MODIFIED TEST REPORT

EN 60335-2-41
Safety of household and similar electrical appliances

Part 2: particular requirements for pumps for liquids having a temperature not
exceeding 35 C
Report
Reference No.................................... : 3035083
Tested by (+ signature) ..................... : Tony Dorta

Signature on file

Approved by (+ signature) ................ : Lawrence Todd

Signature on file

Date of issue ..................................... : December 4, 2002


Date of revised .................................. : Modification M1: 2016 January 7
Contents ........................................... : 6 pages
Revised by:

Ting Wang

Approved by:
Thomas Cabaj
Testing laboratory
Name ................................................ : Intertek Testing Services NA, Inc.
Address ............................................. : 545 E. Algonquin Rd. Arlington Heights, IL. 60005 (USA)
Testing location................................. : Intertek Testing Services NA, Inc.
.......................................................... : 545 E. Algonquin Rd. Arlington Heights, IL. 60005 (USA)
Client
Name ................................................ : Tsurumi (America), Inc.
Address ............................................. : 1625 Fullerton Court
.......................................................... : Glendale Heights, IL 60139 USA
Test specification
Standard ........................................... : IEC 60335-2-41:2002 (Third edition) + A1:2004 used in conjunction
with IEC 60335-1:2001 (Fourth Edition) modified + A1:2004 and/or
EN 60335-2-41:2003 + A1:2004 used in conjunction with
EN 60335-1:2002 + A1:2004 + A11:2004 and EN 50366:2003
Test procedure ................................. : CCA-scheme
Procedure deviation .......................... : N.A.
Non-standard test method ................ : N.A.
Test Report Form/blank test report
Test Report Form No. ....................... : 6335241C/98-09
Master TRF ....................................... : reference No. A4100B, dated 97-07
Copyright reserved to the bodies participating in the Committee of Certification Bodies (CCB) and/or the
bodies participating in the CENELEC Certification Agreement (CCA).

Tsurumi (America), Inc

page 2 of 6

Report No. 3035083


Modification M1: 2016-01-07

Test item
Description ........................................ : Submersible Pump
Trademark ........................................ : Tsurumi Pump
Model and/or type reference ............. : Various (see page 5 of original report for details)
Manufacturer..................................... : Tsurumi Manufacturing Co., Ltd.
Rating(s) ........................................... : Various (see page 5 original report for details)
.......................................................... :
Particulars: test item vs. Test requirements
Electrical safety class ................................................ : Class I
IP number .................................................................. : IPX8
Switch ........................................................................ : No
Thermostat ................................................................ : No
Thermal cut-out ......................................................... : Yes
Timer.......................................................................... : No
Accessories ............................................................... : No
Supply cord ................................................................ : Yes
.... with attachment type ............................................. : Y
Test case verdicts
Test case does not apply to the test object ............... : N(.A.)
Test item does meet the requirement ........................ : P(ass)
Test item does not meet the requirement .................. : F(ail)
................................................................................... :
Testing
Date of receipt of test item ........................................ : 10/20/2015
Date(s) of performance of test ................................... : 12/23/2015, 1/4/2016

TRF No.: 6335241C

Tsurumi (America), Inc

page 3 of 6

Report No. 3035083


Modification M1: 2016-01-07

General remarks
This report is not valid as a CB Test Report unless appended to a CB Test Certificate issued by a NCB, in
accordance with IECEE 02.
This test report shall not be reproduced except in full without the written approval of the testing laboratory.
The test results presented in this report relate only to the item tested.

Modification M1: 2016-01-07: The report was updated under project G102280107 to add alternate motor
models which have same rating as the existing motors for different pumps. Standards requested not to be
updated.
Added alternate motor HOE-2B and HOE-2D for
HS2.4S-52, 2HSZ2.4S-52 pump
Added alternate motor LUE-1B and LUE-1D for LB480-52 , LB-480A-52 , LBZ-480-52 , LSR2.4S-51 ,
LSC1.4S-51 pump. Thermal protector for these
motor models are 17AM028
Since winding ratings and protector changed, the follow tests were performed.

TEST
Normal Temperature Test
Leakage Current Test

IEC/EN
60335-2-41
11.1
13

COMMENTS
Pass
Pass

TRF No.: 6335241C

Tsurumi (America), Inc

page 4 of 6

Report No. 3035083


Modification M1: 2016-01-07

11.8

TABLE: temperature rise measurements

room temperature t1 (C) ..................................... :

21.086

---

room temperature t2 (C) ..................................... :

21.35

---

test voltage (V) ..................................................... :

122V

---

Winding temperature rise measurements


temperature rise dT of winding:

Motor winding

13.2

R1()

2.343

R2 ()

2.58

dT (K)

25.6

required

Insulation

dT (K)

class

65

TABLE: leakage current measurements at operating temperature

heating appliances: at 1,15 times maximum rated

N/A

---

122 V

---

input (W) .............................................................. :


motor-operated and combined appliances: at
1,06 times rated voltage (V) ................................. :
leakage current I between:

I (mA)

required I (mA)

Neutral open, normal polarity

0.13

0.75

Neutral open, reverse polarity

0.13

0.75

Neutral closed, normal polarity

0.05

0.75

Neutral closed, reverse polarity

0.075

0.75

TRF No.: 6335241C

Tsurumi (America), Inc

page 5 of 6

Report No. 3035083


Modification M1: 2016-01-07

24.1
Component

TABLE: Model HS(Z)2.4S-52 components


Manufacturer

Type/model

Technical Data

Standard

conformity1)

Trademark
Power Cord

Mark(s) of

H07 RN-F

See attached

IEC 60245-4

CE, VDE

IEC 60332-1
IEC 60228
Attachment Plug

Will be
provided by
distributor

Motor Assembly

Leadership

HSE-2B or

See attached

IEC 60034-1

(Staring Capacitor,

HSE-2D or

IEC 600252

Internal wiring and

HOE-2B or

IEC 60034-11

thermal protector)

HOE-2D

Strain Relief

Tsurumi

CE

CE

) an asterisk indicates a mark which assures the agreed level of surveillance

24.1
Component

TABLE: Model LB(Z)-480-52 and LB-480A-52 components


Manufacturer

Type/model

Technical Data

Standard

conformity1)

Trademark
Power Cord

Mark(s) of

H07 RN-F

See attached

IEC 60245-4

CE, VDE

IEC 60332-1
IEC 60228
Attachment Plug

Will be
provided by
distributor

Motor Assembly

Leadership

LSE-1B or

See attached

IEC 60034-1

(Staring Capacitor,

LSE-1D or

IEC 600252

Internal wiring and

LUE-1B or

IEC 60034-11

thermal protector)

LUE-1D

Strain Relief

Tsurumi

CE

CE

Water Level Probbe Shinwa

EL-2P-100 or

100-120 or 200-

(for Model LB-

Kogyo

EL-2P-200

240Vac, 7A

480A-52) alternate

Co.,Ltd

) an asterisk indicates a mark which assures the agreed level of surveillance

TRF No.: 6335241C

Tsurumi (America), Inc

page 6 of 6

Report No. 3035083


Modification M1: 2016-01-07

24.1
Component

TABLE: Model LSR2.4S-51 components


Manufacturer

Type/model

Technical Data

Standard

conformity1)

Trademark
Power Cord

Mark(s) of

H07 RN-F

See attached

IEC 60245-4

CE, VDE

IEC 60332-1
IEC 60228
Attachment Plug

Will be
provided by
distributor

Motor Assembly

Leadership

LSE-1B or

See attached

IEC 60034-1

(Staring Capacitor,

LSE-1D or

IEC 600252

Internal wiring and

LUE-1B or

IEC 60034-11

thermal protector)

LUE-1D

Strain Relief

Tsurumi

CE

CE

) an asterisk indicates a mark which assures the agreed level of surveillance

24.1
Component

TABLE: Model LSC1.4S-51 components


Manufacturer

Type/model

Technical Data

Standard

conformity1)

Trademark
Power Cord

Mark(s) of

H07 RN-F

See attached

IEC 60245-4

CE, VDE

IEC 60332-1
IEC 60228
Attachment Plug

Will be
provided by
distributor

Motor Assembly

Leadership

LSE-1B or

See attached

IEC 60034-1

(Staring Capacitor,

LSE-1D or

IEC 600252

Internal wiring and

LUE-1B or

IEC 60034-11

thermal protector)

LUE-1D

Strain Relief

Tsurumi

CE

CE

) an asterisk indicates a mark which assures the agreed level of surveillance

TRF No.: 6335241C

AMENDED TEST REPORT


EN 60335-2-41
Safety of household and similar electrical appliances
Part 2: particular requirements for pumps for liquids having a temperature not
exceeding 35 C
Report
Reference No.................................... : 3035083
Tested by (+ signature) ..................... : Tony Dorta

Signature on file

Approved by (+ signature) ................ : Lawrence Todd

Signature on file

Date of issue ..................................... : December 4, 2002


Date of revised .................................. : Amendment A1: February 18, 2015
Contents ........................................... : 2 pages
Revised by:
Riccardo Bellina
Approved by:

Thomas Cabaj

Testing laboratory
Name ................................................ : Intertek Testing Services NA, Inc.
Address ............................................. : 545 E. Algonquin Rd. Arlington Heights, IL. 60005 (USA)
Testing location................................. : Intertek Testing Services
rd

.......................................................... : 2595 S.W. 153 Drive, Beaverton, OR 97006


Client
Name ................................................ : Tsurumi (America), Inc.
Address ............................................. : 1625 Fullerton Court
.......................................................... : Glendale Heights, IL 60139 USA
Test specification
Standard ........................................... : IEC 60335-2-41:2002 (Third edition) + A1:2004 used in conjunction
with IEC 60335-1:2001 (Fourth Edition) modified + A1:2004 and/or
EN 60335-2-41:2003 + A1:2004 used in conjunction with
EN 60335-1:2002 + A1:2004 + A11:2004 and EN 50366:2003
Test procedure ................................. : CCA-scheme
Procedure deviation .......................... : N.A.
Non-standard test method ................ : N.A.
Test Report Form/blank test report
Test Report Form No. ....................... : 6335241C/98-09
Master TRF ....................................... : reference No. A4100B, dated 97-07
Copyright reserved to the bodies participating in the Committee of Certification Bodies (CCB) and/or the
bodies participating in the CENELEC Certification Agreement (CCA).

TRF No.: 6335241C

Tsurumi (America), Inc

page 2 of 2

Report No. 3035083


Amendment A1: 2015-02-18

Test item
Description ........................................ : Submersible Pump
Trademark ........................................ : Tsurumi Pump
Model and/or type reference ............. : Various (see page 5 of original report for details)
Manufacturer..................................... : Tsurumi Manufacturing Co., Ltd.
Rating(s) ........................................... : Various (see page 5 original report for details)
.......................................................... :
Particulars: test item vs. Test requirements
Electrical safety class ................................................ : Class I
IP number .................................................................. : IPX8
Switch ........................................................................ : No
Thermostat ................................................................ : No
Thermal cut-out ......................................................... : Yes
Timer.......................................................................... : No
Accessories ............................................................... : No
Supply cord ................................................................ : Yes
.... with attachment type ............................................. : Y
General remarks
This report is not valid as a CB Test Report unless appended to a CB Test Certificate issued by a NCB, in
accordance with IECEE 02.
This test report shall not be reproduced except in full without the written approval of the testing laboratory.
The test results presented in this report relate only to the item tested.

Amendment A1: 2015-02-18: The report was updated under project G101918095 to add Tsurumi Pump
as a trademark. Standards were not updated to the latest editions as per clients request. See email in
project folder sent from Michael Klimes Applications Engineer at Tsurumi (America), INC., on 2015-02-06.

TRF No.: 6335241C

TEST REPORT
EN 60335-2-41
Safety of household and similar electrical appliances
Part 2: particular requirements for pumps for liquids having a temperature not
exceeding 35 C
Report
Reference No.................................... : 3035083
Tested by (+ signature) ..................... : Tony Dorta

Signature on file

Approved by (+ signature) ................ : Lawrence Todd

Signature on file

Date of issue ..................................... : December 4, 2002


Date of revised .................................. : August 23,2011
Contents ........................................... : 71 pages
Revised by:
Son La
Approved by:

Wade Shore

Testing laboratory
Name ................................................ : Intertek Testing Services
rd

Address ............................................. : 2595 S.W. 153 Drive, Beaverton, OR 97006


Testing location................................. : as above
.......................................................... :
Client
Name ................................................ : Tsurumi (America), Inc.
Address ............................................. : 1625 Fullerton Court
.......................................................... : Glendale Heights, IL 60139 USA
Test specification
Standard ........................................... : IEC 60335-2-41:2002 (Third edition) + A1:2004 used in conjunction
with IEC 60335-1:2001 (Fourth Edition) modified + A1:2004 and/or
EN 60335-2-41:2003 + A1:2004 used in conjunction with
EN 60335-1:2002 + A1:2004 + A11:2004 and EN 50366:2003
Test procedure ................................. : CCA-scheme
Procedure deviation .......................... : N.A.
Non-standard test method ................ : N.A.
Test Report Form/blank test report
Test Report Form No. ....................... : 6335241C/98-09
Master TRF ....................................... : reference No. A4100B, dated 97-07
Copyright reserved to the bodies participating in the Committee of Certification Bodies (CCB) and/or the
bodies participating in the CENELEC Certification Agreement (CCA).

