Three-phase pad-mounted
compartmental type transformer
General
At Eatons Cooper Power Systems, we are
constantly striving to introduce new innovations
to the transformer industry, bringing you the
highest quality, most reliable transformers. Eatons
Cooper Power Systems Transformer Products
are ISO 9001 compliant, emphasizing process
improvement in all phases of design, manufacture,
and testing. In order to drive this innovation, we
have invested both time and money in the Thomas
A. Edison Technical Center, our premier research
facility in Franksville, Wisconsin. Headquarters
for the Systems Engineering Group of Eatons
Cooper Power Systems, such revolutionary
products as distribution-class UltraSIL
Polymer-Housed Evolution surge arresters and
EnvirotempFR3 fluid have been developed at
our Franksville lab.
Bay-O-Net fusing
Drip shield
Nameplate
laser-scribed anodized aluminum
LOW-VOLTAGE
BUSHING
Low-voltage
molded epoxy
bushings with
NEMA spades
LOWVOLTAGE
BUSHING
SUPPORT
LOADBREAK SWITCH
HIGH-VOLTAGE BUSHING
SILL
Suitable for skidding,
rolling, and jacking
Fluid Type
Coil Configuration
Size
45 12,000 kVA
Primary Voltage
2,400 46,000 V
Secondary Voltage
208Y/120 V to 14,400 V
Inverter/Rectifier Bridge
K-Factor (up to K-19)
Vacuum Fault Interrupter (VFI)
UL Listed & Labeled and Classified
Specialty Designs
www.cooperpower.com
Removeable cabinet
walls
Transformers are available in the standard ratings and configurations shown or can be customized to meet specific needs.
Decibels (dB)
45-500
56
501-700
57
701-1000
58
1001-1500
60
1501-2000
61
2001-2500
62
2501-3000
63
3001-4000
64
4001-5000
65
5001-6000
66
6001-7500
67
7501-12000
68
kV BIL
Distribution
1.2
30
10
2.5
45
15
60
19
8.7
75
26
95
34
125
40
25
150
50
125
40
34.5
150
70
46
200
95
15
25 (grd Y Only)
Standard
Optional
65 C
55 C, 55/65 C, 75 C
40 C
50 C
30 C
40 C
80 C
65 C
www.cooperpower.com
A*
H
F-3
3.5"
I-3
E
F
PAD DIMENSIONS
CABINET/TANK DIMENSIONS
Gallons of
Fluid
Approx. Total
Weight (lbs.)
45
75
112.5
150
225
300
500
750
1000
1500
2000
2500
3000
3750
5000
7500
50
50
50
50
50
50
50
64
64
73
73
73
73
84
84
94
110
115
120
125
140
160
190
270
350
410
490
530
620
660
930
1,580
2,100
2,250
2,350
2,700
3,150
3,650
4,650
6,500
8,200
10,300
12,500
14,500
16,700
19,300
25,000
41,900
kVA Rating
Gallons of
Fluid
Approx. Total
Weight (lbs.)
45
75
112.5
150
225
300
500
750
1000
1500
2000
2500
3000
3750
5000
7500
50
50
50
50
50
50
50
64
64
73
73
73
73
84
84
94
110
115
115
120
140
160
200
255
300
410
420
500
720
800
850
1,620
2,100
2,350
2,500
2,700
3,250
3,800
4,800
6,500
7,800
10,300
11,600
14,000
18,700
20,500
25,000
46,900
68
68
68
68
72
72
89
89
89
89
72
72
84
85
96
102
39
39
49
49
51
51
53
57
59
86
87
99
99
108
108
122
42
42
42
42
42
42
42
42
42
42
42
42
46
47
48
54
26
26
26
26
30
30
30
30
30
30
30
30
37
38
48
48
68
68
68
68
72
72
72
72
72
72
72
72
84
85
96
102
72
72
72
72
76
76
93
93
93
93
76
76
88
88
100
100
43
43
53
53
55
55
57
61
63
90
91
103
103
112
112
126
20
20
20
20
20
20
20
20
20
24
24
24
24
24
24
24
1 Weights, gallons of fluid, and dimensions are for reference only and not for construction. Please contact Eatons Cooper Power Systems for exact dimensions.
