Professional Documents
Culture Documents
4118111822
Wireless Service Provider Solutions
UMTS
Performance Management
Access Network Observation Counters
UMT/DCL/DD/0022 04.09/EN Standard June 2005
4118111822
UMTS
Performance Management
Access Network Observation Counters
Document number:
Document issue:
Document status:
Product release:
Date:
UMT/DCL/DD/0022
4118111822
04.09/EN
Standard
UMTS V 4.0
June 2005
Nortel Confidential
Publication history
PUBLICATION HISTORY
SYSTEM RELEASE UMTS V4.0
June 2005
Issue 04.09/EN Standard
Update for Post Channel Readiness
Resolution of the following CRs:
Q01050008
Q00862233
Q01033167
Q01033176
Q01034927
Q01039681
Q01122829
February 2005
Issue 04.06/EN Standard
Update for Channel Readness
November 2004
Issue 04.05/EN Standard
Update for Channel Readness
October 2004
Issue 04.04/EN Pre-standard
Update for Pre-Channel Readness
Resolution of the following CRs:
Q00892229
Q00891885
Q00862233
Q00831698
Q00982652
Nortel Confidential
Publication history
ii
June 2004
Issue 04.03/EN Preliminary
Update for Customer Readness after internal review
Resolution of the CR Q00892229
May 2004
Issue 04.01/EN Draft
Update for RAN V4.0
February 2004
Issue 03.05/EN Draft
Update for RAN V3.2
November 2003
Issue 03.04/EN Standard
Update for Channel Readness
Resolution of the following CRs:
Q00739038
Q00738613
May 2003
Issue 03.03/EN Preliminary
Update for Customer Readness after internal review
April 2003
Nortel Confidential
Publication history
iii
March 2003
Issue 03.01/EN Draft
Update for RAN V3.1
Nortel Confidential
Table of contents
iv
12
13
20
30
31
Handover counters
44
65
77
87
92
114
136
Paging counters
139
148
161
179
202
209
217
224
247
251
252
Nortel Confidential
Table of contents
260
Radio counters
269
280
RACH Counters
284
EEC counters
289
HSSPC counters
294
296
BTS IP counters
304
310
311
339
348
356
Index
359
Nortel Confidential
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
List of figures
vi
4
14
14
15
20
21
21
23
25
26
27
28
Nortel Confidential
List of tables
vii
18
31
31
32
33
34
35
35
36
36
38
38
39
39
40
41
41
42
42
44
44
45
46
46
47
48
48
49
50
50
51
52
52
53
54
54
55
56
56
57
Nortel Confidential
List of tables
viii
58
58
59
60
60
61
61
62
63
63
65
65
66
66
67
67
68
68
69
69
69
70
70
71
71
72
72
73
73
74
74
74
75
75
77
77
78
78
79
80
80
Nortel Confidential
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
List of tables
ix
81
82
83
83
84
84
85
85
86
87
87
88
88
89
90
90
92
93
93
94
94
95
96
97
98
99
99
100
100
101
101
102
102
103
104
105
106
106
107
108
108
109
Nortel Confidential
List of tables
109
110
111
111
112
114
115
115
116
117
118
119
119
120
121
122
123
123
124
125
126
127
127
128
129
130
130
131
131
132
133
133
134
134
135
136
136
136
137
Nortel Confidential
List of tables
xi
139
139
140
140
141
141
142
143
143
144
144
145
146
148
148
149
150
150
151
151
152
153
153
154
155
155
156
156
157
158
159
160
161
161
162
163
163
164
164
165
Nortel Confidential
List of tables
xii
165
166
166
167
167
168
169
169
170
171
172
172
173
174
175
175
176
177
177
178
179
180
180
181
182
183
183
184
185
186
186
187
188
188
189
189
Nortel Confidential
Table 239 Table 240 Table 241 Table 242 Table 243 Table 244 Table 245 Table 246 Table 247 Table 248 Table 249 Table 250 Table 251 Table 252 Table 253 Table 254 Table 255 Table 256 Table 257 Table 258 Table 259 Traffic)
Table 260 Traffic)
Table 261 Table 262 Traffic)
Table 263 Traffic)
Table 264 Table 265 Table 266 Table 267 Table 268 Traffic)
Table 269 Traffic)
Table 270 Table 271 Table 272 Table 273 Table 274 Table 275 Table 276 -
List of tables
xiii
190
191
191
192
192
193
194
194
195
196
196
197
198
198
199
200
200
202
202
203
203
204
204
204
205
205
206
206
207
207
208
209
209
210
211
211
212
213
Nortel Confidential
List of tables
Management)
Table 277 - VS.IurDrncRadioLinkReconfigurationPrepareUnsuccess. (RNSAP Radio Link
Management)
Table 278 - VS.IurDrncRadioLinkReconfigurationCancelSuccess. (RNSAP Radio Link
Management)
Table 279 - VS.IurDrncRadioLinkReconfigurationCommitSuccess. (RNSAP Radio Link
Management)
Table 280 - Iur Interface Connection counters
Table 281 - VS.IurSccpCnxSuccess. (Iur Interface Connection)
Table 282 - VS.IurSccpCnxUnsuccess. (Iur Interface Connection)
Table 283 - VS.IurAvgNbrInitSccpCnx.Avg (Iur Interface Connection)
Table 284 - VS.IurAvgNbrInitSccpCnx.Max (Iur Interface Connection)
Table 285 - VS.IurAvgNbrInitSccpCnx.Min (Iur Interface Connection)
Table 286 - VS.IurAvgNbrTermSccpCnx.Avg (Iur Interface Connection)
Table 287 - VS.IurAvgNbrTermSccpCnx.Max (Iur Interface Connection)
Table 288 - VS.IurAvgNbrTermSccpCnx.Min (Iur Interface Connection)
Table 289 - VS.IurEmittedSccpAbnormalDisconnects. (Iur Interface Connection)
Table 290 - VS.IurReceivedSccpAbnormalDisconnects (Iur Interface Connection)
Table 291 - User Plane Dedicated Channel Traffic counters
Table 292 - VS.DedicatedUplinkKbytesRlcSrb. (User Plane Dedicated Channel Traffic)
Table 293 - VS.DedicatedDownlinkKbytesRlcSrb. (User Plane Dedicated Channel Traffic)
Table 294 - VS.DedicatedUplinkPduRlcSrb. (User Plane Dedicated Channel Traffic)
Table 295 - VS.DedicatedDownlinkPduRlcSrb. (User Plane Dedicated Channel Traffic)
Table 296 - VS.DedicatedUplinkSduRlcSrb. (User Plane Dedicated Channel Traffic)
Table 297 - VS.DedicatedDownlinkSduRlcSrb. (User Plane Dedicated Channel Traffic)
Table 298 - VS.DedicatedUplinkMissingPduRlcSrb. (User Plane Dedicated Channel
Traffic)
Table 299 - VS.DedicatedDownlinkDiscardSduRlcSrb. (User Plane Dedicated Channel
Traffic)
Table 300 - VS.DedicatedDownlinkPaddingSduRlcSrb. (User Plane Dedicated Channel
Traffic)
Table 301 - VS.DedicatedUplinkKbytesRlcCsData. (User Plane Dedicated Channel
Traffic)
Table 302 - VS.DedicatedDownlinkKbytesRlcCsData. (User Plane Dedicated Channel
Traffic)
Table 303 - VS.DedicatedUplinkPduRlcCsData. (User Plane Dedicated Channel Traffic)
Table 304 - VS.DedicatedDownlinkPduRlcCsData. (User Plane Dedicated Channel
Traffic)
Table 305 - VS.DedicatedUplinkSduRlcCsData. (User Plane Dedicated Channel Traffic)
Table 306 - VS.DedicatedDownlinkSduRlcCsData. (User Plane Dedicated Channel
Traffic)
Table 307 - VS.DedicatedUplinkMissingPduRlcCsData. (User Plane Dedicated Channel
Traffic)
Table 308 - VS.DedicatedDownlinkDiscardSduRlcCsData. (User Plane Dedicated
Channel Traffic)
Table 309 - VS.DedicatedDownlinkPaddingSduRlcCsData. (User Plane Dedicated
Channel Traffic)
xiv
214
214
215
217
217
218
218
219
219
220
220
221
222
222
224
225
225
226
226
227
228
228
229
229
230
230
231
232
232
233
234
234
235
Nortel Confidential
Table 310 Table 311 Table 312 Table 313 Table 314 Table 315 Table 316 Traffic)
Table 317 Traffic)
Table 318 Traffic)
Table 319 Table 320 Table 321 Traffic)
Table 322 Traffic)
Table 323 Table 324 Table 325 Table 326 Table 327 Table 328 Table 329 Table 330 Table 331 Table 332 Table 333 Table 334 Table 335 Table 336 Table 337 Table 338 Table 339 Table 340 Table 341 Table 342 Table 343 Table 344 Table 345 Table 346 Table 347 Table 348 -
List of tables
xv
236
236
237
237
238
239
239
240
241
241
242
242
243
244
244
245
246
247
247
248
248
249
250
252
252
253
253
254
254
254
255
255
256
256
257
257
258
258
260
Nortel Confidential
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 -
List of tables
xvi
260
261
261
262
262
263
263
264
264
264
265
265
266
266
267
267
269
269
270
270
271
271
272
272
273
273
274
274
275
275
275
276
276
277
277
278
278
280
280
280
281
281
Nortel Confidential
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 -
List of tables
xvii
282
282
284
284
284
285
285
286
286
287
287
289
289
289
290
290
291
291
292
292
293
294
296
296
297
297
298
298
299
299
300
300
301
301
302
302
304
304
305
305
305
306
Nortel Confidential
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 -
List of tables
xviii
306
307
307
308
308
309
311
312
312
313
313
314
314
315
315
316
316
317
317
318
318
319
319
320
320
320
321
321
322
322
323
323
324
325
325
326
327
328
328
329
330
331
Nortel Confidential
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
Table
475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 -
List of tables
xix
332
332
333
334
335
335
336
337
337
339
339
340
340
341
341
342
343
343
344
344
345
345
345
346
346
349
351
352
354
357
358
Nortel Confidential
Example
Example
Example
Example
Example
Example
123456-
List of examples
xx
349
351
352
354
357
358
Nortel Confidential
Related publications
This publication is referenced in the Performance Management for Access Network
(UMT/DCL/DD/0021 or 411-8111-534) NTP that describes the Access Network applications of the
performance server and the associated data collected, and the process of data collection and
mediation.
How this publication is organized
In a continuous effort to improve the documentation, Nortel Networks is preparing the delivery of
document through the web. Web delivery leads to a new global organization of the Nortel Networks
technical publications.
The information is divided into modules, with each module containing elementary information such as
the procedure to replace a particular equipment or the description of a particular component.
The modules are designed to deliver just enough information to provide you with the solution
required to perform a particular task.
These modules will be delivered on CD-ROMs or through the web. You can access this information
by browsing, navigating from one module to another, or by using a search engine.
In its current version, this NTP has been written as a series of modules. The modules are arranged
one after the other in logical order and the table of contents helps you to access the right module.
This publication consists of the following modules:
"Road map to UTRAN documentation" presents the NTPs in the UTRAN documentation suite.
"What is new in Access Network Observation Counters" presents the changes and, or the new
features introduced for the UMTS04 release.
Nortel Confidential
"How Access Network observation counters are defined" provides information about the
counter definition template, counter types on the OAM GUI, and counter hierarchy.
"How Access Network observation counters are described" describes the Access Network
observation counters.
"RNC C-Node counter families" lists RNC C-Node counter families and presents their counters.
Each counter is described separately in a table, and these tables are arranged in alphanumerical
order.
"BTS counter families" lists BTS counter families and presents their counters. Each counter is
described separately in a table, and these tables are arranged in alphanumerical order.
"RNC PASSPORT Platform counter families" lists RNC Passport platform counter families and
presents their counters. Each counter is described separately in a table, and these tables are
arranged in alphanumerical order.
Vocabulary conventions
For a list of UMTS terms used in this NTP, refer to the Terminology (UMT/DCL/DD/0004 or
411-8111-804).
The specific acronyms used in this publication are the following:
A. Release
Available Release
CC
Cumulative Counter
CUM
CUMulative
DER
DTD
mW
milliWatt
NEI
NEIghboring
RSSI
SI
Status Inspection
VAL
VALue counter
Nortel Confidential
meaning as the word 'counter' and is used in this publication to distinguish a counter from a '(radio) measurement'.
Access Stratum Config- Pointer to a pre-defined set of Radio Bearers providing a given Rauration
dio Access Bearer service.
For example:
the DL access stratum configuration which number is 2 is dedicated to packet support at 64 Kbps; it comprises the following
Radio Bearers : 1 x 64 Kbps PS RB on DTCH and 3 x 3.4 Kbps
SRB for DCCH.
Refer to the following configurations:
Downlink Access Stratum Configuration (DASC)
Downlink Radio Bearer Set Configuration (DRBS)
Uplink Access Stratum Configuration
Reference cell
Nortel Confidential
Nortel Confidential
Nortel Confidential
Updated/Modified counters
The following counters have been modified:
#0536 VS.IuRelocationRequestFailuresCs.
#0805 (VS.PagingMessagesSentOnPcch)
Nortel Confidential
#0511 (VS.IuRelocationCancels.)
#0525 (VS.IuRelocationCommandFailuresCs.)
#0526 (VS.IuRelocationCommandFailuresPs.)
#0804 (VS.PagingRecordsSentOnPcch)
#0806 (VS.PagingUnscheduledRecords)
#0807 (VS.PagingCancelledRecords)
#0808 (VS.PagingRejectedRequests)
#0809 (VS.PagingDelayedRecords)
#0810 (VS.UnhandledPagingRequestsCs.)
#0811 (VS.UnhandledPagingRequestsPs.)
#0011 VS.RadioLinkEstablishedPerCell.NbEvt
#0011 VS.RadioLinkEstablishedPerCell.Avg
#0011 VS.RadioLinkEstablishedPerCell.Max
#0011 VS.RadioLinkEstablishedPerCell.Min
#0411 VS.RrcAvgActiveSetSize.Min
#0411 VS.RrcAvgActiveSetSize.Max
#0414 VS.RrcAvgNumCellFach.Avg
#0414 VS.RrcAvgNumCellFach.Min
#0414 VS.RrcAvgNumCellFach.Max
#0520 VS.IuAvgNbrSccpCnx.Max
#0520 VS.IuAvgNbrSccpCnx.Min
#0619 VS.RabAvgNbrEstablished.NbEvt
#0619 VS.RabAvgNbrEstablished.Avg
#0619 VS.RabAvgNbrEstablished.Min
#0619 VS.RabAvgNbrEstablished.Max
Nortel Confidential
#1002 VS.AvgTxPower.NbEvt
#1002 VS.AvgTxPower.Avg
#1002 VS.AvgTxPower.Max
#1002 VS.AvgTxPower.Min
#1315 VS.IurAvgNbrInitSccpCnx.Max
#1315 VS.IurAvgNbrInitSccpCnx.Min
#1316 VS.IurAvgNbrTermSccpCnx.Avg
#1316 VS.IurAvgNbrTermSccpCnx.Max
#1316 VS.IurAvgNbrTermSccpCnx.Min
#10303 VS.RachNack.NbEvt
#10303 VS.RachNack.Avg
#10303 VS.RachNack.Max
#10303 VS.RachNack.Min
Nortel Confidential
Nortel Confidential
10
Renamed counters
The counter "VS.ReceivedPagingRequestType1Idle.PflaPagingxxDomain" has been renamed as
#0801 VS.ReceivedPagingRequest. (Paging) .
Updated topics
The Access observation file structure figure has been updated.
The following tables have been updated:
RAB configurations
Added topics
The following sections have been added:
"Counter families"
"Wording assumption"
Radio counters
RACH Counters
Nortel Confidential
EEC counters
HSSPC counters
iBTS IP counters
Handover counters
Paging counters
11
Nortel Confidential
12
Nortel Confidential
13
"Counter families"
"Object hierarchy"
"Wording assumption"
"Counter hierarchy"
"Aggregation rules"
Counter families
The counters specified in this publication are grouped into families of counters. A family of counters
is attached to a given UMTS feature (for example, Hard hand-over where are put together counters
that allow to report hard hand-over performances) or to a performance management purpose (for
example, Traffic where are put together counters related to traffic observation). Each family of
counters is described in a separate section.
Object hierarchy
Counters are reported on objects (that is location) according to their hierarchy.
The following figures show the hierarchy of objects.
Nortel Confidential
14
Nortel Confidential
15
Nortel Confidential
16
GAUGE (dynamic variable), data being measured can vary during the period of
measurement.
DER (Discrete Event Registration), data related to a particular event is captured every nth
event, where n can be 1 or larger.
SI (Status Inspection), data related to the mean value is captured every nth sampling, where
n can be 1 or larger.
C-Condition
This section contains the condition that causes the measurement result data to be updated.
The condition is defined by identifying protocol related triggering events that either start or stop
the measurement processes or by updating the current measurement result value. When a
precise condition cannot be provided, the conditional circumstances behind the update are
stated.
D-Measurement result
This section contains a description of expected result value(s) (for example, a single integer
value). If more than one value is provided, the measurement is screened according to criteria, for
example, a number of call releases may be screened according to the cause of the call releases.
The number of call releases related to a given cause can be considered a subcounter. In that
case, the measurement result specification item includes a 'screening paragraph' that specifies
the various subcounters and their meanings.
For consistency purposes, 'Screening = NO' is the value given to counters that provide only one
result value.
E-Measurement type
This section contains a short form of the measurement name specified in the header, which is
used to identify the measurement type in the result files.
F-Measurement object instance
This section contains the object class and its instance. The "measObjInstId" field identifies the
measured object class and its instance; for example, trunk1 means that object class trunk
instance #1 is being measured. The object class and instance values used for this purpose will
be in accordance with 3GPP TS 32.106. This means the NE or resource object model (defined in
the Basic CM IRP Information Model - 3GPP TS 32.106-5) and naming conventions (defined in
the Naming Convention for Managed Objects - 3GPP TS 32.106-8). This parameter, if applicable,
will be provided in the measurement job.
G-Switching technology
This section contains the Switching domain(s). Its measurement is applicable to Circuit Switched
and, or Packet Switched domains.
Note: Two counter specification items have been added to the seven preceding 3GPP items
by Nortel.
H-3GPP compliance
Nortel Confidential
17
This section states the compliance of the Nortel Network measurement with 3GPP specifications:
the statement is "3GPP specified counter" if the NORTEL implementation is fully compliant
with the 3GPP specification.
the statement is "NORTEL specified counter" if the counter is not considered by the 3GPP
specification.
I-Available release
This section states the Nortel UMTS system release(s) in which the counter had been introduced.
Note: The "measurement" and "counter" wording have the same meaning.
Counter types on the OAM GUI
The three types of user-accessible observation counters available on the OAM GUI are as follows:
VALUE
LOAD
CUMULATIVE counters
CUMULATIVE counters provide raw counts. A CUMULATIVE counter is a CUM (CC) type
counter, as identified in 3GPP TS 32.104 specifications. It is incremented by 1 each time the
counted event occurs, and it provides the cumulated value. One NE cumulative counter provides
one counter at the OAM GUI level.
VALUE counters
VALUE counters are elaborated according to the mechanism defined by 3GPP TS 32.104, in
order to implement a DER (VAL) type measurement. This mechanism provides average values
from raw counts obtained by internal events (the time interval between two events is random and
is not accessible to users). The counter is incremented by a value attached to the event itself.
Nortel provides the following:
LOAD counters
LOAD counters are elaborated according to the mechanism defined by 3GPP TS 32.104, in order
to implement an SI type measurement. This mechanism provides average values from raw
counts obtained by internal sampling (the time interval between two events is constant and is not
accessible to users). The counter is incremented by a sampled value on the sampling event
occurrence. Nortel provides the following:
Nortel Confidential
18
Counter hierarchy
An observation counter stored in XML files can contain one or several levels.
A dot (.) separates two successive levels.
The following example shows the counter hierarchy with five levels.
Example:
radioLink.establishment.failure.cause<Name>.Avg
Counters with one level do not end with a dot.
Example:
droppedLastRadioLink
Aggregation rules
When aggregating counters from different periods of observation (temporal aggregation) you must
follow the following rules.
Let X1,X2,...,Xn the measurements from periods 1,2,...,n and X the resulting value over the total
period.
The following table presents a rule for each counter.
Table 1 Table of aggregation rules
Rule
Results
Apply to
Rtotal
Rload/Rval
Rload*
Same as Rload but resulting X.cum has no physi- Some LOAD counters
cal meaning due to the nature of the measurement (like percents) and is not interpreted but is
necessary for intermediate computations.
Ravg
X = Xi / n
Passport counters
Nortel Confidential
19
Rule
Results
Apply to
X = Xi
where Xi (i = 1 to n) represent cumulative values
Passport counters
Rmin
X = min (Xi)
where Xi (i = 1 to n) represent minimum values
Passport counters
Rmax
X = max (Xi)
where Xi (i = 1 to n) represent maximum values
Passport counters
Nortel Confidential
20
Nortel Confidential
21
Nortel Confidential
22
For more information about UTRAN objects and their relationships, refer to the About the Access
Network OAM (UMT/DCL/DD/0010 or 411-8111-510) publication.
Each record file contains the counters produced by a single NE collection.
Access Network observation counters handled by the ADI application for the UMTS04 system
release are as follows:
Node B counters
These counters have been divided into the three following sets of families:
Each counter family is attached to a given UMTS feature (for example, Handover counters, where
hard handover performances are reported) or to a Performance Management purpose for example,
User Plane Traffic counters, where counters related to traffic observation are grouped together).
Access observation file structure
Some observation counters are processed in order to provide temporal and spatial aggregations. The
following observation counter records are available:
single period
hourly aggregated
daily aggregated
Each observation file produces single, hourly and daily observation counter records. At the dedicated
NE level, a predetermined subset of these data are aggregated.
The following figure illustrates an example of the aggregated observation file structure.
Nortel Confidential
23
the observation file contains data originated from a single NE for a unique time period.
Nortel Confidential
24
the observation file contains data originated from a single NE for an hourly aggregated file.
the observation file contains data originated from a single NE for a daily aggregated file.
startdate is the beginning date of the granularity period; its format must be <YYYYMMDD>.
starttime is the beginning time of the granularity period; its format must be <hhmm+GMT>.
endtime is the end time of the granularity period; its format must be <hhmm+GMT>.
NE is the Network Element type ID that means a unique numerical identifier as 3GPP using
<NE Type>-<NE userlabel> _[CN|AN|IN] pattern (for example, RNC-RNC535_CN).Or the BTS
name using the NE userLabel as a NE ID (for example BTSEq-A10km215).
Refer to the following table for an interpretation of the codes:
Code
Description
YYYY
MM
The month of the year (01, 02,..., 12) for file creation time at RNC level
DD
The day of the month (01, 02,..., 31) for file creation time at RNC level
hh
The 2-digit hour (00, 01,..., 23). In the case of daily aggregation files, hh is always 00.
mm
The 2-digit minute of the hour. Possible values are by increments of five minutes: 00, 05, 10, 15, 20, 25, 30, 35, 40, 45, 50, and 55. In the case of hourly or
daily aggregation files, mm is always 00.
GMT
Nortel Confidential
25
For more information about Node B XML record files, refer to the Performance Management for
Access Network (UMT/DCL/DD/0021 or 411-8111-534) publication.
RNC observation XML file
The XML format is compliant with 3 GPP dtd file: 32.401-02.dtd. The granularity period defines, in
minutes, the periodicity of the generation of the counter; the values supported are 15, 30 and 60.
The directory of the RNC C-Node observation XML file on PerfServer is as follows:
/opt/nortel/data/access/observation/<YYYYMMDD>/<RNC><RNCUserLabel>_CN
Example:
/opt/nortel/data/observation/access/200400422/RNC-RNC535_CN/
The following figure illustrates an example of the RNC C-Node XML observation file.
Nortel Confidential
26
The directory of the RNC I-Node observation XML file on PerfServer is as follows:
/opt/nortel/data/access/observation/<YYYYMMDD>/<RNC><PPUserLabel>_IN
The following figure illustrates an example of the RNC I-Node XML observation file.
Nortel Confidential
27
The directory of the RNC A-Node observation XML file on PerfServer is as follows:
/opt/nortel/data/access/observation/<YYYYMMDD>/<RNC>-<PPUserLabel>_AN
The following figure illustrates an example of the RNC A-Node XML observation file.
Nortel Confidential
28
For more information about RNC XML record files, refer to the Performance Management for
Access Network (UMT/DCL/DD/0021 or 411-8111-534) publication.
RNC C-Node observation during OMU SWACT
The OMU SWACT (SWitch of ACTivity) is a mechanism allowing to switch over the active OMU. This
mechanism is specific to the RNC C-Node.
When an OMU SWACT occurs, counters do not appear in PrOptma application for the 15-minute
window, and the file transmitted from the new active OMU to the perfServer contains only a portion of
data.
Let the following example based on a 15-minute collect time, the last collect launched by OMU at
2:15 p.m., and notifiaction sent and received at 2:20 p.m. (that means the preceding collect is ended
and is correctly handled)
The impacts of the OMU SWACT are given in the following cases:
Case 1. If SWACT occurs at 2:21 p.m., thus after the last collect or notification, and the restart
Nortel Confidential
29
takes one minute, the TMUs remain running and computing statistics; at 2:30 p.m., the OMU will
send a collect request to all entities. Therefore there is no impact from OAM.
Case 2: If SWACT occurs at 2:29 p.m., and when the OMU becomes active again, for example at
2:32 p.m., it will be too late to send a collect request. Therefore the next collect time will be at
2.45pm and lasts 30 minutes. This is a restriction.
Case 3. If the collect request is sent at 2:30 p.m. but OMU SWACT occurs at 2:31 p.m. before
any end of computing or before all the TMUs have time to send to the OMU their collect, the file
will be closed, and remain on disk with only header, or part of the information or all of the
information if writing already started. The next period of collect will be aligned on the correct
15-minute period. Therefore there is no notification sent to the OAM, and the period of collect
from 2:25 to 2:30 p.m. is lost. The next collect will be on a valid period. This is a restriction.
Case 4. If the collect request is sent at 2:30 p.m. but not all the LAs have received the collect
request before SWACT occurs, that occurrence is quite rare, but remains possible. Therefore
there is no collect for 2:15 p.m. to 2:30 p.m. period, and a bad period of collect from 2:30 p.m. to
2:45 p.m. is recorded. This is a restriction.
