You are on page 1of 3

TM

SST=STEEL SQUARE TAPERED

Type

Catalog #

20'39' Mounting Height


Project
Date

Comments
Fixed Tenon
or Drilled

Prepared by

SPECIFICATION FEATURES
1 ASTM Grade steel base plate with ASTM A366 base cover.
2 Hand hole assembly 3" x 5" on SST poles.
3 Steel shaft 55,000 PSI. Shot blasted and painted with premium TGIC polyester powder coat.
4 Drilled or Tenon (specify).
5 Anchor bolt per ASTM A576 with (2) nuts, (2) flat washer, and (1) lock washer. Nuts, washers
and threaded portion of bolt are hot dip galvanized. 3" hook for 3/4" bolt. 4" hook for 1" bolt.
3
Mounting
Height
(MH)

POLE COMPATIBILITY MATRIX

Single w/Arm

2 @ 180

2 @ 90

3 @ 90

3 @ 120

TENON

[1]

[2]

[5]

[3]

[6]

[4]

ICON SMALL

0.69

1.38

1.38

1.84

1.84

2.07

ICON MEDIUM

1.09

2.18

2.18

2.86

2.86

3.20

ICON SMALL STRUCTURAL MOUNT

0.71

1.42

1.42

1.90

1.90

2.14

ICON MEDIUM STRUCTURAL MOUNT

1.11

2.22

2.22

2.92

2.92

3.27

VISION SMALL

1.27

2.54

2.54

3.60

3.60

4.13

VISION MEDIUM

1.6

3.20

3.20

4.50

4.50

5.55

VISION SMALL STRUCTURAL MOUNT

1.28

2.56

2.56

3.63

3.63

4.17

VISION MEDIUM STRUCTURAL MOUNT

1.82

3.64

3.64

4.96

4.96

5.62

PRODUCT

2
Hand Hole
12 5/16"

1
B

Base View
S

EPA + MOUNTING CONFIGURATIONS

DRILL
PATTERN

4 @ 90

ASCENT SMALL

0.85

1.70

1.70

2.35

2.35

2.68

ASCENT MEDIUM

1.35

2.70

2.70

3.83

3.83

4.56

STRUT SMALL

1.03

2.06

2.06

2.89

2.89

3.49

STRUT MEDIUM

1.64

3.28

3.28

4.70

4.70

5.77

X-FORM SMALL

1.15

2.30

2.30

3.20

3.20

3.81

X-FORM MEDIUM

2.1

4.20

4.20

6.00

6.00

7.50

See Drill Patterns on page 3.

BC

D
BP
AB

F O U R B O L T A N C H O R A G E [see ordering information]


PB=Bolt Projection
AB=Bolt Dimensions
D=Bolt Diameter

www.cooperlighting.com

Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes.

H=Bolt Dimensions

AVU082207

S S T STEEL SQUARE TAPERED

The following information illustrates the correct way to enter an order for SST7A30SGMM1G. The ordering designation is detailed as follows.

Steel
S

Mtg.
Height
MH
20
25
30
30
35
39

Square
S

Tapered
T

Catalog 1, 2
Number

Wall
Thickness

SST6A20SBZ
SST6A25SBZ
SST7A30SBZ
SST7D30SBZ
SST8A35SBZ
SST8A39SBZ

.120
.120
.120
.180
.120
.120

Shaft 3
Size
7

Base
Square
(In.)
S

Mounting
Height
(ft.)
30

Wall
Thickness
A

Bolt
Circle
Dia.
(In.)
BC

Bolt
Proj.
(In.)
BP

Shaft
Size
(In.)
B

Base
Type
S

Colors
GM

Fixture
Mounting
+ Type
M

Anchor
Bolt
Net.
Dia. +
Wt.
EPA (Sq. Ft.) 4
Length (In.)
(Lbs.)
At Pole Top
AB
80
90
100
Consult your INVUE Lighting Representative
Consult your INVUE Lighting Representative
Consult your INVUE Lighting Representative
Consult your INVUE Lighting Representative
Consult your INVUE Lighting Representative
Consult your INVUE Lighting Representative

No. +
Location
of Arms
1

Accessories
(Ground
Lug)
G

Max. Fixture
EPA (Sq. Ft.) 4
LoadInclude
2' Above Pole Top Bracket (Lbs.)
80
90 100

NOTES: 1 Catalog number includes pole with anchor bolts with double nuts.
(BEFORE INSTALLING ANCHOR BOLTS MAKE SURE PROPER ANCHOR BOLT TEMPLATE IS OBTAINED FROM COOPER LIGHTING).
2 Tenon size or machining for rectangular arms must be specified. Hand hole is located 180 from single arm.
3 Shaft size, base plate, anchor bolts and projections may vary slightlyall dimensions nominal.
4 EPAs based on shaft properties with wind normal to flat. EPAs calculated using base wind velocity as indicated plus 30% gust factor.