* Add 9" for Bay-O-Net fusing.
64
64
64
64
64
64
81
89
89
89
72
72
84
85
96
102
34
34
34
34
34
34
34
42
42
42
42
42
46
47
48
54
30
30
30
30
30
30
30
30
30
30
30
30
37
38
48
48
64
64
64
64
64
64
64
72
72
72
72
72
84
85
96
102
69
69
69
69
73
75
85
93
93
93
76
76
88
88
100
100
43
43
53
53
55
55
57
61
63
90
91
103
103
112
112
126
20
20
20
20
20
20
20
20
20
24
24
24
24
24
24
24
Weights, gallons of fluid, and dimensions are for reference only and not for construction. Please contact Eatons Cooper Power Systems for exact dimensions.
39
39
49
49
51
51
53
57
59
86
87
99
99
108
108
122
www.cooperpower.com
Standard features
Tank/cabinet features
Parking Stands
Valves/plugs
Nameplate
www.cooperpower.com
Optional features
Overcurrent protection
Cartridge fusing in series with a partial range under-oil ELSP current limiting fuse (above 23 kV)
Fuse/switch interlock
Tank/cabinet features
Valves/plugs
Overvoltage protection
Kirk-Key provisions
Metering/fan/control
Nitrogen blanket
Metering Socket
NEMA 4 control box (optional stainless steel)
Special designs
UL Classified
Triplex
Fan Packages
High altitude
Testing
K-Factors
Step-up
Critical application
Modulation transformers
Switches
Delta-wye switch
Coatings (paint)
Nameplate
Ground connectors
www.cooperpower.com
Mr. Ouch
Bi-lingual warning
DOE compliant
Customer stenciling
Non-PCB decal
Construction
Core
The three-legged, step-lap mitered core construction is manufactured using a high-quality cutting machine. For maximum efficiency,
cores are precisely stacked, virtually eliminating gaps in the corner
joints.
Five-legged wound core or shell-type triplex designs are used for
wye-wye connected transformers, and other special transformer
designs.
Cores are manufactured with precision cut, burr-free, grain-oriented
silicon steel. Many grades of core steel are available for optimizing
core loss efficiency.
Coils
Pad-mounted transformers feature a rectangular coil configuration
with wire-wound, high-voltage primaries and sheet-wound
secondaries. The design minimizes axial stress developed by short
circuits and provides for magnetic balancing of tap connections.
Coils are wound using the highest quality winding machines providing exacting tension control and conductor placement for superior
short-circuit strength and maximum efficiency.
Extra mechanical strength is provided by diamond pattern, epoxycoated paper insulation, used throughout the coil, with additional
epoxy at heavy stress points. The diamond pattern distribution of the
epoxy and carefully arranged ducts, provide a network of passages
through which cooling fluid can freely circulate.
Tanks
Transformer tanks are designed for high strength and ease of
handling, installation, and maintenance. Tanks are welded using
precision-cut, hot rolled, pickled and oiled steel. They are sealed to
protect the insulating fluid and other internal components.
Tank finish
An advanced multi-stage finishing process exceeds IEEE Std
C57.12.28-2005 standards. The eight-stage pre-treatment process
assures coating adhesion and retards corrosion. It converts tank
surfaces to a nonmetallic, water insoluble iron phosphate coating.
The paint method consists of two distinct layers of paint. The first
is an epoxy primer (E-coat) layer which provides a barrier against
moisture, salt and corrosives. The two-component urethane final
coat seals and adds ultraviolet protection.
Vacuum processing
Transformers are dried and filled with filtered insulating fluid under
vacuum, while secondary windings are energized. Coils are heated
to drive out moisture, ensuring maximum penetration of fluid into
the coil insulation system.
Insulating fluid
Transformers from Eatons Cooper Power Systems are available
with electrical-grade mineral insulating oil or EnvirotempFR3
fluid. The highly refined fluids are tested and degassed to assure a
The VFI transformer combines a conventional distribution transformer from Eatons Cooper Power Systems with the proven Vacuum
Fault Interrupter (VFI). This combination provides both voltage transformation and transformer over current protection in one space saving and money saving package. The pad-mounted VFI transformer
protects the transformer and provides proper coordination with
upstream protective devices. When a transformer fault or overload
condition occurs, the VFI breaker trips and isolates the transformer.