Tsurumi (America), Inc.

page 2 of 71

Report No. 3035083

Test item
Description ........................................ : Submersible Pump
Trademark ........................................ :
Model and/or type reference ............. : Various (see page XXX for details)
Manufacturer..................................... : Tsurumi Manufacturing Co., Ltd.
Rating(s) ........................................... : Various (see page XXX for details)
.......................................................... :
Particulars: test item vs. test requirements
Electrical safety class ................................................ : Class I
IP number .................................................................. : IPX8
Switch ........................................................................ : No
Thermostat ................................................................ : No
Thermal cut-out ......................................................... : Yes
Timer.......................................................................... : No
Accessories ............................................................... : No
Supply cord ................................................................ : Yes
.... with attachment type ............................................. : Y
Test case verdicts
Test case does not apply to the test object ............... : N(.A.)
Test item does meet the requirement ........................ : P(ass)
Test item does not meet the requirement .................. : F(ail)
................................................................................... :
Testing
Date of receipt of test item ........................................ :
Date(s) of performance of test ................................... :
................................................................................... :

TRF No.: 6335241C

Tsurumi (America), Inc.

page 3 of 71

Report No. 3035083

General remarks
"This report is not valid as a CB Test Report unless appended to a CB Test Certificate issued by a NCB, in

accordance with IECEE 02".


This test report shall not be reproduced except in full without the written approval of the testing laboratory.
The test results presented in this report relate only to the item tested.
"(see remark #)" refers to a remark appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a comma is used as the decimal separator.

This report is the same as 2000842X which was generated for models HS2.4S-61, LB2-400, LB3-750,
LSC, and LSR. The new models added are identical to the previous ones except that the are rated
only for 50Hz while the previous ones were rated for both 50/60Hz. See below for correlation of the

models:
LB2-400 is now LB-480-52
LSC is now LSC 1.4.S-51
LSR is now LSR2.4S-51
This model correlation was provided by Dan Tyler at Tsurumi on 12/4/02 and verified on 12/6/02 over
the phone.

Attachment # 1
Pump Model

Model Correlation

HS2.4S should be noted as


HS2.4S-52

LB2-400 should be noted as


LB-480-52 and LB-480A-52

LB3-750

LSC should be noted as


LSC1.4S-51

LSR should be noted as


LSR2.4S-51

Rated Volt

Rated Current

HS2.4S

110 , 220/230/240

5.5 , 2.7/2.6/2.6

HS2.4S-52

110 , 220/230/240

5.5 , 2.7/2.6/2.6

HSZ2.4S-52

110 , 220/230/240

5.5 , 2.7/2.6/2.6

LB2-400

110 , 220/230/240

6.2 , 3.1/2.9/2.7

LB-480-52

110 , 220/230/240

6.2 , 3.1/2.9/2.7

LB-480A-52

110 , 220/230/240

6.2 , 3.1/2.9/2.7

LBZ-480-52

110 , 220/230/240

6.2 , 3.1/2.9/2.7

LB3-750

110 , 220/230

13.9 , 6.7/7.1

LSC

110 , 220/230/240

8.0 , 4.6/3.9/4.2

LSC1.4S-51

110 , 220/230/240

6.2 , 3.1/2.9/2.7

LSR

110 , 220/230/240

6.2 , 3.1/2.9/2.7

LSR2.4S-51

110 , 220/230/240

6.2 , 3.1/2.9/2.7

TRF No.: 6335241C

Tsurumi (America), Inc.

page 4 of 71

Report No. 3035083


Revised: August 23, 2011

REVISION SUMMARY - The following changes have been made to this Report:
Date/
Proj # Off ID:
05/27/2011

Project Handler/
Page:
Reviewer:
S. La

100403326DEN
W. Shore

08/23/2011
NC-DEN

S. La
W. Shore

Item:

Description of Change

--

Added revision date

--

--

67

24.1

Revised and added the correction models chart


(attachment #1)
Added revision table and updated sample
nameplate
Add alternate water level probe

--

Update standard

--

Deleded models: HS2.4S-61 is now LB-480A-52,


and LB3-750 is now LB3-750-50

Copy of marking plate

TRF No.: 6335241C

Tsurumi (America), Inc.

page 5 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

GENERAL CONDITIONS FOR THE TESTS

Result - Remark

Verdict

Tests performed according to Cl. 4, e.g. nature of

supply, sequence of testing, etc.


4.7

4.8.1

Temperature of liquid is maintained between

See test data sheets for

30 C and 35 C, if relevant (EN 60 335-2-41:96)

details.

For a.c. only, tested at rated frequency

60Hz

For a.c./d.c., tested at the most unfavourable

Rated for a.c. alternating

supply (EN 60 335-1:94)

voltage only.

Appliances not marked with rated frequency,

Frequency is marked on each

tested with 50 Hz (EN 60 335-1:94)

unit.

Appliances for a.c. with frequency range of 50 to

See test data sheets for

60 Hz, tested with 50 or 60 Hz, the most

details.

(EN 60 335-1:94)

unfavourable (EN 60 335-1:94)


4.101

Pumps are tested as portable appliances, unless

Pumps are tested as portable.

Noted

Not stationary pumps.

Noted

they are intended to be fixed (EN 60 335-2-41:96)


4.102

Stationary pumps having a three-phase motor


which does not incorporate a protective device
are installed with an appropriate device, in
accordance with the instructions
(EN 60 335-2-41:96)

TRF No.: 6335241C

Tsurumi (America), Inc.

page 6 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

CLASSIFICATION

6.1

Submersible pumps for use in swimming pools

Not for use when persons are

when persons are in the pool shall be of Class III

in the pool.

with a rated voltage < 12 V (EN 60 335-2-41:96) . :


Other submersible pumps for use in water and

Class I

Not aquarimum pumps.

Class I

Other pumps shall be of Class I, II or III

Pumps are considered

(EN 60 335-2-41:96)

portable.

other conducting liquids shall be of Class I or


Class III (EN 60 335-2-41:96)
However, aquarium pumps may be of Class II
(EN 60 335-2-41:96)
Portable pumps for cleaning and other
maintenance of swimming pools shall be of
Class I or Class III (EN 60 335-2-41:96)

6.2

Protection against harmful ingress of water


Submersible pumps shall be IPX8

Pumps are IPX8. Will be

(EN 60 335-2-41:96)

labeled as such.

Portable pumps for cleaning and other

IPX8.

Other pumps shall be at least IPX4

Not applicable. Pumps are

(EN 60 335-2-41:96)

submersible.

maintenance of swimming pools shall be at least


IPX7 (EN 60 335-2-41:96)

TRF No.: 6335241C

Tsurumi (America), Inc.

page 7 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

MARKING

7.1

Rated voltage or voltage range (V) ...................... : Voltage marking provided.

Single-phase appliances: 230 V covered

Models are rated not more

(EN 60 335-1:94)

than 230 V.

Multi-phase appliances: 400 V covered

Not rated for multiple phases

AC

(EN 60 335-1:94)
Nature of supply

Rated frequency or frequency range (Hz) ............ : Frequency marked.

Rated input or rated current

Rated current provided.

Manufacturer's or responsible vendor's name,

Tsurumi Pump

Model or type reference

Model designation provided.

Symbol for Class II

Class I

IP number

IPX8 added.

trademark or identification mark

Pumps having a rated power input exceeding 50 W shall be marked with


(EN 60 335-2-41:96):
- the minimum total head, in metres, if greater

Markings added.

Markings added.

- the direction of rotation, for three-phase motors

Single phase only, not three

(EN 60 335-2-41:96)

phase.

Warning for stationary appliances

Not considered stationary.

Warning placed in vicinity of terminal cover

Single source of supply.

7.3

Range of rated values correctly marked

Single voltage rating.

7.4

Voltage setting clearly discernible

Not adjustable

7.5

Marking of rated input for each rated voltage

Single rated voltage

Marking for upper and lower limits of rated input

Single rated voltage.

7.6

Correct symbols used

Correct symbols used.

7.7

Correct connection diagram, fixed to the

Power supply cord attached.

than zero (EN 60 335-2-41:96)


- the maximum operating depth, in metres with a
minimum of 1 m (EN 60 335-2-41:96)

7.2

appliance

TRF No.: 6335241C

Tsurumi (America), Inc.

page 8 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

7.8

Not for type Z attachment:


Terminal marked.

- marking of earthing terminals

Earth terminal marked.

- marking not placed on removable parts

Markings not on removable

- marking of terminals for the neutral conductor


(N)

parts.

7.9

- marking of terminal for single-pole protective

Not intended for permanent

device

connection to fixed wiring.

Marking or placing of switches which may cause a No exterior switches.

hazard
7.10

Indications of switches and regulating devices by

No exterior switches.

No exterior switches.

use of figures, letters or other


The figure 0 indicates only OFF position, unless
no confusion with the OFF position
7.11

Indication for direction of adjustment of controls

No such controls

7.12

Instructions for safe use provided

Instruction provided.

Appliances incorporating batteries which contain

No batteries

materials hazardous to the environment:


statement in the instructions how to remove,
scrap and dispose of the battery safely
(EN 60 335-1:94)
Statement in the instructions that the appliance

must be disconnected from the supply


(EN 60 335-1:94)
The instructions for use of Class I portable pumps for cleaning and other
maintenance of swimming pools shall include the substance of the following
(EN 60 335-2-41:96):
- the pump must not be used when people are in

Statement added to the

the water (EN 60 335-2-41:96)

instructions manual

- the pump must be supplied through a residual

Statement added to the

current device (RDC) with a rated residual

instructions manual.

operating current not exceeding 30 mA


(EN 60 335-2-41:96)

TRF No.: 6335241C

Tsurumi (America), Inc.

page 9 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

7.12.1

Sufficient details for installation or maintenance

Maintenance instructions

supplied

provided.

The instructions for installation shall give full

Installation instructions

information for installation of Class I pumps for

provided.

operating swimming pools as specified


(EN 60 335-2-41:96)
The instructions for installation shall give full

Not classified as Class III.

Not classified as Class II.

The instructions for installation shall state that

Instructions added to the

pumps for outdoor fountains, garden ponds and

manual.

information for Class III swimming pool pumps as


specified (EN 60 335-2-41:96)
The instructions for installation shall give full
information for fixed Class II pumps as specified
(EN 60 335-2-41:96)

similar places have to be supplied through a RCD


(operating current not exceeding 30 mA)
(EN 60 335-2-41:96)
The instructions for installations shall state the

Instructions added to the

informations for pumps with a rated power input

manual.

exceeding 50 W and the remark concerning


pollution of the liquid as specified
(EN 60 335-2-41:96)
Additional information for installation of stationary Not classified as stationary.

pumps having a three-phase motor not


incorporating a protective device as specified
(EN 60 335-2-41:96)
7.12.2

Means for disconnection with contact separation

Not classified as stationary.

Not classified as stationary.

at least 3 mm
Stationary appliance with supply cord and plug:
statement in the instructions that the appliance is
so positioned that the plug is accessible
(EN 60 335-1:94)

TRF No.: 6335241C

Tsurumi (America), Inc.

page 10 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

7.12.3

Insulation in contact with parts exceeding 50 K;

Not intended for permanent

instruction

connection to a fixed wiring

system.
7.12.4

7.12.5

Information with regard to building-in:


- dimensions of space

Not a built-in appliance

- dimensions and position of support

Not a built-in appliance

- ventilation openings

Not a built-in appliance

- connection/interconnection plug accessible

Not a built-in appliance

Replacement cord, type X attachment

Not Type X attachment.

Replacement cord, type Y attachment

Statement added to the

instructions manual

7.13

Replacement cord, type Z attachment

Not Type Z attachment.

Instructions and other texts in official language

Instructions will be translated

into the language of the


country where it will be sold.
7.14

Marking easily legible and durable

Pumps already certified by

CSA. Reliability of markings


already evaluated.
7.15

Marking on a main part

Markings are riveted to main

enclosure.
Marking clearly discernible from outside

Clearly discernable from

outside.
Stationary appliance: name or trademark and

Not classified as a stationary

model or type reference visible after installation

appliance.

Indication for switches and controls in vicinity of

No switches or controls.