Nortel Confidential
30
"Handover counters"
"Paging counters"
Nortel Confidential
31
Counter name
#0001
VS.RadioLinkSetupSuccess.
#0002
VS.RadioLinkSetupUnsuccess.
#0003
VS.RadioLinkAdditionSuccess.
#0004
VS.RadioLinkAdditionUnsuccess.
#0005
VS.RadioLinkDeletionSuccess
#0006
VS.RadioLinkDeletionUnsuccess
#0007
VS.RadioLinkReconfigurationPrepareSuccess.
#0008
VS.RadioLinkReconfigurationPrepareUnsuccess.
#0009
VS.RadioLinkReconfigurationCancelSuccess.
#0010
VS.RadioLinkReconfigurationCommitSuccess.
#0011
VS.RadioLinkEstablishedPerCell.Cum
VS.RadioLinkEstablishedPerCell.NbEvt
VS.RadioLinkEstablishedPerCell.Avg
VS.RadioLinkEstablishedPerCell.Max
VS.RadioLinkEstablishedPerCell.Min
#0013
VS.RadioLinkDroppedLastRadioLink.
#0016
VS.RlSleepyCellInactivity
This measurement provides the number of radio links successfully setup on an NBAP, which are screened by DL Access Stratum configuration.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Nortel Confidential
32
E-Type
VS.RadioLinkSetupSuccess.
F-Object Instance
(Location)
FDDCell/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of failed radio link setups on a NBAP protocol, screened by detecting event.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
On receipt of an RADIO LINK SETUP FAILURE NBAP message sent by Node B to the Controlling RNC, in response to
an RADIO LINK SETUP REQUEST
The measurement considers each radio link referred as
failed in the NBAP RADIO LINK SETUP FAILURE message.
D-Result
(Unit)
Nortel Confidential
33
Screening is as follows:
E-Type
VS.RadioLinkSetupUnsuccess.RadioLinkSetupFailure
VS.RadioLinkSetupUnsuccess.Timeout
VS.RadioLinkSetupUnsuccess.RrmRefusal
VS.RadioLinkSetupUnsuccess.INodeRefusal
VS.RadioLinkSetupUnsuccess.LackOfNodeBDlProcessingR
esources
VS.RadioLinkSetupUnsuccess.LackOfNodeBUlProcessingR
esources
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V4
This measurement provides the number of radio links successfully added on an NBAP protocol, which are screened by Downlink Access Stratum configuration.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Nortel Confidential
34
E-Type
VS.RadioLinkAdditionSuccess.
F-Object Instance
(Location)
FDDCell/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of radio links failed in addition to an NBAP protocol, which are screened by a detecting
event.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
On time-out expired without receiving an RADIO LINK ADDITION RESPONSE message or an RADIO LINK ADDITION
FAILURE message
The measurement considers each Radio Link required to addition in the NBAP RADIO LINK ADDITION REQUEST message.
D-Result
(Unit)
Nortel Confidential
E-Type
35
VS.RadioLinkAdditionUnsuccess.RadioLinkAdditionFailure
VS.RadioLinkAdditionUnsuccess.Timeout
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of radio links successfully deleted on an NBAP protocol.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioLinkDeletionSuccess
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CUM (CC)
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
36
E-Type
VS.RadioLinkDeletionUnsuccess
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of successful synchronized NBAP RADIO LINK RECONFIGURATION PREPARATION messages, which are screened by DL Access Stratum
configuration.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioLinkReconfigurationPrepareSuccess.
F-Object Instance
(Location)
FDDCell / DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CUM (CC)
C-Condition
Nortel Confidential
(Event)
D-Result
(Unit)
E-Type
37
VS.RadioLinkReconfigurationPrepareUnsuccess.RadioLinkR
econfigurationFailure
VS.RadioLinkReconfigPrepareUnsuccess.TimeoutNBAP
VS.RadioLinkReconfigPrepareUnsuccess.RrmRefusal
VS.RadioLinkReconfigPrepareUnsuccess.INodeRefusal
VS.RadioLinkReconfigPrepareUnsuccess.LackOfNodeBDlPr
ocessingResources
VS.RadioLinkReconfigPrepareUnsuccess.LackOfNodeBUlPr
ocessingResources
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V4
Nortel Confidential
38
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioLinkReconfigurationCancelSuccess.
F-Object Instance
(Location)
FDDCell / DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
39
E-Type
VS.RadioLinkReconfigurationCommitSuccess.
F-Object Instance
(Location)
FDDCell / DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
SI
NORTEL LOAD type counter
("Cumulating value" part)
C-Condition
(Event)
On each setup success, delete success, delete unsuccess, addition success on an radio link of the cell (counted per radio link
and not per message)
The number of radio links is sampled each 100ms.
D-Result
(Unit)
E-Type
VS.RadioLinkEstablishedPerCell.Cum
F-Object Instance
(Location)
FDDCell/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement indicates the number of NBAP radio-links established in a cell during a reporting period.
B-Collection
SI
NORTEL LOAD type counter ("Number of events" part)
C-Condition
Nortel Confidential
40
(Event)
D-Result
(Unit)
A single integer value (NbEvt = 1) is expressed for each DL Access Stratum configuration.
Screening is as follows:
E-Type
VS.RadioLinkEstablishedPerCell.NbEvt
F-Object Instance
(Location)
FDDCell/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement indicates the average number of NBAP radiolinks established in a cell during a reporting period.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
On each setup success, delete success, delete unsuccess, addition success on a radio-link of the cell (counted per radio-link and
not per message)
The number of radio-links is sampled each 100ms.
D-Result
(Unit)
E-Type
VS.RadioLinkEstablishedPerCell.Avg
F-Object Instance
(Location)
FDDCell/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
41
This measurement indicates the maximum number of NBAP radio-links established in a cell during a reporting period.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
On each setup success, delete success, delete unsuccess, addition success on a radio-link of the cell (counted per radio-link and
not per message)
The number of radio-links is sampled each 100ms.
D-Result
(Unit)
E-Type
VS.RadioLinkEstablishedPerCell.Max
F-Object Instance
(Location)
FDDCell/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement indicates the minimum number of NBAP radio-links established in a cell during a reporting period.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
On each setup success, delete success, delete unsuccess, addition success on a radio-link of the cell (counted per radio-link and
not per message)
The number of radio-links is sampled each 100ms.
D-Result
(Unit)
Nortel Confidential
42
E-Type
VS.RadioLinkEstablishedPerCell.Min
F-Object Instance
(Location)
FDDCell/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioLinkDroppedLastRadioLink.
F-Object Instance
(Location)
FDDCell/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V2 (modified in V4)
B-Collection
CC
NORTEL CUM type counter
Nortel Confidential
43
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RlSleepyCellInactivity
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V4
Nortel Confidential
44
Handover counters
This section describes all the handover observation counters for RAN V4.0 of the UMTS V4.0 system
release.
The handover counters report the number of events attached to hard handovers.
The following table lists all the Hard Handover counters.
Table 20 Hard Handover counters
Nortel counter number
Counter name
#0101
VS.RrcHoFromUtranCommand.
#0102
VS.RrcHoFromUtranCommandNeighbRnc.
#0103
VS.RrcHoFromUtranFailure
#0104
VS.RrcHoFromUtranFailureNeighbRnc.
#0105
IRATHO.AttOutPSUTRAN
#0106
VS.RrcCellChangeOrderNeighbRnc
#0107
IRATHO.FailOutPS
#0108
VS.RrcCellChangeOrderFailureNeighbRnc.
#0109
VS.3gTo2gHoDetectionFromFddcell.
#0110
VS.3gTo2gHoDetectionFromFddcellNeighbRnc.
#0111
VS.IntraRncOutgoingBlindHoAttempt.
#0112
VS.IntraRncOutgoingBlindHoFailure.
#0113
VS.IntraRncIncomingHoAttempt.
#0114
VS.IntraRncIncomingHoFailure.
#0119
VS.InterPlmnOutgoingHardHoAttempt.
#0120
VS.InterPlmnOutgoingHardHoFailure.
#0121
VS.InterPlmnOutgoingHardHoSuccess
#0122
VS.WithoutIurIncomingHardHoAttempt.
#0123
VS.WithoutIurIncomingHardHoFailure.
#0124
VS.WithoutIurIncomingHardHoSuccess.
#0125
VS.InterRncWithoutIurIncomingHardHoAttempt.
#0126
VS.InterRncWithoutIurIncomingHardHoFailure.
#0127
VS.InterRncWithoutIurIncomingHardHoSuccess.
Nortel Confidential
B-Collection
C-Condition
(Event)
D-Result
(Unit)
45
E-Type
VS.RrcHoFromUtranCommand.RescueCS
VS.RrcHoFromUtranCommand.ServiceCS
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RrcHoFromUtranCommandNeighbRnc.RescueCS
Nortel Confidential
F-Object Instance
(Location)
46
VS.RrcHoFromUtranCommandNeighbRnc.ServiceCS
Neighboring RNC
G-Switching
H-3GPP Compliance
I-Available Release
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RrcHoFromUtranFailure.RescueCS
VS.RrcHoFromUtranFailure.ServiceCS
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
B-Collection
C-Condition
(Event)
D-Result
(Unit)
E-Type
F-Object Instance
(Location)
47
boring RNC.
Neighboring RNCs act as Drift RNCs controlling the reference cell
of the involved UEs, that means an involved UE in the procedure
is served by an RNC that is not controlling its own reference cell.
CC
NORTEL CUM type counter
On emission of an RRC HANDOVER FROM UTRAN FAILURE
message by an RRC from a UE, having its reference cell controlled by another RNC
A single integer value per reason
However, only Rescue 3G to 2G HO for CS is supported.
Screening is as follows:
VS.RrcHoFromUtranFailureNeighbRnc.RescueCS
VS.RrcHoFromUtranFailureNeighbRnc.ServiceCS
Neighboring RNC
G-Switching
H-3GPP Compliance
I-Available Release
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
IRATHO.AttOutPSUTRAN
F-Object Instance
Nortel Confidential
48
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
C-Condition
(Event)
D-Result
(Unit)
E-Type
F-Object Instance
(Location)
Neighboring RNC
G-Switching
H-3GPP Compliance
I-Available Release
B-Collection
Nortel Confidential
C-Condition
(Event)
D-Result
(Unit)
E-Type
49
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RrcCellChangeOrderFailureNeighbRnc.RescuePS
Neighboring RNC
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
Nortel Confidential
I-Available Release
50
NORTEL # 0108
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition (Event)
D-Result
(Unit)
E-Type
VS.3gTo2gHoDetectionFromFddcell.RescueCS
VS.3gTo2gHoDetectionFromFddcell.RescuePS
VS.3gTo2gHoDetectionFromFddcell.ServiceCS
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
Nortel Confidential
51
(Event)
D-Result
(Unit)
E-Type
VS.3gTo2gHoDetectionFromFddcellNeighbRnc.RescueCS
VS.3gTo2gHoDetectionFromFddcellNeighbRnc.RescuePS
VS.3gTo2gHoDetectionFromFddcellNeighbRnc.ServiceCS
F-Object Instance
(Location)
Neighboring RNC
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IntraRncOutgoingBlindHoAttempt.Capacity
VS.IntraRncOutgoingBlindHoAttempt.Mobility
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
Nortel Confidential
I-Available Release
52
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IntraRncOutgoingBlindHoFailure.FailureDueToNotEnough
Resources
VS.IntraRncOutgoingBlindHoFailure.NodeBFailure
VS.IntraRncOutgoingBlindHoFailure.FailureOnRrc
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
On emission of a NBAP RADIO_LINK_SETUP_REQUEST message for this cell for a call supported by another cell with a different frequency in the same RNC
D-Result
Nortel Confidential
(Unit)
E-Type
53
Screening is as follows:
VS.IntraRncIncomingBlindHoAttempt.Capacity
VS.IntraRncIncomingBlindHoAttempt.Mobility
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of failed Intra RNC incoming Hard Handovers from another cell using another frequency in the same RNC to this cell (only Blind HO in V3).
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IntraRncIncomingBlindHoFailure.FailureDueToNotEnough
Resources
VS.IntraRncIncomingBlindHoFailure.NodeBFailure
VS.IntraRncIncomingBlindHoFailure.FailureOnRrc
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
54
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.WithoutIurIncomingHardHoAttempt.TimeCriticalRelocatio
n
VS.WithoutIurIncomingHardHoAttempt.RelocationDesireable
ForRadioReasons
VS.WithoutIurIncomingHardHoAttempt.DirectedRetry
VS.WithoutIurIncomingHardHoAttempt.UnexpectedCause
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
Nortel Confidential
(Unit)
E-Type
55
Screening is as follows:
VS.WithoutIurIncomingHardHoFailure.FailureInRelocationPro
cedures
VS.WithoutIurIncomingHardHoFailure.FailureInSecurityProce
dures
VS.WithoutIurIncomingHardHoFailure.FailureInRncProcedure
s
VS.WithoutIurIncomingHardHoFailure.UnexpectedCause
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.WithoutIurIncomingHardHoSuccess.TimeCriticalRelocatio
n
VS.WithoutIurIncomingHardHoSuccess.RelocationDesireable
ForRadioReasons
Nortel Confidential
56
VS.WithoutIurIncomingHardHoSuccess.DirectedRetry
VS.WithoutIurIncomingHardHoSuccess.UnexpectedCause
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.InterPlmnOutgoingHardHoAttempt.TimeCriticalRelocation
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Reception of an RANAP RELOCATION PREPARATION FAILURE or RANAP RELOCATION CANCEL or IU RELEASE COMMAND (cause relocation cancel) or RRC HO FAILURE or timeout (in case of 3G to 3G relocation with target cell PLMN different
from source cell PLMN)
Nortel Confidential
D-Result
(Unit)
E-Type
57
Subcounter #1 => relocation cancelled, normal release, release due to UTRAN generated reason
VS.InterPlmnOutgoingHardHoFailure.FailureInRelocationPro
cedures0
VS.InterPlmnOutgoingHardHoFailure.FailureInRelocationPro
cedures1
VS.InterPlmnOutgoingHardHoFailure.FailureInRncProcedure
s
VS.InterPlmnOutgoingHardHoFailure.FailureInRadioProcedur
es
VS.InterPlmnOutgoingHardHoFailure.UnexpectedCase
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Reception of RANAP IU RELEASE COMMAND (cause Relocation Successful) (in case of 3G to 3G relocation with target cell
PLMN different from source cell PLMN)
D-Result
(Unit)
Screening = NO
E-Type
VS.InterPlmnOutgoingHardHoSuccess
F-Object Instance
(Location)
G-Switching
Nortel Confidential
58
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.InterRncWithoutIurIncomingHardHoAttempt.TimeCriticalR
elocation
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
59
RNC or on time-out
E-Type
Subcounter #1 => relocation cancelled, normal release, release due to UTRAN generated reason
VS.InterRncWithoutIurIncomingHardHoFailure.FailureInReloc
ationProcedures0
VS.InterRncWithoutIurIncomingHardHoFailure.FailureInReloc
ationProcedures1
VS.InterRncWithoutIurIncomingHardHoFailure.FailureInRncP
rocedures
VS.InterRncWithoutIurIncomingHardHoFailure.FailureInRadio
Procedures
VS.InterRncWithoutIurIncomingHardHoFailure.UnexpectedC
ase
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
F-Object Instance
(Location)
VS.InterRncWithoutIurIncomingHardHoSuccess.TimeCritical
Relocation
Nortel Confidential
60
G-Switching
H-3GPP Compliance
I-Available Release
V3
Counter name
3GPP counter
SHO.AttRLAddUTRANSide
3GPP counter
SHO.FailRLAddUTRANSide.
3GPP counter
SHO.SuccRLAddUTRANSide
3GPP counter
SHO.SucRLDelUTRANSide
3GPP counter
SHO.SuccRLAddUESid
3GPP counter
SHO.SuccRLDelUESid
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
SHO.AttRLAddUTRANSide
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
3GPP counter
This measurement is not provided by the RNC but is computed
by the OAM using the following
formula:VS.RadioLinkSetupSuccess (all Downlink Access Stratum Configurations consolidated) +
VS.RadioLinkSetupUnsuccess (all causes consolidated) +
VS.RadioLinkAdditionSuccess (all Downlink Access Stratum
Configurations consolidated) + VS.RadioLinkAdditionUnsuccess
(all causes consolidated).
Nortel Confidential
61
V3
This measurement provides the number of failed radio link creations (UTRAN side) for each cell. This measurement is increased for each failed radio link setup or radio link addition
(Softer HO) (UTRAN side).
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
SHO.FailRLAddUTRANSide.Failure
SHO.FailRLSucUTRANSide.Timeout
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
3GPP counter
This measurement is not provided by the RNC but is computed
by the OAM using the following formula:
VS.RadioLinkSetupFailure.Cause +
VS.RadioLinkAdditionFailure.Cause.
Note: This counter is compliant with 3GPP TS32.104
Rel99 definition.
I-Available Release
V4
Nortel Confidential
62
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
SHO.SuccRLAddUTRANSide
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
3GPP counter
This measurement is not provided by the RNC but is computed
by the OAM using the following
formula:VS.RadioLinkSetupSuccess (all Downlink Access Stratum Configurations consolidated) +
VS.RadioLinkAdditionSuccess (all Downlink Access Stratum
Configurations consolidated) .
Note: This counter is compliant with 3GPP TS32.104
Rel99 definition.
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
SHO.SuccRLDelUTRANSide
Nortel Confidential
63
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
3GPP counter
This measurement is not provided by the RNC but is computed
by the OAM using the
VS.RadioLinkDeletionSuccess formula.
I-Available Release
V3
This measurement provides the number of successful RRC ACTIVE SET UPDATE procedures managed by an RNC.
During the RRC Active Set Update procedure, this measurement is incremented by the number of cells added to the active
set.
This measurement increments for the cells that were in the original active set.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
On receipt of an RRC ACTIVE SET UPDATE COMPLETE message sent by the UE to the Serving RNC in response to an ACTIVE SET UPDATE message
D-Result
(Unit)
E-Type
SuccRLAddUESide
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of successful RRC ACTIVE SET UPDATE procedures managed by an RNC.
During the RRC Active Set Update procedure, this measurement is incremented by the number of cells removed from the
active set.
This measurement increments for the cells that were in the original active set.
B-Collection
CC
Nortel Confidential
64
On receipt of an RRC ACTIVE SET UPDATE COMPLETE message sent by the UE to the Serving RNC in response to an ACTIVE SET UPDATE message
D-Result
(Unit)
E-Type
SHO.SuccRLDelUESide
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
65
Counter name
#0301
VS.AveragePowerUsedForSpeech.Cum
VS.AveragePowerUsedForSpeech.NbEvt
VS.AveragePowerUsedForSpeech.Avg
VS.AveragePowerUsedForSpeech.Min
VS.AveragePowerUsedForSpeech.Max
#0302
VS.AveragePowerUsedForData.Cum
VS.AveragePowerUsedForData.NbEvt
VS.AveragePowerUsedForData.Avg
VS.AveragePowerUsedForData.Min
VS.AveragePowerUsedForData.Max
#0303
VS.UplinkRSSI.Cum
VS.UplinkRSSI.NbEvt
VS.UplinkRSSI.Avg
VS.UplinkRSSI.Min
VS.UplinkRSSI.Max
#0304
VS.AveragePowerUsedForSignalling.Cum
VS.AveragePowerUsedForSignalling.NbEvt
VS.AveragePowerUsedForSignalling.Avg
VS.AveragePowerUsedForSignalling.Min
VS.AveragePowerUsedForSignalling.Max
#0305
VS.AveragePowerUsedForMiscellaneous.Avg
VS.AveragePowerUsedForMiscellaneous.Min
VS.AveragePowerUsedForMiscellaneous.Max
B-Collection
DER
NORTEL VAL type counter ("Cumulating value" part)
C-Condition
(Event)
The cell power used for speech calls is updated on each addition or deletion of a radio-link supporting a speech call.
Nortel Confidential
66
D-Result
(Unit)
E-Type
VS.AveragePowerUsedForSpeech.Cum
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V1
B-Collection
DER
NORTEL VAL type counter ("Number of events" part)
C-Condition
(Event)
The cell power used for speech calls is updated on each addition or deletion of a radio-link supporting a speech call.
D-Result
(Unit)
E-Type
VS.AveragePowerUsedForSpeech.NbEvt
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V1
B-Collection
DER
NORTEL VAL type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AveragePowerUsedForSpeech.Avg
Nortel Confidential
67
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V1
B-Collection
DER
NORTEL VAL type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AveragePowerUsedForSpeech.Min
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V1
B-Collection
DER
NORTEL VAL type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AveragePowerUsedForSpeech.Max
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
Nortel Confidential
68
H-3GPP Compliance
I-Available Release
V1
This measurement provides the cell power used for data calls
during a reporting period.
B-Collection
DER
NORTEL VAL type counter ("Cumulating value" part)
C-Condition
(Event)
The cell power used for data calls is updated on each addition or
deletion of a radio-link supporting a data call.
D-Result
(Unit)
E-Type
VS.AveragePowerUsedForData.Cum
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V1
B-Collection
DER
NORTEL VAL type counter ("Number of events" part)
C-Condition
(Event)
The average cell power used for data calls is updated on each
addition or deletion of a radio-link supporting a data call.
D-Result
(Unit)
E-Type
VS.AveragePowerUsedForData.NbEvt
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V1
Nortel Confidential
69
B-Collection
DER
NORTEL VAL type counter
C-Condition
(Event)
The average cell power used for data calls is updated on each
addition or deletion of a radio-link supporting a data call.
D-Result
(Unit)
E-Type
VS.AveragePowerUsedForData.Avg
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V1
B-Collection
DER
NORTEL VAL type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AveragePowerUsedForData.Min
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V1
Nortel Confidential
70
DER
NORTEL VAL type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AveragePowerUsedForData.Max
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V1
This measurement provides the uplink RSSI per cell during a reporting period.
B-Collection
DER
NORTEL VAL type counter ("Cumulating value" part)
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.UplinkRSSI.Cum
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V2
B-Collection
DER
NORTEL VAL type counter ("Number of events" part)
C-Condition
Nortel Confidential
71
(Event)
measurement message.
D-Result
(Unit)
E-Type
VS.UplinkRSSI.NbEvt
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V2
B-Collection
DER
NORTEL VAL type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.UplinkRSSI.Avg
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V2
B-Collection
DER
NORTEL VAL type counter
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
72
E-Type
VS.UplinkRSSI.Min
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V2
B-Collection
DER
NORTEL VAL type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.UplinkRSSI.Max
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V2
B-Collection
DER
NORTEL VAL type counter ("Cumulating value" part)
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AveragePowerUsedForSignalling.Cum
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
Nortel Confidential
73
H-3GPP Compliance
I-Available Release
V2
B-Collection
DER
NORTEL VAL type counter ("Number of events" part)
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AveragePowerUsedForSignalling.NbEvt
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V2
This measurement provides the average cell power used for signaling during a reporting period.
B-Collection
DER
NORTEL VAL type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AveragePowerUsedForSignalling.Avg
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
74
B-Collection
DER
NORTEL VAL type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AveragePowerUsedForSignalling.Min
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V2
B-Collection
DER
NORTEL VAL type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AveragePowerUsedForSignalling.Max
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
75
DER
NORTEL VAL type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AveragePowerUsedForMiscellaneous.Avg
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V3
B-Collection
DER
NORTEL VAL type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AveragePowerUsedForMiscellaneous.Min
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V3
B-Collection
DER
NORTEL VAL type counter
Nortel Confidential
76
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AveragePowerUsedForMiscellaneous.Max
F-Object Instance
(Location)
FDDCell
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
77
Counter name
#0014
VS.NumberUeWithNRadioLinks.<Nb Rl>.Avg
VS.NumberUeWithNRadioLinks.<Nb Rl>.Max
VS.NumberUeWithNRadioLinks.<Nb Rl>.Min
#0402
VS.RrcActiveSetUpdateUnsuccess.
#0406
VS.RrcActiveSetUpdateSuccessNeighbRnc.
#0407
VS.RrcActiveSetUpdateUnsuccessNeighbRnc.
#0411
VS.RrcAvgActiveSetSize.Avg
VS.RrcAvgActiveSetSize.Min
VS.RrcAvgActiveSetSize.Max
#0412
VS.RrcTransitionCellFachToCellDch.
#0413
VS.RrcTransitionCellDchToCellFach
#0414
VS.RrcAvgNumCellFach.Avg
VS.RrcAvgNumCellFach.Min
VS.RrcAvgNumCellFach.Max
#0415
VS.RrcActiveSetUpdateCompleteProcedure
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
On reception of a NBAP RL Setup Response, RL Addition Response, RL Addition Failure (in case some RLs are succesfully
added), RL Deletion Request and if the primary cell changes.
D-Result
(Unit)
E-Type
VS.NumberUeWithNRadioLinks.1RadioLinks.Avg
VS.NumberUeWithNRadioLinks.2RadioLinks.Avg
VS.NumberUeWithNRadioLinks.3RadioLinks.Avg
VS.NumberUeWithNRadioLinks.4RadioLinks.Avg
VS.NumberUeWithNRadioLinks.5RadioLinks.Avg
Nortel Confidential
78
VS.NumberUeWithNRadioLinks.6orMoreRadioLinks.Avg
F-Object Instance
(Location)
FDDCell (Reference)
G-Switching
H-3GPP Compliance
I-Available Release
V4
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
On reception of a NBAP RL Setup Response, RL Addition Response, RL Addition Failure (in case some RLs are succesfully
added), RL Deletion Request and if the primary cell changes.
D-Result
(Unit)
E-Type
VS.NumberUeWithNRadioLinks.1RadioLinks.Max
VS.NumberUeWithNRadioLinks.2RadioLinks.Max
VS.NumberUeWithNRadioLinks.3RadioLinks.Max
VS.NumberUeWithNRadioLinks.4RadioLinks.Max
VS.NumberUeWithNRadioLinks.5RadioLinks.Max
VS.NumberUeWithNRadioLinks.6orMoreRadioLinks.Max
F-Object Instance
(Location)
FDDCell (Reference)
G-Switching
H-3GPP Compliance
I-Available Release
V4
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
On reception of a NBAP RL Setup Response, RL Addition Response, RL Addition Failure (in case some RLs are succesfully
Nortel Confidential
79
E-Type
VS.NumberUeWithNRadioLinks.1RadioLinks.Min
VS.NumberUeWithNRadioLinks.2RadioLinks.Min
VS.NumberUeWithNRadioLinks.3RadioLinks.Min
VS.NumberUeWithNRadioLinks.4RadioLinks.Min
VS.NumberUeWithNRadioLinks.5RadioLinks.Min
VS.NumberUeWithNRadioLinks.6orMoreRadioLinks.Min
F-Object Instance
(Location)
FDDCell (Reference)
G-Switching
H-3GPP Compliance
I-Available Release
V4
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Time-out expired without receipt of an ACTIVE SET UPDATE COMPLETE message or a ACTIVE SET UPDATE
FAILURE message
The events are considered only for cells belonging to the active
set which are under the control of the RNC in charge of the measurement.
