0 FEEDER PROTECTION
1.1 CONVENTIONAL
ANSI Codes
Details
Product
50N
Electromechanical Instantaneous
Single element Earth Fault Relay
Electromechanical Instantaneous
Three element Over Current
Relay
Electromechanical Non
Directional IDMT relay suitable
for Single phase Over Current or
Earth Fault Application
- SI characteristics
- LTI characteristics
- VI characteristics
- EI characteristics
CAG17
CDG11(ST)
CDG21/CDG23/CDG24
CDG31(ST)
CDG61/CDG63/CDG64
50
51N
50N,51N
51,51N
50,51,50N,51N
67N
67N
Electromechanical Directional
IDMT and Non Directional High
set Instantaneous relay suitable
for Single phase Over Current or
Earth Fault Application with
CAG37
CDG11
CDG12
CDG13
CDG14
CDG31/CDG33/CDG34
CDD21
CDD23
CDD24
67N
CDD31
CDD33
CDD34
Electromechanical Directional
IDMT and Directional High set
Instantaneous relay suitable for
Single phase Over Current or
Earth Fault Application with
-
50N
SI characteristics
VI characteristics
EI characteristics
SI characteristics
VI characteristics
EI characteristics
CDD41
CDD43
CDD44
CTIGM15
CTUM15
HORM4
ANSI Codes
Details
Product
50N,51N
MICOMP111
G
50N,51N
MICOM P120
87P
1.2 NUMERICAL
50,51,50N,51N
50,51,50N,51N,46,49,
46BC(I 2 /I 1 ),37,
50BF.
50,51,50N,51N,46,49,
46BC(I 2 /I 1 ),37,
50BF,79,
50,51,50N,51N,46,49,
46BC(I 2 /I 1 ),37,
50BF.
MICOM P111
MICOM P122
MICOM P123
MICOM P124
50,51,50N,51N,46,49,
46BC(I 2 /I 1 ),37,
50BF,79,67,67N,27,59,59N
Numerical Directional/non
directional three phase
overcurrent and earth fault relay
-
50,51,50N,51N,46,49,
46BC(I 2 /I 1 ),37,
50BF,79,67,67N,27,59,59N,VTS,
CTS,81U/O,
32,df/dt
50,51,50N,51N,46,49,
46BC(I 2 /I 1 ),37,
50BF,79,67,67N,27,59,59N,VTS,
CTS,81U/O,
32,df/dt,
25(OPTIONAL)
Start contacts
Blocking logic,
Measurements
RS232 & RS485 port
75 Event Records
5 Fault Records
5 Disturbance Records( each
of 3 seconds duration)
Communication on
MODBUS/IEC103
7 I/P & 8 O/P
Numerical Directional/non
directional three phase
overcurrent and earth fault relay
-
MICOMP130C
Start contacts
Blocking logic,
Measurements
RS232 & RS485 port
> 100 Event Records
8 Fault Records
8 Disturbance Records( each
of 2 seconds duration)
Communication on
MODBUS/IEC103
2 I/P & 8 0/P
IRIGB (OPTION)
Numerical Directional/non
directional three phase
overcurrent and earth fault relay
-
MICOM P127
Start contacts
Blocking logic,
Measurements
RS232 & RS485 port
> 100 Event Records
8 Fault Records
8 Disturbance Records( each
of 2 seconds duration)
Additional IO card
Communication on
MODBUS/IEC103/
IEC61850 (FUTURE)
IRIGB (OPTION)
MICOM P132
50,51,50N,51N,46,49,
46BC(I 2 /I 1 ),37,
50BF,79,67,67N,27,59,59N,VTS,
CTS,81U/O,
32,64R,
25(OPTIONAL)
Numerical Directional/non
directional three phase
overcurrent and earth fault relay
-
MICOM P141/2/3
Start contacts
Blocking logic,
Measurements
RS232 & RS485 port
250 Event Records
5 Fault Records
75 secs. Disturbance
Records
Additional IO card
Communication on
