+2-15/16)

(25-9/16+2-15/16)

(25-9/16+2-15/16)

(35-7/16+2-15/16)

mm

720

720

720

720

720

(in.)

(28-3/8)

(28-3/8)

(28-3/8)

(28-3/8)

(28-3/9)

kg

26

26

26

26

35

(Ibs.)

(57)

(57)

(57)

(57)

(77)

Outer Dimension

Width
Depth

Net Weight

Indoor Fan
Air Flow Rate
(Hi/Me/Lo)
External Pressure (Option)
Motor

m3/min.

8/7/6

8/7/6

13/11/9

13/11/9

15/13/11

(cfm)

(283/247/212)

(283/247/212)

(459/388/212)

(459/388/212)

(530/459/358)

pa

50(80)

50(80)

50(80)

50(80)

50(80)

35

35

Connections

Gas Line

Packing Measurement

75

6.35

mm

6.35

6.35

6.35

6.35

(in.)

(1/4)

(1/4)

(1/4)

(1/4)

(1/4)

mm

12.7

12.7

12.7

12.7

15.88

(in.)

(1/2)

(1/2)

(1/2)

(1/2)

(5/8)

VP25

VP25

VP25

VP25

VP25

0.21

0.21

0.21

0.21

0.27

Condensate Drain
Approximate

60

JTDH080H0NN-0AQ1

JTDH090H0NN-0AQ1

kW

5.6

6.3

7.1

8.4

9.0

4,800

5,400

6,100

7,200

7,700

Btu/h

19,100

21,500

24,200

28,700

30,700

kW

6.5

7.5

8.5

9.6

10.0

kcal/h

5,600

6,500

7,300

8,300

8,600

Btu/h

22,200

25,600

29,000

32,800

34,100

dB(A)

35-33-31

36-34-32

36-34-32

42-39-35

42-39-35

mm

270

270

270

350

350

(in.)

(10-5/8)

(10-5/8)

(10-5/8)

(13-3/4)

(13-3/4)

mm

900+75

900+75

900+75

900+75

900+75

(in.)

(35-7/16+2-15/16)

(35-7/16+2-15/16)

(35-7/16+2-15/16)

(35-7/16+2-15/16)

(35-7/16+2-15/16)

mm

720

720

720

800

800

(in.)

(28-3/8)

(28-3/8)

(28-3/8)

(31-1/2)

(31-1/2)

kg

35

35

35

46

46

(Ibs.)

(77)

(77)

(77)

(101)

(101)

R410A (Nitrogen-Charged for Corrosion-Resistance)


m3/min.

15/13/11

16/14/12

16/14/12

25/21/17

25/21/17

(cfm)

(530/459/388)

(565/494/424)

(565/494/424)

(883/741/600)

(883/741/600)

External Pressure (Option)

pa

50(80)

50(80)

50(80)

120(90)

120(90)

Motor

75

75

75

120

120

9.53

Air Flow Rate


(Hi/Me/Lo)

Connections

Flare-Nut Connection (with Flare Nuts)

Refrigerant Piping

Gas Line

mm

6.35

9.53

9.53

9.53

(in.)

(1/4)

(3/8)

(3/8)

(3/8)

(3/8)

mm

15.88

15.88

15.88

15.88

15.88

(in.)

(5/8)

(5/8)

(5/8)

(5/8)

(5/8)

VP25

VP25

VP25

VP25

VP25

Approximate
Packing Measurement

0.27

0.27

0.27

0.38

0.38

m3

Flare-Nut Connection (with Flare Nuts)

Refrigerant Piping
Liquid Line

60

JTDH071H0NN-0AQ1

kcal/h

Condensate Drain

JTDH063H0NN-0AQ1

AC 1,220-240V/50Hz

Refrigerant

Liquid Line

R410A (Nitrogen-Charged for Corrosion-Resistance)

Refrigerant

24

4.3

3.6

kW

Indoor Fan
Height

JTDH056H0NN-0AQ1

Indoor Unit Power Supply

Up to 80 pa static pressure

Model

In-the-Ceiling Type (High Static Pressure)

m3

JOHNSON CONTROLS | YORK VRF SYSTEMS

JOHNSON CONTROLS | YORK VRF SYSTEMS

25

YORK VRF INDOOR UNITS

Ducted High Static Indoor Unit (continued)


Indoor Unit Type

Ducted Slim Narrow Indoor Unit


Features

In-the-Ceiling Type (High Static Pressure)

Model

JTDH112H0NN-0AQ1

JTDH140H0NN-0AQ1

JTDH224H0NM-0AQ1

AC 1,220V/50Hz

AC 1,220-240V/50Hz

Indoor Unit Power Supply

JTDH160H0NN-0AQ1

JTDH280H0NM-0AQ1

High-efficiency DC fan motor


Multiple fan speed settings

AC 3,380-415V/50Hz

Up to 30 pa static pressure

Nominal Cooling Capacity

kW
kcal/h
Btu/h

11.2
9,600
38,000

14.2
12,200
48,400

16.0
13,800
54,600

22.4
19,300
76,500

28.0
24,100
95,600

Nominal Heating
Capacity

kW
kcal/h
Btu/h

13.0
11,200
44,400

16.3
14,000
55,500

18.0
15,500
61,400

25.0
21,500
85,300

31.5
27,000
107,000

dB (A)

43-40-36

44-41-37

45-41-37

50

52

Indoor Unit

mm
(in.)

350
(13-3/4)

350
(13-3/4)

350
(13-3/4)

470
(18-1/2)

470
(18-1/2)

Power Supply

Width

mm
(in.)

900+75
(35-7/16+2-15/16)

1,300+75
(51-3/16+2-15/16)

1,300+75
(51-3/16+2-15/16)

1,060
(41-3/4)

1,250
(49-1/4)

Depth

mm
(in.)

800
(31-1/2)

800
(31-1/2)

800
(31-1/2)

1,120
(44-1/2)

1,120
(44-1/12)

kg
(Ibs.)

46
(101)

58
(128)

58
(128)

96
(211)

108
(238)

Sound Pressure Level


(High/Medium/Low)
Height
Outer
Dimension

Net Weight

Indoor Fan
Air Flow Rate
(Hi/Me/Lo)

m3/min.
(cfm)

27/23/19
(954/812/671)

37/31/25
(1,306/1,095/883)

38/35/29
(1,341/1,236/1,024)

58
(2,048)

72
(2,542)

pa

120(90)

120(90)

120(90)

180

180

Motor

120

200

280

650

900

Connections
Refrigerant Piping

JTDN022H0PN-0AQ1

Nominal Cooling Capacity

Nominal Heating Capacity

Sound Pressure Level


(High/Medium/Low)

mm
(in.)

9.53
(3/8)

9.53
(3/8)

9.53
(3/8)

9.53
(3/8)

9.53
(3/8)

Gas Line

mm
(in.)

