You are on page 1of 44

INDUSTRIAL AND MINING

GRADE CABLES
NORTH AMERICA FACTORY INVENTORY

TELE-FONIKA CABLE AMERICAS


TELE-FONIKA CABLE AMERICAS (TFCA) is a U.S. corporation with offices and main warehouse located in
Bolingbrook, Illinois. TFCA is a wholly owned subsidiary of Tele-Fonika Kable (TFK) with responsibility for North and
South American markets. TFK, one of the largest manufacturers of wire and cable in Europe, is a fully integrated
manufacturer, recognized by the industry as a world-class producer of wire and cable products. The company
specializes in products for heavy industry, mining, and utility applications. The company is a recognized global
supplier of Portable Power Cords, Mining Cable, and Medium and High Voltage Utility Cables.
TF Kable has been active in the Americas since 1987, providing products through a network of authorized
distributors, international agents, and domestic sales representatives.
TF Kable markets include utility power distribution, alternative energy, entertainment, portable power, mass
transit, military, and a number of other commercial applications.
All products appearing in this catalogue are standard stocked items.
This product catalogue highlights the specific wire and cable which is the strength and core of TF Kables production
portfolio. The catalogue provides technical details of all items, subject to availability, that are stocked at a number
of facilities located across North America with the ability to ship within 24 hours. TF Kable is able to make and offer
many other products and sizes not included in this catalogue but they are not standard stocking items.

Your one-stop source for industrial and mining cables.


From manufacturing to distribution,
TF Kable is todays premier cable provider.

555 Remington Blvd, Bolingbrook, IL 60440, U.S.A.


phone (630) 406-9000 | fax (630) 406-6574
www.tfcable.com

TELE-FONIKA KABLE
TELE-FONIKA KABLE SA, a privately held wire and cable manufacturer headquartered in Krakow,
Poland, is one of the largest wire and cable companies in the world. TF operates 8 plants in Central
and Eastern Europe with a distribution network stretching 90 countries. Formed through a series of
acquisitions and mergers, TFK has developed world-class technology centers of excellence with state
of the art manufacturing operations. Founded in 1992, TF grew rapidly and the operations today are
a result of internal development projects supported by strategic investments.
TF is the leading medium and high voltage cable manufacturer in Europe with significant market share
in rubber insulated portable power cables used by HEAVY INDUSTRY & MINING. Additionally, the
company manufactures products for the TELECOMMUNICATION, SHIP BUILDING, ELECTRONIC
and ENERGY sectors.
All manufacturing facilities are ISO 9001, ISO 2000, and ISO 14001 certified. All products
are manufactured to public, utility and industrial standards including ICEA, IEEE, and ASTM.
Tele-Fonika has over 400 individual certificates issued by more than 30 governing bodies
which include UL, CSA, MSHA, SABS, VDE, CE, etc.

TABLE OF CONTENTS
INDUSTRIAL GRADE PORTABLE POWER 2000V
W 1/C RHH/RHW-2 2000V Extra Flex 90C UL, C(UL), MSHA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
W 2 /C 2000V 90C - UL, C(UL), MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
W 3 /C 2000V 90C - UL, C(UL), MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
W 4 /C 2000V 90C - UL, C(UL), MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
W 5 /C & 6 /C 2000V 90C - UL, C(UL), MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
G-GC 3/C 2000V 2000V 90C - UL, C(UL), MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
G 4/C 2000V 90C - UL ,C(UL), MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
DLO / RHH / RHW-2 / 2000V / RW90 1000V 90C - UL, CSA, MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . 8
DLO / RHH / RHW-2 / 2000V / RW90 1000V 90C - UL, CSA, MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . 9
MINING GRADE POWER 2000V - 15000V
W 4/C 2000V Mining Grade 90C - UL, C(UL), MSHA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
G-GC 3/C 2000V Mining Grade 90C - UL, C(UL), MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
G-GC 3/C 2000V Mining Grade 90C - UL, C(UL), MSHA (CSA Canada color code) . . . . . . . . . . . . . 12
MP-GC 3/C 5000V / 15000V - XLP / PVC Mining Grade 90C - MSHA (CSA available). . . . . . . . . . . 13
MP-GC 3/C 8000V / 15000V - EPR / CPE Mining Grade 90C - MSHA . . . . . . . . . . . . . . . . . . . . . . . 14
SHD-GC 3/C 2000V 90C - MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
SHD-GC 3/C 2000V 90C - CSA, MSHA (CSA Canada Color Code) . . . . . . . . . . . . . . . . . . . . . . . . . 16
SHD-GC 3/C 5000V 90C - MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
SHD-GC 3/C 5000V 90C - CSA, MSHA (CSA Canada Color Code). . . . . . . . . . . . . . . . . . . . . . . . . . 18
SHD-GC 3/C 8000V / 15000V 90C - MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
SHD-GC 3/C 8000V / 15000V 90C - CSA, MSHA (CSA Canada Color Code). . . . . . . . . . . . . . . . . . 20
PORTABLE CORD AND CONTROL 300V - 600V
SJOOW 300V Flextreme Portable Cord -40C +90C - UL, CSA, MSHA . . . . . . . . . . . . . . . . . . . . . . . 21
SOOW 600V Flextreme Portable Cord -40C +90C - UL, CSA, MSHA. . . . . . . . . . . . . . . . . . . . . . . . 22
SOOW 600V Power Cable -40C +90C - UL, CSA, MSHA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
SOOW 600V Power Cable -40C +90C - MSHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
SOOW 600V Controlflex Control Cable -40C +90C - UL, CSA, MSHA. . . . . . . . . . . . . . . . . . . . . . . . 25
SOOW 600V Controlflex Control Cable -40C +90C - UL, CSA, MSHA. . . . . . . . . . . . . . . . . . . . . . . . 26
SOOW 600V Super Flextreme Portable Cord -50C + 105C - UL, CSA, MSHA . . . . . . . . . . . . . . . . . 27
SOOW H07RN-F 600V Flextreme Portable Cord -40C + 90C - UL, CSA, MSHA, <HAR>. . . . . . . . . 28
SC Stage Lighting 600V 105C - UL, C(UL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
INDUSTRIAL GRADE POWER, WELDING, LIGHTING 600V
USE-2 RHH / RHW 600V 90C - UL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Arc Welding Cable 600V Zero Halogen 105C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Remote Drill Cord 600V -40C +90C - MSHA & Jumper Cable 15000V Utility Grade. . . . . . . . . . . . . 32
UTILITY GRADE
Grounding Cable 600V PVC Utility Grade & Grounding Cable 600V CPE Utility Grade . . . . . . . . . . 33
GENERAL INFORMATION
TF SAP INDEX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-37
Terms and Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
TELE-FONIKA CABLE SUPPLIES PRODUCTS ACCORDING TO:

MSHA

2000V W RHH/RHW-2
Portable Power Cable 90C UL C(UL) MSHA
Industrial Grade
SPECIFICATIONS & STANDARDS

ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B172, ASTM B 33, UL 44

CONSTRUCTION:

Conductors:

Separator:
Insulation:
Reinforcement:
Jacket:

Extra flexible strand bare copper (Standard Flex tin copper), B-172 and ICEA S-75-381/NEMA WC70
Tape separator between conductor and insulation
Ethylene-propylene rubber (EPR), ICEA S-95-658 sec.3.21, table 3-6
Nylon open braid applied over insulation
Black heavy duty CPE thermoset compound, ICEA S-75-381/NEMA WC70 sec 3.21, table 3-4

FEATURES

APPLICATION

- Portable power systems


- Other industrial applications

Super-excellent flexibility
Water resistant and flame retardant
Rated and flexible at 40C to +90C
Excellent impact and abrasion resistant
Ozone, sunlight, oil, grease, weather, chemical resistant

APPROVALS:

UL:
E207132 Oil Resistant; Oil Resistant Inners; Sunlight Resistant; 90C Wet or Dry
C(UL):
E207132 FT1; FT5; -40C +90C
MSHA: P-7K-268101

EXTRA FLEX
Part Number

W8-1X
W6-1X
W4-1X
W2-1X
W1-1X
W1/0-1X
W2/0-1X
W3/0-1X
W4/0-1X
W250-1X
W350-1X
W500-1X

Power Conductor
Size

Power Conductor
Stranding

Nominal Insulation
Thickness

AWG or MCM

No. of Wires

inches

mm

inches

mm

8 AWG
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 MCM
350 MCM
500 MCM

162/30
264/30
418/30
660/30
836/30
1056/30
1320/30
1672/30
2090/30
2496/30
3416/30
4880/30

0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.095
0.095
0.095

1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.41
2.41
2.41

0.441
0.511
0.564
0.651
0.729
0.751
0.800
0.856
0.981
1.001
1.133
1.255

11.2
12.9
14.3
16.5
18.5
19.0
20.3
21.7
24.9
25.4
28.8
31.9

Nominal O.D.

Approx. Weight
Ibs/1000 ft
145
200
255
375
475
530
650
750
970
1130
1420
1913

Ampacity (1) 30C


Ambient Temp.

kgs/km
216
298
379
558
707
789
967
1116
1444
1682
2116
2847

A
80
105
140
190
220
260
300
350
405
455
570
700

(1) Ampacity - Free air measured. Based on continuous duty at 90C conductor temperature per 2011 NEC Table 400.5(A)(2)

STANDARD PRINT LEGEND:

TF CABLE (SIZE) TYPE W 2000V PORTABLE POWER CABLE RHH/RHW-2 90C SUN RES OIL RES 90C WET OR DRY (UL) E207132 C(UL) FT1
FT5 (-40C) P-7K-268101-MSHA

SPECIAL FACTORY OPTIONS:


Jacket:
MSHA:
Conductor:

Other colors available


P-7K-268077 (Neoprene)
Also available in Standard Flex tin copper stranding

Issue 7.0, July 2015

phone: 630-406-9000

www.tfcable.com

W 2000V

Portable Power Cable 90C UL C(UL) MSHA


Industrial Grade

SPECIFICATIONS & STANDARDS

ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B172, ASTM B 33, UL 44

CONSTRUCTION:

Conductors:

Separator:
Insulation:
Assembly:
Reinforcement:
Jacket:
Color Code:

Flexible strand tin copper, ASTM B-172 and ICEA S-75-381/NEMA WC58
Tape separator between the conductor and insulation
Ethylene-propylene rubber (EPR), ICEA S-75-381 sec 3.15, table 3-8
Conductors and rubber fillers cabled to form round core
Single faced rubber filled binder tape over insulation
Black heavy duty CPE thermoset compound, ICEA S-75-381 sec 3.4, table 3-4
ICEA S-75-381 sec 3.18; black, white

FEATURES

APPLICATIONS

- Portable power systems


- Other industrial applications
- Mining application where bare grounding conductors
are not required

Excellent flexibility
Water resistant and flame resistant
Rated and flexible at 40C to +90C
Excellent impact and abrasion resistant
Ozone sunlight oil, grease, weather, chemical resistant

APPROVALS:
UL:
C(UL):
MSHA:

E207132 Oil Resistant; Oil Resistant Inners; Sunlight Resistant; 90C Wet or Dry
E207132 - FT1; FT5; -40C +90C
P-7K-268101

2 CONDUCTOR
Part
Number

W8-2
W6-2
W4-2
W2-2

Power
Conductor
Size

Power
Conductor
Stranding

AWG or MCM

No. of Stranding

8 AWG
6 AWG
4 AWG
2 AWG

133 7x19
259 7x37
259 7x37
259 7x37

Nominal Insulation
Thickness

Nominal
O.D.

Ampacity (1)
30C
Ambient Temp.

Approx.
Weight

inches

mm

inches

mm

lbs/1000 ft

kgs/km

0.060
0.060
0.060
0.060

1.52
1.52
1.52
1.52

0.83
0.94
1.07
1.26

21.1
23.9
27.3
32.1

391
571
793
1142

581
849
1180
1699

74
99
130
174

(1) Ampacity - Free air measured. Based on continuous duty at 90C conductor temperature per 2011 NEC Table 400.5(A)(2)

STANDARD PRINT LEGEND:

TF CABLE (SIZE) TYPE W PORTABLE POWER CABLE 2000V 90C SUN RES OIL RES 90C WET OR DRY (UL) E207132 C(UL) FT1 FT5 (-40C)
P-7K-268101-MSHA

SPECIAL FACTORY OPTIONS:


Jacket:
MSHA:
CSA:

Other colors available


P-7K-268077 (Neoprene)
1523058 (LR 103932) FT1; FT5; 90C; (-40C) (Neoprene)

www.tfcable.com

phone: 630-406-9000

Issue 7.0, July 2015

Portable Power Cable 90C UL C(UL) MSHA


Industrial Grade

2000V w

SPECIFICATIONS & STANDARDS

ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B172, ASTM B 33, UL 44

CONSTRUCTION:

Conductors:

Separator:
Insulation:
Assembly:
Reinforcement:
Jacket:
Color Code:

Flexible strand tin copper, ASTM B-172 and ICEA S-75-381/NEMA WC58
Tape separator between the conductor and insulation
Ethylene-propylene rubber (EPR), ICEA S-75-381 sec 3.15, table 3-9
Conductors and rubber fillers cabled to form round core
Single faced rubber filled binder tape over insulation
Black heavy duty CPE thermoset compound, ICEA S-75-381 sec 3.4, table 3-4
ICEA S-75-381 sec 3.18; black, white, green

FEATURES

APPLICATIONS

- Portable power systems


- Other industrial applications
- Mining application where bare grounding conductors
are not required

Excellent flexibility
Water resistant and flame resistant
Rated and flexible at 40C to +90C
Excellent impact and abrasion resistant
Ozone sunlight oil, grease, weather, chemical resistant

APPROVALS:
UL:
C(UL):
MSHA:

E207132 Oil Resistant; Oil Resistant Inners; Sunlight Resistant; 90C Wet or Dry
E207132 - FT1; FT5; -40C +90C
P-7K-268101

3 CONDUCTOR
Part
Number

W8-3
W6-3
W4-3
W2-3
W1-3
W1/0-3
W2/0-3
W3/0-3
W4/0-3
W250-3
W350-3
W500-3

Power
Conductor
Size

Power
Conductor
Stranding

AWG or MCM

No. of Stranding

inches

mm

inches

mm

lbs/1000 ft

kgs/km

133 7x19
259 7x37
259 7x37
259 7x37
259 7x37
266 19x14
342 19x18
418 19x22
532 19x28
627 19x33
888 37x24
1221 37x33

0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.095
0.095
0.095

1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.41
2.41
2.41

0.91
1.01
1.05
1.32
1.51
1.63
1.73
1.85
1.99
2.39
2.66
2.98

23.1
25.7
26.5
33.6
38.4
41.4
44.0
47.0
50.6
60.7
67.5
75.8

541
715
1010
1405
1734
2030
2566
2885
3479
4368
5895
7820

805
1064
1503
2091
2581
3010
3818
4293
5177
6500
8772
11638

65
87
114
152
177
205
237
274
316
352
433
536

8 AWG
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 MCM
350 MCM
500 MCM

Nominal Insulation
Thickness

Nominal
O.D.

Ampacity (1)
30C
Ambient Temp.

Approx.
Weight

(1) Ampacity - Free air measured. Based on continuous duty at 90C conductor temperature per 2011 NEC Table 400.5(A)(2)

STANDARD PRINT LEGEND:

TF CABLE (SIZE) TYPE W PORTABLE POWER CABLE 2000V 90C SUN RES OIL RES 90C WET OR DRY (UL) E207132 C(UL) FT1 FT5 (-40C)
P-7K-268101-MSHA

SPECIAL FACTORY OPTIONS:


Jacket:
MSHA:
CSA:

Other colors available


P-7K-268077 (Neoprene)
1523058 (LR 103932) FT1; FT5; 90C; (-40C) (Neoprene)

Issue 7.0, July 2015

phone: 630-406-9000

www.tfcable.com

W 2000V
Portable Power Cable 90C UL C(UL) MSHA
Industrial Grade

SPECIFICATIONS & STANDARDS

ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B172, ASTM B 33, UL 44

CONSTRUCTION:

Conductors:

Separator:
Insulation:
Assembly:
Reinforcement:
Jacket:
Color Code:

Flexible strand tin copper, ASTM B-172 and ICEA S-75-381/NEMA WC58
Tape separator between conductor and insulation
Ethylene-propylene rubber (EPR), ICEA S-75-381 sec 3.15, table 3-10
Conductors and rubber fillers cabled to form round core
Single faced rubber filled binder tape over insulation
Black heavy duty CPE thermoset compound, ICEA S-75-381 sec 3.4, table 3-4
ICEA S-75-381 sec 3.18; black, white, green, red

FEATURES

APPLICATIONS

- Portable power systems


- Other industrial applications
- Mining application where bare grounding conductors
are not required

Excellent flexibility
Water resistant and flame resistant
Rated and flexible at 40C to +90C
Excellent impact and abrasion resistant
Ozone sunlight oil, grease, weather, chemical resistant

APPROVALS:
UL:
C(UL):
MSHA:

E207132 Oil Resistant; Oil Resistant Inners; Sunlight Resistant; 90C Wet or Dry
E207132 - FT1; FT5; -40C +90C
P-7K-268101

4 CONDUCTOR
Part
Number

W8-4
W6-4
W4-4
W2-4
W1-4
W1/0-4
W2/0-4
W3/0-4
W4/0-4
W250-4
W350-4
W500-4

Power
Conductor
Size

Power
Conductor
Stranding

AWG or MCM

No. of Stranding

8 AWG
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 MCM
350 MCM
500 MCM

133 7x19
259 7x37
259 7x37
259 7x37
259 7x37
266 19x14
342 19x18
418 19x22
532 19x28
627 19x33
888 37x24
1221 37x33

Nominal
Insulation
Thickness

Nominal
O.D.

Ampacity (1)
30C
Ambient Temp.

Approx.
Weight

inches

mm

inches

mm

Ibs/1000 ft

kgs/km

0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.095
0.095
0.095

1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.41
2.41
2.41

0.97
1.11
1.26
1.47
1.71
1.78
1.89
2.02
2.22
2.61
2.92
3.34

24.6
28.3
32.1
36.3
43.4
45.2
48.0
51.4
56.3
66.2
74.2
84.8

656
908
1262
1759
2322
2721
3293
3849
4765
5579
7329
9896

976
1352
1878
2618
3456
4050
4901
5729
7092
8303
10908
14729

52
69
91
121
141
164
189
219
252
281
346
428

(1) Ampacity - Free air measured. Based on continuous duty at 90C conductor temperature per 2011 NEC Table 400.5(A)(2)

STANDARD PRINT LEGEND:


TF CABLE (SIZE) TYPE W PORTABLE POWER CABLE 2000V 90C SUN RES OIL RES 90C WET OR DRY (UL) E207132 C(UL) FT1 FT5 (-40C)
P-7K-268101-MSHA

SPECIAL FACTORY OPTIONS:


Jacket:
MSHA:
CSA:

Other colors available


P-7K-268077 (Neoprene)
1523058 (LR 103932) FT1; FT5; 90C; (-40C) (Neoprene)

www.tfcable.com

phone: 630-406-9000

Issue 7.0, July 2015

2000V W

Portable Power Cable 90C UL C(UL) MSHA


Industrial Grade

SPECIFICATIONS & STANDARDS

ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B172, ASTM B 33, UL 44

CONSTRUCTION:

Conductors:

Separator:
Insulation:
Assembly:
Reinforcement:
Jacket:
Color Code:

Flexible strand tin copper, ASTM B-172 and ICEA S-75-381/NEMA WC58
Tape separator between conductor and insulation
Ethylene-propylene rubber (EPR), ICEA S-75-381 sec 3.15, table 3-16
Conductors and rubber fillers cabled to form round core
Single faced rubber filled binder tape over insulation
Black heavy duty CPE thermoset compound, ICEA S-75-381 sec 3.4, table 3-4
ICEA S-75-381 sec 3.18; black, white, red, green, orange

FEATURES

APPLICATIONS

- Portable power systems


- Other industrial applications
- Mining application where bare grounding conductors
are not required

Excellent flexibility
Water resistant and flame resistant
Rated and flexible at 40C to +90C
Excellent impact and abrasion resistant
Ozone sunlight oil, grease, weather, chemical resistant

APPROVALS:
UL:
C(UL):
MSHA:

E207132 Oil Resistant; Oil Resistant Inners; Sunlight Resistant; 90C Wet or Dry
E207132 - FT1; FT5; -40C +90C
P-7K-268101

5 CONDUCTOR
Part
Number

W8-5
W6-5
W4-5
W2-5
W1-5
W1/0-5
W2/0-5
W3/0-5
W4/0-5

Power
Conductor
Size

Power
Conductor
Stranding

AWG or MCM

No. of Stranding

8 AWG
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG

133 7x19
259 7x37
259 7x37
259 7x37
259 7x37
266 19x14
342 19x18
418 19x22
532 19x28

Nominal
Insulation
Thickness

Nominal
O.D.

