3.

2 Tabla de datos experimentales

Presin de operacin
Presin en el hervidor
Presin de entrada al
condensador

ALIMENTACIN
DESTILACIN
RESIDUO
PLATO 1
PLATO 4
PLATO 5
PLATO 7
PLATO 8
PLATO 9
PLATO 10
PLATO 11

TEMP
(C)
25
55
22
41
44
38
32
43
43
46
37

0.4 kgf/cm
0.55 kgf/cm
4.5 lb/in

DENSIDAD
(G/CM)
0.96
0.791
0.959
-

3.3 Clculos

=1.265
kg
1.02 2
cm
kgf
kgf
kg
||=0.4
+ 0.79 2 =1.29 2
2
cm
cm
cm
P
1

o Para grfica ideal


Ecuacin de Antoine

||=1.27

Metan
ol
Agua

A
B
C
5.202 1580.0 239.5
77
8
5.1156 1687.5 230.1

VOLUMEN
(ML)
250
250
100
-

NDICE DE
REFRACCIN
1.335
1.3385
1.3275
1.33
1.33
1.332
1.335
1.335
1.335
1.335

XW%
24
99
23

37

*Despejamos T (t ebullicin) de la ecuacin para ambas soluciones.


T=

B
C
Alog P

Teb (C)
70.3
106.42

Metanol
Agua

*Proponemos temperaturas entre las temperaturas de ebullicin de la


mezcla y sacamos sus presiones parciales.
P i=10

B
C+T

Xmet=

PP agua
P met P agua

Ymet=

P metXmet
P

Temp
(C)
70.27
83
73.77
83
77.27
83
80.77
83
84.27
83
87.77
83
91.27
83

P Met

P
Agua

1.26
50

0.31
54

1.44
24

0.36

1.63
34

91
2.10

04

28

63

43

0.43
34

0.75
91

02

0.54
32

0.67
49

0.27
47

82

28
0.36

0.73

0.30

0.83

0.45

0.64

2.66

68

68

0.16
48

0.89

0.56

0.56

2.37

0.95

0.69

66

10

0.0

23

18

82

20

0.83

0.48

Xagua

1.00
00

52
0.42

1.85

Ymet

1.00
00

61

98

Xmet

0.63
98

0.57
90

0.72
53

94.77
83
98.27
83
106.42
53

2.99

0.83

18

0.19

64
3.34

0.95

90
60

0.86

76
0.00

50

11
0.34

13
1.26

0.80

03
0.13

00
4.31

0.47

89

87
0.00

00

1.00

00

00

Graficamos

T vs XY
106
102
98
94
90
Temperatura

86
82
78
74
70

0.1

0.2

0.3

0.4

0.5
X, Y

0.6

0.7

0.8

0.9

X vs Y
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

Para grfica No Ideal


Se repiten los pasos de la grfica ideal hasta las presiones
parciales.
Se calcula el valor de los coeficientes de actividad A y B con las
ecuaciones de Van Laar. Los parmetros de interaccin son:
A 12

A 21

0.8041

0.5619

Como no se conoce el valor de las concentraciones, es necesario


suponer los valores de X A para cada temperatura considerada

A= A 12(1+

A12 X A
)
A21 (1 X A )

A
1X
2

1+ A 21 ( A X )
12
A
A 21
B=

Se calcula el valor de X A

Xa=

PP b
P aP b

Si el resultado es igual que el de la concentracin supuesta para los


coeficientes significa que la suposicin es la correcta, de lo contrario
es necesario proponer una nueva.
Una vez hallado X A