No replaceable thermal link or

components; not on removable parts if misleading


7.16

Marking of a possible replaceable thermal link or

fuse link clearly visible with regard to replacing the fuse link
link

TRF No.: 6335241C

Tsurumi (America), Inc.

page 11 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

PROTECTION AGAINST ACCESSIBILITY TO LIVE PARTS

8.1

Adequate protection against accidental contact

All live parts are totally

with live parts

enclosed and protected

Verdict

against accidental contact.


8.1.1

All positions; detachable parts removed

No detachable parts.

Removal of lamps: protection against contact with No lamps.

live parts
Use of test finger: no contact with live parts

Test finger cannot touch live

parts.
8.1.2

Use of test pin: no contact with live parts

Class I equipment.

No heating elements.

No such accessible parts.

- extra-low d.c. voltage: not exceeding 42,4 V

No such accessible parts.

- or separated from live parts by protective

No such accessible parts.

No such accessible parts.

No such accessible parts.

No such accessible parts.

(EN 60 335-1:94)
8.1.3

Use of test probe: no contact with live parts of


visible glowing heating elements

8.1.4

Accessible part not considered live if:


- extra-low a.c. voltage: peak values not
exceeding 42,4 V

impedance, d.c. current not exceeding 2 mA


- or separated from live parts by protective
impedance, a.c. peak value not exceeding 0,7 mA
- for peak value 42,4 V up to and including 450 V
capacitance not exceeding 0,1 F
- for peak value 450 V up to and including 15 kV
capacitance not exceeding 0,1 F
8.1.5

Live parts protected at least by basic insulation before installation or assembly


(checked by inspection and the test of 8.1.1) (EN 60 335-1:94):
- built-in appliances

Not a built in appliance.

- fixed appliances

Not a fixed appliance.

- separate units

No separate units

TRF No.: 6335241C

Tsurumi (America), Inc.

page 12 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

8.2

Class II appliances and constructions adequately

No Class II construction.

No Class II construction.

protected against accidental contact with basic


insulation and metal parts separated from live
parts with only basic insulation
Only possible to touch parts separated from live
parts by double or reinforced insulation
Appliances with batteries replaceable by the user, No batteries used..

basic insulation between live parts and the inner


surface of the battery compartment adequate
(EN 60 335-1:94)
If appliance can be operated without batteries:

No Class II construction.

double or reinforced insulation used


(EN 60 335-1:94)

10

POWER INPUT AND CURRENT

10.1

Power input at rated voltage and normal operating Input power not specified.

temperature not deviating from rated input by


more than shown in table; measured power input
(W); rated input (W); deviation ............................. :
10.2

Current at normal operating temperature not

See test data sheets

deviating from rated current by more than shown


in table; measured current at rated voltage under
normal operation (A); rated current (A); deviation :

TRF No.: 6335241C

Tsurumi (America), Inc.

page 13 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

11

HEATING

11.1

No excessive temperatures in normal use

See test data sheets.

11.2

Placing and mounting of appliance as described

Noted.

11.3

Temperature rises determined by thermocouples

Thermocouples and

or resistance method

resistance method

Heating appliances are operated at 1,15 times

Not a heating appliance.

Motor-operated appliances operated under

Operated at 0,94 x rated

normal operation at most unfavourable voltage

voltage and 1,06 x rated

between 0,94 and 1,06 times rated voltage

voltage.

Combined appliances operated under normal

Not a combined appliance.

Noted.

Noted.

Protective devices do not operate

Thermostat did not operate

Sealing compound not flowing out

No sealing compound

Temperatures not exceeding values in table 3

See test data sheets

11.4

Result - Remark

Verdict

rated power input


11.5

11.6

operation at most unfavourable voltage between


0,94 and 1,06 times rated voltage
11.7

Operation duration corresponding to the most


unfavourable conditions of normal use
Pumps are operated until steady conditions are
established (EN 60 335-2-41:96)

11.8

(EN 60 335-1:94)

13

LEAKAGE CURRENT

13.1

Leakage current not excessive and electric

Pump operated at 1,06 times

strength adequate

rated voltage.

Leakage current measured by means of circuit

Noted.

Leakage current measurements

See test data sheets

Electric strength test of insulation

See test data sheets

13.2

described in Annex G

13.3

No breakdown during the test

TRF No.: 6335241C

Tsurumi (America), Inc.

page 14 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

15

MOISTURE RESISTANCE

15.1

Enclosure provides the degree of moisture

Result - Remark

Verdict

See test data sheets

protection according to classification of appliance


(EN 60 335-1:94)
15.1.1

Appliance subjected to test as specified

Withstand electric strength test specified in 16.3

No trace of water on insulation which can result in

a reduction of distances and clearances below


values specified in 29.1

15.1.2

Submersible pumps are immersed for 24 h in

Maximum depth is 30 m. See

water as specified (EN 60 335-2-41:96)

test data sheets

Hand-held appliance turned continuously through

Not a hand-held appliance.

Not a built-in appliance.

See 15.1.1, immersed in water

the most unfavourable positions during the test


Built-in appliance installed according to the
manufacturer's instruction
Other appliances tested as specified

for 24h
15.2

Spillage of liquid does not affect the electrical

Not subject to spillage of liquid

insulation

in normal use

Overfilling test with additional amount of liquid (l) :

Withstand electric strength test in 16.3

No trace of water on insulation which can result in

reduction of distances and clearances below


values specified in 29.1
15.3

Humidity treatment for 48 h

Submersible pumps are not

subjected to humidity test


Withstanding the test of Cl. 16
Submersible pumps are not subjected to this test

N
Noted.

(EN 60 335-2-41:96)

16

LEAKAGE CURRENT AND ELECTRIC STRENGTH

TRF No.: 6335241C

Tsurumi (America), Inc.

page 15 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

16.1

No excessive leakage current and adequate

Noted.

insulation and electric strength (tests 16.2 and


16.3)
16.2

Leakage current measurements

See test data sheets.

16.3

Electric strength tests (values in table 5)

See test data sheets.

17

OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED


CIRCUITS
No excessive temperatures in transformer or

No transformers.

No transformers.

No transformers.

No transformers.

associated circuits in event of short-circuits likely


to occur in normal use
Appliance supplied with 1,06 or 0,94 times rated
voltage and the most unfavourable short-circuit or
overload likely to occur in normal use applied
Temperature rise of insulation of the conductors
of safety extra-low voltage circuits not exceeding
the relevant value specified in table 3 by more
than 15 K
Temperature of the winding not exceeding the
value specified in table 6

19

ABNORMAL OPERATION

19.1

The risk of fire or mechanical damage under

Passed overload and locked

abnormal or careless operation obviated

rotor test.

Compliance is also checked by the test of

Abnormal operation test. See

Cl. 19.101 (EN 60 335-2-41:96)

test data sheets

Electronic circuits so designed and applied that a

No electronic circuits.

Stalling test by locking the rotor if the locked rotor Locked rotor test. See

fault will not render the appliance unsafe


19.7

torque is smaller than the full load torque or

Appendix D for test procedure.

locking moving parts (EN 60 335-1:94)

See test data sheets.

Locked rotor, motor capacitors open circuited or

See test data sheets.

short-circuited, if required

TRF No.: 6335241C

Tsurumi (America), Inc.

page 16 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Appliances with timer or controller supplied with

No timer or controller.

Verdict

rated voltage for each of the tests, for a period


equal to the maximum period allowed
Test period at rated voltage (s or min) or until

Until steady state conditions

Noted

steady state conditions established ..................... : established


Winding temperatures not exceeding limiting

See test data sheets.

Not three phase.

Not a series motor.

Not a series motor.

No electronic circuits

temperature; type of appliance; insulation class;


measured temperature (C) ................................. :
19.8

Three-phase motors operated at rated voltage


with one phase disconnected

19.10

Series motor operated at 1,3 times rated voltage


for 1 min
Parts not ejected from the appliance during test
(EN 60 335-1:94)

19.11

Electronic circuits, compliance checked by


evaluation of the fault conditions specified in
19.11.2 for all circuits or parts of circuits, unless
they comply with the conditions specified in
19.11.1

19.11.1

Before applying the fault conditions a) to f) in 19.11.2, it is checked if circuits or


parts of circuit meet both of the following conditions:
- the electronic circuit is a low-power circuit, that

No electronic circuits.

- the protection against electric shock, fire hazard, No electronic circuits

is, the maximum power at low-power points does


not exceed 15 W according to the tests specified

mechanical hazard or dangerous malfunction in


other parts of the appliance does not rely on the
correct functioning of the electronic circuit

TRF No.: 6335241C

Tsurumi (America), Inc.

page 17 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

19.11.2

Fault conditions applied one at a time, the appliance operated under conditions
specified in Cl. 11, but supplied at rated voltage, the duration of the tests as
specified:
a) short-circuit of creepage distances and

No electronic circuits

b) open circuit at the terminals of any component

No electronic circuits

c) short-circuit of capacitors, unless they comply

No electronic circuits

No electronic circuits

e) failure of triacs in the diode mode

No electronic circuits

f) failure of an integrated circuit. In this case the

No electronic circuits

No electronic circuits

No electronic circuits

No electronic circuits

No electronic circuits

clearances between live parts of different


potential, if these distances are less than the
values specified in 29.1, unless the relevant part
is adequately encapsulated

with IEC 384-14 or 14.2 of IEC 65


d) short-circuit of any two terminals of an
electronic component, other than integrated
circuits. This fault condition is not applied
between the circuits of an optocoupler

possible hazardous situations of the appliance are


assessed to ensure that safety does not rely on
the correct functioning of such a component
During and after each test the following is checked:
- the temperature rise of the windings do not
exceed the values specified in table 6
- the appliance complies with the conditions
specified in 19.13
- live parts not accessible to the test finger or test
pin as specified in Cl. 8
- any current flowing through protective
impedance not exceeding the limits specified in
8.14
If a conductor of a printed board becomes open circuited, the appliance is
considered to have withstood the particular test, provided all three of the following
conditions are met:

TRF No.: 6335241C

Tsurumi (America), Inc.

page 18 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

- the material of the printed circuit board

No electronic circuits

No electronic circuits

No electronic circuits

No electronic circuits

withstands the burning test of 20.1 of IEC 65


- any loosened conductor does not reduce the
creepage distances or clearances between live
part and accessible metal parts
- the appliance withstands the tests of 19.11.2
with open circuited conductor bridged
19.12

If the safety of the appliance for any of the fault


conditions specified in 19.11.2 depends on the
operation of a miniature fuse-link complying with
IEC 127, the test is repeated, measuring the
current flowing through the fuse-link; measured
current (A); rated current of the fuse-link (A) ........

19.13

During the tests the appliance does not emit

flames, molten metal, poisonous or ignitable gas


in hazardous amounts
Temperature rises not exceeding the values

shown in table 7
Enclosures not deformed to such an extent that

compliance with Cl. 8 is impaired


Appliance still operable and complying with 20.2

Appliance, other than Class III, withstands the electric strength test of 16.3,
however, the test voltage being:

19.101

- basic insulation: 1000 V

- supplementary insulation: 2750 V

- reinforced insulation: 3750 V

The pump is supplied at rated voltage and

Abnormal Operation Test.

operated for 7 h without liquid as specified

See test data sheets.

(EN 60 335-2-41:96)
If during the test the pump becomes inoperable, it Abnormal Operation Test.
is disconnected from the supply and filled with

See test data sheets.

water (EN 60 335-2-41:96)

TRF No.: 6335241C

Tsurumi (America), Inc.

page 19 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

20

STABILITY AND MECHANICAL HAZARDS

20.1

Adequate stability

Result - Remark

Verdict

Submersible pumps are not

subjected to the test


Tilting test through an angle of 10 (appliance

Submersible pumps are not

placed on an inclined plane/horizontal plane);

subjected to the test

appliance does not overturn


Tilting test repeated on appliances with heating

Submersible pumps are not

elements, angle of inclination increased to 15

subjected to the test

Possible heating test in overturned position;

Submersible pumps are not

temperature rise does not exceed values shown

subjected to the test

in table 7

20.2

Submersible pumps are not subjected to the test

Submersible pumps are not

(EN 60 335-2-41:96)

subjected to the test

Moving parts adequately arranged or enclosed as Moving parts are enclosed

to provide protection against personal injury


Protective enclosures, guards and similar parts

Need tools to disassemble the

are non-detachable

enclosure and/or guards.

Adequate mechanical strength and fixing of

No damage after impact test

All moving parts are enclosed.

All moving parts are enclosed

protective enclosures
Self-resetting thermal cut-outs and overcurrent
protective devices not causing a hazard, if
unexpectedly reclosed
Not possible to touch dangerous moving parts
with test finger

TRF No.: 6335241C

Tsurumi (America), Inc.

page 20 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

21

MECHANICAL STRENGTH

Result - Remark

Verdict

Appliance has adequate mechanical strength and No damage after impact test.

is constructed as to withstand rough handling


No damage after three blows applied to various

No damage.