Ampacity (1)
30C
Ambient Temp.

Approx.
Weight

inches

mm

inches

mm

Ibs/1000 ft

kgs/km

0.06
0.06
0.06
0.06
0.06
0.08
0.08
0.08
0.08

1.52
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03

1.07
1.24
1.36
1.56
1.85
1.98
2.13
2.27
2.46

27.2
31.5
35.2
39.8
47.1
50.4
54.1
57.6
62.6

776
1024
1432
2051
2665
3406
3596
4728
5512

1154
1524
2131
3052
3967
5069
5351
7035
8203

52
69
91
121
141
164
189
219
252

6 CONDUCTOR
Part
Number

W6-6

Power
Conductor
Size

Power
Conductor
Stranding

AWG or MCM

No. of Stranding

6 AWG

259 7x37

Nominal
Insulation
Thickness

Nominal
O.D.

Ampacity (1)
30C
Ambient Temp.

Approx.
Weight

inches

mm

inches

mm

Ibs/1000 ft

kgs/km

0.06

1.52

1.30

33.0

1272

1891

69

(1) Ampacity - Free air measured. Based on continuous duty at 90C conductor temperature per 2011 NEC Table 400.5(A)(2)

STANDARD PRINT LEGEND:

TF CABLE (SIZE) TYPE W PORTABLE POWER CABLE 2000V 90C SUN RES OIL RES 90C WET OR DRY (UL) E207132 C(UL) FT1 FT5
(-40C) P-7K-268101-MSHA

SPECIAL FACTORY OPTIONS:


Jacket:
MSHA:
CSA:

Other colors available


P-7K-268077 (Neoprene)
1523058 (LR 103932) FT1; FT5; 90C; (-40C) (Neoprene)
Issue 7.0, July 2015

phone: 630-406-9000

www.tfcable.com

G-GC 2000V
Portable Power Cable 90C UL C(UL) MSHA
Industrial Grade

SPECIFICATIONS & STANDARDS


ASTM B 33, UL 44, UL 1581

CONSTRUCTION:

Conductors:
Flexible strand tin copper, Class I UL44 and ASTM B 33
Insulation:
Ethylene-propylene rubber (EPR)
Grounding conductors: Tin copper, insulation color: green
Ground check:
Yellow polypropylene-insulated tin copper conductor
Assembly:
Three power, ground check and two EPR insulated grounding conductors cabled together to form round core
Separator:
Single faced rubber filled binder tape applied overall
Jacket:
Black heavy duty, integral-filled CPE thermoset compound, UL 1581
Color Code:
table 3-4; Black, white, red

FEATURES

APPLICATION

- U
 se on AC off track equipment such as miners, shuttle cars,
cutting machines, loading machines, drills, conveyors, and pumps
- Power to open pit strip and deep mines
- For applications requiring ground check conductor for added safety.

Excellent flexibility
Ozone, sun, weather and flame resistant
Rated and flexible at 40C to 90C
Excellent impact and abrasion resistant
Oil and heat resistant

APPROVALS:
UL:
C(UL):
MSHA:

E207132 Oil Resistant; Oil Resistant Inners; Sunlight Resistant; 90C Wet or Dry
E207132 FT1; FT5; -40C +90C
P-7K-268101

3 CONDUCTOR
Part
Number

GGC8-3
GGC6-3
GGC4-3
GGC2-3
GGC1-3
GGC1/0-3
GGC2/0-3
GGC3/0-3
GGC4/0-3
GGC250-3
GGC350-3
GGC500-3

Size

Power
Conductor
Size

Power
Conductor
Stranding

Ground

Ground
Check

AWG or MCM

No. of Stranding

AWG

8 AWG
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 MCM
350 MCM
500 MCM

133 7x19
133 7x19
259 7x37
259 7x37
259 7x37
266 19x14
342 19x18
418 19x22
532 19x28
627 19x33
888 37x24
1221 37x33

10
10
8
7
6
5
4
2
2
2
1/0
2/0

Ampacity (1)
30C Ambient
Temp.

Nominal
Insulation
Thickness

Nominal
Jacket
Thickness

AWG

inches

inches

inches

mm

Ibs/1000 ft

kgs/km

10
10
10
10
8
8
8
8
8
8
8
8

0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.095
0.095
0.095

0.141
0.141
0.125
0.141
0.141
0.156
0.156
0.156
0.172
0.240
0.240
0.270

0.99
1.05
1.12
1.29
1.41
1.54
1.60
1.74
1.88
2.26
2.48
2.87

25.1
26.6
28.4
32.8
35.8
39.0
40.6
44.3
47.7
57.3
63.1
72.8

661
781
1013
1413
1716
2096
2466
2982
3627
4568
6003
8131

983
1162
1507
2103
2554
3119
3670
4437
5397
6798
8933
12099

65
87
114
152
177
205
237
274
316
352
433
536

Nominal
O.D.

Approx.
Weight

(1) Ampacity - Free air measured. Based on continuous duty at 90C conductor temperature per 2011 NEC Table 400.5(A)(2)

STANDARD PRINT LEGEND:

TF CABLE (SIZE) TYPE G-GC PORTABLE POWER CABLE 2000V 90C SUN RES OIL RES 90C WET OR DRY (UL) E207132 C(UL) FT1 FT5 (-40C)
P-7K-268101-MSHA

SPECIAL FACTORY OPTIONS:

Jacket:
MSHA:
CSA:
Jacket: TPU
MSHA:
6

Other colors available


P-7K-268077 (Neoprene)
1523058 (LR 103932) FT1; FT5; 90C; (-40C) (Neoprene)
Other colors available
P-07-KA030001 (TPU)

www.tfcable.com

phone: 630-406-9000

Issue 7.0, July 2015

2000V G
Portable Power Cable 90C UL C(UL) MSHA
Industrial Grade

SPECIFICATIONS & STANDARDS

ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B172, ASTM B 33, UL 44, UL 1581

CONSTRUCTION:

Conductors:
Insulation:
Grounding cond:
Assembly:
Separator:
Jacket:
Color Code:

Flexible strand tin copper, ASTM B-172 Class I and ICEA S-75-381/NEMA WC58
Ethylene-propylene rubber (EPR); ICEA S-75-381 sec 3.15, table 3-10
ICEA S-75-381; insulation color: green
Four power and four EPR insulated grounding conductors cabled with rubber filler in center to form round core
Single faced rubber filled binder tape applied overall
Black heavy duty CPE thermoset compound, ICEA S-75-381 sec 3.21, table 3-4
ICEA S-75-381 sec 3.21 table 3-4; black, white, red, orange

FEATURES

APPLICATION

- U
 se on AC off track equipment such as miners, shuttle cars,
cutting machines, loading machines, drills, conveyors, and pumps
- Power to open pit strip and deep mines

Excellent flexibility
Ozone, sun, weather and flame resistant
Rated and flexible at 40C to 90C
Excellent impact and abrasion resistant
Oil and heat resistant

APPROVALS:
UL:
C(UL):
MSHA:

E207132 Oil Resistant; Oil Resistant Inners; Sunlight Resistant; 90C Wet or Dry
E207132 - FT1; FT5; -40C +90C
P-7K-268101

4 CONDUCTOR
Power
Conductor
Size

Power
Conductor
Stranding

Grounding
Conductor
Size

Nominal
Insulation
Thickness

AWG or MCM

No. and Diameters


of Stranding

AWG

inches

inches

mm

lbs/1000ft

kgs/km

12
12
10
9
8
7
6
5
4
3
1
1/0

0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.095
0.095
0.095

0.99
1.10
1.27
1.48
1.68
1.79
1.93
2.07
2.26
2.66
2.98
3.40

25.1
27.9
32.3
37.6
42.7
45.5
49.0
52.6
57.4
67.6
75.7
86.4

748
910
1378
1914
2311
2810
3253
4099
4925
6060
8126
10758

1113
1354
2050
2848
3439
4181
4842
6100
7329
9018
12093
16010

52
69
91
121
141
164
189
219
252
281
346
428

Part
Number

G8-4
G6-4
G4-4
G2-4
G1-4
G1/0-4
G2/0-4
G3/0-4
G4/0-4
G250-4
G350-4
G500-4

8 AWG
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 MCM
350 MCM
500 MCM

133 7x19
259 7x37
259 7x37
259 7x37
259 7x37
266 19x14
342 19x18
259 37x7
532 19x28
627 19x33
888 37x24
1221 37x33

Nominal
O.D.

Ampacity (1)
30C Ambient Temp.

Approx.
Weight

(1) Ampacity - Free air measured. Based on continuous duty at 90C conductor temperature per 2011 NEC Table 400.5(A)(2)

STANDARD PRINT LEGEND:

TF CABLE (SIZE) TYPE G PORTABLE POWER CABLE 2000V 90C SUN RES OIL RES 90C WET OR DRY (UL) E207132 C(UL) FT1 FT5 (-40C)
P-7K-268101-MSHA

SPECIAL FACTORY OPTIONS:


Jacket:
MSHA:
CSA:
Jacket: TPU
MSHA:

Other colors available


P-7K-268077 (Neoprene)
1523058 (LR 103932) FT1; FT5; 90C; (-40C) (Neoprene)
Other colors available
P-07-KA030001 (TPU)

Issue 7.0, July 2015

phone: 630-406-9000

www.tfcable.com

DLO/RHH/RHW-2/RW90/RW90-TC 2000V
Portable Power Cable 90C UL CSA MSHA
Industrial Grade

SPECIFICATIONS & STANDARDS

UL 44, ICEA S-95-658/NEMA WC70, UL 1685, IEEE-1202, CSA C22.2 No. 38, CSA C22.2 No. 230, ASTM B 8, ASTM B 33, AAR, RP-588 RP-586

CONSTRUCTION:

Nominal voltage:
Conductors:
Separator:
Insulation:
Jacket:
Bending radius:

RHH/RHW-2 600V and 2000V, RW-90 CSA, 1kV, DLO 2kV


Flexible strand tin coated copper conductor, B-172, ASTM B-33
Tape separator between conductor and insulation
Ethylene-propylene rubber (EPR), UL, CSA, ICEA, AAR RP-588, 90C
Black heavy duty, thermoset CPE, ICEA S-95-658 NEMA WC70, AAR RP-586
For fixed minimum 4xD, for flexible minimum 6xD, D diameter of cable

FEATURES

APPLICATION

UL listed RHH/RHW-2 600 V and 2000V for black jacket


Rated 2kV DLO, 1kV RW90
90C (dry) 90C (wet)
Ozone, sunlight, oil, grease, weather, water, chemical and abrasion resistant jacket
Rated RW90-TC (Tray Cable) for sizes 1/0 AWG and larger
MSHA,VW-1, SUN RES, FOR CT USE for sizes 1/0 AWG and larger and for black jacket
Limited Smoke (LS) ST1 in accordance with (UL) 1685
CSA listed RW90, RW90-TC (for black jacket) 1kV

Designed for uses requiring a flexible heavy duty power cables


For portable or fixed installations
Leads for motors, generators, batteries, jumper cables
Deep well Submersible Pump Cable
For use in renewable energy applications.
Shipyard and railroad applications.

APPROVALS:

UL: E193954 (CPE jacket) RHW-2 90C wet and dry, VW-1, Sun Res, for 1/0 and larger ST-1, FT-4, IEEE1202, for CT use
C(UL):
E193954: TYPE RW90 EPR; 1000V; FT1
CSA:
1101269 LL103932: 205591; RW-90 90C; FT1; FT4; -40C; for 1/0AWG and larger: OIL RES, Tray Cable, Sun Res
MSHA:
P-7268080-01-MSHA

Part
Number

DLO14
DLO12
DLO10
DLO8
DLO6
DLO4
DLO2
DLO1
DLO1/0
DLO2/0
DLO3/0
DLO4/0

Power
Conductor
Size

Power
Conductor
Stranding

Conductor
Diameter

Nominal
Insulation
Thickness

Nominal
Jacket
Thickness

AWG or MCM

No. of Stranding

inches

inches

inches

inches

mm

0.074
0.094
0.128
0.147
0.207
0.264
0.314
0.390
0.420
0.460
0.555
0.587

0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080

0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.045
0.045
0.045
0.045
0.045

0.193
0.217
0.248
0.323
0.362
0.413
0.489
0.583
0.642
0.681
0.781
0.815

4.9
5.5
6.3
8.2
9.2
10.5
12.4
14.8
16.3
17.3
19.8
20.7

14 AWG
12 AWG
10 AWG
8 AWG
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG

19/27
19/25
27/24
37/24
61/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24

Nominal
O.D.

Ampacity
at Ambient
Temp. 30C

Approx.
Weight
Ibs/1000 ft
25
46
67
95
134
192
248
428
480
558
742
872

kgs/km
37
68
100
141
199
286
369
637
714
830
1104
1298

A
35
40
55
80
105
140
190
220
260
300
350
405

*** Based on single conductor in free air, 30C ambient air temperature 90C conductor temperature per 2005 NEC Table 310.17

STANDARD PRINT LEGEND:


1 AWG AND SMALLER: TF CABLE (SIZE) 90C DLO 2KV P-7K-268080-01-MSHA - E193954 (UL) RHW2 2KV VW1 SUN RES - (CSA) 205591
RW90 EPR 1000V -40C FT1 FT4


1/0 AWG AND LARGER: TF CABLE (SIZE) 90C DLO 2KV P-7K-268080-01-MSHA - E193954 (UL) RHW2 2KV VW-1 ST1 SUN RES (CSA)
205591 RW90 EPR 1000V -40C FT1 FT4 TC SR OIL RES

SPECIAL FACTORY OPTION:

INTERTEK HIGH TORSION TESTED ABD INSPECTED RHH/RHW-2/RW90/DLO WIND 2000V


8

www.tfcable.com

phone: 630-406-9000

Issue 7.0, July 2015

2000V DLO/RHH/RHW-2/RW90/RW90-TC
Portable Power Cable 90C UL CSA MSHA
Industrial Grade

SPECIFICATIONS & STANDARDS

UL 44, ICEA S-95-658/NEMA WC70, UL 1685, IEEE-1202, CSA C22.2 No. 38, CSA C22.2 No. 230, ASTM B 8, ASTM B 33, AAR, RP-588 RP-586

CONSTRUCTION:

Nominal voltage:
Conductors:
Separator:
Insulation:
Jacket:
Bending radius:

RHH/RHW-2 600V and 2000V, RW-90 CSA, 1kV, DLO 2kV


Flexible strand tin coated copper conductor, B-172, ASTM B-33
Tape separator between conductor and insulation
Ethylene-propylene rubber (EPR), UL, CSA, ICEA, AAR RP-588, 90C
Black heavy duty, thermoset CPE, ICEA S-95-658 NEMA WC70, AAR RP-586
For fixed minimum 4xD, for flexible minimum 6xD, D diameter of cable

FEATURES

APPLICATION

UL listed RHH/RHW-2 600 V and 2000V for black jacket


Rated 2kV DLO, 1kV RW90
90C (dry) 90C (wet)
Ozone, sunlight, oil, grease, weather, water, chemical and abrasion resistant jacket
Rated RW90-TC (Tray Cable) for sizes 1/0 AWG and larger
M
 SHA,VW-1, SUN RES, FOR CT USE for sizes 1/0 AWG and larger and for black jacket
Limited Smoke (LS) ST1 in accordance with (UL) 1685
CSA listed RW90, RW90-TC (for black jacket) 1kV

Designed for uses requiring a flexible heavy duty power cables


For portable or fixed installations
Leads for motors, generators, batteries, jumper cables
Deep well Submersible Pump Cable
For use in renewable energy applications.
Shipyard and railroad applications.

APPROVALS:

UL: E193954 RHW-2 90C wet and dry, VW-1, Sun Res, for 1/0 and larger ST-1, FT-4, IEEE1202, for CT use
C(UL):
E193954: TYPE RW90 EPR; 1000V; FT1
CSA:
1101269 LL103932: 205591; RW-90 90C; FT1; FT4; -40C; for 1/0AWG and larger: OIL RES, Tray Cable, Sun Res
MSHA:
P-7268080-01-MSHA

Part
Number

DLO262
DLO313
DLO373
DLO444
DLO535
DLO646
DLO777
DLO929
DLO1111

Power
Conductor
Size

Power
Conductor
Stranding

Conductor
Diameter

Nominal
Insulation
Thickness

Nominal
Jacket
Thickness

AWG or MCM

No. of Stranding

inches

inches

inches

inches

mm

Ibs/1000 ft

kgs/km

262 MCM
313 MCM
373 MCM
444 MCM
535 MCM
646 MCM
777 MCM
929 MCM
1111 MCM

650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2300/24
2750/24

0.660
0.725
0.787
0.870
0.950
1.040
1.130
1.208
1.370

0.095
0.095
0.095
0.095
0.110
0.110
0.110
0.110
0.125

0.065
0.065
0.065
0.065
0.065
0.065
0.065
0.065
0.095

0.921
0.984
1.055
1.138
1.244
1.355
1.433
1.516
1.791

23.4
25.1
26.8
28.9
31.6
33.9
36.4
38.5
45.5

1068
1258
1462
1726
2018
2416
2881
3455
4077

1589
1872
2176
2568
3046
3595
4287
5142
6067

471
511
590
656
731
815
905
1005
1115

Nominal
O.D.

Ampacity
at Ambient
Temp. 30C

Approx.
Weight

*** Based on single conductor in free air, 30C ambient air temperature 90C conductor temperature per 2005 NEC Table 310.17

STANDARD PRINT LEGEND:


TF CABLE (SIZE) 90C DLO 2KV P-7K-268080-01-MSHA - E193954 (UL) RHW2 2KV VW-1 ST1 SUN RES (CSA) 205591 RW90 EPR 1000V -40C
FT1 FT4 TC SR OIL RES

SPECIAL FACTORY OPTION:

INTERTEK HIGH TORSION TESTED AND INSPECTED RHH/RHW-2/RW90/DLO WIND 2000V

Issue 7.0, July 2015

phone: 630-406-9000

www.tfcable.com

W 2000V

Multi Conductor Portable Power Cable 90C UL C(UL) MSHA


Mining Grade

SPECIFICATIONS & STANDARDS

CSA C22.2 No. 96-03, ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B172, ASTM B 33, UL 44

CONSTRUCTION:

Conductors:

Separator:
Insulation:
Assembly:
Reinforcement:
Jacket:
Color Code:

Flexible strand tin copper, ASTM B-172


Tape separator between conductor and insulation
Ethylene-propylene rubber (EPR), C22.2 No. 96-03, sec 5.1.4
Conductors and rubber fillers cabled to form round core
Nylon open braid applied overall
Black heavy duty CPE thermoset compound, C22.2 No. 96-03, sec 5.1.11.2 sec. 4.3.9.2 table 1
black, blue, red, green C22.2 No. 96-03 table 1

FEATURES

APPLICATIONS

Excellent flexibility
Water resistant and flame resistant
Rated and flexible at 40C to +90C
Excellent impact and abrasion resistant
Ozone sunlight oil, grease, weather, chemical resistant

APPROVALS:
UL:
C(UL):
MSHA:

Portable power systems


Other industrial applications
Magnetic cranes
Mining application where bare grounding conductors
are not required

E207132 Oil Resistant; Oil Resistant Inners; Sunlight Resistant; 90C Wet or Dry
E207132 - FT1; FT5; -40C +90C
P-7K-268101

4 CONDUCTOR
Part
Number

W2/0-4MNG-CAN
W4/0-4MNG-CAN

Power
Conductor
Size

Power
Conductor
Stranding

AWG or MCM

No. of Stranding

2/0 AWG
4/0 AWG

342 19x18
532 19x28

Nominal
Insulation
Thickness
inches
0.080

Nominal
O.D.

Ampacity (1)
30C
Ambient Temp.

