Coordination / Selectivity
Sequence-of-Operation
Relay Testing &
Simulation
Relay Test Set Interface
& Equipment
intuitive
integrated
Power System
Enterprise Solution
ETAP is the most comprehensive analysis platform for the design,
simulation, operation, control, optimization, and automation of
generation, transmission, distribution, and industrial power systems.
Dynamics
& Transients
Transient Stability
Generator Start-Up
Wind Turbine Generator
User-Defined Dynamic Model
Parameter Estimation
Distribution
Unbalanced Load Flow
Optimal Power Flow
Transformer Tap Optimization
Switching Sequence Mgmt.
Reliability Assessment
Optimal Capacitor Placement
GIS Map
Transmission
Line
Line Constants
Line Ampacity
Sag & Tension
HV DC Transmission Link
Monitoring
& Simulation
Advanced Monitoring
Energy Accounting
Real-Time Simulation
Event Playback
Load Forecasting
Star
Protective
Devices
Coordination & Selectivity
Sequence-of-Operation
Relay Test Set Interface
ARTTS
Relay Testing
& Simulation
Relay Test Set Equipment
ETAP Test Set Software
Energy
Management
System
Automatic Generation Control
Economic Dispatch
Supervisory Control
Interchange Scheduling
Reserve Management
Network
Analysis
Short-Circuit ANSI
Short-Circuit IEC
Arc Flash
Load Flow
Motor Acceleration
Cable Systems
Underground Thermal Analysis
Cable Pulling
Cable Ampacity
Cable Sizing
Power Quality
Harmonic Load Flow
Frequency Scan
Harmonic Filters
DC Systems
Load Flow
Short-Circuit
Control System Diagram
Battery Discharge
Battery Sizing
Ground Grid
Systems
Finite Element Method
IEEE 80 & 665 Methods
Panel Systems
Panels ANSI & IEC
Intelligent
Load Shedding
Load Preservation
Load Restoration
Load Shedding Validation
Intelligent
Substation
Substation Automation
Switching Management
Load Management
Data
Exchange
DataX
MS Access & Excel
CAD Interface
e-DPP Interface
SmartPlant Interface
Base
Package
Cable Ampacity & Sizing
Transmission Line Constants
Report Manager
Project Management Wizards
Output Report Comparator
Multi-D Database
Libraries
Star
Device Coordination
Intuitive, Intelligent, Integrated
StarView Toolbar
Capabilities
Batch print TCC plots & diagrams for various paper sizes
Graphical curve tracker with cross lines & time gap tools
Customizable reports
Benefits
Enables system engineers to easily & efficiently perform
protective device coordination studies
Provide an accurate & realistic operating characteristic,
time, & state of protective devices
Offers insight into troubleshooting false trips, relay misoperation, & mis-coordination
Graphical Adjustment
Device curves can be graphically adjusted in the Star View.
Handles are provided on the device characteristic curves to
identify adjustable regions. Available ranges for a selected
curve can be displayed and identified by clicking the Hide/
Show Range button. The available ranges are grayed out
when an adjustable curve is selected.
Sequence-of-Operation
Star Sequence-of-Operation evaluates, verifies, and confirms
the operation and selectivity of the protective devices for
various types of faults for any location directly from the oneline diagram and via normalized TCC curve views.
Sequence-of-Operation provides a system wide solution
for an accurate and realistic operating time and state of
protective devices, such as relay, fuse, circuit breaker, trip
devices, contactor, etc. The operation time is calculated for
each protective device based on its settings, time current
characteristic, and interlocks for a specified fault location
and type.
Functionalities
User-definable fault insertion location
View device operation sequence graphically
Device failure & backup operation
Detailed relay actions (27, 49, 50, 51, 51V, 59, 67, 79, 87)
Sequence of event viewer
Normalized (shifted) TCC curves
Phase & Ground faults (symmetrical & asymmetrical)
Flashing protective device via the one-line diagram
10
Graphical Animation of
Protective Device Operation
Normalized TCC Curve
Normalized (Shifted) TCC mode is an analysis feature in
ETAP Star View which is based on Sequence-of-Operation
calculation. This analysis mode provides a graphical view
of the operation times of protective devices based on their
corresponding settings and characteristics for specified
fault location and type. Normalized TCC mode graphically
displays the TCC curves of protective devices in relation to
one and another for a given fault.
11
Library Merge
ETAP allows merging of library files using the copy and merge
functions. The merge function allows you to merge a partial or
complete library file from one library to another library, making
it simple to manage the library content from various library files.
Library Checker
The checker access level is provided for verification of
changes to project engineering properties and libraries
data. This allows for control and validation of library data.
