Perform this procedure Install/Upgrade Array Health Analyzer only if this utility is not yet installed or if
you are upgrading to a later version of AHA.
Note: To check if AHA is installed on this workstation check Windows add/remove programs manager.
.2
Done
Done
Download the latest released version of AHA from the Service Partners Web or Powerlink to the
customers Windows workstation.
.3
Done
.b Run the AHA executable file, which will install the AHA utility into the ConnectEMC directory, e.g.
C:\Program Files\EMC\ConnectEMC\AHA
.c On running the AHA executable, it checks if a specific version of JRE installation exists on the
Windows workstation. If not present, it will install it by executing jre-6u21-windows-i586.exe
automatically. Follow the prompts to complete the JRE installation.
.d Once the JRE installation is complete, AHA application installation starts.
.e Once the AHA installation is complete, the AHA service automatically starts. (Check Services
Manager & Windows Task Manager to confirm).
.f To stop the AHA application, go to services by typing services.msc in Start -> Run. Select the AHA
service & click on Stop. The AHA service will get stopped & AHA_Svc_main.exe will get deleted
from the Windows Task Manager.
.g To start AHA, click Start from services. Click Restart if the service needs to be restarted.