TABLE OF CONTENTS
FR
RECOMMENDATIONS......................................................................................................3
Periodic checks...............................................................................................................................................................................3
APPLIANCE DESCRIPTION...............................................................................................4
NL
TECHNICAL CHARACTERISTICS.....................................................................................6
ES
STARTING UP..................................................................................................................20
Tools required for starting up................................................................................................................................................ 20
Checks before starting up....................................................................................................................................................... 20
Filling the system........................................................................................................................................................................ 20
Starting up the Boiler.................................................................................................................................................................21
INSTALLATION.................................................................................................................8
MAINTENANCE...............................................................................................................22
Tools required for maintenance............................................................................................................................................ 22
Boiler shut down for maintenance....................................................................................................................................... 22
Periodic boiler maintenance tasks....................................................................................................................................... 23
Clearance..........................................................................................................................................................................................8
PL
Hydraulic characteristics.............................................................................................................................................................6
DE
Electrical Characteristics.............................................................................................................................................................6
DHW Performance.........................................................................................................................................................................6
IT
DECLARATION OF CONFORMITY................................................................................24
Package Contents........................................................................................................................................................................10
Tools required for the installation.........................................................................................................................................10
Boiler preparation before installation : E-tech S 160 - 240...........................................................................................10
DHW connection..........................................................................................................................................................................11
RU
Heating connection....................................................................................................................................................................11
Electrical Connection.................................................................................................................................................................12
Sizing of power supply wires..................................................................................................................................................12
Electrical Connection : E-Tech S 160.....................................................................................................................................12
Electrical Connection : E-Tech S 240.....................................................................................................................................13
Electrical Connection : E-Tech S 380.....................................................................................................................................13
en
EN
RECOMMENDATIONS
INSTRUCTIONS FOR THE END USER
NOTE
This manual contains important information with respect to the installation, the starting up and the
maintenance of the appliance.
This manual must be provided to the user, who will read it carefully and keep it in a safe place.
We accept no liability should any damage result from the failure to comply with theinstructions
contained in this technical manual.
The installation must comply with the instructions contained in this manual and
with the standards and regulations applicable to heating systems.
Failure to comply with the instructions in this manual could result in personal
injury or a risk of environmental pollution.
The manufacturer declines all liability for any damage caused as a result of
incorrect installation or in the event of the use of appliances or accessories that are
not specified by the manufacturer.
The availability of certain models as well as their accessories may vary according to
markets.
The manufacturer reserves the right to change the technical characteristics and
features of its products without prior notice.
In spite of the strict quality standards that ACV applies to its appliances during
production, inspection and transport, faults may occur. Please immediately notify
your approved installer of any faults.
I n the event of small amounts of hot water repeatedly being drawn off, a stratification
effect can develop in the tank. The upper hot water layer may then reach very high
temperatures.
Water heated to wash clothes, dishes and for other uses can cause serious burns.
I n order to avoid exposure to extremely hot water that can cause serious burns, never
leave children, old people, disabled or handicapped people in the bath orshower alone.
Never allow young children to turn on the hot water or fill their own bath.
This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge,
only if they have been given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved.
Cleaning and user maintenance shall not be made by children unless they are aged from
8 years and above and supervised.
FR
NL
ES
IT
DE
General remarks
Do not store any corrosive products, paint, solvents, salts, chloride products and other
detergent products near the appliance.
PERIODIC CHECKS
heck regularly that the system water pressure is at least 1 bar when cold. If the pressure
C
drops below 0.5 bar, the built-in pressure sensor blocks the appliance until the pressure
exceeds 0.8 bar.
If it is required to top up the system to maintain the minimum recommended water
pressure, always turn the appliance off and only add small amounts of water at a time.
If a large amount of cold water is added in a hot boiler, the boiler can be damaged
definitively.
If the system needs to be refilled repeatedly with water, please contact your installer.
Regularly check that there is no water on the floor under the boiler. If there is, please call
your service engineer.