D-Result
(Unit)
E-Type
VS.RrcActiveSetUpdateUnsuccess.RrcActiveSetUpdateFailu
Nortel Confidential
80
re
VS.RrcActiveSetUpdateUnsuccess.Timeout
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of successful RRC ACTIVE SET UPDATE procedures managed by an RNC for each
neighboring RNC.
The counter is incremented as many times as there are cells in
a given neighboring RNC that are added/removed to/from active
set
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
On receipt of an RRC ACTIVE SET UPDATE COMPLETE message sent by the UE to the Serving RNC, in response to an ACTIVE SET UPDATE message
D-Result
(Unit)
E-Type
VS.RrcActiveSetUpdateSuccessNeighbRnc.radiolinkAdditio
nOnCell
VS.RrcActiveSetUpdateSuccessNeighbRnc.radiolinkRemov
alOnCell
F-Object Instance
(Location)
Neighboring RNC
G-Switching
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
81
CC
NORTEL CUM type counter
C-Condition
(Event)
E-Type
VS.RrcActiveSetUpdateUnsuccessNeighbRnc.RrcActiveSet
UpdateFailure
VS.RrcActiveSetUpdateUnsuccessNeighbRnc.Timeout
F-Object Instance
(Location)
Neighboring RNC
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
DER
NORTEL VAL type counter
C-Condition
(Event)
Nortel Confidential
D-Result
(Unit)
82
E-Type
VS.RrcAvgActiveSetSize.DLaccessStratumConf#ii.Avg
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
DER
NORTEL VAL type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RrcAvgActiveSetSize.DLaccessStratumConf#i.Min
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
83
B-Collection
DER
NORTEL VAL type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RrcAvgActiveSetSize.DLaccessStratumConf#i.Max
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RrcTransitionCellFachToCellDch.CallEstablishment
VS.RrcTransitionCellFachToCellDch.AlwaysOnUpgrade
Nortel Confidential
84
VS.RrcTransitionCellFachToCellDch.Multiservice
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RrcTransitionCellDchToCellFach
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
The measurement is updated on each event making a RRC context to enter or to leave Cell Fach state. This measurement is
sampled each 100ms.
D-Result
(Unit)
E-Type
VS.RrcAvgNbrCellFach.Avg
F-Object Instance
FDDCell
Nortel Confidential
85
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
The measurement is updated on each event making a RRC context to enter or to leave Cell Fach state. This measurement is
sampled each 100ms.
D-Result
(Unit)
E-Type
VS.RrcAvgNbrCellFach.Min
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
The measurement is updated on each event making a RRC context to enter or to leave Cell Fach state. This measurement is
sampled each 100ms.
D-Result
(Unit)
E-Type
VS.RrcAvgNbrCellFach.Max
F-Object Instance
(Location)
FDDCell
G-Switching
Nortel Confidential
86
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of successful RRC Active Set Update procedures, for which the cell is in the list of the
active set before or after the Active Set Update execution (even
if it is added or removed due to this procedure).
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RrcActiveSetUpdateCompleteProcedure
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
87
Counter name
#0015
VS.RrcSleepyCellInactivity
#0403
3GPP
RRC.SuccConnEstab.
#0404
3GPP
RRC.FailConnEstab.
#0405
VS.RrcConnectionRelease.
#0408
VS.RrcConnectionReleaseNeighbRnc
#0409
3GPP
RRC.AttConnEstab.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RrcSleepyCellInactivity
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V4
Nortel Confidential
88
This measurement provides the number of successful RRC connection establishments, which are screened by establishment
cause.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
On receipt of an RRC CONNECTION SETUP COMPLETE message by the RNC following an RRC connection establishment
attempt
An RRC connection establishment attempt is considered upon
receipt by the RNC of an RRC CONNECTION REQUEST message.
D-Result
(Unit)
E-Type
RRC.SuccConnEstab.#i
for #i from 0 to 20. Refer to RRC connection establishment
causes.
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of RRC connection establishment failures, which are screened by establishment failure cause.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
The measurement counts the number of RRC connection establishment attempts which have not evolved into an RRC connection establishment.
An RRC connection establishment attempt is considered upon
receipt by the RNC of an RRC CONNECTION REQUEST message.
An RRC connection establishment is considered upon receipt
by the RNC of an RRC CONNECTION SETUP COMPLETE
message following an RRC connection attempt.
Nortel Confidential
D-Result
(Unit)
89
E-Type
RRC.FailConnEstab."i"
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V2
Note: screening #7 is added in V3
This measurement provides the number of RRC connection releases managed by a RNC, which are screened by error cause,
for each cell controlled by the RNC.
During such a procedure, the measurement attached to a given
cell is incremented if the cell is the reference cell of the involved
UE.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
On emission by the RNC of the first RRC CONNECTION RELEASE message of an RRC Connection release procedure
(meaning that eventual repetitions are not taken into account)
The event is considered only when the UE has a reference cell
under the control of the RNC in charge of the measurement.
D-Result
(Unit)
Nortel Confidential
90
VS.RrcConnectionRelease.#i
for #i from 0 to 7. Refer to RRC connection release causes.
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of RRC connection releases managed by a RNC, which are screened by release
cause, for each neighboring RNC.
During such a procedure, the measurement attached to a given
neighboring RNC is incremented if the neighboring RNC controls the reference cell of the involved UE
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RrcConnectionReleaseNeighbRnc.#i
for #i from 0 to 7. Refer to RRC connection release causes.
F-Object Instance
(Location)
NeighbouringRNC
G-Switching
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
91
A-Description
This measurement provides the number of RRC connection requests, screened by establishment cause.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
RRC.AttConnEstab.#i
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
92
Counter name
#0501
VS.IuSccpCnxSuccess.
#0502
VS.IuSccpCnxUnsuccess.
#0503
VS.IuReleaseRequestCs
#0504
VS.IuReleaseRequestPs
#0505
VS.IuReleaseCommandCs.
#0506
VS.IuReleaseCommandPs.
#0511
VS.IuRelocationCancels.
#0512
VS.IuRelocationCompletes.
#0513
VS.IuRelocationDetects.
#0516
VS.IuReceivedSccpAbnormalDisconnectsCs
#0517
VS.IuEmittedSccpAbnormalDisconnectsPs.
#0518
VS.IuReceivedSccpAbnormalDisconnectsPs
#0520
VS.IuAvgNbrSccpCnx.Avg
VS.IuAvgNbrSccpCnx.Max
VS.IuAvgNbrSccpCnx.Min
#0521
VS.IuRelocationRequired.
#0524
VS.IuRelocationCommands.
#0525
VS.IuRelocationCommandFailuresCs.
#0526
VS.IuRelocationCommandFailuresPs.
#0527
VS.IuCsTimingAdjustmentRequests.
#0528
VS.IuCsTimingAdjustmentAcks.
#0529
VS.IuCsTimingAdjustmentNacks.
#0530
VS.IuCsTimingAdjustmentUnsupported.
#0531
VS.IuCsTimingAdjustmentTimeouts.
#0532
VS.IuEmittedSccpAbnormalDisconnectsCs.
#0533
VS.IuAbnormalReleaseRequestCs
#0534
VS.IuAbnormalReleaseRequestPs
#0535
VS.IuRelocationRequests.
#0536
VS.IuRelocationRequestFailuresCs.
Nortel Confidential
93
Counter name
VS.IuRelocationRequestFailuresPs.
This measurement provides the number of successful SCCP connections at the Iu interface, screened by the CN domain.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IuSccpCnxSuccess.WithCoreNetworkCS
VS.IuSccpCnxSuccess.WithCoreNetworkPS
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of failed SCCP connections at the Iu interface, screened by the CN domain with the
peer entity having refused the connection.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
E-Type
94
VS.IuSccpCnxUnsuccess.FaillucsConnectionReqByRnc
VS.IuSccpCnxUnsuccess.FaillucsConnectionReqByCs
VS.IuSccpCnxUnsuccess.FaillupsConnectionReqByRnc
VS.IuSccpCnxUnsuccess.FaillupsConnectionReqByPs
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IuReleaseRequestCs
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
Nortel Confidential
95
D-Result
(Unit)
Screening is as follows:
E-Type
VS.IuReleaseRequestPs
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
E-Type
96
VS.IuReleaseCommandCs.Normal
VS.IuReleaseCommandCs.SuccesfulRelocation
VS.IuReleaseCommandCs.PreviousrquestFromIrnc
VS.IuReleaseCommandCs.Other
VS.IuReleaseCommandCs.RelocationCancelled
VS.IuReleaseCommandCs.OamIntervention
VS.IuReleaseCommandCs.UnspecifiedFailure
VS.IuReleaseCommandCs.UserInactivity
VS.IuReleaseCommandCs.NoRemainingRab
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2 (modified in V4)
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
E-Type
97
VS.IuReleaseCommandPs.Normal
VS.IuReleaseCommandPs.SuccesfulRelocation
VS.IuReleaseCommandPs.PreviousrquestFromIrnc
VS.IuReleaseCommandPs.Other
VS.IuReleaseCommandPs.RelocationCancelled
VS.IuReleaseCommandPs.OamIntervention
VS.IuReleaseCommandPs.UnspecifiedFailure
VS.IuReleaseCommandPs.UserInactivity
VS.IuReleaseCommandPs.NoRemainingRab
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2 (modified in V4)
B-Collection
This measurement provides the number of RANAP RELOCATION_ CANCEL messages sent by the source RNC on Iu interface.
Relocation Cancel procedure can be initiated by the source RNC:
after the end of relocation procedure when the UE has returned to the source RNC by transmitting an RRC message
which indicates that the UE considers the source RNC as its
serving RNC; in other words, there was an hand-over failure
on target, and the UE has come back.
CC
NORTEL CUM type counter
Nortel Confidential
98
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IuRelocationCancels.WithCoreNetworkCS
VS.IuRelocationCancels.WithCoreNetworkPS
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of RANAP RELOCATION_ COMPLETE messages sent by the target RNC on Iu interface.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IuRelocationCompletes.WithCoreNetworkCS
VS.IuRelocationCompletes.WithCoreNetworkPS
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
99
This measurement provides the number of RANAP RELOCATION_ DETECT messages sent by the target RNC on Iu interface.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IuRelocationDetects.WithCoreNetworkCS
VS.IuRelocationDetects.WithCoreNetworkPS
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of received SCCP abnormal disconnections on Iu CS.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IuReceivedSccpAbnormalDisconnectsCs
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
100
This measurement provides the number of emitted SCCP abnormal disconnections on Iu PS.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IuEmittedSccpAbnormalDisconnectsPs.EndUserOriginate
d
VS.IuEmittedSccpAbnormalDisconnectsPs.EndUserFailure
VS.IuEmittedSccpAbnormalDisconnectsPs.EndUserCongesti
on
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of received SCCP abnormal disconnections on Iu PS.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IuReceivedSccpAbnormalDisconnectsPs
F-Object Instance
(Location)
RNC
G-Switching
Nortel Confidential
101
H-3GPP Compliance
I-Available Release
V3
This measurement provides the average Number of SCCP connections per Iu interface.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IuAvgNbrSccpCnx.WithCoreNetworkCs.Avg
VS.IuAvgNbrSccpCnx.WithCoreNetworkPs.Avg
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the maximum Number of SCCP connections per Iu interface.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
E-Type
102
VS.IuAvgNbrSccpCnx.WithCoreNetworkCs.Max
VS.IuAvgNbrSccpCnx.WithCoreNetworkPs.Max
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the minimum Number of SCCP connections per Iu interface.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IuAvgNbrSccpCnx.WithCoreNetworkCs.Min
VS.IuAvgNbrSccpCnx.WithCoreNetworkPs.Min
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of RANAP RELOCATION_REQUIRED messages sent by the source RNC on Iu interface.
B-Collection
CC
NORTEL CUM type counter
C-Condition
Nortel Confidential
103
(Event)
D-Result
(Unit)
E-Type
VS.IuRelocationRequired.WithCoreNetworkCS
VS.IuRelocationRequired.WithCoreNetworkPS
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of RANAP RELOCATION_COMMAND messages received by the source RNC on Iu
interface.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IuRelocationCommands.WithCoreNetworkCs
VS.IuRelocationCommands.WithCoreNetworkPs
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
104
This measurement provides the number of RANAP RELOCATION_PREPARATION_FAILURE messages received by the SRNC on Iu CS.
In the case the timer TRELOCAlloc expires, C-Node responses
with Relocation Command Failure cause the relocation time-out.
If a relocation is already in progress, C-Node responses with Relocation Command Failure cause the relocation already in
progress.
Other relocation failures are triggered by the target RNC answering to the C-Node.
The UE being involved in the Relocation, if some requested
RABs are not supported by the target RNC, the cause "relocation
unable to establish" will be provided by the taget RNC to the CNode, then to the source RNC in Reloaction Command Failure.
In the case of lack of resources in the target system, C-Node responses with Relocation Command Failure, cause "Relocation
failure in the target system".
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
F-Object Instance
(Location)
VS.IuRelocationCommandFailuresCs.RejectionDueToTimeou
t
VS.IuRelocationCommandFailuresCs.RejectionDueToAlread
yInProgress
VS.
VS.IuRelocationCommandFailuresCs.RejectionDueToFailureI
nTargetSystem
VS.IuRelocationCommandFailuresCs.RejectionCannotEstabli
shRelocation
VS.IuRelocationCommandFailuresCs.RejectionOtherCauses
RNC
Nortel Confidential
105
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of RANAP RELOCATION_PREPARATION_FAILURE messages received by the SRNC on Iu PS.
In the case the timer TRELOCAlloc expires, C-Node responses
with Relocation Command Failure cause the relocation time-out.
If a relocation is already in progress, C-Node responses with Relocation Command Failure cause the relocation already in
progress.
Other relocation failures are triggered by the target RNC answering to the C-Node.
The UE being involved in the Relocation, if some requested
RABs are not supported by the target RNC, the cause "relocation
unable to establish" will be provided by the taget RNC to the CNode, then to the source RNC in Reloaction Command Failure.
In the case of lack of resources in the target system, C-Node responses with Relocation Command Failure cause relocation failure in the target system.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IuRelocationCommandFailuresPs.RejectionDueToTimeou
t
VS.IuRelocationCommandFailuresPs.RejectionDueToAlready
InProgress
VS.IuRelocationCommandFailuresPs.RejectionDueToFailureI
nTargetSystem
Nortel Confidential
106
VS.IuRelocationCommandFailuresPs.RejectionCannotEstabli
shRelocation
VS.IuRelocationCommandFailuresPs.RejectionOtherCauses
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of timing adjustment requests sent to the CS Core Network.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IuCsTimingAdjustmentRequests.
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of timing adjustment acknowledgement received from the CS Core Network.
B-Collection
CC
NORTEL CUM type counter
C-Condition
Nortel Confidential
107
(Event)
Core Network
D-Result
(Unit)
E-Type
VS.IuCsTimingAdjustmentAcks.
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of negative acknowledgement received from the CS Core Network.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IuCsTimingAdjustmentNacks.
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
108
This measurement provides the number of timing adjustment unsupported received from the CS Core Network.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IuCsTimingAdjustmentUnsupported.
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IuCsTimingAdjustmentTimeouts.
F-Object Instance
(Location)
RNC
Nortel Confidential
109
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of emitted SCCP abnormal disconnections on Iu CS.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IuEmittedSccpAbnormalDisconnectsCs.EndUserOriginate
d
VS.IuEmittedSccpAbnormalDisconnectsCs.EndUserCongesti
on
VS.IuEmittedSccpAbnormalDisconnectsCs.EndUserFailure
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of Iu CS release requests due to the abnormal conditions.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Nortel Confidential
D-Result
(Unit)
110
Unspecified failure
E-Type
VS.IuAbnormalReleaseRequestCs.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V4
This measurement represents the number of Iu PS release requests due to abnormal conditions.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
OAM intervention
Unspecified failure
E-Type
VS.IuAbnormalReleaseRequestPs
F-Object Instance
(Location)
RNC / DlAsConf
Nortel Confidential
111
G-Switching
H-3GPP Compliance
I-Available Release
V4
This measurement provides the number of RANAP RELOCATION_ REQUEST messages received by the target RNC on Iu.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IuRelocationRequests.Cs3Gto3GRelocation
VS.IuRelocationRequests.Ps3Gto3GRelocation
VS.IuRelocationRequests.Cs2Gto3GRelocation
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V4
This measurement provides the number of RANAP RELOCATION_ FAILURE messages sent by the target RNC on Iu-CS, because of the failure of an incoming relocation request.
For Ps, Nortel uses only UE involved relocation procedures, and
they are used here only for incoming Ps 3G to 3G Relocation.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Nortel Confidential
D-Result
(Unit)
E-Type
112
VS.IuRelocationRequestFailuresCs.3Gto3GRejectionDueToT
imeOut
VS.IuRelocationRequestFailuresCs.3Gto3GRejectionDueToF
ailureInTargetSystem
VS.IuRelocationRequestFailuresCs.3Gto3GRejectionCannot
EstablishLocation
VS.IuRelocationRequestFailuresCs.3Gto3GRejection-OtherC
auses
VS.IuRelocationRequestFailuresCs.2Gto3GRejectionDueToT
imeOut
VS.IuRelocationRequestFailuresCs.2Gto3GRejectionDueToF
ailureInTargetSystem
VS.IuRelocationRequestFailuresCs.2Gto3GRejectionCannot
EstablishLocation
VS.IuRelocationRequestFailuresCs.2Gto3GRejectionOtherC
auses
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V4
This measurement provides the number of RANAP RELOCATION_ FAILURE messages sent by the target RNC on Iu-PS, because of the failure of an incoming relocation request.
Nortel Confidential
113
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IuRelocationRequestFailuresPs.3Gto3GRejectionDueToT
imeOut
VS.IuRelocationRequestFailuresPs.3Gto3GRejectionDueToF
ailureInTargetSystem
VS.IuRelocationRequestFailuresPs.3Gto3GRejectionCannot
EstablishLocation
VS.IuRelocationRequestFailuresPs.3Gto3GRejection-OtherC
auses
VS.IuRelocationRequestFailuresPs.2Gto3GRejectionDueToT
imeOut
VS.IuRelocationRequestFailuresPs.2Gto3GRejectionDueToF
ailureInTargetSystem
VS.IuRelocationRequestFailuresPs.2Gto3GRejectionCannot
EstablishLocation
VS.IuRelocationRequestFailuresPs.2Gto3GRejectionOtherCa
uses
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V4
Nortel Confidential
114
Counter name
#0601
VS.RadioBearerSetupSuccess.
#0602
VS.RadioBearerSetupUnsuccess.
#0603
VS.RadioBearerEstablishmentUnsuccess.
#0604
VS.RabAssignmentSetupSuccess.
#0605
VS.RabAssignmentSetupUnsuccess.
#0606
VS.RabAssignmentReleaseSuccess.
#0607
VS.RabAssignmentReleaseUnsuccess.
#0608
VS.RadioBearerReleaseSuccess.
#0609
VS.RadioBearerReleaseUnsuccess.
#0610
VS.RadioBearerSetupSuccessNeighbRnc.
#0611
VS.RadioBearerSetupUnsuccessNeighbRnc.
#0612
VS.RadioBearerEstablishmentUnsuccessNeighbRnc.
#0613
VS.RadioBearerReleaseSuccessNeighbRnc.
#0614
VS.RadioBearerReleaseUnsuccessNeighbRnc.
#0615
VS.RadioBearerReconfigurationSuccess.
#0616
VS.RadioBearerReconfigurationUnsuccess.
#0617
VS.RadioBearerReconfigurationSuccessNeighbRnc.
#0618
VS.RadioBearerReconfigurationUnsuccessNeighbRnc.
#0619
VS.RabAvgNbrEstablished.Cum
VS.RabAvgNbrEstablished.NbEvt
VS.RabAvgNbrEstablished.Avg
VS.RabAvgNbrEstablished.Min
VS.RabAvgNbrEstablished.Max
#0620
VS.UlAsConfIdAvgNbrEstablished.Avg
VS.UlAsConfIdAvgNbrEstablished.Max
VS.UlAsConfIdAvgNbrEstablished.Min
#0621
VS.RabEstablishmentRequestsPerRabType
#0622
VS.RabEstablishmentSuccessPerRequestedRabType
#0623
VS.RabEstablishmentSuccessPerGrantedRabType
Nortel Confidential
115
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioBearerSetupSuccess.
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
The measurement counts the number of RB establishment attempts which have evolved into the emission by the RNC of an
RRC RADIO BEARER SETUP message for which any subsequent RADIO BEARER SETUP COMPLETE message has been
Nortel Confidential
116
received.
The measurement is only incremented when the primary cell of
the UE is under the control of its SRNC.
D-Result
(Unit)
E-Type
Subcounter #0 => Time-out expired without receipt of a RADIO BEARER SETUP COMPLETE message or a RADIO
BEARER SETUP FAILURE message
VS.RadioBearerSetupUnsuccess.Timeout
VS.RadioBearerSetupUnsuccess.RadioBearerSetupFailure
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
The measurement counts the number of RB establishment attempts that have not evolved into the sending a RADIO
BEARER SETUP message.
An RB establishment attempt is considered when the RNC
takes into account a need to establish an RB.
If the RNC considers the need cannot be satisfied, it refuses
the RB establishment and does not send any RADIO BEARER
SETUP message.
The measurement is incremented only when the UE has one or
several cells in its active set that are under the control of its
SRNC.
D-Result
(Unit)
Nortel Confidential
E-Type
117
VS.RadioBearerEstablishmentUnsuccess.InvalidRABPara
metersValue
VS.RadioBearerEstablishmentUnsuccess.UnavailableDLC
odeResources
VS.RadioBearerEstablishmentUnsuccess.UnavailableDLPo
werResources
VS.RadioBearerEstablishmentUnsuccess.Unspecified
F-Object Instance
(Location)
FDDCell.(Reference Cell)
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
RabAssignmentSetupSuccess.Conversational
Nortel Confidential
118
RabAssignmentSetupSuccess.Streaming
RabAssignmentSetupSuccess.Interactive
RabAssignmentSetupSuccess.Background
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RabAssignmentSetupUnsuccess.Conversational
VS.RabAssignmentSetupUnsuccess.Streaming
VS.RabAssignmentSetupUnsuccess.Interactive
VS.RabAssignmentSetupUnsuccess.Background
F-Object Instance
(Location)
RNC
G-Switching
Nortel Confidential
119
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RabAssignmentReleaseSuccess.Conversational
VS.RabAssignmentReleaseSuccess.Streaming
VS.RabAssignmentReleaseSuccess.Interactive
VS.RabAssignmentReleaseSuccess.Background
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
120
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RabAssignmentReleaseUnsuccess.conversational
VS.RabAssignmentReleaseUnsuccess.streaming
VS.RabAssignmentReleaseUnsuccess.interactive
VS.RabAssignmentReleaseUnsuccess.background
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Upon reception by the RNC of an RRC RADIO BEARER RELEASE COMPLETE message, following the emission of an
RRC RADIO BEARER RELEASE message
The measurement is incremented only when the UE has one or
Nortel Confidential
121
several cells in its active set that are under the control of its
SRNC.
D-Result
(Unit)
E-Type
VS.RadioBearerReleaseSuccess.DlAccessStratumConf#i
for i = 0 to 20
Refer to Downlink Access Stratum Configuration.
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
The measurement counts the number of emissions of RRC RADIO BEARER RELEASE messages for which any subsequent
RADIO BEARER RELEASE COMPLETE message has been received.
The measurement is incremented only when the UE has one or
several cells in its active set that are under the control of its
SRNC.
D-Result
(Unit)
Subcounter #0 => Time-out expired without receipt of a RADIO BEARER RELEASE COMPLETE message or a RADIO
BEARER RELEASE FAILURE message
Nortel Confidential
E-Type
122
VS.RadioBearerReleaseUnsuccess.Timeout
VS.RadioBearerReleaseUnsuccess.RadioBearerReleaseFai
lure
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioBearerSetupSuccessNeighbRnc.
for i = 0 to 20
Refer to Downlink Access Stratum Configuration.
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
123
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
The measurement counts the number of RB establishment attempts that have met the following criteria:
E-Type
Subcounter #0 => Time-out expired without receipt of a RADIO BEARER SETUP COMPLETE message or a RADIO
BEARER SETUP FAILURE message
VS.RadioBearerSetupUnsuccessNeighbRnc.Timeout
VS.RadioBearerSetupUnsuccessNeighbRnc.RadioBearerS
etupFailure
F-Object Instance
(Location)
Neighboring RNC
G-Switching
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
124
CC
NORTEL CUM type counter
C-Condition
(Event)
The measurement counts the number of RB establishment attempt that has not evolved into the sending of an RADIO
BEARER SETUP message.
An RB establishment attempt is considered when the RNC
takes into account a need to establish an RB.
If the RNC considers the need can not be satisfied, it refuses
the RB establishment and does not send any RADIO BEARER
SETUP message.
The measurement is only incremented when the UE has one or
several cells in its active set which are outside the control of its
SRNC. The counter is incremented as many times as there are
cells of the active set on this neighboring RNC.
D-Result
(Unit)
E-Type
VS.RadioBearerEstablishmentUnsuccessNeighbRnc.Invali
dRABParametersValue
VS.RadioBearerEstablishmentUnsuccessNeighbRnc.Probl
emRadioResource
VS.RadioBearerEstablishmentUnsuccessNeighbRnc.Unsp
ecified
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
125
CC
NORTEL CUM type counter
C-Condition
(Event)
Upon reception by the RNC of an RRC RADIO BEARER RELEASE COMPLETE message, following the emission of an
RRC RADIO BEARER RELEASE message
The event is considered only when the UE has one or several
cells in its active set that are outside the control of its SRNC.
