You are on page 1of 11

TEST REPORT

Report No. HLD0083/2006


Page
1
of
3
Date
DEC. 18, 2006
BOLLA ENTERPRISE CO., LTD.
3Rd. Fl., No. 45, Alley 15, Lane 309, Sec. 3,
Hoping West Road, Taipei, Taiwan.
The following merchandise was submitted and identified by the vendor as:
Product Description:
Water Tight Safe Case
Style/Item No.:
AK-13M
Manufacture/Vendor: BOLLA ENTERPRISE CO., LTD.
Country of Origin:
China
We have tested the submitted sample(s) as requested and the following results were obtained:
Test Required:
Test for Degrees of Protection Provided by Enclosures
IPX7

IP Code
First characteristic numeral

Omitting

Second characteristic numeral

Degrees of protection against ingress of water

Test Methods & Results:


--- See attached sheets --Testing Period:

Dec. 06, 2006 ~ Dec. 18, 2006

Signed for and on behalf of


SGS Taiwan Ltd.

Owen Cheng
Asst. Manager
The content of this PDF file is accordance with the original issued reports for reference only. This Test Report cannot be reproduced, except in full, without prior written
permission of the Company. PDF

TEST REPORT
Report No. HLD0083/2006
Page
2
of
3
Test Method & Results:
Waterproof test (Degrees of protection against ingress of water-IPX7)
Test for Degrees of Protection Provided by Enclosures:
Test Equipment:
Name

IPX7/IPX8 Immersion Tank

Brand

Model

Serial No.

self-made

SGS-ETR-0201

000001

Lab Environmental Conditions:


Ambient temperature:
253
Relative humidity:
5520%RH
Specification:
Test method:
Reference to IEC 60529 Edition 2.1: 2001-02--IPX7
Test for protection against water:
Test means:
Completely immerse the specimen in water in its service position as
specified by client.
Test condition:
See below items marked

,
The lowest point of enclosures with a height less than 850 mm is

located 1000 mm below the surface of the water


The highest point of enclosures with a height equal to or greater than
850 mm is located 150 mm below the surface of the water
Test duration:
30 minutes
Test method:
As shown in photo
C,
D
Examine the protection against ingress water of specimen after this test.

The content of this PDF file is accordance with the original issued reports for reference only. This Test Report cannot be reproduced, except in full, without prior written
permission of the Company. PDF

TEST REPORT
Report No. HLD0083/2006
Page
3
of
3
Test Method & Results:
Degree of protection against ingress of water (IPX7)
Test Result
Style/Item No.

Check Item
1
2
3

AK-13M
Yes

Provide protection against ingress water?


(followed check item 1) If any water has entered, does the
water accumulate near the cable end or live parts?
Functional check

N/A
N/A

Note 1: N/A means


Not Appl
i
c
a
bl
e

.
Note 2:The check items in this test report for inspecting the degree of protection provided by enclosures are reference to the
requirements specified in IEC 60529 Edition 2.1:2001-02 and in accordance with the acceptance conditions specified
by client.

Picture Page

Photo
A
: Appearance of specimen.

Photo
B
: Appearance of specimen

Photo
C
: Test for protection against water

Photo
D
: Test for protection against water

--- End of Report --The content of this PDF file is accordance with the original issued reports for reference only. This Test Report cannot be reproduced, except in full, without prior written
permission of the Company. PDF

TEST REPORT
Report No. HL70054/2006
Page
1
of
3
Date
JUL. 11, 2006
BOLLA ENTERPRISE CO., LTD.
3Rd. Fl., No. 45, Alley 15, Lane 309, Sec. 3,
Hoping West Road, Taipei, Taiwan.
The following merchandise was submitted and identified by the applicant as:
Product Description:
Water Tight Safe Case
Style/Item No.:
AK-13M, AK-13L, AK-13XL
Buyer/Order No.:
BULLMANN GMBH.
Manufacturer/Vendor:
BOLLA ENTERPRISE CO., LTD.
Country of Origin:
China

We have tested the submitted sample(s) as requested and the following results were obtained:
Test Required:
1. Handle strength Test
2. Compression Test
3. Drop Test

Test Method & Results:


--- See attached sheets ---

Testing period:

JUL. 06, 2006 ~ JUL. 10, 2006

Signed for and on behalf of


SGS Taiwan Ltd.

Owen Cheng
Asst. Manager

TEST REPORT
Report No. HL70054/2006
Page
2
of
3
Test Method & Results:
1. Handle Tensile Testa. Secure the sample on the testing platform. (See photo B)
b. Apply an upward load to the handle of the sample until it was broken then record the Max.
broken load.
c. Testing machine: INSTRON 5581, Speed: 10 mm/min.
Results:
Water Tight
Safe Case
AK-13M
AK-13L
AK-13XL

Max. broken load (kgf)


