Windows setting sheetWindows 7 SP1/Server2008R2 SP1/ for CENTUM VP R5.

01
Customer Name:

Setting Items
The confirmation of the wearing positions such as attached cards

Correct Setting

Screen to confirm

User Name

Confirm whether it is put on at constitution, the position that matched


specifications.
y_admin

Password

yokogawa

(Confirm it before power supply injection by all means!!

Login screen at
first time start
gpedit.msc
Computer
Properties

SIC-33Q6-004E R4

JOB NAMEDOMAINSTATION

[Computer Configuration]-[Administrative Templates]-[system]-[Internet


Communication Manegement]-[Internet Communication Setting]

Enable the [Turn off Windows Customer Experience Improvement Program]

Computer Name,Domain
Name, and Workgroup
setting

HIS0164(Check correct computer name based on the domain and station


number)
"WORKGROUP"

Setting and changing Computer Name


Workgroup

Device Manager
Driver Install
Advanced system settings

Performance Options

[Visual Effects]

Virtual memory

Write an event to the


system log
Automatically restart
Write debugging
information
Overwrite any
existing file

y_admin
y_admin
y_admin

Confirm that implemented cards are recognized

y_admin

Confirm that there is no error

y_admin

Install the driver corresponding to the hardware(VF, VI, AIP etc.)

y_admin

Winodws7check the option [Let Windows choose whats best for my


computer].
Server2008check the option {Adjust for best performance}
Installed memory size x 1.5 (4GB=6144MB6GB=9216MB)
PC Restart required.

Choose [Custom size]Maximum size (Maximum size = Initial size )

Startup and Recovery

Logon user

Check
Check
Complete memory dump
Check

y_admin
y_admin
y_admin
y_admin
y_admin
y_admin
y_admin
y_admin

Quality

Windows setting sheetWindows 7 SP1/Server2008R2 SP1/ for CENTUM VP R5.01


Customer Name:

SIC-33Q6-004E R4

JOB NAMEDOMAINSTATION

Setting Items
The confirmation of the wearing positions such as attached cards
(Confirm it before power supply injection by all means!!
Window Color and
Control Panel
Personalization
Appearance

Correct Setting

Screen to confirm

Desktop Background

Choose the option of


[Open classic
appearance properties
for more color options]

Choose [Windows 7] for [Color scheme](Windows 7 only)

y_admin

Location

Choose [Solid Colors] for [Location] and [Black] color

y_admin

Choose (None)

y_admin

Choose to Display
Normal Display 1280 x 1024 , 1600 x 1200
Wide Display 1280 x 800,1440 x 900,1680 x 1050,1920 x 1200

y_admin

Highest (32 bit)

y_admin

Choose to Display
Normal Display 1280 x 1024 , 1600 x 1200
Wide Display 1280 x 800,1440 x 900,1680 x 1050,1920 x 1200

y_admin

Highest (32 bit)

y_admin

*In the case of V2

CRT1 is the lower screen

y_admin
y_admin

Hard disk

Choose [High performance]


Set Never for [Turn off hard disk after]

Screen Saver
Display Settings

Primary Display

*Secondary Display

Preferred plans

Power Options

Hibernate afterSetting : Never


Sleep
Allow wake timers Setting : Disable
Power buttons and lid Power button action Setting : Shut down
Display

Windows Defender
Network

Logon user

Set Never for [Turn off display after]

Administrator options
Clear the check box [Use Windows Defender] (Server2008 is No Setting)
[Tools]-Options]
*When Set Network Location Dialog Box is Displayed, click [Public] on the dialog box.
Change Local Area
Onboard
"Ethernet"
Connection
Name
PCI-E x1
"Ethernet2"

*V-net
Vnet
VnetIP
When not use it, disable it OpenComm

y_admin
y_admin
y_admin
y_admin
y_admin
y_admin
y_admin
y_admin

"Vnet"

y_admin

"Vnet"

y_admin

"VnetIP"

y_admin

Quality

Windows setting sheetWindows 7 SP1/Server2008R2 SP1/ for CENTUM VP R5.01


Customer Name:

SIC-33Q6-004E R4

JOB NAMEDOMAINSTATION

Setting Items
The confirmationNetwork
of the wearing
Propertypositions such as attached cards

Correct Setting

Screen to confirm

TCP/IP

172.17.dd.ss

y_admin

Protocol

Deselect [Yokogawa Vnet Protocol] and [Internet Protocol Version 6


(TCP/IPv6)].

y_admin

172.18.dd.ss

y_admin

Deselect [Yokogawa Vnet Protocol] and [Internet Protocol Version 6


(TCP/IPv6)].

y_admin

(Confirm it before power supply injection by all means!!

Ethernet

TCP/IP
Ethernet2
When not use it, disable it Protocol
TCP/IP
Vnet/VnetIP

Logon user

Protocol

172.16.dd.ss
Deselect all the items except [Yokogawa Vnet Protocol] and [Internet
Protocol version 4 (TCP/IPv4)].

y_admin
y_admin

IP address192.168.<128 + DOMAIN No>.<129 + STATION No>


VnetIPOpen
When not use it, disable it

Network Connections
[Advanced]

Disabling the alerts


Date and Time

Setting Password
Disk Defrag

[Advanced Settings]
Adapters and Bindings
Notification Area Icons
Date and Time

Password must meet


complexity requirements
setting :{Disabled}

TCP/IP

subnet mask255.255.255.0
Default gateway VnetIP system with multiple Domain, it will be IP

y_admin

address of L3SW Switch.