The counter is incremented as many times as there are cells of
the active set on this neighboring RNC
D-Result
(Unit)
E-Type
VS.RadioBearerReleaseSuccessNeighbRnc.
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
On emission by the RNC of an RRC RADIO BEARER RELEASE message for which any subsequent RADIO BEARER
RELEASE COMPLETE message has been received
The event is considered only when the UE has one or several
cells in its active set that are outside the control of its SRNC.
The counter is incremented as many times as there are cells of
Nortel Confidential
126
E-Type
Subcounter #0 => Time-out expired without receipt of a RADIO BEARER RELEASE COMPLETE message or a RADIO BEARER RELEASE FAILURE message
VS.RadioBearerReleaseUnsuccessNeighbRnc.Timeout
VS.RadioBearerReleaseUnsuccessNeighbRnc.RadioBeare
rReleaseFailure
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of successful RB reconfigurations for each cell controlled by the RNC.
During such a procedure, the measurement attached to a given
cell is incremented if the cell belongs to the active set of the involved UE.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioBearerReconfigurationSuccess.
F-Object Instance
(Location)
Nortel Confidential
127
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of failed RB reconfigurations, which are screened by failure cause for each cell controlled by the RNC.
During such a procedure, the measurement attached to a given
cell is incremented if the cell belongs to the active set of the involved UE.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
Subcounter #0 => Time-out expired without receipt of a RADIO BEARER RECONFIGURATION COMPLETE message
or a RADIO BEARER RECONFIGURATION FAILURE message
VS.RadioBearerReconfigurationUnsuccess.Timeout
VS.RadioBearerReconfigurationUnsuccess.RadioBearerRec
onfigurationFailure
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of successful RB reconfigurations for each neighboring RNC.
Nortel Confidential
128
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioBearerReconfigurationSuccessNeighbRnc.
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of failed RB reconfigurations, which are screened by failure cause for each neighboring RNC.
During such a procedure, the measurement attached to a given
neighboring RNC is incremented as many times as there are
cells in the active set that are controlled by this neighboring
RNC.
B-Collection
CUM (CC)
C-Condition
(Event)
Nortel Confidential
129
E-Type
VS.RadioBearerReconfigurationUnsuccessNeighbRnc.Tim
eout
VS.RadioBearerReconfigurationUnsuccessNeighbRnc.Rad
ioBearerReconfigurationFailure
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RabAvgNbrEstablished.Avg
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
Nortel Confidential
130
NORTEL # 0619
I-Available Release
V3
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RabAvgNbrEstablished.Min
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
131
for i = 0 to 20
Refer to Downlink Access Stratum Configuration.
E-Type
VS.RabAvgNbrEstablished.Avg
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RabAvgNbrEstablished.Min
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the Maximum number of established RAB in the RNS per DL Access Stratum configuration during a reporting period.
B-Collection
SI
Nortel Confidential
132
D-Result
(Unit)
E-Type
VS.RabAvgNbrEstablished.Max
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides average number of established Uplink Access Stratum configuration in the RNS during a reporting
period.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
Establishment and release of a Ul AsConf The number of established UlAsConf is sampled each 100 ms.
D-Result
(Unit)
E-Type
VS.UlAsConfIdAvgNbrEstablished.Avg
F-Object Instance
(Location)
RNC/UlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V4
Nortel Confidential
133
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
Establishment and release of a Ul AsConf The number of established UlAsConf is sampled each 100 ms.
D-Result
(Unit)
E-Type
VS.UlAsConfIdAvgNbrEstablished.Max
F-Object Instance
(Location)
RNC/UlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V4
This measurement provides minimum number of established Uplink Access Stratum configuration in the RNS during a reporting
period.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
Establishment and release of a Ul AsConf The number of established UlAsConf is sampled each 100 ms.
D-Result
(Unit)
E-Type
VS.UlAsConfIdAvgNbrEstablished.Min
F-Object Instance
RNC/UlAsConf
Nortel Confidential
134
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V4
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RabEstablishmentRequestsPerRabType.#
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V4
This measurement provides the number of successful RAB establishment, which are screened per requested RAB type.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RabEstablishmentSuccessPerRequestedRabType
F-Object Instance
(Location)
RNC
G-Switching
Nortel Confidential
135
H-3GPP Compliance
I-Available Release
V4
This measurement provides the number of successful RAB establishments, which are screened per granted RAB type.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RabEstablishmentSuccessPerGrantedRabType
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V4
Nortel Confidential
136
Counter name
#0701
VS.SmcSuccess.
#0702
VS.RejectedSmc.
#0703
VS.FailedSmc.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.SmcSuccess.WithCoreNetworkCs
VS.SmcSuccess.WithCoreNetworkPs
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of failed RANAP Security Mode Command procedures screened by Core Network do-
Nortel Confidential
137
main.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RejectedSmc.WithCoreNetworkCs
VS.RejectedSmc.WithCoreNetworkPs
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.FailedSmc.WithCoreNetworkCs
VS.FailedSmc.WithCoreNetworkPs
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
Nortel Confidential
I-Available Release
138
V3
Nortel Confidential
139
Paging counters
This section describes all the Paging counters for RAN V4.0 of the UMTS V4.0 system release.
The associated counters indicate the number of paging records.
The following table lists all the Paging counters.
Table 163 Paging counters
Nortel counter number
Counter name
#0017
VS.PagingSleepyCellInactivity
#0801
VS.ReceivedPagingRequest.
#0802
VS.ReceivedPagingRequestType2CellDch.
#0803
VS.ReceivedPagingRequestType2CellFach.
#0804
VS.PagingRecordsSentOnPcch
#0805
VS.PagingMessagesSentOnPcch
#0806
VS.PagingUnscheduledRecords
#0807
VS.PagingCancelledRecords
#0808
VS.PagingRejectedRequests
#0809
VS.PagingDelayedRecords
#0810
VS.UnhandledPagingRequestsCs.
#0811
VS.UnhandledPagingRequestsPs.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.PagingSleepyCellInactivity
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
Nortel Confidential
140
I-Available Release
V4
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.ReceivedPagingRequest.WithCoreNetworkCs
VS.ReceivedPagingRequest.WithCoreNetworkPs
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of received Type 2 paging requests for UEs in CELL_DCH state screened by Core Network domain. This paging is sent on DCCH.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.ReceivedPagingRequestType2CellDch.WithCoreNetworkCs
VS.ReceivedPagingRequestType2CellDch.WithCoreNetworkPs
Nortel Confidential
141
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of received Type 2 paging requests for UEs in CELL_FACH state screened by Core Network domain. This paging is sent on DCCH.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.ReceivedPagingRequestType2CellFach.WithCoreNetworkCs
VS.ReceivedPagingRequestType2CellFach.WithCoreNetworkPs
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
On emission on the PCCH of the cell of the last paging message that contains a particular paging record
Nortel Confidential
142
E-Type
VS.PagingRecordsSentOnPcch
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.PagingMessagesSentOnPcch
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
143
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.PagingUnscheduledRecords
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Nortel Confidential
144
E-Type
VS.PagingCancelledRecords
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.PagingRejectedRequests
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
Nortel Confidential
145
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.PagingDelayedRecords
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of CS paging type 1 requests that have been not handled by RNC.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
Subcounter #0 => invalid format (for example, ASN.1 decoding error of RANAP message or ASN.1 encoding error of
paging record)
Subcounter #3 => internal resources not available (no memory to allocate messaging buffers)
VS.UnhandledPagingRequestsCs.InvalidFormat
VS.UnhandledPagingRequestsCs.InvalidInformation
VS.UnhandledPagingRequestsCs.ResetInProgress
Nortel Confidential
146
VS.UnhandledPagingRequestsCs.InternalResourcesNotAva
ilable
VS.UnhandledPagingRequestsCs.OverloadControls
VS.UnhandledPagingRequestsCs.OtherCause
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V4
This measurement provides the number of PS paging type 1 requests that have been not handled by RNC.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
Subcounter #0 => invalid format (for example, ASN.1 decoding error of RANAP message or ASN.1 encoding error of
paging record)
Subcounter #3 => internal resources not available (no memory to allocate messaging buffers)
VS.UnhandledPagingRequestsPs.InvalidFormat
VS.UnhandledPagingRequestsPs.InvalidInformation
VS.UnhandledPagingRequestsPs.ResetInProgress
VS.UnhandledPagingRequestsPs.InternalResourcesNotAva
ilable
VS.UnhandledPagingRequestsPs.OverloadControls
VS.UnhandledPagingRequestsPs.OtherCause
Nortel Confidential
147
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V4
Nortel Confidential
148
Counter name
#0901
VS.NbrCellUpdates.
#0902
VS.NbrCellUpdateRejects.
#0903
VS.CsLocationReportingControlDefaultLs
#0904
VS.CsLocationReportingControlEmergencyLs
#0905
VS.PsLocationReportingControlDefaultLs
#0906
VS.CsLocationReportSuccessDefaultLsWithinQoS
#0907
VS.CsLocationReportUnsuccessDefaultLs.
#0908
VS.CsLocationReportSuccessEmergencyLsWithinQoS.UeBased
Agps
#0909
VS.CsLocationReportSuccessEmergencyLsOutsideQoS.CellId
#0910
VS.CsLocationReportUnsuccessEmergencyLs.
#0911
VS.PsLocationReportSuccessDefaultLsWithinQoS
#0912
VS.PsLocationReportUnsuccessDefaultLs.
#0913
VS.CsLocationUebasedAgpsSuccess
#0914
VS.CsLocationUebasedAgpsUnsuccess.
#0915
VS.UeLocationUebasedAgpsSuccess.
#0916
VS.UeLocationUebasedAgpsSuccessNeighbRnc.
#0917
VS.UeLocationUebasedAgpsUnsuccess.
#0918
VS.UeLocationUebasedAgpsUnsuccessNeighbRnc.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
E-Type
149
VS.NbrCellUpdates.CellReselection
VS.NbrCellUpdates.PeriodicCellUpdate
VS.NbrCellUpdates.UplinkDataTransmission
VS.NbrCellUpdates.PagingResponse
VS.NbrCellUpdates.ReenteredServiceArea
VS.NbrCellUpdates.RadioLinkFailure
VS.NbrCellUpdates.RlcUnrecoverableError
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.NbrCellUpdateRejects.UnknownU-RNTI
Nortel Confidential
150
VS.NbrCellUpdateRejects.IncorrectMessage
VS.NbrCellUpdateRejects.AbortedByANewerCellUpdate
VS.NbrCellUpdateRejects.Other
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of RANAP Location Reporting Control messages received from the CS Core Network
for geographical purposed and served with a default location
service.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CsLocationReportingControlDefaultLs
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of RANAP Location Reporting Control messages received from the CS Core Network
for geographical purposed and served with an ermergency location service.
B-Collection
CC
NORTEL CUM type counter
Nortel Confidential
151
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CsLocationReportingControlEmergencyLs
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of RANAP Location Reporting Control messages received from the PS Core Network
for geographical purpose and served with a default location service.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Reception from the Packet Core of a valid RANAP Location Reporting Control message with Report Area message parameter
set to 'Geographical Area' and selection of Defaut Location service
D-Result
(Unit)
E-Type
VS.PsLocationReportingControlDefaultLs
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of RANAP Location Report messages sent to the CS Core Network for geographical
purpose served with a default location service.
Nortel Confidential
152
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CsLocationReportSuccessDefaultLsWithinQoS
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of RANAP failed Location Report messages sent to the CS Core Network for geographical purpose that were supposed to be served with a default location service.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CsLocationReportUnsuccessDefaultLs.LocalCellInfoNot
Found
VS.CsLocationReportUnsuccessDefaultLs.DistantCellInfoNo
tFound
VS.CsLocationReportUnsuccessDefaultLs.Unknown
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
Nortel Confidential
153
NORTEL # 0907
I-Available Release
V3
This measurement provides the number of RANAP Location Report messages sent to the CS Core Network for geographical
purpose served with an ermergency location service.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CsLocationReportSuccessEmergencyLsWithinQoS.UeBase
dAgps
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of RANAP Location Report messages sent to the CS Core Network for geographical
purpose served with an ermergency location service.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CsLocationReportSuccessEmergencyLsOutsideQoS.CellId
F-Object Instance
RNC
Nortel Confidential
154
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of RANAP failed Location Report messages sent to the CS Core Network for geographical purpose that were supposed to be served with an
emergency location service.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CsLocationReportUnsuccessEmergencyLs.LocalCellInfo
NotFound
VS.CsLocationReportUnsuccessEmergencyLs.DistantCellInf
oNotFound
VS.CsLocationReportUnsuccessEmergencyLs.RelocationPr
ocedure
VS.CsLocationReportUnsuccessEmergencyLs.AbortProced
ure
VS.CsLocationReportUnsuccessEmergencyLs.Unknown
F-Object Instance
(Location)
RNC
G-Switching
Nortel Confidential
155
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of RANAP Location Report messages sent to the PS Core Network for geographical
purpose served with a default location service.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.PsLocationReportSuccessDefaultLsWithinQoS
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of RANAP failed Location Report messages sent to the PS Core Network for geographical purpose that were supposed to be served with a default location service.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
E-Type
156
VS.PsLocationReportUnsuccessDefaultLs.LocalCellInfoNotF
ound
VS.PsLocationReportUnsuccessDefaultLs.DistantCellInfoNo
tFound
VS.PsLocationReportUnsuccessDefaultLs.Unknown
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CsLocationUebasedAgpsSuccess
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Nortel Confidential
D-Result
(Unit)
E-Type
157
VS.CsLocationUebasedAgpsUnsuccess.SasServicesNotAva
ilable
VS.CsLocationUebasedAgpsUnsuccess.SasPcapFailure
VS.CsLocationUebasedAgpsUnsuccess.UePositiniongError
VS.CsLocationReportUnsuccessEmergencyLs.AgpsUE-bas
edTooLong
VS.CsLocationUebasedAgpsUnsuccess.Other
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
Subcounter #1 => UE position estimated with uncertainty between 50 and 150 meters
Nortel Confidential
158
VS.UeLocationUebasedAgpsSuccess.UeEstimatedAccuracy
BetterThan50m
VS.UeLocationUebasedAgpsSuccess.UeEstimatedAccuracy
Between50mAnd150m
VS.UeLocationUebasedAgpsSuccess.UeEstimatedAccurary
WorseThan150m
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
F-Object Instance
Subcounter #1 => UE position estimated with uncertainty between 50 and 150 meters
VS.UeLocationUebasedAgpsSuccessNeighbRnc.UeEstimat
edAccuracyBetterThan50m
VS.UeLocationUebasedAgpsSuccessNeighbRnc.UeEstimat
edAccuracyBetween50mAnd150m
VS.UeLocationUebasedAgpsSuccessNeighbRnc.UeEstimat
edAccuraryWorseThan150m
Neighboring RNC
Nortel Confidential
159
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CsLocationUebasedAgpsUnsuccess.SasServicesNotAva
ilable
VS.CsLocationUebasedAgpsUnsuccess.SasPcapFailure
VS.CsLocationUebasedAgpsUnsuccess.UePositiniongError
VS.CsLocationReportUnsuccess.AgpsUE-basedTooLong
VS.CsLocationUebasedAgpsUnsuccess.Other
F-Object Instance
(Location)
FDDCell (Reference)
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
160
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CsLocationUebasedAgpsUnsuccessNeighbRnc.SasServ
icesNotAvailable
VS.CsLocationUebasedAgpsUnsuccessNeighbRnc.SasPca
pFailure
VS.CsLocationUebasedAgpsUnsuccessNeighbRnc.UePositi
niongError
VS.CsLocationReportUnsuccessNeighbRnc.AgpsUE-based
TooLong
VS.CsLocationUebasedAgpsUnsuccessNeighbRnc.Other
F-Object Instance
(Location)
Neighboring RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
161
Counter name
#1001
VS.IrmcacDistributionEcN0.
#1002
VS.AvgTxPower.Cum
VS.AvgTxPower.NbEvt
VS.AvgTxPower.Avg
VS.AvgTxPower.Max
VS.AvgTxPower.Min
#1003
VS.CmConfigurationFailure
#1004
VS.CmActivationSuccess
#1005
VS.CmActivationFailure
#1006
VS.CmConfigurationSuccess.
#1007
VS.IntraFreqMeasPeriodicModeEventModeCell
#1008
VS.IntraFreqMeasPeriodicModeToEventModeNeighbRnc
#1009
VS.IntraFreqMeasEventModeToPeriodicModeCell
#1010
VS.IntraFreqMeasEventModeToPeriodicModeNeighbRnc
#1011
VS.IntraFreqMeasAverageOfCallPeriodicModeCell.Avg
VS.IntraFreqMeasAverageOfCallPeriodicModeCell.Max
VS.IntraFreqMeasAverageOfCallPeriodicModeCell.Min
#1012
VS.IntraFreqMeasAverageOfCallPeriodicModeNeighbRnc.Avg
VS.IntraFreqMeasAverageOfCallPeriodicModeNeighbRnc.Max
VS.IntraFreqMeasAverageOfCallPeriodicModeCell.Min
#1013
VS.IntraFreqMeasAverageOfCallEventModeCell.Avg
VS.IntraFreqMeasAverageOfCallEventModeCell.Max
VS.IntraFreqMeasAverageOfCallEventModeCell.Min
#1014
VS.IntraFreqMeasAverageOfCallEventModeNeighRnc.Avg
VS.IntraFreqMeasAverageOfCallEventModeNeighRnc.Max
VS.IntraFreqMeasAverageOfCallEventModeNeighRnc.Min
#1015
VS.MeasurementControlFailure
Nortel Confidential
162
A-Description
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IrmcacDistributionEcN0.Minus24DbToMoreThanMinus1
8Db
VS.IrmcacDistributionEcN0.Minus18DbToMoreThanMinus1
2Db
VS.IrmcacDistributionEcN0.Minus12DbToMoreThanMinus6
Db
VS.IrmcacDistributionEcN0.Minus6DbToMoreThan0Db
F-Object Instance
(Location)
FDDCell
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
This measurement indicates the value of Tx power measurements coming from a cell during a reporting period.
B-Collection
SI
NORTEL LOAD type counter ("Cumulating value" part)
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AvgTxPower.Cum
F-Object Instance
FDDCell
Nortel Confidential
163
(Location)
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
This measurement indicates the number of Tx power measurements coming from a cell during a reporting period.
B-Collection
SI
NORTEL LOAD type counter ("Number of events" part)
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AvgTxPower.NbEvt
F-Object Instance
(Location)
FDDCell
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
This measurement indicates the average of Tx power measurements coming from a cell during a reporting period.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AvgTxPower.Avg
F-Object Instance
(Location)
FDDCell
G-Switching
N/A
Nortel Confidential
164
H-3GPP Compliance
I-Available Release
V3
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AvgTxPower.Max
F-Object Instance
(Location)
FDDCell
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AvgTxPower.Min
F-Object Instance
(Location)
FDDCell
G-Switching
N/A
H-3GPP Compliance
Nortel Confidential
I-Available Release
165
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
On failed Compressed Mode configuration due to bad CM parameter setting by the BTS in NBAP RL Setup/Reconfiguration
Failure or by the UE in RRC RB Setup/Reconfiguration Failure
D-Result
(Unit)
E-Type
VS.CmConfigurationFailure.Gsm
VS.CmConfigurationFailure.InterFrequency
VS.CmConfigurationFailure.GsmAndInterFrequency
F-Object Instance
(Location)
RNC
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
E-Type
166
VS.CmActivationSuccess.Gsm
VS.CmActivationSuccess.InterFrequency
F-Object Instance
(Location)
RNC
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CmActivationFailure.Gsm
VS.CmActivationFailure.InterFrequency
F-Object Instance
(Location)
FDDCell
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Nortel Confidential
D-Result
(Unit)
E-Type
167
VS.CmConfigurationSuccess.Gsm
VS.CmConfigurationSuccess.InterFrequency
VS.CmConfigurationSuccess.GsmAndInterFrequency
F-Object Instance
(Location)
RNC
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IntraFreqMeasPeriodicModeEventModeCell
F-Object Instance
(Location)
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
168
A-Description
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
A transition to event-triggered mode for a mobile that is in periodic mode. The counter is only incremented on the primary cell
of the active set.
D-Result
(Unit)
E-Type
VS.IntraFreqMeasPeriodicModeToEventModeNeighbRnc
F-Object Instance
(Location)
Neighboring RNC
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IntraFreqMeasEventModeToPeriodicModeCell
F-Object Instance
(Location)
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
169
counter.
Table 209 VS.IntraFreqMeasEventModeToPeriodicModeNeighbRnc (Radio Measurement)
A-Description
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IntraFreqMeasEventModeToPeriodicModeNeighbRnc
F-Object Instance
(Location)
Neighboring RNC
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
a call has elected this cell as its primary cell after a soft handover.
a call having this cell as its primary cell has switched from
event to periodic mode
This measurement is decremented if the following conditions are
met:
a call having this cell as its primary cell has switched from
periodic to event mode
Nortel Confidential
170
a call having the cell as primary cell has changed its primary
cell after a soft handover.
a call in periodic mode having cell as primary cell has terminated.to be handled in UE call.
D-Result
(Unit)
E-Type
VS.IntraFreqMeasAverageOfCallPeriodicModeCell.Avg
F-Object Instance
(Location)
FDDCell
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
a call has elected this cell as its primary cell after a soft handover.
a call having this cell as its primary cell has switched from
event to periodic mode
This measurement is decremented if the following conditions are
met:
a call having this cell as its primary cell has switched from
periodic to event mode
a call having the cell as primary cell has changed its primary
cell after a soft handover.
a call in periodic mode having cell as primary cell has terminated.to be handled in UE call.
D-Result
(Unit)
E-Type
VS.IntraFreqMeasAverageOfCallPeriodicModeCell.Max
F-Object Instance
Nortel Confidential
171
(Location)
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
a call has elected this cell as its primary cell after a soft handover.
a call having this cell as its primary cell has switched from
event to periodic mode
This measurement is decremented if the following conditions are
met:
a call having this cell as its primary cell has switched from
periodic to event mode
a call having the cell as primary cell has changed its primary
cell after a soft handover.
a call in periodic mode having cell as primary cell has terminated.to be handled in UE call.
D-Result
(Unit)
E-Type
VS.IntraFreqMeasAverageOfCallPeriodicModeCell.Min
F-Object Instance
(Location)
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
172
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
a call having this cell as its primary cell has switched from
event to periodic mode
a call having this cell as its primary cell has switched from
periodic to event mode
a call in periodic mode has elected another cell as its primary cell (soft handover)
E-Type
VS.IntraFreqMeasAverageOfCallPeriodicModeNeighbRnc.Avg
F-Object Instance
(Location)
Neighboring RNC
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
SI
Nortel Confidential
173
a call in periodic mode has elected a primary cell that is located under this neighboring RNC (after soft handover) and
the former primary cell was under another RNC
This measurement is decremented if the following conditions are
met:
E-Type
VS.IntraFreqMeasAverageOfCallPeriodicModeNeighbRnc.Max
F-Object Instance
(Location)
Neighboring RNC
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
a call in periodic mode has elected a primary cell that is located under this neighbouring RNC (after soft handover) and
Nortel Confidential
174
E-Type
VS.IntraFreqMeasAverageOfCallPeriodicModeNeighbRnc.Min
F-Object Instance
(Location)
Neighboring RNC
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
E-Type
VS.IntraFreqMeasAverageOfCallEventModeCell.Avg
Nortel Confidential
175
F-Object Instance
(Location)
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
E-Type
VS.IntraFreqMeasAverageOfCallEventModeCell.Max
F-Object Instance
(Location)
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
SI
Nortel Confidential
176
E-Type
VS.IntraFreqMeasAverageOfCallEventModeCell.Min
F-Object Instance
(Location)
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
a call having its primary cell under this RNC has switched
from event to periodic mode
a call in event mode having its primary cell under this RNC
has terminated
This number of mobiles is sampled each 100ms.
D-Result
(Unit)
Nortel Confidential
177
E-Type
VS.IntraFreqMeasAverageOfCallEventModeNeighRnc.Avg
F-Object Instance
(Location)
Neighboring RNC
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
a call having its primary cell under this RNC has switched
from event to periodic mode
a call in event mode having its primary cell under this RNC
has terminated.
This number of mobiles is sampled each 100ms.
D-Result
(Unit)
E-Type
VS.IntraFreqMeasAverageOfCallEventModeNeighRnc.Max
F-Object Instance
(Location)
Neighboring RNC
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
178
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
a call having its primary cell under this RNC has switched
from event to periodic mode
a call in event mode having its primary cell under this RNC
has terminated
This number of mobiles is sampled each 100ms.
D-Result
(Unit)
E-Type
VS.IntraFreqMeasAverageOfCallEventModeNeighRnc.Min
F-Object Instance
(Location)
Neighboring RNC
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.MeasurementControlFailure
F-Object Instance
(Location)
FDDCell
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V4
Nortel Confidential
179
Counter name
#1101
VS.DownsizingStep1Success.
#1102
VS.DownsizingStep1SuccessNeighbRnc.
#1103
VS.DownsizingStep1Unuccess.
#1104
VS.DownsizingStep1UnsuccessNeighbRnc.
#1105
VS.DownsizingStep2Success.
#1106
VS.DownsizingStep2SuccessNeighbRnc.
#1107
VS.UpsizingSuccess.
#1108
VS.UpsizingSuccessNeighbRnc.
#1109
VS.UpsizingUnsuccess.
#1110
VS.UpsizingUnsuccessNeighbRnc.
#1111
VS.IrmcacMaintainedHighPriority.
#1112
VS.IrmcacDowngradedHighPriority.
#1113
VS.IrmcacRejectedHighPriority.
#1114
VS.IrmcacMaintainedMediumPriority.
#1115
VS.IrmcacDowngradedMediumPriority.
#1116
VS.IrmcacRejectedMediumPriority.
#1117
VS.IrmcacMaintainedLowPriority.
#1118
VS.IrmcacDowngradedLowPriority.
#1119
VS.IrmcacRejectedLowPriority.
#1120
VS.IRMSchedulingDowngradedSuccess.
#1121
VS.IRMSchedulingDowngradedFailure.
#1122
VS.IRMSchedulingDowngradedSuccessNeighbRnc.
#1123
VS.IRMSchedulingDowngradedFailureNeighbRnc.