15.88
(5/8)

15.88
(5/8)

15.88
(5/8)

19.05
(3/4)

22.2
(7/8)

Condensate Drain
m3

Net Weight

VP25

VP25

VP25

VP25

VP25

0.38

0.52

0.52

0.90

1.06

NOTES:
1. The nominal cooling capacity is the combined capacity of Johnson Controls standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Indoor Air Inlet Temperature:
27C DB (80F DB)

19.0C WB (66.2F WB)
Outdoor Air Inlet Temperature:
35C DB (95F DB)
Heating Operation Conditions
Indoor Air Inlet Temperature:
20C DB (68F DB)

Outdoor Air Inlet Temperature:
7C DB (45F DB)

6C WB (43F WB)
Piping Length: 7.5 Meters

Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions:
1.5 Meter Beneath the Unit.
With Discharge Duct (2.0m) and Return Duct (1.0m).
Voltage of the power source for the indoor fan motor is 220V.
In case of the power source of 240V, the sound pressure level increases by about 1 dB.
The above data was measured in an anechoic chamber so that reflected should be taken into consideration in the field.
3. The data for external pressure indicates Standard Pressure Setting values when a filter is not used.

Indoor Fan Air Flow Rate


(High /Medium /Low)
Motor Power

JTDN028H0PN-0AQ1

Gas Line

2.2

2.8

kcal/h

1,900

2,400

3,100

3,700

Btu/h

7,500

9,500

12,300

14,700

Kw

2.8

3.3

4.2

4.9

kcal/h

2,400

2,800

3,600

4,200

Btu/h

9,600

11,100

14,300

16,700

dB(A)

28-25-22

28-25-22

32-30-28

32-30-28

3.6

4.3

mm

192

192

192

192

mm

700

700

700

700

mm

902

602

602

602

kg

21

21

21

21

(lbs)

46

46

48

48

R410A (Nitrogen-charged for Corrosion-resistance)


m3/min

8/7/6

8/7/6

10/8/7

10/8/7

50

50

60

60

mm

6.35

6.35

6.35

6.35

(in.)

(1/4)

(1/4)

(1/4)

(1/4)

mm

12.7

12.7

12.7

12.7

(in.)

(1/2)

(1/2)

(1/2)

(1/2)

Flare-nut Connection (with Flare Nuts)

VP25

Condensate Drain
External Pressure (Option)

Pa

10(30)

10(30)

10(30)

10(30)

Approximate Packing
Measurement

m3

0.15

0.15

0.15

0.15

NOTES:
1. The nominal cooling capacity is the combined capacity of Johnson Controls standard split system, and is based on the
JIS standard B8616.
Cooling Operation Conditions
Indoor Air Inlet Temperature:
27C DB (80F DB)

19.0C WB (66.2F WB)

Outdoor Air Inlet Temperature:
35C DB (95F DB)
Heating Operation Conditions

Indoor Air Inlet Temperature:
20C DB (68F DB)

Outdoor Air Inlet Temperature:
7C DB (45F DB)

6C WB (43F WB)
Piping Length: 7.5 Meters

Piping Lift: 0 Meter

JOHNSON CONTROLS | YORK VRF SYSTEMS

JTDN045H0PN-0AQ1

Kw

Connections Refrigerant Piping


Liquid Line

JTDN036H0PN-0AQ1

AC 1,220V~240V/50Hz

Refrigerant

Flare-Nut Connection (with Flare Nuts)

Liquid Line

26

Slim In-the Ceiling Type

Model

Outer Dimension

External Pressure (Option)

Approximate
Packing Measurement

Built-in condensate pump

R410A (Nitrogen-Charged for Corrosion-Resistance)

Refrigerant

Capacities: 2.2 to 4.5 kW

Bottom access for easy service and troubleshooting

JOHNSON CONTROLS | YORK VRF SYSTEMS

2. The sound pressure level is based on following conditions:


1.5 Meter Beneath the Unit.
With Discharge Duct (2.0m) and Return Duct (1.0m).
Voltage of the power source for the indoor fan motor is 220V.
In case of the power source of 240V, the sound pressure level increases by about 1 dB.
The above data was measured in an anechoic chamber so that reflected should be taken
into consideration in the field.
3. The data for external pressure indicates Standard Pressure Setting values when a filter
is not used.

27

YORK VRF INDOOR UNITS

Ducted Slim Indoor Unit

Ducted Slim Indoor Unit (continued)

Features

Indoor Unit Type

High-efficiency DC fan motor

Model

Multiple fan speed settings


Capacities: 2.2 to 7.1 kW

Bottom access for easy service and troubleshooting

Nominal Cooling Capacity

Built-in condensate pump

Nominal Heating Capacity


Sound Pressure Level

Indoor Unit Type


JTDS022H0PN-0AQ1

JTDS028H0PN-0AQ1

(High/Medium/Low)
Height
Outer Dimension

Width
Depth

Net Weight

JTDS036H0PN-0AQ1

Outer Dimension

3.6

2.2

2.8

kcal/h

1,900

2,400

3,100

3,700

Btu/h

7,500

9,500

12,300

14,700

kW

2.8

3.3

4.2

4.9

2,400

2,800

3,600

4,200

Refrigerant

Btu/h

9,600

11,100

14,300

16,700

Indoor Fan Air Flow Rate

dB(A)

27-24-21

27-24-21

31-29-26

31-29-26

mm

192

192

192

192

(in.)

(7-9/16)

(7-9/16)

(7-9/16)

(7-9/16)

mm

900

900

900

900

(in.)

(35-7/16)

(35-7/16)

(35-7/16)

(35-7/16)

mm

447

447

447

447

(in.)

(17-19/32)

(17-19/32)

(17-19/32)

(17-19/32)

21

21

22

22

(46)

(46)

(48)

(48)

kg (Ibs.)

8/7/6

8/7/6

10/8/7

10/8/7

(283/247/212)

(283/247/212)

(353/283/247)

(353/283/247)

External Pressure (Option)

pa

10(30)

10(30)

10(30)

10(30)

Motor

16

16

25

25

Connections

Flare-Nut Connection (with Flare Nuts)

Refrigerant Piping

Gas Line

mm

6.35

6.35

6.35

(in.)

(1/4)

(1/4)

(1/4)

(1/4)

mm

12.7

12.7

12.7

12.7

(in.)

(1/2)

(1/2)

(1/2)

(1/2)

VP25

VP25

VP25

VP25

0.15

0.15

0.15

0.15

Condensate Drain
Approximate Packing Measurement

28

JTDS056H0PN-0AQ1

m3

6.35

JOHNSON CONTROLS | YORK VRF SYSTEMS

JTDS063H0PN-0AQ1

JTDS071H0PN-0AQ1

AC 1,220-240V/50Hz
kW

5.0

5.6

6.3

7.1

kcal/h

4,300

4,800

5,400

6,100

Btu/h

17,100

19,100

21,500

24,200

kW

5.6

6.5

7.5

8.5

kcal/h

4,800

5,600

6,500

7,300

Btu/h

19,100

22,200

25,600

29,000

dB(A)

34-30-28

34-30-28

35-33-30

35-33-30

mm

192

192

192

192

(in.)

(7-9/16)

(7-9/16)

(7-9/16)

(7-9/16)

mm

1,170

1,170

1,170

1,060

(in.)

(46-1/16)

(46-1/16)

(46-1/16)

(41-3/4)

mm

447

447

447

447

(in.)