MOUNTING OPTIONS=FIXED
Designation
O.D.
Number
(in.)
1
2 3/8"
2
2 3/8"
3
3 1/2"
5
3"

TENON [add as suffix]


Length
O.D.
(in.)
3 1/2"
4"
5"
4"

LENGTH

ACCESSORIES
A=1/2" Tapped Hub 1
B=3/4" Tapped Hub 1
C=Convenience Outlet 2
G=Grounding Lug
(Max. Wire #8 AWG)
H=Additional Hand Hole and Cover
(12" Below Pole Top90 from Hand Hole)
NOTES=1 Location is 3' above base 90 from hand hole.
2 Outlet is located 4' above base and on same side of pole as hand hole,
unless specified otherwise. Receptacle not included, provision only.

NOTE: Specifications and dimensions subject to change without notice.

Visit our web site at www.cooperlighting.com


Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801

AVU082207

S S T STEEL SQUARE TAPERED

DRILL PATTERNS
(TYPE A)

(TYPE J)

(TYPE C)

(TYPE K)
.312'' [8 mm] dia. hole

2 1/8"
[54 mm]

2 1/8"
[54 mm]

3/4'' [20 mm]


dia. hole

2 1/2'' [64 mm]


1 1/4'' [32 mm]

2 3/4"
[70 mm]

2 3/4"
[70 mm]

3/4'' [20 mm]


dia. hole

16 3/8"
[416 mm]

12 23/32"
[322 mm]
3/4'' [20 mm]
dia. holes

3'' [77 mm]


1 1/2'' [39 mm]

(2) 3/8'' [10 mm]


dia. holes

.312'' [8 mm] dia. hole

(2) 9/16'' [15 mm]


dia. holes

3/4'' [20 mm]


dia. holes
3" [77 mm]

2 1/2" [64 mm]

1 1/2"
[39 mm]

1 1/4"
[32 mm]
(2) 3/8'' [10 mm]
dia. holes

(TYPE E)

(TYPE M)

(2) 9/16'' [15 mm]


dia. holes

(TYPE F)

(TYPE G)
.312'' [8 mm] dia. hole

2 13/16''
[71 mm] 3/4'' [20 mm]
dia. hole

2 5/16''
[59 mm]
3/4'' [20 mm]
dia. hole
2 7/16'' [124 mm]

7/8'' [23 mm]


3 7/8''
[99 mm]

2 3/4"
[70 mm]

2 3/4"
[70 mm]

11"
[280 mm]

15 7/8"
[405 mm]

3/4'' [20 mm]


dia. holes

4 7/8'' [124 mm]

(2) 3/8" [10 mm]


dia. holes

(2) 5/8'' [16 mm]


dia. holes

.312'' [8 mm] dia. hole

3 7/8" [99 mm]


3"
[77 mm]
(2) 3/8'' [10 mm]
dia. holes

3/4'' [20 mm]


dia. holes
4 7/8" [124 mm]
2 7/16"
[62 mm]
(2) 9/16'' [15 mm]
dia. holes

FIXTURE DRILLING OPTIONS [Note handhole position relative to drill locations]

Single

2 @180

3 @ 90

4 @ 90

2 @ 90

3 @ 120

2 @ 120

CAUTION: Cooper Lighting poles have been designed to support only the luminaires and equipment originally intended. Miscellaneous items such as pennants, signs, and decorations may cause pole failure because of overloading. Addition of these items voids The Cooper Lighting warranty. Cooper Lighting will, however, supply information regarding total loading capacity on request. Cooper Lighting poles are guaranteed only
when used in a pole/luminaire or floodlight combination. Any other application of poles, including application without a luminaire or floodlight, voids Cooper Lightings warranty.

NOTE: Specifications and dimensions subject to change without notice.

Visit our web site at www.cooperlighting.com


Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801

AVU082207

You might also like