#1124
VS.IRMTimeCellColorRed
#1125
VS.IRMTimeCellColorYellow
#1126
VS.IRMTimeFreeDlCodesBySpreadingFactor.#i.Avg
VS.IRMTimeFreeDlCodesBySpreadingFactor.#i.Max
VS.IRMTimeFreeDlCodesBySpreadingFactor.#i.Min
#1127
VS.IRMTimeCellColorGreen
Nortel Confidential
180
Counter name
#1128
VS.IrmcacDistributionRscp.
#1129
VS.IrmcacRadioLinkColorRed
#1130
VS.IrmcacRadioLinkColorGreen
This measurement provides the number of successful downsizing steps 1 screened by Downlink Access Stratum Configuration
for each cell controlled by the RNC.
The measurement attached to a given cell is incremented if the
cell is the reference cell of the involved UE.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DownsizingStep1Success.
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of successful downsizing steps 1 screened by Downlink Access Stratum Configuration, for each neighboring RNC.
Nortel Confidential
181
The measurement attached to a neighboring RNC is incremented if the neighboring RNC controls the reference cell of the
involved UE.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
On successfull implementation of an "Always On" algorithm decision to dowgrade the UE capabilities to the "Always On" radio
configuration
It is stated on receipt of a RRC RB RECONFIGURATION COMPLETE message consistent with the required downgraded capabilities.
The measurement is incremented only when the UE has a reference cell outside the control of the RNC in charge of the measurement.
D-Result
(Unit)
E-Type
VS.DownsizingStep1SuccessNeighbRnc.
F-Object Instance
(Location)
Neighboring RNC
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of Unsuccessful downsizing steps 1 screened by Downlink Access Stratum Configuration for each cell controlled by the RNC.
The measurement attached to a given cell is incremented if the
cell is the reference cell of the involved UE.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Nortel Confidential
182
ence cell under the control of the RNC in charge of the measurement.
D-Result
(Unit)
E-Type
VS.DownsizingStep1Unuccess.DlAccessStratumConf#i
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of unsuccessful downsizing steps 1 screened by Downlink Access Stratum Configuration for each neighboring RNC.
The measurement attached to a neighboring RNC is incremented if the neighboring RNC controls the reference cell of the
involved UE.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DownsizingStep1UnsuccessNeighbRnc.
F-Object Instance
Neighboring RNC
Nortel Confidential
183
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of successful downsizing steps 2 screened by Downlink Access Stratum Configuration
for each cell controlled by the RNC.
The measurement attached to a given cell is incremented if the
cell is the reference cell of the involved UE.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
On successfull implementation of an "Always On" algorithm decision to release an UE call due to the UE inactivity
It is stated on receipt of a RRC RB RELEASE COMPLETE message for "User inactivity" reason.
The measurement is incremented only when the UE has a reference cell under the control of the RNC in charge of the measurement.
D-Result
(Unit)
E-Type
VS.DownsizingStep2Success.
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of successful downsizing steps 2 screened by Downlink Access Stratum Configuration
for each neighboring RNC.
Nortel Confidential
184
The measurement attached to a neighboring RNC is incremented if the neighboring RNC controls the reference cell of the
involved UE.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
On successfull implementation of an "Always On" algorithm decision to release an UE call due to the UE inactivity.
It is stated on receipt of a RRC RB RELEASE COMPLETE message for "User inactivity".
The measurement is incremented only when the UE has a reference cell outside the control of the RNC in charge of the measurement.
D-Result
(Unit)
E-Type
VS.DownsizingStep2SuccessNeighbRnc.
F-Object Instance
(Location)
Neighboring RNC
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
On successfull implementation of an "Always On" algorithm decision to restore the full UE capabilities
It is stated on receipt of a RRC RB RECONFIGURATION COMPLETE message consistent with the required upgraded capabilities.
The measurement is incremented only when the UE has a reference cell under the control of the RNC in charge of the measurement.
Nortel Confidential
D-Result
(Unit)
185
E-Type
VS.UpsizingSuccess.
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
On successfull implementation of an "Always On" algorithm decision to restore the full UE capabilities
It is stated on receipt of a RRC RB RECONFIGURATION COMPLETE message consistent with the required upgraded capabilities.
The measurement is incremented only when the UE has a reference cell outside the control of the RNC in charge of the measurement.
D-Result
(Unit)
E-Type
VS.UpsizingSuccessNeighbRnc.
F-Object Instance
(Location)
Neighboring RNC
G-Switching
Nortel Confidential
186
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of unsuccessful upsizings, which are screened by Downlink Access Stratum Configuration for each cell controlled by the RNC.
The measurement attached to a given cell is incremented if the
cell is the reference cell of the involved UE
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.UpsizingUnsuccess.
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of unsuccessful upsizings, which are screened by Downlink Access Stratum Configuration, for each neighboring RNC.
The measurement attached to a neighboring RNC is incremented if the neighboring RNC controls the reference cell of the
involved UE.
Nortel Confidential
187
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.UpsizingUnsuccessNeighbRnc.
F-Object Instance
(Location)
Neighboring RNC
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IrmcacMaintainedHighPriority.
F-Object Instance
(Location)
RNC
Nortel Confidential
188
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IrmcacDowngradedHighPriority.
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
189
for i = 0 to 14
Refer to Downlink Radio Bearer Set
E-Type
VS.IrmcacRejectedHighPriority.
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IrmcacMaintainedMediumPriority.
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
Nortel Confidential
190
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IrmcacDowngradedMediumPriority.
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IrmcacRejectedMediumPriority.
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
191
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IrmcacMaintainedLowPriority.
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IrmcacDowngradedLowPriority.
F-Object Instance
(Location)
RNC
Nortel Confidential
192
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IrmcacRejectedLowPriority.
F-Object Instance
(Location)
RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
Nortel Confidential
(Unit)
193
Stratum configuration.
Screening is as follows:
Subcounter #i => DlAccessStratumConf#i
for i = 0 to 20
Refer to Downlink Access Stratum Configuration.
E-Type
VS.IRMSchedulingDowngradedSuccess.
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IRMSchedulingDowngradedFailure.
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
194
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IRMSchedulingDowngradedSuccessNeighbRnc.
F-Object Instance
(Location)
NeighbouringRNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
Nortel Confidential
195
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IRMSchedulingDowngradedFailureNeighbRnc.
F-Object Instance
(Location)
NeighbouringRNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
DER
NORTEL VAL type counter
C-Condition
(Event)
IRM changes cell color to or from red (if 1, else 0). This cell
color is sampled each 100ms.
D-Result
(Unit)
E-Type
VS.IRMTimeCellColorRed.Avg
VS.IRMTimeCellColorRed.Max
VS.IRMTimeCellColorRed.Min
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
196
B-Collection
DER
NORTEL VAL type counter
C-Condition
(Event)
IRM changes cell color to or from yellow (if 1, else 0). This cell
color is sampled each 100ms.
D-Result
(Unit)
E-Type
VS.IRMTimeCellColorYellow
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the average number of free downlink channelization codes per spreading factor during a reporting period.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IRMTimeFreeDlCodesBySpreadingFactor.4.Avg
VS.IRMTimeFreeDlCodesBySpreadingFactor.8.Avg
Nortel Confidential
197
VS.IRMTimeFreeDlCodesBySpreadingFactor.16.Avg
VS.IRMTimeFreeDlCodesBySpreadingFactor.32.Avg
VS.IRMTimeFreeDlCodesBySpreadingFactor.64.Avg
VS.IRMTimeFreeDlCodesBySpreadingFactor.128.Avg
VS.IRMTimeFreeDlCodesBySpreadingFactor.256.Avg
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
Counter introduced in V3
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IRMTimeFreeDlCodesBySpreadingFactor.4.Max
VS.IRMTimeFreeDlCodesBySpreadingFactor.8.Max
VS.IRMTimeFreeDlCodesBySpreadingFactor.16.Max
VS.IRMTimeFreeDlCodesBySpreadingFactor.32.Max
VS.IRMTimeFreeDlCodesBySpreadingFactor.64.Max
VS.IRMTimeFreeDlCodesBySpreadingFactor.128.Max
VS.IRMTimeFreeDlCodesBySpreadingFactor.256.Max
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
Nortel Confidential
I-Available Release
198
Counter introduced in V3
This measurement provides the minimum number of free downlink channelization codes per spreading factor during a reporting period.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IRMTimeFreeDlCodesBySpreadingFactor.4.Min
VS.IRMTimeFreeDlCodesBySpreadingFactor.8.Min
VS.IRMTimeFreeDlCodesBySpreadingFactor.16.Min
VS.IRMTimeFreeDlCodesBySpreadingFactor.32.Min
VS.IRMTimeFreeDlCodesBySpreadingFactor.64.Min
VS.IRMTimeFreeDlCodesBySpreadingFactor.128.Min
VS.IRMTimeFreeDlCodesBySpreadingFactor.256.Min
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
Counter introduced in V3
This measurement provides the ratio of time if a cell is considered green by the iRM during a reporting period (Average
value).
The minimum value allows to know if the cell has never been
considered green by the iRM during the reporting period.
Nortel Confidential
199
The maximum value allows to know if the cell has been considered green, at least once, by the iRM during the reporting period.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IRMTimeCellColorGreen.Avg
VS.IRMTimeCellColorGreen.Min
VS.IRMTimeCellColorGreen.Max
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the distribution of RSCP measurements received from UEs with that reference cell of time.
B-Collection
CC
NORTEL VAL type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IrmcacDistributionRscp.Minus115DbToMoreThanMinus
Nortel Confidential
200
97Db
VS.IrmcacDistributionRscp.Minus97DbToMoreThanMinus7
9Db
VS.IrmcacDistributionRscp.Minus79DbToMoreThanMinus6
1Db
VS.IrmcacDistributionRscp.Minus61DbToMoreThanMinus4
3Db
VS.IrmcacDistributionRscp.Minus43DbToMoreThanMinus2
5Db
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IrmcacRadioLinkColorRed
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
201
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IrmcacRadioLinkColorGreen
F-Object Instance
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
202
Counter name
#1213
VS.CommonMacDownlinkPcchSdu
#1214
VS.CommonMacDownlinkCcchSdu
#1215
VS.CommonMacDownlinkDcchOverFachSdu
#1216
VS.CommonMacDownlinkDtchOverFachSdu
#1217
VS.CommonMacUplinkCcchSdu
#1218
VS.CommonMacUplinkDcchOverRachSdu
#1219
VS.CommonMacUplinkDtchOverRachSdu
#1220
VS.CommonRlcCcchDownlinkKbytes
#1221
VS.CommonRlcCcchDownlinkSdu
#1222
VS.CommonRlcCcchDiscardSdu
#1223
VS.CommonRlcCcchPadding
#1224
VS.CommonUplinkTrafficChnlSyncFrames
#1225
VS.CommonUplinkTimingAdjustmentFrames
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CommonMacDownlinkPcchSdu
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
Nortel Confidential
I-Available Release
203
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CommonMacDownlinkCcchSdu
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CommonMacDownlinkDcchOverFachSdu
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
204
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CommonMacDownlinkDtchOverFachSdu
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CommonMacUplinkCcchSdu
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
205
link direction.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CommonMacUplinkDcchOverRachSdu
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CommonMacUplinkDtchOverRachSdu
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the total count of downlink RLC payload on CCCH.
B-Collection
CC
NORTEL CUM type counter
Nortel Confidential
206
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CommonRlcCcchDownlinkKbytes
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CommonRlcCcchDownlinkSdu
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
Nortel Confidential
207
(Unit)
Screening = NO
E-Type
VS.CommonRlcCcchDiscardSdu
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CommonRlcCcchPadding
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CommonUplinkTrafficChnlSyncFrames
F-Object Instance
FDDCell
Nortel Confidential
208
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CommonUplinkTimingAdjustmentFrames
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
209
Counter name
#1301
VS.IurDrncRadioLinkSetupSuccess.
#1302
VS.IurDrncRadioLinkSetupUnsuccess.
#1303
VS.IurDrncRadioLinkAdditionSuccess.
#1304
VS.IurDrncRadioLinkAdditionUnsuccess.
#1306
VS.IurDrncRadioLinkDeletionSuccess
#1307
VS.IurDrncRadioLinkReconfigurationPrepareSuccess.
#1308
VS.IurDrncRadioLinkReconfigurationPrepareUnsuccess.
#1309
VS.IurDrncRadioLinkReconfigurationCancelSuccess.
#1310
VS.IurDrncRadioLinkReconfigurationCommitSuccess.
This measurement provides the number of radio links successfully setup on an RNSAP point of view, which are screened by
Downlink Access Stratum configuration.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IurDrncRadioLinkSetupSuccess.
Nortel Confidential
210
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
F-Object Instance
VS.IurDrncRadioLinkSetupUnsuccess.Unspecified
VS.IurDrncRadioLinkSetupUnsuccess.NoRadioResource
VS.IurDrncRadioLinkSetupUnsuccess.NbapRefusal
VS.IurDrncRadioLinkSetupUnsuccess.RequestedConfiguratio
nNotSupport
FDDCell
Nortel Confidential
211
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of radio links successfully added on an RNSAP point of view, which are screened by
Downlink Access Stratum configuration.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Upon receipt of an RADIO LINK ADDITION RESPONSE or RADIO LINK ADDITION FAILURE RNSAP message sent by the
Drift RNC to the Serving RNC in response to an RADIO LINK
ADDITION REQUEST message
The measurement consider each Radio Link mentioned as added
in the RADIO LINK ADDITION RESPONSE or RADIO LINK ADDITION FAILURE RNSAP message
D-Result
(Unit)
E-Type
VS.IurDrncRadioLinkAdditionSuccess.
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of radio links failed in addition on an RNSAP point of view, which are screened by addition failure cause.
B-Collection
CC
NORTEL CUM type counter
Nortel Confidential
C-Condition
(Event)
212
Upon receipt of an RNSAP RADIO LINK ADDITION FAILURE message sent by the Drift RNC to the Serving RNC in
response to an RADIO LINK ADDITION REQUEST message
The measurement considers each Radio Link referred as
failed in the RNSAP RADIO LINK ADDITION FAILURE message.
On time-out expired without receipt of an RADIO LINK ADDITION RESPONSE or RADIO LINK ADDITION FAILURE
message
The measurement considers each Radio Link required to addition in the RNSAP RADIO LINK ADDITION REQUEST
message.
D-Result
(Unit)
E-Type
VS.IurDrncRadioLinkAdditionUnsuccess.Unspecified
VS.IurDrncRadioLinkAdditionUnsuccess.NoRadioResource
VS.IurDrncRadioLinkAdditionUnsuccess.NbapRefusal
VS.IurDrncRadioLinkAdditionUnsuccess.RequestedConfigura
tionNotSupport
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of radio links successfully deleted on an RNSAP point of view.
B-Collection
CC
NORTEL CUM type counter
C-Condition
Nortel Confidential
213
(Event)
D-Result
(Unit)
E-Type
VS.IurDrncRadioLinkDeletionSuccess
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of radio links successfully prepared for reconfiguration, which are screened by DL Access Stratum configuration.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IurDrncRadioLinkReconfigurationPrepareSuccess.
F-Object Instance
(Location)
FDDCell / DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
214
This measurement provides the number of radio links unsuccessfully prepared for reconfiguration, which are screened by cause of
reconfiguration preparation failure.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IurDrncRadioLinkReconfigurationPrepareUnsuccess.Uns
pecified
VS.IurDrncRadioLinkReconfigurationPrepareUnsuccess.NoR
adioResource
VS.IurDrncRadioLinkReconfigurationPrepareUnsuccess.Nba
pRefusal
VS.IurDrncRadioLinkReconfigurationPrepareUnsuccess.Req
uestedConfigurationNotSupport
F-Object Instance
(Location)
FDDCell
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
Nortel Confidential
215
D-Result
(Unit)
E-Type
VS.IurDrncRadioLinkReconfigurationCancelSuccess.
F-Object Instance
(Location)
FDDCell / DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IurDrncRadioLinkReconfigurationCommitSuccess.
F-Object Instance
(Location)
FDDCell / DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
216
Nortel Confidential
217
Counter name
#1311
VS.IurSccpCnxSuccess.
#1312
VS.IurSccpCnxUnsuccess.
#1315
VS.IurAvgNbrInitSccpCnx.Avg
VS.IurAvgNbrInitSccpCnx.Max
VS.IurAvgNbrInitSccpCnx.Min
#1316
VS.IurAvgNbrTermSccpCnx.Avg
VS.IurAvgNbrTermSccpCnx.Max
VS.IurAvgNbrTermSccpCnx.Min
#1317
VS.IurEmittedSccpAbnormalDisconnects.
#1318
VS.IurReceivedSccpAbnormalDisconnects
This measurement provides the number of successful SCCP connections at the Iur interface for each neighboring RNC of a considered RNC.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IurSccpCnxSuccess.EstablishedAsServingRNC
VS.IurSccpCnxSuccess.EstablishedAsDriftRNC
F-Object Instance
(Location)
Neighboring RNC
G-Switching
Nortel Confidential
218
H-3GPP Compliance
I-Available Release
V2
This measurement provides the number of failed SCCP connections at the Iur interface for each neighboring RNC of a given
RNC.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
Subcounter #1 => Refusal of distant RNC request (by the local RNC)
VS.IurSccpCnxUnsuccess.FailConnectionReqByLocalIRncO
nIur
VS.IurSccpCnxUnsuccess.FailConnectionReqByNeighbourin
gIRncOnIur
F-Object Instance
(Location)
Neighboring RNC
G-Switching
H-3GPP Compliance
I-Available Release
V2
This measurement provides the average number of SCCP connections on Iur initiated toward a neighboring RNC during the reporting period.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
Nortel Confidential
219
E-Type
VS.IurAvgNbrInitSccpCnx.Avg
F-Object Instance
(Location)
Neighboring RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the maximum number of SCCP connections on Iur initiated toward a neighboring RNC during the reporting period.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IurAvgNbrInitSccpCnx.Max
F-Object Instance
(Location)
Neighboring RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the minimum number of SCCP connections on Iur initiated toward a neighboring RNC during the reporting period.
B-Collection
SI
NORTEL LOAD type counter
Nortel Confidential
220
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IurAvgNbrInitSccpCnx.Min
F-Object Instance
(Location)
Neighboring RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the average number of SCCP connections on Iur terminated from a neighboring RNC during the reporting period.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IurAvgNbrTermSccpCnx.Avg
F-Object Instance
(Location)
Neighboring RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the maximum number of SCCP connections on Iur terminated from a neighboring RNC during the re-
Nortel Confidential
221
porting period.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IurAvgNbrTermSccpCnx.Max
F-Object Instance
(Location)
Neighboring RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the minimum number of SCCP connections on Iur terminated from a neighboring RNC during the reporting period.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IurAvgNbrTermSccpCnx.Min
F-Object Instance
(Location)
Neighboring RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
222
This measurement provides the number of emitted SCCP abnormal disconnections on Iur.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
Screening is as follows:
E-Type
VS.IurEmittedSccpAbnormalDisconnects.EndUserOriginated
VS.IurEmittedSccpAbnormalDisconnects.EndUserCongestio
n
VS.IurEmittedSccpAbnormalDisconnects.EndUserFailure
F-Object Instance
(Location)
Neighboring RNC
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of received SCCP abnormal disconnections on Iur.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IurReceivedSccpAbnormalDisconnects
F-Object Instance
(Location)
Neighboring RNC
G-Switching
H-3GPP Compliance
Nortel Confidential
I-Available Release
223
V3
Nortel Confidential
224
Counter name
#1401
VS.DedicatedUplinkKbytesRlcSrb.
#1402
VS.DedicatedDownlinkKbytesRlcSrb.
#1403
VS.DedicatedUplinkPduRlcSrb.
#1404
VS.DedicatedDownlinkPduRlcSrb.
#1405
VS.DedicatedUplinkSduRlcSrb.
#1406
VS.DedicatedDownlinkSduRlcSrb.
#1407
VS.DedicatedUplinkMissingPduRlcSrb.
#1408
VS.DedicatedDownlinkDiscardSduRlcSrb.
#1409
VS.DedicatedDownlinkPaddingSduRlcSrb.
#1410
VS.DedicatedUplinkKbytesRlcCsData.
#1411
VS.DedicatedDownlinkKbytesRlcCsData.
#1412
VS.DedicatedUplinkPduRlcCsData.
#1413
VS.DedicatedDownlinkPduRlcCsData.
#1414
VS.DedicatedUplinkSduRlcCsData.
#1415
VS.DedicatedDownlinkSduRlcCsData.
#1416
VS.DedicatedUplinkMissingPduRlcCsData.
#1417
VS.DedicatedDownlinkDiscardSduRlcCsData.
#1418
VS.DedicatedDownlinkPaddingSduRlcCsData.
#1419
VS.DedicatedUplinkKbytesRlcPs.
#1420
VS.DedicatedDownlinkKbytesRlcPs.
#1421
VS.DedicatedUplinkPduRlcPs.
#1422
VS.DedicatedDownlinkPduRlcPs.
#1423
VS.DedicatedUplinkSduRlcPs.
#1424
VS.DedicatedDownlinkSduRlcPs.
#1425
VS.DedicatedUplinkMissingPduRlcPs.
#1426
VS.DedicatedDownlinkDiscardSduRlcPs.
#1427
VS.DedicatedDownlinkPaddingSduRlcPs.
#1429
VS.DedicatedUplinkBadPdusCs.
#1430
VS.DedicatedUplinkBadPdusPs.
#1431
VS.DedicatedUplinkVoiceABitsGoodFrames.
Nortel Confidential
225
Counter name
#1432
VS.DedicatedUplinkVoiceABitsBadFrames.
#1433
VS.DedicatedDownlinkActivityRlcCs.
#1434
VS.DedicatedUplinkActivityRlcCs.
#1435
#1436
VS.DedicatedUplinkActivityRlcPs.
This measurement provides the total count of uplink RLC payload on dedicated channels containing Signalling Radio Bearer
data.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedUplinkKbytesRlcSrb.
F-Object Instance
(Location)
RNC/UlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Nortel Confidential
D-Result
(Unit)
226
E-Type
VS.DedicatedDownlinkKbytesRlcSrb.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedUplinkPduRlcSrb.
F-Object Instance
(Location)
RNC/UlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
227
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedDownlinkPduRlcSrb.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedUplinkSduRlcSrb.
F-Object Instance
(Location)
RNC/UlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
228
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedDownlinkSduRlcSrb.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedUplinkMissingPduRlcSrb.
Nortel Confidential
229
F-Object Instance
(Location)
RNC/UlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Each time a SDU containing SRB data is discarded without being sent on an downlink dedicated channel.
D-Result
(Unit)
E-Type
VS.DedicatedDownlinkDiscardSduRlcSrb.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
230
Screening is as follows:
Subcounter # i => DlAccessStratumConf#i for i = 0 to 20
Refer to Downlink Access Stratum Configuration.
E-Type
VS.DedicatedDownlinkPaddingSduRlcSrb.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
This measurement provides the total count of uplink RLC payload on dedicated channels containing Circuit Switched Radio
Bearer data.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedUplinkKbytesRlcCsData.
F-Object Instance
(Location)
RNC/UlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
231
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedDownlinkKbytesRlcCsData.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedUplinkPduRlcCsData.
Nortel Confidential
232
F-Object Instance
(Location)
RNC/UlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedDownlinkPduRlcCsData.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
Nortel Confidential
233
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedUplinkSduRlcCsData.
F-Object Instance
(Location)
RNC/UlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedDownlinkSduRlcCsData.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
Nortel Confidential
I-Available Release
234
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedUplinkMissingPduRlcCsData.
F-Object Instance
(Location)
RNC/UlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Each time a SDU containing Circuit Switched RB data is discarded without being sent on an downlink dedicated channel
D-Result
(Unit)
Nortel Confidential
235
VS.DedicatedDownlinkDiscardSduRlcCsData.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedDownlinkPaddingSduRlcCsData.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
236
This measurement provides the total count of uplink RLC payload on dedicated channels containing Packet Switched data.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedUplinkKbytesRlcPs.
F-Object Instance
(Location)
RNC/UlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
237
Note: Only results corresponding to Access Stratum configurations including a CS RB (2, 4, 6, 7, 8, 9, 10, 11, 12,
15, 16, 17, 18, 19, 20) are meaningful; otherwise, the others are always zeros.
E-Type
VS.DedicatedDownlinkKbytesRlcPs.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedUplinkPduRlcPs.
F-Object Instance
(Location)
RNC/UlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
238
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedDownlinkPduRlcPs.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedUplinkSduRlcPs.
Nortel Confidential
239
F-Object Instance
(Location)
RNC/UlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedDownlinkSduRlcPs.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
Nortel Confidential
240
(Event)
Switched RB data on an uplink dedicated channel with a sequence number greater than the sequence number of the last
PDU received + 1
D-Result
(Unit)
E-Type
VS.DedicatedUplinkMissingPduRlcPs.
F-Object Instance
(Location)
RNC/UlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Each time a SDU containing Packet Switched RB data is discarded without being sent on an downlink dedicated channel.
D-Result
(Unit)
E-Type
VS.DedicatedDownlinkDiscardSduRlcPs.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
Nortel Confidential
241
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedDownlinkPaddingSduRlcPs.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
Nortel Confidential
(Unit)
242
Access Stratum configuration. Only results corresponding to Uplink Access Stratum Configurations that include a CS RB are
meaningful. Others are always 0.
Refer to Uplink Access Stratum Configuration.
Screening is as follows:
E-Type
VS.DedicatedUplinkBadPdusCs.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V4
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedUplinkBadPdusPs.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V4
Nortel Confidential
243
Traffic)
A-Description
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedUplinkVoiceABitsGoodFrames.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V4
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Nortel Confidential
D-Result
(Unit)
244
E-Type
VS.DedicatedUplinkVoiceABitsBadFrames.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V4
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedDownlinkActivityRlcCs.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V4
Nortel Confidential
245
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedUplinkActivityRlcCs.
F-Object Instance
(Location)
RNC/UlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V4
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedDownlinkActivityRlcPs.
F-Object Instance
(Location)
RNC/DlAsConf
G-Switching
H-3GPP Compliance
Nortel Confidential
246
NORTEL # 1435
I-Available Release
V4
This measurement provides the cumulated traffic activity in uplink of PS RAB during the observation period at MAC level.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.DedicatedUplinkActivityRlcPs.
