You are on page 1of 10

LG AIR CONDITIONER

INVERTER
SINGLE SPLIT

Why

LG Inverter
Single Split?

Recognizing the importance of saving energy, LG has taken the initiative to develop new, more efficient
inverter technology. In addition to consuming less electricity, the companys advanced inverter systems
also boast powerful performance and enhanced reliability.
LGs Inverter Single Split lowers energy usage and operational costs, illustrating how clever technology
can make a real difference. Designed for commercial spaces such as offices and retail stores, the new
model can operate for extended periods of time, while also providing exceptional energy efficiency.
The Inverter Single Split is able to produce an impressive volume of cool air; helping to create the
perfect indoor temperature in almost no time at all. As well as delivering fast and efficient cooling,
LGs latest solution can also minimize electricity consumption by as much as 27 percent.

Comfortable Operation
Once the desired temperature is achieved, unlike conventional air conditioners that turn the compressor on and off,
LG inverter units adjust and constantly vary the compressor speed to maintain the desired temperature with
minimal fluctuation to ensure that your comfort is not compromised.
Conventional

LG Inverter

Temprature

Temprature

Setting
Temprature

Setting
Temprature

Time
Room Temprature Power On

Power Off

Time
Room Temprature

Power On

Ceiling Cassette

kW

5.3

7.0

8.2

10.0

13.5

Indoor Unit Dimension

840 X 204 X 840

840 X 246 X 840

840 X 246 X 840

840 X 288 X 840

840 X 288 X 840

Outdoor Unit Dimension

870 X 655 X 320

870 X 655 X 320

950 X 834 X 330

950 X 834 X 330

950 X 1,380 X 330

R410A

R410A

R410A

R410A

R410A

Refrigerant

Ceiling Concealed Duct (Middle Static)

kW
Indoor Unit Dimension
Outdoor Unit Dimension

5.3

7.0

8.2

10.0

13.5

15.8

1,180 X 298 X 450 1,180 X 298 X 450 1,180 X 298 X 450 1,230 X 380 X 590 1,230 X 380 X 590 1,230 X 380 X 590
870 X 800 X 320

950 X 834 X330

950 X 834 X330

950 X 834 X330

R410A

R410A

R410A

R410A

Refrigerant

950 X 1,380 X 330 950 X 1,380 X 330


R410A

R410A

Ceiling Suspended

kW

5.3

7.0

8.2

Indoor Unit Dimension

950 X 650 X 220

1,350 X 650 X 220

1,350 X 650 X 220

1,750 X 650 X 220

1,750 X 650 X 220

Outdoor Unit Dimension

870 X 655 X 320

870 X 655 X 320

950 X 834 X 330

950 X 834 X 330

950 X 1,380 X 330

R410A

R410A

R410A

R410A

R410A

Refrigerant

10.0

13.5

2015 Air Conditioners

Top Tier EER


LGs Inverter Technology enable EER
to exceed competitors, world top
tier level. acquired with EER 11.6.

EER

11.6

Ceiling Cassette

Conventional

Cooling Only
11.6

11.6

11.6

9.5

9.5

9.5

5.3 kW

7.0 kW

8.2 kW

10 kW

13.5 kW

11.6

11.6

11.6
9.7

9.5

Cooling Only

11.6

9.5

9.5

9.5

5.3 kW

7.0 kW

8.2 kW

10 kW

Conventional

11.6
9.7

13.5 kW

Inverter

EER Saving

Cooling & Heating

11.6

11.6

11.6

11.6

11.6

11.6

11.6

9.6

9.5

9.6

9.5

9.5

7.0 kW

8.2 kW

10 kW

13.5 kW

15.8 kW

10.1

5.3 kW

11.6

11.6

11.6

11.6

9.5

9.6

9.5

9.5

7.0 kW

8.2 kW

10 kW

13.5 kW

15.8 kW

Conventional

Cooling Only

11.6

9.6

Ceiling Suspended

Inverter

EER Saving

Cooling & Heating


11.6

11.6

11.6

9.5

Ceiling Concealed Duct (Middle Static)