No damage after impact test

No damage after impact test

First numeral is not marked.

parts of the enclosure, impact energy 1,0 0,05 J


(EN 60 335-2-41:96)
If necessary, supplementary or reinforced
insulation subjected to the electric strength test of
16.3
If necessary, repetition of groups of three blows
on a new sample

22

CONSTRUCTION

22.1

Appliance marked with the first numeral of the IP


system: relevant requirements of IEC 529 are
fulfilled

22.2

Stationary appliance: means to provide all-pole disconnection from the supply


provided, the following means being available:
- a supply cord fitted with a plug

Not stationary pumps.

- a switch complying with 24.3

Not stationary pumps.

- a statement in the instruction sheet that a

Not stationary pumps.

- an appliance coupler

Not stationary pumps.

Single-phase Class I appliance with heating

Not stationary pumps. No

elements, intended to be permanently connected

heating elements.

disconnection incorporated in the fixed wiring is to


be provided

to fixed wiring, incorporating single-pole switches


or single-pole protective devices for the
disconnection of the heating element(s): the
switches/devices being connected in the phase
conductor (EN 60 335-1:94)
22.3

Appliance provided with pins: no undue strain on

No pins utilized.

socket-outlets

TRF No.: 6335241C

Tsurumi (America), Inc.

page 21 of 71

Report No. 3035083

EN 60 335-2-41
Clause

22.4

Requirement

Result - Remark

Verdict

Applied torque not exceeding 0,25 Nm

No pins utilized.

Appliance for heating liquids and appliance

Not for heating liquids; no

causing undue vibration not provided with pins for such pins utilized.
insertion into socket-outlets
22.5

No risk of electric shock when touching the pins

See test results.

See clause 15

Not a Class II appliance.

Not a Class II appliance.

Adequate safeguards against the risk of

Not steam producing devices.

excessive pressure in appliances provided with

Liquid or gases under

steam-producing devices

pressure are not used in

of the plug
22.6

Electrical insulation not affected by condensing


water or leaking liquid
Electrical insulation of Class II appliances not
affected in case of a hose rupture or seal leak
Compliance is checked by inspection and for
pumps of Class II by the test with removed seal
from the shaft of the pump as specified
(EN 60 335-2-41:96)

22.7

normal operation.
22.8

Electrical connections not subject to pulling during No compartments may be

cleaning of compartments to which access can be accessed without the use of a


gained without the aid of a tool, and which are

tool.

likely to be cleaned in normal use


22.9

Insulation, internal wiring, windings, commutators

Oil is contained in a separate

and slip rings not exposed to oil, grease or similar compartment.


substances
Adequate insulating properties of oil or grease to

which insulation is exposed


22.10

Location or protection of reset buttons of non-self- No non-self-resettig controls.

resetting controls is so that accidental resetting is


unlikely

TRF No.: 6335241C

Tsurumi (America), Inc.

page 22 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

22.11

Reliable fixing of non-detachable parts which

Secured by multiple

provide the necessary degree of protection

fasterners. No snap-in devices

against electric shock, moisture or contact with

used.

moving parts
Obvious locked position of snap-in devices used

No snap-in devices.

No deterioration of the fixing properties of snap-in No snap-in devices.

for fixing such parts

devices used in parts which are likely to be


removed during installation or servicing
Tests

Parts cannot be removed by a

fingernail probe. See above.


22.12

Handles, knobs etc. fixed in a reliable manner

Handles adequately fixed.

Fixing in wrong position of handles, knobs etc.

No exterior switches or

indicating position of switches or similar

controls

components not possible


Axial force 15 N applied to parts, the shape of

which being so that an axial pull is unlikely to be


applied
Axial force 30 N applied to parts, the shape of

which being so that an axial pull is likely to be


applied
22.13

22.14

Unlikely that handles, when gripped as in normal

Handles are away from high

use, make the operators hand touch parts having

temperature parts. No

a temperature rise exceeding the value specified

temperature rise

for handles which are held for short periods only

measurement needed.

No ragged or sharp edges creating a hazard for

No sharp edges observed.

No exposed pointed ends of self tapping screws

No self tapping screws

etc., liable to be touched by the user in normal

observed.

the user in normal use, or during user


maintenance

use or during user maintenance


22.15

Storage hooks and the like for flexible cords

No storage hooks for cord

smooth and well rounded

provided.

TRF No.: 6335241C

Tsurumi (America), Inc.

page 23 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

22.16

Automatic cord reels cause no undue abrasion or No cord reels provided.

Verdict

damage to the sheath of the flexible cord, no


breakage of conductors strands, no undue wear
of contacts
Cord reel tested with 6000 operations, as

specified
Electric strength test of 16.3, voltage of 1000 V

applied
22.17

Spacers not removable from the outside by hand

No such spacers utilized.

No direct contact observed.

or by means of a screwdriver or a spanner


22.18

Current-carrying parts and other metal parts


resistant to corrosion under normal conditions of
use
Direct contact between copper and aluminium or
their alloys is to be avoided (EN 60 335-2-41:96)

22.19

Driving belts not used as electrical insulation

No driving belts

22.20

Direct contact between live parts and thermal

No thermal insulation

Wood, cotton, silk, ordinary paper and fibrous or

Wood, cotton, silk, ordinary

hygroscopic material not used as insulation,

paper and fibrous or

unless impregnated

hygroscopic material not used

insulation effectively prevented, unless material


used is non-corrosive, non-hygroscopic and noncombustible
22.21

as insulation
22.22

Asbestos not used in the construction of the

Asbestos not used in the

appliance

construction of the appliance

Asbestos is used, but the liberation of dust of

Asbestos not used in the

impregnated asbestos or of asbestos fibres into

construction of the appliance

the surrounding air adequately prevented


22.23

Oils containing polychlorinated biphenyl (PCB) not Oils containing polychlorinated


used

biphenyl (PCB) not used

TRF No.: 6335241C

Tsurumi (America), Inc.

page 24 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

22.26

The insulation between parts operating at safety

No SELV

No protective impedances

Not a class II appliance

Not a class II appliance

No such parts

so constructed that they cannot be replaced in an No such parts

extra-low voltage and other live parts complies


with the requirements for double or reinforced
insulation
22.27

Parts connected by protective impedance


separated by double or reinforced insulation

22.28

Metal parts of Class II appliances conductively


connected to gas pipes or in contact with water:
separated from live parts by double or reinforced
insulation

22.29

Class II appliances permanently connected to


fixed wiring so constructed that the required
degree of protection against electric shock is
maintained after installation

22.30

Parts serving as supplementary or reinforced


insulation fixed so that they cannot be removed
without being seriously damaged, or

incorrect position, and so that if they are omitted,


the appliance is rendered inoperable or manifestly
incomplete
22.31

Creepage distances and clearances over

No supplement or reinforced

supplementary and reinforced insulation not

insulation

reduced below values specified in 29.1 as a result


of wear
Creepage distances and clearances over

No supplement or reinforced

supplementary or reinforced insulation not

insulation

reduced to less than 50% of values specified in


29.1 if wires, screws etc. becomes loose

TRF No.: 6335241C

Tsurumi (America), Inc.

page 25 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

22.32

Supplementary and reinforced insulation

No supplement or reinforced

designed or protected against deposition of dirt or insulation


dust
Ceramic material not tightly sintered, similar

No such ceramics or beads

material or beads alone not used as

used.

supplementary or reinforced insulation


(EN 60 335-1:94)
Supplementary insulation of natural or synthetic

No supplement or reinforced

rubber resistant to ageing, or arranged and

insulation

dimensioned so that creepage distances are not


reduced below values specified in 29.1

22.33

Oxygen bomb test at 70C for 96 h and 16 h at

No supplement or reinforced

room temperature

insulation

Conductive liquids which are or may become

Not in direct contact with live

accessible in normal use are not in direct contact

parts

with live parts


Conductive liquids are not in direct contact with

No class II constructions.

basic insulation or reinforced insulation in Class II Metal enclosures, grounded


constructions
Conductive liquids in contact with live parts, not in No conductive liquids in

22.34

direct contact with reinforced insulation

contact with live parts.

Shafts of operating knobs, handles, levers etc.

No shafts of operating knobs,

not live, unless the shaft is not accessible when

handles, levers etc.

the part is removed

TRF No.: 6335241C

Tsurumi (America), Inc.

page 26 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

22.35

Handles, levers and knobs, held or actuated in

Handle used for lifting only,

normal use, not becoming live in the event of an

not held in normal use.

insulation fault

Connected directly to metal

exterior.
Such parts being of metal, and their shafts or

Need construction details.

Not stationary appliances.

Handles continuously held in the hand in normal

Handle used for lifting only,

use are so constructed that when gripped as in

not held continuously in

normal use, the operators hand is not likely to

normal use

fixings are likely to become live in the event of an


insulation fault, they are either adequately
covered by insulation material, or their accessible
parts are separated from their shafts or fixings by
supplementary insulation
This requirement does not apply to handles,
levers and knobs on stationary appliances other
than those of electrical components, provided
they are either reliably connected to an earthing
terminal or earthing contact, or separated from
live parts by earthed metal
22.36

touch metal parts, unless they are separated from


live parts by double or reinforced insulation
22.37

Capacitors in Class II appliances not connected to Not a Class II appliance

accessible metal parts, unless complying with


22.42
Metal casings of capacitors in Class II appliances Not a Class II appliance

separated from accessible metal parts by


supplementary insulation, unless complying with
22.42
22.38

Capacitors not connected between the contacts of No such connections.

a thermal cut-out
22.39

Lamp holders only used for the connection of

No lampholders

lamps

TRF No.: 6335241C

Tsurumi (America), Inc.

page 27 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

22.40

Motor-operated appliances and combined

The requirement is not

appliances, intended to be moved while in

applicable to submersible

operation or which have accessible moving parts, pumps and submerged pumps
are fitted with a switch to control the motor
(EN 60 335-1:94)
The requirement is not applicable to submersible

Noted

pumps and submerged pumps


(EN 60 335-2-41:96)
The actuating member of this switch easily visible No such switch

and accessible (EN 60 335-1:94)


22.Z1

Appliance enclosure not shaped and decorated

Obviously not a toy.

No such compounds used.

No mercury switches

No protective impedance

so that the appliance is likely to be treated as a


toy by children (EN 60 335-1:94)
22.Z2

Fully halogenated chlorofluorocarbons (CFC's)


not used (EN 60 335-1:94)

22.41

Mercury switches mounted according to the


requirement

22.42

Protective impedance consisting of at least two


separate components
Values specified in 8.1.4 not exceeded if any one

of the components is short-circuited or open


circuited
22.43

Appliances adjustable for different voltages,

Not adjustable for different

accidental changing of the setting of the voltage

voltages

unlikely to occur
22.101

Pumps shall withstand the static liquid pressure

Submersible pumps.

occurring in normal use as specified, submersible


pumps and submerged pumps are not subjected
to this test (EN 60 335-2-41:96)
The pressure test is carried out for 1 min at a

pressure of 1,2 times the pressure occurring at


maximum total head (m) (EN 60 335-2-41:96) .... :

TRF No.: 6335241C

Tsurumi (America), Inc.

page 28 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

22.102

The material of the pump shall not be affected by

Intended to pump water. Metal

the liquid for which the pump is intended if a

is suitably protected against

hazard could result (EN 60 335-2-41:96)

corrosion.

Submersible pumps and submerged pumps shall

Lubricants are contained in

be constructed so that pollution of liquid by

separate area. Liquid does not

lubricants is prevented as far as possible

enter the pump interior.

22.103

Verdict

(EN 60 335-2-41:96)
22.104

Submersible pumps and submerged pumps

Handles provided.

No plastic enclosures.

having a mass exceeding 3 kg shall be


constructed so that means for hoisting can be
attached (EN 60 335-2-41:96)
22.105

Class I submersible pumps having a plastic


enclosure shall be constructed so that leakage of
liquid into the motor does not result in a hazard
(EN 60 335-2-41:96)
After the specified test the accumulating water

shall come in contact with earthed metal before it


reaches live parts (EN 60 335-2-41:96)

23

INTERNAL WIRING

23.1

Wireways smooth and free from sharp edges

Wires protected against contact with burrs,

No burrs or cooling fins

cooling fins etc.

observed.

Wire holes in metal well rounded or provided with Well rounded or provided with
bushings

bushings.

Wiring effectively prevented from coming into

No wiring near moving parts.

contact with moving parts

TRF No.: 6335241C

Tsurumi (America), Inc.

page 29 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

23.2

Beads etc. on live wires cannot change their

No beads or similar ceramics

position, and are not resting on sharp edges or

used as insulation.

corners

23.3

Beads inside flexible metal conduits contained

No beads or similar ceramics

within an insulating sleeve

used as insulation.

Electrical connections and internal conductors

Connections not subjected to

movable relatively to each other not exposed to

movement relative to each

undue stress

other in normal use.