PL
RU
General remark
hecking the boiler settings can only be carried out by an ACV-trained installer or by
C
ACV's maintenance department.
en
EN
APPLIANCE DESCRIPTION
CONTROL PANEL : E-TECH S 380
FR
The maximum power can be adjusted for all models by acting on the control panel switches.
NL
Models
E-Tech S 160 single phase and three-phase
E-Tech S 240 three-phase
E-Tech S 380 three-phase
Level 1
9,6 (66%)
14,4 (50%)
14,4 (50%)
kW
kW
kW
4
6
Level 2
4,8 (33%)
14,4 (50%)
14,4 (50%)
2
7
ES
3
The maximum power can be limited for this model by acting on the terminal bridges
S8 or TB2.
Models
E-Tech S 160 single phase and three-phase
E-Tech S 240 three-phase
E-Tech S 380 three-phase
IT
DE
Min
7,2
14,4
7,2
kW
kW
kW
Max
14,4
28,8
28,8
60
85
Description
PL
1. ON/OFF switch
2. Power switch level 1
3. Power switch level 2
4. Summer/Winter switch
RU
Description
1. Thermo-manometer
7. Booster switch
8. Thermo-manometer
9. Two-stage control thermostat adjustable from 60 at 85C
Control thermostat
1 = 25C
5. ON/OFF switch
2 = 40C
3 = 55C
4 = 70C
8. Summer/Winter switch
5 = 85C
en
10
11
EN
APPLIANCE DESCRIPTION
E-Tech S 160 - 240
E-Tech S 380
1.
1.
2.
Electrical support
2.
3.
Control panel
3.
4.
4.
Control panel
5.
5.
6.
Thermal insulation
6.
7.
Dip tube
7.
Electrical support
8.
8.
9.
Primary circuit
9.
Drain valve
1
2
10
11
10
11
ES
12
IT
13
14
13
NL
12
FR
14
DE
15
6
PL
15
6
16
7
7
17
18
19
16
RU
17
18
19
en
EN
TECHNICAL CHARACTERISTICS
ELECTRICAL CHARACTERISTICS
DHW PERFORMANCE
E-TECH S
FR
160
Main Characteristics
NL
380
Operating conditions at 80 C
160
240
380
Tri
Mono
Tri
Tri
Constant flow at
40 C [T = 30 K]
L/h
413
827
827
kW
14,4
14,4
28,8
28,8
Peak flow at
40 C [T = 30 K]
L/10
356
545
875
min
kW
7,2
7,2
14,4
7,2
Peak flow at
40 C [T = 30 K]
L/60
700
1234
1564
21
63
42
42
Rated voltage
3 x 400 + N
2 x 230
3 x 400 + N
3 x 400 + N
minutes
36
41
67
Rated frequency
Hz
50
50
50
50
minutes
16
12
12
Ohm
22
22
22
22
kW
2 x 2,4
2 x 2,4
2 x 2,4
2 x 2,4
IT
240
E-TECH S
max
Power
ES
DE
MAXIMUM OPERATING CONDITIONS
Maximum Service Pressure
- Primary circuit : ............................................................................................................................................ 3 bar
PL
HYDRAULIC CHARACTERISTICS
E-TECH S
RU
Main Characteristics
160
240
380
Capacity (primary)
68
86
131
- Max 6 bar, without a pressure reducing valve being required (to avoid discharge of the safety pressure valve)
Capacity (DHW)
99
164
263
Total capacity
167
250
394
12
12
2X8
Heating connection
1 [F]
1 [F]
1 [F]
DHW connection
3/4 [M]
3/4 [M]
11/2 [M]
Auxiliary connection
3/4 [F]
3/4 [F]
11/2 [M]
en
EN
TECHNICAL CHARACTERISTICS
RECOMMENDATIONS FOR THE PREVENTION OF CORROSION AND
SCALING IN HEATING SYSTEMS
How oxygen and carbonates can affect the heating system
Oxygen and dissolved gasses in the water of the primary circuit contribute to the
oxidation and the corrosion of the system components that are made of ordinary steel
(radiators, ...). The resulting sludge is then deposited in the boiler.