Approx.
Weight

mm

inches

mm

Ibs/1000 ft

kgs/km

2.03

1.89
2.22

48.0
56.3

3293
4765

4901
7092

189
252

(1) Ampacity - Free air measured. Based on continuous duty at 90C conductor temperature per 2011 NEC Table 400.5(A)(2)

STANDARD PRINT LEGEND:

TF CABLE (SIZE) TYPE W PORTABLE POWER CABLE 2000V 90C SUN RES OIL RES 90C WET OR DRY (UL) E207132 C(UL) FT1 FT5
(-40C) P-7K-268101-MSHA

SPECIAL FACTORY OPTIONS:


Jacket:
MSHA:
CSA:

10

Other colors available


P-7K-268077 (Neoprene)
1523058 (LR 103932) FT1; FT5; 90C; (-40C) (Neoprene)

www.tfcable.com

phone: 630-406-9000

Issue 7.0, July 2015

2000V G-GC
Portable Power Cable 90C UL C(UL) MSHA
Mining Grade

SPECIFICATIONS & STANDARDS

ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B 172, ASTM B 33

CONSTRUCTION:

Conductors:

Separator:
Insulation:
Grounding cond:
Ground check:
Assembly:


Jacket:
Color Code:

Flexible strand tin copper, ASTM B 172 and ICEA S-75-381


Tape separator between the conductor and insulation
Ethylene-propylene rubber (EPR), ICEA S-75-381 sec 3.15, table 3-12
Tin copper, ICEA S-75-381, table 3-12
Yellow Polypropylene-Insulation tin copper conductor, ICEA S-75-381 table 3-21
Sizes 4/0 and smaller: Three power, ground check and two polyester (green mylar) taped grounding conductors cabled together;
Nylon open braid applied overall. Sizes 250 MCM and larger: Three power, ground check and two polyester (green mylar) taped
grounding conductors cabled together to form round core; Single faced rubber filled binder tape applied overall
Black extra heavy duty, integral-filled CPE thermoset compound, ICEA S-75-381 sec 3.21, table 3-3
ICEA S-75-381 sec 3.18; black, white, red

FEATURES

APPLICATION

- For use as trailing mining cable.


- Use on AC off track equipment such as miners, shuttle cars, cutting machines loading
machines and drills as well as conveyors and pumps
- Supply power to open pit strip and deep mines
- For applications requiring ground check conductor for added safety.

Excellent flexibility
Highly ozone, sun, weather and flame resistant
Rated and flexible at 40C
Excellent impact and abrasion resistant
Special construction for reeling and trailing
Oil and heat resistant
Indent printed for easy identification

APPROVALS:
UL:
C(UL):
MSHA:

E207132 Oil Resistant; Oil Resistant Inners; Sunlight Resistant; 90C Wet or Dry
E207132 - FT1; FT5; -40C +90C
P-7K-268101

3 CONDUCTOR
Part
Number

GGC2-3MNG
GGC1-3MNG
GGC1/0-3MNG
GGC2/0-3MNG
GGC4/0-3MNG
GGC350-3MNG

Power
Conductor
Size

Power
Conductor
Stranding

AWG or MCM

No. of Stranding

2 AWG
1 AWG
1/0 AWG
2/0 AWG
4/0 AWG
350 MCM

259
259
266
342
532
888

7x37
7x37
19x14
19x18
19x28
37x24

Size
Ground

Ground
Check

Nominal
Insulation
Thickness

Nominal
Jacket
Thickness

AWG

AWG

inches

inches

inches

mm

Ibs/1000 ft

7
6
5
4
2
1/0

10
8
8
8
8
6

0.060
0.080
0.080
0.080
0.080
0.095

0.165
0.170
0.170
0.190
0.205
0.280

1.34
1.51
1.65
1.75
2.04
2.68

34.0
38.4
41.9
44.5
51.8
68.1

1461
1861
2256
2695
3889
6482

Nominal
O.D.

Ampacity (1)
30C Ambient
Temp.

Approx.
Weight
kgs/km
2176
2772
3360
4014
5791
9652

A
152
177
205
237
316
433

(1) Ampacity - Free air measured. Based on continuous duty at 90C conductor temperature per 2011 NEC Table 400.5(A)(2)

STANDARD PRINT LEGEND:

TF CABLE (SIZE) TYPE G-GC PORTABLE POWER CABLE 2000V 90C SUN RES OIL RES 90C WET OR DRY (UL) E207132 C(UL) FT1 FT5 (-40C)
P-7K-268101-MSHA

SPECIAL FACTORY OPTIONS:

Jacket:
MSHA:
CSA:
Jacket: TPU
MSHA:

Other colors available


P-7K-268077 (Neoprene)
1523058 (LR 103932) - FT1; FT5; 90C; (-40C) (Neoprene)
Other colors available
P-07-KA030001 (TPU)
Issue 7.0, July 2015

phone: 630-406-9000

www.tfcable.com

11

G-GC 2000V

Portable Power Cable 90C UL C(UL) MSHA


Mining Grade

SPECIFICATIONS & STANDARDS

CSA C22.2 No. 96-03, ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B 172, ASTM B 33

CONSTRUCTION:

Conductors:
Separator:

Insulation:
Grounding cond:
Ground check:
Assembly:


Reinforcement:
Jacket:
Color Code:

Flexible strand tin copper, ASTM B 172 and C22.2 No. 96-03 table 9
Tape separator between conductor and insulation C22.2 No. 96-03 sec 4.3.4 table 4
Ethylene-propylene rubber (EPR), C22.2 No. 96-03 table 11
Tin copper, C22.2 No. 96-03 sec 5.1.4.3 and 5.1.4.4
Yellow polypropylene-insulated tin copper conductor, C22.2 No. 96-03 sec 5.1.4
Sizes 4/0 and smaller: Three power, ground check and two polyester (green mylar) taped grounding conductors cabled together;
Sizes 250 MCM and larger: Three power, ground check and two polyester (green mylar) taped grounding conductors cabled
together to form round core; Single faced rubber filled binder tape applied overall
Nylon open braid applied overall
Black extra heavy duty, integral-filled CPE thermoset compound, C22.2 No. 96-03 sec 5.1.11.2 and 4.3.9.2 table 5
black, blue, red; C22.2 No. 96-03 table 1

FEATURES

APPLICATION

- For use as trailing mining cable.


- Use on AC off track equipment such as miners, shuttle cars, cutting machines loading
machines and drills as well as conveyors and pumps
- Supply power to open pit strip and deep mines
- For applications requiring ground check conductor for added safety.

Excellent flexibility
Highly ozone, sun, weather and flame resistant
Rated and flexible at 40C
Excellent impact and abrasion resistant
Special construction for reeling and trailing
Oil and heat resistant
Indent printed for easy identification

APPROVALS:
UL:
C(UL):
MSHA:

E207132 Oil Resistant; 90C Wet or Dry; Sunlight resistant; Oil Resistant inners
E207132 - FT1; FT5; -40C +90C
P-7K-268101

3 CONDUCTOR
Part
Number

GGC8-3MNG-CAN
GGC6-3MNG-CAN
GGC4-3MNG-CAN
GGC2-3MNG-CAN
GGC1-3MNG-CAN
GGC1/0-3MNG-CAN
GGC2/0-3MNG-CAN
GGC3/0-3MNG-CAN
GGC4/0-3MNG-CAN

Power
Conductor
Size

Power
Conductor
Stranding

AWG or MCM

No. of Stranding

8 AWG
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG

133
133
259
259
259
266
342
418
532

7x19
7x19
7x37
7x37
7x37
19x14
19x18
19x22
19x28

Size

Ampacity (1)
30C Ambient
Temp.

Ground

Ground
Check

Nominal
Insulation
Thickness

Nominal
Jacket
Thickness

AWG

AWG

inches

inches

inches

mm

Ibs/1000 ft

kgs/km

10
10
8
7
6
5
4
2
2

10
10
10
8
8
8
8
8
8

0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080

0.134
0.146
0.146
0.165
0.170
0.170
0.190
0.197
0.205

0.97
1.05
1.19
1.34
1.51
1.65
1.75
1.89
2.04

24.6
26.7
30.2
34.0
38.4
41.9
44.5
48.0
51.8

636
785
1086
1461
1861
2256
2695
3203
3889

947
1168
1617
2176
2772
3360
4014
4770
5791

65
87
114
152
177
205
237
274
316

Nominal
O.D.

Approx.
Weight

(1) Ampacity - Free air measured. Based on continuous duty at 90C conductor temperature per 2011 NEC Table 400.5(A)(2)

STANDARD PRINT LEGEND:

TF CABLE (SIZE) TYPE G-GC PORTABLE POWER CABLE 2000V 90C SUN RES OIL RES 90C WET OR DRY (UL) E207132 C(UL) FT1 FT5
(-40C) P-7K-268101-MSHA

SPECIAL FACTORY OPTIONS:


Jacket:
MSHA:
CSA:
Jacket: TPU
MSHA:

12

Other colors available


P-7K-268077 (Neoprene)
1523058 (LR 103932) - FT1; FT5; 90C; (-40C) (Neoprene)
Other colors available
P-07-KA030001 (TPU)

www.tfcable.com

phone: 630-406-9000

Issue 7.0, July 2015

5000V / 15000V

MP-GC

Mine Power Feeder Cable XLP / PVC 90C MSHA


Mining Grade

SPECIFICATIONS & STANDARDS

UL 1072, ASTM B 8, ICEA S-75-381/NEMA WC58

CONSTRUCTION:

Conductor:

Conductor shield:
Insulation:
Insulation shield:
Grounding cond:
Ground check :
Assembly:

Reinforcement:
Jacket:
Color Code:

Bare copper, concentric strand ASTM B 8


Extruded semi-conducting compound
Cross-linked polyethylene (XLP) 90C
Extruded semi-conducting compound, copper tape 0.003
Bare copper Class B
Bare copper, ICEA S-75-381 sec 4.6; Yellow XLP 45mils insulation
Three power conductor, ground check and two non-insulated grounding conductors cabled
together with rubber fillers to form round core; Estrofol binder tape applied overall
Reinforcement applied over the assembly for mechanical strength
Black flame retardant PVC, ICEA S-75-381 table 4-7
Color code tape: black, white, red applied under metallic shielding tape provides circuit identification,
ICEA S-75-381 sec 4.6

FEATURES

APPLICATION

- Shielded high voltage power distribution cable suitable for


installation in bore holes, shafts, horizontal runs in underground
entries, aerial suspension on insulators and other semi-permanent
and permanent mining and industrial feeder installations

Maximum continuous conductor temperature 90C


Flame resistant
Oil resistant upon special request
Indent printed for easy identification

APPROVALS:

MSHA:
P-7K-254064-1
CSA certified product available

5000V 100% INSULATION LEVEL


Part Number

Size

Power
Conductor
Size

Power
Conductor
Stranding

Ground
Check

Nominal
Insulation
Thickness

Nominal
Jacket
Thickness

Ground

AWG or MCM

No. of Stranding

AWG

AWG

inches

inches

inches

mm

Ibs/1000 ft

kgs/km

Nominal
O.D.

Ampacity(1)
40C Ambient
Temp.

Approx.
Weight

MPGC5KV2/0-3
MPGC5KV4/0-3

2/0
4/0

19
37

3
1

0.090

0.110
0.140

1.81
2.06

46.0
52.3

2660
3760

3970
5600

243
321

MPGC5KV2/0-3-RED

2/0

19

0.090

0.110

1.81

46.0

2660

3970

243

Nominal
Insulation
Thickness

Nominal
Jacket
Thickness

inches

inches

inches

mm

0.175

0.140

2.20
2.45

55.9
62.2

(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature

STANDARD PRINT LEGEND:

TF CABLE 5000V (SIZE) GROUNDED MP-GC P-7K-254064-MSHA

15000V 100% INSULATION LEVEL


Part Number

MPGC15KV2/0-3
MPGC15KV4/0-3

Power
Conductor
Size

Power
Conductor
Stranding

Ground

AWG or MCM

No. of Stranding

AWG

2/0 AWG
4/0 AWG

19
37

Size

3
1

Ground
Check
AWG
8

Nominal
O.D.

Ampacity(1)
40C Ambient
Temp.

Approx.
Weight
Ibs./1000 ft.
3190
4310

kgs/km

4760
6430

246
325

(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature

STANDARD PRINT LEGEND:

TF CABLE 15000V (SIZE) GROUNDED MP-GC P-7K-254064-1-MSHA

SPECIAL FACTORY OPTIONS:


Jacket:

Other colors available


Issue 7.0, July 2015

phone: 630-406-9000

www.tfcable.com

13

MP-GC 8000V / 15000V


Mine Power Feeder Cable Extra Heavy Duty EPR / CPE 90C MSHA
Mining Grade

SPECIFICATIONS & STANDARDS

ICEA S-75-381/NEMA WC58, ASTM B 8

CONSTRUCTION:

Conductor:
Conductor shield:
Insulation:
Insulation shield:
Grounding cond:
Ground check:
Assembly:

Jacket:
Color code:

Bare copper, concentric strand ASTM B 8


Semi-conducting tape and compound, ICEA S-75-381 sec 3.14
Ethylene-propylene rubber (EPR), ICEA S-75-381, table 4-3/4-4
Semi-conducting compound, ICEA S-75-381 and 0.005 copper tape
Tin copper Class B, ICEA S-75-381, table 4-1
Bare copper, ICEA S-75-381 table 4-1; insulation color: yellow
Three power conductor, ground check and two non-insulated grounding conductors cabled with rubber fillers
to make a round core; Single faced rubber filled binder tape applied overall
Black extra heavy duty CPE thermoset compound, ICEA S-75-381, table 3-3, 3-22, sec. 3.21
Color code tape: black, white, red applied under metallic shielding tape provides circuit identification,
ICEA S-75-381 sec 4.6

FEATURES

APPLICATION

- For use up to 8000 volts when installed in ducts, conduits, open air and for direct
burial in wet and dry locations
- For semi-permanent and permanent installations in tunnels, shafts and bore holes.
- Other industrial and mining applications requiring shielding.

Ozone, sun, weather and flame resistant


Oil and heat resistant
Maximum continuous conductor temperature 90C
Indent printed for easy identification

APPROVALS:
MSHA:

P-07-KA050003-1

8000V 100% INSULATION LEVEL


Part
Number

MPGC8KV2/0-3-CPE

Power
Conductor
Size

Power
Conductor
Stranding

AWG or MCM
2/0 AWG

Size
Ground

Ground
Check

Nominal
Insulation
Thickness

Nominal
Jacket
Thickness

No. of Stranding

AWG

AWG

inches

inches

inches

mm

Ibs/1000 ft

kgs/km

19

0.115

0.140

1.88

47.8

2900

4316

Nominal
Insulation
Thickness

Nominal
Jacket
Thickness

inches

inches

inches

mm

Ibs/1000 ft

kgs/km

0.140

1.88
2.40

47.8
61.0

2285
4605

3400
6853

Nominal
O.D.

Approx.
Weight

15000V 100% INSULATION LEVEL


Part
Number

MPGC15KV2-3-CPE
MPGC15KV4/0-3-CPE

Size

Power
Conductor
Size

Power
Conductor
Stranding

Ground

Ground
Check

AWG or MCM

No. of Stranding

AWG

AWG

2 AWG
4/0 AWG

7
37

6
1

0.175

Nominal
O.D.

Approx.
Weight

ELECTRICAL AND MECHANICAL PARAMETERS


Power-Grounding
Conductor Size

Power
Conductor
Resistance
at 25C

Grounding
Conductor
Resistance
at 25C

Ground Check
Conductor
Resistance
at 25C

Inductance
per length
unit

Operating
Capacitance per
length unit

Permissible
short-circuit
Current(2) (1s)

Ampacity(1)
40C
Ambient
Temp.

Maximum
Permissible
Tension
Force

AWG or MCM

/1000Ft

/1000Ft

/1000Ft

mH/1000Ft

F/1000Ft

kA

2/0 AWG 3 AWG


4/0 AWG 1 AWG

0.081
0.051

0.213
0.134

0.652

0.098
0.093

0.14
0.16

9.64
15.30

243
321

4000
6400

(1) Ampacity- Free air measured; Based on continuous duty at 90C conductor temperature

STANDARD PRINT LEGEND:

(2) Short-circuit current (1s) Based on conductor temperature from 90C up to 250C

TF CABLE 8000V (SIZE) GROUNDED MP-GC P-07-KA050003-1-MSHA;


TF CABLE 15000V (SIZE) GROUNDED MP-GC P-07-KA050003-1-MSHA
14

www.tfcable.com

phone: 630-406-9000

SPECIAL FACTORY OPTIONS:


Jacket: Other colors available
Neoprene
Issue 7.0, July 2015

2000V SHD-GC
Portable Power Cable Extra Heavy Duty EPR / NEO 90C MSHA
Mining Grade
SPECIFICATIONS & STANDARDS

ICEA S-75-381/NEMA WC58, ASTM B 172, ASTM B 33

CONSTRUCTION:

Conductors:
Flexible strand tinned copper conductor, ASTM B-172 and ICEA S-75-381, table 3-22
Separator:
Polyester tape between conductor and insulation. ICEA S-75-381
Insulation:
Ethylene-propylene rubber (EPR) ICEA S-75-381, table 3-22
Insulation Shield: Non-conducting bedding tape and composite tinned copper/polyamide braid 60% minimum coverage
Color Code:
Polyamide braid color code - black, white, red, ICEA S-75-381
Grounding Cond: Tinned copper - ICEA S-75-381 Tab. 3-25
Ground Check:
Yellow polypropylene-insulated tinned copper conductor, ICEA S-75-381 Tab. 3-22
Cable Assembly:
Three power conductors, ground check and two non-insulated grounding conductors cabled together to form a round cable core
Separator:
Nylon open braid applied overall
Jacket: 
Black, extra heavy duty, high torsion-resistant, integral-filled, reinforced Neoprene thermoset jacket, ICEA S-75-381
Tab. 3-3, 3-22, Sec. 3.21
FEATURES

APPLICATION

- For use as trailing mining cables.


- Use on AC off track equipment such as longwall & continuous miners, loaders, blast hole drillers,
conveyors, pumps and mobile equipment requiring grounding conductors and ground check
and metallic shielding overall.
- For use in applications where ground check conductor is required for added safety.
- Maximum continuous conductor temperature 90C

Excellent flexibility
Highly ozone, sun, weather, water and flame resistant
Rated and flexible at 40C
Excellent impact and abrasion resistant
Oil and heat resistant
Indent printed for easy identification

APPROVALS:

MSHA:

P-07-KA060012
Power
Conductor
Size

Part
Number

Power
Conductor
Stranding

Size

AWG

AWG

10
10
10
8
8
8
8
8
8

12
12
10
10
8
6
4
3
1

AWG or MCM No. of Stranding


SHDGC2KV12-3
SHDGC2KV10-3
SHDGC2KV8-3
SHDGC2KV6-3
SHDGC2KV4-3
SHDGC2KV2-3
SHDGC2KV1/0-3
SHDGC2KV2/0-3
SHDGC2KV4/0-3

12 AWG
10 AWG
8 AWG
6 AWG
4 AWG
2 AWG
1/0 AWG
2/0 AWG
4/0 AWG

49
49
133
133
259
259
266
342
532

Grounding
Conductor

Ground Check
Conductor
Size

7X7
7X7
7x19
7x19
7x37
7x37
19x14
19x18
19x28

Stranding

Nominal
Insulation
Thickness

Nominal
Jacket
Thickness

No. of Wires

inches

inches

inches

mm

Ibs/1000ft

kgs/km

49
49
49
49
133
133
259
259
259

0.070
0.070
0.070
0.070
0.070
0.070
0.080
0.080
0.080

0.125
0.125
0.155
0.155
0.155
0.170
0.190
0.205
0.220

0.92
0.95
1.13
1.26
1.36
1.55
1.81
1.94
2.24

23.4
24.1
28.7
32.0
34.5
39.4
46.0
49.3
56.9

557
623
818
1076
1308
1874
2694
3301
4701

829
927
1217
1601
1947
2789
4009
4913
6996

7x7
7x7
7x7
7x7
7x19
7x19
7x37
7x37
7x37

Nominal
O.D.

Approx.
Weight

ELECTRICAL AND MECHANICAL PARAMETERS


Conductor Size
Power

Grounding

AWG or MCM
6 AWG
4 AWG
2 AWG
1/0 AWG
2/0 AWG
4/0 AWG

10 AWG
8 AWG
6 AWG
4 AWG
3 AWG
1 AWG

Power
Conductor
Resistance
at 25C

Grounding
Conductor
Resistance
at 25C

Ground Check
Conductor
Resistance
at 25C

/1000Ft

/1000Ft

/1000Ft

mH/1000Ft

F/1000Ft

0.679

0.118
0.107
0.101
0.097
0.092
0.088

0.09
0.11
0.13
0.14
0.16
0.19

0.436
0.274
0.172
0.109
0.0868
0.0546

1.109
0.697
0.436
0.274
0.227
0.137

Ampacity(1)
40C
Ambient
Temp.

