Professional Documents
Culture Documents
PRESENTACIN
realidad
fin
enriquecer
nuestros
competencias que caracterizan a un ingeniero, la cual nos permitir competir con mis futuros
colegas.
INDICE
1.
MEMORIA DESCRIPTIVA:....................................................................................................................................................................1
1.1.
OBJETIVOS DEL PROYECTO:.................................................................................................................................................1
1.2.
GENERALIDADES.......................................................................................................................................................................1
1.2.1.
Titular:........................................................................................................................................................................................1
1.2.2.
Emplazamiento:.........................................................................................................................................................................1
1.2.3.
Localidad:...................................................................................................................................................................................1
1.2.4.
Tipo de edificacin:...................................................................................................................................................................1
1.2.5.
Potencia instalada en (W):.......................................................................................................................................................2
1.2.6.
Presupuesto total:......................................................................................................................................................................2
1.3.
DESCRIPCIN DEL PROYECTO:...........................................................................................................................................2
1.4.
ALCANCES DEL PROYECTO:.................................................................................................................................................3
2. PLANOS:....................................................................................................................................................................................................4
2.1.
PLANO DE UBICACIN:.............................................................................................................................................................4
2.2.
PLANO DE DISTRIBUCIN:.......................................................................................................................................................5
2.3.
PLANO DE ELEVACIN Y FACHADAS:...................................................................................................................................6
3. ALCANCE DE LAS INSTALACIONES ELCTRICAS:...................................................................................................................6
3.1.
INST. ELECT. DE CORRIENTE FUERTE:.............................................................................................................................6
3.2.
INST. ELECT. DE CORRIENTE DBIL:.................................................................................................................................7
3.3.
INST. ELECT. ELECTROMECNICAS:.................................................................................................................................7
3.4.
INST. ELECT. ESPECIALES:.....................................................................................................................................................7
3.5.
BASES DE CLCULO:................................................................................................................................................................7
4. CLCULOS DE CARGAS JUSTFCATIVOS:.....................................................................................................................................7
4.1.
ALUMBRADO:..............................................................................................................................................................................7
4.2.
NUMERO DE LUMINARIAS POR CADA AMBIENTE:.....................................................................................................10
4.3.
POTENCIA INSTALADA Y MXIMA DEMANDA DE CADA AMBIENTE EN TODOS LOS NIVELES:...............20
4.4.
CALCULO DE LA MXIMA CORRIENTE, ELECCIN DE LA SECCIN DEL CONDUCTOR, DISPOSITIVO
DE PROTECCIN Y CONDUCTOS DE TUBERA............................................................................................................................26
4.5.
TOMA CORRIENTES:..............................................................................................................................................................27
4.6.
INTERRUPTORES:...................................................................................................................................................................27
4.7.
OTRAS INSTALACIONES:......................................................................................................................................................28
5. CIRCUITOS DE ALUMBRADO:........................................................................................................................................................29
5.1 REGLA DEL ALUMBRADO:.............................................................................................................................................................29
5.2. CADA DE TENSIN:........................................................................................................................................................................29
6. PUESTA A TIERRA:..............................................................................................................................................................................30
7. ELEMENTOS DE PROTECCIN:......................................................................................................................................................31
8. METRADO Y PRESUPUESTO:..........................................................................................................................................................32
8.1.
DESARROLLO DEL METRADO:..........................................................................................................................................32
8.2.
COSTOS Y METRADOS:..........................................................................................................................................................33
9. CONCLUSIONES:..................................................................................................................................................................................35
10.
BIBLIOGRAFA:.............................................................................................................................................................................36
11.
ANEXOS:..........................................................................................................................................................................................37
PROYECTO:
INSTALACIN ELCTRICA INTERIOR DE UNA VIVIENDA MULTIFAMILIAR
1.
MEMORIA DESCRIPTIVA:
1.1.
1.2.
GENERALIDADES
El presente trabajo trata sobre el proyecto integral de las instalaciones elctricas Interiores que
se ejecutarn en una vivienda multifamiliar.
El proyecto de diseo se desarrollar, en base a las disposiciones del cdigo Nacional de
Electricidad, normas tcnicas peruana del DGE - MINEM, en base a los planos de arquitectura
y para la ejecucin se deber tener en cuenta el Reglamento Nacional de Construccin.
Se edificara una casa habitacin de vivienda multifamiliar tpico de cuatro niveles. Con un
permetro de 49.03 m. y un rea total de 134.472 m2.
El proyecto comprende el desarrollo de las Instalaciones Elctricas a nivel de Alimentadores a
los Tableros de Distribucin e Instalaciones de Interiores. Universidad Nacional del Altiplano
- Puno 3
Adems el proyecto de instalacin elctrica comprende: Los alcances del trabajo, la descripcin
de las instalaciones, las especificaciones tcnicas procedimientos que regirn en su ejecucin,
para dejar en perfecto estado de funcionamiento.