MODBUS/IEC103/
IEC61850(FUTURE)
FAULT LOCATOR
IRIGB (OPTION)
Details
49
46,49,50
46,49,50,50N,50LR
46,49,50N
46,49,50,50N
49,46,50,50N,51N,50LR,66
Product
CTMM 500
CTMFM 300
CTMFM 400
MCHNM(motPRO)
2.2 NUMERICAL
ANSI CODES
Details
Product
49,46,50,51,50N,51N,50LR,37
MICOMP211
49,46,50,51,50N,51N,50LR,37
MICOMP220
49,46,50,51,50N,51N,50LR,37,
50BF
MICOMP225
49,46,50,50N,51N,50LR,27,59,
81,32,50BF,87(Option)
MICOMP241/2/3
5 Fault Records
210 secs. of Disturbance
Records
Communication on
COURIER/ MODBUS
Logic Inputs upto 16
(OPTION)
Output Relays upto 16
(OPTION)
10 RTD ( OPTION)
Power and Energy
Measurement
Details
Product
67,67N,32,27,59,59N,81,df/dt,
dv
Numerical Comprehensive
Interconnector Protection Relay
MICOMP341
Measurements
RS232 & RS485 port
250 Event Records
5 Fault Records
75 secs. Disturbance
Records
Additional IO card
Communication on
COURIER/
MODBUS/IEC103
IRIGB (OPTION)
Details
87
32
59N
27TN
64R1&64R2
27/59
81O/U
64
Current Operated
Voltage Operated
Product
CAG34/MCAG34
FAC34/MFAC34
WCDM11
PVMM164
VDG14
PVMM163
VAEM21& CAEM33
VAGM22
MFVUM21/22
Current Operated
Voltage Operated
CAG14/MCAG14
FAC14/MFAC14
4.2 NUMERICAL
ANSI CODES
Details
Product
50,50N,51,51N,67,67N,64,
51V,27,59,59N,81U/O,
49,46, 50BF
MICOM P141
50,50N,51,51N,67,67N,64,
51V,21,27,59,59N,81U/O,
32,49,46,40,50BF
Numerical Comprehensive
Generatorn Protection Relay for
Generator less than 5 MW
- Measurements
- RS232 & RS485 port
- 250 Event Records
- 5 Fault Records
- 75 secs. Disturbance
Records
- Additional IO card
- Communication on
COURIER/
MODBUS/IEC103
- Programmable Logic
Scheme
- IRIGB (OPTION)
Numerical Comprehensive
Generatorn Protection Relay for
Generator more than 5 MW
MICOMP342
50,50N,51,51N,67,67N,64,
51V,21,27,59,59N,81U/O,
32,49,46,40,50BF,87,
27TN/59TN,50/27
Measurements
RS232 & RS485 port
250 Event Records
5 Fault Records
75 secs. Disturbance
Records
Additional IO card
Communication on
MICOM P343
COURIER/
MODBUS/IEC103
Programmable Logic
Scheme
IRIGB (OPTION)
ANSI Codes
Details
Product
21,SOTF,VTS,PSB
SHPM ( Quadramho)
ANSI Codes
Details
Product
21,SOTF,VTS,PSB,50,51,67,
67N,32,49,27,59,59N,810/U,
df/dt,50 LBB, 79
MICOM P430C
5.2 NUMERICAL
21,SOTF,VTS,PSB,50,51,67,
32,49,27,59,59N,810/U,50 LBB,
df/dt
POLYGON /CIRCULAR
Characteristics
- With 2 Binary I/P and 8 O/P
relays
- Measurements
- RS232 & RS485 port
- > 100 Event Records
- 8 Fault Records
- 8 Disturbance Records( each
of 2 seconds duration)
- Additional IO card
- Communication on
MODBUS/IEC103
- Programmable Scheme
Logic
- FAULT LOCATOR
Numerical Distance Protection
Scheme suitable for Three Pole
Tripping and Auto Reclose
-
POLYGON /CIRCULAR
Characteristics
Upto 10 Binary I/P and 22
O/P Relays
MICOM P433
21,SOTF,VTS,PSB,50,51,67,
32,49,27,59,59N,810/U,50 LBB,
df/dt,25 (Optional)
21,SOTF,VTS,PSB,50,51,67,
32,49,27,59,59N,810/U,50 LBB,
df/dt,25 ( Optional)
Measurements
RS232 & RS485 port