Flexible metallic tubes not causing damage to

No flexible metallic tubes

insulation of conductors

observed.

Open-coil springs not used

Open-coil springs not used.

Adequate insulating lining provided inside a coiled Open-coil springs not used.

spring, the turns of which touch one another


No damage after 10 000 flexings

No relative motion.

Electric strength test, 1000 V between live parts

No relative motion.

No bare wiring sufficiently rigid

and metal parts


23.4

Bare internal wiring sufficiently rigid and fixed

and fixed.
23.5

23.6

The basic insulation of internal wiring withstanding Internal wiring is part of motor
the electrical stress likely to occur in normal use

assembly. Declaration of

(EN 60 335-1:94)

comformity provided.

No breakdown when a voltage of 2000 V is

Internal wiring is part of motor

applied for 15 min between the conductor and

assembly. Declaration of

metal foil wrapped around the insulation

comformity provided.

Sleeving used as supplementary insulation on

No sleeving observed.

internal wiring retained in position by positive


means
23.7

23.8

Only the colour combination green/yellow used for Green/yellow conductors used
earthing conductors

for earthing conductors.

Aluminium wires not used for internal wiring

Copper conductors used.

TRF No.: 6335241C

Tsurumi (America), Inc.

page 30 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

23.9

No lead-tin soldering of stranded conductors

No such soldering observed.

where they are subject to contact pressure,


unless
clamping means so constructed that there is no

risk of bad contact due to cold flow of the solder

24

COMPONENTS

24.1

Components comply with safety requirements in

See declaration of comformity

relevant IEC standards (EN 60 335-1:1994)

for all components attached to

this report.
24.1.1

Capacitors likely to be subjected to the supply

No such components.

Small lampholders: compliance with requirements No such components.

mains voltage and used for radio interference


suppression or voltage dividing, comply with
Annex ZC (EN 60 335-1:94)

for E10 lampholders


Isolating transformers and safety isolating

No such components.

No such components.

No such components.

No such components.

No such components

No such components

transformers comply with IEC 742


Safety isolating transformers tested with the
appliance comply with Annex ZD
(EN 60 335-1:94)
Appliance couplers for IPx0 appliances:
compliance with IEC 320
Automatic controls: compliance with IEC 730,
unless tested with the appliance
Other appliance couplers: compliance with
IEC 309
Switches: compliance with IEC 1058, unless
tested with the appliance (EN 60 335-1:94)

TRF No.: 6335241C

Tsurumi (America), Inc.

page 31 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

24.1.2

Automatic controls complying with IEC 730: additional tests according to this
standard and 11.3.5 to 11.3.8 and Cl. 17 of IEC 730 as type 1 controls, the cycles
of operation being:
- thermostats: 10 000

No thermostats.

- temperature limiters: 1000

No such components

- self-resetting thermal cut-outs: 300

Pump tested by CSA for 15

days endurance test on the


thermal cut out.

24.1.3

- non-self-resetting thermal cut-outs: 30

No such components

- energy regulators: 3000 (EN 60 335-1:94)

No such components

- timers: 10 000 (EN 60 335-1:94)

No such components

For switches, the test of 17.2.7 of IEC 1058-1

No such components

Level switches are tested for 50 000 cycles of

No level switches on the

operation (EN 60 335-2-41:96)

models being evaluated.

Switches not separately tested and found to

No such components

No such components

No such components

No such components

carried out for 10 000 cycles of operation


(EN 60 335-1:94)

comply with IEC 1058-1 under conditions covering


those occurring in the appliance, comply with
Annex ZE (EN 60 335-1:94)
Switches for no-load-operation and operable only
with the aid of a tool, are not subjected to the
tests of Cl. 17 of IEC 1058-1 (EN 60 335-1:94)
This applies also to switches operated by hand,
and with interlock for no-load-operation
(EN 60 335-1:94)
Switches without this interlock subjected to the
test of 17.2.7 of IEC 1058-1 for 100 cycles of
operation (EN 60 335-1:94)

TRF No.: 6335241C

Tsurumi (America), Inc.

page 32 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

24.1.4

Components marked with their operating

Components used in the

characteristics are used in the appliance in

appliance in accordance with

accordance with these markings

their ratings.

Components which have to comply with other

All components have

standards are tested separately, according to the

declarations of comformity.

relevant standard
Components used within the limits of its marking,

Used within their ratings

tested in accordance with conditions occurring in


the appliance
Components not marked, or not used in

accordance with its marking, or no IEC standard


exists, tested under the conditions occurring in
the appliance
Components not mentioned in table 3 tested as

No such components

Voltage across capacitors in series with a motor

Capacitors are rated 270Vac,

winding does not exceed 1,1 times rated voltage,

32uF. Pumps are rated

when the appliance is supplied at 1,1 times rated

220Vac max.

part of the appliance


24.1.5

voltage under minimum load


List of components
24.2

See attached.

Noted

No switches or automatic controls in flexible cords

However, a level switch may be incorporated in

No level switch in models

an interconnection cord (EN 60 335-2-41:96)

being evaluated.

No devices causing the protective device in the

No such devices.

No thermal cut-outs which can be reset by

No thermal cut-outs which can

soldering

be reset by soldering.

Switch intended for all-pole disconnection of

No such switches.

fixed wiring to operate in the event of a fault in the


appliance

24.3

stationary appliances is directly connected to the


supply terminals, having a contact separation of
at least 3 mm in each pole

TRF No.: 6335241C

Tsurumi (America), Inc.

page 33 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

24.4

Plugs and socket-outlets for heating elements

No heating elements or extra

and extra-low voltage circuits, not

low votlage curcuits

interchangeable with plugs, and


socket-outlets or with connectors and appliance

inlets complying with IEC 83 or IEC 320,


respectively
24.5

Plugs and socket-outlets etc. for interconnection

No interconnection cords.

cords, not interchangeable with plugs and socketoutlets or connectors and appliance inlets
complying with IEC 83 or IEC 320, respectively, if
direct supply from the mains could give rise to a
hazard
24.6

Motors connected to the supply mains and having No motors operating having a
inadequate basic insulation for the rated voltage

working voltage under 42 V.

of the appliance, comply with the requirements of


Annex F
The components are listed on an appended table

25

SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS

25.1

Appliance not intended for permanent connection to fixed wiring, means for
connection to the supply:
- supply cord fitted with a plug

Supply cord and plug

provided.
- an appliance inlet having at least the same
degree of protection against moisture as required
for the appliance
- pins for insertion into socket-outlets
Submersible pumps, other than Class III, shall be Supply cord and plug
fitted with a supply cord and plug

provided.

(EN 60 335-2-41:96)

TRF No.: 6335241C

Tsurumi (America), Inc.

page 34 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

25.2

Appliance not provided with more than one

Single source of connection to

means of connection to the supply

supply provided.

Stationary appliance for multiple supply may be

Not a stationary appliance.

provided with more than one means of


connection, provided electric strength test of
1250 V for 1 min between each means of
connection causes no breakdown
25.3

Connection of supply wires for appliance intended Not intended for permanent
to be permanently connected to fixed wiring

connection to supply.

possible after the appliance has been fixed to its


support
Appliance provided with a set of terminals for the

Flexible supply cord and plug

connection of cables or fixed wiring, cross-

provided.

sectional areas specified in 26.2


Appliance provided with a set of terminals

Flexible supply cord and plug

allowing the connection of a flexible cord

provided.

Appliance provided with a set of terminals and

Flexible supply cord and plug

cable entries, conduit entries, knock-outs or

provided.

glands, allowing connection of appropriate type of


cable or conduit
Submersible pumps, other than Class III, shall be Flexible supply cord and plug

25.4

fitted with a flexible cord (EN 60 335-2-41:96)

provided.

Cable and conduit entries, rated current of

Flexible supply cord and plug

appliance not exceeding 16 A, dimensions

provided.

according to table 8 (EN 60 335-1:94)


Introduction of conduit or cable does not affect

Flexible supply cord and plug

the protection against electric shock or reduce

provided.

creepage distances and clearances below values


specified in 29.1

TRF No.: 6335241C

Tsurumi (America), Inc.

page 35 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

25.5

Method for assemble supply cord with the appliance:

Verdict

- type X attachment

Type Y attachment

- type Y attachment

Type Y attachment

Type Z attachment, is allowed for (EN 60 335-2-41:96):


- pumps having a rated power input < 100 W

Type Y attachment

- pumps for garden ponds (EN 60 335-2-41:96)

Type Y attachment

Type X attachment: specially prepared cord

Type Y attachment

Type X attachment not used for flat twin tinsel

Type Y attachment

Single flexible cord used.

(EN 60 335-2-41:96)

cord
25.6

Plugs fitted with only one flexible cord

Supply cords of single-phase portable appliances having a rated current not


exceeding 16 A, provided with a plug complying with the following Standard
Sheets of IEC 83 (EN 60 335-1:94):
- for Class I appliances: Standard Sheet C2b, C3b Information provided on the
or C4 (EN 60 335-1:94)

manual that a proper plug be


provided by the distributor.

- for Class II appliances: Standard Sheet C5 or

Not a Class II appliance.

- 227 IEC 52 for aquarium pumps and table

Not an aquarium or fountain

fountain pumps (EN 60 335-2-41:96)

pump.

- 245 IEC 57 for pumps for indoor use, except

Not for indoor use.

- 245 IEC 66 for pumps intended for outdoor use

Cord has declaration of

having a rated input > 1000 W, portable pumps

comformity. Proper for

having a mass > 5 kg (EN 60 335-2-41:96)

application.

- 245 IEC 66 for pumps intended for use in

Pumps not for use in

swimming pools (EN 60 335-2-41:96)

swimming pools

C6 (EN 60 335-1:94)
25.7

Appliance supply cord not lighter than:

table fountain pumps and aquarium pumps


(EN 60 335-2-41:96)

TRF No.: 6335241C

Tsurumi (America), Inc.

page 36 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

- 227 IEC 57 for fixed pumps for outdoor use

Not fixed or portable pump

having a rated power input < 1 kW and portable

with mass <5kg

pumps for outdoor use having a mass < 5 kg


(EN 60 335-2-41:96)
Temperature rise of external metal parts

No parts exceeding 75K. Not

exceeding 75 K, PVC cord not used

PVC cord used.

PVC cord used: appliance so constructed that the Rubber insulated. Not PVC

supply cord is not likely to touch external metal


parts in normal use

25.8

PVC supply cord appropriate for higher

Rubber insulated cord. Not

temperatures, type Y or type Z attachment used

PVC.

Nominal cross-sectional area of supply cords

LB2-400 (6.1 A): 1,00 mm

LB3-750 (11.5 A): 1,5 mm

according to table 9; rated current (A); cross-

sectional area (mm) (EN 60 335-1:94) ............... : HS2.4s-61 (5.4 A): 0,75mm
LSR2.4S-60 (6.1 A): 1 mm
LSC-4 (7.0 A): 1,00 mm

P
2

The supply cord of submersible pumps intended

Supplied cords are a minimum

for outdoor use shall have a length of at least 10

of 10 m.

m (EN 60 335-2-41:96)
25.9

Supply cord not in contact with sharp points or

Proper bushing used. No

edges

sharp points or edges

observed.
25.10

25.11

Green/yellow core for earthing purposes in Class I Green/yellow conductors used

appliance

for earthing purposes

Conductors of supply cords not consolidated by

No such soldering observed.

No such soldering observed.

No damage observed.

lead-tin soldering where they are subject to


contact pressure, unless
clamping means so constructed that there is no
risk of bad contacts due to cold flow of the solder
25.12

Moulding the cord to part of the enclosure does


not damage the insulation of the supply cord

TRF No.: 6335241C

Tsurumi (America), Inc.

page 37 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

25.13

Inlet opening provided with a bushing, or is so

Inlet opening provided with a

constructed, that there is no risk of damage to the bushing, no risk of damage to


supply cord when introduced

the supply cord when


introduced

25.13.1

Inlet bushing so shaped as to prevent damage to

the supply cord


Inlet bushing not detachable
25.13.2

At inlet openings, the insulation between the conductor of a supply cord and the
enclosure of the appliance is consisting of the insulation of the conductor, and in
addition:
- for other appliances: at least two separate

Cord is double insuated

Cord is double insuated

insulations
Only one separate insulation is required if the
enclosure at the inlet opening is of insulating
material
The separate insulation consists of:
- the sheath of a supply cord at least equivalent to Cord is CE. Declaration of
that of a cord complying with IEC 227 or 245

comformity provided.

