You are on page 1of 2

ACT20M Expansion

More Analog Functionality in a 6mm Wide Package


New!
Temperature and
Voltage/Current

For thermocouples,
RTDs and bipolar D.C.

Power Rail Option


Saves Installation Time

Choice of
Isolation/Conversion

No jumpers needed

Including low-cost
non-isolating models

Wide Temperature
Input Range

Global Approvals

E asy to set, with


DIP switches

Available with cULus and


Div 2 / Zone 2 approvals.

Lets Connect

www.weidmuller.com

Competitive Comparisons
Weidmuller
ACT20M

Phoenix Contact
MINI MCR

Red Lion
AIMA/IAMA/AFCM

Omron
K3FP Series

WAGO
Series 857

Screw / Tension

Screw

Screw / Tension

Screw

Screw

Tension

Power rail option

Yes

Yes

No

Yes

No

cULus, CE, DNV, GL


FM Div2, ATEX,
IECEx Zone 2
-25 to 70C

cULus, CE, GL

cULus, CE, GL

UL 508

CE, cULus, GL (pending)

Typ. FM Div2

Typ. FM Div2

None

Div 2

-20 to 60C

-20 to 60C

-20 to 65C

-20 to 70C (/50C)

2.5kV

1.5kV

1.5kV

1.5kV

2.5kV

Company

Approvals - Normal
Approvals - Hazloc
Ambient temperature
Isolation

Typical
Application

RTD
O/P
Input

4+20mA Output

Power
Supply

Control System

ACT20M-RTI-AO-S
+24Vdc

Availability

Process Vessel
Power Supply

The following products are available from stock:


Description

Function

Channel

Power

ACT20M-UI-AO-S

Universal input converter / isolator

Auxiliary

1176030000

ACT20M-CI-2CO-S

Current isolator / splitter

Auxiliary

1175990000

ACT20M-AI-2AO-S

Current or voltage isolator / splitter

Auxiliary

1176020000

Current or voltage isolator / converter

Auxiliary

1176000000

ACT20M-AI-AO-S

Part Number

Economy current or voltage isolator / converter

Auxiliary

1176010000

ACT20M-CI-CO-ILP-S

Passive current isolator

Input Loop

1176070000

ACT20M-2CI-2CO-ILP-S

Passive current isolator

Input Loop

1176080000

ACT20M-CI-CO-OLP-S

Current isolator

Output Loop Powered

1176040000

ACT20M-2CI-2CO-OLP-S

Current isolator

Output Loop Powered

1176050000

ACT20M-CI-CO-S

Current isolator

Auxiliary

1175980000

Bipolar current or voltage isolator / converter

Auxiliary

1375450000

Bipolar current or voltage isolator / splitter

Auxiliary

1375470000

ACT20M-TCI-AO-S

Thermocouple isolator / converter

Auxiliary

1375480000

ACT20M-RTI-AO-S

RTD isolator / converter

Auxiliary

1375510000

ACT20M-RTCI-CO-OLP-S

Thermocouple or RTD isolator / converter

Output Loop Powered

1435590000

ACT20M-RTI-CO-EOLP-S

RTD (non-isolating) converter

Output Loop Powered

1435610000

ACT20M-TCI-AO-E-S

Thermocouple (non-isolating) converter

Auxiliary

1375500000

ACT20M-RTI-AO-E-S

RTD (non-isolating) converter

Auxiliary

1375520000

ACT20-Feed-in-PRO-S

ACT20 Rail power feed / diode module

8965500000

ACT20 Rail power feed module

1282490000

ACT20M-AI-AO-E-S

ACT20M-BAI-AO-S
ACT20M-BAI-2AO-S

ACT20-Feed-in-BASIC-S

Information

Information is available for download on the web at www.weidmuller.com


Sales Tool

Description

Issue

LIT1126

ACT20M Datasheet

03/2014

Weidmuller, Canada

Weidmuller, Mexico

10 Spy Court
Markham, Ontario L3R 5H6
Telephone: (800) 268-4080
Facsimile: (877) 300-5635
Email: info1@weidmuller.ca
Website: www.weidmuller.ca

Blvd. Hermanos Serdn 698,


Col. San Rafael Oriente
Puebla, Puebla, Mexico
C.P. 72029
Telephone: 01 222 2686267
Facsimile: 01 222 2686219
Email: clientes@weidmuller.com.mx
Website: www.weidmuller.com.mx

www.weidmuller.com

Weidmuller, United States


821 Southlake Blvd.
Richmond, Virginia 23236
Telephone: (800) 849-9343
Facsimile: (804) 379-2593
Email: info@weidmuller.com
Website: www.weidmuller.com

03/14 2M LIT1127