F-Object Instance
(Location)
RNC/UlAsConf
G-Switching
H-3GPP Compliance
I-Available Release
V4
Nortel Confidential
247
Counter name
VS.E3PrLoadCnTmu.xxx.Cum
VS.E3PrLoadCnTmu.xxx.NbEvt
VS.E3PrLoadCnTmu.xxx.Avg
VS.E3PrLoadCnTmu.xxx.Max
VS.E3PrLoadCnTmu.xxx.Min
B-Collection
SI
NORTEL LOAD type counter ("Cumulating value" part)
C-Condition
(Event)
A sampling event is generated according to a 100 ms sampling period. Sample loads of TMU processor values are cumulated. The cumulated value is calculated at the end of the
reporting period.
It is expressed as a percentage (the value 100 expresses a
100% load)
D-Result
(Unit)
E-Type
VS.E3PrLoadCnTmu.Sbc.Cum
VS.E3PrLoadCnTmu.Tm.Cum
VS.E3PrLoadCnTmu.Pmc.Cum
F-Object Instance
(Location)
TMU
G-Switching
H-3GPP Compliance
Nortel Confidential
I-Available Release
248
V2
B-Collection
SI
NORTEL LOAD type counter ("Number of events" part)
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.E3PrLoadCnTmu.Sbc.NbEvt
VS.E3PrLoadCnTmu.Tm.NbEvt
VS.E3PrLoadCnTmu.Pmc.NbEvt
F-Object Instance
(Location)
TMU
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
E-Type
249
VS.E3PrLoadCnTmu.Sbc.Avg
VS.E3PrLoadCnTmu.Tm.Avg
VS.E3PrLoadCnTmu.Pmc.Avg
F-Object Instance
(Location)
TMU
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
The maximum processor load of TMU processors is reassessed at each 100 ms sampling period during the reporting period.
It is expressed as a percentage (the value 100 expresses a
100% load)
D-Result
(Unit)
E-Type
VS.E3PrLoadCnTmu.Sbc.Max
VS.E3PrLoadCnTmu.Tm.Max
VS.E3PrLoadCnTmu.Pmc.Max
F-Object Instance
(Location)
TMU
G-Switching
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
250
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
The minimum processor load of TMU processors is reassessed at each 100 ms sampling period during the reporting period.
It is expressed as a percentage (the value 100 expresses a
100% load)
D-Result
(Unit)
E-Type
VS.E3PrLoadCnTmu.Sbc.Min
VS.E3PrLoadCnTmu.Tm.Min
VS.E3PrLoadCnTmu.Pmc.Min
F-Object Instance
(Location)
TMU
G-Switching
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
251
"Radio counters"
"RACH Counters"
"EEC counters"
"HSSPC counters"
"BTS IP counters"
Nortel Confidential
252
Counter name
#10001
VS.PcmLos
#10002
VS.PcmAis
#10003
VS.PcmLfa
#10004
VS.PcmFe
#10005
VS.PcmCrc
#10006
VS.PcmRai
#10007
VS.PcmFas
#10008
VS.PcmEbits
#10009
VS.PcmBpv
#10010
VS.PcmSlip
#10011
VS.PcmEs
#10012
VS.PcmSes
#10013
VS.PcmBbe
#10014
VS.PcmUas
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.PcmLos
F-Object Instance
(Location)
PCM
G-Switching
H-3GPP Compliance
Nortel Confidential
253
NORTEL # 10001
I-AvailableRelease
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Alarm Indication Signal sent by the remote equipment indicating that a transmission fault is located either at the remote
equipment or upstream of the transmitting equipment.
D-Result
(Unit)
E-Type
VS.PcmAis
F-Object Instance
(Location)
PCM
G-Switching
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.PcmLfa
F-Object Instance
(Location)
PCM
G-Switching
H-3GPP Compliance
I-AvailableRelease
V2
Nortel Confidential
254
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.PcmFe
F-Object Instance
(Location)
PCM
G-Switching
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.PcmCrc
F-Object Instance
(Location)
PCM
G-Switching
H-3GPP Compliance
I-AvailableRelease
V2
Nortel Confidential
255
to RAI alarm.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.PcmRai
F-Object Instance
(Location)
PCM
G-Switching
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.PcmFas
F-Object Instance
(Location)
PCM
G-Switching
H-3GPP Compliance
I-AvailableRelease
V2
Nortel Confidential
256
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.PcmEbits
F-Object Instance
(Location)
PCM
G-Switching
H-3GPP Compliance
I-AvailableRelease
V2
This measurement provides the number of consecutive bipolar violations, of the same polarity, detected on the receiving
line per second.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.PcmBpv
F-Object Instance
(Location)
PCM
G-Switching
H-3GPP Compliance
I-AvailableRelease
V2
Nortel Confidential
257
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.PcmSlip
F-Object Instance
(Location)
PCM
G-Switching
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.PcmEs
F-Object Instance
(Location)
PCM
G-Switching
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
CC
NORTEL CUM type counter
Nortel Confidential
258
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.PcmSes
F-Object Instance
(Location)
PCM
G-Switching
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.PcmBbe
F-Object Instance
(Location)
PCM
G-Switching
H-3GPP Compliance
I-AvailableRelease
V2
This measurement provides the number of Severely UnAvailable Second(s) during the last supervision period.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
Nortel Confidential
259
(Unit)
Screening = NO
E-Type
VS.PcmUas
F-Object Instance
(Location)
PCM
G-Switching
H-3GPP Compliance
I-AvailableRelease
V2
Nortel Confidential
260
Counter name
#10101
VS.AAL2NbReceivedCell
#10102
VS.AAL2NbLostCPS
#10103
VS.AAL2NbSTFParityErr
#10104
VS.AAL2NbSequenceNumberErr
#10105
VS.AAL2NbCPSHecErr
#10106
VS.AAL2NbCPSLengthErr
#10107
VS.AAL2NbCpsLengthMismatch
#10108
VS.AAL2NbCpsInvalidCIDErr
#10109
VS.AAL2NbOSFBiggerThan47
#10110
VS.AAL5NbReceivedCell
#10111
VS.AAL5NbAbortErr
#10112
VS.AAL5NbLengthErr
#10113
VS.AAL5NbCrcFrameErr
#10114
VS.AAL5NbInvalidSize
#10115
VS.AAL2NbSentCell
#10116
VS.AAL5NbSentCell
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AAL2NbReceivedCell
F-Object Instance
AtmVcc
Nortel Confidential
261
(Location)
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AAL2NbLostCPS
F-Object Instance
(Location)
AtmVcc
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AAL2NbCpsInvalidCIDErr
F-Object Instance
(Location)
AtmVcc
G-Switching
H-3GPP Compliance
Nortel Confidential
262
NORTEL # 10103
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AAL2NbSequenceNumberErr
F-Object Instance
(Location)
AtmVcc
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AAL2NbCPSHecErr
F-Object Instance
(Location)
AtmVcc
G-Switching
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
263
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AAL2NbCPSLengthErr
F-Object Instance
(Location)
AtmVcc
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
The counter is increased upon detection of an LI field content in CPS packets different from the OSF field content in
CPS PDUs.
D-Result
(Unit)
E-Type
VS.AAL2NbCpsLengthMismatch
F-Object Instance
(Location)
AtmVcc
G-Switching
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
264
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AAL2NbCPSInvalidCIDErr
F-Object Instance
(Location)
AtmVcc
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AAL2NbOSFBiggerThan47
F-Object Instance
(Location)
AtmVcc
G-Switching
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
265
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AAL5NbReceivedCell
F-Object Instance
(Location)
AtmVcc
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AAL5NbAbortErr
F-Object Instance
(Location)
AtmVcc
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
Nortel Confidential
266
(Event)
D-Result
(Unit)
E-Type
VS.AAL5NbLengthErr
F-Object Instance
(Location)
AtmVcc
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AAL5NbCrcFrameErr
F-Object Instance
(Location)
AtmVcc
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
The counter is increased upon detection of a frame size bigger than the maximum frame size.
D-Result
(Unit)
Nortel Confidential
267
E-Type
VS.AAL5NbInvalidSize
F-Object Instance
(Location)
AtmVcc
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AAL2NbSentCell
F-Object Instance
(Location)
AtmVcc
G-Switching
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.AAL5NbSentCell
F-Object Instance
(Location)
AtmVcc
Nortel Confidential
268
G-Switching
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
269
Radio counters
This section describes all the Radio observation counters for RAN V4.0 of the UMTS V4.0 system
release.
Each Radio counter is applicable either to a managed BTSCell object instance or to a physical Power
Amplifier component instance.
The following table lists all the Radio counters.
Table 365 Radio counters
Nortel counter number
Counter name
#10201
VS.RadioWBandRxMainPwr.Cum
VS.RadioWBandRxMainPwr.NbEvt
VS.RadioWBandRxMainPwr.Avg
VS.RadioWBandRxMainPwr.Min
VS.RadioWBandRxMainPwr.Max
#10202
VS.RadioWBandRxDivPwr.Cum
VS.RadioWBandRxDivPwr.NbEvt
VS.RadioWBandRxDivPwr.Avg
VS.RadioWBandRxDivPwr.Min
VS.RadioWBandRxDivPwr.Max
#10203
VS.RadioTxCarrierPwr.Cum
VS.RadioTxCarrierPwr.NbEvt
VS.RadioTxCarrierPwr.Avg
VS.RadioTxCarrierPwr.Min
VS.RadioTxCarrierPwr.Max
#10204
VS.MCPAPwr.Cum
VS.MCPAPwr.NbEvt
VS.MCPAPwr.Avg
VS.MCPAPwr.Min
VS.MCPAPwr.Max
B-Collection
SI
NORTEL LOAD type counter ("Cumulating value" part)
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
270
E-Type
VS.RadioWBandRxMainPwr.Cum
F-Object Instance
(Location)
BTSCell
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
This measurement provides the number of the wide-band received power on the main antenna for each cell (per sector
and per frequency).
B-Collection
SI
NORTEL LOAD type counter ("Number of events" part)
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioWBandRxMainPwr.NbEvt
F-Object Instance
(Location)
BTSCell
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioWBandRxMainPwr.Avg
F-Object Instance
BTSCell
Nortel Confidential
271
(Location)
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioWBandRxMainPwr.Min
F-Object Instance
(Location)
BTSCell
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioWBandRxMainPwr.Max
F-Object Instance
(Location)
BTSCell
G-Switching
N.A.
Nortel Confidential
272
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
SI
NORTEL LOAD type counter ("Cumulating value" part)
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioWBandRxDivPwr.Cum
F-Object Instance
(Location)
BTSCell
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
This measurement provides the number of the wide-band received power on the diversity antenna for each cell (per sector
and per frequency).
B-Collection
SI
NORTEL LOAD type counter ("Number of events" part)
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioWBandRxDivPwr.NbEvt
F-Object Instance
(Location)
BTSCell
G-Switching
N.A.
H-3GPP Compliance
Nortel Confidential
I-AvailableRelease
273
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioWBandRxDivPwr.Avg
F-Object Instance
(Location)
BTSCell
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioWBandRxDivPwr.Min
F-Object Instance
(Location)
BTSCell
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
Nortel Confidential
274
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioWBandRxDivPwr.Max
F-Object Instance
(Location)
BTSCell
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
SI
NORTEL LOAD type counter ("Cumulating value" part)
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioTxCarrierPwr.Cum
F-Object Instance
(Location)
BTSCell
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
Nortel Confidential
275
This measurement provides the number of the total transmitted power for each cell (per sector and per frequency).
B-Collection
SI
NORTEL LOAD type counter ("Cumulating value" part)
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioTxCarrierPwr.NbEvt
F-Object Instance
(Location)
BTSCell
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioTxCarrierPwr.Avg
F-Object Instance
(Location)
BTSCell
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
Nortel Confidential
276
This minimum value is re-assessed at each 100 ms period during the collection period.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioTxCarrierPwr.Min
F-Object Instance
(Location)
BTSCell
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RadioTxCarrierPwr.Max
F-Object Instance
(Location)
BTSCell
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
Nortel Confidential
277
B-Collection
SI
NORTEL LOAD type counter ("Cumulating value" part)
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.MCPAPwr.Cum
F-Object Instance
(Location)
PassiveComponent/PA
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
This measurement provides the number of the total transmitted power by the Power Amplifier.
B-Collection
SI
NORTEL LOAD type counter ("Number of events" part)
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.MCPAPwr.NbEvt
F-Object Instance
(Location)
PassiveComponent/PA
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
Nortel Confidential
278
(Event)
D-Result
(Unit)
E-Type
VS.MCPAPwr.Avg
F-Object Instance
(Location)
PassiveComponent/PA
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.MCPAPwr.Min
F-Object Instance
(Location)
PassiveComponent/PA
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
Nortel Confidential
279
(Event)
D-Result
(Unit)
E-Type
VS.MCPAPwr.Max
F-Object Instance
(Location)
PassiveComponent/PA
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
Nortel Confidential
280
Counter name
#10301
VS.CEMUsed.Cum
VS.CEMUsed.NbEvt
VS.CEMUsed.Avg
VS.CEMUsed.Min
VS.CEMUsed.Max
#10302
VS.CEMAllocFail
B-Collection
SI
NORTEL LOAD type counter ("Cumulating value" part)
C-Condition
(Event)
A sampling event is generated according to a sampling period. Sampled CEM capacity used values are cumulated.The
value is calculated at the end of the reporting period.
It is expressed as a percentage (the value 100 expresses a
100% load).
D-Result
(Unit)
E-Type
VS.CEMUsed.Cum
F-Object Instance
(Location)
BTSEquipment
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
281
used.
B-Collection
SI
NORTEL LOAD type counter ("Number of events" part)
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CEMUsed.NbEvt
F-Object Instance
(Location)
BTSEquipment
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
A sampling event is generated according to a sampling period. Sampled CEM capacity used values are cumulated.The
average value is calculated at the end of the reporting period.
It is expressed as a percentage (the value 100 expresses a
100% load).
D-Result
(Unit)
E-Type
VS.CEMUsed.Avg
F-Object Instance
(Location)
BTSEquipment
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
282
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CEMUsed.Min
F-Object Instance
(Location)
BTSEquipment
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CEMUsed.Max
F-Object Instance
(Location)
BTSEquipment
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V2
This measurement provides the percentage of times allocation of CEM resources that failed due to unavailability of
CEM resources.
Nortel Confidential
283
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CEMAllocFail
F-Object Instance
(Location)
BTSEquipment
G-Switching
N.A.
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
284
RACH Counters
This section describes all the RACH observation counters for RAN V4.0 of the UMTS V4.0 system
release.
Each RACH counter is applicable to a managed BTSCell object instance.
The following table lists all the RACH counters.
Table 393 RACH Counters
Nortel counter number
Counter name
#10303
VS.RachNack.Cum
VS.RachNack.NbEvt
VS.RachNack.Avg
VS.RachNack.Max
VS.RachNack.Min
#10304
VS.RachNackSquare
#10305
VS.RachAck
#10306
VS.RachAckSquare
This measurement provides the number of refused Random accesses (RACH NACK) sent in a cell during a reporting period.
B-Collection
DER
NORTEL VAL type counter ("Cumulating value" part)
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RachNack.Cum
F-Object Instance
(Location)
BTSCell
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
285
B-Collection
DER
NORTEL VAL type counter ("Number of events" part)
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RachNack.NbEvt
F-Object Instance
(Location)
BTSCell
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
DER
NORTEL VAL type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RachNack.Avg
F-Object Instance
(Location)
BTSCell
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
This measurement provides the maximum number of TTI windows during a reporting period.
B-Collection
DER
NORTEL VAL type counter
C-Condition
(Event)
Nortel Confidential
286
D-Result
(Unit)
E-Type
VS.RachNack.Max
F-Object Instance
(Location)
BTSCell
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
This measurement provides the minimum number of TTI windows during a reporting period.
B-Collection
DER
NORTEL VAL type counter
C-Condition
Incremented by the
number of RACH
NACK at the end of
each TTI window(Event)
D-Result
(Unit)
E-Type
VS.RachNack.Min
F-Object Instance
(Location)
BTSCell
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
Nortel Confidential
287
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RachNackSquare
F-Object Instance
(Location)
BTSCell
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RachAck
F-Object Instance
(Location)
BTSCell
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
Nortel Confidential
288
D-Result
(Unit)
E-Type
VS.RachAckSquare
F-Object Instance
(Location)
BTSCell
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
289
EEC counters
This section describes all the Enhanced Error Collector (EEC) counters for RAN V4.0 of the UMTS
V4.0 system release.
Each EEC counter is applicable to a managed Board (CCM/CEM/TRM) object instance.
The following table lists all the RACH counters.
Table 402 EEC counters
Nortel counter number
Counter name
#10401
VS.longestTaskLock
#10402
VS.wdgPcfyItvl
#10403
VS.CpuLoad.Cum
VS.CpuLoad.NbEvt
VS.CpuLoad.Avg
VS.CpuLoad.Max
VS.CpuLoad.Min
#10404
VS.IsrNestingDepth
#10405
VS.TotalisrCount
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.longestTaskLock
F-Object Instance
(Location)
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
Nortel Confidential
290
val
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.wdgPcfyItvl
F-Object Instance
(Location)
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
SI
NORTEL LOAD type counter ("Cumulating value" part)
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CpuLoad.Cum
F-Object Instance
(Location)
TRM/CCM/CEM module
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
SI
NORTEL LOAD type counter ("Number of events" part)
Nortel Confidential
291
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CpuLoad.NbEvt
F-Object Instance
(Location)
TRM/CCM/CEM module
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CpuLoad.Avg
F-Object Instance
(Location)
TRM/CCM/CEM module
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
Nortel Confidential
292
D-Result
(Unit)
E-Type
VS.CpuLoad.Max
F-Object Instance
(Location)
TRM/CCM/CEM module
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CpuLoad.Min
F-Object Instance
(Location)
TRM/CCM/CEM module
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
On receipt of ISR
D-Result
(Unit)
Nortel Confidential
293
E-Type
VS.IsrNestingDepth
F-Object Instance
(Location)
TRM/CCM/CEM board
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.TotalisrCount
F-Object Instance
(Location)
TRM/CCM/CEM board
G-Switching
N.A.
H-3GPP Compliance
I-AvailableRelease
V2
Nortel Confidential
294
HSSPC counters
The HSSPC counters are only for internal use and are not detailed.
The following table lists all the HSSPC counters.
Table 412 HSSPC counters
Nortel counter number
Counter name
#10501
Tx_A_link_parity_errors
#10502
Tx_A_link_loss_of_even_second_errors
#10503
Tx_A_link_fifo_overflow_underrun_errors
#10504
Tx_A_link_atm_cell_buffer_overflow_errors
#10505
Tx_A_atm_cells_number
#10506
Tx_A_flow_control_transitions
#10507
Rx_A_link_parity errors
#10508
Rx_A_link_loss_of_even_second_errors
#10509
Rx_A_link_loss_of_frame_errors
#10510
Rx_A_link_fifo_overflow_underrun_errors
#10511
Rx_A_link_atm_cell_buffer_overflow_errors
#10512
Rx_A_link_control_line_change_of_state
#10513
Rx_A_link_8b_10b_errors
#10514
Rx_A_atm_cells_number
#10515
Rx_A_flow_control_transitions
#10516
Link_A_even_second_delay
#10517
Tx_B_link_parity_errors
#10518
Tx_B_link_loss_of_even_second_errors
#10519
Tx_B_link_fifo_overflow_underrun_errors
#10520
Tx_B_link_atm_cell_buffer_overflow_errors
#10521
Tx_B_atm_cells_number
#10522
Tx_B_flow_control_transitions
#10523
Rx_B_link_parity errors
#10524
Rx_B_link_loss_of_even_second_errors
#10525
Rx_B_link_loss_of_frame_errors
#10526
Rx_B_link_fifo_overflow_underrun_errors
#10527
Rx_B_link_atm_cell_buffer_overflow_errors
#10528
Rx_B_link_control_line_change_of_state
#10529
Rx_B_link_8b_10b_errors
#10530
Rx_B_atm_cells_number
#10531
Rx_B_flow_control_transitions
Nortel Confidential
295
Counter name
#10532
Link_B_even_second_delay
#10533
I2C_read_errors
#10534
I2C_write_erros
Nortel Confidential
296
Counter name
#10601
VS.ImaGroupUnavailSecs
#10602
VS.ImaGroupNeNumFailures
#10603
VS.ImaLinkImaViolations
#10604
VS.ImaLinkNeSevErroredSecs
#10605
VS.ImaLinkFeSevErroredSecs
#10606
VS.ImaLinkNeUnavailSecs
#10607
VS.ImaLinkFeUnavailSecs
#10608
VS.ImaLinkNeTxUnusableSecs
#10609
VS.ImaLinkNeRxUnusableSecs
#10610
VS.ImaLinkFeTxUnusableSecs
#10611
VS.ImaLinkFeRxUnusableSecs
#10612
VS.ImaLinkNeTxNumFailures
#10613
VS.ImaLinkNeRxNumFailures
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.ImaGroupUnavailSecs
F-Object Instance
(Location)
IMAGroup
G-Switching
N/A
H-3GPP Compliance
Nortel Confidential
I-Available Release
297
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.ImaGroupNeNumFailures
F-Object Instance
(Location)
IMAGroup
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of ICP violations: number of errored, invalid or missing ICP cells, except during SESIMA (Severely Errored Seconds) or UAS-IMA (Unavailable Seconds) conditions. This measurement will not exclude faulty ICP
cells during SES-IMA and UAS-IMA conditions.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.ImaLinkImaViolations
F-Object Instance
(Location)
PCMLink
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
298
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
N/A
D-Result
(Unit)
E-Type
VS.ImaLinkNeSevErroredSecs
F-Object Instance
(Location)
PCMLink
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.ImaLinkFeSevErroredSecs
F-Object Instance
(Location)
PCMLink
G-Switching
N/A
H-3GPP Compliance
Nortel Confidential
299
NORTEL # 10605
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.ImaLinkNeUnavailSecs
F-Object Instance
(Location)
PCMLink
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.ImaLinkFeUnavailSecs
F-Object Instance
(Location)
PCMLink
G-Switching
N/A
H-3GPP Compliance
Nortel Confidential
300
IMA-FE
NORTEL # 10607
I-Available Release
V3
This measurement provides the number of Tx Unusable seconds at the near-end Tx LSM (Link State Machine)
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
N/A
D-Result
(Unit)
E-Type
VS.ImaLinkNeTxUnusableSecs
F-Object Instance
(Location)
PCMLink
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of Rx Unusable seconds at the near-end Rx LSM (Link State Machine).
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
N/A
D-Result
(Unit)
E-Type
VS.ImaLinkNeRxUnusableSecs
F-Object Instance
(Location)
PCMLink
G-Switching
N/A
H-3GPP Compliance
Nortel Confidential
I-Available Release
301
V3
This measurement provides the number of Tx Unusable seconds at the far-end Tx LSM (Link State Machine).
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
N/A
D-Result
(Unit)
E-Type
VS.ImaLinkFeTxUnusableSecs
F-Object Instance
(Location)
PCMLink
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of Rx Unusable seconds at the far-end Rx LSM (Link State Machine).
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
N/A
D-Result
(Unit)
E-Type
VS.ImaLinkFeRxUnusableSecs
F-Object Instance
(Location)
PCMLink
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
302
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.ImaLinkNeTxNumFailures
F-Object Instance
(Location)
PCMLink
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
This measurement provides the number of times a near-end receive failure alarm condition has been entered on this link (for
example LIF, LODS, RFI-IMA, Mis-Connected or some form of
implementation specific receive fault). This counter will not take
into account the fault Rx-Mis-Connected (for example, Rx link is
not connected to the same Far End IMA unit as the other Rx link
in the group).
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.ImaLinkNeRxNumFailures
F-Object Instance
(Location)
PCMLink
G-Switching
N/A
Nortel Confidential
303
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
304
BTS IP counters
This section describes all the BTS IP observation counters for RAN V4.0 of the UMTS V4.0 system
release.
Each IP observation counter is applicable to a managed IPInterface object instance.
The following table lists all the BTS IP counters.
Table 427 BTS IP counters
Nortel counter number
Counter name
#10701
VS.IfInOctets
#10702
VS.IfInUcastPkts
#10703
VS.IfInNUcastPkts
#10704
VS.IfInDiscards
#10705
VS.IfInErrors
#10706
VS.IfInUnknownProtos
#10707
VS.ifOutOctets
#10708
VS.IfOutUcastPkts
#10709
VS.IfOutNUcastPkts
#10710
VS.IfOutDiscards
#10711
VS.IfOutErrors
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IfInOctets
F-Object Instance
(Location)
IPInterface
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
305
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IfInUcastPkts
F-Object Instance
(Location)
IPInterface
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IfInNUcastPkts
F-Object Instance
(Location)
IPInterface
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
306
detected to prevent their being delivered to a higher-layer protocol. One possible reason for discarding such a packet could be
to free up buffer space.
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IfInDiscards
F-Object Instance
(Location)
IPInterface
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IfInErrors
F-Object Instance
(Location)
IPInterface
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
307
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IfInUnknownProtos
F-Object Instance
(Location)
IPInterface
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
This measurement provides the total number of octets transmitted out of the interface, including framing characters
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.ifOutOctets
F-Object Instance
(Location)
IPInterface
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
Nortel Confidential
308
(Event)
D-Result
(Unit)
E-Type
VS.IfOutUcastPkts
F-Object Instance
(Location)
IPInterface
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IfOutNUcastPkts
F-Object Instance
(Location)
IPInterface
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
Nortel Confidential
309
(Event)
D-Result
(Unit)
E-Type
VS.IfOutDiscards
F-Object Instance
(Location)
IPInterface
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.IfOutErrors
F-Object Instance
(Location)
IPInterface
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V3
Nortel Confidential
310
Nortel Confidential
311
Counter name
# 20001
VS.ProvRate
# 20002
VS.ActualRate
# 20003
VS.TxUtilization
# 20004
VS.RxUtilization
# 20005
VS.TxMaxCellRate
# 20006
VS.TxMinCellRate
# 20007
VS.TxAvgCellRate
# 20008
VS.RxMaxCellRate
# 20009
VS.RxMinCellRate
# 20010
VS.RxAvgCellRate
# 20011
VS.TxMaxCellRateClp
# 20012
VS.TxMinCellRateClp
# 20013
VS.TxAvgCellRateClp
# 20014
VS.RxMaxCellRateClp
# 20015
VS.RxMinCellRateClp
# 20016
VS.RxAvgCellRateClp
# 20017
VS.TxCellDiscards
# 20018
VS.RxCellDiscards
# 20019
VS.TxFrameDiscards
# 20020
VS.RxFrameDiscards
# 20021
VS.TxCellDiscardsClp
# 20022
VS.RxCellDiscardsClp
# 20023
VS.TxFrameDiscardsClp
# 20024
VS.RxFrameDiscardsClp
# 20025
VS.TxMaxCellRate.