La supervisin del proyecto elctrico estar a cargo de un Ingeniero Electricista o
Mecnico Electricista colegiado.
1.2.1.
Titular:
Nombre: Manuel Ccari Vilcapaza
1.2.2.
Emplazamiento:
JR. TACNA Nro. 340
1.2.3.
Localidad:
DISTRITO: Azngaro
PROVINCIA: Azngaro
1.2.4.
Tipo de edificacin:
Se trata de una edificacin de tipo residencial
1.2.5.
1.2.6.
Presupuesto total:
2
1.3.
SISTEMAS DE COMUNICACIN:
En este caso, solo se est considerando los circuitos de timbre, intercomunicador, estos
estn compuestos por alimentadores de conductores TW (1.5 mm2) y tubo de PVC-P de
25 mm. De dimetro, pulsador y timbre con su respectivo transformador.
d) SISTEMAS ESPECIALES:
En este caso de sistemas especiales se tendr casos especiales como sistemas contra
descargas atmosfricas, proteccin de todo el sistema contra accidentes no deseados.
Por puesta a tierra de proteccin se entiende la conexin de determinados elementos de
una instalacin elctrica con el potencial de tierra, asegurando la actuacin de los
elementos de proteccin y evitando tensiones de contacto peligrosas para las personas. La
instalacin de la puesta a tierra se logra, entre otras alternativas, mediante el empleo de
electrodos enterrados cuyas caractersticas dependen de aspectos como la calidad del
suelo, parmetros elctricos del sistema y la superficie de terreno disponible. Es
importante mencionar que para puesta a tierra de proteccin NO deben ser utilizados las
3
Mnimo
Recomendado
ptimo
50
100
150
100
150
200
Aulas, laboratorios
300
400
500
300
500
750
450
500
750
500
750
1000
300
500
750
500
750
1000
Centros docentes
Oficinas
Comercios
Comercio tradicional
Grandes superficies,
salones de muestras
supermercados,
200
300
500
500
750
1000
1000
1500
2000
Dormitorios
100
150
200
Cuartos de aseo
100
150
200
Cuartos de estar
200
300
500
Cocinas
100
150
200
300
500
750
Viviendas
2. PLANOS:
El proyecto se desarrollar en los siguientes planos: se establece en los anexos del
2.1.
DESCRIPCIN
Plano de ubicacin
Plano de distribucin
Elevacin y corte transversal
Instalaciones elctricas
Tableros de distribucin
Plano de puesta a tierra
UBICACIN:
ESCALA
Informe S/E
1/50
1/50
1/50
Informe S/E
1/50
proyecto.
PLANO DE
El inmueble de material noble se encuentra ubicado en el jirn puno con el jirn Tacna 340 del
barrio Vilcapaza de la provincia de Azngaro - Puno. Propiedad de la Sr. Manuel Ccari
Vilcapaza y la Sra. Juana Ticona Quispe, verificado para tal efecto las dimensiones del terreno.
Siendo las siguientes:
Por el este: Benito torres sucari con una medida de 16.19 m.
Por el oeste: Con el jirn Tacna, Con una medida de 15.60m.
Por el norte: Con el jirn puno, Con una medida de 10.39m.
Por el sur: Ronald Canahuire Mamani con una medida de 6.85m.
5
Correspondiendo para este terreno con las medidas antes mencionadas un permetro de 49.03
m. y un rea total de 134.472 m2.
DE
DISTRIBUCIN
PARA
LA
VIVIENDA
C-1
ALUMBRADO
PVC - 20 mm L - 2 - 2.5 mm TW
C-2
ALUMBRADO
PVC - 20 mm L - 2 - 2.5 mm TW
C-3
TOMACORRIENTES
PVC - 20 mm L - 2 - 2.5 mm TW + 1 - 2.5 mm Cu
C-4
TOMACORRIENTES
PVC - 20 mm L - 2 - 2.5 mm TW + 1 - 2.5 mm Cu
C-5
COCINA ELECTRICA
PVC - 20 mm P - 2 - 4 mm TW + 1 - 2.5 mm Cu
C-6
THERMA ELECTRICA
PVC - 20 mm P - 2 - 2.5 mm TW + 1 - 2.5 mm Cu
C-7
AIRE ACONDICIONADO
PVC - 20 mm P - 2 - 2.5 mm TW + 1 - 2.5 mm Cu
Sistemas de Alumbrado.
Sistemas de Tomacorriente.
Sistemas de uso domestico.
Sistemas de fuerza segn la carga necesaria.
