CASES OF ASME BOILER AND PRESSURE VESSEL CODE
TABLE 1
FLAW ACCEPTANCE CRITERIA FOR 12 in. TO
LESS THAN 1 in. THICK WELD
Case 2235-3
Use of Ultrasonic Examination in Lieu of
Radiography
Section I and Section VIII, Divisions 1 and 2
Surface flaw
Subsurface flaw
0.087
0.143
0.18
0.18
GENERAL NOTES:
(a) t p the thickness of the weld excluding any allowable reinforcement. For a buttweld joining two members having different thickness at the weld, t is the thinner of these two thicknesses. If a
full penetration weld includes a fillet weld, the thickness of the
throat of the fillet weld shall be included in t.
(b) A subsurface indication shall be considered as a surface flaw if
the separation (S in Fig. 1) of the indication from the nearest
surface of the component is equal to or less than half the through
dimension (2d in Fig. 1, sketch [b]) of the subsurface indication.
a/t
CASE (continued)
2235-3
CASES OF ASME BOILER AND PRESSURE VESSEL CODE
TABLE 2
FLAW ACCEPTANCE CRITERIA FOR 1 in. TO 12 in. THICK WELD
1 in. t 212 in. [Note (1)]
Aspect
Ratio,
a/
Surface
Flaw,
a/t
Subsurface
Flaw,
a/t
Surface
Flaw,
a/t
Subsurface
Flaw,
a/t
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.031
0.033
0.036
0.041
0.047
0.055
0.064
0.074
0.083
0.085
0.087
0.034
0.038
0.043
0.049
0.057
0.066
0.078
0.090
0.105
0.123
0.143
0.019
0.020
0.022
0.025
0.028
0.033
0.038
0.044
0.050
0.051
0.052
0.020
0.022
0.025
0.029
0.033
0.038
0.044
0.051
0.058
0.067
0.076
GENERAL NOTES:
(a) t p thickness of the weld excluding any allowable reinforcement. For a buttweld joining two members
having different thickness at the weld, t is the thinner of these two thicknesses. If a full penetration weld
includes a fillet weld, the thickness of the throat of the fillet weld shall be included in t.
(b) A subsurface indication shall be considered as a surface flaw if separation (S in Fig. 1) of the indication
from the nearest surface of the component is equal to or less than half the through thickness dimension
(2d in Fig. 1, sketch [b]) of the subsurface indication.
NOTE:
(1) For intermediate flaw aspect ratio a/ and thickness t (212 in. < t < 4 in.) linear interpolation is
permissible.
TABLE 3
FLAW ACCEPTANCE CRITERIA FOR LARGER THAN 12 in. THICK WELD
Aspect
Ratio,
a/
Surface
Flaw,
a, in.
Subsurface Flaw,
a, in.
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.228
0.240
0.264
0.300
0.336
0.396
0.456
0.528
0.612
0.600
0.624
0.240
0.264
0.300
0.348
0.396
0.456
0.528
0.612
0.696
0.804
0.912
GENERAL NOTES:
(a) For intermediate flaw aspect ratio, a/ linear interpolation is permissible.
(b) t p the thickness of the weld excluding any allowable reinforcement. For a buttweld joining two members
having different thickness at the weld, t is the thinner of these two thicknesses. If a full penetration weld
includes a fillet weld, the thickness of the throat of the fillet weld shall be included in t.
(c) A subsurface indication shall be considered as a surface flaw if separation (S in Fig. 1) of the indication
from the nearest surface of the component is equal to or less than half the through thickness dimension
(2d in Fig. 1, sketch [b]) of the subsurface indication.
256
CASE (continued)
2235-3
CASES OF ASME BOILER AND PRESSURE VESSEL CODE
(1) Recording Criteria. Reflectors that produce a response greater than 20% of the reference level shall be investigated. Any reflector considered to be a flaw shall be
recorded regardless of amplitude. Alternatively, for methods or techniques that do not use amplitude recording levels, sized flaws longer than 40% of the acceptable surface
and subsurface flaws in Table 1, 2, or 3 shall be investigated. The maximum amplitude, location, and extent of
these reflectors shall be recorded. The operator shall determine whether the indication originates from a flaw or is a
geometric indication in accordance with (2) below. When
the reflector is determined to be a flaw the acceptance criteria of Table 1, 2, or 3 shall apply.
(2) Geometric. Ultrasonic indications of geometric
and metallurgical origin shall be classified as follows:
(a) Indications that are determined to originate
from the surface configurations (such as weld reinforcement or root geometry) or variations in metallurgical
structure of materials (such as cladding to base metal
interface) may be classified as geometric indications, and
(1) need not be characterized or sized in
accordance with (i)(3) below;
(2) need not be compared to allowable flaw
acceptance criteria of Table 1, 2, or 3;
(3) the maximum indication amplitude and
location shall be recorded, for example: internal attachments, 200% DAC maximum amplitude, one (1) in.
above the weld centerline, on the inside surface, from
90 to 95 deg.
(b) The following steps shall be taken to classify
an indication as geometric:
(1) Interpret the area containing the reflector
in accordance with the applicable examination procedure;
(2) Plot and verify the reflector coordinates,
provide a cross-sectional display showing the reflector
position and surface discontinuity such as root or counterbore; and
(3) Review fabrication or weld prep drawings.
(c) Alternatively, other NDE methods or techniques may be applied to classify an indication as
geometric (e.g., alternative UT beam angles, radiography, ID and/or OD profiling).
(3) Flaw Sizing. Flaws shall be sized in accordance with a procedure qualified by demonstration
on similar reflectors at similar material depths. The
dimensions of the flaw shall be determined by the
rectangle that fully contains the area of the flaw.
(Refer to Figs. 15.)
The acceptance limits specified in this Case are based upon workmanship considerations and are not necessarily intended for use in
evaluating flaws identified after the vessel has gone into service.
257
CASE (continued)
2235-3
CASES OF ASME BOILER AND PRESSURE VESSEL CODE
t
2d
S
S ^d
(a)
(b)
Surface Indications
t
2a
S 1a
(c) Subsurface Indications
Alternatively, the review may be achieved by arranging for a data acquisition and initial interpretation by
a Level II individual qualified in accordance with
paras. (f) and (h) above, and a final interpretation and
evaluation shall be performed by a Level III individual
qualified similarly. The Level III individual shall have
been qualified in accordance with para. (f) above,
including a practical examination on flawed specimens.
(k) The nameplate shall be marked under the Code
Symbol stamp by applying UT, to indicate ultrasonic
examination of welded seams required to be inspected
in accordance with Section I or Section VIII, Division
1 or 2.
(l) This Case number shall be shown on the Manufacturers Data Report, and the extent of the UT examination shall be noted.
258
CASE (continued)
2235-3
CASES OF ASME BOILER AND PRESSURE VESSEL CODE
CASE (continued)
2235-3
CASES OF ASME BOILER AND PRESSURE VESSEL CODE
FIG. 3
260
CASE (continued)
2235-3
CASES OF ASME BOILER AND PRESSURE VESSEL CODE
CASE (continued)
2235-3
CASES OF ASME BOILER AND PRESSURE VESSEL CODE
262