The combination of carbonates and carbon dioxide in the water results in the formation of scale
on the hot surfaces of the installation.
These deposits on the heating element thermally insulate the surface of the which may cause
damage elements.
Sources of oxygen and carbonates in the heating circuit
The primary circuit is a closed circuit; the water it contains is therefore isolated from the mains
water. When maintaining the system or filling up the circuit, water renewal results in the addition
of oxygen and carbonates in the primary circuit. The larger the water volume in the system, the
larger the addition.
Hydraulic components without an oxygen barrier (PE pipes and connections) admit oxygen into
the system.
fH
dH
mmolCa(HCO3)2 / l
Very soft
0-7
0 - 3.9
0 - 0.7
Soft
7 - 15
3.9 - 8.4
0.7 - 1.5
Fairly hard
15 - 25
8.4 - 14
1.5 - 2.5
Hard
25 - 42
14 - 23.5
2.5 - 4.2
> 42
> 23.5
> 4.2
Conductivity
NL
ES
Prevention Principles
1.
Water hardness
Very hard
5.
FR
IT
Chlorides
Iron
Copper
DE
PL
RU
en
EN
INSTALLATION
SAFETY INSTRUCTIONS FOR THE INSTALLATION
General remarks
FR
NL
ES
IT
The boiler must be installed in a dry and protected area, with an ambient
temperature comprised between 0 and 45C.
Install the appliance to ensure easy access at all times.
To avoid any risk of corrosion, connect the stainless steel DHW production tank
directly to the earth.
Make sure that the mains water used to fill the boiler has a minimum pressure of
1.2 bar.
Make sure to install a pressure reducing valve set at 4.5 bar if the mains supply
pressure is in excess of 6 bar.
The DHW circuit must be fitted with an approved safety group, comprised of a 7
bar safety valve, a check valve and a shut-off valve.
CLEARANCE
The boiler room must be large enough to allow proper access to the boiler. The following minimum
distances around the boiler are required :
At the front
500 mm
Above
300 mm
150 mm
This boilers can be connected to the heating circuit in any one of three directions.
DE
PL
RU
en
EN
INSTALLATION
DIMENSIONS : E-TECH S 160 - 240
360
220
220
590
260
NL
220
220
295
295
135
250
250
ES
280
1
3/4
1/2
1/2
155
1
3/4
1/2
1/2
115
280
Kg
240
160
250
E-TECH S
730
FR
295
IT
270
720
100
320
100
810
DE
2005
2010
2005
1
11/2
1/2
1/2
230
360
400
Kg
400
RU
380
400
E-TECH S
2005
2140
PL
360
360
en
EN
INSTALLATION
PACKAGE CONTENTS
FR
At product reception and after removal of packaging, check the package contents and that
the appliance is free of damages.
NL
1. Electrical boiler
2. Check valve *
3. Safety valve *
4. Drain valve *
ES
DE
PL
The drain valve (7) and the safety valve (5) must be connected to the sewer.
I f the expansion vessel volume is not sufficient for your needs, it is possible to install an
additional expansion vessel.
RU
2x
en
10
EN
INSTALLATION
DHW CONNECTION
OPTIONAL ACCESSORIES
Description
General remark
The hot water output may reach temperatures in excess of 60C, which can cause
scalding! It is therefore necessary to install a thermostatic mixing valve after the
appliance.
The installation must be fitted with an approved safety group, comprised of a 7 bar
safety valve, a check valve and a shut-off valve.
Flush the system before connecting the domestic hot water circuit. Refer to the
installation instructions.
Make sure to install a pressure reducing valve set at 4.5 bar if the mains supply
pressure is in excess of 6 bar.