5.3 kW

EER Saving

Cooling & Heating

11.6

10.1

Inverter

11.6

11.6

11.6

11.6

11.6

11.6

11.6

11.6

9.5

9.5

9.5

9.5

9.5

9.5

9.5

9.5

9.5

9.5

5.3 kW

7.0 kW

8.2 kW

10 kW

13.5 kW

5.3 kW

7.0 kW

8.2 kW

10 kW

13.5 kW

Excellent
Energy Saving
LGs advanced inverter technology
leads to powerful performance while
minimizing energy consumption.
It will bring you greater cost saving
over the product life time.

Power
Consumption

27

SAVING

*Based on
10kW CCD model

Ceiling Cassette
EER

3.40
11.63.40
COP
COP
COP

World
World Top
Top Class
Class
World Top Class

(kWh)
(kWh)
(kWh)
6,000

6,000
6,000
5,000
5,000
5,000
4,000
4,000
4,000
3,000
3,000
3,000

World Top Class

Annual
Annual Power
Power Consumption
Consumption
Annual Power Consumption
5,103
5,103
5,103

18%%
18%

Conventional
Conventional
Conventional

4,185
4,185
4,185

LG
LG Inverter
Inverter
LG Inverter

Ceiling Concealed Duct (Middle Static)


EER

11.63.40
3.40
COP
COP
COP

World Top Class

World
World Top
Top Class
Class
World Top Class

(kWh)
(kWh)
(kWh)
12,000

12,000
12,000
10,000
10,000
10,000
8,000
8,000
8,000
4,000
4,000
4,000

Annual
Annual Power
Power Consumption
Consumption
Annual Power Consumption
10,854
10,854
10,854

27%%
27%

Conventional
Conventional
Conventional

7,938
7,938
7,938

LG
LG Inverter
Inverter
LG Inverter

Ceiling Suspended
(kWh)
(kWh)
(kWh)

EER

11.63.40
3.40
COP
COP
COP

World
World Top
Top Class
Class

World Top Class World Top Class

8,000
8,000
8,000
6,000
6,000
6,000
4,000
4,000
4,000
2,000
2,000
2,000

Annual
Annual Power
Power Consumption
Consumption
Annual Power Consumption
7,884
7,884
7,884

25%%
25%
Conventional
Conventional
Conventional

5,079
5,079
5,079

LG
LG Inverter
Inverter
LG Inverter

Note : 1. Calculation based on regional temperature condition of Riyadh, KSA


2. Operation duration : 9 hours/day (09:00~18:00) & 6 days / week
3. Ceiling Cassette : Based on 5.3kW
4. Ceiling Concealed Duct : Based on 10kW
5. Ceiling Suspended : Based on 8.2kW

2015 Air Conditioners

Quick
Cooling

30

Advanced VRF technology


Refrigerent Pressure Control
is applied, which ensures faster
and more accurate operation of
compressor to the optimum cooling
condition.

Conventional

Temperature Sensor Only

LG Inverter

Temperature Sensor

Quicker

Step 1

Step 2

Sensing current
temperature of
refrigerent, indoor and
outdoor temperature

Estimating Pressure
Finding recorded target pressure to
operate compressor, based on the
corresponding temperature data

Step 1

Pressure Sensor

Sensing refrigerent pressure and


temperature simultaneously to
make sure compressor ready for
target cooling operation

This ensures to reach


target performance point
without failing to keep a
reliable operation.

This algorithm is more


likely to be affected by
temperature change and it
takes more time to
calculate proper operation
range of compressor to
target point.

Direct
Sensing

Shorten Time to Reach Setting Temprature


It takes up to 30% less time to reach the desired
temperature with a high level of accuracy and stability.