(17-19/32)

(17-19/32)

(17-19/32)

(17-19/32)

kg (Ibs.)

27

27

27

27

(59)

(59)

(59)

(59)

R410A (Nitrogen-Charged for Corrosion-Resistance)


m3/min.

14.5/12.5/10.5

14.5/12.5/10.5

16/14/12

16/14/12

(cfm)

(512/442/371)

(512/442/371)

(565/494/424)

(565/494/424)

External Pressure (Option)

pa

10(30)

10(30)

10(30)

10(30)

Motor

40

40

50

50

(Hi/Me/Lo)

Flare-Nut Connection (with Flare Nuts)

Connections Refrigerant Piping


Liquid Line
Gas Line

mm

6.35

6.35

9.53

(in.)

(1/4)

(1/4)

(3/8)

(3/8)

mm

15.88

15.88

15.88

15.88

(in.)

(5/8)

(5/8)

(5/8)

(5/8)

VP25

VP25

VP25

VP25

0.18

0.18

0.18

0.18

Condensate Drain

R410A (Nitrogen-Charged for Corrosion-Resistance)

(cfm)

Liquid Line

Net Weight

kcal/h

m3/min.

(Hi/Me/Lo)

Width
Depth

4.3

kW

Refrigerant
Indoor Fan Air Flow Rate

Height

JTDS045H0PN-0AQ1

AC 1,220-240V/50Hz

Indoor Unit Power Supply

Sound Pressure Level

(High/Medium/Low)

In-the-Ceiling Type (Low Static Pressure)

Model

Nominal Heating Capacity

JTDS050H0PN-0AQ1

Indoor Unit Power Supply

Up to 30 pa static pressure

Nominal Cooling Capacity

In-the-Ceiling Type (Low Static Pressure)

Approximate Packing Measurement

m3

9.53

NOTES:
1. The nominal cooling capacity is the combined capacity of Johnson Controls standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Indoor Air Inlet Temperature:
27C DB (80F DB)

19.0C WB (66.2F WB)

Outdoor Air Inlet Temperature:
35C DB (95F DB)
Heating Operation Conditions

Indoor Air Inlet Temperature:
20C DB (68F DB)

Outdoor Air Inlet Temperature:
7C DB (45F DB)

6C WB (43F WB)
Piping Length: 7.5 Meters

Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions:
1.5 Meter Beneath the Unit.
With Discharge Duct (2.0m) and Return Duct (1.0m).
Voltage of the power source for the indoor fan motor is 220V.
In case of the power source of 240V, the sound pressure level increases by about 1 dB.
The above data was measured in an anechoic chamber so that reflected should be taken into consideration in the field.
3. The data for external pressure indicates Standard Pressure Setting values when a filter is not used.

JOHNSON CONTROLS | YORK VRF SYSTEMS

29

YORK VRF INDOOR UNITS

Floor Concealed

Floor Ceiling

Indoor Unit Type

Floor Concealed Type

Model

JTFC028H0NN-0AQ1

JTFC045H0NN-0AQ1

Nominal Heating Capacity

Sound Pressure Level


(High/Medium/Low)
Height

Outer Dimension

Width

Depth

Net Weight

Motor

4.3

5.6

7.1

kcal/h

2,400

3,700

4,800

6,100

Btu/h

9,500

14,700

19,100

24,200

kw

3.3

4.9

6.5

8.5

kcal/h

2,800

4,200

5,600

7,300

Btu/h

11,100

16,700

22,200

29,000

dB(A)

35-32-29

38-35-31

39-36-32

42-38-34

mm

620

620

620

620

(in.)

24.41

24.41

24.41

24.41

Motor Power input

mm

900

900

1,170

1,170

(in.)

35.43

35.43

46.06

46.06

mm

202

202

202

202

(in.)

7.95

7.95

7.95

7.95

kg

25

26

31

31

(lbs)

55

57

68

68

R410A/R407C/R22 (Nitrogen-Charged for Corrosion-Resistance)


m3/min.

8/7/6

10/8/7

14.5/12.5/10.5

16/14/12

16

25

40

50

Liquid Line
Gas Line

mm

6.35

6.35

Approximate
Packing Measurement

6.35

6.35

(in.)

1/4

1/4

1/4

3/8

mm

12.7

12.7

15.88

15.88

(in.)

(1/2)

(1/2)

(5/8)

(5/8)

VP25

Condensate Drain
m3

0.19

0.19

Nominal Cooling Capacity

Nominal Heating Capacity

0.23

0.23

JOHNSON CONTROLS | YORK VRF SYSTEMS

JTFE063H0NN-0AQ1

JTFE071H0NN-0AQ1

kW

5.0

5.6

6.3

7.1

kcal/h

4,300

4,800

5,400

6,100

Btu/h

17,100

19,100

21,500

24,200

kW

5.6

6.5

7.5

8.5

kcal/h

4,800

5,600

6,500

7,300

Btu/h

19,100

22,200

25,600

29,000

DC Fan motor / three speeds

Fan motor
W

40

40

70

70

Air Flow Rate Hi/Me/Lo

m/min

13/11/9

13/11/9

16.1/14//11.3

16.1/14//11.3

Sound Pressure (Ceiling)

dB(A)

39/35/30

39/35/30

45/41/37

45/41/37

Sound Pressure (Floor)

dB(A)

43/38/35

43/38/35

48/44/40

48/44/40

Outer Dimension of Package

mm

1,110/830/340

1,110/830/340

1,110/830/340

1,110/830/340

Outer Dimension of Unit

mm

990/680/230

990/680/230

990/680/230

990/680/230

Net Weight

kg

31

31

32

32

Gross Weight

kg

38

38

39

39

R410A

Refrigerant

Flare-nut Connection (with Flare Nuts)

Liquid Line

mm

6.35

6.35

9.53

9.53

Gas Line

mm

15.88

15.88

15.88

15.88

No

Drain Pump

VP25 (Outer Diameter 32)

Condensate Drain

NOTES:
1. The nominal cooling capacity is the combined capacity of Johnson Controls standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Indoor Air Inlet Temperature:
27C DB (80F DB)

19.0C WB (66.2F WB)

Outdoor Air Inlet Temperature:
35C DB (95F DB)
Heating Operation Conditions

Indoor Air Inlet Temperature:
20C DB (68F DB)

Outdoor Air Inlet Temperature:
7C DB (45F DB)

6C WB (43F WB)
Piping Length: 7.5 Meters

Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions:
1 meter beneath the Unit
1 meter from inlet grille
The above data was measured in an anechoic chamber so that reflected should be taken into consideration in the field.