- a lining or bushing of insulating material

Cord is CE. Declaration of

complying with the requirements of 29.2 for

comformity provided.

supplementary insulation
25.14

Supply cords adequately protected against

Strain relief consist of a metal

excessive flexing

mechanical assembly over a

rubber tube that souround the


cord on one type. The second
type uses an additional
support for the cable so it
wont move. No movement of
cable during operation at the
strain relief.
All portable pumps are subjected to the decribed

See above

flexing test (EN 60 335-2-41:96)


Flexing test; applied force (N); number of flexings :

TRF No.: 6335241C

Tsurumi (America), Inc.

page 38 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

The test does not result in:


- short-circuit between the conductors

- breakage of more than 10% of the strands of

any conductor
- separation of the conductor from its terminal

- loosening of any cord guard

- damage, within the meaning of the standard, to

the cord or the cord guard


- broken strands piercing the insulation and

becoming accessible
25.15

Conductors of the supply cord relieved from

Cord anchorages utilized.

The cord cannot be pushed into the appliance to

Cords cannot be pushed back

such an extent that the cord or internal parts of

into pump.

strain, twisting and abrasion by use of cord


anchorages

the appliance can be damaged


Pull and torque test of supply cord, values shown

100N, 0.35 Nm

in table 10: pull (N); torque (Nm) (not on


automatic cord reel) ............................................. :
Max. 2 mm displacement of the cord, and

conductors not moved more than 1 mm in the


terminals
Creepage distances and clearances not reduced

below values specified in 29.1


25.16

Cord anchorages for type X attachments so constructed and located that:


- replacement of the cord is easily possible

Type Y attachment

- it is clear how the relief from strain and the

Type Y attachment

- they are suitable for different types of cord

Type Y attachment

- cord cannot touch the clamping screws of cord

Type Y attachment

prevention of twisting are obtained

anchorage if these screws are accessible, unless


separated from

TRF No.: 6335241C

Tsurumi (America), Inc.

page 39 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

- accessible metal parts by supplementary

Type Y attachment

Type Y attachment

- at least one part of the cord anchorage securely Type Y attachment

insulation
- the cord is not clamped by a metal screw which
bears directly on the cord

fixed to the appliance, unless part of a specially


prepared cord
- screws which have to be operated when

Type Y attachment

- if labyrinths can be bypassed the test of 25.15 is Type Y attachment

replacing the cord do not fix any other


component, if applicable

nevertheless withstood
- for Class I appliances: they are of insulating

Type Y attachment

Type Y attachment

See 25.15.

material or are provided with an insulating lining,


unless a failure of the insulation of the cord does
not make accessible metal parts live
- for Class II appliances: they are of insulating
material, or if of metal, they are insulated from
accessible metal parts by supplementary
insulation
25.17

Adequate cord anchorages for type Y and Z


attachment

25.18

25.19

Cord anchorages only accessible with the aid of a Cord may only be fitted with

tool, or

the aid of a tool.

so constructed that the cord only can be fitted

Cord may only be fitted with

with the aid of a tool

the aid of a tool.

Type X attachment, glands not used as cord

Not type X

Tying the cord into a knot or tying the cord with

Cord not tied in a knot or

string not used

string used for strain relief.

Conductors of the supply cord for type Y and Z

Conductors of supply cord are

attachment adequately additionally insulated

adequately insulated..

anchorage in portable appliances

25.20

TRF No.: 6335241C

Tsurumi (America), Inc.

page 40 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

25.21

Space for supply cable for fixed wiring or supply

Type Y attachment.

For portable appliances, the uninsulated end of a

Cord anchorages prevent

conductor prevented from any contact with

contact with metal parts.

cord for type X attachment constructed to permit


checking of conductors with respect to correct
positioning and connection before fitting any
cover, no risk of damage, no contact with
accessible metal parts if a conductor becomes
loose, etc.

accessible metal parts, unless the end of the cord


is such that the conductors are unlikely to slip free
25.23

Interconnection cords comply with the

No interconnection cord.

If necessary, electric strength test of 16.3

No interconnection cord.

Interconnection cords not detachable without the

No interconnection cord.

Provided with supply cord;

requirements for the supply cord, except as


specified

25.24

aid of a tool

26

TERMINALS FOR EXTERNAL CONDUCTORS

26.1.1

Appliances with type X attachment and

appliances for connection to fixed wiring provided Type Y attachment.


with terminals in which connection is made by
means of screws, nuts or equally effective
devices
Screws and nuts serve only to clamp supply

Provided with supply cord;

conductors, except

Type Y attachment.

internal conductors, if so arranged that they are

Provided with supply cord;

unlikely to be displaced when fitting the supply

Type Y attachment.

conductors
26.1.2

For type X attachment soldered connections

Not Type X attachment.

used, the conductor so positioned or fixed that


reliance is not placed on soldering alone

TRF No.: 6335241C

Tsurumi (America), Inc.

page 41 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

Soldering alone used, barriers provided, creepage Not type X attachment

distances and clearances satisfactory if the


conductor becomes free
For type Y and Z attachment: soldered, welded,

Crimp splice connectors used

Class I appliance.

Class I appliance.

Type Y attachment.

Terminals only suitable for a specially prepared

No specially prepared cords

cord

used.

Terminals for the supply cord suitable for their

Terminals suitable for

purpose

intended function.

Terminals with screw clamping and screwless

No flat twin tinsel cords.

No observed damage.

crimped and similar connections used


For Class II appliances: the conductor so
positioned or fixed that reliance is not placed on
soldering, welding or crimping alone
For Class II appliances: soldering, welding or
crimping alone used, barriers provided, creepage
distances and clearances satisfactory if the
conductor becomes free
26.2

Terminals for type X attachment and for


connection to fixed wiring suitable for connection
of conductors with required cross-sectional area
according to table 11; rated current (A); nominal
cross-sectional area (mm) .................................. :

26.3

terminals not used for flat twin tinsel cords, unless


conductors ends fitted with a device suitable for
screw terminals
Pull test of 5 N to the connection
26.4

Terminals for type X attachment and those for connection to fixed wiring so fixed
that when tightening or loosening the clamping means:
- the terminal does not loosen

Not Type X attachment.

- internal wiring is not subjected to stress

Not Type X attachment.

- creepage distances and clearances are not

Not Type X attachment/

reduced below the values in 29.1

TRF No.: 6335241C

Tsurumi (America), Inc.

page 42 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

26.5

Terminals for type X attachment and for

Not Type X attachment.

Not Type X attachment.

No pillar type terminals.

Not for connection to fixed

connection to fixed wiring so constructed that the


conductor is clamped between metal surfaces
with sufficient contact pressure and without
damaging the conductor
26.6

Terminals for type X attachment, no special


preparation of conductors required, and so
constructed and placed that conductors prevented
from slipping out, except those with a specially
prepared cord and those for connection to fixed
wiring

26.7

Terminals of the pillar type constructed and


located as specified

26.8

Terminals for the connection to fixed wiring

located close to each other, including the earthing wiring.


terminal
26.9

Terminals for type X attachment accessible after

Not Type X attachment.

Terminals not accessible

removal of a cover or part of the enclosure


26.10

Terminals not accessible without the aid of a tool

without the aid of a tool


26.11

Terminals for type X attachment so located or

Not Type X attachment.

Not Type X attachment.

Not Type X attachment.

shielded that if a wire of a stranded conductor


escapes, no risk of accidental connection
between live parts and accessible metal parts,
and for Class II construction, between live parts
and metal parts separated from accessible metal
parts by supplementary insulation only
Stranded conductor test, 8 mm insulation
removed

27

PROVISION FOR EARTHING

TRF No.: 6335241C

Tsurumi (America), Inc.

page 43 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

27.1

Accessible metal parts of Class I appliances,

Accessible metal permanently

permanently and reliably connected to an earthing and reliably connected to


terminal

earthing terminal.

Earthing terminals not connected to neutral

Not connected to neutral

terminal

terminal.

Class 0, II and III appliance have no provision for

Class 1 appliance.

Screw clamping terminals comply with Cl. 26

Suitable terminals used.

Screwless terminals comply with IEC 998-2-2

No screwless terminals used.

Terminals used for the connection of external

No external equipotential

equipotential bonding conductors allow

bonding

earthing
27.2

(EN 60 335-1:94)

connection of conductors of 2,5 to 6 mm, and


do not provide earthing continuity between

different parts of the appliance


Conductors cannot be loosened without the aid of Conductors cannot be
a tool

loosened without the aid of a


tool

Clamping means adequately secured against

Star or lock washers used.

Not handheld appliance

No PCBs used.

No PCBs used.

No PCBs used.

Earth connection "made before" and "separated

Pins on attachement plug are

after" current-carrying connections

make first/break last type

accidental loosening
27.Z1

In hand-held appliances printed conductors of


printed circuit boards not used to provide earthing
continuity (EN 60 335-1:94)
In other appliances at least two tracks are used
with independent soldering points, and
the appliance complies with the requirements of
27.5 for each circuit, and
the material of the printed board complies with
IEC 249-2-4 or IEC 249-2-5

27.3

TRF No.: 6335241C

Tsurumi (America), Inc.

page 44 of 71

Report No. 3035083

EN 60 335-2-41
Clause

27.4

Requirement

Result - Remark

Verdict

Current-carrying conductors become taut before

Earthing conductor will be

earthing conductor, if the cord slips out of the

longer than the other

cord anchorage

conductors.

No risk of corrosion resulting from contact

Metals are compatible without

between metal of earthing terminal and other

risk of galvanic corrosion.

metal
Adequate resistance to corrosion of coated or

Metals are compatible without

uncoated parts providing earthing continuity, other risk of galvanic corrosion.


than parts of a metal frame or enclosure
Parts of steel providing earthing continuity

No such steel parts observed.

All such parts are suitably

provided at the essential areas with an


electroplated coating, thickness at least 5 m
Adequate protection against rusting of parts of

coated or uncoated steel, only intended to provide protected against corrosion.


or transmit contact pressure
In case of aluminium alloys precautions taken to

Aluminum and copper not

avoid risk of corrosion

observed in contact with each

other.
27.5

Low resistance of connection between earthing

Low resistance provided.

See test data sheets.

terminal and earthed metal parts


Resistance not exceeding 0,1 at the specified
low-resistance test

TRF No.: 6335241C

Tsurumi (America), Inc.

page 45 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

28

SCREWS AND CONNECTIONS

28.1

Fixings and electrical connections withstand

Electrical connections capable

mechanical stresses

of withstanding the stress of

normal use.
Screws not of soft metal liable to creep, such as

No zinc or aluminum screws

zinc or aluminium

observed.

Diameter of screws of insulating material min.

No screws of insulating

3 mm

material

Screws of insulating material not used for any

No screws of insulating

electrical connection

material.

Screws transmitting electrical contact only

No screws screw into metal of

screwing into metal

electrical contact.

Screws not of insulating material if their

No screws of insuating

replacement by a metal screw can impair

material

supplementary or reinforced insulation


Type X attachment, screws to be removed for

Not Type X attachment.

Screws and nuts transmitting contact pressure

No damage of fixings or

subjected to torque test as specified, applying

electrical connections

torque as shown in table 12

observed.

The test is not carried out on screws and nuts

Single fasteners used. No

transmitting contact pressure for earthing

damage of fixings or electrical

replacement of supply cord, or for users


maintenance, not of insulating material if their
replacement by a metal screw can impair basic
insulation

continuity provided at least two screws or nuts are connections observed.


used (EN 60 335-1:94)
28.2

Contact pressure not transmitted through

Electrical connections are not

insulating material liable to shrink or distort,

transmitted through insulating

unless shrinkage or distortion compensated

material likely to shrink or

distort.

TRF No.: 6335241C

Tsurumi (America), Inc.

page 46 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

This requirement does not apply to electrical

No such circuits.

No such screws used.

No such screws used.

Thread-cutting (self-tapping) screws not used if

No such screws likely to be

they are likely to be operated by the user or

used by the operator.

connections in circuits carrying a current not


exceeding 0,5 A (EN 60 335-1:94)
28.3

Space-threaded (sheet metal) screws only used


for the connection of current-carrying parts if they
clamp these parts directly in contact with each
other
Thread-cutting (self-tapping) screws not used for
electrical connection of current-carrying parts,
unless generating a full form standard machine
screw thread

installer unless the thread is formed by a swaging


action
Use of thread-cutting and space-threaded screws No such screws used.

for earthing continuity according to specification


Screws for current-carrying mechanical

Star washer used.

Multiple fasteners used.