> 100 Event Records
8 Fault Records
8 Disturbance Records( each
of 2 seconds duration)
Additional IO card
Communication on
MODBUS/IEC103
Programmable Scheme
Logic
FAULT LOCATOR
IRIGB I/P (OPTION)
POLYGON /CIRCULAR
Characteristics
Upto 28 Binary I/P and 46
Binary O/P Relays
Measurements
RS232 & RS485 port
> 100 Event Records
8 Fault Records
8 Disturbance Records( each
of 2 seconds duration)
Additional IO card
Communication on
MODBUS/IEC103/
IEC61850 (FUTURE)
Programmable scheme Logic
IRIGB I/P (OPTION)
FAULT LOCATOR
MICOM P435
POLYGON /CIRCULAR
Characteristics
Upto 28 Binary I/P and 46
Binary O/P Relays
Measurements
RS232 & RS485 port
> 100 Event Records
8 Fault Records
8 Disturbance Records( each
of 2 seconds duration)
Additional IO card
Communication on
MODBUS/IEC103/
IEC61850 (FUTURE)
MICOM P437
21,SOTF,VTS,PSB,50,51,67,
32,49,27,59,59N,810/U,50 LBB,
25
21,SOTF,VTS,PSB,50,51,67,
32,49,27,59,59N,810/U,50 LBB,
25
MICOMP441
QUAD Characteristics
Upto 8 Binary Input and 14
Output Relays
Measurements
RS232 & RS485 port
250 Event Records
5 Fault Records
75 secs. Disturbance
Records
Additional IO card
Communication on
COURIER/
MODBUS/IEC103
Programmable Logic
Scheme
FAULT LOCATOR
21,SOTF,VTS,PSB,50,51,67,
32,49,27,59,59N,810/U,50 LBB,
25
QUAD Characteristics
Upto 16 Binary Input and 21
Output Relays
- Measurements
- RS232 & RS485 port
- 250 Event Records
- 5 Fault Records
- 75 secs. Disturbance
Records
- Additional IO card
- Communication on
COURIER/
MODBUS/IEC103
- Programmable Logic
Scheme
- IRIGB I/P (OPTION)
- IEC61850 ( FUTURE)
- FAULT LOCATOR
Numerical Distance Protection
Scheme suitable for Three Pole
Tripping and or Three pole Auto
Reclose
MICOMP442
MICOMP444
21,SOTF,VTS,PSB,50,51,67,
32,49,27,59,59N,810/U,50 LBB,
25
QUAD Characteristics
Upto 24 Binary Input and 46
Output Relays
- Measurements
- RS232 & RS485 port
- 250 Event Records
- 5 Fault Records
- 75 secs. Disturbance
Records
- Additional IO card
- Communication on
COURIER/
MODBUS/IEC103
- Programmable Logic
Scheme
- IRIGB I/P (OPTION)
- IEC61850 ( FUTURE)
- FAULT LOCATOR
Numerical Distance Protection
Scheme suitable for Three Pole
Tripping and or Three pole Auto
Reclose
-
TRULY SUBCYCLE
MHO/ QUAD ( software
selectable ) Characteristics
Delta Directional
Comparison
Upto 24 Binary Input and 32
Output Relays
Measurements
RS232 & RS485 port
250 Event Records
5 Fault Records
75 secs. Disturbance
Records
Additional IO card
Communication on
COURIER/
MODBUS/IEC103
Programmable Logic
Scheme
IRIGB I/P (OPTION)
IEC61850 ( FUTURE)
FAULT LOCATOR
6.0
ANSI Codes
Details
Product
87P,50,51,50N,51N,49,50BF,
46BC
MICOMP521
MICOM P542
MICOMP543
Outputs
Communication on
COURIER/
MODBUS/IEC103
- Programmable Logic
Scheme
Phase Segregated Current
Differential Protection
-
MICOMP545
CONVENTIONAL
ANSI Codes
64
87T
87T
24
Details
Restricted Earth Fault
protection using High
Impedance Circulating
Current Scheme.