Otros.
rea(m2)
22.027
5.85
6.6
14.1
5.355
10.2
8.99
5.5
3.20
2.907
3.06
9.72
7.40
8.40
AMBIENTE
GARAJE
COCINA
PATIO
SALA + COMEDOR
ESTUDIO
DORMITORIO 1
DORMITORIO 2
CURTO DE SEVICIOS
SSHH CUARTO DE SEVICIOS
SSHH SALA+COMEDOR
SSHH DORMITORIO 1-2
PASILLO
JARDIN
PUERTA Y VEREDA EXTERIOR
PAREDES
Caf claro
Crema
crema
Crema
Celeste
Rosado
Rosado
amarillo
Celeste
Celeste
celeste
Amarillo
Verde limn
Celeste
SEGUNDO NIVEL
PAREDES
AMBIENTE
Crema
COMEDOR
Crema
COCINA
crema
LAVANDERIA
Crema
CURTO DE SEVICIOS
Rosado
DORMITORIO 1
DORMITORIO 2
ESTUDIO
SSHH
CUARTO
SEVICIOS
SSHH DORMITORIO 2
SSHH PASILLO
PASILLO
GRADAS O ESCALERA
TECHO
Blanco
Blanco
Blanco
Blanco
Blanco
Blanco
Blanco
Blanco
Blanco
Blanco
Blanco
Blanco
Blanco
Blanco
TECHO
Rosado
Celeste
Blanco
Blanco
Blanco
Blanco
Blanco
Blanco
Blanco
amarillo
Celeste
Celeste
Amarillo
Amarillo
Blanco
Blanco
Blanco
Blanco
Blanco
DE
Rosado
Celeste
Blanco
Blanco
amarillo
Blanco
DE
10
SSHH DORMITORIO 2
SSHH PASILLO
PASILLO
GRADAS O ESCALERA
Celeste
Blanco
Celeste
Amarillo
Amarillo
Blanco
Blanco
Blanco
Determinamos el nivel de iluminancia media (Em). Este valor depende del tipo de
actividad a realizar en el local y podemos encontrarlos tabulados en las normas y
recomendaciones elctricas, en nuestros caso ya se determin anteriormente.
Se escoge el tipo de lmpara (incandescente, fluorescente...) ms adecuada de acuerdo con
el tipo de actividad a realizar.
Se escoge el sistema de alumbrado que mejor se adapte a nuestras necesidades y las
luminarias correspondientes.
Determinamos la altura de suspensin de las luminarias segn el sistema de iluminacin
escogido.
h: altura entre el plano de trabajo y
las luminarias.
h: altura del local.
d: altura del plano de trabajo al
techo.
d: altura entre el plano de trabajo
y las luminarias.
Altura de las luminarias
Locales de altura normal (oficinas, viviendas,
aulas...)
11
Lo ms altas posibles
Mnimo: h
2
(h` 0.85)
3
ptimo: h
4
(h` 0.85)
5
d`
1
(h` 0.85)
4
h`
3
(h` 0.85)
4
ab
h(a b)
3ab
2(h 0.85)(a b)
Donde k es un nmero comprendido entre 1 y 10. A pesar de que se pueden obtener valores
mayores de 10 con la frmula, no se consideran pues la diferencia entre usar diez o un
nmero mayor en los clculos es despreciable.
Determinamos los coeficientes de reflexin de techo, paredes y suelo. Estos valores se
encuentran normalmente tabulados para los diferentes tipos de materiales, superficies y
acabado. Para lo cual podemos tomarlos de la siguiente tabla.
Techo
Paredes
Suelo
Color
Blanco o muy claro
claro
medio
claro
medio
oscuro
claro
oscuro
Factor de reflexin ( )
0.7
0.5
0.3
0.5
0.3
0.1
0.3
0.1
Determinamos el factor de utilizacin ( , CU) a partir del ndice del local y los factores de
reflexin. Estos valores se encuentran tabulados y los suministran los fabricantes. En las
tablas encontramos para cada tipo de luminaria los factores de iluminacin en funcin de
los coeficientes de reflexin y el ndice del local. Si no se pueden obtener los factores por
lectura directa ser necesario
12
E S
fm
Donde:
-
T
L
Donde:
-
N es el nmero de luminarias.
T es el flujo luminoso total.
L es el flujo luminoso de una lmpara.
N es el nmero de lmparas por luminaria.
ILUMINACIN CONVENCIONAL:
Se ha empleado el sistema de iluminacin directa con artefactos fluorescentes e
incandescentes.