272.5
249.3
203.6

2. Compression Testa. Secure the sample on the testing platform. (See photo C)
b. Apply a downward load to the sample by means of two metal plates until it was broken or deformed
then record the Max. broken load.
c. Testing machine: INSTRON 5581, Speed: 10 mm/min.
Results:
Water Tight
Max. broken load (kgf)
Results
Safe Case
AK-13M
4548.7
The safe case was deformed but didnt break.
AK-13L
3601.4
The safe case was broken. (See photo D)
AK-13XL
5000.0
The safe case was deformed but didnt break.
Remark: 1. The size of metal plate is 700 mm 700 mm.
2. The limit of testing machine is 5000 kgf.
3. Drop Testa. The sample shall be drop free fall from a height on the floor.
b. Examine the sample whether damage or not.
Results:
Water Tight
Safe Case
AK-13M
AK-13L
AK-13XL

Drop Height
0.5 m
No breakage
No breakage
No breakage

1.0 m
No breakage
No breakage
No breakage

1.5 m
No breakage
No breakage
No breakage

2.0 m
No breakage
No breakage
No breakage

TEST REPORT
Report No. HL70054/2006
Page
3
of
3
Picture Page

Photo A: Sample picture.

Photo B: Test method for handle tensile test.

Photo C: Test method for compression test.

Photo D: Break picture for compression test.

--- End of Report ---

TEST REPORT
Report No. HL70158/2006
Page
1
of
4
Date
JUL. 27, 2006
BOLLA ENTERPRISE CO., LTD.
The following merchandise was submitted and identified by the applicant as:
Product Description:
Water Tight Safe Case
Style/Item No.:
AK-13L
Buyer/Order No.:
KINCROME AUSTRALIA PTY LTD.
Manufacture/Vendor: BOLLA ENTERPRISE CO., LTD.
Country of Origin:
China

We have tested the submitted sample(s) as requested and the following results were obtained:
Test Required:
1. Test for protection against solid foreign objects (IP1X)
2. Waterproof test (IPX1)

Test Methods & Results:


--- See attached sheets ---

Testing Period:

JUL. 17, 2006 ~ JUL. 26, 2006

Signed for and on behalf of


SGS Taiwan Ltd.

Owen Cheng
Asst. Manager
The content of this PDF file is accordance with the original issued reports for reference only. This Test Report cannot be reproduced, except in full, without prior written
permission of the Company. PDF

TEST REPORT
Report No. HL70158/2006
Page
2
of
4
Test Method & Results:
1. Test for protection against solid foreign objects:
Test Equipment:
Name
Test Sphere Probe 50mm

Brand

Model

Serial No.

PTL

P10.09

9706194.21

Lab Environmental Conditions:


Ambient temperature:
253
Relative humidity:
5520%RH
Test Method/ Specification:
Test method:
Reference to IEC 60529 Edition 2.1: 2001-02--IP1X
The rigid sphere with 50.0mm in diameter, 20 mm long and edges free from
burrs is pushed against any openings of the enclosure with the force
specified in Table 7 in IEC 60529 Edition 2.1: 2001-02. Examine whether
the full diameter of the rigid sphere passes through any opening or not.
Test force:
50 N10 %
Specimen:
Style/ Item No.:
Quantity:

AK-13L/ No.1
1 piece

Test Result:
Check Item
Style/Item No.
AK-13L/ No.1

Does the full diameter of the rigid sphere pass through any
openings of the enclosure?

No

The content of this PDF file is accordance with the original issued reports for reference only. This Test Report cannot be reproduced, except in full, without prior written
permission of the Company. PDF

TEST REPORT
Report No. HL70158/2006
Page
3
of
4
Test Method & Results:
2. Waterproof test:
Test Equipment:
Name
Dip Box

Brand

Model

Serial No.

PTL

P01.38

5060074

Lab Environmental Conditions:


Ambient temperature:
253
Relative humidity:
5520%RH
Test Method/ Specification:
Test method:

Dripping Device:
Sample condition:
Distance between
specimen and drip box:
Rotation speed of turntable:
Eccentricity between
turntable and specimen:
Water flow rate:
Test Duration:

Reference to IEC 60529 Edition 2.1: 2001-02--IPX1


The test specimen is placed on the turntable in its normal operating
position under the drip box. The enclosure is tested for uniform flow of
vertically falling water drops over the whole area of the enclosure.
As shown in figure below and photo 5, 6
Non-operating
200 mm
1 r/minute
Approximately 100 mm
+0.5
1( 0 ) mm/minute (water level falling rate)
Total 10 minutes

Examine the protection against ingress water of specimen after this test.

The content of this PDF file is accordance with the original issued reports for reference only. This Test Report cannot be reproduced, except in full, without prior written
permission of the Company. PDF

TEST REPORT
Report No. HL70158/2006
Page
4
of
4
Test Method & Results:
Specimen:
Style/ Item No.:
Quantity:

AK-13L/ No.1
1 piece

Test Result:
Check Item
Provide protection against ingress water?
Style/Item No.
AK-13L/ No.1

Yes

The content of this PDF file is accordance with the original issued reports for reference only. This Test Report cannot be reproduced, except in full, without prior written
permission of the Company. PDF

TEST REPORT
Report No. HL70158/2006
Page
5
of
4
Picture Page

Photo
A
: Sample picture

Photo
B
: Sample picture

Photo
C
: Test for protection against solid
foreign objects

Photo
D
: Test for protection against solid
foreign objects

Photo
E
: Waterproof test

Photo
E
: Waterproof test

--- End of Report --The content of this PDF file is accordance with the original issued reports for reference only. This Test Report cannot be reproduced, except in full, without prior written