Maximum
Permissible
Tensile Force

kA

1.90
3.03
4.80
7.65
9.64
15.30

93
122
159
211
243
321

600
950
1500
2400
3000
4800

Operating
Permissible ShortInductance
Capacitance per
Circuit
per unit length
unit length
Current(2) (1s)

(1) Ampacity- Free air measured; Based on continuous duty at 90C conductor temperature (2) Short-circuit current (1s) Based on conductor temperature from 90C up to 250C

STANDARD PRINT LEGEND:

TF CABLE (VOLTAGE) (SIZE) TYPE SHD-GC


FT1 FT5 (-40C) +90C P-07-KA060012-MSHA

Issue 7.0, July 2015

SPECIAL FACTORY OPTIONS:


Jacket:
MSHA:
Jacket: TPU
MSHA:

Red, yellow, green, orange, blue


P-7K-268101 (CPE)
Red, yellow, green, orange, blue
P-07-KA030001 (TPU)

phone: 630-406-9000

www.tfcable.com

15

SHD-GC 2000V
Portable Power Cable Extra Heavy Duty EPR / NEO 90C CSA MSHA
Mining Grade

SPECIFICATIONS & STANDARDS

ICEA S-75-381/NEMA WC58, ASTM B 172, ASTM B 33, CSA C22.2 No. 96-09

CONSTRUCTION:

Conductors:
Flexible strand tinned copper, ASTM B 172 and ASTM B33, C22.2 No. 96-09 sec 6.1.2 table 9
Separator:
Polyester tape between conductor and insulation
Insulation:
Ethylene-propylene rubber (EPR) C22.2 No. 96-09 sec 5.3.4 table 2 & 4
Insulation Shield: Non-conducting bedding tape and composite tinned copper/polyamide braid 60% minimum coverage
Color Code:
Polyamide braid color code - black, red, blue C22.2 No. 96-09 table 1
Grounding Cond: Tinned copper - C22.2 No. 96-09 sec 5.3.2
Ground Check:
Yellow polypropylene-insulated tinned copper conductor, C22.2 No. 96-09 sec 5.3.3 table 4A
Cable Assembly:
Three power conductors, ground check and two non-insulated grounding conductors cabled together to form a round cable core
Separator:
Nylon open braid applied overall
Jacket: 
Black, extra heavy duty, high torsion-resistant, integral-filled, reinforced Neoprene thermoset jacket, C22.2 No. 96-09 sec 5.3.9 table 2 & 5
FEATURES

APPLICATION

- For use as trailing mining cables.


- Use on AC off track equipment such as longwall & continuous miners, loaders,
blast hole drillers, conveyors, pumps and mobile equipment requiring grounding
conductors and ground check and metallic shielding overall.
- For use in applications where ground check conductor is required for added safety.
- Maximum continuous conductor temperature 90C

Excellent flexibility
Highly ozone, sun, weather, water and flame resistant
Rated and flexible at 40C
Excellent impact and abrasion resistant
Oil and heat resistant
Indent printed for easy identification

APPROVALS:
CSA:
MSHA:

1523058 (LR 103932) - FT1; FT5; -40C +90C


P-07-KA060012
Power
Conductor
Size

Part
Number

Power
Conductor
Stranding

Size

AWG

AWG

10
10
10
8
8
8
8
8
8

12
12
10
10
9
7
5
4
2

AWG or MCM No. of Stranding


SHDGC2KV12-3
SHDGC2KV10-3
SHDGC2KV8-3
SHDGC2KV6-3
SHDGC2KV4-3
SHDGC2KV2-3
SHDGC2KV1/0-3
SHDGC2KV2/0-3
SHDGC2KV4/0-3

12 AWG
10 AWG
8 AWG
6 AWG
4 AWG
2 AWG
1/0 AWG
2/0 AWG
4/0 AWG

49
49
133
133
259
259
266
342
532

Grounding
Conductor

Ground Check
Conductor
Size

7X7
7X7
7x19
7x19
7x37
7x37
19x14
19x18
19x28

Stranding

Nominal
Insulation
Thickness

Nominal
Jacket
Thickness

No. of Wires

inches

inches

inches

mm

Ibs/1000ft

kgs/km

49
49
49
49
133
133
259
259
259

0.070
0.070
0.070
0.070
0.070
0.070
0.080
0.080
0.080

0.125
0.125
0.155
0.155
0.155
0.170
0.190
0.205
0.220

0.92
0.95
1.13
1.26
1.36
1.55
1.81
1.94
2.24

23.4
24.1
28.7
32.0
34.5
39.4
46.0
49.3
56.9

557
623
818
1076
1308
1874
2694
3301
4701

829
927
1217
1601
1947
2789
4009
4913
6996

7x7
7x7
7x7
7x7
7x19
7x19
7x37
7x37
7x37

Nominal
O.D.

Approx.
Weight

ELECTRICAL AND MECHANICAL PARAMETERS


Conductor Size
Power

Grounding

AWG or MCM
6 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
4/0 AWG

10 AWG
6 AWG
5 AWG
4 AWG
3 AWG
1 AWG

Power
Conductor
Resistance
at 25C

Grounding
Conductor
Resistance
at 25C

Ground Check
Conductor
Resistance
at 25C

/1000Ft

/1000Ft

/1000Ft

mH/1000Ft

F/1000Ft

0.679

0.118
0.101
0.100
0.097
0.092
0.088

0.09
0.13
0.13
0.14
0.16
0.19

0.436
0.172
0.137
0.109
0.0868
0.0546

1.109
0.436
0.349
0.274
0.227
0.137

Ampacity(1)
40C
Ambient
Temp.

Maximum
Permissible
Tensile Force

kA

1.90
4.80
6.06
7.65
9.64
15.30

93
159
184
211
243
321

600
1500
1900
2400
3000
4800

Operating
Permissible ShortInductance
Capacitance per
Circuit
per unit length
unit length
Current(2) (1s)

(1) Ampacity- Free air measured; Based on continuous duty at 90C conductor temperature (2) Short-circuit current (1s) Based on conductor temperature from 90C up to 250C

STANDARD PRINT LEGEND:

TF CABLE (VOLTAGE) (SIZE) TYPE SHD-GC CSA LR 103932


FT1 FT5 (-40C) +90C P-07-KA060012-MSHA

16

www.tfcable.com

phone: 630-406-9000

SPECIAL FACTORY OPTIONS:


Jacket:
MSHA:
Jacket: TPU
MSHA:

Red, yellow, green, orange, blue


P-7K-268101 (CPE)
Red, yellow, green, orange, blue
P-07-KA030001 (TPU)

Issue 7.0, July 2015

5000V SHD-GC
Portable Power Cable Extra Heavy Duty EPR / NEO 90C MSHA
Mining Grade
SPECIFICATIONS & STANDARDS

ICEA S-75-381/NEMA WC58, ASTM B 172, ASTM B 33

CONSTRUCTION:

Conductors:

Conductor Shield:
Insulation:
Insulation Shield:
Color Code:
Grounding Cond:
Ground Check:
Cable Assembly:
Separator:
Jacket:

Flexible strand tinned copper conductor, ASTM B-172 and ICEA S-75-381, table 3-22
Extruded semi-conducting layer over conductor. ICEA S-75-381 sec. 3.14
Ethylene-propylene rubber (EPR) ICEA S-75-381, table 3-22
Non-conducting bedding tape and composite tinned copper/polyamide braid 60% minimum coverage
Polyamide braid color code - black, white, red, ICEA S-75-381
Tinned copper - ICEA S-75-381 Tab. 3-25
Yellow polypropylene-insulated tinned copper conductor, ICEA S-75-381 Tab. 3-22
Three power conductors, ground check and two non-insulated grounding conductors cabled together to form a round cable core
Single faced rubber-filled binder tape applied over core
Black, extra heavy duty, high torsion-resistant, integral-filled, reinforced Neoprene thermoset jacket, ICEA S-75-381 Tab. 3-3, 3-22, Sec. 3.21

FEATURES

APPLICATION

- For use as trailing mining cables.


- Use on AC off track equipment such as longwall & continuous miners, loaders, blast hole drillers,
conveyors, pumps and mobile equipment requiring grounding conductors and ground check
and metallic shielding overall.
- For use in applications where ground check conductor is required for added safety.
- Maximum continuous conductor temperature 90C

Excellent flexibility
Highly ozone, sun, weather, water and flame resistant
Rated and flexible at 40C
Excellent impact and abrasion resistant
Oil and heat resistant
Indent printed for easy identification

APPROVALS:

MSHA:

P-07-KA060012

Part
Number

SHDGC5KV4-3
SHDGC5KV2-3
SHDGC5KV1-3
SHDGC5KV1/0-3
SHDGC5KV2/0-3
SHDGC5KV4/0-3
SHDGC5KV350-3
SHDGC5KV500-3

Power
Conductor
Size

Power
Conductor
Stranding

Ground Check
Conductor
Size

Size

AWG or MCM

No. of Stranding

AWG

AWG

8
8
8
8
8
8
6
6

8
6
5
4
3
1
2/0
4/0

4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
4/0 AWG
350 MCM
500 MCM

259
259
259
266
342
532
888
1221

7x37
7x37
7x37
19x14
19x18
19x28
37x24
37x33

ELECTRICAL AND MECHANICAL PARAMETERS


Conductor Size
Power

Grounding

AWG or MCM
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
4/0 AWG
350 MCM
500 MCM

8 AWG
6 AWG
5 AWG
4 AWG
3 AWG
1 AWG
2/0 AWG
4/0 AWG

Stranding

Nominal
Insulation
Thickness

Nominal
Jacket
Thickness

No. of Wires

inches

inches

inches

mm

Ibs/1000ft

kgs/km

133 7x19
133 7x19
133 7x19
259 7x37
259 7x37
259 7x37
342 19x18
532 19x28

0.110
0.110
0.110
0.110
0.110
0.110
0.120
0.120

0.185
0.205
0.205
0.220
0.220
0.235
0.265
0.280

1.68
1.87
1.95
2.08
2.20
2.50
2.95
3.31

42.7
47.5
49.5
52.8
55.9
63.5
74.9
84.1

1769
2370
2660
3200
3615
5059
7700
10200

2633
3527
3959
4762
5380
7529
11458
15178

Grounding Conductor

Power
Conductor
Resistance
at 25C
/1000Ft

Grounding
Conductor
Resistance
at 25C
/1000Ft

Ground Check
Conductor
Resistance
at 25C
/1000Ft

0.274
0.172
0.137
0.109
0.0868
0.0546
0.0333
0.0233

0.697
0.436
0.349
0.274
0.227
0.137
0.0868
0.0546

0.679
0.679
0.679
0.679
0.679
0.679
0.436
0.436

Nominal
O.D.

Approx.
Weight

Inductance
per unit
length

Operating
Capacitance
per unit length

Permissible
Short-Circuit
Current(2) (1s)

Ampacity(1)
40C
Ambient Temp.

Maximum
Permissible
Tensile Force

mH/1000Ft

F/1000Ft

kA

0.107
0.101
0.100
0.097
0.092
0.088
0.081
0.078

0.11
0.13
0.13
0.14
0.16
0.19
0.24
0.28

3.03
4.80
6.06
7.65
9.64
15.30
25.31
36.18

122
159
184
211
243
321
435
536

950
1500
1900
2400
3000
4800
7900
11400

(1) Ampacity- Free air measured; Based on continuous duty at 90C conductor temperature (2) Short-circuit current (1s) Based on conductor temperature from 90C up to 250C

STANDARD PRINT LEGEND:

TF CABLE (VOLTAGE) (SIZE) TYPE SHD-GC


FT1 FT5 (-40C) +90C P-07-KA060012-MSHA

Issue 7.0, July 2015

SPECIAL FACTORY OPTIONS:


Jacket:
MSHA:
Jacket: TPU
MSHA:

Red, yellow, green, orange, blue


P-7K-268101 (CPE)
Red, yellow, green, orange, blue
P-07-KA030001 (TPU)

phone: 630-406-9000

www.tfcable.com

17

SHD-GC 5000V
Portable Power Cable Extra Heavy Duty EPR / NEO 90C CSA MSHA
Mining Grade

SPECIFICATIONS & STANDARDS

ICEA S-75-381/NEMA WC58, ASTM B 172, ASTM B 33, CSA C22.2 No. 96-09

CONSTRUCTION:

Conductors:
Conductor Shield:
Insulation:
Insulation Shield:
Color Code:
Grounding Cond:
Ground Check:
Cable Assembly:
Separator:
Jacket:

Flexible strand tinned copper, ASTM B 172 and ASTM B33, C22.2 No. 96-09 sec 5.3.1 table 3
Extruded semi-conducting layer over conductor. C22.2 No. 96-09
Ethylene-propylene rubber (EPR) C22.2 No. 96-09 sec 5.3.4 table 2 & 4
Non-conducting bedding tape and composite tinned copper/polyamide braid 60% minimum coverage
Polyamide braid color code - black, red, blue C22.2 No. 96-09 table 1
Tinned copper - C22.2 No. 96-09 sec 5.3.2
Yellow polypropylene-insulated tinned copper conductor, C22.2 No. 96-09 sec 5.3.3 table 4A
Three power conductors, ground check and two non-insulated grounding conductors cabled together to form a round cable core
Single faced rubber-filled binder tape applied over core
Black, extra heavy duty, high torsion-resistant, integral-filled, reinforced Neoprene thermoset jacket, C22.2 No. 96-09 sec 5.3.9 table 2 & 5

FEATURES

APPLICATION

- For use as trailing mining cables.


- Use on AC off track equipment such as longwall & continuous miners, loaders, blast hole drillers,
conveyors, pumps and mobile equipment requiring grounding conductors and ground check
and metallic shielding overall.
- For use in applications where ground check conductor is required for added safety.
- Maximum continuous conductor temperature 90C

Excellent flexibility
Highly ozone, sun, weather, water and flame resistant
Rated and flexible at 40C
Excellent impact and abrasion resistant
Oil and heat resistant
Indent printed for easy identification

APPROVALS:
CSA:
MSHA:

1523058 (LR 103932) - FT1; FT5; -40C +90C


P-07-KA060012

Part Number

SHDGC5KV6-3
SHDGC5KV4-3
SHDGC5KV2-3
SHDGC5KV1-3
SHDGC5KV1/0-3
SHDGC5KV2/0-3
SHDGC5KV3/0-3
SHDGC5KV4/0-3
SHDGC5KV250-3
SHDGC5KV350-3
SHDGC5KV500-3

Grounding Conductor

Power Conductor
Size

Power Conductor
Stranding

Ground Check
Conductor Size

Size

Stranding

Nominal Insulation
Thickness

Nominal Jacket
Thickness

AWG or MCM

No. of Stranding

AWG

AWG

No. of Wires

inches

inches

inches

mm

Ibs/1000 ft

kgs/km

8
8
8
8
8
8
8
8
6
6
6

10
9
7
6
5
4
3
2
1
1/0
3/0

49
133
133
133
259
259
259
259
266
342
532

7x7
7x19
7x19
7x19
7x37
7x37
7x37
7x37
19x14
19x18
19x28

0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.120
0.120
0.120

0.185
0.185
0.205
0.205
0.220
0.220
0.235
0.235
0.250
0.265
0.280

1.56
1.68
1.87
1.95
2.08
2.20
2.36
2.50
2.69
2.95
3.31

39.6
42.7
47.5
49.5
52.8
55.9
59.9
63.5
68.3
74.9
84.1

1460
1769
2370
2660
3200
3615
4300
5059
6200
7700
10200

2173
2633
3527
3959
4762
5380
6398
7529
9227
11458
15178

Permissible
Short-Circuit
Current(2) (1s)

Ampacity(1) 40C
Ambient
Temp.

6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 MCM
350 MCM
500 MCM

133
259
259
259
266
342
418
532
627
888
1221

7x19
7x37
7x37
7x37
19x14
19x18
19x22
19x28
19x33
37x24
37x33

Nominal O.D.

Approx. Weight

ELECTRICAL AND MECHANICAL PARAMETERS


Power-Grounding
Conductor Size

AWG or MCM

Power Conductor
Resistance at 20C

/1000Ft

6 AWG 10 AWG
4 AWG 8 AWG
2 AWG 6 AWG
1 AWG 5 AWG
1/0 AWG 4 AWG
2/0 AWG 3 AWG
3/0 AWG 2 AWG
4/0 AWG 1 AWG
250 MCM 1/0 AWG
350 MCM 2/0 AWG
500 MCM 4/0 AWG

0.436
0.274
0.172
0.137
0.109
0.0868
0.0688
0.0546
0.0466
0.0333
0.0233

Grounding Conductor
Resistance at 20C

Ground Check
Conductor
Resistance at 20C

Inductance
per unit length

Operating
Capacitance per
unit length

/1000Ft

/1000Ft

mH/1000Ft

F/1000Ft

kA

0.679
0.679
0.679
0.679
0.679
0.679
0.679
0.679
0.436
0.436
0.436

0.132
0.119
0.112
0.108
0.105
0.099
0.098
0.094
0.089
0.085
0.082

0.08
0.09
0.10
0.11
0.12
0.14
0.14
0.16
0.18
0.21
0.24

1.90
3.03
4.80
6.06
7.65
9.64
12.15
15.30
18.16
25.31
36.18

93
122
159
184
211
243
279
321
355
435
536

600
950
1500
1900
2400
3000
3800
4800
5800
7900
11400

1.109
0.697
0.436
0.349
0.274
0.227
0.172
0.137
0.109
0.0868
0.0546

(1) Ampacity- Free air measured; Based on continuous duty at 90C conductor temperature (2) Short-circuit current (1s) Based on conductor temperature from 90C up to 250C

STANDARD PRINT LEGEND:

TF CABLE (VOLTAGE) (SIZE) TYPE SHD-GC CSA


LR 103932 FT1 FT5 (-40C) +90C P-07-KA060012-MSHA
18

www.tfcable.com

phone: 630-406-9000

SPECIAL FACTORY OPTIONS:


Jacket:
MSHA:
Jacket: TPU
MSHA:

Red, yellow, green, orange, blue


P-7K-268101 (CPE)
Red, yellow, green, orange, blue
P-07-KA030001 (TPU)

Issue 7.0, July 2015

Maximum
Permissible
Tensile Force

8000V / 15000V SHD-GC


Portable Power Cable Extra Heavy Duty EPR / NEO 90C MSHA
Mining Grade

SPECIFICATIONS & STANDARDS

ICEA S-75-381/NEMA WC58, ASTM B 172, ASTM B 33

CONSTRUCTION:

Conductors:

Flexible strand tinned copper conductor, ASTM B-172 and ICEA S-75-381, table 3-22
Conductor Shield: Extruded semi-conducting layer over conductor. ICEA S-75-381 sec. 3.14
Insulation:
Ethylene-propylene rubber (EPR) ICEA S-75-381, table 3-22
Insulation Shield: Semi-conducting bedding tape and composite tinned copper/polyamide braid 60% minimum coverage
Color Code:
Polyamide braid color code - black, white, red, ICEA S-75-381
Grounding Cond: Tinned copper - ICEA S-75-381 Tab. 3-25
Ground Check:
Yellow polypropylene-insulated tinned copper conductor, ICEA S-75-381 Tab. 3-22
Cable Assembly:
Three power conductors, ground check and two non-insulated grounding conductors cabled together to form a round cable core
Separator:
Single faced rubber-filled binder tape applied over core
Jacket: 
Black, extra heavy duty, high torsion-resistant, integral-filled, reinforced Neoprene thermoset jacket, ICEA S-75-381 Tab. 3-3, 3-22, Sec. 3.21
FEATURES

APPLICATION

- For use as trailing mining cables.


