You are on page 1of 12

STAKEHOLDER WORKSHOP

PWTC
19th October 2011
POWER QUALITY BASELINE STUDY
FOR
PENINSULAR MALAYSIA
by
DATARAN BERLIAN SDN BHD
1

Presentation Outline

Introduction
Structure of RESMOS
Features of RESMOS
RESMOS data file

PQ Stakeholder Workshop 2011

Introduction
A compact industrial standard computer control A TURE multi-channel Data
Logging System designed to operate in a harsh environment area which works
like a paperless recorder, storing data in memory at a rate and over a length of
time you specify for Power Industries.

2003 - Dataran Berlian Sdn Bhd

Research Collaboration with..


 Professor Khalid Mohamed Nor
 B.Eng.(Lpool), M.Sc, P.Hd(UMIST), SMIEEE
 Power system expert
 Provide consultancy & supervisions on development of RESMOS
 UM Electrical Engineering
 Provide staff, test tools & facilities.
 Consultancy on international Standards Compliance to IEC 51000
series.
 UTM Electrical Engineering
 Provide staff, test tools & facilities.
2003 - Dataran Berlian Sdn Bhd

PQ Stakeholder Workshop 2011

FLOW STRUCTURE RESMOS


MASTER PORTABLE UNIT
3 PH ASE VO LTAG E

2 channels

RESMOS

IN C OM IN G CU R RE NT
FEE DER

R ESM O S

R
Y
B
N
Current
input
signal
(10E R,Y,B,N) individual channel

TW O W AY
C OM M U N IC ATIO N

Full duplex
R

8 channels
O U TGO IN G C UR R EN T
FEED ERS

ELEC TRIC AL SU BSTATIO N

R ESM OS CO M M UN IC ATOR

LOC AL AR EA N ETW OR K ( LA N )

2003 - Dataran Berlian Sdn Bhd

FEATURES

Fully PC/AT compatible and computerized system control


All weather operations
Operating Temperature up to 55C
Self-powered
Portability- Compact all-in-one design for easy transportation and handling
Simultaneous Data Capturing up to 10 individual Cables (RYBN)
Harmonic measuring capabilities including its Neutral up to 21st level for
both individual and THD
In cooperated with Surge Protection capability

2003 - Dataran Berlian Sdn Bhd

PQ Stakeholder Workshop 2011

CALIBRATION
HC 6030

CT-1700

2003 - Dataran Berlian Sdn Bhd

MS IEC 60950-1:2003 & IEC 60950-1:2001

Complied with the safety


requirements conducted
according to standard
MS IEC 60950-1:2003 and IEC
60950-1:2001.
2003 - Dataran Berlian Sdn Bhd

PQ Stakeholder Workshop 2011

IP 54
IP-International Protection
5-Full protection against
contact. Protection against
interior injurious dust
deposits
4-Protection against splashed
water from all directions

2003 - Dataran Berlian Sdn Bhd

Patented 2002

2003 - Dataran Berlian Sdn Bhd

PQ Stakeholder Workshop 2011

10

CURRENT PROBES
Range (A) Application Output to Frequency Manufacturer
input ratio
range
4 - 600
Outgoing 1mA AC/ A 48Hz-1 kHz
CHAUVIN
feeders
AC
ARNOUX
100 mA 1000
100 mA 3600

2003 - Dataran Berlian Sdn Bhd

Incoming
feeders
Incoming
feeders

1mA AC/ A
AC
1mA AC/ A
AC

30 Hz-5
kHz
30 Hz-5
kHz

CHAUVIN
ARNOUX
CHAUVIN
ARNOUX

11

P/E

Indoor

2003 - Dataran Berlian Sdn Bhd

PQ Stakeholder Workshop 2011

12

F/P

Feeder pillar
Compact
2003 - Dataran Berlian Sdn Bhd

13

H POLE

2003 - Dataran Berlian Sdn Bhd

PQ Stakeholder Workshop 2011

14

INSTALLATION

Main switch board

2003 - Dataran Berlian Sdn Bhd

15

INSTALLATION

2003 - Dataran Berlian Sdn Bhd

PQ Stakeholder Workshop 2011

16

HARMONIC FILES
-csv format database:-

1.
1.

2.

2003 - Dataran Berlian Sdn Bhd

Fundamental data
(V,I, true PF)
10 individual current harmonic
percentage (R,Y,B,N) up to 21st
level & its THD value
Voltage harmonic percentage
(RN,YN,BN) up to 21st level &
its THD for both single phase &
three phase

17

Fundamental data file

2003 - Dataran Berlian Sdn Bhd

PQ Stakeholder Workshop 2011

18

Current harmonic file

2003 - Dataran Berlian Sdn Bhd

19

Current THD file

2003 - Dataran Berlian Sdn Bhd

PQ Stakeholder Workshop 2011

20

10

Voltage harmonic

21

2003 - Dataran Berlian Sdn Bhd

Voltage THD

2003 - Dataran Berlian Sdn Bhd

PQ Stakeholder Workshop 2011

22

11

THANK YOU