250
h
10@255 = 2550
250
*Interior span/spanning
Characteristic actions:
Permanent, gk
Variable, qk
Materials:
Characteristic strength of concrete, fck
Characteristic strength of steel, fyk
Unit weight of reinforced concrete
= 25 N/mm2
= 500 N/mm2
= 25 kN/mm3
Assumed:
Cover, C
Diameter bar,
= 25 mm
= 8 mm
DRZNR 2014/JKSB
t
y
= 5.52 kN/m2
= 1.00 kN/m2
= 6.52 kN/m2
= 4.00 kN/m2
= 14.81 kN/m2
Consider 1m width, wd = nd x 1 m
= 14.81 kN/m
14.81 kN/m
L = 2.80 m
DRZNR 2014/JKSB
F=wdL
M=FL/10 = wdL2/10
DRZNR 2014/JKSB
11.60 kNm
11.60 kNm
L = 2.80 m
VA
M at B = 0
2.80VA 11.6+11.6 (14.81 x 2.80) x 1.4 = 0
DRZNR 2014/JKSB
VB
Shear resistance OK
6.0 DEFLECTION (Cl. 7.4)
Percentage of required tension reinforcement
DRZNR 2014/JKSB
Spanning slab
Deflection OK
7.0 CRACKING
h = 110 mm
400 mm
Smax,slab
450 mm
Smax,slab
DRZNR 2014/JKSB
8.0 DETAILING
0.3L=840
0.3L=840
01
02
02
N
04
1750
03
h
04
01
03
250
Reinforcement
01 : H8 125
02 : H8 125
03 : H8 125
04 : H8 350
DRZNR 2014/JKSB
2550
250
Thickness, h
= 110 mm
Nosing, N
= 25 mm
Cover, C
= 25 mm
All unit in mm