30

JTFE056H0NN-0AQ1

220-240V ~ 50HZ

Pipe Connections

Flare-Nut Connection with Flare Nuts

Refrigerant piping

JTFE050H0NN-0AQ1

Indoor Unit Power Supply

2.8

Connections

Floor Ceiling Type

Model

kw

Refrigerant
Indoor Fan Air Flow Rate (Hi/Me/Lo)

JTFC071H0NN-0AQ1

AC 1,220V/50Hz

Indoor Unit Power Supply

Nominal Cooling Capacity

JTFC056H0NN-0AQ1

Indoor Unit Type

Option

Wired Remote Controller


Fresh air intake hole

No

Fan Motor Speed-up Setting

Yes

Speed-up Setting HH1

m/min

14.2

14.2

17.8

17.8

Speed-up Setting HH2

m/min

16

16

20

20

JOHNSON CONTROLS | YORK VRF SYSTEMS

31

Floor Ceiling (continued)

AHU-KIT

Indoor Unit Type


Model

JTFE084H0NN-0AQ1

JTFE090H0NN-0AQ1

Nominal Heating Capacity

JTFE112H0NN-0AQ1

JTFE142H0NN-0AQ1

220-240V ~ 50HZ

Indoor Unit Power Supply

Nominal Cooling Capacity

AHU-KIT for Air Handling Applications

Floor Ceiling Type

kW

8.4

9.0

11.2

14.2

kcal/h

7,200

7,700

9,600

12,200

Btu/h

28,700

30,700

38,200

48,500

kW

9.6

10.0

13.0

16.3

kcal/h
Btu/h

8,300

8,600

32,800

11,200

34,100

44,400

14,000
55,600

The AHU-KIT can integrate external heat exchangers of Air Handling


Units (AHU) in a VRF system to be used for air-conditioning, which can
provide more flexible air-conditioning solutions and reduce renovation
costs.
Type

Model
Capacity(HP)
Power Source

DC Fan motor / three speeds

Fan motor
Motor Power input

70

80

130

160

Control Box

AHU CONNECTION KIT


JDXF-2.0A

JDXF-4.0A

JDXF-6.0A

2HP

4HP

6HP

220-240V~50/60Hz

Height(H)

mm

341

Width(W)

mm

291

Depth(D)

mm

127

kg

Net Weight

m/min

18.2/15.2/12.2

19.4/16.3/13.3

24.8/20.5/16.3

33/28/23

Sound Pressure (Ceiling)

dB(A)

43/39/34

45/40/36

51/46/40

50/46/42

Height(H)

mm

200

Sound Pressure (Floor)

dB(A)

46/41/37

48/43/39

54/49/43

55/50/46

Width(W)

mm

165

mm

1,400/830/340

1,400/830/340

1,400/830/340

1,690/830/340

Depth(D)

mm

62

kg

1.7

Outer Dimension of Package

mm

1,285/680/230

1,285/680/230

1,285/680/230

1,580/680/230

Net Weight

kg

39

40

41

47

Gross Weight

kg

46

47

48

56

Outer Dimension of Unit

Net Weight

Compatibility

mm

9.53

9.53

9.53

9.53

Gas Line

mm

15.88

15.88

15.88

15.88

No

Fresh air intake hole


Fan Motor Speed-up Setting
Speed-up Setting HH1

m/min

Speed-up Setting HH2

m/min

19.8
22.3

21.2
23.5

2-6HP

Single Combination

8-10HP
9.53

9.53
5

Installation for Exp. Valve

Vertical/Horizontal
Indoor/Outdoor
Electrical Expansion Valve

Outlet Air Thermistor

2.5m

Inlet Air Thermistor

2.5m

Liquid Pipe Thermistor

2.5m

Yes

Gas Pipe Thermistor

2.5m

27
29.2

36
37.4

9.53

Height Difference of the Valve Box and AHU

2.5m

Exp. Valve wire


Cooling Temperature Range DB

17~35

Heating Temperature Range DB

10~27

* Cooling capacity data based on the following indoor and outdoor temperature conditions:

Operation conditions

Piping Lift: 0 Meter

Indoor air inlet temperature

2. The sound pressure level is based on following conditions:


1 meter beneath the Unit
1 meter from inlet grille.
The above data was measured in an anechoic chamber so that reflected should be taken into consideration in the field.

Outdoor air inlet temperature

6.35

No

NOTES:
1 The nominal cooling capacity is the combined capacity of Johnson Controls standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Indoor Air Inlet Temperature:
27C DB (80F DB)

19.0C WB (66.2F WB)

Outdoor Air Inlet Temperature:
35C DB (95F DB)
Piping Length: 5.0 Meters

mm

Distance of the Valve Box and AHU

Refrigerant Flow Control


Installation

Option

Wired Remote Controller

Installation

VP25 (Outer Diameter 32)

Condensate Drain

Control/Duty Signal control

Multi Combination

Pipe Size

Liquid Line

Drain Pump

Outlet Air Temperature Control/Inlet air(room air) Temperature

Capacity Control Mode

Flare-nut Connection (with Flare Nuts)

Pipe Connections

Steel Plate+White Grey Coating

Material

R410A

Refrigerant

Steel Plate with White Grey Coating (anti-corrosion)

Casing Material

Box

10HP

5.2

Air Flow Rate Hi/Me/Lo

Expansion Valve

JDXF-10.0A
8HP

Cooling
DB

27.0 C

WB

19.0 C

DB

35.0 C

WB

DB: dry bulb; WB: wet bulb


Pipe length: 7.5m; pipe height: 0m

32

JOHNSON CONTROLS | YORK VRF SYSTEMS

JOHNSON CONTROLS | YORK VRF SYSTEMS

33

Summary Table of Outdoor Units


Cooling Only
VRF

4 to 54 HP

Capacity

64

Maximum connectable indoor unit quantity

50% to 130%

Combination capacity ratio between OD and ID


Total piping length

ft (m)

3280 (1000)

Maximum piping length between OD and ID

ft (m)

541 (165)

Maximum equivalent piping length between OD and ID

ft (m)

623 (190)

Maximum piping length between 1st branch and ID

ft (m)

295 (90)

Maximum height difference between OD and ID (when OD is higher than ID)

ft (m)

164 (50)

Maximum height difference between OD and ID (when ID is higher than OD)

ft (m)

131 (40)

Maximum height difference between ID and ID

ft (m)

98 (30)

Cooling Operation Range

F (C)

14 to 118
(-10 to 48)

Heating Operation Range

F (C)

4 to 60
(-20 to 16)

Outdoor Units
Reliable, quiet YORK VRF outdoor units are available
in capacities to fit multiple applications and operate multiple
indoor units. Heat pump units provide flexibility to design for a
variety of building spaces and ambient conditions. Units operate
quietly with sound ratings as low as 50 dBA.

34

JOHNSON CONTROLS | YORK VRF SYSTEMS

JOHNSON CONTROLS | YORK VRF SYSTEMS

35

YORK VRF OUTDOOR UNITS

Outdoor Units Overview

YORK VRF Outdoor Units

YORK VRF outdoor units provide maximum flexibility for modular design.