13
GARAJE
COCINA
PATIO
SALA + COMEDOR
22.02
7
5.85
6.6
14.1
150
50
50
150
0.982
4
1.064
1
0.954
7
1.224
7
30
30
50
30
70
70
70
70
0.2
2
0.2
4
0.2
7
0.65
0.7
0.65
0.3
0.7
14
9648.9510
5
9377.3809
5
6760.6837
6
16952.142
9
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
T5 365
0
T5 365
0
T5 365
0
T5 365
0
2
2
1
2
N DE LUMINARIAS CALCULADAS
LMPARAS /LUMINARIAS
TIPO DE LMPARA
FLUJO TOTAL ()
FACTOR DE MANTENIMIENTO
FACTOR DE UTILIZACIN ()
TECHO
REA (m)
AMBIENTE
PARED
REF (%)
1.321
7
1.284
5
0.926
1
2.322
2
TOTAL DE LMPARAS
ESTUDIO
5.355
50
DORMITORIO 1
10.2
100
DORMITORIO 2
8.99
100
CURTO DE SEVICIOS
SSHH CUARTO DE
SEVICIOS
SSHH
SALA+COMEDOR
SSHH DORMITORIO
1-2
5.5
50
3.20
50
2.907
50
3.06
100
PASILLO
9.72
50
JARDIN
7.40
50
PUERTA Y VEREDA
8.40
100
PASILLO COCINA
2.907
50
0.451
5
0.820
9
0.681
1
0.357
6
0.979
3
0.332
8
1.110
6
0.320
6
0.997
8
0.322
2
0.986
4
30
70
10
30
30
30
30
70
30
70
30
70
30
70
30
70
30
70
30
70
30
70
0.1
0.1
3
0.1
4
0.0
9
0.2
2
0.0
8
0.2
7
0.0
8
0.2
2
0.0
8
0.2
2
0.65
0.65
0.65
0.65
0.7
0.65
0.7
0.65
0.7
0.65
0.7
15
5243.0769
2
5595.2662
7
3049.4505
5
4435.8974
4
28375.324
7
3284.6153
8
26931.746
3019.2307
7
26918.181
8
3009.6153
8
21315.584
4
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
T5 365
0
T5 365
0
T5 365
0
T5 365
0
T5 365
0
T5 365
0
T5 365
0
T5 365
0
T5 365
0
T5 365
0
T5 365
0
1
2
2
1
1
1
1
2
2
2
1
0.718
2
0.766
4
0.417
7
0.607
6
3.887
0
0.449
9
3.689
2
0.413
5
3.687
4
0.412
2
2.919
9
COMEDOR
COCINA
LAVANDERIA
12.4
43
9.15
6
3.76
10
0
10
0
10
0
0.9824
1.0641
0.9547
3
0
3
0
5
0
7
0
7
0
7
0
0.22
0.24
0.27
0.65
0.7
0.65
16
9648.951
05
9377.380
95
6760.683
76
FLUORESENTE T5 3650
de 35W
FLUORESENTE T5 3650
de 35W
FLUORESENTE T5 3650
de 35W
4
1
1
N DE LUMINARIAS CALCULADAS
LMPARAS /LUMINARIAS
TIPO DE LMPARA
FLUJO TOTAL ()
FACTOR DE MANTENIMIENTO
FACTOR DE UTILIZACIN ()
REA (m)
AMBIENTE
PARED
TECHO
REF
(%)
1.321
7
1.284
5
0.926
1
TOTAL DE LMPARAS
CURTO
SEVICIOS
DE
5.85
DORMITORIO 1
10
DORMITORIO 2
9.65
ESTUDIO
6.30
SSHH CUARTO DE
SEVICIOS
3.20
SSHH
DORMITORIO 2
3.12
SSHH PASILLO
PASILLO
GRADAS
ESCALERA
3.30
9.72
O 8.80
1
50
10
0
10
0
10
0
1.2247
50
0.3576
50
0.9793
50
10
0
10
0
0.3328
0.4515
0.8209
0.6811
1.1106
0.3206
3
0
3
0
1
0
3
0
3
0
3
0
3
0
3
0
3
0
7
0
7
0
3
0
3
0
7
0
7
0
7
0
7
0
7
0
0.3
0.7
0.1
0.65
0.13
0.65
0.14
0.65
0.09
0.65
0.22
0.7
0.08
0.65
0.27
0.7
0.08
0.65
17
16952.14
29
5243.076
92
5595.266
27
3049.450
55
4435.897
44
28375.32
47
3284.615
38
26931.74
6
3019.230
77
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
T5 3650
T5 3650
T5 3650
T5 3650
T5 3650
T5 3650
T5 3650
T5 3650
T5 3650
1
2
2
2
1
1
1
2
2
2.322
2
0.718
2
0.766
4
0.417
7
0.607
6
3.887
0
0.449
9
3.689
2
0.413
5
COCINA
LAVANDERIA
9.219
3.76
30
30
50
7
0
7
0
7
18
4
1
1
N DE LUMINARIAS CALCULADAS
0.7
0.65
FLUORESENTE T5 3650
de 35W
FLUORESENTE T5 3650
de 35W
FLUORESENTE T5 3650
LMPARAS /LUMINARIAS
0.24
0.27
9648.951
05
9377.380
95
6760.683
0.65
TIPO DE LMPARA
0.22
FLUJO TOTAL ()
0.982
100 4
1.064
100 1
100 0.954
FACTOR DE MANTENIMIENTO
14.26
9
FACTOR DE UTILIZACIN ()
SALA + COMEDOR
REA (m)
AMBIENTE
PARED
TECHO
REF
(%)
1.321
7
1.284
5
0.926
TOTAL DE LMPARAS
2
1
2
2
CURTO
SEVICIOS
DE
5.85
DORMITORIO 1
10
DORMITORIO 2
9.65
ESTUDIO
6.30
SSHH CUARTO DE
SEVICIOS
3.20
SSHH DORMITORIO
2
3.12