The three-phase VFI breaker has independent single-phase initiation,
but is three-phase mechanically gang-tripped. A trip signal on any
phase will open all three phases. This feature eliminates single-phasing of three phase loads. It also enables the VFI breaker to be used
as a three-phase load break switch.
Due to the resettable characteristics of the VFI breaker, restoring
three-phase service is faster and easier.
The sealed visible break window and switch is an option that can
be installed to provide visible break contact. This feature provides
enhanced safety and allows an operator to see if the loadbreak
switch contacts are in an open or closed position before performing
maintenance.
www.cooperpower.com
Solar transformer
Reduction in footprint
www.cooperpower.com
Wind transformer
Eatons Cooper Power Systems is offering custom designs for
renewable energy power generation. Eatons Cooper Power
Systems manufactures Generator Step-Up (GSU) transformers for
installation at the base of every wind turbine. Additionally, grounding
transformers are available for wind power generation.
DOE efficiency
K-Factor transformer
Inverter/rectifier bridge
With a drastic increase in the use of ferromagnetic devices, arcing devices, and electric power converters, higher frequency loads
have increased significantly. This harmonic loading has the potential
to generate higher heat levels within a transformers windings and
leads by as much as 300%. Harmonic loading has the potential to
induce premature failure in standard-design distribution transformers.
Eatons Cooper Power Systems complements its range of applications for transformers by offering dual winding designs. These
designs are intended for connection to 12-pulse rectifier bridges.
Modulation transformer
Bundled with an Outboard Modulation Unit (OMU) and a Control
and Receiving Unit (CRU), a Modulation Transformer Unit (MTU) is
designed to remotely achieve two way communication.
The use of an MTU reduces travel time and expense versus traditional meter reading performed by high voltage electricians.
Additionally, with MTU it is possible to manage and evaluate energy
consumption data, providing reduced metering costs and fewer tenant complaints.
An MTU utilizes existing utility infrastructure, therefore eliminating
the need to engineer and construct a dedicated communication network.
Product attributes
To set us apart from other transformer manufactures, Eatons Cooper
Power Systems includes the following guarantees with every threephase pad-mounted transformer.
Testing
Eatons Cooper Power Systems performs routing testing on each
transformer manufactured including the following tests:
Induced Potential: 3.46 times normal plus 1000 volts for reduced
neutral designs.
10
www.cooperpower.com
www.cooperpower.com
11
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Eatons Cooper Power Systems Business
2300 Badger Drive
Waukesha, WI 53188
United States
Cooperpower.com
2013 Eaton
All Rights Reserved
Printed in USA
Publication No. 210-12
August 2013
3 - P H T R A NSF OR MER L E SS
S T R ING IN V ER T ER S
PVI 14TL
PVI 20TL
PVI 23TL
PVI 28TL
PVI 36TL
features
600 or 1000 VDC
Best-in-class efficiency
Touch-safe fuses
Quick and easy installation
Dual MPP tracking zones
Wide MPPT range
Lightweight, compact
design
Modbus communications
User-interactive LCD
Solectria Renewables PVI 14TL, PVI 20TL, PVI 23TL, PVI 28TL, and PVI 36TL are
DC arc-fault protection
options
Web-based monitoring
Shade cover
reliability and uptime. They also come with a standard 10 year warranty with options
for 15 and 20 years. Options include web-based monitoring, shade cover, DC/AC
DC combiners bypass
PVI 14TL
PVI 20TL
PVI 23TL
PVI 28TL
PVI 36TL
DC Input
Absolute Maximum Open Circuit Voltage
600 VDC
1000 VDC
180-580 VDC
260-580 VDC
300-540 VDC
300-550 VDC
300-900 VDC
480-800 VDC
MPP Trackers
280-950 VDC
500-800 VDC
540-800 VDC
60 A per MPPT
(120 A)
9.5 kW
13.5 kW
15.5 kW
19 kW
27 kW
Strike Voltage
300 V
330 V
AC Output
Nominal Output Voltage
-12%/+10%
14 kW
20 kW
23 kW
28 kW
36 kW
39 A
24 A
27.7 A
33.7 A
43 A
0A
60 Hz
Power Factor
57-63 Hz
Unity, >0.99
( 0.9 adjustable)
Unity, >0.99
( 0.8 adjustable)
< 3%
3+/N/GND
Efficiency
Peak Efficiency
96.9%
97.4%
CEC Efficiency
96.0%
97.0%
98.0%
4W
2W
1W
Tare Loss
98.6%
98.5%
15 or 30 A
(30 A only for
combined inputs)
Temperature
-13F to +140F (-25C to +60C)
Derating occurs over +50C
-58F to +158F
(-50C to +70C)
0-95%
Operating Altitude
Data Monitoring
Optional SolrenView Web-based Monitoring
Integrated
External
Testing Agency
ETL
Warranty
Standard
10 year
Optional
Enclosure
dBA (Decibel) Rating
< 50 dBA @ 1m
AC/DC Disconnect
Dimensions (H x W x D)
Weight
Standard, fully-integrated
41.6 in. x 21.4 in. x 8.5 in.