Static Three Differential Relay
working on Biased
charateristics with an
operating time of around 45
msec.
- Two Winding
- Three Winding
Static Single Phase
Differential Relay working on
Biased charateristics with an
operating time of around 45
msec.
- Two Winding
- Three Winding
Over Fluxing Relays with
Inverse Characteristics
Product
CAG14
DTH31
DTH32
MBCH12/13
GTTM22
7.2
NUMERICAL
ANSI Codes
87,64,24
87,50,51,50N,51N
Details
Numerical Transformer
Differential Relay for
two/three winding transformer
with
- Event
- Fault
- Disturbance Records
- Remote Communication
Numerical comprehensivee
Transformer Differential
Relay for two winding
transformers with
-
87,64,24,50,51,50N,51N
MICOM P630C
Numerical comprehensivee
Transformer Differential
Relay for two winding
transformers with
-
Product
KBCH120/130
MICOM P632
87,64,24,50,51,50N,51N
Numerical comprehensive
Transformer Differential
Relay for three winding
transformers with
-
87,64,24,50,51,50N,51N
Numerical comprehensive
Transformer Differential
Relay for four Bias I/Ps
-
MICOM P633
MICOM P634
CONVENTIONAL
ANSI Codes
87BB
87BB
Details
Bus bar protection scheme on
Circulating Current principal
based on High Impedance
Scheme
- Electromechanical Current
Operated
- Static Voltage operated
Product
VTX31
Metrosil
FAC34
PBDCB
87BB
Static
Modular subrack design
Built in Buswire
Supervision Unit
- Provision of Initiation of
Busbar Protection via
external LBB
- Remote End Intertrip
Command Outputs
Bus bar protection scheme on
Circulating Current principal
based on Biased
Characteristics
- Static
- Modular subrack design
- Built in Buswire
Supervision Unit
- Built in Over Current
Check
- Provision of Initiation of
Busbar Protection via
external LBB
- Remote End Intertrip
Command Outputs
CAG34
PBLSB
8.2
NUMERICAL
ANSI Codes
87BB
87BB,50LBB,50,51,50N,51N
Details
Bus bar protection scheme on
Circulating Current principal
based on High Impedance
Scheme
Product
Current Operated
MICOMP12X/MICOMP14X
VTX31
Metrosil
MICOM P740
Details
Product
79
VARM 111
79
VAR41B
ANSI Codes
Details
Product
79
MICOMP123
KAVR100
50 LBB
50 LBB
MCTI39
MCTI 40
9.2 NUMERICAL
79,25
79,25
50 LBB
50 LBB
KAVR130
MICOMP122
MICOMP821
Details
Product
Generator application
Line application
SKE11
SKD11
10.2 NUMERICAL
ANSI Codes
25
Details
Numerical check synchronising relay
Product
KAVS 100
ANSI Codes
50,51,50N,51N,59,
59N
Details
Numerical comprehensive feeder
protection relay
Product
MICOMP127
Details
Pt fuse fail monitoring
Voltage balance relay
Multiplication/Annunciation Relays
Product
VAPM32
MVAPM32
VAA/MVAA
86
VAJH/MVAJ
86
86
86
95
95
2
2
VAJS
VAJC11/
MVAJM14
MVAJ054/10
4/204
VAX31/
MVAX31
VAX21
VTT11
VTT12