SSHH PASILLO
3.30
PASILLO
GRADAS
ESCALERA
9.72
O
8.801
7
1.224
50 7
0.451
100 5
0.820
100 9
100 0.6811
0.357
50 6
0.979
50 3
0.332
50 8
30
30
10
30
30
30
30
100 1.1106 30
0.320
100 6
30
0
7
0
7
0
3
0
3
0
7
0
7
0
7
0
7
0
7
0
0.3
0.1
0.13
0.14
0.09
0.22
0.7
0.65
0.65
0.65
0.65
0.7
0.08
0.65
0.27
0.7
0.08
0.65
19
76
16952.14
29
5243.076
92
5595.266
27
3049.450
55
4435.897
44
28375.32
47
3284.615
38
26931.74
6
3019.230
77
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
FLUORESENTE
de 35W
T5 3650
T5 3650
T5 3650
T5 3650
T5 3650
T5 3650
T5 3650
T5 3650
T5 3650
2
2
1
2.322
2
0.718
2
0.766
4
0.417
7
0.607
6
3.887
0
0.449
9
3.689
2
0.413
5
CUARTO DE SERVICIOS
COCINA
SALA + COMEDOR
PATIO
JARDN
PASILLO SALA
DORMITORIO 1
DORMITORIO 2
DESCRIPCIN
4 lmparas fluorescente
2 lmparas encandcete
1lampara
2 lmparas
TV de 21
Una radio
Mini componente
2 lmparas
Refrigeradora
Horno microondas
Licuadora
Cocina elctrica de 3 hornilla
Olla arrocera
Extractor de jugo
Radio
Intercomunicador
4 lmparas por cada nivel
TV de 29
Radio
Reproductor DVD
Equipo de msica
Ventilador
Telfono
Una ducha elctrica
1 lmparas
2 lmparas
2 lmparas
2 lmparas
TV de 29
Reproductor DVD
Radio
Plancha
2 lmparas
20
P.I.(W)
140
200
40
70
120
40
110
70
350
1200
450
3500
1000
100
100
50
140
140
100
200
80
100
50
3000
35
70
70
70
140
200
40
1000
70
ESTUDIO
SSHH
SSHH SALA + COMEDOR
TV de 29
Reproductor DVD
Radio
Plancha
1 lmparas
Una computadora
Impresora lser
Ventilador de pie
1 lmparas
ducha elctrica
1 lmparas por cada SSHH
ducha elctrica
2 lmparas
ducha elctrica
1/2Hp
SSHH DORMITORIO
1-2
ELECTROBOMBA
LMPARAS SOBRE LA
3 lmpara adicional en el exterior 40W c/u
CALLE
POTENCIA TOTAL INSTALADA
140
200
40
1000
45
140
200
40
35
3000
35
3000
70
3000
373
120
24483
CUARTO DE SERVICIOS
COCINA
SALA + COMEDOR
DESCRIPCIN
P.I.(W)
1 lmpara
35
TV de 21
120
Una radio
40
Mini componente
110
2 lmparas
70
Refrigeradora
350
Horno microondas
1200
Licuadora
450
3500
Olla arrocera
1000
Extractor de jugo
100
Radio
100
Intercomunicador
50
105
TV de 29
140
Radio
100
Reproductor DVD
200
Equipo de msica
80
Ventilador
100
Telfono
50
3000
40
21
PASILLO COCINA
PASILLO SALA
DORMITORIO 1
DORMITORIO 2
ESTUDIO
SSHH
CURTO
SERVICIOS
1 lmparas
35
2 lmparas
70
4 salida de artefactos
400
1 lmparas
35
TV de 29
140
Reproductor DVD
200
Radio
40
Plancha
1000
1 lmparas
35
TV de 29
140
Reproductor DVD
200
Radio
40
Plancha
1000
1 lmparas
45
Una computadora
140
Impresora lser
200
Ventilador de pie
40
DE 1 lmparas
ducha elctrica
SSHH
PASILLO
COMEDOR
SSHH DORMITORIO 2
GRADAS O ESCALERAS
35
3000
35
3000
1 lmparas
35
ducha elctrica
3000
2 LAMPARAS
70
23875
COCINA
SALA + COMEDOR
DESCRIPCIN
1 lmpara
TV de 21
Una radio
Mini componente
2 lmparas
Refrigeradora
Horno microondas
Licuadora
Cocina elctrica de 3 hornilla
Olla arrocera
Extractor de jugo
Radio
Intercomunicador
6 lmparas por cada nivel
22
P.I.(W)
35
120
40
110
70
350
1200
450
3500
1000
100
100
50
105
TV de 29
Radio
Reproductor DVD
Equipo de msica
Ventilador
Telfono
Una ducha elctrica
una salida de artefacto adicional
PASILLO COCINA
1 lmparas
2 lmparas
PASILLO SALA
4 salida de artefactos
1 lmparas
TV de 29
DORMITORIO 1
Reproductor DVD
Radio
Plancha
1 lmparas
TV de 29
DORMITORIO 2
Reproductor DVD
Radio
Plancha
1 lmparas
Una computadora
ESTUDIO