Typical installation
Description
1. Isolating valve
2. Pressure reducing valve
3. Check valve
4. DHW expansion vessel
5. Safety valve
6. Drain valve
7. Draw-off tap
8. Grounding
9. Thermostatic mixing valve
3
4
9
1
Code
557A1500
55211400
55212000
55301300
55301400
55301500
55301600
FR
NL
ES
IT
HEATING CONNECTION
Typical connection - high temperature
DE
Description
1. Isolating valve
2. Heating pump
3. Filling valve
4. Check valve
5. Safety valve
6. Expansion vessel
7. Drain valve
PL
1
5
6
7
RU
3
4
Cold water
Hot water
Cold water
Hot water
en
11
EN
INSTALLATION
ELECTRICAL CONNECTION
FR
NL
ES
The wiring connections must be carried out by a competent person, in accordance with
the current IEE Wiring Regulations.
box fitted with a magneto-thermal circuit breaker must be fitted on the outside of
A
the boiler to protect the boiler and allow the power supply to be switched off during
servicing or other work on the boiler.
o avoid any risk of electrocution, the electrical circuit must be fitted with a differential
T
circuit breaker.
E-Tech S 160
PL
RU
1-2 :
3-4 :
5-6 :
7-8 :
10-11 :
12-13 :
14-15-16 :
17-18 :
IT
DE
Nominal section
(mm)
1.5
16
2.5
25
32
40
10
63
16
80
10 11 12 13 14 15 16 17 18 19 20 21 22
E-Tech S 160
Three-phase
TB1
E-Tech S 160
Mono Phase
N L3 L2 L1
400 V ~ 50 Hz
POWER
en
12
TB2
TB1
PE N
230 V ~ 50 Hz
POWER
EN
INSTALLATION
ELECTRICAL CONNECTION : E-TECH S 240
E-Tech S 240
E-Tech S 380
1-2 :
3-4 :
5-6 :
7-8 :
9-10 :
11-12 :
13-14 :
15-16 :
1
1
10 11 12 13 14 15 16 17 18 19 20 21 22
FR
TB2
3
4
5
6
7
NL
ES
1-2 :
3-4 :
5-6 :
7-8 :
10-11 :
12-13 :
14-15-16 :
17-18 :
19-20 :
10
IT
11
12
13
14
15
DE
16
TB2
CONNECTING THE POWER SUPPLY
E-Tech S 380 Three-phase : the power circuit must be connected using three phases (3 x 400 V ) +
neutral.
PL
E-Tech S 240
Three-phase
L2
L3
N
RU
E-Tech S 380
Three-phase
L1
400 V ~ 50 Hz
POWER
L1
400 V ~ 50 Hz
POWER
L2
L3
TB1
N
TB1
en
13
EN
INSTALLATION
POWER SUPPLY WIRING DIAGRAM : E-TECH S 160
B
FR
Or
Bk
NL
Or
Bk
Or
Bk
DE
K4
B
B
Or
Or
Or
K3
Or
B
B
B
B
Bk
Bk
Bk
Bk
B
B
K2
Bk
Or
IT
K1
ES
S8
B
Bk
E-Tech S 160
TB1
PL
L1
L2
L3
14,4 kW
12 kW
9,6 kW
7,2 kW
PE
S8
Three
Phase
TB2
3 4 5
L1 L2 L3
17 18
9,6 kW
3 4 5
L1 L2 L3
17 18
17 18
12 kW
3 4 5
L1 L2 L3
17 18
17 18
14,4 kW
3 4 5
L1 L2 L3
17 18
17 18
E-Tech S 160
17 18
TB2
RU
7,2 kW
B : Blue
3 4 5
L1 L1 L1
17 18
17 18
en
14
3 4 5
L1 L1 L1
17 18
TB2
R : Red