(1057 mm x 543 mm x 216 mm)
141 lbs (64 kg)
Enclosure Rating
Type 4
Enclosure Finish
Copyright Solectria Renewables, LLC. All information subject to change without notice. January 2015 DOCR-070252-J
SPECIFICATIONS
Solidlock
Fixed Knot
Are you looking for an agricultural fence thats strong, virtually maintenance free, and comes in sizes suited for practically
all animals and applications?
Look no further than Solidlock.
Our fixed knot design combined with high tensile wire makes Solidlock the strongest woven wire fence you can buy.
This design locks the line wire and stay wire together, giving you the strength you require. Plus Solidlocks use of high
tensile wire and solid vertical stays means next to no maintenance. You can spend less time worrying about your fence
- whether you want to keep animals in or out.
Theres a Solidlock fence option to fit virtually any application you require. Our fence is available in varieties ranging
from 42 inches to 120 inches tall. We have larger staggered openings or smaller 3 x 3 inch openings for horse applications.
Solidlock fence is available in Class 3 (heavy coat) galvanized for long life. You can also get Solidlock with Bezinal +
Paint advanced coating. Choose either a black or green finish and enjoy the benefits of a product that will last four to
six times longer than a standard Class 1 fence.
23/120
8
Solidlock Game
Solidlock Cattle
Solidlock Horse
available in 3 stay
8
8
20/96
17/96
7
7
7
17/75
7
7
10/60
7
15/61
15/61
4
4
3
3
3
3
3
3
4
4
6
6
4
4
3
3
3
3
3
3
13/48
9/49
13/48
6
8/42
6
6
5
5
6
6
6
5
5
4
4
3
3
3
3
3
3
Height
Vertical
Stay
Spacing
Roll
Length
Top and
Bottom Wire
Diameter
Main Wire
Diameter
118218
118257
118248
118269
118229
118280
118271
118288
118376
118241
118371
118318
1060 6
1060 12
1561 6
1775 6
1775 12
1796 6
2096 3
2096 6
2096 6
2096 12
2096 12
23120 6
60
60
61
75
75
96
96
96
96
96
96
120
6
12
6
6
12
6
3
6
6
12
12
6
330
660
330
330
330
330
165
330
500
330
660
330
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
210 lbs
294 lbs
279 lbs
327 lbs
236 lbs
355 lbs
340 lbs
396 lbs
601 lbs
264 lbs
564 lbs
492 lbs
Class 3
Class 3
Class 3
Class 3
Class 3
Class 3
Class 3
Class 3
Class 3
Class 3
Class 3
Class 3
136692
136261
2096 6
2096 6
96
96
6
6
330
330
12.5g
12.5g
12.5g
12.5g
396 lbs
396 lbs
Green
Black
Height
Vertical
Stay
Spacing
Roll
Length
Top and
Bottom Wire
Diameter
Main Wire
Diameter
42
42
42
49
49
49
48
48
6
12
12
6
12
12
6
12
330
330
660
330
330
660
330
330
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
Height
Vertical
Stay
Spacing
Roll
Length
Top and
Bottom Wire
Diameter
Main Wire
Diameter
48
48
61
61
3
3
3
3
100
200
100
200
Part
Number
Roll
Weight
Finish
118185
118144
118221
118199
118162
118239
118226
118310
Fence
Design
842 - 6
842 - 12
842 - 12
949 - 6
949 - 12
949 - 12
1348 - 6
1348 - 12
Roll
Weight
157 lbs
110 lbs
220 lbs
182 lbs
129 lbs
257 lbs
234 lbs
176 lbs
Finish