Impresora lser
Ventilador de pie
SSHH
CURTO
DE 1 lmparas
ducha elctrica
SERVICIOS
SSHH
PASILLO
+ 1 lmparas por cada SSHH
ducha elctrica
COMEDOR
1 lmparas
SSHH DORMITORIO 2
ducha elctrica
GRADAS O ESCALERAS
2 LAMPARAS
POTENCIA TOTAL INSTALADA
140
100
200
80
100
50
3000
40
35
70
400
35
140
200
40
1000
35
140
200
40
1000
45
140
200
40
35
3000
35
3000
35
3000
70
23875
CARGADAS DE CALEFACICION
Aire acondicionado de 4000W
4000
Olla arrocera + Horno microondas
4*2200
CARGAS DE COCINA ELECTRICA
COCINA ELECTRICA 14000W
12000
2000
CARGAS DE CALENTADORES DE AGUA
Calentador de agua para bao
2500
CURQUIER CARGAADICIONAL > 1500W
Plancha elctrica 3*1000
3000
Olla arrocera + microondas
2200
CUALQUIER CARGA ADICIONAL <= 1500W
5 TVs
680
Equipo de msica
80
6 radios de msica
360
Mini componente
110
4 reproductor de DVD
800
4 computadoras
1600
4 impresoras
600
SUB TOTAL
4230
Iluminacin de jardines, azotea y 280
pasillos
Electro bomba
373
Refrigeradora
350
Licuadora
450
Extractor de jugo
100
Intercomunicador
50
4 ventiladores
300
Telfono
50
SUB TOTAL
1953
TOTAL
1
0.25
4000
2200
0.5
1
6000
800
2500
1
1
3000
2200
0.25
1057.5
1953
29010.5
NIVEL
PRIMER
D.M.(W)
995
1340
5700
2500
2500
2500
373
15908
M.D. Total en W
25%
K x V x Cos
Adicionndole un 25%, excepto para la bomba que esta accionado por motor elctrico
que en este caso se adiciono un 25% de la corriente de plena carga.
Posteriormente con esta corriente se har la eleccin del conductor y el dispositivo de
proteccin.
Donde:
I: Corriente a transmitir por el conductor alimentador en Amperios.
M.D. Total: Mxima demanda total hallada en Watts.
V: Tensin de servicio en Voltios (V=220 v).
K: Factor que depende si el suministro es monofsico o trifsico as:
Para monofsico : K 1
Para trifasico
Cos
Cos
CONDUCTOR :
:
:
:
K 3
para el tablero gerneral (Cos 0.9)
para el tablero TD-1 al TD-4 (Cos 0.9)
CONDUCTOS DE TUBERA:
En este caso se utilizar dos tipos tuberas, segn el tipo de cableado, adems de la
funcin que esta deber de cumplir en la instalacin: Tubera PVC SAP (Standard
Americano Pesado), Sern utilizados para todas las instalaciones para una mejor
proteccin a contactos mecnicos.
b) CALCULO DE LA MXIMA CORRIENTE, ELECCIN DE LA SECCIN DEL
CONDUCTOR, DISPOSITIVO DE PROTECCIN Y CONDUCTOS DE TUBERA.
Dispositiv
o de
protecci
n
Dimetr
conduct (interrupt
o del
D.M.
Circuito
Imax(A)
2
(W)
or(mm )
or
conducto
automtic
(mm)
o termo
magntico
)
Alimentador al TG
29010.5
183.14
70
200A
55
TG al TD 1 primera
15908
planta
90.386
25
90A
25
TG al TD 2 segunda
9730
planta
55.284
25
60A
25
TG al TD 3 tercera
9730
planta
55.284
2.5
60A
25
TG al TD 4
planta
55.284
2.5
60A
25
cuarta
9730
Dentro del este proyecto se ha tratado siempre con mucho cuidado la ubicacin de los
interruptores que sirven nica y exclusivamente para energizar y desenergizar las lmparas
incandescentes o fluorescentes y existen diferentes tipos de toma corrientes e interruptores
como son:
Se instalan juntas a las puertas de ingreso para el encendido de diferentes ambientes a iluminar
y se deben instalar de tal manera que uno puede encenderlas sin esfuerzo alguno en la
oscuridad. Se instalaran a 1,25m del piso. La cantidad necesaria de interruptores y sus
precios se muestran ms adelante.
4.7. OTRAS INSTALACIONES:
INTERCOMUNICADOR.