- Use on AC off track equipment such as longwall & continuous miners, loaders, blast hole drillers,
conveyors, pumps and mobile equipment requiring grounding conductors and ground check
and metallic shielding overall.
- For use in applications where ground check conductor is required for added safety.
- Maximum continuous conductor temperature 90C

Excellent flexibility
Highly ozone, sun, weather, water and flame resistant
Rated and flexible at 40C
Excellent impact and abrasion resistant
Oil and heat resistant
Indent printed for easy identification

APPROVALS:

MSHA:

P-07-KA060012-1

Part
Number

Power
Conductor
Size

Power
Conductor
Stranding

Ground Check
Conductor
Size

AWG or MCM

No. of Stranding

SHDGC8KV1/0-3
SHDGC8KV2/0-3
SHDGC8KV4/0-3

1/0 AWG
2/0 AWG
4/0 AWG

266 19 x14
342 19 x18
532 19x28

SHDGC15KV2-3
SHDGC15KV1/0-3
SHDGC15KV2/0-3
SHDGC15KV4/0-3

2 AWG
1/0 AWG
2/0 AWG
4/0 AWG

259 7x37
266 19x14
342 19x18
532 19x28

Size

Stranding

Nominal
Insulation
Thickness

AWG

AWG

No. of Wires

inches

inches

inches

mm

Ibs/1000 ft

kgs/km

4
3
1

259
259
259

7x37
7x37
7x37

0.150
0.150
0.150

0.220
0.235
0.250

2.32
2.46
2.75

58.9
62.5
69.9

3530
4160
5590

5112
6191
8319

6
4
3
1

133
259
259
259

7x19
7x37
7x37
7x37

0.210
0.210
0.210
0.210

0.235
0.250
0.250
0.265

2.41
2.64
2.73
3.05

61.2
67.1
69.3
77.5

3505
4614
4895
6821

5216
6867
7285
10151

Grounding Conductor

Nominal
Jacket
Thickness

Nominal
O.D.

Approx.
Weight

ELECTRICAL AND MECHANICAL PARAMETERS


Power-Grounding
Conductor Size

Power
Conductor
Resistance
at 25C

Grounding
Conductor
Resistance
at 25C

Ground Check
Conductor
Resistance
at 25C

Inductance
per unit
length

Operating
Capacitance per
unit length

Permissible
Short-Circuit
Current(2) (1s)

Ampacity(1)
40C
Ambient
Temp.

Maximum
Permissible
Tensile Force

AWG or MCM

/1000Ft

/1000Ft

/1000Ft

mH/1000Ft

F/1000Ft

kA

2 AWG 6 AWG
1/0 AWG 4 AWG
2/0 AWG 3 AWG
4/0 AWG 1 AWG

0.172
0.109
0.0868
0.0546

0.679

0.122
0.113
0.107
0.101

0.09
0.10
0.11
0.13

4.80
7.65
9.64
15.30

159
211
243
321

1500
2400
3000
4800

0.436
0.274
0.227
0.137

(1) Ampacity- Free air measured; Based on continuous duty at 90C conductor temperature (2) Short-circuit current (1s) Based on conductor temperature from 90C up to 250C

STANDARD PRINT LEGEND:

TF CABLE (VOLTAGE) (SIZE) TYPE SHD-GC


FT1 FT5 (-40C) +90C P-07-KA060012-MSHA

Issue 7.0, July 2015

SPECIAL FACTORY OPTIONS:


Jacket:
MSHA:
Jacket: TPU
MSHA:

Red, yellow, green, orange, blue


P-7K-268101 (CPE)
Red, yellow, green, orange, blue
P-07-KA030001 (TPU)

phone: 630-406-9000

www.tfcable.com

19

SHD-GC 8000V / 15000V


Portable Power Cable Extra Heavy Duty EPR / NEO 90C CSA MSHA
Mining Grade

SPECIFICATIONS & STANDARDS

ICEA S-75-381/NEMA WC58, ASTM B 172, ASTM B 33, CSA C22.2 No. 96-09

CONSTRUCTION:

Conductors:

Conductor Shield:
Insulation:
Insulation Shield:
Color Code:
Grounding Cond:
Ground Check:
Cable Assembly:
Separator:
Jacket:

Flexible strand tinned copper, ASTM B 172 and ASTM B33, C22.2 No. 96-09 sec 5.3.1 table 3
Extruded semi-conducting layer over conductor. C22.2 No. 96-09
Ethylene-propylene rubber (EPR) C22.2 No. 96-09 sec 5.3.4 table 2 & 4
Semi-conducting bedding tape and composite tinned copper/polyamide braid 60% minimum coverage
Polyamide braid color code - black, red, blue C22.2 No. 96-09 table 1
Tinned copper - C22.2 No. 96-09 sec 5.3.2
Yellow polypropylene-insulated tinned copper conductor, C22.2 No. 96-09 sec 5.3.3 table 4A
Three power conductors, ground check and two non-insulated grounding conductors cabled together to form a round cable core
Single faced rubber-filled binder tape applied over core
Black, extra heavy duty, high torsion-resistant, integral-filled, reinforced Neoprene thermoset jacket, C22.2 No. 96-09 sec 5.3.9 table 2 & 5

FEATURES

APPLICATION

- For use as trailing mining cables.


- Use on AC off track equipment such as longwall & continuous miners, loaders, blast hole drillers,
conveyors, pumps and mobile equipment requiring grounding conductors and ground check
and metallic shielding overall.
- For use in applications where ground check conductor is required for added safety.
- Maximum continuous conductor temperature 90C

Excellent flexibility
Highly ozone, sun, weather, water and flame resistant
Rated and flexible at 40C
Excellent impact and abrasion resistant
Oil and heat resistant
Indent printed for easy identification

APPROVALS:
CSA:

MSHA:

1523058 (LR 103932) - FT1; FT5; -40C +90C


P-07-KA060012
Grounding
Conductor

Power
Conductor
Size

Power
Conductor
Stranding

Ground Check
Conductor
Size

Size

AWG or MCM

No. of Stranding

AWG

AWG

SHDGC8KV1-3CSA
SHDGC8KV1/0-3CSA
SHDGC8KV2/0-3CSA

1 AWG
1/0 AWG
2/0 AWG

259 7x37
266 19 x14
342 19 x18

SHDGC15KV4/0-3CSA

4/0 AWG

532 19x28

Part
Number

Stranding

Nominal
Insulation
Thickness

Nominal
Jacket
Thickness

No. of Wires

inches

inches

inches

mm

Ibs/1000 ft

kgs/km

6
5
4

133
259
259

7x19
7x37
7x37

0.150

0.220
0.220
0.235

2.21
2.32
2.46

56.0
58.9
62.5

3300
3530
4160

4911
5112
6191

259

7x37

0.210

0.265

3.05

77.5

6821

10151

Nominal
O.D.

Approx.
Weight

ELECTRICAL AND MECHANICAL PARAMETERS


Power-Grounding
Conductor Size

Power
Conductor
Resistance
at 25C

Grounding
Conductor
Resistance
at 25C

Ground Check
Conductor
Resistance
at 25C

Inductance
per unit
length

Operating
Capacitance per
unit length

Permissible
Short-Circuit
Current(2) (1s)

Ampacity(1)
40C
Ambient
Temp.

Maximum
Permissible
Tensile Force

AWG or MCM

/1000Ft

/1000Ft

/1000Ft

mH/1000Ft

F/1000Ft

kA

1 AWG - 5 AWG
1/0 AWG 4 AWG
2/0 AWG 3 AWG
4/0 AWG 1 AWG

0.137
0.109
0.0868
0.0546

0.679

0.117
0.113
0.107
0.101

0.09
0.10
0.11
0.13

6.06
7.65
9.64
15.30

184
211
243
321

1900
2400
3000
4800

0.349
0.274
0.227
0.137

(1) Ampacity- Free air measured; Based on continuous duty at 90C conductor temperature (2) Short-circuit current (1s) Based on conductor temperature from 90C up to 250C

STANDARD PRINT LEGEND:

TF CABLE (VOLTAGE) (SIZE) TYPE SHD-GC CSA LR 103932


FT1 FT5 (-40C) +90C P-07-KA060012-MSHA

20

www.tfcable.com

phone: 630-406-9000

SPECIAL FACTORY OPTIONS:


Jacket:
MSHA:
Jacket: TPU
MSHA:

Red, yellow, green, orange, blue


P-7K-268101 (CPE)
Red, yellow, green, orange, blue
P-07-KA030001 (TPU)

Issue 7.0, July 2015

300V SJOOW

Portable Cord -40C +90C UL CSA MSHA


Hard Usage - Medium Grade Mechanical Service

SPECIFICATIONS & STANDARDS


UL 62, CSA-C 22.2 No 49

CONSTRUCTION:

Conductors:

Flexible strand bare copper, ASTM B-174 and UL 62


Paper tape between conductor and insulation
EPR 90C compound class 3 table 8 UL 62
Insulated conductors cabled together: integral filled jacket
Talc for 18-10 AWG
Black CPE compound class, 90C + class 1.4, table 11, UL 62 integral fill
ICEA S-58-679, Method 1, table 1, black, white, green

Separator:
Insulation:
Assembly:
Separator:
Jacket:
Color code:
FEATURES

APPLICATION

- Excellent flexibility, resistance to oil, solvents, ozone, weather, sunlight


and water
- Flame test: meets VW-1, FT2, MSHA
- Temperature range: -40oC to +90oC
- Suitable for shallow water immersion

- Industrial and processing equipment, cranes and hoists, track systems, tools,
construction equipment, motors and associated machinery, garage portable
lights, battery charger and equipment exposed to oils, solvents, flame,
moisture and other electrical equipment

APPROVALS:
UL:
CSA:
MSHA:

E123366 (CPE)
1534535 (LL 103932) (CPE)
P-7K-254013 (CPE)

Part
Number

Conductor
Size

No. of
Conductors

AWG

Power
Conductor
Stranding

No. of Stranding

Nominal
Insulation
Thickness

inches

mm

Nominal Jacket
Thickness

Approx.
Weight

Ampacity (1)
30C
Ambient Temp.

mm

inches

mm

lbs/1000 ft

0.030

0.76

0.28
0.30
0.33

7.2
7.7
8.4

42
52
63

10.0
10.0
7.0

0.76

0.030

0.76

0.31
0.33
0.36

7.9
8.4
9.1

53
66
83

13.0
13.0
10.0

0.030

0.76

0.030

0.76

0.34
0.36
0.40

8.7
9.2
10.1

68
88
110

18.0
18.0
15.0

65 / 30

0.030

0.76

0.045

1.14

0.41
0.43
0.47

10.4
10.9
11.9

104
131
163

25.0
25.0
20.0

103 / 30

0.045

1.14

0.060

1.52

0.54
0.58
0.63

13.8
14.6
16.0

177
225
279

30.0
30.0
25.0

SJOOW18-2 IF
SJOOW18-3 IF
SJOOW18-4 IF

18

2
3
4

16 / 30

0.030

0.76

SJOOW16-2 IF
SJOOW16-3 IF
SJOOW16-4 IF

16

2
3
4

26 / 30

0.030

SJOOW14-2 IF
SJOOW14-3 IF
SJOOW14-4 IF

14

2
3
4

41 / 30

SJOOW12-2 IF
SJOOW12-3 IF
SJOOW12-4 IF

12

2
3
4

SJOOW10-2 IF
SJOOW10-3 IF
SJOOW10-4 IF

10

2
3
4

inches

Nominal O.D.

(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature

STANDARD PRINT LEGEND:


TF CABLE FLEXTREME (COND) (SIZE) (mm2) (UL) TYPE SJOOW E123366 90C SUN & WATER RES 300V CSA TYPE SJOOW 90C LL 103932 FT2
-40C P-7K-254013 MSHA

SPECIAL FACTORY OPTIONS:


Color jacket:

Yellow, Orange

Issue 7.0, July 2015

phone: 630-406-9000

www.tfcable.com

21

SOOW 600V
Portable Cord -40C +90C UL CSA MSHA
Extra Hard Usage - High Grade Mechanical Service

SPECIFICATIONS & STANDARDS


UL 62/CSA-C 22.2 No 49

CONSTRUCTION:

Conductors:
Insulation:
Assembly:
Separator:
Jacket:
Color code:

Flexible stranded bare copper, ASTM B-174 and UL 62


EPR compound, 90C compound class 3, table 8, UL 62
Insulated conductors cabled together with integral filled or rubber fillers
Talc for 18-10 AWG
Black CPE 90C compound class 1.4, table 22, UL 62
ICEA S-58-679, Method 1, table 1; black, white, red, green

FEATURES

APPLICATION

- Excellent flexibility, resistance to oil, solvents, ozone,


weather, sunlight and water
- Flame test meets VW-1, FT2, and MSHA
- Temperature range: -40oC to +90oC
- Suitable for shallow water immersion
- NEC Article 700 permitted use for specific applications.
- NFPA 70 permitted use in Hazardous Locations Classes I, II, III,
Divisions 1 & 2 as outlined in Articles 501, 502, 503 section 140.

- Industrial and processing equipment, cranes and hoists,


track systems, tools, construction equipment, motors and
associated machinery, garage portable lights, battery charger
and equipment exposed to oils, solvents, flame, moisture
and other electrical equipment

APPROVALS:

UL: E123366
CSA:
1534535 (LL 103932)
MSHA: P-7K-254013
Power
Conductor
Size

Part
Number

No. of
Conductors

AWG

Power
Conductor
Stranding

Nominal
Insulation
Thickness

Nominal
Jacket
Thickness

Nominal
O.D.

No. of Stranding

inches

mm

inches

mm

inches

mm

Ampacity (1)
30C
Ambient Temp.

lbs/1000 ft

SOOW18-2 IF
SOOW18-3 IF
SOOW18-4 IF

18

2
3
4

16 / 30

0.030

0.76

0.060

1.52

0.34
0.36
0.39

8.6
9.1
9.8

63
74
87

10.0
10.0
7.0

SOOW16-2 IF
SOOW16-3 IF
SOOW16-4 IF

16

2
3
4

26 / 30

0.030

0.76

0.060

1.52

0.37
0.39
0.42

9.3
10.1
10.5

76
90
107

13.0
13.0
10.0

SOOW14-2 IF
SOOW14-3 IF
SOOW14-4 IF

14

2
3
4

41 / 30

0.045

1.14

0.080

2.03

0.50
0.52
0.57

12.6
13.3
14.4

137
161
192

18.0
18.0
15.0

SOOW12-2 IF
SOOW12-3 IF
SOOW12-4 IF

12

2
3
4

65 / 30

0.045

1.14

0.095

2.41

0.57
0.59
0.64

14.4
15.2
16.5

184
217
261

25.0
25.0
20.0

SOOW10-2 IF
SOOW10-3 IF
SOOW10-4 IF

10

2
3
4

104 / 30

0.045

1.14

0.095

2.41

0.62
0.65
0.70

15.6
16.5
17.8

230
281
336

30.0
30.0
25.0

(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature

STANDARD PRINT LEGEND:

TF CABLE FLEXTREME (COND) (SIZE) (mm2) (UL) SOOW E123366 90C SUN & WATER RES 600V CSA SOOW 90C
LL 103932 FT2 -40C P-7K-254013 MSHA

SPECIAL FACTORY OPTIONS:


Color jacket:
SOOW/H07:
22

Approx.
Weight

Yellow, Orange
European harmonized dual rating

www.tfcable.com

phone: 630-406-9000

Issue 7.0, July 2015

600V SOOW

Power Cable -40C +90C UL CSA MSHA


Extra Hard Usage - High Grade Mechanical Service

SPECIFICATIONS & STANDARDS


UL 62/CSA-C 22.2 No 49

CONSTRUCTION:

Conductors:
Separator:
Insulation:
Assembly:
Separator:
Jacket:
Color code:

Stranded bare copper, ASTM B-173 and UL 62


Paper tape between conductor and insulation
EPR compound, 90C compound class 3, table 8, UL 62
Insulated conductors cabled together with integral filled or rubber fillers
Talc for 8-2 AWG
Black CPE 90C compound class 1.4, UL 62, table 15
ICEA S-58-679, Method 1, table 1; 2/c, 3/c - black, white, green; 4/c, 5/c - black, white, red, green, orange

FEATURES

APPLICATION

- Excellent flexibility, resistance to oil, solvents, ozone,


weather, sunlight and water
- Flame test meets VW-1, FT2, and MSHA
- Temperature range: -40oC to +90oC
- Suitable for shallow water immersion
- NEC Article 700 permitted use for specific applications.
- NFPA 70 permitted use in Hazardous Locations Classes I, II, III,
Divisions 1 & 2 as outlined in Articles 501, 502, 503 section 140.

- Industrial and processing equipment, cranes and hoists,


track systems, tools, construction equipment, motors and
associated machinery, garage portable lights, battery charger
and equipment exposed to oils, solvents, flame, moisture
and other electrical equipment

APPROVALS:

UL: E123366
CSA:
1534535 (LL 103932)
MSHA: P-7K-254013
Part
Number

Power
Conductor
Size

No. of
Conductors

Power
Conductor
Stranding

Nominal
Insulation
Thickness

No. and Diameter


inches
of Stranding

AWG

Nominal Jacket
Thickness

Nominal O.D.

Approx.
Weight

Ampacity (1)
30C
Ambient Temp.

mm

inches

mm

inches

mm

lbs/1000 ft

SOOW8-3 IF-UL/CSA
SOOW8-4 IF-UL/CSA
SOOW8-5 IF-UL/CSA

3
4
5

133 / 0.0156

0.060

1.52

0.110
0.125
0.125

2.79
3.18
3.18

0.83
0.93
1.00

21.1
23.5
25.4

452
577
683

40.0
35.0
28.0

SOOW6-3 IF-UL/CSA
SOOW6-4 IF-UL/CSA
SOOW6-5 IF-UL/CSA

3
4
5

184 / 0.0117

0.060

1.52

0.125
0.140
0.140

3.18
3.56
3.56

0.97
1.05
1.18

24.6
26.7
30.0

641
785
983

55.0
45.0
36.0

SOOW4-3 IF-UL/CSA
SOOW4-4 IF-UL/CSA
SOOW4-5 IF-UL/CSA

3
4
5

165 / 0.0156

0.060

1.52

0.140
0.155
0.155

3.56
3.94
3.94

1.13
1.25
1.31

28.7
31.8
33.2

913
1156
1318

70.0
60.0
48.0

SOOW2-3 IF-UL/CSA
SOOW2-4 IF-UL/CSA
SOOW2-5 IF-UL/CSA

3
4
5

262 / 0.0156

0.060

1.52

0.155
0.170
0.170

3.94
4.32
4.32

1.30
1.45
1.53

33.1
36.8
38.8

1287
1644
1900

95.0
80.0
64.0

(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature

STANDARD PRINT LEGEND:

TF CABLE FLEXTREME (COND) (SIZE) (mm2) (UL) SOOW E123366 90C SUN & WATER RES 600V CSA SOOW 90C
LL 103932 FT2 -40C P-7K-254013 MSHA

SPECIAL FACTORY OPTIONS:


Color jacket:
SOOW/H07:

Yellow, Orange
European harmonized dual rating

Issue 7.0, July 2015

phone: 630-406-9000

www.tfcable.com

23

SOOW 600V

Power Cable -40C +90C MSHA


Extra Hard Usage - High Grade Mechanical Service

SPECIFICATIONS & STANDARDS


UL 62/CSA-C 22.2 No 49

CONSTRUCTION:

Conductors:

Stranded bare copper, ASTM B-173 and UL 62


Paper tape between conductor and insulation
EPR compound, 90C compound class 3, table 8, UL 62
Insulated conductors cabled together with integral filled or rubber fillers
Polyester tape for 8-2 AWG
Black CPE 90C compound class 1.4, UL 62, table 15
ICEA S-58-679, Method 1, table 1; 2/c, 3/c - black, white, green; 4/c, 5/c - black, white, red, green, orange

Seprator:
Insulation:
Assembly:
Separator:
Jacket:
Color code:
FEATURES

APPLICATION

- Excellent flexibility, resistance to oil, solvents, ozone,


weather, sunlight and water
- Flame test meets VW-1, FT2, and MSHA
- Temperature range: -40oC to +90oC
- Suitable for shallow water immersion
- NEC Article 700 permitted use for specific applications.
- NFPA 70 permitted use in Hazardous Locations Classes I, II, III,
Divisions 1 & 2 as outlined in Articles 501, 502, 503 section 140.

- Industrial and processing equipment, cranes and hoists,


track systems, tools, construction equipment, motors and
associated machinery, garage portable lights, battery charger
and equipment exposed to oils, solvents, flame, moisture
and other electrical equipment

APPROVALS:

MSHA: P-7K-254013

Part
Number

Power
Conductor
Size

No. of
Conductors

No. and Diameter


of Stranding

AWG
SOOW8-2 IF
SOOW8-3 IF
SOOW8-4 IF
SOOW8-5 IF
SOOW6-2 IF
SOOW6-3 IF
SOOW6-4 IF
SOOW6-5 IF
SOOW4-2
SOOW4-3
SOOW4-4
SOOW4-5
SOOW2-2
SOOW2-3
SOOW2-4
SOOW2-5

Power
Conductor
Stranding

2
3
4
5

2
3
4
5

2
3
4
5

2
3
4
5

133 / 0.0156

184 / 0.0117

165 / 0.0156

262 / 0.0156

Nominal
Insulation
Thickness
inches

0.050

0.050

0.050

0.050

mm

Nominal
Jacket
Thickness
inches

Nominal
O.D.