# 20026
VS.TxMinCellRate.
# 20027
VS.TxAvgCellRate.
# 20028
VS.RxMaxCellRate.
# 20029
VS.RxMinCellRate.
# 20030
VS.RxAvgCellRate.
Nortel Confidential
312
Counter name
# 20031
VS.TxMaxCellRateClp.
# 20032
VS.TxMinCellRateClp.
# 20033
VS.TxAvgCellRateClp.
# 20034
VS.RxMaxCellRateClp.
# 20035
VS.RxMinCellRateClp.
# 20036
VS.RxAvgCellRateClp.
# 20037
VS.TxCellDiscards.
# 20038
VS.RxCellDiscards.
# 20039
VS.TxFrameDiscards.
# 20040
VS.RxFrameDiscards.
# 20041
VS.TxCellDiscardsClp.
# 20042
VS.RxCellDiscardsClp.
# 20043
VS.TxFrameDiscardsClp.
# 20044
VS.RxFrameDiscardsClp.
B-Collection
DER
NORTEL VALUE type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.ProvRate
F-Object Instance
(Location)
AtmPort
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
313
zero when the link (or IMA group) is done for the entire collection interval.
the average bandwidth when the link goes down during the
collection interval.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.ActualRate
F-Object Instance
(Location)
AtmPort
G-Switching
N/A
H-3GPP Compliance
I-Available Release
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.TxUtilization
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
314
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RxUtilization
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.TxMaxCellRate
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
315
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.TxMinCellRate
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.TxAvgCellRate
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
This measurement provides the receive cell rate (CLP=0+1) during the busiest minute of the collection interval, expressed in
cells per second.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
Nortel Confidential
316
(Event)
D-Result
(Unit)
E-Type
VS.RxMaxCellRate
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
This measurement provides the receive cell rate (CLP=0+1) during the least busy minute of the collection interval, expressed in
cells per second.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RxMinCellRate
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
This measurement provides the receive cell rate (CLP=0+1) during the collection period, expressed in cells per second.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
317
E-Type
VS.RxAvgCellRate
F-Object Instance
(Location)
AtmPort
G-Switching
Not Applicable
H-3GPP Compliance
I-Available Release
V2
This measurement provides the transmit cell rate (CLP=1) during the busiest minute of the collection interval, expressed in
cells per second.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.TxMaxCellRateClp
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
This measurement provides the transmit cell rate (CLP=1) during the least busy minute of the collection interval, expressed in
cells per second.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.TxMinCellRateClp
F-Object Instance
AtmPort
Nortel Confidential
318
(Location)
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
This measurement provides the transmit cell rate (CLP=1) during the collection interval, expressed in cells per second.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.TxAvgCellRateClp
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RxMaxCellRateClp
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
Nortel Confidential
319
NORTEL # 20014
I-Available Release
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RxMinCellRateClp
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RxAvgCellRateClp
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
320
B-Collection
CC
C-Condition
(Event)
Incremented by one each time a cell (CLP=0+1) is discarded before having been sent.
D-Result
(Unit)
E-Type
VS.TxCellDiscards
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
C-Condition
(Event)
Incremented by one each time a cell (CLP=0+1) is discarded before having been received.
D-Result
(Unit)
E-Type
VS.RxCellDiscards
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
321
B-Collection
CC
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.TxFrameDiscards
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RxFrameDiscards
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
C-Condition
(Event)
Incremented by one each time a cell (CLP=1) is discarded before having been sent.
D-Result
Nortel Confidential
322
(Unit)
Screening = NO
E-Type
VS.TxCellDiscardsClp
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
C-Condition
(Event)
Incremented by one each time a cell (CLP=1) is discarded before having been received.
D-Result
(Unit)
E-Type
VS.RxCellDiscardsClp
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
C-Condition
(Event)
Incremented by one each time a frame (CLP=1) is discarded before having been sent.
D-Result
(Unit)
E-Type
VS.TxFrameDiscardsClp
F-Object Instance
(Location)
AtmPort
G-Switching
NA
Nortel Confidential
323
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
C-Condition
(Event)
Incremented by one each time a frame (CLP=1) is discarded before having been received.
D-Result
(Unit)
E-Type
VS.RxFrameDiscardsClp
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
This measurement provides the transmit cell rate during the busiest minute of the collection interval in cells per second screened
per service category.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.TxMaxCellRate.Cbr
Nortel Confidential
324
VS.TxMaxCellRate.Rtvbr
VS.TxMaxCellRate.Nrtvbr
VS.TxMaxCellRate.Abr
VS.TxMaxCellRate.Ubr
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.TxMinCellRate.Cbr
VS.TxMinCellRate.Rtvbr
VS.TxMinCellRate.Nrtvbr
VS.TxMinCellRate.Abr
VS.TxMinCellRate.Ubr
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
Nortel Confidential
I-Available Release
325
V2
This measurement provides the transmit cell rate during the collection interval in cells per second screened per service category.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.TxAvgCellRate.Cbr
VS.TxAvgCellRate.Rtvbr
VS.TxAvgCellRate.Nrtvbr
VS.TxAvgCellRate.Abr
VS.TxAvgCellRate.Ubr
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
This measurement provides the receive cell rate during the busiest minute of the collection interval in cells per second screened
per service category.
B-Collection
SI
NORTEL LOAD type counter
Nortel Confidential
326
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RxMaxCellRate.Cbr
VS.RxMaxCellRate.Rtvbr
VS.RxMaxCellRate.Nrtvbr
VS.RxMaxCellRate.Abr
VS.RxMaxCellRate.Ubr
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
This measurement provides the receive cell rate during the least
busy minute of the collection interval in cells per second
screened per service category.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
E-Type
327
VS.RxMinCellRate.Cbr
VS.RxMinCellRate.Rtvbr
VS.RxMinCellRate.Nrtvbr
VS.RxMinCellRate.Abr
VS.RxMinCellRate.Ubr
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
This measurement provides the received cell rate during the collection interval in cells per second screened per service category.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
F-Object Instance
VS.RxAvgCellRate.Cbr
VS.RxAvgCellRate.Rtvbr
VS.RxAvgCellRate.Nrtvbr
VS.RxAvgCellRate.Abr
VS.RxAvgCellRate.Ubr
AtmPort
Nortel Confidential
328
(Location)
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
This measurement provides the transmit cell rate (CLP=1) during the busiest minute of the collection interval in cells per second screened per service category.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.TxMaxCellRateClp.Cbr
VS.TxMaxCellRateClp.Rtvbr
VS.TxMaxCellRateClp.Nrtvbr
VS.TxMaxCellRateClp.Abr
VS.TxMaxCellRateClp.Ubr
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
329
ing the least busy minute of the collection interval in cells per
second screened per service category.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.TxMinCellRateClp.Cbr
VS.TxMinCellRateClp.Rtvbr
VS.TxMinCellRateClp.Nrtvbr
VS.TxMinCellRateClp.Abr
VS.TxMinCellRateClp.Ubr
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
This measurement provides the transmit cell rate (CLP=1) during the collection interval in cells per second screened per service category.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
E-Type
330
VS.TxAvgCellRateClp.Cbr
VS.TxAvgCellRateClp.Rtvbr
VS.TxAvgCellRateClp.Nrtvbr
VS.TxAvgCellRateClp.Abr
VS.TxAvgCellRateClp.Ubr
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RxMaxCellRateClp.Cbr
VS.RxMaxCellRateClp.Rtvbr
VS.RxMaxCellRateClp.Nrtvbr
Nortel Confidential
331
VS.RxMaxCellRateClp.Abr
VS.RxMaxCellRateClp.Ubr
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RxMinCellRateClp.Cbr
VS.RxMinCellRateClp.Rtvbr
VS.RxMinCellRateClp.Nrtvbr
VS.RxMinCellRateClp.Abr
VS.RxMinCellRateClp.Ubr
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
332
This measurement provides the transmit cell rate (CLP=1) during the collection interval in cells per second screened per service category.
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RxAvgCellRateClp.Cbr
VS.RxAvgCellRateClp.Rtbvr
VS.RxAvgCellRateClp.Nrtbvr
VS.RxAvgCellRateClp.Abr
VS.RxAvgCellRateClp.Ubr
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
C-Condition
(Event)
Incremented by one each time a cell (CLP=0+1) is discarded before having been sent.
D-Result
(Unit)
Nortel Confidential
E-Type
333
VS.TxCellDiscards.Cbr
VS.TxCellDiscards.Rtvbr
VS.TxCellDiscards.Nrtvbr
VS.TxCellDiscards.Abr
VS.TxCellDiscards.Ubr
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
C-Condition
(Event)
Incremented by one each time a cell (CLP=0+1) is discarded before having been received.
D-Result
(Unit)
E-Type
VS.RxCellDiscards.Cbr
VS.RxCellDiscards.Rtvbr
VS.RxCellDiscards.Nrtvbr
VS.RxCellDiscards.Abr
Nortel Confidential
334
VS.RxCellDiscards.Ubr
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
NORTEL CUM type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.TxFramelDiscards.Cbr
VS.TxFrameDiscard.Rtvbr
VS.TxFrameDiscard.Nrtvbr
VS.TxFrameDiscard.Abr
VS.TxFrameDiscard.Ubr
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
335
B-Collection
CC
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.RxFramelDiscards.Cbr
VS.RxFrameDiscards.Rtvbr
VS.RxFrameDiscards.Nrtvbr
VS.RxFrameDiscards.Abr
VS.RxFrameDiscards.Ubr
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
C-Condition
(Event)
Incremented by one each time a cell (CLP=1) is discarded before having been sent.
D-Result
(Unit)
Nortel Confidential
E-Type
336
VS.TxCellDiscardsClp.Cbr
VS.TxCellDiscardsClp.Rtvbr
VS.TxCellDiscardsClp.Nrtvbr
VS.TxCellDiscardsClp.Abr
VS.TxCellDiscardsClp.Ubr
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
C-Condition
(Event)
Incremented by one each time a cell (CLP=0+1) is discarded before having been received.
D-Result
(Unit)
E-Type
F-Object Instance
VS.RxCellDiscardsClp.Cbr
VS.RxCellDiscardsClp.Rtvbr
VS.RxCellDiscardsClp.Nrtvbr
VS.RxCellDiscardsClp.Abr
VS.RxCellDiscardsClp.Ubr
AtmPort
Nortel Confidential
337
(Location)
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
CC
C-Condition
(Event)
Incremented by one each time a frame (CLP=1) is discarded before having been sent.
D-Result
(Unit)
E-Type
VS.TxFramelDiscardsClp.Cbr
VS.TxFrameDiscardsClp.Rtvbr
VS.TxFrameDiscardsClp.Nrtvbr
VS.TxFrameDiscardsClp.Abr
VS.TxFrameDiscardsClp.Ubr
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
338
B-Collection
CC
C-Condition
(Event)
Incremented by one each time a frame (CLP=1) is discarded before having been received.
D-Result
(Unit)
E-Type
VS.RxFramelDiscardsClp.Cbr
VS.RxFrameDiscardsClp.Rtvbr
VS.RxFrameDiscardsClp.Nrtvbr
VS.RxFrameDiscardsClp.Abr
VS.RxFrameDiscardsClp.Ubr
F-Object Instance
(Location)
AtmPort
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
339
Counter name
# 20103
VS.CpuUtilAvg
# 20104
VS.CpuUtilAvgMin
# 20105
VS.CpuUtilAvgMax
# 20106
VS.MemoryCapacity.
# 20107
VS.MemoryUsageAvg.
# 20108
VS.MemoryUsageAvgMin.
# 20109
VS.MemoryUsageAvgMax.
# 20110
VS.SharedMsgBlockCapacity
# 20111
VS.SharedMsgBlockUsageAvg
# 20112
VS.SharedMsgBlockUsageAvgMin
# 20113
VS.SharedMsgBlockUsageAvgMax
# 20114
VS.LocalMsgBlockCapacity
# 20115
VS.LocalMsgBlockUsageAvg
# 20116
VS.LocalMsgBlockUsageAvgMin
# 20117
VS.LocalMsgBlockUsageAvgMax
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CpuUtilAvg
F-Object Instance
(Location)
Lp
G-Switching
NA
Nortel Confidential
340
H-3GPP Compliance
I-Available Release
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CpuUtilMin
F-Object Instance
(Location)
Lp
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.CpuUtilMax
F-Object Instance
(Location)
Lp
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
341
B-Collection
DER
NORTEL VALUE type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.MemoryCapacity.FastRAM
VS.MemoryCapacity.NormalRAM
VS.MemoryCapacity.SharedRAM
F-Object Instance
(Location)
Lp
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
DER
NORTEL VALUE type counter
C-Condition
(Event)
D-Result
(Unit)
Nortel Confidential
E-Type
342
VS.MemoryUsage.FastRAM
VS.MemoryUsage.NormalRAM
VS.MemoryUsage.SharedRAM
F-Object Instance
(Location)
Lp
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
DER
NORTEL VALUE type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.MemoryUsageAvgMin.FastRAM
VS.MemoryUsageAvgMin.NormalRAM
VS.MemoryUsageAvgMin.SharedRAM
F-Object Instance
(Location)
Lp
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
343
B-Collection
DER
NORTEL VALUE type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.MemoryUsageAvgMax.FastRAM
VS.MemoryUsageAvgMax.NormalRAM
VS.MemoryUsageAvgMax.SharedRAM
F-Object Instance
(Location)
Lp
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
DER
NORTEL VALUE type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.SharedMsgBlockCapacity
F-Object Instance
(Location)
Lp
G-Switching
NA
Nortel Confidential
344
H-3GPP Compliance
I-Available Release
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.SharedMsgBlockUsageAvg
F-Object Instance
(Location)
Lp
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.SharedMsgBlockUsageAvgMin
F-Object Instance
(Location)
Lp
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
345
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.SharedMsgBlockUsageAvgMax
F-Object Instance
(Location)
Lp
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
DER
NORTEL VALUE type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.LocalMsgBlockCapacity
F-Object Instance
(Location)
Lp
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
346
A-Description
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
F-Object Instance
(Location)
Lp
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
SI
NORTEL LOAD type counter
C-Condition
(Event)
D-Result
(Unit)
E-Type
VS.LocalMsgBlockUsageAvgMin
F-Object Instance
(Location)
Lp
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
B-Collection
SI
Nortel Confidential
347
D-Result
(Unit)
E-Type
F-Object Instance
(Location)
Lp
G-Switching
NA
H-3GPP Compliance
I-Available Release
V2
Nortel Confidential
348
Nortel Confidential
349
RAB description
RRC state
Dl RB Set
Traffic class
1 CS RB DTCH 64 Kbps +
4 SRB DCCH 3.4 Kbps
Cell DCH
0
1
Conversational
Cell DCH
2
1
Conversational
1 PS RB DTCH 64 Kbps +
4 SRB DCCH 3.4 Kbps
Cell DCH
3
1
Interactive
Background
Cell DCH
Non Applicable
1 PS RB DTCH 8 Kbps +
4 SRB DCCH 3.4 Kbps
Cell DCH
4
1
Interactive
Background
5
1
Conversational
Cell DCH
6
1
Interactive
Background
Cell DCH
7
1
Interactive
Background
Cell DCH
8
1
Streaming
Cell DCH
2
1
3
Conversational
Interactive
Background
10
Cell DCH
5
1
3
Conversational
Interactive
Background
Nortel Confidential
DASC #
350
RAB description
RRC state
Dl RB Set
Traffic class
11
1 PS RB DTCH 32 Kbps +
4 SRB DCCH 3.4 Kbps
Cell DCH
9
1
Interactive
Background
12
Cell DCH
10
1
Interactive
Background
13
Cell FACH
11
Non applicable
14
Cell DCH
12
1
Streaming
15
Cell DCH
2
4
1
Conversational
Interactive
Background
16
Cell DCH
5
4
1
Conversational
Interactive
Background
17
Cell DCH
2
6
1
Conversational
Interactive
Background
18
Cell DCH
5
6
1
Conversational
Interactive
Background
19
1 PS RB + 4 SRB :
(Always-On on Cell FACH)
Cell FACH
13
11
Interactive
Background
20
Cell DCH
14
1
Interactive
Background
Note: For more information about the RAB description, refer to the RAB configurations.
Nortel Confidential
351
RB configuration
RRC state
Traffic Class
1 DL CS RB DTCH 64 Kbps
Cell DCH
Conversational
Cell DCH
Non apllicable
Conversational
1 DL PS RB DTCH 64 Kbps
Cell DCH
Interactive
Background
1 DL PS RB DTCH 8 Kbps.
Cell DCH
Interactive
Background
Cell DCH
Conversational
Cell DCH
Interactive
Background
Cell DCH
Interactive
Background
Cell DCH
Streaming
1 DL PS RB DTCH 32 Kbps
Cell DCH
Interactive
Background
10
Cell DCH
Interactive
Background
11
12
Cell DCH
13
14
Cell DCH
Streaming
Interactive
Background
Nortel Confidential
352
Name
DL RB Set
UL RB Set
RabOther
RabCsConv12_2
RabCsConv64
RabCsStr14_4
RabCsStr57_6
RabPsInter8D_32U
RabPsBgnd8D_32U
RabPsInter8D_8U
RabPsBgnd8D_8U
RabPsInter32D_32U
10
RabPsBgnd32D_32U
11
RabPsInter64D_64U
12
RabPsBgnd64D_64U
13
RabPsStr64D_64U
14
RabPsInter128D_64U
15
RabPsBgnd128D_64U
16
RabPsStr128D_64U
17
RabPsInter128D_128U
18
19
RabPsStr128D_128U
20
RabPsInter384D_64U
21
RabPsBgnd384D_64U
22
RabPsStr384D_64U
23
RabPsInter256D_64U
24
RabPsBgnd256D_64U
25
RabPsStr256D_64U
Nortel Confidential
353
Nortel Confidential
354
RAB description
RRC state
Ul RB Set
Traffic class
1 PS RB DTCH 64 Kbps +
4 SRB DCCH 3.4 Kbps
Cell DCH
0
1
Interactive
Background
Cell DCH
2
1
Conversational
1 PS RB DTCH 64 Kbps +
4 SRB DCCH 3.4 Kbps
Cell DCH
Non applicable
Cell DCH
3
1
Interactive
Background
1 PS RB DTCH 8 Kbps +
4 SRB DCCH 3.4 Kbps
Cell DCH
4
1
Conversational
5
1
Conversational
Cell DCH
6
1
Streaming
Cell DCH
2
0
1
Conversational
Interactive
Background
Cell DCH
5
0
1
Conversational
Interactive
Background
1 PS RB DTCH 8 kbps +
4 SRB DCCH 3.4 kbps
Cell DCH
7
1
Interactive
Background
10
Cell DCH
8
1
Interactive
Background
Nortel Confidential
UASC #
355
RAB description
RRC state
Ul RB Set
Traffic class
11
Cell FACH
Non applicable
12
Cell DCH
10
1
Streaming
13
Cell DCH
2
7
1
Conversational
Interactive
Background
14
Cell DCH
5
7
1
Conversational
Interactive
Background
15
1 PS RB + 4 SRB
(Always-On on Cell_FACH)
Cell FACH
11
9
Interactive
Background
16
Cell DCH
12
1
Interactive
Background
Note: For more information about the RAB description, refer to the RAB configurations.
Nortel Confidential
356
Nortel Confidential
357
Causes
Name
RRC.SuccConnEstab.0
RRC.SuccConnEstab.1
RRC.SuccConnEstab.2
RRC.SuccConnEstab.3
RRC.SuccConnEstab.4
RRC.SuccConnEstab.5
RRC.SuccConnEstab.6
RRC.SuccConnEstab.7
RRC.SuccConnEstab.8
Emergency call
RRC.SuccConnEstab.9
10
RRC.SuccConnEstab.10
11
RRC.SuccConnEstab.11
12
Registration
RRC.SuccConnEstab.12
13
Detach
RRC.SuccConnEstab.13
14
RRC.SuccConnEstab.14
15
RRC.SuccConnEstab.15
16
Call reestablishment
RRC.SuccConnEstab.16
17
RRC.SuccConnEstab.17
18
RRC.SuccConnEstab.18
19
RRC.SuccConnEstab.19
20
Note: Subcounters #14-15 have been modified in V2 (due to modifications in 3GPP TS 25.331
3.7.0.) and #17-19 have been added in V2.
Nortel Confidential
358
Causes
Name
Normal release
NormalEvent
UnspecifiedSccpReleaseCause
Preemptive release
PreemptiveRelease
Congestion
Congestion
Reestablishment reject
ReestablishmentReject
User inactivity
UserInactivity
DirectedSignallingConnectionReestablishement
RelcauseSpare
Nortel Confidential
Index
359
#0014
(VS.NumberUeWithNRadioLinks..<Nb
Rl>.Max) 78
#0001 (VS.RadioLinkSetupSuccess.) 31
#0014
#0002 (VS.RadioLinkSetupUnsuccess.)
(VS.NumberUeWithNRadioLinks..<Nb
32
Rl>.Min) 78
#0003 (VS.RadioLinkAdditionSuccess. 33
#0015 (VS.RrcSleepyCellInactivity) 87
#0004 (VS.RadioLinkAdditionUnsuccess.)
#0016 (VS.RlSleepyCellInactivity) 42
34
#0017 (VS.PagingSleepyCellInactivity)
#0005 (VS.RadioLinkDeletionSuccess)
139
35
#0101 (VS.RrcHoFromUtranCommand.)
#0006 (VS.RadioLinkDeletionUnsuccess)
44
35
#0102
#0007
(VS.RrcHoFromUtranCommandNeighbRnc.)
(VS.RadioLinkReconfigurationPrepareSuccess.)
45
36
#0103
(VS.RrcHoFromUtranFailure.) 46
#0008
#0104
(VS.RadioLinkReconfigurationPrepareUnsuccess.)
(VS.RrcHoFromUtranFailureNeighbRnc.)
36
46
#0009
(VS.RadioLinkReconfigurationCancelSuccess.)#0105 (IRATHO.AttOutPSUTRAN) 47
#0106
38
(VS.RrcCellChangeOrderNeighbRnc) 48
#0010
#0107 (IRATHO.FailOutPS) 48
(VS.RadioLinkReconfigurationCommitSuccess.)
#0108
38
(VS.RrcCellChangeOrderFailureNeighbRnc.)
#0011
49
(VS.RadioLinkEstablishedPerCell..Max)
#0109
41
(VS.3gTo2gHoDetectionFromFddcell.) 50
#0011
#0110
(VS.RadioLinkEstablishedPerCell.Avg)
(VS.3gTo2gHoDetectionFromFddcellNeighbRnc.)
40
50
#0011
#0111
(VS.RadioLinkEstablishedPerCell.Cum)
(VS.IntraRncOutgoingBlindHoAttempt.)
39
51
#0011
#0112
(VS.RadioLinkEstablishedPerCell.Min) 41
(VS.IntraRncOutgoingBlindHoFailure. 52
#0011
#0113 (VS.IntraRncIncomingHoAttempt.)
(VS.RadioLinkEstablishedPerCell.NbEvt)
52
39
#0114 (VS.IntraRncIncomingHoFailure.
#0013
53
(VS.RadioLinkDroppedLastRadioLink.)
#0119
42
(VS.InterPlmnOutgoingHardHoAttempt.)
#0014
56
(VS.NumberUeWithNRadioLinks..<Nb
#0120
Rl>.Avg) 77
(VS.InterPlmnOutgoingHardHoFailure.)
Numerics
Nortel Confidential
Index
360
56
(VS.AveragePowerUsedForData.Min) 69
#0121
#0302
(VS.InterPlmnOutgoingHardHoSuccess)
(VS.AveragePowerUsedForData.NbEvt)
57
68
#0122
#0303 (VS.UplinkRSSI.Avg) 71
(VS.WithoutIurIncomingHardHoAttempt.)
#0303 (VS.UplinkRSSI.Cum) 70
54
#0303 (VS.UplinkRSSI.Max) 72
#0123
#0303 (VS.UplinkRSSI.Min) 71
(VS.WithoutIurIncomingHardHoFailure.)
#0303 (VS.UplinkRSSI.NbEvt) 70
54
#0304
#0124
(VS.AveragePowerUsedForSignalling.Avg)
(VS.WithoutIurIncomingHardHoSuccess.)
73
55
#0304
#0125
(VS.AveragePowerUsedForSignalling.Cum)
(VS.InterRncWithoutIurIncomingHardHoAttempt.)
72
58
#0304
#0126
(VS.AveragePowerUsedForSignalling.Max)
(VS.InterRncWithoutIurIncomingHardHoFailure.)74
58
#0304
#0127
(VS.AveragePowerUsedForSignalling.Min)
(VS.InterRncWithoutIurIncomingHardHoSuccess.)
74
59
#0304
#0301
(VS.AveragePowerUsedForSignalling.NbEvt)
(VS.AveragePowerUsedForSpeech.Avg)
73
66
#0305
#0301
(VS.AveragePowerUsedForMiscellaneous.Avg)
(VS.AveragePowerUsedForSpeech.Cum)
74
65
#0305
#0301
(VS.AveragePowerUsedForMiscellaneous.Max)
(VS.AveragePowerUsedForSpeech.Max)
75
67
#0305
#0301
(VS.AveragePowerUsedForMiscellaneous.Min)
(VS.AveragePowerUsedForSpeech.Min)
75
67
#0401 (SHO.SuccRLAddUESid) 63
#0301
#0402
(VS.AveragePowerUsedForSpeech.NbEvt)
(VS.RrcActiveSetUpdateUnsuccess.) 79
66
#0403 (RRC.SuccConnEstab.) 88
#0302
#0404 (RRC.FailConnEstab.) 88
(VS.AveragePowerUsedForData.Avg) 69
#0405 (VS.RrcConnectionRelease.) 89
#0302
#0406
(VS.AveragePowerUsedForData.Cum)
(VS.RrcActiveSetUpdateSuccessNeighbRnc.)
68
80
#0302
#0407
(VS.AveragePowerUsedForData.Max) 69
(VS.RrcActiveSetUpdateUnsuccessNeighbRnc.)