En este proyecto se ha visto necesario proyectar este sistema para la vivienda unifamiliar.
Este intercomunicador debe estar ubicado en la fachada principal de forma visible de tal
manera que cualquier individuo lo puede utilizar a la correspondiente llamada sonora.
ELECTROBOMBA.
Una electrobomba para la cisterna, sobre todo para llevar agua al 4to piso deber ser
segn indique el plano y de acuerdo al siguiente detalle:
agua limpia
1.2
20
1 x 1
Ejecucin Metalrgica
Caja:
Impulsor:
Segn tablas del CNE la alimentacin ser 230V y con 2 Amp. A plena carga.
Ejecucin Metalrgica
Caja:
Impulsor:
5. CIRCUITOS DE ALUMBRADO:
5.1 REGLA DEL ALUMBRADO:
Primer Paso: Llvese un conductor (neutro) a toda salida de luz y fuerza, excepto aquellas
controladas por interruptores bipolares.
Segundo Paso: Llvese el otro conductor (vivo) a los interruptores y salida de fuerza no
controlada (tomacorrientes), cuando se requieran en las no controladas.
Tercer Paso: En caso de existir interruptores de 3 vas, se llevar este conductor vivo, slo
a uno de los dos interruptores de conmutacin que integran cada sistema de encendido.
Este conducto no ir al interruptor de cuatro vas.
5.2. CADA DE TENSIN:
V K I
L
cos
S
Donde:
K=2, dimensin monofsica.
I: corriente.
: V 0.0175 mm2 :resistividad.
L: longitud.
S: seccin.
Cos=0.9, factor de potencia.
a) Cada de tensin para la primera planta:
circuito
Imax
(A)
Conducto
r (mm2)
L(m)
aprox.
Alimentador al TG
183.14
70
Alumbrado del TD 1
5.99747475
2.5
15
Tomacorriente del TD 1
10.479798
2.5
12
35.9848485
10
0.4
18.9393939
2.5
Electrobomba del TD 1
6.125
2.5
5.5
28
V
(V)
0.35113636
1.2594697
1.76060606
0.05037879
2.12121212
0.471625
2.5
2.5
5
1.32575757
4.5
1.19318182
L(m)
Aprox.
5.99747475
2.5
15
10.479798
2.5
12
35.9848485
10
0.4
18.9393939
2.5
2.5
2.5
Imax
(A)
circuito
Alumbrado del TD 2,3,4
Tomacorriente del TD 2,3,4
Cocina elctrica del TD 2,3,4
Ducha elctrica del TD 2,3,4
V
(V)
1.2594697
1.7606060
6
0.0503787
9
2.1212121
2
1.3257575
7
4.5
1.1931818
2
Como se puede ver de los resultados se puede decir que la cada de tensin que provocara
los conductores cumple la regla que se especifican en el C.N.E.
Que es como mximo un 2.5% que es equivalente a un 5.5V de 220V.
6. PUESTA A TIERRA:
Por puesta a tierra de proteccin se entiende la conexin de determinados elementos de una
instalacin elctrica con el potencial de tierra, asegurando la actuacin de los elementos de
proteccin y evitando tensiones de contacto peligrosas para las personas. La instalacin de la
puesta a tierra se logra, entre otras alternativas, mediante el empleo de electrodos enterrados
cuyas caractersticas dependen de aspectos como la calidad del suelo, parmetros elctricos del
sistema y la superficie de terreno disponible. Es importante mencionar que para puesta a tierra
de proteccin NO deben ser utilizados las caeras de cobre de la vivienda. Para mayores
antecedentes refirase a la norma antes indicada.
29
Es por eso que uno siempre se encuentra con tres conductores al momento de arreglar un
enchufe o instalar una lmpara, ya que los primeros dos corresponden a fase (energizada) y
neutro, y el tercer conductor es el de la puesta a tierra de proteccin. Si por ejemplo en la
instalacin de una mquina lavadora no se hubiese instalado este tercer conductor, o si la puesta
a tierra estuviese mal hecha, entonces en caso que ocurre una falla al interior de la mquina
puede que un conductor energizado haga contacto con la carcasa metlica de la lavadora
dejndola a una tensin peligrosa, sin que una persona lo note. Sin embargo, al contar con una
adecuada instalacin de puesta a tierra de proteccin, la carcasa estar puesta al potencial de
tierra, por lo que en el momento de contacto del conductor energizado con la carcasa se
producira un cortocircuito y actuarn las protecciones correspondientes.
Se instalar una puesta a tierra en el contenido por una barra (electrodo) de cobre o tubo de
fierro galvanizado, ste ltimo es galvanizado para protegido de la corrosin.