Approx.
Weight

Ampacity (1)
30C
Ambient Temp.

mm

inches

mm

lbs/1000 ft

16.1
17.1
18.8
20.7

258
326
410
499

40
40
35
28

1.27

0.060

1.52

0.64
0.68
0.74
0.81

1.27

0.060
0.060
0.080
0.080

1.52
1.52
2.03
2.03

0.72
0.77
0.89
0.97

18.4
19.5
22.5
24.7

353
450
607
736

55
55
45
36

2.03

0.88
0.94
1.03
1.13

22.4
23.8
26.1
28.8

540
689
876
1068

70
70
60
48

2.03

1.01
1.07
1.18
1.30

25.6
27.3
30.0
33.1

755
980
1251
1534

95
95
80
64

1.27

1.27

0.080

0.080

(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature

STANDARD PRINT LEGEND:

TF CABLE FLEXTREME (COND) (SIZE) (mm2) TYPE SOOW 600V SUNLIGHT & WATER RESISTANT 90C P-7K-254013-MSHA

24

www.tfcable.com

phone: 630-406-9000

Issue 7.0, July 2015

600V SOOW

Control Cable -40C +90C UL CSA MSHA


Extra Hard Usage - High Grade Mechanical Service
SPECIFICATIONS & STANDARDS

UL 62/CSA-C 22.2 No 49

CONSTRUCTION:

Conductors:

Flexible stranded bare copper, ASTM B-174 and UL 62


EPR compound, 90C class 3, table 8, UL 62
Insulated conductors cabled together
Polyester tape for 18-10 AWG
Black CPE compound class, 90C + class 1.4, table 11, UL 62
ICEA S-58-679, Method 1, table 1

Insulation:
Assembly:
Separator:
Jacket:
Color code:
FEATURES

APPLICATION

- Excellent flexibility, resistance to oil, solvents, ozone,


weather, sunlight and water
- Flame test meets VW-1, FT2, and MSHA
- Temperature range: -40oC to +90oC
- Suitable for shallow water immersion
- NEC Article 700 permitted use for specific applications.
- NFPA 70 permitted use in Hazardous Locations Classes I, II, III,
Divisions 1 & 2 as outlined in Articles 501, 502, 503 section 140.

- Industrial and processing equipment, cranes and hoists,


track systems, tools, construction equipment, motors and
associated machinery, garage portable lights, battery charger
and equipment exposed to oils, solvents, flame, moisture
and other electrical equipment

APPROVALS:

UL: E123366
CSA:
1534535 (LL 103932)
MSHA: P-7K-254013
Part
Number
SOOW18-5
SOOW18-6
SOOW18-7
SOOW18-8
SOOW18-10
SOOW18-12
SOOW18-14
SOOW18-16
SOOW18-20
SOOW18-24
SOOW18-30
SOOW16-5
SOOW16-6
SOOW16-7
SOOW16-8
SOOW16-9
SOOW16-10
SOOW16-12
SOOW16-14
SOOW16-16
SOOW16-20
SOOW16-24
SOOW16-30
SOOW16-37
SOOW16-40
SOOW16-52
SOOW16-60
SOOW14-5
SOOW14-6
SOOW14-7
SOOW14-8
SOOW14-10
SOOW14-12
SOOW14-16
SOOW14-20
SOOW14-24
SOOW14-30
SOOW14-37

Power
Conductor
Size
AWG

No. of
Conductors

18

5
6
7
8
10
12
14
16
20
24
30

16

5
6
7
8
9
10
12
14
16
20
24
30
37
40
52
60

14

5
6
7
8
10
12
16
20
24
30
37

Power
Conductor
Stranding
No. of Stranding

16 / 30

26 / 30

41 / 30

Nominal
Insulation
Thickness
inches
mm

0.030

0.030

0.045

inches

mm

inches

mm

lbs/1000 ft

Ampacity (1)
30C
Ambient Temp.
A

0.76

0.080
0.080
0.080
0.080
0.080
0.080
0.095
0.095
0.095
0.095
0.110

2.03
2.03
2.03
2.03
2.03
2.03
2.41
2.41
2.41
2.41
2.79

0.46
0.48
0.48
0.52
0.59
0.61
0.66
0.69
0.76
0.83
0.91

11.7
12.3
12.3
13.1
15.0
15.4
16.9
17.6
19.3
21.2
23.0

123
131
134
151
180
202
246
274
333
376
470

5.6
5.6
5.6
4.9
4.9
3.5
3.5
3.5
3.5
3.2
3.2

0.76

0.080
0.080
0.080
0.080
0.095
0.095
0.095
0.095
0.095
0.095
0.110
0.110
0.110
0.110
0.125
0.125

2.03
2.03
2.03
2.03
2.41
2.41
2.41
2.41
2.41
2.41
2.79
2.79
2.79
3.18
3.18
3.18

0.49
0.53
0.53
0.56
0.68
0.68
0.70
0.73
0.76
0.84
0.95
1.00
1.07
1.18
1.28
1.35

12.5
13.4
13.4
14.3
17.2
17.2
17.7
18.5
19.4
21.2
24.1
25.4
27.3
29.9
32.4
34.2

149
165
170
193
238
251
282
316
354
434
520
615
730
843
1016
1154

8.0
8.0
8.0
7.0
7.0
7.0
5.0
5.0
5.0
5.0
4.5
4.5
4.0
4.0
3.5
3.5

1.14

0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.010
0.010
0.125
0.125

2.41
2.41
2.41
2.41
2.41
2.41
2.41
2.79
2.79
3.18
3.18

0.64
0.69
0.69
0.74
0.86
0.89
0.98
1.11
1.22
1.32
1.42

16.4
17.6
17.6
18.9
21.9
22.5
24.8
28.1
31.1
33.6
36.2

251
277
285
324
388
441
563
730
828
1027
1224

12.0
12.0
12.0
10.5
10.5
7.5
7.5
7.5
6.8
6.8
6.0

Nominal Jacket
Thickness

Nominal
O.D.

Approx.
Weight

(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature

STANDARD PRINT LEGEND:

SPECIAL FACTORY OPTIONS:


TF CABLE CONTROLFLEX (COND) (SIZE) (mm2) (UL) TYPE SOOW E123366 90C SUN Color jacket:
& WATER RES 600V CSA TYPE SOOW 90C LL 103932 FT2 -40C P-7K-254013 MSHA
SOOW/H07:
Issue 7.0, July 2015

phone: 630-406-9000

Yellow, orange
European harmonized dual rating
www.tfcable.com

25

SOOW 600V
Control Cable -40C +90C UL CSA MSHA
Extra Hard Usage - High Grade Mechanical Service

SPECIFICATIONS & STANDARDS

UL 62/CSA-C 22.2 No 49

CONSTRUCTION:

Conductors:

Flexible stranded bare copper, ASTM B-174 and UL 62


EPR compound, 90C + class 3, table 8, UL 62
Insulated conductors cabled together
Polyester tape for 18-10 AWG
Black CPE compound class, 90C + class 1.4, table 11, UL 62 integral fill
ICEA S-58-679, Method 1, table 1

Insulation:
Assembly:
Separator:
Jacket:
Color code:
FEATURES

APPLICATION

- Excellent flexibility, resistance to oil, solvents, ozone,


weather, sunlight and water
- Flame test meets VW-1, FT2, and MSHA
- Temperature range: -40oC to +90oC
- Suitable for shallow water immersion
- NEC Article 700 permitted use for specific applications.
- NFPA 70 permitted use in Hazardous Locations Classes I, II, III,
Divisions 1 & 2 as outlined in Articles 501, 502, 503 section 140

- Industrial and processing equipment, cranes and hoists,


track systems, tools, construction equipment, motors and
associated machinery, garage portable lights, battery charger
and equipment exposed to oils, solvents, flame, moisture
and other electrical equipment

APPROVALS:

UL: E123366
CSA:
1534535 (LL 103932)
MSHA: P-7K-254013
Part
Number

Power
Conductor
Size

No. of
Conductors

AWG
SOOW12-5
SOOW12-6
SOOW12-7
SOOW12-8
SOOW12-9
SOOW12-10
SOOW12-12
SOOW12-14
SOOW12-16
SOOW12-20
SOOW12-24
SOOW12-26
SOOW12-30
SOOW12-37
SOOW12-44
SOOW10-5
SOOW10-6
SOOW10-7
SOOW10-8
SOOW10-10
SOOW10-12
SOOW10-16
SOOW10-20
SOOW10-26
SOOW10-30
SOOW10-40

Power
Conductor
Stranding

No. of Stranding

12

5
6
7
8
9
10
12
14
16
20
24
26
30
37
44

10

5
6
7
8
10
12
16
20
26
30
40

65 / 30

103 / 30

Nominal
Insulation
Thickness

inches

0.045

0.045

Nominal Jacket
Thickness

Nominal
O.D.

Approx.
Weight

Ampacity (1)
30C
Ambient Temp.

mm

inches

mm

inches

mm

lbs/1000 ft

1.14

0.095
0.095
0.095
0.095
0.095
0.110
0.110
0.110
0.110
0.125
0.125
0.125
0.125
0.125
0.125

2.41
2.41
2.41
2.41
2.41
2.79
2.79
2.79
2.79
3.18
3.18
3.18
3.18
3.18
3.18

0.70
0.74
0.74
0.80
0.92
0.95
0.98
1.03
1.08
1.22
1.35
1.38
1.43
1.53
1.72

17.8
18.8
18.8
20.2
23.5
24.2
24.9
26.1
27.5
31.0
34.3
35.0
36.3
39.0
43.6

319
344
358
408
461
519
591
668
755
971
1106
1180
1327
1588
1868

1.14

0.095
0.095
0.095
0.095
0.110
0.110
0.125
0.125
0.125
0.125
0.141

2.41
2.41
2.41
2.41
2.79
2.79
3.18
3.18
3.18
3.18
3.58

0.76
0.82
0.82
0.88
1.05
1.09
1.23
1.35
1.54
1.59
1.87

19.3
20.7
20.7
22.3
26.8
27.6
31.2
34.4
39.0
40.4
47.4

409
452
474
541
686
788
1053
1304
1598
1803
2464

(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature

SPECIAL FACTORY OPTIONS:

STANDARD PRINT LEGEND:


TF CABLE CONTROLFLEX (COND) (SIZE) (mm2) (UL) TYPE SOOW E123366 90C SUN Color jacket:
& WATER RES 600V CSA TYPE SOOW 90C LL 103932 FT2 -40C P-7K-254013 MSHA SOOW/H07:
26

www.tfcable.com

phone: 630-406-9000

Yellow, orange
European harmonized dual rating

Issue 7.0, July 2015

16.0
16.0
16.0
14.0
14.0
14.0
10.0
10.0
10.0
10.0
9.0
9.0
9.0
8.0
7.0
20.0
20.0
20.0
17.5
17.5
12.5
12.5
12.5
11.3
11.3
10.0

600V SOOW

Portable Cord -50C +105C UL CSA


Extra Hard Usage - High Grade Mechanical Service

SPECIFICATIONS & STANDARDS


UL 62/CSA-C 22.2 No 49

CONSTRUCTION:

Conductors:
Insulation:
Assembly:
Separator:
Jacket:
Color code:

Stranded annealed bare copper, ASTM B-174 and UL 62


EPR 105C compound class 19, table 8, UL 62
Insulated conductors cabled together
Polyester tape for 18-10 AWG
Yellow CPE 105C compound class 1.12, table 11, UL 62
ICEA S-58-679, Method 1, table 1; 3/c - black, white, green; 4/c - black, white, red, green

FEATURES

APPLICATION

- Excellent flexibility in cold temperatures, resistance to oils,


acids, chemicals, solvents, ozone, weather and water
- Flame test meets VW-1, FT2, MSHA
- Temperature range: -50C to +105 C
- For Indoor and outdoor use
- NEC Article 700 permitted use for specific applications.
- NFPA 70 permitted use in Hazardous Locations Classes I, II, III,
Divisions 1 & 2 as outlined in Articles 501, 502, 503 section 140

- Industrial and processing equipment, cranes and hoists,


track systems, tools, construction equipment, motors and
associated machinery, garage portable lights, battery charger
and equipment exposed to oils, solvents, flame, moisture
and other electrical equipment

APPROVALS:
UL: E123366
CSA:
1534535 (LL 103932)
Part
Number

Power
Conductor
Size

No. of
Conductors

AWG

Power
Conductor
Stranding

Nominal
Insulation
Thickness

Nominal
Jacket
Thickness

Nominal
O.D.

Approx.
Weight

Ampacity (1)
30C
Ambient Temp.
A

No. of Stranding

inches

mm

inches

mm

inches

mm

lbs/1000 ft

SOOW18-3 IF-105C-YEL
SOOW18-4 IF-105C-YEL

18

3
4

16 / 30

0.030

0.76

0.060

1.52

0.36
0.39

9.1
9.8

74
87

10.0
7.0

SOOW16-3 IF-105C-YEL
SOOW16-4 IF-105C-YEL

16

3
4

26 / 30

0.030

0.76

0.060

1.52

0.39
0.42

10.1
10.5

90
107

13.0
10.0

SOOW14-3 IF-105C-YEL
SOOW14-4 IF-105C-YEL

14

3
4

41 / 30

0.045

1.14

0.080

2.03

0.52
0.57

13.3
14.4

161
192

18.0
15.0

SOOW12-3 IF-105C-YEL
SOOW12-4 IF-105C-YEL

12

3
4

65 / 30

0.045

1.14

0.095

2.41

0.59
0.64

15.2
16.5

217
261

25.0
20.0

SOOW10-3 IF-105C-YEL
SOOW10-4 IF-105C-YEL

10

3
4

103 / 30

0.045

1.14

0.095

2.41

0.65
0.70

16.5
17.8

281
336

30.0
25.0

(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature

STANDARD PRINT LEGEND:


TF CABLE SUPER FLEXTREME (COND) (SIZE) (mm2) (UL) TYPE SOOW E123366 105C SUN & WATER RES 600V CSA SOOW 105C LL
103932 FT2 -50C

Issue 7.0, July 2015

phone: 630-406-9000

www.tfcable.com

27

H07RN-F 750V SOOW / 600V

Portable Cord -40C +90C UL CSA MSHA <HAR>


Extra Hard Usage - High Grade Mechanical Service

SPECIFICATIONS & STANDARDS


UL 62/HD 22.154

CONSTRUCTION:

Conductors:
Separator:
Insulation:
Assembly:
Separator:
Jacket:
Color code:

Stranded bare copper with ASTM B 174 and UL 62; IEC 60228
Paper tape for 12-8 AWG
EPR 90C compound class 3, table 8, HD 22.154 and UL 62
Insulated conductors are assembled round
Polyester tape for 18-8 AWG
Black CPE 90C compound class 1.4, table 11, HD 22.154, UL 62, integral fill jacket
HD 308, DIN VDE 0293-308; 3/c: green/yellow, blue, brown; 4/c: green/yellow, brown, black, grey;

FEATURES

APPLICATION

- Industrial and processing equipment, cranes and hoists, track systems, tools,
construction equipment, motors and associated machinery, garage portable
lights, battery
charger and equipment exposed to oils, solvents, flame, moisture and other
electrical equipment.

Sunlight, water, solvents, ozone, weather and oil resistance


Temperature range: -40C to +90C
Flame test VW-1 FT2 and MSHA
Suitable for shallow water immersion

APPROVALS:



UL:
CSA:
MSHA:
BBJ:

E123366
1534535 (LL 103932)
P-7K-254013
<HAR>

Part
Number

Conductor
No. of
Size
Conductors
AWG

Power
Conductor
Stranding
No. of Stranding

Nominal Insulation
Thickness
inches

Nominal Jacket
Thickness

mm

Nominal O.D.

Approx.
Weight

Ampacity (1)
30C
Ambient Temp.
A

inches

mm

inches

mm

lbs/1000 ft

SOOW/H07RN-F18-3
SOOW/H07RN-F18-4

18

3/C
4/C

30 / 0.197

0.032 / 0.030 0.81 / 0.76

0.063 / 0.060
0.085 / 0.080

1.60 / 1.52
2.16 / 2.03

0.400
0.476

10.2
12.1

84
96

7.0
5.6

SOOW/H07RN-F16-3
SOOW/H07RN-F16-4

16

3/C
4/C

30 / 0.248

0.032 / 0.030 0.81 / 0.76

0.070 / 0.067
0.085 / 0.080

1.78 / 1.70
2.16 / 2.03

0.449
0.516

11.4
13.1

99
125

10.0
8.0

SOOW/H07RN-F14-3
SOOW/H07RN-F14-4

14

3/C
4/C

47 / 0.248

0.047 / 0.045 1.19 / 1.14

0.085 / 0.080

2.16 / 2.03
2.54 / 2.41

0.594
0.671

15.1
17.0

183
216

15.0
12.0

SOOW/H07RN-F12-3
SOOW/H07RN-F12-4

12

3/C
4/C

51 / 0.297

0.047 / 0.045 1.19 / 1.14

0.100 / 0.095

2.54 / 2.41

0.681
0.736

17.3
18.7

249
300

20.0
16.0

SOOW/H07RN-F10-3
SOOW/H07RN-F10-4

10

3/C
4/C

77 / 0.297

0.047 / 0.045 1.19 / 1.14

0.100 / 0.095

2.54 / 2.41

0.724
0.791

18.4
20.1

304
366

25.0
20.0

SOOW/H07RN-F8-3
SOOW/H07RN-F8-4

3/C
4/C

74 / 0.397

0.062 / 0.060 1.57 / 1.52

0.125 / 0.120

3.43 / 3.30
3.56 / 3.43

0.902
0.984

22.9
25.0

537
651

40.0
35.0

(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature

STANDARD PRINT LEGEND:


TF CABLE FLEXTREME (COND) (SIZE) (mm2) (UL) SOOW E123366 90C SUN & WATER RES 600V CSA SOOW 90C LL 103932 FT2 -40C
P-7K-254013 MSHA TF KABLE 3 BBJ <HAR> H07RN-F ROHS

28

www.tfcable.com

phone: 630-406-9000

Issue 7.0, July 2015

600V SC-STAGE LIGHTING CABLE

Portable Power Cable 105C UL C(UL)


Industrial Grade

SPECIFICATIONS & STANDARDS


UL 62 / UL1581, CSA-C 22.2 No 96

CONSTRUCTION:
Conductors:
Separator:
Jacket:

Flexible strand bare copper, ASTM B 172 class K


Paper tape over conductor
Black heavy duty EPR / CPE two layers bonded thermoset jacket, oil resistant and flame retardant

FEATURES

APPLICATION

- For use in accordance with NEC Articles 520, 525 and 530,
indoor and outdoor locations
- Flame test: meets VW-1, MSHA
- Excellent flexibility, resistance to oil, solvents, ozone, aging and abrasion
- Suitable for continuous submersion in water
- Temperature range: -35C to +105C

- P
 ortable power and lighting applications in the entertainment industry
including motion picture, television, theatres, stages and similar locations

APPROVALS:
UL:
C(UL):

Part
Number

STAGE6
STAGE4
STAGE2
STAGE1
STAGE1/0
STAGE2/0
STAGE3/0
STAGE4/0
STAGE6-GRN

E228208 (UL); -35C; Oil resistant 60C; Water Resistant


E207132 FT5; 105C; 600V; Oil Resistant
Power
Conductor
Size

Power
Conductor
Stranding

AWG

Nominal Jacket
Thickness

Nominal O.D.