HP 4 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54

380V Heat Pump

380V HP MODELS
8-18 HP Systems

20-36 HP Systems

38-54 HP Systems

JTOH080VPEM-0AQ1
JTOH100VPEM-0AQ1
JTOH120VPEM-0AQ1
JTOH140VPEM-0AQ1
JTOH160VPEM-0AQ1
JTOH180VPEM-0AQ1

JTOH200VPEM-0AQ1
JTOH220VPEM-0AQ1
JTOH240VPEM-0AQ1
JTOH260VPEM-0AQ1
JTOH280VPEM-0AQ1
JTOH300VPEM-0AQ1
JTOH320VPEM-0AQ1
JTOH340VPEM-0AQ1
JTOH360VPEM-0AQ1

JTOH380VPEM-0AQ1
JTOH400VPEM-0AQ1
JTOH420VPEM-0AQ1
JTOH440VPEM-0AQ1
JTOH460VPEM-0AQ1
JTOH480VPEM-0AQ1
JTOH500VPEM-0AQ1
JTOH520VPEM-0AQ1
JTOH540VPEM-0AQ1

Heat Pump
220V Single Phase

Heat Pump
380V 3 Phase

Front Flow HP MODELS


YORK VRF Outdoor Units
Single Phase 220-240V/50Hz 220V/60Hz

3 Phase 380-415V/50Hz 380V/60Hz

4-5 HP Unit

5&6 HP Unit

JDOH040HSEN-0AQ1
JDOH050HSEN-0AQ1
JDOH060HSEN-0AQ1

JDOH050HSEM-0AQ1
JDOH060HSEM-0AQ1

YORK VRF outdoor units, in capacities from 4 to 54 HP with modular


system combinations.
Heat pump units can either heat or cool spaces. YORK VRF heat pump
units offer an extended operating temperature range: outdoor ambient
temperature as low as 14 F (-10 C) in the cooling mode and as low
as -4 F (-20 C) in the heating mode.

All outdoor units feature:


Long

refrigerant piping lengths
up to 1000m total pipe run
A
 dvanced defrost cycle operation
in the heating mode
A
 ble to operate up to 64 indoor units
on a single piping network
P
 ower-saving demand control for
reduced peak load and energy savings
A
 utomatic delivery of required
refrigerant charge
D
 iagnostics and malfunction codes
available at push of a control panel
button

36

JOHNSON CONTROLS | YORK VRF SYSTEMS

JOHNSON CONTROLS | YORK VRF SYSTEMS

37

YORK VRF OUTDOOR UNITS

Outdoor Unit 380V HP

| 8-12 HP Systems

HP

8HP

10HP

12HP

Model

JTOH080VPEM-0AQ1

JTOH100VPEM-0AQ1

JTOH120VPEM-0AQ1

Combination of Base Unit

JTOH080VPEM-0AQ1

JTOH100VPEM-0AQ1

JTOH120VPEM-0AQ1

AC 3 380-415V/50Hz

Power Supply
Nominal Cooling Capacity

kW

22.4

28

33.5

Nominal Heating Capacity

kW

25

31.5

37.5

Ivory White

Cabinet Color
dB(A)

56

57

59

mm

1,720 x 950 x 750

1,720 x 950 x 750

1,720 x 950 x 750

Net Weight

kg

224

225

227

Gross Weight

kg

237

238

240

Sound Pressure Level


Outer Dimension
Height x Width x Depth

R410A

Refrigerant

Micro-Computer Control Expansion Valve

Flow Control

Hermetic (Scroll)
Compressor Quantity
1

Multi-Pass Cross-Finned Tube

Heat Exchanger

Propeller Fan
Condenser Fan Quantity

Air Flow Rate


Main Refrigerant Piping
Liquid Line
Gas Line
Refrigerant Charge

Outdoor Unit

Packing Dimension
Height x Width x Depth

380V HP (Heat PUMP)

Approximate
Packing Measurement

Heat pump units can either heat or cool spaces. YORK VRF heat pump
units offer an extended operating temperature range: outdoor ambient
temperature as low as 14 F (-10 C) in the cooling mode and as low
as -4 F (-20 C) in the heating mode.

m3/h

9,300

10,200

10,500

mm

9.53

9.53

12.7

mm

19.05

22.2

25.4

kg

8.5

9.9

mm

1,882 x 1,018 x 828

1,882 x 1,018 x 828

1,882 x 1,018 x 828

m3

1.58

1.58

1.58

NOTES:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions
Heating Operation Conditions

Indoor Air Inlet Temperature:
27C DB (80F DB) Indoor Air Inlet Temperature:
20C DB (68F DB)

19C WB (66.2F WB) Outdoor Air Inlet Temperature: 7C DB (45F DB)

Outdoor Air Inlet Temperature:
35C DB (95F DB)

6C WB (43F WB)

Piping Length: 7.5 Meters
Piping Lift: 0 Meter

8-18 HP Systems

38

JOHNSON CONTROLS | YORK VRF SYSTEMS

2. The sound pressure is based on the following conditions:


1 Meter from the unit service cover surface, and 1.5 Meters from floor level.
The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2 dB.

The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

JOHNSON CONTROLS | YORK VRF SYSTEMS

39

Outdoor Unit 380V HP


HP

| 14-18 HP Systems
14HP

16HP

18HP

Model

JTOH140VPEM-0AQ1

JTOH160VPEM-0AQ1

JTOH180VPEM-0AQ1

Combination of Base Unit

JTOH140VPEM-0AQ1

JTOH160VPEM-0AQ1

JTOH180VPEM-0AQ1

AC 3 380-415V/50Hz

Power Supply
Nominal Cooling Capacity

kW

40

45

50

Nominal Heating Capacity

kW

45

50

56

Ivory White

Cabinet Color
dB(A)

59

59

60

mm

1,720 x 1,210 x 750

1,720 x 1,210 x 750

1,720 x 1,210 x 750

Net Weight

kg

312

315

318

Gross Weight

kg

327

330

333

Sound Pressure Level


Outer Dimension
Height x Width x Depth

R410A

Refrigerant

Micro-Computer Control Expansion Valve

Flow Control

Hermetic (Scroll)
Compressor Quantity
2

Propeller Fan

Condenser Fan
Quantity

Main Refrigerant Piping


Liquid Line
Gas Line
Refrigerant Charge
Packing Dimension
Height x Width x Depth
Approximate
Packing Measurement

Multi-Pass Cross-Finned Tube

Heat Exchanger

Air Flow Rate

m3/h

11,700

11,700

11,700

mm

12.7

12.7

15.88

mm

25.4

28.6

28.6

kg

10.5

10.5

10.5

mm

1,882 x 1,278 x 828

1,882 x 1,278 x 828

1,882 x 1,278 x 828

m3

1.98

1.98

1.98

NOTES:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions
Heating Operation Conditions
Indoor Air Inlet Temperature:
27C DB (80F DB)
Indoor Air Inlet Temperature:
0C DB (68F DB)

19C WB (66.2F WB)
Outdoor Air Inlet Temperature:
7C DB (45F DB)
Outdoor Air Inlet Temperature:
35C DB (95F DB)
6C WB (43F WB)

Piping Length: 7.5 Meters
Piping Lift: 0 Meter

Outdoor Unit

380V HP (Heat PUMP)


Heat pump units can either heat or cool spaces. YORK VRF heat pump
units offer an extended operating temperature range: outdoor ambient
temperature as low as 14 F (-10 C) in the cooling mode and as low
as -4 F (-20 C) in the heating mode.

2. The sound pressure is based on the following conditions:


1 Meter from the unit service cover surface, and 1.5 Meters from floor level.
The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2 dB.