Esta tierra est constituida por tierra cernida hasta llegar a una altura de 2,40m, luego se rellena
con sulfato de magnesio hasta una altura de 20cm como se indica en el siguiente plano de
instalaciones elctricas. (LOS DATOS CON MAS DETALLE ESTAN EN LOS PLANOS Y
ANEXOS LAMINA IE-2
7. ELEMENTOS DE PROTECCIN:
Existen varios tipos de protecciones diferentes, por lo que a continuacin se explican los
dispositivos ms importantes utilizados para lograr continuidad en el servicio elctrico y
seguridad para las personas: Para nuestro proyecto se usaran fusibles de conexin trmica
Fusibles (Protecciones trmicas)
Estos dispositivos interrumpen un circuito elctrico debido a que una sobre corriente quema un
conductor ubicado en el interior, por lo que deben ser reemplazados despus de cada actuacin
para poder restablecer el circuito.
Interruptor diferencial
El interruptor diferencial, destinado a la proteccin contra los contactos indirectos, se instala en
el tablero elctrico despus del interruptor general del empalme. Si ocurre un cortocircuito en
algn aparato, se crea un desequilibrio entre la corriente que entra al aparato y la que sale del
mismo. Lo mismo ocurre si una persona toca una parte energizada de la instalacin elctrica.
En ambos casos, los interruptores diferenciales intervienen abriendo el circuito.
Interruptor termo magntico
Despus del interruptor diferencial se colocan los interruptores termo magnticos. Estos
interruptores cuentan con un sistema magntico de respuesta rpida ante sobre corrientes
abruptas, y una proteccin trmica basada en un bimetal que desconecta ante sobre corrientes
de ocurrencia ms lenta. En una instalacin domiciliaria se recomienda instalar uno de estos
interruptores para cada sub-circuito de la instalacin.
8. METRADO Y PRESUPUESTO:
8.1. DESARROLLO DEL METRADO:
30
DESCRIPCIN
METRADO
unidad
1.00
DUCTOS
31
Cantida
d
COSTOS
Precio
unitario
(S/.)
Total
(S/.)
1.05
1.06
1.07
1.08
2.00
CONDUCTORES
2.01
2.02
2.03
2.04
2.05
2.06
3.00
1.01
1.02
1.03
1.04
3.01
3.02
3.03
3.04
3.05
3.06
3.07
4.00
4.01
4.02
4.03
4.04
4.05
4.06
15mm de
25mm de
35mm de
55mm de
32
Pza.
156
936
Pza.
10
60
Pza.
30
Pza.
6.5
13
Pza.
Pza.
Pza.
Pza.
100
100
78
100
1.5
1.5
1.2
1.2
150
150
93.6
120
m
m
m
m
m
m
450
15
6
25
15
5
0.8
1.2
3.5
7.5
10
15
360
18
21
187.5
150
75
Pza.
68
47
3196
Pza.
Pza.
Pza.
Pza.
Pza.
Pza.
9
30
4
66
9
9
15
2.5
3.5
2.5
14
14
135
75
14
165
126
126
Jgo.
550
550
Jgo.
625
625
Jgo.
600
600
Jgo.
400
1600
Jgo.
550
550
Jgo.
400
400
4.07
5.00
5.01
6.00
6.01
6.02
6.03
6.04
6.05
TOTAL
600
600
600
2400
800
S/. 14 326.1
9. CONCLUSIONES:
Las luminarias elegidas deben ir de acuerdo a cada ambiente, por ejemplo para nuestro
caso, usamos luminarias de diferentes formas y potencias. Para una buena iluminacin de
cada ambiente.
La puesta a tierra y los circuitos de proteccin son muy importantes, no solo para proteger
a los aparatos y electrodomsticos, sino para proteger nuestras vidas y de nuestra familia.
33
Los tomacorrientes, los interruptores y los conductores, deben de ser de ms amperaje para
poder soportar por lo menos todas las cargas posibles encendidas al mismo tiempo, si se
diera el caso.
Aprendemos a utilizar las reglas y normas del cdigo nacional de electricidad.
La parte del los procedimientos para hallar el metrado, se deber considerar cada distancia
de los codos y uniones, no solo el largo de los tubos. Adems de aumentar cierta longitud
en la salida.
10. BIBLIOGRAFA:
Cdigo Nacional de Electricidad utilizacin que entro en vigencia el 1 de julio del 2006.
Diseo de instalaciones elctricas en residencias ( Mario Germn Rodrguez Macedo)
Editor WH
Montaje y diseo de instalaciones, elctricas interiores en edificaciones (ING. Pedro
Castillo Parisaca).
Pagina WEB ( www.Ministeriosenergia.com.pe)
Catlogos varios de proveedores de materiales elctricos.
34
11. ANEXOS:
Se presenta 5 planos: el primer plano nos muestra la arquitectura de los cuatro niveles, en el
segundo plano se muestra la elevacin principal, el corte longitudinal y el corte transversal. En
el tercer plano se muestra las instalaciones elctricas primer nivel y las instalaciones elctricas
segundo, tercero y cuarto nivel, por ltimo se presenta el plano de puesta a tierra y la
instalacin en la azotea.
35