#0302
80
UMT/DCL/DD/0022 04.09/EN Standard June 2005
4118111822
Nortel Confidential
Index
361
#0408
(VS.IuCsTimingAdjustmentRequests.)
(VS.RrcConnectionReleaseNeighbRnc)
106
90
#0528 (VS.IuCsTimingAdjustmentAcks.
#0409 (RRC.AttConnEstab.) 90
106
#0411 (VS.RrcAvgActiveSetSize.Avg) 81
#0529 (VS.IuCsTimingAdjustmentNacks.)
#0411 (VS.RrcAvgActiveSetSize.Max) 83
107
#0411 (VS.RrcAvgActiveSetSize.Min) 82
#0530
#0412
(VS.IuCsTimingAdjustmentUnsupported.)
(VS.RrcTransitionCellFachToCellDch.) 83
108
#0413
#0531
(VS.RrcTransitionCellDchToCellFach) 84
(VS.IuCsTimingAdjustmentTimeouts.)
#0414 (VS.RrcAvgNbrCellFach.Avg) 84
108
#0414 (VS.RrcAvgNbrCellFach.Max) 85
#0532
#0414 (VS.RrcAvgNbrCellFach.Min) 85
(VS.IuEmittedSccpAbnormalDisconnectsCs.)
#0415
109
(VS.RrcActiveSetUpdateCompleteProcedure) #0533 (VS.IuAbnormalReleaseRequestCs)
86
109
#0501 (VS.IuSccpCnxSuccess.) 93
#0534 (VS.IuAbnormalReleaseRequestPs)
#0502 (VS.IuSccpCnxUnsuccess.) 93
110
#0503 (VS.IuReleaseRequestCs) 94
#0535 (VS.IuRelocationRequests.) 111
#0504 (VS.IuReleaseRequestPs) 94
#0536
#0505 (VS.IuReleaseCommandCs.) 95
(VS.IuRelocationRequestFailuresCs.)
#0506 (VS.IuReleaseCommandPs.) 96
111
#0511 (VS.IuRelocationCancels.) 97
#0537
#0512 (VS.IuRelocationCompletes.) 98
(VS.IuRelocationRequestFailuresPs.) 112
#0513 (VS.IuRelocationDetects.) 99
#0601 (VS.RadioBearerSetupSuccess.)
#0516
115
(VS.IuReceivedSccpAbnormalDisconnectsCs) #0602 (VS.RadioBearerSetupUnsuccess.)
99
115
#0517
#0603
(VS.IuEmittedSccpAbnormalDisconnectsPs.) (VS.RadioBearerEstablishmentUnsuccess.)
100
116
#0518
#0604 (VS.RabAssignmentSetupSuccess.)
(VS.IuReceivedSccpAbnormalDisconnectsPs) 117
100
#0605
#0520 (VS.IuAvgNbrSccpCnx.Avg) 101
(VS.RabAssignmentSetupUnsuccess.)
#0520 (VS.IuAvgNbrSccpCnx.Max) 101
118
#0520 (VS.IuAvgNbrSccpCnx.Min) 102
#0606
#0521 (VS.IuRelocationRequired.) 102
(VS.RabAssignmentReleaseSuccess.)
#0524 (VS.IuRelocationCommands.) 103
119
#0525 (VS.
#0607
IuRelocationCommandFailuresCs.) 104
(VS.RabAssignmentReleaseUnsuccess.)
#0526 (VS.
119
IuRelocationCommandFailuresPs.) 105
#0608 (VS.RadioBearerReleaseSuccess.)
#0527
120
Copyright 2003-2005 Nortel Networks
Nortel Confidential
Index
362
#0609
133
(VS.RadioBearerReleaseUnsuccess.)
#0620
121
(VS.UlAsConfIdAvgNbrEstablished.Min)
#0610
133
(VS.RadioBearerSetupSuccessNeighbRnc.) #0621
122
(VS.RabEstablishmentRequestsPerRabType.)
#0611
134
(VS.RadioBearerSetupUnsuccessNeighbRnc.)
#0622
123
(VS.RabEstablishmentSuccessPerRequestedRabTy
#0612
134
(VS.RadioBearerEstablishmentUnsuccessNeighbRnc.)
123
#0613
(VS.RadioBearerReleaseSuccessNeighbRnc.) #0623
(VS.RabEstablishmentSuccessPerGrantedRabType
124
135
#0614
#0701
VS.SmcSuccess.) 136
(VS.RadioBearerReleaseUnsuccessNeighbRnc.)
#0702 VS.RejectedSmc.) 136
125
#0703 (VS.FailedSmc.) 137
#0615
#0801 (VS.ReceivedPagingRequest.)
(VS.RadioBearerReconfigurationSuccess.)
140
126
#0802
#0616
(VS.RadioBearerReconfigurationUnsuccess.) (VS.ReceivedPagingRequestType2CellDch.)
140
127
#0803
#0617
(VS.ReceivedPagingRequestType2CellFach.)
(VS.RadioBearerReconfigurationSuccessNeighbRnc.)
141
127
#0804
(VS.PagingRecordsSentOnPcch)
#0618
141
(VS.RadioBearerReconfigurationUnsuccessNeighbRnc.)
#0805 (VS.PagingMessagesSentOnPcch)
128
142
#0619 (VS.RabAvgNbrEstablished.Avg)
#0806 (VS.PagingUnscheduledRecords)
130
143
#0619 (VS.RabAvgNbrEstablished.Cum)
#0807 (VS.PagingCancelledRecords)
129
143
#0619 (VS.RabAvgNbrEstablished.Max)
#0808 (VS.PagingRejectedRequests)
131
144
#0619 (VS.RabAvgNbrEstablished.Min)
#0809 (VS.PagingDelayedRecords) 144
131
#0810 (VS.UnhandledPagingRequestsCs)
#0619 (VS.RabAvgNbrEstablished.NbEvt)
145
130
#0811
(VS.UnhandledPagingRequestsPs.)
#0620
146
(VS.UlAsConfIdAvgNbrEstablished.Avg)
#0901 (VS.NbrCellUpdates.) 148
132
#0902 (VS.NbrCellUpdateRejects.) 149
#0620
#0903
(VS.UlAsConfIdAvgNbrEstablished.Max)
Numerics
Nortel Confidential
Index
363
(VS.CsLocationReportingControlDefaultLs)
(VS.UeLocationUebasedAgpsUnsuccessNeighbRnc
150
160
#0904
#10001 (VS.PcmLos) 252
(VS.CsLocationReportingControlEmergencyLs)#10002 (VS.PcmAis) 253
150
#10003 (VS.PcmLfa) 253
#0905
#10004 (VS.PcmFe) 254
(VS.PsLocationReportingControlDefaultLs)
#10005 (VS.PcmCrc) 254
151
#10006 (VS.PcmRai) 254
#0906
#10007 (VS.PcmFas) 255
(VS.CsLocationReportSuccessDefaultLsWithinQoS)
#10008 (VS.PcmEbits) 255
151
#10009 (VS.PcmBpv) 256
#0907
#1001 (VS.IrmcacDistributionEcN0.) 161
(VS.CsLocationReportUnsuccessDefaultLs.) #10010 (VS.PcmSlip) 256
152
#10011 (VS.PcmEs) 257
#0908
#10012 (VS.PcmSes) 257
(VS.CsLocationReportSuccessEmergencyLsWithinQoS.UeBasedAgps)
#10013 (VS.PcmBbe) 258
153
#10014 (VS.PcmUas) 258
#0909
#1002 (VS.AvgTxPower.Avg) 163
(VS.CsLocationReportSuccessEmergencyLsOutsideQoS.CellId.UeBasedAgps)
#1002 (VS.AvgTxPower.Cum) 162
153
#1002 (VS.AvgTxPower.Max) 164
#0910
#1002 (VS.AvgTxPower.Min) 164
(VS.CsLocationReportUnsuccessEmergencyLs.)
#1002 (VS.AvgTxPower.NbEvt) 163
154
#1003 (VS.CmConfigurationFailure) 165
#0911
#1004 (VS.CmActivationSuccess 165
(VS.PsLocationReportSuccessDefaultLsWithinQoS)
#1005 (VS.CmActivationFailure) 166
155
#0912
(VS.PsLocationReportUnsuccessDefaultLs.)
#1006 (VS.CmConfigurationSuccess.)
155
166
#0913
#1007
(VS.CsLocationUebasedAgpsSuccess)
(VS.IntraFreqMeasPeriodicModeEventModeCell)
156
167
#0914
#1008
(VS.CsLocationUebasedAgpsUnsuccess.)
(VS.IntraFreqMeasPeriodicModeToEventModeNeigh
156
167
#0915
#1009
(VS.UeLocationUebasedAgpsSuccess.)
(VS.IntraFreqMeasEventModeToPeriodicModeCell)
157
168
#0916
#1010
(VS.UeLocationUebasedAgpsSuccessNeighbRnc.)
(VS.IntraFreqMeasEventModeToPeriodicModeNeigh
158
169
#0917
#10101 (VS.AAL2NbReceivedCell) 260
(VS.UeLocationUebasedAgpsUnsuccess.)
#10102 (VS.AAL2NbLostCPS) 261
159
#10103 (VS.AAL2NbCpsInvalidCIDErr)
#0918
Numerics
Nortel Confidential
Index
364
261
#1014
#10104 (VS.AAL2NbSequenceNumberErr)
(VS.IntraFreqMeasAverageOfCallEventModeNeighR
262
176
#10105 (VS.AAL2NbCPSHecErr) 262
#1014
#10106 (VS.AAL2NbCPSLengthErr) 263
(VS.IntraFreqMeasAverageOfCallEventModeNeighR
#10107 (VS.AAL2NbCpsLengthMismatch)
177
263
#1014
#10108 (VS.AAL2NbCPSInvalidCIDErr)
(VS.IntraFreqMeasAverageOfCallEventModeNeighR
264
177
#10109 (VS.AAL2NbOSFBiggerThan47)
264
#1011
#1015 (VS.MeasurementControlFailure)
(VS.IntraFreqMeasAverageOfCallPeriodicModeCell.Avg)
178
169
# 10201
#1011
(VS.RadioWBandRxMainPwr.Avg) 270
(VS.IntraFreqMeasAverageOfCallPeriodicModeCell.Max)
# 10201
170
(VS.RadioWBandRxMainPwr.Cum) 269
#1011
# 10201
(VS.IntraFreqMeasAverageOfCallPeriodicModeCell.Min)
(VS.RadioWBandRxMainPwr.Max) 271
171
# 10201 (VS.RadioWBandRxMainPwr.Min)
#10110 (VS.AAL5NbReceivedCell) 264
271
#10111 (VS.AAL5NbAbortErr) 265
# 10201
#10112 (VS.AAL5NbLengthErr) 265
(VS.RadioWBandRxMainPwr.NbEvt) 270
#10113 (VS.AAL5NbCrcFrameErr) 266
# 10202 (VS.RadioWBandRxDivPwr.Avg)
#10114 (VS.AAL5NbInvalidSize) 266
273
#10115 (VS.AAL2NbSentCell) 267
# 10202 (VS.RadioWBandRxDivPwr.Cum)
#10116 (VS.AAL5NbSentCell) 267
272
#1012
# 10202 (VS.RadioWBandRxDivPwr.Max)
(VS.IntraFreqMeasAverageOfCallPeriodicModeNeighbRnc.Avg)
274
172
# 10202 (VS.RadioWBandRxDivPwr.Min)
#1012
273
(VS.IntraFreqMeasAverageOfCallPeriodicModeNeighbRnc.Max)
# 10202
172
(VS.RadioWBandRxDivPwr.NbEvt) 272
#1012
# 10203 (VS.RadioTxCarrierPwr.Avg)
(VS.IntraFreqMeasAverageOfCallPeriodicModeNeighbRnc.Min)
275
173
# 10203 (VS.RadioTxCarrierPwr.Cum)
#1013
274
(VS.IntraFreqMeasAverageOfCallEventModeCell.Avg)
# 10203 (VS.RadioTxCarrierPwr.Max)
174
276
#1013
# 10203 (VS.RadioTxCarrierPwr.Min) 275
(VS.IntraFreqMeasAverageOfCallEventModeCell.Max)
# 10203 (VS.RadioTxCarrierPwr.NbEvt)
175
275
#1013
# 10204 (VS.MCPAPwr.avg) 277
(VS.IntraFreqMeasAverageOfCallEventModeCell.Min)
# 10204 (VS.MCPAPwr.Cum 276
175
Numerics
Nortel Confidential
Numerics
# 10306 (VS.RachAckSquare) 287
#10401 (VS.longestTaskLock) 289
#10402 (VS.wdgPcfyItvl) 289
#10403 (VS.CpuLoad.Avg) 291
#10403 (VS.CpuLoad.Cum) 290
#10403 (VS.CpuLoad.Max) 291
#10403 (VS.CpuLoad.Min) 292
#10403 (VS.CpuLoad.NbEvt) 290
#10404 (VS.IsrNestingDepth) 292
#10405 (VS.TotalisrCount) 293
#10601 (VS.ImaGroupUnavailSecs) 296
#10602 (VS.ImaGroupNeNumFailures)
297
#10603 (VS.ImaLinkImaViolations) 297
#10604 (VS.ImaLinkNeSevErroredSecs)
298
#10605 (VS.ImaLinkFeSevErroredSecs)
298
#10606 (VS.ImaLinkNeUnavailSecs) 299
#10607 (VS.ImaLinkFeUnavailSecs) 299
#10608 (VS.ImaLinkNeTxUnusableSecs)
300
#10609 (VS.ImaLinkNeRxUnusableSecs)
300
#10610 (VS.ImaLinkFeTxUnusableSecs)
301
Copyright 2003-2005 Nortel Networks
Index
365
#10611 (VS.ImaLinkFeRxUnusableSecs)
301
#10612 (VS.ImaLinkNeTxNumFailures)
302
#10613 (VS.ImaLinkNeRxNumFailures)
302
#10701 (VS.IfInOctets) 304
#10702 (VS.IfInUcastPkts) 305
#10703 (VS.IfInNUcastPkts) 305
#10704 (VS.IfInDiscards) 305
#10705 (VS.IfInErrors) 306
#10706 (VS.IfInUnknownProtos) 306
#10707 (VS.ifOutOctets) 307
#10708 (VS.IfOutUcastPkts) 307
#10709 (VS.IfOutNUcastPkts) 308
#10710 (VS.IfOutDiscards) 308
#10711 (VS.IfOutErrors) 309
#1101 (VS.DownsizingStep1Success.)
180
#1102
(VS.DownsizingStep1SuccessNeighbRnc.)
180
#1103 (VS.DownsizingStep1UnSuccess.)
181
#1104
(VS.DownsizingStep1UnsuccessNeighbRnc.)
182
#1105 (VS.DownsizingStep2Success.)
183
#1106
(VS.DownsizingStep2SuccessNeighbRnc.)
183
#1107 (VS.UpsizingSuccess.) 184
#1108 (VS.UpsizingSuccessNeighbRnc.)
185
#1109 (VS.UpsizingUnsuccess.) 186
#1110
(VS.UpsizingUnsuccessNeighbRnc.) 186
#1111 (VS.IrmcacMaintainedHighPriority.)
187
#1112
(VS.IrmcacDowngradedHighPriority.) 188
#1113 (VS.IrmcacRejectedHighPriority.)
188
#1114
Access Network Observation Counters
Nortel Confidential
Index
366
acMaintainedMediumPriority.) 189
#1215
#1115
(VS.CommonMacDownlinkDcchOverFachSdu)
(VS.IrmcacDowngradedMediumPriority.)
203
189
#1216
#1116
(VS.CommonMacDownlinkDtchOverFachSdu)
(VS.IrmcacRejectedMediumPriority.) 190
204
#1117 (VS.IrmcacMaintainedLowPriority.)
#1217 (VS.CommonMacUplinkCcchSdu)
191
204
#1118
#1218
(VS.IrmcacDowngradedLowPriority.) 191
(VS.CommonMacUplinkDcchOverRachSdu)
#1119 (VS.IrmcacRejectedLowPriority.)
204
192
#1219
#1120
(VS.CommonMacUplinkDtchOverRachSdu)
(VS.IRMSchedulingDowngradedSuccess.)
205
192
#1220
#1121
(VS.CommonRlcCcchDownlinkKbytes)
(VS.IRMSchedulingDowngradedFailure.)
205
193
#1221 (VS.CommonRlcCcchDownlinkSdu)
#1122
206
(VS.IRMSchedulingDowngradedSuccessNeighbRnc.)
#1222 (VS.CommonRlcCcchDiscardSdu)
194
206
#1123
#1223 (VS.CommonRlcCcchPadding)
(VS.IRMSchedulingDowngradedFailureNeighbRnc.)
207
194
#1224
#1124 (VS.IRMTimeCellColorRed) 195
(VS.CommonUplinkTrafficChnlSyncFrames)
#1125 (VS.IRMTimeCellColorYellow) 196
207
#1126
#1225
(VS.IRMTimeFreeDlCodesBySpreadingFactor.#i.Avg)
(VS.CommonUplinkTimingAdjustmentFrames)
196
208
#1126
#1301
(VS.IRMTimeFreeDlCodesBySpreadingFactor.#i.Max)
(VS.IurDrncRadioLinkSetupSuccess.)
197
209
#1126
#1302
(VS.IRMTimeFreeDlCodesBySpreadingFactor.#i.Min)
(VS.IurDrncRadioLinkSetupUnsuccess.)
198
210
#1127 (VS.IRMTimeCellColorGreen) 198
#1303
#1128 (VS.IrmcacDistributionRscp.) 199
(VS.IurDrncRadioLinkAdditionSuccess.)
#1129 (VS.IrmcacRadioLinkColorRed)
211
200
#1304
#1130 (VS.IrmcacRadioLinkColorGreen)
(VS.IurDrncRadioLinkAdditionUnsuccess.)
200
211
#1213
#1306
(VS.CommonMacDownlinkPcchSdu) 202
(VS.IurDrncRadioLinkDeletionSuccess)
#1214
212
(VS.CommonMacDownlinkCcchSdu) 203
#1307
UMT/DCL/DD/0022 04.09/EN Standard June 2005
4118111822
Nortel Confidential
Index
367
(VS.IurDrncRadioLinkReconfigurationPrepareSuccess.)
(VS.DedicatedUplinkMissingPduRlcSrb.)
213
228
#1308
#1408
(VS.IurDrncRadioLinkReconfigurationPrepareUnsuccess.)
(VS.DedicatedDownlinkDiscardSduRlcSrb.)
214
229
#1309
#1409
(VS.IurDrncRadioLinkReconfigurationCancelSuccess.)
(VS.DedicatedDownlinkPaddingSduRlcSrb.)
214
229
#1310
#1410
(VS.IurDrncRadioLinkReconfigurationCommitSuccess.)
(VS.DedicatedUplinkKbytesRlcCsData.)
215
230
#1311 (VS.IurSccpCnxSuccess.) 217
#1411
#1312 (VS.IurSccpCnxUnsuccess.) 218
(VS.DedicatedDownlinkKbytesRlcCsData.)
#1315 (VS.IurAvgNbrInitSccpCnx.Avg)
230
218
#1412
#1315 (VS.IurAvgNbrInitSccpCnx.Max)
(VS.DedicatedUplinkPduRlcCsData.) 231
219
#1413
#1315 (VS.IurAvgNbrInitSccpCnx.Min)
(VS.DedicatedDownlinkPduRlcCsData.)
219
232
#1316 (VS.IurAvgNbrTermSccpCnx.Avg)
#1414
220
(VS.DedicatedUplinkSduRlcCsData.) 232
#1316 (VS.IurAvgNbrTermSccpCnx.Max)
#1415
220
(VS.DedicatedDownlinkSduRlcCsData.)
#1316 (VS.IurAvgNbrTermSccpCnx.Min)
233
221
#1416
#1317
(VS.DedicatedUplinkMissingPduRlcCsData.)
(VS.IurEmittedSccpAbnormalDisconnects.)
234
222
#1417
#1318
(VS.DedicatedDownlinkDiscardSduRlcCsData.
(VS.IurReceivedSccpAbnormalDisconnects)
234
222
#1418
#1401 (VS.DedicatedUplinkKbytesRlcSrb.)
(VS.DedicatedDownlinkPaddingSduRlcCsData.)
225
235
#1402
#1419 (VS.DedicatedUplinkKbytesRlcPs.)
(VS.DedicatedDownlinkKbytesRlcSrb.)
236
225
#1420
#1403 (VS.DedicatedUplinkPduRlcSrb.)
(VS.DedicatedDownlinkKbytesRlcPs.)
226
236
#1404 (VS.DedicatedDownlinkPduRlcSrb.)
#1421 (VS.DedicatedUplinkPduRlcPs.)
226
237
#1405 (VS.DedicatedUplinkSduRlcSrb.)
#1422 (VS.DedicatedDownlinkPduRlcPs.)
227
237
#1406 (VS.DedicatedDownlinkSduRlcSrb.)
#1423 (VS.DedicatedUplinkSduRlcPs.)
228
238
#1407
#1424 (VS.DedicatedDownlinkSduRlcPs.)
Copyright 2003-2005 Nortel Networks
Nortel Confidential
Index
368
239
# 20016 (VS.RxAvgCellRateClp) 319
#1425
# 20017 (VS.TxCellDiscards) 320
(VS.DedicatedUplinkMissingPduRlcPs.)
# 20018 (VS.RxCellDiscards) 320
239
# 20019 (VS.TxFrameDiscards) 320
#1426
# 20020 (VS.RxFrameDiscards) 321
(VS.DedicatedDownlinkDiscardSduRlcPs.
# 20021 (VS.TxCellDiscardsClp) 321
240
# 20022 (VS.RxCellDiscardsClp) 322
#1427
# 20023 (VS.TxFrameDiscardsClp) 322
(VS.DedicatedDownlinkPaddingSduRlcPs.) # 20024 (VS.RxFrameDiscardsClp) 323
241
# 20025 (VS.TxMaxCellRate.) 323
#1429 (VS.DedicatedUplinkBadPdusCs.)
# 20026 (VS.TxMinCellRate.) 324
241
# 20027 (VS.TxAvgCellRate.) 325
#1430 (VS.DedicatedUplinkBadPdusPs.)
# 20028 (VS.RxMaxCellRate.) 325
242
# 20029 (VS.RxMinCellRate.) 326
#1431
# 20030 (VS.RxAvgCellRate.) 327
(VS.DedicatedUplinkVoiceABitsGoodFrames.) # 20031 (VS.TxMaxCellRateClp.) 328
243
# 20032 (VS.TxMinCellRateClp.) 328
#1432
# 20033 (VS.TxAvgCellRateClp.) 329
(VS.DedicatedUplinkVoiceABitsBadFrames.) # 20034 (VS.RxMaxCellRate.Clp) 330
243
# 20035 (VS.RxMinCellRateClp.) 331
#1433
# 20036 (VS.RxAvgCellRateClp.) 332
(VS.DedicatedDownlinkActivityRlcCs.)
# 20037 (VS.TxCellDiscards.) 332
244
# 20038 (VS.RxCellDiscards.) 333
#1434 (VS.DedicatedUplinkActivityRlcCs.)
# 20039 (VS.TxFrameDiscards.) 334
244
# 20040 (VS.RxFrameDiscards.) 335
#1435
# 20041 (VS.TxCellDiscardsClp.) 335
(VS.DedicatedDownlinkActivityRlcPs.)
# 20042 (VS.RxCellDiscardsClp.) 336
245
# 20043 (VS.TxFrameDiscardsClp.) 337
#1436 (VS.DedicatedUplinkActivityRlcPs.)
# 20044 (VS.RxFrameDiscardsClp.) 337
246
# 20103 (VS.CpuUtilAvg) 339
# 20001 (VS.ProvRate) 312
# 20104 (VS.CpuUtilAvgMin) 340
# 20002 (VS.ActualRate) 312
# 20105 (VS.CpuUtilAvgMax) 340
# 20003 (VS.TxUtilization) 313
# 20106 (VS.MemoryCapacity.) 341
# 20004 (VS.RxUtilization) 313
# 20107 (VS.MemoryUsageAvg.) 341
# 20005 (VS.TxMaxCellRate) 314
# 20108 (VS.MemoryUsageAvgMin.) 342
# 20006 (VS.TxMinCellRate) 314
# 20109 (VS.MemoryUsageAvgMax.) 343
# 20007 (VS.TxAvgCellRate) 315
# 20110 (VS.MemoryCapacity) 343
# 20008 (VS.RxMaxCellRate) 315
# 20111 (VS.SharedMsgBlockUsageAvg)
# 20009 (VS.RxMinCellRate) 316
344
# 20010 (VS.RxAvgCellRate) 316
# 20112
# 20011 (VS.TxMaxCellRateClp) 317
(VS.SharedMsgBlockUsageAvgMin) 344
# 20012 (VS.TxMinCellRateClp) 317
# 20113
# 20013 (VS.TxAvgCellRateClp) 318
(VS.SharedMsgBlockUsageAvgMax) 345
# 20014 (VS.RxMaxCellRateClp) 318
# 20114 (VS.LocalMsgBlockCapacity)
# 20015 (VS.RxMinCellRateClp) 319
345
UMT/DCL/DD/0022 04.09/EN Standard June 2005
4118111822
Nortel Confidential
Index
369
# 20115 (VS.LocalMsgBlockUsageAvg)
345
# 20116
(VS.LocalMsgBlockUsageAvgMin) 346
# 20117
(VS.LocalMsgBlockUsageAvgMax) 346
#3001 (VS.E3PrLoadCnTmu.xxx.Avg)
248
#3001 (VS.E3PrLoadCnTmu.xxx.Cum)
247
#3001 (VS.E3PrLoadCnTmu.xxx.Max)
249
#3001 (VS.E3PrLoadCnTmu.xxx.Min)
250
#3001 (VS.E3PrLoadCnTmu.xxx.NbEvt)
248
D
Downlink Access Stratum Configuration
(DASC) 349
Downlink Radio Bearer Set Configuration
(DRBS) 351
R
RAB configurations 352
RRC connection establishment causes
357
RRC connection release causes 358
S
SHO.AttRLAddUTRANSide 60
SHO.FailRLAddUTRANSide. 61
SHO.SuccRLAddUTRANSide 61
SHO.SuccRLDelUESid 63
SHO.SuccRLDelUTRANSide 62
U
Uplink Access Stratum Configuration
(UASC) 354
UMT/DCL/DD/0022
4118111822
04.09/EN
Standard
UMTS V 4.0
June 2005