13
14
15
Steady-State Response
ETAP Star exports the relay settings and parameters to
ARTTS for current injection into the relay. Based on the
required range of the overcurrent and/or fault current, the
relay test set then injects multiple currents (single-phase or
three-phase) into the relay in order to reconstruct the relay
TCC curve based on the actual relay response. The relay
test points are then imported to ETAP Star for plotting and
comparison with the manufacturer published data.
Transient Response
The ability to simulate relay response under steady-state
and transient conditions during both fault and normal
system operating conditions provides the necessary tools
for protection engineers and technicians to confidently
determine and evaluate the design and operation of
protection system. Steady-state fault current provides only
a snapshot operation of the relay based on sustained
current. Transient fault simulation is necessary to
determine the actual response time of the relay based on
the distributed through fault containing AC and DC decay
current.
Relay Transient Response
16
Features
Intuitive graphical user interface
Virtual front panel control
Graphical vector control
Ramp test with ability to sequence tests for ramping any
parameter up or down at the same time
Threshold test for automatic determination of thresholds
(current, voltage, frequency, & phase angle)
Rate of change (gradient) tests for frequency, voltage, current,
phase-angle, & Vdc (Dx / Dt)
Sequence editor
Test of distance relays with direct import of relay characteristic
with RIO format
Test of distance relays with simulation of all types of faults:
single-phase, two-phase, two-phase-to-ground, & three-phase
Report manager for test report customization
Export results in Windows application formats
17
ARTTS-6
IEEE No.
Distance Relay
21
Synchronizing Device
25
Under/Over-Voltage Relay
27/59
32
Field Relay
40
Capabilities
46
47
48
50
51
55
60
64
67
78
79
Frequency Relay
81
85
Lockout Relay
86
87
91
92
Tripping Relay
94
18
RANGE
1
2
3
4
5
6
7
8
9
10
11
12
13
6X
6X
6X
3X
3X
3X
3X
3X
3X
3X
2X
1X
1X
CONNECTION
CURRENT
A
DIRECT
DIRECT
DIRECT
DIRECT
DIRECT
DIRECT
2 IN PARALLEL
2 IN PARALLEL
2 IN PARALLEL
2 IN SERIES
3 IN PARALLEL
6 IN PARALLEL
2 SERIES OF +2 IN PARALLEL
0-15
0-1.5
0-0.15
0-15
0-1.5
0-0.15
0-30
0-3
0-0.3
0-15
0-45
0-90
0-30
CONNECTION
VOLTAGE
V
0-125
0-12.5
0-1
0-250
0-125
POWER
VA
ZMAX
Ohm
RESOLUTION
160
240
480
0.35
0.35
0.35
0.44
0.44
0.44
0.18
0.18
0.18
0.71
0.12
0.06
0.35
230 A
23 A
2 A
230 A
23 A
2 A
460 A
46 A
5 A
230 A
690 A
1.38 mA
460 A
POWER
VA
ZMAX
Ohm
RESOLUTION
195
195
195
390
97
1.9 mV
190 V
19 V
3.8 mV
1.9 mV
80
100
160
RANGE
1
2
3
4
5
4X
3X
3X
1X
1X
DIRECT
DIRECT
DIRECT
2 IN SERIES
2 IN PARALLEL
1
2
3
4
5
4X
3X
3X
1X
1X
DIRECT
DIRECT
DIRECT
2 IN SERIES
2 IN PARALLEL
80
160
160
80
80
160
160
1125
195
195
390
97
4.6 mV
1.9 V
190 V
9.2 mV
4.6 mV
Specifications
Multi-tasking automatic test set designed for testing
protection relays, energy meters, & transducers.
Output: 6 x 15A (80 VA) , 4 x 300V (80 VA), 1 x 260 VDC
High accuracy: 0,1%, 0.05% (HP)
Analog measurement inputs
IEC 61850 protocol interface
USB & RS232 port
Controlled by laptop PC or local control by PDA
Lightweight: 18 kg (39.7 lb)
19
etap.com
Quality Assurance Commitment
ETAP is Verified and Validated (V&V) against field results, real system measurements, established programs, and hand calculations to ensure its technical accuracy.
Each release of ETAP undergoes a complete V&V process using thousands of test cases for each and every calculation module. ETAP Quality Assurance program is
specifically dedicated to meeting the requirements of:
ISO 9001:2000
10 CFR 21
ASME NQA-1
CAN/CSA-Q396.1.2
10 CFR 50 Appendix B
ANSI/ASME N45.2
ANSI/IEEE 730.1
ANSI N45.22