Temprature

30%
Setting
Temprature

LG Inverter
Conventional

Time

Wide Operating Range


More accurate control of compressor operation from
pressure sensing mechanism ensures stable
performance against extreme outdoor conditions.

Wide Operation Range

0 c

Cooling Operation Range: 0oC ~ 54oC


7

54 c

Quiet
Operation

78dB
Typing

55dB
Office

50dB
Talking

39dB

LGs unique outdoor fan and BLDC


motor eliminates unnecessary noise
and allows smooth operation.
Additionally, night silence mode can
make more silent environment for
you.

40dB
Library

LG BLDC Fan Motor


Air Conditioner

* Based on 8.2kW Concealed Duct model indoor sound pressure


Low - 36dB / High 42dB

Improved Outdoor Fan

BLDC Fan Motor

Narrow hub blade & mogul trailing edge of Type 1 and


thick leading edge & saw shaped trailing edge in Type 2
fan improve operation with low noise level and high air
flow rate.

With strong torque and powerful ND magnetism inside


the motor, the BLDC motor provides large air volume
and high static pressure. Precise speed control makes
operation smoother. Both electrical and mechanical
noise is lower, and high speed operation is achieved.

Leading edge
thickening

Mogul trailing edge

526mm
Reverse hub

460mm
Saw tooth
trailing edge

BLDC Fan Motor

Narrow hub

Type 1

Type 2

* Applied to 8.2kW, 10.0kW,


13.5kW, and 15.8kW unit

* Applied to 5.3kW and


7.0kW unit

Night Silent Operation


Night Silent Operation can reduce noise level at night time
by setting dip switch on PCB in outdoor unit.
Outdoor Sound level

57dB

Day Time

Max

Capacity
(kW)

8dB

5.3 kW
7.0 kW
8.2 kW
10 kW
13.5 kW
15.8 kW

49dB

Night Time

Sound Pressure (dB)


Day
Night
50
46
50
46
52
47
52
47
57
49
57
49

Capacity

Load
Sound
Level

8 Hours

9 Hours
Night

Highest Outdoor
Temperature

Mode Start

2015 Air Conditioners

Mode End

Superior Reliability
& Comfort
Thanks to superior technologies, design excellence and thorough
consumer research, LG is able to offer some of the industrys best indoor
units. Delivering the ultimate in comfort and convenience, the companys
exceptional air conditioning solutions immediately enhance any indoor
environment.

Ceiling Cassette
Independent 4-way vane control
Individually controllable, each of the units four
vanes can be precisely adjusted within a range of
20 to 70 degrees. This intelligent system is
capable of memorizing wind direction settings,
guaranteeing the comfort of every person in the
room.
* This function is available with wired remote controller (PQRCVSL0Q)

Compact Size
Ultra slim and compact design saves space and
reduces installation costs.
The ceiling cassettes relatively small
dimensions make it suitable for a wide variety
of applications and settings.

20

5M

Model
5.3kW
7.0 ~ 8.2kW
10.0 ~13.5kW
Length Width : 840X840mm

High Ceiling Mode


High ceiling mode ensures powerful airflow
reaches every inch of space even in rooms
with a 4.2 meter ceiling height.

4.2m

70

Height
204 mm
246 mm
288 mm

Ceiling Concealed Duct (Middle Static)


E.S.P : External Static Pressure Control
Static pressure setting on the remote controller makes it easy
to adjust the BLDC motors fan speed during duct installation ,
so it enables to maintain the desired air volume and noise level
at a minimum irrespective of external static pressure change
due to diifferent installation environment from initial design.

Air
Volume

H
M
L

H
M
L

Air Volume
at 2mmAq
2

Air Volume
at 10mmAq
6

10

12

Static Pressure (mmAq)

Ceiling Suspended
One Touch Filter
An indicator on the units front panel notifies users when
the filter needs to be changed. The new one-touch feature
makes cleaning the filter much easier as well.

2015 Air Conditioners

10

You might also like