17 18
3 4 5
L1 L1 L1
17 18
K4 : Safety switch
17 18
Or : Orange
3 4 5
L1 L1 L1
17 18
Bk : Black
S8
17 18
Mono
Phase
EN
INSTALLATION
Br
PS
P
Bk
Bk
Bk
R
R
NL
1
Bk
FR
CB : Circuit breaker
Bk
S2
Bk
Bk
10
ES
Bk
T1 : Timer
11
IT
S3
K4 : Safety switch
11
Or
T1
12
A2
1.1
13
S6
Or
1.2
2.2
S5
1.2
Bk
18
Or
L1
1-1
1-1
6
B
9
B
K2
B
K3
B
K1
B
DS1
PE
8
B
B
B
Br
Br
15
16
RU
Br : Brown
K4
Pk
CB
B : Blue
Bk : Black
Br
17
Br
14
2
PL
2.2
1.1
DE
1.2
2.1
Br
1.1
S7
1
A1
2.2
3-4 : Neutral
1.1
2.2
Pk
12
Bk
1.2
S1
P1
Or
S4
1-2 : Phase
P2
21
22
G : Grey
Or : Orange
Pk : Pink
R : Red
V : Violet
W : White
Y : Yellow
en
15
EN
INSTALLATION
POWER SUPPLY WIRING DIAGRAM : E-TECH S 240
B
FR
Or
Bk
NL
Bk
Bk
Bk
B
B
Or
R
R
K4
Or
Bk
B
B
Bk
R
R
Or
Bk
Bk
K3
Or
Or
B
B
K2
Or
Bk
Bk
Or
K1
Or
ES
Bk
Bk
Or
Or
K5
DE
Bk
Bk
IT
S8
B
Bk
PL
TB1
7
L1
L2
L3
PE
TB2
RU
E-Tech S 240
28,8 kW
24 kW
21,6 kW
14,4 kW
S8
5
L3
3
L2
5
L3
3
L2
5
L3
17 18
17 18
17 18
17 18
17 18
19 20
19 20
19 20
19 20
19 20
19 20
R : Red
3
L2
17 18
19 20
K5 : Safety switch
TB2
5
L3
17 18
Or : Orange
19 20
3
L2
17 18
B : Blue
19 20
Bk : Black
5
L3
17 18
19 20
3
L2
Three
Phase
17 18
en
16
26,4 kW
EN
INSTALLATION
Br
PS
P
Bk
Bk
Bk
10
7
Bk
Y
T1 : Timer
S6 : Power switch level 2 + lamp
K2 : Power relay 1 - level 2
11
Y
K5 : Safety switch
11
Or
T1
S7
12
A2
W
R
1.1
13
S6
Or
1.2
2.2
S5
1.2
Pk
Or
L1
1-1
1-1
6
B
9
B
8
B
B
B
15
B
16
K4
B
K2
B
K3
B
K1
B
DS1
PE
B : Blue
Bk : Black
B
B
K5
20
21
22
Br : Brown
G : Grey
Or : Orange
Pk : Pink
Br
Br
RU
Bk
18
Pk
CB
19
Br
17
Br
14
2
PL
2.2
1.1
DE
3-4 : Neutral
1.2
1
A1
2.2
1-2 : Phase
1.1
2.2
Pk
12
2.1
Br
1.1
P1
Bk
P2
Or
S4
1.2
IT
S3
S1
ES
NL
1
Bk
FR
CB : Circuit breaker
Bk
S2
Bk
Bk
R : Red
V : Violet
W : White
Y : Yellow
en
17
EN
INSTALLATION
POWER SUPPLY WIRING DIAGRAM : E-TECH S 380
B
FR
Or
Bk
B
B
Bk
R
R
Bk
Bk
Bk
K4
Or
Or
B
B
Or
Bk
Bk
Or
Or
R
R
Bk
Bk
K3
L2
L3
Or
Bk
Or
L1
K2
PE
Bk
Bk
TB1
Or
B
B
IT
Or
K1
ES
Or
Bk
Or
K6
NL
TB2
DE
PL
TB1 : Terminal of power supply
TB2 : Terminal of control circuit
K1 : Power relay 1 - level 1
RU
E-Tech S 380
K6 : Safety switch
B : Blue
Bk : Black
Or : Orange
R : Red
28,8 kW
9
Three
Phase
7,2 kW
9
10
10
10
12
12
12
12
11
13
13
14
14
15
15
16
16
en
18
14 kW
10
11
TB2
21,6 kW
11
13
14
15
16
11
13
14
15
16
EN
INSTALLATION
CONTROL WIRING DIAGRAM : E-TECH S 380
CB : Circuit breaker
S1 : ON/OFF switch + lamp
S2 : Manual reset safety thermostat [103C max.]