The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

40

JOHNSON CONTROLS | YORK VRF SYSTEMS

20-36 HP Systems

JOHNSON CONTROLS | YORK VRF SYSTEMS

41

YORK VRF OUTDOOR UNITS

Outdoor Unit 380V HP


HP
Model
Combination of Base Unit

Outdoor Unit 380V HP

| 20-24 HP Systems
20HP

22HP

24HP

JTOH200VPEM-0AQ1

JTOH220VPEM-0AQ1

JTOH240VPEM-0AQ1

JTOH080VPEM-0AQ1

JTOH080VPEM-0AQ1

JTOH100VPEM-0AQ1

JTOH120VPEM-0AQ1

JTOH140VPEM-0AQ1

JTOH140VPEM-0AQ1

AC 3 380-415V/50Hz

Power Supply

| 26-30 HP Systems

HP
Model
Combination of Base Unit

26HP

28HP

30HP

JTOH260VPEM-0AQ1

JTOH280VPEM-0AQ1

JTOH300VPEM-0AQ1

JTOH120VPEM-0AQ1

JTOH140VPEM-0AQ1v

JTOH140VPEM-0AQ1

JTOH140VPEM-0AQ1

JTOH140VPEM-0AQ1

JTOH160VPEM-0AQ1

AC 3 380-415V/50Hz

Power Supply

Nominal Cooling Capacity

kW

56

61.5

69

Nominal Cooling Capacity

kW

73

80

85

Nominal Heating Capacity

kW

63

69

77.5

Nominal Heating Capacity

kW

82.5

90

95

Ivory White

Cabinet Color
dB(A)

61

61

61

mm

1,720 x (950+950) x 750

1,720 x (950+1,210) x 750

1,720 x (950+1,210) x 750

Net Weight

kg

224+227

224+312

225+312

Gross Weight

kg

237+240

237+327

238+327

Sound Pressure Level


Outer Dimension
Height x Width x Depth

Flow Control

Micro-Computer Control Expansion Valve

Compressor

Hermetic (Scroll)

Quantity

Quantity

Main Refrigerant Piping


Liquid Line
Gas Line
Refrigerant Charge

62

62

mm

1,720 x (950+1,210) x 750

1,720 x (1,210+1,210) x 750

1,720 x (1,210+1,210) x 750

Net Weight

kg

227+312

312+312

312+315

Gross Weight

kg

240+327

327+327

327+330

Outer Dimension
Height x Width x Depth

R410A
Micro-Computer Control Expansion Valve
Hermetic (Scroll)

Compressor
3

Quantity

m /h

19,800

21,000

21,900

mm

15.88

15.88

15.88

mm

28.6

28.6

28.6

kg

17.9

18.5

19

Quantity
Air Flow Rate
Main Refrigerant Piping
Liquid Line
Gas Line
Refrigerant Charge

m3/h

22,200

23,400

23,400

mm

19.05

19.05

19.05

mm

31.75

31.75

31.75

kg

20.4

21

21

NOTES:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions

Heating Operation Conditions

Indoor Air Inlet Temperature:
27C DB (80F DB)
Indoor Air Inlet Temperature:
20C DB (68F DB)

19C WB (66.2F WB)
Outdoor Air Inlet Temperature: 7C DB (45F DB)

Outdoor Air Inlet Temperature:
35C DB (95F DB)

6C WB (43F WB)

Piping Length: 7.5 Meters
Piping Lift: 0 Meter

NOTES:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions
Heating Operation Conditions

Indoor Air Inlet Temperature:
27C DB (80F DB)
Indoor Air Inlet Temperature:
20C DB (68F DB)

19C WB (66.2F WB)
Outdoor Air Inlet Temperature: 7C DB (45F DB)

Outdoor Air Inlet Temperature:
35C DB (95F DB)

6C WB (43F WB)

Piping Length: 7.5 Meters
Piping Lift: 0 Meter

2. The sound pressure is based on the following conditions:


1 Meter from the unit service cover surface, and 1.5 Meters from floor level.
The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2 dB.

The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

2. The sound pressure is based on the following conditions:


1 Meter from the unit service cover surface, and 1.5 Meters from floor level.
The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2 dB.

The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

42

JOHNSON CONTROLS | YORK VRF SYSTEMS

JOHNSON CONTROLS | YORK VRF SYSTEMS

Propeller Fan

Condenser Fan

4
Multi-Pass Cross-Finned Tube

Heat Exchanger

Propeller Fan

Condenser Fan

62

Flow Control

Multi-Pass Cross-Finned Tube

Heat Exchanger

Air Flow Rate

dB(A)

Sound Pressure Level

Refrigerant

R410A

Refrigerant

Ivory White

Cabinet Color

43

Outdoor Unit 380V HP


HP
Model
Combination of Base Unit

| 32-36 HP Systems
32HP

34HP

36HP

JTOH320VPEM-0AQ1

JTOH340VPEM-0AQ1

JTOH360VPEM-0AQ1

JTOH160VPEM-0AQ1

JTOH160VPEM-0AQ1

JTOH180VPEM-0AQ1

JTOH160VPEM-0AQ1

JTOH180VPEM-0AQ1

JTOH180VPEM-0AQ1

AC 3 380-415V/50Hz

Power Supply
Nominal Cooling Capacity

kW

90

95

100

Nominal Heating Capacity

kW

100

106

112

Ivory White

Cabinet Color
dB(A)

62

63

63

mm

1,720 x (1,210+1,210) x 750

1,720 x (1,210+1,210) x 750

1,720 x (1,210+1,210) x 750

Net Weight

kg

315+315

315+318

318+318

Gross Weight

kg

330+330

330+333

333+333

Sound Pressure Level


Outer Dimension
Height x Width x Depth

R410A

Refrigerant
Flow Control

Micro-Computer Control Expansion Valve

Compressor

Hermetic (Scroll)

Quantity

Heat Exchanger

Multi-Pass Cross-Finned Tube

Condenser Fan

Propeller Fan

Quantity
Air Flow Rate
Main Refrigerant Piping
Liquid Line
Gas Line
Refrigerant Charge

m3/h

23,400

23,400

23,400

mm

19.05

19.05

19.05

mm

31.75

31.75

38.1

kg

21

21

21

NOTES:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions
Heating Operation Conditions

Indoor Air Inlet Temperature:
27C DB (80F DB)

Indoor Air Inlet Temperature:
20C DB (68F DB)
19C WB (66.2F WB)
Outdoor Air Inlet Temperature:
7C DB (45F DB)

Outdoor Air Inlet Temperature:
35C DB (95F DB)
6C WB (43F WB)

Piping Length: 7.5 Meters
Piping Lift: 0 Meter
2. The sound pressure is based on the following conditions:
1 Meter from the unit service cover surface, and 1.5 Meters from floor level.
The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2 dB.

The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

44

JOHNSON CONTROLS | YORK VRF SYSTEMS

Outdoor Unit

380V HP (Heat PUMP)


Heat pump units can either heat or cool spaces.
YORK VRF heat pump units offer an extended
operating temperature range: outdoor ambient
temperature as low as 14 F (-10 C) in the cooling
mode and as low as -4 F (-20 C) in the heating
mode.