Rivets for current-carrying connections subject to

No rivets used for current-

torsion secured against loosening

carrying connections.

connection or screws providing earthing continuity


secured against loosening
28.4

Screws and nuts making mechanical connection


between different parts of the appliance, and also
making electrical connection or providing earthing
continuity secured against loosening

TRF No.: 6335241C

Tsurumi (America), Inc.

page 47 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

29

CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH

Verdict

INSULATION
29.1

Creepage distances and clearances not less than (see appended table)

specified in table 13 (EN 60 335-1:94)


Resonance voltage between the point where a

Creepage and clearances

winding and a capacitor are connected together

evaluated according to a

and metal parts separated from live parts by basic resonant voltage of 220V
insulation only, creepage distances and

(50/60Hz) and 110V (50/60Hz)

clearances not less than the values specified for

for the different models.

the value of the voltage produced by the


resonance (EN 60 335-1:1994)
Values increased by 4 mm in case of reinforced

insulation when resonance voltage


29.2

Distances through insulation not less than 1,0 mm 1.32mm basic

for supplementary insulation, and 2,0 mm for


reinforced insulation
29.2.1

Supplementary insulation applied in thin sheet

No thin sheet form insulation

form, other than mica or similar scaly material,

obseved.

consists of at least two layers, each of the layers


withstands the electric strength test of 16.3 for
supplementary insulation
Reinforced insulation applied in thin sheet form,

No thin sheet form insulation

other than mica or similar scaly material, consists


of at least three layers, and any two of the layers
together withstand the electric strength test of
16.3 for reinforced insulation

TRF No.: 6335241C

Tsurumi (America), Inc.

page 48 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

29.2.2

Supplementary or reinforced insulation

No such insulation obseved.

No such insulation observed.

No non-metallic materials

inaccessible and does not exceed the maximum


permissible temperature values
Supplementary or reinforced insulation, after
conditioning as specified, withstands the electric
strength test as specified in 16.3, both at the oven
temperature and room temperature

30

RESISTANCE TO HEAT, FIRE AND TRACKING

30.1

See Annex H

which might cause the


appliance to fail.
Relevant external parts of non-metallic material

Parts supporting live parts and parts providing

supplementary or reinforced insulation sufficiently


resistant to heat
Ball-pressure test with a force of 20 N, diameter

of impression not exceeding 2 mm


External parts: at 75 C

Parts supporting live parts: at 125 C

Parts providing supplementary or reinforced

insulation: temperature (C) ................................. :


30.2

Relevant parts of non-metallic material

No non-metallic parts.

adequately resistant to ignition and spread of fire


30.2.1

Possible burning test of relevant parts according

to Annex J
Glow-wire test of Annex K made at temperature

550 C

TRF No.: 6335241C

Tsurumi (America), Inc.

page 49 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

30.2.2

Appliances operated while attended, parts of

Not necessarily operated while

insulating material supporting connections

attended.

carrying a current exceeding 0,5 A in normal


operation, subjected to the glow-wire test of
Annex K at 650 C
30.2.3

Appliances operated while unattended, possible

Not to be operated while

bad-connection test according to Annex L

unnatended.

Glow-wire test of Annex K made at 850 C

(EN 60 335-1:94)
Possible needle-flame test according to Annex M
30.2.4

Parts of non-metallic material within a distance of

N
No such material observed.

Relevant insulating material have adequate

Insulating materials are part of

resistance to tracking

CE marked components.

50 mm from parts not withstanding the tests of


30.2.2 or 30.2.3, subjected to the needle-flame
test of Annex M
30.3

Tracking test at 175 V according to Annex N

Tracking test at 250 V according to Annex N

No hazard other than fire, tracking test at 175 V

according to Annex N, and in addition needleflame test of surrounding parts according to


Annex M
Possible needle-flame test of non-metallic

material

31

RESISTANCE TO RUSTING
Relevant ferrous parts adequately protected

Painted

against rusting

32

RADIATION, TOXICITY AND SIMILAR HAZARDS

TRF No.: 6335241C

Tsurumi (America), Inc.

page 50 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

Appliance does not emit harmful radiation

Appliance does not present a toxic or similar

hazard

ANNEX A, NORMATIVE REFERENCES


The annex contains a list of standards which are

Noted

referred to, and thus become part of, this


standard

ANNEX C, AGEING TEST ON MOTORS


Test carried out when doubt with regard to the

classification of the insulating system of a motor


winding

ANNEX D, ALTERNATIVE REQUIREMENTS FOR PROTECTED MOTOR


UNITS
Void (EN 60 335-1:94)

ANNEX E, MEASUREMENT OF CREEPAGE DISTANCES AND CLEARANCES


Methods of measuring creepage distances and

Noted

clearances, specified in 29.1, indicated in 10


different cases

TRF No.: 6335241C

Tsurumi (America), Inc.

page 51 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

ANNEX F, MOTORS NOT ISOLATED FROM THE SUPPLY MAINS AND

Verdict

HAVING BASIC INSULATION NOT DESIGNED FOR THE RATED VOLTAGE


OF THE APPLIANCE
Motors having a working voltage not exceeding

Motors rated > 42V

42 V, not being isolated from the supply mains,


and having basic insulation not designed for the
rated voltage of the appliance are tested
according to this annex
All clauses of this standard apply, unless

otherwise specified in this annex


F.8

Protection against accessibility to live parts

F.11.8

Temperature rise of the body of the motor, where

in contact with insulating material, not exceeding


values in table 3 for the relevant insulating
material
F.16

Leakage current and electric strength

F.19

Abnormal operation

F.19.101

Appliance operated at rated voltage with each of the following defects:


- short-circuit of the terminals of the motor,

including any capacitor incorporated in the motor


circuit
- open circuit of the supply to the motor

- open circuit of any shunt resistor during

operation of the motor


F.22

Construction

F.22.101

Class I appliance incorporating a motor supplied

by a rectifier circuit, the d.c. circuit being insulated


from accessible parts of the appliance by double
or reinforced insulation

TRF No.: 6335241C

Tsurumi (America), Inc.

page 52 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

ANNEX G, CIRCUIT FOR MEASURING LEAKAGE CURRENTS

Verdict

A suitable circuit for measuring leakage currents

Noted

is shown

ANNEX H, SELECTION AND SEQUENCE OF THE TESTS OF CLAUSE 30

ANNEX J, BURNING TEST


The burning test is made in accordance with

No non-metallic materials

IEC 707, and method FH is used

used as insulation

Category FH3 applies, the maximum burning rate No non-metallic materials


being 40 mm/min

Noted

used as insulation

ANNEX K, GLOW-WIRE TEST


The glow-wire test is made in accordance with IEC 695-2-1 (clause numbers
between parentheses refer to IEC 695-2-1)

(4)

(5)

(10)

Description of test apparatus: the last paragraph

No non-metallic materials

before the note is replaced

used as insulation

Severities: the duration of application of the tip of

No non-metallic materials

the glow-wire to the specimen being (30 1) s

used as insulation

Observations and measurements: item c) does

No non-metallic materials

not apply

used as insulation

TRF No.: 6335241C

Tsurumi (America), Inc.

page 53 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

ANNEX L, BAD-CONNECTION TEST WITH HEATERS

Verdict

The bad-connection test with heaters is made in accordance with IEC 695-2-3
(clause numbers between parentheses refer to IEC 695-2-3)
(3)

General description of the test: additions

No heaters

concerning crimped connections


(4)

Description of test apparatus: replacements of

some of the test specifications and the first


paragraph of the note
(6)

Severities: the duration of application of the test

power being (30 1) min


(8)

Test procedure: 8.6 replaced

(11)

Information to be given in the relevant

specification: item h), the first dashed paragraph,


does not apply

ANNEX M, NEEDLE-FLAME TEST


The needle-flame test is made in accordance with IEC 695-2-2 (clause numbers
between parentheses refer to IEC 695-2-2)

(4)

Description of the apparatus: the sixth paragraph

Noted.

Noted.

Noted.

Noted.

is replaced
(5)

Severities: the duration of application of the test


flame is (30 1) s

(8)

Test procedure: some changes in the test


specifications

(10)

Evaluation of the test results: addition in the test


specification

TRF No.: 6335241C

Tsurumi (America), Inc.

page 54 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

ANNEX N, PROOF TRACKING TEST

Result - Remark

Verdict

The proof tracking test is made in accordance with IEC 112 (clause numbers
between parentheses refer to IEC 112)
(3)

Test specimen: the last sentence of the first

paragraph does not apply


(5)

Test apparatus: some changes in the subclauses

(6)

Procedure: adjustments of the test specifications

ANNEX P, SEVERITY OF DUTY CONDITIONS OF INSULATING MATERIAL


WITH RESPECT TO THE RISK OF TRACKING
Recognition of different duty conditions with

Noted.

respect to the risk of tracking

ZA

ANNEX ZA, SPECIAL NATIONAL CONDITIONS

7.12

DENMARK: requirements regarding marking tag

No tag required. Proper plug

of power supply cord and connecting of earthing

provided with instructions.

wire
19.5

NORWAY: the test is also applicable to

No heating element

No electric circuits

No heating elements

appliances intended to be permanently connected


to fixed wiring
19.11.2

AUSTRIA: requirements regarding appliances


having circuits which under fault conditions may
cause earth-leakage currents having a d.c.
component exceeding 5 mA and exceeding 20%
of the total earth-leakage

22.2

FRANCE, NORWAY: The second paragraph of


this subclause dealing with single-phase Class I
appliances with heating elements is not applicable
due to the supply system

TRF No.: 6335241C

Tsurumi (America), Inc.

page 55 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

25.6

BELGIUM, FRANCE, GREECE, UNITED

Proper plug will be provided by

KINGDOM: plugs according to Standard

distributor

Sheet C2b not allowed


AUSTRIA, GERMANY, FINLAND, ICELAND,

Proper plug will be provided by

IRELAND, ITALY, LUXEMBOURG,

distributor

NETHERLANDS, NORWAY, PORTUGAL,


SPAIN, SWEDEN, SWITZERLAND, UNITED
KINGDOM: plugs according to Standard C3b not
allowed
DENMARK: Supply cords of single-phase portable appliances having a rated
current not exceeding 10 A provided with a plug according to the following:
Class I appliances: Section 107-2-DI Standard

Proper plug will be provided by

Sheet DK2-1a

distributor

For appliances covered by a Part 2 of EN 60 335, Proper plug will be provided by


also plugs in accordance with IEC 83, Standard

distributor

Sheet C2b, C3b or C4 are allowed


Class II appliances: IEC 83, Standard Sheet C5

Proper plug will be provided by

or C6

distributor

Stationary single-phase appliances, having a

Proper plug will be provided by

rated current not exceeding 10 A, and provided

distributor

with a plug, the plug is in accordance with the


requirements above
Multi-phase appliances and single-phase appliances having a rated current
exceeding 10 A, and provided with a plug, the plug is in accordance with the
requirements below:
Class I appliances: Section 107-2-D1, Standard

Proper plug will be provided by

Sheet DK6-1a/EN 60 309-2, Standard Sheet 2-II,

distributor

2-IV
Class II appliances: Section 107-2-D1, Standard

Proper plug will be provided by

Sheet DK6-1a/2-II, 2-IV

distributor

IRELAND: plug is in accordance with Standard

Proper plug will be provided by

Sheets B1 (15A), B2 and C2b

distributor

TRF No.: 6335241C

Tsurumi (America), Inc.

page 56 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

SPAIN: Appliances having a rated current not exceeding 6 A, provided with a plug
complying with UNE 20 315:
for Class I appliances: Figure 7C

for Class II appliances: Figure 15A

Class I appliances having a rated current not

exceeding 16 A, provided with a plug complying


with Standard UNE 20 315 Figure 7B
SWITZERLAND: supply cords of portable household and similar electrical
appliances, rated current not exceeding 10 A, provided with a plug complying with
SEV 1011 or IEC 884-1 and one of the following dimension sheets:
SEV 6532-2:1991 plug type 15 3P+N+PE

250/400 V, 10 A
SEV 6532-2:1991 plug type 11 L+N 250 V, 10 A

SEV 6532-2:1991 plug type 12 L+N+PE 250 V,

10 A
UNITED KINGDOM: plug according to Standard

Sheet B2 or C5 used (refer to Annex ZB)


IRELAND, UNITED KINGDOM: replacement of

Noted

figures (rated current/cross-sectional area) in the


table

ZB

ANNEX ZB, A-DEVIATIONS

SWITZERLAND: information about batteries

No batteries

7.1

ITALY: the voltage is 220 V/380 V

Not single phase

SPAIN: the voltages are 127 V/220 V and

220 V/380 V
7.12

IRELAND: information about required label

Not for domestic use

attached to the supply cord, concerning the colour


code of the wires

TRF No.: 6335241C

Tsurumi (America), Inc.

page 57 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

22.22

GERMANY: the amount of asbestos in the mass

No asbestos observed.

FINLAND: certain types of asbestos not used

No asbestos observed.