Ya=

calcular

YA

P a AXa
P

TEMP
70.3
73.6
76.9
80.2
83.5
86.8
90.1

P1
1.26
60
1.43
29
1.61
75
1.82
13
2.04
59
2.29
27
2.56

P2
0.31
57
0.36
34
0.41
69
0.47
69
0.54
41
0.61
90
0.70

XSUP
1.00
10
0.78
57
0.59
52
0.43
50
0.31
10
0.22
03
0.15

A
1.000
0
1.020
8
1.087
0
1.199
6
1.345
6
1.503
4
1.657

B
1.755
4
1.486
5
1.294
6
1.167
0
1.090
4
1.047
7
1.024

XA
0.998
5
0.785
7
0.595
2
0.435
1
0.311
0
0.220
3
0.154

YA
1.001
8
0.908
5
0.827
3
0.751
3
0.676
8
0.600
3
0.518

35
93.4

23
2.86

0.79

00
96.7

48
3.18

0.89

38
100

73
3.53

1.01

70
103.3

05
3.92

1.13

13
106.32
53

45
0.10
60
0.06
93
0.04
06
0.01
77
0.00
05

53
4.30

1.26

29

07

5
1.799
9
1.928
4
2.044
0
2.147
2
2.232
1

4
1.011
9
1.005
2
1.001
8
1.000
4
1.000
0

6
0.106
1
0.069
3
0.040
6
0.017
8
0.000
5

Graficamos

Y,X
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

9
0.431
3
0.336
3
0.232
0
0.117
8
0.003
8

T, XY
106
103
100
97
94
91
Temperatura

88
85
82
79
76
73
70

0.1

0.2

0.3

0.4

0.5
X, Y

Pasamos fraccin peso a fraccin mol


0.2 4
32
Z mol =
=0.15
0.2 4 0.7 6
+
32
18
0.99
32
X D=
=0.9 82
0.99 0.01
+
32
18
0.23
32
X B=
=0. 143
0.23 0.77
+
32
18

0.6

0.7

0.8

0.9

Para sistema No Ideal


Calculamos Entalpias
T roco
102 C
T burbuja 89C

(kcal/km
ol)
Metan
8415
ol
Agua
9718

Cp
(Kcal/kmol
C)
19.38
18

Cpm=19.38 ( 0.15 )+18 ( 0.85 ) =18.2

kcal
kmol C

m=8415 ( 0.15 ) +9718 ( 0.85 ) =9522.55

kcal
kmol

Hv=Cpmtr + m

Hv= 18.2

kcal
kcal
kcal
( 102 C ) +9522.55
=11379
kmol C
kmol
kmol

h L=Cpmtb=18.2

kcal
kcal
89 C=1619.8
kmol C
kmol

h F=Cpmtalim=18.2

HvhF
q=
=
HvhL

kcal
kcal
25 C=455
Kmol C
kmol

kcal
kmol
=1.12<Liq
kcal
( 113791619.8 )
kmol

(11379455 )

y=

q
z
x
q1
q1

Y
0
0.9

X
0.13
0.23

*De grfica
n=

NET 1
61
100=
100=38.4
NPR
13

XD
=0. 42
Rm+ 1

*Despejamos Rm
Rm=

xD
0.982
1=
1=1. 338
0.42
0.42

Rptimo =1.5 Rm=1.5 (1.338 )=2. 007


Rp timo=1.5 Rm=1.2 (1.338 )=1. 605

*Plato 8
0.08
32
X p 7=
=0. 046
0.08 0.92
+
32
18

Del diagrama t 8=9 9 C


5.20277

Pmet 8 =10

1580.08
239.5+ 9 9

5.11564

Pagua8 =10

=3.3 7

1687.537
230.17+9 9

=0.97

X met 8=

PP b
1.2650.97
=
=0. 123
P aP b 3.370.97

Y met 8=

P aXa 3.37 (0.123)


=
=0.327
P
1.265

De grficas Y*=0.29 y X*=0.05

*Plato 7
0.96
32
X p 7=
=0.93
0.96 0.04
+
32
18

Del diagrama t7 =72 C

Pmet 7 =10

5.20277

Pagua7 =10

1580.08
239.5+72

5.11564

=1.35

1687.537
230.17+72

=0.34

X met 7=

PP b
1.2650.34
=
=0. 915
P aP b 1.350.3 4

Y met 7 =

P aXa 1.35 (0.915)


=
=0.976
P
1.265

De grfica Y*=0.96 X*=0.94

mv =

0.9760.327
=.968
0.960.29

mL =

0.9150.12
=0. 893
0.940.05

Para sistema Ideal


Calculamos Entalpias
T roco
104 C
T burbuja 96C

(kcal/km
ol)
Metan
8415
ol
Agua
9718

Cp
(Kcal/kmol
C)
19.38
18

Cpm=19.38 (0.15)+18 ( 0.85 )=18.2

k cal
kmol C

m=8415 ( 0.15 ) +9718 ( 0.85 ) =9522.55

kcal
kmol

Hv=Cpmtr + m

Hv= 18.2

kcal
kcal
kcal
( 104 C ) +9522.55
=11415.4
kmol C
kmol
kmol

h L=Cpmtb=18.2

kcal
kcal
96 C=1747.2
kmol C
kmol

h F=Cpmtalim=18.2

kcal
kcal
25 C=455
Kmol C
kmol

kcal
HvhF
kmol
q=
=
=1.13<Liq
HvhL
kcal
( 11415.41747.2 )
kmol

( 11415.4455 )