JOHNSON CONTROLS | YORK VRF SYSTEMS

38-54 HP Systems

45

YORK VRF OUTDOOR UNITS

Outdoor Unit 380V HP


HP
Model

Combination of Base Unit

Outdoor Unit 380V HP

| 38-42 HP Systems
38HP

40HP

42HP

JTOH380VPEM-0AQ1

JTOH400VPEM-0AQ1

JTOH420VPEM-0AQ1

JTOH120VPEM-0AQ1

JTOH120VPEM-0AQ1

JTOH120VPEM-0AQ1

JTOH120VPEM-0AQ1

JTOH120VPEM-0AQ1

JTOH120VPEM-0AQ1

JTOH140VPEM-0AQ1

JTOH160VPEM-0AQ1

JTOH180VPEM-0AQ1

Nominal Cooling Capacity

kW

109

112

118

Nominal Heating Capacity

kW

118

125

132

Sound Pressure Level


Outer Dimension
Height x Width x Depth

44HP

46HP

48HP

Model

JTOH440VPEM-0AQ1

JTOH460VPEM-0AQ1

JTOH480VPEM-0AQ1

JTOH120VPEM-0AQ1

JTOH120VPEM-0AQ1

JTOH120VPEM-0AQ1

Combination of Base Unit

JTOH140VPEM-0AQ1

JTOH160VPEM-0AQ1

JTOH180VPEM-0AQ1

JTOH180VPEM-0AQ1

JTOH180VPEM-0AQ1

JTOH180VPEM-0AQ1

AC 3 380-415V/50Hz

Nominal Cooling Capacity

kW

125

132

136

Nominal Heating Capacity

kW

140

145

150

Ivory White

Cabinet Color

Ivory White

Cabinet Color

HP

Power Supply

AC 3 380-415V/50Hz

Power Supply

| 44-48 HP Systems

dB(A)

64

64

64

mm

1,720 x (950+950+1,210) x 750

1,720 x (950+950+1,210) x 750

1,720 x (950+950+1,210) x 750

dB(A)

64

64

65

mm

1,720 x (950+1,210+1,210) x 750

1,720 x (950+1,210+1,210) x 750

1,720 x (950+1,210+1,210) x 750

Net Weight

kg

227+312+318

227+315+318

227+318+318

Gross Weight

kg

240+327+333

240+330+333

240+333+333

Sound Pressure Level


Outer Dimension
Height x Width x Depth

Net Weight

kg

227+227+312

227+227+315

227+227+318

Gross Weight

kg

240+240+327

240+240+330

240+240+333

R410A

Refrigerant

Hermetic (Scroll)
4

Micro-Computer Control Expansion Valve

Flow Control

Compressor Quantity
4

R410A

Refrigerant

Micro-Computer Control Expansion Valve

Flow Control

Hermetic (Scroll)

Compressor
Quantity

Liquid Line
Gas Line
Refrigerant Charge

m3/h

32,700

32,700

32,700

Air Flow Rate

mm

19.05

19.05

19.05

Main Refrigerant Piping

mm

38.1

38.1

38.1

Gas Line

kg

30.3

30.3

30.3

NOTES:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions
Heating Operation Conditions

Indoor Air Inlet Temperature:
27C DB (80F DB)
Indoor Air Inlet Temperature:
20C DB (68F DB)

19C WB (66.2F WB)
Outdoor Air Inlet Temperature:
7C DB (45F DB)

Outdoor Air Inlet Temperature:
35C DB (95F DB)

6C WB (43F WB)

Piping Length: 7.5 Meters

Piping Lift: 0 Meter
2. The sound pressure is based on the following conditions:
1 Meter from the unit service cover surface, and 1.5 Meters from floor level.
The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2 dB.

The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

46

Propeller Fan

Condenser Fan

Condenser Fan Quantity

Main Refrigerant Piping

Multi-Pass Cross-Finned Tube

Heat Exchanger
Propeller Fan

Air Flow Rate

Multi-Pass Cross-Finned Tube

Heat Exchanger

JOHNSON CONTROLS | YORK VRF SYSTEMS

Quantity

Liquid Line

Refrigerant Charge

m3/h

33,900

33,900

33,900

mm

19.05

19.05

19.05

mm

38.1

38.1

38.1

kg

30.9

30.9

30.9

NOTES:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions

Heating Operation Conditions

Indoor Air Inlet Temperature:
27C DB (80F DB)
Indoor Air Inlet Temperature: 20C DB (68F DB)
19.0C WB (66.2F WB)
Outdoor Air Inlet Temperature: 7C DB (45F DB)

Outdoor Air Inlet Temperature:
35C DB (95F DB)

6C WB (43F WB)

Piping Length: 7.5 Meters
Piping Lift: 0 Meter
2. The sound pressure is based on the following conditions:
1 Meter from the unit service cover surface, and 1.5 Meters from floor level.
The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2 dB.

The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

JOHNSON CONTROLS | YORK VRF SYSTEMS

47

Outdoor Unit 380V HP


HP
Model

Combination of Base Unit

| 50-54 HP Systems
50HP

52HP

54HP

JTOH500VPEM-0AQ1

JTOH520VPEM-0AQ1

JTOH540VPEM-0AQ1

JTOH140VPEM-0AQ1

JTOH160VPEM-0AQ1

JTOH180VPEM-0AQ1

JTOH180VPEM-0AQ1

JTOH180VPEM-0AQ1

JTOH180VPEM-0AQ1

JTOH180VPEM-0AQ1

JTOH180VPEM-0AQ1

JTOH180VPEM-0AQ1

AC 3380-415V/50Hz

Power Supply
Nominal Cooling Capacity

kW

140

145

150

Nominal Heating Capacity

kW

155

160

165

Ivory White

Cabinet Color
dB

65

65

65

mm

1,720 x (1,201+1,210+1,210) x 750

1,720 x (1,201+1,210+1,210) x 750

1,720 x (1,201+1,210+1,210) x 750

Net Weight

kg

312+318+318

315+318+318

318+318+318

Gross Weight

kg

327+333+333

330+330+333

333+333+333

Sound Pressure Level


Outer Dimension
Height x Width x Depth

R410A

Refrigerant

Micro-Computer Control Expansion Valve

Flow Control

Hermetic (Scroll)
Compressor Quantity

Multi-Pass Cross-Finned Tube

Heat Exchanger

Propeller Fan
Condenser Fan Quantity

Air Flow Rate


Main Refrigerant Piping
Liquid Line
Gas Line
Refrigerant Charge

m3/h

35,100

35,100

35,100

mm

19.05

19.05

19.05

mm

38.1

38.1

38.1

kg

31.5

31.5

31.5

NOTES:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions

Heating Operation Conditions

Indoor Air Inlet Temperature:
27C DB (80F DB)

Indoor Air Inlet Temperature: 20C DB (68F DB)

19.0C WB (66.2F WB)

Outdoor Air Inlet Temperature: 7C DB (45F DB)

Outdoor Air Inlet Temperature:
35C DB (95F DB)

6C WB (43F WB)

Piping Length: 7.5 Meters
Piping Lift: 0 Meter
2. The sound pressure is based on the following conditions:
1 Meter from the unit service cover surface, and 1.5 Meters from floor level.
The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2 dB.