SWEDEN: components containing mercury not

No mercury observed.

containing asbestos not exceeding 0,1%

24

used
25.6

UNITED KINGDOM: regulations concerning plugs Not domestic appliance

to be fitted to domestic appliances

ZC

ANNEX ZC, CAPACITORS


The following clauses and subclauses of

No such capacitors used for

IEC 384-14:1981 apply to capacitors likely to be

radio frequency interference

permanently subjected to the supply mains

and permanently connected to

voltage and used for radio interference

supply mains voltage.

suppression or for voltage dividing purposes with


the following modifications
4

Terminology

4.3

Applicable, capacitors of Class X tested as


capacitors of Class X2

4.4

Applicable

Marking

6.1

Items a) and b) applicable

Schedules for qualification approval tests

8.1

Table II, group 0, group 2 and group 3 applicable as follows:


- group 0: subclauses 10.1, 10.2, 11.1 and 11.3
- group 2: subclause 12.10
- group 3: subclause 12.11

10.1

Visual examination and check of dimensions


Applicable

10.2

Applicable for the marking required by 6.1a) and


b)

11

Electrical tests

TRF No.: 6335241C

Tsurumi (America), Inc.

page 58 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

11.1

Applicable

11.3

Only table VI applies; climatic category is -/-/21;

Result - Remark

Verdict

the values for test A apply; capacitors in heating


appliances, the values for test B or C apply
12

Environmental test

12.10

Applicable; only insulation resistance and voltage


proof are checked (see table X)

12.11

Applicable with 12.11.2 and 12.11.6 modified as follow


Capacitors are subjected to an impulse voltage test if they are incorporated:
- in appliances liable to be operated while
unattended
- in other appliances where they are liable to
remain under electric stress while the ON/OFF
switch or control is in the OFF position,
irrespective of the position of the plug in the
socket-outlet
The wave form of the impulse is 1,2/50 with a
peak value of 2,5 kV
Alternatively, the test is carried out with an
impulse voltage having any front time but with a
time to half value not exceeding 100 ###s
The peak value of the impulse voltage adjusted
by a suitable means such as an impulse proof
capacitor of low inductance and having a
capacitance similar to that of the capacitor under
test
No flashover or visible damage when the impulse
voltage is applied 3 times with at least 1 s
between the impulses

12.11.6

See Note

ZD

ANNEX ZD, SAFETY ISOLATING TRANSFORMERS

TRF No.: 6335241C

Tsurumi (America), Inc.

page 59 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Safety isolating transformers, tested with the

No transformer used.

Verdict

appliance, comply with this standard and the


following additional requirements
7

Marking and instructions

7.1

Marking of transformers for specific use:


- name
- trademark/identification mark of manufacturer or
responsible vendor
- model or type reference

17

Overload protection of transformers and associated equipment


The temperature limits specified for the windings
do not apply to fail-safe transformers
Such transformers comply with 14.5 of EN 60 742

22

Construction

22.501

Subclause 8.6 of EN 60 742 applicable

29

Creepage distances, clearances and distances through insulation

29.1

The distances specified in Table XV of


EN 60 742, items 1a, 1c and 2 apply

ZE

ANNEX ZE, SWITCHES


Switches tested with the appliance comply with this standard and the following
clauses of IEC 1058-1, as modified
- the tests of IEC 1058-1 carried out under the

No switches used.

conditions occurring in the appliance, unless


- otherwise specified, the tests are carried out on
the switch incorporated in the appliance
- before being tested in the appliance, switches
are operated 20 times without load

TRF No.: 6335241C

Tsurumi (America), Inc.

page 60 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Marking and documentation


Switches are not required to be marked except,

Result - Remark

No switches.

Verdict

that incorporated switches shall be marked with


the manufacturer's name or trademark and the
type reference
13

Mechanism
Applicable

15

Insulation resistance and electric strength

15.1

Not applicable

15.2

Not applicable

15.3

Applicable for full disconnection micro-

disconnection
17

Endurance
Applicable, at the end of the tests, temperature

rise of the terminals not increased by more than


30 K
20

Clearances, creepage distances and distances through insulation


Applicable for creepage distances and clearances

for live parts of different potential only, as stated


in table 18 for operational insulation, and across
full disconnection and micro-disconnection

ZF

ANNEX ZF, informative


IEC and CENELEC code designations for flexible H07RN-F

cords

TRF No.: 6335241C

Tsurumi (America), Inc.

page 61 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

10

TABLE: input deviation measurements

input deviation dP of/at:

11.8

Result - Remark

Irated (A)

I (A)

dI

Verdict

required dI Remark

TABLE: temperature rise measurements

room temperature t1 (C) ..................................... :

21.086

---

room temperature t2 (C) ..................................... :

21.35

---

test voltage (V) ..................................................... :

122V

---

temperature rise dT of part/at:

dT (K)

required dT (K)

Winding temperature rise measurements


temperature rise dT of winding:

Motor winding

11.8

R1()

2.343

R2 ()

2.58

dT (K)

25.6

required

Insulation

dT (K)

class

65

TABLE: temperature rise measurements


room temperature t1 (C) ..................................... :

---

room temperature t2 (C) ..................................... :

---

test voltage (V) ..................................................... :

---

temperature rise dT of part/at:

dT (K)

required dT (K)

Winding temperature rise measurements


temperature rise dT of winding:

13.2

R1 ()

R2 ()

dT (K)

required

insulation

dT (K)

class

TABLE: leakage current measurements at operating temperature

TRF No.: 6335241C

Tsurumi (America), Inc.

page 62 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

---

heating appliances: at 1,15 times maximum rated


input (W) .............................................................. :
motor-operated and combined appliances: at

---

1,06 times rated voltage (V) ................................. :


leakage current I between:

13.3

required I (mA)

TABLE: electric strength measurements at operating temperature

test voltage applied between:

16.2

I (mA)

test voltage (V)

breakdown

TABLE: leakage current measurements

at 1,06 times rated voltage (V) ............................. : 122V

---

leakage current I between:

I (mA)

required I (mA)

Neutral open, normal polarity

0.13

0.75

Neutral open, reverse polarity

0.13

0.75

Neutral closed, normal polarity

0.05

0.75

Neutral closed, reverse polarity

0.075

0.75

16.3

TABLE: insulation resistance measurements

insulation resistance R between:

17

N
R (M)

required R (M)

TABLE: overload protection, temperature rise measurements

at 1,06-0,94 times rated voltage (V) ..................... :

---

room temperature (C) ......................................... :

---

TRF No.: 6335241C

Tsurumi (America), Inc.

page 63 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

temperature T and temperature rise dT of part/at:

Result - Remark

Verdict

required T

dT

Required

(C)

(C)

(K)

dT (K)

TRF No.: 6335241C

Tsurumi (America), Inc.

page 64 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

19.7

TABLE: abnormal operation, temperature and temperature rise

Verdict

measurements
room temperature t1 (C) ..................................... :

---

room temperature t2 (C) ..................................... :

---

temperature rise T C of part/at:

T (C)

required T (C)

Winding temperature rise measurements


insulation class ..................................................... :
windings measured

--T (C)

required T (C)

TRF No.: 6335241C

Tsurumi (America), Inc.

page 65 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

24.1
Component

Result - Remark

Verdict

TABLE: Model HS(Z)2.4S-52 components


Manufacturer

Type/model

Technical Data

Standard

conformity1)

Trademark
Power Cord

Mark(s) of

H07 RN-F

See attached

IEC 60245-4

CE, VDE

IEC 60332-1
IEC 60228
Attachment Plug

Will be
provided by
distributor

Motor Assembly

Leadership

HSE-2B or
HSE-2D

(Staring Capacitor,
Internal wiring and

See attached

IEC 60034-1

CE

IEC 600252
IEC 60034-11

thermal protector)
Strain Relief

Tsurumi

CE

) an asterisk indicates a mark which assures the agreed level of surveillance

TRF No.: 6335241C

Tsurumi (America), Inc.

page 66 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

24.1
Component

Result - Remark

Verdict

TABLE: Model LB3-750 components


Manufacturer

Type/model

Technical Data

Standard

conformity1)

Trademark
Power Cord

Mark(s) of

H07 RN-F

See attached

IEC 60245-4

CE, VDE

IEC 60332-1
IEC 60228
Attachment Plug

Will be
provided by
distributor

Motor Assembly

Aichi-Elec

LK-7

See attached

IEC 60034-1

(Staring Capacitor,

IEC 600252

Internal wiring and

IEC 60034-11

CE

thermal protector)
Strain Relief

Tsurumi

CE

) an asterisk indicates a mark which assures the agreed level of surveillance

TRF No.: 6335241C

Tsurumi (America), Inc.

page 67 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

Result - Remark

Verdict

Revised: May 27, 2011


24.1
Component

TABLE: Model LB(Z)-480-52 and LB-480A-52 components


Manufacturer

Type/model

Technical Data

Standard

conformity1)

Trademark
Power Cord

Mark(s) of

H07 RN-F

See attached

IEC 60245-4

CE, VDE

IEC 60332-1
IEC 60228
Attachment Plug

Will be
provided by
distributor

Motor Assembly

Leadership

(Staring Capacitor,

LSE-1B or LSE- See attached

IEC 60034-1

1D

IEC 600252

Internal wiring and

CE

IEC 60034-11

thermal protector)
Strain Relief

Tsurumi

CE

Water Level Probbe Shinwa

EL-2P-100 or

100-120 or 200-

(for Model LB-

Kogyo

EL-2P-200

240Vac, 7A

480A-52) alternate

Co.,Ltd

) an asterisk indicates a mark which assures the agreed level of surveillance

TRF No.: 6335241C

Tsurumi (America), Inc.

page 68 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

24.1
Component

Result - Remark

Verdict

TABLE: Model LSR2.4S-51 components


Manufacturer

Type/model

Technical Data

Standard

conformity1)

Trademark
Power Cord

Mark(s) of

H07 RN-F

See attached

IEC 60245-4

CE, VDE

IEC 60332-1
IEC 60228
Attachment Plug

Will be
provided by
distributor

Motor Assembly

Leadership

(Staring Capacitor,
Internal wiring and

LSE-1B or LSE- See attached

IEC 60034-1

1D

IEC 600252

CE

IEC 60034-11

thermal protector)
Strain Relief

Tsurumi

CE

) an asterisk indicates a mark which assures the agreed level of surveillance

TRF No.: 6335241C

Tsurumi (America), Inc.

page 69 of 71

Report No. 3035083

EN 60 335-2-41
Clause

Requirement

24.1
Component

Result - Remark

Verdict

TABLE: Model LSC1.4S-51 components


Manufacturer

Type/model

Technical Data

Standard

conformity1)

Trademark
Power Cord

Mark(s) of

H07 RN-F

See attached

IEC 60245-4

CE, VDE

IEC 60332-1
IEC 60228
Attachment Plug

Will be
provided by
distributor

Motor Assembly

Leadership

(Staring Capacitor,
Internal wiring and

LSE-1B or LSE- See attached

IEC 60034-1

1D

IEC 600252

CE

IEC 60034-11

thermal protector)
Strain Relief

Tsurumi

CE

) an asterisk indicates a mark which assures the agreed level of surveillance

TRF No.: 6335241C

Tsurumi (America), Inc.

29.1

page 70 of 71

Report No. 3035083

TABLE: creepage distance and clearance through insulation measurements

creepage (cr) and clearance (cl)


distance (mm):

Class III

other appliances, Uworking:

appliances
< 130 V
cr

between live parts of different polarity:


- if protected against deposition of
dirt
- if not protected against deposition
of dirt
- if lacquered or enamelled windings
between live parts and other metal
parts over basic insulation:

remark

130-250 V

250-440 V

cl

cr

cl

cr

cl

cr

cl

1,0

1,0

1,0

1,0

2,0

2,0

2,0

1,5

2,0

1,5

3,0

2,0
2,0 Between
10.28 10.28 phases
2,5
4,0
3,0

1,0

1,0

1,5

1,5

2,0

2,0

3,0

3,0

1,0

1,0

1,0

1,0

2,5

2,5

-,-

-,-

- if protected against deposition of


dirt:
. if of ceramic material or pure
mica and the like
. if of other material

1,5

1,0

1,5

1,0

3,0

2,5

-,-

-,-

- if not protected against deposition


of dirt
- if the live parts are lacquered or
enamelled windings

2,0

1,5

2,0

1,5

4,0

3,0

-,-

-,-

1,0

1,0

1,5

1,5

2,0

2,0

-,-

-,-

- at the end of tubular sheathed-type


heating elements

-,-

-,-

1,0

1,0

1,0

1,0

-,-

-,-

-,-

-,-

6,0

6,0

6,0

6,0

-,-

-,-

- for other live parts

-,-

-,-

8,0

8,0

8,0

8,0

-,-

-,-

between metal parts separated by

-,-

-,-

4,0

4,0

4,0

4,0

-,-

-,-

2,0

2,0

6,0

6,0

6,0

6,0

-,-

-,-

between live parts and other metal


parts over reinforced insulation
- if the live parts are lacquered or
enamelled windings

supplementary insulation
between live parts in recesses in the
mounting face of the appliance and
the surface to which it is fixed

TRF No.: 6335241C

Tsurumi (America), Inc.

30
part

page 71 of 71

Report No. 3035083

TABLE: ball-pressure tests

N
test temperature

impression diameter

(C)

(mm)

TRF No.: 6335241C