Br
Br
R
S2
PS
1
Bk
Or
Bk
Or
4
V
PB : Booster switch
S3
1
W
32
22
Bk
Bk
Bk
14
Pk
18
12
S5
Bk
Y1
K6
B
B : Blue
Bk : Black
2
Bk
B
A2
Pk
Br
Bk
A1
K5
K4
B
DS3
Bk
Bk
DS2
Br
16
K2
B
Bk
15
14
K3
B
K1
DS1
PE
B
12
Or
13
Or
11
Br
10
Pk
CB
RU
S7
1.2
Br
2.2
1.1
Br
Or
2.2
1.1
PL
Or
24
2.1
1
Br
11
Bk
21
16
S8
1.2
31
2.2
T1
1.1
2.2
PB
15
Bk
Br
1
W
11
2
R
12
1.2
L1
Bk
6
P
S6
34
Br
P1
DE
B : Heating pump
K6 : Safety switch
P2
S4
Br
IT
1.1
ES
S1
NL
Or
Br
Or
1.2
FR
Br : Brown
G : Grey
Or : Orange
Pk : Pink
R : Red
V : Violet
W : White
en
19
EN
STARTING UP
SAFETY INSTRUCTIONS FOR STARTING UP
FR
NL
The components inside the control panel may only be accessed by an approved
installer.
Set the water temperature in accordance with usage and local plumbing codes.
1.
2.
3.
1
1
IT
Cold water
DE
Hot water
PL
RU
2.
3.
4.
5.
1
2
en
20
However, the temperature of the domestic hot water at the drawing off point must
STARTINGcomply
UP with local regulations. (E.g. in Belgium, the maximum DHW water temperature
EN
FR
NL
ES
Set-up conditions
IT
Procedure
DE
1.
).
2.
If a room thermostat is installed, possibly increase the temperature set-point to generate a demand.
If the boiler heating pump does not work, the boiler can be damaged and its life reduced.
3.
Set the central heating and domestic hot water temperatures to the required values using the
control panel.
4.
After 5 minutes of operation, bleed the heating circuit until all air is evacuated and restore a 1.5
bar pressure.
5.
Bleed the central heating circuit once again and top it up with water to get the required pressure,
if necessary.
6.
Make sure that the central heating system is properly balanced and, if needed, adjust the valves to
prevent certain circuits or radiators from getting a flow rate that is far above or below the set rate.
PL
RU
Follow-up tasks
7.
8.
en
21
EN
MAINTENANCE
SAFETY INSTRUCTIONS FOR THE BOILER MAINTENANCE
Essential recommendation for the electrical safety
FR
NL
Isolate the external power supply of the appliance before performing any
operation, unless it is required to take measurements or perform system setup.
ES
Water flowing out of the drain valve may be extremely hot and could cause severe
scalding.
IT
DE
It is recommended to have the boiler serviced at least once a year. More frequent
servicing may be required depending on boiler use. Please consult your installer
for advice.
The boiler maintenance will be carried out by a qualified engineer, and the
defective parts may only be replaced by genuine factory parts.
Make sure to replace the gaskets of the removed items before reinstalling them.
RU
en
22
EN
MAINTENANCE
PERIODIC BOILER MAINTENANCE TASKS
Tasks
1.
2.
Periodic inspection
1 year
End-user
Professional
4.
5.
Inspect the wiring and the heating elements looking for any
sign of overheating.
6.
7.
1.
2.
3.
4.
5.
1
IT
1
DE
Cold water
Hot water
1.
2.
3.
ES
Procedure
NL
Set-up conditions
3.
FR
Before draining the DHW tank, drain the heating (primary) circuit or bring its
pressure to 0 bar.
Water flowing out of the drain valve may be extremely hot and could cause severe
scalding. Keep people away from the hot water discharge.
4.
5.
6.
PL
RU
23
EN
DECLARATION OF CONFORMIT Y
FR
NL
ES
IT
DE
PL
RU
en