You are on page 1of 4

TOPWELD

H01N2-D

<HAR>

The special cable for welding


a Applications

The Topweld H01N2-D cable has been specially designed


for transmitting high currents between the welding generator
the welding tool easier and also keep knots from forming in
the cable that could cause the internal conductor to break.
It can also be used in automatic welding machines, transport
belts, and production or assembly lines, for example in
automobile assembly lines.

b Characteristics
1.- Maximum flexibility: The use of flexible copper conductors (Cl. D) as well as vulcanised rubber
sheath gives the cable maximum flexibility which will prevent the conductor from breaking.
2.- Resistance to chemical products: Vulcanised rubber sheath is the most effective way of
protecting against atack of chemical products, like hydrocarbon and mineral oils.
3.- Resistant to ozone and ultraviolet rays.
4.- Weather resistance: The properties of the vulcanised rubber sheath on the Topweld H01N2D cables allows a permanent use outdoors.
5.- Fire proof properties: The no flame propagation properties of the Topweld H01N2-D contribute
towards the overall safety of the installation.

Applications

Heavy Duty

welding

No flame
propagation

Topweld H01N2-D 37

Topweld
H01N2-D

and the electrode. The high degree of flexibility makes using

c Technical data
The table shows diameter, weight, current-carrying capacity and voltage drop detailed for each
cable.
Current-carrying capacities shown in the table are calculated according to HD 516 and for the
following conditions:
- Open air installation: It is supposed a single full service cycle with a duration of 5 minutes and
ambient temperature of 25 C, with different loading times.
Voltage drop, in V per 100 A and 100 m, it is calculated at CC and to the maximum conductor
temperature.

Environmental conditions

No flame
propagation:
IEC 60332-1
EN50265

38 Topweld H01N2-D

Impact resistance:
AG 2
Medium impact

Outdoor installation:
permanent

Water resistance :
AD 3
Aspersion

Chemical & oil attack


resistance: good

Dimensions

Cross -section
mm2
1 x 10
1 x 16
1 x 25
1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
1 x 150
1 x 185

Maximum current for a 5 minute period


100 %
100
135
180
225
285
355
430
500
580
665

85 %

60 %

103
145
195
245
305
380
470
540
630
720

108
175
230
290
365
460
560
650
750
860

35 %
122
230
300
375
480
600
730
850
980
1120

Voltage drop
V
2,450
1,560
0,998
0,709
0,493
0,348
0,264
0,206
0,166
0,136

Diameter
f
mm
8,0
9,0
10,2
11,5
13,4
15,5
17,6
19,6
21,7
23,9

Approx. weight
kg/km
138
196
279
372
520
724
947
1197
1493
1806

*Top Cable reserves the right to carry out any modification whatsoever without giving previous notice.

Topweld H01N2-D 39

d Design
- Conductor: Flexible electrolytic annealed copper conductor, class D according to HD 22.6.
- Separator: Polyester tape.
- Sheath: Thermosetting rubber sheath, black color, type EM5 according to HD 22.

According to
HD 22
UNE21027

40 Topweld H01N2-D

4
52

1
3
52

Characteristics

Flexible conductor
class D

Rated Voltage :
100/100 V

Maximum service
temperature: 85C

Minimum bending
radius:
4 x f cable

Meter by meter
marking

You might also like