y=

q
z
x
q1
q1

Y
0
0.9

X
0.13
0.23

*De grfica
n=

NET 1
61
100=
100=38.4
NPR
13

XD
=0.3 2
Rm+ 1

*Despejamos Rm
Rm=

xD
0.982
1=
1=2.07
0.3 2
0.3 2

Rptimo =1.5 Rm=1.5 (2.07 )=3.15


Rptimo =1.5 Rm=1.2 ( 2.07 )=2.48

*Plato 7
0.96
32
X p 8=
=0.93
0.96 0.04
+
32
18

Del diagrama t7 =74 C


5.20277

Pmet 7 =10

Pagua7 =10

1580.08
239.5+74

5.11564

=1.45

1687.537
230.17+74

=0.369

X met 7=

PP b
1.2650.369
=
=0.828
P aP b 1.450.369

Y met 7 =

P aXa 1.45 (.828)


=
=0.949
P
1.265

De grficas Y*=0.96 X*=0.93

*Plato 8
0.08
32
X p 7=
=0.046
0.08 0.92
+
32
18

Del diagrama t 8=104.5 C


Pmet 8 =10

5.20277

Pagua8 =10

1580.08
239.5+104.5

5.11564

=4.06

1687.537
230.17+104.5

=1.183

X met 8=

PP b
1.2651.183
=
=0. 028
P aP b 4.061.183

Y met 8=

P aXa 4.06(0.028)
=
=0. 0898
P
1.265

De grficas Y*=0.12 X* =0.046

mv =

0.9490.0898
=1.02
0.960.12

mL =

0.8280.028
=0.905
0.930.046

TABLA DE RESULTADOS
o No Ideal
Alimentaci
n
Destilado
Plato 7
Plato 8
Residuo

Xmol
0.15

X*
-

Y*
-

X
-

0.982
0.172
2
0.13
0.143

0.93

0.96

0.915 0.976

0.046
-

0.29
-

0.129 0.327
-

Hv(kcal/kmol)
Hl(kcal/kmol)
Hf(kcal/kmol)
q

R ptimo (1.5Rm)
R ptimo (1.2Rm)
mv
mL

Y
-

11379
1619.8
455
1.12
38.4%
2.007
1.605
0.968
0.893

o Ideal
Xmol
0.15

X*
-

Y*
-

X
-

Y
-

0.93

0.96

0.828

0.949

Plato 8

0.982
0.172
2
0.13

0.046

0.12

0.028

Residuo

0.143

0.089
8
-

Alimentaci
n
Destilado
Plato 7

Hv(kcal/kmol)
Hl(kcal/kmol)
Hf(kcal/kmol)
q

11415.4
1747.2
455
1.13


R ptimo (1.5Rm)
R ptimo (1.2Rm)
mv
mL

38.4%
3.15
No
2.48ideal
1.02
0.905

X,Y
1

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.1

0.2

0.3

0.4

0.5

0.6

0.7

105

100

95

90
Temperatura
85

80

75

70

0.1

0.2

0.3

0.4

0.5
X, Y

0.6

0.7

0.8

XY
1

Ide
al

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

106
104
102
100
98
96
94
92
90
Temperatura

88
86
84
82
80
78
76
74
72
70

0.1

0.2

0.3

0.4

0.5
X, Y

0.6

0.7

0.8

CONCLUSION

De acuerdo a esta practica pudimos ver el comportamiento de


una operacin en un destilador cuando esta a reflujo total. Como
se observa en las graficas del sistema ideal y no ideal podemos
ver como la presin a la que se trabaje si influye demasiado en la
construccin de los diagramas por eso se debe Tener mucho
cuidado en la toma de los datos ya que afecta principalmente a
los puntos de ebullicin de las sustancias.
Como se puede ver en la eficiencia de los platos cuando tenemos
un sistema ideal ser mayor su eficiencia a comparacin del no
ideal debido a las condiciones de trabajo y a la correccin con las
constantes de mrgales que son mtodos aproximados, pero en
el caso de los platos tericos dio el mismo resultado de 6 platos
esto debido al reflujo que dio diferente en ambos casos.
La eficiencia de la columna nos dio de 38.4% para ambos casos
ya que el numero de platos fue el mismo para ambos caso lo cual
no significa que las condiciones de operacin sern las mismas.
Cabe mencionar que solo se hizo la comparacin con el sistema
ideal ya que en la realidad sera muy difcil que presentara ese
comportamiento la mezcla.
Los errores de toma de datos se pueden ver reflejados en las
temperaturas y en los ndices de refraccin, ya que se ve observa
cmo no llevan una tendencia los datos por lo que se puede
deber al refractmetro o al mal manejo de las muestras.

REFERENCIA Y BIBLIOGRAFA