Class 3
Class 3
Class 3
Class 3
Class 3
Class 3
Class 3
Class 3
118150
118225
118174
118249
Fence
Design
1348 - 3
1348 - 3
1561 - 3
1561 - 3
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
12.5g
Roll
Weight
117 lbs
233 lbs
140 lbs
280 lbs
Finish
Class 3
Class 3
Class 3
Class 3
141324
137452
137453
Fence
Design
1048 - 3
1048 - 12
1048 - 12
Height
48
48
48
Vertical
Stay
Spacing
3
12
12
Roll
Length
165
330
660
Top and
Bottom Wire
Diameter
12.5g
12.5g
12.5g
Main Wire
Diameter
14g
14g
14g
Roll
Weight
109 lbs
105 lbs
210 lbs
Finish
Class 3
Class 3
Class 3
NEW TECHNOLOGY
Reduces cell series resistance
Reduces stress between cell interconnectors
Improves module conversion efficiency
Improves product reliability
KEY FEATURES
insurance-backed warranty
non-cancellable, immediate warranty insurance
linear power output warranty
product warranty on materials
and workmanship
MANAGEMENT SYSTEM CERTIFICATES*
ISO 9001: 2008 / Quality management system
PRODUCT CERTIFICATES*
IEC 61215 / IEC 61730: VDE/ MCS/ CE/ JET /SII/ KEMCO/ CEC AU/CQC/ INMETRO
your local Canadian Solar sales representative for the specific certificates applicable to
the products in the region in which the products are to be used.
40
10
1954
1400
1155
Grounding
hole
25
A
10
11
8-11 7 -
Mounting
hole
Mounting Hole
5 10 15 20 25 30 35 40 45
V
5 10 15 20 25 30 35 40 45 50
7
R
11
40
932
982
310P
315P
320P
310 W
315W
320 W
36.4 V
36.6V
36.8 V
8.52 A
8.61A
8.69 A
44.9 V
45.1V
45.3 V
9.08 A
9.18A
9.26 A
16.16% 16.42 % 16.68 %
-40C ~ +85C
1000 V (IEC)or1000V ( UL)
TYPE 1 (UL 1703) or
CLASS C (IEC 61730)
15 A
Class A
0~+5W
310P
225 W
33.2 V
6.77 A
41.3 V
7.36 A
315P
228 W
33.4 V
6.84 A
41.5 V
7.44 A
320P
232 W
33.6 V
6.91 A
41.6 V
7.50 A
1000 W/m2
800 W/m2
600 W/m2
400 W/m2
5C
25C
45C
65C
TEMPERATURE CHARACTERISTICS
Specification
Temperature Coecient (Pmax)
Temperature Coecient (Voc)
Temperature Coecient (Isc)
Nominal Operating Cell Temperature
PARTNER SECTION
CANADIAN SOLAR INC. July 2015. All rights reserved, PV Module Product Datasheet I V5.2_EN
Data
-0.43% / C
-0.34% / C
0.065% / C
452C
NEXTracker 120
May 2015
Control System:
Communications:
Module Compatability:
Framed or frameless c-Si and thin film modules; portrait and landscape mounting options
80 72-cell c-Si modules mounted in portrait/ 210 CdTe modules mounted in landscape
DC Capacity:
100mph/161kph, 3 second gust with 30psf snow load per ASCE 7-10, 0; configurable for
higher wind speeds and snow loads
Wind Protection:
Torsional Limiter:
Rotational Range:
Drive System:
Power Consumption:
Foundation Types:
Compatible with all major foundation types (driven pier, concrete foundation, ground screw)
Principal Materials:
Installation Method:
Grounding Method:
Compliance:
Warranty:
Typical Dimensions:
Typical 72-cell c-Si configuration: 85m row with 80 modules mounted in portrait:
6.4ft
[1.96m]
6.8ft
[2.08m]
4.0ft
[1.22m]
60
3.3ft
[1.00m]
1.2ft