The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

48

JOHNSON CONTROLS | YORK VRF SYSTEMS

Outdoor Unit

380V HP (Heat PUMP)


Heat pump units can either heat or cool spaces. YORK VRF heat pump
units offer an extended operating temperature range: outdoor ambient
temperature as low as 14 F (-10 C) in the cooling mode and as low
as -4 F (-20 C) in the heating mode.

4-6 HP Systems

JOHNSON CONTROLS | YORK VRF SYSTEMS

49

Outdoor Unit 220V/380V HP


Model

JDOH040HSEN-0AQ1

| 4-6 HP SYSTEMS
JDOH050HSEN-0AQ1

JDOH060HSEN-0AQ1

AC1, 220-240V/50Hz,220V/60Hz

Power Supply

AC3, 380-415V/50Hz

kW

11.2

14.0

15.5

14.0

15.5

Btu/h

38,000

47,800

52,900

47,800

52,900

kw

12.5

16.0

18.0

16.0

18.0

Btu/h

42,700

54,600

61,400

54,600

61,400

(H)

mm

1,380

1,380

1,380

1,380

1,380

(W)

mm

950

950

950

950

950

(D)

mm

370

370

370

370

370

kg

103

103

103

103

103

2.5

2.8

Nominal Cooling
Capacity

Nominal Heating
Capacity

Dimension

JDOH060HSEM-0AQ1

R410A

Refrigerant

Outer

JDOH050HSEM-0AQ1

Net Weight

Hermetic DC inver

Type of Compressor
Output Power of
Compressor

kW

2.2

2.5

2.8
Multi-Pass Cross-Finned Tube

Heat Exchanger
Condenser Fan Quantity

Air Flow Rate

m3/min

90

90

100

90

100

Motor Output

51x2

51x2

51x2

51x2

51x2

48/50

48/50

50/52

48/50

50/52

42

42

45

42

45

Cooilng/
Sound Pressure
Level dB (A)

heating
NightShift mode

Micro-Computer Control Expansion Velve

Refrigerant Flow Control

Flare-Nut Connection(With Flare Nuts)

Refrigerant Piping
Liquid Connection

mm

9.53

Gas Line

mm

15.88

Pipe Connection

Multi-kit Connection

Model of Multi-Kit

JE-102SN

NOTES:
1. The nominal cooling capacity and heating capacity are based on following conditions:
Cooling Operation Conditions

Heating Operation Conditions

Indoor Air Inlet Temperature:
27C DB (80F DB)

Indoor Air Inlet Temperature:
20C DB (68F DB)

19C WB (66.2F WB)

Outdoor Air Inlet Temperature:
7C DB (45F DB)


6C WB (43F WB)

Outdoor Air Inlet Temperature:
35C DB (95F DB)

Piping Length: 7.5 Meters

Piping Lift: 0 Meter

Optional Parts & Accessories


Selection software tool indicates
which piping kits are needed for your design

2. The sound pressure level is based on following conditions:


1.5 meters from fIoor level, and 1 meter from fhe Unit service cover surface
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field

50

JOHNSON CONTROLS | YORK VRF SYSTEMS

JOHNSON CONTROLS | YORK VRF SYSTEMS

51

First Multi-kit
Outdoor Unit HP

8 and 10

12 and 18

18 and 24

26 and 54

Multi

JE-102SNQE

JE-162SNQE

JE-242SNQE

JE-302SNQE

Piping Connection Kit (for combined system)


Outdoor Unit

JTOH200~240VPEM-0AQ1

JTOH260~360VPEM-0AQ1

JTOH380~420VPEM-0AQ1
JM-30SNQE

JM-30SNQE

JM-20SNQE

JM-30SNQE

JM-20SNQE

JM-30SNQE

Multi-kit 1
Multi-kit 2

JTOH440~540VPEM-0AQ1

Controls
First Multi-kit~Last Multi-kit

YORK VRF systems offer a wide range

Total Indoor Unit HP

Lower than 6

6 to 8.99

9 to 11.99

12 to 15.99

16 to 17.99

18 to 25.99

26 to 35.99

Gas (mm)

15.88

19.05

22.2

25.4

28.6

28.6

31.75

Liquid (mm)

9.53

9.53

9.53

12.07

15.88

19.05

Multi-kit

12.07
JE-162SNQE

JE-102SNQE

JE-242SNQE

Over 36

of control systems to suit multiple applications.

38.1
19.05
JE-302SNQE

Control Systems

CWH-01QE

Last Multi-kit~Indoor Unit


Indoor Unit

Pipe Size (mm)

Max. Liquid Pipe Length

Gas Pipe

Liquid Pipe

0.8HP~1.5HP

12.7

6.35

15

1.8HP~2.0HP

15.88

6.35*1

15

2.3HP~6.0HP

15.88

9.53

40

8HP

19.05

9.53

40

10HP

22.2

9.53

40

Notes:
1. When liquid pipe length of indoor unit (0.8~2.0HP) is more than 15m, please change the liquid pipe dimension from 6.35 into 9.53.

Remote Control Switch


Compatible with the H-LINK

T
 he CWH-01QE has a design that
matches the interior.
The new large LCD display permits
users to see the operating conditions
and settings.
The timer can be set at half-hour
intervals up to 72 hours.
All the functions can be selected by
remote control switches.

52

JOHNSON CONTROLS | YORK VRF SYSTEMS

JOHNSON CONTROLS | YORK VRF SYSTEMS

The CWH-01QE monitors the


operating conditions in the system
and an alarm is issued if a problem
occurs.
A self-diagnosis function checks for
problems on printed boards in indoor
and outdoor units.
Equipped with energy-saving
functions such as a preset
temperature range limiting function
for preventing excessive cooling/
heating and a preset temperature
automatic reset function, as well as
an operation locking mechanism and
the capability to prevent users from
forgetting to turn off the system.
(Function selection setting is
required)

CRH-01QE

Wireless
Remote Control Switch
Compatible with the H-LINK

O
 ne-touch handy operation, no wiring
work required.

Two or more units can be operated


simultaneously by remote control.
* Receiver kit is required.

53

Head Office:
YORK (MALAYSIA) SALES & SERVICE SDN BHD (168496-T)

Bangunan THK, Suite 2.1, 2nd Floor,


No.2A, Jalan 243, Section 51A,
46100 Petaling Jaya, Selangor Darul Ehsan, Malaysia
Tel. 03-7628 4100 Fax: 03-7628 4101

Branches:
Penang Branch
Tel. 04-397 0213
Fax: 04-397 2045

Kota Kinabalu Branch


Tel. 088-448 350
Fax: 088-448 352

Johor Bahru Branch


Tel. 07-354 9878
Fax: 07-354 9871

Kuching Branch
Tel. 082-553 100
Fax: 082-553 200

Authorized Dealer

Customer Care Centre: 1800 88 YORK (9675)


Website: www.york.com/my

PUBL-7988 (0416)