Protocol

Deselect [Yokogawa Vnet Protocol] and [Internet Protocol Version 6


(TCP/IPv6)].

y_admin

Connections (Vnet)

EthernetEthernet2Vnet

y_admin

Action Center]

Vnet/IP OpenVnetIP Vnet


Vnet/IP Open and Ethernet EthernetVnetIPVnet
Hide icon and notifications

Network

Only show notifications

y_admin

Date and Time

Check correct setting

y_admin

Time zone

Check correct setting

y_admin

Internet Time

Uncheck the [Synchronize with an Internet time server]

y_admin

Therefore, the password complexity is required. So that if you set a password


does not satisfy the complexity requirement, the password will not be
accepted(Windows Server 2008 only)

y_admin

Connections (VnetIP)

[Start] Menu - [All Programs] - [Accessories] - [System Tools] - [Disk Defragmenter] Uncheck the option of [Run on a schedule (recommended)]

y_admin
y_admin

y_admin

Quality

Windows setting sheetWindows 7 SP1/Server2008R2 SP1/ for CENTUM VP R5.01


Customer Name:

SIC-33Q6-004E R4

JOB NAMEDOMAINSTATION

Setting Items
The confirmationInstall
of the wearing positions such as attached cards
Excel

Correct Setting

Screen to confirm

When you install Excel, also install the following.

(Confirm it before power supply injection by all means!!

Office Shared Featuresmust install Visual Basic for Applications


VBA ProjectsDigital Certificate
Check for activation status.

Installation
Certification of Excel

Select the following radio buttons of [Macro Settings] items [Enable all macros
(not recommended, potentially dangerous code can run)]
[Developer Macro Settings], select the checkbox for [Trust access to the VBA
project object model].

Microsoft Excel Macro


Security setting

[Microsoft Office] button[Excel Options][Trust


Center][Macro Settings]

Security
Updates

Microsoft Security Updates

http://www.yokogawa.com/vps/update/msup/vps-msup-en.htm
Download and install the required patches from CENTUM of the left web site.

CENTUM

Install

Enable touch panel

LPCKIT

Installation

Logon user
y_admin
y_admin
y_admin
user
user
y_admin

1TPOnly for lower section specifications

y_admin

2TPOnly for upper section specifications

y_admin

CENTUM installation

CENTUM VP
Install after connecting the hardware to one of the PORT. Disconnect and
OPKB keyboard drivercase without AIP261
connect it to another port and check whether it recognizes.
NET Framework 3.5
Server 2008 R2 only You must enable .NET Framework 3.5.1 as it is disabled by default
IT Security Settings
Set an appropriate model.

y_admin

Distributing and Activating Licenses

y_admin

Apply patches

Check OK status in License manager

http://globalcyber.jp.ykgw.net/qa/sps/VP_ReleaseNote.htm
Check the ReleaseNote, to apply some required patches.

y_admin
y_admin
y_admin
y_admin

Quality

Windows setting sheetWindows 7 SP1/Server2008R2 SP1/ for CENTUM VP R5.01


Customer Name:

Setting Items
The confirmation of the wearing positions such
as attached
Password
*1 cards

Correct Setting

Screen to confirm

Changing password

Yokogawa1 -> CENTUM

[Visual Effects]

Windows7check the option of [Let Windows choose whats best for my


computer].
Server2008check the option of{Adjust for best performance}

(Confirm it before power supply injection by all means!!

Setting of CENTUM user

Advanced system settings

y_admin
user
user

Choose [Windows Aero] for [Color scheme]

user

Desktop Background

Location

Choose [Solid Colors] for [Location] and [Black] color

user

Screen saver

(none)

user

Re-login after cancelling Welcome Center.


Choose to Display
Normal Display 1280 x 1024 , 1600 x 1200
Wide Display 1280 x 800,1440 x 900,1680 x 1050,1920 x 1200
Highest (32 bit)
Choose to Display
Normal Display 1280 x 1024 , 1600 x 1200
Wide Display 1280 x 800,1440 x 900,1680 x 1050,1920 x 1200
Highest (32 bit)

user

CRT1 is the lower section.


Hide icon and notifications

user

Only show notifications

user

Display Settings

Primary Display

*Secondary Display

*In the case of V2


Disabling the alerts

Logon user

Choose the option of


[Open classic
Window Color and Appearance
appearance properties
for more color options]

Welcome center

Notification Area Icons

Action Center]

Network
License
Agent.TaskTray
Operation check of CENTUM VPstart of the operation
monitor screen
When it is with an on-line manual

Control Panel

SIC-33Q6-004E R4

JOB NAMEDOMAINSTATION

Microsoft Excel Macro


Security setting

[Microsoft Office] button[Excel Options][Trust


Center][Macro Settings]

Regarding Maximum
Password Age

[Control Panel]-[Administrative Tools]-[Computer


Management]-[System Tools], choose [Local Users
and Groups].-[CENTUM Properties]. *1

Hide icon and notifications (set it after installation)

user
user
user
user
user

user

Confirm that it can start

user

Confirm by opening the IM.


Select the following radio buttons of [Macro Settings] items [Enable all macros
(not recommended, potentially dangerous code can run)]
[Developer Macro Settings], select the checkbox for [Trust access to the VBA
project object model].

user

Check [Password never expires]

*1 IT Security Settings is Legacy Model

user
user

y_admin

Quality