Approx. Weight

Ampacity(1)

No. of Stranding

inches

mm

inches

mm

lbs/1000 ft

kgs/km

6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG

258 / 30
410 / 30
649 / 30
815 / 30
1032 / 30
1287 / 30
1622 / 30
2052 / 30

0.095
0.095
0.106
0.136
0.136
0.136
0.136
0.136

2.41
2.41
2.69
3.45
3.45
3.45
3.45
3.45

0.371
0.430
0.509
0.611
0.672
0.697
0.777
0.803

9.4
10.9
12.9
15.5
17.1
17.7
19.7
20.4

131
189
285
379
463
549
674
814

195
282
424
564
689
816
1003
1212

105
140
190
220
260
300
350
405

6 AWG

258 / 30

0.095

2.41

0.371

9.4

131

195

105

(1) Ampacities are based on single conductor in free air, 30C ambient air temperature 90C conductor operating temperature per Table 400-5 (B) of the 2008 NEC

STANDARD PRINT LEGEND:

TF CABLE (UL) E228208 (SIZE) TYPE SC 105C -35C MAX AMPS NEC TABLE 400-5B
FOR 90C 600V WATER RES. OIL RES. 60C E207132 C(UL) TYPE PPC FT5

Issue 7.0, July 2015

phone: 630-406-9000

www.tfcable.com

29

RHH / RHW-2 / USE-2 600V

Portable Power Cable 90C UL


Industrial Grade

SPECIFICATIONS & STANDARDS


ICEA S-95-658/NEMA WC 70, UL 44, UL 854, ASTM B 8, ASTM B 33

CONSTRUCTION:

Conductor:
Separator:
Insulation:
Jacket:

Tinned copper stranding Class B, ASTM B-8, ASTM B-33


Tape separator between the conductor and insulation
Ethylene-propylene rubber (EPR)
Black heavy duty, CPE thermoset compound, UL 44, UL 854, ICEA S-95-658

FEATURES

APPLICATION

- UL listed RHH/RHW-2/USE-2
- Rated 90C dry and wet
- Ozone, sunlight, oil, grease, weather, water, chemical
and abrasion resistant
- VW-1, SUN RES, FOR CT USE for black
jacket sizes 1/0 AWG and larger

- Designed for uses requiring a heavy duty power cable


- For portable and or fixed installations
- Leads for motors, generators, batteries, jumper cables

APPROVALS:
UL:
E232192 - EPR / CPE RHW-2 90C wet or dry, Sunlight resistant VW-1 for CT use 1/0 & larger

Part
Number

USE2-14
USE2-12
USE2-10
USE2-8
USE2-6
USE2-4
USE2-2
USE2-1/0
USE2-2/0
USE2-4/0
USE2-250
USE2-350
USE2-500
USE2-750
USE2-1000
USE2-8-GRN
USE2-6-WHT
USE2-6-RED

Power
Conductor
Size

Power
Conductor
Stranding

Conductor
Diameter

Nominal
Insulation
Thickness

Nominal
Jacket
Thickness

AWG
or MCM

No. and Dia.


of Stranding

inches

inches

inches

14 AWG
12 AWG
10 AWG
8 AWG
6 AWG
4 AWG
2 AWG
1/0 AWG
2/0 AWG
4/0 AWG
250 MCM
350 MCM
500 MCM
750 MCM
1000 MCM

7x0.024
7x0.031
7x0.039
7x0.048
7x0.061
7x0.077
7x0.097
19x0.074
19x0.084
19x0.106
37x0.082
37x0.097
37x0.116
61x0.111
61x0.128

0.072
0.091
0.116
0.146
0.183
0.231
0.292
0.373
0.419
0.528
0.575
0.681
0.813
0.980
1.152

0.030
0.030
0.030
0.045
0.045
0.045
0.045
0.055
0.055
0.055
0.065
0.065
0.065
0.080
0.080

8 AWG
6 AWG
6 AWG

7x0.048
7x0.061
7x0.061

0.146
0.183
0.183

0.045

Ampacity(1)
Approx.
40C
Weight Ambient Temp.

Cable Diameter
Minimum

Approx.

Maximum

inches

mm

inches

mm

inches

mm

Ibs/
1000 ft

0.015
0.015
0.015
0.015
0.030
0.030
0.030
0.045
0.045
0.045
0.065
0.065
0.065
0.065
0.065

0.161
0.185
0.205
0.268
0.335
0.382
0.441
0.559
0.602
0.717
0.827
0.929
1.055
1.264
1.413

4.10
4.70
5.20
6.80
8.50
9.70
11.20
14.20
15.30
18.20
21.00
23.60
26.80
32.10
35.90

0.165
0.189
0.213
0.276
0.346
0.394
0.453
0.575
0.619
0.736
0.850
0.957
1.088
1.303
1.457

4.20
4.80
5.40
7.00
8.80
10.0
11.50
14.60
15.73
18.70
21.60
24.30
27.64
33.10
37.0

0.177
0.205
0.228
0.299
0.374
0.425
0.488
0.622
0.669
0.795
0.917
1.031
1.177
1.406
1.575

4.50
5.20
5.80
7.60
9.50
10.80
12.40
15.80
17.00
20.20
23.30
26.20
29.90
35.70
40.00

24
34
49
79
124
179
260
420
513
774
956
1290
1798
2686
3463

25
32
47
83
109
145
192
258
298
400
445
552
695
898
1076

0.015
0.030
0.030

0.268
0.335
0.335

6.80
8.50
8.50

0.276
0.346
0.346

7.00
8.80
8.80

0.299
0.374
0.374

7.60
9.50
9.50

79
124
124

83
109
109

(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature

STANDARD PRINT LEGEND:





1 AWG AND SMALLER:


TF CABLE E232192 (UL) TYPE USE-2 E193954 RHH / RHW-2 (SIZE) EP/CPE 600V VW-1 SUN RES
1/0 AWG AND LARGER:
TF CABLE E232192 (UL) TYPE USE-2 E193954 RHH / RHW-2 (SIZE) EP/CPE 600V VW-1 SUN RES FOR CT USE

30

www.tfcable.com

phone: 630-406-9000

Issue 7.0, July 2015

600V ARC - WELDING CABLE

Zero Halogen EP Welding Cable 105C


Industrial Grade

CONSTRUCTION:

Conductors:

Separator:
Jacket:
Color of jacket:

Flexible stranded bare copper per ASTM B-172 Class K


Tape separator between the conductor and insulation
Ethylene Propylene Rubber (EPR) Class 45, 105C Table 50.55 of UL 1581
Black 6AWG - 500MCM;
Red 6AWG4/0

FEATURES

APPLICATION

- Secondary voltage resistance welding leads


- Leads for motors, generators, batteries

Excellent flexibility
Ozone, sun, weather resistant
Rated and flexible at 40C
Oil resistant
Heat resistant at 105C

Part
Number

WC6
WC4
WC2
WC1
WC1/0
WC2/0
WC3/0
WC4/0
WC250
WC350
WC500
WC6-RED
WC4-RED
WC2-RED
WC1-RED
WC1/0-RED
WC2/0-RED
WC3/0-RED
WC4/0-RED

Maximum
Direct Current
Resistance
20C /km

Power
Conductor
Size

Power
Conductor
Stranding

Nominal
Insulation
Thickness

AWG or MCM

No. of Stranding

inches

inches

mm

Ibs/1000 ft

kgs/km

/km

6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 MCM
350 MCM
500 MCM

253/30
403/30
636/30
798/30
1016/30
1261/30
1590/30
2007/30
2399/30
3327/30
4746/30

0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.095
0.095
0.095

0.319
0.366
0.429
0.508
0.555
0.598
0.673
0.716
0.866
0.953
1.130

8.1
9.3
10.9
12.9
14.1
15.2
17.1
18.2
22.0
24.2
28.7

115
169
255
303
396
482
595
734
907
1203
1734

171
252
379
451
589
719
887
1092
1349
1790
2580

1.38
0.865
0.549
0.436
0.345
0.276
0.219
0.173
0.147
0.106
0.0743

133
179
237
284
327
377
449
514
577
719
908

6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG

253/30
403/30
636/30
798/30
1016/30
1261/30
1590/30
2007/30

0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080

0.319
0.366
0.429
0.508
0.555
0.598
0.673
0.716

8.1
9.3
10.9
12.9
14.1
15.2
17.1
18.2

115
169
255
303
396
482
595
734

171
252
379
451
589
719
887
1092

1.38
0.865
0.549
0.436
0.345
0.276
0.219
0.173

133
179
237
284
327
377
449
514

Nominal
O.D.

Approx.
Weight

Ampacity
40C Ambient
Temp.

(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature

STANDARD PRINT LEGEND:

TF CABLE (SIZE) ARC WELDING CABLE 600V OIL RESISTANT -40C +105C

SPECIAL FACTORY OPTIONS:

Conductor:
Class M (AWG 34) stranding
Jacket:
Neoprene
CSA: 1101275 -FT2; Oil Resistant (Optional)
Neoprene is a registered trademark of DuPont

Issue 7.0, July 2015

phone: 630-406-9000

www.tfcable.com

31

REMOTE & DRILL CORD 600V

Remote & Drill Cord Cable -40C +90C MSHA


Mining Grade
SPECIFICATIONS & STANDARDS

ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC 70, ASTM B-3/B174

CONSTRUCTION:
Conductors:
Separator:
Insulation:
Assembly:
Jacket:
Color Code:

Stranded bare copper in accordance with ASTM B-3/B-174


Paper or polyester tape
EPR 90C thermoset compound, ICEA S-95-658
Insulated conductors cabled together with rubber fillers as needed.
Black heavy duty double layer reinforced Neoprene ICEA S-75-381 table 3-3, 3-22 sec 3.21
ICEA S-58-679, method 1 table 1; black, white, red, green, orange

FEATURES

APPLICATION

- Heavy duty applications and long service life in wet or dry


locations in underground mines

Sunlight, water, solvents, ozone, weather and oil resistance


Heavy duty abrasion
Tear and crush resistance
Flame test: MSHA
Temperature range: -40C to +90C

APPROVALS: MSHA: 07-KA050015-MSHA


Part
Number

Power
Conductor
Size

No. of
Conductors

AWG
DC10-5

10

Nominal
Insulation
Thickness

Power
Conductor Stranding

Nominal
Jacket
Thickness

Nominal
O.D.

Approx.
Weight

Ampacity (1)
40C
Ambient Temp.

No. and Diameter of Stranding

inches

mm

inches

mm

inches

mm

Ibs./1000 ft.

104 / 0.01

0.045

1.14

0.155

3.94

0.91

23.1

545

20.0

(1) Ampacity Free air measured; Based on continuous duty at 90C conductor temperature

STANDARD PRINT LEGEND: TF CABLE FLEXTREME (SIZE) REMOTE CONTROL & DRILL CORD 600V 07-KA050015-MSHA

JUMPER CABLE 5kV / 15kV

JC 5kV / 15kV Single Conductor Portable Power Cable / Utility Grade


SPECIFICATIONS & STANDARDS

According to ICEA S-97-682, ICEA S-75-381/NEMA WC-58, ASTM B172, ASTM B 33, UL 1072

CONSTRUCTION:
Conductors:
Separator:
Insulation:
Jacket:

Flexible strand tin coated copper, ASTM B-172 and ICEA S-75-381
Synthetic semi-conducting tape separator between the conductor and insulation
Ethylene-propylene rubber (EPR), UL 1072
Red heavy duty CPE thermoset compound, ICEA S-75-381 sec 3.22

FEATURES

APPLICATION

- Suitable as a flexible power lead for temporary connections


- Other industrial applications

Excellent flexibility
Water resistant
Rated and flexible at 40C to +90C
Ozone sunlight oil, grease, weather, chemical resistant

Part
Number

Power Conductor
Size

Conductor
Stranding

AWG / MCM
JC2
JC1/0
JC2/0
JC4/0
JC350
JC500

2
1/0
2/0
4/0
350
500

259x0.0159
414x0.0159
522x0.0159
829x0.0159
1361x0.0159
1921x0.0159

Nominal Insulation
Thickness

Nominal Jacket
Thickness

Nominal
O.D.

Approx.
Weight

inches

inches

inches

mm

Ibs/1000 ft

kgs/km

Ohm/1000 ft

0.175
0.175
0.175
0.175
0.175
0.175

0.080
0.080
0.080
0.080
0.080
0.080

0.820
0.905
0.997
1.140
1.305
1.410

20.8
23.0
25.3
29.0
33.1
35.8

480
639
747
1051
1584
2082

714
951
1112
1564
2357
3099

195
255
293
389
543
678

0.2122 + j0.025
0.1332 + j0.022
0.1059 + j0.022
0.0662 + j0.019
0.0405 + j0.016
0.0284 + j0.014

(1) Ampacity and Impedance Free air measured; Based on continuous duty at 90C conductor temperature

STANDARD PRINT LEGEND:


32

www.tfcable.com

TF CABLE (SIZE) 5/15kV JUMPER CABLE


phone: 630-406-9000

Issue 7.0, July 2015

Ampacity (1) 40C


Ambient Temp.

Impedance (1)

600V GROUNDING CABLE

Single Flexible Copper Conductor Special Transparent PVCJacket


Utility Grade
SPECIFICATIONS & STANDARDS
IEC 61138

CONSTRUCTION:
Conductors:
Jacket:

Flexible stranded bare coopper ASTM B-172 class K


Special transparent PVC compound type ST11 according to IEC 61138 table 7

FEATURES

APPLICATION

- T
 ransparent jacket provides easy confirmation of continuity and ease
of troubleshooting. Extremely flexible stranding for ease of bending
and installation

- A
 transparent PVC jacketed flexible cable used for grounding jumpers installed
temporarily for protective grounding of de-energized circuits

Part Number

Power Conductor
Size

Power Conductor
Stranding

AWG

No. and Diameter


of Stranding

inches

mm

inches

mm

lbs/1000 ft

1323 / 0.010
2107 / 0.010

0.110
0.110

2.79
2.79

0.710
0.850

18.03
21.59

530
799

GRD-CLR2/0-1
GRD-CLR4/0-1

2/0 AWG
4/0 AWG

Nominal Insulation
Thickness

Nominal
O.D.

Approx.
Weight
kgs/km
790
1190

STANDARD PRINT LEGEND:

TF CABLE (SIZE) 600V GROUNDING CABLE

600V GROUNDING CABLE

Single Flexible Copper Conductor Synthetic CPE Compound


Utility Grade
SPECIFICATIONS & STANDARDS

ASTM F855 TYPE I, ASTM B-172, UL 1581

CONSTRUCTION:

Conductors:
Plain annealed copper stranded wires ASTM B-172 class K
Separator:
Polyester tape over conductor
Jacket:
Flame retardant, oil resistant, synthetic thermosetting CPE compound UL 1581 table 50.23
Color of Jacket: Yellow
Maximum Bending Radius: 6xD; D-overall diameter of cable
FEATURES

APPLICATION

- CPE jacket is flame retardant and oil resistant, providing added cable
protection. Extremely flexible stranding for ease of bending and
installation.

- A grounding flexible cable used for grounding jumpers installed temporarily


for protective grounding of de-energized circuits.

Nominal Cross-sectional
Area of Conductor

Number of Wires in
Conductor

Nominal Thickness
of Jacket

Approximate Overall
Diameter

Approximate Weight

AWG

No. & diam. of strands

inches

inches

lbs/1000ft

GRDCPE-YEL2/0-1
GRDCPE-YEL4/0-1

1323 / 0.010
2107 / 0.010

0.106
0.110

0.685
0.839

558
813

STANDARD PRINT LEGEND:

TF CABLE (size) 600V GROUNDING CABLE mfg. acc to ASTM F855 type I

Issue 7.0, July 2015

phone: 630-406-9000

www.tfcable.com

33

TF SAP INDEX
TYPE W 1/C 2000V RHH/RHW-2 - PAGE 1
TF SAP INDEX

TF CABLE P/N

TF SAP INDEX

W8-1X

G-012327

W3/0-5

G-012423

W6-1X

G-012328

W4/0-5

G-012424

W4-1X

G-012330

W6-6

G-012425

W2-1X

G-012331

W1-1X

G-012333

W1/0-1X

G-012336

W2/0-1X

G-012337

W3/0-1X

G-012342

W4/0-1X

G-012347

W250-1X

G-012350

W350-1X

G-012352

W500-1X

G-012354

TYPE W 2/C 2000V - PAGE 2

TYPE G-GC 2000V INDUSTRIAL - PAGE 6


TF CABLE P/N

TF SAP INDEX

GGC8-3

G-004999

GGC6-3

G-005002

GGC4-3

G-005006

GGC2-3

G-005012

GGC1-3

G-005018

GGC1/0-3

G-005021

GGC2/0-3

G-005028

GGC3/0-3

G-005032

GGC4/0-3

G-005038

TF CABLE P/N

TF SAP INDEX

W8-2

G-012356

GGC250-3

G-005041

W6-2

G-012357

GGC350-3

G-005044

W4-2

G-012358

GGC500-3

G-005049

W2-2

G-012359

TYPE W 3/C 2000V - PAGE 3

TYPE G 2000V INDUSTRIAL - PAGE 7


TF CABLE P/N

TF SAP INDEX

TF CABLE P/N

TF SAP INDEX

G8-4

G-004979

W8-3

G-012363

G6-4

G-024691

W6-3

G-012365

G4-4

G-004983

W4-3

G-012366

G2-4

G-004984

W2-3

G-012367

W1-3

G-012368

G1-4

G-004986

W1/0-3

G-012369

G1/0-4

G-004987

W2/0-3

G-012370

G2/0-4

G-004989

W3/0-3

G-012371

G3/0-4

G-004990

W4/0-3

G-012372

G4/0-4

G-004991

W250-3

G-012373

G250-4

G-004992

W350-3

G-012374

G350-4

G-004993

W500-3

G-012375

G500-4

G-004995

TYPE W 4/C 2000V - PAGE 4


TF CABLE P/N

TF SAP INDEX

W8-4

G-012377

W6-4

G-012378

W4-4

G-012383

W2-4

G-012391

TYPE DLO/RRH/RHW-2/RW90 2000V - PAGE 8 & 9


TF CABLE P/N

TF SAP INDEX

DLO14

G-011508

DLO12

G-011516

DLO10

G-011517

DLO8

G-011519

DLO6

G-011521

W1-4

G-012396

W1/0-4

G-012397

DLO4

G-011523

W2/0-4

G-012399

DLO2

G-011525

W3/0-4

G-012405

DLO1

G-011526

W4/0-4

G-012407

DLO1/0

G-011527

W250-4

G-012410

W350-4

G-012412

DLO2/0

G-011529

W500-4

G-012414

DLO3/0

G-011530

DLO4/0

G-011532

DLO262

G-011534

TYPE W 5/C & 6/C 2000V - PAGE 5

34

TYPE W 5/C & 6/C 2000V - CONTINUED

TF CABLE P/N

TF CABLE P/N

TF SAP INDEX

DLO313

G-011536

W8-5

G-012415

DLO373

G-011538

W6-5

G-012416

DLO444

G-011542

W4-5

G-012418

DLO535

G-011545

W2-5

G-012419

DLO646

G-011548

W1-5

G-012420

DLO777

G-011549

W1/0-5

G-012421

DLO929

G-011550

W2/0-5

G-012422

DLO1111

G-011551

www.tfcable.com

phone: 630-406-9000

Issue 7.0, July 2015

TF SAP INDEX
TYPE SHD-GC 5000V - CONTINUED

TYPE W 2000V CSA MINING - PAGE 10


TF CABLE P/N

TF SAP INDEX

TF CABLE P/N

TF SAP INDEX

W2/0-4MNG-CSA

G-012402

SHDGC5KV2/0-3

G-005095

W4/0-4MNG-CSA

G-012408

SHDGC5KV4/0-3

G-005098

SHDGC5KV350-3

G-005100

SHDGC5KV500-3

G-005102

TYPE G-GC 2000V MINING - PAGE 11


TF CABLE P/N

TF SAP INDEX

GGC2-3MNG

G-005014

GGC1-3MNG

G-005016

TF CABLE P/N

TF SAP INDEX

GGC1/0-3MNG

G-005024

SHDGC5KV2-3CSA

G-005088

GGC2/0-3MNG

G-005026

SHDGC5KV1/0-3CSA

G-005093

GGC4/0-3MNG

G-005036

SHDGC5KV2/0-3CSA

G-005096

GGC350-3MNG

G-005046

TYPE G-GC 2000V CSA MINING - PAGE 12

TYPE SHD-GC 5000V CSA - PAGE 18

TYPE SHD-GC 8000V/15000V - PAGE 19


TF CABLE P/N

TF SAP INDEX

TF CABLE P/N

TF SAP INDEX

SHDGC8KV1/0-3

G-005115

GGC8-3MNG-CSA

G-005000

SHDGC8KV2/0-3

G-005118

GGC6-3MNG-CSA

G-005005

SHDGC8KV4/0-3

G-005129

GGC4-3MNG-CSA

G-005010

SHDGC15KV2-3

G-005138

GGC2-3MNG-CSA

G-005013

SHDGC15KV1/0-3

G-005139

GGC1-3MNG-CSA

G-005020

GGC1/0-3MNG-CSA

G-005022

SHDGC15KV2/0-3

G-005140

GGC2/0-3MNG-CSA

G-005030

SHDGC15KV4/0-3

G-005142

GGC3/0-3MNG-CSA

G-005035

GGC4/0-3MNG-CSA

G-005039

TYPE MP-GC 5000V/15000V XLP/PVC - PAGE 13


TF CABLE P/N

TF SAP INDEX

MPGC5KV2/0-3

G-018394

MPGC5KV4/0-3

G-018395

MPGC5KV2/0-3-RED

G-020116

MPGC15KV2/0-3

G-018401

MPGC15KV4/0-3

G-018404

TYPE MP-GC 8000V/15000V ERP/CPE - PAGE 14


TF CABLE P/N

TF SAP INDEX

MPGC8KV2/0-3-CPE

G-004618

MPGC15KV2-3-CPE

G-004624

MPGC15KV4/0-3-CPE

G-004622

TYPE SHD-GC 2000V - PAGE 15

TYPE SHD-GC 8000V/15000V CSA - PAGE 20


TF CABLE P/N

TF SAP INDEX

SHDGC8KV1-3CSA

G-005111

SHDGC8KV1/0-3CSA

G-005114

SHDGC8KV2/0-3CSA

G-005117

SHDGC15KV4/0-3CSA

G-005143

TYPE SJOOW 300V - PAGE 21


TF CABLE P/N

TF SAP INDEX

SJOOW18-2 IF

G-020710

SJOOW18-3 IF

G-020913

SJOOW18-4 IF

G-021009

SJOOW16-2 IF

G-012668

SJOOW16-3 IF

G-012672

SJOOW16-4 IF

G-012678

SJOOW14-2 IF

G-012669

SJOOW14-3 IF

G-012673

TF CABLE P/N

TF SAP INDEX

SJOOW14-4 IF

G-012679

SHDGC2KV6-3

G-005052

SJOOW12-2 IF

G-012670

SHDGC2KV4-3

G-005056

SJOOW12-3 IF

G-012674

SHDGC2KV2-3

G-005060

SHDGC2KV1/0-3

G-005067

SJOOW12-4 IF

G-012680

SHDGC2KV2/0-3

G-005071

SJOOW10-2 IF

G-012671

SHDGC2KV4/0-3

G-005077

SJOOW10-3 IF

G-012675

SJOOW10-4 IF

G-012681

TYPE SHD-GC 2000V CSA - PAGE 16


TF CABLE P/N

TF SAP INDEX

SHDGC2KV6-3CSA

G-005053

SHDGC2KV2-3CSA

G-005059

SHDGC2KV1-3CSA

G-005066

SHDGC2KV1/0-3CSA

G-005069

SHDGC2KV2/0-3CSA

G-005075

SHDGC2KV4/0-3CSA

G-005078

TYPE SHD-GC 5000V - PAGE 17

TYPE SOOW 600V PORTABLE CORD - PAGE 22


TF CABLE P/N

TF SAP INDEX

SOOW18-2 IF

G-021660

SOOW18-3 IF

G-012632

SOOW18-4 IF

G-021117

SOOW16-2 IF

G-012628

SOOW16-3 IF

G-012633

SOOW16-4 IF

G-012639

SOOW14-2 IF

G-012629

SOOW14-3 IF

G-012635

SOOW14-4 IF

G-012640

TF CABLE P/N

TF SAP INDEX

SHDGC5KV4-3

G-005086

SHDGC5KV2-3

G-005087

SOOW12-2 IF

G-012630

SHDGC5KV1-3

G-005091

SOOW12-3 IF

G-012636

SHDGC5KV1/0-3

G-005092

SOOW12-4 IF

G-012641

Issue 7.0, July 2015

phone: 630-406-9000

www.tfcable.com

35

TF SAP INDEX
TYPE SOOW 600V PORTABLE CORD - CONTINUED
TF SAP INDEX

TF CABLE P/N

TF SAP INDEX

SOOW10-2 IF

G-012631

SOOW16-20

G-012320

SOOW10-3 IF

G-012637

SOOW16-24

G-021025

SOOW10-4 IF

G-012642

SOOW16-30

G-012323

SOOW16-37

G-012324

SOOW16-40

G-021681

SOOW16-52

G-021682

SOOW16-60

G-021683

SOOW14-5

G-012297

SOOW14-6

G-012303

SOOW14-7

G-012305

SOOW14-8

G-012310

SOOW14-10

G-018949

SOOW14-12

G-012314

SOOW14-16

G-012318

SOOW14-20

G-020946

SOOW14-24

G-021684

SOOW14-30

G-019879

SOOW14-37

G-012325

SOOW12-5

G-021685

SOOW12-6

G-020905
G-012307

TYPE SOOW 600V UL/CSA POWER CABLE - PAGE 23


TF CABLE P/N

TF SAP INDEX

SOOW8-3 IF-UL/CSA

G-021339

SOOW8-4 IF-UL/CSA

G-012643

SOOW8-5 IF-UL/CSA

G-020911

SOOW6-3 IF-UL/CSA

G-019893

SOOW6-4 IF-UL/CSA

G-012644

SOOW6-5 IF-UL/CSA

G-012646

SOOW4-3 IF-UL/CSA

G-012638

SOOW4-4 IF-UL/CSA

G-021662

SOOW4-5 IF-UL/CSA

G-021663

SOOW2-3 IF-UL/CSA

G-021666

SOOW2-4 IF-UL/CSA

G-021667

SOOW2-5 IF-UL/CSA

G-021668

TYPE SOOW 600V MSHA POWER CABLE - PAGE 24


TF CABLE P/N

TF SAP INDEX

SOOW8-2 IF

G-012661

SOOW12-7

SOOW8-3 IF

G-012663

SOOW12-8

G-012311

SOOW8-4 IF

G-012664

SOOW12-9

G-019864

SOOW8-5 IF

G-012666

SOOW12-10

G-020728

SOOW6-2 IF

G-021912

SOOW12-12

G-012315

SOOW6-3 IF

G-021566

SOOW12-14

G-021686

SOOW6-4 IF

G-012665

SOOW12-16

G-012319

SOOW6-5 IF

G-012667

SOOW12-20

G-012321

SOOW4-2

G-022773

SOOW12-24

G-020901

SOOW4-3

G-012281

SOOW12-26

G-019839

SOOW4-4

G-012294

SOOW12-30

G-018952

SOOW4-5

G-012300

SOOW12-37

G-012326

SOOW2-2

G-021916

SOOW12-44

G-021687

SOOW2-3

G-012282

SOOW10-5

G-021688

SOOW2-4

G-012295

SOOW10-6

G-020104

SOOW2-5

G-012301

SOOW10-7

G-012308

SOOW10-8

G-012312

SOOW10-10

G-019809

SOOW10-12

G-021691

SOOW10-16

G-019834

SOOW10-20

G-012322

SOOW10-26

G-021692

SOOW10-30

G-021694

SOOW10-40

G-021696

TYPE SOOW 600V CONTROL CABLE - PAGE 25 & 26

36

TYPE SOOW 600V CONTROL CABLE - CONTINUED

TF CABLE P/N

TF CABLE P/N

TF SAP INDEX

SOOW18-5

G-021669

SOOW18-6

G-020706

SOOW18-7

G-021670

SOOW18-8

G-021672

SOOW18-10

G-021676

SOOW18-12

G-012313

SOOW18-14

G-012316

SOOW18-16

G-019887

TF CABLE P/N

TF SAP INDEX

SOOW18-20

G-020708

SOOW18-24

G-021677

SOOW18-3 IF-105C-YEL

G-012651

SOOW18-30

G-021679

SOOW18-4 IF-105C-YEL

G-012656

SOOW16-5

G-012296

SOOW16-3 IF-105C-YEL

G-012652

SOOW16-6

G-020709

SOOW16-4 IF-105C-YEL

G-012657

SOOW16-7

G-012304

SOOW14-3 IF-105C-YEL

G-012653

SOOW16-8

G-020909

SOOW16-9

G-021680

SOOW14-4 IF-105C-YEL

G-012658

SOOW16-10

G-020908

SOOW12-3 IF-105C-YEL

G-012654

SOOW16-12

G-021338

SOOW12-4 IF-105C-YEL

G-012659

SOOW16-14

G-020727

SOOW10-3 IF-105C-YEL

G-012655

SOOW16-16

G-012317

SOOW10-4 IF-105C-YEL

G-012660

www.tfcable.com

phone: 630-406-9000

TYPE SOOW 600V 105C YELLOW - PAGE 27

Issue 7.0, July 2015

TF SAP INDEX
TYPE ARC-WELDING CABLE 600V - CONTINUED

TYPE SOOW/H07RN-F - PAGE 28

TF CABLE P/N

TF SAP INDEX

WC4-RED

G-012896

WC2-RED

G-012899

WC1-RED

G-012906

WC1/0-RED

G-012912

WC2/0-RED

G-012920

WC3/0-RED

G-012929

WC4/0-RED

G-012934

TF CABLE P/N

TF SAP INDEX

SOOW/H07RN-F18-3

G-012544

SOOW/H07RN-F18-4

G-012550

SOOW/H07RN-F16-3

G-012546

SOOW/H07RN-F16-4

G-012552

SOOW/H07RN-F14-3

G-012547

SOOW/H07RN-F14-4

G-012553

SOOW/H07RN-F12-3

G-020045

SOOW/H07RN-F12-4

G-012554

SOOW/H07RN-F10-3

G-012548

TF CABLE P/N

TF SAP INDEX

SOOW/H07RN-F10-4

G-012555

SOOW/H07RN-F8-3

G-012549

DC10-5

G-012528

SOOW/H07RN-F8-3

G-012556

TYPE SC - STAGE LIGHTING CABLE 600V - PAGE 29


TF CABLE P/N

TF SAP INDEX

STAGE6

G-012512

STAGE4

G-012513

STAGE2

G-012514

STAGE1

G-012515

STAGE1/0

G-021032

STAGE2/0

G-012516

STAGE3/0

G-021508

STAGE4/0

G-012517

STAGE6-GRN

G-012511

TYPE RHH/RHW-2/USE-2 600V - PAGE 30


TF CABLE P/N

TF SAP INDEX

USE2-14

G-005799

USE2-12

G-005800

USE2-10

G-005801

USE2-8

G-005803

USE2-6

G-005805

UDE2-4

G-005809

USE2-2

G-005811

USE2-1/0

G-005812

USE2-2/0

G-005814

USE2-4/0

G-005816

USE2-250

G-005818

USE2-350

G-005819

USE2-500

G-005820

USE2-750

G-005821

USE2-1000

G-005822

USE2-8-GRN

G-005804

USE2-6-WHT

G-005806

USE2-6-RED

G-005807

TYPE DRILL CORD 600V - PAGE 32

JUMPER CABLE 5000V/15000V - PAGE 32


TF CABLE P/N

TF SAP INDEX

JC2

G-012682

JC1/0

G-012683

JC2/0

G-012684

JC4/0

G-012685

JC350

G-021686

JC500

G-012687

GROUNDING CABLE PVC 600V - PAGE 33


TF CABLE P/N

TF SAP INDEX

GRD-CLR2/0-1

G-008654

GRD-CLR4/0-1

G-008655

GROUNDING CABLE CPE 600V - PAGE 33


TF CABLE P/N

TF SAP INDEX

GRDCPE-YEL2/0-1

G-023987

GRDCPE-YEL4/0-1

G-023988

MSHA

TYPE ARC-WELDING CABLE 600V - PAGE 31


TF CABLE P/N

TF SAP INDEX

WC6

G-012890

WC4

G-012894

WC2

G-012904

WC1

G-012910

WC1/0

G-012917

WC2/0

G-012927

WC3/0

G-012931

WC4/0

G-012933

WC250

G-012941

WC350

G-012943

WC500

G-012945

WC6-RED

G-012886

Issue 7.0, July 2015

phone: 630-406-9000

www.tfcable.com

37

Terms & Conditions


1. Quotations

a) Quotations on products from inventory are for immediate acceptance and price is subject to product availability and copper fluctuations.

b) Quotations for specially manufactured products are valid for 30 days.
2. Lead Times

a) Manufacturing lead times are stated at time of quotation and are a best estimate based on current conditions. Lead times may change due to factory capacity at time of order placement.

b) All inventory items are for immediate availability and products are subject to prior sale.
3. Minimum Order - $500
4. Order Acceptance

a) No Purchase Order shall be binding unless and until officially accepted in writing by TF. Any terms and conditions of Purchase Order which are in addition to or inconsistent with TF
terms and conditions shall not be binding and shall not apply to the transaction, unless specifically agreed to in writing by TF.

b) Large orders that meet minimum contract guidelines have the option to firm the value of metal content to the LME next business day price.
5. Product Backorders

a) Product backorders are accepted at original order price providing the confirmed availability is within 4 weeks of order placement

b) Backorders beyond the known availability will be subject to current price in effect at time of shipment.
6. Copper Pricing Adjustments

a) Unless otherwise negotiated, manufactured orders shipping from TF Factories are subject to metal escalation or de-escalation at time of shipment. Adjusted metals are based on the
published London Metal Exchange (LME) previous months average from date of shipment.

b) Warehouse orders are adjusted to the current market price level at time of order.
7. Other Raw Materials Adjustments

Prices are subject to other raw material increases and pricing may be revised after expiration of the quote acceptance period.
8. Quantity Variations

Total quantities and individual reel lengths on manufactured items may vary from original ordered amount. Variations are intended to be reasonable and tolerances on product types are

stated on the quotations and orders.

a) Shipments from TF Kable Factories are set at a quantity tolerance of +/- 10%

b) Shipments from TF warehouse are set at a quantity tolerance of -0% to +3%.
9. Shipping and Delivery Schedule

Projected shipping and delivery schedule is a best estimate based on current conditions. TF assumes no liability for loss, damage or consequential damages due to delays.
10. Payment Terms

a) Factory direct shipments are net 75 days from date of invoice

b) Warehouse shipments are net 30 days from date of invoice
11. Cancellation

a) Orders are considered non-cancelable.

b) Exceptions are at the discretion of TF. Manufactured orders will be subject to cancellation charges and commiserate to the resources committed for order fulfillment. Any order, once
accepted by TF shall not be subject to cancellation except on terms that protect TF against loss. If the order is cancelled for any reason, TF shall not be liable for incidental or
consequential damages.
12. Returns Standard Inventory Product

a) Applications for returning material are to me made within 30 days of receipt

b) Customer specified cut lengths are non-returnable

c) No returns will be accepted without a return authorization

d) Credit will be provided only after receipt and verification that the product is still in the original packaging received in a non-damaged saleable condition.

e) Restocking charges will apply and will be set at the time of RMA request.
13. Returns Factory Direct Shipments and Specially Manufactured Products

Factory direct shipments and specially manufactured products are non-returnable
14. Freight Policy Warehouse Shipments

a) TF will use the best, least expensive surface transportation. Reasonable care is exercised in packing products for shipment, and TF assumes no responsibility for delay, breakage or
damage after having made delivery in good order to the carrier.

b) Freight costs are calculated on point-to-point delivery by enclosed common carrier van to a standard truck-height loading dock
15. Freight Methods Warehouse Shipments

a) Prepaid and Allowed - FOB Destination, Best Way TF selected carrier.

b) Prepaid and Charge - FOB Shipping Point, Best Way by customer-selected carrier from list of TF approved carriers.

c) Freight Collect FOB Shipping Point, Best Way by customer selected carrier. Customer provides TF with accurate freight-collect account numbers.
16. Special Freight Conditions

a) Expedited Shipping including Guaranteed Delivery TF must specifically accept in writing on confirming order and shipment is made by TF selected carrier. Customer is responsible
for all additional costs.

b) Accessorial service charges will apply upon special shipping requests or additional costs incurred when making delivery including but not limited to Lift Gate Service, Redelivery,
Waiting Time, Storage, Re-consignment, Diversion, Transloading, Residential Delivery, Saturday delivery.

c) Special restrictive conditions regarding loading or unloading, weight and equipment limitations will be communicated to TF at time of order.
17. Inspection for Damage and Shortages

a) All shipments from TF should be inspected for possible freight damage or shortage prior to acceptance.

b) Damaged or shortage should be specifically noted on bill of lading and packing slip at time of delivery.

c) Applications for invoice adjustment due to damage or shortages are required to be submitted no later than 30 days from receipt.

d) Damage or shortage claims must be accompanied by the drivers copy of the delivery receipt noting the specific items claimed.

e) Unless specifically authorized otherwise, claims are not to be deducted from the original invoice but will be processed on a separate credit memo.
18. Reel Length Policy and Specially Requested Cut Lengths From Inventory

a) No order will be accepted that requires a master length of cable to be cut resulting in a remaining unsellable short length.

b) Orders requesting specific cut lengths will be subject to cutting charges.
19. Reels

a) Cables are supplied on non-returnable wooden reels for domestic use within North America. Reel size and reel capacity will be determined by TF

b) Reels, Palletized Boxes and Coils will have a weather protecting wrap
Additional costs for customer specified packaging include but not limited to; IPPC reels and pallets, lagging and palletize reel cradling
20. Confidentiality of Technical Data and Content of Catalog Sheets

a) If any written technical information, detailed specifications, drawings or other technical data are submitted to the customer in connection with a quotation or order, other than published
data, such data will be furnished in confidence to permit the evaluation of TFs conformance with the order requirements.

b) Catalog sheets are considered accurate but may have typographical errors or inadvertent omissions of information. TF is not responsible for errors of this nature.

c) Information contained in catalog sheets is subject to change without notice.

38

www.tfcable.com

phone: 630-406-9000

Issue 7.0, July 2015

Product Warranty
Tele-Fonika Cable Americas, a wholly owned subsidiary of Tele-Fonika Kable, warrants that the cable will:

Be free from defects in material and workmanship

Conform fully to published Tele-Fonika specifications, or to the specifications as otherwise agreed and confirmed by Tele-Fonika in writing

Meet all applicable independent governing standards required for the listing and for the intended application
Warranty Duration
Warranty period is 12 months from date of installation not to exceed 18 months from date of Tele-Fonika invoice.
Warranty Conditions

Liability covers only defects inherent in the product.

Product installation and claim must have been completed prior to the expiration of the warranty period.

User must resolve all non-related causes prior to claim.

User must provide verification that products received proper transporting, storing, placing and installation in accordance with generally accepted methods provided for in standards, electrical
codes and trade procedures, with respect to the purpose of the product specified by the manufacturer.

Cable repair or replacement will be performed only after TF Kable has reviewed and verified the claim prior to removal, replacement or repair of defective product.

In instances of a groundless warranty claim, customer shall be obliged to pay the costs incurred by TF Kable. A groundless warranty is defined as a situation where the defect does not
exist or the defect has been created by conditions not related to the product.
Claim Procedure

Claim must have accompanying documentation proving product purchase related to the warranty including quantity, packing slip, place and date of purchase.

Warranty claim must be conveyed to the immediate supplier of the product or to TF Kable if supplied directly.

Warranty claim must contain a description of the revealed defect.

If claim is prior to installation, the user must provide a sample of the defective product to TF Kable.

If claim is after installation user shall provide TF Kable free and easy access to the product.

User must properly secure the product or place of installation where the defects are revealed and let TF Kable inspect the product and all receiving and installation documents.

The warranty notice shall be directed at the following address:
TELE-FONIKA CABLE AMERICAS
555 Remington Blvd
Bolingbrook, IL 60440
USA
Warranty Remedy

Upon an accepted warranty claim the company will repair or replace the defective product at its discretion.

Upon an accepted warranty claim the defective product shall be the property of the Warrantor and returned.
Warranty Exclusions

Warranty does not cover non-related products or causes.

Warranty does not cover using a product not in accordance to its designed purpose, features or rules of use.

Warranty does not cover any repairs, adaptation or changes in construction performed by persons other than Warrantor.
Warranty limitations
This warranty is exclusive and in lieu of all other warranties, whether express or implied, or statutory, including, but not by way of limitation, any warranty of merchantability or fitness for any particular
purpose, non-infringement or any other matter. The remedies provided for in the preceding paragraphs shall constitute the sole recourse of end-user against Tele-Fonika Cable for breach of any
obligations to end-user, whether the claim is made in tort or in contract, including claims based on breach of warranty, negligence, strict liability, fraud, misrepresentation, or otherwise. In no event
shall Tele-Fonika Cable be liable for special, indirect, incidental or consequential damages (regardless of the form of action, whether in contract or in tort, including negligence), including, without
limitation, lost profits or economic damage arising out of the failure. Nor shall the liability of Tele-Fonika Cable for any claims or damage arising out of or connected with this warranty or the
manufacture, sale, delivery, installation or use of the products exceed the purchase price of the products and the installation.

www.tfcable.com

39

555 Remington Blvd., Suite A


Bolingbrook, Illinois 60440
(630) 406-9000 phone (630) 406-6574 fax
www.tfcable.com

555 Remington Blvd, Bolingbrook, IL 60440, U.S.A.


phone (630) 406-9000 | fax (630) 406-6574
www.tfcable.com